Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
45871-Z
'075 . g_ 9. 210 0 GENERAL NOTES 0 PROPOSED 1. ALL WORK under this Application shall comply with theMAINTAIN EXISTING CONCRETE PATI t I!2020 International Residential Code of New York Sate, (IBC 2020). 2. NO WORK shall proceed until such time as the TOWN OF SOUTHOLD BUILDING DEPARTMENT has issued a Building MASTER BATHROOM ADDITION TO AN EXISTING Permit and a Plumbing Permit. J A M Es T H O M A S MARTIN O 3. The GENERAL CONTRACTOR certifies to the &'vner that he is a licensed Contractor in the State of New York; Suffolk A R C H I T E C T P. C. County and fully insured as required by the TOWN OF SOUTHOLD BUILDING DEPARTMENT. 75 Nassau Avenue 4. The PLUMBING CONTRACTOR certifies to the Owner that Manhasset, New York 11030 SINGLE FAMILY DWELLING he is a fully licensed Contractor in the State of New York, 5 1 6 . 7 6 7 . 7 8 8 8 - FAX 5 1 6 . 7 6 7 . 3986 Suffolk County and fully insured as required by the TOWN OF Email: info@jtmarchitect•com www.jtmarchit- t.com SOUTHOLD BUILDING DEPARTMENT. FILE DATE TO BY 5. The ELECTRICAL CONTRACTOR certifies to the Owner that he is a fully licensed Contractor in the State of New York, 12.14.20 Three (3) Sets of Drawings J.T.M. Suffolk County and fully insured as required by the TOWN OF issued for filing with the SOUTHOLD BUILDING DEPARTMENT. TOWN OF SOUTHOLD PUuL E11-11113 E I \ Lz, DENCE 6 The GENERAL CONTRACTOR is to field measure the existing conditions affected by this proposed wor'; to confirm all dimensions prior to proceeding. 7. The GENERAL CONTRACTOR is to inform James Thomas Martino, Architect of any discrepancies between the field conditions and the dimensions indicated on these drawings prior to proceeding. 8. The GENERAL CONTRACTOR is responsible tc) coordinate the work performed by all trades, including but n,)t limited to: his plumbing, mechanical and electrical sub-contractor's and any other trades that may affect this project. 9. The GENERAL CONTRACTOR is responsible to coordinate all locations where wood blocking and/or plywood backing TOWN OF SOUTHOLD ZONING ANALYSIS INFORMATION may be necessary for a proper installation. ADDRESS: 3600 S HARBOR ROAD,SOUTHOLD, NEW YORK 11791 10. The GENERAL CONTRACTOR is to confirm all finishes West Side of S Harbor Road. with the property owner prior to ordering and/or installing any S.C.T.M. 1000-75-8-3.1 finish materials. Code Section Zoning District Classification: R-80 Total Lot Area: 17,424.00 sq.ft. 11. The GENERAL CONTRACTOR and his Electrical Sub-Contractor are responsible for coordination of all electrical devices including but not limited to switches, gfci outlets, PERMITTED/REQUIRED EXISTING PROPOSED COMPLIANCE recessed lighting, surface mounted lightning, jun tion boxes, A etc. LOT SIZE. / o Minimum Lot Size: 80,000 sq.ft. 17,424.00 sq.ft. Existing, No Change Pre-Existing 12. The GENERAL CONTRACTOR and his PLUMBING / SUB-CONTRACTOR are responsible for the coordination of LOT WIDTH. the plumbing fixtures, including but not limited to sinks, NO. DATE REVISIONS BY Minimum Lot Width: 175.00 ft. 100.00 ft. Existing, No Change Pre-Existing H faucets, toilet, soaking tub, shower controls, shower drain, etc. LOT DEPTH. O 13. The GENERAL CONTRACTOR is responsible to verify with C his PLUMBING SUB-CONTRACTOR the size of the existing Minimum Lot Depth: 250.00 ft. 204.23 ft. Existing, No Change Pre-Existing Hot Water Heater(HWH) and whether the existing HWH will be / = of sufficient capacity to support the additiona hot water FRONT YARD. demand for the Master Bathroom. If deemed insufficient, the - Minimum Front Yard: 60.00 ff. 20.50 ft. Existing, No Change Pre-Existing N GENERAL CONTRACTOR will submit to the Owne, a separate O = price quote to remove and replace the existing HWH with a P SIDE YARD. O 0 > new one of sufficient capacity. Minimum Side Yard: 20.00 ft. Side Yard 1: 6.18 ft. Existing, No Change Pre-Existing / . O_ W 14. The ELECTRICAL SUB-CONTRACTOR is responsible for Side Yard 2: 29.99 ft. O 0 03 obtaining an Electrical ROUGHING Inspection approval from Nb - O an independent Fire-Underwriters Electrical Inspector. BOTH SIDE YARDS. 03� n� �(z��E rn W Minimum Both Side Yards: 45.00 ft. 36.17 ft. Existing, No Change Pre-Existing 11�\GO� 15. The ELECTRICAL SUB-CONTRACTOR is responsible for ty� obtaining a FINAL Electrical Inspection and an Underwriter's v W Electrical Certificate for the new work approval by an REAR YARD. / N Q independent Fire-Underwriter's Electrical Inspector Minimum Rear Yard: 75.00 ft. 74.69 ft. Existing, No Change Pre-Existing / o D 16. The GENERAL CONTRACTOR shall submit to the Owner's LIVABLE FLOOR AREA. o the Original (green) FINAL Underwriters Electrical Certificate Minimum Floor Area: 850.00 sq.ft. 1,668.65 sq.ft. 1,774.25 sq.ft. Yes, Complies / for submission to the Inc. village of Floral Park Building Department, LOT COVERAGE. / / / ONO ' 17. The GENERAL CONTRACTOR and his Sub-Contractor(s) Maximum Lot Coverage: 20% (3,484.80 sq.ft.) 9.58% (1,668.65 sq. ft.) 10.18% (1,774.25 sq.ft.) Yes, Complies shall make any and all changes to their work as deemed \,5`b necessary by the TOWN OF SOUTHOLD BUILDING BUILDING HEIGHT. <(, INSPECTOR at no additional cost to the owner. Maximum Building Height: 35.00 ft. ± 13 ft. ± 13 ft. Yes, Complies o�� O� / 18. All New Conventional Wood Framing Members shall be NUMBER OF STORIES. �� �% OP STO shall be Douglas Fir-Larch #2 minimum, NO EXCEPTIONS. Maximum No. of Stories: 2 J Stories 1 Story Existing, No Change Yes, Complies 19. Written dimensions shall take precedence over scaled es \g• dimensions and detailed drawings over smaller scale drawings. CALCULATIONS: / P\���p��O 2� 20. The GENERAL CONTRACTOR shall verify & be responsible for all existing dimensions & conditions on the job. The Architect's TTED ice t be of any MAXIMUM ting SingleRFalmily DwellingO Footprint = 1,668.65 sq.ft. / / C,O�G ccofnditionssnd indic ated l d don these drawings.deviations of the dimensions and INTELLECTUAL PROPERY ACT Of 2007 - Proposed Addition = 105.60 sq. ft. G��\ 000010 OWNERSHIP OF DOCUMENTS: All drawings, plans Total Lot Coverage = 1,774.25 sq.ft. \\ 21. The GENERAL CONTRACTOR shall be responsible for bracing QP G�\' & protecting against wind &storm damage, breakage, collapse, sketches, models, renderings, Specifications & othe Maximum Permitted Lot Coverage = 3,484.80 sq.ft., under by 1,710.55 sq.ft therefore Complies I- IR OS�� �O��y S distortion and mis-alignment of all areas affected by this GROSS FLOOR AREA CALCULATIONS. documents, including those in electronic format (pdf), prepared / Q O � the Architect, JTMA, as the author & owner o these �G alteration. b pp JTMA are Instruments of Service & are the sole property of Q�QO\�\� � ��. Existing Single Family Dwelling (1st Floor) = 1,668.65 sq.ft. P \�. 6 �5 22.The GENERAL CONTRACTOR shall be responsible for recording Instruments Of Service holds all Common law, statutory & othe Proposed Addition = 105.60 sq.ft. N '1 accurate "AS-BUILT" DOCUMENTS of any changes made during rY Total Existing Gross Floor Area = 1,774.25 sq.ft. / the course of this Alteration. rights including copyrights in the Instruments of Service. Minimum Permitted Gross Floor Area = 850.00 sq.ft., over by 924.25 sq.ft.therefore Complies N / / 23. The GENERAL CONTRACTOR will be solely responsible for the restoration, replacement and/or repair of any and all areas that DRAWN BY:/ DATE:were damaged by his own work force and any of his D.M.S. 11.12.20 I 0000 Sub Contractors during this construction. c.