Loading...
HomeMy WebLinkAboutSubject File BULK REQUIREMENTS GENERAL NOTES / 1. ZONE: GENERAL BUSINESS (B) DISTRICT 1. PROPERTY OWNER/ APPLICANT: HIGH •r 2. USE: AMAC INC. & 535 OLD MAIN REALTY LLC 2.1. PER 280-48(B)-12 - GASOLINE SERVICE STATION REQUIRES SPECIAL EXCEPTION BY BOARD OF APPEALS. P.O. BOX 547 2.2. PER 280-48(A).2(A) - RETAIL STORE > 1.200 SF CONSIIDERED 2nd PRINCIPAL USE. LAUREL, NY 11948 3. BULK REQUIREMENTS: CODE SECTION: PERMITTED: PROVIDED: 2. THIS PLAN REFERENCES: / POINT - A SURVEY PREPARED BY: MIN. LOT SIZE: § 240-48-c-5 60,000 SF 63,308 SF (1.453 ACRES) NATHAN TAFT CORWIN III ' ENGINEERING ' MIN. FRONT YARD: § 280-50a 100' MAIN RD. (NYS 25) - FLOOR DATED: 8/9/23 PLANS & ELEVATIONS PREPARED BY: 74.7' (BLDG.)* THIS FIRM j 44.6' (CANOPY)* DATED: 5/23/24 (REV. 1) N PROP. CONC. CURB / OLD MAIN RD, 3. ANY BROKEN OR HAZARDOUS SIDEWALK, DRIVEWAY APRONS OR CURB ADJACENT TO THE SUBJECT SITE ` ` IT 60 (NYSDOT ITEM i I ' '6 1860 WALT WHMAN ROAD 66.2' (BLDG.) SHALL BE REPLACED IN ACCORDANCE WITH CURRENT COUNTY/ TOWN STANDARDS. # 9.0401) (TYP.) ' III SUITE 600 33.8' (CANOPY)* 4. CURB-CUTS AND/ OR ACCESS TO TOWN, COUNTY, STATE, ETC. HIGHWAYS SHALL BE CERTIFIED BY THE o j 'yy" MELVILLE,NY 11747 MUNICIPALITY HAVING JURISDICTION. J MAX. STRUCTURE FRONTAGE (LENGTH): § 280-50c 60' 58.3' (BLDG.) 5. DEBRIS SHALL NOT BE BURIED ON THE SUBJECT SITE. ALL UNSUITABLE MATERIAL AND DEBRIS SHALL BE / (516)777-4320 FAX: (516)777-4321 59.0' (CANOPY) DISPOSED OF IN ACCORDANCE WITH ALL LOCAL TOWN, COUNTY, STATE AND FEDERAL LAWS AND APPLICABLE W / MEET EXIST. SIDEWALK/ GRADE/ CODES. I► CURB ROADWAY FLUSH MIN. STRUCTURE SETBACK FROM R.O.W. § 280-50c 75' MAIN RD. (NYS 25) 6. THE OWNER CONTRACTOR SHALL BE FAMILIAR WITH AND RESPONSIBLE FOR ANY ALL CERTIFICATIONS, / / / / E �� s• ` ` ALL PHASES OF ENGINEERING DESIGN 75.9' (BLDG.) INSPECTIONS, ETC. REQUIRED BY ALL GOVERNING JURISDICTIONAL AGENCIES DURING AND AFTER .-, i? ' EXIST SPEED LIMIT / SURVEYING,CODE CONSULTING, 44.6' (CANOPY)* CONSTRUCTION FOR SIGN-OFF' AND CERTIFICATE OF OCCUPANCY ISSUANCE, INCLUDING BUT NOT LIMITED TO o .` ° N/O/F PROCUREMENT OF SERVICES, SCHEDULING OF FIELD OBSERVATIONS AND COORDINATION WITH 40'SIGN TO REMAIN / , s COPAM REALTY COMPANY ZONING ANALYSIS&BID SPECIFICATION OLD MAIN RD. REPRESENTATIVES OF THE APPROPRIATE PARTIES, 66.2' (BLDG.)* 7. ENGINEER OF RECORD NOT RESPONSIBLE FOR PREPARATION, MONITORING OR REVIEW OF CONTRACTOR'S 33.8' (CANOPY)* SITE SAFETY PLAN. CONTRACTOR ACKNOWLEDGES THAT COMPLETE RESPONSIBILITY FOR JOB SITE SAFETY I ,Jx ® 6'•s� ZONE: GENERAL BUSINESS (B) LIES WITH HIMSELF AND THOSE PARTIES UNDER HIS DIRECTION. ' / ° s� USE: McDONALDS RESTAURANT WWW.HPEng.com MIN. LOT WIDTH: § 280-ATTACHMENTF 4 150' 462.42 8. THE APPURTENANCESR(WHETH(IS WHETHER DEIPICTED 0 THESBLE FOR E PLANS OR NOT) PRIOR TONG THE EXACT LOCATION OTHE START OF WORK.DEPTH OF ALL THE °F MIN. LOT DEPTH: § 280-ATTACHMENTF 4 150' 95.20 CONTRACTOR MUST CONTACT THE "ONE CALL" SYSTEM TO ENSURE THAT ALL UTILITIES ARE PROPERLY AND Fa CHRIS M. TAR TA GLIA MIN. SIDE YARD: § 280-ATTACHMENTF 4 25' 25' (BLDG.) COMPLETELY MARKED OUT PRIOR TO PERFORMING ANY WORK. ANY DISCREPANCIES BETWEEN THE FIELD �E 124.6' (CANOPY) LOCATIONS AND THE PLANS MUST BE VERIFIED BY THE CONTRACTOR. ANY DAMAGE OR STRUCTURE / . PROP. HOT BOX 9�, �QF DISTURBED DURING CONSTRUCTION MUST BE REPAIRED OR REPLACED AT THE CONTRACTOR'S EXPENSE. / ° / f W/ RPZ DEVICE 9. CONTRACTOR TO COORDINATE W/ ENVIRONMENTAL CONSULTANT TO CONFIRM IF EXISTING MONITORING WELLS MIN. REAR YARD: § 280-ATTACHMENIT 4 35' N/A (CORNER LOT) DISTURBED/ REMOVED DURING CONSTRUCTION MUST BE REPLACED. ° /� SHADED AREA Q MIN. LANDSCAPE AREA PERCENTAGE: § 280-ATTACHMENIF 4 35% 36,742 SF (58.0%) / v ,. / ✓� DEPICTS PROPOSED / STORMWATER MAX. LOT COVERAGE: § 280-ATTACHMENY 4 30% 7,169.2 SF (11.3%) INFILTRATION BASIN tL 1 MAX. BLDG. HT./ STORIES: § 280-ATTACHMENIT 4 35'/2 STORIES 33'-6"/2 STORIES / / y CORNER LOT SIGHT LINE DISTANCE: § 280-106(A) 30' SIDES COMPLIES 07824� MIN. ACCESSORY STRUCTURE SETBACK § 280-15(B) 20 25' (TRASH ENCLOSURE) PROP. CONC. CURB ° ° . ` / (FOR LOT SIZE 60,000-79,999 SF): NGINEER FOR SIDE AND/OR REAR YARD (NYSDOT ITEM / PROP 9'X19' PR / /f609.0401) (TYP.) / / LANDBANKED NEW YORK LICENSE No. 078209 MIN./ MAX. DRIVEWAY WIDTH: § 280-48(B)12(a) 12'/30' 30' MAIN RD. NYS 25) . ,, PARKING STALL ��. z 30' (OLD MAIN RD.) ' / (TYP. of 12) •moo / LAWRENCE D. 0 BRIEN MIN. DRIVEWAY DIST. FROM ADJACENT h': § 280-48(B)12(a) 10' 172.0' MIN. TANK DIST. FROM ADJACENT It: § 280-48(B)12(e) 35' 105.5' 0 INLET r0 / "' `�. / LINE OF EXIST MIN. DISP. DIST. FROM R.O.W. it: § 280-48(B)12(f) 15' 46.1' REMAIN PROP. DENSE VEGETA77ON � LANDSCAPE AREA TO REMAIN / MIN. TANK FROM R.O.W. EL' § 280-48(B)12(f) 15' 15' PROP. LOCATION OF�� �� (TYP-)DISCHARGE PIPE & / .�N MIN. DIST. FROM CHURCH, § 280-48(B)12(g) 300' 1.5 MILES (MAT11TUCK-CUTCHOGUE �y1Q / /� GRAVEL PIT IN / ,�N. SCHOOL, ETC. JR./SR. HIGH SCHOOL) '�� OQ���1 / /i INFILTRATION BASIN PARKING & LOADING O Q�4��`L / _ PMIN. # OF STALLS-CONVENIENCE STORE § 280-78(a) 1/100 GFA � � / J / END PROP. FENCE ® O AT EXIST. PROFESSIONAL ENGINEER 28 OSTAILLLSO o (01 ® / / VEGETATION LINE NEW YORK LICENSE No. 082537 MIN. OF STALLS-OFFICE § 280-78(a) 1/100 GFA- ��� UNLESS APPROVED BY ALL AGENCIES HAVING # J �� PROP. 6 H 2,106 100 ` O O� 3 R lo SOLID PVC JURISDICTION, THESE PLANS ARE NOT TO BE UTILIZED / `' / / FOR CONSTRUCTION. OWNER/ CONTRACTOR ARE P RESPONSIBLE FOR CONFIRMING ALL REQUIRED AGENCY 22 STALLS y OOP �`� / ® FENCE ALONG R APPROVALS HAVE BEEN SECURED PRIOR TO MIN. # OF STALLS-GAS STATION § 280-78(a) 1/EMPLOYEE = o ` �`� / J,�.`' EXIST UTILITY POLE PG COMMENCEMENT OF WORK, WHETHER DESCRIBED ON g GALS TO REMAIN OFO THESE PLANS OR OTHERWISE. 53 STALLS 36 STALLS (INCL 2 ADA + FAG y ar• / PROP. 'STOP" SIGN , r, C) 4 O 12 LANDBANKED STALLS* / FACING SOUTH PROP. 20 x41 �!� ,c� o REVISIONS LOADING STALL or. 0^ / ,�ti� �y REV NO. DATE REVISION MIN. STALL SIZE: § 280-78(c): 9 x19' 9 x19' o ° s• •a 12 � 151, 1 1012412J MISC. REVS MIN. LOADING STALLS: § 280-79(A)3: 4,906 SF < 5.000 SF N/A o PROP. SAWCUT & ASPHALT �PF�`\o © PROP. LOADING RAMPS o PAVEMENT REPLACEMENT , LEGEND 2 512JI24 PER TOWN COMMENTS / a PROP. 10 x20 x6 H MIN. # OF STREET TREES: § 280-93: 1 / 40' LOT FRONTAGE: 14 STREET TREES* (NYSDOT ITEM / ° ( MASONRY TRASH (ALL ITEMS EXISTING TO REMAIN UNLESS NOTED OTHERWISE) 1,077.93' / 40' = 27 TREES 1203.50140363) P 3 712JI26 REV S17F LAYOUT G © ENCLOSURE ON o` PROP. CONC. CURB RAMP © CONIC. MAT PROPERTY LINE FRONT LANDSCAPED AREA: § 280-93(B): 25' ALONG FRONT LOT LINE MAIN RD. (NYS 25) (NYSDOT TYPE 1 25.0' CONFIGURATION W/ / GJ HATCHED AREA °H OLD MAIN RD. � © OVERHEAD LINE OPTION C: CURB RETURN ° /' s �` cn 10.0'* & OPTION 2 DETECTABLE . '/ y• Q DEPICTS ALLOWABLE ( UTILITY POLE BUILDING ENVELOPE FRONT LANDSCAPED AREA: § 280-93(B): LANDSCAPE AREA OF 5' WIDE NONE PROVIDED* WARNING PLACEMENT) / �' t 25' -� GUY WIRE BABUTTING UILDING THE FRONT OF THE o (TYP. OF 4) ® �> .c�aw� (TRASH PROP. CONDENSING ® INLET o� m / s"" 2.5 R n ENCLOSURE) UNITS ON CONC. MAT LANDSCAPED PARKING AREA: § 280-95(A): 10 SF INTERIOR LANDSCAPE NONE PROVIDED* + ��15p'C / 'r 5 ° r��,p, 'rcp� �S y N SIGN AREA/ PARKING SPACE .yp ���1 / 3 R ' ` M .o ° , A� f , E�, /gn l / ' CONCRETE CURB 10 SF x 53 SPACES = Q * O PROP. STOP SIGN J � � p0 ,� e 530 SF o QUO �'ti / I ` FACING SOUTH Og a�{ , La PROP. CONC. s 1 ti PROPOSED CONCRETE CURB * INDICATES VARIANCE REQUIRED EXIST. ID SIGN TO BE * / / �, O CURB (TYP.) F % PR BUILDING RY ' _ PROP. TRASH / r, a'" „N N/O/F - PROPOSED FLUSH CONCRETE CURB REMOVED / RECEPTACLE yo,0 O (4,906 SF G.F.A.) STANLEY J. FLISS JR. EXIST. PROPANE / (TYP. OF 2) J \ �wy� v & JANICE M. FLISS PROPOSED AREA LIGHT W/ SHIELD STORAGE CAGES 33'R � PROP. 2,263.2 SF ''�' \�y 451;,ell / %< '-�-'� -;� ZONE: GENERAL BUSINESSCANOPY OVER B PROPOSED WALL MOUNTED AREA LIGHT TO BE RELOCATED ,3�R °� R /100 FRONT YARD SETBACK USE: RESIDENCE ( ) CONIC. FUELING MAT -1st FLOOR� z,t3o0 SF y^ + PROPOSED CONCRETE PAVEMENT 10'R � Q1 ��., � CONVENIENCE STORE/ � > THE EDUCATION LAW OF THE STATE OF NEW YORK PROHIBITS ANY PERSON ALTERING ANYTHING ON THESE DRAWINGS AND/OR THE �+ (� RETAIL AREA: 1,10 SF -1 ACCOMPANYING SPECIFICATIONS, UNLESS IT IS UNDER THE J PROP. SINGLE 'tiro O VIV � O O -2nd FLOOR 2,106 SF `J , PROPOSED GRASS AREA IN R.O.W. DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. WHERE SUCH FIXTURE AREA O O r<` OFFICE AREA: 1,868 SF 25 ALTERATIONS ARE MADE, THE PROFESSIONAL ENGINEER MUST SIGN LIGHT W/ OVA STAIRWELL AREA: 238 SF ' •• �tp (BLDG.) AND SEAL, DATE AND DESCRIBE THE FULL EXTENT OF THE 6�' • � SHIELD (TYP.) O 9 (NO BASEMENT) 4r �, l PROPOSED ASPHALT PAVEMENT IN ALTERATION ON THE DRAWING AND/OR IN THE SPECIFICATIONS. O ,}`� �5• �, �° d ® NYSDOT R.O.W. (NYS EDUCATION LAW SECTION 7209-2) / a, s. 8'R EXIST. MANHOLE COVER O O `G� (` PROPOSED ASPHALT PAVEMENT IN PROP. 5 WIDE - \ TO BE REMOVED s�., r ,y " �` `� LINE OF PORTICO/ ROOF � � ,.; /• �� TOWN R.O.W. CONIC. SIDEWALK / ww '' \ r�, ds OVERHANG (TYP.) (NYSDOT ITEM ° PROP. RELOCATED / PROP. U-BOLLARD (TYP.) - - - - - - - - - 12 PROPOSED PARKING STALL COUNT �so8.o1000010) �,G POLE °� o V,. (TYP.) s SHADED AREA O \� �' Ql r'' END PROP. FENCE ` p PROPOSED SOLID PVC FENCE / '• ° j DEPICTS PROPOSED0 AT EXIST. STORMWATER; s. \ \ `G J ° VEGETATION LINE PROPOSED SIGN O " C�Q�M D WMDD /:: '_� _ PROP. 8'X19' ADA PROPOSED PIPE BOLLARD INFILTRATION BASIN 'l © NOV 1 6 2026 •`-`, � � E ' ° 'L Cyl O PROP. BICYCLE PARKING SIGN � � PARKING LOADING � 00 PROPOSED INLET MOUNTED TO POST (MUTCD D4-3) 9' O STALLS N PROP. 3'X5' CONC. ' ® PROPOSED SOLID COVER SOUTHOLD TOWN ��L��� / �� / •I I I ° N�Q, GUARDRAIL TO ISLAND W/ (1) MPD / ' ' ' U ` o PROPOSED FLAG POLE PLANNING BOARD PROP. CONIC. CURB QO / I O ` . PROP. INVERTED U BICYCLE O \�G REMOVED (TYP. OF 4) RACK ON CONC. PAD Q o LIMIT OF VEGETATION (NYSDOT ITEM 'L Q� rn �609.0401) (TYP.) 6 / / PROP. LOCATION OF--�v ' \ .y 6 ( ) o PROPOSED BIKE RACK E j PROP. BRICK ° DISCHARGE PIPE &: I 1 R v '`: 3 m PROPOSED U-BOLLARD ENCASED CANOPY ° PROP. 20,000 0 6 ® PROPOSED AIR STATION GRAVEL PIT IN G-T °- _ SITE ADDRESS PROP. GRASS AREA (NYSDOT �'� NInLTRATION BASIN COLUMN (TYP. OF 6) a GALLON DOUBLE , ' ' cV o ITEM #610.16010020) (TURF / o /• / •� : I PROP. VACUUM O WALL FIBERGLASS - to PROPOSED VACUUM STATION UNDERGROUND m PROPOSED CONVENIENCE STORE ESTABLISHMENT;) (TYP.) / ` STATIONS ON J \ CONC. PEDESTALS z w STORAGE TANKS O PROP. RELOCATED o o e � C oo UNDER CONC. MAT PROPANE-CYLINDER ' v WITH FILLING STATION / ° ° •�• EXIST. DISP. ON * I I I \ 5'R EXCHANGE CAGES N W PIPE BOLLARDS • CONC. ISLAND TO \ EXIST. AREA \ ° / BE REMOVED 6 LIGHT TO BE ®a O "` I,..- 7400 MAIN ROAD (TYP. EXIST. BUILDING�I REMOVED • ■ ��` LINE OF EXIST. F.9edlc3(Grata 'cL' ( of s) \ .°< I Q PROP. STOP SIGN ?S o DENSE VEGETATION P ,''. ` MATTITUCK PROP. CONC. CURB RAMP (0 BE REMOVED _ ,, o / 1,600 SF) -0� FACING NORTH � �, � TO REMAIN _ _ c TOWN OF SOUTHOLD (NYSDOT TYPE 1 CONFIGURATION/ r� ,r, / / . 'v>, .� .� ��..�-. � � .;,•' . � . . . � `e..:'.�..;= :�. :�.''� . . . . � / y / / , L-- ;4Dr� _ SUFFOLK COUNTY, NY 11952 W OPTION A: FLARED CURB & % . - :Qfl' 'JN 87:`� PROP. AIR / / 7.1 / 197:a`4 �;II O VJ n Vw OPTION 1 DETECTABLE R / :VACUUM F 0 WARNING / PROP. LANDSC P s. AE Q s m :E�': •STATIONS PLACEMENT ON / AR ---.EA TYP. . DIS'� �` �`• . . TRICT•�• 100 0( ) PROP. 30 BLOCK: P LOCK'fi at . 07 o Dental t to r EXIST. 'CO C " Ca N PEDEST _ N SOOT I ALES Y ITEM 608.010500009 ( ) •a. OVERHEAD WIRE` 'CURB CUT � ° 'f, `a 'TO BE REMOVED` 1 / .r.../ MEET EXIST. GRADE/ SECTION: 122 LOTS: 1 & 3.2 _ - ..L= - ROADWAY FLUSH PROP. GRASS AREA `�� - +.. / 1 IN R.O.W. (TYP.) / �' Ct9r.ClOnai f's SCALE. 1 =20' HPE EMP021-01 °* O / ` C3. / - / _�� j" / PROP. GRASS PROP. SAWCUT & ASPHALT A Elmer's Custom ' �. /1 / •�" PAVEMENT REPLACEMENT PER TOWN Amish Furniture i" ''' �b DATE: 10/9/23 DWG ' EMP021-01-SP.3a ;,00y AREA IN R.O.W. OF SOUTHOLD REQUIREMENTS TYP. / � !` `� ' :I�'• _ -- / ��, �" PROP. CONC. CURB PER TOWN OF (TYP, (TYP.) DRAWN BY LD CHECKED BY. CT / ,:�' ;4' .�.` '.�©. . . �' . . . . . y SOUTHOLD REQUIREMENTS ) 169.8' ' • �� � / �,� L1 EXIST. EX/sT. urrcr7r D FREESTANDMNG POLE TO REMAIN Go1if• lD/PRICE SIJGN 1- oy H ',wind Farm • TO REM Time REMAIN untryine GpcG=.k `� EXIST. MONITORING WELL TO BE REMOVED C (TYP. - SEE GENERAL di C ° NOTE 9) TRAFFIC FLOW �- SITE TE PLAN / EXIST. TANK VENT PROP. CONIC. CURB PER TOWN KOAD 0 C'r 5j OF SOUTHOLD REQUIREMENTSOLD MAIN '"" � �' -" .. . . . . . . . . RISERS TO BE REMOVED GRAPHIC SCALE �, s (TOWN JURISDICTION) Vu �,lEXIST. DOUBLE WALL/� EXIST. AREA LIGHT TO 20 0 a0 20 . Laurel Links P�� 2'R BE REMOVED CFIBERGLASS UNDERGROUND TRAFFIC FLOW V a NEST NO • -w i� °r EXIST. FLAG POLE TO STORAGE TANKS TO BE6- OuntrY Club EXIST. PAVEMENT BE RELLOCATED REMOVED SNEIY IS N V=IINOSRM DIG.EVERY TIME. 'k . / � s* \ r D STRIPING TO BE ✓ -EXIST. MASONRY ( IN FEET ) THE STATE OF NEW raPoc WOLNES Cora BY 7W EA WS KEY MAP oEswrns oe,wr ACE AN w•rMn+xs ro STATE of�wnrs REPLACED PLANTER TO BE 1 inch = 20 ft. ,,,, �M�� IN-KIND (NYSDOT REMOVED ,� T �r����, N.T.S REV. 3 OF 10 ITEM f619.002 M�t1iCr+lGraUIT, ` ,;`a DRAINAGE CALCULATIONS: I „r RUNOFF COEFFICIENTS: DRAINAGE STRUCTURE SCHEDULE PAVEMENT = 1.00 STRUCTURE STRUCTURE RIM/ GRATE TOP/ BOTTOM INVERT INVERT EFFECTIVE HIGH m Y ID ELEVATION OF STRUCTURE IN OUT DEPTH (FT) Mill f on I I ; ROOF = 1.00 ' POINT A-1 PROP 8,578.9 CF INFILTRATION BASIN GR 16.00 20.00 15.00 15.00 --- 5 LANDSCAPE = 0.30 A-2 4'0 CATCH BASIN W/ INLET GRATE GR 20.15 --- 17.00 17.00 --- --- T7t t Llantal Cara of I,1;3YtitUt:k I / � �m SITE AREA = 63,308 SF A-3 4'x4' CATCH BASIN W/ CURB INLET GR 20.25 --- --- --- 17.00 --- I ENGINEERING A-4 4'x4' CATCH BASIN W INLET GR 20.10 --- --- - 16.85 j / -- --- RdcDcT�aatrl's�'a3 I� B-1 PROP 2,843.9 CF INFILTRATION BASIN GR 17.00 19.00 17.00 17.00 --- 2 Efmr_-r's Covtom 0, GROUNDWATER WAS ENCOUNTERED B ELEV. 4.1 (17'f DEEP) B-2 4'x4' CATCH BASIN W/ CURB INLET GR 18.85 --- --- --- 15.60 --- Amish Fumiru Y r`f �'� � I I II I 1860 WALT V'i1HITMAN ROAD B-3 PROP. 10'0 DRYWELL W/ SOLID COVER R 19.50 17.83 7.83 16.08 16.08 10 VOLUME REQUIRED = AREA X RUNOFF COEFFICIENT X 2" Ays B-4 PROP. 10'0 DRYWELL W/ SOLID COVER R 20.50 18.83 7.83 15.92 15-92 10 I�"I I � / �{ SjJITE 600 1GuIi L SYSTEM TRIBUTARY AREA (SF) VOLUME (CF) PROVIDED VOLUME (CF) EQUIVALENT B-5 PROP. 10'0 DRYWELL W/ SOLID COVER R 21.50 19.83 7.83 15.75 10 I I iG 'd MELVILLE,NY 11747 RAINFALL (IN) a ° Fi Fn�Ind Farm (516)777-4320 FAX: (516)777-4321 entry Time Cycle L X •` A O G I TC 18.45 �� MEET EXIST. PAVEMENT 15,364.0 x1.0)Ox2/12= 2,560.7 .v ROADWAY/ CURB/ A ROOF 5,063.5 xl.0)Ox2/12= 843.9 4,381.4 8,578.9 CF OF PONDING (SEE CALCS THIS SHEET) 3.9 I' COAL. SIDEWALK/ ALL PHASES OF ENGINEERING DESIGN, TEST HOLE DATA �, G 1.60 FLUSH S SURVEYING,CODE CONSULTING, LANDSCAPING 19,536.E x0.3I0x2/12= 976.8 rs'y f � G,y,�` (TEST HOLE DUG BY McDONALD GEOSERVICES ON MAY 1, 2001) -� � M f�prro�,0� ZONING ANALYSIS&BID SPECIFICATION PAVEMENT 11,537.2 x1.0)Ox2/12= 1,922.9 - ek--._,,._ N/O/F B ROOF 0.0 xl.0)Ox2/12= 0.0 2,513.4 31063.01 CF OF PONDING (SEE CALCS THIS SHEET) 4.1 EL 21.3' ' �- �' - I 0 18.E J,J �L COPAM REALTY COMPANY (3) 10'0 DRYWELLS W/ 10' EFF. DEPTH LANDSCAPING 11,811.4 x0.3)0x2/12= 590.E BROWN LOAMY SILT ML _ / \ , �j� ti www.HPEng.com 1' ° - 19 TC 18.85 `�6. ZONE: GENERAL BUSINESS (B) Laurel Links ,r- 63,313 6,894.8 TOTAL = t3,694.5 CF 3.97x a• Country ` G BC 18.3 �. .. � ® rt s `�� USE: McDONALDS RESTAURANT PALE BROWN FINE TO MEDIUM SAND SP 0� / s 7_ ���:/ tK CHRIS M. TAR TA GLIA 151 PROVIDED DRAINAGE VOLUME IS IN ACCORDANCE WITH NYSDEC STORMWATER MANAGEMENT DESIGN MANUAL. PER SWPPP REQUIREMENTS, THE 100 YEAR/8.77IN DESIGN STORM VOLUME IS ACHIEVED UITILIZING INFILTRATION VIA INFILTRATION PONDS AND LEACHING STRUCTURES <.• i:•, KEY MAP AT AN INFILTRATION RATE OF 11.3 IN/HR PER NYS WEB SOIL 'SURVEY. THE TOWNS 2" REQUIREMENT IS EXCEEDED. N T.S STORMWATER INFILTRATION BASIN CALCULATIONS (A-1) STORMWATER INFILTRATION BASIN CALCULATIONS (B-1) TC 19 16 z z: AVERAGE END AREA METHOD CALCULATIONS: AVERAGE END AREA METHOD CALCULATIONS: .w BC 18.6E PALE BROWN FINE SAND SP / ',r Q782O® N _ 6.5 = 235.1 F AREA OF ELEV. 15 (A,5) 357.71 SF AREA OF ELEV 1 (A16,5) 0 S .<• .••• • � � / AREA OF ELEV. 16 (A16) = 812.99 SF AREA OF ELEV. 17 0t7) = 641.62 SF GROUNDWATER / AREA OF ELEV. 17 017) = 1,353.53 SF AREA OF ELEV. 18 (418) = 1,407.70 SF ENCOUNTERED :" h` / ' PR NGINEER AREA OF ELEV. 18 (A1s) = 1,955.33 SF AREA OF ELEV. 19 (A19) = 2,230.64 SF // / NEW YORK LICENSE No. 078209 AREA OF ELEV. 19 (A19) == 2,613.79 SF / / AREA OF ELEV. 20 (A20) 3,328.81 SF TOTAL VOLUME = E((AN+AN+1)/2)xHN+1-HN :,y:'..,`•: `� // G 19.14 , LAWRENCE D. O 'BRIEN TOTAL VOLUME = 3,063.01 CF EL 4.1 '`' 17 2' // G 19.20 `p / / TOTAL VOLUME - E((Arl+!}.1+1)/2)xHN+1-HN .�G•�' / •� TOTAL VOLUME = 8,578.9 CF TC 19.4 B-1 / O / •(G0 � TC 19.54 BC WATER IN PALE BROWN GENERAL NOTES: FINE SAND SP 1. P I TC 19.47 / O 1 / x Zr�l x 27� PROPERTY OWNER/ APPLICANT: NOTE: SEE SHEET SP-3 FOR SANITARY SYSTEM AND AMAC INC. & 535 OLD MAIN REALTY LLC P.O. BOX 547 SHEET SP-9 & SP-10 FOR SANITARY PROFILES, 24, /�� x LAUREL, NY 11948 ELEVATIONS & DETAILS 2. THIS PLAN REFERENCES: TC t9.53 PROP. 3'x3'x6" G 19.53 DEEP GRAVEL A SURVEY PREPARED BY: BC 19.03 / NATHAN TAFT CORWIN III '" �� PAD O DATED: 8/9/23 1� TC 20.065 TC 1s•ss TC 19.53 DISCHARGE / PROFESSIONAL ENGINEER 3. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF EXISTING TOPOGRAPHY AND UTILITY INVERT ELEVATIONS PRIOR TO COMMENCEMENT 20 --� eC 19.54k BC 19.0E BC 19.53 ® J / �o� O ,,ng i / 'IV � NEW YORK LICENSE No. 082537 OF ANY CONSTRUCTION. CONTRACTOR IS TO ENSURE 0.75% IMIN. SLOPE AGAINST ALL GUTTERS TO PREVENT PUDDLING. ANY G1' P y�' TC 20.08 PROP. 13 Lf 15'! � / / DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. BC 20.08 CPP O 1.4X' INV.16.50 '1� / UNLESS APPROVED BY ALL AGENCIES HAVING 4. LOCATION OF EXISTING AND PROPOSED UTILITIES ARE APPROXIMATE AND MUST BE CONFIRMED INDEPENDENTLY WITH LOCAL UTILITY ✓ B-4 / •2rzff JURISDICTION, THESE PLANS ARE NOT TO HAVING UTILIZED COMPANIES AND MARKED IN FIELD PRIOR TO COMMENCEMENTT OF ANY CONSTRUCTION OR EXCAVATION. UTILITY SERVICE CONNECTION o �1 / I -01--��� FOR CONSTRUCTION. OWNER/ CONTRACTOR ARE POINTS SHALL BE CONFIRMED INDEPENDENTLY BY THE CONTFRACTOR IN FIELD PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. O�� BC 19.TC 16 ` 8-2 0 / `� /� RESPONSIBLE FOR CONFIRMING ALL REQUIRED AGENCY CONFLICTS SHALL BE REPORTED IMMEDIATELY TO THE ENGINEER. Jl \ ' o / LEGEND APPROVALS HAVE BEEN SECURED PRIOR TO 5. THE SUITABILITY OF EXCAVATED MATERIAL FOR USE AS BACKIFILL SHALL BE DETERMINED BY THE SOILS ENGINEER. ` O �c�0 � TC 19.94 .� 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING AIND REPLACING ALL UNSUITABLE FILL WITH STRUCTURALLY SUITABLE O� TC 20.04 19 BC 19.44 "� ry x / / (ALL ITEMS EXISTING TO REMAIN UNLESS NOTED OTHERWISE) COMMENCEMENT OF WORK, WHETHER DESCRIBED ON MATERIALS. ALL EXCAVATED OR FILLED AREAS SHALL BE COWPACTED TO 95% OF MODIFIED PROCTOR MAXIMUM DENSITY PER A.S.T.M P ` 5 BC 20.04 GR 18.85 THESE PLANS OR OTHERWISE. TEST D-1557. MOISTURE CONTENT AT TIME OF PLACEMENT SHALL NOT EXCEED 2% ABOVE NOR 3% BELOW OPTIMUM. 4� ` ` 500 P�'� REVISIONS 7. PROP. PAVEMENT, CURB AND SIDEWALK SHALL MEET EXISTINIG FLUSH WITH NO TRIP HAZARD. !� o / / p PROPERTY LINE 8. THERE ARE NO VISIBLE WATER SUPPLY WELLS LOCATED WITHIN 150' OF PROPERTY. o� p TC 19.45 , 9. CONTRACTOR TO MAINTAIN MAXIMUM OF 2% SLOPE IN ALL DFIRECTIONS AT HANDICAP PARKING AREA, LANDINGS AND 2% MAX. CROSS R' G t` F // G 20.04 TC 20.10 TC 19.93 BC 18.95 O REV NO, DATE REVISION G o BC 19.60 BC 19.43 TC 19.76 / ,�� orm OVERHEAD LINE SLOPE / 5% MAX. RUNNING SLOPE ALONG ADA PATHS, IN COMPLIANCE WITH ADA REQUIREMENTS. e �PFF / BC 19.26 N c0 No 1 10 24 23 MISC. REVS 10. CONTRACTOR TO VERIFY EXACT LOCATION OF EXIST. SANITARY STRUOCTURES TO BE REMOVED. REMOVAL MUST BE PERFORMED BY APPROPRIATELY 1g / TC 20.10 �_ / UTILITY POLE / / LICENSED CONTRACTOR IN ACCORDANCE W/ SCDHS REQUIREMENTS AND APPROVALS. CONTRACTOR TO CONTACT SCDHS POLLUTION CONTROL y9'' ��o� G 20.10 BC 20.10 ?p 1 e, x e) e�lz� 2 5123124 PER TOWN COMMENTS DEPARTMENT MIN. 48 HOURS PRIOR TO REMOVAL/ ABANDONMENT. o F G ° ` 2LZ / -� GUY WIRE 11. EXISTING GRADES PER SURVEY PREPARED BY NATHAN TAFT CORWINI III LAND SURVEYOR, DATED 8/9/23. ALL GRADES SHOWN ARE BASED UPON g`; �� / TC 20.70 p / �1 3 712JI26 REV SITE LAYOUT NAVD 88 DATUM. EGG t TC 20.38 BC 20.20 TC 21.50 �-� ® INLET 12. REFER TO TEST HOLE DATA PREPARED BY BY McDONALD GUOSCIENCE DATED 5 1 01. TEST HOLE PERFORMED TO A DEPTH OF 24' g• BC 19.88 / 26.E / / / 22.0 BC 21.00 BELOW SURFACE ELEVATION. GROUNDWATER ENCOUNTERED 17.2' BELOW SURFACE ELEVATION OF ±21.30 NAVD88 (ELEV. = 4.10 / / / � ': �� TC 20.64 TC 21.67 SIGN NAVD88). yr ® ( BC 20.64 TC 20.64 '� BC 21.17 13. PER USGS LONG ISLAND DEPTH TO WATER VIEWER, DEPTH TIO GROUNDWATER ESTIMATED AT 1T BELOW SURFACE ELEVATION t20.80 O TC 20.74 Y� G 20.38 �,,+� �� GF 21.22 BCTC 20.83 PROPOSED AREA LIGHT NAVD88. GROUNDWATER DEPTH ESTIMATED AT ELEVATION t3.180 (NAVD88). BC 20.74 + 14. ELEVATION 4.10 (NAVD88) USED FOR DESIGN PURPOSES ANID HIGHEST EXPECTED GROUNDWATER CONDITION. BC 20.83 \ PROPOSED WALL MOUNTED AREA LIGHT TC 20.69 o g� G 20.44 IBC 20.8•:&i 0 C/o N BC 20.19 / `1 .:.' / \ ��'f` PROP. SEPTIC Q� 0 TC 21.50 I Q PROPOSED CONCRETE PAVEMENT ` SYSTEM (TYP.) i BC 1.00 PROPOSED GRASS AREA IN R.O.W. ��•� ,,y�'2j�'�'- / TC 20.68 / - c TC 21.79 21 ?'® ° 4, FF 22.00 ',` FF 22.00 °, o R O G•�,,p� BC 20.18 G 20.74 � .� G 21.60 a f BC 21.29 G 20.85 ., ® PROPOSED ASPHALT PAVEMENT IN y' • 4" G 21.75 NYSDOT R.O.W. / \ c1° TC 21.14 RD 19.33, G 20.80 .;,�� GR 20.10 `.. BC 2\64. \ G 22.50 PROPOSED ASPHALT PAVEMENT IN C 20 5 20.80 c21.70 ' �\�\\\ C/0 G 22.00 TOWN R.O.W. BC 20.9 A-4 "i - 24.2 SPOT ELEVATION ° FF22.00= � �� RD 19.00;', O C/0' TC 21.90 PROP. 10 LF `�, / : 1 !.;r°• r.C.19.15 TOP & BOTTOM OF CURB ELEVATIONS 15'! CPP 0 C/0 �• Ir BC 21.4 G 22.00 STORY � 1. � B.C.te.75 ec 20.32 C/o f BUILDING �' TC 20.82 1.OX MIN. � -- ;a;�r G 22.15 i w RD 17.37 N/O/F / BC 20.32 TC 20.75 PROP. 54 LF 6"! mow- (4,906 SF G.F.A. s' �" y RIM 21.03 RIM ELEVATION GR 20.25 CPP o t.ox y` & JANICE M. FLISS / + ) STANLEY J. FLISS JR. 21 C/o ' ' . - pJ�9�'h' A-3 � ����,: /"�:.%' �""�• �. -23- - CONTOUR BC 20.8E \ ` '' ` ` G 22.25 ZONE: GENERAL BUSINESS B THE EDUCATION LAW OF THE STATE OF NEW YORK PROHIBITS ANY ti TC 21.40 TC 21.47 \ S" .er,- \ \ t PROP. ASPHALT BC 20.90 BC 20.97 �\ _1+? -1, y C/o USE: RESIDENCE ( > 23 PROPOSED CONTOUR PERSON ALTERING ANYTHING ON THESE DRAWINGS AND/OR THE TC 22.33 Ff22.00 PAVEMENT TO TI 21.3 \�2Q.B `'•.�, a i / TC 21.40 TC 21.20 T BI 20.8 , BC 21.83 G 22.00= � ''`; ACCOMPANYING SPECIFICATIONS, UNLESS IT IS UNDER THE - - MEET EXIST. 2L8 ` \ ' G 23.09 PROPOSED GRADE ELEVATION -rrrr BC 21.4 BC 20.70 L G 20.38 \ �� \. '". �RD 18.72 DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. WHERE SUCH -rrrr r ryyk°� / FLUSH (TYP.) PROP. 30 LF i5"! �021.¢ x C/0 / FF22.00= �. ALTERATIONS ARE MADE, THE PROFESSIONAL ENGINEER MUST SIGN 1rrr�-r �'� C/0 a _ `.� G 22.40 TC 23.97 PROPOSED TOP & BOTTOM OF AND SEAL, DATE AND DESCRIBE THE FULL EXTENT OF THE rr rrrrrr rr °I° CPP 0 1.tX G 22.00 x )_ Oi � CURB ELEVATIONS ALTERATION ON THE DRAWING AND/OR IN THE SPECIFICATIONS. rrr rrrrr r'rrrr rrrrrr r c/o C/p c/o /o \. \ F.F. ELEV= 22.00 - J % G ,n BC 23.47 / / C /` (NYS EDUCATION LAW SECTION 7209-2 r r r�rr�r rrr r ,",`�,.;:mot `.. TC 21.68 7C 21. TC 27.24 /o ` a �^'•' �' ) r� rrr rrr r- r r,.,;ce• " 21 TC21.90= FF 22.00 TF 22.00 rr rrrr rrrrr rr r -y. �� BC 21.18 BC 20.9 BC 20.74 C/o = -' \ TI 22.1E PROPOSED TOP & BOTTOM OF _ _ ro y� BC21.40 G 21.45' -, ISLAND ELEVATIONS C/o C o TI 21.31 \p` �" '�s BI 21.6E - -rrrrr-rrrr �- rrrrr r ,.,,,.: .- � %' - -rrrrr rr -i-,�. rrrrrrr '���-�.- / -r rrrr rr r'i-r rrrrrrr r A.°.;' rr ?'3-r rrrr rrrrr rrrrr rrrr rrrr / rt r� rrrrrr ,rrrrr rrrrrrr�r rrrrr �.� TC 21.45 C/p RD 18.89 gl 20.85 21 `\ TC21.90# FF22.00= / rrrr r� rrrrrrr rr rrr r rrrrr rrrrrrr G 21.20 RD 18.0 TF 22.00 PROPOSED TOP OF FOUNDATION rrrrr r rrrrrrr rrr rrrrrrr- rrr �1„- BC 21.45 BC�7.40 G 21.52 rrrrrr r rrr rr rrr r -rrrrrrrrr21.90 RD 18.89 G 21.10 � •' G 22.50 & GRADE ELEVATION *}-rrrrrrr r r A rrr rrrr rrrrrr rrrrrrr x .> PROP. 32 LF C/o G 21.13= TC22.13s FF22.00= --rrrrrrr r rrrr r rrrr r r-rrrrrr x 2L.3 BC21.63 = rHrrrrrrr rrrr r rrrrrrrrr �----- rrrrrrr rrrrrrr :1 � 6'! CPP TI 211.2 \, G 22.52 PROPOSED ROOF DRAIN INVERT rrrrrrrrrr�rrrrr r rrrrrrrrr r - rrr rrrrrr-r e• / 6r s BC 20.9 Z G� TC21.85• Frrrrrrrrrrrrrrrr- -rrrrrrr rrrrr rrrrrr :' O 1.OX MIN. TI 21.82 �% BI 20).75 \ �, 6' PROP. 172 LF rrrrrrrrrrrrrrrrrr rrrrrrr- rT i -rrrrrrr, ,I �' BC2t.85= " TP 23.09 PROPOSED TOP OF PAD ELEVATION rrrrr rrrrrrr rrrrrr rrrr rr rrt+:� TC 22.50 BI 21.32 r- --rrrrrrrrrrrrrrrrrr rrr rrrr r rrr -rrrrrrr „• / \ 6'! CPP O 1.1X rn rrrrrrr- rrrrrrr- rrr _ r r rrr rrrrr __ BC 21.50 TC21.91= G 23.20 PROPOSED GRADE ELEVATION rr rrr n r rrr.r rr G 21.98 C/0 g p rrrrrrrrj-rrrrrrr '-`� �� TC 21.65 TI 21.82 / ` BC21.91= rrr-�rr-rr•� F�rrr o / �� BC 21.15 x PROP. 200 LF 15`! BI 21.37 / TC22.41= TF 22.50 e• SW 23.78 PROPOSED SWALE ELEVATION rrrrrrr '� , = G 22.50 ti -rrrrrrr • 1 CPP 0 1.2X BC21.91 C/o 1 . . x RD 18.89 C/o BI 20).87 TC 22.60 y I 'rrr-•r�,•w" • °' G 1.81 C/o TI 21,.25 A_2 � .► PROPOSED FLOW ARROW n,/ •� c C/o BC 22.10 1Lff 2 4 TEST HOLE TEST HOLE LOCATION (SEE -TEST NOV I U 7FI26 OLD MAIN ROAD /G 22.30 ` 2L.7 RD 18.89 G 20.30 ?6 GR 20.i5 C/o HOLE DATA THIS SHEET) O ��--- TC22.48= SOUTHOLU ��e.:J PROP. 80 LF `C/0 BC21.98= F ( PROPOSED DRAINAGE PIPING W/ PLANNING BOARD�� STORMWATER TRIBUTARY AREA MAP / � j �` 6'0 CPP / G 2059 G 20.79 G 21.60= � SLOPE DIRECTION NISx G Z2 3 " �\Q j O 1.0% MIN. ' ' Q o NOTE: *- „� PROPOSED SANITARY PIPING W/ PROP. 3 x3 x6 DEEP TI 21.73 N w * SLOPE DIRECTION / TC 22.4t GRAVEL PAD o DISCHARGE BI 21.33 �; ow GRADES ® ACCESSIBLE PARKING AREA INV.15.00 (� & ROUTE TO CONFORM TO ADA W PROPOSED WATER SERVICE BC 1.9 X° '. A-t I I GUIDELINES (SEE GENERAL NOTE #9) SITE ADDRESS' G 22.6. `. � " X G 21.20 B� 21.23 I ti O E PROPOSED ELECTRIC SERVICE X 22 TC 22.88 N o , s . . PROPOSED SWALE W 22/ / 15 BC 21 88 c PROPOSED GAS SERVICE PROPOSED CONVENIENCE STORE titi 1617 22 i. 'TC 22.5s 9 ;► ITH FILLING STATION x 21.62 I. ;; BC 22.0E TC 22.24 0 „' 19 \ TC 22.67 TC 22.37 TC 1.95 BC 22.74 O N ir; 0 PROPOSED INLET 20 TC 22.66 BC 22.1 BC 21.87 BC 21.45 (fj ® PROPOSED SOLID COVER 7400 MAIN ROAD BC 22.1E a ' / G 22.68 22 G 23.20 "' OC/o PROPOSED CLEANOUT MATTITUCK ' TC 22.85 ® O .'?v N G 23.40 G 23.65 TOWN OF �SOUTHOLD x G 23.10 TC 22.9E BC 22.35 G 22.89 G 23.11 22 SUFFOLK COUNTY, NY 11952 22.4E ' - - 23 23 - `� E -E - - E - -E -� �'E -E E-� 25.3 TC 23.1 •y �� ,,....�. s �. �. �.�.���. '�" BC 22.E x22.1k x -87'.�22•' W:'ACT'.: : ti� ( : :'107;i`4' ` -- -25 SCDHS APPROVAL DISTRICT: 1000 BLOCK: 07 Tc 22.ss y 22.00 37'1:4.50 W' R O VAL BC 22. G 22.90 �C 22.84 ' 0 ..' G 23.00 TC 23.0E .... . 24 SECTION: 122 LOTS: 1 & 3.2 BC 22.34 =-= , G 23.00 B 2.5E 23 c 22 �' 23 C2 ?1 4 �;,5 CALF. 1" = 20' HPE _ 3'20 �- •®`• #• EMP021 01 G 2 .� 22�31 sQ+ / I 6 ` MEET EXIST. x �. 0 / 23 / DATE. DWG � •1 � GRADE ROADWAY 10 9 23 #` EMPO - - X 23.a2 / / / / �- TC 23.40 Tc 23.s2 FLUSH R4WN BY CHECKED BY / � ' / �� TC 22.89 TC 23.11 BC 22.90 BC 23.62 X2,10 LD CT / m ` x ZZ�Q ' TC 22.74 GR 22.15 SC 22.39 BC 22.61 N Tom. CG 23.28 / G 23.25 ®• .�� �� TC 22.92 BC 22.24 w /y emo �•` ;,� .�� BC 22.42 x 22 44Z G 23.50 S.`. ) �" GR 22.24 x PROP. 10'Ox10' DEEP / ,V 23.34 , 'y3 TC 22.93 0 ?� DRYWELL W/ INLET GRADING & y BC 22.43 GRATE IN R.O.W. x PROP. ASPHALT I ?3 ' ' � •�n • �+ •� '� � � PAVEMENT TO DRAINAGE PLAN G 23.60 / : :/ +� PROP. 10 0x10 MEET EXIST. PROP. 10'0x10' • �. GR 22.25 DEEP DRYWELL TRAFFIC FLOW G 23.68 x W CURB INLET FLUSH (TYP.) DEEP DRYWELL 22.91 IN R.O.W. W/ CURB INLET =' /,✓ BC 22.41x IN R.O.W. OLD MAIN ROAD GRAPHIC SCALE "' �.N.. TC 23.t3 (TOWN JURISDICTION) HEFT NO: 20 0 10 20 } BC 22.63 X '� / TRAFFIC FLOW SAFELY B N YOUR)N1�6.EVERY DIG.EVERY TIME.��/ TC 23.10 10 t/ x M STATE OF NEW YORK REOURES NOTInCATM BY EXCAVATORS, BC 23. o pESIGNM OR ANY PERSON FREPARMO TO DISTURB THE EARTHS SURFACE ANYWI ERE M THE STATE W p TC 23.3 1 inch FEE 20 )ft. NEW YORRK STATTE CODE ULE 753 BC 22.8 230 x PUBUC SERHCE COMMISSION, REV. 3 OF 10 oo SANITARY CALCULATIONS I/A OWTS SIZING SANITARY FLOW = 210.4 GPD I ur SANITARY DENSITY COMPUTATION GROSS LOT AREA 63,308 SF (1.453 AC) ' ,Q SCDHS GROUNDWATER MANAGEMENT ZONE = IV (600 GPD/AC) REQUIRED CAPACITY = 1 DAY x 210.4 GPD = 210.4 GAL. HIGH I r J TC 20.10 rBC C 19.45 POPULATION DENSITY EQUIVALENT = 1.453 x 600 - 871.8 GPD PROPOSED i/A OWTS HYDROACTION AN500-C (500 GAL. CAPACITY) TC 19.93 18.95 jml I - 19.60 TC 19.76 SANITARY DENSITY GREASE TRAP SIZING I POINT EXPANSION SANITARY B C 19.2 6 PROPOSED CONVENIENCE STORE (WET STORE W/ FOOD) & OFFICE SPACE (NON-MEDICAL _ i I BC 19.43 PROP. FUTURE 50'G KITCHEN FLOW = 336.0 GPD ' REQUIRED CAPACITY - 1 DAY x 336.0 GPD - 336.0 GAL. q LEACHING POOL OFFICE) PROPOSED (1) B' DIA x 5' LIQ. DEPTH GREASE TRAP (1,500 GAL CAPACITY) I I I I N ENGINEERING TC 20. 1 0 WET STORE W/ FOOD 0.03 GPO/ SF x 2,800 SF = 84.0 GPD I I G 0 10 BC 20.1 0 \ NON-MEDICAL OFFICE I = 0.06 GPD/ SF x 2.106 SF = 126.4 GPD SEPTIC TANK SIZING I I I 2 . 20 / O TOTAL SANITARY DENSITY 210.4 GPD KITCHEN FLOW - 336.0 GPD I j $-9 $ 1 SANITARY DENSITY = 210.4 GPD < 871.8 GPD, THEREFORE AN I/A OWTS DISPOSAL SYSTEM IS REQUIRED CAPACITY = 2 DAYS x 336.0 GPD = 672.0 GAL. I I I (MIN.) PERMISSIBLE FOR THIS SITE PROPOSED (1) SEPTIC TANK 8' DIA. x 4' EFF. DEPTH (1,200 GAL. CAPACITY) PROP. 1-1/2 II I I 1860 WALT WHITMAN ROAD TC 20.70f, SANITARY FLOW G� / / ► SUITE 600 WATER METER & 7--� PROP. PLC CONTROL LEACHING POOL SIZING CURB BOX (LOCATION;I I L1- MELVILLE,NY 11747 PANEL MOUNTED TO POST BC 20.20 WET STORE W/ FOOD = 0.03 GPD/ SF x 2,Sao SF = 84.0 GPD PER SUFFOLK COUNTY _ 126A GPD TOTAL DESIGN FLOW = 1.5 G GPD (516)777-4320 FAX: (516)777-4321 do FUJON 24"f� CONCOPAD � PROP. 8'0 TC 21 .SO NON-MEDICAL = 0.06 GPD/ SF x 2,106 SF = 210.4 GPD DESIGN HYDRAULIC LEACHING RATE = 1.5 GPD/SF � WATER AUTHORITY) �/ "� SEPTIC TANK BC 21 .00 REQUIRED LEACHING AREA = 546.4 GPD / 1.5 GPD/SF 364.3 SF / /I jI jj j✓z iG PROP. 10 ANITARY = EXIST. FIRE WELL TC 20.64 USE REQUIRED LEACHING POOL (31.41 SF/VF) PROP. CONNECTION TO / ALL PHASES OF ENGINEERING DESIGN ACHING POOL � $_7 PROP. 8'M KITCHEN FLOW EXISiff T. WATER MAIN , � REQUIRED DEPTH = 364.3 SF / 31.41 SF/VF = 11.6 VF Q $_6 GREASE TRAP BC 20.64 TC 20.64 N PROPOSED CONVENIENCE STORE (WET STORE W/ FOOD) PROPOSED (2) 10-0 LEACHING POOLS ® 6' EFF. DEPTH): I '\ S SURVEYING,CODE CONSULTING, 12.8' WET STORE W/FOOD - 0.12 GPD/ SF x 2,800 SF - 336.0 GPD = 2 x 31.41 SF / VF x 6 VF = 376.9 SF '` ° ZONING ANALYSIS&BID SPECIFICATION BC 20. _ a, (5 MIN.) `J G 21 .22 PROFILES ELEVATIONS & DETAILS I �s ti� COPAM REALTY COMPANY FF 22.00 64 L ' L NOTE: SEE SHEET SP-10 FOR SANITARY I I N101F \ S-8 �M�N•1 rays• TC 20.83 TOTAL HYDRAULIC FLOW 1g� 'o. , �,��/ www.HPEng.com ,r, p SANITARY FLOW = 210.4 GPD I I / �, " s'Q, 0'.��/ ZONE: GENERAL BUSINESS (B) BC 20.83 KITCHEN FLOW = 336.0 GPD TC 21 .34 yJ / \ TOTAL HYDRAULIC FLOW = 546.4 GPD �7 ?, *• �9y �S� /`ti USE: McDONALDS RESTAURANT CHRIS M. TARTAGLIA 9 S-5 C/0 ° ��;:;,' f titK BC 20.84 F s-3 � I /, / / X �a �� � NEW ro PROP. 3/4" SCH. 40-� .q \� TC 21 .50 / / f :{' I PVC PIPE (BLOWER LINE) ��- E S. PROP. 100 SANITARY ��1 �� s. G�. :. ' ,,, / LEACHING POOL 2 a [ yJ $-� \ a./ FF 22.00 , PROP.HRIP EATED 1 W PROP. 1/2" SCH. 80 PVC TG 21 .79 PROP. tI7 ° FF 22.00 ''' " G 21 .60 �� � { ENCLOSURE - HYDRO-ACTION �- , ON CONC. PAD T$24 PIPE (ELECTRIC LINE) ® i BC 21 .29 IA SYSTEM y °° ° G 20.85 ��- / 9 LS-4 / y� .. 0 �. p PROP. 4 0 VENT LINE TO �,� s• °° r. TC 21 .14 R D 19.33 � v TIE INTO BUILDING VENTING tiJ a.�',z- � �,, ° � ° c / / PR NGINEER t $_2 a� BC 20.64 ;i NEW YORK LICENSE No. 078209 TC 22.20 ° PROP. / BC 21 .7O \ \� PRE-TREATMENT TANK / / LAWRENCE D. O 'BRIEN 0000, C/o� TC 21 .9 0 F F 22.0 0* _ - ' : - R D 19.00 REPUTED LOCATION OF / / �'o• * _- EXIST. UNDERGROUND /' '�°' Y'` / / - - - _ - - BC 21 .40 i WATER N (1!I F.) x R D 117.371)( _ - loop Llv�L - - -- - _ _ W 20 �-� / 1 ' m PROFESSIONAL ENGINEER WORK AREA ���A�� J o / NEW YORK LICENSE No. 082537 i SCALE: 1" = 10' P � / INV.16.50 �° / / UNLESS APPROVED BY ALL AGENCIES HAVING ® PROP. 1-1/2"0 JURISDICTION, THESE PLANS ARE NOT TO BE UTILIZED NOTE: SEE SHEET SP-10 FOR SANITARY PROFILES/ DETAILS O �rL / ® UNDERGROUND M� FOR CONSTRUCTION. OWNER/ CONTRACTOR ARE \G��� o� \ DOMESTIC SERVICE LEGEND RESPONSIBLE FOR CONFIRMING ALL REQUIRED AGENCY WATO ALL ITEMS EXISTING TO REMAIN UNLESS NOTED OTHERWISE APPROVALS HAVE BEEN SECURED PRIOR TO GRAPHIC SCALE � �' `���' / � � a / ( ) COMMENCEMENT OF WORK, WHETHER DESCRIBED ON 19 N �/ THESE PLANS OR OTHERWISE. io o s io ��50�� / r`� `y / G� PROPERTY LINE REVISIONS 0 ��O / EXIST. UTILITY OVERHEAD WIRES REV NO. DATE REVISION / POLE do GUY WIRE s1 ( IN FEET ) �PFF c / TO REMAIN UTILITY POLE 1 10 24 23 MISC. REVS 1 inch = 10 ft. oya / �' / a0'� / �5� I / / o� S S -G GUY WIRE 2 5/23/24 PER TOWN COMMENTS Ada ( � INLET � REMAIN (SEE NOTE 9) ® SIGN 3 7/23/26 REV SITE LAYOUT ( ) GENERAL NOTES' PROP. UNDERGROUND GAS / e / ® -p PROPOSED SERVICE. CONTRACTOR TO �.