Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
47705-Z
TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE '� rr SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 47705 Date: 4/20/2022 Permission is hereby granted to: Er ulec, Hakan wwwwwwwwwwwwwww_......................................_._..._a_......... 415 W 23rd St Apt 4Bwwwwww_............... ._..._._._._._. _._...... New York, NY 10011 .............._................_..wwww... w.w...n,............._...-._........ .__. To: alter from oil to natural gas in existing single-family dwelling as applied for. At premises located at: 1580 Country Club Dr, Cutchoglue SCTM # 473889 Sec/Block/Lot# 109.-3-2.16 Pursuant to application dated 3/21/2022_ and approved by the Building Inspector. To expire on _1.0/29-/20.2.3 wwwww_ .ww Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $200.00 CO-ALTERATION TO DWELLING $50.00 Total: $250.00 Buil �n .. �. torww.._wwwwwwww TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. 0. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631)765-95021 :/ wwr . cauthcaldt:owrn . oar Date Received APPLICATION FOR BUILDING PERMIT t or Office Use Only PERMIT NO. ./ Building Inspector: Applications and forms must be filled out in their entirety.Incomplete nlDl� applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. TOWN 06..SOUTHOLD Date: 3/21/2022 OWNER(S)OF PROPERTY: Name: Hakan & Lee ErgulecscTM#1000-109-3-2 Project Address: 1580 Country Club Dr, Cutchogue, NY 11935 Phone#: 917-690-9618 1 Email: hergulec@gmail.com Mailing Address: 1580 Country Club Dr, Cutchogue, NY 11935 CONTACT PERSON: Name: Hakan Ergulec Mailing Address: 1580 Country Club Dr, Cutchogue, NY 11935 Phone#: 917-690-9618 Email: hergulec@gmail.com DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address. Phone#: Email: CONTRACTOR INFORMATION: Name: Mattituck Heating & Plumbing Corp. Mailing Address: 10680 Main Road PO Box 1429, Mattituck, NY 11952 Phone#: 631-298-8393 Email: bill@ mattituckplumbing.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: DOther House conversion from oil to natural gas $15,200 Will the lot be re-graded? ❑Yes *No Will excess fill be removed from premises? ❑Yes ®No 1 a a PROPERTY INFORMATION Existing use of property: Residential Property Intended use of property: Residential Property Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R40 this property? *Yes ❑No IF YES, PROVIDE A COPY. R Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): ����� yl ��"q V I e c ❑Authorized Agent F*Owner Signature of Applicant: Date: 2� 2- 12.2 CONNIE D.BUNCH STATE OF NEW YORK l Notary Public,State of New York SS: No.01 BU6185050 COUNTY OF ) Qualified in Suffolk County Commission Expires April 14, 2V-,-),3 ......... being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the ........... (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me�this ,r day Of l A t Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I, residing at .................... .do hereby authorize ............................................. _ to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 ",m "mm B"�o A Technical Information ���� H f H In[ertek Standard Equipment • Intelligent Hydronic Control;simple self-diagnostic DOE Net AHRI Approx. control system with 3-digit readout for status settings Heating Rating, Shipping and errors Input Capacity Water Vent Size Weight. • Pre-installed IDL-1200 integral LWCO with auto reset Model (MBH) (MBH) (MBH) AFUE% (Inches) (lbs.) (H-model suffix) X-202 38 32 28 84.0 4 _20i— • 02• Insulated steel jacket X-203 70 59 _ 51 84.0 4 254 • Integrated draft diverter,damper and connector included X-204 105 88 77 84.0 5 304 • Heavy gauge 1"base insulation X-205 140_ 117 102 _ 84.0 6 357_ • Step-opening redundant gas valve X-206 175 146 127 84.0 6 405 • Spark ignition with continuous retry X-207 210 176 153 84.0 7 462 • User-friendly wiring with 120V J-box ......... X_208... 245 205 178 84.0 i 7 518 • Circulator–choice of Taco or Grundfos X-209 28(Fl—234 203 84.0 8 564 • Cast iron section assembly Add suffix"N"for natural gas,or suffix"L"for LP gas models • Resettable blocked vent switch All models certified for use from sea level to 10,000 feet in elevation.Outputs are reduced by 4%per 1,000 feet above sea level for elevations above 2,000 ft. • Boiler drain valve All X-2 boilers are shipped with 30 psi relief valves,MAWP is 50 psi. • Cast iron supply manifold with safety relief valve tapping Width Connections(inches) Water "W" Gas Relief Content Model (inches) Supply Return Valve�Valve (gal.) X-202 14 1-1/4 1-1/4 1/2 3/4 1 NOTES: X-203 1 14 1-1/4 1-1/4 1/2 3/4 2 1.Minimal radial distance around vent pipe and breeching X-204 16 1-1/4 1-1/4 1/2 3/4 3 for single-wall metal pipe vent connector,otherwise follow X-205 19 1-1/4 1-1/4 1/2 3/4 4 vent connector manufacturer's recommended clearances. 2. Add height required to maintain 6"clearance from all X-206 22 1-1/4 1-1/4 1/2 3/4 5 breeching components. X-207 25 1-1/4 1-1/4 3/4 3/4 6 �t X-208 28 1-1/4 1-1/4 _3/4'_'3/4J7 . �n= X-209 31 i-1/4 1-1/4 3/4 3/4 8 MAR �09 ... Min(see Note 1) BUILDING DEPT. TOWN OF SOI1'�k'CLf'D 23"(see Note 2) 33-1/4" 40" 26-3/4" ✓ Return 0 Supply 00 2 _. m..... q 63 " w o o Electrical o Gas 40"" —. 16" 0 �� IIIIIIIIII1110011 � Floor Line Floor Line 0" 13" ................................. 25" 4"�- W ............ �—1„ _.... 31," Form No.USBL15092 10ms 3/20 www.usboiler.net 1r Compare Printed in the U.S.A. ©2020 U.S.Boiler Company,Inc.-Lancaster,PA Lp Phone:1-888-432-8887 COUNTRY CLUB ESTATES PROPERTY OWN ERSO TI 'N/ INC. COVENANTS AND RESTRICTIONS 2018 EDITION REPLACES 1978 EDITION AS WELL AS REVISIONS OF 1988, 1998 &2008 DR MAI2 D E j r EcE [lv D BUILDING DEPT TOWN OF SOUTHOLD COUNTRY CLUB ESTATES DECLARATION OF COVENANTSAND RESTRICTIONS This declaration made this day of November 2018 by COUNTRY CLUB ESTATES PROPERTY OWNERS' ASSOCIATION,INC.,a not-for-profit Corporation having its principal place of business at 315 Country Club Drive,Cutchogue,Suffolk County,New York,as successor in interest to COUNTRY CLUB ESTATES. WITNESSETH: WHEREAS,COUNTRY CLUB ESTATES PROPERTY OWNERS'ASSOCIATION(POA).a partnership, imposed a certain set of Covenants and Restrictions designed to protect property values affecting a certain map of"COUNTRYCLUB ESTATES:a subdivision at Cutchogue.Town of Southold,County of Suffolk and State of New York,filed as Map Number 6736 In the Suffolk County Clerk's office on October 17,1978 and said declaration having been recorded in Liber 8540 CP 510 and dated October 10,1978;and WHEREAS,all the right,title and interest to said Covenants and Restrictions of COUNTRY CLUB ESTATES were assigned to COUNTRY CLUB ESTATES PROPERTY OWNERS'ASSOCIATION,INC.;and WHEREAS,said Covenants and Restrictions were modified by COUNTRY CLUB ESTATES PROPERTY OWNERS'ASSOCIATION,INC.on December 17,1988,again on December 16,1998,again on March 12.2009 and again on November ,2018;and WHEREAS,COUNTRY CLUB ESTATES PROPERTY OWNERS'ASSOCIATION,INC.seeks to again modify and amend said Covenants and Restrictions which shall be binding on all purchasers and mortgagees of individual lots,their heirs.executors,successors and assigns or other successors in interest; NOW THEREFORE,COUNTRY CLUB ESTATES PROPERTY OWNERS'ASSOCIATION,INC.hereby amends and restates in its entiretythe Declaration of Covenants and Restrictions recorded in Liber 8540 CP 510 to read as follows: -1- 1.PROPERTY OWNERS'ASSOCIATION For the purpose of providing such common community services as maybe required or desired within the subdivision for the general use and benefit of all lot owners,each and every lot owner,in accepting a deed or contract for any lot in such premises,agrees to and shall be a member of and subject to the obligations and duly enacted by-laws and rulesofthe COUNTRYCLUB ESTATES PROPERTY OWNERS' ASSOCIATION,a non-profit corporation. 2.BOARD OF ELECTED OFFICERS (a)Whereas the COUNTRY CLUB ESTATES PROPERTY OWNERS'ASSOCIATION,INC.,is a not-for-profit Corporation,its Board of Elected Officers all serve on a one-year voluntarybasis.All officers must be property owners of COUNTRY CLUB ESTATES ASSOCIATION. (b)COUNTRY CLUB ESTATES PROPERTY OWNERS'ASSOCIATION consists of 29 property lots located on Country Club Drive and the west side of Moores Lane in Cutchogue.Each lot owner is entitled to cast one vote for each lot owned for all officer elections and approval of motions at any special or required annual meeting. (c)The required annual meeting of the COUNTRY CLUB ESTATES PROPERTY OWNERS'ASSOCIATION shall be held each year in the month of Novemberwith a date set bythe elected officials.A quorum of 2/3 of property owners is required for a ll meetings. (d)Approval far all officer elections and motions at any meeting of the PROPERTY OWNERS' ASSOCIATION shalt require a 2/3 majority vote of the property owners present. (e)The officer positions wilt be elected at each annual meeting with a 2/3 majority approval of each individual officer by the property owners of the Association. All property owners must be present to cast a vote.The elected officiats titles for the COUNTRYCLUB ESTATES PROPERTYOWNERS' ASSOCIATION are:President.Vice President,Treasurer and Secretary.Each officer serves a one year term but maybe re-elected at the following year's annual meeting. There is no limit to how many terms or positions an officer may serve. (f)An Architectural Review Committee will consist of all current elected officers of the COUNTRY CLUB ESTATES PROPERTY OWNERS'ASSOCIATION and any Past Presidents of the Association currently residing in Country Club Estates. 