� �, cHK'D BY: J.T.M. SCALE: AS NOTED EDRAWING INDEX MATERIAL SYMBOLS � PROJECT: 20- 2025 SHEET SHEET INFORMATION i�ii���i�� EARTH BRICK � WOOD BLOCKINGPROJECT: NO. O� MAINTAIN EXISTING CONCRETE PATIO & GENERAL STONE FILL ® ALUMINUM PLYWOOD Z �o Ikb PROPOSED MASTER BATHROOM ADDITION TO AN 000 -._-.-------._-__ ..--------_------------------.-----. ..._._.------------.-.-__----_._----------_____-- 5 p0' EXISTING SINGLE FAMILY DWELLING G-0 SITE PLAN,ZONING ANALYSIS&NOTES ® ® O S CONCRETE STEEL GLASS 00 _ �uG �i �sc RESIDENCE 0 � A-1 EXISTING&PROPOSED PLANS,CELLAR&FIRST FLOOR PLANS&WINDOW SCHEDULE """" ' SAND WOOD FINISH ® BATT INSULATION 0 W b �,-:'.... F. ° A•-2 ENLARGED BATHROOM PLAN,ELEC.PLAN,INT.ELEVATIONS&PLUMBING RISER DIA. CONC. BILK. SOUTH HARBOR ROADK. ® WOOD ROUGH RIGID INSULATION � •,00,, o0 A'AASECTIONS&EXTERIOR ELEVATI TOWN OF SOUTHOLD ONS � b�y SUFFOLK COUNTY, NEW YORK 11971 SYMBOL LIST 34' S.C.T.M. # 1000 - 75 - 8 - 3.1 DRAWING: DETAIL NUMBER '� /� �• REVISION# DRAWING NUMBER SITE PLAN, ZONING SECTION NUMBERkty DRAWING NUMBER If# # INTERIOR ELEVATION / ANALYSIS & NOTES SPOT ELEVATION PROPOSED SITE PLAN + SEAL: A __� DRAWING: SCALE:T = 1-o D Rti Q E C // acnns fi\. NOTE: ALL METES&BOUNDS INFORMATION HAS BEEN TAKEN FROM A SURVEY PREPARED BY: • } d1 PAUL BARYLSKI LAND SURVEYING PATCHOGUE,NEW YORK 11772 41 4- 1, - PHONE:(631)294-6985 :1 0 FAX:(631)627-3186 E _may Q EMAIL:PAULBARYLSKI@YAHOO.COM yT o16453 y0 SURVEY LAST DATED FEBRUARY 3,2017 „yy F OF NEB S.C.T.M.# 1000075000800003001 DWG: 00 OF: 00 COPYRIGHT 2020 (c)by James Thomas Martino, Architect, P.C. _____________ __ FRAMING NOTES +i Based upon Table R502.3.1 (1)- 26'-a is-s i3'-112 FLOOR JOIST SPANS for Common Lumber Species All 1;1 RESIDENTIAL SLEEPING AREAS(above) celar unexcay. Lwind.r, Live Load: 40 psf - _ -win 11 ow Dead Load: 20 psf - w II Joist Spacing: 12"o.c. Species &Grade: Douglas Fir-Larch #2 J A M Es T H O M A S M A R T I N O Joist Size: 2"x 8"Wood Ceiling Joists Maximum Permitted Joist Span @ 12"o.c. = 14'-9" S.D. S.D. S.D. Actual Maximum Joist Span= 1 l'-4";therefore, o.k. A R CH I T E C T, P. C. Note:Contractor to provide solid wood blocking at mid-span 75 Nassau Avenue ;4r :::%z I Manhasset, New York 11030 existing Lowe 516 . 767 . 7888 o FAX 51 6 . 767 . 3986 steps up tog de �� �� Based upon Table R802.4(2)- / Email: info@jtmarchitect.com www.jtmarchitect.com CEILING JOIST SPANS for Common Lumber Species S.D. — UNINHABITABLE ATTICS WITH LIMITED STORAGE AREAS(above) FILE DATE TO BY Live Load: 20 psf s.D. c e I I a r s.D. master Dead Load: 10 psf 12.14.20 Three (3) Sets of Drawings J.T.M. bedroom Joist Spacing: 16"o.c. issued for filing with the b Species&Grade: Douglas Fir-Larch #2 TOWN OF SOUTHOLD ° Joist Size: 2"x 8"Wood Ceiling Joists Maximum Permitted Joist Span: 16'-6" bedroom o Actual Maximum Joist Span: 13'-3",therefore,o.k. o U v b u 3 3 3 Note:Contractor to provide solid wood blocking at mid-span Based upon Table R802.5.1 (1) - ROOF RAFTER SPANS for Common Lumber Species L] CEILING NOT ATTACHED TO RAFTERS i Roof Live Load: 20 psf �cell.r c II rRoof Dead Load: 20 psf w' elw Joist Spacing: 16"o.c. Species & Grade: Douglas Fir- Larch #2 12-2° 2-° Joist Size: 2"x 8" Roof Rafters Maximum Permitted Joist Span: 16'- 0" Actual Greatest Joist Span: 13' - 6", therefore, o.k. EXISTING CELLAR FLOOR PLAN EXISTING FIRST FLOOR PLAN xti Xti SCALE: 1/4" = 1'-0" SCALE: 1/4" = V-01' GENERAL NOTES SC EXISTING surface mounted,combination hard-wired smoke detector&carbon monoxide SC EXISTING surface mounted,combination hard-wired smoke detector&carbon monoxide detector as per the requirements of Section R313.1 +R313.4 of the Residential Code of New York detector as per the requirements of Section R313.1 +R313.4 of the Residential Code of New York 1. ALL WOOD FRAMING WORK under this Application shall State. State. comply with Chapters 5, Floors; Chapter 6, Wall Construction; Chapter 7, Wall Coverings, Chapter 8, Roof-Ceiling Construction &Chapter 9, Roof Assemblies of the 2020 International Residential Code of New York State, (IBC 2020); no exceptions. NO. DATE REVISIONS BY 2. ALL NEW WOOD SPECIES AND GRADE shall be Douglas 8'I — 91 811 — — — a compliant space t e oftion R408 4'-0" Fir-Larch #2, no exceptions; see charts above f r framing P Under — — — — — psection A sizes and spacing. he 2020 NYS Residential Code. . ALL NEW SILL PLATES for this proposed addition shall be pressure treated and ' ' '• I I (2) 2"xl2"hdr p provided with a continuous copper F New 8"thick a \ termite shied; see building sections on Drawing Z-3. N new 8 vent poured concrete foundation wall I \ 4. All NEW EXTERIOR SHEATHING for the roof shall be 3/4" ,10 2"x 8"floot joists I I thick exterior grade and the exterior sheathing for the walls @ 16"o.c. shall be 1/2" exterior grade. Both the roof and walls shall be new / weather protected with DUPONT TYVEK HOME W'�AP or an new Shrod�oe r approved alternate. crawl I :; I m s er `0 I ill a t h r o o m ( °� 5. The NEW FINISHED ROOF MATERIAL shall b,o Asphalt space I Roofing Shingles, (minimum 20 year); color style and ® manufacturer as selected by owner. dowel-in new foundation walls I 2"x 8"ce Lin joists &new footings into existing I @ 16'o.c. ° bb 6. All NEW CONCRETE FOUNDATION WORK under this celar unexcay. g (�Y Afoundation walls and footing Ipp cation shall comply with Chapter 4, Foundations, of the win ow 7wciw 2020 International Residential Code of New York State, (IBC with #5 re bars (2)r x °"oar.JL ll 2020); no exceptions. b a°o� 7. All NEW CONCRETE shall be a minimum of 3,000 psi saw-cut existing foundation I \ r (minimum specified compressive strength) in accordance with \ for new 16"x 24"access to Table 402.2; no exceptions. � S.D. S.D. crawlspace S 8. All NEW FOOTINGS shall be a minimum of 8" x 16" with three (3) #5 re-bars, continuous, lapped and tied for the length ��� �� of the new footings and in accordance with Section R403, c I I r up c Footings and Table 403.1; no exceptions. ntra icZ 9. All NEW CONCRETE FOUNDATION WALLS shall be a S.D. — minimum of 8" thick, minimum of 3,000 psi compressive master S.D. strength and in accordance with Section R404, Foundation & c e a r S.D. ll Retaining Walls; no exceptions. bedroo / � � 10. All NEW CONCRETE FOUNDATION WALLS shall be a - ° minimum of 8" thick, minimum of 3,000 psi compressive INTELLECTUAL PROPERY ACT of 2007 / " bedroom o strength and in accordance with Section R404, Foundation & 3 3_ _ Retaining Walls; no exceptions. OWNERSHIP OF DOCUMENTS: All drawings, plans --- -°-- - ---- U° 3 / " " � sketches, models, renderings, specifications & other u 11. FOUNDATION WATERPROOFING OF NEW CONCRETE / FOUNDATION WALLS shall be one layer of rigid insulation documents, including those in electronic format (pdf), prepared with a layer of bituminous coating in accordance w th Section by JTMA a.re Instruments of Service & are the sole property of / R406, Foundation Waterproofing; no exceptions. the Architect. JTMA, as the author & owner of these Instruments of Service holds all common law, statutory &. other rights including copyrights in the Instruments of Service. ce lar c II rr win ow "' ell DRAWN BY: D.M.S. DATE: 