Loading...
HomeMy WebLinkAbout53181-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 53181 Date: 08/06/2026 Permission is hereby granted to: Port of Egypt Enterprs 62300 Route 25 Southold, NY 11971 To: Construct alterations to infill skylights and insulate the walls and roof of an existing commercial boat storage building as applied for. Floodplain development permit is required. Premises Located at: 62800 Route 25, Southold, NY 11971 SCTM#56.-6-4 Pursuant to application dated 06/24/2026 and approved by the Building Inspector. To expire on 08/05/2028. Contractors: Required Inspections: Fees: Commercial-Accessory Structure $11,849.00 CO Commercial $100.00 Flood Permit $150.00 Total $12,099.00 SA Building Inspector m TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 i Telephone (63t) 765-1802 Fax (631) 765-9502 lIttD :Hwww,sotit oldtowiiiiv_,go ^ Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only E PERMIT NO. 53 10 1 Building Inspector: Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an D�ar�g Mmrartrnen Owner's Authorization form(Page 2)shall be completed. `io n of Southold Date:2026.06.24 OWNER(S)OF PROPERTY: Name:The Hinckley Company scTM# i000-56.-6-4 Project Address:62800 Main Road, Southold, NY 11971 Phone#:(631) 524-6317 Email:ttyre r@ h i n ckl eyya chts.corn Mailing Address: above CONTACT PERSON: Name: Jake LaChapelle AIA Mailing Address: P.O. Box 1251, Mattituck, NY 11952 Phone#: (646) 251-5058 ]:Email: jake@lachapellearchitecture.com DESIGN PROFESSIONAL INFORMATION: Name: Jake LaChapelle AIA Mailing Address: P.O, Box 1251, Mattituck, NY 11952 Phone#: (646) 251-5058 Email: jake@lachapellearchitecture.com CONTRACTOR INFORMATION: Name: Frank Buonaiuto, North Fork Professional Services Mailing Address: P.O. Box 1614, Mattituck, NY 11952 Phone#:(917) 217-6676 Email: frank@nofops.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ligAlteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $150,000 Will the lot be re-graded? ❑Yes *No Will excess fill be removed from premises? ❑Yes WNo 1 PROPERTY INFORMATION Existing use of property: commercial Intended use of property: no Change Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to Marine 11 this property? ❑Yes ®No IF YES, PROVIDE A COPY. Check Box After ReedlU nit: The owner/contractor/design professional Is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized Inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 214AS of the New York State Penal Law. Application Submitted By(pri na w Jake LaChapelle AIA @Authorized Agent Downer Signature of Applicant: p BUNCN Date: Npta ubl'lo„State of New York STATE OF NEW YORK) No.01BU6165060 Qualified in Suffolk County SS: Commission Expires April 14,2CJ COUNTY OF } being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the (Contractor,Agent,Corporate Officer, etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this t t� d�y of t/i� z Notary Public PROPERTY OWNER AUTHORIZATION W(Where the applicant isnot the owner) I Peter Clark residing at 30 Bonnet View Dr. Jamestown Rl, 02835 do hereby authorize Jake LaChapelle to apply on my behalf to the Town of Southold Building Department for approval as described herein. Peter H. Clam p 6.27.26 "202M9 N 240&24 4'144YWw' Owner's Signature Date Peter Clark Print Owner's Name 2 isr TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631)765-1802 https://www.southoldtownny.gov Floodplain Development Permit Application PROPERTY INFORMATION: Flood Zone: AE FIRM Panel: 36103C0159H=SCTM# 1000- 56.