3.ANNUAL DUES (a)All property owners agree to pay dues to the COUNTRYCLUB ESTATES PROPERTY OWNERS' ASSOCIATION annually by the 3191 of Decemberfor the coming year.A 20%late fee will be applied to all Property owners whose dues arrive after the 3161 of December_This fee will be applied each year to the total amount owed until the entire amount is paid. (b)The cost of dues will be different depending upon whether a property tot is developed or undeveloped. (c)The annual assessment of dues shall be presented and approved atthe POA annual meeting. -2- (d)The purpose of the property dues forthe COUNTRY CLUB ESTATES is as follows: 1.The Town of Southold propertytaxes on the park/marshland area 2. Maintenance/mowing of park area grounds 3. Maintenance of North and South entrance gardens 4. Maintenance and replacement of split rail fencing 5, Cutchogue Post Office mailbox(annual fee) b. COUNTRY CLUB PROPERTY OWNERS'bi-annualpicnic 7. Mowing lawns of all undeveloped properties 6. Office supplies,paper,envelopes,postage,copying,etc. 4. CONSTRUCTION REQUIREMENTS (a)Type of building No building shall be erected,altered,placed orpermitted to remain otherthan one single-family dwelling not to exceed two and one half(21/2)stories in height and a private attached garage'for not less than two(2)nor more than three(3)cars. (b)Accessory buildings No carport or other accessory structure of any kind may be erected except:0)an attached garage,or (2)an accessory shed to house pool and/or garden equipment. Such a structure must blend with the main house and not exceed one hundred(100)square feet in size. (c)Swimming pools Private swimming pools,in-ground only,may be constructed on any lot provided that they are situated In the rear yard only and that no portion of any such pool or its appurtenances be closer to the rear or side lot lines than thirty(30)feet. (d)Dwelling square footage requirements No dwelling shall be permitted on any lot unless the living area,exclusive of open porches and garages, is at least two thousand(2000)square feet for a one-story building or twenty-five hundred(2500) square feet for a two-story structure_ Any exceptions must be approved in writing by the Architectural Review Committee. No dwelling shall exceed four thousand(4000)square feet in total living area without the express written approval of the Architectural Review Committee. -3- (e)Setback requirements Unless shown otherwise by setback lines on the filed map,no part of any building and/or structure, except uncovered steps,stoops,terraces,patios and chimney breasts shall be located on any lot within seventy-five(75)feet of the street line of the lot,nor within thirty-five(35)feet of the sidelines)of the lot,abutting another privately owned building lot,nor within fifty-five(55)feet of the rear line of the lot. In the case of a corner lot,a building shalt be required to comply with the front yard restrictions on one street front only,provided that the width of theyard abutting the street other than that upon which the lot fronts shall be not less than fifty(50)feet.In all cases.front setbacks shall be in general alignment with the front setbacks of neighboring houses. (f)Approval of construction plans The Architectural Review Committee shall preside over and enforce compliancewith all applicable covenants and restrictions.All plans for new buildings,accessory structures,additions,modifications, decks,fences and pools must he submitted to the Committee for approval before construction can proceed.Such approval,which shall be not be unreasonably withheld,shall be based on the judgments of the Committee as to whether the proposed structure will be consistent with,and not detract frgm,the esthetic character of the community. As a guideline,structures should be neo-colonial in design orof such a design to be harmonious therewith.Specifically,structures should be gabled with roofing and siding of traditional materials, brick or stone chimneys,and double-hung or casement windowswith colonial lights or grilles.Any departure from the use of traditional siding and/or roofing materials shall require the approval of the Architectural Committee. (g)Building modifications All permitted accessory structures and additions or other modifications thereto,and any modification of the initial residential Building,including any breezeway or other structure connecting an addition to the main dwelling,shall conform in architecture,material and color to such dwelling. Any attached addition to the initial residential dwelling shall not project more than five(5)feet beyond the front wall of the structure as originally approved.and in no event shall such projection extend beyond the setback requirements set forth above. (h)Construction regulations All exterior construction,painting and grading shalt be completed within one(1)year after beginning construction,which beginning shall be determined by a written notice from the property owner to the Architectural Review Committee. Driveways must be designed so as to accommodate a minimum of four(4)parked cars. During construction or modification of any building and/or structure permitted under paragraphs(f) and(g)above,debris and waste shall be confined to the building site by maintenance of(a)portable toilet facilities for construction workers,(b)cartage disposal containers such as"dumpsters"and(c) barrier fencing such as"snow fence"an the perimeter of the building site. No construction work shall be performed on any Sunday.except work by the owner,nor shall construction work of any nature begin before 7:OOAM on any day of the week -4- 5.RESTRICTION ON DIVISION AND USE OF LOTS No lot shall be subdivided without prior approval of the Southold Town Planning Hoard,Zoning Board of Appeals or other governmental agencies.This provision shall run in perpetuity. 6.RESIDENTIAL USE OF LOTS No lot shall be used except for residential purposes only. 7.SIGNS No sign of any kind shall be displayed to the public view on any lot except signs indicating house number,name of occupant and/or a security company_ &ANIMALS No animals,livestock or poultry of any kind shall be raised.bred or kept on any lot,except that dogs, cats or other household pets are permitted,provided that they are not kept,bred or maintained for any commercial purposes.ALL pets must be housed in the main residence only. 9.TRAILERS,TENTS AND SHACKS (a)No house trailer or motor home shall be located on any lot,except temporarily with the permission of Association officers.No vehicle with commercial registration shall be located on any lot,with the exception of small farm or pickup trucks. No vehicles with commercial signs or logos are permitted on any lot.Lawn tractors,mowers,carts,barrows,mopeds and motorcycles must be garaged.No unlicensed automobiles,or automobiles under repair or dismantled may be stored on any lot unless garaged. (b)No tent.shack or other such structure shall be located an any lot except in accordance with paragraph 4(b)above.Tents for occasional social events are permitted as long as they are taken down within seventy-two(72)hours after the events_Play tents.playhouses and recreational equipment for children are permitted,but must be located in the rear yard.on the ground and must comply with setback requirements. 10.ANNOYING AC71VMES No noxious or offensive activity shall be carried out upon any lot,nor shall anything be done thereon which may be or may become an annoyance to the neighborhood,examples being burning garbage, leaves,tree trunks,etc.or playing of Loud music. Drones may only be operated on the owners property and must be kept below the roof level of the house and not cross onto or fly over anothers property,as this could be considered an invasion of a person's privacy. -5- 11.TRASH No garbage,rubbish or garden waste shall be dumped or allowed to remain on any lot,or in the drainage area,park and wetlands of Country Club Estates.Garbage and refuse for collection must be contained in closed containers,either garaged or shielded from view by low decorative fencing or shrubbery. 12.CLOTHESLINES Clotheslines are forbidden anywhere on the grounds of Country Club Estates property that are viewableto the public and/or neighbors. 13.FENCES Approval must be secured from the Architectural Review Committee with respect to type and placement before installation of any fence. No fence isto exceed four(4)feet in height unless approved by the Architectural Committee. 14.BOATS AND BOATTRAILERS No boats,personal watercraft,snowmobiles or traiters for same shall be stored an any lot unless garaged,nor in the park and wetlands of Country Club Estates. 15.GRADING The elevation or grade of any lot shall not be changed so as to materially affect the surface grade of the surrounding tots. 16.ROAD AND PARI(FACILITIES (a)Surface water drainage system Roads within the subdivision have been constructed in such a manner that the area constructed, sloped,shaped,graded and seeded so as to provide a surface water recharge system for the proper drainage of surface water within such subdivision.in orderto ensure that such drainage system shall function properly,the following covenants and restrictions are hereby imposed upon the area of each lot abutting a road in the subdivision to a distance of twelve(12)feet therefrom(herein referred to as the drainage area),which restrictions shall run in perpetuity. 1. The owner of each lot shat!maintain the drainage area thereon free from leaves,debris and other matter which may impede the flow and/or percolation of surface water over and into the drainage area. 2. No trees,shrubs,plantings or other vegetation except grass shall be planted or maintained in the drainage area without the written consent of the Country Club Estates Property Owners' Association and the Planning Board of the Town of Southold. 3. No sand,gravel,loam or other material shall be deposited in the drainage area.nor shall any material be removed therefrom without the written consent of the Property Owners'Association and the Planning Board of the Town of Southold. 4. No fences or other structures shall be placed or maintained in the drainage area without the written consent of the Property Owners'Association and the Planning Board of the Town of Southold. 5. The Town of Southold shall have the right to enter the drainage area and to construct,maintain, -6- repair and remove such drainage pipes.culverts.catch basins,sumps and other facilities and to perform such excavating,filling,grading and seeding operations as any be deemed necessary for surface drainage purposes. (b)Park and marsh area As indicated on the subdivision map,a park and marsh area has been set aside by the original developer,COUNTRY CLUB ESTATES,for the use of lot owners,their guests and invitees. (c)Use of park and marsh area All owners of lots are hereby granted the right to use the parkand marsh area,in common with others, at their own risk,pursuant to reasonable regulations from time to time promulgated by the Country Club Estates Property Owners'Association. No sanitary facilities shalt be constructed or installed within one hundred(100)feet of the marshland. No structures,duck blinds,backstops,goal posts,basketball,standards,or other fixed athletic equipment are permitted in the park.drainage area or wetlands of Country Club Estates.No boats,boat trailers,mopeds,dirt bikes,motor scooters,motorcycles,house trailers,campers,tents.automobiles or recreational vehicles are permitted in the park,drainage area or wetlands of Country Club Estates. Use of the parkland for special events and community activities is permissible with the approval of the officers of the Association. Each member agrees to comply with any regulations for the use of the park and marsh facilities as may be enacted by the Association. 17.WINDMILLS AND TOWERS No windmill for the purpose of pumping water or producing power,and no towerfor transmitting or receiving radio or television signals shall be located on any lot in Country Club Estates. 