�� ©� V P ED AREA LIGHT 1, PROPERTY OWNER/APPLICANT: o COORDINATE WITH NATIONAL GRID ^ P.O. INC. & 535 OLD MAIN REALTY LLC FOR INSTALLATION PROPOSED WALL MOUNTED AREA LIGHT ti �� C/0 PROP. SEPTIC SYSTEM. � PROPOSED CONCRETE PAVEMENT P.O, BOX 547 / o " / / � , LAUREL, NY 11948 / ti / o (REFER TO WORK AREA 2. THIS PLAN REFERENCES: A SURVEY PREPARED BY: / / / a DETAIL THIS SHEET) PROPOSED GRASS AREA IN R.O.W. NATHAN TAFT CORWIN ill 21�- 21 DATED: 8/9/23 O + \ ,,.' \. �\ ® PROPOSED ASPHALT PAVEMENT IN 3. LOCATIONS OF EXIST. STRUCTURES/ UTILITIES ARE SHOWN PER REFERENCED SURVEY & i • NYSDOT R.O.W. REPUTED LOCATON OF EXIST �.•,•.. INFORMATION AVAILABLE AT TIME OF PREPARATION OF THIS PLJAN. CONTRACTOR SHALL VERIFY ''� e> GAS MAIN (PER MARKOUT) / ;�._ 1 PROPOSED ASPHALT PAVEMENT IN TOWN EXISTENCE, LOCATION AND DEPTH OF ALL STRUCTURES, LIST'S„ PIPING, DRYWELLS & UTILITIES IF / AT TIME OF CONSTRUCTION. N ) ~`^' \ PROP• R.O.W. 4. ENGINEER NOT RESPONSIBLE FOR CONTRACTOR'S SEQUENCING, PLANNING OR EXECUTION OF / / " •� c/o " ELECTRIC THE WORK DEPICTED ON THESE PLANTS. y,�+ j. � ./'. � � / METER - -23- - CONTOUR 5. ENGINEER OF RECORD NOT RESPONSIBLE FOR PREPARATION, MONITORING OR REVIEW OF I PROP. 2 STORY '� "'" 23 PROPOSED CONTOUR CONTRACTOR'S SITE SAFETY PLAN. CONTRACTOR ACKNOWLEDGES THAT COMPLETE / C/o Q I`' ,,�.a , RESPONSIBILITY FOR JOB SITE SAFETY LIES WITH HIMSELF AND THOSE PARTIES UNDER HIS c/o - BUILDING DIRECTION. ,� ) _-: \ \, `. N101E PROPOSED DRAINAGE PIPING W/ / % (4,906 SF G.F.A. 6. OWNER/ CONTRACTOR RESPONSIBLE FOR OBTAINING ALL REQUIRED UTILITY DISCONNECTIONS. REPUTED LOCATION OF EXIST. WATER _ �__ STANLEY J. FLISS JR. ' SLOPE DIRECTION 7. CONTRACTOR TO INSTALL SHORING/ BRACING DURING EXCAVATION AS REQUIRED PER OSHA SERVICE do WATER METER TO BE CUT 7- Zi c/o �- � `' ,` . ' & JANICE M. FLISS STANDARDS. AND CAPPED AT PROPERTY LINE AND ti, ` % ` - v `� " PROPOSED SANITARY PIPING W/ 8. CONTRACTOR RESPONSIBLE FOR NOTIFYING SCHEDULING INSPECTIONS W APPLICABLE ABANDONED IN PLACE i ZONE: GENERAL BUSINESS B THE EDUCATION LAW OF THE STATE OF NEW YORK PROHIBITS ANY / / , O SLOPE DIRECTION AGENCIES. "• c/o USE: RESIDENCE PERSON ALTERING ANYTHING ON THESE DRAWINGS AND/OR THE 9. CONTRACTOR TO COORDINATE W/ ENVIRONMENTAL CONSULTANT' TO CONFIRM IF EXISTING / T -1st FLOOR 2,800 SF •.. W PROPOSED WATER SERVICE ACCOMPANYING SPECIFICATIONS, UNLESS IT IS UNDER THE MONITORING WELLS DISTURBED/ REMOVED DURING CONSTRUCTIION MUST BE REPLACED. / LE ) CONVENIENCE STORE/ ' , I DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. WHERE SUCH 10. IT IS THE OWNERS CONTRACTORS RESPONSIBILITY TO ENSUIRE ALL REQUIREMENTS C/0 RETAIL AREA: 1,231 SF �' E PROPOSED ELECTRIC SERVICE ALTERATIONS ARE MADE, THE PROFESSIONAL ENGINEER MUST SIGN / / C/0 � " � ., � 4, � AND SEAL, DATE AND DESCRIBE THE FULL EXTENT OF THE STIPULATED WITHIN THE 2020 EXISTING BUILDING CODE OF NYS CHAPTER 15 CODE �� -=-_ -2nd FLOOR 2,106 SF ; C/0 C/0 c/o C/o °�� - -_ _J G PROPOSED GAS SERVICE ALTERATION ON THE DRAWING AND/OR IN THE SPECIFICATIONS. §1502.1 & THE 2020 BUILDING CODE OF NYS CODE §3307.1 ARE ADHERED TO. / / \ C/o "- OFFICE AREA: 1,868 SF n (NYS EDUCATION LAW SECTION 7209-2) 11. ALL STORMWATER DRYWELLS BEING REMOVED OR ABANDONED IIN PLACE MUST COMPLY WITH �/ C o ® 21 STAIRWELL AREA: 238 SF �: /° i}11 0 PROPOSED INLET USEPA UNDERGROUND INJECTION CONTROL PROGRAM REQUIREWENTS. / �O / C/o (NO BASEMENT) 12. PRIOR TO THE ABANDONMENT OR REMOVAL OF A COMMERCIAL ON-SITE SANITARY SYSTEM, A EXIST. OVERHEAD WIRES TO BE Copy° C/o REMOVED CONTRACTOR TO 1. C/0 4 E��tL' `- ® PROPOSED SOLID COVER WORKPLAN MUST BE SUBMITTED TO THE DEPARTMENT FOR REVIEW AND APPROVAL. ( `L 21 �• §�=fit p\� �. �•. 13. THE EXISTENCE / LOCATION OF SANITARY STRUCTURES HAS MOT BEEN CONFIRMED. ALL COORDINATE WITH UTILITY ON-SITE SANITARY STRUCTURES AND LEACHING POOLS SHALL BE REMOVED, ABANDONED, OR COMPANIES FOR REMOVAL) / r. . C o TEST HOLE TEST HOLE LOCATION (SEE "TEST REPLACED MUST BE PUMPED EMPTY AND HAVE A SAMPLE COLLECTED FROM THE BOTTOM / / / / J „A t, a> �. ° ' HOLE DATA", SHEET SP-2) SEDIMENT OF THE LEACHING POOL. THE BOTTOM SEDIMENT SAIMPLE MUST BE ANALYZED FOR VOLATILE ORGANIC COMPOUNDS (VOC'S) BY THE EPA METHOD 8260, SEMI-VOLATILE ORGANIC �, r� PROP. GAS METER COMPOUNDS (SEMI-VOC'S) BY EPA MI=THOD 8270, AND 8 RCRRA METALS BE EPA METHOD / UTILITY CROSSING NOTES: 6010 BY A NEW YORK STATE DEPARTMENT OF HEALTH CERTIFIIED LABORATORY TO DETERMINE / o --� \ C/o IF REMEDIATION IS REQUIRED PRIOR TO FINAL CLOSURE AND BACKFILLING THE LEACHING POOL / c 1. THE CROSSING OF WATER AND SANITARY LINES SHALL BE AS FOLLOWS: NOV 16 2026 WITH CLEAN SAND. ti~ 1.1. SANITARY LINES SHALL BE LAID BELOW THE WATER LINE WITH A SEPARATION OF AT LEAST EIGHTEEN s / / c/o 1/0 C/o INCHES BETWEEN THE BOTTOM OF THE WATER LINE AND THE TOP OF THE SANITARY LINE; AND SOUTHOL.D To`"NN C/o �' O tix' 1.2. SANITARY LINE JOINTS SHALL BE AT LEAST TEN FEET FROM THE POINT OF CROSSING. PLANNING BOARD C/o ?s 2. WHEN LOCAL CONDITIONS PREVENT PLACEMENT OF THE WATER LINE ABOVE THE SANITARY LINE, THE `c/o0� 2 1 FOLLOWING E TICALDISIONAL EPARATIONDOFONS APPLY: AT LEAST EIGHTEEN INCHES SHALL BE PROVIDED BETWEEN THE BOTTOM �// z - H- OF THE SANITARY LINE AND THE TOP OF THE WATER LINE; AND Q o 2.2. WATER LINE JOINTS SHALL BE AT LEAST TEN FEET FROM THE POINT OF CROSSING; AND I ey w 2.3. SANITARY LINES SHALL BE CONSTRUCTED OF MATERIALS AND JOINTS THAT ARE IN ACCORDANCE INV.15.00 \ a o WITH WATER MAIN STANDARDS OF CONSTRUCTION AND SHALL BE PRESSURE TESTED TO ASSURE II 3 WATER TIGHTNESS PRIOR TO BACKFILLING. / I ° SITE ADDRESS 22No 0 3. ALL EXISTING AND PROPOSED UTILITY LOCATIONS ARE APPROXIMATE. CONTRACTOR IS RESPONSIBLE FOR ALL UTILITY COORDINATION, INCLUDING FILING APPLICATIONS AND DETERMINING POINT OF ENTRY WITH PROPOSED CONVENIENCE STORE 22 o 16 APPROPRIATE UTILITY COMPANY. / ti P 17 22 WITH FILLING STATION 18 19 / 0 4. IF GREATER SEPARATION IS REQUIRED/ RECOMMENDED BY OWNING UTILITY COMPANY, SAID COMPANIES RECOMMENDATION SHALL DICTATE. 7400 MAIN ROAD 20 N 5. IN NO EVENT SHALL WATER LINES BE INSTALLED SHALLOWER THAN 4' BELOW GRADE. MATTITUCK, ® O 22 t;�a k 6. IF SITE CONDITIONS PROHIBIT THE ABOVE SEPARATIONS, CONTACT ENGINEER OF RECORD IMMEDIATELY IN TOWN OF SOUTHOLD , - WRITING. SUFFOLK COUNTY, NY 11952 23 _ * 23 _ {... -E E E E E ,.: E EE E �. 5 �-��8 2 S C D DISTRICT: 1000 BLOCK: o / '87'14''S0` :; `137:a'4 HS APPROVAL o7 . � 24 23 i i SECTION: 122 LOTS: 1 & 3.2 / 2 .3 / 3 .2 �- :'w. CAE AS H''� .®': Sal 1 SOWN HPE _ s EMP021 01 / es / :a 2 8 / 3 �..� P/ �. . i DATE•1 .� DWG / / a 10/9/23 #' EMP021 01 SP.3a �p DRAWN BY.• LID CHECKED BY.• CT EXIST. MANHOLE TO REMAIN (V.I.F.) B EXIST. UTILITY POLE TO REMAIN PROP. UNDERGROUND ELECTRIC & TELECOM SERVICES. (CONTRACTOR TO EXIST. OVERHEAD WIRES TO BE COORDINATE WITH OWNING UTILITY / / `•' ��.`.' ` /�� /� COORDINATE WITHCONTRACTOR TO 0 OWNING UTILITY COMPANIES FOR INSTALLATION) . UTILITY/ SEPTIC EXIST. MONITORING COMPANIES FOR REMOVAL) ' ° Saf 'y. a Yor WELL TO REMAIN SYSTEM PLAN (TYP.- SEE NOTE 9) TRAFFIC FLOW 1 . 000 MAIN ROAD OLD GRAPHIC SCALE ^: (TOWN JURISDICTION) SHEET NO: zo 0 o zo / TRAFFIC FLOW before you i ( IN FEET ) 1 inch = 20 ft. REV. 3 OF 10 AREA OF SITE , CONSTRUCTION "Y�i' ,•, •" '`-�� ,•°A . � � ry,. AREA WITHIN PROTECTION �w�• ZONE/ TREE DRIP' LINE FENCE O HIGH �, Q TO FOLLOW TREE DRIP LINE PLANTING LIST OR 6' FROM TRUNK- WHICH •' EVER IS GREATER 4' WOOD & Mature POINT WIRE SNOW FENCE W/ STEEL Quantity Symbol Botanical Name Commlon Name Size Spacing Height STAKES 18" O.C. I�P 7 PO PICEA ORfENTALIS ORIENTAL SPRUCE 1 GAL 25' O.C. 50'-60' E ENGINEERING WOOD & WIRE SNIOW o FENCE USED AS TREE 7 CB CARPINUS BETULUS 'FASTIGIATA' HORNBEAM 15 GAL 20' O.C. 30'-40' GUARD TO PREVENJT DAMAGE FROM COINST. 36 TP = THUJA PLICATA GREEN GIANT 25 GAL 7' O.C. 40'-60' �a sue. 1860 WALT WHITMAN ROAD EQUIPMENT. ; ,'�; so. SUITE 600 AREA WITHIN TREE_ � * k j 8 BH BUXUX HYBRID BOXWOOD '(GREEN 7 GAL 3' O.C. 3'-5' MELVILLE NY 11747 PROTECTION ZONE TO I Q MOUNTAIN' 1 REMAIN UNDISTURBED PO - ORIENTAL SPRUCE TP - GREEN GIANT _ o (5 6)777-4320 FAX: (516)777-4321 DURING CONSTRUCTION -- FA ;;� � >� j --- FLOWERING ANNUALS -- -- - �' 1 CB � $ BH � NTS NTS TREE DRIP LINE/ TREE NOTES: 1. All planting beds to receive a minimum 8" layer of screened topsoil. / / ALL PHASES OF ENGINEERING DESIGN, PROTECTION ZONE ,,. 2. Planting beds are to receive 2" layer of shredded cedar rrnulch. I` SURVEYING, CODE CONSULTING, 4 WOOD & Y" PROP. GRASS WIRE show � ,� ZONING ANALYSIS &BID SPECIFICATION FENCE W/ STEED STAKES 8' O.C. STANDARD GRASS SEED MIXTURE':' ; '' AREA (TYP.) x -�� ,u--� www.HPEng.com �` Y VARIETY POUNDS/ POUNDS/ PROP. GRASS AREA (NYSDOT DURING ; AC 1.g00 SF ITEM #610.16010020 TURF TREE PROTECTION DURING 1, ( ,'" 'a , RE 1 PO T---T CHRIS M. TARTAGLIA BIRDSFOOT TREFOIL EMPIRE/ PARDEE 8 0.20 ESTABLISHMENT) (TYP.) �- .x SITE CONSTRUCTION ���' QR �>� NEB . COMMON WHITE COMMON 8 0.20 EXIST MAh' - - -- - _ CLOVER p D SEW �Q /t• �,� DENSE VEGETATION STANDAF�D CLAMPS r.- PLUS N PROP. TREE Ui - �- . TALL FESCUE KY-31/ REBEL 20 0.45 j� � '� I � r � 8,-0. GE SNOW FENCE # FENCE r (MAX.) PLUS } PROTECTION A REDTOP COMMON 2 0.05 O 1 p' LINE OF EXIST. STANDARD POLE BH - BOXWOOD FA - FLOWERING ANNUALS OR ' o \`� CB ` r DENSE VEGETATION n.. TO REMAIN 9782 SCAFFOLD S GREEN MOUNTAIN NTS RYEGRASS pENNFINE/ LINN 5 0.10 j�� �(I' I< A NTS (PERENNIAL) cy� , '� / PR NGINEER ZZ PROP. SIGHT PROP. GRASS NEW YORK LICENSE No. 078209 VISIBILITY LINE �� 1 AREA (TYP.) 1 0 DRIVEWAY i ® LAWRENCE D. O 'BRIEN 1 O � . GRADE (TYP.) iV FENCE C YREE P . PROTECTION FA -1 N.T.S. 1 r ---.,- Zr, O p0 O� PROFESSIONAL ENGINEER �ANEW YORK LICENSE No. 082537 o 1 PO 5 0 O� UNLESS APPROVED BY ALL AGENCIES HAVING CB - HORNBEAM `' �� d y FA °' 0 PROP. . JURISDICTION, THESE PLANS ARE NOT TO BE UTILIZED d d NTS j MULCH AREA N FOR CONSTRUCTION. OWNER/ CONTRACTOR ARE -' RESPONSIBLE FOR CONFIRMING ALL REQUIRED AGENCY d d REINFORCED RUBBER HOSE ® 0 (TYP.) APPROVALS HAVE BEEN SECURED PRIOR TO d (2) o 0 0 �j- COMMENCEMENT OF WORK, WHETHER DESCRIBED ON THESE PLANS OR OTHERWISE. d d /► 23 TP � � d DOUBLE STRAND WIRE #12 / PROP. GRASS O N REVISIONS GALV. TWISTED AREA (TYP.) 0 C° REV N0. DATE REVISION 1 1012412J MISC. REVS d 2- CEDAR OR LOCUST �>w STAKE - 2 5 23 24 PER TOWN COMMENTS 4, 3 7/23/26 REV SITE LAYOUT 6 1 - " TRUNK WRAPPING 1 CB s �` -� / Q MIN. PROP. SIGHT < = O o 3" SHREDDED BARK MULCH VISIBILITY LINE - p (NOT TO BE PLACED BY 0 DRIVEWAY ♦ , ���.. PROP. I ® I3I,II DINI(ORY M, o ROOT FLARES) TYP. ( ) ►FIN. GRADE ` (4,906 SIG.I'.A ) ;ti,- O STANLEY J. FLISS JR.N/0/F & JANICE M. FLISS �lQ• USE: RESIDENCE ' `� ZONE: GENERAL BUSINESS (B) 2 1�� I- 6" SAUCER 1 ` o, =_ �� < `' - R 2,800• o n�' g � 1 st FI00 SF � o I I CUT & REMOVE BURLAP FA CONVENIENCE STORE/ }C- 4' =III=I FROM TOP 1/3 OF BALL A / RETAIL AREA: 1,231 SF J / - ` O O 2nd FLOOR OOR 2,106 SF = I Ill III II-I III III III= =111; / O OFFICE AREA: 1,868 SF O STAIRWELL AREA 238 SF - / O 011, 11 -L=I1 I1=L- 1TOP SOIL & BACKFILL --- (NO BASEMENT)III-III-III.III I � ---_ _-�,, - PROP. GRASS AREA (TYP.) 9" BALL SPREAD 9" UNDISTURBED SOIL ` T, O ,�`' �� � jam`o� O� >1 i� �_ \o 0 o FA ♦ a � y�, DECIDUOUS TREE PLANTING DETAIL PROP. GRASS AREA (NYSDOT / - ♦ ` * PROP. TREE N.T.S. ITEM #610.16010020) (TURF PROTECTION - THE EDUCATION LAW OF THE STATE OF NEW YORK PROHIBITS ANY ESTABLISHMENT) (TYP.) O �� FENCE �/ PERSON ALTERING ANYTHING ON THESE DRAWINGS AND/OR THE EVERGREEN TREE O .� ACCOMPANYING SPECIFICATIONS, UNLESS IT IS UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. WHERE SUCH REINFORCED RUBBER 0 0 C T T T HOSE 3 GUYS OF # 12 Do O ��-.. ., - ,.-„„ _, ALTERATIONS ARE MADE, THE PROFESSIONAL ENGINEER MUST SIGN SYMBOL LEGEND AND EXTENT OF THE WIRE DBLE. STRAND O ALTERAFTION ONE THE°DRAW NGBAND/OR EINLTHE SPECIFICATIONS. (NYS EDUCATION LAW SECTION 72 9-2) GALVANIZED ANNEALED; - , ' � �' LOCATE AT 3 EQUAL s � O� � � INTERVALS AT BASE OF - / F j 1, LINE OF EXIST. (ALL ITEMS ARE EXISTING TO REMAIN UNLESS OTHERWISE NOTED) TREE 120 DEGREES APART %,, DENSE VEGETATION TOP OF ROOT BALL TO BE / 3 CB / ~ TO REMAIN I SYMBOL DESCRIPTION INSTALLED 2" ABOVE / SURROUNDING GRADE Q � Q LIj LIj CURB INLET 2" SHREDDED BARK MULCH ~f( o SOLID MANHOLE COVER [] El BACK FILL W/ TOPSOIL AND PEAT MOSS; 3:1 o A PROP RATIO BY VOLUME 4 PO oo MULCH INLET GRATE NOV©. ZOZf WATER UNTIL SETTLED j o AREA (TYP.) I� j LOOSEN SUBSOIL 8" MIN.; - o SCUDHNG BOARD DARN BACKFILL AND COMPACT � �� } � � I i I i o PROPOSED INLET PROTECTION PLANNING W/ TOPSOIL AND PEATI cn El SOLSRRTo DAMPEN / 16 TP � vaz IPIOROPINTI fir ir.Gi PROPOSED SILT PROTECTION LINE OF EXIST. (SEE DETAIL ON SHEET SP-6) 00 8" SCREENED TOPSOIL T ® O .. DENSE VEGETATION TO REMAIN T PROPOSED TREE PROTECTION FENCE PROP. GRASS �. . ��, 8T.22 S 89°48'0 W A . . . , / AREA (TYP.) _ � � � �� � PROPOSED GRASS AREA IN R.O.W. S 87,`1 4'S0„ W �' ��� � � � �, 197.1 4' 12" MIN. / SITE ADDRESS: EVERGREEN TREE DETAIL S moo ® REFER TO SHEET SP-7 PROPOSED CONVENIENCE STORE N.T.S. / Z a0v. . 1 _ _ _ FOR LANDSCAPE DETAILS WITH FILLING STATION J - \ / i PROP. GRASS 30' (TYP.) PROP. LANDSCAPE 7400 MAIN ROAD I AREA (TYP.) SWALE MATTITUCK, / PROP. SIGHT TOWN OF SOUTHOLD <I � / / 1 VISIBILITY LINE SUFFOLK COUNTY, NY 11952 I w / NP 0 DRIVEWAY / o (TYP.) LANDSCAPE NOTES: PLANT MATER IAL NOTES: DISTRICT: 1000 BLOCK: 07 / / a. LANDSCAPE CONTRACTOR (L.C.) SHALL BE RESPONSIBLE FOR LOCATING ALL 1. ALL NEW SHRUBS SHALL HAVE A FULL HEAD THAT COVERS THE CAN DIAMETER AND A SECTION: 122 LOTS: 1 & 3.2 UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. L.C. SHALL FAMILIARIZE HIM bOUBLE STRAND REIkFORCED RUBBER / 0 / HERSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK AGREE WITH THE MINIMUM OF 3 STEM/ BRANCHES. SCALE.' 1" = 20' HPE#' EMP021-01 LZ WIRE LWISTED HOSE - 2 PRECE5 / �S TF1;i F f_- SAME. 2. ALL SHRUBS SHALL BE PLANTED A MINIMUM OF 2 Fr. FROM THE EDGE OF CURBS, 1. L.C. SHALL REMOVE ALL DEBRIS FROM PROPOSED PLANTING BEDS, ALL SIDEWALKS, ROADS, AND PLANTING BED EDGES UNLESS NOTED AS DIFFERENT ON PLANTING I ROAD REMAINING VOIDS SHALL BE FILLED WITH CONTROLLED CLEAN FILL; THE 3. PLANTING SHALL NOT BE DONE IN SOIL THAT IS EXCESSIVELY MOIST OR OTHERWISE IN AD� 10/9/23 DWG # EMP021-01-SP.3a 0 LD MAIN FINAL 8 INCHES SHALL BE SCREENED TOPSOIL. CONDITION NOT SATISFACTORY FOR PLANTING IN ACCORDANCE WITH ACCEPTED HORTICULTURAL DRAWN BY.' LID CHECKED BY.' CT 2. L.C. IS RESPONSIBLE FOR ANY DAMAGE TO THE SITE OR ADJACENT s' LDMc cmrAlt STAKE 1 �I�1) PROPERTIES CAUSED BY WORK OPERATIONS AND SHALL MAKE AND REPAIRS PRACTICE. 4. ALL PLANT MATERIAL SHALL BE TRUE TO TYPE AND SPECIES SHOWN ON PROJECT PLAINS AND TITLE.' CALIPER @ 4. MULCH 2�" c° 7" MINIMUM -` OWNERS OR . AT NO COST TO THE OWNER OR ADJACENT PROPERTY AT LEAST ONE PLANT IN EACH GROUP OF PLANTS OF THE SAME SPECIES DELIVERED TO THE - -> ABOVE GROUND 3. THE L.C. SHALL BE RESPONSIBLE FOR WATERING ALL PLANT MATERIAL PRIOR PROJECT SITE SHALL BE TAGGED WITH A WEATHERPROOF LABEL STATING BOTH BOTANICAL AND TOP OF ROOT BALL TO BE 1.5' TO THE INSTALLATION OF AN IRRIGATION SYSTEM. COMMON NAME OF THE PLANT. 6" SAUCER ABOVE SURROUNDING GRADE 2. ern, 5. NO SUBSTITUTION OF SPECIES AND OR SIZES OF SPECIFIED PLANTS SHALL BE MADE UNLESS 4. AN IRRIGATION SYSTEM SHALL BE OPERATIONAL PRIOR TO LAWN / 2" LAYER OF SHREDDED ?t l ( °j�Y �_; INSTALLATION. EVIDENCE IS SUBMITTED TO THE LANDSCAPE DESIGNER IN WRITING SHOWING THAT THE PLANTS T� T 6" TOPSOIL 2" SHREDDED BARK MULCH BARK MULCH 5. ALL NEW PLANT MATERIAL SHALL BE GUARANTEED BY THE L.C. FOR A IN THE SPECIES, QUANTITY, AND/ OR SIZES SPECIFIED ARE NOT AVAILABLE T /1 �j ® p /, p �j PLAN I\T ..•,,� ., •,. . .. ,. - JLJl•11 V le t�l JLJ iJC11 �J " - :' z > PERIOD OF ONE YEAR AFTER ACCEPTANCE BY THE OWNER. L.C. SHALL 6. SUBSTITUTION OF A LARGER SIZE OF THE SAME SPECIES MAY BE MADE BY THE L.0 WITHOUT d = 3" HIGH WATER RETENTION SAUCER . 8' SCREENED TOPSOIL _ REPLACE ANY PLANT MATERIAL 50% OR MORE DEAD AFTER ONE YEAR AT NO WRITTEN APPROVAL. HOWEVER, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY ADDITIONAL .0 a � o ADD PEAT MOSS COST TO THE OWNER. COST OF THE PLANTS OR ADDITIONAL PLANTING COSTS. 8" SCREENED TOPSOIL AS PER MANUFACT. [= 6. L.C. SHALL COLLECT AND DISPOSE OF ALL DEBRIS GENERATED THROUGH 7. TREE STAKES SHALL BE DRIVEN 24" INCHES MINIMUM INTO FIRM UNDISTURBED EARTH; DO _ SPECS _ _ _ _ = . THE COURSE OF NORMAL WORK AT THE END OF EACH WORK DAY; SITE NOT DRIVE STAKES THROUGH ANY PART OF THE ROOT BALL. LOOSEN SUBSOIL 6"-10" MIN.; =III-III=III=III_I I=-�- ___ UNDISTURBED EARTH ( IN F1,J11T ) SHALL BE MAINTAINED AND KEPT FREE OF ANY POTENTIAL HAZARDS TO THE 8. ALL TRANSPLANTS THAT CANNOT BE RE-PLANTED IMMEDIATELY SHALL HAVE ITS ROOT BALL w BACKFILL W/ TOPSOIL & PEAT OWNER AND GENERAL PUBLIC. BALLED, BURLAPED, AND PROTECTED WITH MOIST MULCH. LOOSEN Brntit�►r MOSS; 3:1 RATIO BY VOLUME GROUNDCOVER 1 inchl 0 fL. ' ° 7. LANDSCAPE DESIGNER IS NOT RESPONSIBLE FOR PLANT MATERIAL LONGEVITY. 9. ALL PLANT MATERIAL SHALL BE HEALTHY, FREE FROM PESTS AND DISEASE, AND BE NURSERY 2'-6" s AROUND TRU" WATER UNTIL SETTLED 8. TEASE ROOT BALLS OF CONTAINER GROWN PLANT MATERIAL IMMEDIATELY GROWN. THE LANDSCAPE DESIGNER RETAINS THE RIGHT TO REJECT ANY UNSUITABLE PLIANT SHEET N0: IM MIN. BALL LR PLANTING DETAIL TaPSOiI (2!Si 11AHUtt<Pry PRIOR TO PLANTING. MATERIAL AND SHALL BE REPLACED BY THE L.C. AT NO EXTRA COST TO THE OWNER. Ir REMOVE ROPING AND LOOSEN N.T.S. 9. USE OF THE ROOT ZONE SURROUNDING EXISTING TREES TO REMAIN IS 10. ALL PLANTING BEDS TO BE MULCHED W/ 2" SHREDDED BARK. BURLAP KNOT AT SHRUB BASE PROHIBITED AND SHALL BE FENCED OFF FOR THE DURATION OF THE 11. ALL PLANTING BEDS TO RECEIVE 6" OF SCREENED TOP SOIL PRIOR TO PLANT INSTALLATION. p B"MIN. PROJECT. TOWN OF SOUTHOLD 10. EXISTING TOPSOIL ON SUBJECT PROPERTY SHALL NOT BE REMOVED & SHALL STREET TREE DETAIL SHRUB PLANTING DETAIL BE REUSED/ RECLAIMED ON-SITE W/ IN PROPOSED LANDSCAPE AND GRASS (FOR USE ON-SITE) N.T.S. AREAS. N.T.S. REV. 3 OF 10 10' IMIN. PLYWOOD 48"x24" 8 O.C. SILT FENCE/ FILTER FABRIC ( ) PAINTED WHfTE I l�Tr.! I WOOD OR METAL 3 I I I I I I STAKE MP.) CONCRET BLACK LETTERS FENCE POST 1 7CONS?RUCT SILT HIGH .Ir En FENCE AROUND B - - 8 WASHOUT 0.5" LAG PERIMETER OF SCREWS f f 1 ON 3 (MAX. STOCKPILE o - - DIRECTION OF SLOPE TYP.) v WOOD POST SURFACE RUNOFF PLAN NOIES: - - Q 3"x3"x8' WOOD OR METAL FENCE POSTS n POINT 1. TEMPORARY CONCRETE WASHOUT FACILITIES 10' SHOULD BE LOCATED A MINIMUM OF °i0 FT. - - \/ \%\ \/\ \/\/\/ APPROVED FILTER FABRIC MEETING SPACED 8'-0" O.C. (METAL FENCE n g O FROM STORM DRAIN INLETS. LOCATION TO _ _ ��' �� �� �� �� N.Y.S. SPECIFICATIONS (3'-0- WIDE) POSTS OR APPROVED EQUAL TO BE MIN. CJ7 ry ENGINEERING BE IDENTIFIED BY CONTRACTOR. N1 INSTALLED IN ASPHALT PAVEMENT) o ° 2. ONCE CONCRETE WASTE IS WASHED INTO I I I I I TEMPORARY SOIL STOCKPILE DETAILS ° s/ ti� THE DESIGNATED AREA AND ALLOWED 'TO 10 MIL PLASTIC __AREA OF FLOW-> BROKEHARDENN UP, REMOVED,EANDOULD BEDISP DISPOSED, OF LINING CONCRETE WASHOUT DISTURBANCE �'- '� o N.T.S. y 'J O•s�/ ,y 1860 WALT WHTI'MAN ROAD OFF-SITE. CONTRACTOR TO DISPOSE OF B"� SIGN DETAIL 2"-3• CLEAN STONE N / :` ,� rx SUITE 600 HARDENED CONCRETE ON A REGULAR BASIS. 3. THE CONCRETE WASHOUT SIGN SHALL BE w O., INSTALLED WITHIN 30FT.CONCRETE WASHOUT FACILITY. E TEMPORARY PLAN (OR EQUIVALENT) �' ( ) MELVILLE,NY 11j 47 MIN / F �o tih 516 777-4320 FAX: 516 777-4321 4. PLASTIC LINING MATERIAL SHOULD BE A STAPLES 10 MIL PLASTIC DIG. 6" WIDE AND 6" DEEP TRENCH,-� 6" �j EXISTING STORM MINIMUM OF 10 MIL POLYETHYLENE (2 PER BALE) LINING BURY BOTTOM 1'-0" OF FILTER iv UNDISTURBED O O O O ALL PHASES OF ENGINEERING DESIGN, GRATE �� O O CLOSURE SHEETING AND SHOULD BE FREE OF HOLES, BINDING WIRE 2" FABRIC, TAMP IN PLACE GROUND SEWER VELCRO TEARS, OR OTHER DEFECTS THAT SURVEYING CODE CONSULTING COMPROMISE THE IMPERMEABILITY OF THE SECTION , , MATERIAL NATIVE MATERIAL STEW BALE r 5. WASHOUT FACILITIES MUST BE CLEANED, OR 1. PLACE SILT FENCE AT LOCATIONS AS SHOWN. ZONING ANALYSIS&BID SPECIFICATION NEW FACILITIES MUST BE CONSTRUCTED ((OPTIONAL) 1/8- DIA. e� 2. THE SLOPE OF THE LAND FOR AT LEAST 30 FEET ADJACENT TO ANY SILT FENCE SHALL NOT WOOD OR METAL STEEL WIRE EXCEED 5%. AND READY FOR USE ONCE THE WASHOUT STAKES (2 PER BALE) 3. SILT FENCE SHALL BE INSTALLED SO WATER CANNOT BYPASS THE FENCE AROUND THE SIDES. LIFT STRAPS00/0 IS 75% FULL. 4. INSPECTION SHALL BE FREQUENT AND REPAIR OR REPLACEMENT SHALL BE MADE PROMPTLY. USED FOR EASY D WWW.HPEng.com 3C� 5. SILT FENCE SHALL REMAIN IN PLACE FOR THE DURATION OF THE PROJECT UNLESS OTHERWISE MOVEMENT AND t> '`s: / - /0 SECTPON B-B STAPLE DETAIL DIRECTED BY THE AGENCY HAVING JURISDICTION INSPECTION OF 6 SECTIONS OF FOLDED. FABRIC ADJOIN EACH OTHER THEY SHALL BE OVERLAPPED BY UNIT K Yi � x{ CHRIS M. TAR TA GLIA WASTE CONCRETE MANAGEMENT AREA DETAILS SILT FENCE DETAILS ! C NEvv N.T.S. N.T.S. STORM �O (ITEM 209.02000010 SEWER DANDY BAG / PROP. SILT GRATE o FENCE (TYP.) 2"X4" WOOD FRAME EXISTING _ - 50' MIN. PAVEMENT / OR .1 4Y 3' I=1 I • I. 11= / \9 €.�'c / 1�C I di r i;' (� III : ' �• •,� . • III=III ) •� / �/ r .ac. at � �' � � J - STAKE NOTES: - - Z -I I '.• `, I i lI / / ya c� �_ r� y w FABRIC 1. STONE SIZE-USE 2°-3" CLEAN STONE OR EXISTING m FILTER MOUNTABLE BERM •' O PROP. SILT PROTECTION AT / +`q+ 0• �� z - -� RECLAIMED OR RECYCLED CONCRETE EQUIVALENT. GROUND CLOTH (OPTIONAL) INLET (ITEM 141 B) (SEE DETAIL Gj�' �a / OT820� --� 2. LENGTH- NOT LESS THAN 50 FEET to PROFILE ON SHET SP-6) t� Z 3. THICKNESS-NOT LESS THAN (8) INCHES 10, N 4. WIDTH-TWELVE (12) FOOT MIN. BUT NOT LESS i / / ��� PR NGINEER DANDY BAG / '� NEW YORK LICENSE No. 078209 L o THAN THE FULL WIDTH C POINT WHERE / / wrrp�ill= I=-IIII a INGRESS OR EGRESS OCCURS. TWENTY-FOUR vo 5. FI TEROOT IF SINGLE ENTRANCE TO CLOTH-WILL BE PLACED OVER SILT. INLET ENTIRE - -- INLET PROTECTION DETAIL I " :• ® / LAWRENCE D. O'BRIEN DROP INLET BWRIED FABRIC I ? N.T.S. O AREA PRIOR TO PLACING STONE. WITH GATE 6. SURFACE WATER- ALL SURFACE WATER FLOWING EXISTING EXISTING GROUND -� -� PAVEMENT FRAME: OR pIVERTED TOWARD CONSTRUCTION I_I I N ENTRANCE SHALL BE PIPED ACROSS THE ENTRANCE. IF PIPING IS IMPRACTICAL A �--- MOUNTABLE BERM WITH 5:1 SLOPES WILL BE °o°o / "` ` PROP. SILT z PERMITTED. o ` ���\�O� ° oo° r I I I I I 7 MAINTAINED IN CONDITIONSAWHICHHW WILL PLAN VIEW �, �� 19 N / /'» (TYP.) .� FENCE TYP. GATHER EXCESS y• O� / '� I AT CORNERS I I I I( TRACKING OR FLOWING OF SEDIMENT ONTO PUBLIC RIGHT-OF-WAYS. ALL SEDIMENT SPILLED, RIGHDROPT -WASTEYS OR BEACKED RS REMOVED PUBLIC �� IMMEDIATELY. PROJG MGb FF�O 1. FILTER FABRIC SHALL HAVE AN EOS OF 40-85. BURLAP WAY 8. WHEN WASHING IS REQUIRED IT SHALL BE DONE o° BE USED FOR SHORT TERM APPLICATIONS. ON AN AREA STABILIZED WITH STONE AND O� / ' ? oo / aQ^ J J G>� cj°L� PROFESSIONAL ENGINEER 2. CUT FABRIC FROM A CONTINUOUS ROLL TO ELIMINATE JOINTS. IF 0 O O NEW YORK LICENSE No. 082537 WHICH DRAINS INTO AN APPROVED SEDIMENT JOINTS ARE NEEDED THEY WILL BE OVERLAPPED TO THE NEXT STAKE. 8" MINIMUM O �G TRAPPING DEVICE. F � o°o°° 3. STAKE MATERIALS WILL BE STANDARD 2" x 4" WOOD OR IEQUIVALENT. 9. PERIODIC INSPECTION AND NEEDED MAINTENANCE 2"-3" CLEAN STONE ��P� o00 '���� UNLESS NLJUR SSCAPPROVED THESE B ALL AGENCIES TO BEUTILIZED METAL WITH A MINIMUM LENGTH OF, 3 FEET. SHALL BE PROVIDED AFTER EACH RAIN EVENT. t,� .'' ARE 4. SPACE STAKES EVENLY AROUND INLET 3 FEET APART AND DRIVE A 10. CONTRACTOR TO ENSURE THAT THE TRACKING GEOTEXTILE UNDERLINER ��� d"} f ! •, FOR CONSTRUCTION. OWNER/ CONTRACTOR ARE MINIMUM 18 INCHES DEEP. SPANS GREATER THAN 3 FEET MAY BE BRIDGED PREVENTION REMAINS EFFECTIVE DURING ALL ti / . ° RESPONSIBLE FOR CONFIRMING ALL REQUIRED AGENCY WITH THE USE OF WIRE MESH BEHIND THE FILTER FABRIC FOR SUPPORT. CONSTRUCTION PHASES. CONTRACTOR TO TRACK / ¢ ® ® - APPROVALS HAVE BEEN SECURED PRIOR TO 5. FABRIC SHALL BE EMBEDDED 1 FOOT MINIMUM BELOW GROUND AND PADS AS NECESSARY. ISOMETRIC VIEW o / a� ® © �i COMMENCEMENT OF WORK, WHETHER DESCRIBED ON BACKFILLED. IT SHALL BE SECURELY FASTENED TO THE STAKES AND FRAME. , �p THESE PLANS OR OTHERWISE. 6. A 2" x 4" WOOD FRAME SHALL BE COMPLETED AROUND ITHE CREST / O ~� ® \ \ ; _`, N REVISIONS OF THE FABRIC FOR OVER FLOW STABILITY. CONSTRUCTION ENTRANCE DETAILS / , Q FILTER FABRIC DRIP REV N0. DATE REVISION N.T.S. ' ®•/ ^ `J " INLET PROTECTION DETAIL o ?'= 21 _,� 1 1012412J MISC. REVS N.T.S. • ° 2 5123124 PER TOWN COMMENTS 3 712JI26 REV SITE LAYOUT PROP. DANDY CURB BAG .ate •.. ,; � o (TYP.) PROP. 2 STORY O BUILDING �a N D F / 4,906 SF G.F.A. J ,+ �O- _ _ •'.. - ( �. . _ ' STANLEY J. FLISS JR. & JANICE M. FLISS _ .J ZONE: GENERAL BUSINESS B �, USE: RESIDENCE -1st FLOOR 2,800 SF CONVENIENCE STORE/ RETAIL AREA: 1,231 SF J O 01 ` 0 O \� -2nd FLOOR 2,106 SF ' OFFICE AREA: 1,868 SF J Ln i ' 0 21 STAIRWELL AREA: 238 SF ' �O ® (NO BASEM 21 ENT) J 'd J \ THE EDUCATION LAW OF THE STATE OF NEW YORK PROHIBITS ANY �t PERSON ALTERING ANYTHING ON THESE DRAWINGS AND/OR THE �- J / Q �� ��d ACCOMPANYING SPECIFICATIONS, UNLESS IT IS UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. WHERE SUCH kov ALTERATIONS ARE MADE, THE PROFESSIONAL ENGINEER MUST SIGN PROP. CONSTRUCTION O PROP. CONSTRUCTION "a AND SEAL, DATE AND DESCRIBE THE FULL EXTENT OF THE PROP. CONC. ENTRANCE OFFICE TRAILER O ` ?s SYMBOL LEGEND ALTERATION ON THE DRAWING AND/OR IN THE SPECIFICATIONS. / (NY5 EDUCATION LAW SECTION 7209-2) WASHOUT O O MATERIAL EQUIPMENT F ALL ITEMS ARE EXIS77NG TO REMAIN UNLESS OTHERWISE NOTED titi •' \ �� / STAGING AREA PROP. SOIL / YS MBOL DESCRIPTION STOCKPILE AREA Q o O W/ SILT FENCE w - w CURB INLET / I I PROP. _ o SOLID MANHOLE COVER 15 22 ° PORTABLE H� 0 zs o N o 22 . 16 0° SANITARY INLET GRATE NOV 17 °°o B2 aj. FACILITY `� `� 6 2026 PROPOSED INLET PROTECTION N PLANNING BOARD 18 19 0 \ ' o I I( SOUTIiOLD 7G�41N / 2 PROP. SILT . °o- 21 N PROPOSED SILT PROTECTION --�-� 12 FENCE (TYP.) • H ®� O � a� (SEE DETAIL ON SHEET SP-6) 22 - - i----- .� •y�tik, � '�� �s E ,(lr. � - �-�"- PROPOSED SILT FENCE ,Yel t v '� ..•1 a VI'�'{: ' s �. � ° 2 ' ,S 89°48 0 W.`A0 E.` I 1� I .`1 g�;a`4'.` 25 PROPOSED CONSTRUCTION ENTRANCE ..S. °1 q' 23 SITE ADDRESS _. -= =, 24 .'. -'-�' D 2 .2 3 a PROPOSED GRASS AREA IN R.O.W. PROPOSED CONVENIENCE :O. E IENCE STORE B a6 ` . .- ?3 WITH FILLING STATION 7400 MAIN ROAD D MATTITUCK, .IN TOWN OF SOUTHOLD ` SUFFOLK COUNTY NY 11952 DISTRICT: 1000 BLOCK: 07 SECTION: 122 LOTS: 1 & 3.2 /• -` 7RAFIFIC FLGW SCALE. 1" = 20' HPE EMP021-01 ROAD � 10/9/23 DWG EMP021-01-SP.3a .. . :... •` OLD MAIN LD CHECKED BY. CT ice,% '•' (TOWN JURISDICTION) TRAFFIC FLOW � GRAPHIC SCALE EROSION 20 0 10 20 Lj 4-� CONTROL PLAN ( I:N FEET ) 1 inch = 20 ft. SHEET N0: D 0 0 REV. 3 OF 10 LIGHT FIXTURE HIGH M ,Q POINT ' . 0 0. 0 0. 0 �t0. 0 0 . 0 0. 0 0. 0 0. 0 0. 0 0. 0 0 I 0 . 0 . 0 . 0 0 /t(d 0 +0 . 0 +0. 0 0. 0 '0. 0 �� ENGINEERING MOUNTING ARM ter. + + + + + + + + + + + + I + + + + + + + + + + 0 . 0 0 . 0 0 . 0 0. 0 0. 0. 0 0. 0 0. 0 0. 0 . 0 . 0 0. 0 0. 0 0 . 0 0. 0 0. 0 0. 0 0. 0 0 . 0 0. 0 1860 WALT WHITMAN ROAD z 0 SUITE 600 o + + + + + + + + + + + + + + + + + + + + + 0. 0 0. 0 0. 0 0. 0 0. 0 0. 0 0. 0 0 0 0 . 0 . 0 0 . 0 0. 0 . 0 . 0 0 . 0 0. 0 0. 0 0. 0 0. 0 ArldX,�0 0. 0 0. 0 MELVILLE,NY 11747 o POLE • ° s COPAM REALTY COMPANY _ s (516)777-4320 FAX: (516)777-4321 �6 S� ZONE: GENERAL BUSINESS (B) + + + + + + + + + + + + I + + + + USE+ c ONALD90 RE TAURA + ALL PHASES OF ENGINEERING DESIGN o. o O. o o. o O. o O . o o.o O. o 0. 0 0. 0 0. s 0. 0 0. 0 0 . 0 0 . 0.0 0. 0 . o 1.0 o. 0. 0 �,��� o. o o . o cM.� o. � �d. o o . o , SURVEYING,CODE WALL MOUNTED LED LIGHT FIXTURE 7o,� ZONING ANALYS S&BID O SPECIFICATION + + + + + + + + + + + + + + + + t + t + + + F �+ + + t + t N.T.S. I O . o O. 0 0. 0 0. o 0. 0 0. 0 0 . 0 0. 0 0. 0 0. 0. 0 0. 0 0. 0 0. 0. 0 . 0 0. 0 0. 0 0. 0 0. 9 0. 0 0. 0 0. 0 0. 0 0.0 0. 0 LITHONIA LIGHTING MODEL #:WSQ_LED_1_10A700_30K_SR2_MVOL f, �� www.HPEng.com HOE WITH ND (MOUNTED AT 10'H) + + + + + + + + + + + + + + + + + + + + + + + CHRIS M. TARTAGLIA COVER CONDUIT STUB-UP 0 . 0 0. 0 0. 0 0. 0 0. 0 0. 0 0. 0 0. 0 . 0 0 . O 0. O 0. 0 . 0 0 . 0 0. O O. p O. O O. O O. O O O. O O. O O. O O. O O. O FACE OF FIXTURE TO BE GROUT / rt� 11 ALIGNED WITH BACK OF CURB WHERE POSSIBLE Y GRADE 0. O 0. 0 0. O 0. 0 0. 0 0. 0 0. 0 0 . 0 . 0 0 . 0 . 0 0 . 0 0. 0 0. 0 0 0.0 0.0 0,.-6 . 0 0. 0 0. 0 0. 0 0. 0 0 . 0 0 . 0 0. 0 0. 0 0. 0 / wj q p � CONCRETE CURB /\ LU TYPICAL POLE FOUNDATION + + + + + + + + + + + + + + + + + + + + + + + + + + + ;4 "• I '�- -. 2- 4,000 PSI CONCRETE 0. 0 0. 0 0. O 0. 0. 0 0. 0. 0 0. 0 0 0. O O 0 . 0 . 0 '/0.0 0. 0 z0. 0. 0 0. O 0. 0 0. 0 . 0 0. 0 0. 0 0. 0 0. 0 0. 0. 0 �+ - \� oI o `Q / Q , �o (8) 02 TIES O 12" O.C. S a7824 ti 0. 0 0. 0 0. 0 0. 0 . 0 0. 0. 0 . 0 0 . 1 0. 1 . l 0. 0 0� 0. 0 0 . 0 0. 0 0. 0 0. 0 0. 0 0. 0 0. 0 0. . 0 0. 0 0 . 0 •P ., - o '' ,+ � j`�•`� NEW YORK LICENSE No. 078209 (8) #6 VERTICAL ONE 1"0 x 36" LONG GALVANIZED AT EACH CORNER CANOPY LED LIGHT FIXTURE ���' +/^ + + � � + + + + + + + + + + + + LAWRENCE D. O'BRIEN ANCHOR W/ 4" HOOK 2'-s m° 0. 0 +0. 0 0. +0. 0 0 .0 t . 0 +0. 0 0. 0 0. 0 . 0. /'0. 1 0. 1 0 1 . 0 0. O 0. 0 0 . 0 0. 0 0. 0 0 0. 0 0 . 0 0. 0 . 0 0 . 0 0. 0 0. 0 N.T.S. LSI MODEL #:GRUB-SC-SS-30 AREA LIGHT DETAIL (MOUNTED AT 15 H) + i N.T.S. t t t t t + t + / t t + z t t t t t t t t t + t t t 0. 0 0. 0 . 0 0. 0 0. � 0 0 . 0 . 1 0 . 1 410. 0.7 0.5 -,A. 0®1 0. 0 0. 0 0. 0 0. 0 0 . 0 . 0 0. 0 0 . 0 0 0 . 0 0 . 0 0. 0 0 . 0 0. 0 O 0. 0 0. 0 0. 0 0.0 0 . 0 0 . 0 0. 0 0. 0 0. 0 0. 0 . 0 0. 0 . �51 0. 0 0. 1 0. 1 0 . 6 . 9 �. 9 +2.9 ®0. 4 0. 1 0 . 0 0. 0 0. 0. 0. 0 0 . 0 0 . 0 . 0 0. 0 0. 0 0 . 0 0. 0 + + + + + + + + + + �J+ + + + + + + + + + + + + + + + + + + + + + + PROFESSIONAL ENGINEER 0. 0 0. 0 0. 0 0. 0 0 . 0 0.0 0. 0 0. 0 0. 0 0 . 0 . 0 .�$�� 0. 0 . 1 0. 4 1 . 8 3. 8 4 . E® 2 . 1 0. 9 0. 3 0 . 0. 0 0. 0 0. 0 0. 0 . 0. 0 0. 0 0 . 0 0. 0 0. 0 0. 0 0. 0 O Ic> � NEW YORK LICENSE No. 082537 PROP. SINGLE FIXTURE LED P o O� AREA LIGHT W/ SHIELD ® 14'H `� ���` UNLESS APPROVED BY ALL AGENCIES HAVING JURISDICTION, THESE PLANS ARE NOT TO BE UTILIZED + + + + + + + + + + G + + + + + + + + + + + + + + + + '0. + + + + + + + FOR CONSTRUCTION. OWNER/ CONTRACTOR ARE = s. 0. 0 0. 0 0. 0 0. 0 0 . 0 0. 0 0. 0 0. 0.0 0. PF�\ 0 0. 0 . l 0. . 3 . 5 1. 0 . 0 2 .5 2 . 6 2 . 6 2 . 1 0. 0. 1 . 0 0. 0 0. 0 0) 0. 0 0.0 0. 0 0. 0 0. 0 0. 0 0. 0 0. 0 °rL RESPONSIBLE FOR CONFIRMING ALL REQUIRED AGENCY Oa01 �� 5� APPROVALS HAVE BEEN SECURED PRIOR TO S S COMMENCEMENT OF WORK, WHETHER DESCRIBED ON o da THESE PLANS OR OTHERWISE. + + + + + + + + + + PFF + + + + + + '� -a + + + + + + + + + + + + + 0.0 0. 0 0.0 0. 0 0. 0 0. 0 . 0 0. 0 . 0 . 0 . 0 0. 1 . 1 0. 2 . 1 2 . 1 . 8 2 . 4 2 .2 2 . 5 �d` 4 . 7 0. 1 0. 0 0. 0 . 0 0.0 0. 0 0 . 0 0. 0 0 . 0 0. 0 0. 0 0. 0 0. 0 0. 0 REVISIONS s (D 0 REV NO. DATE REVISION + + + + + + + + + + + + + + + + + +p + + + + + + + + + 1 1012412J MISC. REVS ir. 0. 0 0 . 0 0. 0 0 . 0 .0 0. 0. 0 . 0 0. 0 0. 0 0 . 0. 1 0 . 0 . 4 1 . 3 4 . 8 6.0 3 . 1C) 3. 1 1 . 8 1. 8 3 . 1 6 . 6 0 .2 0. 1 0 . 0 0. 0 . 0 0. 0 0. 0 0. 0 1/1 PROP.. SINGLE FIXTURE LED ��� 2 512JI24 PER TOWN COMMEMS V AREA LIGHT W/ SHIELD 0 14'H © a N + + + + + + + + + + + + + + + + + + + + + CO 3 712JI26 REV SITE LAYOUT LED AREA, LIGHT FIXTURE 0. 0 o . o o. o o. o . o 0. 0 0 0.0 . 1 0 . 1 .2 0. 4 0. 6 1 . 4. 1 4 .0 3 . 9 2. 3 1.7 3.2 � '. - �, . 9 V o: s° 0 . 1 0. 0 +(� 0. 0 0. 0 0 . 0 0. 0 ;� > N.T.S. LSI MODEL #:SLM-LED•-09L-SIL-2-30-70CR1-IL (SHIELD) + + + + + +,: + + + + + + + 0. 0 0. 0 . 0 . 0 0 . 0. 0 . 0 0 . 1 0. 1 0 1 0.3 "1?: 1. 1 2 . 4 3 .3 3.7 2 . 4. 8' a 2 . 3 0. 3 0 . 0 0. 0. 0 0. 0 0. 0 0. 0 ;y < \\ r' 0 + ° + + + + + + + + + + + + + + PROP. 2 STORY 0. 0 0 0. 0 . 0 0. 0 0 . 0 0. 0. 1 0. 1 0 ,. 0. 4 3.4 3 .4 2 . 8 3 .20 0 3 .4 3 . 4 2. 4 .2 3.�5 . 991 BUILDING ^�' ;t 0 . 6 0. 1 0 . 0. 0 0. O N/�/ t0. 0 PROP. SINGLE FIXTURE LED (4,906 SF G.F.A.) \ STANLEY J. FLISS JR. AREA LIGHT W/ SHIELD 0 1 I / ��� `t �/ a ° & JANICE M. FLISS + + + + + + + + + + + + + + + + + + + + + 0. 0 0. 0 0 0. 0 . 1 0 . 1 0.2 5 5. 6 6. 4 . 8 6.7 9.5 4 .5 2 . 1 .4 3 el� 0. 8 0.3 0. 0N�3 GENERL �USINE (� .+ \ r USE: RESIDENCE r .• / •� . �'�� � -1st FLOOR 2,800 S� � CONVENIENCE STORE v 0. 0. 0 + . 0 0. 0 0. 1 t . 1 0. . 8 +5 . 4 6.5 6. 