Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
51407-Z
TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51407 Date: 11/21/2024 Permission is hereby granted to: Joseph Alonzo 101 Warren St#3A Brooklyn, NY 11201 To: construct single-family dwelling as applied for per SCHD approval. All construction activity must remain 10' outside of 100'wetland boundary setback. Premises Located at: 2050 New Suffolk Rd, Cutchogue, NY 11935 SCTMI# 109.-5-19 Pursuant to application dated 07/30/2024 and approved by the Building Inspector. To expire on 11/21/2026. Contractors: Required Inspections: DRAINAGE, FOOTING/REBAR, FOUNDATION 1ST, FOUNDATION 2ND, FRAMING/STRAPPING , PLUMBING , ELECTRICAL- ROUGH, FIRE RESISTANT PENETRATION , ELECTRICAL- FINAL, INSULATION , FIRE SAFETY INSPECTION , FIRE RESISTANT CONSTRUCTION , FINAL, Fees: Single Family Dwelling-NEW $4,805.25 CO Single Family Dwelling-New $100.00 /I L Total $4,905.25 Building Inspector ^� . 7 TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. 0. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 h=s://www.southoldtommay.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. Building Inspector; Applications and forms must be filled out In their entirety.Incomplete .—Building Department applications will not be accepted. Where the Applicant is not the owner,an own of Soar► ! Owner's Authorization form(Page 2)shall be completed. Date: �la 0WNER(S),OF PROPERTY: Name:JOE AND JULIA ALONZO SCTM#1000-109-5-19 Project Address:2050 NEW SUFFOLK/ 600 CEDARS RD. Phone#:(917) 558-1484 Email:JALONZ0240@GMAIL.COM Mailing Address: 101 WARREN STREET, APT.#A3C, BROOKLYN, N.Y. 11201 CONTACT PERSON: Name:MICHAEL MUNOZ Mailing Address: 160 MCNAIR STREET, BRENTWOOD, N.Y. 11717 Phone#:631-464-6668 Email:MMUNOZ@CREATEDESIGNBUILDGROUP.COM DESIGN PROFESSIONAL INFORMATION: Name:DAVID CHAGNON Mailing Address: 1736 SHORE PARKWAY, BROOKLYN, N.Y. 11214 Phone#:646-764-3376 Email:dchagnon@dcarch-ny.com CONTRACTOR INFORMATION: Name:MARRCON DEVELOPMENT CORP., DANIEL MARRA Mailing Address: 137 GLENWOOD ROAD, GLENWOOD LANDING, NEW YORK 11547 Phone#:646-343-7400 Email:MARCONLLC@GMAIL.COM -DESCRIPTION,OF PROPOSED-CONSTRUCTION ENew Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other 1.5 M Will the lot be re-graded? ❑Yes I]No Will excess fill be removed from premises? ❑Yes 2No 1 PROPERTY INFORMATION Existing use of property:VACANT LAND Intended use of property:RESIDENTIAL SINGLE FAMILY Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R_40 this property? ❑Yes 2No IF YES,PROVIDE A COPY. 91 Check Box After Reading: The owner/contractor/deslgn professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town°Code. APPUC14'ON,IS HEREBY MADE to,tha Building Department for the Issuance of a Building Permit pursuant to the Building Zone Ordinance of the frown of Southold,Suffolk,Cou'raty,New"fork and tither applicable taws,Ordinances or iteguletlons,for the construction of buildings, additions,alterations or•for removal or demolition as hereein described.The applicant agrees to Damply with alai applicable laws,ordinances,building code, housing coda and regulations and to admit authorized Inspectors on premises and In bulldinglsl-for necessary Inspections,.False statements made herein are punishable as a Class ask misdemeanor pursuantto Secttion 22IM45,of the New York State,Penal Law, Application Submitted By(,p t name):M I C HAE L M U N OZ MAuthorized Agent Downer Signature of Applicant: Date: . os 01 STATE OF NEW YORK) _....,_.. SS: COUNTY OF SUFFOLK M I CHAE L M U N OZ being duly sworn,deposes and says that (s)he is the applicant (Name of individual signing contract)above named, (S)he isthe AGENT (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this da,y of 20 2L L/j&& XIJ-L, Notary Public Galaxina Munoz NOTARY PUBLIC,STATE OF NEW YORK PROPERTY OWNER AUTHORIZATION Registration No.0 1 MU0022236 Qualified in Suffolk County (Where the applicant is not the owner) Commission Eapires03/1312029 JOE ALONZO residing at 101 WARREN STREET, APT.#A3C, I, BROOKLYN, N.Y. 11201 MICHAEL MUNOZ do hereby authorize -to apply on my bpalfto7theTojoy�'� ut Building Department for approval as described herein. 2j- ner's rtgna Ure Date J6EE ALONZO Print Owner's Name 2 PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ❑No IF YES, PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional Is responsible for all drainage and storm water Issues as provided by Chapter 236 of the Town Code.APPLICATION IS HEREBY MADE to the Building Department for the Issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized Inspectors an premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 21D.4S of the New York State Penal Law. Application Submitted By(print name)•. y 'PO(-f'(U Q 2Authorized Agent ❑Owner Signature of Applicant: - '� g Pp Date: /)-012_gl2 -7 STATE OF NEW YORK) COUNTY OF A ) �o(4,b being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing ontract)above named, (S)he is the (Contractor,Agent, Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 2 LJ -1 day of �Ci �� 20 2 1 ,O/MW Public =Suffolk UFENANGER PROPERTY OWNER AUTHORIZATION STATE OF NEW YO K (Where the applicant is not the owner) o. 01A00019644. Suffolk Countyires January 9,,Z0 8 I, residing at Z 6 do hereby authorize AMP Architecture to apply on my behalf to the Town of Southold Building Department for approval as described herein. wner's Signature Mate Print Owner's Name 2 Scott A. Russell ST(01K1�\\1WAr]F1E]K SUPERVISOR Y N\4[A\N A\G]ENM[]EN]F SOUTHOLD TOWN HALL-P.O.Box 1179 p °, t � 53095 Main Road-SOUTHOLD,NEWYORK 11971 "' Town of Southold CHAPTER 236 - STORMWATER MANAGEMENT REVERRAL FORM W ( APPLICANT INFORMATION TO BE COMPLETED BY THE APPLICANT ONLY FOR PROPERTIES ONE ACRE IN AREA OR LARGER. ) APPLICANT: (Property Owner, Design Professional, Agent, Contractor, Other) NAME: Anthony Portillo Date: `p„01 10/10/24 -; i$iynalw el Contact Inf ormat loll. aportillo@amparchitect.com; (631) 603 - 9092 8 1 elephmie�'umhe, Property Address / Location of Construction Site: 2050 New Suffolk Road,Cutchogue,NY 11935 S.C.T.-M. #: 1000 �Di;tr,ci 109 5 19 Section Block Lot TO BE COMPLETED BY SOUTHOLD TOWN ENGINEERING DEPARTMENT " Area of Disturbance :s less than i Acre No S.P.D.E.S. PeMa t is Rec tada'ed Project does Not Discharge to Waters of the State No S-P.�-E.S. Permit is Re aired ! - .Area of Disturbance is Greater than I Acre & Storm-eater Runoff Discharges Directly to Waters of the State of New York. THE APPLICANT MUST OBTAIN a &P.D.E.S. Permit DIRECTLY From N.Y.S. D,E,C. Prior to Issuance of a Building Permit. [] Area of Disturbance is Greater than I Acre & Storm-v\ater Runoff Flours Through Southold Town's MS4 Systems to Waters of the State of Nevv York. THE APPLICANT MUST OBTAIN a S.P.D.E.S Permit through the Southold Town Engrineevina Department Prior to Issuance of a Bim1din, Permit. Rel ie%�ed B, Date- 0 3 FnRrvi � � CcI' v--e Id for two minutes. must be watertight and located outside the I%A OWT5 tank c tln Seal tank;fill tank with water to outlet invert 2. Any bl located outside of the l/A OATS unit must be t sla blowers located for 24 hours. Refill the tank to the outlet Invert on a pad (concrete, plastic or fiberglass) and have a sound our period 1'5 complete.. Let the tank stand for an enclosure cover. -hour period. The tank Is approved if water level Is 10-hour period. i+°laater ressure tasting Is 3. All pumps and floot trees must be accessible and service sd to be done onsite offer l tollation. from access openings. ink manufacturers shall provide a lobei of non-corrosive 4. The floats shall be attached to a Schedule 40 Pe/G float a prominent iocation at each access opening to warn that can be easily removed for service or adjustment. The f e into tank may be fatal'. shall not be attached to the force main. thYK O l i Ti hNA ITS= 5 The Department shall observe the pump system operate i to prefabricated septic tanks shall conform to the a normal operating cycle. Association of Plumbing and Mechanical Officials b.lnspection for leakage of the force main fittings will be me rmerican rational Standard for Prefabricated Septic during the pump test procedure. Z1000-200"! and any applicable revisions/updates. -ate, tanks shall be factory assembled or assembled In tributlon facility by a certified representative of the turer, shall be identified by the manufacturer with the name or logo, capocitry and number of openings, and ctured,permanently marked at the inlet end of the tank. floors,roofs, and access covers shall resist an applied pounds per square foot (psf). oncrete covers and risers are not permitted on tanks,unless otherwise approved by the manufacturer. " practical,non-concrete IJA OHTS 4 septic tanks shall ed within groundwater.for installations that are placed g3g�WF� water,particular core must be token during fnstalication, �� backfilling to prevent damage to tank wools, and all n be sold by the manufacturer com fetel assembled. If, size,the tank 15 delivered to the site in sec'tiorros,oil p y sealed with watertight g�askets. All tanks shall be cater tightness after Instollation using a method the manufacturer and approved by the Department. g 9 5. v "a" he" ,.. u n tanks are installed in groundwater, the design ��I I MDNG shall submit buoyancy calculations to rove the Height � .f i y y p with or without anchoring or the addition of ballast) will 5.5 times more,thon the weight of the water displaced. 9 calculations shall be done using highest corded groundwater elevation with the tank empty. Sall of the tank(s) shall not be considered when the amount of anchoring or ballast weight required. SUEEOLK COUNTY HEALTH DEPARTMENT Ai=i='RO\/AL H.S. REFERENCE NO.: R-22-0400 , DAT E 7/8/2024 H , SS RE I,--- N10, R-24-0880 APPROVED � 51 �D7 PROJECTTITLEI t . , S�s56 r __ . , __ , �; _ ). _� 3 v 0% NMI" ME= emmt�,, il In rk I - i . I - r. rm" I __ I F11 1% It / O � - 5- /� I& 1 Bi %2% F 1, 11 , CE(k L N 0 Rl I Emmel t m i 0 .. CoHSULlrA I`lr2 E� s ARCHITECT OF RECORD: DAVID CHAGNON,ARCHITECTURAL DESIGN PLLC E-MAIL: DC-FILING@DCARCH-NY.COM "ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL IS ILLEGAL" PROPOSED NEW CONSTRUCTION 1 2050 NEW SUFFOLK/ 600 CEDARS ROAD , CUTCHOGUE , N .Y. 11935 ��* \ ��T FRONT ELEVATION SCOPE �� ���PROPOSEI OF WORK. ._0 A.�'l CRETE! DESIGN/BUILD GROUP�r *� p f f r4"• p d p c THIS APPLICATION PROPOSES A NEW RESIDENCE AT 2050 NEW ARCHITECTURE-ENGINEERING-CONSTRUCTION 3 ' ® .� �, t I ,rr k ", ,r�� t/ �� SUi OLK/ �'�00 CEDARS ROAp CUTCHOC�U N.Y. 11935 E-MAIL:MMUNOZ@CREATEDESIGNBUILDGROUP.COM c�"N"i- 7 A " I 19 , b �._'� �... t- __ . C � as _ __ _____ .__ -w._ p E, __ t-- _ ... ._... ._ _.cn, ._._.-.-_�_ 4 � .c TE L 631-464 6668 1 � Fi __.a__ w_.-.._ __.._. _ .._.__.... . ____ __ __ _._ _._ _..__.___ .__-... ____.__..__w � � .T_ y.___.m _ _ -_r____u _._...___.. _.____.__.__________.__.-._ .______.....____.._.__ _.I,--"= __ THIS NEU1 CONSTRUCTION INCLUDES MINOR RE-GRADING t THE SITE t1 41:1 iis ,) 4 0b �� � � L � � AND ALL NEW CONNECTIONS TO UTILITIES. i I i I . I . 0 � '%I,,% I � .411 1 . st xx A ' ! '� k 11 � `� �a - I.® �� � � V�. . � . . 4� � ca � DISCLAIMER s , ,-� -~• ® `. / D. �� 0 BUILDING PLAN REVIEUI NOTE; .BECKYSHEADESIGN �`" `Q i 0 t✓ j` �® ; a � BECKY@BECKYSHEA.COM �';�o �• � � =� ° �� - -A 1 �' � TOWN OF SOUTHOLD BUILDING PLANS EXAMINER /� to- . 4 4�► SHALL REVIr=W THE: ENCLOSED DOCUMENT FOR REVISION DATE DESCRIPTION 01 ' ; ..� =jiO.. _.�_ .__ A MINIMUM ACCEPTABLE PLAN SUBMITTAL _ a® � , `$� c --- __-___.- i ` I REQUIREMENTS OF THE TOWN OF SOUTHOLD AS #1 10.24.24 P.E. COMMENTS - ita - � _..____._ ____ • y 4LNI , .rIll SPECIFIEED IN THE BUILDING AND/OR RESIDENTIAL L Isi CODE OF THE STATE OF NEW `PORK. THIS REVIEW g 3 ,•�r� w. } ., zrz '`; F DOES NOT GUARANTEE COMPLIANCE WITH THAT CODE. #� ��d e THE SEAL AND SIGNATURE OF THE; DESIGN 0,.. CONSTRUCTION ADMINISTRATION BY: PROFESSIONAL HAS BEEN INTEERPRETEED AS AN • �► ATTESTATION TO THE BEST OF THE LICE:NSEE'S TO BE DETERMINED ' "w T I ON THAT, A► . . ft 4c BELIEF AND INFORMATION, THE WORK IN THE q _ - �' CLIENT: DATE: SCALE: as DOCUMENT IS: ALONZO FAMILY 12/24/22 AS SHObVN . -► �_ ACCURATE Q ' ; . ' % - '� +� - `` 67)r CONFORMS WITH GOVERNING CODES APPLICABLE CLIENT/ADDRESS/SCOPE OF WORK ° °5 4 AT THE TIME: OF SUBMISSION. .,, C FO M` �,, ,�W. �l' I#*-' 1+• . ON FORMS S WITH REASONABLE_ STANDARDS OF I I I". . , . . * ---.-]IL----J -----Jl . . . I ti t' ` '�• ;�,�' PRACTICE AND WITH VIEW TO THE SAFEGUARDING - �;, •� �,. � • ,�Vl NAVI OF LIFE, HEALTH, PROPERTY' AND PUBLIC • t __r- +,• $�� UJ_ ELFARE, R E S I l" ' E R ' C E ..' O4r.., i..� k'`Sa"•` .,,,:..W-Tres:" w� ' �. "I * 15 TT-I' � O \7 RE P N IBILI TY OF THE LICENSE=E;. BUILDING CODE NOTES T��s2 a�,a N��;"�s�r�t���°p�1�T°�THE �p�� CODE AND ��E 2020 LEXIST P� BU�DINGONAL CODE JUDGMENT NE=_UJY'ORK STATE:. PLIANCE WITH CLIMACTIC_ AND GEOGRAPHIC DESIGN CEDARS ROAD CUTCHOGUE N.Y. • (S) 16.PROVIDE COPPER TERMITE SHIELD AND SILL SEALER. PROVIDE PROTECTION OF WOOD and WOOD BASED P 5. HEATING AND AIR CONDITIONING REQUIREMENTS SHALL BE COORDINATED WITH THE C 29. ROOF AND VALLEY FLASHING TO BE INSTALLED AS PER R905. 2. 8 FLASHINGS. FLASHING ) 1. THE ARCHITECT / ENGINEER Of RECORD AND CONSULTANTS HAS NOT BEEN RETAINED FOR THE PRODUCTS FROM DECAY ON ENDS OF GIRDERS ENTERING MASONRY or CONCRETE ON BOTTOM and 1/2" on OWNER'S H.V.A.C. CONTRACTOR PRIOR TO COMMENCING ANY WORK. � ( ) FOR ASPHALT SHINGLES SHALL COMPLY WITH THIS SECTION. FLASHING SHALL BE APPLIED TABLE FW12(U CLIMATIC:AND GEO RAP1410 DESIGN CRTERA-(SPVIJC CQINIY) SUPERVISION OF THIS PROJECT. SIDES and END AS PER R317. (P) 6. PLUMBING SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS IN ACCORDANCE WITH THIS SECTION AND THE ASPHALT SHINGLE MANUFACTURER'S WIND DESU4 S9mCr TO DAMAGE mWM (S) 17. THE EXTERIOR SURFACE OF ALL FOUNDATION WALLS BELOW GRADE (EXCEPT SLAB AREAS) SHALL BE: OF CHAPTERS 23-33 OF THE 2020 NYS RESIDENTIAL CODE. GRolrm EEIOMIC F"T WINTER ICE CHEW AIR ) 2. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FILE FOR AND OBTAIN ALL DAMP-PROOFED WI AN ELASTIC COAL TAR BASE, SELF PRIMING BITUMINOUS PLASTIC CEMENT. PRINTED INSTRUCTIONS. R905. 2. 8. 1 BASE AND CAP FLASHING. BASE AND CAP SNOW SPEED oPoc,RaPNIe ePECIALumm nIIND-SoralE. M1614 LINE DESK UNDER-AYMENT FLooD , FREEZ6JGMEM ANT" REQUIRED APPROVALS AND PERMITS FROM ANY AND ALL GOVERNING AGENCIES HAVING PROVIDE PERIMETER RIGID INSULATION TO CODE AT ALL FOUNDATION WALLS. (P) 7. MECHANICAL SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS FLASHING SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION LOAD �+) mcm REGION DESKS ZONE C ,Tv.oRr, MAnaRMG• DEPTH^ TEIIHM• TEMP. FEQUIT;ED `AZARDbi °mDc T"I NEW RES I D E N C E JURISDICTION OVER THIS PROJECT. �S) 18. BEARING PLATES SHALL BE PROVIDED FOR STEEL RESTING ON MASONRY. OF CHAPTERS 12-23 OF THE 2020 NYS RESIDENTIAL CODE. INSTRUCTIONS. BASE FLASHING SHALL BE OF EITHER CORROSION-RESISTANT METAL OF 20 POP W'ALT NO No I MILE FROM COAST a BEVEL SCP 3 MOD To YE8 CAI.THE PLANS bm bill F 3. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL • • (P) 8. FUEL GAS SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS MINIMUM NOMINAL 0.019-INCH 0.483 MIA THICKNESS OR MINERAL-SURFACED ROLL ROOFING AND i m ISLAM FT M' WAVY EXAMIN�RB MM S 19. MINIMUM STEEL PROTECTION 3 4 FOR SLABS, 1 FOR INTERIOR FACE WALLS, 1-1 2 FOR BEAMS AND ( ) r • OF CHAPTER 24 OF THE 2020 NYS RESIDENTIAL CODE. WEIGHING A MINIMUM OF 77 POUNDS PER 100 SQUARE FEET (3.76 KG/M2). CAP FLASHING CODE AND ALL OTHER APPLICABLE CODES, LAWS, RULES AND REGULATIONS IN THE CONSTRUCTION GIRDERS, 2 FOR COLUMNS AN EXTERIOR FACE OF WALLS 3 FOR FOOTINGS, PIES AND PEDESTAL`S. TABLE R301.20)CUMATIC AND GEOGRAPHIC DESIGN CRITERIA-(SUMX.K COUNTY) OF' THIS PROJECT. (S) 20. WELD BASE PLATE TO COLUMN, PROVIDE (4) 12' LONG 37e DIA. (A307) ANCHOR BOLTS. WELD PLATE TO (P) 9. THE LICENSE PLUMBER, ELECTRICIAN, AND HVAC CONTRACTOR OF RECORD SHALL DETERMINE SHALL BE CORROSION-RESISTANT METAL OF MINIMUM NOMINAL 0.019-INCH (0.483 MM) " / " THE MODIFICATIONS AND/OR REPLACEMENT OF THE EXITING SYSTEM. ELEVATION LAT. WINTER SUMMER CO(NMG ALTITUDES INDOOR DESIGN TEMP TEMPERATURE TEMDESIGN PERATURE ARCHITECTURAL SEAL: ARCHITECT OF DAVID CHA NONECORD: 4. THE CONTRACTOR SHALL VERIFY AND BE: RESPONSIBLE FOR ALL FIELD DIMENSIONS AND TOP OF COLUMN, PROVIDE (4) 3/4 DIA. (A325) BOLTS. STEEL FLITCH PLATE TO BE BOLTED WITH 5�8 DIA. � THICKNESS. R905. 2. 8. 2 VALLEYS. VALLEY LININGS SHALL BE INSTALLED IN ACCORDANCE HEAnIRc FACTGR EXISTING CONDITIONS. THE CONTRACTOR SHALL REPORT ANY DISCREPANCIES IN THE BOLTS WITH WASHERS, 16' O.C. STAGGER TOP AND BOTTOM, (2) BOLTS 12' FROM EACH END. ALL MAILERS (P)10. LINO PLUMBING TO BE 1 EXTERIOR WALLS. WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS BEFORE APPLYING SHINGLES. ^ G DIFFERENCE A F RED A& DESIGN PLLCRAL EXISTING CONDITIONS FROM THOSE SHOWN ON THE CONTRACT DOCUMENTS TO THE ARCHITECT TO BE BOLTED WITH 1/2' DIA. GALV. THROUGH BOLTS WITH WASSHHERS 016' O.C. STAGGER TOP AND CORAP F,,NTS I CLADDI16 / FINISH NOTES-, VALLEY LININGS OF THE FOLLOWING TYPES SHALL BE PERMITTED: toe F 4i N ts^F Bs^F t.00 70^F 7s^F Bs^F �G CL/ E-MAIL: / ENGINEER OF RECORD SO THAT CORECTiVE STEPS CAN BE TAKEN. BOTTOM, PROVIDE BLOCKING AS NECESSARY. WIND VELOCITY WIND VELo7TY �5 -�R1C/, T , DC FILINGQDCARCH-NY.COM (C) 1. ALL WINDOWS AND SLIDING GLASS DOORS TO BE AS MANUFACTURED BY ANDERSEN OR EQUAL, A. FOR OPEN VALLEYS (VALLEY LINING EXPOSED) LINED WITH METAL„ THE VALLEY COOUNC TEMPERATURE DFFERENCE COINCIDENT NET DAILY WINTER SUMMER 0 P , C,y - ) 5. THESE DRAWINGS DO NOT INCLUDE COMPONENTS NECESSARY FOR CONSTRUCTION SAFETY. CONTRACTORS (S) 21. IF REQUIRED IT IS THE CONTRACTORS RESPONSIBILTY TO VERIFY BY A SOL TEST, A MINIMUM SOIL BEARING PERMASHIELD WITH INS LATED CLASS SCREENS AND LOCKS. SIZES AND TYPES AS SHOWN ON PLANS. HEATING COOLMIG BULB RANGE HUMIDITY HUMIDITY lV Q `� .l ARE SOLELY RESPONSIBLE FOR SUCH COMPONENTS. CAPACITY OF 2,000 LB. / SQ. FT AS PER ( R401.4.1 )(CHAPTER 4 OF THE 2020 NYSRC LINING SHALL BE AT LEAST 24 INCHES WIDE AND OF ANY OF THE CORROSION 4 1„ .t�.� Ar90 ( , ALL GLAZING WITHIN 18 FROM FINISf� FLOOR TO BE SAFETY GLASS -RESISTANT METALS IN TABLE R905. 2. 8. 2 n^F i5 MPH 7.8 MPH 72"F MEDIUM(M) 40 z 32 cxR o soz RH , 6. ALL UNNOTED OR NON-VISIBLE EASEMENTS ARE THE RESPONSIBILITY OF THE OWNER/BUILDER. (S) 22. FOUNDATION WALLS TO 11E INTO EXISTING WALLS WITH 15 RODS AT 18 O.C. VERTICAL DRILLED DOWN AT (C) 2. ALL EXTERIOR DOORS TO BE INSULATED METAL AS MANUFACTURED BY BENCHMARK, STANLEY OF EQUAL w 11 ; G 7. OWNER/BUILDER RESPONSIBLE FOR ALL INSPECTIONS, APPROVALS, CERTIFICATES, CERTIFICATES OF 45 DEGREES (AND GROUTED IN) INTO EXISTING FOUNDATION WALLS. RODS TO EXTEND INTO NEW AND UNLESS OTHERWISE NOTED. SIZES AND TYPES AS PER PLANS. B. FOR OPEN VALLEYS, VALLEY LINING OF TWO PLIES OF MINERAL SURFACE ROLL ROOFING, * ++I a O * OCCUPANCY OR COMPLETION, OR U.L APPROVAL EXISTING WALLS 8 MINIMUM. (C) 3. ALL EXTERIOR WALLS AND ROOF SHALL BE INSULATED WITH FIBERGLASS BATT TYPE INSULATION WITH COMPLYING WITH ASTM D 3909 OR ASTM D 6380 CLASS M, SHALL BE PERMITTED. CLIMACTIC GEOGRAPHIC DESIGN CRITERIA ^ P;=;;'` 8. ALL WORK SHALL BE GUARANTEED FOR ONE YEAR AFTER C.O. IS ISSUED. (S) 23. ALL STRUCTURAL STEEL FABRICATION AND ERECTION, INCLUDING ALL CONNECTIONS, SHALL INTEGRAL VAPOR BARRIER ON WARM SIDE .CARE SHOULD BE TAKEN NOT TO PUNCTURE VAPOR BARRIER THE BOTTOM LAYER SHALL BE 18 INCHES AND THE TOP LAYER A MINIMUM OF TO E6TA5LISH FLOOD HAZARD AREAS, EACH COMMUNITY REGULATED UNDER TITLE IS, PART 1203 ��` 042r E:� .. )) 9. OWNER IS RESPONSIBLE FOR FINAL SURVEY AND COSTS AS REQUIRED BY BUILDING DEPARTMENT. CONFORM TO LATEST A.I.S.C. SPECIFICATIONS, C 4. R-VALUES ARE SHOWN ON DRAWINGS. 36 INCHES WIDE. 9 83g O OF THEOFFICIAL COMPILATION OF CO S (S) 24. ALL SYMMETRICAL SECTIONS DESIGNED FOR ALLOWABLE UNIT STRESS (Fb) of 24,000 P.S.I. �C3 5. ALL SOFFITS AND FASCIA TO BE FRAMED WITH EXTERIOR GRADE WOOD, COVER WITH ALUMINUM OR VINYL C. FOR CLOSED VALLEYS (VALLEY COVERED WITH SHINGLES), VALLEY LINING OF ONE PLY OF SMOOTH ROLL ROOFING LDE RULES AND REGULATIONS OF THE STATE 01= F 4 10. NIO CONSTRUCTION OR DEMOLITION SHALL COMMENCE PRIOR TO THE ISSUANCE OF THE NON-COMPACT SECTIONS DESIGN FOR 22,000 P.S.I.. ALL OTHER SECTIONS DESIGN FOR 22000 P.S.I. (PROVIDE VENTILATION CONTiNUOUS VENTILATION AT CATHEDRAL CEILINGS). COMPLYING WITH ASTM D 6380 AND AT LEAST 36 INCHES WIDE OR VALLEY LINING AS DESCRIBED IN ITEMS 1 NEW YORK (NYCRR) SHALL ADOPT A FLOOD HAZARD MAP AND SUPPORTING DATA. THE FLOOD OF N✓� "ALTERATION OFTHIf;DOCUMENT BUILDING PERMIT. S 25.