18.MAINTENANCE OF ENTRANCE GATES (a)Lots 1,2,3,4,5,6.14 and 29 have had Installed upon them decorative split-rail fence and/or entrance gates by the developer.The purchasers of said lots shall take them subject to same and agree that said fences and/or gates shall not be removed except to provide space necessary for a driveway entrance. (b)The decorative split-ra€t fences along Moores lane,landscaping at the entrances and in the circle on Country Club Drive shall be maintained by the Association. 19.TREES Property owners agree that Honey Locust trees planted on lots fronting Moores Lane and Country Club Drive shall be maintained in good condition and not removed unless damaged or diseased.All trees damaged or destroyed due to disease or weather are expected to be removed in a timely manner by the Individual.lot owner.The Association will assume responsibility in case of damage to the tree in the circle on Country Club Drive and to trees in the park and marsh area. -7- 20.WALKWAYS,DRIVEWAYS.LAWNS AND GARDENS Walkways and driveways must be maintained free and clear of any debris,overgrown-grass and weeds, hazardous material orweather-related damage. All types of damage must be repaired as soon as possible to ensure public safety on walkways and driveways.Lawns and gardens are expected to be kept in a neat,orderly manner.Lawns should be mowed weekly during the growing season.Front yard gardens should be kept free and clear of debris and overgrowing weeds so as to create a clean appealing visual.Excessive statuary in front yards should be kept to a minimum. 21.SNOW REMOVAL Property owners who opt for snow removal,including hiring a private contractor,should be mindful not to Infringe,blockor cause damage to their neighbors'property. 22.UTILITY EASEMENTS An easement along the roads on the map of CountryCtub Estates and over anyother area necessary is hereby expressly reserved for conduits and all proper and necessary attachments for electric, telephone,water,gas and cable television service,provided that such easement shalt be over areas designated by municipal or public authorities. 23.FOREGOING RESTRICTIONS All of the foregoing restrictions are intended to cover onlythe plots shown on the map of Country Club Estates and are not extended to any other property. 24.MODIFICATIONS.TERMINATIONS orANNULMENTS COUNTRY CLUB ESTATES PROPERTY OWNERS ASSOCIATION hereby reserves the right to modify, terminate or annul any of the covenants in whole or part without the consent of any persons. Notwithstanding the provisions of this paragraph 24,the Association may not terminate or annul contraryto the restrictions set forth in paragraph S. 25.COVENANT INVALIDATION Invalidation of any one of these covenants by]udgment or court order shall in no way affect any of the other provisions which shall remain in fullforce and effect. 26.ENFORCEMENT Enforcement shall be by proceedings at law or in equity brought by the COUNTRY CLUB ESTATES PROPERTY OWNERS'ASSOCIATION,or by the ownerof any lot against any person or persons violating or attempting to violate any covenant or restriction,eltherto restrain violation or to recover damages, or both. 27.ENFORCEMENT PROVISIONS Failure of the COUNTRY CLUB ESTATES PROPERTY OWNERS'ASSOCIATION or of any owner to enforce all of the provisions herein shall in no event be deemed a waiver of the right to do so thereafter. -8- Country Club Estates Property Owners'Associations,Inc.Covenants and Restrictions 2MO Edition Prepared and Submitted by the following members: Peter I Harold,President Patricia Rudolph.Vice President Tracy Notan,Treasurer Mark Finnerty,Secretary Barry Grimm,Past President William Aranso,Past President Marty Gleason.Past President -9- .44 1 . "m '" 0 I I 11 I,r,*lII,I,I,. 90I. 80I I count ry kLooll t u [,II q, 1D1rtvI eCutchIag� N w, 11935 AVRIjfC-:r,,_r D �l� 1��-3 - ?,�� fir iEAl,T s_ 'esy 9 ' eI 9 GENERAL NOTES 0� 4 to-70S 1.00 SCOPE AND BASIS OF DESIGN 8.00 INSULATION AND ENERGY COMPLIANCE 1.01 THIS SET COVERS INTERIOR FINISHING OF THE EXISTING UNIFINISHED BASEMENT;ONE(1)NEW EMERGENCY ESCAPE AND RESCUE OPENING WITH WINDOW WELL IN THE RECREATIONAL AREA(WI); 8.01 THE PROPERTY IS IN CLIMATE ZONE 4A.THE WORK CONVERTS UNCONDITIONED BASEMENT SPACE TO CONDITIONED SPACE AND SHALL COMPLY WITH THE 2025 ECCCNYS. REPLACEMENT AND ENLARGEMENT OF THE EXISTING HALLWAY CELLAR WINDOW WITH ANEW WINDOW WELL(W2),WHICH IS NOT AN EMERGENCY ESCAPE AND RESCUE OPENING;AND A DUCTED HEAT 8.02 BASEMENT WALLS,REQUIRED FOR ENERGY COMPLIANCE:INSULATE THE FULL BASEMENT FOUNDATION PERIMETER,INCLUDING THE MECHANICAL/UTILITY ROOM AND STORAGE AREAS,TO R-13 Sc.±.u.NO. aslWT.Loco sccrorv:tog er oc-c:.y Lot(s�.2 16 PUMP SYSTEM SERVING THE FINISHED AREA,DESIGNED AND INSTALLED BY OTHERS.NO OTHER WORK IS INCLUDED OR AUTHORIZED. CAVITY MINIMUM OR R-10 CONTINUOUS,FROM THE TOP OF TILE WALL DOWN TO THE BASEMENT FLOOR SLAB.TYPICAL ASSEMBLY IS 2"XPS OR EPS RIGID FOAM AGAINST THE CONCRETE,2x4 STUDS AT 16" t i O.C.ON A PRESSURE-TREATED BOTTOM PLATE,AND 1/2"GYPSUM BOARD.SEE DETAIL 7/A3.INTERIOR PARTITIONS WITHIN THE BASEMENT SEPARATE CONDITIONED SPACES AND DO NOT REQUIRE , LOT zo 1.02 THE FIRST FLOOR,SECOND FLOOR,ROOF,EXTERIOR WALLS,FOUNDATION,SITE,SEPTIC SYSTEM,DRIVEWAY,POOL,DECKS AND ACCESSORY STRUCTURES ARE EXISTING TO REMAIN,EXCEPT FOR THE INSULATION. I TWO FOUNDATION OPENINGS,THE EXCAVATION,DRAINAGE AND REGRADING REQUIRED FOR THE TWO WINDOW WELLS,AND THE HEAT PUMP OUTDOOR UNIT AND REFRIGERANT LINE-SET PENETRATIONS. 8.03 RIM AND BAND JOISTS WITHIN THE WORK AREA:AIR SEAL AT THE SILL PLATE AND ALL JOINTS AND INSULATE WITH CUT-AND-FIT BAIT INSULATION,R-20 MINIMUM,IN FULL CONTACT WITH THE RIM. t x` ~'-`_5% - x7s^sr5W `. � 249.33 ,b SMOKE AND CARBON MONOXIDE ALARM REQUIREMENTS UNDER SECTION 9.00 APPLY TO THE ENTIRE DWELLING. KRAFT FACING,WHERE USED,SHALL NOT BE LEFT EXPOSED. u'm"/r OF - _ Q row«or s-m •' .;':::.':•;;•::;;•:;.: / __ . t D� - KRAFT-FA ED BAIT AT SOFFITED AREAS AND R-38 KHtAFT-FACED BATT AT NON SOFFITED AREAS INSTALLED BETWEEN THE __8.04 BASEMENT CEILING,OWNER-ELECTED:R 30 C EXISTING FLOOR JOISTS AT THE ..: '' 1.03 THE FINISHED BASEMENT CONSISTS OF THE MAIN AREA,THE RECREATIONAL AREA,TWO WALK-IN CLOSETS(WIC 1 AND WIC 2),AND A MECHANICAL/UTILITY ROOM WITH STORAGE CONTAINING THE OWNER'S DIRECTION.THE BASEMENT CEILING SEPARATES TWO CONDITIONED SPACES.INSULATION THERE IS NOT REQUIRED BY THE ECCCNYS,IS NOT PART OF THE ENERGY COMPLIANCE PATH FOR THIS t\ I \i :�° I � I nmrMo I '..sartr a t BOILER,WATER HEATER AND AIR HANDLER.THE MAIN AREA AND RECREATIONAL AREA ARE OPEN AREAS WITHOUT DOORS.WIC 1 AND WIC 2 ARE STORAGE CLOSETS ACCESSED FROM THE FINISHED AREA. PROJECT,AND NO THERMAL OR ACOUSTIC PERFORMANCE IS REPRESENTED.FACING SHALL BE INSTALLED IN CONTACT WITH THE GYPSUM BOARD CEILING AND SHALL NOT BE LEFT EXPOSED.BAITS SHALL �,., ,Sp .,•' +'�mer t 'a,7 �3��.. > R,»+. � t DOORS OCCUR ONLY AT THE TWO CLOSETS AND THE TWO DOORS TO THE MECHANICAL ROOM.NO SLEEPING ROOMS AND NO PLUMBING FIXTURES ARE PROPOSED.NO ROOM SHOWN ON THIS SET SHALL BE NOT BE FORCED INTO THE CAVITY IN A WAY THAT DISPLACES THE CEILING PLANE OR BLOCKS CLEARANCES AT DUCTS,PIPING,WIRING OR FIXTURES. .W-_..w` °," ti � � / -_�r ` I � s� N ,*"ww I / USED AS A SLEEPING ROOM.CREATING A SLEEPING ROOM OR ADDING A PLUMBING FIXTURE REQUIRES AMENDED FILINGS AND MAY REQUIRE SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES REVIEW, 8.05 NO INSULATION IS REQUIRED UNDER THE EXISTING BELOW-GRADE SLAB. \ I r` .°`°hat °ar- -- /� j AND SHALL NOT BE PERFORMED UNDER THESE DRAWINGS. 8.06 DO NOT INSTALL A POLYETHYLENE VAPOR RETARDER ON THE INTERIOR FACE OF BELOW-GRADE:WALLS.INSTALL INSULATION USED FOR ENERGY COMPLIANCE TO ITS FULL RATED R-VALUE WITHOUT �n I 1 _ /VlmTm .-,, 1 COMPRESSION,GAPS,VOIDS OR MISALIGNMENT,IN FULL CONTACT WITH THE AIR BARRIER,AND PER THE MANUFACTURER'S INSTRUCTIONS.WHERE CAVITY DEPTH CANNOT ACCOMMODATE THE PRODUCT , �I f I �w f \\ 1 S � 1.04 NO INCREASE IN BUILDING AREA,BUILDING HEIGHT,LOT COVERAGE,BEDROOM COUNT OR NUMBER OF DWELLING UNITS IS PROPOSED.THE DWELLING REMAINS AONE-FAMILY DWELLING. SELECTED,NOTIFY THE ENGINEER BEFORE INSTALLATION. ;, I # t ` t �; ; �I rm 7 u"a tv cv 1 7 8.07 PROVIDE A CONTINUOUS AIR BARRIER,SEALED AT ALL JOINTS,PENETRATIONS AND TRANSITIONS,INCLUDING AROUND THE NEW WINDOW BUCKS AND THE REFRIGERANT LINE-SET PENETRATIONS. CrAWRr clue csA•rs I I * tr I I R y VRpV[RFf OwhCRs V+C ' I I / I ►�. 1.05 AN AMENDED CERTIFICATE OF OCCUPANCY REFLECTING TV lE FINISHED BASEMENT IS REQUIRED BEFORE THE FINISHED SPACE IS OCCUPIED. f t oma r 11°r I 8.08 NEW PERMANENT LIGHTING SHALL BE HIGH-EFFICACY.RECESSED FIXTURES SHALL BE IC-RATED AND AIRTIGHT.SEAL THE JOINTS OF ANY DUCT THAT IS ALTERED. t 9�1 f - I t '•� 2.00 CODE BASIS "°" "aim i i Mm j I �V.v l"- II t 11 (� 2.01 ALL WORK SHALL CONFORM TO THE.2025 UNIFORM CODE OF NEW YORK STATE,EFFECTIVE DECEMBER 31,2025,CONSISTING OF THE 2025 RESIDENTIAL CODE OF NEW YORK STATE(RCNYS),THE 2025 8.09 THE ENGINEER'S ENERGY DOCUMENTATION ADDRESSES THE PROPOSED WORK ONLY.NO REPRESENTATION IS MADE REGARDING THE ENERGY PERFORMANCE OR AIR LEAKAGE RATE OF THE EXISTING __ � -s a.' i I °' '° :" � Io1'9' \ t ... t t"" ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK S7TATE(ECCCNYS),THE 2025 FIRE CODE OF NEW YORK STATE WHERE APPLICABLE,AND THE 2025 EXISTING BUILDING CODE OF NEW YORK STATE DWELLING OUTSIDE THE WORK AREA.TESTING REQUIRED BY THE CODE OFFICIAL SHALL BE ARRANGH D AND PAID FOR BY THE OWNER OR CONTRACTOR. „� , , , /, I :;;_ 1 ,h.«, ,i ► t C n.ee o N co[I.�..ollww c srw . r - --1;, 1 pw I I � b WHERE APPLICABLE TO ALTERATION OF AN EXISTING DWELLING.WORK SHALL ALSO CONFORM TO NFPA 70 AS ADOPTED AND TO THE CODE OF THE TOWN OF SOUTHOLD.SECTION REFERENCES ON THESE P .s. I I ;c.+s c t .n... I / DRAWINGS ARE TO THE 2025 RCNYS. 8.10 ENERGY CODE COMPLIANCE STATEMENT:TO THE BEST OF MY KNOWLEDGE,BELIEF AND PROFESSIONAL JUDGMENT,THESE PLANS AND SPECIFICATIONS ARE IN COMPLIANCE WITH THE 2025 ENERGY -../ � t t ` t 11 1. - I . / a;j CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE. - k I , t ;;;r t I I t� Q�`o t � 2.02 WHERE THESE DRAWINGS AND THE APPLICABLE CODES CONFLICT,THE MORE STRINGENT REQUIREMENT GOVERNS.THE CONTRACTOR SHALL NOTIFY THE ENGINEER IN WRITING OF ANY CONFLICT I \I I - t '' I 1 � 1 "•0 b '" Q f 5' ;;-F; I I - I I-**" BEFORE PROCEEDING WITH THE AFFECTED WORK. 9.00 SMOKE AND CARBON MONOXIDE ALARMS `` E t^�.,3�00'�cn3Acr<-.r �il I ,;{; - I t „� I w i.m. 0 ';,- 9.01 SMOKE ALARMS SHALL BE PROVIDED PER R310 AND CARBON MONOXIDE ALARMS PER R311 AND'THE FIRE CODE OF NEW YORK STATE THROUGHOUT THE ENTIRE DWELLING,NOT ONLY WITHIN THE ♦ �. @@ ` 7 f II I� �. ;;;e WORK AREA.ALTERATION UNDER A BUILDING PERMIT TRIGGERS THIS REQUIREMENT FOR THE EXISTING DWELLING.SMOKE ALARMS:IN THE BASEMENT,IN EACH SLEEPING ROOM,OUTSIDE EACH SEPARATE I I I, I I I = I \u r, - A Proxima°locatbn N �°. ""� 2.03 NOTHING SHOWN OR NOTED SHALL BE CONSTRUED AS PER:M[TTING WORK THAT DOES NOT CONFORM TO THE APPLICABLE CODES. Q SLEEPING AREA,AND ON EACH STORY.CARBON MONOXIDE ALARMS:OUTSIDE EACH SEPARATE SLEEPING AREA,ON EACH STORY,AND IN THE BASEMENT,WHICH CONTAINS FUEL-BURNING APPLIANCES. I I S__ I I I a I o'' t --51 rn Egws wmdo w s wel 3.00 EXISTING CONDITIONS AND FIELD MEASUREMENTS z r, s tas'I I``"`s I I bo I `" t of o. ur , \ $ 3.01 EXISTING DIMENSIONS AND CONDITIONS WERE FIELD MEASURED BY THE ENGINEER ON SEPTEMBER 13,2026,AND REFLECT CONDITIONS VISIBLE AND ACCESSIBLE ON THAT DATE.FRAMING,SPAN AND 9.02 NO WORK IS PROPOSED ON THE FIRST OR SECOND FLOOR,AND NO PLANS OF THOSE FLOORS ARE]INCLUDED IN THIS SET.THE OWNER SHALL VERIFY THAT SMOKE AND CARBON MONOXIDE ALARMS . �°,,I -I�- / ,t2 .,a h:.:;. 