-6-4 Address: 68200 Main Road City: Southold zip: 11971 CONTACT PERSON: Name: Jake LaChapelle AIA 777IPhone#: (631) 407-0507 Mailing Address: P.O. Box 1251, Mattituck, NY 11952 PROJECT DESCRIPTION: Insulation of roof and walls in the boat storage building SECTION A:STRUCTURAL DEVELOPMENT(CHECK ALL THAT APPLY) Type of Structure Type of Structural Activity ❑ Residential(1 to 4 families) ❑New structure ❑ Residential(more than 4 families) ❑ Demolition of existing structure ❑ Combined use ❑ Replacement of existing structure 14 Non-residential ❑ Relocation of existing structure ® Elevated ❑ Addition to existing structure ❑ Flood proofed(attach certification) N Alteration to existing structure ❑ Manufactured Home ❑ Other: ❑ Located on individual lot ❑ Located in manufactured home park SECTION B:OTHER DEVELOPMENT(CHECK ALL THAT APPLY) ❑ Clearing of trees,vegetation or debris ❑ Mining ❑ Grading Cl Drilling ❑ Dredging ❑ Connection to public utilities or services [] Paving ❑ Placement of fill material ❑ Drainage improvement(including culvert work) ❑ Roadway or bridge construction ❑ Fence or wall construction ❑Watercourse alteration (attach description) ❑ Excavation (not related to a structured development) ❑ Other development not listed(specify): By signing below I agree to the terms and conditions of this permit and certify to the best of my knowledge the information contained in this application is true and afccurate..l understand that no work may start until a permit is issued.The permit may be revoked if any false statements are made herein.if revoked,all work must cease until permit is re-Issued.Development shall not be used or occupied until a Cert.of Compliance is issued.The permit will expire if no work is commenced within one year of issuance.Other permits may be required to fulfill regulatory requirements.Applicant gives consent to local authority or representative to make reasonable inspections to verify compliance. Application Submitted By(print name): Jake LaChapelle AIA Signature of Applicant: Date: 2026/08/06 p TM �(COMcheck* Web Compliance Certifica e Project Information Energy Code: 2025 Energy Conservation Construction Code of New York State Project Title: Port of Egypt-Main Building no doors Location: Southold,New York Climate zone: 4a Project Type: Alteration Project No: 142379 Project Sub Type: Other Alteration All Electric: false Is Renewable: false Has Battery: false Has Charger: false Has Heat Pump false Construction Site: Owner/Agent: Designer/Contractor. 62800 Main Road The Hinckley Company LaChapelle Architecture PLLC Southold,New York 11971 P.O.Box 1251 Mattituck,New York 1952 (631)407-0507 jakeC@lachapellearchitecture.com Notes: Energy Credits Description Credit tl p fl B Renewable energy Number of Floors: 1 Area of Three Largest Floors: 0 Proposed Capacity: 0 Required Capacity: 0 Proposed Off-site Energy: 0 Required Off-site Energy: 0 Exception: None Building Area Description Floor Area 1-Warehouse(Warehouse):Nonresidential 28100 Report Tide:Pat of Egypt-Mdn Bulldng no doors Report Date:Jul 30,2026,11:53 AM(PDT) 1 of 11 Envelope Compliance Certificate Project Information Energy Code: 2025 Energy Conservation Construction Code of New York State Project Title: Port of Egypt-Main Building no doors Location: Southold,Now York Climate Zone: 4a Project Type: Alteration Project Sub Type: Other Alteration Construction Site: Owner/Agent: DesIgner/Contractor. 62800 Main Road The Hinckley Company LaChapelle Architecture PLLC Southold,New York 11971 P.O.Box 1251 Mattituck,Now York 1952 (01)407-0507 jake@lachapellearchitecture.cont Envelope Assemblies Gross Area or Cavity Cont. Proposed Proposed Max Max Post-Alteration Assembly Perimeter R- R- U-Factor SHGC Allowed Allowed Value Value U-Factor SHGC RoofRoof,(Bldg.Use 1- 28100 0.035 0.035 ... Warehouse](a) NORTH Ext Wall:North Wall,Heat capacity 3660 0.048 --- 0.048 1.0,[Bldg.Use 1-Warehouse](a) EAST Ext Wali:East Wall,Heat capacity 4946 ... 