11.12.20 12'-21, cHKD BY: J.T.M. SCALE: AS NOTED PROPOSED PARTIAL CELLAR FLOOR PLAN xti PROPOSED PARTIAL FIRST FLOOR PLAN Xti PROJECT: 20-2025 SCALE: 114" = 1'-0" SCALE: 1/4" = 1'-0" PROJECT; SC EXISTING surface mounted,combination hard-wired smoke detector&carbon monoxide SC EXISTING surface mounted,combination hard-wired smoke detector&carbon monoxide MAINTAIN EXISTING CONCRETE PATIO & detector as per the requirements of Section R313.1 +R313.4 of the Residential Code of New York detector as per the requirements of Section R313.1 +R313.4 of the Residential Code of New York PROPOSED MASTER BATHROOM ADDITION TO AN State. State. EXISTING SINGLE FAMILY DWELLING GRAPHIC LEGEND PUGLIESE RESIDENCE Existing Exterior or Interior Wall Construction to Remain Unchanged 3600 SOUTH HARBOR ROAD A N D E R S E N W I N D O W S C H E D U L E E L E V A T 10 N S TOWN OF SOUTHOLD = _ __ = Existing Exterior or Interior Wall Construction to SUFFOLK COUNTY, NEW PORK 11971 be Removed as shown. WINDOW WINDOW JAMB EXTERIOR EXTERIOR GRILLE New Exterior Wall Construction; S.C.T.M. # 1000 - 75 - 8 - 3.1 WINDOW MANUFACTURER PRODUCT TYPE WINDOW TYPE MODEL # WIDTH HEIGHT WIDTH FINISH TRIM PROFILE INTERIOR OPTIONS HARDWARE GLASS QTY. REMARKS 2-11I 4-_0' see on Dwg. A-4 for further description DRAWING: A ANDERSEN 400 SERIES DOUBLE HUNG TW3046• 2' - 11 5" 3' - 0 Z" 6 1' T.B.D. T.B.D. T.B.D. T.B.D. T.B.D. Low-E4 1 North Wall of Proposed Master Bathroom Addition �- New 2"x 4"or 2"x b"Interior Wall Construction EXISTING & PROPOSED PLANS with Sound Batt Insulation (optional) B ANDERSEN 400 SERIES AWNING TW3032 4' - 0" 3' - 0" 6 2" T.B.D. T.B.D. T.B.D. T.B.D. T.B.D. Low-E4 1 West Wall of Proposed Master Bathroom Addition New Andersen Windows; see Floor Plans & CELLAR & FIRST FLOOR PLANS & Notes: Window Schedule WINDOW SCHEDULE Meet or exceed clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) & clear opening height of 24" (610) w/ appropriate hardware, straight- or split-arm operator. cf New Bathroom and/or Powder Room * Meet Clear Opening width of 20" (508) using sill hinge control bracket w/ split-arm operator specified (bracket can be pivoted for cleaning position) & meet clear opening width of 22" (559) with straight-arm operator specified. 75cfm Exhaust Fan, minimum 75 cfm SEAL: ? DRAWING: m ® New 4"x 6" Built-Up Structural Wood Posts A� (min.) at all new windows, see Floor Plans \�A�� ASR� Finish Floor gfi New Ground Fault interrupter Electrical Outlet A I3 �u- as required by Code a- TW210210 AXW41 9 Existing Exterior or Interior Doors to beA- I 1 light:5.62 sq.ft. light:9.46 sq.ft. �� removed &replaced ��� p16453 O vent:3.85 sq.ft. vent: 11.26 sq.ft. - TF OF N�� DWG: 00 OF: 00 COPYRIGHT 2020(c.)by James Thomas Martino, Architect, P.r�. 111 011 GENERAL NOTES 44 4'-0" `��6'-„1 44 O New cathedral ceiling in Proposed Master Bathroom - - - _ Addition;paint finish as selected by owner. see Section B-B i O New USG Sheetrock Brand MOLD TOUGH (GREEN) 7i dashed lines indicates proposed roof overhang, 2 BOARD on the walls and ceiling. \ I P>OA resdie ce v.overhang to match that of existingJ A M ES THOMAS MARTINO I resdience (v.i.f.) New two (2) recessed medicine cabinets with mirrors as see Section A-A 3 selected by the owner. A R C H I T E C T, P. C. ceramic or stone outdoor shower wall (2) 2"x 2"hdr 75 Nassau Avenue Teak shower enclosure New bathroom deck mounted sink faucets as \ O4 Manhasset,1 I ! P I 10"diameter,wall mounted,rain shower head manufactured by KOHLER or as selected by owner, New York 11030 as manuf,by KOHLER or an a 51 6 . 767 . 7888 e FAX 51 6 . 767 . 3986 -- - - — approved equal Email: info@jtmarchitect.com www,jtmarchitect.com 2 \ Teak shower mat within shower base New 5 foot long double sink vanity;as selected by co 4"curb w/clear or 5 l I etched tempered 4"Granite Shower Curb or a material approved O owner. FILE DATE TO BY 3 2 ® x 4'�0" glass above / by the owner 12.14.20 Three (3) Sets of Drawings J.T.M. l shower st - 6 New CERAMIC OR STONE FLOOR TILE as selected by the issued for filing with the 4 $ 11, O owner. TOWN OF SOUTHOLD ONew floor mounted TOILET as manufactured by TOTO or as selected by the owner. _ "wi T r 3'0 de Teak shower door New 3-0 X 61 ANDERSON FRENCH DOOR (or an 311"exterior° shower wall grade plywood sheathing for O approved equal) leading from the existing Master 7 I 50 Bedroom into New Master Bathroom Addition p I 2"x 6"exterior grade wood studs Q+/- 12"o.c. New free-standing ELISE SOAKING TUB 62.25"x 36"x 24") i., _ �2_cki x 5'-2' c B p o O as manufactured b MTI � X soaking tub i y or as selected by the owner. I N "x 4"Teak wood post �j ceramic or stone material to wrap around the 10 New 24"wide,TEMPERED GLASS SHOWER DOOR & r 4 ° exterior corners stationary fixed side panel;either clear or frosted glass OB I nXL ELEVATION ,A ELEVATION B o existing 11 New 3 foot tall x 4 foot wide awning window as SCALE: 1 2" = 1'-0" — SCALE: 1/2" = 1'-0" \ I / cellar window O manufactured by ANDERSEN or an approved equal. / (2) 2"x 1 fleader well new sto 3addle 12 New 4 in tall curb as manufactured by Meridian Elite 10 10 10'-2Jl existing window Series,Custom Shower Base &Threshold existing window to remain 4' \ I °ot 411 to remain New 3 foot tall x 3 foot wide double hung window as manufactured by ANDERSEN or an approved equal b56 \ of j/ 14 New 6'-6"x 4'-0"long TEMPERED GLASS STATIONARY N0. DATE REVISIONS BY FIXED SHOWER SIDE PANEL;either clear or frosted glass. ENLARGED BATHROOM AN Xti SCALE: 1/2" = 1'-0" I ❑ 13 10 ,l i / r 7 - - - - 12 6 L - - i � J ,l ELEVATION C_ ELEVATION D SCALE: 1/2" = 1'-0" — SCALE: 1/2" = 1'-0" INTELLECTUAL PROPERY ACT of 2007 - OWNERSHIP OF DOCUMENTS: All drawings, plans, "b"-symbol represents a new 2" "80 cfm"-symbol represents a new sketches, models, renderings, specifications & other diameter recessed LED light fixture, \ / BROAN-NUTONE recessed bathroom documents, including those in electronic format (pdf), prepared rated for a damp location,with an \ / exhaust fan (ultra silent series);white by JTMA are Instruments of Service & are the sole property of adjustable frost glass lens;white finish \ / finish the Architect. JTMA, as the author & owner of these Instruments of Service holds all common law, statutory & other New 4"Vent I I rights including copyrights in the Instruments of Service. Ne Roof ..c"-symbol represents a new 2" fhru I I I diameter recessed LED light fixture, rated for a exterior location;white finish DRAWN BY: D.M.S. DATE: 11.12.20 "j"-symbol represents a new I \ CHK'D BY: SCALE: recessed junction box at the ridge \ J.T.M. AS NOTED — beam for an owner supplied and the symbol represents a new wall mounted MASTER BATHROOM \ junction box for the owner su lied contractor installed chandelier \ pp /contractor PROJECT: installed wall sconce.location of the junction20-2025 I \ box is to be centered between the two medicine cabinets &the height coordinated in PROJECT : I I I I I I I \ \\ \ I the field with the owner. Sh er Tofet I Hand (Hand (Soaking I Outdoor MAINTAIN EXISTING CONCRETE PATIO & ° St II Sink Shk Tub Shower I \ I PROPOSED MASTER BATHROOM ADDITION TO AN %\ \ EXISTING SINGLE FAMILY DWELLING Stall I � �T2' I "c"-symbol represents a new 2" \ diameter recessed LED light fixture, ° I rated for a exterior location;white finish P U G LI E S E RESIDENCE T2' 3„ „ I \ 1 co c symbol represents a new wall 3600 SOUTH HARBOR ROAD mounted Thermostat for the new TOWN OF SOUTHOLD \ radiant heating throughout the Master SUFFOLK COUNTY, NEW YORK 11971 Bathroom floor ° PLUMBING RISER DIAGRAM j � ��j � DRAWING: S.C.T.M. # 1000 - 75 - 8 - 3.1 SCALE: 1/4" = 1'l ENLARGED BATHROOM (2) 2"x 10"header - T- PLAN, ELECTRICAL PLAN, Gra INTERIOR ELEVATIONS & PLUMBING RISER DIA. �6 SEAL; , DRAWING: MASTER BATHROOM ELECTRICAL PLAN - 2 SCALE: 1/2" = 1'-0" yT 016453 y0 F OF NEB DWG: 00 OF: 00 COPYRIGHT 2020 (c)by James Thomas Martino, Architect, P.C. GENERAL NOTES ONEW ASPHALT ROOFING SHINGLES are to match the +H++ J i FF-8 existing roofing sample from the property owner and confirm With the shingles;the contractor is to obtain a I+H+±il Master Bath_Fidqe 7 property owner that he can obtain the same material Beam Elevation prop ------- - prior to ordering. ____ ..............._.._____. __._.