(ALL FIELD CONNECTIONS SHALL BE A MINIMUM OF 5/8' DIA. BOLTS (A325). SHOP CONNECTIONS TO (C)6. CONSTRUCTiON AS NOTED COMPLIES WITH ENERGY CONSERVATION AND CONSTRUCTION CODE of NEW AND 2 ABOVE SHALL BE PERMITTED. SELF ADHERING POLYMER MODIFIED BITUMEN UNDERLAYMENT COMPLYING HAZARD MAP SHALL INCLUDE, AT A MINIMUM, SPECIAL FLOOD HAZARD AREAS AS IDENTIFIED EXCEPT BYA LICENSED ( ) PROFESSIONAL IS ILLEGAL" ) 11. ALL LUMBER IS TO BE A MINIMUM OF DOUG FIR CONSTRUCTION Fb=1000 FOR REPETITIVE YORK STATE CONSTRUCTION OF THIS PROJECT. WITH ASTM D 1970 SHALL BE PERMITTED IN UEU of THE LINING MATERIAL. MEMBERS WITH E = 1.4 OR BETTER. BE BOLTED OR WELDED. BY THE FEDERAL EMERGENCY MANAGEMENT AGENCY IN THE FLOOD INSURANCE STUDY FOR ALL INTERIOR DOORS ARE TO CONFORM WITH THE INTERNATIONAL ) 12. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO SAFE GUARD THE EXISTING (S) 26. ALL WELDING SHALL CONFORM TO A.I.S.C. AND A.W.S. SPECIFICATIONS. (C) 7. AL RESIDENTIAL CODE. (C)30. PROVIDE DRIP EDGE AT EAVES AND GABLES OF SHINGLE ROOFS. OVERLAP TO BE A THE COMMUNITY, AS AMENDED OR REVISED WITH: (C) 8. WINDOWS AND DOORS SHALL. BE PROPERLY FLASHED AT HEADS AND PROPERLY SEALED AND MINIMUM OF 2 INCHES (51 MM). EAVE DRIP EDGES SHALL EXTEND 0.25 INCH (6.4 MM) BELOW RESIDENCE AND CONTENTS AGAINST DAMAGE FROM THE ELEMENTS DURING CONSTRUCTION. FRAMING NOTES: WEATHER-STRIPPED. r ) 13. THE CONTRACTOR SHALL REPAIR ALL EXISTING CONDITIONS DAMAGED DUE TO THE (F) 1. ALL HEADERS TO BE SUPPORTED BY 4'X 4" POSTS UNLESS OTHERWISE NOTED. (C) 9. ALL GLAZING WITHIN 36' FROM THE TOP OF STAIRS AND LESS THAN 60' FROM WALKING SURFACE SHEATHING AND EXTEND BACK ON THE ROOM A MINIMUM OF 2 INCHES (.rl MM). DRIP EDGE I. THE ACCOMPANYING FLOOD INSURANCE RATE MAP (FIRM), EXECUTION OF THIS WORK TO ITS ORIGINAL CONDITION. 2. (2) 2 x 8 HEADERS OVER OPENINGS UNLESS OTHERWISE NOTED. TO HAVE SAFETY GLAZING, AS PER SECTION R308A. SHALL D MECHANICALLY FASTENED A MAXIMUM OF 12 INCHES (305MM) ON CENTER. A CRICKET II. FLOOD 5OUNDARY AND FLOODWAY MAP (F5FM), AND 14. THE DRAWNGS ARE NOT TO BE SCALED - FOLLOW DIMENSIONS ONLY. OR SADDLE SHALL BE INSTALLED ON THE RIDGE SIDE OF ANY CHIMNEY GREATER TITAN 30 INCHES) 15. TH CHANGES WILL BE PERMITTED WITED -PRIOR WRITTEN NOTIFICATION OF AND �F) F 3. DOUBLE UP JOISTS UNDER ALL PARALLEL PARTITIONS & AROUND ALL OPENINGS, SUCH AS STAIRS (C) 10. ALL GLAZING IN DOORS AND DICLOSURES FOR HOT TUBS, WHIRLPOOLS, BATHTUBS, AND WIDE. CRICKET OR SADDLE COVERINGS SHALL BE SHEET METAL OR OF THE SAME MATERIAL AS III. RELATED SUPPORTING DATA ALONG WITH ANY REVISIONS THERETO. APPROVAL OF THE ARCHITECT/ ENGINEER OF RECORD. AND SKYLIGHTS. DOUBLE JOIST UNDER ALL POSTS. SHOWERS TO BE SAFETY GLAZING, AS PER SECTION R308.4. (F) 4. ALL INTERIOR BEARING PART1110NS TO BE SOLID BLOCKt 0 AT MID SPAN OF WALL MINIMUM BEARING ROOF COVERING. THE ADOPTED FLOOD HAZARD MAP AND SUPPORTING DATA ARE HEREBY ADOPTED BY (C) 11. ALL GLAZING (WINDOWS) WITHIN BATHROOM FIXTURE ENCLOSURES TO HAVE SAFETY GLAZING, (C) 31. ALL NAILERS TO 13E BOLTED WITH V DIA. (GALVANIZED AT EXTERIOR) THROUGH BOLTS WITH WASHERS REFERENCE AND ) 16. CONTRACTOR SHALL PROVIDE THE OWNER WITH A CERTIFICATE OF OCCUPANCY AND AN FOR JOISTS TO BE 3 1/2' ON INTERIOR. AS PER SECTION R308.4. • ELECTRICAL CERTIFICATE FROM AN APPROVED AGENCY UPON COMPLETION OF THIS PROJECT. F 5. FOR HEADERS OVER 5'-0' LONG USE DOUBLE JACK STUDS. �C� 12. ALL CLOSET SHELVES TO BE CLEAR PINE UNLESS OTHERWISE NOTED. ® 16 O.0 STAGGER TOP AND BOTTOM, PROVIDE BLOCKING AS NECESSARY; PROVIDE FLASHING AT DECLARED TO SE PART OF THIS SECTION. 17. ALL WALLS DESIGNATED TO BE REMOVED ARE ASSUMED 1T) BE BEARING WALLS AND THE ( • TOP OF EXTERIOR NAILERS. THE GROUND SNOW LOADS TO DE USED IN DETERMINING THE DESIGN SNOW LOADS FOR ROOFS ARE DOB EMPLOYEE STAMPS AND SIGNATURES F 6. PROVIDE SOLID BRIDGING FOR WOOD JOISTS, MAX. 8-0 O.C. C 13. PROVIDE 1 1/4 WOOD CLOTHES ROD IN ALL CLOSETS. (C) 32. R905. 2. 5 FASTENERS. FASTENERS FOR ASPHALT SHINGLES SHALL BE GALVANIZED STEEL, GIVEN IN FIGURE R301.2(5) FOR SITES AT ELEVATIONS UP TO 1000 FEET. SITES AT ELEVATIONS SURROUNDING AREAS MUST BE SHORED AND BRACED PRIOR TO ANY REMOVAL �F 7. ALL CAP PLATES TO BE DOUBLED, AND NAILED WITH 10D NAILS AT 12' O.C. C 14. PROVIDE GUTTERS & LEADERS, GUTTERS TO BE SEAMLESS TYPE:, LEAD RAINWATER AWAY FROM FOUNDATION. STAINLESS STEEL, ,ALUMINUM OR COPPER ROOFING NAILS, MINIMUM 12 GAGE 0.105 INCH (2.67 MM) SHANK A50VE 1000 FEET SHALL HAVE THEIR GROUND SNOW LOAD INCREASED FROM THE MA P D VA ) 18. ALL DESIGNS/DRAWINGS ARE PENDING APPROVAL OF ALL CONCERNED GOVERNMENTAL F 8. ALL WOOD FRAMING TO BE MINIMUM OF 8 ABOVE GRADE. 15. EXTERIOR STEPS AND LANDING, IF 18 OR MORE ABOVE GRADE TO HAVE HANDRAIL R P E LUE AUTHORITIES. NO WORK TO BEGIN UNTIL ALL REQUIRED APPROVALS HAVE BEEN OBTAINED. F 9. ALL INTERIOR WALLS TO BE FRAMED WITH 2' X 4' STUDS ® 16' O.C. �C� C 16. ALL GYPSUM SHALL BE TAPED AND SPACKLED (3 COATS) READY FOR PAINT. 1/2 INCH SHEETROCK FOR NTH A MINIMUM 3/8-INCH (9.5 MM) DIAMETER HEAD, ASTM F 1667, OF A LENGTH TO PENETRATE BY 2 PSF FOR EVERY 100 FEET ENGINEER AND CONSULTANTS ASSUMES NO RESPONSIBILITY FOR DELAYS IN APPROVALS BY THE F 10. PROVIDE SOLID BLOCKING UNDER ALL POSTS BETWEEN FLOORS TO TOP OF FOUNDATION WALL. ALL WALLS & CEIUNG'S. 5/8 TYPE X FOR ALL GARAGE AND MECHANICAL ROOMS. 1/2 INCH M/R GREENBOARD THROUGH THE ROOFING MATERIALS AND A MINIMUM OF 3/4 INCH (19.1 MIDI) INTO THE ROOF SHEATHING. ABOVE 1000 FEET. ABOVE ME:NTiONED AUTHORITIES. IF 11. ALL SHEATHING SHALL BE 1/2' CDX EXTERIOR GRADE PLYWOOD, NAILED WITH 8d COMMON NAILS CI 6' O.C. FOR ALL BATHROOMS. WHERE THE ROOF SHEATHING IS LESS THAN 3/4 INCH (19.1 MM) THICK, THE FASTENERS SHALL CLIMATE ZONE 15 4A 19. CONTRACTOR SHALL DISCONNECT , CAP AND RE-ROUTE ANY EXISTING WATER, SANITARY OR AT PANEL EDGES AND ®INTERMEDIATE SUPPORTS IN THE PANEL FIELD OR FOLLOW NAILING SCHEDULE. (C) 17. ALL FINISHES SHALL BE AS DIRECTED BY OWNER. PENETRATE THROUGH THE SHEATHING. FASTENERS SHALLCOMPLY WITH ASTM F 1667. INTERIOR SPACES INTENDED FOR HUMAN OCCUPANCY SHALL 5E PROVIDED WITH INDOOR UTILITY LINES IN AREA OF NEW FOUNDATION (CONSTRUCTION) AND SHALL USE HAND PROVIDE SOLID BLOCKING AT ALL SHEATHING EDGES. (C) 18. RATED PARTITIONS TO HAVE TOP AND BOTTOM EDGES PROPERLY SEALED WITH ALL GYPSUM BOARD (C) 33. R905. 2. 6 ATTACHMENT. ASPHALT SHINGLES SHALL HAVE THE MINIMUM NUMBER OF FASTENERS REQUIRED EXCAVATION IN AREAS OF SUSPECTED UNDERGROUND UTILITIES AND SERVICES. IF ANY LINES (F) 12. ALL SUB-FLOORS TO BE 3/4' PLYWOOD NAILED WITH 8D ®6' O.C. BY THE MANUFACTURER. FOR NORMAL APPLICATION, ASPHALT SHINGLES SHALL BE SECURED TO THE ROOF TEMPERATURE OF NOT LESS THAN - AF;E BROKEN OR DAMAGED, THE CONTRACTOR WILL REPAIR AND REPLACE SAME AT HIS OWN F 13. ALL WALL CORNERS TO BE MIN. THREE STUDS NAILED WITH 10D NAILS AT 12 O.C. PANEL JOINTS PROPERLY TAPED AND SPACKLED,NFIRE (3) COATS. (2 15 IMC ES FARENHEIT AT A POINT FEET ABOVE THE FLOOR ON THE DESIGN HEATING DAY C SELF-CLOSING WITH NOT LESS THAN FOUR FASTENERS PER STRIP SHINGLE OR TWO FASTENERS PER INDIVIDUAL SHINGLE. 19. ANY DOOR AND FRAME LOCATED WITHIN A FIRE RATED PART1TlON TO BE SELF CLOSIN( AND FIRE RATED( ) � 12015 IMG 309.1) EXPENSE AND ARRANGE FOR PROPER INSPECTION OF HIS WORK. F 14. BLOCK STUD WALLS AT HALF STORY HEIGHTS AND UNSUPPORTED EDGES OF PLYWOOD. WHERE THE ROOF .)LOPE EXCEEDS 20 UNITS VERTICAL IN 12 UNITS HORIZONTAL (167 PERCENT), SPECIAL : 1 F 15. ALL NAILS, BOLTS, AND FRAMING HANGERS TO BE HOT DIPPED GALVANIZED. AT 45 MINUTES MINIMUM. FIRE RATING TO BE CLEARLY INDICATED BY APPROVED TESTiAG ORGANIZATION METHODS OF FASTENING ARE REQUIRED. FOOR ROOFS LOCATED WHERE THE BASIC WIND SPEED IS 110 MPH SYTEM DESIGN SHALL 5E BASED ON MAX '12 DEGREES HEATING, MINIMUM '15 DEGREES COOLING DEC 1 3 r_;;_,, 20. ENGINEER AND CONSULTANTS SHALL NOT HAVE CONTROL OVER OR CHARGE OF AND SHALL NOT �F i6. ALLOW A MINIMUM OF 18' BETWEEN BOTTOM OF FLOOR JOIST AND TOP OF SCREED COAT ON THE DOOR EDGE AS PER SECTION R302. • OR HIGHER, SPECIAL METHODS OF FASTENING ARE. REQUIRED SPECIAL FASTENING METHODS SHALL BE TESTED DEGREE DAYS (NY LAGUARDIA) 4811, WINTER DESIGN TEMP 15, DRY 5ULB Be, WET BULB '15 12015 BE RESPONSIBLE FOR SAFETY CONSTRUCTION PRE MEANS, METHODS, TECHNIQUES, SEQUENCES OR OR PROVIDE 30 YEAR PRESSURE TREATED LUMBER ACQ. (C) 20. EXISTING PARTITIONS WITHIN FIFE RATED ENCLOSURES TO RECEIVE ONE LAYER OF 5/8' THICK TYPE X PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK, ( ) / IN ACCORDANCE NTH ASTM D 3161, CLASS F. ASPHALT SHINGLE WRAPPERS SHALL BEAR A LABAL INDICAIiNG IPC APPDX D) SINCE THESE ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. THE ENGINEER AND (F) 17. PROVIDE DOUBLE HEADERS AT ALL FLOOR, CEILING, STAIR AND ROOF OPENINGS. ALL FIRECODE GYPSUM WALLBOARD PROPERLY FASTENED WITH ALL JOINTS PROPERLY SEALED, TAPED, COMPLIANCE WITH ASTM D 3161, CLASS F. ALSO AS PER 2015 IBC CHAPTER 16 SECTION 160E AND ASCE I - WIND EXPOSURE CATEGORY HEADERS TO BE A MINIMUM OF 2 2 x 8 UNLESS OTHERWISE NOTED ON PLANS. AND SPACKLED AS PER SECTION R302. 34. IF PROPERTY IS IN WIND-BORN DEBRIS REGION ALL GLAZED OPENINGS SHALL AND SURFACE ROUGHNESS IS B. USE C FOR BOTH CONSULTANTS SHALL NOT 8E RESPONSIBLE FOR THE CONTRACTOR'S SCHEDULE OR FAILURE TO O (C) CARRY OUT WORK IN ACCORDANCE WITH 'THE CONTRACT DOCUMENTS. THE ARCHITECT SHALL (F 18. FLOOR JOISTS SHALL BE DOUBLED BENEATH ALL PARALLEL PARTITIONS OR BLOCK ® 16' O.C. (C) 21. RATED CEILINGS TO HAVE ONE LAYER OF 5/8' THICK TYPE'X' FIRECODE GYPSUM WALLBOARD PROPERLY HAVE IMPACT RESISTANT GLASS AS PER (SECTION R301. 2. 1. 2), SOUTH SHORE AND FIRE ISLAND. NOT HAVE CONTROL OVER OR CHARGE OF ACTS OR OMISSIONS OF THE CONTRACTOR, 19. STAIR TREADS SHALL BE 1 1/4' THICK CLEAR OAK, UNLESS OTHERWISE NOTED. FASTENED WITH ALL JOINTS PROPERLY SEALED, TAPED, AND SPACKLED AS PER SECTION R302. (OR) TOWN OF DABYLON IS WITHIN A HURRICANE PRONE REGION .�SUBCONTRACTORS OR THEIR AGENTS OR EMPLOYEES, OR ANY OTHER PERSONS PERFORMING �F) F 20. ALL STAIRS SHALL BE IN ACCORDANCE WITH (SECTION R311, R312 and R308.4.6). (C) 22. ALL CLOSET INTERIORS BY OWNER. CONTRACTOR TO PROVIDED ADEQUATE BLOCKING FOR OWNER PROVIDE WOOD STRUCTURAL PANELS OVER ALL GLAZED OPENINGS AS PER INSTALLED CLOSET INTERIOR. SECTION R301. 2. 1. 2), (EXCEPTION) OF THE RESIDENTIAL CODE OF NEW YORK STATE. SHEET TITLE PORTIONS OF THE WORK. ( C PROVIDE AR A N SPACKLED, EA FOR A 23. R E 1 2 GYPSUM WA1160 D AT ALL WALLS, TAPED AND S AC LED 3 COATS READY 0 PINT 21. THE ENGINEER AND CONSULTANTS ASSUMES NO RESPONSIBILITY FOR PRE-EXISTING VIOLATIONS, F 21. DOUBLE ALL JOIST AROUND FLOOR, CEILING, AND ROOF OPENINGS, USE JOIST HANGERS. ( ) �i • ' ( ) VANITIES, WOOD STRUCTURAL PANELS SHALL HAVE A MINIMUM THICKNESS OF 7/16 INCH AND A TABLE R 401.4.1 ALL LUMBER TO BE A MINIMUM OF DOUG FIR CONSTRUCTION NUMBER 2 OR F 22. ALL WOOD CONSTRUCTION CONNECTORS TO BE FROM SIMPSON STRONG-TiE OR EQUAL UNLESS OTHERWISE NOTED. INSTALL WONDERBOARD BEHIND AND AROUND TUBS, TOILETS, TiES, MAXIMUM SPAN OF 8 FEET. PANELS SHALL BE PRECUT SO THAT THEY SHALL BE CODE/ZONING DEFICIENCIES AND/OR NON--CONFORMING USAGE'S. LOAD-BEARING BETTER. MINIMUM Fb 1000P.S.1. ) 22. THE PROPOSED ADDITION SHALL NOT CAUSE THE EXISTING MECHANICAL SYSTEM (HEATING AND F) 23. ALL EXTERIOR WOOD CONNECTORS TO BE HOT-DIP GALVANIZED (HDG). AND WASHER/DRYER AREA. ATTACHED TO THE FRAMING SURROUNDING THE OPENING CONTAINING THE PRODUCT PRESSURE F 24. WALL CONSTRUCTION WFCM PRESCRIPTiVI- METHOD WALL FRAMING AND FINISHING (C)24. INSTALL OWNER SUPPLIED CERAMIC TiLE AT NEW BATHROOM FLOORS, 48 AT WALLS AND FULL HEIGHT WITH GLAZING OPENING. PANELS SHALL BE SECURED WITH NO. 8 SCREWS AT 12 O.C. CLASS OF MATERIAL (pounds per sq. ft.) TO PREVENT GALVANIC CORROSION ALUMINUi AND COPPER SHALL NOTBE IN DIRECT PLUMBING) AND ELECTRICAL TO BECOME UNSAFE, INSANITARY OR OVER LOADED. SHALL BE NAILED AND OR SCREWED IN ACCORDANCE WITH TABLE 3.1 WFCM 2015 EDITION. PAGE 149 AROUND TUBS. TiLE AT FLOOR TO BE THIN SET ON 3/4' EXTERIOR PLYWOOD (B/C) SUBSTRATE OVER MINIMUM 1 1/4' PENETRATION INTO THE WALL FRAMING AT OPPOSING ENDS. CRYSTAWNE BEDROCK i2,000 CONTACT WITH EACH OTHER, THIS INCLUDES COPPER PRESSURE TREATED WOOD (ACQ). 23. THE CONTRACTOR SHALL PROVIDE ALL REQUIRED INSURANCE AND INSURANCE CERTIFICATES (F) 25. FLOOR CONSTRUCTION- WFCM PRESCRIPTIVE METHOD FLOOR FRAMING SHALL BE SUB-FLOOR. PROVIDE MARBLE SADDLE AT DOOR. (C) 35. ALL NEW WINDOWS SHALL HAVE A MINIMUM (DP) DESIGN PRESSURE RATING OF 30. SEDIMEi4TARY and FOLIATED ROCK 4,000 and OTHER COPPER WOOD TREATMENTS. WHERE USED (IE: PLATES and SILLS IN Q0 ICRETE & STEEL NOTES: NAILED IN ACCORDANCE WITH TABLE 3.1 WFCM 2015 EDITION. PAGE 149 (C)25. NEW INTERIOR WALL TO BE 1/2' GYPSUM WALLBOARD ON 2 x 4 FRAMING, 16' O.C. (C) 36. PROVIDE JAMB CUPS AS PER MANUFACTURES SPECIFICATIONS AND SANDY GRAVEL and/or GRAVEL GW and GP 3,000 CONTACT WITH GRADE) ALL FASTENERS MUST E STAINLESS STEEL INCLUDING NAILS. 1. ALL CONCRETE TO BE 3000 PSI. 28 DAY TEST and MUST HAVE 5 to 7% AIR-ENTRAINMENT AS PER (R (F 26. DRAFTSTOPPING SHALL BE PROVIDED AS PER R502.12 and R302.12 (C)26. INSTALL NEW CONCEALED PULL DOWN LADDERS AT AT11C. EXACT LOCATION TO BE DETERMINED BY OWNER (SECTION R609.7) OF THE 2020 NYS RESIDENTIAL CODE. SAND, ! SAND, CLAYEY SAND, SILTY PROOF OF PRODUCT MUST BE SUBMITTED TO INSPECTOR AT JOB SITE. 402. 2). PROVIDE 5/8' DIAMETER x 12' LONG (7" PENETRATION INTO CONCRETE) with 3" SQ. (F) 27. FIREBLOCKING SHALL BE PROVIDED AS PER R 502. 13, R602.8 and R302.11. (C) 27. ROOFING UNDERLAYMENT TO BE INSTALLED AS PER R905. 1. 1 UNDERLAYMENT APPLICATION. (C) 37. IF SOLID 2" X 4- MULLION IS NOT INDICATED ON PLANS PROVIDE STEEL MULLIONS GRAVEL and CLAYEY GRAVEL 2 WASHER/PLATES ANCHOR BOLTS SPACED A MAXIMUM OF 32 INCHES O.C. ANCHOR BOLTS SHALL ALSO (F) 28. ROOF ASSEMBLIES- WFCM PRESCRIPTIVE METHOD FOR ROOF SLOPES FROM TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL (17-PERCENT SLOPE), ON ALL NEW WINDOWS (AS PER SECTION R609.8). (SW, SFI, SM, SC, GM, and GC) TITLE SHEET BE LOCATED WITHIN 12 INCHES FROM THE ENDS OF EACH PLATE SECTION. EXCEPTION: FOUNDATION ELECTRICAL NOTES-. UP TO FOUR UNITS VERTICAL IN 12 UNIT SHORIZONTAL (33-PERCENT SLOPE), UNDERLAYMENT ALL STRUCTURAL STEEL TO BE A36 STEEL AND SHALL CONFORM TO A.S.T.M. SPECS. CLAY, :RANDY CLAY, SILTY CLAY, CLAYEY C s�Lr, and SANDY SILT 1,500 CONTRACTOR TO VERIFY ALL EXISTING ANCHOR STRAPS, SPACED AS REQUIRED TO PROVIDE EQUIVALENT ANCHORAGE TO 1/2' DIAMETER SHALL BE TWO LAYERS APPLIED IN THE FOLLOWING MANNER. APPLY A MINIMUM 19-INCH S I D • ((� ML. MH, and CH) ANCHOR BOLTS AS PER (R 403. 1. 6) PORCHES, CARPORT SLABS, STEPS EXPOSED TO THE WEATHER 1. ELECTRICAL CONTRACTOR TO COORDINATE W/ OWNER & OTHER TRADES. WIDE (483 MM) STRIP OF UNDERLAYMENT FELT PARALLEL WITH AND STARTING AT THE: EAVES, UNDATIONS PRIOR TOTO BE 350OPSI AS PER (R 402. 2). FOOTINGS TO BEAR ONVIRGIN SOIL �E� E 2. ALL ELECTRICAL WORK IS TO COMPLY WITH NEW YORK STATE, NATIONAL ELECTRICAL CODES, R310.2 - MINIMUM OPENING AREA. ALL EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL T A B L E R 403.1 THE START OF CONSTRUCTION. BRING ANY FASTENED SUFFICIENTLY TO HOLD IN PLACE. STARTING AT THE EAVE, APPLY 36-INCH-WIDE AND NATIONAL FIRE PROTECTION ASSOCIATION. CONVENTIONAL OUTLETS TO BE 18' ABOVE FIN. HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET 2. BOTTOM OF EXTERIOR FOOTINGS AND/OR GRADE BEAMS 1'0 BE 3-0 MINIMUM BELOW GRADE. FLOOR UNLESS OTHERWISE NOTED. (914 MM) SHEETS OF UNDERLAYMENT OVERLAPPING SUCCESSIVE SHEETS 19 INCHES ,183 MM) EXCEPTION: GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5 LOAD-BEARING VALUE OF SOIL(PSF) DISCREPANCIES TO THE ATTENTION OF THE 3. SOIL COMPACTION TO BE NO LESS THAN 95% MODIFIED PROCTOR TEST. ELAND FASTENED SUFFICIENTLY TO HOLD IN PLACE. DISTORTIONS IN THE UNDERLAYMENT SHALL (E) 3. PROVIDE GROUND FAULT CIRCUIT INTERRUPTER OUTLETS AS PER CODE. NOT INTERFEREWITH THE ABILITY OF THE SHINGLES SEAL FOR ROOF SLOPES OF FOUR UNITS SQUARE FEET. DESIGN PROFESSIONAL 4. STEP FOOTINGS DOWN AS REQUIRED TO ONE SOIL. R310.2.1 - MINIMUM OPENING HEIGHT. THE MINIMUM NET OPENING HEIGHT SHALL BE 24 INCHES 1,Doo 2,ODo 3,000 4,000 5. MAXIMUM STEP OF FOOTINGS SHALL BE ONE VERTICALLY TO TWO HORIZONTALLY WHERE BOTTOM (E) 4. ALL ELECTRICAL OUTLETS, SWITCHES, LIGHTS AND WIRING SHALL BE U.L CERTIFIED VERTICAL IN 12 UNITS HORIZONTAL (33-PERCENT SLOPE) OR GREATER, UNDERLAYMENT SHALL �� HEATING, A/C, AND PLUMBING DOB NOW PROJECT NUMBER OF FOOTING ELEVATIONS CHANGE. AND INSTALLED IN COMPLIANCE WITH ALL APPLICABLE ELECTRICAL CODES. BE ONE LAYER APPLIED IN THE FOLLOWING MANNER. UNDERLAYMENT SHALL BE APPLIED SHINGLE R310.2.1 - MINIMUM OPENING WIDTH. THE MINIMUM NET CLEAR OPENING WIDTH SHALL BE 20 CONVENTIONAL LIGHT FRAME CONSTRUCTION CONTRACTOR TO FUROUT OR BOX OUT 6. ALL EXPOSED CONCRETE TO BE AIR ENTRAINED. (E) 5. THE CONTRACTOR SHALL RELOCATE ALL EXISTING ELECTRIC, TELEPHONE, ANTENNA AND FASHION, PARALLEL TO AND STARTING FROM THE EAVE AND LAPPED 2 INCHES, FASTENED R310.2.2 INCHES. RE EMERGENCY ESCAPE AND RESCUE OPENINGS ARE PROVIDED THEY SHRILL 1-STORY t2 1 12 12 WALLS AS NECESSARY TO RUN PIPES OR 7. FORMS TO REMAIN IN PLACE 3 DAYS MINIMUM. CABLE T.V. SERVICE WIRING AS REQUIRED. 8. PROVIDE SLEEVES IN FOUNDATION WALLS AS REQUIRED FOR ELECTRICAL, PLUMBING, (E) 6. ELECTRICAL SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS (C) 28. ICE BARRIER. IN AREAS WHERE; THERE HAS BEEN A HISTORY LE ICE FORMING ALONG THE HAVE A SILL HEIGHT OF NO MORE THAN 44 INCHES ABOVE THE FLOOR. 2-STORY 15 t2 12 12 BscaN EAVES CAUSING A BACKUP OF WATER AS DESIGNETED IN TABLE R301. 2(1), AN ICE BARRIER THAT DUCTS. IF NEEDED DRILL AND NOTCH MECHANICAL, ETC.. COORDINATE WITH OTHER CONTRACTORS, AGENCIES, ETC. AS REQUIRED. OF CHAPTERS 34-43 2020 INTERNATIONAL RESIDENTIAL CODE CONSISIT OF AT LEAST TWO LAYERS OF UNDERLAYMENT CEMENTED TOGETHER OR OF A $ A !ON MONOXIDE DETECTOR NOTES: 3-STORY 23 17 t2 tz STUDS AND PLATES AS PER SECTION 9. BACKFILL SHALL BE PLACED IN 12 LIFTS AND COMPACTED TO 95%MODIFIED PROCTOR DENSITY. (E) 7. INSTALL NEW EXHAUST FAN AT LOCATIONS NOTED. MINIMUM 50 CFM OR OTHERWISE NOTED. SELF-ADHERING POLYMER MODIFIED BITUMEN SHEET, SHALL BE USED IN UEU OF NORMAL SHALL BE INSTALLED i1S PER THE 2020 NYS RESIDENTIAL CODE - SECTION R314. 4-INCH BRICK VENEER OVER LIGHT FRAME or 8-INCH HOLLOW CONCRETE MASORNY R602. 6 TO R602. 6. 1 OF THE 2020 ) 10. SLABS ON GRADE SHALL BE MINIMUM 4 THICK 3000 PSI CONCRETE (INTERIOR) 3500 PSI CONCRETE EQUIPPED WITH METAL WEATHER HOOD, BACK DRAFT DAMPER AND INSECT SCREEN. UNDERLAYMENT AND EXTEND FROM THE LOWEST EDGE (EAVE) OF THE ROOF SURFACES TO A ALL SMOKE DETECTORS TO BE LINE VOLTAGE WITH BATTERY BACK-UP AND WIRED i-STORY 12 12 1 12-112 NYS RESIDENTIAL CODE. (EXTERIOR & GARAGE FLOORS) WITH 6'X6', 10/10 WELDED WIRE MESH. PROVIDE 6 MIL VAPOR BARRIER. FANS LOCATED IN WALLS TO UE FLAT (A MAXIMUM 2 EXPOSURE), THOSE MOUNTED IN POINT AT LEAST 24 INCHES (610 MIA) INSIDE THE EXTERIOR WALL LINE OF THE BUILDING. IN A MANNER SUCH THAT THE ACTIVATION OF ONE WILL ACTIVATE ALL EACH FLOOR 2-STORY 21 16 12 12 ) 11. ALL CURBS, SIDEWALKS, ETC. DAMAGED SHALL BE REPLACED. ROOF TO BE PROPERLY WEATHER-STRIPPED AND COUNTER FLASHED AS PER SECTION M1507. LEVEL TO HAVE AT LEAST ONE SMOKE DETECTOR. EACH BEDROOM TO HAVE ITS OWN ) 12. PITCH GRADE AWAY FROM BUILDING, STORM WATER IS NOT PERMITTED TO FLOW ONTO PLUMBG & MECHANICAL NO ►� SMOKE DETECTOR. ALL HALLWAYS ADJACENT TO BEDROOMS MUST HAVE A SMOKE DETECTOR. 3-STORY 32 24 is t2 ABUTTING PROPERTIES. �P� 1. PLUMBING CONTRACTOR TO COORDINATED W OWNER & OTHER TRADES, 8-INCH SOLID or FULLY GROUTED MASONRY 13. CONCRETE FOUNDATION WADS TO BE POURED MONOLITHIC. NO HORIZONTAL JOINTS SHALL BE PLACED / ALINE VOLTAGE CARBON MONOXIDE DETECTOR SHALL BE LOACTID AT EACH LEVEL OF IN WALLS WITHOUT THE WRITTEN APPROVAL OF THE ENGINEER OR ARCHITECT OF RECORD. P 2. BATHROOM AND KITCHEN FIXTURES TO BE AMERICAN STANDARD, KOHLER OR EQUAL THE DWELLING, INCLUDING A BASEMENT or CELLAR. 1-STORY 16 12 12 12 DRAWING No. SHEET No. ) 14. PROVIDE ACCESS & CROSS VENTS IN ALL. ATTICS & CRAWL SPACES, VENTS TO BE A MINIMUM 1 SO. FT. P 3. ALL PLUMBING WORK SHALL COMPLY TO THE: 2020 NYS RESIDENTIAL CODE AND ALL 1 OFI UNDER FLOOR AREA AS PER SECTION R408. OTHER APPLICABLE CODES, LAWS. RULES, REGULATIONS AND HEALTH DEPARTMENT REQUIREMENTS. 2-STORY 2s 21 t4 12 ) 15. ALL WOOD SILLS IN CONTACT WITH SOIL, MASONRY, OR CONCRETE TD BE PRESSURE TREATED, (P) 4. PROVIDE ALL NECESSARY VENTILATION (AIR INTAKE AND EXHAUST) AS PER 2020 NYS RESIDENTIAL CODE 3-sTTNtY 42 3z 2, ,s f m AS PER SECTION R317 AND R318. AND EQUIPMENT MANUFACTURES SPECIFICATIONS. OF 16 PROJECT "TITLE Bill= D N C ifk "LON cm= ARCHITECT OF RECORD: Rl I ZO % D,AVID CHAGNON,ARCHITECTURAL DESIGN PLLC E-MAIL: DC_FILING@DCARCH-NY.COM "ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL IS ILLEGAL" PROPOSED NEW CONSTRUCTION 2050 NEW SUFFOLK/ 600 CEDAR' ROAD , CUTCHOGUE , N . Y. 11935 PROPOSED, SITE PLAN : SCALE — 1 /3211 = 1 '-011 CREATE! DESIGN/BUILD GROUP ARCHITECTURE-ENGINEERING-CONSTRUCTION S.C.T.TV. DISTRICT 1000 SECTION 10 9 �L®�� 5 LOT � � E-MAIL:MMUNOZ@CREATEDESIGNBUILDGROUP.COM TEL:631-464-6668 AW DWELLING W/PUBLIC WATER MON. ®� p?ER 167.0� ';V'T _ cl� 3 39 50"E .