0.048 0.048 1.0,[Bldg.Use I-Warehouse](a) SOUTH Ext Wall:South Wall,Heat capacity 3660 0.048 0.048 1.0,[Bldg.Use 1-Warehouse](a) WEST Ext Walfflest Wall,Heat capacity 5783 0.048 0.048 1.0.[Bldg.Use 1-Warehouse](a) (a)'Other'oomponents require supporting documentation for proposed U-factors. �1111 1 1� 11 Off RIMINI! I Envelope Compliance Statement Compliance Statement The proposed envelope design represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed envelope systems have been designed to meet the 2025 Energy Conservation Construction Code of New York State requirements in COMcheckWab mply with any applicable mandatory requirements listed in the Inspection Checklist. Name-Title a Date 033931 0 OPN Report Titles Part of Egypt-Main Bullring no doors Report .. 11 ,11:53 AM(PDT) 2ofli Inspection Checklist Energy Code:2025 Energy Conservation Construction Code of New York State Requirements:71%were addressed directly in the COMCheck software Text in the"Comments/Assumptions"column is provided by the user in the COMcheck Requirements screen.For each requirement,the user certifies that a code requirement will be met and how that is documented,or that an exception is being claimed.Where compliance Is itemized in a separate table,a reference to that table is provided. Plan Review Section 6 Req.ID Plan Review Complies? Comments/Assumptions [10]2informationPlansnd/o➢n pecisufli icatent detail provide with all Does Not Location on �... �� specifications pxovlda all ❑Compliesplans/spot:A4,A5,A6,A7 com can be determined for the buiRding ❑ 1 envelope and document where exceptions to Comply the standard are claimed.The building thermal ❑Not Observable envelope isgraphicafly shown in the documents. ❑Not Applicable i C402.5.1 The vertical fenestration area<-30 percent of ❑Complies Location on plans/spec:A5 [PR5]' the gross above-grade wall area, ❑Does Not Comply ❑Not Observable ❑Not Applicable C402.5.1 The skylight area<=3 percent of the gross roof ❑Complies Location on plans/spec:A6 [PR6]1 area. ❑Does Not Comply ❑Not Observable ❑Not Applicable C402.5.2 in enclosed spaoas>2,500 f12 directly under a ❑Complies Exceptlon:Spaces where the proposed general lighting [PR9]1 roof with ceiling heights>15 ft.and used as an Does Not power densities<0.5 W/111:2. office,lobby,atrium,concourse,corridor, ❑ storage,gymnasium/exercise center, Comply convention center,automotive service, ❑Not Observable manufacturing,non-refrigeraled warehouse, retail store,distribution/sortln area, ❑Not Applicable transportation,or workshop,the following requrromentsapp?,,(a)ft daylight zone under 1 skyl➢gtits is>=hat the floor area;(b)the skylight area to d.o Ight zone Is>-3 percent with a skylight v I>=0.40,or a minimum sWight effective aperture>=1 percent. Additional Comments/Assumptions: 1 High Impact Tior 1) 2 Medium lm act Tier 2) 3 Low Impact(Tier 3 Report Tito:Pori of Egypt-Main Bullcing no doors Report Dale:Ad 30.2026.11:53 AM(PDT) 3 of 11 Footing / Foundation Inspection Section llt".m Footing I Faundstlon tttsp*Cb* Complies? commentsipssumptlons [30032.1 Exterior age, Complies„W Location on plans/spec:A7,specification 07 21 16 1 rilandscaping and equipment maintenancedi 0 Does Not Comply Q Not Observable ❑Not Applicable Additional Comments/Assumptions: High Impact(Tier 1) Medium Impact(Tier 2) Low Im ct(Tier 3) Repot Me:Port of E"-Main l3dldrg no doom Repot Dale:JLd 30.2025,11:53 AM(PDT) 4011 Framing / Rough-in Inspection Section 0 Framing Rough-in Inspection Complies? Comments/Assumptlons �Req ID I C 02.6 6 eVestibules ntrances.are installed on all buildingComplies Exception:Doors not intended to be used as a building n o n (F ]a ors have self-closing