0 9.2 5. 9 ® 4 G6. 6 4 .4 1 . 4 + , g 3 . / RETAIL AREA: 1,10 SF d -2nI FLOOR 2,106 SF J . 9 0. 9 0 0 . 1 0. 0 0 . 0 0. 0 \ 0 OFFICE AREA: 1,868 SF 6' ® STAIRWELL AREA: 238 SF ° ; (NO BASEMENT" HOUSE SIDE SHIELD DETAIL �� \ O + �° THE EDUCATION LAW OF THE STATE OF NEW YORK PROHIBITS ANY 0. 0 0. 0 0 . 0. 0 0. a 3.2 6 16. 4 4 . 5 4 . 6 6. 4 2 7 . 8 3 5.7 0 . 6 6.7 2 .2 .2 1 . % . 4 6. 4 2 .3 0 . 4 0 0. O 0. 0 0.0 0. 0 PERSON ALTERING ANYTHING ON THESE DRAWINGS AND/OR THE N.T.S. �' \ ® ACCOMPANYING SPECIFICATIONS, UNLESS IT IS UNDER THE PROP. SINGLE FIXTURE LED o°°�� „` DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. WHERE SUCH {} � AREA LIGHT W/ SHIELD 0 14'H 0 ' fi''{ ALTERATIONS ARE MADE, THE PROFESSIONAL ENGINEER MUST SIGN AND SEAL, DATE AND DESCRIBE THE FULL EXTENT OF THE '0. 0 + + + + + + \+ + + + + + + + + + + �\ , O 6. O 2 . O O .5 O. 1 + O. O O. O O. O O. O ALTERATION ON THE DRAWING AND/OR IN THE SPECIFICATIONS. 0. 0 . 0 0 . 0 . 1 0.3 1 . 4 5. 1 . 9 5. 5 4 . 5 4 . 4 11. 0. 1 3 3.4 31. 8 ®3 0 .7 12 .1 3 . 4 1 .5 8 (NYS EDUCATION LAW SECTION 7209-2) \ PROP. CANOPY LED LIGHT O \ PROP. WALL MOUNTED LED LIGHT "^ \ FIXTURE (TYP. of 10) ® ° 0 FIXTURE (TYP. OF 8) e + + + + + + + + + + + + + + +� + + � + + + + + + + + + + , t 0 . 0 . 0 0. ,0 0. 1 0.4 1 . 8 04 . 5.5 6. 4 .2 3.5 6.3 18 34 1 027 . 3 26� .:2 4 .2 1. 8 2 . 0 4 . 4 2 . 00 0 .0 0. 0 0. 0 \ 0 0� ;•" ( 0. 0.0 0.0 0. 1 0. 3 1 . 9 3. 9 . 6 4 . 8 4 . 0 2 . 8 3. 6 8 .3 . 4 05.5 4 . 4 8 .3 3. 5 2 . 3 2 .7 4 . 2 5 . . 9 .2 0 .5 0 .2 0 . 1 �.�0 0. 0 0 .0 0. 0 Q��I [�\�I D�� PROP. SINGLE FIXTURE LED w n O CODE SECTION: PERMITTED: PROVIDED: P�uV 6 Z�Z6 \ e AREA LIGHT W/ SHIELD A 14'H o U Y . 0 '0 .0 0.0 0. 0 0 . 1 o.2 1 .2 3 .5 5. 5. 1 .3 3 . 6 2 . 9 3 . 8 t7 .7 10 . ° ° 3 .4 4. 1 5. 3 5. ° . 3 9 l. 6 0. 4 0. 1 0. 1 ^� 0. 0 0. 0 0. 0 § 280-117(A) ALL OUTDOOR LIGHTING SHALL BE COMPLIES SOUTHGLD'f01�;11 (V o SHIELDED So THAT THE LIGHT SOURCE IS PLANNING fi0AR0 � PROP. SINGLE FIXTURE LED O a - NOT VISIBLE FROM ADJACENT PROPERTIES AREA LIGHT W/ SHIELD A 14'H AND ROADWAYS. LIGHTING FIXTURES SHALL + + + + '0 + + + + + + + + + + + + + + + + '0 °+ + + + FOCUS AND DIRECT THE LIGHT IN SUCH A SIDE SHIELD DETAIL � ;; . 0 0 . 0 0.0 0. 0 0. 1 0.2 0 .7 1 . 6 3 .4 5. 6 6.51 . 1 5.5 4 . 1 2 .7 2 .7 3 .2 4 . 4 4 .3 3 . °. 1 . 8 0 . 6 0.2 0. 1 0. 0 r� 0. 0 0. 0 0. 0 MANNER AS TO CONTAIN THE LIGHT AND N.T.S. -0 ,. ,„a' PROP. SINGLE FIXTURE LED \ N GLARE WITHIN PROPERTY BOUNDARIES. N AREA LIGHT W/ SHIELD ® 14'H § 280-117(B) IT IS A GENERAL PRINCIPLE of THE TOWN COMPLIES SITE ADDRESS. + + + + + + + + + + + + Q+ + + + ° � + + + '0 + + + '0 + + + THAT PARKING LOT LIGHTS SHOULD BE 0. 0 0 . 0 0. 0 0. 0, _ 0 0. 1 0.3 0.5 a 2 .2 3 . 9 4 . 04 2.7 1. 1. 0 1 . 1. 8 4 . 6 .5 2 .4 1. 0 0.2 0. 1 0. 1 0. 0 0. 0 0. 0 0. 0 0. 0 TURNED OFF OR REDUCED IN INTENSITY \ - 10 BETWEEN 11:30 P.M. AND 4:00 A.M. PROPOSED CONVENIENCE STORE WITH FILLING STATION + +� 87+ + + S 89° „ CT. + + + + + + + + + 1 7 14' + + + + + § 280-117(C) ALL FREESTANDING OUTDOOR LIGHTING COMPLIES 0. 0 0. 0 0.0 0. 0 . 1 0. 1 OS 287 1 6t.� .2 ( � 0.2 O .2 Q. 0 .3 0. 3 0.3 0 .4 0. 8 2 . 0 2 .7 1 . 4 0. 5 0. 1 . 0 0. 0 0. 0 0. 0 0. 0 0. 0 FIXTURES SHALL BE LIMITED TO A HEIGHT OF NO MORE THAN 14 FEET ABOVE 7400 MAIN ROAD PROP. SINGLE FIXTURE LED GROUND LEVEL. THE FIXTURE SHALL MATTITUCK, AIREA LIGHT W/ SHIELD 0 14'H FOCUS AND DIRECT THE LIGHT AS 6' + ® + + + + + + + + + + + O + + + + + + + + + + + + + SPECIFIED IN SUBSECTION A ABOVE. TOWN OF SOUTHOLD _ .0 . o�1a . 0 0. 0 0 . 0 0. 0 0 . 0 0. 1 0 . 1 0. 1 0 . 1 0. 1 0. 1 0. 1 . 6 0. 7 0 .5 0.2 0. 1 0. 1 0 . 0 0. 0 0. 0 0. 0 0. 0 0. 0 0. 0 SUFFOLK COUNTY, NY 11952 ® LIGHTING NOTES: 1. LIGHTING SHALL BE DIRECTED AS NOT TO SHINE ONTO NEIGHBORING PROPERTIES, DISTRICT: 1000 BLOCK: 07 �l 0 . 0 0.0 0.0 0. 0. 0 0 . 0 0. 0 0. 0 0 . 0 0. 0 0 . 0 0. 0 0. 1 0. 1 0. 1 0 . 1 0. 1 0.2 0.2 0.2 0 . 1 0. 1 0. 0 0. 0 0 . 0 0. 0 0. 0 0. 0 0. 0 0. 0 0. 0 PROVIDE SHIELDS AS NECESSARY. SECTION: 122 LOTS: 1 & 3.2 2. ALL LIGHTING FIXTURES SHALL CONFORM TO TOWN OF SOUTHOLD LIGHTING REQUIREMENTS. SCALE. 1" = 20' HPE �! EMP021-01 S 3. LIGHT FIXTURES SUPPLIED BY MANUFACTURERS SHOWN OR APPROVED EQUAL. + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + AIMING ANGLE: 0 DEG. FROM NADIR QA 10 g 23 DWG EMP021-01-SP.3a 0. 0 0 . 0 0.0 0. 0 0. 0 0. 0 0 . 0 0. 0 0 . 0 0. 0 0. 0 0 . 0 0. 0 0. 0 0 . 0 0. 0 0. 0 0 . 1 0. 1 0. 1 0. 1 0. 1 0. 0 0 . 0 0. 0 0. 0 0. 0 0. 0 0. 0 0. 0 0. 0 0. 0 4. SITE LIGHTING LEVELS: / PROVIDED ® ROADWAY : 5.1* DRAWN 8Y• Lp CHECKED BY.• CT AVERAGE : 1.10 MAX: 35.7 TRAFFIC FLOW MIN. 0.00 TITLE. OLD MAIN ROAD (TOWN JURISDICTION) LIGHTING PLAN TRAF�OW GRAPHIC SCALE 20 0 10 20 SHEET 0.• ( IN FEET ) 1 inch = 20 ft. THIS PLAN TO BE UTILIZED FOR �%ZD o O LIGHTING PURPOSES ONLY REV. 3 OF 10 f PRECAST CAP 8 ✓ }d s i Fr CURB 1�N IM SPq q sc ROADWAY CONE nr / CFR .^» jr.. �. ANCHORS HIGH Q I ORS BOND BEAM W/ (2) d• 4 CONTINUOUS DAT REINFORCED O 16" O.C. POINT ' HORIZONTAL WALL a `:\ \;' /y`',"+�"..�^ 9 � gyp.,.• •\ TYPICAL WALL I \'• c ..'o $'. / o FINISH TO MATCH °° BUILDING um SANDBAG ENGINEERING / 6 o x 2 FT - MAX. ROADWAY CONE o o FT Y. PROP. CURB �I„ u o oQ m I CURB LINE 2 OF 2A x 4ENGfPRDP �C✓ ' 1.12 PER FOOT SAND BAG (TYP.) 1860 WALT WHITMAN ROAD # u J o N 5 0 24" WIRE MESH ATTACHED 2" x 4" WEIR _ GALVANIZED STEEL o n I I ATTACH WIRE MESH 70 WEIR\' d o (� w VERTIICAL GROUT 10 v� TO WEIR o CELL SOLID U-CHANNEL SIGN POST o FULL HEIGHT, SAND BAG S 6" EXISTING ROPOSED GRAT£ — CURB LINE SUITE 600 � MESH SPACER� o x 4" WEI2" x 4" SPACER MELVILLE,NY 11747 PROP. CONC. \ ` \/ , , 1 SCIMU WALL 2" x 4" SPACER (516)777-4320 FAX: (516)777-4321 WALK 1 1 `:'\ \ :`.,. FINISHED GRADE $ G£OTEXTILE MATERIAL ATTACHED TO MESH (6" x 6" MIN.) PROP. ADA PARKING SIGN = ,:9 f \PROP. (2) COATS 4" � MOUNTED TO POST % nloln I �" COMPRESSION FILLER W/ EXISTING/PROPOSED WIDE PAINTED STRIPING \ / \ - I°insEALANT (TYP. ALL SIDES) sEDs1ENT aAD ROAD ELEVATION ALL PHASES OF ENGINEERING DESIGN, PROP. TRUNCATED DOME / nl;iu O PAVEMENT/ GRADE I. SURVEYING,CODE CONSULTING, (WHITE AT STANDARD \ \ `DETECTABLE WARNING SURFACE ;�" urlll 1 W 6x6-6 6 WF REINFORCED STALLS) iv (SEE GRADING PLAN) X W/ 6x6-6/6 WWF AT MESH TOH E sTBiNc/ ZONING ANALYSIS&BID SPECIFICATION n l01 nWIRE\ (SEE DETAIL, THIS SHEET) 0 01n 121 �� ` f-_fin=' ID:% n PROPOSED GRATE ON 3 SIDES. SEDIMENT FILTER BAG a . ;•• 1 PROP. "NO PARKING ANY TIME" tir.. �e �:) `: SIGN MOUNTED TO POST SIGN POST DETAIL DOWELS TO MATCH Y GROUT CMU CELLS SOLID www.HPEng.com ^SORDAALMN�NLAP SPLICE BELOW GRADE (TYPJ SILT PROTECTION FOR SURFACE g' N.T.S. o c'rs Z 3" V-2^ POURED CONCRETE FOOTING , , 2" MINIMUM INLET WITH CURB INLET / M U COMPACTED n v (CLEAR) CHRIS M. TARTAGLIA ASPHALT CONC. NYSDOT ITEM 6F f DRAINAGE STRUCTURES �E(�, o \ TAR SEAL ° V y 2-1/2" MINIMUM COMPACTED DENSE b a J ® I J :°?,,, / / NTS �i O 6" CONC. MAT W L GRADED BASE COURSE NYSDOT TYPE 3 n .. 4 • MAR , 6x6 W4.OxW4.O WWF ITEM 141 B �� PROP. 4,000 PSI 28 DAYSZ 4" NYSDOT 4-RCA Ua Q FLUSH .'r,;;r ! ° SUBBASE IF REQUIRED 3'-0" (FOR USE IN NY D T CURB w',. � S 0 R.O.W. ' 4 5 LONG BARS AND 5 y,•'` " ~ TACK COAT o)2a" TRANS. r- Yl wog �, ' \ ° �\ �" " * INCREASE DEPTH OF FOUNDATION TO MAUNTAIN FROST . t/ DEPTH — SEE GRADING PLAN FOR ELEVMTIONS PROP. ADA PARKING SIGN ° '19 MOUNTED TO BLDG. WALL o 0 0°00 0 0000 0 oo eo 9� o e ° 0 %0 e0e e ° 1 WALL SECTION . ° °s�yp0e o��,aoo a��� 00 ° °Woo ROUNDED CONCRETE 07824��,,``, AT TOP PR ` NGINEER QR o o d o0 0 �0000 6" DIA. STEEL NEW YORK LICENSE No. 078209 PROP. (2) COATS og o00 °mod o0 0 ° 4" WIDE PAINTED � STRIPING (BLUE PROP. NON-SLIP MEDIUM N ® � CONCRETE C N E•j T Ei MAT T POST FILLED BROOM FINISHED SURFACE 1 y 1 JLJ 1�J LAWRENCE D. 0 BRIEN W/ CONCRETE/ o � AT ADA STALLS) 20'_p" PAINT YELLOW <r 4-03 (MAX. 2% CROSS SLOPE) PAVEMENT 7 E� F (r � 7 T DETAIL PVC SLEEVE TO N.T.S. ALLOW BOLLARD EXCEL AIR MACHINE MODEL#SC05 REMOVAL o OUTSIDE BUILDING / WIDTH VARIES O (OR APPROVED EQUIVALENT) WALL SEE SITE PLAN FOR DIMENSIONS SEE 'TOWN OF SOUTHOLD 4'-0" NOTES: JOINT FILLER TYPE A' COMMERCIAL IN. GRADE (TYP.) n . �° ° d 6" CURB DETAIL" ON SHEET ° O ,° O °° O ° ° O 1. ACCESSIBLE PARKING SIGN SHALL. CONFORM WITH CURRENT SP-7 000 O °000 °o O a O o O o O o FEDERAL, STATE AND LOCAL CODES AND REGULATIONS. 4" THICK CONC. SLOPE 1/4"/FT (MAX.) , 6" BOLLARD (TYP.) (SEE )000000oo0°DODO00 o Doo0o0°00°0°oOo( WALK 4000 PSI 0 DETAIL THIS SHEET) _—_ —_ as _ _= - 2. VAN ACCESSIBLE SIGN SHALL COMIFORM WITH CURRENT I d to 28 DAY PCC :;.' ' .; -:::: :'" o FEDERAL, STATE AND LOCAL CODES AND REGULATIONS. ITEM #105 \0° °° 'Po "rob �$e° g° .'.,." T� �T —III—III— = I III— PROFESSIONAL ENGINEER ADA STANDARD PARKING STALL �`' °°be° °D 1 ° ° 4" SAND BASE v n NEW YORK LICENSE No. 082537 •;,:i'•; v COMPACTED FILL 8'-0" 8'-0" CONCRETE FOOTING UNLESS APPROVED BY ALL AGENCIES HAVING STRIPING AND ADA RAMP DETAIL NOTE:` :r:`>- , ,'-6" DIA. PROVIDE 1/4" TOOLED JOINTS ® 5'-O" O.C. g" g 75„ r. ►1 JURISDICTION, THESE PLANS ARE NOT TO BE UTILIZED (TYP.) FOR CONSTRUCTION. OWNER/ CONTRACTOR ARE N.T.S. RESPONSIBLE FOR CONFIRMING ALL REQUIRED AGENCY BUILDING WA I��� .�° •I' � APPROVALS HAVE BEEN SECURED PRIOR TO ON � T � PIPE BOLLARD D DETAIL THESE PLANS NOR OTHERWISE. T OF WORK,In - HETHER DESCRIBED ON 1�1 � ���� CURB� ���A�11L� Ii 11 12" 12" / / ° N.T.S. REVISIONS GREEN LETTERS N.T.S. / \ / \ ° V° ° ° ° REV NO. DATE REVISION RESERVE 24" #5 REBAR \` `/ I 3 -0 ° ° ° „ 2-3/8" O.D. STAINLESS 1 10/24/23 MISC. REDS WHITE BACKGROUND NO ., STEEL TUBING 2 512JI24 PER TOWN COMMENTS PARKING FRONT ELEVATION _ —AZURE BLUE ARKING 0.. �;Y, A X e 6" CURB PLAN 3 712JI26 REV SITE LAYOUT REVEAL 3'-O" CO ® oo X GRADE ° 4/� d•• MUELLER STAINLESS STEEL 1"CONDUIT of no ANY URETHANE V-5 1/8" I RED LETTERS ' � d d d Q '< 12" BELOW B HANVDLE T N GATES INSTALL 12"H o ° TIME a d GRADE M --r--- ------ -- ----- -- - CONCRETE - _ PEDESTAL i� 1 7" CURB TERMINATION DETAIL ``\ II o FIN. GRADE VAN 'i' 1 N.T.S. - - =III—III— ACCESSIBLE 6'-0" - _.�:.. --) -11 I == I F:9 21 ,/2" �, -1: =1 _-� 1= ., 1 -III-1 I I_ - — _III—III— . : ,. GRADE 12 GRADE _ III_ .�.. •. .,, I _I _ I °' I —I RESERVED PARKING SIGN (M.U.T.C.D. #R7-1) 10 1/2' 10"0 ! 6" MOUNTED TO POST NO PARKING ANY TINIE SIGN ; , L 1 PLAN VIEW 1 MOUNTED TO POST PROVIDE 3/4" 'STAINLESS/8" X4STEEL -3/8" ANCHOR ROD PVC SLEEVES INNATIVE SOIL TYP. CONCRETE (TYP. CANE BOLT ® AIR STATION DETAIL ( ) CONCRETE FOOTING (TYP. OF 2) COLOR: I EACH GATE THE EDUCATION LAW OF THE STATE OF NEW YORK PROHIBITS ANY O OPEN & CONTRACTOR TO VERIFY UNIT MODEL W OWNER GRANULAR AREA (TYP. OF 2) PERSON ALTERING ANYTHING ON THESE DRAWINGS AND/OR THE LEGEND & BORDER GREEN (NON-REFLECTORIZED) (ALTERNATE SIDES ( / ) T COLOR: CLOSED �OF PANEL NTS ACCOMPANYING SPECIFICATIONS, UNLESS IT IS UNDER THE BACKGROUND WHITE (NON-REFLECTORIZED) LEGEND & BORDER RED (NON-REFLECTORIZED) POSITIONS) ) DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. WHERE SUCH SYMBOL WHITE (NON-REFLECTORIZED) BACCKGROUND WHITE ( NON-REFLECTORIZED) 8"Hx16"W ALTERATIONS ARE MADE, THE PROFESSIONAL ENGINEER MUST SIGN BACKGROUND BLUE (NON-RE:FLECTORIZED) ENLARGE TRASH CONTINUOUS T AND SEAL, DATE AND DESCRIBE THE FULL EXTENT OF THE ENCL. FOUNDATION ELEVATION CONC. FOOTING "U 9' BICYCLE RACK DETAIL (N THE DRAWING SECTION AND/OR;N THE SPECIFICATIONS. � W/ MONOLITHIC POUR W/(2) #5 REBARS A C C �)S�lll�L E s.I G 1� DETAILS � 0 24"x24"x24" POST (TYP.) FOOTING (TYP.) 3.-0n (ACCOMMODATES 2 BICYCLES EACH) N.T.',S. TRASH ENCLOSURE, DETAILS '-5 " INSTALL 12"H N.T.S. M CONCRETE PEDESTAL DETECTABILE WARNING NOTES: N 21" N.T.S. 3 8" 0 STAINLESS 1. THE DETAILS PROVIDED ARE NOT DRAWN TO SCALE. THE M VACUUM UNIT QUANTrITY OF DOMES DEPICTED ON THE DETECTABLE ¶� STEEL BOLT WITH 50%-65% OF BASE DIAMETER WARNIING FIELD (THE DOMES AND THE ENTIRE 2.4" LEVEL PLAN VIEWNUTS AND R� �m SURFAICE) IS FOR ILLUSTRATION ONLY. 6"gold anodized p 4000 P.S.I. AIR WASHERS (TYP.) ( � DETECTABILE WARNING FIELD DIMENSIONS aluminum ball I ENTRAINED CONCRETE II uV C=_;Lw��G,d 2. THE SIZE OF THE DETECTABLE WARNING FIELD SHALL BE r,1 SLAB BY CONTRACTOR 2'-0"' IN THE DIRECTION OF TRAVEL AND SHALL EXTEND (6" THICK) WHITE BACKGROUND ��U M 2�26 �I THE FFULL WIDTH OF THE CURB RAMP OR FLUSH SURFACE. o 16 '�' SOUTHOLD TOWN C� EXCLWSIVE OF SIDE FLARES. ? o ro &fe DOME ALItGNMENT Singfe sheave truck, _ _3. THE FROSS OF DOMES SHALL BE ALIGNED TO BE T ®� cast aluminum revolving type ;I I 0.9"-1.4" PERPENDICULAR OR RADIAL TO THE GRADE BREAK BETWEEN SIDE VIEW FRONT VIEW PARKIN BLACK LETTERS/ PIANNINGFOARD THE RAMP LANDING OR CURB RAMP AND THE STREET. BORDER 4. DOME DOMES ARE ARRAYED RADIALLY THEY MAY DIFFER IN `"" O o DOME Af SECTION DOME DIAMETER AND CENTER-TO-CENTER SPACING WITHIN T1 1/2" ASPHALT IMPREGNATED °o DOME SECTION THE RANGES SPECIFIED ON THIS SHEET. TRASH RECEPTACLE DETAIL (1)5116"dia.halyard(#10 poly) o NOTE: DO NOT INSTALL w o COLOR REQUIREMENTS VACUUM UNIT WITHIN 20 FT. PREMOLDED FILLER z o 0 24" 5. THE DETECTABLE WARNING FIELD SHALL VISUALLY CONTRAST NTS OF FUEL DISPENSER OR 10 I ° 1.6"-2.4" FROM ADJACENT WALKING SURFACES (DARK ON LIGHT OR FT. OF FUEL TANK FILL PLAN VIEW �' o SITE ADDRESS. LIGHT ON DARK) = DETECTABILE WARNINGS LOCATIONS o co o d 6. DETECTABLE WARNINGS SHALL BE LOCATED $O THAT THE M m PROPOSED CONVENIENCE STORE " O O O O O O O O EDGE OR ON CURB RAMP TYPE 1 AT LEAST ONE CORNER 1" x 6" FLUSH 6" x 6" PVC POST (TYP.) ' Single Sheave Truck Detail ¢ �— WITH FILLING STATION :I OF THiE WARNING FIELD NEAREST TO THE ROADWAY IS 6" TO VERTICAL PANELS (2)Swivel snaps with Revolving truck VACUUM UNIT I €" 0 000000000 - ci 0 8" FROM THE FRONT OF CURB OR THE EDGE. 1" x 6" TOP RAIL (TYP.) vinyl covers cv Cast aluminum body O o 0 0 0 0 0 0 0 0 1 ~ Stainless steel ball bearings BICYCLE PARI�INC� SIGN 7400 MAIN ROAD O O O O O O O O O O `1' C. Cast aluminum spindle `s,14' MATTITUCK, 0 0 0 0 0 0 0 0 0 , TOWN OF SOUTHOLD II DOME (TYP.) (SEE NOTE 1) •EDGE OF FIELD (1)9"Cast aluminum cleat 00 N.T.S. I SUFFOLK COUNTY, NY 11952 '6) DOME SPACING' � !" s° o °�' DISTRICT: 1000 BLOCK: 07 r z D (5) 1/2"-13 NC4 !ll ADA DETECTABLE WARNING DETAIL m x3-1/2" LG GROUND SECTION: 122 LOTS: 1 & 3.2 1 0 0_ ° WEDGE ANCHOR I "DO NOT ENTER" SIGN 30" w o tEI BEHIND FACING 3/8" 0 STAINLESS CALE.' BOLTS (FURNISHED INSTALL 12"H STEEL BOLT WITH �— AS SHOWN HPE# EMP021-01 o ` " CONCRETE OPPOSITE DIRECTION N.T.S;. N •� 4? AND INSTALLED BY ygg I o, p:: NUTS AND Spun aluminum flash collar T, cro CONTRACTOR I 10 9 23 EMP021-01-SP.3a 2'-0" ) slc WHITE THERMOPLASTIC , SI, PEDESTAL (WHERE APPLICABLE ATE.' DWG TYP. 3000 PSI concrete m -- - WASHERS (TYP.) DRAWN BY. / / 1'-0" STOP LINE ° - SEE SITE PLAN) PROPERTY LINE (supplied by others) v ° 'l LD CHECKED BY.' MUTCD SIGN R1-1C CT • 1r ° ° WHITE LETTERS Tom. 0 0 Hardwood wedges es) LQ GRADE ° r) u O RED BACKGROUND ° (supplied b others o D DETAIL SKEET GRADE c!A o 0 iv � m Dry sand tightly tamped _ (I if o cl� 1" x 6" BOTTOM (supplied by others in I 3'-0 x3'-0" v 1/2" SLOPE JJ) w RAIL (TYP.) of Foundation sleeve-16 ga o o - o -- T o galvanized steel o —% FRONT ELEVATION z o 1 CONCRETE FOUNDATION, TYP. r M g p Z) v COMPACTED SUBGRADE, TYP. Steel centering wedges ° 7-3/4- RIGID CONDUIT 24" oN. BELOW FIN. GRADE I o 8 MIS SEE PLAN r', 6" GRAVEL BASE �"` UNDER PAVED AREAS, BY i� w o 1 o ;, ,,} 3/16"Steel base late CONTRACTOR o • / Z -�1=-I�- 6" w Q w 99 �r�®� 99 SIGN SHEET NO. THERMOPLASTIC PAINTED a PVC FENCE DETAIL 3/16"Steel sup n%spikee 12' VACUUM STATION DETAIL SIGN �7 wo N.T.S. 16^ (CONTRACTOR TO VERIFY UNIT MODEL W/ OWNER) N.T.S. D TRAFFIC ARROW O ! —SITE w 3/4"Lightning ground spike 10 30„ NTS (WHITE) STOP PAR DETAIL W FLAG POLE DETAIL N.T.S. N.T.S. NTS REV. 3 OF 10 1'rtl�l�ti}"OEIIL' ptnprilm filly MANHOLE FRAME W/ l'.ir9lt"i�f-4 'FfitRittt-i� 11' 4" THICK CONC. BLOCK OR COVER REFER TO 8" CONC. TOP TO DRAINAGE SCHEDULE SUPPORT H-20 1 ' TOP COURSE FULL SHOULDER HIGH ■r ' , PRECAST CONC. COLLAR TO BRING MANHOLE TO GRADE FOR CORRESPONDING VEHICULAR LOADING OVERCUT r -Oil GRATE/COVER 4000 P.S.I. ® 28 POINT INFORMATION DAYS 1/4"/FT SEE NOTE BELOW �• FINISH PAVEMENT ) f Z x 1 _ Q ITEM 404.098101 2" NGINEERING - l - ITEM 404.198901 3 - ?` 1 1._ ,-> ,-! i. ' 1 N .,t_.�y > ii EXISTING PAVEMENT tJ 6, _ '"-�' . 01. FILTER FABRIC 1860 WALT WHITMAN ROAD 25' - TO LINE ��'-� � � �x_ `?\�� ITEM 404 258901 ( N TWO 3" LAYERS) ITEM 0' -., _- dam - 407 0102 „I� __. _... _ f � f r V� i 600 STRUCTURE __ J >> C, BINDER COURSE TO HAVE 1 I°- -1)' ITEM 304.10119917 6" f _ .._-____-_________._s,• _...-.� _._.._-�� f -;��- � ., `�.� 19.5mm SIZE STONE PER ( ) MELVILLE,NY 11747 ( 1 ) 77-4320 FAX. ( 1 ) 77-4321 BACKFILL WITH 1"-1 1/2" �' i_�=„ v� _ %{ , NYSDOT SPECIFICATIONS ITEM 203.01 7 567 II��I'11) _ }�:+I.°�i{) f'-if + 5'-19" _-._ - 0 �,> w f _., GRAVEL MATERIAL (CLEAN ry cn �` 1'-' -- - - - - - - - - - - - - ALL PHASES OF ENGINEERING DESIGN, SAND MAY BE USED FOR O Q - SURVEYING,CODE CONSULTING, > w BACKFILL WHERE WELL y 3 = Q ��{ } h• I f DRAINING SOILS ARE TYP. + zJ -� - ' - TYPICAL SECTION ASPHALT PAVE ZONING ANALYSIS&BID SPECIFICATION PRESENT AS CONFIRMED ` _,; ^ o � �_� PAVEMENT 1 I BY GEOTECH ENGINEER) �-= u CONSTRUCTION IN NYSDOT R.O.W. - D www.HPEng.com v _? NTS 0,10' 0 - CHRIS M. TARTAGLIA ,� `; > . , �`, ASPHALT PAVEMENT CONSTRUCTION , _, 1 ` 6' MIN. PENETRATION xn2, , SANDV&VIRGIN of ITEM DESCRIPTION 1'0. 'r `M'"'F•k 203.01 UNCLASSIFIED EXCAVATION AND EMBANKMENT Q' R ec wr.a� 2' MIN. 1 . i;' 4Y°k:AI�1`;(:E t.bLIF?`+1 SEPARATION TO 304.101 19917 SUB BASE COURSE TYPE 101 1 -2 (:[�n+i`Pt'tE err :}. �,?- 1'2" 1:111�1:1� C'C)I!ItiF. GROUND WATER PERFORATED Q PRECAST 404.258901 25 F9 BASE COURSE, 60 SERIES COMPACTION ® INTERCONNECTING PIPE f,r•4e tlfa{5 s4 fINi: cu!,krir' ~ SEE DRAINAGE SCHEDULE CONC. RINGS 404.198901 19 F9 BINDER COURSE, 60 SERIES COMPACTION r- II W SC�n +Tcf (1wl!. ���y rl,t,l.11i�, 1,�.'•ba+RS1 FOR PIPE INVERT DRYWE L DETAIL 404.098101 9.5 F1 TOP COURSE, 80 SERIES COMPACTION 2�4 STONE 131_1:N11 0k N.T.S. 403.218902 ASPHALT (CONCRETE - TRUING AND LEVELING COURSE a782�g !v' HARDWARE SCHEDULE FRAME & COVER: CAMPBELL FOUNDRY #12038 407.0102 DILUTED TACK COAT TOWN OF SOUTHOLD FRAME & GRATE: CAMPBELL FOUNDRY #2203 490.30 MISCELLANEOUS COLD MILLING OF BITUMINOUS CONCRETE PR NGINEER CONTRACTOR TO USE THESE ITEMS OR APPROVED EQUAL. 490.40 MISCELLANEOUS COLD MILLING OF PORTLAND CEMENT CONCRETE NEW YORK LICENSE No. 078209 ASPHALT ROADWAY DETAIL 502.44200011 SAW CUTTING PORTLAND CEMENT CONCRETE � (FOR USE IN TOWN R.O.W.) 633.11 CLEANING EXISTING PAVEMENT AND/OR SHOULDERS LAWRENCE D. 0 BRIEN N.T.S. 633.05040008 CLEANING, SEALING AND FILLING JOINTS AND CRACKS CONCRETE CLEANOUT BOX NOTES: d NAH ME FRAME AND COVER( TACK COAT REQUIRED BETWEEN ALL LIFTS REGARDLESS WHEN PLACED, ALL COLD JOINTS SHALL BE SEALED W NEE R-6400AS OR EQUIVALENT) FINISHED GRADE �+ / APPROPRIATE ITEM # WHERE THE EXISTING PAVEMENT CROSS-SLOPE IS DIFFERENT FROM 1/4 PER FOOT, THE PROPOSED PAVEMENT SLOPE SHALL MATCH THE EXISTING PROVIDED THE SLOPE WILL BE 3/16"/FT. MINIMUM AND 3/8"/FT. MAXIMUM. WHERE A SLOPE WITHIN 'THIS RANGE CANNOT BE OBTAINED, RESURFACING OF THE EXISTING ROADWAY TO CORRECT ITS CROSS-SLOPE MAY BE REQUIRED BY THE REGIONAL PERMIT ENGINEER. PROFESSIONAL ENGINEER NEW YORK LICENSE No. 082537 UNLESS APPROVED BY ALL AGENCIES HAVING JURISDICTION, THESE PLANS ARE NOT TO BE UTILIZED r FOR CONSTRUCTION. OWNER/ CONTRACTOR ARE I QR�nOQ�n�fl , 18'• Pia.I C.K.P. RESPONSIBLE FOR CONFIRMING ALL REQUIRED AGENCY APPROVALS HAVE BEEN SECURED PRIOR TO p nn COMMENCEMENT OF WORK, WHETHER DESCRIBED ON d w z THESE PLANS OR OTHERWISE. �n�n�OM If � F50g REVISIONS �IIItO��� CPP w Lu CL t a(n z REV NO. DATE REVISION L fl d -.j of. Ju---- m NYSDOT GENERAL NOTES 1 10124123 MISC. REVS P L A N o1 2 512JI24 PER TOWN COMMENTS CAST IRON FRAME 6 CRATE - CAMPBELL CONTRACTOR TO CONTACT ADS (ADVANCED DRAINAGE SYSTEM INC.) GRAPE FOUNDRY PATTERN l 2541 OR APPROVED 300 RIVERSIDE DRIVE, 1. BEFORE CONSTRUCTION, THE CONTRACTOR SHALL COORDINATE WITH STATE PERMIT ENGINEER REGARDING APPROPRIATE LOCATION FOR 3 712JI26 REV SITE LAYOUT EQUAL. COLUMBUS OHIO 43221 SNOW STAKES SLEEVES. TEL. 800-821-6710 2. AFTER CONSTRUCTION, SIDEWALKS AND RAMPS MUST BE EVALUATED) FOR COMPLIANCE WITH CURRENT ADA STANDARDS. THE PERMITTEE OR ter+ TO OBTAIN SPECIFICATION MANUAL FOR DIMENSIONS, INSTALLATION DETAILS AND HIS DESIGNATED "DESIGNER OF RECORD" SHALL FIELD VERIFY THAT THE PEDESTRIAN FEATURES (RAMPS, SIDEWALK, ETC.) WERE -- ASPHALT PAVEMENT CONSTRUCTED TO CURRENT ADA STANDARDS OUTLINED IN NYSDOT 'SPECS SECTION 608 AND RELATED STANDARD SHEETS. SUBMIT REQUIRED PART NUMBERS FOR ADS N-12 CORRUGATED PLASTIC PIPING (CPP) DOCUMENTATION TO THE STATE PERMIT ENGINEER BEFORE THE WOFRK CAN BE ACCEPTED AS COMPLETE AND THE PERMIT BE CLOSED. THE ,�: ,::;'s• L8 Pia. C.Y.P. FEATURES THAT DO NOT COMPLY WITH ADA REQUIREMENTS UPON COMPLETION WILL REQUIRE REMOVAL AND RECONSTRUCTION. ' ,• ADS STORM PIPING CLEANOUT 3. THE CONTRACTOR SHALL CLEAN EXISTING DRAINAGE BASINS ALONG AND IMMEDIATELY ADJACENT TO THE NY SITE FRONTAGE DURING AND 2 -6 N.T.S. AFTER CONSTRUCTION AS ORDERED BY THE STATE ENGINEER. 4. REPAIR EXISTING SHOULDER, SIDEWALK AND CURBING AS ORDERED BY STATE ENGINEER. 5. ANY SIDEWALK PANELS OR CONNECTING PAVEMENT THAT HAVE SETTTLED WITH A GREATER THAN J" LIP OR CRACK OVER I" WIDE SHALL BE REPLACED TO MEET ADA REQUIREMENTS. 'r t' 6. CONSTRUCTION MATERIALS AND EQUIPMENT SHOULD BE REMOVED FROM THE NYSDOT ROW AT THE END OF EACH WORKDAY. MATERIALS i.-b.. --��-- - - 3.Oi00 P.S.I. PRECAST ,+ ALLOWED TO REMAIN ON SITE MUST BE STORED OUTSIDE THE VEHIICLE CLEAR ZONE. 1 t CONICRETE BOX AS %TC. '� MAX. 7. REMOVAL OF THE EXISTING CONCRETE CURB SHOULD BE DONE FR(DM THE BACK SIDE TO MINIMIZE ANY DAMAGE TO THE EXISTING ,r'.'' •,:*: ';:. ,` BY 'SUFFOt.K CEMENT Yell " MIN. PAVEMENT. THIS INVOLVES PULLING THE CURB OUT FROM THE BACIK AND POURING NEW CURB UP AGAINST THE EXISTING PAVEMENT. OR ,APPROVED EQUAL. �' TGH 8. ALL NEW OR RELOCATED SIGNPOSTS MUST BE INSTALLED IN PVC SLEEVES. TO1"IR 9. SNOW STORAGE STRIP AND SIDEWALK RESTORATION MUST MATCH THE ONES IN THE NEIGHBORHOOD AND NOT DEGRADE THE AESTHETIC 6" 4'-0" 6" R�AOWA ""' VALUE. 10. PAVEMENT RESTORATION SHALL BE IN KIND. COMPOSITE PAVEMENT RESTORATION SHALL BE TAKEN TO EXISTING LONGITUDINAL JOINT. IF ANY DAMAGE OCCURS TO CONCRETE PANEL, THE CONTRACTOR WILL BE RESPONSIBLE TO REPLACE THE WHOLE PANEL. TOWN OF SOUTHOLD 11.12. ALL MINIMUM COLD JOINTS TO WIDTH OF SBE PHALT RESTwRAHIOOT OULIDEDBSE4' FOR PROPER COMPACTION. ADD 1 FT OVERCUT FOR TOP COURSE. PRECAST CATCH BASIN DETAIL ,;� 13. TACK COAT IS REQUIRED BETWEEN ALL LIFTS AND JOINTS, REGARDLESS OF WHEN PLACED. THE EDUCATION LAW OF THE STATE OF NEW YORK PROHIBITS ANY AMA OR PCC 14. COMPOSITE PAVEMENT RESTORATION SHALL BE IN ACCORDANCE WITH THE CURRENT REGIONAL PAVEMENT REPAIR GUIDE SHEETS. PERSON ALTERING ANYTHING ON THESE DRAWINGS AND/OR THE (FOR USE ON-SITE) PAVEMENT �n 5- 4- 15. THE THICKNESS OF CURB RAMPS SHOULD BE A MINIMUM 6" AND THEY SHOULD INCLUDE WIRE FABRIC REINFORCEMENT WITH 3" OF TOP ACCOMPANYING SPECIFICATIONS, UNLESS IT IS UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. WHERE SUCH N.T.S. COVER. THE RAMPS SHALL HAVE A LEVEL 5'X5 LANDING IN THE SIIDEWALK. ALTERATIONS ARE MADE, THE PROFESSIONAL ENGINEER MUST SIGN CURB16. THE CURB RAMPS SHALL BE ORIENTED TO DIRECT THE PEDESTRIANIS STRAIGHT TO THE DESTINATION RAMP ACROSS THE DRIVEWAY. AND SEAL, DATE AND DESCRIBE THE FULL EXTENT OF THE 17. APPROVED ITEMS CAN BE VERIFIED AT WWW.DOT.NY.GOV/PIC. STANDARD SHEETS ARE AVAILABLE AT: STANDARD SHEETS (US CUSTOMARY) ALTERATION ON THE DRAWING AND/OR IN THE SPECIFICATIONS. SUBBASE (SEE PLAN (NY.GOV). FOR MORE INFO. PLEASE GO TO WWW.DOT.NY.GOV/PERMITrS. (NYS EDUCATION LAW SECTION 7209-2) TYPICAL SECTION) - - - - - -t 18. ANY UTILITY WORK PROPOSED IN STATE HIGHWAY RIGHT-OF-WAY WALL REQUIRE SEPARATE APPLICATION AND SUBMISSION OF RESTORATION- _ _ PLANS. FOLLOW THE GUIDELINES OF OUR UTILITY HANDBOOK, BLUE BOOK TITLED, 'REQUIREMENTS FOR THE DESIGN AND CONSTRUCTION OF TYPE V'G UNDERGROUND UTILITY INSTALLATIONS WITHIN THE STATE HIGHWAY RIGHT-OF-WAY'. THE APPLICANT SHOULD CONTACT MR. WOLFF JOSEPH (VERTICAL FACED CURB WITHOUT CURB ANCHOR) (631-420-4270, WOLFF.JOSEPH®DOT.NY.GOV) FOR FURTHER DIRECTIONS REGARDING UTILITY HIGHWAY WORK PERMIT (HWP) APPLICATIONS. (SEE NOTE 4) THE UTILITY HWP ISSUANCE IS SUBJECT TO ISSUANCE OF THE HWP' REQUIRED FOR SITE WORK. 19. ALL PROPOSED ROAD IMPROVEMENTS DETAILED IN THE SITE PLANS MUST COMPLY WITH THE LATEST VERSIONS OF AASHTO, ADA, NATIONAL MANUAL OF UNIFORM TRAFFIC CONTROL WITH THE NYS SUPPLEMENIT (MUTCD), NYSDOT HIGHWAY DESIGN MANUAL, AND THE POLICY AND STANDARDS FOR THE DESIGN OF ENTRANCES TO STATE HIGHWAYS (('DRIVEWAY DESIGN POLICY'). ROAD IMPROVEMENT PLANS MUST PROVIDE ALL APPROPRIATE NYSDOT STANDARD DETAILS AND NYSDOT STANDAFRD ITEM NUMBERS. RE PERITTED ON WEEKENDS CURB NOTES 20 HOLIDAYS.S NIGHTTIME HTTIME LANE CLOSINGS UST BE OPEN TO IWILBLE NOTFORE BE PERMITTED W THiOUT PRIOR APPROVA10 AM AND AFTER' 3 PM. NO LANE L FROM INGSAT E STATE PERMIT INSPECTOR.OR NOV 16 2026 SOUTHOLD TOWN 1. USE CURB AND CURB AND GUTTER MEETING THE MATERIAL AND PLANNING DOARD CONSTRUCTION REQUIREMENTS OF SECTION 609 OF THE STANDARD SPECIFICATIONS. 2. CURB ANCHOR(NEW CONSTRUCTION)THIS DETAIL SHOWS PLACEMENT OF CURB ASPHALT ANCHORS. PUSH-IN TYPE ANCHORS MAY BE USED. 8'l Ill WEARING 3. CURB TYPES M150A,VF150A,AND MIOOA REQUIRE CURB ANCHOR. CURB AND SITE ADDRESS. SURFACE GUTTER TYPES VF150G AND M100G REQUIRE ANCHORS WHEN PLACED ADJACENT TO CONCRETE PAVEMENT OR SHOULDER. PROPOSED CONVENIENCE STORE FINISH WITH FILLING STATION GF1'+DE .�1 H 4. WHEN VERTICAL FACED CURB LESS THAN 8"WIDE IS USED WITH CURB BOXES CUI,CU2,AND CU3 AND CONCRETE SIDEWALK IS PLACED ADJACENT TO THIS W771� CURB,SEE STANDARD SHEET MISCELLANEOUS CURB DETAILS FOR CURB BOX 7400 MAIN ROAD ;;p'."l,1;;!•�'! .4 JOINTS. MATTITUCK, NYSDOT r ITEM NUMBERS TOWN OF SOUTHOLD: ='' �• ., +- ;"`3 5. USE WITH CURB BOXES,CMI,CM2,AND CM3. SUFFOLK COUNTY, NY 11952 .~+•ram:: 'r 6. NYSDOT PAY ITEM#609.0401. CAST IRON IMBEDDED DETECTABLE WARNING IUNITS 608.21000003 TOPSOIL-ROADSIDE 610.1402 DISTRICT: 1000 BLOCK: 07 ;;••:�. r• ~' NYSDOT CURE DETAIL • TURF ESTABLISHMENT-ROADSIDE 610.1601 SECTION: 122 LOTS: 1 & 3.2 • SUB BASE COURSE TYPE 1 304.10119917 •^ 3.1000 P.S.T. N.T.S. 25 F9 BINDER COURSE ASPHALT, 80 SERIES' COMPACTION 404.258901 SCALE. AS SHOWN HPE# EMP021-01 9" CONCRETE 19 F9 BINDER COURSE ASPHALT, 80 SERIES COMPACTION 404.198901 0 2+8 DAYS 9.5 F1 TOP COURSE ASPHALT, 80 SERIES COMPACTION 404.098101 10/9/23 DWG # EMP021-01-SP.3a • DILUTED TACK COAT 407.0102 RAD WN BY. Lp CHECKED BY. CT • CLEANING AND FILLING ASPHALT JOINTS AND CRACKS 633.05040008 TOWN OF SOUTHOLD CLEANING EXISTING PAVEMENT AND/OR SHOUILDERS 633.11 TITLE • UNCLASSIFIED EXCAVATION AND EMBANKMENT 203.01 TYPE "A" COMMERCIAL CURB DETAIL MISCELLANEOUS COLD MILLING OF BITUMINOWS CONCRETE 490.30 •(FOR USE ON-SITE & R.O.W.) MISCELLANEOUS COLD MILLING OF PORTLAND CEMENT CONCRETE 490.40 ���� y-�E • SAWCUTTING PORTLAND CEMENT CONCRETE 502.44200011 �i N.T.S. PAVEMENT MARKINGS, SYMBOLS 619.002 • CONCRETE SIDEWALK 608.01000010 �� • SAWCUTTING ASPHALT & CONCRETE PAVEMENIT 203.50140363 • CONCRETE CURB RAMP 608.010500009 • CONCRETE CURB (VF6) 609.0401 (NYSDOTIMISC. ) SHEETI%Q--NO•' p O � O REV. 3 OF 10 GENERAL NOTES: CURB RAMP NOTES: 5'-0" MiN 54" 5'-01, MTN HIGH su SAW CUT EXISTING ASPHALT 1. THESE SHEETS ARE iN ACCORDANCE WITH THE AMERICANS WiTH DISABILITIES ACT 19. THE MINIMUM WIDTH OF A CURB RAMP SHALL BE 44". (ADA), ANDi THE REQUIREMENTS OF THE 2011 PROPOSED ACCESSIBILITY GUIDELINES FOR OR CONCRETE DRIVEWAYS PEDESTRIAN FACILITIES IN THE PUBLIC RIGHT Of WAY (PROWAGI. 20. MUM THE GRADE (RUNNING SLOPE) OF A CURB RAMP SHALL BE A MINI OF 5%. THE 5r SIDEWALK GRADE FOR DESIGN AND LAYOUT SHALL BE A MAXIMUM OF 7.5%. THE GRADE FOR ADA POINT �lp�H 2. DIMENSION's SHOWN IN THE DETAILS AS DESIGN NEAND FIELD LAYOUT. FA ILITIES HALL NETTBE CONSTRUCTED O DS AND ES GATE WITH VAS ARE THE LUES ITS N ES" 21. WHERE EXISTINGCONDTY AND ITIONS ONS DO NOT ALLOWRK ACCEPTANCE HE CONST BE A RUCTION TION FMUM OF 3A AMP W f 6", Ij T RUC 0 CURB R WITH 0'MiN�1e DESIGNON S LAYOUT, ANDHER ACCEPTANCE INFORMATION PEDESTRIAN EFACILITIES"ON ICAVAILABL ELEMENTS ON FOR E THE TO GRADE EXCEED 15'-1" FORSLOPE) DESIGN ANDOFIE FIELD LAYOUT.THE THE RAMPLENGTH LENGTH SHALL NOT NOT BE REQUIRED ENGINEERING NYSDOT HIGHWAY DESIGN MANUAL CHAPTER 18 WEBSITE. REQUIRED TO EXCEED 154" FOR WORK ACCEPTANCE. QOS� 3. NOT ALL FACILITIES CAN BE CONSTRUCTED TO MEET THE DESIGN STANDARDS. 22. THE CROSS SLOPE OF THE CURB RAMP SHALL BE AS FLAT AS POSSIBLE AND STILL FACILITIES THAT CANNOT BE CONSTRUCTED TO MEET THE DESIGN STANDARDS SHALL BE PROVIDE POSITIVE DRAINAGE. THE CROSS SLOPE OF A CURB RAMP SHALL BE 1.5% MAXIMUM DETAIL "A" CONSTRUCTED TO MEET THE STANDARDS TO THE GREATEST EXTENT PRACTICABLE. FOR DESIGN AND LAYOUT, AND 2% MAXIMUM FOR WORK ACCEPTANCE.SEE NOTE 12 FOR 1860 WALT WHITMAN ROAD Q�• 21j NONSTANDARD FEATURES SHALL BE JUSTIFIED PER HIGHWAY DESIGN MANUAL CHAPTER 2. EXCEPTIONS. WHERE THE EXISTING ROADWAY GRADE EXCEEDS 27 THE CURB RAMP MAY BE ACCESSIBLE PASSING SPACE TRANSITION EXHIBIT 2•-15A. WARPED ACCORDING TO THE DETAIL ON SHEET 8 OF 9 TO TIE INTO THE DROP CURB. ONE SIDE TAPERS SUITE 600 FF�ipj �1A�,, ��'• 4. TO CHECK FIELD LAYOUT AND TO VERIFY WORK ACCEPTANCE, ALL SLOPES AND GRADES 23. RAMP SiDE OPTIONS ARE DETAILED ON SHEET 3 OF 9 FOR USE WITHIN THE BUFFER 5'-0" MIN 5'0" 54" MiN MELVILLE,NY 11747 qy WILL BE MEASURED WITH A 4 FOOT LONG DIGITAL LEVEL USING AT LEAST TWO READINGS. ZONE. WHERE A PEDESTRIAN CIRCULATION PATH CROSSES THE CURB RAMP, FLARED SIDES WHERE THE\ NOT \\ SLOPE) WIILLRBEDINGS ME SURED' THE ALONGMTHEUREMENTS CENTERLINELANDEOFFSETGED. GRADE 12" TO 18"(FROMNTHE MAXIMUMHALL EFOR WORK INSTALLED ACCEPTANCE..MAXIMUM SLOPEEOFFFLAREDOSIDES ISNME STARED PAAND RALLELOTO AN 1 % ° (516)777-4320 FAX: (516)777-4321 F 9 CENTERLINIE. CROSS SLOPES WILL BE MEASURED PERPENDICULAR TO CENTERLINE AT 5' TO THE CURB LINE. J \ S` 10' INTERNALS. 5. GRADES SLRUNNING ARESLOPES) ARE PE MEASURED DICULAR TO DI E CDI ON OF PEDESTRIAN TRAVTRAYEL. 24 TO MATCH EXISTING NTE RAIN,UNLESS TERWSEDSHOWN OW OIN H THE CO. THE BACKSIDE OF A PARALLEL RAMP SHOULD BE GRADED TO A NTRACSTDDOCU UM SLOPE EN S � �' ALL PHASES OF ENGINEERING DESIGN, F Fp D SURVEYING,CODE CONSULTING, 6. JOINTS BETWEEN SIDEWALKS, CURB RAMPS, TURNING SPACES AND ROADWAYS SHALL BE BACK CURB MAY BE INSTALLED. SEE DETAILS ON SHEET 3 OF 9 AND SHEET 9 OF 9. ZONING ANALYSIS&BID SPECIFICATION �F y�� \ FLUSH AN© FREE FROM ABRUPT VERTICAL CHANGES GREATER THAN I/4". VERTICAL SURFACE 25. DEPARTMENT PREFERENCE IS TO INSTALL TWO CURB RAMPS AT A STREET CORNER THAT pjQl (SEE DRIVEWAY NOTE 11) P \ DISCONTINIUITIES BETWEEN �I/4" AND %Z' SHALL BE BEVELED WITH A SLOPE NOT STEEPER SERVES BOTH CROSSINGS.WHERE EXISTING PHYSICAL CONSTRAINTS PREVENT TWO CURB THAN 1:2. THE BEVEL SHALL BE APPLIED ACROSS THE ENTIRE JOINT. SEE DETAIL ON RAMPS FROM BEING INSTALLED AT A STREET CORNER THAT SERVES BOTH CROSSINGS, A SHEET 2 CE 9. SINGLE DIAGONAL CURB RAMP WILL BE PERMITTED TO SERVE BOTH PEDESTRIAN STREET DETAIL "B" www.HPEng.COm \ 7. SiDEWALKSi ARE CONNECTED TO ROADWAYS BY EITHER BLENDED TRANSiT10NS OR CURB CROSSINGS. ACCESSIBLE PASSING SPACE TRANSITION sjp �Pv ROADWAY LIENDED ILEVE L THAT HIAVENS ARE A MAXIMUMNECTIONS GRADE (RUNNING SLOPE)N THE SOFEWALK 5%,AND VTEL AND THE RANSITIONS BOTH SIDES TAPER j� c { \ s,0 F�vgl� CORNER ANGLE IN OF GREATER TTHAN 5% ARE CONSIDERED CURB RAMPS. TURNING SPACE AND CLEAR SPACE NOTES: C11RI:7 C1V1 M. TARTAGLIA SIDEWALK RAMP \ \ jS• MIN Z��C 8. AND DETEDETACTABLE WARNINGS. INGS.HEET ZEEOADDDITIO ADDITIONAL 'DETECTABLE EENTATIONCURB RAMPS AND BLENDED TRANSITIONS MAY REQUIRE THE TAD NOTES" ON THIS SHEET,ALLATION OF 26' SPACE SHALL WHERE A NBE PROVIDED GE IN iAT THE ION IS RBA ER OR THE ED TO UTOP ZOFA CURB BRAMP PAS APPLICABLE. �V A TURNING aT 1���/t/�O LAYOUT VARIES (TYP.) \ /I7 TURNING SPACES SHALL BE PERMITTED TO OVERLAP CLEAR SPACES. MAf�kT '�� \Q,r 9. VERTICAL ALIGMENT SHALL BE GENERALLY PLANAR. GRADE BREAKS WITHIN THE 27, WHERE HERE ARE NO VERTICAL CONSTRAINTS AT THE BACK OF SIDEWALK,(E.G" - PEDESTRIAIN ACCESS ROUTE SHALL BE PERPENDICULAR TO THE DIRECTION OF TRAVEL AND Q \ VERTICAL CURB, BUILDINGS, FENCES) THE TURNING SPACE DIMENSIONS SHALL BE 4'-0" x ,0 SHALL NOT BE ROUNDED. 