___. ._._..__-_-.___.-_______.___.__.___._._.__..._._._- - 1 O NEW HORIZONTAL SIDING is to match the existing J A M E s TH 0 M A S MA RT IN 0 A 5 horizontal siding; the contractor is to obtain a sample v from the property owner and confirm with the property A R C H I T E C T P. C. owner that he can obtain the same material prior to ordering. 75 Nassau Avenue 9 PROPOSED ADDITION 8 Manhasset, New York 11030 Master Bathroom Top O NEW DOUBLE HUNG VINYL WINDOW is to match the 5 1 6 7 6 7 7 8 8 8 - F A X 5 1 6 7 6 7 3 9 8 6 Plate Elevation \-(I) 1/2"thick gyp um board ceiling 2 5 existing double hung vinyl Window; the contractor is to Email: info@jtmarchitect.com www.jtmarchitect.com confirm With the property owner that he can obtain the 7-1/2"thick thermal batt insulation (R-21) same Window prior to ordering. FILE DATE TO BY ol 2 5 12 00, 11 6.'-Tm/indow_heig_h_t (2) �2"x 4" 5 F7: 5 ree 3 ets o Drawings O NEW AWNING STYLE VINYL WINDOW is to match the 121420 JTM. 3-1 er a )a lnsuiatio� -15) existing Vinyl Windows of the residence; the contractor — First Floor Ceiling 00 issued for filing with the X NOU stud i @ 16' o.( �5<_ is to confirm with the property owner that he can obtair TOWN OF SOUTHOLD (1) layer of '/," (o .51 ext, gr:ide plyw(( :)c sheathing 6'-g'w.h. the same style window prior to ordering. horizontal s di i g t Nmislbgsk in f residence 10 THE VERTICAL EXPOSURE&PATTERN of the New r 10 (DHORIZONTAL SIDING is to match the vertical exposure &pattern of the existing horizontal siding. OTHE SIZE AND MATERIALS FOR NEW WINDOW TRIM are to match the the size and material of the existing windows THE NEW OUTDOOR SHOWER ENCLOSURE will be a O 00 pre-fabricated unit purchased by the property owner 2" 4"s plate First Floor and installed by the general contractor. wood or_C(,11 a rr iic t! �e q s sere to by owner f THE ROOF PITCH of the new addition is to match the the roof pitch of the existing residence;the contractor is to wood orCEramic"'Xfod us seecled by owner I verify the existing roof pitch in the field and inform both thick pl ood sub-flo the property owner and the architect. Master Bathroom NORTH ELEVATION L-------------------------------------------------J THE ROOF OVERHANG of the new addition is to match Sub-Floor SCALE: 1/4" 1 -0" the roof overhang of the existing residence;the Existing Grade T contractor is to verify the existing roof overhang in the field and inform both the property owner and the 2"x 8"wo( d rim joist ............ architect. (2) 2"x 6"pressure treated sill plates O EXISTING DOUBLE HUNG VINYL WINDOW to remain continuous color er termite shield unchanged. New windows to match the existing. 1/2"steel 1-bolts,Ail washer&nut 8"poured concre e foundation wall a 11 NEW 4"BAKED ENAMEL,WHITE GUTTERS &LEADERS are NO. DATE REVISIONS BY 4 1 _�-2"crawlsp ceratsla-b ----- to match the profile of the existing gutters and leaders. 60 14 1..x 24"continuous rigid f unclation insulation (R5) 8"x 16"continuous poured concrete footing 8 SECTIONA—A PROPOSED ADDITION SCALE: 1/2" = V-0" 9 5 12 First Floor Ceiling 6-6'w.h. 10 4 10 10 8 Master BathRidge Beam Elevation 1 12 First Floor 5 9 Master Bathroom Top WEST ELEVATION r i Plate Elevation ------------------------------------------- Z(2) -2"x 4"ceiling joists wrapped with wood SCALE: 1/41' = 1'-0` 6'-8"window height (1) - 1/2"thick gypsum board ceilingINTELLECTUAL PROPERY ACT of 2007 7-1/2"thick thermal bait insulation (R-21) OWNERSHIP OF DOCUMENTS: All drawings, plans. (2) -2"x 4"top plate ri -------------------------------------------------------------I L1 sketches, models, renderings, specifications & other O 2 3-1/2"thick thermal Batt insulation (R-1 5) L----i documents, including those in electronic format (pdf), prepared by JTMA are Instruments of Service & are the sole property of 2"x 4"wood studs @ 16"o.c. (1) layer of 1/2" (or 3/4") ext.grade plywood sheathing the Architect JTMA, as the author & owner of these horizontal siding to match existing siding of residence Instruments of Service holds all common law, statutory & other rights including copyrights in the Instruments of Service. 8 9'-7*' DRAWN BY: D.M.S. DATE: 11.12.20 PROPOSED ADDITIO 2 5 CHKD BY: SCALE: J.T.M. AS NOTED 12 (1) -2"x 4"sole plate 5 11 PROJECT: wood or ceramic tile base as selected by owner 20-2025 wood or ceramic tile finish floor as selected by owner First Floor Ceiling PROJECT: 3/4"thick plywood sub-floor 6'-9'w.h. MAINTAIN EXISTING CONCRETE PATIO & Master BathroomPROPOSED MASTER BATHROOM ADDITION TO AN §66--FI-0-or s EXISTING SINGLE FAMILY DWELLING Existing Grade 2"x 8"wood rim joist (2) 2"x 6"pressure-treated sill plates PIUG LIE SE RESIDENCE continuous copper termite shield 4. 3600 SOUTH HARBOR ROAD o 1/2"steel j-bolts w/washer&nut �4 existing concrete foundation walls and TOWN OF SOUTHOLD 8"poured concrete foundation wall concrete footings to be remain First Floor 1 �4 unchanged;see proposed floor plan SUFFOLK COUNTY, NEW YORK 11971 S.C.T.M. # 1000 - 75 - 8 - 3.1 2"crawl space rat slab ..14 DRAWING: 1"x 24"continuous rigid foundation insulation (R5) 8"x 16"continuous poured concrete footing -------------------------------------------- EAST ELEVATION SECTIONS & EXTERIOR SCALE: 1/411 = 1 -0" ELEVATIONS ------------------------------- L J SEAL: DRAWING: n. C� <,NOMAS 4tj kt SECTION B-B . JSCALE: 1/2" = 1'-0` 01645 OF NEB DWG: 00 OF: 00 COPYRIGHT 2020(c)by James Thomas Martino, Architect, P.C. WiE Dc&EN r -8'�3• � ,OWN%, Van% GENERAL NOTESC E E Ar C F\ E U k IL Al 1.ALL WORK under this Application shall comply with the M /�\ l NTAI N EAISTI N u N T r- AT I \MOW/ R Resldentlal Code of New York State,2025. f 2. NO WORK shall proceed until such time as the TOWN OF Jill SOUTHOLD BUILDING DEPARTMENT has issued a Building Permit and a Plumbing Permit. Draw U N AN EX10t T M A D I T I T 'o ING MASm"ImE "I\"O" BATHI\Julu 3. The GENERAL CONTRACTOR certifies to the Owner that he J A M E S T H O M A S MARTIN O is a licensed Contractor in the State of New York; Suffolk County and fully insured as required by the TOWN OF A R Ci H I T E Ci T, P. C. SOUTHOLD BUILDING DEPARTMENT. 