evices. ❑Does Not entrance. Comply ❑Not Observable [)Not Applicable 6402.6.1 The building,envelope contains a continuous ❑Complies Location on plans/spec:A2,A7,specification 07 2116 IFR8a1 air barrier t at is sealed in an approved Does Not manner and either constructed or tested!In an ❑ approved manner.Air barrier penetrations are Comply sealed In an approved manner, Not Observable ❑Not Applicable Additional Comments/Assumptions: High Im act(Tier 12 Medium Impact Tier 2 3 Low Impact Report71fe:Part of Egypt-Main Bulldirg no doors Report Dana Jul 30,2025,11:53 AM(PDT) 5of 11 Mechanical Rough-in Inspection Section ii Req i0 Mechanical Rough-In inspectioncomplies? ComrnentslAssutnptions �3. 7 when not itn so and meet maximumleakage �]gees lies and exhaust systems have cation on plans/slow..A2 (MEN f motorized dampers that auto matioall shut Not rates.Check gravity dampers where allowed, Comply Reference section language for operational 0 Not LibservaV'e details. j Not Applicable Additional Comments/Assumptions: t H_ Impact(Tier 1} Med'kum im act l Ier 2) 3 Low Impact(Tier 3) Report Tile:Pond EgM-MalnWIdlnitnodoors RepxGD �hd3%ZKv1;6 AM(PDT) 60$1 Rough-In Electrical Inspection Section ;r 6 Req.ID Rough-In Electrical Inspection Complies? Comments/Assumptlons mplies [ ]II7 Lowuirexnen s transformers-age C4 distribution t7m efficiencyelectric .. Om Does Notreq ply ❑Not Observable �]Not Applicable C405.8 Electric motors meet the minimum efficiency ❑Complies [EL412 requirements of Tables 0405,7(1)through C405.7(4).Elficlency verified through ❑Does Not certification sander an approved cerlificatfon Comply prrooggram or the equipment efficiency ratings ❑Not Observable sha,II be provided by motor manufacturer (where certification programs do not exist). ❑Not Applicable (C405.8. ....,. ii Now traction elevators with a rise>75 ft have ❑Complies [EL1912 a power conversion system complying with Does Not Section C405.8.1.1 through C405.8.1.3. ❑ Comply O Not Observable (]Not Applicable C405.11 ,Total voltage drop across the combination of ❑Complies [EL1]2 feeders and branch circuits<=5%' Does Not Comply ❑Not Observable ❑Not Applicable �G 10.2 Escalators and moving walks comply with ❑Complies [EL5]2 ASME A17.1/CSA B44 and have automatic controls configured to reduce speed to the ❑Does Not A �AI1 sVed palo ME1r/C AB aplicble local Not Observable code when not conveying passengers. ❑Not Applicable I C405.13 Buildings with gross conditioned floor area> ❑Complies [EL212 10,000 f12 will be equipped with a energy Does Not monitorin system in compliance with ❑ I C405,131 through C405A3.11. Comply ❑Not Observable ❑Not Applicable C40512, f 2k rooms,classrooms 0 ands'y ❑Complies C405.12.1 �enclosed offices,conference rooms,copy ❑Does Not l [ ] workstations msbr and>25%of branch circuit Comply feeders for modular furniture will have ❑Not Observable automatic receptacle control in accordance with C405.11.1. ❑Not Applicable Additional Comments/Assumptions: l i 1 High Impact(TierT1) _ 2 Medium Impact Tier 2 3 Low Impact Tier 3 Report Tltle:Port of Egypt-Mein Building no doors Report Date:Jul 30,2026,11:53 AM(PDT) 7 of 11 Insulation Inspection Section &Req.ID Insulation Inspection Complies? Comments/Assumptions C107 IN1� roof pean -vallue � Complies See evEnvelopWeeWWAssem.blies table ble for va�l..u.esInstalled with Insulation specifications reported in plans and COMcheck reports.For ❑ ~ � Does Not some ceiling systems,verification may need comply to occur during Framing Inspection. Not Observable ❑Not Applicable C402.2.6 Thermally Ineffective panel surfaces of ❑Complies Exception:Requirement does not apply. [IN5]3 sensible heating panels have insulation>=R- Does Not 1 3.5. Comply 0 Not Observable ❑Not Applicable '..