4'-0" MINIMUM. WHERE THE TURNING SPACE iS CONSTRAINED AT THE BACK OF SIDEWALK, ' p�• \ THE TURNING SPACE SHALL BE 4'-C X 5'0" MINIMUM. THE 5'-0" DIMENSION SHALL BE pESIGN ELEMENT TOLERANCES NJ GjI• \ ��G �,P�rC• 10. MATERIAL D F ERENT'DIN)HS THE SHOWN CNTR CT DOCUMENTS. ELEMENT SHEETS ARE TYPICAL MINIMUM VALUES AND MAY BE PROVIDED PERPENDICULAR TO THE CONSTRAINT. DESIGN AND FIELD LIMIT FOR WORK r- oG + • \\\ y �Q�Q �1 P��`'� 28. TURNING DIRECTSPACES WHILE SHALL PNOT BE DESIGNED POSITIVE WITH CROSS DRAINAGE. SLOPE THE GREATERUM THAN OSS S1.5%LOPE IN LAYOUT SIDEWALK CROSS SLOPE - SE NOTE 2 LAt OUT LIMIT ACCEPTANCE CCE2.0%P AN EANY ` �t 11. SIDEWALK GRADE (RUNNING SLOPE) SHALL NOT BE DESIGNED TO EXCEED 4.5%. EXCEPTION, WHEN MATCHING INTO EXISTING SIDEWALK OR WHEN THE HIGHWAY GRADE IS STEEPER. WHEN WORK ACCEPTANCE IS 2.0%. A NONSTANDARD FEATURE JUSTIFICATIN IS REQUIRED WHERE HIGHWAY GRADE IS GREATER THAN 5%, THE SIDEWALK GRADE SHALL NOT EXCEED THE TURNING SPACES EXCEED 2.0% IN ANY DIRECTION. SIDEWALK GRADE (RUNNING SLOPE) - SEE NOTE 11 4.5% MAX. 5.0% MAX. 0782 Sfp HIGHWAY GRADE. CURB RAMP GRADE (RUNNING SLOPE) - SEE NOTE 21 7.5% MAX. 8.3% MAX. V I S F�Q �5 Q'O 12. THE CR055 SLOPE Of PEDESTRIAN ACCESS ROUTES SHALL BE 1.5% MAXIMUM FOR 29• BEYOND THE BOTTOM GRADE BREAK, A CLEAR SPACE OF 4'-0" x 4'-0" MINIMUM SHALL BLENDED TRANSITION GRADE (RUNNING SLOPE) - SEE NOTE 7 4.5% MAX. 5.0% MAX. �t BE PROVIDED WITHIN THE WIDTH OF THE PEDESTRIAN CROSSWALK, AND OUTSIDE THE M DESIGN AND LAYOUT, AND 2% MAXIMUM FOR WORK ACCEPTANCE. THE FOLLOWING EXCEPTIONS PARALLEL VEHICLE TRAVEL LANE. THE CLEAR SPACE MAY OVERLAP TURNING SPACES, ALL VALUES SHOWN ON THE 608-01 STANDARD SHEETS REFER TO DESIGN AND FIELD LAYOUT LiMiTS. PR NGINEER \q�' ARE ALLOWED: DETECTABLE WARNING SURFACES, AND DROP CURBS. NEW YORK LICENSE No. 078209 FOR ADDITIONAL REQUIREMENTS AND TOLERANCES, SEE "CRITICAL ELEMENTS FOR THE DESIGN, LAYOUT, A. WHEIRE PEDESTRIAN STREET CROSSINGS ARE PROVIDED AT INTERSECTIONS AND CONSTRUCTION OF PEDESTRIAN FACILITIES" AVAILABLE ON THE NYSDOT HIGHWAY DESIGN MANUAL WITHOUT YIELD STOP CONTROL OR WHERE THERE IS ANY TRAFFIC SIGNAL CHAPTER 18 WEBSITE. LAWRENCE D. O'BRIEN WITHOUT A FLASHING NG RED, THE CROSS SLOPE OF A PEDESTRIAN ACCESS ROUTE DETECTABLE WARNING NOTES: CONTAINED WITHIN A STREET CROSSING SHALL BE 4.5% MAXIMUM FOR DESIGN AND LAYOUT, AND 5% MAXIMUM FOR WORK ACCEPTANCE. 30. PEDESTRIAN LE ARNINGRSURFACES SHALL BE PROVIDED AT THE FOLLOWING LOCATIONS ON B. WHERE MIDBLOCK PEDESTRIAN STREET CROSSINGS ARE PROVIDED, THE CROSS QP SLOPE OF A PEDESTRIAN ACCESS ROUTE CONTAINED WITHIN A MIDBLOCK A. CURB RAMPS AND BLENDED TRANSITIONS AT PEDESTRIAN STREET CROSSINGS. STRIEET CROSSING SHALL BE PERMITTED TO EQUAL THE STREET OR HIGHWAY GRADE. B. PEDESTRIAN REFUGE ISLANDS (WHERE THE LENGTH OF THE PEDESTRIAN ACCESS ROUTE y <1Q� 1� ��P 13. THE MINIMiUM CLEAR WIDTH FOR PEDESTRIAN ACCESS ROUTES IS 4'-O", EXCLUSIVE OF ACROSS THE REFUGE ISLAND IS GREATER THAN OR EQUAL TO 6 FEET). NATEOF Department of THE CURB., WHEN WALKWAY WIDTHS ARE LESS THAN 54", C. PEDESTRIAN AT-GRADE RAiL CROSSINGS NOT LOCATED WITHIN A STREET OR HIGHWAY. OPPORTUNITY. Transportation 5'-0" x 5"-0" PASSING SPACES (SHOWN IN DETAIL A OR B), OR A FEATURE OF EQUAL OR GREATER DIMENSIONS (E.G., DRIVEWAYS) THAT MEET THE SLOPE CRITERIA, SHALL BE 31. DETECTABLE WARNING SURFACES SHALL BE PROVIDED WHERE THE PEDESTRIAN ACCESS OQ �� PROVIDED AT A MAXIMUM INTERVAL OF 200'. EXISTING DRIVEWAYS AND STREET CROSSING ROUTE CROSSES DRIVEWAYS WITH SIGNAL, YIELD OR STOP CONTROL. DETECTABLE WARNING U.S. CUSTOMARY STANDARD SHEET MAY ALSO SERVE AS PASSING SPACES. SURFACES SHALL NOT BE PROVIDED AT CROSSINGS OF UNCONTROLLED DRIVEWAY APRONS. 14. THE BUFFER ZONE IS A PHYSICAL DISTANCE SEPARATING THE PEDESTRIAN ACCESS 32. SOME DETECTABLE WARNING PRODUCTS REQUIRE A CONCRETE BORDER FOR PROPER ROUTE M THE WHERE THE ZONEE TRAVELED WAY.WIDTH, EXCLUSIVE HOF CURB,R ZONE IS LESSAY BE HAN 3'LONTED THEOR PAVED.SURFACE CURB EDGEOIS TOOLEDQTOEPROVDE THE BARDER SHALL RADIUS, THENOT BORDEREED DMEN'SION 5 E THE BACK OF SIDEWALK AND CURB RAMP DETAILS ALL BE MEASURED SHOULD BE PAVED OR CONSTRUCTED WITH HARDSCAPE MATERIALS. FROM THE INSIDE EDGE OF THE CURB RADIUS. (SHEET I OF 9) PROFESSIONAL ENGINEER NYSDOT TYPE 2 DRIVEWAY ENTRANCE DETAIL 15. THE MAXM(UM RECOMMENDED CROSS SLOPE OF A TURF BUFFER ZONE OR SLOPE 33. THE DETAILS PROVIDED ARE NOT DRAWN TO SCALE. THE QUANTITY OF DOMES DEPICTED NEW YORK LICENSE No. 082537 T TRANSITION]BEHIND SIDEWALK IS 25%. BUFFER ZONES WITH A CROSS SLOPE GREATER THAN ON THE DETECTABLE WARNING UNIT IS FOR ILLUSTRATION ONLY. THE SIZE OF THE 25% SHOULD BE PAVED, PLANTED OR CONSTRUCTED WITH HARDSCAPE MATERIALS. DETECTABLE WARNING FIELD SHALL BE 24" MiNIMUM IN THE DIRECTION OF TRAVEL AND APPROVED MARCH 07. 2016 ISSUED UNDER EB 16-012 UNLESS APPROVED BY ALL AGENCIES HAVING N.T.S. SHALL EXTEND THE FULL WIDTH OF THE CURB RAMP OR FLUSH SURFACE, EXCLUDING ANY 16. WHEN CROSSING DRIVEWAYS, THE WORK SHALL BE IN CONFORMANCE WiTH STANDARD FLARED SIDES. THE WIDTH OF THE DETECTABLE WARNING FIELD INCLUDES A CONCRETE /S/ RICHARD W. LEE,P.E. JURISDICTION, THESE PLANS ARE NOT TO BE UTILIZED SHEET 6OM-03. BORDER, IF PROVIDED. DEPUTY CHIEF ENGINEER 608-01 FOR CONSTRUCTION. OWNER/ CONTRACTOR ARE NYSDOT DRIVEWAY NOTES: 17. FOR PEDESTRIAN SIGNALS AND PEDESTRIAN PUSH BUTTONS, REFER TO STANDARD SHEET 34. ON SLOPES OF 5% OR GREATER, THE ROWS OF DOMES SHALL BE ALIGNED TO BE (DESIGN) RESPONSIBLE FOR CONFIRMING ALL REQUIRED AGENCY 1. "SHOULDER WIDTH" REFERS TO THIE PAVED SHOULDER WIDTH. THE SHOULDER WIDTH MAY BE DESIGNATED AS A PARKING LANE, BIKE LANE, CURB OFFSET, OR OTHER PAVED AREA. 680-10 FOR DETAILS. PERPENDICULAR RADIAL TO THE LOWER GRADE BREAK ON THE RAMP RUN. WHERE DOMES APPROVALS HAVE BEEN SECURED PRIORTO ARE ARRAYED RADDIALLY THEY MAY DIFFER IN DOME DIAMETER AND CENTER-TO-CENTER COMMENCEMENT OF WORK, WHETHER DESCRIBED ON 18. WHERE EXIISTING ROADWAYS ARE SAWCUT TO INSTALL CURBING AND/OR SIDEWALK, THE SPACING WITHIN THE RANGES SPECIFIED N SHEET 2. ON SLOPES LESS THAN 5%, DOME THESE PLANS OR OTHERWISE. 2. A DRIVEWAY TIP-UP SECTION SHOIULD EXTEND TO A LOGICAL TERMINI (EXAMPLE: SIDEWALK EDGE, WHERE THE DRIVEWAY GRADE MATCHES EXISTING GROUND, OR LAYOUT POINT). FOR REFERENCE, ROADWAY SHOULD BE SAWCUT AT LEAST 24" FROM THE PROPOSED CURB LINE TO ALLOW ORIENTATION IS LESS CRITICAL AND MAY DIFFER FROM PERPENDICULAR OR RADIAL A REASONABLE LENGTH FOR TAPERING THE TIP-UP SECTION BACK TO THE EDGE OF DRIVEWAY IS 3-4 TIMES THE LENGTH OF CURB DROP. THE TIP-UP SECTION IS NOT PART OF THE CURBALINEE,ATE THENO THE CROADWAY FOR ASPHALT BEi REBUILTTUSiNGESS CLASSAC CONCRETE.SEEOPOSED ALIGNMENT TO THE GRADE BREAK. REVISIONS DRIVEWAY OPENING WIDTH. REFER; TO NYSDOT STANDARD SHEET TITLED "MISCELLANEOUS CURB DETAILS" FOR THE CURB TRANSITION. DETAILS ON SHEET 9 OF 9. 35. THE DETECTABLE WARNING FIELD SHALL BE THE COLOR SPECIFIED IN THE CONTRACT DOCUMENTS OR MEET THE REQUIREMENTS OF THE STANDARD SPECIFICATIONS. DETECTABLE REV NO. DATE REVISION 3. FOR DRIVEWAYS WITH A DRIVEWAY OFFSET LESS THAN 16', THE TAPER METHOD IS NOT GENERALLY RECOMMENDED, UNLESS IT CAN BE FIELD VERIFIED THAT THE DRIVEWAY ENTRANCE WIDTH WILL WARNING SURFACES SHALL CONTRAST VISUALLY ADJACENT GUTTER, STREET OR HIGHWAY, OR PEDESTRIAN ACCESS ROUTE SURFACE, EITHER LIGHT-ON-DARK OR ACCOMMODATE THE VEHICLES THAT USE THE DRIVEWAY ON A REGULAR BASIS. DARK-ON-LIGHT. 1 1012412J WSC. REVS 4. IF THERE ARE CONSTRAINTS THAT PREVENT THE CONSTRUCTION OF THE DRIVEWAY OPENING AS PER EITHER OF THE LAYOUT METHODS, THE ENGINEER MAY SPECIFY A SMALL CORNER CURB (� �T SIDEWALK �( /�g� 2 5123/24 PER TOWN COMMENTS' RADIUS OF :2' (OR "1/2 BULLNOSIE" CURB ALONG LOW SPEED HIGHWAYS), PROVIDED THE DRIVEWAY OPENING MEETS THE WIDTH ON STANDARD SHEET "DRIVEWAY OPENING LIMITS". NYSDOT ° ®1 " C�E T E S I D E ALK CURB `AMP i� NOTES 5. THE MINIMUM PAVING LIMIT SHALL EXTEND TO THE RIGHT-OF-WAY LINE OR 2' BEHIND ANY SIDEWALK, IF PRESENT, OR 10 FEET FROM THE OUTSIDE EDGE OF TRAVEL LANE, WHICHEVER IS N.T.S. 3 7/23/26 REV SITE LAYOUT GREATER. THE PAVING LIMIT MAY EXTEND BEYOND THE MINIMUM PAVING LIMIT FOR NEW DRIVEWAYS AND TO TRANSITION TO EXISTING PAVED DRIVEWAYS. 6. ANY SIDEWALK WHICH CROSSES A DRIVEWAY SHALL HAVE A MINIMUM THICKNESS OF 6" AND INCLUDE WIRE FABRIC REINFORCEMENT WITH 3" OF TOP COVER. 7. TO PREVENT DRIVEWAY GRADES FROM EXCEEDING THE 6% MAXIMUM SLOPE, IT MAY BE NECESSARY TO DEPRESS THE SIDEWALK ACROSS THE DRIVEWAY. SIDEWALK RAMPS SHALL HAVE THE R LEAST SLOP17 POSSIBLE, NOT TO EXCEED A LONGITUDINAL SLOPE OF 1:12 OR A DESIGN CROSS SLOPE OF 1.5%. WHERE THE HIGHWAY GRADE MAKES A 1:12 SLOPE IMPRACTICAL, THE RAMP LENGTH MAY BE RESTRICTED TO V 5'. 8. WHERE THERE ARE CONSTRAINTS TFHAT PREVENT CONSTRUCTION OF THE DRIVEWAY OPENING USING EITHER OF THE LAYOUT METHODS, THE ENGINEER MAY SPECIFY A SMALL CORNER CURB RADIUS PAVING LIMITS o OF 2' (OR A "1/2 BULL NOSE" CURB ALONG LOW SPEED HIGHWAYS), PROVIDED THE DRIVEWAY OPENING MEETS THE REQUIREMENTS OF THE "DRIVEWAY OPENING" TABLES ON SHEET 4 OF IBM _ NYSDOT STANDARD SHEET 608-01. (SEE DRIVEWAY NOTE 9) 9. FOR RESIDENTIAL DRIVEWAYS, THE MINIMUM DRIVEWAY PAVING LIMIT SHALL BE 10' FROM THE OUTSIDE EDGE OF TRAVEL LANE OR 2' BEHIND ANY SIDEWALK, IF PRESENT, WHICHEVER IS GREATER. CURB Sc GUTTER p%t eO000 o �� FOR MINOR COMMERCIAL DRIVEWAY'S. THE MINIMUM PAVING LIMIT SHALL BE 30' FROM THE OUTSIDE EDGE OF TRAVEL LANE, OR 2' BEHIND ANY SIDEWALK, IF PRESENT, OR EXTEND TO THE RIGHT-OF-WAY LINE, WHICHEVER VS GREATER. THE PAVING LIMIT MAY EXTEND BEYOND THE MINIMUM PAVING LIMIT FOR NEW DRIVEWAYS AND TO TRANSITION TO EXISTING PAVED DRIVEWAYS. PROP. BUFFER (SEE DRIVEWAY NOTE 10) °o+eo a Gee. 10. o o i e°eo a°e ee esee a se°ee 10. EXISTING ASPHALT BUFFER TO BE REPLACED AS REQUIRED IN ACCORDANCE WITH NYSDOT ITEM #610.1601 - TURF ESTABLISHMENT-ROADSIDE. TRAVEL LANE SIDEWALK eoe o se PROP. 5' WIDE EXISTING 11. ANY PORTLAND CEMENT CONCRETE: SIDEWALK WHICH CROSSES A DRIVEWAY SHALL HAVE A MINIMUM THICKNESS OF 6" AND INCLUDE STEEL MESH REINFORCEMENT WITH 3" OF TOP COVER. 5 -O MIN. CONCRETE SIDEWALK FINISHED DROP CURB 12. WHERE DRAINAGE IS CARRIED ALOiNG THE CURB, CONSTRUCT THE DRIVEWAY WITH A SHORT UPGRADE TO PREVENT RUNOFF FROM PONDING AT THE DRIVEWAY ENTRANCE (FLAT DRIVEWAY) OR PROP. ON-SITE GRADE GRADE BREAK AT BOTTOM OF RAMP 0` _ �' gS• RUNNING DOWN THE DRIVEWAY (DOWNHILL DRIVEWAY SLOPE). IF CONDITIONS MAKE THE ADDITION OF A SHORT UPGRADE IMPRACTICAL, USE 1" CURB REVEAL AND CONTINUE CURB ACROSS THE VARIES ASPHALT PAVEMENT ONE CORNER OF DETECTABLE DRIVEWAY OPENING. --"b.- 1.57 MAX. THE EDUCATION LAW OF THE STATE OF NEW YORK PROHIBITS ANY 8.0/. MAX. �_ WARNING SURFACE LOCATED PERSON ALTERING ANYTHING ON THESE DRAWINGS AND/OR THE AT BACK OF CURB (TYP.) ACCOMPANYING SPECIFICATIONS, UNLESS IT IS UNDER THE (P I O N DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. WHERE SUCH ALTERATIONS ARE MADE, THE PROFESSIONAL ENGINEER MUST SIGN AND SEAL, DATE AND DESCRIBE THE FULL EXTENT OF THE ALTERATION ON THE DRAWING AND/OR IN THE SPECIFICATIONS. PROP. DRIVEWAY (SLOPE GRADE BREAK TO BACK OF CURB do (NYS EDUCATION LAW SECTION 7209-2) VARIES, 6.0% MAX.) LESS THAN 5'-0" DROP CURB 1" REVElAL TO i•= a Al u 24 MIN. IN DIRECTION OF TRAVEL ,, ,., 0 0 BE REPLACED IN KIND DRIVEWAY PROFILE FOR CURBED SECTION (SEE NOTE 4) a a l. (SEE DRIVEWAY NOTE 12) WITH SIDEWALK IN CUT SECTION 0 , :, & , ::. :, �S, 0 ,.. A 0, CURB (TYP.) Q �I � 19G v •,_ Y 0 r TYPICAL NYSDOT DRIVEWAY PROFILE DETAIL `� N, d �: s, d, � sr t m DODO DODO NOV 1 6 2026 DETECTABLE NARhIkG NOTES: � � °° ¢ °O'O°.°°° BUFFER ZONE e° a Qpmo° 440 a s' o a, 0 :, ° o o°o°eo ° N.T.S. 1.DETECTABLE WARMING SURFACES PWSI SHALL BE FROVIDED AT THE FOLLLOONC LOCATI04S ON PEDESTRIAN ACCESS ROUTES: ASPHALT UTILITY STRIP c c c c o ;° ooQo °e°e°oe°eO°°e° SOUTHOLD TO4Vdhl ( ) e o 0 0 o ea e ° RAMP SLOPE , „ PI-AIVIIING BOARD A, CURB RAMPS AND BLENDED TRANSITIONS AT FEDESTRIAN STREET CROSSINGS, d .a 0, 00 008000000 000000000 B. PEDESTRIAN REFUGE ]SLATS (WHERE THE. LENGTH OF THE PEDESTRIAN ACCESS ROUTE ACROSS THE REFUGE ISLAND IS GREATER THAN OR EQUAL TO 67. RAMP C 0a0°eoo°ee o00000000 OPTIONAL LEVEL SECTIONS DODO 0009 C. PEDESTRIAN AT-GRADE RAIL CROSSINGS NOT LOCATED WITHIN A STREIET OR HIGHWAY, �Ss` L o0oe0°00°O 2.DETECTABLE WARNING SURFACES SHALL BE PR)VIDED WHERE THE PESESIiRIAN ACCESS ROUTE CROSSES DRIVEWAYS WITH SIGNAL, YIELD OR STOP CONTROL. �l� N MMIN. SLOPE AX SLOPE s20 DROP CURB DETECTABLE WA.R14ING SURFACES SHALL :NOT BE PROVIDED AT CROSSINGS; OF UNCONTROLLED .DRIVEWAYS. SITE ADDRESS: 3.WITH THE EXCEPTION OF THE "DETECTABLE VIANING SURFACE TRUNCATED DOME DETAILS" DETECTABLE WARNING DOMES ON THIS SHEET ARE NOT DEPICTED TO JOINTS AS GRADE BREAK AT BOTTOM OF RAMP DETECTABLE WARNING SURFACE LOCATED SCALE. REQUIRED ABOVE LOWER GRADE BREAK PROPOSED CONVENIENCE STORE 4.DETECTABLE WARNING FIELDS SHALL EXTEND 24" MiINIWJMi IN THE DIRECTION OF PEOTRIAN TRAVEL ACROSS THE FUEL WIDTH Or THE CURB RAMS OR FLUSH NYSDOT CONCRETE CURB RAMP DETAIL �TYPE I `-_ - - __ ~~`~+• '� (SEE NOTES 5B AND 6) WITH FILLING STATION SURFACE, EXCLUDING ANY FLARED SIDES. -`' - (OPTION T I O N 2 5.SOLE DETECTABLE WARNING PRODUCTS REQUIRE A CONCRETE BORDER FOR PROPER INSTALLATION. BORDERS CANNOT BE INCLUDED AS PART OF THE 24" MIN" CONFIGURATION W/ RAMP SIDE OPTION C: �'_R_ '-_ -�- _______- � � 7400 MAIN ROAD DIMENSION DESCRIBED IN NOTE 4. CURB RETURNS MPTIONAL) NYSDOT DETECTABLE WARNING PLACEMENT DETAILS MATTITUCK, A. WHEN PLACED AT THE BACK OF CURB, DETECTABLE WARNING FIELDS SHOULD BE PLACED AS CLOSE TO THE BACK OF CURB AS PRACTICABLE. BOTH FRONT OPTIONAL) OPTIONAL I„ N.T.S. TOWN OF SOUTHOLD CORNERS OF THE DETECTABLE WARNING FIELD SHALL NOT BE LOCATED MORE THAN 2 FROM THE BACK OF CURB. rHERE THE BACK OF THE CURB EDGE IS N.T.S. TOOLED TO PROVIDE A RADIUS, THE BORDEF: DIMENSION SHALL BE MiE(ASURED FROM THE INSIDE EDGE OF THE CURB RADIUS. WHERE CURB IS NOT USED, THE CURB REVEAL A SUFFOLK COUNTY, NY 11952 EDGE OF PAVEMENT SHALL BE SUBSTITUTED FOR THE BACK OF CURB FOR PLACEMENT OF DETECTABLE WARNINGS. (SEE NOTE 1) EDGE OF PAVEMENT B. WHEN PLACED MOVE THE LOWER GRADE BREAK OF A CURB RAM[', DETECTABLE WARNING UNITS SHOULD BE PLACED AS CLOSE TO THE JOINT• AS PRACTICABLE. SIDE FLARE (TYP.) OF CURB e E DISTRICT: 1000 BLOCK: 07 BOTH FRONT CORERS OF RECTILINEAR DETECTABLE WARNING FIELDS SHALL NOT BE LOCATED MORE THAN 2" FROM THE JOINT. (SEE NOTE 23) SECTION: 122 LOTS: 1 & 3.2 C. WHEN RADIAL DWS UNITS ARE PLACED AT THE BACK OF CURB, THE MONT EDGE OF THE DWS FIELD SHOULO BE AS CLOSE AS POSSIBLE TO THE BACK OF CURB, LE, THE RADIUS OF THE FRONT OF THE DWS FIELD SHOULO MATCH THE RADIUS ALONG THE BACK OF CURB AS CLOSELY AS POSSIBLE. THE OUTSIDE ��'�'�_� _ 25% MAX. AT CURB LINE SCAL : AS SHOWN HPE# EMP021-01 CORNERS OF THE DWS FIELD MUST BE LOCATED NO MORE THAN 2 INCHES FROM THE BACK OF CURB. ���. -''' (BOTH SIDES) � � � + TRUNCATED DOME DIMENSIONS �,a�. 6 a��-m`-d-r T� PICAL NYSDOT CAST-IN-PLACE Dom. 6.ON SLOPES OF 5X OR GREATER, THE ROWS OF DOMES SHALL BE ALIGNED) TO BE PERPENDICULAR OR RADIAL TO THE LOWER GRADE BREAK ON THE RAMP RUN. 'I. DIM. MIN. (IN) MAX. QNI 10/9/23 DWG # EMP021-01-SP.3° WHERE DOMES ARE ARRAYED RADIALLY, THEY MAY DIFFER IN DIAMETER AND CENTER-TO-CENTER SPACING WIT IN THE RANGES SPECIFIED ON THIS SHEET. DOME �'''r - R e CONCRETE CURB TRANSITION DETAIL A B A l.fi" 2.4" DRAWN BY. LD CHECKED BY. CT ALIGNMENT THAT IS PERPENDICULAR OR RADIAL TO THE LOWER GRADE BiREAK IS NOT REQUIRED ON SLOPES OF LESS THAN 5K -� - -� T.THE DETECTABLE WARNING FIELD SHALL BE THE COLOR SPECIFIED IN THE CONTRACT DOCL ENTS OR MEET THE REQUIREMENTS OF THE STANDARD _ a -� �Sy _ _ a NTS B 0.65" 1.5" Ua SPECIFICATIONS. DETECTABLE WARNING SURFACES CONTRAST VISUALLY WIDTH ADJACENT GUTTER, STREET OR HIGHWAY, OR PEDESTRIAN ACCESS ROUTE SURFACE, . ,s m w►fq �� NOTE: TERMINATE CURB, CURB AND GUTTER BY TRANSITIONING + + + C 50% - 65% OF D DIM. -ON EITHER LIGHT-ON-DARK OR DARK -LIGHT. _ ON A MAXIMUM SLOPE OF 1:12 TO PAVEMENT SURFACE. fl 0.9" 1.4" DETAIL SnEET BUFFER ZONE _ - - -- �s-; (GRASS UTILITY STRIP) �_ .° � .'=^;a"g=.- CMB TRANSITION LENGTHS 11 E PLAN III - Cq RAMP INI/t H LOPE Ise b12 1:20 „ (NYSDOT) r 1�u r +} �-is 0'2 4 48 80r 6" 24N i'2" 121YI SHEET NO• NYSDOT CONCRETE CURB RAMP DETAIL TYPE I SECTION E D O CONFIGURATION W RAMP SIDE OPTION A: NYSDOT DETECTABLE WARNING 0 CURB RETURNS SURFACE TRUNCATED DOME DETAIL N.T.S. N.T.S. REV. 3 OF 10 Nr APPROVED 24" HEAVY DUTY PROP. SEPTIC TANK (S-6) HIGH CAST IRON FRAME & WATER I W/ TRAFFIC RATED COVERS :, TIGHT, INSECT PROOF, I I PROP. LEACHING POOL (S-8) PROP. LEACHING POOL (S-9) ' 7w ADJUSTABLE AND LOCKING 1 CONVENIENCE 8x 4 ' LIQ. DEPTH W/ TRAFFIC RATED COVER W/ TRAFFIC RATED COVER POINT APPROVED 24" HEAVY DUTY CAST IRON COVER TO GRADE ! STORE W/2ND RIM IN = 20.40 PROP. DISTRIBUTION FRAME & WATER TIGHT, INSECT PROOF, TIMBRE)GRADE FLOOR OFFICE RIM OUT = 20.26 MANHOLE (S-7) W/ 10'0x 6 EFF. DEPTH 1 Cox 6 EFF. DEPTH em ADJUSTABLE AND LOCKING COVER TO GRADE - TRAFFIC RATED COVER 4' CAST BLOCK OR I (NO BASEMENT) INV. IN = 17.40 RIM = 20.13 RIM = 20.46 RIM = 19.95 ENGINEERING OPENING MUST BE OVER PRECAST CONC. COLLAR TO 8" CONC. TOP TO 1 BRING MANHOLE TO GRADE 1 I INV. OUT = 16.90 OUTLET DROP TEE SUPPORT H-20 VEHICULAR COYIDMAN1fOLE INV. IN = 16.78 INV. = 16.60 INV. = 16.60 FlN►SHED GRADE I I FLOOR SLAB PROPOSED TOP OF RINGS REFERS N LOADING 4000 PSI ® 28 I TOP RING = 17.90 (KITCHEN) TOP RING = 18.60 TOP RING = 18.60 PREXT RISER TO THIS POINT (SEE GAYS (EL.2ENT) CLEANOUT SANITARY SYSTEM (NO BASEMENT) TO GRADE BOT. RING = 12.90 INV. OUT = 16.68 ROT. RING = 10.60 BOT. RING = 10.60 1860 WALT WHITMAN ROAD PROFILE) ❑ ❑ ❑ ❑ ❑ ❑ FINISHED GRADE SUITE 600 TOP OF RINGS " " in �--� REFERS TO THIS 2'-0 - 2-0 w INLET PIPE (REFER TO ❑ ❑ ❑ ❑ ❑ AD1MAMX1DCXM0TM*F• MELVILLE,NY 11747 POINT SEE PROFILE FOR EFSIZE) ❑ ❑ ❑ ❑ ❑ CAST 13LON FRAME ae AN CDVEt ► (516)777-4320 FAX: (516)777-4321 SANITARY SYSTEM 20" •• ':' 20 PITCHED 1/8"/Fr MIN. ❑ ❑ ❑ ❑ ❑ PROFILE) _ "'•,. 8"TRAFFIC BEARING • •' SLAB-H20 LOAD RATED ❑ ❑ ❑ ❑ ❑ 2.rMAX -�- ❑ ❑ ❑ ❑ ❑ 0 VIRGIN ra'A"• -B"tit.t�t'.t IGsr�nn�o ALL PHASES OF ENGINEERING DESIGN, Z v ` ❑ ❑ ❑ ❑ ❑ �� CAST IRON PIPE TO - _� -1 TO MEHTAASFrMMO _ _ _ _ _ _ _ _ _ _ _ _ SURVEYING,CODE CONSULTING, ` ❑ ❑ ❑ ❑ ❑ ED EXTEND MIN.2'THRUFOUNDATION WALL 5 LF 6"0 PVC ZONING ANALYSIS&BID SPECIFICATION INLET FROM KITCHEN .,y: tO FLOW UNE -� ❑ ❑ ❑ ❑ ❑ c STEPS ARE TOWCOWL> (SDR-35) 6" DIA SDR-35 PVC .; % / ❑ ❑ ❑ ❑ ❑ Tn \/\ POLYPROPYLENRCOATEDIf2• PROP.KITCHEN 1/4"/FT MIN. PIPE PITCHED MIN. OUTLET 6" DIA ❑ ❑ ❑ ❑ ❑ a ETE62 gtroc s•tvetL INVERTS-1) SLOPE WWW.HPEng.com 1/4"/FT . :� PITCHED MIN. / \ INV.=19.00 (KITCHEN) •..• 1/4"/FT VIRGIN JODFr�+itrl,NrlosE SOIL / ❑ ❑ ❑ ❑ ❑ `/ t•EUTYLMMMMIRDR 12 LF 6"03 PVC(SDR-35) 8 LF 6"0 PVC t° o � \ ❑ ❑ ❑ ❑ \�\�. Au rouars 5 LF 6"0 PVC(SDR-35) PROP. GREASE TRAP (S-3) @ 1/8'/FT MIN.SLOPE (SDR-35)� CHRIS M. TARTAGLIA \/\ ❑ ❑ ❑ ❑ b / ol PR0VWEN0X49W1iKM @1/4"/FT MIN.SLOPE W/ TRAFFIC RATED COVERS (KITCHEN) 1/8"/FT MIN. r 1QA4[JOWTSEALANT. (KITCHEN) SLOPE ^01 I EVV y BOTTOM OF RINGS t� •• %\ ❑ ❑ ❑ ❑ \/ COM[RLtlEDtVFJiTFOR►D+D1o' 6"(C7 PVC(SDR-35) COMBINED REFERS TO THIS ❑ ❑ ❑ ❑ / / INV.=17.18 Q. MAf�h- \ \ ATLEk9rTFWJM-QUARTBd 8'x 5 ' LIQ. DEPTH ( ) POINT (SEE w / \ OFTBCDIAMtitEIIOFTAEP 1 CASTINPLACy8W11H FROM SANITARY CAsrn+ru`cePrexB RIM IN = 20.70 ;• f a• STAUCMS STMSTRAPS SYSTEM) Q OFFILE) SYSTEM in \ ❑ ❑ ❑ ❑ \\ \� •I- os RIM OUT = 20.60 Q � ❑ ❑ ❑ ❑ /\ . �-----4a">D.-- -� P-MaRERuss�Boor. INV. IN = 18.20 .- BOTTOM OF RINGS REFERS ❑ ❑ ❑ ❑ � INV. OUT = 17.70 r" *: •. ' p, ,a . : TO THIS POINT (SEE ❑ ❑ ❑ ❑ TOP RING = 18.70 '*• y•'' :e SANITARY SYSTEM PROFILE) I.ALL MANHOT.I3 SECTIONS SHALL CONFORM TO A.S.T.M.C-478,LATEST REVISION ❑ ❑ ❑ 1 RE❑ STANDARD SPECIFICATIONS FOR PRECAST REINFORCED CONCRETE M.I.SECTIONS;. BOT. RING = 12.70 KITCHEN SYSTEM PROFILE p 7820g 8'0 I. -==-0,0 3'-0" 2.MANHOLE RISER SECTION TO BE FURNISHED IN 1,2,3,OR 4'HEIGHTS.AS UMED.. o MIN. 3.LOADING TO CONFORM TO AASEITO H-20 LOADING. Qom° STRUCTURE SHALL 13E MONOLITHIC POUR AND) PRECAST CONCRETE. GMDWA S "' 4.ALL CONCRETE IS TO MEET 4000 PSI AT 28 DAY SET. PR ` NGI N E E R 5.TYPICAL GREASE TRAP DETAIL -� 6.THE AA��SUM BE SET CHANGEIN�NHS•WEIINMHrANDOUT MPNERT(S) NEW YORK LICENSE No. 078209 BACKFlLL MATERIAL SHALL BE PROP. PRE-TREATMENT TANK NTS CLEAN SAND AND GRAVEL SIIALL BE NO GREATER TFIAN 2 FEET. (S-4) W/ TRAFFIC RATED PROP. HYDROACTION AN500-C LAWRENCE D. 0 BRIEN COVERS (S-5) W/ TRAFFIC RATED SANITARY LEACHING POOL DETAIL SANITARY JUNCTION 4'-1" x 5.17 ' LIQ. DEPTH COVERS RIM IN = 2080 PROP. LEACHING POOL (S-8) PROP. LEACHING POOL (S-9) SCALE = NTS MANHOLE DETAIL CONVENIENCE RIM IN = 21.20 RIM OUT = 27.5E W/ TRAFFIC RATED COVER W/ TRAFFIC RATED COVER STORE W/2ND RIM OUT = 20.95 SCALE: N.T.S. INV. IN = 17.90 PROP. DISTRIBUTION FLOOR OFFICE INV. IN = 18.60 MANHOLE (S-7) W/ 1 O'Ox 6 EFF. DEPTH 1 O'Ox 6 EFF. DEPTH (NO BASEMENT) INV. OUT = 18.35 INV. OUT = 17.82 TRAFFIC RATED COVER RIM = 20.46 RIM = 19.95 TOP OF = RIM = 20.13 TOP RING = 19.35 18.57 INV. = 16.60 INV. = 16.60 FLOOR SLAB PROPOSED STRUCTURE INV. IN = 16.78 ROT. RING = 13.18 TOP RING = 18.60 TOP RING = 18.60 (EL.22.00) CLEANOUT BOT. OF = 12 57 (SEPTIC) (NO BASEMENT) TO GRADE STRUCTURE INV. OUT = 16.68 BOT. RING = 10.60 ROT. RING = 10.60 FINISHED GRADE PROFESSIONAL ENGINEER NEW YORK LICENSE No. 082537 UNLESS APPROVED BY ALL AGENCIES HAVING JURISDICTION, THESE PLANS ARE NOT TO BE UTILIZED FOR CONSTRUCTION. OWNER/ CONTRACTOR ARE 41-9" SPECIFICATIONS CAST IRON PIPE TO -- - - - - - - - - - - - RESPONSIBLE FOR CONFIRMING ALL REQUIRED AGENCY EXTEND MIN. - - - - - - - - - - - APPROVALS HAVE BEEN SECURED PRIOR TO 1 Design in Accordance With ASTP�t C478 (SDR-35)@ FOUNDATIONN WALL ALL s LF 3 PVC COMMENCEMENT OF WORK, WHETHER DESCRIBED ON _ THESE PLANS OR OTHERWISE. 4'-1" 4' 91/d' 1 51/4' 1/87FT MIN. For AASHTO NS-20 Loading. PROP. 5 LF 4"0 PVC(SDR-35) SLOPE 6"P3 PVC(SDR-35) SANITARY @ 1/4'YFT MIN.SLOPE REVISIONS 2. Earth Load=C- 2.5ft (SANITARY) INV.=20.05 --=� INVERT(S-2) (SANITARY) SYSTEM) REV NO. DATE REVS/ON -.. .� (FROM KITCHEN =�---=---=--. Welded Wire Mesh3. Concrete 4000psi @28 Days INV.=19.00 As=0.12 sq-inAf Typ. 4. Rebar-ASTM A-615 Grade 60 Welded Wire Mesh AST`M A-1064 SEPTIC SYSTEM PROFILE 8 LF 6"fd PVC 1 10/24/23 MISC. REVS Inlet '1`r �; �t +'.✓I '�, I 5. Concrete Cover 11/4 UNO (SDR-3MIN.SLOPE 2 5123/24 PER TOWN COMMENTS MIN.SLOPE 6. Storage Capacity 97.96 Gallons per ft (COMBINED) 3 7/23/26 REV SITE LAYOUT 7_Additional Reinforcing Around Openings Outlet ' Equal to the Bars Interrupted, Half Each Side 8. Openings Trimmed with Diagonal#4 Bars SANITARY PROFILES Welded Wire Mesh Extended Min 12" Beyond Openings Bent N.T.S. - - •--' To Maintain Bar Cover As =0.12 sq-inllf Tig+p. - (2)#4@3in ES Opgs (Center 113 In Wall)) 9. Ground Water Table At Finished Grade. TOP SLAB 10. Buoyancy Safety Factor= 1.50 PLAN #4@ 7in Max Sp Note- 10" Diameter Campbell 24 Diameter Campbell Pattern 1007 SANITARY' Precast Manufacturer will be " Pattern 4165 Or p APPROVED 24 HEAVY DUTY 1 Identified by an Imprinted CAST Approved Equal for Or Approved Equal TIGGHT,IRINSECTRO F ON FRAME &WATER 1 I Labe!On the Interior Wall of ADJUSTABLE AND LOCKING 9"sO Access Opening Brick Adjustment& Casting the Tank COVER TO GRADE To Grade,2'-0" Maximum FINISHED GRADE r Flat Joint Inlet L :7 LiE Uid Level - 4"Outlet(Mm-) -" PRECAST RISER AS REQUIRED " THE EDUCATION LAW OF THE STATE OF NEW YORK PROHIBITS ANY �i 2-0 2-0 zo N PERSON ALTERING ANYTHING ON THESE DRAWINGS AND/OR THE \`-Rubber Connector(Typ.) TOP OF RINGS ACCOMPANYING SPECIFICATIONS, UNLESS IT IS UNDER THE -- Butyl Gasket Seal(2)Rows • // �� REFERS TO THIS DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. WHERE SUCH X �� POINT (SEE +, 2'-D" •• a 2'_0" ALTERATIONS ARE MADE, THE PROFESSIONAL ENGINEER MUST SIGN .•• .`'' -8*TRAFFIC RETIRING SLAB- AND SEAL, DATE AND DESCRIBE THE FULL EXTENT OF THE ( SANITARY SYSTEM ALTERATION ON THE DRAWING AND/OR IN THE SPECIFICATIONS. 4'-9" InWt outlet H2O LOAD RATED / Tee Eaf le Conforming to �- 6 -4" PROFILE) •' (INYS EDUCATION LAW SECTION 7209-2) 9 �" � NSF Standard 46,Extend 11 z zo JOINT DETAIL 16'Below Liquid Level ��\ -i..- Welded Wire Mesh ��r INLET MIN. 6" DIA. tO tO ROW LINE -� TO LEACHING POOL As=0.12 sq-iNlf Typ_ SDR-35 PVC PIPE " a ----� (Center 1l3InWall) (TYP.) PITCHED MIN. .•. ' OUTLET 6" DIA. PITCHED 1/4"/FT R • '•.• MIN. 1/8"/FT oo . ' W #4 c D6in EW-i `-- #4 Dowels x42"Lg Advanced Waster water Solutions o 0 0 WEIGHTS: w>- PLC CONTROL PANEL • 3 BASE UNIT:12,250 LBS. NTH AIR PUMP. p NOV 16 2OL'-' �/^�'+ � � 1$"O.G.Radially � � oo � SECTION ROOF SLAB:4,100LB. _ 'SfWTI 7'T0�'JI!' f i'# MAY BE MOUNTED ON UNIT HS-20 LOAD RATED BOLTED U Product: .r300 Gallon Pre-Treatment Tank OR REMOTELY. CAST IRON COVER. BOTTOM OF RINGS 4 r�Lf.t"'I'rl';BOAPD MAXIMUM OF 3'OF EXTENSION UJ _..I REFERS TO THIS L..- w �� - p ' �` •" I am. COLLARS MAY BE USED TO N Prof data dbydAg_ POINT (SANITARY SYSTEM • •• 1'9" BRING CASTING TO GRADE. �•. SC!DHS Approvai for Usce Pace 2 cf 12 23-0721 8,115,123 VCE PT-500 BUTYL RUBBER GASKET PROFILE) r b io> RUBBER PIPE CONNECTOR I/A OWTS PRETREATMENT TANK DETAIL 8'0 SITEADORESS Inllet FL LINE 3 Outlet N.T.S. STRUCTURE SHALL BE MONOLITHIC POUR AND PRECAST CONCRETE. PROPOSED CONVENIENCE STORE WITH FILLING STATION 7'-8" TYPICAL SEPTIC TANK DETAIL 7400 MAIN ROAD 7'-4 SCALE = NTS MATTITUCK, 5'-4" 5'-3" TOWN OF SOUTHOLD FINISHED GRADE CAPPED OR PLIUGGED TO GRADE NCOMING SERVICE S 200A, 3/0, 480/277 VOLTS UFFOLK COUNTY, NY 11952 NEW 20 AMP, 1 POLE BREAKER S C D H S APPROVAL DISTRICT: 1000 BLOCK: 07 SECTION: 122 LOTS: 1 & 3.2 -III-I I I I-III- 120 VOLT, 1/0 SERVICE TO UTILITY SCALE' AS SHOWN yPE EMP021-01 CONTROL PANEL GIRD IN ' " PRECAST CONCRETE PATE' 10/9/23 DWG ' EMP021-01-SP.3a PVC CONDUIT I 8 J MONOLITHIC TANK HS-20 LOAD RATED SEE p 10'-9" EARTH COVER:0.50-3.0 FT. DRA WN B LD CHECKED BY.• CT PROFILES CIRCUIT BREAKER 4"0/6"0 45' BEND FUJI PANEL METER IIYDROACTION AN500 - C (DR18/SDR35) CONTROL .NITROGEN REDUCTION SYSTEM PANEL DETAIL L SHEET N.T.S. (4"x4"x4") OR 6"x6"x6" WYE BRANCH 1 V �N01 FABRICATED WYE) NOTE: _ GROUND ROD (SANITARY) FLOW 4"0/6"0 MIN. DIA. 4"0/6"0 MIN. DIA. FLLO _ 1) BURIED ELECTRICAL POWER CONDUITS SHALL BE A -� (DR-18/SDR35) (DR-18/SDR35) MINIMUM OF 24 INCHES BELOW GRADE. SHEET NO• TYPICAL SANITARY / KITCHEN 2) ALL ELECTRICAL WORK TO BE PERFORMED IN D ACCORDANCE WITH NEC. L HOUSE C EANOUT DETAIL SINGLE-LINE DIAGRAM 0 N.T.S. N.T.S. REV. 3 OF 10 HIGH 61 Q POINT ENGINEERING 58'-4" 57'-8" 1860 WALT WHITMAN ROAD SUITE 600 5s'-4" MELVILLE,NY 11747 47'-2 7/8" X-108'-1 1/4" (516) 777-4320 FAX: (516) 777-4321 ALL PHASES OF ENGINEERING DESIGN, SURVEYING, CODE CONSULTING, ZONING ANALYSIS &BID SPECIFICATION MECHANICAL CU-1 CU-2 CU-3 www.HPEng.com EQIPMENT PAD WALK-IN COOLER I WALK-IN COOLER' WALK-IN FREEZER T 001 �' �' �' CHRIS M. TARTAGLIA W L�i_c f A/C-2) f A/C-3 I A/C-4 '` A-F� ELECTRIC SERVICE, w Nu+Rp r �P �— - METER, MDP AND MTS —� •4- -+ I I I I I FI I I I I I I r e��I r- — 1I I I I I � � MTS MDP 000 % o�a2o � ss� PROFESSI NGINEER NEW YORK LICENSE No. 078209 ELECTRIC PANELS - - - - - - I ( Mt- � BACKROOM/ I I 00 LAWRENCE D. 0 BRIEN co — I ( I `D UTILITY OFFICE' I 00 `�' I i "' 103 ( I I I 105 DESK I �' I ( N co �/ GAS I 8-0 AL" 7 I I METER INCOMING WATER Z o / SERVICE O I " /I/ �/ // ADA /4 I PROFESSIONAL ENGINEER NEW YORK LICENSE No. 082537 I — — — — � I•---�I "��RESTROOM J 8'-1 1/4" ® /I 104 // / //�/ 22'-8" I UNLESS APPROVED BY ALL AGENCIES HAVING JURISDICTION, — — //I� '/ X I ' / -/ //C I' // �/ I THESE PLANS ARE NOT TO BE UTILIZED FOR CONSTRUCTION. L_ �1/ o I OWNER/ CONTRACTOR ARE RESPONSIBLE FOR CONFIRMING ° / / ALL REQUIRED AGENCY APPROVALS HAVE BEEN SECURED I /'�/�/ 711� //j//. WALK-IN I PRIOR TO COMMENCEMENT OF WORK, WHETHER DESCRIBED ON THESE PLANS OR OTHERWISE. COOLER �� '® Preal / (12 30" COOLER DOORS REV NO. DATE REVISION ' I N / //// // / (1) 36" LOADING DOOR FOOD BEVERAGE / / / 1 5 23 2024 Per Town Comments NI - - _ _ _ //j/ COUNTERS C� 34" 2 111212026 Misc. Coordination N I I �'\ e00 e /co / ere. / / 5'-4"// /8 GONDOLAS , `o STAIRWELL /f / NDOU-T 36W/ GOND�736W f3bND�736W ; Al /// COFFEE 4COUNTER o /j///j///// ///j////////// i THE EDUCATION LAW OF THE STATE OF NEW YORK / / / / PROHIBITS ANY PERSON ALTERING ANYTHING ON THESE I DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATIONS, / / / I UNLESS IT IS UNDER THE DIRECTION OF A LICENSED A GONDOLAS \// I PROFESSIONAL ENGINEER. WHERE SUCH ALTERATIONS ARE /0 / / % i MADE, THE PROFESSIONAL ENGINEER MUST SIGN AND SEAL, DATE AND DESCRIBE THE FULL EXTENT OF THE ALTERATION 0 / �' � j GOND T 6W!' / GONDJriA-y'9fiYy ONOOIr-7=36W z / ,� / / /- / / I ON THE DRAWING AND/OR IN THE SPECIFICATIONS. I� I L (NYS EDUCATION LAWSECTION 7209-2) ATTENDANT // / // AREA ' /////� I // / M SALES AREA N I I — / // / / 101 / / / / / / GONDOLAS /� 6„/\ / G DOLA-i ! GONDQL'A.T96W / O NDOLA-T36W WALK-IN FREEZER I o0 (2) 30 COOLER (DOORS 10'-5 3 8" I I / I� I - - - - - - - - - / / / / SITE ADDRESS SINL / / ENTRY DOOR / I I I _ _ ___ _ _ _ ______ __ PROPOSED CONVENIENCE -- - - - — ----- — STORE WITH FILLING STATION I IIr=-T-====ii I III 1 �II I it 1 I I I I - - - - - - i ii ----- - ------- --------------------------- KI III xI �II -------- ------------- - - 7400 MAIN ROAD III 1 1 III I III 1 -1 111 r----- -------- IL—=—.==J I ILc=b=====J I MATTITUCK, L_--__-____J L----------J TOWN OF SOUTHOLD SUFFOLK COUNTY, NY Imo_ �-- --� _ L--------------J L--------------ji DISTRICT: 1000 BLOCK: 07 SECTION: 122 LOT: 3.2 SCALE AS NOTED HPE ` EMP021-01 43-9 1/2 " DAB' 10/9/2023 DWG 11_DAP021 Fla-P1.0 P WN BK. JJC CHECKED BY. MG/CT 47'-4 1/2" 8'-0" 55'-7 3/4" -OL 56'-4" q�i.I��L�� BUILDING FLOOR AREA ANALYSIS: 57'-8" MV 16 2026 FIRST 58'-4„ .01 FIRST FLOOR BUILDING AREA = 2,800 SQ.FT. 10� In SOUTHOLD TOWN FLOOR PLAN SECOND FLOOR BUILDING AREA = 2.106 SQ.FT. PLANNING BOARD RETAIL AREA = 1,231 SQ.FT. SHEET NO• 1 FIRST FLOOR PLAN A-2.o SCALE: 1/4"=1'-O" Q ❑O c9 ,� LLJJ HIGH s' EQ POINT w ENGINEERING 1860 WALT WHITMAN ROAD SUITE 600 MELVILLE,NY 11747 (516)777-4320 FAX: (516) 777-4321 ALL PHASES OF ENGINEERING DESIGN, SURVEYING, CODE CONSULTING, ZONING ANALYSIS &BID SPECIFICATION www.HPEng.com CHRIS M. TARTAGLIA 0� N E w,,O — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — -- � C' 0�829_Yq, — — — — — — — — — — — — — PROFESSIONAL ENGINEER NEW YORK LICENSE No. 078209 I LAWRENCE D. O 'BRIEN 9'-2 3/4" g'_3" 38'-5 3/4" I I I .o. 81—Ob o I • I00 / PROFESSIONAL ENGINEER NEW YORK LICENSE No. 082537 _ `RESTROOM — JI I 202 / UNLESS APPROVED BY ALL AGENCIES HAVING JURISDICTION, THESE PLANS ARE NOT TO BE UTILIZED FOR CONSTRUCTION. OWNER CONTRACTOR ARE RESPONSIBLE FOR CONFIRMING ALL REQUIRED AGENCY APPROVALS HAVE BEEN SECURED PRIOR TO COMMENCEMENT OF WORK, WHETHER DESCRIBED ON THESE PLANS OR OTHERWISE. LO REVISIONS — — W 8'-6 5/8" — — N — REV NO. DATE REVISION ON z — — o — — 1 5/23/2024 Per Town Comments — — — — — 2 111212026 Misc. Coordination — N c 100 \ I O 00 do I I OPEN STAIRWELL — OFFICE AREA *00 00 I 001 201 I M 238 SQ.Ff. I I 1,868 SQ.FT. 'I - I I II I I I II I THE EDUCATION LAW OF THE STATE OF NEW YORK PROHIBITS ANY PERSON ALTERING ANYTHING ON THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATIONS, 9'-6 3/8" UNLESS IT IS UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. WHERE SUCH ALTERATIONS ARE MADE, THE PROFESSIONAL ENGINEER MUST SIGN AND SEAL, DATE AND DESCRIBE THE FULL EXTENT OF THE ALTERATION ON THE DRAWING AND/OR IN THE SPECIFICATIONS. (NYS EDUCATION LAW SECTION 7209-2) 4 56'-5 1/2" Ij le 8'-5 3/4" I \ 8'-5 3/4" I •; I \ " re) rl 1 Iz— � SITE ADDRESS• PROPOSED CONVENIENCE STORE WITH FILLING STATION - - - - - - - - - - - - 7400 MAIN ROAD MATTITUCK, TOWN OF SOUTHOLD SUFFOLK COUNTY, NY DISTRICT: 1000 BLOCK: 07 SECTION: 122 LOT: 3.2 3'-2 1/2" 8'-5 3/4" 8'-5 3/4" 3'-2 1/2" MAIL AS NOTED HPE EMP021-01 3-=1/2' 10'-0" 31'-8" 10'-0" .