�w Bg 13 .9 09'/ MON. i ` BECKY SHEA DESIGN �" QI BECKY@BECKYSHEA.COM JIPE yl VACANT v AGRICULTURAL REVISION DATE DESCRIPTION w I LAND N/F OF 150,+ #1 10.24.24 P.E. COMMENTS �S 4 GEORGIA TEDFROUS DWELLING W/PUBLIC WATER ' U.P z r ZONE X \ o 0 7_% CHANCE ANNUAL FLOOD \ 7 __ \\ y 7 \\ ,�+ CONSTRUCTION ADMINISTRATION BY: rn ,_ _ g ,6 \ \\ 192.08' MON.. \ N ° �,� TO BE DETERMINED ~�! / \\ N 86 2700 E<-5-- C / ON. O CLIENT: DATE: SCALE: \ N \ / O / J I \ \ \ ALONZO FAMILY 12/24/22 AS SHOWN .1- I \ \AREA OF MAINTfr1NED LAWN J /' / \ ;I) J� � RCLIENT/ADDRESS/SCOPE OF WORK 7, m , jTm � iV TA IDERiNG WERE FEJJCE /'%8.5'S Jc�/ \\ �6> .87 VE _s AftE VIVA Y LAND N/F OF / W I Z 9f, Qi ,' Im IL HEPNER & HENDERSON / ORCp m FRONT YARD~ �� S?/ DWELLING W/PUBLIC WATER W WqT / \ ZONE AE(EL 6) vv - 1 47.59' M CEDARS ROAD 14— SEE SKY PLAI�IE e �' CUTCHOGUE, N.Y. D 3 m 4 � 15 RIGHT SIDE k YARD o O�u o 2:856.16' NEW RESIDENCE \ PROPOSED " g, ,• ' 5 /i 50 `\ ` l�0��Oj / �<v� 2 STORY ss., \ ,-\ r�o - FRAME \\ I 1 O t;;, DWELLING \ I I ARCHITECTURAL SEAL: ARCHITECT OF RECORD: LEFT SIDE DAVID CHAGNON, ARCHITECTURAL YARD I `RED ARC DESIGN PLLC ^O ,' \� / C/ E-MAIL: ZONE X ' _ / / 31;y., co �\5 P�RI C K�, �/jam DC FILING@DCARCH-NY.COM '7 s tow y 0,27 CHANCE ANNUA/. FLOOD 1 �� '0R ;�' 5// / / I-_, 124.30' / 8'O" 2STp0oOS i O r � ,a \ S @KY PLANE/ RY Fp 77.52' 1A / GZ 4.n :-A DC LAND/N/F of WICI�HAM & * 0 COUNTY,OF SUFFOLK 6 VACANTi 150'+ (j) `� \ / o p AGRIgULTURAL 9T 042839 �0 / I y S 700.1 12IN Cr / < O r /l "ALTERATION OF THIS DOCUMENT 0 EXCEPT BY A ENSED ,' PROFESSIONAL S(ILLEGAL- O GO LAND N/F OF HEPNER & HENDERSON / / I \ I / ,' REAR YARD I1 ,/ --' �FL� 0y200g VACANT 100' G \ / PS ZONE At-(Et. 6) / 7/ \ 7 79,664.86 �Q.FT, or 1.83 ACRES LO ZONE X F \6,STOCKADE FENCE, /� ( // 0.2% CHANCE ANNUAL FLOOD fI ZONE X 11 1 /. ! _! I / 1 \ -1 Pik /� 0.2% CHANCE ANNUAL �IAOD '" DOB EMPLOYEE STAMPS AND SIGNATURES * �0 ZONE AE(FL 6) i 6 LAND N/F OF WELL JOHN RAY Bl I MAUREEN RAY i ( THOMAS JAMESE3, RAY JR i � ``F,, i1\\ \\\'--S \^\ —// ON DWELLING W/WELL WATER F — \ b F 5----._ ----- \ Lo y PIPE \� \\ \ FENCE � I N 87°02'30"W WOOD RAIL FE ' \ \ / TIMBER CC RJCC g ®WELLA710N 239.82' SHEET TITLE I-AND N/F OF JOHN HAAS ELEV. 7.0 DWELLING W/PUBLIC WATER — — — OL DR BROWN FLOOR AREA 5REAKIDOWN: FRESHWATER WETLAND BOUNDARY SANDY LOAM 1-1' CELLAR FLOOR AREA- 1,389 S.F.FINISHED SPACE (236 S.F. UNFINISHED-AS DELINIATED BY EN-CONSULTANTS UTILITY ROOM) � OCT. 6, 2005 � BROWN SM LOAMY SAND FIRST FLOOR FLOOR AREA- 3,4m6 S.F. CNICLUDES GARAGE SINCE ITS SIP T E 1�j L A' N \ 1=8 CONDITIONED SPACE) PALE SW BROWN SECOND FLOOR AREA- 2,993 5,F. (DOES NOT INCLUDE BALCONIES) MEDIUM LOT COVERAGE: � SAND 6_0' 3,406 S.F. HOME/ 19,665 5F. = .04 WATER IN WATER EL 1.0 LOT COVERAGE = 4% PALE HIGHEST EXPECTED 2.0 PROP05EP PECK: \ SW MEDIUM 15T FLOOR WRAP AROUND DECK : 3,048. S.F.� DOB NOW PROJECT NUMBER' SAND 2ND FLOOR REAR DECK : 566 5F. S 1 TE FL AN BSCAN DEC. 28. 2021 13 SCALE: 1/32" = V-01I K. WOYCHUK LS ZONED R-40 AREA:79,664.86 SOFT. Or 1.83 ACRES DRAWING No. SHEET No. aft 5= 1 11 OF 16 45" O.C. MAX 6" MIN. L. 1211 MAX. INV _... 2(o'-m" 15'-gl' 1m'-311 25'-(o TYPICAL TYPICAL SPACING CORNERS z X 24'-0' 2 6 4'-311 12' 9'-3" 121' 9'-311 6'-0" 9'-311 12° Q 10 D F 3,,: #:Y >.> ,�",'" ".'"'+ -` <•,.— , •< —s ,:, O ARCHITECT OF RECORD: �`': ; k• �;';•.•;r i . Y ,',-i; "`'� ,, ,,.;' ti+�,.., '•.• D•AVID CHAGNON,ARCHITECTURAL DESIGN PLLC ' ` : }�.•+• +rll�! •}•I•,.i. .�••::• �. ~v ..% 't'• • �• •; it,r•1 !S. ` :i.0', :`}':'°':• ' jd.� , •�./•,.>.il1r,�.+ +:t. .,t .,/:,• •�'t••i.�,.•�.Y s.i1`:I�r`di�' �•';:. '� 1w1,:•if'•'{;• 1.r.,:a. ,:a,:••V,.N.. ytrv"•••: '.,a5,�'•. y,.•;<`,t•• <J•....:,y �,:Y1r'::c...r ',+t i•',:�•.•....< aa• �::i>«•:f Lt)/`...J:i..'1'.h L. .dt• • ,F,.. 3 WASHERS < E-MAIL: DC_FILING@DCARCH-NY.COM • �..` •`•}•i A END NUT SETUP "ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL IS ILLEGAL" y+ A-7 A.CA SILL PLATE }k :r 3' ,,+ • ; . PROVIDE HOLD DOWNS AT ALL µ} I ;p:`.' — — — — — — — — -- r•,.'''..••,.•. �. _ CORNERS AND BOTH SIDES OF r �, N OPENINGS 6' OR GREATER IN WIDTH. 5/TYPICIAALANGNOR BOLTS t� w ,aAw• ;t•y�:: �',-�.�'i:" „t.. .r.••�a :.d. `:t:•: .,.�.st .'.•.� •!' .r,'. .. .••;'. .., j' '''•:.y e W a•:F `V FOUND'N WALL - • �, - -: P.C. .- =< ^/j ~f s I r �- I -- — — `'• MR Y-O"BELOW I `" `" M' ;•� NOTIFY ARCHITECT /DESIGN L.� •: ( PROFESSIONAL IMMEDIATELY OF ANY CREATE!DESIGN/BUILD GROUP Yam'> j{}:' , , .••,. ,Y. . .;: •;r..i, .;'+:,,. I I •J;•! DISCREPANCIES WITH THE LOCATION 0` 1 I ;'yr�. a�'%•:'•"'• i••:•�•`•'y'••�•'!!,`«. •+"'''•n: I OF ALL PREDETERMINED POINT Typ. Anchor Bolt Dtl. F�RCHITECTURE-ENGINEERING-CONSTRUCTION E.-MAIL:MMUNOZ@CREATEDESIGNBUILDGROUP.COM a r y t •7, LOADS AND NOT TO SCALE TEL:631-464-6668 •'F I ' � •�,: — — — -- .�:. I I `•,•: PROVIDE CONTINUOUS 3-� 14' 2 W�IDsi=J St :`:`.: STRUCTURAL SUPPORT DOWN TO • FOUNDATION ANY UNFORESEEN PONT< I a ` 2-I6D COhp'10N 'SIMPSON' STWD14RJ ��� ( PROPOSES I .,4+ LOADS ARE to BE BROUGHT to THE I NAILS b"O.C. ATTENTION OF THE ARCHITECT OF ro I ''" I O OS �. CRAWL i�C:ORD. '.;: - .. PROP. CRAWL SPACE I• : � ,9 UTILITY I SPACE PROPOSED I j N N >.;:d� GARAGE SLAB ,•' OOi"i � NEW 2" POURED ,�,,•.� NEW 2" POURED(�- BLOGCNG •ENDWALL t /� �CONCR1=tE '. I CONCRETE I ':; ALL DUCT WORK IN UNC�IDItIONEO *' J �Y I ,A�O� I '�•� CONTRACTOR TO PROVIDE A ` • .<, SCREEDICOAT WITH 4 I •�'�' $CREEDC:OAt WITH 4 ''`'�� I SPACES TO BE INSULATED TO CODE, •'; .• `• . 5Y HVAC CONTRACTOR J.` j . NAVIEN TANKLESS WATER HEATER MIL.GLASS I,P.YG. r ' I MIL,CLAS$ I,P.YC. \ AND HYDRONIC AIR HANDLER VAPOR BARRIER STEEL COLUMN VAPOR BARRIER-.__) t CONTRACTOR !� a,-AA NEW 4 THICK P.C.SLAB ( / ( -_ ' ' I RAC OR TO PROVIDE PROPER ,� �� „ ONE 4 MBAR BECKY SHEA DESIGN •:: 'F W/6Xb h0 WELDED WIRE MESH LAPPED ?4 /� FOR FORCED AIR HEALING. ` : :;y / },. I FROM ABOVE. ( :`,; INTERIOR AIR SEALING WITH CAULKING, �. i`�� ,'�' `� BECKY@BECKYSHEA.COM 3ti MIN.OF ONE FULL MESH t WIRED �.. / •l / -+; FRIOR t0 INSTALLING INSULATING AND �, • '• : ' t�% et HATCHED AREA DENOTES SHEETROCK ON ALL EXTERIOR WALLS. } r I TOGETHER®48"OC OVER 6"THICK I 4 ` • ;. BASE COURSE CONSISTING OF CLEAN ° ' I DROPPED CEILING HEIGHT I 3a4 ttD�• ��t` REVISION DATE DESCRIPTION SAND,GRAVEL,OR CRUSHED STONE. I DUE TO SUNKEN -L #1 R` I F FROM A 24.24 P.E. COMMENTS Hold-Down ,. I '. i• I 4., !,: ''i• i '• •'.•.• 7, , •.,. ..•. t,"r ��''''�' 1:••E}'•.'M;V•� ,l.. t, N (K1 Connection Detail NOTIFY ARCHITECT/DESIGN NOT TO SCALE, LOCATE AT EACH DPROFESSSIONAL IMMEDIATELY ANY BUILDING CORNER 1• l. , ;;;. CONSTRUCTION ADMINISTRATION BY: y1.}: >•�:y .. ., • ;,,, „• .�.•<•:+,..: .t•a•`• •a .,.,.. ) _ LOCATIONS OF EXISTING I I I I I I 1 .?�..:1.l,'Y.:r.i•YM:•'`j, a• t•:+'>i•;�' �'+ �•. .i,•}i'•:'•,. ,.�,:.vx;••,,:• ..a.•',;, ...::::. .r,+ •.,• a•x.�.: I 1 I I I 1 I FOUNDATIONS GI •.11 .;, .,,y 4:^,.Y'r,?.�S;:�;�Y.t�,.w•a.fa:'v, �..::• � "•G•�' '.''r;:,o+''•i'} �:�'�• ,,,...�• ';•.F: ,..}.`q.;`. •.r=. •' ..w.:.�'. i 1 I 1 I I I 1 RDERS,COLUMNS, ' �• TO BE DETERMINED POSTS,HEADERS,FRAMING SIZE AND l2)CONTINUOUS 04 REBAR +': s' �ii•':r�' ".1., s+YY•.'�.,.,'• �'�,r ;:i :'.'q'.<xe:"•�'•:'•ia'''>'!C'`�'`:•�'�T `.;i..�s, '7.'•.r... ,�:,r.�..' 1+i. , .. . — -- _ .3-1/211 X 14" BCI 90 2.0 WOOD I-JOISTS 1�,.�? ABOVE WINDOW CLIENT: DATE: SCALE: . • DIRECTIONS 24'-611 51.611 42'-8" _.._.._ __. :..., ALONZO FAMILY 12/24/22 AS SHOWN 40 32'-m" •�i• „ „ 161_gll � :.• CRAWL CLIENT/ADDRESS/SCOPE OFWORK 3-1/2 X 14 BCI 90 2.0 WOOD I-JOISTS J _ ACCESS SECTION 4(a NEW 24" X 24" WINE II ' E R S UNDEiz-i=�OOR-SPACE COLUMNS AT EACH END of 12" NEW BAR COUNTER - ±- R4062 OPENINGS FOR UNDER-FLOOR VENTILIATION :" .} ll)6'-0" LONG 114 REBAR EACH PRI VA i E �► .' BOTTOM CORNER OF ACCESS `� ( PROPOSEC� THE MINIMUM NET AREA of VENTILATION oPENINGs SHALL BE NOT LESS THAN 1 SQUARE FOOT(ODDS h11)FOR EACH 150 SQUARE FEET(14 M2)OF RESIDENCE UNDER-FLOOR AREA ONE VENTILATION OPENING SHALL BE WITHIN 3 FEETI -I-I-IEA-I-�R M I Crawl Space Access (915 MM)OF EACH COINER OF THE BUILDING.VENTILATION OPENINGS SOP- x ALL BE COVERED FOR THEIR HEIGHT AND WIDTH WITH ANY OF THE FOLLOWING MATERIALS PROVIDED THAT THE LEAST DIMENSION OF THE I ; � AREAI NOT TO SCALE • COVERING SHALL NOT EXCEED 1/4 NCH(6.4 MMh CEDARS ROAD I. PERFORATED SHEET METAL PLATES NOT LESS THAN 0.010 INCH(1.8 MM)THICK ". _ : ' STEEL GIRDER C U TC H O G U E, N.Y. 2. EXPANDED SHEET METAL PLATES NOT LESS THAN 0.041 INCH(12 MM) - 0 ..' ::' ;r; "';: �;: •"' "•: �• ,' '�,� :; �' y "a �, (3 THICK I °. �; •.:"— 'EE CONSTR PLAN) •• It,IFILL STEEL FLANGE W/2X 3. CAST-IRON GRILL OR GRATING. m •' ` BASE CABINETS NEW 2411 X 2411 X Milt ( -? ACQ LUMBER 4. EXTRUDED LOAD-BEARINCx BRICK VENTS. ONLY.WALL DEEP POURED :'• -1 ' 'n r- ( CABINETS NOT CONCRETE FOOTING 11 II R M I TOP OF BEAM NEW RESIDENCE N •, + 2 X Ib TWEE WALL,36 TALL, ; �, " 5. HARDWARE CLOTH OF 0-035 INCH(009 MM)WIRE OR HEAVIER I :r.- : PERMITTED. BELOW STEEL COLUMN STEEL COLUMN FROM ABOVE. WITH BUTT JOINT TEMPERED I ( � � � OBE +/- 1/2 b. CORROSION-RESISTANT WIRE MESH,WITH THE LEAST DIMENSION BEING ;`r.;:. 3-I/2" X 14" VERSA-LAM GLASS PANELS TO I I°LOOK MIN BELOW 1/8 INCH(32 MM)THICK a: UNDERSIDE OF CEILING. � J01STS� FLOOR ARCHITECTURAL SEAL: ARCHITECT OF RECORD: �i' __ ____ Lvl. 21 E 3100 HEADER ';.. b' ,.''' I // TOP OF R408A ACCESS ----------------- --- •�'• a I y• JOISTS. DAVID HA , .. ON, ARCHITECTURAL a I BRED ARc E-MAIL: DC` '• t ,• • DC FILING@DCARCH•NY.COM ACCESS SHALL BE PROVIDED t0 ALL UNDER-FLOOR SPACES.ACCESS OPENINGS THROUGH THE FLOOR SHALL BE A MINIMUM OF 18 INCHES BY 24 I .''' :: >: I . 1C INCHES(451 MM BY 610 MM).OPENINGS tHROIKsN A PERIMETER WALLIPA :i;• I 5 CR k ��>' 4 + PROP. CRAUJL SHALL BE NOT LESS THAN 16 INCHES BY 24 INCHES(401 MM BY 610 MM). ( • - 'ti + r' I SPACE- I C2 q `n f WHERE ANY PORTION OF THE THROUGH-WALL ACCESS IS BELOW GRADE,AN C'�-NEW 2" POURED •';: TECO FLOOR JOISTS TO 2X AREAWAY NOT LESS THAN 16 INCHES BY 24 INCHES(401 MM BY 610 MM) e;�:T ��- � a: CONCRETE r• I .0 co WEB STIFFENERS. SHALL BE PROVIDED.THE BOTTOM OF THE AREAWAY SHALL BE BELOW I SCREEDCOAt WITH 4 I '' -DRILL WEB FOR 1/2'DIA. THE THRESHOLD OF THE ACCESS OPENING.THROUGH WALL ACCESS :� BAT+-I I ,I �' OPENINGS SHALL NOT BE LOCATED UNDER A DOOR TO THE RESIDENCE. ':;J ::,. MIL,CLASS 1,P.YG. :`•;: DOLTS •24 O.C_SECURE TOP OF .a I ... PROPOSED :r; I VAPOR BARRIER I •. COLUMNS W/5/8"x DIA.BOLTS. �T 42833 y0 _� RECREATION I NEW STEEL COLUMNS AT BOTH ENDS 0 F N E�'•� � "ALTERATION OF THIS DOCUMENT �y p/� 1',' '...IL' EXCEPT BY A LICENSED C'F BEA I.POST DOWN COLUMNS PROFESSIONALISILLEGAL' SOLID TO STRUCTURE BELOW.NO all " X 3'-0" GUST WOOD SQUASH BLOCKS PERMITTED. 40 r: s L Steel Girder Detail w1, y — — — — — — •• NOT TO SCALE % ;. ..�.. z., - ._... , a F• _ :p• ra'•.:w... :i, .♦ .'a.+^ti. •r� I +ti' •' ..R.•:, �..•,+�; ',' Y, ••.;+ t,• N Alt iv ;;k ,:,<.:; DOB EMPLOYEE STAMPS AND SIGNATURES �. .;: NEWS WI WALL BELOW — —.•— — a-'''.:-:_ — :. .-- — H DE F'ND. WA r p•: CONTRACTOR TO PROVIDE FLOOR HATCH CONSTRUCTED • OF COMPOSITE DEC:KNG TO PLACE OVER WINDOW WELL IPE COLUMNS. COORDINATE WITH �n %. 6'-011 6'-4" 5'-I(d11 23'-8" = AND CREATE A SEAMLESS TRANSITION FROM HATCH TO DECK INSTALLATION. i1, I — SURROUNDING DECKING.THIS FLOOR HATCH IS TO BE 12" 18'-m" 12" 24'-6" p <, :' i 12„ INSTALLED N LIEU OF GUARDS. 77777, 43'-311 L—— —_• ,J `7te ed Footi n Dtl. _ SCALE • 1/2" = 1'-0" A� CE.L L,4 R FLOOR FLAN�l FFOOLNDATIW all IOONRWALL ON 166' ((WIDE) � SCALE: 1/411 1'-011 CONCRETE FOOTING WITH CONTINUOUS POURED TYPICAL CONTINUOUS 5 REINFORCING EXTERIOR WALL BARS IN FOOTING(3"COVER 1/2" THICK PRE-MOLDED TOP OF DECK SHEET TITLE MIN)36"MIN. BATT. EXPANSION FILLER DEPTH BELOW GRADE. INSULATION 1111 4"POURED CONCRETE NEW 3"DRAIN TO 24"0 X 2411 SLAB OVER W6 5111 5 11 211X AC�Q DEEP PREFAB DRYWELL POLYETHYLENE VAPOR NOTE: 2 RIM JOIST. NUMBER OF RISERS TO 1 CELLARFLOOR AND GRAVEL BED (2)211X6"ACQ BARRIER SELECTED EXTERIOR BE VER OF IS FIELD. SHOE PL. SIDING(SEE ELEVATIONS). INSTALL NEW OCXI4 CASEMENT �� • xx • , , .. •' .. , d WINDOW MAX 4411 ABOVE FN.FLR TYPICAL 1• LAP BUILDING PAPER i I")CS" RISER (3)12"LONG CONCRETE ANCHOR BOLT OVER DECK FLASHING 5/4 X b DECKING +r --�� PLAN ANCHORS 05 REBARS a 12"O.C. �. VERTICALLY)TO TIE NEW u ' . 'n . INSTALL ALUMINUM DECK 1 ) A C�Q FLOOR FOUNDATION TO EXISTING U31NG .• 2"X24"(R-10)RIGID FLASHING OVER NAILER JOISTS INSULATION AT ALL \ (SEE PLAN). NON-SHRINK GROUT(TYPICAL) • EXTERIOR WALLS. 5� NEW 12" WIDE FIXED LADDER Z - a• w „ d5 \¢ A. } ° FINISH GRADE. NEW EGRESS WINDOW WELL = : ,,.-T 1211 THICK POURED CONIC. (1"*K' DOB NOW PROJECT NUMBER TOTAL AREA S SQ.FT.MINIMUM m ` !„ ',.�; ;: FOUNDATION WALL. INSTALL ICE t WATER ` ••: a • :. ,: . '• "' SHIELD OVER PLYWOOD O • t''� JT� BSCAN •:• SHEATHING TO APPROX. • ;`_�-: ,;� •_ �' l3)�5 8"-12"ABOVE DECKING -- -- "- a REBARS :•• , :. NOTE: 0 •' ;' • . CONNC.PAD UNDER CONCRETE to BE STAIR STRINGER M4. 21-0,11 3,500 PSI MIN. Typ. Fnd. Wall Detail �� Porch Flashing Detail Typical Deck Stair DRAWING No. SHEET No. 111111W3 NOT TO SCALE 3"NOT I'-011 SCALE : 1/211 OF 16 Li D L 6 CM N ARCHITECT OF RECORD: D.AVID CHAGNON,ARCHITECTURAL DESIGN PLLC E-MAIL: DC_FILING@DCARCH-NY.COM "ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL IS ILLEGAL" 14'-0" 13'-711 — 1 — 2'-8" 12'-10" 2'-0" L. 10'-61I _ DECK STEPS ABOVE _ DECK STEPS ABOVE NEW BEAM.SEE PLAN. LINE OF RESIDENCE C — — ' — --(3)SD COMMON NAILS At � "' (2)2" x 10" DECK RIM JOIST b (2)2" x 10" DE:CK RIM JOIST I i� EACH END OF STRAP. N (V CREATE! DESIGN/BUILD GROUP - I ARCHITECTURE-ENGINEERING-CONSTRUCTION I -WRAP CS20 STRAP CONTINUOUS E.-MAIL:MMUNOZ@CREATEDESIGNBUILDGROUP.COM PROPOSED RESIDENCE FROM POURED CONCRETE PIER TEL:631-464-6668 " x 10" SSU t A I I ( OVER ROOF BEAM AS SHOWN. i PECK OOR J015T5 0 6 O G. Td I � -NEW 6"X 6"ACQ POST.WRAP - B i, I WITH 5/4" TRIM BOARDS OVER LU 2 x 10 CK FL JOISTS ( �p CONTINUOUS STRAPPING. `q[~ illII LU ® 6' O.G. EMBED STRAPPING 6" INTO Ql ° I CONCRETE.SET WITH EPDXY C4 I tu MORTAR"PRIME GEL 2500 QUICK X I I I ° BOND"OR EQUIVALENT. L114 I SELECTED DECKING. BECKY SHEA DESIGN BECKY@BECKYSHEA.COM Ea X I 9--DECK JOISTS(SEE PLAN). REVISION DATE DESCRIPTION C*° Q II I #1 10.24.24 P.E. COMMENTS .- NEW POURED CONCRETE FOOTING. I I I ( SEE FOUNDATION PLAN. o I Column to Beam N� PROPOSED RESIDENCE X C, Connection CONSTRUCTION ADMINISTRATION BY: 0, � Not t0 SCALE TO BE DETERMINED I � II I CLIENT: DATE: SCALE: LINE OF FESIDENCE � I ALONZO FAMILY 12/24/22 AS SHM"Ill - 0 1L [I� 141 I( I (� 1�1-011 CLIENT/ADDRESS/SCOPE OF WORK IV ATE DECK STEPS ABOVE -- M I s1p X� _ _ NEW 24" X 32" POURED — RE I Em C E >( ; CONCRETE FOOLING BELOW (� (2)2" x 10" DECK RIM JOIST I�Q R II COLUMNS ABOVE.FOOTING IS �1 TO BE A MIN.OF 36 BELOW I I 2" OlCKI COCEE1OR O CONCRETE POURED A MIN. CEDARS ROAD 0 16" O.G. OF 3500 PSI (tYP).SEE �•�•?: I ? I ;e;,•:N, DETAIL II III ON THIS SHEET. I C U TC H O G U E, N.Y. LU (IDLINE OF RESIDENCE (2)2" x 10" DECK RIM JOIST X I �� NEW RESIDENCE $ � ADDALTERNATE EN II �°(r II PROPOSED RESIDENCE 2" x 10" �CK FLOOR JOISTS ^8 I CONTRACTOR t0 PROVIDE AN ALTERNATE PRICE TO Ilu Q I INSTALL A NEW WRAP AROUND PORCH AND 8 O� ° Lu a CORRESPONDING STEPS IN POURED CONCRETE IN 2" x 10" DECK FLOOR JOISTS I ARCHITECTURAL SEAL: ARCHITECT OF RECORD: fN- LIEU OF WOOD.CONCRETE PORCH 6 TO MATCH THE I A O.C. 0�� I A DAVIHI EC URAL co I I O DIMENSIONS PROPOSED FOR THE WOOD PORCH. _ I _ BRED ARC DESIGN PLLC LY E-MAIL: INCLUDE THE FOLLOWING: '� y DC FILING@DCARCH.NY.COM e I - PROVIDE CONTROL JOINTS WITH A GROOVER I I I I 0�5 P\R1 C k, C I X THROUGHOUT THE INSTALLED AREA. 4 ~ N I 21_011 (" jr O ,r tv Q ALL SURFACES TO BE FINISHED SMOOTH WITH A I I BULL FLOAT. * to- - FOOTINGS TO BE A MIN.OF 36" BELOW GRADE. I r. .... - INSERT 12" LENGTHS OF REBAR 8 INCHES INTO THE L1 Q s `'' ' 9 O¢ FOOTINGS.THE TOP OF THE REBAR IS TO BE 2 �42II3� .. v I I I INCHES LOWER THAN THE FINISHED HEIGHT OF THE n m p -•I •• I • EXCEPT BY A LICENSED TU-I STEPS. I I (r I I r:•,:.:. O N "ALTERATION OF THIS DOCUMENT } - PROVIDE GRID REINFORCEMENT FOR LANDING. -� X L1(P `.`Lr,`.;�.4(. 6] PROFESSIONAL IS ILLEGAL" 6T I N cn •kw :. PROPOSED RESIDENCE I I PROPOSED RESIDENCE ' `'• — PRESSURE TREATED �� ,:: ;. 0 LOW DECK BEAM (2)2" x 10" DECK RIM JOIST LINE OF RESIDENCE LINE OF RESIDENCE _—_ _ ° " DOB EMPLOYEE STAMPS AND SIGNATURES 211 X 10" LYL LEDGER BOARD FOR PROPOSED RESIDENCE- — — — l3)2" X 12" _ ". ,: `: ,�;: 2 R X 10" LYL LEDGER BOARD FOR :,`•.:• ' •- .' ' JOISTS ATTACHMENT / � `', ;;. ;:�;':.�;•. t:....: •..ti.� f JOISTS ATTACHMENT PRESSURE TREATED ' LOW DECK BEAM C14 — — LINE OF RESIDENCE _ — , ,• I I I II 11 N 2" X 10" LYL LEDGER BOARGI FOR 112 -9 I i JOISTS ATTACHMENT � W MOW N I I M WELL O I II'-611 E L `L p O 1'-0" O CONTRACTOR TO PROVIDE A 6 � 4-411 LU POURED CONCRETE FOOTING I L1 0 C k I BELOW PROPOSED OUTDOOR --t:I I NEW 8" WIDE FND. WALL BELOW IPE 0p V 0 II ( KITCHEN BASE COUNTER TOP x I COLUMNS TO BE A MIN. OF 36" 0 OF FOOLING t0 ALIGN WITH I LOP OF DECKING.CIA ( BELOW GRADE. PROVIDE 8" TALL x e - I X 16" WIDE FOUNDATION. SEE FND. N _x = 11711 PLAN FOR DIMENSIONS. SET TOP I SHEET TITLE I I OF FND.WALL BELOW DECK JOISTS. lei EXTERIOR WALL Tn DECK STEPS ABOVE DECK STEPS ABOVE DECK STEPS ABOVE DECK STEPS ABOVE SECURE NAILER W/3/8"0 X 3-1/2" D"CK LCNG LAG BOLTS W1 WASHER 0 F 2'-0" 8'-6" 8'-6" 8'-6" 8'-C' 8'-6" 8'-6" 8'-6" 2'-0" 12"DL�Cs INTAGGERE TOP 4 BOTTOM O SOLID RIM JOIST . _ ®U ® TI M 80'-4" 2"X 10"ACQ NAILER RIM JOIST P LA N . CE_�ILAR FLOOR FLAN SCALE: 114" = 1'-011 DCIB NOW PROJECT NUMBER JOIST HANGER BSCAN FOUNDW WALL. 2 Detail of Joist Attachment _ SCALE : 1/2" o 11-011 DRAWING No. SHEET No. ow gift as ® 4 OF 16 105'-(o" 41'-9" 35'-3" 28'-(o 25'-0" 15'-3" 9'-3" 25'-6" 28'-0"01 4'-311 0 3'-5" 3'-511 4'-311 -5" II'-fo" ARCHITECT OF RECORD: DAVID CHAGNON,ARCHITECTURAL DESIGN PLLC E-MAIL: DC_FILING@DCARCH-NY.COM � "ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL IS ILLEGAL" -�- ELECTRICAL TO COMPLY ALL PROVIDED ELECTRICAL WITH N1104J NOT LESS THAN WORK IS TO BE INSTALLED IN 15% OF THE LAMPS IN ACCORDANCE WITH THE 2020 PERMANENTLY INSTALLED A NYSBC,THE 2015 LIGHTING FIXTURES SHALL BE INTERNATIONAL RESIDENTIAL HIGH-EFFICIENCY LAMPS A-� /�+c CODE CHAPTER 34 TO 43 /J�J AND THE NATIONAL ELECTRIC CODE NEC)/NFPA 10. Multiple L.V.L. -----1211 ROOF OVERHANG ® Nailing Schedule CREATE!DESIGN/BUILD GROUP I ARCHITECTURE-ENGINEERING-CONSTRUCTION R „ E-MAIL:MMUNOZ@CREATEDESIGNBUILDGROUP.COM " • MIN 2 ROWS OF 16D (3 1/2„)NAILS At 12 O.C. I 3-1/211 X 1411 VERSA-LAM I TEL:631-464-6668 KLAR I 3'-0' WIDE X 8'-0" TALL LVL 2.1 E 31 a RIM JOIST •FOR 14",IV' AND 18" BEAMS MIN.OF 3 ROWS OF DOOR PROP I 160 (3 1/1")NAILS At 12" O.C. 3-1/2" X 14" BCI 90 20 WOOD I-JOISTS PROPOSEC> PORCN Stu I N I 4 PORCH UNDERSIDE OF PORCH I PROPOSED CA cLo�0 T. CLADDED WITH --- -------------------------------- 1 I To BE cLAc -- i 3/411 X 3-1/2" PLANKS 6" DIA ------ _ , OF IPE WOOD � � Q - 6' 10 0 i (BRAZILIAN WALNUT). COLUMN LEGEND1 TYSTEEL PE-X 6 D HEARTH STONE t0 BE I I BECKY SHEA DESIGN DRYWALL TO BE NEW WALLS: , -� P / , SEE ELEVATION I I SELECTED.HEARTH TO BE 6" i ;9 BECKY@BECKYSHEA.COM I INSTALLED ON ALL EXTERIOR- 2" X 6" DOUG FIR "2 , E / 1I f FA � WIDE X 16" DEEP X 4" THICK w (BRAZILIAN X 4"I IFE AN WOOD) INTERIOR.WALLS AND OR BETTER INSTALLED 16" O.C. -1 4 cl 0, NEW WOOD BURNING FIRE }� A- REVISION DATE DESCRIPTION GARAGE CEILING. / I S`(ALLED1 .TS C ` / o o PLACE INSTALLED AS PER q DECKING I I INTERIOR_ 2" X 4" pOUCx FIR 02 c� I #1 10.24.24 P.E. COMMENTS OR BETTER INSTALLED 6 16" O.C. ;' � � � � ��� CHAPTER 10 OF THE 2020 �.OP" RESIDENTIAL BUILDING I I ® NEW 4 x 4 OR 4" X 6" WOOD POST O I a0 ��� w CODE OF NEW YORK STATE 3O �x� Ul NEW POST FROM ABOVE U G�OI'� o I I � - 70 '�m I I X CN j II I1L -L� CFM PROPOSED i I I HARD WIRED SMOKE DETECTORS - Q� 6" DIA. Q Fi"'1 Sp INTERCONNECTED SINGLE STATION 61 , STEEL > " LIVING I DEVICE IN ACCORDANCE WITH COLS• ROOM I I CONSTRUCTION ADMINISTRATION BY: STATE CODES 2) X 2 D _- I - - - _- - o o LG.W I; TO BE DETERMINED CA I/ ' > 4" D by!18' -1-"- CLG.Ht. i I cf7 CARBON MONOXIDE DETECTOR //` ' �z I I of / A L 2 tF- 1 I CLIENT: DATE: SCALE: 48 O� � w „ „ ALONZO FAMILY 12/24/22 AS SHOWN Np HEAT DETECTOR � '' CG t. E ENS- s O I q -'�4 2 PRESSUREA , I O Ob E tHWA� , I W q FLOOR OI TS A 16 O.C. I I St LE>� WAL �' o, FOR DECK CONSTRUCTION. � � CLIENT/ADDRESS/SCOPE OF WORK N; 70 NEW '10 C.F.M.MECHANICAL 5- 4" 1 RS -LAM/ CFM EXHAUST FA�1 ( VENTED TO vL 2�31& = r � I OUTSIDE) AS PER (R3033) N 7- X LU 3 DN D I - �+ I I PRIVATE I I SD 61 XIS I DN 'n 5-1/4" X 14" VERSA-LAM 5-1/4" X 14" VERSA-LAM A i N uP i O PROPOSED I I IES ® C E I LVL 2.1E 3100 HEADER LVL 2.1E 3100 HEADER }�A In }�' 3 I I COVERED DECK I i =- % 1 P VOT I I UNDERSIDE OF DECK i i in „ DOOR ; TO BE CLADDED WITH CEDARS ROAD �- - ----___-_- GARAGE DOOR --___12_ROOF__-- GARAGE DOOR _ -- ( m 1 I HATCHED AREA DENOTES AREA OF SUNKEN N " ------ ---- �- -3 WIDE X I 3/4 X 3-1/2 PLANKS 8'-0' WIDDD X 8'-(dr��Ll OVERHANG W-0' JIDE X 8'-0" TALL o FLOOR SEE CROSS SECTION "A" AND CELLAR N - STYLE,MAKE ,AND STYLE,MAKE ,AND I I Q INStALLDO PLAN FOR ADDITIONAL DETAILS. j _� w of IPE WOOD j I CF U TC H O G U E N.Y. q (BRAZILIAN WALNUT). I I MODEL TO BE SELECTED MODEL To BE SELECTED '�3 pr I I Q I I i :oHOMEOWNER. 