[C402.2,6.............. 'Radiant paters and associated components, 0Camplies Exception:Requirement does not apply. N 2] designed for heat transfer from the panel) surfaces to the occupants or Indoor space are ❑Does Not insulated with a minimum of R-3.5. Comply i ❑Nat Observable (]Not Applicable C402.6.1.1 The air barrier design is documented as 0 Complies Location on plans/spec:A2,A7,specification 07 21 16 [IN14]1 required In Section C402.6.1.1 ❑Does Not Comply 0 Not Observable ❑Not Applicable C402.6.1.2 All sources of air leakage in the building L❑Complies Location on plans/spec:A2,A7,specification 07 21 16 [IN15]1 thermal envatope are sealed„caulked, gasketed„weather strfpped or wrapped with ❑Does Not moisture vapor-pwmeable wrapping material Comply to minimize air leakage. ❑Not Observable f j ❑Not Applicable C107[IN2]1 Installed above-grade wall insulation type and ❑Complies See the Envelope Assemblies table for values R-value consistent with insulation specifications reported in plans and ❑Does Not COMcheck reports. Comply ❑Not Observable t ❑Not Applicable C402.5.7, Stair and elevator shaft vents have motorized ❑Complies Exception:Requirement does not apply. C403.7.7 dampers that automatically close.Reference ❑Does Not [IN6]e i section C403.7.7 for operational details. Comply ❑Not Observable ❑Not Applicable C303.2 Above-grade wall insulation installed per ❑Complies Location on plans/spec:A7 [IN3]1 manufacturer's instructions. ❑Does Not Comply ❑Not Observable i 0 Not Applicable I C303.1, Roof insulation installed per manulacturer's Complies C303.1.1, instructions and is labeled with R-value or C303A.2 insulation certificate providing R-value and ❑Does Not [IN4]1 other relevant data.Blown or ured loose-fill Comply Insulation,thickness,settled l value,density, ❑Not Observable coverage area and number of bags listed on certification.Spray foam Insulation lists ❑Not Applicable installed thickness,R-value indicated on certification. C402.2.1 Roof assembly meets minimal thermal (]Compiles Location on plans/spec:A7,specification 0721 16 [IN6]1 resistance Installed between root framing or in ❑Does Not a continuous fashion on the root asse9bty as Comply stipulated,R ulroments for abrav+e deck p y insulation,mlln mum thickness„susperuded ceilings,staggered joints and skylight curios ❑Not Observable will be met. 0 Not Applicable Report Tltle:Part of Egypt-Main Building no doors Report Dale:Jul 30,2026,11:53 AM(PDT) a of 11 Section# I &Itert.ICt In4SUtation tftpeedon Complies? CornmenIstAssumptions 0402.2.2 1 Above-grade wall Insulation installed between ID Compffes _Location an planalspec A7 (IN101, wall trai�lng,Integral to or conlinuous with wall assembly or any combination of these C]Does Not Insulation rnethodolo&s.For continuous Comply insulation,joints we staggered Not Observable Not AppIlcable Additional Comments/Assumptions: 11 High Impact(Tier 1) ...... ...... urn Impact(TWr 2) ....... .........I LOW impact(Tier ReWl T10or Port d Egypi-MWn SuMno no dws Repod 11M JW M 2WS,1 t,53 AM PDT) adil Final Inspection Section# &Raq.ID Final Inspection Complies? Comments/Assumptions C401.3[Fit]' A building thermal envelope certificate is Complies supplied and completed by an approved Ej Does Not third party. Comply 0 Not Observable [j Not Applicable C402,7[I N7]3 Therrrel bridges In above grade waft at ❑complies Location on plans/spec:A7,specification 0721 16 balconies and floor decks,claddl"? 