* 10/9/2023 DWG ' _ Floor 1.0 _ - tom- .o lan 01 58'-1» DRAWN BY JJC CHECKED BY. MG/CT 01 I1I1� Ow ED SECOND NOV 16 2026 FLOOR PLAN SOUTHOLD TOWN PLANNING BOARD SHEET N0 SECOND FLOOR PLAN 1 SCALE: 1/4"= 1'-0" 0 LED GOOSENECK TYPE WALL SCONCE (TYP. OF 3) SURFACE MOUNTED EXTERNALLY ILLUMINATED WALL SIGN HIGH I G n u 2'-4" x 7'-6" = 17.5 SQ.FT, n Q T.O.. RIDGE _ nr (ELEV. +33'-6" 1"x 3" AZEK TRIM OVER 5/4% 8" POINT AZEK TRIM RAKE BOARD + COLOR: AUTUMN TAN BY JAMES HARDIE ENGINEERING 1"x 6" AZEK RAKE TRIM COLOR: AUTUMN TAN BY JAMES HARDIE 1860 WALT WHITMAN ROAD SUITE 600 MELVILLE,NY 1.1747 (5l6) 777-4320 FAX: (516) 777-4321 ALL PHASES OF ENGINEERING DESIGN, SURVEYING, CODE CONSULTING, - --- ZONING ANALYSIS & BID SPECIFICATION www.HPEng.com ROOFING MATERIALS TYP.: CHRIS M. TARTAGLIA „ r -------- - ---- - MFR: GAF BUILDING PRODUCTS -'- - TYPE: TIMBERLINE HDZ - LAMINATED ASPHALT � rJ NEy1,},, y ARCHITECTURAL ROOF SHINGLES ATOP #30 ROOF FELT P Rf ®''f-N UNDERLAYMENT AS PER MFR. SUGGESTED INSTALLATION I.. p�"* --- ATOP 5/8" EXT. GRADE PLYWOOD SHEATHING. -A - -- - ` � 4U r _ Pao — �•�,� /~rl�► — COLOR: CHARCOAL U' B.O. SOFFIT �' /'G' — 6" GUTTERS AND LEADERS 9 �� RT$2a ELEV. +15 —6 �p�� PROFESSIONAL ENGINEER NEW YORK LICENSE No. 078209 --- -- -- - -- -- --- LED WALL PACK LIGHT FIXTURE (TYP.) LAWRENCE D. O 'BRIEN jk T.0). STOREFRONT ELEV. +10 -0 1 2 ;, -- -- 5/4" X 6" PVC CORNER BOARD TRIM TYP. MFR: AZEK QUICK-CORNER W/ INTEGRAL J-CHANNEL COLOR: WHITE FIBER CEMENT LAP SIDING BY JAMES HARDIE PROFESSIONAL ENGINEER STYLE: SELECT CEDARMILL NEW YORK LICENSE No. 082537 ® I COLOR: LIGHT MIST W/ 6" EXPOSURE) CULTURED STONE CHISELED EDGE WAINSCOT SILL UNLESS APPROVED BY ALL AGENCIES HAVING JURISDICTION, THESE PLANS ARE NOT TO BE UTILIZED FOR CONSTRUCTION. (BY: ELDORADO STONE COLOR - EARTH) OWNER/ CONTRACTOR ARE RESPONSIBLE FOR CONFIRMING i ; ALL REQUIRED AGENCY APPROVALS HAVE BEEN SECURED PRIOR TO COMMENCEMENT OF WORK, WHETHER DESCRIBED T.O. SLAB / CONC. WALK @ENTRY BRICK VENEER ON THESE PLANS OR OTHERWISE. © ELEV. O'-0 (BY: GLEN-GERY - STANDARD 51-DDX/ RED) SLIDING BI-PARTING ALUMINUM ENTRANCE STOREFRONT W/ TRANSOM LEMERGENCY SHUT OFF SWITCH REVISIONS REV N0. DATE REVISION 1 512JI2024 Per Town Comments 2 111212026 Misc. Coordination 1 FRONT ELEVATION (NORTH) SCALE: 1/4" jk T.O.. RIDGE ELEV. +33'-6" THE EDUCATION LAW OF THE STATE OF NEW YORK PROHIBITS ANY PERSON ALTERING ANYTHING ON THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATIONS, UNLESS IT IS UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. WHERE SUCH ALTERATIONS ARE MADE, THE PROFESSIONAL ENGINEER MUST SIGN AND SEAL, DATE AND DESCRIBE THE FULL EXTENT OF THE ALTERATION ON THE DRAWING AND/OR IN THE SPECIFICATIONS. (NYS EDUCATION LAW SECTION 7209-2) 12 812 B.O. SOFFIT --- - ------ — © ELEV. + -6 SITE ADDRESS.- PROPOSED CONVENIENCE STORE WITH FILLING STATION 7400 MAIN ROAD MATTITUCK, TOWN OF SOUTHOLD -- ------------ SUFFOLK COUNTY, NY DISTRICT: 1000 BLOCK: 07 SECTION: 122 LOT: 3.2 SCALE' AS NOTED HPE EMP021-01 DATE.• 10/9/2023 DWG ' 02-EMP021-1-A-.0 ns DRAWN BY. JJC CHECKED BY. MG/CT _ EXTERIOR T.O. SLAB CONC. WALK @ ENTRY ELEVATIONS ELEV. 0 -0 SECOND FLOOR NOV 16 1OZ 6 I ENTRY DOOR SOUTHOLDTowi PLANNING BOARD y SHEET NO. 2 LEFT SIDE ELEVATION EAST RE10) HIGH a' E-0 T.O. RIDGEE @ EL.EV. +33'-6" POINT 3 ENGINEERING 1860 WALT WHITMAN ROAD SUITE 600 MELVILLE, NY 11747 (516) 777-4320 FAX: (516) 777-4321 ALL PHASES OF ENGINEERING DESIGN, SURVEYING, CODE CONSULTING, ZONING ANALYSIS &BID SPECIFICATION www.HPEng.com CHRIS M. TARTAGLIA /r 4 � A *� r cs �'�a•s.: � B.O. SOFFIT -- -}-_ Q78200 N�J@ ELEV. +15'-6" PROFESSIONAL ENGINEER NEW YORK LICENSE No. 078209 LAWRENCE D. O'BRIEN PROFESSIONAL ENGINEER NEW YORK LICENSE No. 082537 UNLESS APPROVED BY ALL AGENCIES HAVING JURISDICTION, THESE PLANS ARE NOT TO BE UTILIZED FOR CONSTRUCTION. OWNER/ CONTRACTOR ARE RESPONSIBLE FOR CONFIRMING ALL REQUIRED AGENCY APPROVALS HAVE BEEN SECURED PRIOR TO COMMENCEMENT OF WORK, WHETHER DESCRIBED T.O. SLAB CONC. WALK ® ENTRY Ai A ON THESE PLANS OR OTHERWISE. @ ELEV. 0 —0 ELECTRIC SERVICE, WALK—IN COOLER CONDENSERS REFRIGERATION CONDENSERS METER, MDP AND MTS REVISIONS REV NO DATE REVISION 1 512JI2024 Per Town Comments 2 111212026 Misc. Coordination 1 REAR ELEVATION SOUTH) SCALE: 1/4 = 1-0 T.O. FRIDGE_ _- - @ ELEV. +33'-6" THE EDUCATION LAW OF THE STATE OF NEW YORK LED GOOSENECK TYPE WALL SCONCE (TYP. OF 3) PROHIBITS ANY PERSON ALTERING ANYTHING ON THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATIONS, UNLESS IT IS UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. WHERE SUCH ALTERATIONS ARE SURFACE MOUNTED EXTERNALLY ILLUMINATED WALL SIGN MADE, THE PROFESSIONAL ENGINEER MUST SIGN AND SEAL, 2'-4" X 7'-6" = 17.5 SQ.FT. DATE AND DESCRIBE THE FULL EXTENT OF THE ALTERATION ON THE DRAWING AND/OR IN THE SPECIFICATIONS. (NYS EDUCATION LAW SECTION 7209-2) 12 8 T=� 12 6F jk a B.O. SOFFIT @ ELEV. +15 —6 SITE ADDRESS: PROPOSED CONVENIENCE STORE WITH FILLING STATION 7400 MAIN ROAD jk B.O. ENTRY SOFFIT MATTITUCK, @ ELEV. +10 —0 1 2 TOWN OF SOUTHOLD SUFFOLK COUNTY, NY 00 DISTRICT: 1000 BLOCK: 07 SECTION: 122 LOT: 3.2 AL AS NOTED HPE J.• EMP021-01 2• 10/9/2023 DWG #' 02—EMP021-01—A-2.0 — Elevations DRAWN BY: JJC CHECKED BY. MG/CT T.O. SILAB �E�� EXTERIOR @ ELEV. OONCO WALK ® ENTRY NOV � 6 2026 ELEVATIONS GAS METER SOUTHOLD TOWN I I PLANNING BOARD SHEET NO. 2 RIGHT SIDE ELEVATION WEST I r—1 R � :.EA HIGH 59 0 " POINT m ENGINEERING RIDGE CAP (TYP.) 1860 WALT WHITMAN ROAD SUITE 600 MELVILLE, NY 11747 (516) 777-4320 FAX: (516) 777-4321 ALL PHASES OF ENGINEERING DESIGN, SURVEYING, CODE CONSULTING, ZONING ANALYSIS &BID SPECIFICATION www.HPEng.com 00 CHRIS M. TARTAGLIA WHITE ALUMINUM SOFFIT W/ FULLY ,�� RECESSED LIGHT Q` ��'_ DISPENSER ON 3'x5' FIXTURES CANOPY COLUMN PAINTED BLACK r _ $ STAINLESS STEEL (TYP. OF 4) �..,.,, �. FORMED CONC. ISLAND (TYP. OF 4) 078 0 P INEER NEW YO E No. 078209 00 Q LAWRENCE D. O 'BRIEN CD Ln l II PROFESSIONAL ENGINEER NEW YORK LICENSE No. 082537 UNLESS APPROVED BY ALL AGENCIES HAVING BOLLARD PAINTED O JURISDICTION, THESE PLANS ARE NOT TO BE UTILIZED LIGHT GRAY - . OWNER/ CONTRACTOR ARE ROESPONNSIB EU FOR NCONFIRMING ALL REQUIRED AGENCY APPROVALS HAVE BEEN SECURED PRIOR TO COMMENCEMENT OF WORK, WHETHER DESCRIBED ON THESE PLANS OR OTHERWISE. REVISIONS END ( NORTH AND SOUTH ) ELEVATIONS REV NO. DATE RE1ISION 1 6120124 PER TOWN COMMENTS SCALE: 3/8"=1'-0" 2 111JI26 REV SITE LAYOUT 38'-4 1 /4" ROOFING SHINGLES TO MATCH BUILDING COLOR: CHARCOAL RIDGE CAP (TYP.) THE EDUCATION LAW OF THE STATE OF NEW YORK PROHIBITS ANY PERSON ALTERING ANYTHING ON THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATIONS, UNLESS IT IS UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. WHERE SUCH ALTERATIONS ARE MADE, THE PROFESSIONAL ENGINEER MUST SIGN AND SEAL, DATE AND DESCRIBE THE FULL EXTENT OF THE ALTERATION ON THE DRAWING AND/OR IN THE SPECIFICATIONS. L\ (NYS EDUCATION LAW SECTION 7209-2) 00.1 CANOPY COLUMN WHITE ALUMINUM PAINTED BLACK (TYP. OF 4) SOFFIT W/ FULLY RECESSED LIGHT FIXTURES DO G u u' SITE A00 DDRESS � z S Q PROPOSED CONVENIENCE STORE WITH FILLING STATION BRICK VENEER o 7400 MAIN ROAD (BY: GLEN-GERM - MATTITUCK, Ln STANDARD 51 -DDX/ RED) TOWN OF SOUTHOLDSUFFOLK COUNTY, NY 11952 DISTRICT: 1000 BLOCK: 07 LL SECTION: 122 LOTS: 1 & 3.2 SCALE. 3/8"_1'_O" HPE# EMP021-01 Dom• 9/27/23 DWG #' EMP021-01-CR.2 DRA WN 8 Y. LD CHECKED BY. LC I TITLE.• CANOPY ELEVATIONS FRONT ANTA D REAR WEST AND EAST ) ELEVATIONS RENDERING ( MAIN ROAD/ OLD MAIN ROADS SHEET N0: SCALE: 3/8"=1'-0" NOV 16 2026 SOUTHOLD TUus'.A PLANNING BOARD REV• 2 OF 1 BULK REQUIREMENTS GENERAL NOTES 1. ZONE: GENERAL BUSINESS (B) DISTRICT 1. PROPERTY OWNER/ APPLICANT: HIGH 2. USE: AMAC INC. & 535 OLD MAIN REALTY LLC 2.1. PER 280-48(8)-12 - GASOLINE SERVICE STATION REQUIRES SPECIAL EXCEPTION BY BOARD OF APPEALS. P.O. BOX 547 / 2.2. PER 280-48(A).2(A) - RETAIL STORE > 1,200 SF CONSIDERED 2nd PRINCIPAL USE. LAUREL, NY 11948 POINT 3. BULK REQUIREMENTS: CODE SECTION: PERMITTED: PROVIDED: 2. THIS PLAN REFERENCES: moo• - A SURVEY PREPARED BY: ENGINEERING MIN. LOT SIZE: § 240-48-c-5 60,000 SF 63,308 SF (1.453 ACRES) NATHAN TAFT CORWIN III DATED: 8/9/23 N PROP. CONC. CURB MIN. FRONT YARD: § 280-50a 100' MAIN RD. (NYS 25) - FLOOR PLANS & ELEVATIONS PREPARED BY: (NYSDOT ITEM 74.7' (BLDG.)* THIS FIRM / 609.0401 TY 44.6' (CANOPY)* DATED: 5/23/24 (REV. 1) / ) (TYP.) 1860 WALT WHITMAN ROAD r OLD MAIN RD. 3. ANY BROKEN OR HAZARDOUS SIDEWALK, DRIVEWAY APRONS OR CURB ADJACENT TO THE SUBJECT SITE o ! SUITE 600 66.2' (BLDG.)* SHALL BE REPLACED IN ACCORDANCE WITH CURRENT COUNTY/ TOWN STANDARDS. MELVILLE NY 11747 33.8' (CANOPY)* 4. CURB-CUTS AND/ OR ACCESS TO TOWN, COUNTY, STATE, ETC. HIGHWAYS SHALL BE CERTIFIED BY THE / MEET EXIST. SIDEWALK/ GRADE/ ' MUNICIPALITY HAVING JURISDICTION. CURB/ ROADWAY FLUSH (516)777-4320 FAX: (516)777-4321 MAX. STRUCTURE FRONTAGE (LENGTH): § 280-50c 60' 58.3' (BLDG.) 5. DEBRIS SHALL NOT BE BURIED ON THE SUBJECT SITE. ALL UNSUITABLE MATERIAL AND DEBRIS SHALL BE 59.0' (CANOPY) DISPOSED OF IN ACCORDANCE WITH ALL LOCAL TOWN, COUNTY, STATE AND FEDERAL LAWS AND APPLICABLE E CODES. ErN%t SPED LtMI'r MIN. STRUCTURE SETBACK FROM R.O.W. § 280-50c 75' MAIN RD. (NYS 25) 6. THE OWNER/ CONTRACTOR SHALL BE FAMILIAR WITH AND RESPONSIBLE FOR ANY/ ALL CERTIFICATIONS, o -�,' X s. N/O/F ALL PHASES OF ENGINEERING DESIGN, 4p sIGN TO RFMAjv COPAM REALTY COMPANY SURVEYING,CODE CONSULTING, 75.9' (BLDG.) INSPECTIONS, ETC. REQUIRED BY ALL GOVERNING JURISDICTIONAL AGENCIES DURING AND AFTER � � 44.6' (CANOPY)* CONSTRUCTION FOR SIGN-OFF AND CERTIFICATE OF OCCUPANCY ISSUANCE, INCLUDING BUT NOT LIMITED TO / �'- 'p ZONE: GENERAL BUSINESS (B) ZONING ANALYSIS &BID SPECIFICATION PROCUREMENT OF SERVICES, SCHEDULING OF FIELD OBSERVATIONS AND COORDINATION WITH r 6'< OLD MAIN RD. REPRESENTATIVES OF THE APPROPRIATE PARTIES. S USE: McDONALDS RESTAURANT 66.2' (BLDG.)* 7. ENGINEER OF RECORD NOT RESPONSIBLE FOR PREPARATION, MONITORING OR REVIEW OF CONTRACTOR'S 33.8' (CANOPY)* SITE SAFETY PLAN. CONTRACTOR ACKNOWLEDGES THAT COMPLETE RESPONSIBILITY FOR JOB SITE SAFETY r �O.O www.HPEng.com HIMSELFLIES WITH AND THOSE MIN. LOT WIDTH: § 280-ATTACHMENT 4 150' 462.42' 8. THE CONTRACTORIS RESPONSIBLE I DIRECTION.EFOR VERIFYING AND DEPTH OF ALL UNDERGROUND f F APPURTENANCES (WHETHER DEPICTED ON THESE PLANS OR NOT) PRIOR TO THE START OF WORK. THE VPROP. HOT BOX`` �9O CHRIS M. TARTAGLIA MIN. LOT DEPTH. § 280-ATTACHMENT 4 150' 95.20' CONTRACTOR MUST CONTACT THE "ONE CALL" SYSTEM TO ENSURE THAT ALL UTILITIES ARE PROPERLY AND W/ RPZ DEVICE MIN. SIDE YARD: § 280-ATTACHMENT 4 25' 25' (BLDG.) COMPLETELY MARKED OUT PRIOR TO PERFORMING ANY WORK. ANY DISCREPANCIES BETWEEN THE FIELD LOCATIONS AND THE PLANS MUST BE VERIFIED BY THE CONTRACTOR. ANY DAMAGE OR STRUCTURE \1 / l aF NEW1_ DISTURBED DURING CONSTRUCTION MUST BE REPAIRED OR REPLACED AT THE CONTRACTOR'S EXPENSE. SHADED AREA •Ce`G Q 124.6' (CANOPY) 9. CONTRACTOR TO COORDINATE W/ ENVIRONMENTAL CONSULTANT TO CONFIRM IF EXISTING MONITORING WELLS / DEPICTS PROPOSED MIN. REAR YARD: § 280-ATTACHMENT 4 35' N/A (CORNER LOT) DISTURBED/ REMOVED DURING CONSTRUCTION MUST BE REPLACED. /, STORMWATER a INFILTRATION BASIN / MIN. LANDSCAPE AREA PERCENTAGE: § 280-ATTACHMENT 4 35% 36,742 SF (58.0%) zzxfit MAX. LOT COVERAGE: § 280-ATTACHMENT 4 30% 7,169.2 SF (11.3%) /� '� r MAX. BLDG. HT./ STORIES: § 280-ATTACHMENT 4 35'/2 STORIES 33'-6"/2 STORIES CORNER LOT SIGHT LINE DISTANCE: § 280-106(A) 30' SIDES COMPLIES PROP. CONC. CURB / /�%' \ / 0782®� (NYSDOT ITEM / PROP. 9'X19 �/ / MIN. ACCESSORY STRUCTURE SETBACK § 280-15(B) 20' 25' (TRASH ENCLOSURE) #609.0401) (TYP,) �` LANDBANKED P INEER.9 FOR SIDE AND/OR REAR YARD i PARKING STALL s NEW YO E No. 078209 G �t FOR LOT SIZE 60,000-79,999 SF a ' � (TYP. OF 12) '� / MIN./ MAX. DRIVEWAY WIDTH: § 280-48(B)12(a) 12'/30' 30' (MAIN RD. NYS 25) ; / / ' // / LAWRENCE D. 0 BRIEN 30' (OLD MAIN RD.) LINE OF EXIST MIN. DRIVEWAY DIST. FROM ADJACENT �: § 280-48(B)12(a) 10' 172.0' a zt 7 r s `kfi'° sy 147Y1 #r DENSE VEGETATION • - ,2 =�� � � � q„;, ys, ,,,, Y ,` F� a�. : .. ., ...;s ,,:.... . �i PROP. � \ CIVIC �ti LANDSCAPE AREA To REMAIN nr"y MIN. TANK DIST. FROM ADJACENT R. § 280 48(B)12(e) 35 105.5' ,, ,. � �r � � > � < �t7 F � �?, ; ',1 ��;`(t� 1 i „ { � ¢ ` v" w ,,,,, Y, PROP. LOCATION OF / t (TYP.) V MIN. DISP. DIST. FROM R.O.W. F'L: § 280-48(B)12(f) 15' 46.1' q r� Sr GRAVELDISCHA PIT IN E & } N` Yy k R�., O MIN. TANK FROM R.O.W. R § 280-48(B)12(f) 15' 15' N s ', '�. � � �� � INFILTRATION BASIN H 280 48 B 12 300' 1.5 MILES MATTITUCK-CUTCHOGUE $ 6-MIN DIST FROM CHURCH, § ( ) (g) ( � °� e NOV 16 2026 SCHOOL, ETC. Q END PROP. FENCE JR./SR. HIGH SCHOOL) �° J PARKING & LOADING „ } AT EXIST. SOUTHOLD TOWN i PLANNING BOARD 0-78 a 1 100 GFA `. 20'R �\ VEGETATION LINE PROFESSIONAL ENGINEER MIN. # OF STALLS-CONVENIENCE STORE § 28 O / o �� .: r � �� •• l 2,800/100 uj �",. SOLID PVC NEW YORK LICENSE No. 082537 28 STALLS "O� O'�' 3'R , / v �`o FENCE ALONG R UNLESS APPROVED BY ALL AGENCIES HAVING MIN. # OF STALLS-OFFICE § 280-78(a) 1/10o GFA Gja0�\� \ J JURISDICTION, THESE PLANS ARE NOT TO BE UTILIZED 33'R 1O'R FOR CONSTRUCTION. OWNER CONTRACTOR ARE 2,106/100 = ©O 1 G� RESPONSIBLE FOR CONFIRMING ALL REQUIRED AGENCY � �y5 - EXIST. URL17Y'Poi, 22 STALLS Q ya �'`' r0 R,1MA;N 4k F,� APPROVALS HAVE BEEN SECURED PRIOR TO - ��p /� �3 PROP "STOP' SIGN�� �, DO COMMENCEMENT OF WORK, WHETHER DESCRIBED ON MIN. # OF STALLS-GAS STATION § 280 78(a) 1/EMPLOYEE - O F ' �� FACING SOUTH PROP 20'x41' '� N� THESE PLANS OR OTHERWISE. 3 STALLS \�P LOADING STALL O j, REVISIONS 53 STALLS 36 STALLS (INCL. 2 ADA + �p� rr. / ''. ;� 1O'R Od0 12 12 LANDBANKED STALLS* 4 `; \ C\ "'' G S j o \p O� O REV NO DATE REVISION PROP. SAWCUT & ASPHALT FF `cs. ;� PROP. LOADING RAMPS O� add LEGEND MIN. STALL SIZE: § 280-78(c): 9'x19' 9'x19' PAVEMENT REPLACEMENT \�P \� \ / a � � � ' '"/ ALL ITEMS EXISTING TO REMAIN UNLESS NOTED OTHERWISE 1 10/24/23 MISC. REVS MIN. LOADING STALLS: § 280-79(A)3: 4,906 SF < 5,000 SF N/A (NYSDOT ITEM / / O PROP. 10'x20'x6'H ( ) #203.50140363) 6® MASONRY TRASH 2 512JI24 PER TOWN COMMENTS MIN. OF STREET TREES: § 280-93: 1 40' LOT FRONTAGE: 14 STREET TREES* ® �� ENCLOSURE ON # / � PROP. CONC. CURB RAMP • „� •�' `>., � � O � CONC. MAT PROPERTY LINE 3 7/23/26 REV SITE LAYOUT 1,077.93' 40' = 27 TREES o >, (NYSDOT TYPE 1 �dc �p on OVERHEAD LINE CONFIGURATION Wj / w �s J �f u / HATCHED AREA FRONT LANDSCAPED AREA. § 280-93(B): 25 ALONG FRONT LOT LINE MAIN RD. (NYS 25) OPTION C: CURB RETURN / "' �'<�,'>- �l , ` /✓ s DEPICTS ALLOWABLE ;' cd UTILITY POLE 25.0' & OPTION 2 DETECTABLE �' �� �� BUILDING ENVELOPE ' OLD MAIN RD. WARNING PLACEMENT) GUY WIRE 10.0 p (TYR OF, $) Y ® INLET 25 , 4 �, �• �a o pC, ® � ���. TRASH PROP CONDENSING 5 R ?; UNITS ON CONC. MAT FRONT LANDSCAPED AREA: § 280-93(B): LANDSCAPE AREA OF 5' WIDE NONE PROVIDED* / PLO ENCLOSURE) SIGN ABUTTING THE FRONT OF THE yc�0� �y / 5 h !y, S� MCA BUILDING „ " CONCRETE CURB O PROP. STOP SIGN r \o LANDSCAPED PARKING AREA. § 280 95(A). 10 SF INTERIOR LANDSCAPE NONE PROVIDED* . , , Q� `L ;, � FACING SOUTH � ,;; g ,: ', �. ,, ., r � � . PROPOSED CONCRETE CURB AREA PARKING SPACE PROP. 2 STORY 10 SF/x 53 SPACES = 'f� Q,�Q�c. � / PROP. CON� <, �, ✓, s- ��. � EXIST. ID SIGN TO BE PROP. TRASH r �r 0 CURB (TYP. BUILDING - PROPOSED FLUSH CONCRETE CURB 530 SF 9 6'- O '�E � r N/0/F REMOVED RECEPTACLE 0,�, : (4,906 SF G.F.A.) STA LE * INDICATES VARIANCE REQUIRED O N Y J. FLISS JR. PROPOSED AREA LIGHT W/ SHIELD J TYP. F � , A r �1 I 'I l I,I I � I 0 2 I� � f rti ( ) POP. 2 263.2 SF •, " ,• � �i+ 8c JANICE M. FLISS 40 EXIST. PROPANE R 0 STORAGE CAGES' '` 33,R CANOPY OVER' 100 FRONT YARD SETBACK ZONE: GENERAL BUSINESS (B) PROPOSED WALL MOUNTED AREA LIGHT ' " -� - � „� ��� ` ' TO BE RELOCATED USE: RESIDENCE 3'R CONC. FUELING MAT r e �� -1st FLOOR 2,800 SF ��� � CONVENIENCE STORE PROPOSED CONCRETE PAVEMENT 10 R :;� L�Q� ° RETAIL. AREA: 1,231 SF 6 O O _2 F I PROPOSED GRASS AREA IN R.O.W. THE EDUCATION LAW OF THE STATE OF NEW YORK PROHIBITS ANY PROP. SINGLE ;5 0 � ,,, ,� nd FLOOR 2.106 SF r I aj� "- �� PERSON ALTERING ANYTHING ON THESE DRAWINGS AND/OR THE FIXTURE AREA O OFFICE LL A : 236 SF r, : 25 ACCOMPANYING SPECIFICATIONS, UNLESS IT IS UNDER THE 0 STAIRWELL AREA. 238 SF .,•: �fi: 1G 0 ® DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. WHERE SUCH LIGHT w/ BLDG. PROPOSED ASPHALT PAVEMENT IN \ O (NO BASEMENT) �, ALTERATIONS ARE MADE, THE PROFESSIONAL ENGINEER MUST SIGN /,". SHIELD: TYP. NYSDOT R.O.W. r,�e4l • CCy� �.. ( ) � � ��A AND SEAL, DATE AND DESCRIBE THE FULL EXTENT OF THE /� ,��` �'r�;+ w.,,, � 'L ,,.,, �, �J �. �tr' •' �; ,. ALTERATION ON THE DRAWING AND/OR IN THE SPECIFICATIONS. v O Vic. �, � "`� �•~�,, 1 �, >:.. �,;,: PROPOSED ASPHALT PAVEMENT IN NYS EDUCATION LAW SECTION 7209 2 �• : '�• . • :, ., � � _, ; � �z�sr, MANwo>�covE� O �c �, " ti , ,.,..,, . ,, , � > $R '' TOWN R.O.W. WIDE-- 1� :. / 7 LINE OF PORTICO/ ROOF TO BE REMOVED r OVERHANG (TYP.)CONC. SIDEWALK.. � ��° ` ' • � (NYSDOT ITEM PROP. RE. �p �a" >� _ _ _ _ w �� PROPOSED PARKING STALL COUNT 608.01000010 �:„ ,, , PROP. U-BOLLARD (TYP.) �, •„�r,, tk J O v PROPOSED SOLID PVC FENCE t`V R �' c'- „ END PROP. FENCE SHADED AREA gl ��P, c^•y � AT EXIST. ��- ,- PROPOSED SIGN DEPICTS PROPOSED''t G / VEGETATION LINE , ® PROPOSED PIPE BOLLARD STORMWATER f Q ., I: .,, � , #fi'` .,Y..7. 'k:}. ...r.. ,.,, .. .F ....� �. •f ,Q r '� . �,..,, „� � ��, � INFILTRATION BAST. :,... , .. ` "� _ t P OA' r:. Q PROPOSED INLET .,. :..s. ,. 3 . PROP. BICYCLE PARKING SIGN v `. , :o- p PARKING &'LOADING Q, �' MOUNTED TO POST MUTCD D4-3 ® PROPOSED SOLID COVER O STALLS I ( ) n, PROP. 3'x5' CONC. `� Qo PROPOSED FLAG POLE '<°' Exlsr. , PROP. INVERTED 'U' BICYCLE h- n 1 ISLAND W 1 MPD / ( ) v „ Q LIMIT OF VEGETATION �l GUARDRAIL TO . �, ,,,, ' ,� U � \ „ , s, RACK ON CONC. PAD;• .. � TYP. OF 4 BE;RE REMOVED / Q o PROP. CONIC. CURB 0 ,, PROPOSED BIKE RACK NYSDOT ITEM ,. "u,", ; (TYP. OF 2)( PROPOSED U BO LARD PROP. LOCATION OF = ,.6O9,Q401 TY . PROP BRICK c� m, , � . ,,;, 4,� ;: � ,r". :fir ,, r PROPOSED AIR STATION DISCHARGE PIPE & 1 R' ENCASED,CANOPY130 ,,� � ;,.v ;"€ .: .• Q v 0 GRAVEL PIT IN ., ,.. `v PROPOSED VACUUM STATION COLUMN TYP OF 6 PROP,°GRASS, AREA NYSDO� ,., � ,�: ,,,, ( ) , ,, ;- , .,�, .- ❑Q • � . � �'; INFILTRATION BASIN „ PROP. VACUUM Q •':� � t,.. . � sm,� 4 �, � m kTEM #610.16010020) (TURF< $TABLISHMfNT TYP.); STATIONS ON • W SITE ADDRESS. ..) ( �, n PROP. RELOCATED CONC. PEDESTALS � 'STORAGE 1"ANK6"�', � o � 1M ® ono_ a U1#DlrR fiC�NOR MST N' PROPANE-CYLINDER EXCHANGE CAGES v, v PROPOSED CONVENIENCE STORE 5'R LINE of EXIST. w/ PIPE BOLLARDS WITH FILLING STATION < q EXIST. AREA - DENSE KEGETAT/ON � O a TO REMAIN EXIST, BUILDING :( REMOVED " PROP. STOP SIGN *��' �' ROAD PROP. CONC. CURB RAMP 7400 MAIN � MATTITUCK, (NYSDOT,TYPE 1 CONFIGURATION �ROP. AIR " • ti Sp W ,87.22_. , , W ,,ACT. ,�:.I � . .,.• ,: . � .;,,... • . , - ,:_ , 197.14' ,. � TOWN OF SOUTHOLD W/ OPTION A. FLARED CURB & �/ �; , • I S 87 14 / � ' jr.PR LANDSCAPE / '(x Ji VACUUM SUFFOLK COUNTY, NY 11952 OPTION 1 DETECTABLE WARNING PLACEMENT / STATIONS ON Will T AREA (TYP.) XIS. / PROP. 30 i (NYSDOT ITEM #608.010500009) ' • VERHEAD WIRE 'CURB CUT / 8�6 TO BE REMOVED ` 1 t R / �-/ �/ MEET EXIST. GRADE/ Total Dental Care DISTRICT: 1000 BLOCK: 07 rii / r / �� �,/ j�� --L- ROADWAY FLUSH of Mattltuck SECTION: 122 LOTS: 1 & 3.2 ✓/ PROP. GRASS AREA , , /�!�� i � 1. .�. • k, „ �'/ � / / � --�• PROP. SAWCUT & ASPHALT -+ ;/ `s' • IN R.O.W. (TYP.) / PROP. GRASS SCALE- 1 = 20' HPE# EMP021-01 i PAVEMENT REPLACEMENT PER TOWN McDonald 5 AREA IN R.O.W. `-' OF SOUTHOLD REQUIREMENTS (TYP.) Elmer's Custom PROP. CONC. CURB PER TOWN OF (TYP.) 169 8' Amish Furniture DATE. 12/13/23 DWG #' EMP021-01-R1.3 1 �/ i • , Q'S� a ` SOUTHOLD REQUIREMENTS �n�' DRAWN BY. GG CHECKED BY. CT / 1 �,,� �� EXIST. UTILITY EXIST POLE TO REMAIN FREESTANIDING Gulf u TITLE. s �. o 10/PRICE SIGN �"® � 1+'TO REMAIAV hl awsnd Faun' ! °° P I � EXIST. MONITORING untr Time C cte ��' / / �� ✓ WELL TO BE REMOVED (TYP. - SEE GENERAL Y Y �� PLAN % NOTE #9) TRAFFI �� SITE MAIN ROAD RENDERING PROP. THOL CURB PER TOWN OLD EXIST. TANK VENT OF SOUTHOLD REQUIREMENTS /�fc''`/Ort , RISERS TO BE REMOVED CFk 1 (TOWN JURISDICTION) EXIST. AREA LIGHT TO EXIST. DOUBLE WALL TRAFFIC FLOW ew r - BE REMOVED FIBERGLASS UNDERGROUND SAFETY IS IN YOUR HANDS.EVERY DIG. EVERY TIME. ON r EXIST. FLAG POLE TO STORAGE TANKS TO BE Laurel Links J1. SHEET N0: EXIST. PAVEMENT y BE RELOCATED REMOVED Country Club THE STATE OF NEW YORK REQUIRES NOTIFICATION BY EXCAVATOR STRIPING TO BE EXIST. MASONRY DESIGNERS, OR ANY PERSON PREPARING TO DISTURB THE EARTH'S REPLACED PLANTER TO BE SURFACE ANYWHERE IN THE STATE. OT, 11 KNOW WHAT'S BELOW" IN-KIND (NYSDOT REMOVED PUBLICSERVICE COMMISSION, ITEM #619.002) NEW YORK STATE CODE RULE 753 KEY MAP- no N.T.S REV. 3 OF 1 51Fl(' Engineering7-,V 7' L-El I 1860 Walt Whitman Road, Suite 600 Phone: (516)777-4320 Melville,NY 11747 Fax: (516)777-4321 Website: www.HPEng.com Email: info(a,HPEng.com TRANSMITTAL Via: Hand Delivery ❑ U.S. Mail ❑ FedEx Standard Overnight ® Pick Up ❑ To: Southold Town Planning Board Date: November 13, 2026 54375 NYS Route 25 Southold,NY 11971 Attention: Brian Cummings Re: Convenience Store with Filling Station Senior Planner 7400 Main Road Mattituck,NY 11952 SCTM: 1000-122.00-07.00-001.000 & 003.002 Project# EMP021-01 Enclosures: Ouantity Date No. Description 10 11/3/26 CR-1 of l(Rev.42) Canopy Elevations Rendering 10 7/23/26 SP-1 to SP-10 of Civil Package IO(Rev.#3) 10 11/2/26 A-1.0 to A-2.I(Rev.92) Floor Plan& Elevations 10 7/23/26 R-1 of I(Rev.#3) Site Plan Rendering Comments: Enclosed please find the above referenced items for your use in filing with the Town of Southold Planning Department for the referenced site. Please contact our office with any questions or concerns you may have. g rr S1 ned: /�f /'-,`���' � f�r`✓"Ni�,.,,�-.: Si+eJT Melizza 0,a' one P 13, NI— MCapone@hpeng.com pp ., cc: Charles R. Cuddy,—w/enclosures(via Fed-Ex& email) 11 IN V 16 f Emre Ilgin, Empire Oil—w/enclosures (via email) SO,,,, _ OFFICE LOCATION: µ MAILING ADDRESS: Town Hall Annexes P.O. Box 1179 54375 State Route 25 Southold, NY 11971 (cor.Main Rd. &Youngs Ave.) Telephone: 631 765-1938 Southold, NY ` www.southoldtownny.gov PLANNING BOARD OFFICE TOWN OF SOUTHOLD July 15, 2026 Charles R. Cuddy, Esq. P.O. Box 1547 Riverhead, NY 11901 Re: Proposed Site Plan for Mattituck Gas Station & Convenience Store 7400 NYS Route 25 and 535 Old Main Road, Mattituck SCTM#1000-122.-7-1 & 3.2 Dear Mr. Cuddy: I'm writing as a follow-up to the Planning Board Work Session on July 13, 2026 regarding the revised site plan design, identified as "Alternate Plan C," voluntarily submitted by the applicant June 17, 2026 for Planning Board review. With reference to the Planning Board's discussion, the Board advises that prior to commencing a full review of the application, the submission must first be deemed complete. Accordingly, the following materials must be provided to this Department in order to complete the application: 1. Provide an updated Site Plan Application form applicable to the revised proposal. 2. Provide an updated Full Environmental Assessment Form (FEAF) applicable to the revised proposal. 3. Provide a minimum of nine (9) prints of a complete site plan packet in accordance with §280-133 of the Town Code. Each submission shall bear the stamp, seal, and signature of the New York State licensed professional responsible for preparation of the plans. The submission shall include the following: a. Stormwater Management Plan pursuant to §236; b. Queuing Plan pursuant to §280-78(A); c. Sanitary Plan; Mattituck Gas Station & Convenience Store P a g e 12 July 15, 2026 d. Building, Elevations for the proposed canopy and building; e. Detailed Floor Plans for the first and second floors of the proposed convenience store and office; f. Landscape Plan —Although landscaping depictions and notes appear on the submitted site plan, they lack the level of detail required for review, A complete landscape plan shall identify all proposed plantings, including species, size, quantity, and spacing (on-center). The plan shall also specify the percentage of overall landscape coverage on the site, excluding landscaped areas proposed within the public right-of-way; g. Utilities Plan; h. Photometric Plan pursuant to Chapter 172. 4. Architectural Renderings Provide a minimum of five (5) detailed renderings depicting the proposed exterior of the convenience store, canopy, and site. If you have any questions regarding this Site Plan or its process, please do not hesitate to call this office. Fesp ectfull Brian Cummings Senior Planner Southold Town Planning Board Work Session - July 13. 2026 - Pa 2 3:00 P.M. - Executive Session - Litigation 4:00 P.M. - Applications . .......................................... — ---------.......... ....... ........ ..... ..................... ............................................... ...... .............Pro Name: o n Sepenski standard Subdivision SCTM#: 1000-31.-1-5.9 mn ........................._­.......... Location: 7395 NYS Route 25, East Marion . ................ ...... ------ ................... --------- This proposal is for a clustered four-lot subdivision of 7.92 acres, where Descriptiow Lot 1 is 1.5 acres, Lot 2 is 0.5 acres., Lot 3 is 5.4 acres inclusive of 4.75 acres of open space, and Lot 4 is 0.5 acres. on 7.92 acres in the R-80 Zonina District. .................. ....................... -------- ...................... ------- ................................ Pending,", Status'. Plat mpleteness I Action: Review for Prelimin C o attachments- Staff Report ............... .................. .................... ............. ......... . ......... ---- ------------------------- Project Name. RQA Rich's Quality Autobody Site Plan SCTM#: 1000-102.-3-1 ....................... . ........ .......... . ..... Cutchogue Location-," 29950 NYS Route 25, . ..... .....................�11­...... Descriptiow, This site plan is to amend the previously approved plan to include several as-built structures, including a 972 sq. ft. portable building on a concrete slab, an extension of auto repair building #2 from 1,759 sq. to 2,916 sq. ft., along with the previously approved existing office building of 576 sq. ft. and existing auto repair building #1 at 1,628 sq. ft.; all on a 37,428 sq. ft. parcel in the R-40 Zoning District located on the s/s/o NYS 25 at the s/w intersection of NYS 25 and Fleets Neck Road in Cutchogue. ................................ ............... -------- Status:', Pending . .. ...................... ............. ... ............. .................................. .......... Action Review for Determination . ..........................Attachments,",, Staff Report ---------- ........ ............... ........ Project Name,,,, Mattituck Gas Station & Convenience SCTM#: 1000-122-7-1 & store3.2 ............... Location: 7400 Route 25 & 535 Old Main Road, Mattituck .............. .......... - 11-1-1-1-1 Description:', This Site Plan is for the proposed demolition of an existing 1-story 1,595 sq. ft. convenience store and gas station with 9 fuel pumps, the lot merger of SCTM#1 000-122.-7-1 and SCTM#1 000-122.-7-3.2, and the construction of a 2-story 5,000 gross sq. ft. building for office and convenience store with vehicle fuel sales a 152' x 24 (3,648 sq. ft.) canopy with 12 fuel pumps, and 34 parking stalls (12 of which are at the pumps) on 1.39 acres in the General Business (B) ZoningDistrict. ................... ...... ............. ........................................... ... ..... . .......... . Status: Pen. ........... ................................................. d ................... ing ...... ........------------ Action: Review Revised Plans ............................................ ---------- Attachments* i Staff Report Southold Planning Department Staff Report Site Plan Application Work Session —Application Update Date July 13, 2026 Prepared By., Brian Cummings I. Application Information Project Title: M attituck Gas Station & Convenience Store Applicant: Sukru Ilgin Date of Submission.- Tax Map Number: 122.-7-3.2 Project Location: 7400 Main Road Hamlet: Laurel Zoning District: General Business - B Il. Description of Project Type of Site Plan: Commercial Acreage of Project Site: ±1.39 acres (after merge) Building Size 5,000gsf building, 3,648sf Canopy III: Completeness Review See attached checklist for Site Plan Requirements. IV: Analysis This Site Plan is for the proposed demolition of an existing 1-story 1,595sf gas station and convenience store with 8 fuel pumps, the lot merger of SCTM#1 000-122.-7-1 and SCTM#1 000-122.- 7-3.2, and the construction of a 2-story 5,000 gross sq. ft. building for office and convenience store with vehicle fuel sales, a 152' x 24' (3,648sf) canopy with 12 fuel pumps, and 34 parking stalls (12 of which are at the pumps) on 1.39 acres in the General Business (B) Zoning District, Mattituck. 1 Existi a. SCTM#122.-7-1 i. 1-story 1,595 sq. ft. building ii. 4 pump islands (8 pump stations) + 1 kerosene pump iii. Two underground double wall fiberglass fuel storage tank b. SCTM#122.-7-3.2: vacant 2. Proosd: a. Merge two B zone parcels to form a single parcel at 1.39acres b. Construct 4,906 gsf building (no basement) i. 1st floor: 2,800sf convenience store and vehicle fuel sales ii. 2nd floor: 1,868sf office and 238sf stairwell c. One (1) canopy with 4 pump islands (8 pump stations) d. 10' x 20' dumpster enclosure e. Relocate two (2) existing double wall fiberglass fuel storage tanks i. Creation of three (3) formalized curb cuts to focus ingress/egress; revegetation proposed within Town and State ROW f. Two (2) Vacuums and two (2) air supply locations g. HVAC condenser units on proposed pad in rear of building 3. Reguired a1pprovais. a. Zoning Board of Appeals b. NYS Department of Transportation (DOT) i. Highway Work Permit for action within the ROW and creation of curb cuts c. Suffolk County Department of Health Services (SCHDS) i. Waste Water ii. Tank Division (Fuel Storage Tanks) .......................................... 2022 2023 Feb. 2025 Dec. 2025 June 2026 (Alt Concept 13) (Alt Concept 13) (Alt Concept C) Canopy 180'x24' 152x 24' 84' x 50' Canopy Canopy (4,320sf) (3,648sf) and (4,200sf relocation relocation' and seven (7) six (6) pump six (6) and decrease in size pump islands islands with pump decrease (dimensions/area with fourteen twelve (12) islands with to 74) x 50' unknown) (14) pump pump stations twelve (12) (3,700sf) stations pump 4 pump islands stations (8) pump stations Building 00gsf 5,000gsf(no 4,906gfa No change 4,906gfa change) I st-2,800sf 1 st-2,800sf Conv Conv Store Store 2nd-1 868sf 2nd-2,1 06 sf office 1 868sf office 238sf 238sf Stairwell Stairwell Parking 29 stalls (wl 2 34 stalls (wl 2 34 stalls No change 36 stalls (w/2 ADA) + 10 ADA) + 15 (w/2 ADA) + ADA) + 12 land land bank land bank 12 land bank bank stalls stalls stalls stalls Queuing plan Queuing plan provided; Loading No queuing Queuing plan provided; no Zone provided plan provided Loading —J—Zone d. Setbacks I Bulk Schedule Regu rement (Zone- B Conv. Store/Office Required Provided ��\.................................................... ......... Front yard Variable/1 00' 75.9' to Route 25 66.2' to Old Main Rd* SidIF6-0 25) > 25' 11--... .............. Side 25' (50 comb) >- 25' ............ � Rear and 35' >- 35' Canopy Front Yard 44.6' to Route 25* 33.8' to Old Main Rd* Denotes variance request for relief from ZBA VI: Items to consider 1. Provide feedback to the Applicant regarding the revised site plan proposal; 2. Require the applicant to provide a complete application for review that is consistent with the proposed revised site plan: a. Building Elevations, Floor Plans, Queuing, Landscaping, Drainage, Photometric, etc. 3 CHARLES R. CUDDY Attorney at Law 445 Griffing Avenue Riverhead, NY 11901 Mailing Address: Tel:(631)369-8200 PO Box 1547 Fax:(631,)369-9080 Riverhead,NY 11901 e-rnail:charl soudcl o @o ro8iw .r June 17, 2026 S„ HAND DELIVERED ° 17 2026 Brian Cummings, Town Planner SOUTHOLD TOWN Planning Department PLANWNG BOAR Town of Southold l 22' '7 -I 3 3 , Z 53095 Main Road Southold,NY 11971 ` Re: Mattituck Gas Station Dear Mr. Cummings: Based on my revised Site Plan, which 1 reviewed with Heather Lanza, I have obtained an updated Notice of Denial from the Town Bo iIding Department. The Notice,dated June 12,2026,is enclosed. In addition enclosed are nine(9)prints of the revised labelled ALTERNATE CONCEPT PLAN`C.' Please prepare a report so my clients will have an opportunity to discuss this proposal with the Planning Board. Very truly yours, Charles R. Cuddy CRC:dmc Enclosure c: Heather Lanza Jim Ilgin Emre Ilgin ., 6 F13 H WWI FORM NO. 3 d °° TO"OF SOUTHOLD JUN '17 2076 BUILDING DEPARTMENT" � + 'HOLD TOWN OUTHOLD,N.Y. PLANNING SOA D NOTICE OF DISAPPROVAL MATE: October 28, 2021 REVISED: November 3, 2021 REVISED: March 20, 2024 UPDATED: December 11, 2025 UPDATED: June 12, 2026 TO: Charles R. Cuddy (AMAC Inc.) 445 Griffing Avenue Riverhead,NY 11901 Please tape notice that your application received August 31, 2021: For permit to: .Me e tw 2��� a�ce �and construct a� � asp service�.c s t� n "grin- �gal se With d s x sor canopv. and a convenience store � r�i. i"',Pal use with associated second floor offices at: Location of property: 7400 C a n ', o,ad N ; tt t k-_NY County Tax Map No. 1000— Section 122 Block: 07 Lot 1 and 1000-122-7- .2 Is returned herewith and disapproved on the following grounds: Pursuant to Article XXIII, Section 80-127,the proposed use and merging of two lots require site plan approval from the Southold Town.Planning Board. Additionally, the proposed construction, on this (merged) 63,357 sq. ft. parcel in the B District, is not permitted pursuant to the Bulk Schedule, which requires a front yard setback of 100 feet and a side yard setback of 25 feet. The site plan shows the proposed convenience store to have a front yard setback of 75.9 feet to Main Road and a secondary front yard setback.of 66.2 feet to Old Main Road; the proposed canopy has a 44.6' front yard setback.to Main Road (Route 25)and a 33.8 foot secondary front yard setback to Cold Main Road. Lastly, and in addition, the gasoline service station must obtain special exception approval from.the Zoning Board of Appeals. This notice has been updated based can a revised site plan, received June 9, 2026 You may now a ply to these agencies directly. Autl �0ze ........................................................................................... * F" d,��Signature Note to.Applicant: Any change or deviation to the above referenced application, may require further review by the Southold Town Building Department. CC: file, Planning .Board, ZBA OF FICE LOCATION: slo MAILING ADDRESS: Town Hall Annex P.O. Box 1179 54375 State Route 25 Southold, NY 11971 (cor. Main Rd. &Youngs g Ave.) Southold NY Telephone: 631 765-1938 ' , www.southoldtownny.gov UNTI, PLANNING BOARD OFFICE TOWN OF SOUTHOLD March 10, 2026 Charles R. Cuddy, Esq. P.O. Box 1547 Riverhead, NY 11901 Re: Proposed Site Plan for Mattituck Gas Station & Convenience Store 7400 NYS Route 25 and 535 old Main Road, Mattituck SCTM#1000-122.4-1 & 3.2 Dear Mr. Cuddy: I'm writing on behalf of the Planning Board as a follow-up regarding the revised site plan design, identified as "Alternate Plan B, voluntarily submitted by the applicant in April 2025 and subsequently resubmitted with additional revisions on December 23, 2025 for q Y Planning Board review. With reference to the Planning Board's correspondence dated April 15, 2025, and the revised site plan submitted on December 23, 2025, the Board advises that, prior to providing rovidin substantive comments on the revisions and commencing a full review of the application, the submission must first be deemed complete. Accordingly, the following materials must be provided to this Department in order to complete the application. Please note that certain items identified in the April 15, 2025 correspondence (highlighted in bold) have since been satisfied and are noted as such below. 