00 M FLOATING STAIR WITH CENTRAL STRINGER BY BY HOMEOWNER BY � IY. ��1 _ "VIEWRAIL" OR EQUIVALENT. INCLUDE GLASS I I� 1 O PANEL BALUSTERS WITH WOOD HANDRAIL.ALL -�i N (I 3 , I 31 _ X Cq w NEW RESIDENCE X q p }1 QL FINISHES TO BE APPROVED PRIOR t0 ORDERING. 4—!I 11' C N L , `" N >c r `-1 X 4 In WOOD j I CNi I _ Fd IU 22 0 X (BRAZILIAN WALNUT) i I "`-� �n O k PROP- OPEN TO wI ,n DECKING% . ~ q FOYER 3-1/2" X 14" BC1 90 2 0 WOOD I-JOISTS I ( `9 ARCHITECTURAL SEAL: ARCHITECT OF RECORD N N A50V� �� I I ' DAVIDCHAGNON, UNDERSIDE OF j I '9 ,(,GR`-D ARC DESIGARCHITECTURAL PORCH ROOF TO 11 I I 5� ,` y� E-MAIL: N PLLC BE CLADDED N o �--� `r u I Q \ R1 C�\ e DC_FILING®DCARCH•NY.COM „ „ - p 6 DIA.STEEL COLUMN At EACH END OF NEW , �� P WITH 3/4 X 3-1/2 X LL O CH X BEAM (TYP.)TO BE INSTALLED OVER CONTINUOUS I 10 0 PROPOSED w 30 ® Q rh !` v n� PLANKS OF IPE I I N ter'- STEEL BELOW AND OVER NEW FOUNDATION WALL. I =r CLG.Ht. , ' ;;? . ? IN INc� ROOM WOOD (BRAZILIAN I I I NO WOOD SQUASH BLOCKS PERMITTED. I X V WALNUT). in I = 0 4 5-1/4" X 14" VERSA-LAM LVL 2.1 E 3100 * ! 0 II ,I o ltl OVERALL KITCHEN LAYOUT O r ;1 Z' O DASHED LINE REPRESENTS ,I I I b x 8 -� IS SHOWN FOR PRICING CONTINUOUS SPAN HEADER OVER N to �• 8 O DU LINE OF WALL ABOVE O 8 I POST m u PLUMBING SLIDING DOOR AND SIDELITE°>. •� aa283g pQ- 0 PURPOSES AND PL --- _--- 0 ui 1 FIXTURE COUNT.FINAL In NEW +/- 26' W14 X 30 g I DESIGN t0 BE PROVIDED F NE`N 'ALTERATION OF THIS DOCUMENT CA jn STEEL 1-BEAM TO 6 6 PROFESSIONAL IS ILLEGAL' I `` ( ���u LWORKER AND I---- BY MIL EXCEPT BYALICENSED SUPPORT BATHROOM - -------- ------------- •� 00 � ND APPROVED BY HOMEOWNER � 0 p� CANTILEVER ABOVE. O (2)36" X 96" 2 — POCKET DOORS COUNTERTOPS TO BE SELECTED [Q O - _ t9 c r• NEW V-20',W14 X 3 I +- z� BY HOMEOWNER SLAB t0 BE � `"LU r I I rN m DK ---STEEL-I-BEAM-TO--] �y�- �°� i q II APPROVED BY HOMEOWNER AND � �� SUPPORT BATHROOM SD �,, :-`tip`_.-` i DESIGNER PRIOR TO PURCHASING. �n w O OS IY w �' CANTILEVER ABOVE. ; -_-_- -1 =i) I Ul PROPOSED DATHROOM -4 ARE - N z ' a - o PROPOSED a ; I ` 11 --I-- x q X (o I --T---------------T-- - 1161`- AO E � � 1� i I, I WINE 1 10'-01, I - RQOM /'' F 1 �i -( I INSTALL FIRDGE I 0 1m1-0" DOB EMPLOYEE STAMPS AND SIGNATURES ,�, mI-�n, CONTRACTOR TO µ^...1�, �'" �- .-_-= --1-- ACOUSTIC I I L- 1 , ® Cl Q INSTALL ACOUSTIC ! I INSULATION AT —T-- r----��- - CLG.WT. =1 1 X u! �•q g f 'CLG.I T. I 1 I I I1 X I- _ INSULATION ABOVE I ALL WALL w _ r, cn C` �"�-,+ I I TRASH 1 SINK 1 D/W UNDERSIDE CN= z ut / PROPOSED GYM. v , - ! __i-- SURROUNDIt•K� 1 I 1 11 I , iw _.__ ._____ �---ss QT BATHRM.TO BE Lfl—1 I ' _ L.J �� �� U7 I. ` J 1 3-1/2 X 14 BCI 90 2.0 WOOD I-JOISTS 1 "1X 14" CI 90 20 WOOD I-J(CJISTS I EQUAL 10'-01, EQUAL CLADDED WITH I I 1O.G. 3/4" X 3-1/2" .t g n I --1-- - �+ PLANKS OF IPE , _ _ i II 5-1/4" X 14" VERSA-LAM LVL 2.1E 3100 WOOD (BRAZILIAN I NEW +/ 26,W14 X 30 STEEL I-BEAM t0 -. 1 PROPOSED KITCHEN CONTINUOUS SPAN HEADER OVI:R 1� WALNUT). SUPPORT BATHROOM CANTILEVER ABOVE. l 4' --i-- SLIDING DOOR AND SIDELITE:S. `V 01 I I I I ® O N 0 UNDERSIDE OF PORCH I I I 1 1 l O X m ROOF TO BE CLADDED -_ - WITH 31. X 3-1/2" — +- ��{- d? � SHEET TITLE KEYNOTES PLANK., OF IPE WOOD J PROP. (BRAZILIAN WALNUT). 11 q e RANGE HOOD TO WINDOW NOTE- INTENTIONALLY INTENTIONALLY LEFT EMPTY. 3-1/211 X 1411 BCI 9O 2.0 WOOD I-JOISTS a BE PROVIDED WELL DOUBLE UP ALL FRAMING UNDER EXPOSED 6 UJ ABOVE RANGE NEW PARALLEL PARTITIONS AND 3" x 8" IPE n-�- _ - AND VENTED TO NEW WOOD POSTS. OSHELVING SYSTEM FOR CLOSET STORACxE TO BE COLUMNS �B - D - - N ' - - - -- -— `x" THE EXTERIOR FIRST FLOOR EQUALLY l2J 3-I/2 X 14 BCI 90 2fd ZP X 4" IPE WOOD 4-4 1 X 4 IPE WOOD UNDER ALL WWOOD P S SSELECTED AND/Old DESIGNEDD. (8)TOTAL XWOOD I-JOIST �� �� SPACED W/+/-8" (BRAZILIAN WALNUT) PROVIDE NEW STAIRS DOWN TO NEW BASEMENT AND UP OF DAYLIGHT (BRAZILIAN WALNUT) OTO NEW SECOND FLOOR AS REQUIRED. DOUBLE UP ALL BETWEEN JOISTS A iD DECKING PROPOSED DECKING. PROVIDE AD BLO('.KING19 FRAMING AROUND STAIR AND PROVIDE JOIST HANCsERS �/ UNDER LOAD BEARING WALLS LA tO CREATE A q_7 PORCH * ALL CONNECTIONS. MINIMUM 6'-8" HEAD HEIGHT. LOUVER Zv X 4" IPE WOOD PROVIDE 36" HIGH HANDRAIL WITH SPINDLES SPACED ASSEMBLY. (BRAZILIAN WALNUT) MAXIMUM 4" APART TO CODE.STAIRS ARE TO BE DECKING. "FLOATING"STYLE MANUFACTURED BY VIEWRAIL STAIRS f OR EQUIVALENT.STAIRS ARE DESIGNED WITH A CENTRAL STRINGER AND AND NO RISERS. DOB NOW PROJECT NUMBER OCONTRACTOR TO PROVIDE 81" DEEP WALL NICHE FOR RECESSED SHELVING. BSCAN b'-10" 11'-4" (0'-10" 9'-311 9'-311 5'-9" 14'-I" 5'-9" 8'-2" 8'-211 25'-0" (0'-6" 18'-6" 25'-6" 16'-3" 32'-0" 19'-0" 43'-3" Aw —Pi DRAWING No. SHEET No. FIRST FLOOR PLAN _ Oft5 SCALE: 1/4" = I'-0" OF 16 I I J 0 E S CONSMI H"M ARCHITECT OF RECORD: DAVID CHAGNON,ARCHITECTURAL DESIGN PLLC E-MAIL: DC_FILING@DCARCH-NY.COM "ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL IS ILLEGAL" 68 .) EXTERIOR UIINDOW5 AND DOORS 11'-0"01 19'-0" I6'_911 FIRST FLOOR WINDOW ,AND DOOR SCHEDULE 10 CREATE!DESIGN/BUILD GROUP 2'-6" 6'-0" 4'-6" 3'-0" 3'-0" 3'-3" 6'-0" 9'-9" I 1'-4" WIDE X 8'-0" TALL KLAR Cl0 FIXED ARCHITECTURE-ENGINEERING-CONSTRUCTION 10 01E-MAIL:MMUNOZ@CREATEDESIGNBUILDGROUP.COM A IA 4'-3" WIDE x 8'-0" TALL KLAR DOOR PIVOT MAIN ENTRY I TEL:631-464-6668 2 1'-0" WIDE X 8'-0" TALL KLAR C10 FIXED A-7 THE BUILDING THERMAL CONTRACTOR TO BRACE WALLS USING ENVELOPE SHALL BE WOOD STRUCTURAL PANELS AND 3 8'-1" WIDE X 8'-0" TALL KLAR VISION SLIDING DOOR ® 0 CONSTRUCTED TO LIMIT AIR CONTINUOUS SHEATHING AS SET FORTH IN LEAKAGE IN ACCORDANCE WITH SECTION 601.1 OF THE INTERNATIONAL 4 3-0 WIDE X 8-0 TALL KLAR C10 FIXEDIVA - r THE REQUIMMENTS OF SECTIONS RESIDENTIAL CODE.PROVIDE NEW LEADER DOWN TO GRADE. NI102.4.1 THRZOUIGH N1102AB 5 6'-9" WIDE x 5'-0" TALL KLAR C10 OPERABLE o UNOBSTRUCTED BRACED WALL PANEL ADJACENT TO WALL OPENINGS FOR THE N — NEW WASTE PIPE INSIDE ROOF ASSEMBLY. 70 LENGTH DENOTED IN PLAN.SEE SHEET A5 5A b'-0" WIDE X 6'-0" TALL KLAR Gl0 FIXED S / D NEW ROOF DRAIN ASSEMBLY(TYPE- „ „ 48" LAY. I A.3-1/2 X 14 BCI 90 2.0 WOOD I-JOISTS - b' FM = liz FOR STRAPPING DETAILS AT ALL BEBECK SHEA DESIGN M SCREEN IN CAST ALUMINUM COVER WITH `; 110 C:ONNECtIONS. 69-3 WIDE x BITUMEN MEMBRANE FLASHING SEALED TO � 13 N CROSS BLOCKING.FILL JOINT WITH A H OOM 04 POLYURETHANE INSULATING FOAM. w _. bA Y-O" WIDE x 8'-O" TALL KLAR DOOR MUDROOM DOOR REVISION DATE DESCRIPTION PROVIDE INSULATING SHEATH FOR STOW I -� DRAIN PIPE INSIDE ROOF DECK AND � __-- __-- ---- LAUNDRY ROOM SHELVING 65 V-O" WIDE x 6'-O" TALL KLAR CIO FIXED #1 10.24.24 P.E. COMMENTS ILISINK AND MILLWORK TO BE u- EXTERIOR WALL.PITCH NEW ROOFING ® i------------- SELECTED BY OWNER bC 3'-0" WIDE x 6'-0" TALL KLAR CIO OPERABLE/EGRESS ASSEMBLY TOWARD DRAIN AS REQUIRED. 0 I 9 � rgOOF OF ROOF PITCH x Lu - DRYEREP TO BE VENTED t0 6 6D 9'-3" WIDE x 1'-3" TALL KLAR CIO FIXED CzAR,4C�sE BELDUI N Room EXTERIOR As PER lRlSml.0 2ND FLOOR WINDOW ,AND pOOR SCHEDULE PROVIDE GALVANIZED METAL DRAIN PAN dF ly ROOFING ASSEMBLY NEW ROOF DECK TO RECEIVE SOLAR an r- O UNDER WASHING MACHINE AND CONNECT w (FROM TOP To BotTa1 PANELS.GENERAL CONTRACTOR t0 WORK 'o TO FLOOR DRAIN AS REQUIRED. ' '1 2'-0" WIDE x 4'-0" TALL KLAR CIO OPERABLE CONSTRUCTION ADMINISTRATION BY: 3-1/1" X 14" BCI F- 20 WOOD I-JOISTS H �� Q EPpM MEMBRANE IN CONCERT WITH SOLAR PANEL INSTALLER _ �-1/2 X 14 BCI 90 2.0 WOOD I-JOISTS w - INSULATION OVERLAY BOARD TO PROVIDE PROVISIONS FOR THE _ _ 6l . , - RIGID INSULATION AL INSULATION INSTALLATION of THE PROPOSED F200F 0 e = ; g�_0�� 0 _ 8 V-O" WIDE X 3'-0" TALL KLAR CIO OPERABLE/TEMPERS TO BE DETERMINED 0 0 - VAPOR BARRIER MOUNTED SOLAR PANELS.ALL ROOF �n t 1 t CLG.HT. �� M O ;n 9 l'-6" WIDE X 6'-0" TALL KLAR CIO FIXED CLIENT: DATE: SCALE: - 3/4"CDX PLYWOOD PENETRATION ARE TO BE SEALED WATER `" `" I� �ACJH.� X iu ALONZC FAMILY 12/24/22 AS SHOWN TIGHT AND ARE t0 BE TESTED FOR LEAKS - I PROPOSED O I I ' `r 10 4'-0" WIDE X 4'-0" TALL KLAR CIO SLIDING DOOR PRIOR TO COMPLETION. -��� I - I SD DRYER "��.l C S ' I I v'D PROPOSED ,n_j 1 X 4 IPE UJOOD CLIENT/ADDRESS/SCOPE OF WORK L lu BEDROOM 4 LO E7�, I b J BEDROOM " 11 5'-0" WIDE X 6'-O" TALL KLAR CIO FIX ED effN ROOF DRAIN ASSEMBLY- ,q� 91_01I ' r, -. 48" X 96" - IBRAZILIAN WALNUT) DECKING. 12 6'-O" WIDE x 4'-0" TALL KLAR CIO OPERABLE SCREEN IN CAST ALUMINUM COVER WITH BITUMEN MEMBRANE �� CLG.HT. "��. " - , '- POCKET DOOR02 �/ '- PRIV TE FLASHING SEALED TO CROSS BLOCKING.FILL JOINT WITH 00 POLYURETHANE INSULATING FOAM.PROVIDE INSULATING ® 0 NI�W �I CONTRACTOR TO 9'-0" 13 3'-0" WIDE X 4'-0" TALL KLAR Cl0 OPERABLE �- SHEATH FOR STORM DRAIN PIPE INSIDE ROOF DECK-� v�^ (2)IS X 96 `' PROVIDE A DBL. CLG.HT. „✓•'' x� PROPOSE I y'I X 6" THICK WALL 70 �� SD �' 14 2'-0" WIDE X 8'-0" TALL KLAR CIO FIXED N 3-I/1" X 14" BCI 90 2O WOOD I-JOISTS 84 �-IALL CONCEAL STRUCTURAL RE I DE i�C E }!P -7 COLUMN AND POCKET = NEW PARAPET.SEE SECTION DRAWING FOR PARAPET �--� DOORS. `. R33012.12 PROTECTION OF OPENINCxS DOO "t ASSEMBLY SPECIFICATIONS. - _' I �ct`� SATH m NEW WASTEE PIPE INSIDE ROOF ASSEMBLY. t I PROPOSED EXTERIOR GLAZING IN BUILDINGS LOCATED IN WINDBC>RIE DEBRIS REGIONS CEDARS ROAD SHALT_BE PROTECTED FROM WINDBORNE DEBRIS.GLAZED OPENING Ill ROOF DRAIN gp �'-4" I Il'-3" BALCONI' `� _ PROTECTION FOR WIND50WE DEBRIS SHALL MEET THE REQUIREMENTS OF THE ROOF PITCH I O b —r— 11 ® LARGE MISSILE TEST OF Al Eli AND Al EIW6 AS MODIFIED IN SECTION C.U TC H O G U E, N.Y. / I WALK-IN 1 62 LAV. PROVIDE WINDOW ABOVE TUB WITH HAZARDOUS - a) 3012.1.2.1.GARAGE DOOR GLAZED OPENING PROTECTION FOR WND5ME / NEW LEADER DOWN t0 GRADE. -I- O I C OS T J ° GLAZING AS PER SECTION R308.4. DEBT'IS SHALL MEET THE REQUIREMENTS OF AN APPROVED IMPACT-RESISTING ® � r STANDARD OR ANSI/DASMA 115. M. F,�rEP710N:WOOD S7RUCTURAI.PANELS WITH A THICKNESS OF N07 LESS THAN NEW RESIDENCE ,n 15 GLASS PANEL BALUSTERS WITH WOOD- _---- 1/16 INCH(11 MM)AND A SPAN OF NOT MORE THAN 8 FEET(2438 MM)SHALL BE ® O I f HANDRAIL.ALL FNISHES t0 BE __ __ PROTECTION.PANELS SHALT_BE PRECUT AND 1st 1—E PEI211ITTED FOR OPENING NEW GLASS RAIL APPROVED PRIOR TO ORDERING. I ATTACHED TO THE FRAMING SURROUNDING THE OPENING CONTAINING THE PROGRAM �� A - ASSEMBLY WITH Ul I 11 Il t MASTER CLOSET SHELVING = PRODUCT WITH THE GLAZED OPENING,PANELS SHALL BE PREDRILLED AS ARCHITECTURAL SEAL: ARCHITECT OF RECORD: ACH �} v I 11 11 3-I/2 X 14 BCI 90 2m WOOD I-JOISTS SYSTEM AND ISLAND MILLWORK x� b-0 X 42 i REQUIRED FOR THE ANCHORAGE METHOD AND SHALL BE SECURED WITH THE DAVID CHAGNON, TALL CENTRAL W I TO BE SELECTED BY OWNER "� 1vD A ARCHITECTURAL ATTACHMENT HARDWARE PROVIDED.ATTACHMENTS 514ALL BE DESIGNED t0 R R I �� C DESIGN PLLC '1' �-�'�� ® ? "BLOWER. PANEL. OPEN TO I MASTER CLOSET j - - RESIST THE COMPONENT AND CLADDING LOADS DETERMINED IN ACCORDANCE �5 RICK 'y/� E-MAIL: O I WITH EITHER TABLE R3012(2)OR AWE 1,WITH THE PERMANENT DC FILING@DCARCH-NY.COM OUJ t I a 1 6' t I GABD t O ►nR�'1ANENtLYINS7ALLED C>r�l THBUILDINCs ATTACHMENT IN ACCORDANCE ` y ''�` `� II HIS �} I DOOR I �� I - CONY PROPOSED x I I - � P z CHANDELIER v ; C OS T -- C O T ' ZI X 4" In WOOD WITH TABLE R3012.12 IS PERMITTED FOR BUILDINGS WITH A MEAN ROOF HEIGHT `p= M m PROPOSED , -- — i (BRAZILIAN WALNUT) OF 45 FEET(13,128 MM)OR LESS WHERE THE ULTIMATE DESIGN WIND SPEED, r z0 THIS EDITION OF THE CODE OUTREACH PROGRAM DISCUSSES THE ENVELOPE EXPOSED CENTERED OVER THE TIGHTNESS TEST,COMMONLY REFERRED TO AS "BLOWER DOOR TESTING," 2" x 6" In FOYER AREA. ��� i 91_0H DECKING. a WLT,IS 180 MPH OW KPH)OR LESS. N w r r.: -k- , DC REQUIRED BY THE "RESIDENTIAL PROVISIONS"OF THE 2015 INTERNATIONAL J JOISTS EQUALLY t CLG.HT. t �A p Q- J B II t G I ! J �42()3� ENERGY CONSERVATION CODE 11015 IECC),AS MODIFIED BY PART 3 OF THE I SPACED WA/-6" 3-I/2 X 14 BCI 90 20 WOOD I-JOISTS t �\ Tc y0 2016 SUPPLEMENT TO THE STATE ENERGY CONSERVATION GONSTRUCtION OF DAYLIGHT INSTALLED o 16" O.C. ti- .n.,.I' II FIREPLACE II I ; WINDBORNE DEBRIS PROTECTION FASTENING St: OP NEB "ALTERATION OF THIS DOCUMENT CODE(2016 ECS).THE TEST,WHIC;F� IS DEFINED BELOW,IS MANDATORY FOR X 30 X 96 PICTURE FRAME 30 X 96 II P EX E EXCEPT AL LICENSED ALL NEW RESIDENTIAL BUILDINGS,INCLUDING MODULAR RESIDENTIAL BETWEEN JOISTS I SCHEDULE FOR WOOD EXCEPT BYA L18 ICENSED BUILDINGS,MULTI-FAMILY BUILDN'�S,,AND THERMALLY ISOLATED I LOUVER I POCKET DOOR STYLE 44" Ill POCKET DOOR ® ! STRUCTURAL PANELSa,b,c,cl SDI 14 pl �- X _ - M a MODIFICATIONS TO EXISTING BUILDINGS. A,gS�BL VL 2.1E 3100 HEADER FASTENER SPACING(inches)a,b WHILE A 'BLOWER DOOR:"TESL IS REQUIRED FOR MODULAR HOMES(ALSO 14 6' KNOWN AS FACTORY MANUFACTURED HOMES),THE TEST IS NOT REQUIRED FOR MANUFACTURED HOMES('ALSO KNOWN AS HUD HOMES)WHICH ARE FASTENER TYPE Panel 4 feet< 6 feet< MANUFACTURED IN COMPLIANCE UlITH APPLICABLE DEPARTMENT OF HOUSING +� ,, ) ��+°� o spans pane!span panel span AND URBAN DEVELOPMENT(HUD)MANUFACTURED HOME CONSTRUCTION AND cn � e Q Q -�Q �.. .mom. °::.. SAFETY STANDARDS(24 C FR PART 3280).DEFINITIONS OF THE TERMS - 4 feet s 6 feet s 8 feet "FACTORY MANUFACTURED HOME"AND "MANUFACTURED HOME"ARE FOUND IN THE 2011 UNIFORM CODE SUPPLEMENT. _ ® �� $ SHELF BETlCH 70 cONo.8 wood screw based WORK PERFORMED IN EXISTING BUILDINGS GENERALLY DOES NOT TRIGGER A m NEW 24 X 96 (�D '- e 0 DOB EMPLOYEE T BLOWER DOOR TEST UNLESS THE WORK AREA IS THERMALLY ISOLATED FROM POCKET DOOR Ni CFM O v anchor with 2-inch embedment 16 10 8 o STAMPS AND SIGNATURES EXISTING CONSTRUCTION,THE REASONING IS THAT ONCE EXISTING INSTALLED O.C. PROPOSED �� ;K w �: �: TILE FLOOR length CONSTRUCTION IO NOT SUI5JEC7 t0 TESTING,AND MAY NOT COMPLY WITH THE �' '" C� _ C4 / OVER Q z No.10 wood screw based PRESCRIBED INFILTRATION THRESHOLD,TESTING BOTH AREAS WOULD , PROPOSED POTENTIALLY INVALIDATE THE TEST RESULTS.FOR MORE INFORMATION ON THE I OOM SD ? 6 5AAR 6' "n PROPOSED RADIANT HEAT ' �u A I anchor with 2-inch embedment 16 12 9 SUBJECT,REFER TO THE TECHNICAL BULLETIN THAT IS LISTED AS AIR _ BEDR C9'_011 12 M ;� co length INFILTRATION ON OUR TECHNICAL SUPPORT WEBPAGE,OR DOWNLOAD IT BY ,n }3ATHROOM D/W MASTER // _ X - - g CLICKING HERE. BEDR THE CODE SECTIONS THAT FEQUIRE "BLOWER DOOR"TESTING ARE:AS � o � O IO N 69D CLG Ht N t/11 inch lag screw based anchor FOLLOWS: O� N g'-0" -F ��RO 16 16 16 1015 IECC,SECTION R40;>.4 AIR LEAKAGE(MANDATORY),AS MODFIED BY THE _ _ t CLG.HT. POSED = with 2-inch embedment length 2016 ECS: THE BUILDING THERMAL.ENVELOPE SHALL BE CONSTRUCTED TO (P I 3-1/1" X 14" BCI 90 20 WOOD I-JOISTS ` "TASTER BATH _ I LIMIT AIR LEAKAGE IN ACCORDANCE WITH THE REOUIREMENTO OF SECTIONS °' °' 70 I R402AJ THROUGH R402A•b. CFM j � � � FOR SI: 1 INCH ■ 25.4 MM,1 FOOT ■ 3048 MM,1 POUND " 4.448 N,i MILE PER 2015 IECC,SECTION R402A.12 (TESTING),AS MODIFIED BY THE 2016 ECS: THE I HOUR■ 0.441 M/S. BUILDING OR DWELLING UNIT SHALL BE TESTED AND VERIFIED AS HAVING AN X b' ��, ° THIS TABLE IS BASED ON IW MPH ULTIMATE:DESIGN WIND SPEEDS,WILT,AND A �. �; 45-FOOT MEAN ROOF HEIGHt.AIR LEAKAGE RATE NOT EXCEEDING THREE AIR CHANGES PER HOUR TESTING i FASTENERS SHALL BE INSTALLED At OPPOSING ENDS OF THE WOOD SHALL BE CONDUCTED IN ACCORDANCE WITH Ill E 119 OR ASTM E 1821 AND ' ^ R II REPORTED AT A PRESSURE OF 0.2 INCH W.G....WHERE REQUIRED BY THE CODE i 5-I/4 X 14 VERSA-LAM 1 `� 70 : it STRUCTURAL PANEL.FASTENERS SHALL BE LOCATED NOT LESS THAN I INCH LYL 2.1 E 3100 HEADER % -1/4 X 14 VERSA-LAM SHEETTITL!° OFFICIAL,TESTING SHALL BE CONU3UCTED BY AN APPROVED THIRD PARTY ... 3-112" X 14" BCI 90 2.0 WOOD I-JOISTS g A (,FM ANCHORS E 7 THE 2015 IECC,AS MODIFIED BY THE 2016 ECS,DEFINES "BUILDING THERMAL103 t SIM R ROUGH THE EXTERIOR WALL COVERING WITH AN ENVELOPE:"AS: to I ll 6 Y EMBEDMENT LENGTH OF NOT LESS THAN 2 INCHES INTO THE BUILDING FRAME. THE EXTERIOR WALLS(ABOVE AND BELOW GRADE),FLOOR ROOF,AND ANY ® - FASTENERS SHALL BE LOCATED NOT LESS THAN 21/2 INCHES FROM THE EDGE OTHER BUILDING ELEMENTS THAT ENCLOSE CONDITIONED SPACE OR 5-114" X 14" VERSA-LAM O 11 OF CONCRETE BLOCK OR CONCRETE. LVL 2.1E 3100 HEADER PANELS ATTACHED TO MASONRY OR MASONRY/STUCCO SHALL BE ATTACHED SECOND FLOOR PROVIDESBOUNDARY BETWEEN CONDITIONED SPACE AND EXEMPT OR N USING VIBRATION-RESISTANT ANCHORS HAVING AN ULTIMATE WITHDRAWAL THE 7Est REQUIREMENTS ARE MODIFIED BY THE 2016 ECS BY ADDING AN ROOF CAPACITY OF NOT LESS THAN 1,500 FOUNDS. OPTIONAL TEST PROCEDURE FOR BUILDINGS WITH TWO OR MORE DWELLING [`BELOW ® PROVIDE CONTINUOUS TOP PLATES OVER BRACED UNITS(SEE 2015 IECC SECTION R4WA13,AS ADDED BY THE 2016 EC WALL LINE.8D COMMON NAILS a 4" O.C.AT BRACED PP TEST PROCEDURE ALSO ALLOWS FOR EVALUATION OF EACH PANEL PERIMETER AND SD COMMON NAILS � 12 PLAN DWELLING UNIT BASED ON A MAXIMUM OF 03 CFM PER SQUARE FOOT OF " ENCLOSURE SURFACE AREA WITHIN THE TESTING AREA t0 PUT IT SIMPLY,THE A O.C.THROUGHOUT INTERIOR SUPPORTS. "ENCLOSURE SURFACE AREA" IS THE SUM OF THE CONDITIONED SURFACES OF THE DWELLING UNIT(WALLS,FLOOR AND CEILING).SECTION R402.413.1 OF 3'-11" 3'-Il" 1'-2" T_ ` SECTION R308.4 1'-9" 2'-011 14'-4" 25'-6" '01 EACH PANE OF GLAZING INSTALLED IN HAZARDC>LIS LOCATIONS MUST BE 25'-6" 26'-0° 10 DOB NOW PI OJECT NUMBER PROVIDED WITH A MANUFACTURER'S OR INSTALLER'S LABEL,DESIGNIATING THE TYPE AND THICKNESS OF GLASS AND THE SAFETY GLAZING STANDARD 68'-�3" WHICHWITH COMPLIES.THE LABEL NEEDS TO BE VISIBLE AT THE FINAL BSCAN INSPECTION,AND It MUST BE ACID-ETCHED,SANDBLASTED,CERAMIC-FIRED, OR AN EMBOSSED MARK OR C�THE TYPE WHICH ONCE APPLIED CANNOT S COT VD FLOOR P�fi BE REMOVED WITHOUT BEING DESTROYED. Ir SCALE: 1,14" = 1'-0" DRAWING No. SHEET No. A=4 6 OF 16 CONSULVAH72 ARCHITECT OF RECORD: DAVID CHAGNON,ARCHITECTURAL DESIGN PLLC E-MAIL: DC_FILING@DCARCH-NY.COM "ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL fS ILLEGAL" NEW CORNICE TO BE TRIMMED IN EXPOSED 2" x 6" In JOISTS IPE.CONTRACTOR TO PROVIDE AN EQUALLY SPACED W/+/-6" OF ALTERNATE PRICE FOR CORNICE HORIZONTAL HATCH DENOTES NEW DAYLIGHT BETWEEN JOISTS TO 57 TO BE BLACK SHEET METAL. BOARD FORM CONCRETE.BOARD CREATE A LOUVER ASSEMBLY. WIDTH AND CONCRETE COLOR TO 4"X 8" In LOW BEAM TO / BE SELECTED. SUPPORT In LOUVER ASSEMBLY. fJ NEW TOP OF PARAPET_ _ CREATE!DESIGN/BUILD GROUP NEW 2ND TOP OF ROOF DECK E� ARCHITECTURE-ENGINEERING-CONSTRUCTIONcn ' EL. +21'-2° E-MAIL:MMUNOZ@CREATEDESIGNBUILDGROUP.COM - NEW 2ND FLOOR TOP PLATE TEL:631-464-6668 PROPOSED I" X 4" In (EIRAZILIAN WALNUT) SIDING INSTALLED VERTICALLY OVER 1-1/211 DEEP FURRING STRIPS,OVER R-5 RIGID t INSULATION AND 1/2" CDX PLYWOOD. I 0 � I NEW FIXED WINDOW,SEE WINDOW SCHEDULE. EXTERIOR SILL AND ADJACENT SURFACES TO _ I BE TRIMMED IN IPE. BECKY SHEA DESIGN _ BECKY@BECKYSHEA.COM NEW 2ND FLOOR _ _ ____. REVISION DATE DESCRIPTION M NEW 1ST FLOOR TOP PLATE #1 10.24.24 P.E. COMMENTS NEW CORNICE t0 BE TRIMMED IN IPE. : EXPOSED 3" x 8" In COLUMNS EQUALLY SPACED W/+/-8" OF DAYLIGHT BETWEEN HORIZONTAL HATCH DENOTES NEW JOISTS TO CREATE A CONSTRUCTION ADMINISTRATION BY: BOARD FORM CONCRETE.BOARD ' WIDTH AND CONCRETE COLOR TO LOUVER ASSEMBLY. BE SELECTED. PROPOSED I" X 4" In TO BE DETERMINED (BRAZIL IAN WALNUT) DECKING THROUGHOUT CLIENT: DATE: SCALE: EXTERIOR WRAP ALONZO FAMILY 12/24/22 AS SHOWN AROUND PORCH. NEW FIN. 1ST FLOOI� ' . • CLIENT/ADDRESS/SCOPE OF WORK 0.1 R I V am T E i K S I D C El FRONT ELEVATION CEDARS ROAD SCALE: 1/4" a 1'-011 CUTCHOGUE, N.Y. NEW RESIDENCE ARCHITECTURAL SEAL: ARCHITECT OF RECORD: DAVID CHAGNON, ARCHITECTU�P2'ED ARC DESIGN PLLCE-MFtAL NEW \ ?0 C/t C DC FI ING@DCARCH-NY.COM IPE.CIL ONTRACCTOI B O PRI OVIDEI AN w� Q�� ALTERNATE PRICE FOR CORNICE yG� TO BE BLACK SHEET METAL. * e; O �N�EW TOP OF PARAPET ,.. D C �N�E1W 2ND TOP OF ROOF DECK m T �. +21'-2" OF N � "ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED ' ' 3 ` ! ' PROFESSIONAL IS ILLEGAL" NEW 2ND FLOOR 'TOP PLATE _ E � I I 1 ' I I �.. +20 -1 PROPOSED I" X 4" In (BRAZILIAN WALNUT) SIDING INSTALLED VERTICALLY OVER 1-1/2" I I DEEP FURRING STRIPS,OVER R-5 RIGID INSULATION AND 1/2 CDX PLYWOOD. 1 # ! 