0 Does Not supports,structural beams and C,Imns and vertical fenestration comply with Comply Section C402.7. C)Not Observable C)Not Applicable C402.6.1.2.1 Recessed luminaires In thermal envelope 0 Complies Exception:Requirement does not apply. JF15)3 to limit Infiltration and be IC rated and "Does Not labeled.Sea]between interior finish and luminalre housing. Comply [)Not Observable 0 Not Applicable .1*2.P, Electrical and communication boxes are ❑Complies Location on plans/spec:A7,specification 07 21 16 C402.6,122.1 caulked,tared,gaskated or seated to air [FI6]3 barrier,Air sealed boxes in accordance Does Not with NEMA OS 4. Comply Not Observable ❑Not Applicable C402.6.2, Building thermal envelope air leakage is ❑ Complies Exception:Buildings>25,000 so If in climate zones 0-4 C402.6.2.1 tested and vadfied to be<-0 36 clm/sq it C)Does Not other than Group I and R occupancies, [F17]3 of thermal envelope area by a r third party In accordance with Comply A T 158 at equivalent approved ❑Not Observable method, ❑Not Applicable C408.1.1[F158]1 Building operallons and maintenance 0 Complies documents will be provided to the owner. 0 Does Not Documents MH cover manufactureW information,specifications programming Comply L -1 Not Observable n means of 11 ustrating Co f =buldldlng,equipment and systems are Intepeter ded to be installed 0 Not Applicable maintained,and opera C402.6.22 Dwelling unit or sleeping unit bulftling 0 Complies Exception:Requirement does not apply. [F18]3 I thermal envelop,Is air leak me tested In Does Not accordance wi ATM E77 ❑ ANSVRESNET/ICC 380,ASTM E1827 Comply or equivalent approved method. E)Not Observable ❑Not Applicable C408.322 Furnished O&M Instructions for systems C:)Complies 1[F177]3 and equipment to the building owner or designated representative. Ej Does Not Comply 0 Not Observable 0 Not Applicable C402.6A(I'll Op Doors and access openings to shafts, ❑Complies Location on plans/spec:A7,specification 08 33 23 1 chutes,stairways and elevator lobbles from conditioned space are gasketed, 0 Does Not weather-stripped or sealed, Comply 0 Not Observable Not Applicable Additional Comments/Assumptions: Ll - I-1-ligh Impact per J)_ 2 Medium Impact(Tier 2) 3 Low Impact(Tier Report Tits:Port of Egypt-Main Building no doors Report Dats'.Jul 30,2026.11:53 AM(PDT) 10otil Report Title:Port of Egypt-Main Building no doors Report Dale.,Jul 3D,2025.11:53 AM(PDT) 11 of 11 HINCKLEY YACHTS 628001D ROAD DRAWING LIST SOUTHOLD,N NY 11971 62800 MAIN ROAD A1.00 DRAWING LIST,ABBREVIATIONS, SYMBOLS, &NOTES A2.00 NOTES &ENERGY CODE COMPLIANCE S O U T H O L D, NY A3.00 SITE PLAN A4.00 GROUND FLOOR CONSTRUCTION PLAN A5.00 ROOF CONSTRUCTION PLAN SCTM#-1000-56.-6-4 A6.00 SECTION A7.00 DETAILS NOTE: DO NOT SCALE FROM DRAWINGS TAX MAP NO.1000.56.-6.4 # ISSUE/REVISION DATE .00 FILING SET 06.24.2026 .00 FILING SET UPDATE 07.30.2026 SYMBOLS REGULATORY NOTES ABBREVIATIONS DRAWN BY:J.LACHAPELLE 1. THIS APPLICATION FOR BUILDING PERMIT IS FILED WITH THE A.F.F. ABOVE FINISH FLOOR GWB GYPSUM WALL BOARD CHECKED BY:J.LACHAPELLE —LEVEL TOWN OF SOUTHOLD BUILDING DEPARTMENT, IN ALT ALTERNATE NOTE:THIS IS AN II"x17"SHEET THIRD FLOOR CONFORMANCE WITH THE TOWN CODE CHAPTER 144. APP. APPLIANCE(S) HM HOLLOW METAL DRAWINGS MAY BE PRINTED NOT TO SCALE OWINDOW EL. +31'-311 HT HEIGHT ELEVATION ABOVE 0'-0" 2. THE CONTROLLING CODE IS THE 2025 BUILDING CODE OF NEW B.O. BY OTHER HW HOT WATER LaChapelle Architecture PLLC O DOOR YORK STATE AND THE 2025 ENERGY CONSERVATION CODE OF P.O.Box 1251 NEW YORK STATE, IN COMBINATION WITH THE TOWN CODE. C/C CENTER TO CENTER MECH. MECHANICAL Mattituck,NY 11952 CLG CEILING MTL METAL 1O PARTITION TYPE 1 SHEET NUMBER ELEVATION NUMBER 3. REFERENCE HEREIN TO 'BC' SHOULD BE CONSTRUED TO MEAN CMU CONCRETE MASONRY UNIT (631)407-0507 fake@lachapellearchitecture.com A6 THE APPLICABLE BUILDING CODES OF NEW YORK STATE. CONC CONCRETE PTD PAINTED CONT. CONTINUOUS 4. THIS COMMERCIAL OCCUPANCY CLASSIFICATION IS