1. Provide a revised Notice of Disapproval for the proposed application. The current proposal differs from the plan previously reviewed by the Building Department and Planning Board that resulted in the Notice of Disapproval issued in 2021 and fast revised March 20, 2024. a. This item has been satisfied through the revised Notice of Disapproval updated December 11, 2025. 2. Provide an updated Site Plan Application form applicable to the revised proposal. a. This information has been provided in the December 2025 submission. Mattituck Gas Station & Convenience Store P a g e, 12 March 10, 2026 3. Provide a minimum of nine (9) printed copies of a complete site plan packet in accordance with §280-133 of the Town Code. Each submission shall bear the stamp, seal, and signature of the New York State licensed professional responsible for preparation of the plans. The submission shall include the following: a. Stormwater Management Plan pursuant to §236 — Not provided b. Queuing Plan pursuant to §280-78(A) — Provided c. -Building Elevations for the proposed canopy and building — Not provided d. Detailed Floor Plans for the first and second floors of the proposed I convenience store and office — Not provided e. Landscape Plan — Not provided. Although landscaping depictions and notes appear on the submitted site plan, they lack the level of detail required for review. A complete landscape plan shall identify all proposed plantings, including species, size, quantity, and spacing (on-center). The plan shall also specify the percentage of overall landscape coverage on the site, excluding landscaped areas proposed within the public right-of-way. f. Photometric Plan pursuant to Chapter 172 — Not provided 4. Architectural Renderings Provide a minimum of five (5) detailed renderings depicting the proposed exterior of the convenience store, canopy, and site. a. Not provided Until the above-referenced materials are submitted and the application is determined by this Department to be complete, the Planning Board is unable to undertake substantive review of the revised proposal or place the matter on a meeting agenda for consideration. The applicant is therefore requested to submit the outstanding materials at their earliest convenience so that the application may proceed through the review process. If you have any questions regarding this Site Plan or its process, please do not hesitate to call this office. Respectfully, Brian Cummings Senior Planner CHARLES R. CUDDY Attorney at Law 445 Griffing Avenue Riverhead, NY 11901 Mailing Address: Tel: (631)369-8200 PO Box 1547 Fax: (63 I 369-9080 + Riverhead,NY 11901 e-ma�1:��arreseudd�r t nline.n t S'..6; December 22, 2025 Ps W L.-I Isc I PAC DEC 2 3 2025 Brian Cummings, Town Planner SOUTHOLD TOWN Planning Department PLA14 NNING BOARD Town of Southold P.O. Box 1179 Southold,NY 11971 Re: Mattituck Gas Station Dear Mr. Cummings: I SLibmitt d a revised gas station plan to the wild nay Department and I have just received the 41- enclosed Notice of Disapproval advisl'ngy that site plan approval is necessary. The Denial letter also indicated the applicant will need area variances. Enclosed is the application with a separate cover letter. Please confirm you will be reviewing it so we may appear before the Planning Board. Very truly yours, Charles R. Cuddy CRC:dmc Enclosures CHARLES R.CUDDY ATTORNEY AT LAW 445 GRIFFING AVENUE RIVERHEAD,NEW YORK Malin Addres'S: TEL: (631)369-8200 P.O.Box 1547 PAX: (631)369-90800 Riverhead,NY 11901 E-mail: charlescuddy@optonline.net November 20, 2025 nER�[RDYIRED rDEC 2 3 2025 QU'fHOLDTQ�yNJames H. Rich III Chairman OUTH L TOWN BOARD Town of Southold Planning Board P.O. Box 1179 Southold,NY 11971 Re: AMAC Inc.-7400 Main Road,Mattituck,NY SCTM#1000-122-07-01 and 1000-122-7-3.2 Dear Chairman Rich: The owner of the gasoline service station at the Main Road(NYS Rte.25)in Mattituck,is submitting a revised plan in connection with the expansion of the service station. The plan also includes a new convenience store. In addition, we are submitting a letter addressing environmental concerns authored by Kim Gennare- }ancea of P.W. Grosser Consulting. In this connection we enclose the following: 1. Site plan application 2. Applicant Transactional Disclosure Form 3. Agent Authorization Letter 4. Applicant's Affidavit 5. LWRP Consistency Assessment Form 6. Long Environmental Assessment Form 7. Nine 9 prints of Site Plan S. Nine(9) prints of Vehicle Queuing Plan 9. Check in the sum of$550.00 representing a filing fee Please proceed with review of this application. Very truly yours, Charles R. Cuddy CRCIpc Enclosures SOUTHOLD PLANNING BOARD [:DEouC 2 3 2025 SITE PLAN APPLICATION FORM 'iHGLU TOWN LAHNIHG BARD Site Plan Name and Location Site Plan Name: Proposed gas station and Convenience Store Application Date: Suffolk County Tax Map#1000- 122 - 07 - 3.2 Other SCTM#s 1000-122-07-01 Street Address: 7400 Main Road Hamlet: Mattituck Distance to nearest intersection: Extends to Bray Avenue Type of Site Plan: New Amended_Residential Zoning District General Business Owners/Agent Contact Information Pease list name, nraili►1 ad-dress, and hone number far the people below: Property Owner AMAC Inc. and 535 Main Realty LLC Street PO Box 547 City Laurel State NY Zip 11948 Home Telephone 631-312-8852 Other Applicant AMAC Inc. and 535 Main Realty LLC Street PO Box 547 Ctty Laurel State Ny ZrP. 1194R Home Telephone631-312-8852 Other Applicant's Agent or Representative: Contact Person(s)* Charles R. Cuddy Street 445 Griffinq Avenue City Riverhead State NY Zig 11901 Office Telephone 631-369-8200 Other charIescuddy@Qptanfine.net Unless otherwise requested, correspondence will be sent only to the contact person noted here. Site Plan Application Form 2/I8/2010 Site Data Proposed construction type: X New X Modification of Existing Structure Agricultural ChaTii,7e of use Property total acreage or square footage: 63,357 aer./sq. ft. Site Plan build-out acreage or square footage, - same ac./sq. ft. Is there an existing or proposed Sale of Development Rights on the property? Yes No X If yes, explain: Does the parcel(s) meet the Lot Recognition standard in Town Code§280-9 Lot Recognition? Y—N If'.(.yes", explain(and attach any necessary documentation—title report, subdivision approval) etc.) Building Department Notice of Disapproval Date- 11 / 3 21 Is an application to the Southold Town Zoning Board of Appeals required? Yes No If yes, have you submitted an application to the ZBA? Yes No _X If yes, attach a copy of the application packet. Show all uses proposed and existing. Indicate which building will have which use. If more then one use is proposed per building, indicate square footage of floor area per use. List all existing property uses: gasoline service station and convenience store List all proposed property uses'. same as above Other accessory uses: N/A Existing lot coverage.- Q 7 % Proposed lot coverage.- 11.7 % Gross floor area of existing structure(s), 1600 sq. ft. Gross floor area of proposed structure(s) 4906 Parking Space Data: #of existing spaces: 3 #of proposed spaces. 34 1,oaclffl(l Berth: Yes No Landscaping Details: Existing landscape coverage: 2 % Proposed landscape coverage: 42 % Wetlands: Is this property within 500' of a wetland area? Yes No X Maybe 1) the undersigned, certify that all the above information is true. Signature of Pre parer- Date. �,Q�. 2 Site Plan Application Form 211812010 FORM NO. 3 TOWN OF SOUTHOLD BUILDlNG DEPARTMENT SOUTHOLD,,N.Y. NOTICE OF DISAPPROVAL DATE: October 28, 2021 REVISED: November 3, 2021 REVISED: March 20.,2024 UPDATED: December 11, 2025 TO: Charles R. Cuddy (AMAC Inc.) 445 Griffing Avenue Riverhead,NY 11901 Please take notice that your application received August 31, 2021: For permit to: Mcrae two (2) parcels and construct a oas service stafion.(principgI use), with dispenser canopy-, and a convenience-store fsecond princiml use with associated second floor offices at: Location of property: 7400 Main Road.Mattituck.NY County Tax Map No. 1000—Section 122 Block 07 Lot I and .1000-122-7-3.2 Is returned herewith and disapproved on the following grounds: Pursuant to Article XXIII, Section 280-127, the proposed use and merging of two lots require site plan approval from the Southold Town Planning Board. Additionally, the proposed construction, on this (merged) 63,357 sq. ft.parcel in the B District, is not permitted pursuant to the Bulk Schedule, which requires a front yard setback of 100 feet and a side yard setback of 25 feet. The site plan shows the proposed convenience store to have a front yard setback of 25 feet to Main Road with a side yard setback of 11.7 feet;the proposed canopy has a 3 8.6' front yard setback to Main Road (Route 25) and a 66.5 foot front yard setback to Old Main Road. Lastly, and in addition, the gasoline service station must obtain special exception approval from the Zoning Board of Appeals. This notice has been updated based on a revised site plan, received Nov. 25, 2025. You inay now apply to these agencies directly. Authorized Signature Note to Ap plicant: Any change or deviation to the above referenced application, may require further review by the Southold Town Building Department. CC: file, Planning Board,ZBA Southold P Applicant Transactional Disclosure Form The Town of Southold's Code of Ethics prohibits conflicts of interest on the part of town officers and employees. The purpose of this form is to provide information which can alert the town of possible conflicts of interest and allow it to take whatever action is necessary to avoid same. Your Name: AMAC Inc. and 535 Main Realty LLC Last,First,middle initial unless you are applying in the name of someone else or other entity, such as a company. If so, indicate the other person's or company's name. Nature of Application: (Check all that apply) Subdivision or Re-subdivision Site Plan X Other(Please name other activity) Do you personally(or through your company,spouse, sibling,parent or child)have a relationship with any officer or employee of the Town of Southold? "Relationship includes by blood,marriage or business interest. "Business interest"means a business,including a partnership,in which the town officer or employee has even a partial ownership of(or employment by)a corporation in which the town officer or employee owns more than 5%of the shares. Yes No If you answered"Yes"complete the balance of this form and date and sign where indicated. Name of the person employed by the Town of Southold Title or position of that person Describe the relationship between yourself(the applicant)and the town officer or employee. Either check the appropriate line A through D and/or describe in the space provided. The town officer or employee or his or her spouse,sibling,parent or child is(check all that apply): A.the owner of greater than 5%of the shares of the corporate stock of the applicant(when the applicant is a corporation); B.the legal or beneficial owner of any interest in a noncorporate entity(when the applicant is not a corporation); C.an officer,director,partner or employee of the applicant;or D.the actual applicant Description of Relationship: Submitted this day o�20A,;O' Signature Print Name Disclosure Form AMAC Inc. and 535 Main Realty LLC PO Box 547 Laurel,NY 11948 I. Enue Ilgin, on behalf of AMAC Inc. and 535 Main Realty LLC hereby authorize Charles R. Cuddy, Esq. to act as my agent on the property of S CTM#1000-122-07-3.2 and 1000-122-07-01 in Mattituck,New York, and handle all necessary work involved in the site plan process with the Southold Town Planning Board. IL�2 Emre Ilgin, Repro ntative on behalf of AMAC Inc. and 535 Main Realty LLC Sworn to before nee this day of q� 1--'A.&A may' , 2025 .F r r 0 Notary Public CHARLES-Ft. CURDY 16tary Public,Stabs of Now V9* Mv.02aCU5872225 Ou'afii i ed in Sullolk County APPLICANT'S AFFIDAVIT APPLICANT'S AFFIDAVIT STATE OF NEW YORK COUNTY OF SUFFOLK EMRE ILGIN, as Representative of AMAC Inc. and 535 Main Realty LLC being duly sworn, deposes and says thatAw faikfing mailing address is Po Box 547 Laurel NY 1148 in the State of New York, and that he is the owner of property located at 7400 Main Road, Mattituck Ny SCTM# 1000-122-07-3.2 , or that he is the Representative of the AMAC Inc. and 535 Main Realty LLC (Title) (Specify whether Partnership or Corp.) and said Corporation is the owner of the above property, which is hereby making a Site Plan application; that there are not existing structures or improvements on the land which are not shown on the Site Plan; that the title to the entire parcel, including all rights-of-way,has been clearly established and is shown on said Plan; that no part of the Plan infringes upon any duly filed plan which has not been abandoned both as to lots and as to roads; that he has examined all rules and regulations adopted by the Planning Board for the filing of Site Plans and will comply with same; that the plans submitted, as approved, will not be alter or changed in any manner without the approval of the Planning Board; and that the actual physical improvements will be installed in strict accordance with the plan as approved by the Planning Board. Signed Owner AMAC Inc. and 535 Main Realty LLC Signed (PartneowCorporate Officer and Title) Sworn to me this day of 2025 C&&- Notary Public CHARI.S R's CI DDY Watery Public.State of New York No.02CU5872225 Otiallfied in Sullolk County ComwojsW Expires December 3 F. Town of Southold 2W5 OEC LWRP CONSISTENCY ASSESSMENT FORM SOUTHcLu I OWN p N aNc BOARD A. INSTRUCTIONS I. All applicants for permits* including Town of Southold agencies, shall complete this CCAF for proposed actions that are subject to the Town of Southold Waterfront Consistency Review Law. This assessment is intended to supplement other information used by a Town of Southold agency in making a determination of consistency. '`Except minor exempt actions including Building Permits and other ministerial permits not located within the Coastal Erosion Hazard Area. 2. Before answering the questions in Section C, the preparer of this form should review the exempt minor action list, policies and explanations of each policy contained in the Town of Southold Local Waterfront Revitalization Program, A proposed action will be evaluated as to its significant beneficial and adverse effects upon the coastal area(which includes all of Southold Tpn ._ 3. If any question in Section C on this form is answered "yes" or "no", then the proposed action will affect the achievement of the LWRP policy standards and conditions contained in the consistency review law. Thus, each answer must be explained in detail, listing both supporting and non- supporting facts. If an action cannot be certified as consistent with the LAMP policy standards and conditions, it shall not be undertaken. A copy of the LWRP is available in the following places: online at the Town of Southold's website (southoldtown.northfork.net),the Board of Trustees office, the Planning Department, all local libraries and the Town Clerk's office. B. DESCRIPTION OF SITE AND PROPOSED ACTION SCTM# 1000 - 122 - 07-01 and 3.2 PROJECT NAME Proposed gas service station and convenience store The Application has been submitted to(check appropriate response): Town Board El Planning Board X Building Dept. Board of Trustees I. Category of Town of Southold agency action(check appropriate response): (a) Action undertaken directly by Town agency(e.g. capital construction, planning activity, agency regulation, land transaction) (b) Financial assistance(e.g. grant, loan, subsidy) (c) Permit, approval, license, certification: X Nature and extent of action: Extension of gas station and convenience store Location of action: 7400 Main Road, Mattituck, NY Site acreage. 1.5 ac, Present land use: Proposed gas service station and convenience store with vacant land Present zoning classification: General Business 2. If an application for the proposed action has been filed with the Town of Southold agency, the following information shall be provided: (a) Name of applicant. AMAC Inc. and 535 Maib Realty LLC (b) Mailing address: PO Box 547 Laurel, NY 11948 (c) Telephone number- Area Code(63)1 -4] 2-8,Ss? (d) Application number, if any, Will the action be directly undertaken, require funding, or approval by a state or federal agency? Yes 1�1 No X If yes, which state or federal agency?__ C. Evaluate the project to the following policies by analyzing how the project will further support or not support the policies. Provide all proposed Best Management Practices that will further each policy. Incomplete answers will require that the form be returned for completion. DEVELOPED COAST POLICY Policy 1. Foster a pattern of development in the Town of Southold that enhances community character, preserves open space, makes efficient use of infrastructure, makes beneficial use of a coastal location, and minimizes adverse effects of development. See LWR-P Section M-Policies; Page 2 for evaluation criteria. Yes No X-1 F-] Not Applicable This will extend a gasoline station and provide an improves site Attach additional sheets if necessary Policy 2. Protect and preserve historic and archaeological resources of the Town of Southold. See LWR-P Section III-Policies Pages 3 through 6 for evaluation criteria El Yes [:] No Not Applicable --Gasoline station will not effect historic or archeological resources Attach additional sheets if necessary Policy 3. Enhance visual quality and protect scenic resources throughout the Town of Southold. See LWRP Section M—Policies Pages 6 through 7 for evaluation criteria [_1 Yes F-1 No [XI Not Applicable This use will not impact scenic resources throughout the Town Attach additional sheets if necessary NATURAL COAST POLICIES Policy 4. Minimize loss of fife, structures, and natural resources from flooding and erosion. See LWRP Section 1111—Policies Pages 8 through 16 for evaluation criteria E Yes Ll No LK Not Applicable The filling station will not have any impact upon natural resources Attach additional sheets if necessary Policy 5. Protect and improve water quality and supply in the Town of Southold. See LWRP Section M Policies Pages 16 through 21 for evaluation criterl'11 1:1 E:1 Yes No X Not Applicable The extension of the fillinq station and convenience store will not effect water quality or supply in Southold Attach additional sheets if necessary Policy 6. Protect and restore the quality and function of the Town of Southold ecosystems including Significant Coastal Fish and Wildlife Habitats and wetlands. See LWRP Section H1— Policies; Pages 22 through 32 for evaluation criteria. F-1 Yes I No 1XI Not Applicable This sit is not near Coastal or Wildlife Habitats or Wetlands Attach additional sheets if necessary Policy 7. Protect and improve air quality in the Town of Southold. See LWRP Section M — Policies Pages 32 through 34 for evaluation criteria. 71 Yes F'j No X Not Applicable This coposal will enlarge the are of an existing filling station and not change the impact on air quality Attach additional sheets if necessary Policy 8. Minimize environmental degradation in Town of Southold from solid waste and hazardous substances and wastes. See LWRP Section III—Policies; Pages 34 through 38 for evaluation criteria. 1:1 Yes F-1 No r Not Applicable PUBLIC COAST POLICIES Policy 9. Provide for public access to, and recreational use of, coastal waters, public lands, and public resources of the Town of Southold. See LWRP Section III— Policies; Pages 38 through 46 for evaluation criteria. E:1 Yes No X Not App licable This service has no connection to coastal waters or public lands Attach additional sheets if necessary WORKING COAST POLICIES Policy 10. Protect Southold's water-dependent uses and promote siting of new water-dependent uses in suitable locations. See LWRP Section M—Policies; Pages 47 through 56 for evaluation criteria. F-1 Yes No DX Not App licable The extension of the existing service station has no connection to water dependent uses Attach additional sheets if necessary Policy 11. Promote sustainable use of living marine resources in Long Island Sound, the Peconic Estuary and Town waters. See LWRP Section M—Policies; Pages 57 through 62 for evaluation criteria. Yes 11 No Not Applicable Again there is no relationship to marine resources Attach additional sheets if necessary Policy 12. Protect agricultural lands in the Town of Southold. See LWRP Section M— Policies; Pages 62 through 65 for evaluation criteria. Yes E:1 No 1XI Not Applicable This site.has no impact on agricutural lands_ Attachadditional sheets if necessary Policy 13. Promote appropriate use and development of energy and mineral resources. See LWRP Section M—Policies; Pages 65 through 68 for evaluation criteria, Yes [I No Fx_1 Not App licable The filling station and convenience store will not affect use and development of aD2Zry and mineral resources PREPARED BY DATE 4; TITLE 5 41 V i Amended on 811105 Full Environmental Assessment Form Part I -Project and Setting Instructions for Completing Part I Part 1 is to be completed by the applicant or project sponsor. Responses become part of the application for approval or funding, are subject to public review,and may be subject to further verification. Complete Part I based on information currently available. If additional research or investigation would be needed to fully respond to any item,please answer as thoroughly as possible based on current information; indicate whether missing information does not exist, or is not reasonably available to the sponsor;and,when possible,generally describe work or studies which would be necessary to update or fully develop that information. Applicants/sponsors must complete all items in Sections A&B. In Sections C,D&E,most items contain an initial question that must be answered either"Yes"or"No". If the answer to the initial question is"Yes",complete the sub-questions that follow. If the answer to the initial question is"No",proceed to the next question. Section F allows the project sponsor to identify and attach any additional information. Section G requires the name and signature of the applicant or project sponsor to verify that the information contained in Part I is accurate and complete. A.Project and Applicant/Sponsor Information. Name of Action or Project: Site Plan for Mattituck Gas Station&Convenience Store Project Location(describe,and attach a general location map): 7400 Main Road,(intersection of Old Main Road&Main Road)Mattituck,Town of Southold NY SCTM#1000-122-07-3.2 Brief Description of Proposed Action(include purpose or need): Reconfigure and renovate an existing gas station and convenience store on a 63.357 sf parcel within the General Business zoning use district,located at the intersection of Old Main Road and Main Road. The renovations provide upgraded and expanded fuel dispensary,improved vehicular queing and interior vehicular movement.provide improved landscaping and lighting.The project includes six(6)pump islands with a canopy,a two-story 4,906 sf building consisting of a 1st floor 2,800 sf convenience store with 2nd floor 2,106 sf accessory office. Two ingress and egress points with 30-ft curb cuts are located at the eastbound lane of Main Road(NYS Rt 25). Thirty-four(34)parking stalls including two(2)ADA stalls with twelve(12)stalls landbanked will be provided. The existing double wall fiberglass underground storage tanks will be relocated with the existing freestanding ID/price sign to remain. The existing 1,600 sf building guide rail and minor structures will be removed. A propane cylinder exchange cage,compressed air and vacuum station will be includ ed. Name of Applicant/Sponsor: Telephone:631-312-8852 Emrellgin, Rei-presentative on behalf of AMAC Inc. and 535 Main Realt- LLC E-Mail: sukruilgin@hotmaii.com Y Address:po Box,547 City/PO:Laurel State:NY Zip Code:11948 Project Contact(if not same as sponsor;give name and title/role): Telephone:631-369-8200 Charles R.Cuddy E-Mail:chariescuddy@optonline.net Address: 445 Griffing Avenue City/PO: State: Zip Code: Riverhead NY 11901 Property Owner (if not same as sponsor): Telephone: 631-312-8852 AMAC Inc.&535 Old Main Realty LLC E-Mail: sukruilgin@hotmail.com Address: PO Box 547 City/PO: Laurel State: NY Zip Code:,1948 Page I of 13 FEAF 2019 B.Government Approvals B.Government Approvals,Funding,or Sponsorship. ("Funding"includes grants,loans,tax relief,and any other forms of financial assistance.) Government Entity If Yes: Identify Agency and Approval(s) Application Date Required (Actual or projected) a.City Council,Town Board, E:]Yes[3No or Village Board of Trustees b.City,Town or Village &Z]YesE3Nc) Southold Planning Board Pending Planning Board or Commission c.City,Town or W]Yes[:]No Southold Zoning Board of Appeals Pending Village Zoning Board of Appeals d.Other local agencies OYes[:]No Suffolk County Water Authority public water e.County agencies EUesMNo Suffolk County Department of Health Services -sanitary disposal f.Regional agencies []Yes[Z]No g.State agencies [Z]YesE:INO NYSDOT curb cuts h.Federal agencies Elyes[ZINO i. Coastal Resources. i. Is the project site within a Coastal Area,or the waterfront area of a Designated Inland Waterway? E]Yes ONo ii. Is the project site located in a community with an approved Local Waterfront Revitalization Program? 0 YesElNo iii. Is the project site within a Coastal Erosion Hazard Area? M Yes[Z]No C.Planning and Zoning C.1.Planning and zoning actions. Will administrative or legislative adoption,or amendment of a plan,local law,ordinance,rule or regulation be the 0Yes0No only approval(s)which must be granted to enable the proposed action to proceed? • If Yes,complete sections C,F and G. • If No,proceed to question C.2 and complete all remaining sections and questions in Part I C.2.Adopted land use plans. a.Do any municipally-adopted (city,town,village or county)comprehensive land use plan(s)include the site [Z]Yes[:]No where the proposed action would be located? If Yes,does the comprehensive plan include specific recommendations for the site where the proposed action WlYesEDNo would be located? b.Is the site of the proposed action within any local or regional special planning district(for example:Greenway; OYesONo Brownfield Opportunity Area(BOA);designated State or Federal heritage area;watershed management plan; or other?) If Yes,identify the plan(s): c. Is the proposed action located wholly or partially within an area listed in an adopted municipal open space plan, [:]YesoNo or an adopted municipal farmland protection plan? If Yes,identify the plan(s): Page 2 of 13 C.3. Zoning a. Is the site of the proposed action located in a municipality with an adopted zoning law or ordinance. O Yes❑No If Yes,what is the zoning classification(s)including any applicable overlay district? General Business b. Is the use permitted or allowed by a special or conditional use permit? ®Yes[]No c.Is a zoning change requested as part of the proposed action? ❑Yes®No If Yes, i. what is the proposed new zoning for the site? CA.Existing community services. a.In what school district is the project site located? _ Mattituck-Cutchogue school District b.what police or other public protection forces serve the project site? Southold Town Police c.which fire protection and emergency medical services serve the project site? Mattituck Fire Department _ d.What parks serve the project site? Mattituck Park District D.Project Details D.I.Proposed and Potential Development a.what is the general nature of the proposed action(e.g.,residential,industrial,commercial,recreational; if mixed, include all components)? Commercial-renovation and expansion of an existing gas station b.a.Total acreage of the site of the proposed action? 1.454 acres b.Total acreage to be physically disturbed? 1.454 acres c.Total acreage(project site and any contiguous properties)owned or controlled by the applicant or project sponsor? 1.454 acres c.Is the proposed action an expansion of an existing project or use? 0 Yes❑No i. If Yes,what is the approximate percentage of the proposed expansion and identify the units(e.g.,acres,miles,housing units, square feet)? % _ _ 15% Units: fuel pumps and store area d.Is the proposed action a subdivision,or does it include a subdivision? ❑Yes ONo If Yes, i. Purpose or type of subdivision?(e.g.,residential, industrial,commercial;if mixed,specify types) ii. Is a cluster/conservation layout proposed? ❑Yes❑No ii i.Number of lots proposed? iv. Minimum and maximum proposed lot sizes? Minimum - Maximum _ e.will the proposed action be constructed in multiple phases? ❑Yes®No i. If No,anticipated period of construction: _ 6 months ii. If Yes: • Total number of phases anticipated • Anticipated commencement date of phase 1 (including demolition) month year • Anticipated completion date of final phase month ____year • Generally describe connections or relationships among phases,including any contingencies where progress of one phase may determine timing or duration of future phases: Page 3 of 13 f.Does the project include new residential uses? ❑Yes®No If Yes,show numbers of units proposed. One Fa__mi 1Y Two Fami 1 Three Fami ly Multi le Fami 1y four or more Initial Phase At completion of all phases _ g.Does the proposed action include new non-residential construction(including expansions)? ®Yes❑No If Yes, i.Total number of structures 1 ii. Dimensions(in feet)of largest proposed structure: 35 height; width; and length iii. Approximate extent of building space to be heated or cooled: 5,000 square feet h.Does the proposed action include construction or other activities that will result in the impoundment of any ❑Yes®No liquids,such as creation of a water supply,reservoir,pond,lake,waste lagoon or other storage? If Yes, i. Purpose of the impoundment: ii. If a water impoundment,the principal source of the water: El Ground water El Surface water streams❑Other specify: hi. If other than water, identify the type of impounded/contained liquids and their source. iv. Approximate size of the proposed impoundment. Volume: million gallons;surface area: _ acres v. Dimensions of the proposed dam or impounding structure: height; length vi. Construction method/materials for the proposed dam or impounding structure(e.g.,earth fill,rock,wood,concrete): D.2. Project operations a.Does the proposed action include any excavation,mining,or dredging,during construction,operations,or both? [:]Yes6dNo (Not including general site preparation,grading or installation of utilities or foundations where all excavated materials will remain on site) If Yes: i.What is the purpose of the excavation or dredging? H. How much material(including rock,earth,sediments,etc.)is proposed to be removed from the site? • Volume(specify tons or cubic yards):_ • Over what duration of time? iii. Describe nature and characteristics of materials to be excavated or dredged,and plans to use,manage or dispose of them. iv. Will there be onsite dewatering or processing of excavated materials? [:]Yes[]No If yes,describe. v. What is the total area to be dredged or excavated? acres vi. What is the maximum area to be worked at any one time? acres vii. What would be the maximum depth of excavation or dredging? feet viii. Will the excavation require blasting? [-]Yes[:]No ix. Summarize site reclamation goals and plan: b.Would the proposed action cause or result in alteration of,increase or decrease in size of,or encroachment [:]YesR]No into any existing wetland,waterbody,shoreline,beach or adjacent area? If Yes: i. Identify the wetland or waterbody which would be affected(by name,water index number,wetland map number or geographic description): Page 4 of 13 .6 h. Describe how the proposed action would affect that waterbody or wetland,e.g.excavation,fill,placement of structures,or alteration of channels,banks and shorelines. Indicate extent of activities,alterations and additions in square feet or acres: iii.Will the proposed action cause or result in disturbance to bottom sediments? [DYes[:]No If Yes,describe: i.v. Will the proposed action cause or result in the destruction or removal of aquatic vegetation? E]Yeso No If Yes: 0 acres of aquatic vegetation proposed to be removed: 0 expected acreage of aquatic vegetation remaining after project completion: 0 purpose of proposed removal(e.g.beach clearing,invasive species control,boat access): a proposed method of plant removal: 9 if chemical/herbicide treatment will be used,specify product(s): v. Describe any proposed reclamation/mitigation following disturbance: c.Will the proposed action use,or create a new demand for water? W]Yes L]No If Yes: i. Total anticipated water usage/demand per day- aDDrox 400_gallons/day ii. Will the proposed action obtain water from an existing public water supply? Oyes E]No If Yes: 0 Name of district or service area: Suffolk County Water Authority 0 Does the existing public water supply have capacity to serve the proposal? 