76 Nassau Avenue 4. The PLUMBING CONTRACTOR certifies to the Owner that Manhasset, New York 11030 IV Ilk Ar he is a fully licensed Contractor in the State of New York, 516 767 7 8$8 • FAX 516 767 3986 lkffSuffolk County and fully insured as required by the TOWN OF .0""' INULE FAMILlklAr mu"%h" WELLINU"O� SOUTHOLD BUILDING DEPARTMENT. Email: info@jtmarchitect.Com vvww.jtmarchitect.com 5. The ELECTRICAL CONTRACTOR certifies to the Owner that RI E DATE TO BY he is a fully licensed Contractor in the State of New York, Suffolk County and fully insured as required by the TOWN OF 12.1420 Three (3) Sets of Drawings J.T.M. SOUTHOLD BUILDING DEPARTMENT. . C issued for filing With the 6 The GENERAL CONTRACTOR is to field measure the TOWN OF SOUTHOLD rE existing conditions affected by this proposed work to confirm Three 3 Sets Of s.all dimensions prior to proceeding. 07.1126 O � J.T.M. �; issued to the owner for filing Witrl 7. The GENERAL CONTRACTOR is to inform James Thomas the TOWN OF SOUTHOLD .� Martino, Architect of any discrepancies between the field conditions and the dimensions indicated on these drawings prior to proceeding. 8. The GENERAL CONTRACTOR is responsible to coordinate the work performed by all trades, including but not limited to: his plumbing, mechanical and electrical sub-contractor's and any other trades that may affect this project. 9. The GENERAL CONTRACTOR is responsible to coordinate all locations where wood blocking and/or plywood backing TOWN OF SOUTH(OLD ZONING ANALYSIS INFORMATION may be necessary for a proper installation. 10. The GENERAL CONTRACTOR is to confirm all finishes ADDRF!SS: 3600 S HARBO)R ROAD,SOUTHOLD, NEW YORK 11791 with the property owner prior to ordering and/or installing any West Side of S�Harbor Road. finish materials. S.C.T.M. 1000-75-8-3.1 11. The GENERAL CONTRACTOR and his Electrical Sub-Contractor are responsible for coordination of all electrical Code Section Zoning[District Classification: R-80 Total Lot Area: 17,424.00 sq.ft. devices including but not limited to switches, gfci outlets, recessed lighting, surface mounted lightning, junction boxes, PERMITTED/REQUIRED EXISTING PROPOSED COMPLIANCE etc. V LOT SIZE. $ 12. The GENERAL CONTRACTOR and his PLUMBING Minimum Lot Size: 80,000 sq.ft. 17,424.00 sq.ft. Existing, No Change Pre-Existing SUBCONTRACTOR are responsible for the coordination of the plumbing fixtures, including but not limited to sinks,LOT WIDTH. NO. DATE REVISIONS BY faucets, toilet, soaking tub,shower controls,shower drain,etc. Minimum Lot Width: 175.00 ft. 100.00 ft. Existing,No Change Pre-Existing 13. The GENERAL CONTRACTOR is responsible to verify with /r Q his PLUMBING SUB-CONTRACTOR the size of the existing LOT DEPTH. f C Hot Water Heater(HWH)and whether the existing HWH will be Minimum Lot Depth: 250.00 ft. 204.23 ft. Existing, No Change Pre-Existing of sufficient capacity to support the additional hot water / = demand for the Master Bathroom. If deemed insufficient, the FRONT YARD. ,i GENERAL CONTRACTOR will submit to the Owner a separate Minimum Front Yard: 60.00 ft. 20.50 ft. Existin No Change Pre-Existing price quote remove and replace the existing HWH with a g. g g � � = new one of suu fficient capacity. SIDE YARD. C:) ° D 14. The ELECTRICAL SUB-CONTRACTOR is responsible for Minimum Side Yard: 20.00 ft. Side Yard 1: 6.18 ft. Existing, No Change Pre-Existing / 0 7O obtaining an Electrical ROUGHING Inspection approval from Side Yard 2:29.99 ft. O an independent Fire-Underwriter's Electrical Inspector. BOTH SIDE YARDS. �njO�� �Et\ M 15. The ELECTRICAL SUB-CONTRACTOR is responsible for obtaining a FINAL Electrical Inspection and an Underwriter's Minimum Both Side Yards: 45.00 ft. 36.17 ft. Existing,No Change Pre-Existing I rLOD� Electrical Certificate for the new work approval by an 70 independent Fire-Underwriter's Electrical Inspector. REAR YARD. N O Minimum Rear Yard: 75.00 ft. 74.69 ft. Existing,No Change Pre-Existing / o 16. The GENERAL CONTRACTOR shall submit to the Owner's D I v the Original (green) FINAL Underwriters Electrical Certificate LIVABLE FLOOR AREA. S for submission to the TOWN OF SOUTHOLD BUILDING Minimum Floor Area: 850.00 sq.ft. 1,668.65 sq.ft. 1,774.25 sq.ft. Yes, Complies DEPARTMENT / Z\4 17. The GENERAL CONTRACTOR and his Sub-Contractor(s) LOT COVERAGE. /0' / OV0- shall make any and all changes to their work as deemed Maximum Lot Coverage: 20% (3,484.80 sq.ft.) 9.58% (1,668.65 sq.ft.) 10.18%(1,774.25 sq.ft.) Yes, Complies - necessary by the TOWN OF SOUTHOLD BUILDING INSPECTOR at no additional cost to the owner. BUILDIWG HEIGHT. Maximum Building Height: 35.00 ft. t 13 ft. f 13 ft. Yes, Complies .00 18. All New Conventional Wood Framing Members shall be o�� O,� / Douglas Fir-Larch #2 minimum, NO EXCEPTIONS. NUMBER OF STORIES. h5 O• Maximum No.of Stories: 2 Stories 1 Story Existing, No Change Yes, Complies C� �,O / SrOOP 19. Written dimensions shah take precedence over scaled dimensions and detailed drawings over smaller scale drawings. 20. The GENERAL CONTRACTOR shag verify& be responsible for all existingdimensions & conditions on the job. The Architect's latest revised dwgs. - 09.23.26 CALCULATIONS: / \3`P\G�QP��O Office must be notified of any deviations of he dimensions and MAXIMUM PERMITTED LOT COVERAGE. _ 00P ./ �G�C�' conditions indicated on these drawings. INTELLECTUAL PROPERY ACT Of 2007 - Existing Single Family Dwellling Footprint 1,668.65 sq.ft. \ 21. The GENERAL CONTRACTOR shall be responsible for bracing OWNERSHIP OF DOCUMENTS: All drawings, plans, Pro pm Addition = 105.60 sq.ft. 0,��' &protecting against wind&storm damage, breakage,collapse, Total Lot Coverage = 1,774.25 sq.ft. �� ;sketches, models, renderings, specifications & other QP G� `t distortion and misarignment of all areas affected by this Maximum Permitted Lot Coverage =3,484.80 sq.ft., under by 1,710.55 sq.ft therefore Complies / P� r�0 � alteration. documents, including those in electronic format (pdf , prepared / Q QCR S�0 �S by JTMA are Instruments of Service & are the sole property of O �� 22.The GENERAL CONTRACTOR shall be responsible for recording GROSS FLOOR AREA CALC:UlATIONS. Q�00 6�0 51 accurate "AS-BUILT" DOCUMENTS of an chan es made duri the Architect. JTMA, as the author & owner of these Existin()Single Family Dwellling (1st Floor) = 1,668.65 sq.ft. P ��- o 1`' y g Instruments of Service holds all common law, statutory &other Pro osed Addition = 105.60 sq.ft. 1 the course of this Alteration. rights including copyrights in the Instruments of Service. Total Existing Gross Floor Area = 1,774.25 sq.ft. 23. The GENERAL CONTRACTOR will be solely responsible for the Minimum Permitted Gross Floor Area = 850.00 sq.ft.,over by 924.25 sq.ft.therefore Complies N / restoration,replacement and/or repair of any and all areas that were damaged by his own work force and any of his DRAWN BY: DATE: Sub-Contractors during this construction. D.M.S. 07.11.26 G1 6, CHK'D BY: J.T.M. SCALE: AS NOTED MATERIAL SYMBOLS DRAWING INDEX PROJECT:t PROJECT: 20-2025 SHE SHEET INFORMATION EARTH ® BRICK ® WOOD BLOCKINGOO� MAINTAIN EXISTING CONCRETE PATIO & EXISTING SINGLE FAMILY DWELLING GENERA! o o a STONE FILL ® ALUMINUM PLYWOOD z o D�OOq PROPOSED MASTER BATHROOM ADDITION TO AN G0 SITE PLAN,ZONING7ANALYSIS&NOTEs CONCRETE STEEL GLASS S �O ARCHITECTURAL. C7 N PUGLIESE RESIDENCE A_1 EXISTING&PROPOSED PLANS.CELLAR&FIRST FLOOR PLANS&WINDOW SCHEDULE �•• SAND ® WOOD FINISH ® BATT INSULATION A-2 ENLARGED BATHROOM PLAN,ELEC.PLAN,INT.ELEVATIONS&PLUMBING RISER DIA. �� 3600 SOUTH HARBOR ROAD �l. CONC.BLK. ® WOOD ROUGH M RIGID INSULATION TOWN OF SOUTHOLD A-3 SECTIONS&EXTERIIOR ELEVATIONS '� -, z I. SUFFOLK COUNTY, NEW YORK 11971 SYMBOL LIST 34`-61 a, _' S.C.T.M. # 1000 - 75 - 8 - 3.1 OCT 2 2t'=.