0 NEW WINDOW,SEE; WINDOW SCHEDULE. I I EXTERIOR SILL AND ADJACENT SURFACES I I I TO BE TRIMMED IN IPE. HORIZONTAL HATC14 DENOTES NEW €` BOARD FORM CONCRETE.BOARD DOB EMPLOYEE STAMPS AND SIGNATURES -------------- WIDTH AND CONCRETE COLOR TO NEW 2ND FLOOR BE SELECTED. -A,-NEW 1ST FLOOR TOP PLATE _ NEW EXTERIOR INSULATION FENESTRATION SYSTEM (EIFS)TO BE INSTALLED OVER EXTERIOR SHEATHING.STUCCO COLOR TO BE SELECTED BY W)MEOWNER 4 1 PROPOSED 6 SQUARE STEEL COLUMNS IN E —' FLAT BLACK"I 2ND FLOOR DECK SUPPORT. - STYLE AND FINISH TO BE APPROVED PRIOR e TO ORDERING. {{{ g PROPOSED I" X 4" In (BRAZILIAN WALNUT) SHEET TITLE DECKING THROUGHOUT EXTERIOR WRAP s$ ` AROUND PORCH. o, i NEW//�FIN. )•IS-T_FLOOR EVA T'I® *, LEFT SIDE ELEVATION SCALE: 1/4" 1'-0" DOB NOW PROJECT NUMBER BSCAN DRAWING No. SHEET No. mill OF 16 { © C 2 0 9 H CONSULTAN70 ARCHITECT OF RECORD: DAVID CHAGNON,ARCHITECTURAL DESIGN PLLC E-KIAIL: DC_FILING@DCARCH-NY.COM "ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL IS ILLEGAL" NEW CORNICE TO BE TRIMMED IN IPE.CONTRACTORTO PROVIDE AN ALTERNATE PRICE FOR CORNICE TO BE BLACK:44EET METAL. NEW TOP OF PARAPET_ r EL. +22'-9" CREATE! DESIGN/BUILD GROUP ARCHITECTURE-ENGINEERING-CONSTRUCTION E-MAIL:ti1MUNOZ@CREATEDESIGNBUILDGROUP.COM NEW 2ND TOP OF ROOF DECK TEL:631-464-6668 ELW 2ND FLOOR TOP PLATE .+20'-1" PROPOSED I" X 4" In (BRAZILIAN WALNUT) SIDING INSTALLED VERTICALLY OVER 1-1/2" : DEEP FURRING STRIPS,OVER R-5 RIGID INSULATION AND 1/2" CDX PLYWOOD. e NEW WINDOW,SEE WINDOW SCHEDULE. iT EXTERIOR SILL AND ADJACENT SURFACES ' BECKY SHEA DESIGN TO BE TRIMMED IN IPE. ' ' BECKY@BECKYSHEA.COM NEW 2ND FLOOR � � � • REVISION DATE DESCRIPTION - #1 10.24.24 P.E. COMMENTS NEW 1ST FLOOR TOP PLATE _ NEW EXTERIOR INSULATION FENESTRATION SYSTEM(EFS)TO BE INSTALLED OVER CONSTRUCTION ADMINISTRATION BY: EXTERIOR SHEATHING.STUCCO COLOR TO BE SELECTED BY HOMEOWNER TO BE DETERMINED PROPOSED I" X 4" PIE: (BRAZILIAN WALNUT) CLIENT: DATE:ALONZO FAMILY 12/24/22 AS SHOWNDECKING THROUGHOUT EXTERIOR WRAP AROUND PORCH. CLIENT/ADDRESS/SCOPE OF WORK ANEW FIB_FLOOR PRIVATE Irmt E S I D C E rM'f/\I"'4/nrr. iu nNIAPYr n*rrl //I IIAAIn hl rJ1/1T"f/nrr. /II nN1Al'tf" n'Ff-rl �./I IIAA In I►I REAR ELEVATION CEDARS ROAD SCALE: 1/411 • 1'-0" CUTCHOGUE, N.Y. NEW RESIDENCE ARCHITECTURAL SEAL: ARCHITECT OF RECORD: DAVID CHAGNON, EKED ARC ARCHITECTURAL DESIGN PLLC \� gick �� DC FILING@DCARCH-NY.COM NEW CORNICE TO BE TRIMMED IN j. E-MAIL: IPE.CONTRACTOR To PROVIDE AN � G,P� - w - - - - - - - - ALTERNATE PRICE FOR CORNICE - - - - - - - - e. �NEW TOP OF PARAPET To BE BLACK SHEET METAL. - �'EL. +22'-31 - - O A�NEW 2ND TOP OF ROOF DECK M DEL. +21'-211 - 042 3`� .�© NEW 2ND FLOOR TOP PLATE <; % E L. +2�'-1 I I_ - - - - _ - _ - - - - - OF N "ALTERATION OFT IS DOCUMENT EXCEPT SY A LICENSED • „ PROFESSIONAL IS ILLEGAL" PROPOSED 1" X 4" In (BRAZILIAN WALNUT) SIDING INSTALLED VERTICALLY OVER 1-1/21' : DEEP FURRING STRIPS,OVER R-5 RIGID INSULATION AND 1/211 CDX PLYWOOD. : 61 NEW FIXED WINDOW,SEE WINDOW SCHEDULE, EXTERIOR SILL AND ADJACENT SURFACES To 5 / u BE TRIMMED IN IPE. EXPOSED 3" X 8" In COLUMNS EQUALLY DOB EMPLOYEE STAMPS AND SIGNATURES NEW 2ND FLOOR _ SPACED W1+1-8" OF DAYLIGHT BETWEEN EL. +11'-3" JOISTS t0 CREATE A LOUVER ASSEMBLY. ANEW 1st FLOOR TOP PLATE NEW CORNICE TO BE TRIMMED IN IPE. CONTRACTOR TO PROVIDE AN ALTERNATE PRICE FOR CORNICE to BE BLACK SHEET METAL. GARAGE DOOR: B 8'-0' WIDE X 8'-0" TALL STYLE,MAKE ,AND MODEL TO BE SELECTED BY HOMEOWNER PROPOSED 1" X 4" In (BRAZILIAN HORIZONTAL HATCH DENOTES NEW BOARD - '- - �"E4 _ I WALNUT)DECKING THROUGHOUT FORM CONCRETE.BOARD WIDTH ANDI!� EXTERIOR WRAP AROUND PORCH. CONCRETE COLOR TO BE SELECTED. j SHEETTITLE IL-11 IL L- NEW FIN. 1ST FLOOR . I ELEVATIONS RIGHT SIDE ELEVATION SCALE: 11411 1'-011 7n DOB NOW PROJECT NUMBER BSCAN DRAWING No. SHEET No. A=6 8 OF 16 i NEW CHIMNEY TO BE WRAPPED WITH STONE VENEER TO BIE SELECTED. © 0 ALL CHIMNEY CLEARANCE DIMENSIONS COMPLY WITH NFPA 54 AND ANSI Z223.1, SECTION 1052.1 RECORD:ARCHITECT OF DAVID CHAGNON ARCHITECTURAL DESIGN PLLC TYPICAL ROOF CONSTRUCTION E-MAIL: DC_FILING@DCARCH-NY.COM NEW ROOF DRAIN ASSEMBLY(TYPJ- r "ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL IS ILLEGAL" • SCREEN IN CAST ALUI'11NUM COVER WITH �"�A"zSE-N�LY NEW ROOF PECK TO RECEIVE SOLAR NEW EPDM ROOFING ASSEMBLY (FROM TOP TO BOTTOM PANELS.GENERAL CONTRACTOR TO WORK (2)LAYERS OF 151b.FELT AS PER(R9W52.1) BITUMEN MEMBRANE FLASHING SEALED TO - EPDM ME1 15RANE IN CONCERT WITH SOLAR PANEL INSTALLER •NEW 3/411 CDX PLYWOOD. CROSS BLOCKING.FILL JOINT WITH - INSULATION OVERLAY BOARD TO PROVIDE PROVISIONS FOR THE NEW 3-1/2" X 14" BCI 90 2 0 WOOD POLYURETHANE IINSUL.ATING FOAM. - RIGID THERMAL INSULATION INSTALLATION OF THE PROPOSED ROOF PROVIDE INSULATING SHEATH FOR STORMI-JOISTS INSTALLED 0 ib" O.C. - VAPOR BARRIER MOUNTED SOLAR PANELS.ALL ROOF *. DRAIN PIPE INSIDE ROOF DECK AND - 3/411 CDX PLYWOOD PENETRATION ARE TO BE SEALED WATER 24 GAUGE SLOPED NEU) TOP_ OF PARAPET EXTERIOR WALL.PITCH NEW ROOFING TIGHT AND ARE TO BE TESTED FOR LEAKS CAP FLASHING. EL. +22'--I" - ASSEMBLY TOWARD DRAIN AS REQUIRED. PRIOR TO COMPLETION. NEW 2"X 6"WOOD STUDS ' NNEW _TOP OF ROOF DECK PROPOSED ROOF TOP DECK PLYWOODINSTAL ON 1�0�DES. x rn '�' �L. +21'-611 - -- - DBL.2" X 6"TOP PLATE. !/ NEW 2ND FLOOR TOP PLATE _ NEW EXTERIOR SIDING VARIES. CREATE! DESIGN/BUILD GROUP EL. +20'-3" I1 SEE ELEVATION. ARCHITECTURE-ENGINEERING-CONSTRUCTION E-MAIL:MMUNOZ@CREATEDESIGNBUILDGROUP.COM LI/2 GYP.BD.SECURED TO NEW PROVIDE R-30 BATT. INSULATION TEL:631-464-6668 PRI-WW2 PERFORMANCE RATED IN CEILIWs ASSEMBLY. NOTE: I-JOIST CEILING JOISTS+ 16"O.C. CONTRACTOR TO VERIFY THE PROPOSED BEDROOM 04/ PROPOSED HALL LOCATION OF ALL PREDETERMINED mm oFFIt PROP, ER-OPOSED POINT LOADS AND PROVIDE Arf 6l 1/2"GYP.BD.SECURED TO NEW CONTINUOUS STRUCTURAL SUPPORT 6, 2"X 4" INTERIOR WALL STUDS G OS T DOWN TO FOUNDATION.ANY PROVIDE NEW STAIRS DOWN TO NEW BAF>EMEINT AND INSTALLED , Irv"O•C_ UNFORESEEN POINT LOADS ARE TO UP t0 NEW SECOND FLOOR AS REQUIRED. DOUBLE �, BE BROUGHT TO THE ATTENTION OF UP ALL FRAMING AROUND STAIR AND"ZOVIDE JOIST I!2W I THE ARCHITECT OF RECORD. HANGERS a ALL CONNECTIONS. MINIMUM b'-8" HEAP !I Ii it j ANEW 2ND_ FLOOR _ 1 HEIGHT. PROVIDE 36"HIGH HANDRAIL WITH „ BECKY SHEA DESIGN SPINDLES SPACED MAXIMUM a"APART 70 CODE. r !!_ 1 -_- i _-!II l _ !_�I11_ Nam_ BECKY@BECKYSHEA.COM -"- ALL PROVIDED ELECTRICAL WORK _.____._._____-_ IS TO BE INSTALLED IN NEW IST FLOOR TOP PLATE _ - � A C.ORDANCE WITH THE 2020 REVISION DATE DESCRIPTION N EL. ----------_-_---_ __--_—_-______ NYSBC,THE 2018 INTERNATIONAL #1 10.24.24 P.E. COMMENTS SECTION R408 UNDER-FLOOR-SPACE CONTRACTOR TO PROVIDE RESIDENTIAL CODE CHAPTER 34 t0 l2)1.15" X 125"ML HEADER -___--_- 43 AND THE NATIONAL ELECTRIC R4082 OPENINGS FOR UNDER-FLOOR VENTILIATION BLOCKED SOLID r0 UNDERSIDE v -- LINE OF DINING ROOM CEILING BEYOND. CODE I THE NFPA AL OF FLOOR JOISTS. �__ -- - 10. ROOF THE MINIMUM NET AREA OF VENTILATION OPENINGS SHALL BE NOT LESS THAN I SQUARE FOOT(0.0929 M2)FOR EACH 150 SQUARE FEET(14 M2) TYPICAL EXTER W L CONSTRUCT ON I --- PROPOSED OF IANDER-FLOOR AREA.ONE VENTILATION OPENING SHALL BE WITHIN 3 PROP. MUD ROOM NEW SIDING STYLE VARIES(SEE ELEVATION) SUNKEN FLOOR CLERESTORY SPACE FEET('315 MM)OF EACH CORNER OF THE BUILDING.VENTILATION - , �� OPENINGS SHALL BE COVERED FOR THEIR HEIGHT AND WIDTH WITH ANY •NEW t1'RvEK HOUSEAWRAP,SEAMS TAPED *- --- PROPOSED FOYER PROI`'OSED NOTE: OF THE FOLLOWING MATERIALS PROVIDED THAT THE LEAST DIMENSION e " _. N A1'ROOM CONTRACTOR t0 LIMIT DISTURBING CONSTRUCTION ADMINISTRATION BY: • NEW 1/2 CDX PLYWOOD SHEATHING. Q DE P� OF THE COVERING SHALL NOT EXCEED 1/4 INCH 16.4 MMh CONTRACTOR TO INSTALL 1 STEPS r- 1/2"GYP.BD.SECURED TO NEW NEW 2 x 6 WOOD STUDS 16" O.C. _--_ -_=---- II B THE EXISTING UTILITIES WHILE 1. PERFORATED SHEET METAL PLATES NOT LESS THAN 0�10 INCH , r " INTO NEW SUNKEN MUD ROOM io 2 X 4 INTERIOR WALL STUDS TO BE DETERMINED NEW R-21 ECOtOUCH(a 1/2 )BAT? INSULATION FLOOR TREADS AND RISERS TO _ - INSTALLED 16"OC_ EXCAVATING FOR NEW POURED NEW 1/2 GYP.BOARD INTERIOR MATCH ADJACENT FLOORING. ;; -- 3/4"PLYWOOD SUBFLOOR OVER 3/4"PLYWOOD SUBFLOOR OVER ANY EXISTING UNDERGROUND UTILITY CLIENT: DATE: SCALE: 11.8 MM)THICK „ ______ GONCRETEE STOOP.DISCOVERY OF ALONZO FAMILY 12/24/22 AS SHOWN 2. EXPANDED SHEET METAL PLATES NOT LESS THAN 0.041 INCH(12 -- -�u- NEW t'RI-80/14 PERFORMANCE NEW 3-I/2 rC 14 BCI 90 2�WOOD " - RATED I-JOISTS w I6"O.C. I-JOISTS INSTALLED s I6" O.C. BROUGHT TO THE ATTENTION OF THE 2ND FLOOR MM)THICK 31_0u __ _ H ` " OR IGN OBJECT IS TO BE 3/4 PLYWOOD SUBFLOOR OVER _ 3. CAST-IRON GRILL OR GRATING. NEW_FIN. 1ST_FLOOR _ _ NEW 3-1/2" X 14" BCI 90 2.0 WOOD ARCHITECT OF RECORD. CLIENT/ADDRESS/SCOPE OF WORK 4. EXTRUDED LOAD-BEARING BRICK VENTS. m t1-• (d1-(d" I-JOISTS INSTALLED a 1611 O.C. PROPOSED 5. HARDWARE CLOTH OF 0.035 INCH(Ob9 MM)WIRE OR HEAVIER ,,• BOILER 6. CORROSION-RESISTANT WIRE MESH,WITH THE LEAST DIMENSION I—III=III= LI/2 GYP.BD.SECU!2ED t0 NEW 3-1/2 X 14 BCI 90 2fd 3/4" BEING V8 INCH(32 MM)THICK NEW BASEMENT CE IL INS,,r l fl—I 11_1 I1_1.i II n PROVIDE conk BLOCKING CONNECT EL.—1T-3" I - �i I =1 11= ��'OPOSED �' WOOD I-JOISTS INSTALLED * 16" OZ.WITH BATT UNDER Lo�4D BEARING wALLs. •.., _, -, NEW GONC!�ETE FOUNDATION WALL t FOOTING - ' . '.�. RESIDENCE R408.4 ACCESS _ NEW 2"POURED CONGREI'E INSULATION R-30. ;III—WITH CONT.WATERPROOF MEMBRANE At I -- GRAUJL :: I. =1 PERIMETER AND �5 REBAR DOWELS. 1ST FLOOR 1" N ACCESS SHALL BE PROVIDED 70 ALL UNDER-FLOOR SPACES.ACCESS - C I�- TI I =i iI- "-• SCREEDCOAT WITH 4 MIL.,CLASS I, ,•y - OPENINGS THROUGH THE FLOOR SHALL BE A MINIMUM OF 18 INCHES Bl' - j ,.•,. .�c• A A _ PROPOSED !;PROVIDE CONT.SILL SEALER t COPPER TERMITE tl T t � l -I I SPACE P.YG.VAPOR BARRIER -- n:.'. -APPLY ' OK' r0 FINISHED :''+' III(III SHIELD UNDER NEW 2" x 6"A.0 Q.SILL ABOVE 24 INCHES(451 MM BY 610 MM).OPENINGS THROUGH A PERIMETER = ;; EXISTING� RBiL' AT1op w�L PROPOSED -il " WALL SHALL BE NOT LESS THAN I6 INCHES BY 24 INCHES(401 MM BY c0 - _ II -_ _ — ' — —_ —_ —_ — — L• �'rHZQQM ;•., _ ;WALL AND SECURE 1/2 DIA.ANCHOR BOLTS+ 610 MIN).WHERE ANY PORTION OF THE THROWN-WALL ACCESS IS __ to#-,1 a> I__ :' ( - I III=1I!-I j I I -!il !I =. I ! li I i_I '.? -I"AIR SPACE CE_LAR '4 .•� = 11 6'-0"O.0 MAX PROVIDE A MIN.OF TWO BOLTS 111 I__I : '•: III--III--!I(- BELOW GRADE,AN AREAWAY NOT LESS THAN 16 INCHES BY 24 INCHES I -� I I =, ' -2"x4" ACQ STUDS 16"oc w/ACQ SHOE PLATE I'-m° CEDARS ROAD f III-- =LI � : = ==1 —III—!I = 1= =I!--) - !_'� �I. .__..-1_ %:r -R-15 BATT INSULATION i llP R SILL A7112 MIN FROM! A.COR1 R (401 MM BY 610 MM)61aALL BE PROVIDED.THE BOTTOM OF THE - 'I = =' '=--1 I'-1 I I-1 I 1=1 i-' I-i I I- I 1=1 .= I-1=111=1 I •� f - _- i I-1 -1.,-1 ,=I,I'I ,'_' �+ �± NEUJ BASEMENIT SLAB r III=_=! ; I_- I I -! �_= --1 -- ! -1/1"GYPSUM BOAF� 'NATIONAL GYPSUM'MOLD RESISTANT • .' I A R PRCX�F MEMBRANE.(( III- C U TC H O V U E N.Y. PROPOSED AREAWAY SHALL BE BELOW THE THRESHOLD OF THE ACCESS OPENING. - { _ I!--1 1=III-11!= - EL. - g -3 -1 1="�'� -I! =1! =1 I I-' -III_-!II I-=1 I11= I,!-' "' GYPSUM BOARD(PURPLE BOARD)OR EQUIVALENT. 2"RIGID IN:iUL. EXTEND i�.` -!I'--11- -- cONc. wasH.-i 1=I 1,000 GALLON THROUGH WALL ACCES.�i OPENINGS SHALL NOT BE LOCATED UNDER A -I -III= = :: rr'— - -- - PROPANE TANK - - _ _ _ — LL� ! �D `r - DOOR TO THE RESIDENCE. ! , _-_ - ,=1 I= - -- _ 2 ER SLAB. _ �{_ --. 1i=1f == == --! --III--II= - :•':' ..> ,,.•,. < ,...•�: , I I II I -- !=1!!_I I _ _ =i- I-rt-� �- -- -�, r, : _ _ _ _ -- - -- - - - I. 7 1 1 III - - r } .� —rl lei f- --1 I I--i I_I I :::ar': -_�--LEI I-I_I = I 1==i _I 1=1 =I -rtl I___ I_ _�- i= a i=1 - -1 i,_I Li-I I_i r-1 1--1 I-: :. : .. III-1 I_._ I I__I I --I 1- 1_I- r-� - - - III- 11 NEW RESIDENCE ;t _ _ =j 1=1 I_I=1 I -I i-.I I I_WW 4 THICK P.c.SLAB Li_ III=1 I L_-III=1 I I-1 I 1=1 I'�-X"4 CONC-t�Y- �_ 111= I ip_-�I =1 lil I 1=1 I_L:=1 I —III— -- -III- —III--III—I i `I !-11—III—I —III—III=1 --_I ----�_��__I L__�-=— I .— I=-i I r--, 1 __ ,_I 4 1 FRS.DRAINAGE *1 w/6X6 MO WELDED WIRE MESH LAPPED MIN.OF ONE FULL MESH t - _ II r-- " , I�!- _j -I 11--I I!=1 11-=1 I -I I I-!11=1 I!=1 I I--!I 1=1 1=1 I -III-_.I I I.=?,. m,I -I 1=i_I 1=1 I I-PIPE W/16 CRJWrzD_I-1 SCALE: N.T.S. WIRED TOGETHER,48"OG OVER 6"THICK BASE COURSE =i I 1 1 I =II =III=III=III=I i 1_l I =1 =11!--I 1!--_�I�e'- �=1 !=1 STONE t FABRIC CONSISTING OF CLE�N SAND,GRAVEL,OR CRUSHED STONE. I —) =i.!I==I 1!=I�=1- =III=III==I —Ii_�`III=� !_ !==I!=III=III==III=I( =BOIL SEPARATOR TO I. ARCHITECTURAL SEAL: ARCHITECT OF RECORD: - III I t 1!I! I-III-III=III=III=I I I=I I I=III-I_I I-=III=-III=_I_I =-_III_-III-III-III I_I-I DAY LIGHT _ - ; DAVID CHAGNON, I'' I =I II II I =.I_I I--III I I I III I:- R�D qR DESIGN PLLCARCHITECTU�L — — —_ — —_ " 5U I_ D I NCH CfiROSS SECTION I!_-1Ii i - - =1 cy� — I-I III--,_._--_._. g 1 C E-MAIL:E-MAIDCLFI ING@DCARCH-NY.COM TO 4 VENT TO 4 VENT TO 4 VENT TO 4"VENT SCALE_: 114" 1'-(0" I I)11I=-III-I =- I I--III—III_ "' �R k C I THROWH THROUGH THROUGH THROUGH I-1 I- !I 11y1 I'— [� p r `�1 n+t�'� c2A ROOF ROOF RC OF ". 1TI� �y4. ROOF NEW 042t339 0NEW 13ATHRM NEW 4- C - BATNRM. t'3 r NEW MASTER Or 'V G� "ALTERATION OF THIS DOCUMENT E%CEPT BY A LICENSED �3AR �.4_ LAUNDRY �3 TJ-IRl"I. 02 5ATI-(ROOM. PROFESSIONAL IS ILLEGAL' 2 n 211 211 2. r--------r--------r---T--- ----r-------r---r---�----j ----T--------r----1 ----�•-------- ---- w LLI V2"i I WI 21-i 1 1/2"i 1 V211 i I]V281 11/2"1 i 1 V2"i 2"i 1 V2"i 11/2"i 2"1 11/2", 1 V2"i _z z I I I I I I I I I I I I I I I I NEW I i i NEW I i i NEW. NEW. i i i NEw. I i NEW. i NEW. SINK i I LAv.i i i Av1 S I NEW R LAV. i i i LAY. i LAV. j E- NEW i WW i NEW i NEW W W I W.C. NEW I W.G. NEW I wc. NEW I W.G. �(/ ol 2ND FLOOR 2" NEW I 2" SHMME 2 I I/2' SWUJE 2" SHOWE 2" 2" O 4 s°' Q�P �A �5 ° " N O� DOB EMPLOYEE STAMPS AND SIGNATURES =" n 2 $" 3n 2" 1 " 2" 3" 2" 2u 3N 2" 2" ✓� I NE UJ KITCHEN NEW PiUi DR.� RM, sc- ----2l- --- ----i 47.59 91 .24' 1I/2" 111/2" 20 I 11/1" IIR" O O O O I I II NEWT NEWT INEW I ,SW hEWHW�SHER LAv.I LAV. FRONT ELEVATION NEW W 211 "�" we 2" z J SEE SITE PLAN FOR z 1/2" r1 1srFLooR II 211 CORRESSPONDING DIMENSIONS �I SHEET TITLE NEW r4f=7uJ B,ATNRM. 2" EL s w BUILDING 5r------T---------7- -T- - Ael AfR 11/2"� 211� I I/2"� 4�O� /)>\/P lA� °, 0 NEW i NEW i �� 0- SKY SECTION, LAY. I I LAV.( I I I I TO SEPTIC SYSTEM NEw C.I.�WJSEPRAM o 56.04' 124.30' PLANE, w.c. 2" w I 2" AND PIPE O PLUMBING CzRIND SIDE ELEVATION PUMP SE DIAGRAM DOB NOW PROJECT NUMBER PLU" 51NG fiR16EfR D IAGFRAM 5<K' PLANE DfRAW NG& BSCAN SCALE: N.T.S. SCALE:: 1116" = 1'-0" DRAWING No. SHEET No. AN 9 CF 16 R905.25 FASTENERS FASTENERS FOR.ASPHALT SHINGLES SHALL BE GALVANIZED STEEL,STAINLESS STEEL, 7 12" USE A MINIMUM OF 1` !� ALUMINUM OR COPPER ROOFING NAILS,MIN. 12 GAGE SHANK W/A MIN.J"HEAD _ 1 SIDE OF TRUSS. THREE 8d NAILS 7HIS "� ASTMF1667,OF A LENGTH TO PENETRATE THROUGH THE ROOFING MATERIALS AND 1 'I A MIN.OF J"INTO THE ROOF SHEATHING.WHERE THE ROOF SHEATHING IS LESS THAN • /• �� ARCHITECT OF RECORD: THICK.THE FASTENERS SHALL PENETRATE THROUGH THE SHEATHING R905.26 ASPHALT \ DAVID CHAGNON,ARCHITECTURAL DESIGN PLLC ROOF SHINGLES SHALL HAVE A MIN.OF SIX FASTENERS PER SHINGLE WHERE THE ROOF __ _ \ E-MAIL: DC-FILING@DCARCH-NY.COM IS IN ONE OF THE FOLLOWING CATEGORIES-THE BASIC WIND SPEED PER R301.2(4)IS 110 =_ \ "ALTERATION OF THIS DOCUMENT EXCEPT ST A LICENSED PROFESSIONAL IS ILLEGAL" MPH OR GREATER AND THE EAVE IS 20'ABOVE GRADE R905.27 FOR ROOF SLOPES FROM ;� SIMPSON MODEL TWO VERTICAL UNITS IN 12 UNITS HORIZ.UP TO FOUR UNITS VERT.IN 12 UNITS HORIZ. MST27 OR 1-1/2"W 20ga. UNITS SHALL BE TWO LAYERS. F1 °° ° ° ° METAL STRAP ' p� ,aDJUSTA5L wANC-sE, D2 iLSTAIS ID E DOLSU26-2X&(CTUfiRA�. IIDGE SIMPSON STRONG-TIE PSON STRONG-TIE PSON STRONG-TiE O IMPSON LSU26-2X6 WITH(3)8d COMMON NAILS IN NAILS ° STRONNG LSSU28-2X8,2XIm,OR 2X12 LOCATED AT EACH END OF STRAP LSSU28-2X:3,2XImpR 2X12 INTO ° STRONG-TIE Ac A.COMMON OR BOX NAILS.ARE PERMITTED TO BE USED EXCEPT WHERE OTHERWISE STATED LOCATED TAT EACH H END STROP TPLATE HREE °a SIMPSON B.NAILS SPACED AT 6"OC AT EDGES,12"AT INTERMEDIATE SUPPORTS EXCEPT 6"AT SUPPORTS a WHERE SPANS ARE 48"OR MORE.FOR NAILING OF WOOD STRUCTURAL PANEL AND PARTICLE CD r I� "*TR�_ OI�►•� �OS►TC/��Oti�L1�1i�tION� \ �a �BOARD DIAGRAMS AND SHEAR WALLS,REFER TO SECTION 2305.NAILS FOR WALL SHEATHING T'11.F1� k1`+ i y1�11� C I CREATE!DESIGN/BUILD GROUP ARE PERMITTED TO BE COMMON,BOX OR CASING. SIMPSO -TIE H12 81MF'SON STRONG-TIE AC c a / ARCHITECTURE-ENGINEERING-CONSTRUCTION C.COMMON OR DEFORMED SHANK. OR I-1/4 x 2m ge.STRAP SIMPSON STRONG-TIE Hi ` / E-MAIL:NIMUNOZ@CREATEDESIGNBUILDGROUP.COM D.COMMON. — TEL:631-464-6668 E.DEFORMED SHANK. MST27 F.CORROSION RESISTANT SIDING OR CASING NAILS. ° HD2A G.FASTENERS SPACED 3"OC AT EXTERIOR EDGES AND 6"OC AT INTERMEDIATE SUPPORT. ° CS20 -- H.CORROSION RESISTANT ROOFING NAILS WITH�"DIA HEAD AND 1 "LENGTH FOR+" ° ° ° AT CORNERS 0-0 SHEATHING AND I J"LENGTH FOR f"SHEATHING. o c0. I.CORROSION RESISTANT STAPLES WITH NOMINAL 16'CROWN AND I I'LENGTH FOR SHEATHING AND 1 I"LENGTH FOR�"SHEATHING.PANEL SUPPORTS AT 16"(20"OF STRENGTH AXIS IN THE LONG DIRECTION OF THE PANEL UNLESS OTHERWISE MARKED) ;•, `. o SIMPSON MODEL \ J.CASING OR FINISH NAILS SPACED 6"ON PANEL EDGES, 12"AT INTERMEDIATE SUPPORT. i''` � MST27 OR 1-1/2"W 20gA K.PANEL SUPPORTS AT 24".CASING OR FINISH NAILS SPACED 6"ON PA14EL EDGES, 12"AT �•�• o ® METAL STRAP INTERMEDIATE SUPPORTS. i I S D I.FOR ROOF SHEATHING APPLICATIONS,8D NAILS ARE THE MIN.REQ'D FOR WOOD STRUCTURAL t ' I A -�■ t o ® I BECKY ECKSHE DESIGN PANELS. /_ r-Agz- MOUNT HANGr=p, h`} 5,m 1 f I '� nQ 'POs I �s BECKY@BECKYSHEA.COM M.STAPLES SHALL HAVE MTN.CROWN WIDTH OF ". Q SiMPSON STRONG-TIE LUS 28 "' I SIMPSON STRONG-TIE HRC 22 TRONG-TIE ABA44 ° N.FOR ROOF SHEATHING APPLICATIONS,FASTENERS SPACED 4"OC AT EDGES,8"AT ° REVISION DATE DESCRIPTION INTERMEDIATE SUPPORTS. LTP4 #1 10.24.24 P.E. COMMENTS 0.FASTENERS SPACED 4"OC AT EDGES,8"OC AT INTERMEDIATE SUPPORTS FOR SUBFLOOR AND ;�. �\ 4 I I GRADE / WALL SHEATHING AND 3 OC AT EDGES,6 AT INTERMEDIATE SUPPORTS FOR ROOF SHEATHING. BP \/ o . P.FASTENERS SPACED 4"OC AT EDGES,8"AT INTERMEDIATE. (� CO R PLATE CUT �� SIMPSON STRONG-TIE HCP \ MINIMUM UNIFORM DISTRIBUTED DESIGN LOADS LENGTH ( REFER TO TABLE R301.4 OF THE RESIDENTIAL CODE OF NEW YORK STATE ) o LENGTH /_ 1'�sT2� STR�4P CONNEC•ION hETAIL rD CONSTRUCTION ADMINISTRATION BY: USE LIVE LOAD DEAD LOAD Bp Q SIMPSON STRONG-TIE MST21 OR 1-1/2" WITH 20 gga.METAL STRAP EXTERIOR BALCONIES 6O PSF lO PSF (4)Sd NAILS 12" MIN.BEARING ON STUD SU�ACE PLACED AT EACH TO BE DETERMINED B SIMPSON STRONG TiE STAP ANCHOR OLT.(48" FOR O.C. SLAB). DECKS 40 PSF 10 PSF a FOR I6INO C AS REQUIRED D PASSENGER VEHICLE GARAGES 50 PSF AS PER PLAN CLIENT: DATE: SCALE: ATTICS WITHOUT STORAGE ROOF BELOW 3 PITCH 10 PSF 10 PSF MST27 o CLEAR OVER TOP PLATE TO OTHER ALONZO FAMILY 12/24/22 AS SHOWN L SPAN SIDE OF STUD ATTICS WITH STORAGE ROOF BELOW 3 PITCH 20 PSF 10 PSF STUD TO RIM GIST H = STORY WALL HEIGHT CLIENTI ADDRESS/SCOPE OF WORK ROOMS OTHER THAN SLEEPING ROOMS 40 PSF 10 PSF L= � 1I t HEIHT SIMPSON STRONG-TIE CS2m METAL STRAP SH A W MEN SLEEPING ROOMS 30 PSF 10 PSF (3)Bd NAILS AT EACH END OF STRAP12"MIN. BEARING ON STUD SUFFACE PLACED AT WALL HT. (Hl SEGMENT WIDTH (L) STAIRS 40 PSF 10 PSF .• 48" O.C.WITH LTP4 ATTACHING MUDSILL t0 8'-1; 2'-4- STAIRS 9'-, " 2'-8" GUARDRAILS AND HANDRAILS 200 PSF 10 PSF MST27 END RIM JOIST V 10'-1 3'-0' PRIVATE ROOF LOADING LIVE—GROUND SNOW LOAD 30 PSF LENGTH H10 SSf SIMF'SON MODEL MST2'1 oR I-la" WITH 2m qa. - 1-1/4'SIMPSON CS20 OR METAL STROP l4)8d NAILS 12"MIN.BEARING IMI.SI®� 1-1/4 20 GA. GALV. ON STUD SURFACE PLACED AT EACH STUD. ROOF VENTILATION REQUIREMENTS .. ° ° ° r STRAPPING MIN. 12 . ENECE • ° ON STUD SURFACE RRR806.1 Ventilation required. Enclosed attics and enclosed rafters aces formed where ceilings area lied direct) to • (3 — 8d NAILS AT EA. the underside of roof rafters shall have cross ventilation for each separate space by ventilating openings protected against END OF STRAP) FFOR DOUBLE STUDS the entrance of rain or snow. Ventilating openings shall be provided with corrosion—resistant wire mesh, with 1/8 inch ° I CEDARS ROAD (3.2 mm) minimum to 1/4 inch (6.35 mm) maximum openings. SILL P�„■,I!