1 1 Q 1 txarr a 1.•roa it"m I / FOOTING INFORMATION IS TAKEN FROM THE ORIGINAL FOUNDATION PLAN DATED 1986 AND HAS NOT BEEN INDEPENDENTLY VERIFIED. THROUGHOUT THE EXISTING DWELLING ARE PRESENT,CORRECTLY LOCATED,OPERATIONAL AND WIUHIN THEIR SERVICE LIFE,AND SHALL ADD OR REPLACE UNITS AS REQUIRED TO SATISFY R310 AND R311. 1" I / 000gu - .x "6ti I NEW ALARMS IN THE BASEMENT SHALL BE HARD-WIRED WITH BATTERY BACKUP AND INTERCONNEC7TED.IN EXISTING AREAS WHERE WALL AND CEILING FINISHES ARE NOT REMOVED,LISTED a '' ./' t "°-% I I .a. 11 3.02 THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS,ELEVAiTIONS AND EXISTING CONDITIONS IN THE FIELD BEFORE ORDERING MATERIALS,FABRICATING ANY ASSEMBLY OR STARTING WORK.DO NOT WIRELESS-INTERCONNECTED ALARMS OR LISTED 10-YEAR SEALED-BATTERY ALARMS ARE ACCEPTABLE.COMBINATION SMOKE AND CARBON MONOXI DF.UNITS ARE ACCEPTABLE.ALARM WORK IS Sze W W / � / SCALE THESE DRAWINGS. PERFORMED BY THE OWNER'S LICENSED ELECTRICIAN UNDER THE SEPARATE ELECTRICAL PERMIT. 3.03 NO DESTRUCTIVE INVESTIGATION,PROBING,TESTING,OPETNING OF FINISHES OR EXCAVATION WAS PERFORMED.CONCEALED CONDITIONS WERE NOT OBSERVED AND ARE NOT REPRESENTED.NO 9.03 BASEMENT ALARM LOCATIONS ARE SHOWN ON THE PROPOSED BASEMENT PLAN.MOUNT PER DETAIL 6/A3.KEEP ALARMS NOT LESS THAN 3 FT FROM HVAC SUPPLY REGISTERS AND RETURN GRILLES, SITE MAP REPRESENTATION IS MADE AS TO THE ADEQUACY OF ANY EXISTING STRUCTURAL,MECHANICAL,PLUMBING OR ELECTRICAL ELEMENT NOT EXPRESSLY ANALYZED AND SO NOTED. AND OUTSIDE THE MECHANICAL ROOM. 3.04 WHERE CONDITIONS DIFFER FROM THOSE SHOWN OR ASSUTMED,THE CONTRACTOR SHALL STOP WORK IN THE AFFECTED AREA AND NOTIFY THE ENGINEER IN WRITING BEFORE PROCEEDING. 10.00 ELECTRICAL,BY OTHERS 10.01 NO ELECTRICAL DESIGN,LAYOUT,LOAD CALCULATION,PANEL SCHEDULE,CIRCUITING OR LIGHTING DESIGN IS PROVIDED BY THE ENGINEER,AND NONE IS INCLUDED IN THIS SET.ALL ELECTRICAL 3.05 THE ENGINEER HAS RELIED ON THE SURVEY AND OTHER DOCUMENTS FURNISHED BY THE OWNER OR PREPARED BY OTHERS AND IS NOT RESPONSIBLE FOR THEIR ACCURACY OR COMPLETENESS. WORK SHALL BE DESIGNED,PERFORMED,PERMITTED AND CERTIFIED BY A LICENSED ELECTRICIAN RETAINED BY THE-,OWNER,IN ACCORDANCE WITH NFPA 70 AS ADOPTED AND RCNYS CHAPTERS 34 THROUGH 43.THE ELECTRICIAN IS RESPONSIBLE FOR ARC-FAULT AND GROUND-FAULT PROTECTION,RECEPTACLE AND LIGHTING OUTLET SPACING,THREE-WAY SWITCHING AT THE STAIR,A SWITCHED 3.06 ALL FRAMING,INSULATION AND FINISH WORK SHOWN ON 71'HIS SET IS NEW WORK UNDER THIS PERMIT.ANY FRAMING IN PLACE AT THE START OF CONSTRUCTION SHALL BE VERIFIED AGAINST THESE LIGHT AND SERVICE RECEPTACLE AT THE MECHANICAL EQUIPMENT,STAIRWAY AND EGRESS ILLUMIMATION,HVAC EQUIPMENT CIRCUITS AND DISCONNECTS,WORKING CLEARANCE AT THE PANEL,AND DRAWINGS AND THE APPLICABLE CODES AND SHALL BE CORRECTED,MODIFIED OR REMOVED AS REQUIRED TO CONFORM.NO WORK SHALL BE CONCEALED BEFORE THE REQUIRED INSPECTIONS ARE PANEL CAPACITY. L r' ' �• (r-, R r COMPLETED AND APPROVED. : �'% L,, ur l , f x,-,, 10.02 ELECTRICAL WORK IS PERMITTED AND INSPECTED SEPARATELY.THE OWNER SHALL OBTAIN ANI ELECTRICAL CERTIFICATE FROM AN APPROVED INSPECTION AGENCY.IT IS REQUIRED BEFORE THE �' L� ,I+ 1 4.00 CEILING HEIGHT CERTIFICATE OF OCCUPANCY IS ISSUED. - t 4.01 CEILING HEIGHTS COMPLY WITH R313.1.HABITABLE SPACE:AND HALLWAYS HAVE A CLEAR HEIGHT OF NOT LESS THAN T-0".BEAMS,DUCTS,PIPING AND SIMILAR OBSTRUCTIONS PROTECT NO LOWER 4 30 1 I r : THAN 6'4"ABOVE THE FINISHED FLOOR,AS PERMITTED IN BASEIMENTS. 10.03 THE ADEQUACY OF THE EXISTING ELECTRICAL SERVICE AND PANEL TO CARRY THE ADDED LOAD HAS NOT BEEN EVALUATED BY THE ENGINEER AND IS THE RESPONSIBILITY OF THE OWNER'S oG'r I Q - , LICENSED ELECTRICIAN. I 2rr A I r #� ' 4.02 FIELD-MEASURED SLAB TO TOP OF FOUNDATION WALL IS 7r'-7"(91").FIELD-MEASURED SLAB TO UNDERSIDE OF EXISTING 2xl0 FLOOR JOISTS IS APPROXIMATELY T-8 1/2"(92 1/2").THE CEILING IS FRAMED /+d 3 WITH 2x4 MEMBERS ON EDGE FASTENED BELOW THE JOISTS(3-1/12"DROP)WITH 1/2"GYPSUM BOARD,GIVING A FINISHED CEILING AT APPROXIMATELY 88-1/2"ABOVE THE SLAB.PROPOSED FINISHED CLEAR 11.00 MECHANICAL Or1. ._, HEIGHTS ARE BASED ON 1/2"FINISHED FLOORING OVER UNDERLAYMENT: 11.01 THE DWELLING IS SERVED BY NATURAL GAS.THE MECHANICAL ROOM CONTAINS A GAS-FIRED BOILER AND A GAS-FIRED STORAGE WATER HEATER,BOTH VENTED TO THE EXISTING CHIMNEY AND - - - -' I A. FINISHED ROOMS,CLEAR OF SOFFITS:88-1/2"ABOVE EXISFING SLAB;7'4"FINISHED CLEAR HEIGHT;T-0"REQUIRED. FLUES.THE EXISTING AIR HANDLER AND FILTER,LOCATED WITHIN THE MECHANICAL ROOM,ARE EXISTING TO REMAIN.A NEW DUCTED HEAT PUMP FAN COIL SERVING THE FINISHED AREA IS LOCATED B. UNDERSIDE OF SOFFITS AT DUCTS,BEAMS AND PIPING:801"MINIMUM ABOVE EXISTING SLAB;6-7 1/2"MINIMUM FINISHED CLEAR HEIGHT;64"REQUIRED. WITHIN THE MECHANICAL ROOM,ADJACENT TO THE EXISTING AIR HANDLER;SEE 11.07. C. MECHANICAL ROOM,STORAGE AND CLOSETS:AS EXISITMG;6-8"MINIMUM FINISHED CLEAR HEIGHT;6-8"REQUIRED,64"AT OBSTRUCTIONS. - 11.02 MAINTAIN THE MANUFACTURER'S LISTED CLEARANCES TO COMBUSTIBLES,A LEVEL WORKING'SPACE OF NOT LESS TI IAN 30"x 30"AT THE CONTROL SIDE OF EACH APPLIANCE,AND A DOOR OR 4.03 SOFFITS ENCLOSE EXISTING DUCTWORK,PIPING AND STRUCTURAL MEMBERS ONLY.SOFFIT LOCATIONS AND CLEAR HEIGHTS ARE SHOWN ON THE PROPOSED BASEMENT PLAN. PASSAGE LARGE ENOUGH TO REMOVE THE LARGEST APPLIANCE.NO APPLIANCE SHALL BE ENCLOSED,SUCH THAT SERVICING OR REMOVAL REQUIRES DISMANTLING PERMANENT CONSTRUCTION. 4.04 CLEAR HEIGHTS SHALL NOT BE REDUCED BELOW THOSE SHOWN.ADDED FURRING,DROPPED CEILINGS,RECESSED FIXTURES,DUCTWORK,PIPING OR FLOORING BUILD-UP THAT WOULD REDUCE A 11.03 FIRE SEPARATION OF THE MECHANICAL ROOM IS PER NOTE,7.05 AND DETAIL 5/A3. I I I • - CLEAR HEIGHT REQUIRES THE ENGINEER'S PRIOR WRITTEN APPROVAL. 11.04 COMBUSTION AND VENTILATION AIR FOR THE FUEL-FIRED APPLIANCES SHALL BE PROVIDED FROM OUTDOORS IN ACCORDANCE WITH RCNYS CHAPTER 17 AND G2407.BECAUSE THE MECHANICAL . 5.00 STRUCTURAL:FOUNDATION OPENINGS AND HEADERS ROOM ENCLOSURE IS RATED,NO COMBUSTION AIR OPENINGS,LOUVERS OR TRANSFER GRILLES SIIALIL BE PROVIDED BETWEEN THE MECHANICAL ROOM AND THE FINISHED AREA.OUTDOOR AIR OPENINGS 5.01 DESIGN CRITERIA: OR DUCTS SHALL BE SIZED BY THE MECHANICAL CONTRACTOR ON THE TOTAL INPUT OF ALL GAS APPLLIANCES IN THE ROOM. - 3' A. GROUND SNOW LOAD,PG:20 PSF. #1580 0% . B. ULTIMATE DESIGN WIND SPEED,VULT:130 MPH,EXPOSURE B. 11.05 NO RETURN AIR SHALL BETAKEN FROM ANY ROOM CONTAINING A FUEL-BURNING APPLIANCE.'THE EXISTING AIR HANDLER AND THE NEW HEAT PUMP FAN COIL,BOTH LOCATED WITHIN THE - - w C. SEISMIC DESIGN CATEGORY:B. MECHANICAL ROOM,SHALL HAVE THEIR RETURNS FULLY DUCTED FROM OUTSIDE THE MECHANICAL]ROOM,WITH CABINETS,PLENUMS AND ALL DUCT JOINTS WITHIN THE ROOM SEALED,SO THAT THE ti D. FROST LINE DEPTH:36". EQUIPMENT DOES NOT DEPRESSURIZE THE ROOM OR AFFECT THE VENTING OF THE GAS APPLIANCES. E. FLOOR LIVE LOAD:40 PSF FIRST FLOOR;30 PSF SECOND FLOOR(SLEEPING ROOMS).FLOOR DEAD LOAD: 10 PSF. I , F. ROOF DEAD LOAD: 12 PSF;ROOF LIVE/SNOW LOAD:20 PSIF.ATTIC CEILING: 10 PSF DEAD,10 PSF LIVE(UNINHABITABLE,ATTIC WITHOUT STORAGE). 11.06 NO EXISTING APPLIANCE,FLUE,VENT,CHIMNEY CLEANOUT,GAS SHUTOFF,DUCT OR COMBUSTION AIR OPENING SHALL BE ENCLOSED,OBSTRUCTED,REDUCED OR RELOCATED IN A MANNER THAT - ` ' , G. EXTERIOR WALL ABOVE FOUNDATION:WOOD-FRAMED WITH CEDAR SIDING,10 PSF.NO BRICK VENEER. REDUCES REQUIRED CLEARANCE,ACCESS,COMBUSTION AIR OR VENTING CAPACITY.PROVIDE ACCESS PANELS AT VALVES,DAMPERS,CLEANOUTS AND JUNCTION BOXES. Country ClubD' . H. EXISTING WALL AT BOTH OPENINGS:8"CAST-IN-PLACE CONCRETE WITH AN EXISTING 4"EXTERIOR BRICK SHELF(NO BRICK)WHERE IT OCCURS;F'C ASSUMED 2,500 PSI,NOT TESTED 1. TYPICAL FOUNDATION ELSEWHERE:8"CAST-IN-PLACE CONCRETE ON 16"x 8"CONCRETE FOOTING,PER 1986 PLAN. 11.07 HEATING AND COOLING OF THE FINISHED AREA SHALL BE PROVIDED BY A DUCTED HEAT PUMP'SYSTEM,INCLUDED UNDER THIS BUILDING PERMIT:ONE OUTDOOR HEAT PUMP AND ONE DUCTED FAN , J. EXISTING FRAMING ABOVE:2x10 FLOOR JOISTS AT 12"O.C;.,15'-2"SPAN,BRIDGING AT MIDSPAN,RUNNING PARALLEL TO THE FRONT WALL AND BEARING ON THE INTERIOR GIRDER. COIL LOCATED IN THE MECHANICAL ROOM ADJACENT TO THE EXISTING AIR HANDLER,WITH SUPPLY IDUCTS TO ONE SUPPLY REGISTER IN THE RECREATIONAL AREA AND ONE IN THE MAIN AREA AND A ' K. WOOD HEADERS:PRESSURE-TREATED SOUTHERN PINE NO..1(GRADE-STAMPED),KILN-DRIED AFTER TREATMENT(KDAT),NOT INCISED.NDS 2018 ASD,DRY SERVICE:FB=1,350 PSI(2X6),FV=175 PSI, DUCTED RETURN FROM THE FINISHED AREA.NO WALL-MOUNTED INDOOR UNITS ARE PROPOSED.THE!SYSTEM IS NOT DESIGNED BY THE ENGINEER.EQUIPMENT SELECTION,SIZING(ACCA MANUAL J AND FC-PERP=565 PSI,E=1,600,000 PSI;REPETITIVE-MEMBER FACTOR CR=1.15 FOR THE 3-PLY NAILED HEADER. MANUAL S),DUCT DESIGN(ACCA MANUAL D),REGISTER AND GRILLE LOCATIONS,CONTROLS,REFRIGEERANT PIPING,CONDENSATE DISPOSAL AND INSTALLATION SHALL BE BY THE OWNER'S LICENSED HVAC 5.02 HEADER DESIGN IS SUMMARIZED IN THE HEADER CHECK SUMMARY ON SHEET A2.GOVERNING RATIO 0.94(WI HEADER BENDING);DEFLECTION L/558 TOTAL AND L/1,I 11 LIVE AGAINST L/240 AND L/360 CONTRACTOR,PER THE MANUFACTURER'S INSTRUCTIONS,THE MECHANICAL PROVISIONS OF THE RCNYYS AND THE ECCCNYS.THE SYSTEM PROPOSED BY THE OWNER'S CONTRACTOR IS A MITSUBISHI , LIMITS. M-SERIES DUCTED FAN COIL WITH MATCHING OUTDOOR HEAT PUMP,CURRENT MODEL,18,000 BTU/H N10MINAL;FINAL MODEL AND CAPACITY BY THE CONTRACTOR. " . 5.03 HEADERS:AT EACH OPENING,(3)2X6 PRESSURE-TREATED SOUTHERN PINE NO.1 HEADER,SET TIGHT TO THE UNDERSIDE OF THE EXISTING SILL PLATE,ON(1)PT 2X6 JACK EACH SIDE BEARING ON A PT 2X8 SILL THAT RUNS THE FULL WIDTH OF THE CUT.THE HEADEW SHALL BEAR ON THE FULL 4-1/2"WIDTH OF EACH JACK.HEADER AND JACKS MAY BE SET FLUSH TO EITHER FACE OF THE WALL TO SUIT THE 11.08 LIGHT,VENTILATION AND HEATING SHALL COMPLY WITH R325.WHERE NATURAL LIGHT AND VENTILATION ARE,NOT PROVIDED,ARTIFICIAL LIGHT AND MECHANICAL VENTILATION SHALL BE WINDOW INSTALLATION;FILL THE REMAINING WALL THICKNESS WITH PT 2X FILLER.NAIL HEADER PLIES WITH 16D HOT-DIP GALVANIZED NAILS,2 ROWS AT 12"O.C.EACH PLY,STAGGERED.NO.2 GRADE PROVIDED TO THE EXTENT REQUIRED BY THAT SECTION.A DEHUMIDIFIER WITH A ROUTED CONDENSATE DISCHARGE IS RECOMMENDED. LUMBER SHALL NOT BE SUBSTITUTED FOR THE HEADER.SEE DETAIL 3/A3. , 5.04 OPENINGS:W 1 CUT 54"WIDE BY 55-1/2"HIGH,FROM ELEVATLION 35-1/2"TO THE UNDERSIDE OF THE SILL PLATE(91");ROUGH OPENING 51"X 48-1/2".W2 CUT 46"WIDE BY 38-1/2"HIGH,FROM ELEVATION 11.09 THE CAPACITY,CONDITION AND CODE COMPLIANCE OF THE EXISTING HEATING SYSTEM HAVE N40T BEEN EVALUATED BY THE ENGINEER.REPLACEMENT OR MAJOR MODIFICATION OF THE EXISTING 52-1/2"TO THE UNDERSIDE OF THE SILL PLATE;ROUGH OPENING 43"X 31-1/2";THE NEW W2 HEAD IS 5-1/2"BELOW THE EXISTING HEAD.THE DESIGN IS VALID ONLY FOR CUTS NOT WIDER THAN SHOWN.ANY SYSTEM IS OUTSIDE THIS SCOPE. r , CHANGE IN OPENING WIDTH,}LEADER SIZE,LUMBER GRADE OR ILOAD PATH REQUIRES THE ENGINEER TO RE-CHECK THE HEADER. 