-0 DRAWING: DETAIL NUMBER -# DRAWING NUMBER [ REVISION # SITE PLAN, ZONING SECTION NUMBER ANALYSIS & NOTES DRAWING NUMBER INTERIOR ELEVATION SPOT ELEVATION PROPOSED SITE PLAN SEAL: DRAWING: SCALE:*'= v-0" 4, NOTE: ALL METES&BOUNDS INFORMATION HAS BEEN TAKEN FROM A SURVEY PREPARED BY: PAUL BARYLSKI LAND SURVEYING a ty r PATCHOGUE,NEW YORK]]772 '�' 0 PHONE:(631)294-6985 (P E:_"-�;, r-- FAX:(631) 627-3186 Q� EMAIL:PAULBARYLSKIGYAHOO.COM 9� 01f453 �O SURVEY LAST DATED FEBRUARY 3,2017 Ofi N E S.C.T.M.# 1000075000800003001 DWG: 00 OF: 00 COPYRIGHT 2026 c by James Thomas Martino, Architect, P.C. FRAMING NOTES Based upon Table R502.3.1(1)- 20-1 14-4 13'-11 f FLOOR JOIST SPANS for Common Lumber Species RESIDENTIAL SLEEPING AREAS(above) c lar unexcav, cellar Live Load: 40 psf wi ow window Dead Load: 20 psf Joist Spacing: 17,o.c. Species&Grade: Douglas Fir-Larch#2 J A M E S T H O M A S M A R T I NO Joist Size: 2"x 8"Wood Celf[ng Joists w Maximum Permitted Joist Span @ 12"o.c.= 14'9" Actual Maximum Joist Span=11'4";therefore,o.k. A R C H I T E C T, P. C. Note:Contractor to provide solid wood blocking at mid-span 75 Nassau Avenue Manhasset, New York 11030 of el in lonc ete // �� 51 6 . 767 . 7888 • FAX 51 6 . 767 . 3986 Mein s up t°g e �\ // a Based upon Table R802.4 2 - Email: info@jtmarchitect.com www.itmarchitect.com O CEILING JOIST SPANS for Common Lumber Species c UNINHABITABLE ATTICS WITH LIMITED STORAGE AREAS(above) FILE DATE TO BY Live Load: 20 psf s.D c e I I a r s.D master Dead Load: 10 psf 12.14.20 Three (3)Sets of Drawings J.T.M. r bedroom Joist Spacing: 16"o.c. issued for filing with the Species&Grade: Douglas Fir-Larch#2 TOWN OF SOUTHOLD t Joist Size: 2"x 8"Wood Ceiling Joists Maximum Permitted Joist Span: 16'-6' 071126 Three(3) Sets of Dwgs. J.T.M. "o bedroom o Actual Maximum Joist Span: 13'-3",therefore,o.k. s o o issued to the owner for filing with e.g ° Note:Contractor to provide solid wood blocking at mid-span the TOWN OF SOUTHOLD Based upon Table R802.5.1 (1) - ROOF RAFTER SPANS for Common Lumber Species Roof Live Load: 20 psf Roof Dead Load: 20 psf ce lar c r Joist Spacing: 16' O.C. wini wir d w Species & Grade: Douglas Fir- Larch #2 u el Joist Size: 2"x 8"Roof Rafters 1z-2• 2'0" Maximum Permitted Joist Span: 16'-0" Actual Greatest Joist Span:9'-11", therefore,o.k. EXISTING CELLAR FLOOR PLAN EXISTING FIRST FLOOR PLAN x�' SCALE: 1/4" = T-0" SCCALE: 1/4" = V-0" GENERAL NOTES SC EXISTING surface mounted,combination hard-wired smoke detector&carbon monoxide SiC EXISTING surface mounted,combination hard-wired smoke detector&carbon monoxide detector as per the requirements of Section R313.1 +R313.4 of the Residential Code of New York detector as per the requirements of Section R313.1 +R313.4 of the Residential Code of New York 1. ALL WOOD FRAMING WORK under this Application shall comply with Chapters 5, Floors;Chapter 6,Wall Construction; State. State. Chapter 7,Wall Coverings, Chapter 8, Roof-Ceiling Construction&Chapter 9, Roof Assemblies of the Residential Code of New York State,2025; no exceptions. 2. ALL NEW WOOD SPECIES AND GRADE shall be Douglas NO. DATE REVISIONS BY =hb r a s-0' 3 0• 3'-0' 1'0' Fir-Larch #2, no exceptions; see charts above for framing a s' a 1Usizes and spacing. — — — — New CRAWL SPACE will ben ad eo fro�i: 2-� '�'2 a b b constructed in strict compliance with 3. ALL NEW SILL PLATES for this proposed addition shall be pressure treated and provided with a continuous copper Section R408 Under-Floor space of the termite shield;see building sections on Drawing A-3. F I 2025 NYS Residential Code. ,'shower New 16"x 8"crawl dr 4. All NEW EXTERIOR SHEATHING for the roof shall be 3/4" j I I I N space vent with ( st, all thick exterior grade and the exterior sheathing for the walls ( 2"x 8"(loot joists I insect screen r x s- f rafters / shall be 1/2 exterior grade. Both the roof and was shall be New 16"x 8"crawl • @ 16"o.c. t~ ltr radius btw1lt-in o.c, weather Outline of concrete ( protected with DUPONT TYVEK HOME WRAP or an space vent with I I I ,` I pad for new outdoor mower<seot / approved alternate. insect screen 1 b § aor o N 1 1 new I (_ I N b shower b ih 1 m n 5. The NEW FINISHED ROOF MATERIAL shall be Asphalt I crawl space I New 8"thick ° Roofing Shingles, (minimum 20 year); color style and new 2"thick concrete slab ' poured concrete ,r high clear t wall edith r—c m a t e r �, t manufacturer as selected b owner. j I (min.3,000 psi) with 6x6-6x6 I I foundation wall shower ate con 1 lba t h r o o m . y w.w.f.on vapor barrier I I ry l 6. All NEW CONCRETE FOUNDATION WORK under this e 7'x c Lin 'fists o o ♦ Application shall comply with Chapter 4, Foundations,of the a 1 o.c. rwcn. Iar unE xcay. �— ? cellar Residential Code of New York State, 2025; no exceptions. new(2) 2"x g'header 4 I°N t212-x 1 Header Mnnwell dow 7. Alf NEW CONCRETE shall be a minimum of 3,000 psi f \ bsb (minimum specified compressive strength)in accordance with \ } / Table 402.2;no exceptions. saw-cut existin owel4n new foundation walls&new 8.3-0• \ j three All NEW FOOTINGS shall be a minimum of for x e l with foundation for a new footings into existing foundation walls and S,D D minimum 30"wide x 24"tall footing with#5 re-bars vertically @ 24"o.c. three(3)#5 re-bars, continuous,lapped and tied for the length I of the new footings and in accordance with Section R403, opening into the new crawl spacer new addition \ 11-8' Footings and Table 403.1; no exceptions. c II r 9. All NEW CONCRETE FOUNDATION WALLS shall be a up \inra c m minimum of 8" thick, minimum of 3,000 psi compressive c strength and in accordance with Section R404, Foundation & Retaining Walls; no exceptions. G c e I 1 a r SD bed oomaster� FOUNDATION FOUNDATION WATERPROOFING ye NEW CONCRETE latest revised dwgs. - 09.23.26 r I u FOUNDATION WALLS shall be one layer of rigid insulation / ♦ with a layer of bituminous coating in accordance with Section ♦ ° R406, Foundation Waterproofing; no exceptions. INTELLECTUAL PROPERY ACT of 2007 3 o bedroom o OWNERSHIP OF DOCUMENTS: All drawings, plans, E T u " bei-0 I sketches, models, renderings, specifications & other K�L / o documents, including those in electronic format (pd% prepared 3 b JTMA are Instruments of Service & are the sole roe of o Y property�Y / .0 the Architect. JTMA, as the author & owner of these V) Instruments of Service holds all common law, statutory & other riights including copyrights in the Instruments of Service. �r win ow ( DRAWN BY: D.M.S. DATE: 07.11.26 n IL 12'-2• cHK'D BY: J.T.M. SCALE: AS NOTED PROPOSED PARTIAL CELLAR FLOOR PLAN x4, PROPOSED PARTIAL FIRST FLOOR PLAN xti PROJECT' 20-2025 SCALE: 1/4" = T-0" StCALE: 1/4" = T-0" PROJECT: SC EXISTING surface mounted,combination hard-wired smoke detector&carbon monoxide S;C EXISTING surface mounted,combination hard-wired smoke detector&carbon monoxide MAINTAIN EXISTING CONCRETE PATIO & PROPOSED MASTER BATHROOM ADDITION & AN detector as per the requirements of Section R313.1 +R313.4 of the Residential Code of New York detector as per the requirements of Section R313.1 +R313.4 of the Residential Code of New York State. State. EXISTING SINGLE FAMILY DWELLING GRAPHIC LEGEND PLIGUESE RESIDENCE Existing Exterior or Interior wall Construction to Remain Unchanged 3600 SOUTH HARBOR ROAD ANDE IRS EN WINDOW SCHEDULE ELEVATIONS =___- SUFFOLTOWN NOYSOUTOORK11971 — Existing Exterior or Interior Wall Construction to LD be Removed as shown. WINDOW WINDOW JAMB EXTERIOR EXTERIOR GRILLE New Exterior Wall Construction; S.C.T.M. # 1000 - 75 - 8 - 3.1 WINDOW MANUFACTURER PRODUCT TYPE WINDOW TYPE MODEL # WIDTH HEIGHT WIDTH FINISH TRIM PROFILE INTERIOR OPTIONS HARDWARE GLASS QTY. REMARKS 1 9 31�-1 �( see on Dwg.A-4 for further d escription DRAWING: A ANDERSEN 400 SERIES DOUBLE HUNG TW18310 1' - 9 ' 4' - 0 �" 3 1" T.B.D. T.B.D. T.B.D. T.B.D. T.B.D. Low-E4 1 North Wall of New Master Bathroom — � _ _ I I New 2"x 4"or 7'x 6'Interior Wall Construction EXISTING & PROPOSED PLANS, $ with Sound Batt Insulation (optional) B ANDERSEN 400 SERIES; FIXED DHP30310 3' - 1 �" 4' - 0 g" 3 T.B.D. T.B.D. T.B.D. T.B.D. T.B.D. Low-E4 1 West Wall of New Master Bathroom New Andersen windows;see Floor Plans& CELLAR & FIRST FLOOR PLANS & Notes: Window Schedule WINDOW SCHEDULE Meet or exceed clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) & clear opening height of 24' (610) w/ appropriate hardware, straight- or split-arm operator. ra zs�fm New Bathroom and/or Powder Room Meet Clear Opening width of 20" ((508) using sill hinge control bracket w/ split-arm operator specified (bracket can be pivoted for cleaning position) & meet clear opening width of 22" (559) with) straight-arm operator specified. 6 Exhaust Fan,minimum 75 cfm Date: 10/04/16 double hung fixed 0 New 4"x 6"Built-Up Structural Wood Posts SEAL: DRAWING: Scale: 8" 3 1' 305 (min.) at all new windows,see Floor Plans Finish Floor sfl New Ground Fault interrupter Electrical Outlet A B as required by Code 4Z l A- F� TW18310 DHP30310 9 d' Existing Exterior or Interior Doors to be I$� ; � A— \ removed &replaced Q. 01645s p OF N � DWG: 00 OF: 00 COPYRIGHT 2026 c by James Thomas Martino, Architect, P.C. g._ GENERAL NOTES 4-1 0J 6 ' 1 New cathedral ceiling in Proposed Master Bathroom Addition;paint finish as selected by owner. 2 New USG Sheetrock Brand MOLD TOUGH (GREEN) e 10"radius built-in ` shower shower / dashed fines indicates proposed roof overhang, O BOARD on the walls and ceiling. shower seat head controls / I dimenions of overhang to match that of existing resilience (v.iJ.) J A M E S T H O M A S MARTIN O - - - New two (2) recessed medicine cabinets with mirrors as 011 see Section A-A 3 selected by the owner. A R C H I T E C T, P. C. (2) 2"x12"hdr I ceramic or stone outdoor shower wall Teak shower enclosure 75 Nassau Avenue ONew bathroom deck mounted sink faucets as Manhasset, New York 11030 i71 I 24°shower dr I 10"diameter,wall mounted,rain shower head 4 manufactured by KOHLER or as selected by owner, 5 1 6 7 6 7 7 8 8 89 F A X 5 1 6 7 6 7 3 9 8 6 as manuf.by KOHLER or an approved equal Email: info@jtmarchitect.com www.jtmarchitect.com 2 I Teak shower mat within shower base O New 5 foot long double sink vanity;as selected by 4'-6 -9" owner. FILE DATE TO BY I sh an "Granite Shower Curb or a material approved by the owner 12.14.20 Three (3) Sets of Drawings J.T.M. \New CERAMIC OR STONE FLOOR TILE as selected by th issued for filing with the 4 �N g \ / �/ owner. TOWN OF SOUTHOLD r 5 9 New floor mounted TOILET as manufactured by TOTO o 07.1126 1 hree(3) Sets of Dwgs. J.T.M. \2�4e"x o issued to the owner for filing with solid core as selected by the owner. g 6 wood door o / the TOWN OF SOUTHOLD 3'-0"wide Teak shower door — -- 42"high low wal with clear C New 2'1 X 6'-8"solid core wood door as selected by tempered sh er glass a 3/4"exterior grade plywood sheathing for C!)the owner leading from the existing Master Bedroom enclosure O shower wall into the New Master Bathroom Addition 1 OIEHIF I 0 C .Q 2"x 6"exterior grade wood studs @+/_17'o.c. 9 New area for make-up vanity to be selected by owner AM B 1 C > I O O Q -a "x 4"Teak wood post � � � � ceramic or stone materiel to wrap around the 10 New 24"wide,TEMPERED GLASS SHOWER DOOR & L____ O o o exterior comers stationary fixed side panel;either clear or frosted glass �- I , existing New 3 foot wide x 4 foot tall FIXED window as ELEVATION A ELEVATION B O cenar window manufactured by ANDERSEN or an approved equal. SCALE: 1/2" = VI SCALE: 1/2' = V-0" -' J1 I1 (2) 2"x 10" header r well 12 New 4 inch tall curb as manufactured by Meridian existing window existing window Elite Series,Custom Shower Base&Threshold to, {p to remain 4" ` *�+ / New 2 foot wide x 4 foot tall DOUBLE HUNG window as manufactured by ANDERSEN or an approved equal New TEMPERED GLASS STATIONARY FIXED SHOWER SIDE NO. DATE REVISIONS BY ENLARGED BATHROOM AN / PANEL;either clear or frosted glass. SCALE: UT = VI x clear \ / t 1pered glass cl \ 10 �r to e d 13 r' "' ss 11 2 ,IN r 7 lip i 12 6 m M LLI I I I I I I I ELEVATION' C ELEVATION D SCALE:1/2" = V-0" SCALE: 1/2' = 1"-0" DATE:04.24.26 DATE: 04,24.26 latest revised dwgs. - 09.23.26 INTELLECTUAL PROPERY ACT of 2007 - OWNERSHIP OF DOCUMENTS: All drawings, plans, "b"-symbol represents a new 2" "80 cfm"-symbol represents a new sketches, models, renderings, specifications & other diameter recessed LED light fixture, \ j BROAN-NUTONE recessed bathroom documents, including those in electronic format (pdf), prepared rated for a damp location,with an \ / I exhaust fan(ultra silent series);white by JTMA are Instruments of Service & are the sole property of adjustable frost glass lens;white finish \ / finish the Architect. JTMA, as the author & owner of these Instruments of Service holds all common law, statutory&other New 4"Vent I rights including copyrights in the Instruments of Service. thru Roof "c"-symbol represents a new 2" diameter recessed LED light fixture, ( I \ I rated for a exterior location;white finish DRAWN BY: DATE: 24 shower D.M.S. 07.11.26 symbol represents a new dr CHK'D BY: SCALE: recessed junction box at the ridge J.T.M. AS NOTED beam for an owner supplied and the � / "jb"-symbol represents a new wall mounted MASTER BATHROOM ea contractor installed chandelier j junction box for the owner supplied/contractor —' installed wall sconce.location of the junction PROJECT. 20-2025 —1 1—72� 2 4'-6 x.5' box is to be centered between the two I ( I I I I showeir sto I medicine cabinets&the height coordinated in PROJECT: the field with the owner. Sh er Tolet �Hand I Hand I Outdoor � \ j MAINTAIN EXISTING CONCRETE PATIO & St II Sink Sink Shower I \ ' PROPOSED MASTER BATHROOM ADDITION TO AN T EXISTING SINGLE FAMILY DWELLING Stall '� ` \ ' "c"-symbol represents a new 2" I I \ diameter recessed LED light fixture, \ I \\ C rated for a exterior location;white finish PUGLIESE RESIDENCE co C \\ v, 3600 SOUTH HARBOR ROAD I I a "7'-symbol represents a new wall o I > \ mounted Thermostat for the new TOWN OF SOUTHOLD a \ 01 radiant heating throughout the Master SUFFOLK COUNTY, NEW YORK 11971 Bathroom floor E 0 S.C.T.M. # 1000 - 75 - 8 - 3.1 PLUMBING RISER DIAGRAM L j i I DRAWNG: +SCALE: 1/4" = 1'-0'� (2) 2"x 1 ' header T ENLARGED BATHROOM Nil x"114 PLAN, ELECTRICAL PLAN, 10 INTERIOR ELEVATIONS & PLUMBING RISER DIA. SEAL: DRAWING: �ii--kED AqC MASTER BATHROOM ELECTRICAL PLAN xti � -2 SCALE: 1/2" = 1'-0" r `� ,�- -7 , 016453 of N E � DWG: 00 OF: 00 COPYRIGHT 2026 c by James Thomas Martino, Architect, P.C. GENERAL NOTES 8 NEW ASPHALT ROOFING SHINGLES are to match the Master Bath Ridge existing roofing shingles;the contractor is to obtain a Beam Elevation sample from the property owner and confirm with the 1 property owner that he can obtain the some material prior to ordering. O NEW HORIZONTAL SIDING is to match the existing J A M E S T H O M A S MARTIN O V-611 horizontal siding; the contractor is to obtain a sample e from the property owner and confirm with the property A R C H 1 T E C lT, P. C. (1)-1/2"thick gy sum board ceiring 9 owner that he can obtain the same material prior to Master Bathroom Top ordering. 