�,TE To r-OUNDAT� o i� SIMPSON STRONCs-TIE MST21 OR 1-1/2" WITH :10 gga.METAL JO CONNECTION �+ }•� ' I}� /� C U TC H O G U E N.Y. §RR806.2 Minimum area. The total net free ventilating area shall not be less than 1 to 150 of the area of the space STRAP(4)Sd NAILS 12"MIN.BEARING ON STUD-SUi'a'FACE p�• STUi� TO STU17 CO14NECTiON SIMPSON PHD2-SQ_V 7 ventilated except that the total area is permitted to be reduced to 1 to 300, provided at least 50 percent and not more than PLACED AT 48" OZ. SIMPSON STRONG-TIE C:S2m sIMPSON STRONG-tIE Cs2m = THREADED RODS 8 80 percent of the requ''red ventilating area is provided by ventilators located in the upper portion of the space to be ventilated at least 3 feet (914 mm) above eave or cornice vents with the balance of the required ventilation provided by X C O N N E C T 1 0 N A N D N A 1 L I N G S C N E ID U L E ��E W RESIDENCE eave or cornice vents. As an alternative, the net free cross—ventilation area may be reduced to 1 to 300 when a vapor barrier having a transmission rate not exceeding 1 perm (57.4 mg/sm2Pa) is installed on the Warm side of the ceiling. I F A S T E N E R S DOUG-FlR LARCH_/$0 PINE UPLIFT SPRUCE-PINE-FlR UPLIFT UpIJFT ALLOWABLE LOADS z LOAD ALLOWABLE LOADS ),s LOAD §RR806.3 Vent clearance. Where eave or cornice vents are installed, insulation shall not block the free flow of air. A TO TO TO AVERAGE UPLIFT 133 160 8d x i\ UPLIFT 133 160 &1 m\ MODEL RAFTERS/ PLATES STUDS NAILS NAILS ARCHITECTURAL SEAL: ARCHITECT OF RECORD minimum of a 1—inch (25.4 mm) space shall be provided between the insulation and the roof 1/4" MIN•2D GAUGE I SEE PLAN FOR N0. Ga. TRUSS (133) (160) F) FZ 133& 160) (133) (160) F) Fz 133 do 160) T2 STORYOAPPUCAnONSR ARc�i ECTUR�L' sheathing at the location of the vent. COIL STRAP. FRS D AR DESIGN PLLC HEADER SIZE. H1 18 6-8d x 1\ 4-8d --- 1958 490 585 485 165 455 400 400 415 140 370 Cy FRAME OPENING FOR �� �RIC E-MAIL: E-MAIMG�DCARCH-NY.COM NEW WINDOW OR H2 18 5-8d --- 5-8d 1040 335 335 --- --- 335 230 230 --- --- 230 �� EXTERIOR DOOR H25 18 5-8d 5-8d --- 1300 415 4i5 150 150 415 365 365 130 130 365 SIMPSON PHD2-SDS3 HOLDOWN fl; Q . n WiTH SST-Bi6 ANCHOR BOLT PROVID JOIS SIMPSON CS20 OR H2.5A 18 5-8d 5-8d --- 1793 600 600 110 110 480 520 535 110 110 480 * O SIMPSON CS20 OR HANGERS AT 1-1/4" 20 GA. GALV. ,//2" C.D.X. PLYWOOD SHEATHIN AT EXTERIOR WITH 8d NAILS - - ,I� 1-1/4" 20 GA. GALV. DC RIM JOIST TO STRAPPING MIN. 12" H3 18 4-8d 4-8d -- 1433 455 455 125 160 415 320 320 105 i40 290 A'T 6' O.C. AT EDGES AND ®12�' O.C. IN THE FIELD tP :5~_.' STRAPPING MIN. 12 FLOOR JOIST ON STUD SURFACE ¢ ON STUD SURFACE (LUS28) 3 - 8d NAILS AT EA. H4 20 4-8d 4-8d --- 1144 360 360 165 160 360 235 235 140 135 235 142' GYP. BOARD"AT INTERIOR WITH 5d COOLER NAILS®7' O.C. -S7 OgZ839 0 (3 - 8d NAILS AT EA. END 8 STRAP) A EDGES AND 10 O.C. IN THE FIELD ��� END OF STRAP _/ -__ F E� OR H5 18 4-8d 4-8d 1485 455 465 115 200 455 265 265 100 170 265 *9L_ }■ 'II / M o��JJAB N, g /' !/ET7�I� "ALTERATION OF THIS NSED DOCUMENT H5A 18 3-8d 3-8d --- P,)00 350 420 115 180 290 245 245 100 120 170 EXCEPT BV A IS ILLEGAL' PROFESSX)NAL IS ILLEGA L" CANTILEVER ■� I `�p SCALE: 3/8" I'-m" n',1 C /l NT I L E Y E R H6 16 --- 8-8d 8-8d 3983 915 950 650 --- --- 785 820 560 --_ _-- SI fMPSON STRONG-TIE C820 AND LUS28 H7 16 4-8d 2-8d 8-8d 2991 930 985 400 -- 800 845 345 -- /L QEb CONNEVTIO H8 18 5-10d x 1\ 5-10d z i\ --- 2422 620 745 --- -- --- 530 565 --- --- --- p15 i/4"MIN 2m gf a`.COIL SCRAP H9KT 18 4-S01 It t\ 5-SDj z 1\ --- 2812 875 875 680 125 --- 755 755 680 125 --- TABLE R301.7 H10 18 8-8d x t \ -8d x 1 \ --- 3135 905 990 585 525 --- 780 850 505 450 --- ALLOWABLE DEFLECTION OF STRUCTURAL MEMBERS b,c STRUCTURAL MEMBERS ALLOWABLE DEFLECTION HIM 18 8-8d x i \ -8d x i \ --- 3135 905 990 585 525 --- 780 850 505 450 --- RAFTERS HAVING SLOPES GREATER THAN 3:12 DOB EMPLOYEE STAMPS AND SIGNATURES H10-2 18 6-10d 6-10d --- 2147 760 760 455 395 --- 655 655 390 340 -- WITH FINISHED CEILING ATTACHED TO RAFTERS L/180 H11Z 18 -i6d x 2 -16d x 2 --- 5L)97 830 830 525 760 --- 715 715 450 655 --- INTERIOR WALLS AND PARTITIONS H/180FLOORS L/360 CEIIJNGS WITH BRITTLE FINISHES (INCLUDING L/360 PLASTER and STUCCO) CEILINGS WITH FLEXIBLE FINISHES (INCLUDING GYPSUM BOARD) L/240 ALL OTHER STRUCTURAL MEMBERS L/240 EXTERIOR WALLS - WIND LOADS aWITH PLASTER H/360 OR STUCCO FINISH EXTERIOR WALLS - WIND LOADS °WITH OTHER BRITTLE FINISHES H/240 EXTERIOR WALLS - WIND LOADS °WITH FLEXIBLE FINISHES H/12 UN"ELS SUPPORTING MASONRY VENEER WALLS a L/600 NOTE, L= SPAN LENGTH, H = SPAN HEIGHT A.FOR THE PURPOSE OF THE DETERMINING DEFLECTION LIMITS HEREIN, THE WIND LOAD SHALL BE SHEETTITLI_ PERMITTED TO BE TAKEN AS 0.7 TIMES THE COMPONENT AND CLADDING(ASD) LOADS OBTAINED FROM TABLE R301.2(2). B. FOR CANTILEVER MEMBERS, L SHALL BE TAKEN AS TWICE THE LENGTH OF THE CANTILEVER. C.FOR ALUMINUM STRUCTURAL MEMBERS OR PANELS USED IN ROOFS OR WALLS OF SUNROOM ADDITIONS OR PATiO COVERS, NOT SUPPORTING EDGE OF GLASS OR SANDWICH PANELS, THE TOTAL LOAD DEFLECTION SHALL NOT EXCEED L/60. FOR CONTINUOUS ALUMINUM STRUCTURAL MEMBERS SUPPORTING EDGE OF GLASS, THE TOTAL LOAD DEFLECTION SHALL NOT EXCEED L/175 FOR EACH GLASS of FOR THE ENURE LENGTH OF THE MEMBER, WHICHEVER MORE STRINGENT. FOR STRAPPING SANDWICHCH PANELSLS USED IN ROOFS or WALLS OF SUNROOM ADDITIONS or PATIO COVERS, THE TOTAL LOAD DEFLECTION SHALL NOT EXCEED L/120. D.DEFLECTION FOR EXTERIOR WALL WITH INTERIOR GYPSUM BOARD FINISH SHALL BE UMITED TO AN ALLOWABLE DEFLECTION OF H/180. TA I L E.REFER TO SECTION R703.8.2. FU` E DOB NOW P' OJECT NUMBER BSCAN DRAWING No. SHEET No. e 10 OF 16 © E 2 n � C�a r(� 12"MAX. 12"MAX. 2-16d COMMON IG no mote than Z toCnaih shaT be k,sta+lid in each s de o+a rafter or calif* st when#astened to a Zx4 top pt C 0 N 6 U L' T A L V u 3 ••SIMPSON••HDUS NAILS C.4 6"O.C. g b' DEAD LOAD ASSUMPTIONS: ROOF ASSEMBLY DL = 10 s� ARCHITECT OF RECORD: 6"MIN. 6"MIN. FOR F 3. I ENOTx 6topp"ate. p DAVID CHAGNON,ARCHITECTURAL DESIGN PLLC OF sT1n3. O F LIVE d° -to-rdgehelets exceed 20,they sfati be adjusted as foPowv ROLOAD GROUND SNOW LOAD E-MAIL: DC_FILING@DCARCH-NY.COM 12 wall"eight 20 PSF 30 PSF 50 PSF 70 PSF "ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL IS ILLEGAL" 0 o #• 10° Plate to ALTERNATE a ~�' d+• ' .a °° ' ge Adjustment factor 00 F SPAN 12 24 36 12 2436 12(ft.) 1 36 1 12 1 24 36 COLLAR iIE a s 10 1.00 1.00 RAFTER SLOPE RAFTER NUMBER OF 16d COMMON NAILS or 40d BOX NAILS 0 0 °• O ".' ;, ,. 15' 2.15 1.25 SPACING PER HEEL JOINT CONNECTION 1,Z3,4,5,6 ALL STRAPPING TO BE 1 1/4' X 20 GAUGE STL �* _. r`r 10+ 1.40 1,50 (In. SIMPSON ° EQUIVALENT- CS20 ( COILED STRAP ) 4.1 t2) 4 7 to 4 8 12 s 11 i7 8 15 22 ALTERNATE AT RAFTER TO RIDGE CONNECTION. COLLAR PE EW�Q ''`''t .' 3:12 16 5 9 13 5 10 15 8 15 22 10 20 29 .; 19.2 6 11 16 6 12 18 9 18 27 12 24 35 FOR STRAP - 3 8d COMMON NAILS ®EA. END OF STRAP . ' Wails Resisting Uplift and Shears FOR NOTED COLLAR /CLG. 11E - 3 loci COMRIOF NAILS 9 EA. Exposure � 24 7 13 19 8 15 23 11 22 33 15 29 44 • `�° ' `° • '. .4 12 3 5 8 3 6 9 5 9 13 6 11 17 ptive Alternative to Table 3.d) CREATE! DESIGN/BUILD GROUP :•+ 16 4 7 10 4 8 12 6 11 17 8 15 22 .•'': ' :>. :'• 4:12 ARCHITECTURE-ENGINEERING-CONSTRUCTION 19.2 4 8 12 5 9 14 7 14 20 9 18 27 E-MAIL:NIMUNOZ CREATEDESIGNBUILDGROUP.COM AT RAFTER TO TOP PLATE TO STUD CONNECTION. •' ►. e• ' ; d east(mph) 24 5 10 15 6 12 17 9 17 25 11 22 33 @ e • 17 96 9S 100 10S 110 11S 120 130 140 ISO 16a 170 180 19s TEL:631-464-6668 FOR STRAP - 3 8d COMMON NAILS EN 12 3 4 6 3 5 7 4 7 10 5 9 14 FOR TOENAILING - 5 8d COMMON NAILS. 5/8" ANCHOR BOLT 0 32' O.C. FOR 1 STORY sB Tap&Bottom of 5:12 16 3 6 8 3 6 9 5 9 14 6 12 18 FOR C.J. TO R.R. - 11 i6d COMMON NAILS FOR 5 PITCH Panel Nailing 19.2 4 7 10 4 8 11 6 11 16 7 14 21 9 i6d COMMON PAILS ( FOR 8 ITCH ) 5/8' ANCHOR BOLT 0 32' O.C. FOR 2 STORY Recluirements 24 4 8 12 5 9 14 7 14 20 9 18 27 FOR C OF EA, PLATE TO PLATFORM ABOVE - 1 16d COMMON NAILS 016' O.C. 12 DIA.THREADED ROD EMBEDDED b/ 12 1/2"INTO CONCRETE W/•'SIMPSON"AT Maximum Roof Span(ftJ 1) MIN. 7' EMBEDMENT INTO CONCRETE (HIGH STRENOTII PRO>n ADI-IESW 3) RIItAs cif Nall 12 3 3 5 3 4 5 3 5 8 4 7 10 I FOR W/3° SQUARE WASHERS AND END NUT SETUP (mom S MTILENOTH ACP-MIC"wnl�sl�AT T Nails Spacing 7:12 9. 3 4 6 3 5 7 4 7 10 5 9 13 AT STUD TO FLOOR ASSEMBLY TO STUD CONNECTION to 19.2 3 5 7 3 6 8 4 8 12 5 10 15 ( ONLY APPLICABLE FOR TWO STORY CONFIGURATIONS ). 1 4 - - - - • 24 3 s 9 4 7 10 5 10 15 7 13 19 2) ANCHOR NOTED HEREIN ARE TO BE USED FOR HOLDOU�� CONNECTION 1st FLOOR tel 1 3 36 36 36 36 36 32 24 12 - OR REPLACED BY HOLD DOWNS FOR SHEARWALLS. 12 3 3 4 3 3 4 3 4 6 3 5 8 FOR STRAP - 3 8d COMMON NAILS @ EA. END OF STRAP ad 6 36 36 36 36 36 32 14 12 - - - 16 3 3 5 3 4 5 3 5 8 4 7 10 FOR C OF EA. PLATE TO PLATFORM ABOVE - 1 C OF EA. PLATE TO e z 3 4 36 36 36 36 36 36 36 36 36 32 28 20 16 12 9:12 PLATFORM BELOW- 1 16d COMMON NAILS®16�O.C. :;,. 3)1 - ANCHOR BOLT IS TO BE LOCATED BETWEEN 3 36 36 36 36 36 36 36 36 36 36 36 36 3z 2a 19.2 3 4 6 3 4 6 3 6 9 4 8 12 • 6' MIN. TO 12° MAX. FROM ENDS OR CORNERS. 11 24 3 5 7 3 5 8 4 S 11 5 10 15 AT STUD TO FLOOR ASSEMBLY TO SILL PLATE ( S ) CONNECTION. " ' "SIMPSON"HDU' 2-16d COMMON 1 6 - - - 12 3 3 3 3 3 3 3 3 5 3 4 6 BECKY SHEA DESIGN ' Fox FUIIalii O.C. sei 1 4 36 36 36 36 36 32 24 a 16 3 3 4 3 3 4 3 4 6 3 5 8 BECKY fitPtC�-IOR �OL7 SPECIFI rATION BECKYSHEA.COM :•:•,!:. I of sTur,. � 3 36 36 36 36 36 36 36 36 28 20 15 12 12:12 19.2 3 3 4 3 3 5 3 5 7 3 6 9 @ FOR STRAP - 3 8d COMMON NAILS 0 EA. END OF STRAP a 36 36 36 36 36 36 36 36 28 20 16 12 o° e S. 24 3 4 5 3 4 6 3 5 9 4 8 11 FOR C OF EA. PLATE TO PLATFORM 2 4 36 36 36 36 36 36 36 36 36 36 36 32 24 20 PLATFORM BELOW- 1 i6d COMMON NAILS 016' O.C. ° 3 36 36 36 36 36 35 36 36 36 36 36 36 36 32 1. -NAILING REQUIREMENTS SHALL BE PERMITTED TO BE REDUCED 25%IF NAILS ARE CLINCHED. REVISION DATE DESCRIPTION • 6 - - • - 2. -HEEL JOINT CONNECTION ARE NOT RETIR'-D WHEN THE RIDGE IS SUPPORTED BY A LOADBEARNG WALL AT STUD TO FLOOR ASSEMBLY TO SILL PLATE (S) CONNECTION xi 1 4 36 36 36 36 36 36 28 20 12 - - - HEADER,OR RIDGE BEAM DESIGNED TO RESST THE APPLIED LOADS. #1 10.24.24 P.E. COMMENTS SLAB ON GRADE APPLICATION. 3 36 36 36 35 36 36 36 36 36 24 20 16 12 •••tr M � 6 36 36 36 3b 36 36 3fi 36 36 24 20 16 12 - 3.- WHEN INTERME�DILA�TE SUPPORT OF THE RAFTER IS PROIDED BY VERTICAL STRUTS OR PURLINS TO A FOR STRAP - 3 Sd COMMON NAILS ®EA.END OF STRAP .. .,: : ++' :' PLYWOOD SHEATHING =.;:%::•, to z 5 4 36 36 36 36 36 36 36 36 36 36 36 3fi 32 24 TOABE REDI UCEo PROP�ORTIo�NAtiY�TOHiHE fIEEL �EIDUCTIIN�JNNCIN�REQUIREMENTS SHALL BE PERMITTED TO FOR C OF EA. PLATE TO PLATFORM BELOW- 1 16d COMMON NAILS 0 i6" O.C. SP 8dCOP/IMONNAILS „� '"..` 3 36 36 3fi 36 36 36 36 36 36 36 36 36 36 36 •r•.;• ,, �•� @ 6"Q.C.EDGE&FIELD ;•� SpecdDlDesignProtrislrurs 4.-EQUIVALENT CONNECTIONS ARE REQUIRED FOR CEILING JOIST TO CEILING JOIST LAP SPLICES. for Wind and for proper design and detailing of wood structural panels o° TABULATED HELL JOINT CONNECTION REQUIREMENTS DO NOT INCLUDE THE ADDITIONAL WEIGHT OF THE CANING BI-OCKING® °° ASSEMBLY. ENDWALL. d° 6. -TABULATED HEEL JOINT CONNECTION REQpU�IREMENTS ASSUME CEILING JOISTS OR RAFTER TIES ARE LOCATED AT THE BOTTOM OF THE ATTIC SPACE. I EN CEILING JOISTS OR RAFTER TIES ARE LOACTED HIGHER IN THE ATTIC SPACE NO ATTIC STORAGE IS ASSUMED AND THE TABULATED HEEL JOINT CONNECTION REQUIREMENTS CONSTRUCTION ADMINISTRATION BY: 3 TYPICAL. SECTION D E T A I L S HOLD DOWN (PRESCRIPTIVE ALTERNATIVE TO TABLE 3.4) STALL BE INCREASED BY THE FOLLOWING FACfMS: TO BE DETERMINED §SRR402.2 Concrete., 1/4* T T 1/3 1 S CLIENT: DATE: SCALE: 1/5 ALONZO FAMILY 12/24/22 AS SHOWN Concrete shall have a minimum specified compressive 2X4 CONTINUOUs 8}-�E,�RU�,a,LL SECS. DETAIL (T`I'P.� 1/6 1t 2 strength shown in table RR402.2(1)Concrete subject LATERAL BRACE SIMPSON• I-TDUS 1/10 i.1l 5 CLIENT/ADDRESS/SCOPE OF WORK AT 6'O.C. NOTE:ALL STRAPPING,ANCHORS,HOLI30WNS sA NOTE: LITERAL DEFLECTION OF THE RAFTER BELOW THE RAFTER TIES MAY EXCEED 3/4 INCH WIZEN RAFTER MI to weathering as indicated in table RR301.2(1) ADHESIVES TO HE 1NSTALLED AS PER ARE LOCATED ABOVE ONE-THIRD OF THE RIDGE HEIGHT,H , OR WHEN H I$GREATER THAN 2 FEET MID MANUFACTURERS SPECIFICATIONS. MAY REQUIRE ADDITIONAL CONSIDERATION. shall e air entrained as specified In table RR402.2. he maximun weight of fly ash,other pozzolangd,siligcia b HOLDOU1ri CONNECTION 2nd FLOOR PRIVATE fume,or slogthat is incluided in concrete mixtures for garage floor -TRUSS OR CEILING JOIST Rafter and/or Cellin;g Joist to Top Plate Lateral and slabs and for exterior porches, carpot slabs,and steps that will 2-IOd NAILS [8d YWOOD SHEATHING shear Connection Roquirements "" tMn8 L4Aa1Mn ins tet. S.M.n viann wa°P.,non I'm) be exposed to deicing chemicals shall not exceed the percentage YWOOONNAiLS 0 RESI®�__ "o.C.EDGE&FIELD Prescriptive Aitemative t 0 Table 3.4} OMM of the total weight of cementitiaLIS material used ° 1z 17 19 31 13 33 2a 1O i5 21 a7 53 40 g 1 12 i 6 NCE 9 30 lI 32 13 34 15 is 21 24 17 30 to produce concrete and testing there of shall comply with the . . 6 7 7 B 9 9 l0 11 24 16 se 2a P 9 P Y SOLID BLOCKING - = 3 5 s a 6 7 7 a 9 la a 14 is applicable standards listed in ACI 318. In GABLE END TRUSS 90 95 100 105 120 115 220 130 140 !SO i lx 12 2s 18 1i 34 17 40 47 54 62 75 79 PP ) a B lI 9 34 16 17 19 1a 26 27 tl 35 240 7 CEDARS ROAD addition to the cements permitted b ACI 318 cement complyingHOLD DOWN 1fi 4 8 9 70 10 11 12 24 26 18 22 1d 27 P Y 5 d COOLER NAILS 3 3 a 7 1 e 9 9 20 12 14 18 98 20 with ASTM C 1157 is permitted. AT 5 O.C. trap fmart°r 2oru i 12 27 30 33 37 40 44 48 56 6S 74 84 95 P GYP.BOARD I 6 a 14 15 17 19 20 22 24 28 33 37 42 48 Number of ad Common Nails or loci Sox Nails('foenatted) 19.2 C U TC H O G U E, N.Y. Ig11t ! i 9 la 13 12 34 13 16 39 22 LS 18 32 2X4 BLOCK NAILED TO EACH h 1 Required In Each Rafter and/or Ceiling Joist to Top Platt Connectl 3 3 7 a 9 9 10 11 12 14 17 I9 21 24 §RR403.1.4 Minimun depth.. BRACE WITH 4-10d NAILS a 12 24 41 46 55 ss 59 TD 61 +3 311 139 All exterior footings and foundation 24 6 6 17 1! 21 23 25 1E I0 33 27 41 55 4a 5 d COOLER Y 4 a 12 i3 id 14 17 19 m 2A 27 tl 35 40 systems shall extend below the frost line specified in Table RR301.2(1)all NAILS a7°o.c. 10-8d -� SHEARWALL SECS. DETAIL (T 1 'P- ! ' 9 10 31 IT 11 14 1! I! 21 t4 27 10 exterior footing shall be place at least 12 inches (305mm) bellow the 0 NAILS °` 6 1= 32 Is 39 43 47 53 56 66 76 37 99 u1 NEW RES I D E N C E undisturbed round. 11/4 X 20 G.A. i2 4 4 11 22 s3 is 16 17 u 22 26 2B 93 38 g STRAP �7 A��� 3 3 8 9 SO 1 32 13 U 17 19 22 25 28 NOTE: i 12 d) 47 L 57 83 68 14 17 1111 111, 112 149 a 6 21 24 z6 29 32 34 37 44 51 $8 66 75 §RR404.1 Concrete and masonry foundation walls. I-SHEATHING AS PART OF SHEARWALL SEGMENT(SW.S.) a 4 4 14 16 38 19 a 23 I5 29 34 39 44 so ENDWALL WHERE NOTED ON FLOOR PLAN,SHALL BE CONTINOUS FROM foundation walls shall be selected and constructed in accordace with 3 1 2 62 ls. 4 1 ! 2 26 33 3a Perlm4terfdgeZone ARCHITECTURAL SEAL: ARCHITECT OF RECORD: STUDS 6 2z 50 56 62 5S 71 82 a9 IaS 111 139 158 179 - DAVID CHAGNON, °ILL TO TOP PLATE OR ADEQUATELY BLOCKED AT JOINTS. 191 6 6 25 is 31 34 25 26 4S 33 61 70 79 so D ARCHITECTURAL the provisions of this section or in accordance with ACI 318 or ACI �i 8d COMMON NAILS a 6"O.C.EDGE&FIELD / 6` ® + A 37 1s 21 23 n 2a x1 3s 4I 4r s3 40 �E A� DESIGN PLLC INTERIOR ZONE 3 3 13 34 16 17 19 21 23 27 31 is 40 45 ��,� C E-MAIL: 530/ASCE 5/TMS 402. 2-HOLD DOWNS REQUIRED AT ALL 4 CORNERS OF STRUCTURE 4 11 43 70 78 $5 94 101 III III M 274 1" In / Fti C k DC FILING@DCARCH-NY.COM UNLESS OTHERWISE NOTED. 24 6 a 32 Is 39 43 47 51 56 66 76 a se 1u §RR404.4.6.1 GENERAL. PERIMETER ZONE 4 4 11 34 28 29 37 24 I7 44 s1 59 s4 75 `Z., $7 Reinforcing steel shall meet the requirements 8 CEILINGS BRACING CxABLE ENDWALL 3-SEE CONSTRUCTION DETAIL 2(NAILING AND STRAPPING) ® a ! 16 19 20 a 2a 26 B 33 3a 44 so s6 r Fastener Spacing &DETAIL 4(HOLD DOWN&CONN). uplift Load per Nall pbsl31 " of ASTM A 615, a 616, A 617 or 766 The minimun yield strength of GABLI'1.ALL GaMaEndwallRakeor n.) ._ reinforcing steel shall be 40,000 psi (Grade 40) (276 MPa). Vertical (EDGE ZONE). Rake Truss with up to 9" B ?8 31 35 39 u 44 so $9 6a 19 !! 300 * �)s U 1� RAsOverhang 4 _- 1! Il 13 2s 18 I! 0 39 AS $2 $9 41 +• I1, c and horizontal wall reinforcements shall be place no closer to the 3 14 16 la 19 27 13 25 10 3: A4 SD ALLOWABLE DEFLECTION OF STRUCTURAL MEMBERS 2" r-o"O.C. r-o°O.C. Ridge Connection Requirements for Wind °-' ,�. �- outside face of the wall than one-half the wall thickness. Steel TABLE R301.7 I I �' (Dead Load Assumptions'Roaf Assembly DIL 10psil Exposure E FaltenPrllp7Kt[apacityxTpb31 ' 04283g -y© reinforcement for foundation walls shall have concrete cover In - Sheathing Thickness llna 1/8 7/16 IS/32 10/32 23/32 O N L -ALTERATION OF THIS DOCUMENT N Frain Member SG 0.42 0-49 OA2 0.49 0.62 0.49 0.4I 0,49 0.42 0.49 accordance with AC 3184 STRUCTURAL MEMBER ALLO ° ° PPA1 !0 as 300 Les ISO 1IS 120 3!0 I40 ISO I40 170 1a0 1!3 Framing EXCEPT BYA LICENSED _ PROFESSpNAL IBILLEGAI` 0 0 o fl ad common' 70 41 N IXI 7 8 3 2 58 !6 LIGHT FIXTURE REQUIREMENTS: RAFTERS HAVING SLOPES GREATER THAN 3 / 12 WITH L / 180 �,,,,,, loci boat a4 I01 e2 -u:, a 110 77 Zia 71 30a NO FINISHED CEILING ATTACHED TO RAFTERS _I 2'-0"O.C. I 1/2"0 CARRIAGE BOLT(MTN.) i Z-0"O.C. n<, aa4�..aawarretxlas+canaKlaot°In"'" R Rso31 97 91 49 lw, 9g 11a o4 13g 9§ a3s W/WASHER&NUT(TYP.) 12 74 3A Sa 64 73 91 SG 134 169 2" 243 7B4 Sit 391 E5§ 02.1.3 Recessed lighting fixtures.When installed in the building envelope, INTERIOR WALLS & PARTITIONS H / 180 3t 37 S2 68 06 lei 121 141 102 226 274 3n 371 435 sn TYPICAL BOLL PATTERN FOR FLITCH PLATE 24. 54 ,.?1 n " °16d r IV 02 111 272 1" 44I, S68 454 93 recessed fixtures shall meet one of the following requirements: I. 32 a. I1 1CI 11! Lao 212 233 319 39S 410 -4a7 Set 654 925 FLOORS AND PLASTERED CEILJNGS L / 3fi0 8 3a �. _ es sl 139 ,ts ; Tao 2u 344 3Ia 395 ir! s6a 661 7B3 9zs 1. Type [Crated, manufactured with no penetrations between theinside of the 32 74 105 337 1)O 231 213 Sal 36B 462 Sal 130 75A era 10 p ALL OTHER STRUCTURAL MEMBERS L 240 34 e) tit 1st 1s2 131 x73 alfi 4D9 sat 616 730 r2 9az n recessed fixture andceiling cavity and sealed gaskeeted to prevent air leakage / NOTE: 12 76 is 45 55 6s 2l as III 119 168 1" 231 744 Wall Sheathing and Cladding AttachmentExposure 3t 15 41 60 » a7 102 111 150 I86 224 X Wt 354 4% Requirements for Wind i.oabdt3 B into the unconditioned space. EXTERIOR WALLS WITH PLASTER OR STUCCO FINISH L 360 u" -'sg '7s 'n 1L'9' `i2a°' "1u sal" 23z"' ''2aa "'7a1"° 'M 4A3`"' '_5 p / RIDGE PLATFORM FRAMING ONLY. 1. FOR GABLE ROOFS 10' TO 45' PITCHES. M $2 Al !! Ito 131 t53 276 3.16 271 3% 307 "1 512 4a_ ..._.°.....__...e�y. ,.,_. _....._ .. ......__....-_._. _ �...._.. . _,._.. _. w.._.„_•.. _°_,......... ._.............. ........_.-,__. __.. . .,.. 2. Type IC or non-IC rated, installed inside a sealed box 24 4) Al 304 128 153 179 206 TO 32% 392 VA 540 620 Ti wind Speed DOB EMPLOYEE STAMPS AND SIGNATURES yp EXTERIOR WALLS - WIND LOADS o WITH BRITTLE FINISHES L / 240 2. SEE FASTENING SCHEDULE A FOR NAILING IN EA. ZONE. 3I2 49 9a 319 14b 1'14 KA 233 301 its "I 530 611 109 a: 3-second gait constructed from a minimun 0.5-inch-thick (12.7mm) gypsum wallboard 34 is IDS b4 164 1% 730 264 133 413 SO4 596 6" 797 IN Imphi 90 95 100 105 110 115 220 130 la0 is0 160 170 180 195 or constructed from a preformed polymeric vapor barrier,or other EXTERIOR WALLS - WIND LOADS a WITH FLEXIBLE FINISHES L / 120 s1 20 27 35 A3 51 60 69 a8 109 "1 3% IS2 2U9 V 3 • ±zRR303.3 BatT:Irpom water closet COm pertinent 34 26 Ar 36 46 ,µ,37 .6e a9 92 Ila 146 176 20! 242 279 3: air-tight assembly, manufactured for this purpose, while maintaining NOTE: L - SPAN LENGTH. H - SPAN HEIGHT and other similar rooms shall be provided 20 ""'$1" 4s""' sa'" n iDa" 11i" "147' 191" '`220 260" `tiDl ' 'sae' `as required clearances of not legs than 0.5 inch (12.7) from with aggregate glazing area to windows ' 74 40 54 a - 8S 102 114 131 17T: "219 � 94 111 YA 419 SI ST'RUt:TURALSHEATHING #', 24 a8 6a 81 .99 in 139 '161 M 255 � 36a 424 vita sC E F E F l: F E F E F E F E F E F E F E F E FIE F E F E F a = THE WIND LOAD SHALL BE PERMITTED TO of not less than 3 square feet (0.279 m2), Stud that 3 inches (76mm) from insulation material. one-half of which must be O enable. 32 60 72 0 122 236 iLS9n 207 236 its 396 am "S 627 6; L =I BE TAKEN AS 0.7 TIMES THE COMPONENT AND p 36 w 4I Ia 12s ul 17! 2D7 36s Ira 396 am 54s 6n 7�Loca:ion Maximum Nail Spacing for Rd Common Nails or Tod Box Nabs(inches,e,o.)' CLADDING LOADS FOR THE PURPOSE OF THE 12 20 26 13 40 4t Ss 63 ai 99 119 141 I&A' laic 2 (inches,a.c.I 3. Type IC rated in accordance with ASTM E 283 no more than 2.0 cubic DETERMINING DEFLECTION LIMITS HEREIN. I4 2, 35 4a 34 a3 74 Is 1N 113 159 In 233 250 IK 12 6 12 s 12 ti iz fi 12 s 12 6 72 6 12 6 12 6 12 6 12 6 12 6 12 6 12 6 12 t EXCEPTION: The glazed areas shall not be i' 'i1""" 'au`' "`55 '" 79'" "3i iai' "135 f6a `"199' i35" "273 tl3`" _*",Zone IB 6 12 6 12 IS 32 6 12 6 12 6 12 6 12 6 12 6 12 6 12 6 12. 