11.10 DUCTWORK SHALL BE SEALED AND INSULATED PER THE ECCCNYS AND KEPT WITHIN CONDITIOPNED SPACE,IN SOFFITS OR BETWEEN JOISTS.WHERE THE SUPPLY OR RETURN DUCTS OR REFRIGERANT I" 5.05 AN ALTERNATE HEADER PROPOSED BY THE EGRESS CONTRACTOR MAY BE SUBMITTED TO THE ENGINEER WITH SIZE,SPECIES,GRADE,BEARING AND ANCHORAGE.NO ALTERNATE SHALL BE INSTALLED PIPING PENETRATE THE.P2 MECHANICAL ROOM WALLS OR CEILING,USE STEEL DUCT AND SEAL THE AINNULAR SPACE WITH A LISTED FIRESTOP SYSTEM;PROVIDE FIRE DAMPERS WHERE REQUIRED BY THE WITHOUT THE ENGINEER'S WRITTEN APPROVAL. CODE OFFICIAL.MAINTAIN FIREBLOCKING AT SOFFITS AROUND DUCTS. . 5.06 THE 8"WALL THICKNESS IS TAKEN FROM THE 1986 FOUNDATION PLAN.VERIFY THE ACTUAL THICKNESS,MATERIAL AND CONDITION AT EACH OPENING BEFORE CUTTING.WHERE THE WALL IS THICKER 11.11 THE PROPOSED EQUIPMENT USES R454B(A2L)REFRIGERANT.INSTALL PER THE MANUFACTURERZ,UL 60335-2-40 AND THE A21,REFRIGERANT PROVISIONS OF THE RCNYS,INCLUDING ANY REFRIGERANT THAN 8",EXTEND THE PT FILLER TO THE FULL WALL THICKNESS;THE HEADER IS UNCHANGED.WHERE THE EXISTING 4"BRICK SHELF OCCURS AT AN OPENING,CUT THROUGH THE FULL WALL THICKNESS.IF DETECTION OR MITIGATION REQUIRED FOR THE SIZE OF THE ROOM IN WHICH THE INDOOR UNIT IS INSITALLED. THE WALL PROVES TO BE CONCRETE MASONRY,STOP WORK AND NOTIFY THE ENGINEER;THE HEADER DESIGN DOES NOT APPLY TO A MASONRY WALL. 11.12 SET THE OUTDOOR UNIT ON A PRE-CAST PAD WITH THE MANUFACTURER'S CLEARANCES AT THE;LOCATION SHOWN ON THE SITE KEY PLAN,CLEAR OF TI IE WINDOW WELLS AND THE EGRESS PATH. . 5.07 CUTTING REQUIREMENTS: SLEEVE AND SEAL LINE-SET PENETRATIONS ABOVE GRADE.PROVIDE 30"x 30"LEVEL WORKING SPACE AND SERVICE ACCESS AT THE FAN COIL WITHOUT BLOCKING ACCESS TO THE EXISTING WELL A. CUT WITH A WET DIAMOND SAW.JA.CKHAMMERING AND IIMPACT DEMOLITION ARE NOT PERMITTED. EQUIPMENT,BOILER,WATER HEATER,AIR HANDLER OR ELECTRICAL PANEL.ROUTE CONDENSATE TO'THE EXISTING FLOOR DRAIN OR TO A CONDENSATE PUMP DISCHARGING TO AN APPROVED LOCATION. B. CORE-DRILL THE CORNERS,OR STOP THE SAW CUTS AT THE CORNERS.DO NOT OVERCUT PAST A CORNER.CUT TO THE UNDERSIDE OF THE EXISTING SILL PLATE OVER THE OPENING WIDTH ONLY. DUCTS,REGISTERS AND GRILLES SHALL NOT OBSTRUCT THE W I EGRESS WINDOW OR REDUCE CEILING HEIGHTS BELOW THOSE IN NOTE 4.02. C. IMMEDIATELY AFTER CUTTING,APPLY THE MEMBRANE TO THE CONCRETE CONTACT SURFACES,SET THE PT SILL ON THE CONCRETE,SET THE JACKS ON THE SILL,AND SET THE HEADER.SHIM THE HEADER TIGHT TO THE SILL PLATE WITH PT HARDWOOD SHIMS(OR NON-SHRINK GROUT,WITH NO GAPS,AND INSTALL ALL FASTENERS PER NOTE 5.13 AND DETAIL 3/A3 BEFORE THE SHORING IS REMOVED. 12.00 PLUMBING 12.01 NO BATHROOM,TOILET ROOM,WET BAR,SINK,LAUNDRY,EJECTOR PUMP OR OTHER PLUMBING]FIXTURE IS PROPOSED,AND NO PLUMBING DESIGN IS PROVIDED.ADDING ANY PLUMBING FIXTURE IS 5.08 NO CUTTING SHALL BEGIN UNTIL TEMPORARY SHORING OF-THE FIRST-FLOOR FRAMING IS IN PLACE.TEMPORARY SHORING,BRACING,EXCAVATION SUPPORT AND THE MEANS AND METHODS OF OUTSIDE THIS SCOPE,REQUIRES AMENDED FILINGS,AND MAY REQUIRE SUFFOLK COUNTY DEPARTMENT OF I IALTH SERVICES REVIEW. INSTALLATION ARE THE CONTRACTOR'S SOLE RESPONSIBILITY AND ARE NOT DESIGNED BY THE ENGINEER.KEEP THE SHORING IN PLACE UNTIL THE HEADER IS SHIMMED TIGHT TO THE SILL PLATE AND ALL HEADER,JACK,SILL AND SILL-PLATE FASTENERS ARE INSTALLED. 12.02 PROTECT EXISTING PIPING,THE WASTE LINE,THE FLOOR DRAIN AND ANY SUMP.PROVIDE ACCESS PANELS AT EXISTING CLEANOUTS.NO EXISTING PLUMBING SHALL BE RELOCATED,REDUCED OR CAPPED WITHOUT A SEPARATE PERMIT AND THE ENGINEER'S PRIOR WRITTEN APPROVAL. OWNER: HAKAN ERGULEC 5.09 W2:THE EXISTING 30"X22"WINDOW IS REMOVED AND REPLACED.CUT THE ENLARGED OPENING TO THE UNDERSIDE OF THE SILL PLATE AND INSTALL THE HEADER PER NOTE 5.03.THE NEW HEAD (UNDERSIDE OF THE HEADER)IS 5-1/2"BELOW THE EXISTING HEAD,WHICH IS ASSUMED AT THE TOP OF THE WALL,EL.91";VERIFY IN THE FIELD. 13.00 MOISTURE,WATER INTRUSION AND HAZARDOUS MATERIALS SCTM NO.: 1000-1 09.00-03.00-002.016 5.10 AT EXCAVATION,VERIFY THE LOCATION OF THE FIRST-FLO)OR WINDOWS ABOVE WI AND W2.IF A JAMB OF A WINDOW ABOVE FALLS WITHIN A HEADER SPAN,NOTIFY THE ENGINEER. 13.01 NO MOISTURE SURVEY,WATER INTRUSION INVESTIGATION,RADON TEST,MOLD ASSESSMENT,ASBESTOS SURVEYOR LEAD SURVEY WAS PERFORMED,AND NONE IS INCLUDED.THESE DRAWINGS JURISDICTION: TOWN OF SOUTHOLD, SUFFOLK COUNTY MAKE NO REPRESENTATION AS TO THE PRESENCE OR ABSENCE OF THESE CONDITIONS. ZONING DISTRICT:R-40 RESIDENTIAL 5.11 BEFORE EXCAVATING,LOCATE AND PROTECT EXISTING UTILITIES,IRRIGATION,DRY-WELLS,SEPTIC TANK,LEACHING POOLS AND SEPTIC VENT,GAS SERVICE,THE GENERATOR AND ITS FEEDS,AND THE OCCUPANCY/CONSTRUCTION:ONE-FAMILY DWELLING RCNYS /TYPE VB HEAT PUMP REFRIGERANT LINE SET.CALL FOR UTILITY MARK-O)UT.MAINTAIN SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES SEPARATIONS TO SEPTIC COMPONENTS AND NOTIFY THE ENGINEER IF A 13.02 THE BASEMENT SHALL BE DRY BEFORE ANY INSULATION,FRAMING OR FINISH MATERIAL IS INS'TALLED.EXISTING WATER INTRUSION,EFFLORESCENCE,ACTIVE SEEPAGE,ELEVATED MOISTURE,MOLD WELL OR PIT FALLS WITHIN 10 FT OF A LEACHING POOL OR TANIK. GROWTH OR DRAINAGE DEFICIENCY SHALL BE IDENTIFIED AND CORRECTED BY THE OWNER BEFORE THE WORK PROCEEDS.NOTIFY THE ENGINEER WHERE SUCH A CONDITION IS ENCOUNTERED. F S 5.12 NO EXISTING BEAM,GIRDER,COLUMN,JOIST,BEARING WA1LL OR FOUNDATION ELEMENT SHALL BE CUT,NOTCHED,DRILLED,RELOCATED OR REMOVED WITHOUT THE ENGINEER'S PRIOR WRITTEN 13.03 WHERE ASBESTOS-CONTAINING MATERIAL,LEAD-BASED PAINT OR OTHER REGULATED MATERIAL IS ENCOUNTERED,STOP WORK IN THE AFFECTED AREA IMMEDIATELY.THE OWNER SHALL RETAIN A PROPOSED FINISHED AREA:TOTAL BASEMENT AREA: 1,551 51 SF APPROVAL. QUALIFIED LICENSED SPECIALIST.ABATEMENT IS OUTSIDE THIS SCOPE. MECHANICAL AREA: 531 SF 5.13 EXISTING SILL ANCHOR BOLTS WITHIN THE CUT SHALL BE]REMOVED.FASTEN THE SILL PLATE TO THE HEADER WITH 1/4"X 6"STRUCTURAL WOOD SCREWS AT 12"O.C.,STAGGERED.FASTEN EACH JACK 14.00 MEANS OF EGRESS TO THE CONCRETE JAMB WITH 114"CONCRETE SCREWS,2-1/2"MI]N.EMBEDMENT,AT 12"O.C.,AND THE PT SILL TO THE CONCRETE WITH THE SAME SCREWS AT 12"O.C.PROVIDE A SIMPSON A35 OR EQUAL AT 14.01 THE EXISTING BASEMENT STAIR TO THE GARAGE IS EXISTING TO REMAIN AND IS NOT ALTERED BY THIS WORK. ENGINEER OF RECORD:MEHMET F.AKDAG,P.E.,MFA ENGINEERING AND CONSULTING EACH HEADER-TO-JACK CONNECTION.PROVIDE AHELF-ADHERE3D FLEXIBLE FLASHING MEMBRANE OR FOAM SILL SEALER BETWEEN ALL WOOD AND CONCRETE SURFACES,INCLUDING UNDER THE SILL,AT THE JACK SIDES AGAINST THE CONCRETE JAMBS,AND AT THE MEADER ENDS.FASTENERS AND CONNECTORS IN CONTACT WITH PT LUMBER SHALL BE HOT-DIP GALVANIZED OR STAINLESS STEEL. 14.02 MAINTAIN THE MEANS OF EGRESS FROM THE BASEMENT THROUGH THE STAIR AND GARAGE,ANID THE PATH I TO THE EMERGENCY ESCAPE AND RESCUE OPENING,CLEAR AND UNOBSTRUCTED AT ALL OCTOBER 13,2026 TIMES,DURING AND AFTER CONSTRUCTION. 6.00 EMERGENCY ESCAPE AND RESCUE OPENING AND WINDOW WELLS AO COVER/GENERAL NOTES/SITE KEYPLAN 6.01 WI,THE NEW WINDOW IN THE RECREATIONAL AREA,IS THIE REQUIRED EMERGENCY ESCAPE AND RESCUE OPENING FOR THE BASEMENT AND COMPLIES WITH R319 AS SCHEDULED ON SHEET A2:NET 15.00 SURVEY,ZONING,FLOOD AND AGENCY DETERMINATIONS CLEAR OPENING 5.0 SF MINIMUM(BELOW-GRADE OPENING),NEV CLEAR WIDTH 20"MINIMUM,NET CLEAR HEIGHT 24"MINIMUM,SILL HEIGHT 44"MAXIMUM ABOVE THE FINISHED FLOOR;WELL AREA 9 SF 15.01 THE SITE KEY PLAN IS PREPARED FROM A SURVEY BY KENNETH M.WOYCHUK LAND SURVEYING;,PLLC,FILE NO.221-223,DATED DECEMBER 22,2021,FURNISHED BY THE OWNER.IT IS NOT A SURVEY AI EXISTING&PROPOSED BASEMENT PLANS MINIMUM WITH 36"MINIMUM PROJECTION AND WIDTH;PERMANTENT LADDER OR STEPS WHERE THE WELL IS DEEPER THAN 44". AND SHALL NOT BE USED AS ONE.THE ENGINEER IS NOT A LICENSED LAND SURVEYOR AND HAS PERFORMED NO SURVEY.STRUCTURES SHOWN ON THAT SURVEY AS PROPOSED MAY SINCE HAVE BEEN A2 EGRESS WINDOW DETAILS AND HEADER CHECK SUMMARY CONSTRUCTED.THE OWNER IS RESPONSIBLE FOR FURNISHING AN UPDATED SURVEY IF THE BUILDIN&DEPARTMENT REQUIRES ONE. A3 TYPICAL DETAILS 6.02 W2,THE ENLARGED HALLWAY WINDOW,IS PROVIDED FOR LIGHT AND VENTILATION ONLY.IT IS NOT AN EMERGENCY ESCAPE AND RESCUE OPENING AND R319 DOES NOT APPLY TO IT. 15.02 THE FOLLOWING WERE NOT PERFORMED BY THE ENGINEER UNDER THIS SCOPE AND ARE THE RESPONSIBILITY OF THE OWNER:FLOOD ZONE DETERMINATION,BOARD OF TRUSTEES WETLAND " 6.03 WINDOW UNITS AND WELLS ARE FURNISIED AND INSTALLED BY EGRESS PROS,THE OWNER'S EGRESS CONTRACTOR.W 1:EGRESS PROS TINT 5048,50"W x 48"H TWIN TILT-AND-TURN IN-SWING VINYL JURISDICTION DETERMINATION,LWRP CONSISTENCY REVIEW,ZONING ANALYSIS,MUNICIPAL RECORDS SEARCH AND OPEN PERMIT SEARCH. WINDOW,NET CLEAR OPENING 20-1/2"W x 42"11=6.0 SF PER SASH PER THE MANUFACTURER'S SPEC SHEET,CLEAR SILL APPROXIMATELY 40-1/4"ABOVE THE FINISHED FLOOR,WITH A 56"W x 36"PROJECTION x 72"H WELL.W2:EGRESS PROS TNT 4231,42"W x 31"H TILT-AND-TU1RN IN-SWING VINYL WINDOW,CLEAR OPENING 36"W x 25"H,WITH A 56"W x 36"PROJECTION x 6011 WELL.NO SUBSTITUTION FOR W 1 WITHOUT 15.03 WHERE THE WORK IS DETERMINED TO LIE WITHIN A SPECIAL FLOOD HAZARD AREA,WITHIN THE'JURISDICTION OF THE TOWN OF SOUTHOLD BOARD OF TRUSTEES,OR TO REQUIRE ZONING RELIEF, r THE ENGINEER'S REVIEW OF NET CLEAR OPENING DATA.WOOD MUCKS AND FURRING IN CONTACT WITH CONCRETE SHALL BE PRESERVATIVE-TREATED(ACQ OR EQUAL),WITH A MEMBRANE OR SILL SEALER ADDITIONAL APPROVALS AND ADDITIONAL DESIGN WILL BE REQUIRED AND ARE OUTSIDE THIS SCOPE. BETWEEN THE WOOD AND THE CONCRETE PER NOTE 5.13. 15.04 THE OWNER IS RESPONSIBLE FOR DISCLOSING ALL KNOWN UNPERMITTED WORK,PRIOR VIOLATIONS,OPEN OR EXPIRED PERMITS,RECORDED COVENANTS AND PENDING AGENCY MATTERS AFFECTING 6.04 W 1:EITHER SASH ALONE PROVIDES THE REQUIRED NET CLEEAR OPENING.THE 20-1/2"CLEAR WIDTH IS 1/2"OVER THE 20"MINIMUM;HANDLES,HINGES,SCREENS,STOPS AND INTERIOR TRIM SHALL NOT THE PROPERTY.THE ENGINEER IS NOT RESPONSIBLE FOR CONSEQUENCES ARISING FROM UNDISCLOSED CONDITIONS.RESOLUTION OF OPEN PERMITS OR LEGALIZATION OF EXISTING STRUCTURES,IF CLIENT: TAX MAP NO: REDUCE IT.SET THE UNITS TOWARD THE INTERIOR FACE OF THE;WALL SO EACH IN-SWING SASH OPENS A FULL 90 DEGREES INTO THE ROOM,CLEAR OF THE INTERIOR RETURNS,SOFFITS,HVAC REGISTERS REQUIRED BY THE TOWN,IS OUTSIDE THIS SCOPE. AND GRILLES AND FIXED FURNISHINGS.T1IE OPENING SHALL BE OPERABLE FROM THE INSIDE WITHOUT KEYS,TOOLS,SPECIAL KNOWLEDGE,OR FORCE GREATER THAN THAT REQUIRED FOR NORMAL 16.00 CONSTRUCTION AND INSPECTIONS HAKAN ERGULEC 1000-109.00-03.00-002.016 OPERATION,AND SHALL OPEN TO A YARD THAT LEADS TO A PUI13LIC WAY.TI IF WELL COVER,AND ANY GRATE,GRILLE OR SCREEN,SHALL RELEASE OR REMOVE FROM THE INSIDE UNDER THE SAME 16.01 THE ENGINEER'S SERVICES ARE LIMITED TO PREPARATION OF THESE CONSTRUCTION DOCUMENTS.CONSTRUCTION OBSERVATION,SITE VISITS,PROGRESS OR SPECIAL INSPECTIONS,TESTING,SHOP CONDITIONS. DRAWING REVIEW,CERTIFICATION OF COMPLETED WORK AND AS-BUILT DOCUMENTATION ARE NOT ENCLUDED UNLESS THE ENGINEER IS SEPARATELY RETAINED IN WRITING. 