75 Nassau Avenue Plate Elevation PROPOSED aDDrrloN 8 Manhasset New York 1030 Rockwool Comt rtbott Stone Woo it Insutatton,7- 12"thick,R-30 O NEW DOUBLE HUNG VINYL WINDOW is to match the 51 6 . 7 6 7 . 7 8 8 89 F A X 5 1 6 . 7 6 7 . 3 9 8 6 ......-.. ,.. existing double hung vinyl window, the contractor is to 6'-8"window height - 2 5 2 5 Email: info@jtmarchitect.com www.jtmarchitect.com g confirm with the property owner that he can obtain the 1/2-thick 5)high d777 ensity same window prior to ordering. FILE DATE TO BY 2' 6"wood studs @ 16"o.c. 12.14.20 J.T.M. ► 1 11 4 NEW FIXED WINDOW is to match the existing vinyl 1 hree (3) Sets of Drawings t (1) layer of 1 2' or 3/4")ext.grade plyo d sheathing O windows of the residence: the contractor is to confirm First Floor Ceiling 9 with the issued for filing with the E; {1)layer o "thick dgIf insulation oo rd(R-6 ' 2"th r al rigid ins ration boa grope y owner at a can obtain the same TOWN OF SOUTHOLD 6'_g"v,•h• 6 style window prior to ordering. 07.1126 1Ylree(3) Sets of Dwgs. J.T.M. horizontal si i to match existing sidii f residence 10 10 O THE VERTICAL EXPOSURE& PATTERN of the New issued to the owner for filing with I - HORIZONTAL SIDING is to match the verticat exposure the TOWN OF SOUTHOLD ili ==34 & pattern of the existing horizontal siding. h O THE SIZE AND MATERIALS FOR NEW WINDOW TRIM are to I I match the the size and material of the existing windows r '00 (1)-2"x 6.sole plate 7 THE NEW OUTDOOR SHOWER ENCLOSURE will be a wood ore mic the base as selec by owner pre-fabricated unit purchased by the property owner I First Floor and installed by the general contractor. wood or ce Ic the finish floor as sel t d by owner O THE ROOF PITCH of the new addition is to match the I 3 "thick pl ood sub f1 j�—dashed lines indcate new conc.—?'j 8 roof pitch of the existing residence;the contractor is to Master Bathroom 2'x 8"woo § foundation walls for new addition verify the existing roof pitch in the field and inform both the property owner and the architect. Sub-Floor continuous copper termite shield NORTH ELEVATION L J THE ROOF OVERHANG of the new addition is to match l.J the roof overhang of the existing residence;the Existing Grade FINISHED GRADE new min.8"thick thermal insulat n between the floorjoists(R-21 i SCALE: 1/4" = V-0" contractor is to verify the existing roof overhang in the 1/2"dia.st I anchor bolts,(each w/washer&nut (2)2"x 6"pressure-treated sill plates , field and inform both the property owner and the 1"rigid insulation board(R-6) 8"thick concrete foundation wall(min.3,000 psi) 0) architect. one(1)#5 re'bar vertical @ 48"o.c. _ 1"pre-molded expansion joint at found.wall/floor slab •. CV - O EXISTING DOUBLE HUNG VINYL WINDOW to remain 0, O 2"thick"rat slab"(min.3,000 psi with 6x6-6x6 w.w.f. 10 unchanged.New windows to match the existing. three(3) #5 re-bars,continluous,lapped and tied co new cra I space NEW 4"BAKED ENAMEL, WHITE GUTTERS &LEADERS are NO, DATE REVISIONS BY 11 to match the profile of the existing gutters and leaders. 00 • 1"x 24"continuous rigid foundatlire insulation (R-6) '•• I continuous vapor barrier under new conc.floor slab Jam•- 1,�. � 0,E 1,-4„ -4 8 SECTION A-A I SCALE: 1/2" = V-0" 1 1 PROPOSED ADDITION Note:The total Thermal R-Value of the exterior walls is as follows: 1) 3-1/2'thick thermal batt insulation(R-15) high density 9 5 12 2) One layer of 1"thick rigid insulation board(R-6) 1 3) One layer of 2"thermal rigid insulation board(R-13) First Floor Ceiling 5 2 R-15+R-6+R-13=R-34 Total Thermal R-Value for each of the three(3)exterior walls is R=34 6 6-8"w.h. 10 4 10 10 fix d + 8 Master Bath Ridge Beam Elevation First Floor ( 1 12 = - 5 � I I I r' ----r--------------� I 9 WEST ELEVATION L- J dashed lines indicate existing Master Bathroom Top SCALE: 1/4" = 1'-0° I poured concrete foundation walls ; latest revised dwgs. - 09.23.26 Plate Elevation dashed lines indicate new conc. I I foundation walls for new addition J (2)-2"x 4"ceiling joists wrapped with wood ' INTELLECTUAL PROPERY ACT of 2007 - '6' I-8"wind I OWNERSHIP OF DOCUMENTS: All drawings, plans, ow height (i)-1l2"thick gypsum board ceiling -------—--------------I Lli sketches, models, renderings, specifications & other Rockwool Comfortbalt Stone Wool L-_-1 L-__l documents, including those in electronic format (pdf), prepared Insulation,7-1/2"thick,R-30 by JTMA are Instruments of Service & are the sole property of 2 (2)-2"x 6"top plate the Architect. JTMA, as the author & owner of these 3-1/2"thick thermal bait insulation(R-15)high density Instruments of Service holds all common law, statutory&other 2"x 6"wood studs @ t 6"o.c. rights including copyrights in the Instruments of Service. I (1) layer of 1/2'(or 3/4")ext.grade plywood sheathing (t)layer of t"thick rigid insulation board(R-6) �a 1. 8 DRAWN BY: DATE: J D.M.S. 07.11.26 2"thermal rigid Insulation board(R-13) PROPOSED ADDrnON 2 5 horizontal siding to match existing siding of residence CHK'D BY. J.T.M. SCALE: AS NOTED 12 11 1 ©5 PROJECT' 20-2025 (1)-2"x 6"sole plate First Floor Ceiling 9 wood or ceramic the base as selected by owner PROJECT. wood or ceramic the finish floor as selected by owner C-8 w.h• 7 MAINTAIN EXISTING CONCRETE PATIO & 3/4"thick plywood sub-floor PROPOSED MASTER BATHROOM ADDITION TO AN EXISTING SINGLE FAMILY DWELLING Master Bathroom Sub-Floor existing wood floor joists to remain unchanged PUGLIESE RESIDENCE new min.8"thick thermal insulation between the floor joists(R-21) Existing Grade new 2"x 8"wood rim joist 3600 SOUTH HARBOR ROAD 1/2"dia.steel anchor bolts,each w/washer&nut new(2) 2"x 6"pressure-treated sill plates TOWN OF SOUTHOLD 1"rigid insulation board(R-6) new continuous copper termite shield First Floor SUFFOLK COUNTY, NEW YORK 11971.. .: one(1)#5 rebar vertical @ 48"o.c. _ new I"pre-molded expansion joint at found.wall/floor slab O new 2"thick"rat slab"(min.3,000 psi) with 6x6-6x6 w.w.f. S.C.T.M. # 1000 - 75 - 8 - 3. Cl) new crawl space ' I DRAWING: three(3) #5 re-bars,continuous,lapped and tied I" I k dashed lines indicate new conc. • . •, • ' ______________ foundation walls for new addition EAST ELEVATION ~-- SECTIONS & EXTERIOR • 1"x 24"continuous rigid foundation insulation(R-6) SCALE: 1/4" = 1'-0" ELEVATIONS continuous vapor barrier under entire new conc.floor slab I dashed lines indicate existing poured concrete foundation walls SECTION B-B --------------- „ existing concrete foundation walls and SEAL: � DRAWING: SCALE: 1/2" = 1 -0 concrete footings to be remain L—J Note:The total Thermal R-Value of the exterior walls is as follows: unchanged;see proposed floor plan QED A 1) 3-1/2"thick thermal batt insulation(R 15)high density 2)I One layer of 1"thick rigid insulation board(R-6) 1 3)I One layer of 2"thermal rigid insulation board(R-13) •y.. -3 R-•15+R-6+R-13=R-34a Twtol Thermal R-Value for each of the three(3)exterior walls Is R=34 ��- y� 01 G453 �O OF N DWG: 00 OF: 00 COPYRIGHT 2026 c by James Thomas Martino, Architect, P.C.