0 Yes[]No a Is the project site in the existing district? W1 Yes[:]No 0 Is expansion of the district needed? El Yes®No 0 Do existing lines serve the project site? ®Yes[]No iii. Will line extension within an existing district be necessary to supply the project? E]Yes ONo If Yes: 0 Describe extensions or capacity expansions proposed to serve this project: 0 Source(s)of supply for the district: iv. Is a new water supply district or service area proposed to be formed to serve the project site? El YesVINo If,Yes: * Applicant/sponsor for new district: * Date application submitted or anticipated: * Proposed source(s)of supply for new district: V. If a public water supply will not be used,describe plans to provide water supply for the project: vi.If water supply will be from wells(public or private),what is the maximum pumping capacity: gallons/minute. d.Will the proposed action generate liquid wastes? ®Yes L]No If Yes: i. Total anticipated liquid waste generation per day: 300 gallons/day H.Nature of liquid wastes to be generated(e.g.,sanitary wastewater, industrial;if combination,describe all components and approximate volumes or proportions of each): Sanitary Wastewater on site disposal per DCDOH design requirements W. Will the proposed action use any existing public wastewater treatment facilities? ❑Yes[Z]No If Yes: 6 Name of wastewater treatment plant to be used: a Name of district: 0 Does the existing wastewater treatment plant have capacity to serve the project? ❑Yes[3No 0 Is the project site in the existing district? E]YesL]No 0 Is expansion of the district needed? F1 Yes ONo Page 5 of 13 & Do existing sewer lines serve the project site? []YesoNo 9 Will a line extension within an existing district be necessary to serve the project? F]Yes[]No If Yes: Describe extensions or capacity expansions proposed to serve this project: iv. Will a new wastewater(sewage)treatment district be formed to serve the project site? 0Yes0No If Yes: • Applicant/sponsor for new district: • Date application submitted or anticipated: • What is the receiving water for the wastewater discharge? v. If public facilities will not be used,describe plans to provide wastewater treatment for the project,including specifying proposed receiving water(name and classification if surface discharge or describe subsurface disposal plans): vi. Describe any plans or designs to capture,recycle or reuse liquid waste: e.Will the proposed action disturb more than one acre and create stormwater runoff,either from new point OYes[:]No sources(i.e.ditches,pipes,swales,curbs,gutters or other concentrated flows of stormwater)or non-point source(i.e.sheet flow)during construction or post construction? If Yes: i. How much impervious surface will the project create in relation to total size of project parcel? Square feet or 1.2 acres(impervious surface) Square feet or acre ' rcel size) ii. Describe types of new point sources. — AdPdilltional pavement,larger canopy&building roofs. .'* - - - -- - -- I M. Where will the stormwater runoff be directed(i.e.on-site stormwater management facility/structures,adjacent properties, groundwater,on-site surface water or off-site surface waters)? On-site storm water infiltration structures • If to surface waters,identify receiving water bodies or wetlands: • Will stormwater runoff flow to adjacent properties? ElYesONo iv. Does the proposed plan minimize impervious surfaces,use pervious materials or collect and re-use stormwater? OYesE]No f. Does the proposed action include,or will it use on-site,one or more sources of air emissions,including fuel [:]YesWlNo combustion,,waste incineration,or other processes or operations? If Yes,identify: i.Mobile sources during project operations(e.g.,heavy equipment,fleet or delivery vehicles) h. Stationary sources during construction(e.g.,power generation,,structural heating,batch plant,crushers) iii. Stationary sources during operations(e.g.,process emissions,large boilers,electric generation) g.Will any air emission sources named in D.2.f(above),require a NY State Air Registration,Air Facility Permit, E1Yes0No or Federal Clean Air Act Title IV or Title V Pen-nit? If Yes: i. Is the project site located in an Air quality non-attainment area? (Area routinely or periodically fails to meet E]Yes EIN o ambient air quality standards for all or some parts of the year) ii. In addition to emissions as calculated in the application,the project will generate: Tons/year(short tons)of Carbon Dioxide(CO2) • Tons/year(short tons)of Nitrous Oxide(N20) 0 Tons/year(short tons)of Perfluorocarbons(PFCs) • Tons/year(short tons)of Sulfur Hexafluoride(SF6) • Tons/year(short tons)of Carbon Dioxide equivalent of Hydroflourocarbons(HFCs) Tons/year(short tons)of Hazardous Air Pollutants(HAPs) Page 6 of 13 h. Will the proposed action generate or emit methane(including,but not limited to,sewage treatment plants, []YesoNo landfills,composting facilities)? If Yes: i. Estimate methane generation in tons/year(metric): ii.Describe any methane capture,control or elimination measures included in project design(e.g.,combustion to generate heat or electricity,flaring): L Will the proposed action result in the release of air pollutants from open-air operations or processes,such as []YesoNo quarry or landfill operations? If Yes:Describe operations and nature of emissions(e.g.,diesel exhaust,rock particulates/dust): j.Will the proposed action result in a substantial increase in traffic above present levels or generate substantial ❑YesoNo new demand for transportation facilities or services? If Yes: i. When is the peak traffic expected(Check all that apply): ❑Morning ❑Evening []Weekend ❑Randomly between hours of to ii. For commercial activities only,projected number of truck trips/day and type(e.g.,semi trailers and dump trucks): iii. Parking spaces: Existing 4 Proposed 29 Net increase/decrease _ 25 iv.Does the proposed action include any shared use parking? ElyesONO v. If the proposed action includes any modification of existing roads,creation of new roads or change in existing access,describe: vi. Are public/private transportation service(s)or facilities available within 1/2 mile of the proposed site? OYes[:]No vii Will the proposed action include access to public transportation or accommodations for use of hybrid,electric [:]Yesg]No or other alternative fueled vehicles? viii.Will the proposed action include plans for pedestrian or bicycle accommodations for connections to existing E]Yesg]No pedestrian or bicycle routes? k.Will the proposed action(for commercial or industrial projects only)generate new or additional demand ❑Yes❑No for energy? If Yes: i. Estimate annual electricity demand during operation of the proposed action. ii. Anticipated sources/suppliers of electricity for the project(e.g.,on-site combustion,on-site renewable,via grid/local utility,or other): iii. Will the proposed action require a new,or an upgrade,to an existing substation? [:]Yes[:]No 1.Hours of operation. Answer all items which apply. i. During Construction: ii. During Operations: • Monday-Friday: 7:00 am to 4:30 pm & Monday-Friday: 6:00 am to 8:00 pm • Saturday: 8:00 am to 3:00 pm • Saturday: 6:00 am to 8:00 pm * Sunday: & Sunday: 6:00 am to 8:00 pm * Holidays: * Holidays: _ 6:00 am to 8:00 pm Page 7 of 13 m.Will the proposed action produce noise that will exceed existing ambient noise levels during construction,, El Yes 0 No operation,or both? If yes: i. Provide details including sources,time of day and duration: ii. Will the proposed action remove existing natural barriers that could act as a noise barrier or screen? 0 Yes ONo Describe: n.Will the proposed action have outdoor lighting? 0 Yes E]No If yes: i. Describe source(s),location(s),height of fixture(s),direction/aim,and proximity to nearest occupied structures: ii. Will proposed action remove existing natural barriers that could act as a light barrier or screen? 0 Yes IZ]No Describe: o. Does the proposed action have the potential to produce odors for more than one hour per day? D Yes ONo If Yes,describe possible sources,potential frequency and duration of odor emissions,and proximity to nearest occupied structures: p.Will the proposed action include any bulk storage of petroleum(combined capacity of over ],100 gallons) V3 Yes ONo or chemical products 185 gallons in above ground storage or any amount in underground storage? If Yes: i. Product(s)to be stored UST#1-15,000 gal.reg gasoline,#2-split-8,000 gal reg 7,000 gal.super gas A,BT 1000-gal kerosene 275 gal heating oil ii. Volume(s) per unit time (e.g.,month,year) iii. Generally,describe the proposed storage facilities: q. Will the proposed action(commercial, industrial and recreational projects only)use pesticides(i.e.,herbicides, 0 Yes ONo insecticides)during construction or operation? If Yes: i. Describe proposed treatment(s): ii. Will the proposed action use Inte rated Pest Management Practices? ❑ Yes El\1 0 r.Will the proposed action(commercial or industrial projects only)involve or require the management or disposal 0 Yes []No of solid waste(excluding hazardous materials)? If Yes: i. Describe any solid waste(s)to be generated during construction or operation of the facility: • Construction: 500 tons per day for two days_(unit of time) • Operation: 25 tons per week (unit of time) ii. Describe any proposals for on-site minimization,recycling or reuse of materials to avoid disposal as solid waste: * Construction:demolition debris will be sorted for recy LIng of metals,concrete and asphalt * Operation: Bottles,cans will be recycled inspecific_bins. Paper and cardboard will be source separated. W. Proposed disposal methods/facilities for solid waste generated on-site: 0 Construction:NYSDEC a,pproyed facility TBD by construction contractor a Operation- NYSDEC approved hauler and facility TBD by owner Page 8 of 13 s.Does the proposed action include construction or modification of a solid waste management facility? ❑Yes V] No If Yes: i. Type of management or handling of waste proposed for the site(e.g.,recycling or transfer station,composting,)andf ll,or other disposal activities): ii. Anticipatcd rate of disposal/processing: • Tons/month,if transfer or other non-combustion/thermal treatment,or • Tons/hour,if combustion or thermal treatment in. If landfill,anticipated site life: years t.will the proposed action at the site involve the commercial generation,treatment,storage,or disposal of hazardous[]Yes W]No waste? If Yes: i.Name(s)of all hazardous wastes or constituents to be generated,handled or managed at facility: ii. Generally describe processes or activities involving hazardous wastes or constituents: iii. Specify amount to be handled or generated _tons/month iv. Describe any proposals for on-site minimization,recycling or reuse of hazardous constituents: v. Will any hazardous wastes be disposed at an existing offsite hazardous waste facility? Yes No If Yes:provide name and location of facility: If No: describe proposed management of any hazardous wastes which will not be sent to a hazardous waste facility: E.Site and Setting of Proposed Action E.1.Land uses on and surrounding the project site a.Existing land uses. i. Check all uses that occur on,adjoining and near the project site. ❑ Urban ❑ Industrial ® Commercial ❑ Residential(suburban) ❑ Rural(non-farm) ❑ Forest ❑ Agriculture ❑ Aquatic ❑ other(specify): ii. If mix of uses,generally describe: b.Land uses and covertypes on the project site. Land use or Current Acreage After Change Covertype Acreage Project Completion (Acres+/-) • Roads,buildings,and other paved or impervious 1.2 0.835 ac 0.365 surfaces • Forested .25 0.61 ac .36 • Meadows,grasslands or brushlands(non- 0 0 agricultural,including abandoned agricultural) • Agricultural 0 0 (includes active orchards,field,greenhouse etc.) • Surface water features 0 0 (lakes,ponds,streams,rivers,etc.) • Wetlands(freshwater or tidal) 0 0 • Non-vegetated(bare rock,earth or fill) 0 0 • other Describe: 0 0 Page 9 of 13 c.Is the project site presently used by members of the community for public recreation? ❑YesONo i. If Yes:explain: d.Are there any facilities serving children,the elderly,people with disabilities(e.g.,schools,hospitals,licensed ❑Yes®No day care centers,or group homes)within 1500 feet of the project site? If Yes, i. Identify Facilities: e.Does the project site contain an existing dam? ❑Yes®No If Yes: i. Dimensions of the dam and impoundment: • Dam height: feet Dam length: feet • Surface area: acres 0 Volume impounded: gallons OR acre-feet ii. Dam's existing hazard classification: iii. Provide date and summarize results of last inspection: f.Has the project site ever been used as a municipal,commercial or industrial solid waste management facility, ❑Yes®No or does the project site adjoin property which is now,or was at one time,used as a solid waste management facility? If Yes: i. Has the facility been formally closed? ❑Yes❑No 0 If yes,cite sources/documentation: ii. Describe the location of the project site relative to the boundaries of the solid waste management facility; iii. Describe any development constraints due to the prior solid waste activities: g.Have hazardous wastes been generated,treated and/or disposed of at the site,or does the project site adjoin ❑Yes®No property which is now or was at one time used to commercially treat,store and/or dispose of hazardous waste? If Yes: i. Describe waste(s)handled and waste management activities,including approximate time when activities occurred: h. Potential contamination history. Has there been a reported spill at the proposed project site,or have any ❑Yes®No remedial actions been conducted at or adjacent to the proposed site? If Yes: i. Is any portion of the site listed on the NYSDEC Spills Incidents database or Environmental Site ❑Yes❑No Remediation database? Check all that apply: ❑ Yes—Spills Incidents database Provide DEC ID number(s): ❑ Yes--Environmental Site Remediation database Provide DEC ID number(s): ❑ Neither database ii. If site has been subject of RCRA corrective activities,describe control measures: _ iii. Is the project within 2000 feet of any site in the NYSDEC Environmental Site Remediation database? ❑Yes❑No If yes,provide DEC ID number(s): iv. If yes to(i),(ii)or(iii)above,describe current status of site(s): 9925065-Spill closed 6/28/99;0325006-Spill closed 412103;0550760-Spill closed 10/19/10 Page 10 of 13 v. Is the project site subject to an institutional control limiting property uses? []Yesg]No If yes,DEC site ID number: • Describe the type of institutional control(e.g.,deed restriction or easement): • Describe any use limitations: • Describe any engineering controls: • Will the project affect the institutional or engineering controls in place? ❑Yes❑No • Explain: E.2. Natural Resources On or Near Project Site a.What is the average depth to bedrock on the project site? 850 feet b.Are there bedrock outcroppings on the project site? ❑Yes®No If Yes,what proportion of the site is comprised of bedrock outcroppings? % c.Predominant soil type(s)present on project site: manmade-paved 100 1 % d.What is the average depth to the water table on the project site? Average: +/-20 feet e.Drainage status of project site soils: Well Drained: 100%of site ❑ Moderately Well Drained: %of site ❑ Poorly Drained %of site f.Approximate proportion of proposed action site with slopes: ® 0-10%: 100 %of site ❑ 10-15%: %of site ❑ 15%or greater: %of site g.Are there any unique geologic features on the project site? ❑Yes❑No If Yes,describe- h.Surface water features. i. Does any portion of the project site contain wetlands or other waterbodies(including streams,rivers, ❑Yes0No ponds or lakes)? ii. Do any wetlands or other waterbodies adjoin the project site? ❑YesONo If Yes to either i or ii,continue. If No,skip to E.2.i. X. Are any of the wetlands or waterbodies within or adjoining the project site regulated by any federal, El Yes®No state or local agency? iv. For each identified regulated wetland and waterbody on the project site,provide the following information: r Streams: Name Classification ` Lakes or Ponds: Name Classification Wetlands: Name Approximate Size " Wetland No.of regulated by DEC) v. Are any of the above water bodies listed in the most recent compilation of NYS water quality-impaired El Yes❑No waterbodies? If yes,name of impaired water body/bodies and basis for listing as impaired: i.Is the project site in a designated Floodway? []Yes g]No j.Is the project site in the 1.00-year Floodplain? ❑Yes®No k. Is the project site in the 500-year Floodplain? ❑Yes oNo 1.Is the project site located over,or immediately adjoining,a primary,principal or sole source aquifer? ®Yes❑No If Yes: i.Name of aquifer: Long Island upper glacial and Loyd Page 11 of 13 m. Identify the predominant wildlife species that occupy or use the project site: _ NIA n.Does the,project site contain a designated significant natural community? ❑Yes ONo If Yes: i. Describe the habitat/community(composition,function,and basis for designation): ii. SOUrce(s)of description or evaluation: - iii. Extent of community habitat: • Currently: acres • Following completion of project as proposed: acres • Gain or loss(indicate+or-): c acres o.Does project site contain any species of plant or animal that is listed by the federal government or NYS as ❑YesWJNo endangered or threatened,or does it contain any areas identified as habitat for an endangered or threatened species? If Yes: i. Species and listing(endangered or threatened): p. Does the project site contain any species of plant or animal that is listed by NYS as rare,or as a species of ❑Yes[Z]No special concern? If Yes: i. Species and listing: q.Is the project site or adjoining area currently used for hunting,trapping,fishing or shell fishing? ❑YesoNo If yes,give a brief description of how the proposed action may affect that use: _ E.3. Designated Public Resources On or Near Project Site a. Is the project site,or any portion of it,located in a designated agricultural district certified pursuant to ❑Yes®No Agriculture and Markets Law,Article 25-AA, Section 303 and 304? If Yes, provide county plus district name/number: b.Are agricultural lands consisting of highly productive soils present? ❑Yes®No i. If Yes:acreage(s)on project site? ii. Source(s)of soil rating(s): c. Does the project site contain all or part of,or is it substantially contiguous to,a registered National ❑YesoNo Natural Landmark? If Yes: i. Nature of the natural landmark: ❑Biological Community ❑ Geological Feature ii. Provide brief description of landmark,including values behind designation and approximate size/extent: d.Is the project site located in or does it adjoin a state listed Critical Environmental Area? ❑Yes0No If Yes: i. CEA name: H. Basis for designation: iii. Designating agency and date: Page 12 of 13 e. Does the project site contain,or is it substantially contiguous to,a building,archaeological site,or district El Yes®No which is listed on the National or State Register of Historic Places,or that has been determined by the Commissioner of the NYS Office of Parks,Recreation and Historic Preservation to be eligible for listing on the State Register of Historic Places? If Yes: L Nature of histori c/archaeo logical resource: El Archaeological Site E]Historic Building or District ii.Name: iii. Brief description of attributes on which listing is based: f Is the project site,or any portion of it located in or adjacent to an area designated as sensitive for FlYesoNo archaeological sites on the NY State Historic Preservation Off-ice(SHPO)archaeological site inventory? g.Have additional archaeological or historic site(s)or resources been identified on the project site? E]Yesg]No If Yes: i.Describe possible resource(s): ii. Basis for identification: h.Is the project site within fives miles of any officially designated and publicly accessible federal,state,or local OYes[]No scenic or aesthetic resource? If Yes: L Identify resource: NYS Rt 25 is a Scenic Byway ii. Nature of,or basis for,designation(e.g.,established highway overlook,state or local park,state historic trail or scenic byway, etc.): The site is located on a Scenic Byway iiL Distance between project and resource: 0.0 miles. i. Is the project site located within a designated river corridor under the Wild,Scenic and Recreational Rivers ❑Yes W]No Program 6 NYCRR 666? If Yes: L Identify the name of the river and its designation: ii. Is the activity consistent with development restrictions contained in 6NYCRR Part 666? []Yes®No -J F.Additional Information Attach any additional information which may be needed to clarify your project. If you have identified any adverse impacts which could be associated with your proposal,please describe those impacts plus any measures which you propose to avoid or minimize them. G. Verification I certify that the information provided is true to the best of my knowledge. AMAC Inc. and Applicant/Sponsor Name 535 Main Realty LLC Date Signature Title PRINT FORM Page 13 of 13 PACC ENVIRONMENTAL ENGINEERING xCONSULTING September 2. 2O25 Town of Southold Planning Board Town Hall Annex 54375StaYe Route25 8outho|d, New York 11871 Re: Proposed yMatt|tcckGas Station and Convenience Store Positive Declaration and Revised Plan 7400 Main Road, Mattituch' Suffolk County, NY Chairman Rich and Members of the Planning Board: This firm is serving as planning and environmental consultant to the applicant, Mattituck Gas Station. This correspondence is to address the Positive Declaration issued by the Town of Southold Planning Board on July 9. 2024 (July 2024 Positive Dmo|onaUon)' and the submission of revised plan to address the major components of the proposed project. The proposed action subject to the July 2024 Positive Declaration includes the merging of two tax lots (1000-122-07-1 and 3.2) and site improvements for the purpose of improving the function and aesthetics of the existing gas station and convenience store. The improvements include: (1) the demolition of the existing one-story, 1.500 square foot (SF) convenience store from the east end of the penoe| and construction of new two-story, 5.000 8F convenience store on the south end of the parcel (the second floor of2.1DO square feet is to be the owner's office); (2) the repositioning of the pump islands from two parallel islands to a single bay with six pump stations (12fue| pumps)and overhead canopy of 152feat(ft) in length and 24 ft in width; (3) installation of 19 parking stalls (including 2 ADA stalls) in front of the convenience store and 15 |andbonked eba||a (fora total of34 oto||a); (4) installation of plantings along the site frontages; and (5) installation of curbing with formalized access points on Main Road (two aooeao points) and [>|d Main Rood (one ecoeao point), resulting in improved on-site circulation for delivery trucks and vehicles. The existing gas station onthe subject parcel has been in operation for more than 8Oyears. The subject property is 1.39 acres and within the General Business(B)Zoning District.The local approvals required for the proposed action include site plan approval from the Planning Boord, and the following approvals from the Zoning Board of Appeals (ZBA): special exception permit (for gasoline service station) (§280'48[B][12]); and, area variances for(1) minimum front yard setback (§280-50A) (Required: 100 feet; Proposed: 10 ft[Convenience Store to Old Main Road], 45.6 ft[Canopy to Main Road], and 60.8 ft[Canopy to C}|d Main Road]); (2) maximum structure frontage (§280-50C) (Permitted: GU ft; Proposed: 62.6 ft convenience store and 152 ft canopy); and (3) minimum structure setback from right-of-way (§280-50C) (Required: 75 ft.; Proposed: 45.8 ft [Canopy to Main Rood]. 10 ft [Convenience Store to Old Main Road] and 8O.1ft [Canopy to Old Main Road]). Review of the application file indicates on initial site plan application with Full Environmental Assessment Form (EAF) in November2O21. submission of traffic study and EAF narrative in May 2022. submission of erchiteoturaK3D photo-simulations in September 2022. several staff raportn, and a site plan completeness determination in April 2024. Coordinated review was initiated by the Planning Board in May 2024 and the aforementioned Positive Declaration was issued in July 2024. The Positive Declaration included the following four (4) impact issues as requiring further analysis in a Draft Environmental Impact Statement(OB8): 1. Aesthetic Resources 2. Noiea, Odor and Light(only Lighting Impacts Identified) 3. Consistency with Community Plans 4. Consistency with Community Character P.W. GROSSER CONSULTING ENGINEER & HYDROGEOLOGIST, D.P.C. Page 1 oonsM/A ° MAwnxrTxm e SAnAroGA Srn/wGs " MomrIcsLLo ^ svxAcusE P' AAGC ENVIRONMENTAL ENGINEERING ummumm Based on the narrative descriptions of the potential impacts to aesthetic resources and community character, and lighting impacts from the proposed canopy, the issues largely arise from the parcel location and triangular configuration, which results in a highly visible parcel along Main Road. A DBB evaluation and process cannot remedy the triangular configuration of the lots, which is resulting in the need for front yard setback variances as well as the increased visibility of the site with the |ot'm hypotenuse along Main Road. With a lot frontage ofG15±feet along Main Road, e maximum lot depth of65.B feet, and Old Main Road bordering the southern parcel boundary, any redevelopment would require e front yard setback. In faot, the existing gas station convenience store does not meet the front yard setback requirement. Also, with o maximum lot depth of 558 feet, the placement of e smaller canopy or canopies perpendicular to Main Road with adequate drive aisles is possible but cannot meet the front yard setback requirement. Also, the impacts to aesthetic resources and community character are identified as potentially significant and adverse; however, seems to ignore the existing viewshed today. Based on the photo simulations of how the site will change upon implementation of the proposed plan, the proposed action clearly improves the view from Main Road.The proposed architecture of the new convenience store is of residential feel and compliments the buildings on the north side of Main Road.Also,the proposed site improvements to curbing, formalized eoomss. and |endacaping, replaces e site devoid of all such features. It is not understood hmw, when comparing to the existing condition to what is proposed, there can be a determination of potential significant adverse visual impacts. Regarding lighting, the Positive Declaration indicates that impacts are likely even if compliance with Town Code is achieved. From the applications already approved by the Planning Boord, including the Southold Gas Station and Convenience Store, it is well documented that lighting design can be modified to eliminate adverse impacts. A lengthy DEIS process is not necessary for desired lighting modifications to be made. Regarding the consistency with Community Plans, the Town Code permits the convenience store in the General Business(B)zoning district with a gas station outside the Hamlet Center. The Positive Declaration states that the ^proposed new construction convenience store portion and appurtenant build-out of the action is likely to result in a large conflict with the community's current plans or goals as specified in the Southold Town Comprehensive Plan (2020)` resulting in potential moderate to large adverse impacts on aesthetics,economics and growth patterns in Mattituck...Southold Town has defined a new direction based on community input to prevent sprawl and direct retail uses within or near the Hamlet Centers. The lot is not located within the Hamlet Center or HALO." (p 3). VVh||e it is recognized that the Plan is the vision, the Town did not implement zoning changes after the adoption of the 2020 Comprehensive Plan. Accordingly, the zoning regulations permit the current use that will continue to exist but in an improved form. Furthermore.the Positive Declaration ignores the fact that e gas station with convenience store has existed on the property for over 60 years. The DEIS evaluation and process will not modify the purpose and intent of the proposed aotion, which is to modernize the existing gas mtetion, improve the functionality of an existing buoinmeo, and to replace the existing complimentary and customary convenience store use tna gas station use. Nqoreover, the replacement ofa one-story, 1.500 8F convenience store with a two-story, 51000 SF convenience store with the entire second floor (2,1100 SF or 42% of the building) to be used for the owner's office is not nstoi| sprawl. The utilization of the second floor as an owner's office has been communicated to the Town in documentation including the Traffic Assessment prepared by Dunn Associates. The narrative elaboration on the inconsistency with the 2020 Comprehensive Plan further states that to convenience store's relocation and expansion could n*au|t in retail sprawl." The project relocates the convenience store from the east side to the south side of the same triangular lot on Main Road and proposes to expand the store by 1.400 SF (from 1'500 SF to 2.900 BF, as the remaining 2.100 SF constitutes the second-floor owners office). Notwithstanding the fact that the use is permitted under the Town's zoning oode. itiauno|earhovvthimreioccdionandexpansionontheoameproperty^cou|dresultinretai| sprawi.