6.05 THERE IS NO EXISTING FOUNDATION DRAIN.DRAIN EACH WELL TO A 3/4"CLEAN STONE PIT UNDER THE FULL WELL FOOTPRINT PLUS 6",WITH FILTER FABRIC AT THE SIDES AND TOP AND A 4" PROJECT: PERFORATED PVC STANDPIPE WITH GRATE CAP.THE PIT BOTTOW SHALL REMAIN ABOVE THE BOTTOM OF THE FOOTING.LEVEL THE STONE NOT LESS THAN 4"BELOW THE WINDOW.SET THE TOP OF EACH WELL APPROXIMATELY 3"ABOVE FINISH GRADE AND ANCHOR PER THE MANUFACTURER.SLOPE FINISH GRADE AWAY NOT LESS THAN 1"PER FOOT. 16.02 THE ENGINEER HAS NO CONTROL OVER AND NO RESPONSIBILITY FOR CONSTRUCTION MEANS,MIETHODS,TECHNIQUES,SEQUENCES OR PROCEDURES,FOR SAFETY PRECAUTIONS OR PROGRAMS,OR FIM SHED BASEMENT & EGRESS WIN. FOR THE ACTS OR OMISSIONS OF ANY CONTRACTOR,SUBCONTRACTOR OR SUPPLIER. 6.06 FINISH GRADE AT THE WELLS IS ASSUMED AT APPROX}MATTELY 83"ABOVE THE SLAB AND SHALL BE VERIFIED AT EXCAVATION.WHERE GRADE IS HIGHER,EXTEND THE WELL.THE OPENINGS,HEADERS f N� PROJECT 16.03 THE CONTRACTOR IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL APPLICABLE SAFETY REQUIREMENTS,INCLUDING OSHA,AND FOR PROTECTION OF THE EXISTING STRUCTURE,ADJACENT Q AND WINDOWS ARE UNCHANGED. PROPERTY,OCCUPANTS AND THE PUBLIC THROUGHOUT CONSTRUCTION. 'P Farty "' yQ 1580 COUNTRY CLUB DR� 9 KEEP THE EGRESS PATH FROM THE W 1 WELI,TO THE YARD ��. 6.07 THE RECREATIONAL AREA IS AN OPEN AREA WITHOUT A MOOR,AND THE PATH FROM THE MAIN AREA TOW 1 IS OPEN AND UNOBSTRUCTED. G �(,. � CLEAR.LANDSCAPING,FENCING AND EQUIPMENT,INCLUDING TIRE HEAT PUMP OUTDOOR UNIT,SHALL NOT OBSTRUCT IT. 16.04 NO WORK SHALL BEGIN,INCLUDING CUTTING OF THE FOUNDATION WALL,UNTIL THE BUILDING,PERMIT HAS BEEN ISSUED.ALL INSPECTIONS REQUIRED BY THE AUTHORITY HAVING JURISDICTION CO �� * CUTCHOGUE, NY, 1193 5 SHALL BE SCHEDULED AND OBTAINED BY THE CONTRACTOR OR THE OWNER,INCLUDING AT MINIMUNA THE FOUNDATION OPENINGS,HEADERS AND WINDOW WELLS BEFORE BACKFILL;FRAMING AND * 6.08 FALL PROTECTION:BOTH WELLS EXCEED 30"IN DEPTH BEL60W ADJACENT GRADE.PROVIDE THE MANUFACTURER'S CLEAR POLYCARBONATE COVER ON EACH WELL,RATED FOR THE ANTICIPATED FIREBLOCKING WITH ROUGH ELECTRICAL AND MECHANICAL;INSULATION BEFORE IT IS COVERED;ELIF,CTRICAL FINAL BY THE APPROVED INSPECTION AGENCY;AND BUILDING FINAL.NO WORK SHALL BE r �0 CG PREPARED BY: LOAD.THE Wl COVER SHALL OPEN FROM WITHIN THE WELL WPITHOUT KEYS,TOOLS OR SPECIAL KNOWLEDGE. CONCEALED BEFORE THE REQUIRED INSPECTION IS COMPLETED AND APPROVED. n Ill MFA ENGINEERING& CONSULTING 16.05 THE CONTRACTOR SHALL HOLD A SUFFOLK COUNTY HOME IMPROVEMENT LICENSE AND SHALL,MAINTAIN NEW YORK STATE WORKERS COMPENSATION AND DISABILITY COVERAGE THROUGHOUT to 2 MEHMET F. AKDAG 7.00 FIRE PROTECTION,FIREBLOCKING AND FINISHES THE WORK. 2( VX - 7.01 INSTALL FIREBLOCKING PER R302.11,INCLUDING CONCEALIED STUD WALL SPACES AT CEILING AND FLOOR LEVELS AND AT 10-FOOT MAXIMUM HORIZONTAL INTERVALS,EVERY INTERCONNECTION 76 W 2ND STREET m BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES INCLUDING EACH SOFFIT-TO-WALL AND SOFFIT-TO-CEILING INTERSECTION,AND AT OPENINGS AROUND VENTS,PIPES,DUCTS,CABLES AND 109 jA0 17.00 CHANGES,SUBSTITUTIONS AND USE OF THESE DOCUMENTS A ''v DEER PARK,NY, 11729 `', ' WIRES.SEAL PENETRATIONS WITH AN APPROVED MATERIAL.SEIE DETAIL 7/A3. 17.01 NO CHANGE,DEVIATION,SUBSTITUTION OR VALUE-ENGINEERING PROPOSAL AFFECTING THE WORK SHOWN SHALL BE MADE WITHOUT THE ENGINEER'S PRIOR WRITTEN APPROVAL.UNAPPROVED ��FESS� �A MFA@MFAENGINEEWNG.COM ENGINEERING&CONSULTING 7.02 EXISTING FLOOR FRAMING IS 2x10 DIMENSIONAL LUMBER PER THE 1986 PLAN,FIELD VERIFY.MEMBRANE PROTECTION UNDER R302.13 IS PROVIDED BY THE GYPSUM BOARD CEILING THROUGHOUT THE CHANGES ARE MADE AT THE SOLE RISK OF THE PARTY MAKING THEM. 646-267-4827 FINISHED AREA AND THE 5/8"TYPE X CEILING IN THE MECHANICAL ROOM. 17.02 ROOM LAYOUT,ROOM USES AND THE WINDOW LOCATIONS ARE FIXED AS FILED.ANY CHANGE AFTER FILING REQUIRES AMENDED FILINGS. 7.03 INTERIOR WALL AND CEILING FINISHES SHALL HAVE A FLAME SPREAD INDEX NOT GREATER THAN 200 AND A SMOKE-DEVELOPED INDEX NOT GREATER THAN 450,PER R302.9.USE 1/2"GYPSUM BOARD, NO DESCRIPTION DATE WITH MOLD-RESISTANT BOARD ON THE LOWER PORTION OF THE FOUNDATION WALLS. 17.03 THESE DRAWINGS ARE INSTRUMENTS OF SERVICE AND REMAIN THE PROPERTY OF MFA ENGINEERING AND CONSULTING.THEY ARE PREPARED SOLELY FOR THIS PROJECT,AT THIS ADDRESS,FOR THIS DRAWING TITLE: . OWNER.REPRODUCTION,REUSE OR MODIFICATION FOR ANY OTHER PROJECT OR SITE WITHOUT WRITTTEN AUTHORIZATION IS PROHIBITED. MEHMET F. AKDAG, P.E. 7.04 EXPOSED INSULATION,FACINGS AND VAPOR RETARDERS SMALL COMPLY WITH R302.10.KRAFT-FACED BATT INSULATION SHALL NOT BE LEFT EXPOSED. 17.04 IT IS A VIOLATION OF NEW YORK STATE EDUCATION LAW SECTION 7209(2)FOR ANY PERSON,UNILESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THESE NYS LICENSE #109510 COVER PAGE 7.05 MECHANICAL ROOM:AS DIRECTED BY THE TOWN OF SOUTIHOLD FIRE MARSHAL,ENCLOSE THE MECHANICAL ROOM CONTAINING THE GAS-FIRED BOILER AND WATER HEATER WITH PARTITION TYPE P2: DRAWINGS IN ANY WAY.WHERE AN ITEM IS ALTERED,THE ALTERING ENGINEER SHALL AFFIX THEIR SEAL AND THE NOTATION"ALTERED BY,"FOLLOWED BY A SIGNATURE,THE DATE AND A SPECIFIC 5/8"TYPE X GYPSUM BOARD ON ALL WALLS AND THE CEILING OIN THE MECHANICAL ROOM SIDE,JOINTS TAPED,PENETRATIONS FIRESTOPPED WITH A LISTED SYSTEM.EACH DOOR TO THE MECHANICAL DESCRIPTION OF THE ALTERATION. ROOM(2)SHALL BE A 20-MINUTE FIRE-RATED DOOR ASSEMBLY]WITH LABELED DOOR AND FRAME,SELF-CLOSING AND POSITIVE-LATCHING,WITH NO LOUVERS OR TRANSFER GRILLES.SEE DETAIL 5/A3. DRAWN BY: CHECKED BY: SCALE: DATE: PROJECT NO: DRAWING NO: 17.05 ONLY DRAWINGS BEARING THE ORIGINAL SIGNATURE AND SEAL OF THE ENGINEER OF RECORD,ARE VALID FOR CONSTRUCTION OR FILING.ELECTRONIC FILES AND UNSEALED PRINTS ARE FOR AO 7.06 BASEMENT ENTRY DOOR AT THE STAIR TO THE GARAGE:TIRE EXISTING STEEL DOOR MAY REMAIN WHERE IT IS SOLID OR HONEYCOMB-CORE STEEL NOT LESS THAN 1-3/8"THICK,OR 20-MINUTE INFORMATION ONLY.IN THE EVENT OF A DISCREPANCY,THE SIGNED AND SEALED SET GOVERNS. FIRE-RATED,AND IS SELF-CLOSING AND SELF-LATCHING PER R302.5.1.VERIFY IN THE FIELD AND ADJUST OR REPLACE AS REQUIRED.MAINTAIN THE EXISTING GYPSUM SEPARATION BETWEEN THE GARAGE 17.06 THE ENGINEER'S SEAL APPLIES ONLY TO THE WORK SHOWN AND EXPRESSLY DESIGNED ON THESE DRAWINGS.IT DOES NOT EXTEND TO EXISTING CONSTRUCTION,TO WORK BY OTHERS,TO FA MFA N/A 10/13/26 1580 COUNTRY SHEET NO: AND THE DWELLING PER R302.6. ELECTRICAL,PLUMBING OR MECHANICAL DESIGN,OR TO ANY CONDITION NOT SHOWN. 1 OF 4 - - i WELL ELECT.PANEL /i�j 0 7 , 7'-1" >t C) 3.5" DIAMETER EXISTING o STEEL ZIP MECHANICAL/UTILITY COLUMN AREA 5'-11" TANK BOILER N M EXISTING CHIMNEY MASONRY 21-2° EXISTING o 0 28-2" o O GA GE STORAGE SPACE FO DATION AIR 20-8" HANDLER UNIT Al NOTES ELECT PANEL, 0 1. NEW EMERGENCY ESCAPE AND RESCUE OPENING WI WITH 56"W x 36" WELL. SEE 1, 1.1, 1.2/A2. 2. REPLACE AND ENLARGE EXISTING 30"x22"CELLAR WINDOW WITH 42"W x 31"H WINDOW W2,NEW HEAD 5-1/2"BELOW EXISTING HEAD, WITH 56"W x 36" WELL.NOT AN EGRESS WINDOW. SEE 2,2.1,2.2/A2. y 3. EACH DOOR TO THE MECHANICAL ROOM(2): 20-MINUTE FIRE-RATED DOOR ASSEMBLY,32"MIN., o z SELF-CLOSING,POSITIVE-LATCHING,NO LOUVERS. SEE NOTE 7.05. n 0 4. EXISTING STEEL DOOR AT STAIR TO GARAGE TO REMAIN, SELF-CLOSING AND SELF-LATCHING. SEE " .4 NOTE 7.06. = z ty 5. EXISTING GAS-FIRED BOILER AND WATER HEATER,VENTED TO EXISTING CHIMNEY.MAINTAIN 30"x FILTER 30"WORKING SPACE AND CLEARANCES. COMBUSTION AIR FROM OUTDOORS. SEE NOTES 11.02 AND 11.04. 3.5"DIAMETER 6. EXISTING AIR HANDLER(WITHIN THE MECHANICAL ROOM)AND FILTER TO REMAIN.MAINTAIN STEEL ZIP EXISTING SERVICE ACCESS. RETURN AIR FULLY DUCTED FROM OUTSIDE THE MECHANICAL ROOM;CABINET ' COLUMN ST.'AIRS TO GARAGE AND PLENUM SEALED. SEE NOTE 11.05. EXISTING WINDOW EXISTING WINDOW 7. NEW DUCTED HEAT PUMP FAN COIL(FC)IN THE MECHANICAL ROOM ADJACENT TO THE,EXISTING AIR 30"X27" 30"x22" HANDLER EQUIPMENT,WITH ONE SUPPLY REGISTER IN THE RECREATIONAL AREA AND ONE IN THE MAIN AREA AND A DUCTED RETURN FROM THE FINISHED AREA,BY THE OWNER'S HVAC CONTRACTOR. EXISTING BASEMENT PLAN RETURN DUCTED FROM OUTSIDE THE MECHANICAL ROOM;CABINET SEALED.DUCT ROUTING, REGISTER AND GRILLE LOCATIONS ARE DIAGRAMMATIC. SEE NOTES 11.05 AND 11.07 TO 11.12. 8. REFRIGERANT LINE SET TO OUTDOOR UNIT, SLEEVED AND SEALED ABOVE GRADE. 9. EXISTING 3-1/2"DIA. STEEL COLUMNS AND(3)2x10 GIRDER TO REMAIN.DO NOT ALTER. 10. SOFFIT AT EXISTING DUCTS AND PIPING, 80"MIN.ABOVE SLAB. SEE NOTE 4.02. 11. EXISTING FLOOR DRAIN AND WASTE LINE TO REMAIN.PROTECT;ACCESS PANEL AT CLEANOUT. 12. RIMIBAND JOIST: CUT-AND-FIT BATT INSULATION R-20 MIN.,AIR-SEALED,AROUND FULL PERIMETER. SEE 7/A3. 13. DIMENSIONS ARE TO FACE OF STUD OR FACE OF CONCRETE UNLESS NOTED.VERIFY ALL DIMENSIONS IN THE FIELD. ELECT.PANEL 14. FINISHED CEILING HEIGHT 88-1/2"ABOVE SLAB UNLESS NOTED(2x4 ON EDGE BELOW JOISTS+ 1/2"GYP. BD.). SOFFITS 80"MIN.ABOVE SLAB. 15. ALL NEW DOORS 32"MIN.CLEAR UNLESS NOTED. DASHED/GRAYED AREAS 16. NO SLEEPING ROOMS.RECREATIONAL AREA AND MAIN AREA ARE OPEN AREAS WITHOUT DOORS. _------ - ------ -------- -- DENOTES SOFFIT AREAS 17. NO PLUMBING FIXTURES ARE PROPOSED. 5/8"TYPE X,MECHANICAL ROOM SIDE 18. INSULATE THE FULL FOUNDATION PERIMETER INCLUDING THE MECHANICAL/UTILITY ROOM AND ELL W SEE 5/A3 ------- - ---------------- -- STORAGE AREAS.INTERIOR PARTITIONS DO NOT REQUIRE INSULATION. 24'-6" PROP. 19. ELECTRICAL LAYOUT IS BY THE OWNER'S LICENSED ELECTRICIAN UNDER A SEPARATE PERMIT. SEE o z 7'-1' MECHANICAL/ WALK IN 5'- o" _ SECTION 10.00. n CLOSET ]UTILITY ROOM N 20. SMOKE AND CO ALARMS: HARD-WIRED,INTERCONNECTED,BATTERY BACKUP,3 FT MIN.FROM IIVAC � ,_3.. SUPPLY REGISTERS AND RETURN GRILLES. SD/CO IN THE MAIN AREA,HALLWAY AND RECREATIONAL - z AREA. UPPER FLOORS PER NOTES 9.01 AND 9.02. d 0 0 20 IN FIRE -cNn RATED PROPOSED MAIN AREA AREA TABLE -- TOTAL BASEMENT AREA: 1,551 SF r 7'. 