6 12 6 12 6 12 feet per minute (cfm) (0.944 L/s) air movement from the conditioned required where artificial light and a mechanical 24 4a sl 6a ad' 9s 111 n27 162 199 239 " 2a2 31r 376 a; 24 6 12 6 12 6 12 fi 12 6 12' 6 S2 6 12 6 12 6 12 6 12 6 12 s 6 6 6 6 6 ventilation system area provided. the rnenimum 11 -23 47 63 71 94 III 'In -141 IN' 111 "279 - 3" 392 ` 438 S space to the ceiling cavity.The lighting fixture shall be tested at ventilation rates tahall be 5O Cfm(h23.s1/s) for 32 53 10 3a 107 121 M 149 215 265 319 376 436 501 M 12 6 12 6 12 li 12 6 12 6 12 6 12 s 12 6 32 6 12 6 32 6112 6 iz 6 12 6 12 1.57 psi (75 Pa) pressure difference and shall be labeled. TOP PLATE SPLICE REQUIREMENTS intermittent ventilation air from t e space 40 79 99 lit 143 1t4 290 242 298 158 423 01 slit 4tdgeZone 16 6 12 6 12 1i 12 6 12 6 12 6 12 6 12 6 12 6 12 6 12 6 12 6 12 6 12 6 6 FOR WIND EXPOSURES B&C ATTIC SPACE. shall be exhausted direct/ t0 the outside. I2 27 31 Ir 43 49 S$ 42 76 94 122 132 253 175 2 y 36 36 43 so s7 65 73 zz 102 125 t49 176 204 233 x 24 6 12 6 12 fi 12 6 12 6 12 6 12 6 1216 12 6 12 6 12 6 6 6 6 6 6 6 6 ONE STORY SLAB ON GRADE r. - 20> 4s" s3 i2" ""7z"' "li '93 Jai Yea is6 lag " "''22a 254"" "291' k BOARD SHEATHING or LAP SIDING 24 3 54 6+ n a 98 Up 123 153 187 224 - 263 305 350 4; BUILDING MIN.SPLICE §RR303.7 and R303.8 Stairway 11Adi3ridt13zbt0n. g: 28 ! 62 74 - 37 'lea 111 129 144 -1" 213 261 307 r% 409 4+ng 6i2e RafterfTrussSpacing TABLE402.2 and exterior stairways shall be provided with 31 71 as 99 115 130 147 264 204 250 199 352 401 466 SI MIn1mum Number ofSd Common Nails or10d Box Nails DIMENSION LENGTH 34 30 96 112 129 147 165 In 2" 281 336 3% 458 52S aS (inches,D.C.J TOP PLATE SPLICE LENGTH a means to illuminate the stairs, including �„D„r.w,. r,wltKo4•,"tarp,ofie.„,nr��awaIolar,.n,4,�„lu<4,rc.•,maesr�,°1rv,�1,•�r4mrn Persupporc MINIMUM SPECIED COMPRESSIVE STRENGHT OF CONCRETE the landings and treads. Interior starwoys 12'.0" 2'-0" BLOCKING 2 BAYS shall be capable of illuminating tread and ^• r^ ua'=oasra4�Iwmuarhm«a rnr 4da:> ardr4dw"ad6Ps•to6410o�'-sash. sheathing 12-24 2 2 2 z 2 z 2 2 2 2 2 2 z z SHEET TITLE MINIMUN SPECIFIED 16'-0" 3'-0" BACK(�4'-0"O.C. landings to levels not less than 10 foot rt4.N4��sa WirdWaU nil ltesta"LoW40I1j.r.»46"OVINMr�«.�,sQAr a"It,plytneUWlatedv4luesbv the appropdate lrsheathi 12.24 3 3 3 3 3 3 3 9 3 3 3 3 3 3 TYPE OR LOCATIONS OF 20'•0° 4'.0" candles (108 Ix) measured at the center of '"° -� COMPRESSIVE STRENGTH A fC 24t- - treads and landings. Exterior stairways IwP4 domsp.&V11^-) 3300 i�s3 y90 a4 a ease oo CONCRETE CONSTRUCTION 28'-0" 5'-0" a shall be provided with on artificial light „a,,,, ,�,,, �,,,,,aa•�M"gt6a„dL>,eapa,,. Weahering potentialb 32'-0" 6'-0" source located in the inmediate vicinity 0' `°""«` �"`°°°"'°"1a4tO"""`"`M"•'""'` ,e.`a`°"r< 36'-0" T-0" 3 of the top landing of the stairway. WITH FINISHED CEILING ATTACHED TO RAFTERS 40'•0" 8'-0" SECOND FLOOR. Exterior stairway providing access INTERIOR WALLS AND PARTITIONS H/180 50'-0' ]0'-0' from the outside grade level shall be provided with an artificial light source located in the FLOORS L/360 ®� Basement wall, foundations and other 60'-0" 12'-0" w y g 2,500 2,500 2,500c 70"-0" 14'-0" immediate vicinity of the bottom landing CEILINGS WITH BRITTLE FINISHES (INCLUDING of the stairway. PLASTER and STUCCO L/360 concrete not exposed to the weather So'-o° 16'-0" ) Basement Slabs and interior slabs On EXCEPTION: An artificial light source is not required CEILINGS WITH FLEXIBLE FINISHES (INCLUDING (. 240 at the top and bottom landing, provided an GYPSUM BOARD) / grade, except garage floor slabs 2,500 2,500 2,500c BLOCKING 2BAYS artificial light source is located directly over ALL OTHER STRUCTURAL MEMBERS L/24o r- I I I L BACK(r�,4'-0"O.C. each stairway section. TOP PLATE SPLICE REQUIREMENTS EXTERIOR WALLS - WIND LOADS 0WiTH PLASTER H/360 Basement wail, foundation wall, exterior wall FOR WIND EXPOSURES B&C OR STUCCO FINISH and other vertical concrete work exposed 2,500 3,000d 3,000d ALL OTHER CASES 1 - TABULATED SPLICE LENGTHS ASSUME TOP PLATE- EXTERIOR WALLS - WIND LOADS °WITH OTHER BRITTLE FINISHES H/240 to the weather. ' TO - TOP PLATE CONNECTIONS USING 2 - 16D NAILS PER FT. DOB NOW PIROJECTNUMBER Porches, carport slabs and steps FOR SHORTER SPUCE LENGTHS, THE NAILS SPACING EXTERIOR WALLS - WIND LOADS °WITH FLEXIBLE FINISHES H/1200 BUILDING MIN.SPLICESHALL BE FIRST FLOOR. LINTELS SUPPORTING MASONRY VENEER WALLS a L/600 p p DIMENSION LENGTH NUMBER OF NAILS.D IN ORDER TO PROVIDE EQUIVALENT BscAN exposed to the weather,and garage 2,500 3,000d,e 3,500d,e to floor slabs. 12'-0" 3'-0" 2 - TABULATED SPLICE LENGTH ASSUME A BUILDING NOTE: L= SPAN LENGTH, H = SPAN HEIGHT 16'-0" 4'-0" LOCATED IN EXPOSURE (B). A.FOR THE PURPOSE OF THE DETERMINING DEFLECTION LIMITS HEREIN, THE WIND LOAD SHALL BE PERMITTED TO BE TAKEN AS 0.7 71MES THE COMPONENT AND CLADDING(ASD) LOADS OBTAINED FROM For S:I1 pound per square inch=6.$95 KPA. 20'-0" 5'-0" TABLE R3D1.2(2). 24'-0" 6'-0° 3 - TABULATED SPLICE LENGTHS ARE BASED ON S FT. a.At 28 day psi. 28'-0" T-0" WALL HEAIGHTS FOR OTHER WALL HEIGHTS, (H) BLOCKING 2 BAYS B. FOR CANTILEVER MEMBERS, L SHALL BE TAKEN AS TWICE THE LENGTH OF THE CANTILEVER. b.See Table RR301.2 1 for weathering potential. THE TABULATED UNIT LATERAL LOADS SHALL BE MULTIPLIED C.oR PAALUMINUM TIO COVERS, NOT STRUCTURAL SUP MEMBERS OR PANELSOF U ED IN ROOFS PEA WALLS OF TOTALOLOA ADDITIONS ( ) 9 P 32'-0" 8 -0' BACK(r7 4'-0 O.C. C. Concrete in these locations that may be subject to freezing and BY DEFLECTION SHALL NOT EXCEED L/60. FOR CONTINUOUS ALUMINUM STRUCTURAL MEMBERS 40'.01' 11'-0" SUPPORTING EDGE OF GLASS, THE TOTAL LOAD DEFLECTION SHALL NOT EXCEED L/175 FOR EACH thawing during construction shall be air-entrained in accordance 50'- „ 4 - TOP PLATES SHALL BE MINIMUM OF STUD GRADE MATERIAL ry ACC I ITC wt I yen Cr1a TLC minor 1 mim'nu rw TLC L2CL3aCa uxnr 3Cu[D IC Larmc- vmikir•CLm rno DRAWING No. SHEET No. with footnote d. 60'.o" 16'-o" 9 SPLICING OF TOP PLATE BLOCiCINCs AT ENDWALL 11 d.Concrete shall be air entrained.Totai air content (percent b volume 70"-0" 19'-0" A 9 OF 16 LOW-RISE RESIDENTIAL COMPLIANCE PATH SECTION M1601 .4 - DUCT INSTALLATION SECTION R402.4-AIR LEAKAGE. (MANDATORY) SECTION COMPLIANCE PATH M1601.4.1 JOINTS, SEAMS AND CONNECTIONS. LONGITUDINAL AND TRANSVERSE JOINTS, SEAMS AND CONNECTIONS IN METALLIC R402.4 AIR LEAKAGE (MANDATORY). THE BUILDING THERMAL ENVELOPE SHALL BE CONSTRUCTED TO LIMIT AIR LEAKAGE IN ACCORDANCE WITH THE REQUIREMENTS OF SECTIONS R402.4,1 AND NONMETALLIC DUCTS SHALL BE CONSTRUCTED AS SPECIFIED IN SMACNA HVAC DUCT CONSTRUCTION STANDARDS-METAL AND THROUGH R402.4.4. ARCHITECT OF RECORD: DAVID CHAGNON,ARCHITECTURAL DESIGN PLLC 402 (R402) BUILDING FLEXIBLE AND NAIMA FIBROUS GLASS DUCT CONSTRUCTION STANDARDS. JOINTS, LONGITUDINAL AND TRANSVERSE SEAMS,AND R402.4.1 BUILDING THERMAL ENVELOPE. THE BUILDING THERMAL ENVELOPE SHALL COMPLY WITH SECTIONS R402.4.1.1 AND R402.4.1.2.THE SEALING METHODS BETWEEN DISSIMILAR E-MAIL; DC -NY.COIM MANDATORY + TOTAL UA ALTERNATIVE CONNECTIONS IN DUCTWORK SHALL BE SECURELY FASTENED AND SEALED WITH WELDS, GASKETS, MASTICS (ADHESIVES), MASTICPLUS- ALTERATION OF THIS DOCUMENT EXCEPT BYALICENSED PROFESSIONAL IS ILLEGAL" THERMAL ENVELOPE MATERIALS SHALL FOR DIFFERENTIAL EXPANSION AND CONTRACTION. EMBEDDED-FABRIC SYSTEMS, LIQUID SEALANTS OR TAPES. TAPES AND MASTICS USED TO SEAL FIBROUS GLASS DUCTWORK SHALL R402.4.1.1 INSTALLATION. THE COMPONENTS OF THE BUILDING THERMAL ENVELOPE AS LISTED IN TABLE R402.4.1.1 SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S SECTION R403.3 - SYSTEMS (MANDATORY) BE LISTED AND LABELED IN ACCORDANCE WITH UL 181A AND SHALL BE MARKED "181A-P" FOR PRESSURE-SENSITIVE TAPE, "181 AM" INSTRUCTIONS AND THE CRITERIA LISTED IN TA13LE R402.4.1.1,AS APPLICABLE TO THE METHOD OF CONSTRUCTION. WHERE REQUIRED BY THE CODE OFFICIAL,AN APPROVED THIRD PARTY DUCTS AND AIR HANDLERS SHALL BE IN ACCORDANCE WITH SECTIONS R403.3.1 THROUGH FOR MASTIC OR"181 A-H" FOR HEAT-SENSITIVE TAPE. SHALL INSPECT ALL COMPONENTS AND VERIFY COMPLIANCE. R403.3.5. DUCT CONNECTIONS TO FLANGES OF AIR DISTRIBUTION SYSTEM EQUIPMENT SHALL BE SEALED AND MECHANICALLY FASTENED. v - R402.4.1.2 TESTING. THE BUILDING OR DWELLING UNIT SHALL BE TESTED AND VERIFIED AS HAVING AN AIR LEAKAGE RATE OF NOT EXCEEDING 5 AIR CHANGES PER HOUR. TESTING SHALL BE R403.1 CONTROLS(MANDATORY). CRIMP JOINTS FOR ROUND METALLIC DUCTS SHALT_HAVE A CONTACT LAP OF NOT LESS THAN 1 INCH (25 MM)AND SHALL BE CONDUCTED WITH A BLOWER DOOR AT A PRESSURE OF 0.2 INCHES W.G. (50 PASCALS).WHERE REQUIRED BY THE CODE OFFICIAL, TESTING SHALL BE CONDUCTED BY AN APPROVED THIRD MECHANICALLY FASTENED BY MEANS OF NOT LESS THAN THREE SHEET-METAL SCREWS OR RIVETS EQUALLY SPACED AROUND THE JOINT. PARTY.A WRITTEN REPORT OF THE RESULTS OF THE TEST SHALL BE SIGNED BY THE PARTY CONDUCTING THE TEST AND PROVIDED TO THE CODE OFFICIAL. TESTING SHALL BE PERFORMED AT LEAST ONE THERMOSTAT SHALL BE PROVIDED FOR EACH SEPARATE HEATING AND CREATE! DESIGN/BUILD GROUP COOLING SYSTEM. TAPES AND MASTICS USED TO SEAL METALLIC AND NONMETALLIC FLEXIBLE AIR DUCTS AND FLEXIBLE AIR CONNECTORS SHALL COMPLY AT ANY TIME AFTER CREATION OF ALL PENETRATIONS OF THE BUILDING THERMAL ENVELOPE. ONCE VISUAL INSPECTION HAS CONFIRMED SEALING (SEE TABLE R402.4.1.1), OPERABLE ARCHITECTURE-ENGINEERING-CONSTRUCTION WINDOWS AND DOORS MANUFACTURED BY SMALL BUSINESS SHALL BE PERMITTED TO BE SEALED OFF AT THE FRAME PRIOR TO THE TEST. E-MAIL:MMUNOZ@CREATEDESIGNBUILDGROUP.COM R403.1.1 PROGRAMMABLE THERMOSTAT. WITH UL 181B AND SHALL BE MARKED"181 B-FX" FOR PRESSURE-SENSITIVE TAPE OR"l81 BM" FOR MASTIC. FITTINGS USED IN TEL:631-464-6668 THE THERMOSTAT CONTROLLING THE PRIMARY HEATING OR COOLING SYSTEM OF THE COMBINATION WITH FLEXIBLE AIR DUCTS AND AIR CONNECTORS SHALL HAVE A FLANGE LENGTH OF NOT LESS THAN 2 INCHES(51 MM) FOR DURING TESTING: DWELLING UNIT SHALL BE CAPABLE OF CONTROLLING THE HEATING AND COOLING SYSTEM ON CONNECTION OF THE FLEXIBLE DUCT. FLEXIBLE DUCT INNER CORES SHALL BE INSTALLED NOT LESS THAN 1"(25MM)ONTO THE FITTING PRIOR 1. EXTERIOR WINDOWS AND DOORS, FIREPLACE AND STOVE DOORS SHALL BE CLOSED, BUT NOT SEALED, BEYOND THE INTENDED WEATHERSTRIPPING OR OTHER INFILTRATION A DAILY SCHEDULE TO MAINTAIN DIFFERENT TEMPERATURE SET POINTS AT DIFFERENT TIMES TO TAPING AND APPLICATION OF THE MECHANICAL FASTENER. MASTIC SHALL BE APPLIED IN ACCORDANCE WITH THE MASTIC CONTROL MEASURES; OF THE DAY. THIS THERMOSTAT SHALL INCLUDE THE CAPABILITY TO SET BACK OR MANUFACTURER'S INSTALLATION INSTRUCTIONS PRIOR TO PULLING THE INNER CORE ONTO THE FITTING AND APPLYING THE, MECHANICAL 2. DAMPERS INCLUDING EXHAUST, INTAKE, MAKEUP AIR, BACKDRAFT AND FLUE DAMPERS SHALL BE CLOSED, BUT NOT SEALED BEYOND INTENDED INFILTRATION CONTROL MEASURES TEMPORARILY OPERATE THE SYSTEM TO MAINTAIN ZONE TEMPERATURES DOWN TO 55D F FASTENER. NONMETALLIC MECHANICAL FASTENERS FOR USE WITH FLEXIBLE NONMETALLIC AIR DUCTS SHALL COMPLY WITH UL 181 B AND (13DC)OR UP TO 85GF(29DC).THE THERMOSTAT SHALL INITIALLY BE PROGRAMMED BY THE SHALL BE MARKED 181 B-C.WHERE NONMETALLIC MECHANICAL FASTENERS ARE USED,THE FITTINGS SHALL BE BEADED. THE 3. INTERIOR DOORS, IF INSTALLED AT THE TIME OF THE TEST, SHALL BE OPEN,ACCESS HATCHES TO CONDITIONED CRAWL SPACES AND CONDITIONED ATTICS SHALL BE OPEN; MANUFACTURER WITH A HEATING TEMPERATURE SET POINT NO HIGHER THAN 70DF(21 GC)AND A COOLING TEMPERATURE SETT POINT NO LOWER THAN 78GF 26GC . INSULATION AND OUTER VAPOR BARRIER OF FLEXIBLE DUCTS SHALL BE SEALED TO THE: FITTING USING 2 WRAPS OF APPROVED DUCT TAPE OR 4. EXTERIOR OPENINGS FOR CONTINUOUS VENTILATION SYSTEMS AND HEAT RECOVERY VENTILATORS SHALL BE CLOSED AND SEALED; BECKY DESIGN ( ) BECKY@BECKYCKYSHEA.COM 11403.1.2 HEAT PUMP SUPPLEMENTARY HEAT(MANDATORY). A MECHANICAL FASTENER IN PLACE OF, OR IN CONJUNCTION WITH, THE TAPE. 5. HEATING AND COOLING SYSTEMS, IF INSTALLED AT THE TIME OF THE TEST, SHALL BE TURNED OFF;AND CLOSURE SYSTEMS USED TO SEAL ALL DUCTWORK:SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS' INSTRUCTIONS. REVISION DATE DESCRIPTION HEAT PUMPS HAVING SUPPLEMENTARY ELECTRIC-RESISTANCE HEAT SHALL. HAVE CONTROLS 6. SUPPLY AND RETURN REGISTERS, IF INSTALLED AT THE TIME OF THE TEST, SHALL BE FULLY OPEN. #1 10.24.24 P.E. COMMENTS THAT, EXCEPT DURING DEFROST, PREVENT SUPPLEMENTAL HEAT OPERATION WHEN THE EXCEPTIONS: EXCEPTIONSA.ADDITIONS LESS THAN 500 SQUARE FEET OF CONDITIONED FLOOR AREA.2.ADDITIONS TESTED WITH THE EXISTING HOME HAVING A COMBINED MAXIMUM AIR LEAKAGE RATE HEAT PUMP COMPRESSOR CAN MEET THE HEATING LOAD. 1. SPRAY POLYURETHANE FOAM SHALL BE PERMITTED TO BE APPLIED WITHOUT ADDITIONAL JOINT SEALS. MANDATOR SCREWS 7 AIR CHANGES PER HOUR.TO QUALIFY FOR THIS EXCEPTION,THE DATE OF CONSTRUCTION OF THE EXISTING HOUSE MUST BE PRIOR TO THE 2009 WASHINGTON STATE ENERGY RR403.3.2 SEALING (MANDATORY). 2. WHERE A DUCT CONNECTION IS MADE THAT IS PARTIALLY INACCESSIBLE, THREE SCREWS OR RIVETS SHALL BE CODE.R402.4.2 FIREPLACES. NEW WOOD-BURNING FIREPLACES SHALL HAVE TIGHT-FITTING FLUE DAMPERS OR DOORS,AND OUTDOOR COMBUSTION AIR. WHEN USING TIGHT-FITTING DOORS DUCTS,AIR HANDLERS AND FILTER BOXES SHALL BE SEALED. JOINTS AND SEAMS SHALL EQUALLY SPACED ON THE EXPOSED PORTION OF THE JOINT SO AS TO PREVENT A HINGE EFFECT. ON FACTORY-BUILT FIREPLACES LISTED AND LABELED IN ACCORDANCE WITH UL 127, THE DOORS SHALL BE TESTED AND LISTED FOR THE FIREPLACE.WHERE USING TIGHT-FITTING DOORS ON COMPLY WITH EITHER THE INTERNATIONAL MECHANICAL CODE OR INTERNATIONAL 3. FOR DUCTS HAVING A STATIC PRESSURE CLASSIFICATION OF LESS THAN 2 INCHES OF WATER COLUMN (500 PA), MASONRY'FIREPLACES, THE DOORS SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 907. RESIDENTIAL CODE,AS APPLICABLE. CONSTRUCTION ADMINISTRATION BY: ADDITIONAL CLOSURE SYSTEMS SHALL NOT BE REQUIRED FOR CONTINUOUSLY WELDED JOINTS AND SEAMS AND R402.4.3 AIR LEAKAGE OF FENESTRATION.WINDOWS, SKYLIGHTS AND SLIDING GLASS DOORS SHALL HAVE AN AIR INFILTRATION RATE OF NO MORE THAN 0.3 CFM PER SQUARE FOOT(1.5 TO BE DETERMINED EXCEPTIONS: LOCKING-TYPE JOINTS AND SEAMS OF OTHER THAN THE SNAP-LOCK AND BUTTON-LOCK TYPES. US/M2),AND SWINGING DOORS NO MORE THAN 0.5 CFM PER SQUARE FOOT(2.6 US/M2),WHEN TESTED ACCORDING TO NFRC 400 OR AAMA/WDMA/CSA 101/I.S.2/A440 BY AN ACCREDITED, 1.AIR-IMPERMEABLE SPRAY FOAM PRODUCTS SHALL BE PERMITTED TO BE APPLIED WITHOUT M1601.4.3.1 SUPPORT FLEXIBLE AIR DUCTS AND AIR CONNECTORS SHALL BE SUPPORTED AT INTERVALS NOT TO EXCEED 4 FEET INDEPENDENT LABORATORY AND LISTED AND LABELED BY THE MANUFACTURER. CLIENT: DATE: SCALE: ADDITIONAL JOINT SEALS. ALONZO FAMILY 12/24/22 AS SHOWN (1219MM)WHERE INSTALLED HORIZONTALLY AND 6 FEET(1829MM)WHERE INSTALLED AS VERTICAL RISERS AND SHALL BE INSTALLED IN EXCEPTIONS:1. FIELD-FABRICATED FENESTRATION PRODUCTS (WINDOWS, SKYLIGHTS AND DOORS).2. CUSTOM EXTERIOR FENESTRATION PRODUCTS MANUFACTURED BY A SMALL BUSINESS 2. ACCORDANCE:WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS AND THE ADC FLEXIBLE DUCT PERFORMANCE& INSTALLATION PROVIDED THEY MEET THE APPLICABLE PROVISIONS OF CHAPTER 24 OF THE INTERNATIONAL BUILDING CODE. ONCE VISUAL INSPECTION HAS CONFIRMED THE PRESENCE OF A GASKET CLIENT/ADDRESS/SCOPE OF WORK W FOR DUCTS HAVING A STATIC PRESSURE CLASSIFICATION LESS THAN 2 INCHES STANDARDS. SUPPORTS SHALL BE NOT LESS THAN 1.5 INCHES (38MM IN WIDTH AND THE SAG BETWEEN SUPPORTS SHALL NOT EXCEED OPERABLE WINDOWS AND DOORS MANUFACTURED BY SMALL BUSINESS SHALL BE PERMITTED TO BE SEALED OFF AT THE, FRAME PRIOR TO THE TEST.R402.4.4 COMBUSTION AIR OPENINGS. IN WATER COLUMN (500 PA),ADDITIONAL CLOSURE SYSTEMS SHALL NOT BE REQUIRED FOR ) CLIMATE ZONES 3 THROUGH 8, WHERE OPEN COMBUSTION AIR DUCTS PROVIDE COMBUSTION AIR TO OPEN COMBUSTION, SPACE CONDITIONING FUEL BURNING APPLIANCES, THE CONTINUOUSLY WELDED JOINTS AND SEAMS,AND LOCKING-TYPE JOINTS AND SEAMS OF 1/2" (13MM)PER FOOT OF DUCT LENGTH BETWEEN SUPPORTS. PRIVATE APPLIANCES AND COMBUSTION AIR OPENINGS :SHALL BE LOCATED OUTSIDE OF THE BUILDING THERMAL ENVELOPE, OR ENCLOSED IN A ROOM ISOLATED FROM INSIDE THE THERMAL OTHER THAN THE SNAP-LOCK AND BUTTON-LOCK TYPES.R1403.3.2.1 SEALED AIR HANDLER. SECTION R403.4 MECHANICAL SYSTEM PIPING INSULATION_(MANDATORY). ENVELOPE, SUCH ROOMS SHALL BE SEALED AND INSULATED IN ACCORDANCE WITH THE ENVELOPE REQUIREMENTS OF TABLE R402.1.1,WHERE THE WALLS, FLOORS AND CEILINGS SHALL R E S I D NE C MEET THE MINIMUM OF THE BELOW-GRADE WALL R-VALUE REQUIREMENT. THE DOOR INTO THE ROOM SHALL BE FULLY GASKETED AND ANY WATER LINES AND DUCTS IN THE ROOM Ell, AIR HANDLERS SHALL HAVE A MANUFACTURES DESIGNATION FOR AN AIR LEAKAGE OF NO MECHANICAL SYSTEM PIPING CAPABLE OF CARRYING FLUIDS ABOVE 1050F(41 DC)OR BELOW 55GF (13DC)SHALL BE INSULATED TO A MINIMUM OF R-3. INSULATED IN ACCORDANCE WITH SECTION R403.THE COMBUSTION AIR DUCT SHALL.BE INSULATED WHERE IT PASSES THROUGH CONDITIONED SPACE TO A MINIMUM OF R-8. MORE THAN 2 PERCENT OF THE DESIGN AIR FLOW RATE WHEN TESTED IN ACCORDANCE WITH R403.4.1 PROTECTION OF PIPING INSULATION. EXCEPTIONS:1. DIRECT VENT APPLIANCES WITH BOTH INTAKE AND EXHAUST PIPES INSTALLED CONTINUOUS TO THE OUT SIDE.2. FIREPLACES AND STOVES COMPLYING WITH SECTION R402.4.2 ASHRAE 193. PIPING INSULATION EXPOSED TO WEATHER SHALL BE PROTECTED FROM DAMAGE, INCLUDING THAT CAUSED BY SUNLIGHT, MOISTURE, EQUIPMENT AND SECTION R1006 OF THE INTERNATIONAL RESIDENTIAL CODE.R402.4.5 RECESSED LIGHTING. RECESSED LUMINAIRES INSTALLED IN THE BUILDING THERMAL ENVELOPE SHALL BE TYPE CEDARS ROAD R,403.3.3 DUCT TESTING (MANDATORY). MAINTENANCE AND WIND,AND SHALL PROVIDE SHIELDING FROM SOLAR RADIATION THAT CAN CAUSE DEGRADATION OF THE MATERIAL.ADHESIVE IC-RATED AND CERTIFIED UNDER ASTM E283 AS HAVING AN AIR LEAKAGE RATE NOT MORE THAN 2.0 CFM (0.944 US)WHEN TESTED AT A 1.57 PSF (75 PA) PRESSURE DIFFERENTIAL AND SHALL CUTCHOG U E, N.Y. DUCTS SHALL BE PRESSURE TESTED TO DETERMINE AIR LEAKAGE BY ONE OF THE FOLLOWING TAPE SHALL NOT BE PERMITTED. HAVE A LABEL ATTACHED SHOWING COMPLIANCE WITH THIS TEST METHOD.ALL RECESSED LUMINAIRES SHALL BE SEALED WITH A GASKET OR CAULK BETWEEN THE HOUSING AND THE METHODS: INTERIOR WALL OR CEILING COVERING - NEW RESIDENCE 1. ROUGH-IN TEST: TOTAL LEAKAGE SHALL BE MEASURED WITH A PRESSURE DIFFERENTIAL - OF 0.1 INCH W.G. (25 PA)ACROSS THE SYSTEM, INCLUDING THE MANUFACTURERS AIR HANDLER ENCLOSURE IF INSTALLED AT THE TIME OF THE TEST.ALL REGISTERS SHALL BE }--�` -- - - ,. .; a yti� ,-^'�tl I .��. 3 _ r .r r �s o sglf�� ARCHITECTURAL SEAL: ARCHITECT OF RECORD: TAPED OR OTHERWISE SEALED DURING THE TEST. a � - �ui[t-°� vI �syk. r. DAVID ARCHITECTURAL' 1� r�"t �� 1t� I �ill M : rr Epq E-MAIL: „C�R RC DESIGN PLLC r LL - '- \� Ro r k�1 ` DC FILING@DCARCH-NY.COM 2. POSTCONSTRUCTION TEST: TOTAL LEAKAGE SHALL BE MEASURED WITH A PRESSURE .. .A _. c� P� , .._ DIFFERENTIAL OF 0.1 INCH W.G. 25 PA ACROSS THE ENTIRE SYSTEM, INCLUDING THE �' 1 JII` I tO box ,,,,. MANUFACTURERS AIR HANDLER(ENCLOSURE. REGISTERS SHALL BE TAPED OR OTHERWISE ` -� ''~ Ceiling drywall tapped yet `,V ., ="� * *- o SEALED DURING THE TEST. „� ri � H �� 14 %vall 4 . � R II_ EXCEPTION:A DUCT AIR LEAKAGE TEST SHALL NOT BE REQUIRED WHERE THE DUCTS AND AIR �" � � �-�` -�� �'� �a.' ,� � � t. � -� �' -t HANDLERS ARE LOCATED ENTIRELY WITHIN THE BUILDING THERMAL ENVELOPE. od �F�,ryor+� �j caulked, 7(y y �yj�.� p� ^� gy p "-� �` a� ""mC` FN "ALTERATION OF THIS DOCUMENT h,P� LJ{,1,i.xi.*$S.� L4JVY} W�'C1Le FR A�'9.. ', r, µ 4 ¢• ,�'.�" _ !A i .. dnL p ,,,-, �{'.ry' !• 6 s - EXCEPT BYALICENSED Si 5 1 � r d •'y #,I ITS$ E f � ••����1 r- .�s' PROFESSIONAL IS ILLEGAL' A WRITTEN REPORT OF THE RESULTS OF THE TEST SHALL BE SIGNED BY THE PARTY '' CONDUCTING THE TEST AND PROVIDED TO THE CODE OFFICIAL. a R403.3.4 DUCT LEAKAGE (PRESCRIPTIVE). - �Drywall caulked, �I u� � Ra!lin� �l�n�� - y.. •, .. a THE TOTAL LEAKAGE OF THE DUCTS, WHERE MEASURED IN ACCORDANCE WITH SECTION ,. or gaAet d to bottDrn plan R403.3.3 SHALL BE AS FOLLOWS: Bottom plale caulked orpIt I �.� 1. ROUGH-IN TEST: THE TOTAL.LEAKAGE SHALL BE LESS THAN OR EQUAL TO 4 CUBIC FEET PER D:Sk�1�'d �� S�u�€IDer J a I -�". ; ;2 DOB EMPLOYEE STAMPS AND SIGNATURES MINUTE (113.3 UMIN)PER 100 SQUARE FEET(9.29 M2)OF CONDITIONED FLOOR AREA WHERE _ - + '' . ,�''•4 THE AIR HANDLER IS INSTALLED AT THE TIME OF THE TEST.WHERE THE AIR HANDLER IS NOT ,_ n , w tk. �*� c • S�� ��r glue, caulked �a �� ut � INSTALLED AT THE TIME OF THE TEST THE TOTAL LEAKAGE SHALL BE LESS THAN OR EQUAL I ; _ - _ _ ' � 10 rh JNSI'rl C10SU're. TO 3 CUBIC FEET PER MINUTE 85 UMIN PER 100 SQUARE FEET 9.29 M2 OF CONDITIONED FLOOR AREA. 1 ..�-. Rim ���� rim �1�s �r� u�~�� �r I tinktic to top Plato I, , 2. POSTCONSTRUCTION TEST: TOTAL LEAKAGE SHALL BE LESS THAN OR EQUAL TO 4 CUBIC FEET PER MINUTE (113.3 UMIN) PER 100 SQUARE FEET(9.29 M2)OF CONDITIONED FLOOR AREA. 4 .. r "iWl DB�.rlked, 1 ue'd Or - I I I R403.3.5 BUILDING CAVITIES (IMANDATORY). grasketed to top plale- as y pene1ratorr{, BUILDING FRAMING CAVITIES SHALL NOT BE USED AS DUCTS OR PLENUMS. I x' SHEET TITLE aV ENERGY gDSketed (0 bo('(011^I-[ pinte I C►"r! c " '"- � . F ¢,r k : RPI1eITv INOTES Bottom p1l1e ca_ rulRecl or ,. ��' _. R�r��� d {�1d:�k+� �I�r�rrr�I �Y gasketed t0 stabfloOr SubOloor lue caulked or s asketed 0 it 1 � I� •S s ' EMT,-° l 1 DOB NOW PROJECT NUMBER Ii 1C� rrrlr joist closure ti r, rtvi " r rjr.alar �I Rim joist,1l< m c1oSurB caulked ., s �? �: �'° VAd 'b".,3 ; T*r : rt ' 4o �. 