^ lt) PACC ENVIRONMENTAL ENGINEERING xmNSuoNG Based on the application record, including the July 2024 Positive Declaration, it appears that the decision to move directly toeDBGfails to consider myriad factual items including: (1) The use to be improved (ie, gas station with convenience store) currently exists without any incident orissues. (2) The existing nonconforming front yard setback and the triangular configuration of the merged lot makes it physically impossible to meet the front yard setback requirement for any building of usable size. (3) The photo-simulations of the proposed project demonstrate an architectural design that is compatible and complimentary tothe surrounding land ueeo, including the overhead canopy that serves eea weather barrier for the convenience ofpatrons. (4) The proposed improvements to landscaping and access/circulation results in an improvement to an existing gas station and convenience store use that seeks to continue but, in a form, and layout that improves the functionality and aesthetics. (5) The Town Zoning Code permits the convenience store in the General Business (B) zoning district with agaa station outside the Hamlet Center. (G) The Town did not implement any zoning changes after the adoption of the 2020 Comprehensive Plan.Accordingly,while it is recognized that the Plan is the vision, the zoning regulations permit the current use that will continue to exist but in an improved form. (7) As the gas station with convenience store use has existed and operated for over 60 years on this property, the improvements to such uses should not be considered retail sprawl. (B) The convenience store exists in a smaller form and the improvements to same results in an elimination of additional vehicular trips for the goods and products that are customarily bought by gas station patrons and provides a formal office area on the second floor for the business owners. FinaUy, in the absence of a public hearing after the site plan application was deemed comp|ate, it is respectfully submitted that a critical step was eliminated. Moving directly to e lengthy DE|8 process without allowing the applicant to present its plan or receipt of any public comments only delays consideration of the application and desired actions of the applicant for an improved business. Revised Plan In response tothe Positive Declaration and a desire to improve the existing business in o timely manner. the applicant has elected to revise the proposed site design("prior plan")to address the major components of the project. As indicated on the revised site plan, the new design addresses the overhead canopy and the location of the convenience store. Specifically, the overhead canopy has been modified from 152 ft L x 24 ft W to 82 ftLxGOftVV and has been repositioned from the original parallel placement toPWein Road toaperpendicular placement. The result of same reduces the structure frontage Main along �(n Road from 152 ftto 50ft. The proposed improved convenience store has been maintained in the current location on the east side of the property and h as been red uced i n size from 5,000 S F to 4,906 SF (with th e secon d floor to be used entirely for the owner's office). Other components of the plan are the same as previously proposed; hovvever, the number of|andbanked stalls has been reduced from 15to12. t) PACC RmRONMENmL ENGINEERING xCONSULTING Asummary of the prior plan and the revised site plan follows in the table below. Prior Plan —FRevised Site Plan Plan Description Canopy 152 ft L x 24 ft W— positioned parallel to 84 ft L x 50 ft W—positioned perpendicular Main Road(152 ft along road frontage) to Main Road(50 ft along road frontage) Convenience Store 5,000 SF relocated from east side to 4,906 SF to remain in current location southern portion of site Pump Islands Single bay with 6 pump stations Double bay with 6 pump stations On-Site Parking 34 stalls(incl.2 ADA and 15 landbanked) 34 stalls(incl.2 ADA and 12 landbanked) (Required: 53 stalls) Area Variances F ro nt Ya rd Setba ck 10 ft-Convenience Store to Old Main Rd 25 ft-Convenience Store to Old Main Rd (100 ft Req u i red) 60.8 ft-Canopy to Old Main Rd 61.3 ft—Canopy to Old Main Rd Max. Structure 62.5 ft-Convenience Store 48 ft-Convenience Store Min. Structure Setback 45.8 ft-Canopy to Main Rd 25 ft-Canopy to Main Rd from Right-of-Way 10 ft-Convenience Store to Old Main Rd 35.1 ft-Convenience Store to Old Main Rd (§280-50C) 60.1 ft-Canopy to Old Main Rd 61.3 ft-Canopy to Old Main Rd Given the filing of the revised plan with the Planning Board and the Zoning Board of Appeals, it is requested that the Planning Board rescind the July 2024Positive Declaration. Of importance is the input of the ZBA. Based on the application mabahe|s and files published on the Town'owmboite` it does not appear the Planning Board received any comments during coordinated review from the ZBA; however, the bnpeo issues identified in the July 2024 positive Declaration were directly related to the use and relief required from the ZBA. Thank you for your consideration. Roepectfu||y, P.W. Grosser Consulting It Kim Gmnnoro-Oanoea. Nl.B.`A|CPCEP Vice President cc Char|eeR. Cuddy. Esq. OFFICE LOCATION: r, MAILING ADDRESS Town Hall Annex P.O. Box 1179 Route 25 Southold NY 11971 54 375 State r , (cor.Main Rd. &Youngs Ave.) Telephone: 631-765-1938 Southold,NY + www.southoldtownny.gov r.+e PLANNING BOARD OFFICE TOWN OF SOUTHOLD MEMORANDUM To: Accounting From: Planning Department Date: December 23, 2025 Re: Check Please deposit the attached check into B691: Deferred Revenue. Fee is for a Site Plan Application not yet accepted by the Planning Board. A licant/Project Name & Type Tax Map # Amount Check Date/No. PP J Mattituck Gas Station & Convenience 11/20/2025 - Store Site Plan 122.-7-1 & 3.2 $550.00 #2274 Charles Cuddy CEW Att. BULK REQUIREMENTS GENERAL NOTES / 1. ZONE: GENERAL BUSINESS (8) DISTRICT 1. PROPERTY OWNER/ APPLICANT: HIGH err E0 2. USE: AMAC INC. & 535 OLD MAIN REALTY LLC 2.1. PER 280-48(6)-12 - GASOLINE SERVICE STATION REQUIRES SPECIAL EXCEPTION BY BOARD OF APPEALS. P.O. BOX 547 m 2.2. PER 280-48(A).2(A) - RETAIL STORE > 1,200 SF CONSIDIERED 2nd PRINCIPAL USE. LAUREL, NY 11948 POINT 3. BULK REQUIREMENTS: CODE SECTION: PERMITTED: PROVIDED: 2. THIS PLAN REFERENCES: / aza• - A SURVEY PREPARED BY: ENGINEERING MIN. LOT SIZE: § 240-48-c-5 60,000 SF 63,308 SF (1.453 ACRES) NATHAN TAFT CORWIN III DATED: 8/9/23 MIN. FRONT YARD: § 280-50a 100' MAIN RD. (NYS 25) - FLOOR PLANS & ELEVATIONS PREPARED BY: 75.9' (BLDG.)** PY) THIS FIRM DATED: 5/23/24 (REV. 1) PROP. CONC. CURB 44.s' (CANOPY)** � (NYSDOT ITEM 1860 WALT WHITMAN ROAD OLD MAIN RD, 3. ANY BROKEN OR HAZARDOUS SIDEWALK, DRIVEWAY APRONS OR CURB ADJACENT TO THE SUBJECT SITE #609.0401) (TYP.) SUITE 600 66.2' (BLDG.)** SHALL BE REPLACED IN ACCORDANCE WITH CURRENT COUNTY/ TOWN STANDARDS. o �� �' MELVILLE,NY 11747 33.8' (CANOPY)** 4. CURB-CUTS AND/ OR ACCESS TO TOWN, COUNTY, STATE, ETC. HIGHWAYS SHALL BE CERTIFIED BY THE 'GJ MUNICIPALITY HAVING JURISDICTION. (516)777-4320 FAX: (516)777-4321 MAX. STRUCTURE FRONTAGE (LENGTH): § 280-50c 60' 58.3' (BLDG.) 5. DEBRIS SHALL NOT BE BURIED ON THE SUBJECT SITE. ALL UNSUITABLE MATERIAL AND DEBRIS SHALL BE SAT MEET EXIST. SIDEWALK/ GRADE/ 59.0' (CANOPY) DISPOSED OF IN ACCORDANCE WITH ALL LOCAL TOWN, COUNTY, STATE AND FEDERAL LAWS AND APPLICABLE Vs/ LL.: CURB/ ROADWAY FLUSH CODES. I / ALL PHASES OF ENGINEERING DESIGN MIN. STRUCTURE SETBACK FROM R.O.W. § 280-50c 75' .MAIN RD. (NYS 25) 6. THE OWNER/ CONTRACTOR SHALL BE FAMILIAR WITH AND RESPONSIBLE FOR ANY/ ALL CERTIFICATIONS, s - • ' 75.9' (BLDG.) INSPECTIONS, ETC. REQUIRED BY ALL GOVERNING JURISDICTIONAL AGENCIES DURING AND AFTER �'. N SURVEYING,CODE CONSULTING, 44.6' (CANOPY) EXIST. 'SPEED LIMIT IOIF ** CONSTRUCTION FOR SIGN-OFF AND CERTIFICATE OF OCCUPANCY ISSUANCE, INCLUDING BUT NOT LIMITED TO 40"SIGN TO REMAIN / °s. 0, COPAM REALTY COMPANY ZONING ANALYSIS &BID SPECIFICATION PROCUREMENT OF SERVICES, SCHEDULING OF FIELD OBSERVATIONS AND COORDINATION WITH " OLD MAIN RD. REPRESENTATIVES OF THE APPROPRIATE PARTIES. 66.2' (BLDG.)** 7. ENGINEER OF RECORD NOT RESPONSIBLE FOR PREPARATION, MONITORING OR REVIEW OF CONTRACTOR'S ° : �6'•S� ZONE: GENERAL BUSINESS (B) ** SITE SAFETY PLAN. CONTRACTOR ACKNOWLEDGES THAT COMPLETE RESPONSIBILITY FOR JOB SITE SAFETY �s USE: McDONALDS RESTAURANT www.HPEng.com 33.8' (CANOPY) f O LIES WITH HIMSELF AND THOSE PARTIES UNDER HIS DIRECTION. /�u A� MIN. LOT WIDTH: § 280-ATTACHMENT 4 150' 462.42' 8. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE EXACT LOCATION AND DEPTH OF ALL UNDERGROUND CHRIS M. TARTAGLIA MIN. LOT DEPTH: § 280-ATTACHMENT 4 150' 95.20' APPURTENANCES (WHETHER DEPICTED ON THESE PLANS OR NOT) PRIOR TO THE START OF WORK. THE / ` ��� CONTRACTOR MUST CONTACT THE "ONE CALL" SYSTEM TO ENSURE THAT ALL UTILITIES ARE PROPERLY AND / a F p MIN. SIDE YARD: § 280-ATTACHMENT 4 25' 25' (BLDG.) COMPLETELY MARKED OUT PRIOR TO PERFORMING ANY WORK. ANY DISCREPANCIES BETWEEN THE FIELD 9 LOCATIONS AND THE PLANS MUST BE VERIFIED BY THE CONTRACTOR. ANY DAMAGE OR STRUCTUREpF NEW 124.6' (CANOPY) DISTURBED DURING CONSTRUCTION MUST BE REPAIRED OR REPLACED AT THE CONTRACTOR'S EXPENSE. P MAR 9. CONTRACTOR TO COORDINATE W/ ENVIRONMENTAL CONSULTANT TO CONFIRM IF EXISTING MONITORING WELLS k MIN. REAR YARD: § 280-ATTACHMENT 4 35' N/A (CORNER LOT) DISTURBED/ REMOVED DURING CONSTRUCTION MUST BE REPLACED. / ) MIN. LANDSCAPE AREA PERCENTAGE: § 280-ATTACHMENT 4 35% 36,742 SF (58.0%) en. ` * Cr MAX. LOT COVERAGE: § 280-ATTACHMENT 4 30% 7,148 SF (11.3%) ` J MAX. BLDG. HT./ STORIES: § 280-ATTACHMENT 4 35'/2 STORIES 33'-6"/2 STORIES C� CORNER LOT SIGHT LINE DISTANCE: § 280-106(A) 30' SIDES COMPLIES / ;C � 078209 MIN. ACCESSORY STRUCTURE SETBACK § 280-15(B) 20' 25' (TRASH ENCLOSURE) PROP. CONC. CURB / ` / PROh� GINEER FOR SIDE AND/OR REAR YARD (NYSDOT ITEM / ` NEW YORK LICENSE No. 078209 (FOR LOT SIZE 60,000-79,999 SF): #609.0401) (TYP.) O MIN./ MAX. DRIVEWAY WIDTH: § 280-48(B)1 2(a) 12'/30' 30' (MAIN RD. NYS 25) °' s LAWRENCE D. 0 BRIEN 30' (OLD MAIN RD.) . . PROP. 9'X19' LANDBANKED �O� MIN. DRIVEWAY DIST. FROM ADJACENT F'L: § 280-48(8)12(a) 10' 172.0' °� y/ PARKING STALL FOR FUTURE USE EXIST �/ AS REQUIRED (TYP. OF 12) MIN. TANK DIST. FROM ADJACENT FL': § 280-48(B)1 2(e) 35' 105.5' O INLET TO "' ;, LINE OF EXIST REMAIN DENSE VEGETATION MIN. DISP. DIST. FROM R.O.W. IL': § 280-48(B)I 2(f) 15' 46.1' / o�t7 TO REMAIN MIN. TANK FROM R.O.W. FI'_ § 280-48(B)1 2(f) 15' 15' MIN. DIST. FROM CHURCH, § 280-48(B)l2(g) 300' 1.5 MILES (MATTITUCK-CUTCHOGUE �� ��� / / A� SCHOOL, ETC. JR./SR. HIGH SCHOOL) 11 PARKING & LOADING QQ�.� O / EXIST REMAIN UTILITY ITY POLE PROP, 1 •8•0 O ^�� LANDSCAPE AREA PROP. FENCE TO MIN. # OF STALLS-CONVENIENCE STORE § 280-78(a) 1/100 GFA (TYP.) / / MEET EXIST. PROFESSIONAL ENGINEER 2,800/100 = ® O 1 VEGETATION LINE NEW YORK LICENSE No. 082537 28 STALLS o � �� UNLESS APPROVED BY ALL AGENCIES HAVING MIN. # OF STALLS-OFFICE § 280-78(a) 1/100 GFA `mil J� G��O / PROP. 6 H JURISDICTION, THESE PLANS ARE NOT TO BE UTILIZED Q O 3'R PROP. 20'x41' SOLID PVC FOR CONSTRUCTION. OWNER CONTRACTOR ARE 22 STALLS = I(` 0�5 LOADING STALL / / 22 STALLS � GJ' FENCE ALONG R RESPONSIBLE FOR CONFIRMING ALL REQUIRED AGENCY `, APPROVALS HAVE BEEN SECURED PRIOR TO MIN. # OF STALLS-GAS STATION § 280-78(a) 1/EMPLOYEE G COMMENCEMENT OF WORK, WHETHER DESCRIBED ON 3 STALLS o �� �y POGO THESE PLANS OR OTHERWISE. cd F �� �� PROP. STOP SIGN O REVISIONS 53 STALLS 12 LANDBA36 STALLSNKEDLSTALLS" ��PFF� \ 6 tiJ .' /'/4 FACING SOUTH "�' / rLro 5 REV NO. DATE REVISION MIN. STALL SIZE: § 280-78(c): 9'xl9, 9'x19' �� �y,` O� 12 �� 1 5111126 REV TANKS MIN. LOADING STALLS: § 280-79(A)3: 4,906 SF < 5,000 SF N/A PROP. SAWCUT & ASPHALT FF �'• ! d p. PROP. LOADING RAMPS Off, �.d LEGEND PAVEMENT REPLACEMENT �F emu" �� \� PROP. 1O'x2O'x6'H (ALL ITEMS EXISTING TO REMAIN UNLESS NOTED OTHERWISE) MIN. OF STREET TREES: § 280-93: 1 40' LOT FRONTAGE: 14 STREET TREES** (NYSDOT ITEM # / '', O MASONRY TRASH 1,077.93' / 40' = 27 TREES #203.50140363) ' ENCLOSURE ON PROP. CONC. CURB RAMP G r'�y,, CONC. MAT PROPERTY LINE FRONT LANDSCAPED AREA: § 280-93(B): 25' ALONG FRONT LOT LINE MAIN RD. (NYS (NYSDOT TYPE 1 ��p '9' co a 1 OVERHEAD 25.0' CONFIGURATION W/ f+ cJ HATCHED AREA CO LINE OLD MAIN RD. OPTION C: CURB RETURN 10.0'** & OPTION 2 DETECTABLE / P ° 9� BUILDING ING ENVELOPE C° UTILITY POLE WARNING PLACEMENT) a < GUY WIRE FRONT LANDSCAPED AREA: § 280-93(B): LANDSCAPE AREA OF 5' WIDE NONE PROVIDED** o (TYP. OF 4) 9 9' �0p` 25' ® INLET ABUTTING THE FRONT OF THE BUILDING (TRASH ** y50 ,'f ` �3` �yP a ENCLOSURE) SIGN LANDSCAPED PARKING AREA: § 280-95(A): 10 SF INTERIOR LANDSCAPE NONE PROVIDED y�P ,D. �p O� . AREA / PARKING SPACE yp 4L\�1� 3'R `` PROP. "STOP" SIGN �'° �' ' �O �� in 10 SF x 53 SPACES = O / J I CONCRETE CURB 530 SF o Q�OQQO I' eo FACING SOUTH PROP. 2 STORY "\ PROPOSED CONCRETE CURB PROP. CONC. O8 s CONVENIENCE STORE r i * INDICATES EXISTING CONDITION TO REMAIN EXIST. ID SIGN TO BE / CURB (TYP.) PROPOSED FLUSH CONCRETE CURB PROP. TRASH (4,906 SF GFA.) u`i' N 0 F ** INDICATES VARIANCE REQUIRED FOR PROPOSED CONDITION REMOVED RECEPTACLE O9 6'� / / 33'R (TYP. OF 2) y°'�,� STANLEY J. FLISS JR. PROPOSED AREA LIGHT W/ SHIELD EXIST. PROPANE J ROP. CANOP� N & JANICE M. FLISS STORAGE CAGE TO OVER CONC. 1 ° 100' FRONT YARD SETB ZONE: GENERAL BUSINESS (B) G PROPOSED WALL MOUNTED AREA LIGHT BE REMOVED 3'R uo, F ELNG MAT USE: RESIDENCE -1st FLOOR 2,800 SF '+ C PROPOSED CONCRETE PAVEMENT THE EDUCATION LAW OF THE STATE OF NEW YORK PROHIBITS ANY / ��y st• 10'R J / '�� 1 CONVENIENCE STORE/ PERSON ALTERING ANY ON THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATIONS, UNLESS IT IS UNDER THE J (y RETAIL AREA: 1,231 SF PROP. SINGLE ` PROPOSED GRASS AREA IN R.O.W. DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. WHERE SUCH FIXTURE AREA OP. BRIICK -2nd FLOOR 2,106 SF 25' ALTERATIONS ARE MADE, THE PROFESSIONAL ENGINEER MUST SIGN ENCASED CANOPY OFFICE AREA: 1,868 SF AND SEAL, DATE AND DESCRIBE THE FULL EXTENT OF THE '' , +� LIGHT W/ O STAIRWELL AREA: 238 SF (BLDG.) ALTERATION ON THE DRAWING AND/OR IN THE SPECIFICATIONS. COLUMN (T'YP. OF 6) PROPOSED ASPHALT PAVEMENT IN ���' ( SHIELD (TYP.) ® (NO BASEMENT) NYSDOT R.O.W. (NYS EDUCATION LAW SECTION 7209-2) �S. +R EXIST. MANHOLE COVER �® `G\OQ p' PROPOSED ASPHALT PAVEMENT IN PROP. 5' WIDE �I �� TO BE REMOVED L / / / I TOWN R.O.W. CONC. SIDEWALK (NYSDOT ITEM Q4` a �'� ��'� ss, ` e• #608.01000010) O - - - - - - - - - 1 PROPOSED PARKING STALL COUNT (TYP.) ": \�� PROP. FLAG POLE p� �1 sue, PROP. PROP. FENCE TO PROPOSED SOLID PVC FENCE U-BOLLARDMEET EXIST. � aMCDD (TYP.) VEGETATION LINE ROPOSED SIGN PROPOSED PIPE BOLLARD JUN 1 7 2026 J \ `O ® `L� C1 PROP. 8'x19' ADA PROP. BICYCLE PARKING SIGN - ® PROPOSED INLET PARKING & LOADING w. MOUNTED TO POST (MUTCD D4 3) N ® PROPOSED SOLID COVER SOUTHOLD TOWN �0� �� / STALLS PLANNING BOARD EXIST. ^ PROPOSED FLAG POLE GUARDRAIL TO , , RACK ONVCON C PAD v " ` BE REMOVED PROP. 3 x5 CONC. " q I Q o y LIMIT OF VEGETATION PROP. CONC. CURB OO �60 I d\ ISLAND W/ (1) MPD W (TYP. OF 2) Z (NYSDOT ITEM I I ^ o o PROPOSED BIKE RACK #609.0401) (TYP.) A' I I (TYP. OF 4 ' PROPOSED U-BOLLARD ���� / e . 20,00 ON DOUBLE v �' EXIST. (1) STORY 1t PROP GALL E Q PROPOSED AIR STATION �� BUILDING TO n 9 WALL FIBERGLASS N o SITE ADDRESS. PROP. GRASS AREA (NYSDOT �� REMOVED UNDERGROUND STORAGE TANKS � PROPOSED VACUUM STATION ITEM #610.16010020) (TURF ° / °\ 1,600 sF PROP. VACUUM Q oo ( ) STATIONS ON ^ PROPOSED CONVENIENCE STORE ESTABLISHMENT) (TYP.) P i I I I CONC. PEDESTALS Do L" O PROPANE-CYLINDER A b WITH FILLING STATION EXC/ ® ° • EXIST. DISP. ON I �' �\ 51R PIPE BOLLARDS ANGE E W/ N • CONC. ISLAND TO \ I LIGHT TO E \ 0 ♦ O _ 7400 MAIN ROAD BE REMOVED s LINE OF EXIST. Medical GtoU (TYP. OF 5) \ I I REMOVED PROP. "STOP" SIGN z Q _ DENSE VEGETATION 17 MATTTUCK, FACING NORTH �, TO REMAIN - _ TOWN OF SOUTHOLD PROP. CONC. CURB RAMP (NYSDOT TYPE 1 CONFIGURATION �� �, / / \ __-_ --- �_ �, ^'� �' i 5 T �.y.y. SUFFOLK COUNTY, NY 11952 $7`.•�2.'.1` S �" 8 W`A07w'.`'`' .`PROP• AIR 4 - W OPTION A: FLARED CURB & e ✓ - / I�3 7: wily, J O S`. `.VACUUM OPTION 1 DETECTABLE WARNING R P OP. LANDSCAPE i 10`-STAY NS ON DISTRICT: 1 s / 000 BLOCK: 07 PLACEMENT T I tr I rr s D I� 8 AREA `-`-a •'•`-`�`�'- 3 a1 e C (TYP.) PROP. 0 y / . '.`C S. .EXIST.-� -CONC. PEDESTALS(' el hi 1tV Uc S 010 0 09 1 >1 1 k (NYSDOT ITEM 608. 50 0 SECTION: 12 2 LOTS: 1 & 3.� 2 # / / • i .;��j .;0.'.`.`•'. OVERHEAD WIRE` CURB CUT �`` ' .�� E EXI . O' TO BE REMOVED` ` ` 1 R ' 1 R. M ET ST GRADE/ - _ _ ROADWAY FLUSH e�1c; V ri , SCALE. 1"_20' HPE# EMPO 1-01 PROP. GRASS AREA ---=--=-=�== / '�`- _ � .�i 2 � L7•'.`.`.`.`.".'.`.`.`.`�'.`.'.'.'.'.`.`.`.`.`.'.'.`.`.`.`.`.`. .�.�/�/ PROP. GRASS PROP. SAWCUT & ASPHALT Elrrler'sCusCarn Amish Furniture IN R.O.W. (TYP.) - - -- +-,.�L• �� / A I L �' DATE.• 4 9 26 DWG #' EMP021-01-CC.1 � -�!;• - ,�,,,� AREA N R.O.W. PAVEMENT REPLACEMENT PER TOWN / � PROP. CONC. CURB PER TOWN OF TYP. OF SOUTHOLD REQUIREMENTS TYP. a .. (TYP.) (TYP.) DRAWN BY. LID CHECKED BY. CT SOUTHOLD REQUIREMENTS Exrsr. SW. Exisr. unurY rrrLE• POLE TO REMAIN ° FREESTANDIING ,� "�� !T v�irlcl! �rr� a ro° 0 REMAIN'lGN .9yv�� * ALTERNATE o i". iuntry Time.Cycle EXIST. MONITORING WELL TO BE REMOVED _ rn SITE CONCEPT PLAN / LL-•-LL, - � y� E GENERAL . . . .. . . . . . NOTE (TYP SE TRAFFIC FLOW # ) ROAD r µ 9 ALTERNATE CONCEPT _.,..:�- ""`��� > /- EXIST. TANK VENT PROP. CONC. CURB PER TOWN OLD MAIN k C RISERS TO BE REMOVED OF SOUTHOLD REQUIREMENTS GRAPHIC SCALE PLAN C FOR REVIEW EXIST. AREA LIGHIT TO 20 0 10 20 (TOWN JURISDICTION) BE REMOVED EXIST, DOUBLE WALL PURPOSES ONLY, NOT µ""'• - 12'R FIBERGLASS UNDERGROUND TRAFFIC FLOW EXIST. FLAG POLE TO FOR CONSTRUCTION. Laurel Links SHEET N0: Country Ghats BE REMOVED STORAGE TANKS TO BE EXIST. PAVEMENT EXIST. MASONRY REMOVED 18F STRIPING TO BE PLANTER TO BE ( IN FEET ) El RE-STRIPED REMOVED 1 inch = 20 ft. KEY MAP- IN-KIND (NYSDOT N.T.S ITEM #619.002) REV. 1 OF 1 I HIGH Q 16'-0 " POINT ENGINEERING N .d 1860 WALT WHITMAN ROAD SUITE 600 o MELVILLE,NY 11747 (516)777-4320 FAX: (516)777-4321 1 E ALL PHASES OF ENGINEERING DESIGN, N/0/F SURVEYING,CODE CONSULTING, J' COPAM REALTY COMPANY ZONING ANALYSIS &BID SPECIFICATION ZONE: GENERAL BUSINESS (B) o., 3'—O)" 1O'—O" USE: McDONALDS RESTAURANT www.HPEng.com fig. '� / 70,<o FF�a CHRIS M. TARTAGLIA of �E�� PASSENGER VEHICLE 5/ ��,� , RKro� NTS / Q`A r � y / �sF 078209 / FESSIO�P�, / NAL ENGINEER ` NEW YORK LICENSE No. 078209 / / IQ,, LAWRENCE D. O 'BRIEN moo° PGA•/ �O oe � _, ,� :� / / PROFESSIONAL ENGINEER O NEW YORK LICENSE No. 082537 UNLESS BY ALL � ; p�q,`��°,�q�rFoo�����' �O ° JURISDICTION,OHESE PLANSA ARE CNOT TOING BE UTILIZED G \ '� =- •.� �'�y���y�Cl � G' 1\3 �,�. . / FOR CONSTRUCTION. OWNER/ CONTRACTOR ARE cp A gyp ! RESPONSIBLE FOR CONFIRMING ALL REQUIRED AGENCY �`` ��O� , � �, „�`=_ 9 �• �� O 9 'rA ", � APPROVALS HAVE BEEN SECURED PRIOR TO ��O C � J' �q �'✓ 'r �A S,t �'`F' G� COMMENCEMENT OF WORK, WHETHER DESCRIBED ON THESE PLANS OR OTHERWISE. REVISIONS o REV NO. DATE REVISION 1 10111125 MISC. REVS o FF�G PROP. 3'x5' P / CONC. ISLAND / W/ i(1) MPD / (TYP,. OF 6) / s ° v CD / I (0 o / Sys o 0 STANLEY JO FLISS JR. � ® PROP. 50'x74'CANOPY ABOVE & JANICE M. FLISS ZONE: GENERAL BUSINESS (B) �0 CONC. FUELING USE; RESIDENCE MAT. I THE EDUCATION LAW OF THE STATE OF NEW YORK PROHIBITS ANY / Q PERSON ALTERING ANYTHING ON THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATIONS, UNLESS IT IS UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. WHERE SUCH ALTERATIONS ARE MADE, THE PROFESSIONAL ENGINEER MUST SIGN AND SEAL, E D DESCRIBE L EXTENT OF THE ALTERATION ONTHEDRAW DRAWING AND/OR IN THE SPECIFICATIONS. (NYS EDUCATION LAW SECTION 7209-2)� PROP. (3) VEHICLE I / QUEUING AT EACH / DISPENSER (TYP.) / / ® O MCCK OML=D / l I DEC 2 3 2025 'O< O�„ O °�«/.° U SOUTHOLD I PLANNING BOARD i < o S17E ADDRESS.- NPROPOSE N WITH FILLING STATION CONVENIENCE STORE / LL==I== -l-==t==== -L —I— L= L_ =I-==�=_ — 7400 MAIN ROAD Medical Group r,- MATTITUCK, r � �. �_ _ _ �_ � ._ _�_ _ � _� � _ _ _ _� � � �,��- �,✓'`'' � TOWN OF SOUTHOLD �° . SUFFOLK COUNTY, NY 11952 / S 87°14'5—W 87.22' S 89°48'00" W ACT. 197.14' t# 7�!!I!F an / T Total Dental Care DISTRICT: 1000 BLOCK: 07 , ' �, ® O of f,ovi.tuck ': SECTION: 122 LOTS: 1 & 3.2 / ♦ 11$ Ste' HPE McD�na1 's 1"=20' #' EMP02701 Amish Furniture' ,r`, 411 DATE.• 10/9/23 DWG /-'EMP021-01—CP.B.1 PROP. 30' CURB CUT �,,�'"{� `�`?c D�' LD/ GG CHECKED BY.• CT Gulf TITLE.- / S g H 'mind Farm' auntry Time Cycle 40 VEHICLE 000 .00 TRAFFIC FLOW f V E ��� � .�`"�,,- . ��_� ......_._ .._....f•torl0r)OrEek.. PLAN sop OLD MAIN ROAD . (TOWN JURISDICTION) GRAPHIC SCALE TRAFFIC FLOW 20 o to 20 Laurel Links " SHEET NO. Country Club 91 ( IN FEET ) KEY MAP WPI::] 1 inch = 20 ft. N.T.S REV. 1 OF 1 I BULK REQUIREMENTS GENERAL NOTES 1. ZONE: GENERAL BUSINESS (B) DISTRICT 1. PROPERTY OWNER/ APPLICANT: HIGH nr 2. USE: AMAC INC. & 535 OLD MAIN REALTY LLC Q 2.1. PER 280-48(B)-12 - GASOLINE SERVICE STATION REQUIRES SPECIAL EXCEPTION BY BOARD OF APPEALS. P.O. BOX 547 m 2.2. PER 280-48(A).2(A) - RETAIL STORE > 1,200 SF CONSIDERED 2nd PRINCIPAL USE. LAUREL, NY 11948 POINT 3. BULK REQUIREMENTS: CODE SECTION: PERMITTED: PROVIDED: 2. THIS PLAN REFERENCES: - A SURVEY PREPARED BY: ENGINEERING MIN. LOT SIZE: § 240-48-c-5 60,000 SF 63,308 SF (1.453 ACRES) NATHAN TAFT CORWIN III DATED: 8/9/23 MIN. FRONT YARD: § 280-50a 100' MAIN RD. (NYS 25) - FLOOR PLANS & ELEVATIONS PREPARED BY: 25.0' (BLDG.)** THIS FIRM 38.6' (CANOPY)** DATED: 5/23/24 (REV. 1) PROP. CONIC. CURB 1860 WALT WHITMAN ROAD (NYSDOT ITEM OLD MAIN RD. 3. ANY BROKEN OR HAZARDOUS SIDEWALK, DRIVEWAY APRONS OR CURB ADJACENT TO THE SUBJECT SITE #609.0401) (TYP.) SUITE 600 153.7' (BLDG.)** SHALL BE REPLACED IN ACCORDANCE WITH CURRENT COUNTY/ TOWN STANDARDS. a. 66.5' (CANOPY)** 4. CURB-CUTS AND/ OR ACCESS TO TOWN, COUNTY, STATE, ETC. HIGHWAYS SHALL BE CERTIFIED BY THE o �yJ MELVILLE,NY 11747 MUNICIPALITY HAVING JURISDICTION. 516 777-4320 FAX: 51 MAX. STRUCTURE FRONTAGE (LENGTH): § 280-50c 60' 48.0' (BLDG.) 5. DEBRIS SHALL NOT BE BURIED ON THE SUBJECT SITE. ALL UNSUITABLE MATERIAL AND DEBRIS SHALL BE / ( ) ( 6)777-4321 50.0' (CANOPY) DISPOSED OF IN ACCORDANCE WITH ALL LOCAL TOWN, COUNTY, STATE AND FEDERAL LAWS AND APPLICABLE / MEET EXIST. SIDEWALK/ GRADE/ CODES. �?pp" CURB/ ROADWAY FLUSH MIN. STRUCTURE SETBACK FROM R.O.W. § 280-50c 75' MAIN RD. (NYS 25) 6. THE OWNER/ CONTRACTOR SHALL BE FAMILIAR WITH AND RESPONSIBLE FOR ANY/ ALL CERTIFICATIONS, C �j / s : : ' ALL PHASES OF ENGINEERING DESIGN, 25.0' (BLDG.)** INSPECTIONS, ETC. REQUIRED BY ALL GOVERNING JURISDICTIONAL AGENCIES DURING AND AFTER LJ EXIST SPEED LIMIT / ° D N 0 F SURVEYING,CODE CONSULTING, 38.6' (CANOPY)** CONSTRUCTION FOR SIGN-OFF AND CERTIFICATE OF OCCUPANCY ISSUANCE, INCLUDING BUT NOT LIMITED TO o 40"SIGN TO REMAIN / / P e J' COPAM REALTY COMPANY ZONING ANALYSIS &BID SPECIFICATION PROCUREMENT OF SERVICES, SCHEDULING OF FIELD OBSERVATIONS AND COORDINATION WITH OLD MAIN RD, REPRESENTATIVES OF THE APPROPRIATE PARTIES. 153.7' (BLDG.)** 7. ENGINEER OF RECORD NOT RESPONSIBLE FOR PREPARATION, MONITORING OR REVIEW OF CONTRACTOR'S '�' �6+,s� ZONE: GENERAL BUSINESS (B) 66.5' (CANOPY)** SITE SAFETY PLAN. CONTRACTOR ACKNOWLEDGES THAT COMPLETE RESPONSIBILITY FOR JOB SITE SAFETY / J►. �`r0 USE: McDONALDS RESTAURANT www.HPEng.com LIES WITH HIMSELF AND THOSE PARTIES UNDER HIS DIRECTION. S ��'/ MIN. LOT WIDTH: § 280-ATTACHMENIT 4 150' 615.51' 8. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE EXACT LOCATION AND DEPTH OF ALL UNDERGROUND °.' O�<, MIN. LOT DEPTH: § 280-ATTACHMENT 4 150' 55.7'* APPURTENANCES (WHETHER DEPICTED ON THESE PLANS OR NOT) PRIOR TO THE START OF WORK. THE CHRIS M. TAR TA GLIA CONTRACTOR MUST CONTACT THE 'ONE CALL" SYSTEM TO ENSURE THAT ALL UTILITIES ARE PROPERLY AND / °� a FO COMPLETELY MARKED OUT PRIOR TO PERFORMING ANY WORK. ANY DISCREPANCIES BETWEEN THE FIELD MIN. SIDE YARD: § 280-ATTACHMENJT 4 25' 11.7' (BLDG.) LOCATIONS AND THE PLANS MUST BE VERIFIED BY THE CONTRACTOR. ANY DAMAGE OR STRUCTURE F NEW Yp 57.5' (CANOPY) DISTURBED DURING CONSTRUCTION MUST BE REPAIRED OR REPLACED AT THE CONTRACTOR'S EXPENSE. � � .`P MARK T 9. CONTRACTOR TO COORDINATE W/ ENVIRONMENTAL CONSULTANT TO CONFIRM IF EXISTING MONITORING WELLS N / $ C'7 4 MIN. REAR YARD: § 280-ATTACHMEMIT 4 35' N/A (CORNER LOT) DISTURBED/ REMOVED DURING CONSTRUCTION MUST BE REPLACED. Q �� MIN. LANDSCAPE AREA PERCENTAGE: § 280-ATTACHMEMT 4 35% 31,144 SF (49.1%) MAX. LOT COVERAGE: § 280-ATTACHMEMT 4 30% 6,498.4 SF (10.3%) - MAX. BLDG. HT./ STORIES: § 280-ATTACHMEMT 4 35'/2 STORIES 33'-6"/2 STORIES i1;F;.�9 CORNER LOT SIGHT LINE DISTANCE: § 280-106 A 30' SIDES COMPLIES MIN. ACCESSORY STRUCTURE SETBACK § 280-15(B) 20' 296.9' (TRASH ENCLOSURE) PROP. CONIC. CURB / PRO L ENGINEER FOR SIDE AND/OR REAR YARD (NYSDOT ITEM / ` NEW YORK LICENSE No. 078209 (FOR LOT SIZE 60,000-79,999 SF): #609.0401) (TYP.) � •' MIN./ MAX. DRIVEWAY WIDTH: § 280-48(B)12(a)) 12'/30' 30' (MAIN RD. NYS 25) o lo�'-J °'6�Gl LAWRENCE D. O'BRIEN 30' OLD MAIN RD. 0 O. MIN. DRIVEWAY DIST. FROM ADJACENT F1': § 280-48(B)12(a,) 10' 172.0' MIN. TANK DIST. FROM ADJACENT R: § 280-48(B)12(e)) 35' 289.3' o INLET O / p '�° E A r LINE OF EXIST. PROP. 1 DENSE VEGETATION MIN. DISP. DIST. FROM R.O.W. 1L': § 280-48(B)12(f) 15' 49.5' / �� '. ;,� i4 % �� A NDSCAPE TO REMAIN MIN. TANK FROM R.O.W. R § 280-48(B)12(f)► 15' 31.0' SOON y / ��/ TOIREMA-NITY POLE / ® `•;� e� %AREA (TYP.) MIN. DIST. FROM CHURCH, § 280-48(B)12(g,) 300' 1.5 MILES (MATTITUCK-CUTCHOGUE �y yF�P �� �N� SCHOOL, ETC. JR./SR. HIGH SCHOOL) pR PARKING & LOADING O Q��Q� � 11•' Q ,, l!����� O � s MIN. # OF STALLS-CONVENIENCE STORE § 280-78(a) 1/100 GFA / PROP. FENCE TO '� �' ` ' / MEET EXIST, PROFESSIONAL ENGINEER 2,800/100 = ® O '�� ;: '' < 00 �s� e90 �r < . VEGETATION LINE NEW YORK LICENSE No. 082537 28 STALLS o rLGJ1 ® s r ��4'���p 6' �� \ PROP. 6 H o y c� 1 SOLID PVC � UNLESS APPROVED BY ALL AGENCIES HAVING MIN. # OF STALLS-OFFICE § 280-78(a) 1/100 GFA J� O�� �` 9ffo ,� yr� Off, O FENCE ALONG �' JURISDICTION, THESE PLANS ARE NOT TO BE UTILIZED 2,106/100 / 3 R< �oylo��o� / y O y r� / FOR CONSTRUCTION. OWNER CONTRACTOR ARE 22 STALLS P C,%- �� �l cyy'A r ���0 O RESPONSIBLE FOR CONFIRMING ALL REQUIRED AGENCY \� ��� =._�9 9d i' 'r�°,�O O� ��,, �• APPROVALS HAVE BEEN SECURED PRIOR TO MIN. # OF STALLS-GAS STATION § 280-78(a) 1/EMPLOYEE _ ,�`' COMMENCEMENT OF WORK, WHETHER DESCRIBED ON 3 STALLS �O� �� � •o "STOP" A - - d � �"`� �' � � P ' �_ ' ��� 0`rr,- •>, � 000 THESE PLANS OR OTHERWISE. cp' F r� PROP. STOP SIGN 0 53 STALLS �G ti Jr. ° �� \\_ - J',1N.r `� I cJ hp 34 STALLS (INCL. 2 ADA + FF J / FACING SOUTH __-' REVISIONS 12 LANDBANKED STALLS** ARP 1�' !� / =' r' ° / °rL S REV NO. DATE REVISION MIN. STALL SIZE: § 280-78(c)• 9'x19' 9'x19' �O� / �,' ° T o \G F d' \ ° .. ;'y;_ / S S 1 10111125 MISC. REVS MIN. LOADING STALLS: § 280-79(A)3: 4,906 SF < 5,000 SF N/A PROP. SAWCUT & ASPHALT LEGEND PAVEMENT REPLACEMENT ��P PROP. BICYCLE PARKING SIGN MIN. # OF STREET TREES: § 280-93: 1 / 40' LOT FRONTAGE: 13 STREET TREES** (NYSDOT ITEM / �� �� `9' ' ALL ITEMS EXISTING TO REMAIN UNLESS NOTED OTHERWISE so G / MOUNTED TO POST (MUTCD D4-3) ( ) 1,077.93' / 40' = 27 TREES #203.50140363) mod' PROPERTY LINE PROP. CONIC. CURB RAMP % p ems, 9 �. 6 PROP. INVERTED U FRONT LANDSCAPED AREA: § 280-93(8): 25' ALONG FRONT LOT LINE MAIN RD. (NYS 25) o� (NYSDOT TYPE 1 y�A� PROP. 8'x19' ADA BICYCLE RACK ON orl 25.0' CONFIGURATION W/ / J: -� PARKING & LOADING �°� 1 co CONC. PAD OVERHEAD LINE OLD MAIN RD, OPTION C: CURB RETURN / .'-`-` / STALLS `yQ' a ( � (TYP. OF 2) � UTILITY POLE 16.6'** & OPTION 2 DETECTABLE �L WARNING PLACEMENT) : -G GUY WIRE FRONT LANDSCAPED AREA: § 280-93(B): LANDSCAPE AREA OF 5' WIDE NONE PROVIDED** OF 4) .° �"' ABUTTING THE FRONT OF THE p ''' PROP. BUILDING PROPANE-CYLINDER ® INLET 1y J��P 3 R / �p�1 EXCHANGE CAGE W/ SIGN LANDSCAPED PARKING AREA: § 280-95(A): 10 SF INTERIOR LANDSCAPE NONE PROVIDED** 5� R� G�' PIPE BOLLARDS AREA / PARKING SPACE �OQ 'j O / I ` PROP. "STOP" SIGN ` PROP. 50'x74' CONCRETE CURB 10 SF x 53 SPACES = Q �yQ�'' / I FACING SOUTH CANOPY OVER 530 SF o PROP. TRASH �PROP. � CONIC. FUELING PROPOSED CONCRETE CURB * INDICATES EXISTING CONDITION TO REMAIN EXIST. ID SIGN TO BE / RECEPTACLE U-BOLLARD O® MAT (3,700 SF) 5'R ** INDICATES VARIANCE REQUIRED FOR PROPOSED CONDITION REMOVED TYP. �e �T' N101F - - PROPOSED FLUSH CONCRETE CURB 33 R (TYP. OF 2) ( ) Fy STANLEY J. FLISS JR. EXIST. PROPANE ® 3'R PROPOSED CURB RADII STORAGE CAGE TO �3'R 57.5 & JANICE M. FLISS PROP. CONIC. Q� (CANOPY) ZONUSE: RESIDENCE: GENERAL BUSINESS (B) PROPOSED AREA LIGHT W/ SHIELD BE REMOVED t. , 10 R CURB (TYP.) PROP. BRICK THE EDUCATION LAW OF THE STATE OF NEW YORK PROHIBITS ANY ENCASED CANOPY COLUMN (TYP. OF 6)Q PROPOSED WALL MOUNTED AREA LIGHT PERSON ALTERING ANYTHING ON THESE DRAWINGS AND/OR THE J o PROP. SINGLE ACCOMPANYING SPECIFICATIONS, UNLESS IT IS UNDER THE �, ° • FIXTURE AREA 12.8' PROPOSED CONCRETE PAVEMENT DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. WHERE SUCH / • \ ALTERATIONS ARE MADE, THE PROFESSIONAL ENGINEER MUST SIGN D LIGHT W/ ® (PARKING) AND SEAL, DATE AND DESCRIBE THE FULL EXTENT OF THE 10 R SHIELD (TYP.) �� PROPOSED GRASS AREA IN R.O.W. ALTERATION ON THE DRAWING AND/OR IN THE SPECIFICATIONS. (1 V • �- , 4, PROP. ,3'x5' CONIC. ON EDUCATION LAW SECTION 7209-2) ` EXIST. MANHOLE COVER M PRO P PROP. 5' WIDE / A ' °�i ISLAND YP.1 OF 6) NYSDOT ER ASPHALT PAVEMENT IN TO BE REMOVED fl� CONC. SIDEWALK , �j��,fl• (NYSDOT ITEM PROP. SINGLE FIXTURE AREA A � 3 / /� PROPOSED ASPHALT PAVEMENT IN #608.01000010) $ LIGHT W/ SHIELD (TYP.) PROP. ASPHALT J �� TOWN R.O.W. (TYP.) / . .` `.`+ P �, PAVEMENT TYP. PROP. AIR/ VACUUM PROP. FENCE TO STATIONS ON CONC. PROPOSED PARKING STALL COUNT Exlsr. ( ) 0 PEDESTALS MEET EXIST. \ VEGETATION LINE PROPOSED SOLID PVC FENCE o �� V�V GUARDRAIL TO \J DD / PROP. AIR \ BE REMOVED , , l S PROPOSED SIGN - •`)`° ° - .�;�-' / \ PROP. 9 x19 \�� �\tJ I:TI .� I VACUUM �- PARKING STALL PROPOSED PIPE BOLLARD ��p� / STATIONS ON 41�7 DEC Z 3 2025 IE / II CONC. PEDESTALS \ RELOCATED `O O O °°) (TYP.) ® PROPOSED INLET � a�. �' SOUTHOLD TOWN PROP. CONIC. CURB 0 6�h / • / UNDERGROUND T -'- ® Q o ® PROPOSED SOLID COVER PLANNING BOARD D (NYSDOT ITEM O / I \ °\ STORAGE TANKS . . �, O """� o PROPOSED FLAG POLE #609.0401) (TYP.) I I <O° . ° b a e ma l 3'R 00 0 \ Y_. J 3 LIMIT OF VEGETATION \ EXIST. (1) STORY \ 10 R O PROPOSED BIKE RACK \( BUILDING TO BE �T- 25'R ( (V o PROP. GRASS AREA. (NYSDOT �\� I REMOVED II I I I I I I I I I �9 o PROPOSED U-BOLLARD SITE ADDRESS: ITEM #610.16010020) (TURF % 4 •"\ (1,600 sF) �I \ ° PROP. TANK n �,, II PROP. FLAG POLE � PROPOSED AIR STATION / I PROP. 10'X20'X6'H II I VENT RISERS I - ) I I I ° PROPOSED CONVENIENCE STORE ESTABLISHMENT) (TYP.) � I z� ,., r \ MASONRY TRASH II \ \ I I I I I I I I I �I 2� .n o �- PROP p o PROPOSED VACUUM STATION ENCLOSURE ON D I Z LANDSCAPE N WITH FILLING STATION / ° J • D• . \ ° I04 I�� i�� _ Igo i�� I�� I�� ��c� I�� I2a �210 I U �. DIP. ON CONC. MAT I \ o o AREA O > CONC. ISLAND TO a PROP. PAVEMENT Lt ==1-_- _l _ - I- - _ _I-_ L J=- I_ __ -__I__=� .... 7400 MAIN ROAD / (T REMOVED PROP. CGRASS n rn LINE OF EXIST Medlcil Grouti MATTITUCK, / (TYP. of s) , I ARROW STRIPING Q AREA IN R.O.W. o Z \ DENSE VEMAIN ON PROP. CONIC. CURB RAMP (TY (TYPP,)_ v TO REMAIN _ _ TOWN OF SOUTHOLD r / _ _ 12'R .,� ............ ;,- _ _ _ _. ..�_. .®.._ ; . SUFFOLK CO (NYSDOT TYPE 1 CONFIGURATION �,, / L _ ; / ° €37'.-22• : 4$ E1Q' SA! ACC ` LINTY, NY 11952 1��:a`4 FLARED CURB & 0' Will F on V<t W OPTION A: LA J $ / • " " TABLE WARNING JJ OPTION 1 DETECTABLE / PROP. LANDSCAPE • OP. STOP SIGN �, - I +o- DISTRICT: 0 1 00 BLOCK:�� K• 07 I P T n LAC M NT a D ttr a P E E at e I ACI G NORTH . . . ./ F RH . . . . . . . . . AREA TYP. i `EXIST. A - .' n'f•' XIS . REA+ �'" / .E T � , � e .s. k ram, +LIG 0 .010500009 HT r N SD T ITEM 608 0 Y 0 / � BE ` .�.,.1 SECTION ( # ) / , / / / • :a6 / /. OVERHEAD WIRE` � f -` L �� .G1 L. f' LOTS: 1 & 3.2 > 22 R/ / TO BE REMOVED`-`•`•`•`•`•` %%' ` REMOVED °L -1 MEET EXIST. GRADE/ f r °� / / /� ;� s. r tit. / / \` /' _,,._ `,v /� PROP. GRASS AREA / -L ROADWAY FLUSH / / PROP. 30' -- --. ./ �..�./-�- -L '�" PAcC ari�ld's SALE' 1 = 20' HPE# EMP021-01 p-`*.,.%•'•'-'% :�.- PROP. SAWCUT & ASPHALT Elmer'sCustom f „ Amish Furniture e 6 25 24 DWG //' EMP021-01-CP.B.1 � / �-� IN R.O.W. (TYP.) /' �,-��`.•-� ./--L L' PAVEMENT REPLACEMENT PER TOWN r / / Y � CURB CUT �� PROP. 9 X19 LANDBANKED s DATE.• �•`• PROP. CONC. CURB PER TOWN OF PARKING STALL FOR FUTURE USE } / 0 8 OF SOUTHOLD REQUIREMENTS (TYP.) ff ,c� DRAWN BY. CHECKED BY. . ®. . . . . / ��i� SOUTHOLD REQUIREMENTS AS REQUIRED (TYP. OF 12) 263.59' o LD LC `� s�1' ` /}'GJD -b`+ �' Gulf 60 / 5::"I:�g .� EXIST UTILITY TITLE. f H wind farm s EXIST ° o /I �► o POLE TO REMAINr FREESTANDING �� T T �� ' ° ID/PRICE SIGN s 7untry Tune Cycle r4L' 1\!fI ,, • ° TO REMAIN `� /�•`'•'-,• • •+``•,•,••••••••-`• ` L EXIST. MONITORING �,` ; y,'. .tr! VEX ®N�E�T ��AN WELL TO BE REMOVED / ° �� / (TYP. - SEE GENERAL TRAFFIC FLOW '' !� NOTE #9) ALTERNATE CONCEPT ,..r . --m Ilorlor, t"k �' /� PROP, CONC. CURB PER TOWN EXIST. TANK VENT 6 5' OF SOUTHOLD REQUIREMENTS OLD MAIN ROADPLAN B FOR REVIEW RISERS TO BE REMOVED 1 �° Z0GRAPHIC SCALE 0 10 20 (TOWN JURISDICTION) PURPOSES ONLY NOT EXIST. AREA LIIGHT TO q r BE REMOVED EXIST. DOUBLE WALL tr 12 R - ` FIBERGLASS UNDERGROUND TRAFFIC FLOW ' -EXIST. FLAG POLE TO FOR CONSTRUCTION. Country SHEET NO: Country Cluh q� w � STORAGE TANKS TO BE win BE REMOVED ' EXIST. PAVEMENT EXIST. MASONRY RELOCATED STRIPING TO BE PLANTER TO BE ( IN FEET ) STRIPING REMOVED 1 inch = 20 ft. KEY MAP RE-IN-KIND (NYSDOT N.T.S ITEM #619.002) REV. 1 OF 1 I