0^ FINISHED AREA (MAIN AREA,RECREATIONAL AREA,HALLWAY,WIC 1,WIC 2): -1,020 SF 92'-5" 3.5 DIAMETER STEEL ZIP 22 8„ SD/CO CAMECHANICAL/UTILITY AREA(UNFINISHED): -531 SF I COLUMN M EXISTING CHIMNEY PROPOSED BOXED 19'-10" --------- ---- --- - PROPOSED o FOUND ION -- ----- ------- GARAG MASONRY ❑o 0 RECREATIONAL AREA. ---- -- -- ------ I ( PROP. I 20 EXIST. WALK IN I 27'-2" AIR CLOSET 2 7'o" --------- -------- ----------------- HANDLER �ROP.AIR ( HANDLER ----- -------- ----------------- ELECT. PANEL I UNIT UNIT FOR 3 / I O HVAC 12' I / 2,-3„ I 32" 32" --------f 3'-3" SD/CO " " I I I I 4'-s" N 7" Ng I I ® M 1 CLIENT: TAX MAP NO: d j I I SD/CO 4-9" HAKAN ERGULEC � I FILTER 1000-109.00-03.00-002.016 ACCESS POINT FOR I r-4° $ WASTE LINE 1 1 R " " 77 _j PROJECT: ,,, . , , , , EXISTING FINISHED BASEMENT & EGRESS WIN. STAIRS TO GARAGE OF NEB r PROJECT EXISITIN�GX�INDOW (W2 Q�� i FAT/H 0 1580 COUNTRY CLUB DR (WI PROP.ENLARGEMENT LEGEND co a4l ��� p * CUTCHOGUE, NY, 11935 PROP.EGRESS WINDOW OF EXIST. WINDOW 42 X 31 PROPOSED BASEMENT PLAN 50"X 48" CENTERED CENTERED ON WALL DENOTES EXISTING F- G� CG PREPARED BY: ON WALL NOT AN EGRESS WINDOW* WALLS TO REMAIN fi ►� 2 MFA ENGINEERING& CONSULTING PROPOSED WELL PROP. WELL _ MEHMET F. AKDAG ,; 56„W x 36 D x 72 H 56 WIDE X 36 DEPTH X 60 HIGH DENOTES NEW � 76 W 2ND STREET tt, (SEE 1/A2) (SEE 2/A2) NON-BEARING PARTITION OQRO raSS�p O�P� DEER PARK, NY, 11729 F1fiSS1 MFA@MFAENGINEERING.COM ENGINEERING&CONSULTING E 646-267-4827 '^--� DENOTES SOFFIT AREA L--_J NO DESCRIPTION DATE DENOTES ELECTRIC PANEL MEAET F. AKDAG, P.E. DRAWING TITLE: I Il DENOTES SMOKE/CO DETECTOR NYS LICENSE #109510 EXISTING & PROPOSED SD/CO (HARD WIRED BY NYS CODE) DRAWN BY: CHECKED BY: SCALE: DATE: PROJECT NO: DRAWING NO: Al FA MFA 1/4" = 1.0' 10/13/26 1580 COUNTRY SHEET NO: 2 OF 4 A2 WINDOW SCHEDULE EXIST.WOOD-FRAMED WALL W/CEDAR EXIST.WOOD-FRAMED WALL W/CEDAR SIDING(NO BRICK VENEER) SIDING(NO BRICK VENEER) WI RECREATIONAL AREA -NEW EGRESS WINDOW(EERO) UNIT:EGRESS PROS TTNT 5048: 50"W x 48"H TWIN TILT-AND-TURN,IN-SWING.CLEAR 20-1/2"W x 42"H=6.0 SF PER SASH CUT: T-6" W x T-7-1/2"H,EL.2'-11-1/2"TO UNDERSIDE OF SILL PLATE(EL. T-7) EXIST.SILL PLATE.TOP OF WALL EL. EXIST.SILL PLATE.TOP OF WALL EL. HEADER: (3)2x6 PT SOUTHERN PINE NO. 1,TIGHT TO SILL PLATE, ON(1)2x6 PT JACK EACH SIDE ON A PT 2x8 SILL, MEMBRANE AT 91".FASTEN TO HEADER PER 3/A3 91".FASTEN TO HEADER PER 3/A3 ALL WOOD-TO-CONCRETE CONTACT. ROUGH OPENING T-3"W x 4'-0-1/2"H CLEAR POLYCARBONATE COVER,OPENS CLEAR POLYCARBONATE WELL: 56"W x 36" PROJ.x 6'-0"H TOP EL. 86" LADDER/STEPS CLEAR COVER(FALL PROTECTION) FIN.CLG.EL.8£B-1/2"(2x4 ON EDGE+12"GYP.) FROM INSIDE FIN.CLG.EL.88-1/2"(2x4 ON EDGq1/2"GYP.) > > >5'-0"WELL BY INSTALLER,TOP EL.86" STONE PIT: EL. 0"TO 2'-6". WELL DEPTH+/-4'-5" /LADDER RE D OVER 44"CUT TO UNDERSI©E OF SILL PLATE 6'-0"WELL BY INSTALLER,TOP EL.86" EXIST.WINDOW REMOVED.CUT T (3"ABOVE GRADE) l Q ) OVER OPENIING WIDTH ONLY (3"ABOVE GRADE) UNDERSIDE OF SILL PLATE.NEW FLASHING OVER HEAD,LAPPED UNDER R319-REQUIRED/PROVIDED PT 2x FILLER TO INTERIOR FACE FLASHING OVER HEAD,LAPPED UNDER HEAD 5-1/2"BELOW EXIST.HEAD F SIDINGMIRB,SEAL SIDINGNVRB,SEAL PT 2x FILLER TO INTERIOR FACE FINISH GRADE EL.+)-g3" NET CLEAR AREA: 5.0 SF MIN. (BELOW GRADE)/6.0 SF PER SASH(MFR) (3)2x6 PT NO.11 HEADER,TIGHT FINISH GRADE EL.+/-83"(ASSUMED, (3)2x6 PT NO.1 HEADER,TIGHT VERIFY). (ASSUMED, TO SILL PLANE,ON(1)2x6 PT N FY).SLOPE AWAY 1"/FT MIN.,s" NET CLEAR WIDTH:20"MIN./20-1/2" (MFR) JACK EACH SIDE ON THE PT SILL VERIFY).SLOPE AWAY 1"/FT MIN.,6" TO SILL PLATE,ON(1)2x6 PT TOPSOIL NET CLEAR HEIGHT:24"MIN./42" (MFR) (DASHED BEYOND).SEE 3/A3 TOPSOIL JACK EACH SIDE ON THE PT SILL N EGRESS PROS T-TNT 5048:50"W x (DASHED BEYOND).SEE 3/A3 I SILL HEIGHT A.F.F.:44" MAX./+/40-1/4" 48"H TWIN TIILT-AND-TURN,IN- a EGRESS PROS TNT 4231:42"W x in SWING.CLEAR 20-1/2"W x 42"H= 31"H TILT-AND-TURN,IN-SWING. DAMPPROOF WALL FACE WITHIN WELL 6.0 SF PER SASH WELL AREA: 9 SF MIN./ 14.0 SF j PERMANENT LADDER/STEPS:12"MIN. NOT AN EGRESS WINDOW WELL PROJECTION: 36" MIN./36"CLEAR(VERIFY) n WIDE,18"MAX.O.C.,6"MAX. I CLEAR SILL+/-57-1/4"A.F.F. w PROJECTION (NOT AN EGRESS OPENING) WIDTH:WELL "MIN. 56" DAMPPROOF WALL FACE WITHIN WELL PT 2x8 SILL,FULL WIDTH OF 36" C1 EAR CUT,ON MEMBRANE OVER 4"PERF.PVC STANDPIPE W/GRATE CAP W2 HALLWAY-ENLARGED EXISTING WINDOW(NOT AN EERO) CONCRETE.BOTTOM OF CUT EL. a .. 4'-4-1/2" =" UNIT:EGRESS PROS TNT 4231: 42"W x 31"H TILT-AND-TURN,IN-SWING.NOT AN EGRESS WINDOW CUT: Y-10" W x Y-2-1/2"H,EL.T-4-1/2" TO UNDERSIDE OF SILL PLATE(EL. T-7") CLEAR SILLL+/-40-1/4"A.F.F. HEADER: (3)2x6 PT SOUTHERN PINE NO. 1,TIGHT TO SILL PLATE, ON(1)2x6 PT JACK EACH SIDE ON A PT 2x8 SILL,MEMBRANE (44"MAX.) • AT ALL WOOD-TO-CONCRETE CONTACT.ROUGH OPENING Y-7" W x T-7-1/2"H PT 2x8 SILL,FULL WIDTH OF 36' CLEAR MIN.CUT,ON MAEMBRANE OVER WELL: 56"W x 36"PROJ.x 5'-0"H PER OWNER TOP EL. 86" CLEAR COVER ALL PROTECTION � CONCRETE.BOTTOM OF CUT EL. a 4' PERF.PVC STANDPIPE W/GRATE CAP = 3/4"CLEAN STONE PIT,WELL FOOTPRINT ' �` ) •2-11-1/2 2'xPS+2x4 @ 16"O.C.+1/2" , e' +6",EL.l'-2"TO 4'-0-1/2",FILTER GYP.BD.,PT BOTTOM PLATE.SEE STONE PIT: EL. 1'-2"TO 4'-0-1/2". WELL DEPTH+/-2'-10-1/2" • ;. FABRIC SIDES AND TOP.KEEP ABOVE 7/A3 BOTTOM OF FOOTING EXISTING 30"x22" WINDOW REMOVED.NEW HEAD(UNDERSIDE OF HEADER) G HEAD(E 5-1/2"BELOW EXISTING H XIST.HEAD •• BOTTOM OF WELL EL.2'-2",SET INTO ASSUMED AT TOP OF WALL EL. 91"-VERIFY). 2"XPS+2X41 @ 16"O.C.+1/2" ,: :. STONE GYP.BD.,PT BOTfTOM PLATE.SEE MFR CLEAR OPENING 36"W x 25"H=6.25 SF;CLEAR SILL+/-57-1/4"A.F.F. 7/A3 •i BOTTOM OF WELL EL.l'-2",SET INTO R319 DOES NOT APPLY. WI IS THE REQUIRED BASEMENT EERO. ° ' STONE 3/4"CLEAN STONE PIT,WELL FOOTPRINT •' +6",SAN TOP.K KEEPFILTE ABOVE • 2.1 HEADER CHECK SUMMARY TOP OF SLAB/FIN.FLOOR EL. ' •'�• SIDES AND TOP.KEEP ABOVE BOTTOM OF TOP OF SLAB FIN.FLOOR EL. •;' 0., i FOOTING 0„ a (3) 2x6 PRESSURE-TREATED SOUTHERN PINE NO. 1 HEADER,TIGHT TO THE SILL PLATE,ON (1)2x6 PT JACK EACH SIDE ON A PT 2x8 SILL.NDS 2018 ASD.NO CONCRETE OR ARCHING ASSUMED ABOVE THE HEADER. • ' • •: . - EXIST.P.C.FOOTING,VERIFY - EXIST.P.C.FOOTING,VERIFY LOADS TRIBUTARY TO FRONT WALL(ROOF RAFTERS 16 FT, ATTIC 7.5 FT, 2ND FLOOR 7 FT; 1ST FLOOR 7.6 FT(INCLUDED • i + . .• WHERE THE EXISM 4"BRICK SHELF OCCURS AT THE OPENING,CUT THROUGH THE FULL WALL THICKNESS;SET BUCK AND WELL TO SUIT. WHERE THE EXIST.4"BRICK SHELF OCCURS AT THE OPENING,CUT THROUGH THE FULL WALL THICKNESS;SET BUCK AND WELL TO SUIT. CONSERVATIVELY)): ROOF DL 12, SNOW/LR 20;ATTIC DL 10,LL 10;FLOOR DL 10;2ND FLOOR LL 30(SLEEPING); 1 ST FLOOR LL 40; FRAME WALL 10 PSF x 17 FT.D=583 PLF,L=589 PLF, S=320 PLF.NO BRICK VENEER. O SECTION AT W1 - RECREATIONAL AREA - NEW EGRESS WINDOW O SECTION AT W2 - HALLWAY - REPLACE: / ENLARGE EXISTING WINDOW D+L= 1,172 PLF(CD 1.0);D+0.75(L+S)= 1,265 PLF (CD 1.15). (3) 2x6: S=22.7 IN3,I=62.4 IN4,A=24.75 IN2. FB= 1,350 PSI,FV= 175 PSI,FC-PERP=565 PSI, E= 1,600,000 PSI.CR= 1.15 (3-PLY NAILED,NDS 4.3.9). W l: CUT 4'-6",CLEAR 4'-3", SPAN 4'-4".D+L:M=33.0 IN-K, fb= 1,455/ 1,552 PSI(0.94). fv= 118/ 175 PSI (0.68).HEADER ON JACK 2,740 LB, 406/565 PSI (0.72).JACK ON SILL 332/565 PSI (0.59).DEFL.L/558 TOTAL,L/l,I 11 LIVE. W2: CUT 3'-10", CLEAR 3'-7", SPAN 3'-8". D+L: M=23.6 IN-K, fb= 1,042/ 1,552 PSI (0.67). fv=95/ 175 PSI (0.54). HEADER ON JACK 2,319 LB, 344/565 PSI (0.61).JACK ON SILL 281 /565 PSI(0.50).DEFL.L/922 TOTAL,L/1,834 LIVE. GOVERNING RATIO 0.94 (WI HEADER BENDING).ADEQUATE. BASIS: 2025 RCNYS.PG=20 PSF. DRY SERVICE (MC 19%MAX.IN SERVICE);LUMBER KDAT,NOT INCISED,GRADE-STAMPED 56" WELL 56" WELL NO. 1.DEFLECTION LIMITS L/360 LIVE,L/240 TOTAL.HEADER SHALL BE SHIMMED TIGHT TO THE SILL PLATE; SHORE UNTIL 4"STANDPIPE 4"STANDPIPE HEADER,JACKS AND SILL ARE INSTALLED AND FASTENED. STONE PIT, WELL STONE PIT, WELL 2.2 EGRESS / WINDOW NOTES +6"(DOTTED) +6"(DOTTED) LADDER/STEPS 1. WI IS THE EMERGENCY ESCAPE AND RESCUE OPENING(EERO)FOR THE BASEMENT AND COMPLIES WITH R319 AS SCHEDULED. W2 REPLACES AND ENLARGES THE EXISTING HALLWAY CELLAR WINDOW FOR LIGHT AND VENTILATION ONLY; IT IS NOT AN EERO AND R319 co 2x6 PT JACK EACH co 2x6 PT JACK EACH DOES NOT APPLY TO IT. WELL AREA 14.0 SF(9 SF MIN.) '`' SIDE; (3)2x6 WELL AREA 14.0 SF SIDE; (3)2x6 2. WINDOW UNITS AND WELLS ARE FURNISHED AND INSTALLED BY EGRESS PROS (OWNER'S CONTRACTOR). W1:TINT 5048, 50"W x 48"H HEADER ABOVE HEADER ABOVE TWIN TILT-AND-TURN IN-SWING,NET CLEAR OPENING 20-1/2"W x 42"H=6.0 SF PER SASH PER MANUFACTURER'S SPEC SHEET.W2: TNT 4231, (DASHED). MAY BE (DASHED). MAY BE 42"W x 31"H TILT-AND-TURN IN-SWING.NO SUBSTITUTION FOR W1 WITHOUT THE ENGINEER'S REVIEW OF NET CLEAR OPENING DATA. SET FLUSH TO SET FLUSH TO 3. W1: EITHER SASH ALONE PROVIDES THE REQUIRED NET CLEAR OPENING.THE 20-1/2"CLEAR WIDTH IS 1/2"OVER THE 20"MINIMUM; EITHER FACE EITHER FACE HANDLES,HINGES, SCREENS, STOPS AND INTERIOR TRIM SHALL NOT REDUCE IT. SET EACH IN-SWING SASH TO OPEN A FULL 90 DEGREES \.4.HFe' a a• G ° e 4e ' e e° .4.4 . ee d e' n d ° 44 CLEAR OF THE INTERIOR RETURNS, SOFFITS,HVAC EQUIPMENT AND FIXED FURNISHINGS.THE WINDOW, WELL COVER AND SCREEN SHALL e e e ° e• OPERATE FROM THE INSIDE WITHOUT KEYS,TOOLS OR SPECIAL KNOWLEDGE. 4. HEADERS PER THE HEADER CHECK SUMMARY ON THIS SHEET: (3)2x6 PRESSURE-TREATED SOUTHERN PINE NO. 1 (GRADE-STAMPED), 4'-6' CUT 3'-10" CUT KDAT,NOT INCISED,AT EACH OPENING, SET TIGHT TO THE UNDERSIDE OF THE EXISTING SILL PLATE, ON(1)PT 2x6 JACK EACH SIDE BEARING ON A PT 2x8 SILL THAT RUNS THE FULL WIDTH OF THE CUT.THE HEADER SHALL BEAR ON THE FULL 4-1/2" WIDTH OF EACH JACK; e HEADER AND JACKS MAY BE SET FLUSH TO EITHER FACE OF THE WALL TO SUIT THE WINDOW INSTALLATION. PROVIDE A SELF-ADHERED 37" TO CUT (36" MIN.) MEMBRANE OR FOAM SILL SEALER BETWEEN ALL WOOD AND CONCRETE SURFACES.NAIL PLIES WITH 16d HOT-DIP GALVANIZED NAILS,2 a ROWS AT 12" O.C.EACH PLY, STAGGERED.NO.2 GRADE LUMBER SHALL NOT BE SUBSTITUTED. SEE DETAIL 3/A3. CENTERED ON EXISTING CELLAR WINDOW PER OWNER PLAN. FIELD VERIFY. 5. AN ALTERNATE HEADER PROPOSED BY THE EGRESS CONTRACTOR MAY BE SUBMITTED TO THE ENGINEER WITH SIZE, SPECIES, 5'-4" TO C.L. (VERIFY) NOT AN EGRESS WINDOW.WELL SIZE PER OWNER. GRADE,BEARING AND ANCHORAGE.NO ALTERNATE SHALL BE INSTALLED WITHOUT THE ENGINEER'S WRITTEN APPROVAL. e.a 6. SEQUENCE: EXCAVATE; SHORE FIRST-FLOOR FRAMING; WET SAW-CUT THE OPENING TO THE UNDERSIDE OF THE SILL PLATE, CENTERED ON FRONT WALL OF RECREATIONAL AREA PER OWNER PLAN. FIELD VERIFY. CORE-DRILL CORNERS,NO OVERCUT;APPLY MEMBRANE TO THE CONCRETE CONTACT SURFACES; SET THE PT SILL ON THE CONCRETE; SET WELL PLAN AT W2 JACKS ON THE SILL AND FASTEN TO THE CONCRETE JAMBS; SET THE HEADER AND SHIM TIGHT TO THE SILL PLATE; FASTEN SILL PLATE TO 2. HEADER AND HEADER TO JACKS;REMOVE SHORING;FLASH AND SET WINDOW;DAMPPROOF WALL FACE;FABRIC, STONE PIT, STANDPIPE; WELL PLAN AT W 1 SET AND ANCHOR WELL;BACKFILL,TOPSOIL, SLOPE GRADE; INSTALL COVER. 7. WALL ASSUMED 8" CAST-IN-PLACE CONCRETE AT THE OPENINGS, WITH AN EXISTING 4" EXTERIOR BRICK SHELF(NO BRICK) WHERE IT OCCURS.VERIFY THICKNESS, MATERIAL AND CONDITION BEFORE CUTTING.IF THE WALL IS MASONRY, STOP WORK AND NOTIFY THE ENGINEER. 8. VERIFY AT EXCAVATION: SILL ANCHOR BOLTS WITHIN THE CUT(REMOVE AND REPLACE BY THE SILL-TO-HEADER SCREWS IN DETAIL 3/A3);FIRST-FLOOR WINDOW JAMBS ABOVE EACH OPENING(NOTIFY THE ENGINEER IF A JAMB FALLS WITHIN A HEADER SPAN); EXISTING W2 HEAD ELEVATION; FINISH GRADE. 9. W2: REMOVE THE EXISTING 30"x22"WINDOW.CUT THE ENLARGED OPENING TO THE UNDERSIDE OF THE SILL PLATE.THE NEW HEAD (UNDERSIDE OF HEADER) IS 5-1/2" BELOW THE EXISTING HEAD. GRADE+/-83"(ASSUMED) GRADE+/-83"(ASSUMED) EXIST. 