1� � BSCAN 'd lt I - t R eLL ° 005 : ' dD ;IlIga ' ..e,, DI"! �. s`#,I1� pr; 1I1k'I .1 = ""d I 16 a Caulk *+ 9 ;y '� a n 4 `° .. . ,,. . . - .«..,...-,....K�,..�m,. �L.F r�I!•_ '1 i� i}r qn in �",�. It Silt plate installed ovt r° sIII gasket r�--,6 d �b •"J O DRAWING No. S Typical Air Barrier Detail T ical D wall Air Barrier Detail Electrical Back Box Air Barrier Detail 12 No. Scale- N.T.S. 2Scale- N.T.S. Scale- N.T.S. 1 OF 16 I , TABLE R402A.1.1 AIR BARRIER, AIR SEALING AND INSULATION INSTALLATION (A) COMPONENT AIR E'?ARRIER CRITERIA INSULATION INSTALLATION CRITERIA a [I a H CONSULVAN72 A CONTINUOUS AIR BARRIER SHALL BE AIR-PERMEABLE INSULATION SMALL ARCHITECT OF RECORD: INSTALLED IN THE BUILDING ENVELOPE. NOT BE USED AS A SEALING MATERIAL. DAVID CHAGNON,ARCHITECTURAL DESIGN PLLC GENERAL REQUIREMENTS BREAKS OR JOINTS IN THE AIR BARRIER E-MAIL: DC_FILING@DCARCH-NY.COM SHALL BE SEALED. "ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL IS ILLEGAL" CEILING/ATTIC THE AIR BARRIER IN ANY DROPPED CEILING THE INSULATION IN ANY DROPPED CEILING/SOFFIT �\ OR SOFFIT SHALL BE ALIGNED WITH THE INSULATION SHALL BE ALIGNED WITH THE AIR BARRIER AND ANY GAPS IN THE AIR BARRIER SHALL BE SEALED. ACCESS OPENINGS,DROP DOWN STAIRS OR KNEE WALL DOORS TO UNCONDITIONED ATTIC SPACES SHALL BE SEALED. !/ THE JUNCTION OF THE FOUNDATION AND SILL PLATE CAVITIES WITHIN CORNERS AND HEADERS OF FRAME CREATE!DESIGN/BUILD GROUP ARCHITECTURE-ENGINEERING-CONSTRUCTION SHALL BE SEALED WALLS SHALL BE INSULATED BY COMPLETELY FILLING E-MAIL:MMUNOZ@CREATEDESIGNBUILDGROUP.COM WALLS THE JUNCTION OF THE TOP PLATE AND THE TOP OF THE CAVITY WITH A MATERIAL HAVING A THERMAL TEL:631-464-6668 EXTERIOR WALLS SHALL BE SEALED. RESISTANCE,R-VALUE,OF NOT LESS THAN R-3 PER INCH. KNEE WALLS SHALL BE SEALED. EXTERIOR THERMAL ENVELOPE INSULATION FOR FRAMED WALLS SHALL BE INSTALLED IN SUBSTANTIAL CONTACT AND CONTINUOUS ALIGNMENT WITH THE AIR BARRIER WINDOWS,SKYLIGHTS THE SPACE BETWEEN FRAMING AND SKYLIGHTS,AND AND DOORS THE JAMBS OF WINDOWS AND DOORS,SHALL BE - SEALED. RIM JOISTS RIM JOISTS SHALL INCLUDE AN EXTERIOR AIR RIM JOISTS SHALL BE INSULATED SO THAT THE INSULATION BECKY SHEA DESIGN BARRIER(5) MAINTAINS PERMANENT CONTACT WITH THE EXTERIOR BECKY@BECKYSHEA.COM THE JUNCTIONS OF THE RIM BOARD TO THE SILL RIM BOARD. (5) PLATE AND THE RIM BOARD AND THE SUBFLOOR REVISION DATE DESCRIPTION SHALL BE AIR SEALED. #1 10.24.24 P.E. COMMENTS FLOORS, INCLUDING THE AIR BARRIER SHALL BE INSTALLED FLOOR FRAMING CAVITY INSULATION SHALL BE INSTALLED CANTILEVERED FLOORS AND At ANY EXPOSED EDGE OF INSULATION. TO MAINTAIN PERMANENT CONTACT WITH THE UNDERSIDE FLOORS ABOVE GARAGES OF SUBFLOOR DECKING.ALTERNATIVELY,FLOOR FRAMING CAVITY INSULATION SHALL BE IN CONTACT WITH THE TOP SIDE OF SHEATHING,OR CONTINUOUS INSULATION INSTALLED ON THE UNDERSIDE OF FLOOR FRAMING CONSTRUCTION ADMINISTRATION BY: AND EXTENDING FROM THE BOTTOM TO THE TOP OF ALL PERIMETER FLOOR FRAMING MEMBERS. TO BE DETERMINED CLIENT: DATE: SCALE: EXPOSED EARTH IN UNVENTED CRAWL SPACES BARRIER CRAWL SPACE INSULATION,WHERE PROVIDED INSTEAD ALONZO FAMILY 12/24/22 AS SHOWN BASEMENT CRAWL SPACE SHALL BE COVERED WITH A CLASS I VAPOR OF FLOOR INSULATION,SHALL BE INSTALLED AND SLAB FOUNDATIONS RETARDER/AIR IN ACCORDANCE WITH SECTION R4022J0. IN ACCORDANCE WITH SECTION R4022.10. CLIENT/ADDRESS/SCOPE OF WORK PENETRATIONS THROUGH CONCRETE FOUNDATION CONDITIONED BASEMENT FOUNDATION WALL PRIV WALLS AND SLABS SHALL BE AIR SEALED. INSULATION SHALL BE INSTALLED IN ATE ACCORDANCE WITH SECTION R402.20.1. CLASS 1 VAPOR RETARDERS SHALL NOT BE USED RESIm:NCE, AS AN AIR BARRIER ON BELOW-GRADE WALLS SLAB-ON-GRADE FLOOR INSULATION SHALL BE AND SHALL BE INSTALLED IN ACCORDANCE WITH INSTALLED IN ACCORDANCE WITH SECTION R402.2.10. SECTION R102.1 OF THE INTERNATIONAL RESIDENTIAL CODE. CEDARS ROAD DUCT TI FLUE SHAFTS TO SHAFTS,PENETRATIONS UNCONDITIONED SPACE SHALL BE I SEALED. (PASSING THROUGH SHAFTS AND PENETRATIONS TI UTILITIES C U TC H O G U E, N.`1�. IN THE BUILDING THERMAL ENVELOPE t0 UTILITY PENETRATIONS OF THE AIR BARRIER SHALL MAINTAIN REQUIRED R-VALUE. BE CAULKED,GASKETED OR ISE SEAD AND SHALL ALLOW FOR EXPANSIONN,CONTTRA EON NEW RESIDENCE OF MATERIALS AND MECHANICAL VIBRATION. NARROW CAVITIES OF I INCH OR LESS THAT ARE BATTS t0 BE INSTALLED IN NARROW CAVITIES SHALL ARCHITECTURAL SEAL: ARCHITECT OF RECORD: DAVID CHAGNON, NARROW CAVITIES NOT ABLE TO BE INSULATED SHALL BE AIR SEALED. BE CUT TO FIT OR NARROW CAVITIES SHALL BE ARCHITECTURAL RED AR DESIGN PLLC FILLED WITH INSULATION THAT ON INSTALLATION �ti C E-MAIL: READILY CONFORMS TO THE AVAILABLE CAVITY SPACE. I c k Cl DC FILING@DCARCH-NY.COM 4q Nil � tr GARAGE SEPARATION AIR SEALING SHALL BE PROVIDED BETWEEN THE INSULATED PORTIONS OF THE GARAGE SEPARATION ASSEMBLY * ; GARAGE AND CONDITIONED SPACES. SHALL BE INSTALLED IN ACCORDANCE WITH SECTIONS R303 AND R4022.1. 04 2 8'3g y0¢ RECESSED LIGHT FIXTURES INSTALLED IN THE RECESSED LIGHT FIXTURES INSTALLED IN THE OF N "ALTERATION OF THIS DOCUMENT p�� `� EXCEPT BY A LICENSED RECESSED LIGHTING BUILDING THERMAL ENVELOPE SHALL BE AIR BUILDING THE p��M UAL ENVELOPE WALL PROFESSIONAL IS ILLEGAL" SEALED IN ACCORDANCE WITH SECTION R402.45. BE AIRTIGHT AND IC RATED,AND SHALL BE BURIED OR SURROUNDED WITH INSULATION. ALL HOLES CREATED BY WIRING, PLUMBING INSULATION SHALL BE INSTALLED TO FILL PLUMBING,WIRING OR OR OTHER OBSTRUCTIONS IN THE AIR THE AVAILABLE SPACE AND SURROUND WIRING, OTHER OBSTRUCTIONS BARRIER ASSEMBLY SHALL BE AIR SEALED. PLUMBING,OR OTHER OBSTRUCTIONS,UNLESS THE REQUIRED R-VALUE CAN BE MET BY INSTALLING INSULATION AND AIR BARRIER SYSTEMS COMPLETELY TO THE EXTERIOR SIDE OF THE OBSTRUCTIONS. DOB EMPLOYEE STAMPS AND SIGNATURES THE AIR BARRIER INSTALLED At EXTERIOR WALLS SHOWER/TUB ON ADJACENT t0 SHOWERS AND TUBS SHALL EXTERIOR WALLS ADJACENT TO SHOWERS EXTERIOR WALL SEPARATE THE WALL FROM THE SHOWER OR TUB. AND TUBS SHALL BE INSULATED. THE AIR BARRIER SHALL BE INSTALLED BEHIND ELECTIRICAL/PHONE BOX ELECTRICAL AND COMMUNICATION BOXES.ON EXTERIOR WALLS ALTERNATIVELY,AIR-SEALED BOXES SHALL BE INSTALLED. HVAC SUPPLY AND RETURN REGISTER BOOTS HVAC REGISTER BOOTS THAT PENETRATE BUILDING THERMAL ENVELOPE - SHALL BE SEALED TO THE SUBFLOOR,WALL COVERING OR CEILING FE14ETRATED BY THE BOOT. SHEET TITLE WHERE REQUIRED t0 BE SEALED,CONCEALED CONCEALED SPRINKLERS FIRE SPRINKLERS SHALL ONLY BE SEALED IN A MANNER THAT IS RECOMMENDED BY THE MANUFACTURER - AIRBjqRRIER, CAULKING OR OTHER ADHESIVE SEALANTS SHALL NOT BE USED t0 FILL VOIDS BETWEEN FIRE SPRINKLER COVER PLATES AND WALLS OR CEILINGS. _1 - AIR SEMLIN"G4, A. INSPECTION OF LOG WALLS SHALL BE IN ACCORDANCE WITH THE PROVISIONS OF ICC 400. AR ND B. AIR BARRIER AND INSULATION FULL ENCLOSURE IS NOT REQUIRED IN UNCONDITIONED/VENTILATED ATTIC SPACES AND AT RIM JOISTS. Il''16 U LA T 10 14 DOB NOW PROJECT NUMBER BSCAN DRAWING No. SHEET No. 13 CF 16 I D E a CC SLYL7AHUS ARCHITECT OF RECORD: DAVID CHAGNON,ARCHITECTURAL DESIGN PLLC E-MAIL: DC_FILING@DCARCH-NY.COM "ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL IS ILLEGAL" NOTES : LEGEND : I. WHITE DECORA RECEPTACLES t SWITCHES INDICATES PHONE/DATA JACK CREATE! DESIGN/BUILD GROUP 2. CONTRACTOR TO CONSULT W/OWNER MZIOR TO INDICATES DUPLEX RECEPTACLE ARCHITECTURE-ENGINEERING-CONSTRUCTION INSTALLATION,REGARDING ANY EXTERIOR 12-18"AFF.(TYP) lii E-MAIL:MMUNOZ@CREATEDESIGNBUILDGROUP.COM MOTION DETECTOR e FLOOD LIGHT LOCATIONS. TEL:631-464-6668 INDICATES DUPLEX RECEPTACLE GFI 3. CONTRACTOR TO CONSULT W/OWNER MZIOR TO W/GROUND FAULT INTERRUPTER INSTALLATION,ANY ADDITIONAL LIGHTING, MOUNTED HORIZONTALLY 6 44" AFF. POWER CABLE,AND PHONE REQUIREMENTS AND LOCATIONS. INDICATES DUPLEX RECEPTACLE .•I COORDINATE WITH APPLIANCE FOR•_ �r 4,— — — —,•„— :,,^.'•�•.•r;=.,,. .,. ..•'.�`' ,i.: ,• ( • t. IC-RATED RECESSED LIGHTING FIXTURES SEALED REQUIRED SPECIFICATIONS. AT HOUSING/INTERIOR FINISH AND LABELED TO INDICATES RECESSED GLG. +HH �t, I "•-::� .i.;y ^ l.7771 INDICATE <_2.0 CFM LEAKAGE AT 75 PA. :. I I 1, 4 l ,, '•. ! + LIGHT FIXTURE BECKY SHEA DESIGN I — — _ _ — — — — — — — •''" ' ' '. ,rr-�. .• — — — — INDICATES MONOPOINT C'LG. *MP BECKY@BECKYSHEA.COM :.: * >,:i:.•:••. 'i: NOTE: J.• ,. .:• .: ,..•. '..'.1 t.•,. -_r" ,! AL PROVIDED ELECTRICAL IS TO LIGHT FIXTURE :'i:•:; L PR DED ELE TR L BE REVISION f, ,. ., .. •Y:,^• ^,.•�'•:�•;r^.• •.a' ,. DATE DESCRIPTION I ��; •:'(�" ', •is•.«� — — — — — — — — — — :9 :' INSTALLED IN ACCORDANCE TO THE 2020 INDICATES FLUSH MOUNT GLG. — �` INTERNATIONAL RESIDENTIAL CODE CHAPTER LIGHT FIXTURE #1 10.24.24 P.E. COMMENTS 34 TO 43 AND THE NATIONAL ELECTRIC CODE (NECY NFPA '10. INDICATES PENDANT CLG. E LIGHT FIXTURE '- ' Y "-~ 1 ST FL. KEY NOTES : ;s•• i,' INDICATES RECESSED CI.G. Owp WATER-PROOF LIGHT FIXTURE f� I. PROVIDE HARD WIRED LOCATION FOR SMART INTERIOR WALL SCONCE •.• ► `e•', IS CONSTRUCTION ADMINISTRATION BY: C�+ CAE SLAB I I DOOR BELL/CAMERA ,a, 3O TO BE DETERMINED ^ 2. CONTRACTOR TO PROVIDE POWER IN GARAGE EXTERIOR WALL SCONCE: ES PROP. CRAWL SP,�CE I `' FOR ELECTRIC VEHICLE • * UTILITY I �/ UTI IT I : '?I: I I -� :•� I CLIENT: DATE: SCALE: 1 ;oo,� PROPOSED DOII�I LIGHT ON POST �L ALONZO FAMILY 12/24/22 AS SHOWN :'•�Y I CR,4WL I :�': 2 N D. F L. KEY NOTES : INDICATES SWITCHSPA 48-52" AFF.(TYP.) �' CLIENT/ADDRESS/SCOPE OF WORK H I �- -- - : .� I 1. T.V.OUTLETS TO BE A RECESSED CLOCK OUTLET INDICATES 3-WAY SWITCH $3 I s .• AT 60" AFF.,DATA TO ALSO BE INSTALLED AT T I r�. I ; "•' �'•; •' I 6011 AFF.CONTRACTOR TO CONSULT WITH INDICATES DIMMER SWITCHF%p rw :::; I `' HOMEOWNER FOR T.V.LOCATIONS. INDICATES EXHAUST FAN 1100 c.fm.) R Em S I D E IN"C a' r "y .. '••; := c.;:�::e, :r.: :' '�; :.._7 d.— 17 . INDICATES SMOKE DETECTOR � . I - s.'. I INDICATES CARBON MO1dOXIDE • }' I CEDARS ROAD .• , S , , , , , , , , �:.:;, DETECTOR CUTCHOGUE, N.Y. ' LE E •�::• '+• •• P fiJE ANEL A. I I 1 1 I I °•.•'••• INDICATES LED LIGHT STRIP/ II � � I � i `�'•• UNDER CABINET LIGHTING ..,;'. rt'.'•j•;;'•,f• '.,'• :•• :•4' •s•+.'.•.'•,�,a�Z. :a :'a :i•I" .t�••'::ar + .,,. .y,••4.. � .' f< 'L. • 1.' ,}.• �•'• 1. ,�r• '•'' I � — - - - — — - - - - - - - - - - - "" ' NEW RESIDENCE :�••:;• H H" 5 INDICATES NEW CEILING FAN WITH 4'.. I LIGHT AND REMOTE TO BE SELECTED BY OWNER +' 'A I INDICATES TRACK LIGHT ARCHITECTURAL SEAL: ARCHITECT OF RECORD: DAVID CHAGNON, a p ARCHITECTURAL :;'',j•, I BRED ARC` DESIGN PLLC ••' f C?�0� �RIcK C � DC FILING@DCARCH-NY,COM FROPOSED �'A ' DC ( ' i SPORTS/ '•r• � � ti � -vim t I THEATER o •:•` I I PROP Nr Iz WET 5AR I AREA I •� `n 4 GFI I orr2B3� �O 4 �1 a � ,• "ALTERATION OF THIS DOCUMENT EXCEP••• I I 1: —_ -- Y A LICENSED PROFESSIONAL AL IS ILLEGAL" I �'�!� ,�Ft' v�' .ti�. . � °,. �'�:;✓'..if:^%' .:r.a :� s •'::tr ':•i, ram::;+.t• HH HILI GFlII ••^.' �4 F1' . DOB EMPLOYEE STAMPS AND SIGNATURES FIVI PROP. CRAWL r • - s ' . '.'• HH ' S I I I O PROPOSEC� ' HH RECREATI q •: :1 HH ; HH SHEET TITLE .f ' j • . '... may.. ':,,:.• ....."I r- .• •''•:�(',2w� :•;'.r:'i.�•; i '�••e .a•.. ..1••.• ..Y`•Y•'•,''..a• .V•i•'r„•�. a '=a� i• .1.,•• •..n:".. "l.;:w•r•:,l�f•" EUCTMCAL CELLAR ELECTRIC.-AL FLAN L S OC:ALE: 1/411 = 11-011 3 DOB NOW PROJECT NUMBER zz BSCAN DRAWING No. SHEET No. All Ala 14 OF 16 r I c�© H95UL AH73 PROPOSED HH FROP ARCHITECT OF RECORD: HH O C:H HH PORCH HH DAVID CHAGNON,ARCHITECTURAL DESIGN PLLC E-MAIL: DC_FILING@DCARCH-NY.COM H HH "ALTERATION OF THIS DOCUMENT EXCEPT BY LICENSED PROFESSIONAL iS ILLEGAL" I HH 9;pl --- ------)iHi ----------- I ------ `f� I D - I I HH PROPOSED I H M HH HH HH o H I I I H HH HH MU E G I I Mp -� CREATE!DESIGN/BUILD GROUP ROOM I III ARCHITECTURE-ENGINEERING-CONSTRUCTION I PROPOSED I I E-MAIL:MMUNOZ@CREATEDESIGNBUILDGROUP.COM H EF w HH IVINC O O I I TEL:631-464-6668 I I HH Mp HH 70 ROOM O O I 1 CIF I I I 1 HH HH HH I I I I 3 PROPOSEQ ., I' HH " I I NULL I I l O OS HH FM HH I HH HH I I BECKY SHEA DESIGN I I I BECKY@BECKYSHEA.COM I D3 OY I III I 3 I 11 REVISION DATE DESCRIPTION I HH H HH 3 HH I PROPOSED i 1 #1 10.24.24 P.E. COMMENTS D3 SD C_oVr=REl,-PECX II O I ;II _ _ ------------------------ ___ _______________ I I I CONSTRUCTION ADMINISTRATION BY: HH HH TO BE DETERMINED I HH H I I I CLIENT: DATE: SCALE: ALONZO FAMILY 12/24/22 AS SHOWN I OO I I D � CLIENT/ADDRESS!SCOPE OF WORK PROP" NDEUER OPEN TO I OY � II II PRIVATE I I HH HH HH RESIDENCE I I PROF, I Q i HH HH �— I 3 :ES D3 3 I o Os CEDARS ROAD IS -------------- D aoM 77 CUTCHOGUE, N.Y. 1 � G I ON,) HH HH ------------- ------------ —.I I NEW RESIDENCE I HH PROPOSED SD D HH HH OIREAKFAST I �OOM ARCHITECTURAL SEAL: ARCHITECT OF RECORD: HH HH -- DAVID CHAGNON, --I-- -- --- -- E ! { /1 ARCHITECTURAL --- -- ----� E -- PROPOSED ��RE�AROy E-MAILN PLLC HH O G j E OUTDOOR ��� P'(RICK C1���`� DC FILING@DCARCH-NY.COM --;-- _1_ P KITCHEN r�``' o „�� `� -'-A RotZOSED , - -, r----�F---- ATH O PLAYROOM i i i i ii y o R OM I I U I I N D C H HH G 1 HH HH 9r4�' 042g3c © PROPOSED HH PROPOSED ALTERATION BY LICENSED ENT _ I 1 1 PROFESSIONAL IS ILLEGAL" I HH KITCHEN H EXCEPT BV A LICENSED BUILT-IN - -- S GRILL NOTE' ES ES I I I PH I l K �10: THE LOCATIONS OF ALL ELECTRICAL I I Yn I 1 O I 1 OGFI 1 I GFI I 0 COMPONENTS ARE ESTIMATED AND SHOULD BE s ES REVIEWED AND VERIFIED IN FIELD BY THE HOMEOWNER AND GENERAL CONTRACTOR. DOB EMPLOYEE STAMPS AND SIGNATURES a a a o a o a o CONTRACTOR TO VERIFY FINAL LOCATION OF ALL NOTES : KITCHEN EQUIPMENT AND APPLIANCES AND PROVIDE THE APPROPRIATE POUTER AT THE 1. WHITE DECORA RECEPTACLES t SWITCHES CORRECT LOCATION FOR ALL COMPONENTS, OPOSED 2. CONTRACTOR TO CONSULT W/OWNER PRIOR t0 INCLUDING AT THE KITCHEN ISLAND. INSTALLATION,REGARDING ANY EXTERIOR MOTION DETECTOR t FLOOD LIGHT LOCATIONS. 3. CONTRACTOR TO CONSULT W/OWNER PRIOR TO INSTALLATION,ANY ADDITIONAL LIGHTING, POWER,CABLE,AND PHONE REQUIREMENTS AND LOCATIONS. LEGEND : _ SHEET TITLE IC-RATED RECESSED LIGHTING FIXTURES SEALED INDICATES RECESSED CLG. VVf> IRS ' FLOOR PLAN AT HOUSING/NTERIOR FINISH AN ®D LABELED TO INDICATES PHONE/DATA JACK T WATER-PROOF LIGHT FIXTURE SGAL.E: I/4 1 0„ INDICATE 52.0 CFM LEAKAGE AT 75 PA. INDICATES DUPLEX RECEPTACLE INTERIOR WALL SCONCE �IS 12-1811APP.(TYP.) NOTE INDICATES DUPLEX RECEPTACLE EXTERIOR WALL SCONCE .e.ES ALL PROVIDED ELECTRICAL IS TO BE W/GROUND FAULT INTERRUPTER CFI ELECTRIC L. INSTALLED IN ACCORDANCE TO THE 2020 MOUNTED HORIZONTALLY ® 44" AFF. INDICATES SWITCH INTERNATIONAL RESIDENTIAL CODE CHAPTER 48-52" AFF.(TYP) $ P L Am 1 rM S 34 TO 43 AND THE NATIONAL ELECTRIC CODE INDICATES DUPLEX RECEPTACLE (NEC)/NFPA "10. COORDINATE WITH APPLIANCE FOR DED. INDICATES 3-WAY SWITCH 1ST FL. KEY NOTES : REQUIRED SPECIFICATIONS. INDICATES DIMMER SWITCH $D INDICATES RECESSED CLG. *HH LIGHT FIXTURE INDICATES EXHAUST FAN 1100 c.fma DOB NOW PROJECT NUMBER I. PROVIDE HARD WIRED LOCATION FOR SMART INDICATES MONOPOINt CLG. MP DOOR BELL/CAMERA. INDICATES SMOKE DETECTOR LIGHT FIXTURE 2. CONTRACTOR TO PROVIDE POWER IN GARAGE ® BSCAN FOR ELECTRIC VEHICLE INDICATES FLUSH MOUNT CLG. M INDICATES CARBON MONOXIDE LIGHT FIXTURE DETECTOR 2ND. FL. KEY NOTES : INDICATES PENDANT CLG. E INDICATES LED LIGHT STRIP/ - - - - LIGHT FIXTURE UNDER CABINET LIGHTING 1. T.V.OUTLETS TO BE A RECESSED CLOCK OUTLET INDICATES NEW CEILING FAN WITH AT 60" APP.,DATA TO ALSO BE INSTALLED At DRAWING No. SHEET No. 60" AFF. CONTRACTOR t0 CONSULT UITH LIGHT AND REMOTE TO BE HOMEOWNER FOR T.V.LOCATIONS. SELECTED BY OWNER ® 15 + OF 16 D E a 0 a v CONSUL'TAM S ARCHITECT OF RECORD: D.AVID CHAGNON,ARCHITECTURAL DESIGN PLLC E-MAIL: DC_FILING@DCARCH-NY.COM "ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL IS ILLEGAL" CREATE! DESIGN/BUILD GROUP _ - ARCHITECTURE-ENGINEERING-CONSTRUCTION SS �� EMAIL:MMUNOZ@CREATEDESIGNBUILDGROUP.COM TEL:631-464-6668 G EF ,... . 1 H FM H WP AW 13ATHRO 104 _ MP S S ES P 013(r— R — ---- P -- D3 HH II BECKY SHEA DESIGN II HH BECKY@BECKYSHEA.COM I HH PROPOSEDDB H I ® REVISION DATE DESCRIPTION BEDROOM 04 b PR P #1 10.24.24 P.E. COMMENTS MP m RT& H UJASN.I CHANDELIER II .,D r� Y � II'� I I 5D ROOF OF I H HH --------Gip/ / E }BELOW c �J SD e�OPOSED CONSTRUCTION ADMINISTRATION BY: HH HH TO BE DETERMINED CLIENT: DATE: SCALE: PROPOSED MP ALONZO FAMILY 12/24/22 AS SHOWN H H SD H H N,4 s H CLIENT/ADDRESS/SCOPE OF WORK I I PROPOSED PRIVATE HH D3 I I — BALCONY HH D H D w D4 IAN CLOSET i Fl EF IDENCE ----i r__j H I I 3 IS NOTES : LEGEND : - -_ _ —_ -- S I -- HIS - CUTCHOGUE, N.Y. 1. WHITE DECORA RECEPTACLES 4 SWITCHES INDICATES PHONE/DATA JACK �► OPEN t0 II CLOSET CLOSET II DELOW II MAST OSET ;I 2. CONTRACTOR TO CONSULT W/OWNER PRIOR TO INDICATES DUPLEX RECEPTACLE II II INSTALLATION,REGARDING ANY EXTERIOR 12-18"AFF.(TYP) MP II E HH �I ® NEW RESIDENCE HH MOTION DETECTOR 4 FLOOD LIGHT LOCATIONS. I ,4 ON1' I 1 II INDICATES DUPLEX RECEPTACLE GFI I O OS li it 3. CONTRACTOR TO CONSULT W/OWNER PRIOR TO W/GROUND FAULT INTERRUPTER HALL ARCHITECTURAL SEAL: ARCHITECT OF RECORD: INSTALLATION,ANY ADDITIONAL LIGHTING, MOUNTED HORIZONTALLY Al44" AFF. II II DAVID CHAGNON, POWER CABLE,AND PHONE REQUIREMENTS AND li 3 it RED AR " DESIGN PLLC LOCATIONS. INDICATES DUPLEX R-CEPTACLE E E-MAIL: lC i ARCHITECTURAL DED. I �� C'C DC FILING@DCARCH-NY.COM COORDINATE WITH AF�PLIANCE FOR (RK REQUIRED SPECIFICATIONS. Is Is Es s Q F�> IC-RATED RECESSED LIGHTING FIXTURES SEALED G� AT HOUSINGANTERIOR FINISH AND LABELED TO INDICATES RECESSED CLG. HH I INDICATE <_2.0 CFM LEAKAGE AT 75 PA. '� HH HH LIGHT FIXTURE SD INDICATES MONOPOINT CLG. MP ® N� 9 04283' O O� LIGHT FIXTURE D D3 HH H p D3- HH o TIC` F �� ALL PROVIDED ELECTRICAL IS TO BE c'' N INSTALLED IN ACCORDANCE t0 THE 2020 INDICATES FLUSH MOUNT CLG. ahFM ALTERATION OT OF THIS DOCUMENT INTEFNATIONAL RESIDENTIAL CODE CHAPTER LIGHT FIXTURE O OWED ! PRO ESSIONAL SILLEOAL" 34 TO 43 AND THE NATIONAL ELECTRIC CODE H�H M :mR -- --- INEC)/NFPA 10. INDICATES PENDANT CLG. E LIGHT FIXTURE HH PROPOSED H P O OS BEDROOM li �. 1 ST FL. KEY NOTES : INDICATES RECESSED CLG. WP _ BEDROOM COFFEE ;- WATER-PROOF LIGHT FIXTURE i *3 $ 15AR D3 - D I HH E I. PROVIDE HARD WIRED LOCATION FOR SMART INTERIOR WALL SCONCE 41s H I CHANDELIER PROPOSED DOOR BELL/CAMERA. I E G _� M,4StER E3,d►tH 2. CONTRACTOR TO PROVIDE POWER IN GARAGE EXTERIOR WALL SCONCE ES I --- — — — DOB EMPLOYEE STAMPS AND SIGNATURES FOR ELECTRIC VEHICLE I - IS M DOWN LIGHT ON POST EF I 2 N D. F L. KEY NOTE INDICATES SWITCH " 48-52" AFF. (TYP.) # I I 1. T.V.OUTLETS TO BE A RECESSED CLOCK OUTLET INDICATES 3-WAY SWITCH $3 i E HH AT 60" AFF,DATA TO ALSO BE INSTALLED AT I HH HH EF 60' AFF.CONTRACTOR TO CONSULT WITH INDICATES DIMMER SWITCH $D I HH HOMEOWNER FOR T.V.LOCATIONS. I INDICATES EXHAUST FAN (100 cf n) ®INDICATES SMOKE DETECTOR PE E INDICATES CAR50N MONOXIDE SECOND FLOOR ELEC. PLAN DETECTOR ® SCALE: 1/4" = 1'-0" SHEET TITLE INDICATES LED LIGHT STRIP/ — — — — UNDER CABINET LIGHTING INDICATES NEW CEILING FAN WITH LIGHT AND REMOTE TO BE SELECTED BY OWNER. L E Cullm I CA L INDICATES TRACK LIGHT — - - — A rilS PLAim DOB NOW PROJECT NUMBER BE CAN DRAWING No. SHEET No. 16 M= 14 OF 16 0E I ERAL S I �50L— <E*Nr : EXISTING TO BE DEMOLISHED b77777T,�f I HOOD FR ME ( G. STL. Q EXISTING TO REMAIN `I WHEN APPLICABLE) 0 uj NEW WOOD FRAME (L.6. NEW FOUNDATION WALL J Ca STL. WHEN APPLICABLE) (y) MIN. (2) 2"x4" STRUCTURAL N._ NEW I-HR FIRE RATED P05T FOR 4" WALLS ¢ a-.+ El WOOD FRAME (L.6. STL. (MIN. (2) 2"xb" 5TRUCTURAI O WHEN APPLICABLE) POST FOR (b" WALLS), U.O.N. C 7t5 NEW 2-HR FIRE RATED � C9 WOOD FRAME (L.6. STL. %� NEW PLUMBING WALL L WHEN APPLICABLE) CL Lr) -,z i C X = N O O O +' C4 26'-pi" 25'-O" 26'-6" ate--+ 0 a� co4-+ 2q'-10" � 10' (V-3" 28'-O" Q or- -7- O co — — — — — — — — -- — — — — 4-1 70 - ry U • PROPOSED 1Ym 6ARA6E 5LA1B ABOVE m W 151-q" ■ � 5 GL6 H6T. N PROPOSED O /r •— MECH. ROOM ' \` 4111 5F _5 in CONTRACTOR TO PROVIDE GL6. HOT. A NAVIEN TANKLESS am WATER HEATER d Q HYDRONIG AIR HANDLER f FOR FORGED AIR HEATIN6 N GL6. HOT. ,� m NEW WOOD sp - HANDRAIL ' ui z W 26'-3" s W z z 8—p 4 d - W m m Eno GL6. HOT. `� ~ m x y •• {. .• Y , I W W Q �j O z PROPOSED `—r C) Q GONG. PATIO ABOVE I 1 N (D PROPOSED � M 0 BASEMENT � 1948 SF O 0 � PROJECT: m O GL6. HOT, dJ ALONZO RESIDENCE 2050 NEW SUFFOLK ROAD CUTCHOGUE, NY 11935 SUMP PUMP DRAWING TITLE: PROPOSED BASEMENT PLAN EW 8 WIDE FND. BALL BELOW CEDAR OLUMNS. \� o-1 PAGE: o PROPOSED GONG. PATIO A-101m00 ABOVE \ ! iV U DATE: 11/05/25 5 OF XX I , o — — — — — .—° — — — — — — — — — — — — - — — — — — — — — — — — — — — — — — — — — — — — — — — - s — — — —� N .•'1 1� f FROFOSF-17 BASEMENT PLAN SCALE: 1/4" = I'-O"