30"x22" 10. KEEP EACH CUT 36"MIN.FROM A FOUNDATION CORNER.MAINTAIN SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES (:3)2x6 PT NO. 1 (3)2x6 PT NO. 1 WINDOW TO BE SEPARATIONS TO SEPTIC COMPONENTS;NOTIFY THE ENGINEER IF A WELL OR PIT FALLS WITHIN 10 FT OF A LEACHING POOL OR TANK. HEADER TIGHT TO HEADER TIGHT TO I _04 REMOVED(DASHED) 11. WI WELL: 56"W x 36"CLEAR PROJECTION MIN.(VERIFY INSIDE DIMENSION), 14.0 SF.PERMANENT LADDER OR STEPS REQUIRED(DEPTH SILL PLATE I I SILL PLATE EXCEEDS 44"): 12"MIN. WIDTH, 18"MAX.O.C., 6"MAX.PROJECTION,USABLE WITH THE WINDOW FULLY OPEN. W2 WELL: SIZE PER OWNER; LADDER NOT REQUIRED. 4 I 12. FALL PROTECTION: BOTH WELLS EXCEED 30"IN DEPTH BELOW ADJACENT GRADE.PROVIDE A MANUFACTURER'S CLEAR POLYCARBONATE COVER ON EACH WELL, RATED FOR THE ANTICIPATED LOAD.THE W1 COVER SHALL OPEN FROM WITHIN THE WELL (11)2x6 PT JACK r (1)2x6 PT JACK WITHOUT KEYS, TOOLS OR SPECIAL KNOWLEDGE. EACH SIDE ON PT EACH SIDE ON PT 13. NO FOUNDATION DRAIN EXISTS.DRAIN EACH WELL TO A 3/4"CLEAN STONE PIT, WELL FOOTPRINT PLUS 6", WITH FILTER FABRIC SILL, (FASTENED TO EGRESS PROS TINT SILL, FASTENED TO JAMB I EGRESS PROS TNT SIDES AND TOP AND A 4"PERFORATED PVC STANDPIPE WITH GRATE CAP.LEVEL STONE 4" MIN. BELOW THE WINDOW.KEEP PIT BOTTOM CONCRETE JAMB I I TWIN SO"W x 48"H CONCRETE JAMB TILT- ND- x N,I ABOVE THE BOTTOM OF THE FOOTING.TOP OF WELL 3"ABOVE GRADE; SLOPE GRADE AWAY 1"PER FOOT MIN.IF GRADE IS HIGHER THAN TWIN TILT-AND- 3'-10" CUT TILT-AND-TURN, IN- TURN, IN-SWING. SWING. NOT AN ASSUMED,EXTEND THE WELL; OPENING AND HEADER ARE UNCHANGED. CLEAR 20-1/2"W x I 3'-7" CLEAR BETWEEN ,JACKS I EGRESS WINDOW 14. NO FOUNDATION CUTTING BEFORE THE BUILDING PERMIT IS ISSUED. OPENINGS,HEADERS AND WELLS SHALL BE INSPECTED PT:2x8 SILL, FULL 42"H =6.0 SF PER PT 2x8 SILL, FULL 7 BEFORE BACKFILL. WIDTH OF CUT -- SASH WIDTH OF CUT 4'-6" CUT I I CLIENT: TAX MAP NO: MEMBRANE BETWEEN WET SAW-CUT, CORE- MEMBRANE BETWEEN WET SAW-CUT, CORE- WOOD ANID CONCRETE, 4'-3" CLEAR BETWEEN JACKS DRILL CORNERS, NO WOOD AND CONCRETE, DRILL CORNERS, NO HAKAN ERGULEC 1000-109.00-03.00-002.016 TYR I I OVERCUT TYR 56" WELL OVERCUT WELL BEYOND WELL BEYOND PROJECT: (DASHED) (DASHED) FINISHED BASEMENT & EGRESS WIN. 56" WELL I, PROJECT NEtV r0 1580 COUNTRY CLUB DR �,� F ATi/y ,� a, �� CUTCHOGUE, NY, 11935 t, qG3 CG PREPARED BY: I w MFA ENGINEERING & CONSULTING R` MEHMET F. AKDAG BACKFILL AND WELL REMOVED FOR CLARITY BACKFILL AND WELL REMOVED ROR CLARITY 2�� 76 W 2ND STREET g dA 095'I P�, DEER PARK,NY, 11729 pQ�Ess% MFA@MFAENGINEEMNG.COM ENGINEERING&CONSULTING 12 EXTERIOR ELEVATION AT W1 2 2 EXTERIOR ELEVATION AT W2 646-267-4827 NO DESCRIPTION DATE MERMET F. AKDAG, P.E. DRAWING TITLE: NYS LICENSE #109510 EGRESS WINDOW DETAILS AND HEADER CHECK SUMMARY DRAWN BY: CHECKED BY: SCALE: DATE: PROJECT NO: DRAWING NO: A2 FA MFA N/A 10/13/26 1580 COUNTRY SHEET NO: 3 OF 4 3 PLIES = 4-1 2• EXIST. WOOD-FRAMED WALL W/ A3 HVAC NOTES CEDAR SIDING (NO BRICK EXIST.SILL PLATE.SHIM VENEER)HEADER TIGHT(PT SHIMS OR 1. HEATING AND COOLING OF THE FINISHED AREA BY A DUCTED HEAT PUMP SYSTEM BY THE OWNER'S LICENSED HVAC PT 2x FILLER SILL NON-SHRINK ER:1/4) FASTEN x6' RIM/BAND JOIST: CUT-AND-FIT CONTRACTOR, INCLUDED UNDER THIS BUILDING PERMIT: OUTDOOR HEAT PUMP, DUCTED FAN COIL IN THE MECHANICAL TO INTERIOR STRUCTURAL SCREWS @ 12°FACE O.C.,STAGGERED BATT INSULATION R-20 MIN., ROOM ADJACENT TO THE EXISTING AIR HANDLER, ONE SUPPLY REGISTER IN THE RECREATIONAL AREA AND ONE IN THE AIR-SEALED AT PERIMETER MAIN AREA, DUCTED RETURN FROM THE FINISHED AREA. NO WALL-MOUNTED INDOOR UNITS.NOT DESIGNED BY THE (8.03) ENGINEER. SEE GENERAL NOTES 11.05 AND 11.07 TO 11.12. ° EXIST. SILL PLATE AND ANCHOR 2. CONTRACTOR IS RESPONSIBLE FOR EQUIPMENT SELECTION AND SIZING (ACCA MANUAL J AND S), DUCT DESIGN BOLTS (MANUAL D), REGISTER AND GRILLE LOCATIONS, REFRIGERANT PIPING, CONDENSATE DISPOSAL AND A2L REFRIGERANT e. 2x FIREBLOCKING AT TOP OF REQUIREMENTS. INSTALL PER MANUFACTURER. FURRED WALL (R302.11) 3. OUTDOOR UNIT ON PRE-CAST PAD WITH MANUFACTURER'S CLEARANCES AT THE LOCATION ON THE SITE KEY PLAN (3)2x6 PT SOUTHERN PINE ° - - - GRADE, SLOPE AWAY ' No 1,KDAT,NOT INCISED. A. OF THE WINDOW WELLS AND THE EGRESS PATH. DUCTS, REGISTERS AND GRILLES SHALL NOT OBSTRUCT THE W 1 16d HDG NAILS,2 Rows @ OWNER-ELECTED (I I-II II-IIII-III-I I WINDOW SWING. i 12"O.C.EACH PLY, c 1 III-III-III-III 9 I(� Lo STAGGERED.BEARS ON FULL R-30/R-38 KRAFT- °.' 4-1/2"OF EACH JACK III=1 I�1 I H 11=1 i 1� FACED BATTS CLG.: 2x4 ON EDGE a: BETWEEN JOISTS BELOW JOISTS + II-III=III=II�III=II�II� MECHANICAL ROOM FIRE SEPARATION NOTES :: III=III=ITi-i I I-►I I-1 I�I 3.1 (8.04) - NOT REQ'D 1/2"GYP. BD., I I-1 I M I I=i I I=III=1 I�I FLASHING OVER HEAD,LAPPED FIN. C sG. E2. .� `: I�I I I-I I I-I I I�11=1I�1 ., 11= I d 11=III=III I I-I I (=1 I V=l I 1=1 I 1=1 I 1=1 I 1. MECHANICAL ROOM (GAS BOILER GAS WATER HEATER EXISTING AIR HANDLER AND NEW HEAT PUMP FAN UNDER SIDING/WRB a' , -I I M �I I m I I 11=I I k EXIST. 8" P.C. FOUNDATION I 1=1 I i=1I ice--III- I h=I I COIL): ENCLOSE WITH PARTITION TYPE P2 (5/A3). 5/8" TYPE X GYPSUM BOARD ON ALL WALLS AND THE CEILING ON ° °.•• _�T1=1 i I-1 i I I I��� THE MECHANICAL ROOM SIDE, AS DIRECTED BY THE TOWN OF SOUTHOLD FIRE MARSHAL. WALL (4" BRICK SHELF WHERE I ml 11=1 I I-_ 11 I WINDOW HEAD OCCURS, NO BRICK) °' I�I I I=1 I�i I H I I�ICI-- i 2. EACH DOOR TO THE MECHANICAL ROOM(2): 20-MINUTE FIRE-RATED DOOR ASSEMBLY WITH LABELED DOOR II=I 11=1 I I-III=1 I I-I I�I AND FRAME SELF-CLOSING AND POSITIVE-LATCHING 32" MIN. AND SIZED TO REMOVE THE LARGEST APPLIANCE. =111=1 I I 11=1 I NO LOUVERS OR TRANSFER GRILLES. (1)2x6 PT JACK BEYOND, 3. COMBUSTION AIR: BECAUSE THE ENCLOSURE IS RATED, PROVIDE COMBUSTION AND VENTILATION AIR 5-1/2"DEEP,ON PT 2x8 2x4 WOOD STUDS @ `� (- H- - FROM OUTDOORS PER RCNYS CHAPTER 17 / G2407 SIZED BY THE MECHANICAL CONTRACTOR ON THE TOTAL INPUT SILL.1/4"CONCRETE SCREWS c. f=I (=1 I�I I I� I @ 12"O.C.TO JAMB ON 16" O.C. OF ALL GAS APPLIANCES IN THE ROOM. NO OPENINGS FROM THE FINISHED AREA INTO THE MECHANICAL ROOM. MEMBRANE;SIMPSON A35 1 11=11�1 I I HEADER-TO-JACK EACH SIDE e a =1 I I 4. NO RETURN AIR FROM THE MECHANICAL ROOM. RETURNS OF THE EXISTING AIR HANDLER AND THE NEW s" WALL VERIFY HEAT PUMP FAN COIL SHALL BE FULLY DUCTED FROM OUTSIDE THE MECHANICAL ROOM, WITH CABINETS, 2"XPS/EPS RIGID FOAM (R-10 HEADER AND JACKS MAY BE SET FLUSH TO EITHER FACE OF THE WALL TO SUIT THE WINDOW.PT 2x8 SILL,FULL WIDTH OF CUT,ON MEMBRANE,1/4"CONCRETE SCREWS @ 12"O.C. ° PLENUMS AND DUCT JOINTS IN THE ROOM SEALED. WHERE DUCTS OR REFRIGERANT PIPING PENETRATE P2 WALLS CI) OR R-13 CAVITY MIN. I=1I I=I I-I-I I(=1 =1 OR CEILING, USE STEEL DUCT AND A LISTED FIRESTOP SYSTEM; FIRE DAMPERS WHERE REQUIRED BY THE CODE SELF-ADHERED MEMBRANE OR FOAM SILL SEALER BETWEEN ALIL WOOD AND CONCRETE(UNDER SILL,JACK SIDES AT JAMBS,HEADER ENDS).FASTENERS HDG OR STAINLESS.SHORE UNTIL HEADER IS SHIMMED TIGHT AND FASTENED. (8.02) ° OFFICIAL. SEAL ALL OTHER PENETRATIONS OF P2 WALLS AND CEILING WITH A LISTED FIRESTOP SYSTEM. a I H 11=1 I I III=)I I I 5. CLOSETS: PARTITION TYPE P1 4/A3 MAINTAIN 30" x 30" WORKING SPACE AND SERVICE ACCESS AT THE ( )• C3) WOOD HEADER SECTION (TYPICAL AT W1 AND W2) III-III I I-I I�I H I� BOILER, WATER HEATER AND AIR HANDLER. a 4: m 1El 1=I I HTI-T�1 6. BASEMENT ENTRY DOOR AT STAIR TO GARAGE: EXISTING STEEL DOOR TO REMAIN IF 1-3/8" SOLID OR I I-I 11=1 I I=I a ° I I I�I MI I I - I HONEYCOMB-CORE STEEL, OR 20-MINUTE RATED, AND SELF-CLOSING AND SELF-LATCHING PER R302.5.1. VERIFY IN FIELD; ADJUST OR REPLACE AS REQUIRED. 1/2"GYP.BD-EACH SIDE 2x4 WOOD STUDS @ 16"O.C. I I I=1 11=1 I I-1 I H 1/2" GYP. BD., MOLD-RESISTANT AT 4' ° I I Ed MI I MI I I=1 11=I 1�1 LOWER WALL II-III-III=III- II_ It=1I WALL, INSULATION AND FIREBLOCKING NOTES a_. •. III-1 I I-III-III=III-I I�I 3.2 ° II I-j�7-j�1-I 11-1 I�-�j i I LBATT INSULATION(OPTIONAL(SOUND ONLY-NOT REQ'D,8.04 18 06) - '''-I I I�IT�-� ° . I I ICI 1. INSULATE THE FULL FOUNDATION PERIMETER, INCLUDING THE MECHANICAL/UTILITY ROOM AND OPARTITION TYPE P1 -TYPICAL STORAGE AREAS, PER DETAIL 7. INTERIOR PARTITIONS DO NOT REQUIRE INSULATION; BATTS IN P1 ARE • °e. A I I I �I� OPTIONAL FOR SOUND. 2. FIREBLOCK PER R302.11 AT CEILING AND FLOOR LEVELS OF FURRED WALLS, AT 10 FT MAX. HORIZONTAL �11H 11=1 I I=11�1 - 1 INTERVALS, AT SOFFIT-TO-WALL AND SOFFIT-TO-CEILING INTERSECTIONS, AND AT PENETRATIONS. a ... I IM I(=11 3. NO POLYETHYLENE VAPOR RETARDER ON BELOW-GRADE WALLS. KRAFT FACING SHALL NOT BE LEFT ° I I1=II�III-III�I=11I�I�II�I=II�I EXPOSED. FOAM PLASTIC COVERED BY 1/2" GYPSUM BOARD. Em ir='TYPE X GYP.BD,MECHANICAL ROOM SIDE 2x4 NgOD STUDS(Q 16"O.C. •. e. ' 1=1 I I-III-I I I�I H I�I 4. HEADER DETAIL 3 APPLIES TO W 1 AND W2. SEE SHEET A2 FOR THE WINDOW SCHEDULE AND HEADER -44 CHECK SUMMARY. EXIST. 4"SLAB, 11=III-I I I=1 I IEfl FIN. FLOG A ° .° 1�I I ICI I�I I�1 I I=I I I: PT- PT 2x4 BOTTOM PLATE, SILL _ - . GASKET 1 11=i I H I I=1 I I=1TI=11 _ 12"GYP.BD.,FINISHED SIDE a• •. . a• 4. ° RUN TYPE X TO UNDERSIDE OF 5f6'TYPE X MECH ROOM CEILING FIRESTOP ALL PENETRATIONS.TAPE ALL JOINTS •e .e •a 1=1 I�I I I-1 I I-III=1 I_H ' e .° '• a �. '.a ° ° 5 PARTITION TYPE ROOM ENCLOSURE Q : �1I�11I-III=III= 3_3 SMOKE / CO ALARM NOTES O ° - EXIST. P.C. FOOTING I=II1� I I�I III e ° III-III-I 1III- -1 I -'l 1. BASEMENT: HARD-WIRED, INTERCONNECTED, WITH BATTERY BACKUP, MOUNTED PER DETAIL 6. (A) COMBINATION I-III-III-III-III- SMOKE/CO ALARM ON THE MAIN AREA CEILING AT THE FOOT OF THE STAIR. (B) COMBINATION SMOKE/CO ALARM ON THE NO POLY VAPOR RETARDER ON BELOW-GRADE WALLS. BASEMENT MUST BE DRY BEFORE INSULATION (13.02). HALLWAY CEILING OUTSIDE THE MECHANICAL ROOM DOOR. (C) COMBINATION SMOKE/CO ALARM ON THE RECREATIONAL AREA CEILING. 2. KEEP ALARMS 3 FT MIN. FROM HVAC SUPPLY REGISTERS AND RETURN GRILLES, 4" MIN. FROM WALLS, AND OUT OF 7 TYPICAL BASEMENT EXTERIOR WALIL (WALL TYPE W1 ) THE MECHANICAL ROOM. 3. UPPER FLOORS: NO WORK SHOWN. OWNER TO VERIFY SMOKE ALARMS IN EACH BEDROOM, OUTSIDE EACH DEAD-AIR ZONE 4.,,,N SLEEPING AREA AND ON EACH STORY, AND CO ALARMS OUTSIDE EACH SLEEPING AREA AND ON EACH STORY (R310 / R311). SEE GENERAL NOTES 9.01 TO 9.03. zr CEILING-MOUNTED ALARM, 4"MIN. FROM WALL CLIENT: TAX MAP NO: (PREFERRED) HAKAN ERGULEC 1000-109.00-03.00-002.016 PROJECT: OR\WALL-MOUNTED,TOP OF FMSFIED BASEMENT & EGRESS WIN. ALAIRM CEILING 4"-12"BELOW 0f'<ti A�W PROJECT k{) 1580 COUNTRY CLUB DR co � ��a9* CUTCHOGUE, NY, 1193 5 HARD-\WIRED,INTERCONNECTED, BATTERY BACKUP.NOT INSIDE THE MECHANICAL ROOM. r � q(►'� a: PREPARED BY: MFA ENGINEERING& CONSULTING y $ MEHMET F. AKDAG C 6 SMOKE / CO ALARM MOUNTING A ross1 .�" 76 W 2ND STREET AAQFESS�O�Py MFA@MFAE GINEEMNG.COM ENGINEERING&CONSULTING 646-267-4827 NO DESCRIPTION DATE MEHMET F. AKDAG, P.E. DRAWING TITLE: NYS LICENSE #109510 TYPICAL DETAILS DRAWN BY: CHECKED BY: SCALE: DATE: PROJECT NO: DRAWING NO: A3 FA MFA N/A 10/13/26 1580 COUNTRY SHEETNO: 40F4