MERCANTILE CONT'D CONTINUED RCP REFLECTED CEILING PLAN A3 1 DETAIL NUMBER GROUP M UNDER BC CHAPTER 3. ��RED ARC A4 SHEET NUMBER D.H. DOUBLE HUNG O.C. ON CENTER �5 �ACHAo yij 5. THIS STRUCTURE IS CLASSIFIED AS CONSTRUCTION TYPE II-B DIM. DIMENSION (UNPROTECTED NON-COMBUSTIBLE) UNDER BC TABLES 601 AND DIA. DIAMETER SIM. SIMILAR 705.5. DISC. DISCONTINUOUS S.S. STAINLESS STEEL c� q DWG DRAWING STL. STEEL _ J 6. TO THE BEST OF MY KNOWLEDGE THE WORK PROPOSED HEREIN IS COMPLIANT WITH ALL APPLICABLE LAWS, CODES,AND ELEC. ELECTRIC TYP. TYPICAL 30 yO STAIR DIRECTION LABELS REGULATIONS. ENG. ENGINEER �0 NO EQ. EQUAL V.I.F. VERIFY IN FIELD 00 UP DN INSPECTIONS EXIST. EXISTING W WITH FL FLOOR WRB WEATHER RESISTIVE BARRIER -m-mm-w==;�:,;0 -15wwa Via, SC SMOKE+CARBON MONOXIDE DETECTOR SPECIAL INSPECTIONS MUST BE PROVIDED IN CONFORMANCE WITH THE WD. WOOD REQUIREMENTS OF BCNYS 1704&1705. .oa.aam �� �R� artrcnraanxs.umwurramm,xxco�� �,����. ®wvmwHrxmcixxv xx uc SMOKE AND CO DETECTORS SHALL COMPLY SCOPE O F WORK DRAWING LIST, WITH UL 268,7th ADDITION FOOTING ABBREVIATIONS, ® MATCH LINE THE GENERAL INTENT OF THE WORK IS INFILL OF SKYLIGHTS AND SYMBOLS, & NOTES — — CENTER LINE PERIMETER INSULATION INSULATION OF ROOF AND WALLS IN THIS BOAT STORAGE BUILDING. ROUGH ELECTRIC NO CHANGE OF USE OR OCCUPANCY IS PROPOSED. SHEET NO: BREAK LINE INSULATION AND CAULKING ENERGY CODE COMPLIANCE FINAL A1000 SHEET 1 OF 7 GENERAL NOTES GENERAL NOTES ENERGY CODE HINCKLEY YACHTS 1. ALL WORK TO BE PERFORMED BY LICENSED TECHNICIANS TO 11. CONTRACTOR SHALL OBSERVE ALL LOCAL; STATE, AND FEDERAL 1. WORK TO COMPLY w/2025 ENERGY CONSERVATION 62800 MAIN ROAD ACCOMPLISH THE WORK AS OUTLINED IN THIS SET OF REGULATIONS CONCERNING THE REMOVAL,TRANSPORT, CONSTRUCTION CODE OF NEW YORK STATE. SOUTHOLD,NY 11971 DRAWINGS AND AS MAY BE REQUIRED BY THE WORK.ALL DISPOSAL,AND ALL OTHER ASPECTS OF HAZARDOUS MATERIALS. PLUMBING AND ELECTRICAL WORK SHALL BE CERTIFIED BY THIS INCLUDES BUT IS NOT LIMITED TO REGULATIONS THERMAL PERFORMANCE REQUIREMENTS PERSONS LICENSED IN THEIR TRADES,WHO SHALL ARRANGE PROMULGATED BY NY STATE DEPARTMENT OF HEALTH, NY STATE 2. UNFACED FIBERGLASS BATT INSULATIONBLANKET SYSTEM IS FOR AND OBTAIN INSPECTIONS AND REQUIRED SIGN-OFFS.ALL DEPARTMENT OF LABOR, NY STATE DEPARTMENT OF PROPOSED FOR WALLS AND ROOF. SYSTEM WILL BE INSTALLED WORK SHALL BE DONE CAREFULLY AND NEATLY, IN A ENVIRONMENTAL PROTECTION,AND U.S. ENVIRONMENTAL FROM INTERIOR,WITH 0.2 PERM VAPOR BARRIER APPLIED AT SYSTEMATIC MANNER.ALL WORK PERFORMED BY THE PROTECTION AGENCY,AND U.S.OCCUPATIONAL SAFETY AND INTERIOR. CONTRACTOR SHALL CONFORM TO APPLICABLE CODES, HEALTH ADMINISTRATION. CONTRACTOR SHALL ADDITIONALLY REGULATIONS,AND INDUSTRY STANDARDS. OBSERVE ALL OBLIGATIONS WITH REGARD TO WORKER TRAINING, SEE COMCHECK REPORT UNDER THIS APPLICATION. WORKPLACE SAFETY,AND PROTECTION OF PUBLIC HEALTH AND 2. THE PROPOSED SCOPE OF WORK IS A'LEVEL 2'ALTERATION SAFETY. AIR LEAKAGE REQUIREMENTS UNDER SECTION 603.AS SUCH CHAPTERS 7 AND 8 OF THE 2025 3. BUILDING IS LARGER THAN 25,000 SF AND NOT OCCUPANCY I EXISTING BUILDING CODE OF NEW YORK STATE APPLY. 12. CONTRACTOR SHALL NEITHER INTERRUPT NOR RELOCATE OR R. IN CONFORMANCE w/C402.6.2 IT THEREFORE MUST BUILDING SERVICES WITHOUT WRITTEN REQUEST TO THE OWNER COMPLY w/C402.6.2.3 WITHOUT AIR LEAKAGE TESTING. TAxMAPNo.i000Bs.sa AND RECEIPT OF WRITTEN CONSENT. REQUIREMENTS ARE: ISSUE/REVISION DATE 3. IN ADDITION TO THE REQUIREMENTS OF THE APPLICABLE a. AOR REVIEW CONSTRUCTION DOCUMENTS FOR BUILDING CODES,ALL WORK MUST CONFORM TO FIRE 13. CONTRACTOR SHALL FILE ALL NECESSARY CERTIFICATES WITH THE COMPLIANCE w. c402,6.1 .00 FILING SET 06.24.2026 DEPARTMENT REGULATIONS, UTILITY COMPANY DEPARTMENT OF BUILDINGS, PAY ALL FEES, OBTAIN ALL PERMITS b. INSPECTION OF INSTALLED AIR BARRIER FOR COMPLIANCE REQUIREMENTS,AND BEST TRADE PRACTICES. AND PROVIDE ANY AND ALL BONDS REQUIRED BY ANY CITY THROUGHOUT, PRIOR TO COVER .00 FILING SET UPDATE 07.30.2026 AGENCY IN ORDER TO DO THE WORK HEREIN DESCRIBED. c. FINAL INSPECTION REPORT BY APPROVED INSPECTION 4. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE AGENCY IDENTIFYING DEFICIENCIES PROVIDED TO OWNER FIELD PRIOR TO COMMENCING WORK,AND SHALL REPORT ANY 14. CONTRACTOR SHALL COORDINATE WITH OWNER'S SURVEYOR IN AND CONTRACTOR FOR CORRECTION DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS ADVANCE TO PROVIDE FOUNDATION SURVEY AS SOON AS ANY 4. PER C402.6.2.3.1 AIR BARRIER SHALL HAVE AIR PERMEABILITY OF DRAWN BY:1.LACHAPELLE TO THE ARCHITECT. NEW FOOTING CONCRETE IS PLACED, AND SUBMIT TO < 0.004 cfm/ft2 (0.02 L/s x m2) CHECKED BY.J.LACHAPELLE SOUTHOLD BUILDING DEPARTMENT. 5. PER TABLE C402.6.3 ROLLING DOORS SHALL HAVE AIR LEAKAGE NOTE:THIS IS AN II"x17"SHEET 5. CONTRACTOR SHALL TAKE THEIR OWN DIMENSIONS AND FIELD RATE OF 1 cfm/ft2 (5.08 L/s x m2) OR 1.3 cfm/ft2(6.60 L/s x m2) IF DRAWINGS MAY BE PRINTED NOT TO SCALE VERIFY ALL DATA CONTAINED HEREIN. THE DIMENSIONAL DATA 15. PRIOR TO COMMENCING OPERATIONS ON SITE THE HIGH-SPEED MOTORIZED ROLLING DOOR CONTAINED IN THIS DRAWING SET ARE FOR INFORMATION CONTRACTOR SHALL PROVIDE BOTH OWNER AND ARCHITECT 6. PROVIDE DAMPERS AT ALL OUTDOOR AIR INTAKES IN LaChapelle Architecture PLLC ONLY.THE BUILDING IS NOT SQUARE OR PLUMB SO VARIATION 'ACORD' INSURANCE FORM LISTING THE FOLLOWING PARTIES AS CONFORMANCE w/C402.6.5 P.O.Box 1251 EXISTS IN THE DIMENSIONS OF THE EXISTING BUILDING.AS A ADDITIONALLY INSURED: Mattituck,NY 11952 RESULT DIMENSIONS OF NEW CONSTRUCTION MAY VARY FROM THE HINCKLEY COMPANY (631)407-0507 jake@lachapellearchitecture.com THOSE SHOWN. CONTRACTOR SHALL NOTIFY ARCHITECT OF LACHAPELLE ARCHITECTURE PLLC DISCREPANCIES AS THEY ARISE. THE CONTRACTOR MAY NOT BEGIN SITE OPERATIONS OF ANY KIND UNTIL THE ABOVE IS PROVIDED. 6. MINOR DETAILS NOT SHOWN OR SPECIFIED, BUT NECESSARY czeD ARC FOR PROPER CONSTRUCTION OF ANY PART OF THE WORK 16. LACHAPELLE ARCHITECTURE PLLC HAS BEEN RETAINED BY THE ��� q�pCHA him SHALL BE INCLUDED AS IF THEY WERE INDICATED IN THE OWNER TO PERFORM (2) SITE VISITS DURING CONSTRUCTION DRAWINGS. PHASE ONLY, SOLELY TO IDENTIFY SUBSTANTIAL DEVIATIONS FROM THE CONTRACT DOCUMENTS. LACHAPELLE ARCHITECTURE 7. CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES PLLC IS NOT RESPONSIBLE FOR INTERPRETING THE INTENT OF THE WITH REQUIREMENTS OF LOCAL AUTHORITIES AND OWNER. CONSTRUCTION DOCUMENTS DURING CONSTRUCTION PHASE, (s� INCLUDING MAKING MODIFICATIONS AS MAY BE NECESSARY A o ss� �O 8. PROPOSED GWB FINISHES MUST COMPLY WITH BC CHAPTER 8. DURING THE CONSTRUCTION PHASE. LACHAPELLE ARCHITECTURE �c OF N�� TAPED, PRIMED,AND PAINTED GWB IS ALLOWED UNDER BC 803 IS NO LONGER LIABLE FOR WORK WHERE CHANGES HAVE BEEN AND QUALIFIES AS A CLASS-A MATERIAL WITH FLAME SPREAD MADE TO THE WORK SUBSEQUENT TO PREPARATION OF THESE INDEX LESS THAN 25 AND SMOKE-DEVELOPED INDEX BELOW DOCUMENTS. 450. THIS EXCEEDS THE REQUIREMENTS OF BC TABLE 803.13 FOR THIS OCCUPANCY. 17. THE CONTRACTOR SHALL ENSURE THE STRUCTURAL STABILITY OF ��°� 6 ALL AREAS OF THE WORK THROUGHOUT OPERATIONS.THE 9. CONTRACTOR TO SCHEDULE AND PROVIDE ACCESS REQUIRED CONTRACTOR SHALL DO SO BY WHATEVER MEANS HE DEEMS FOR ALL INSPECTIONS.WORK MUST REMAIN ACCESSIBLE AND ARE NECESSARY, INCLUDING BUT NOT LIMITED TO RETAINING A (VOTES EXPOSED UNTIL INSPECTED AND ACCEPTED IN WRITING BY THE LICENSED ENGINEER AT THE CONTRACTOR'S EXPENSE TO & ENERGY CODE INSPECTOR. OVERSEE AND ADVISE ON THE WORK. COMPLIANCE 10. CONTRACTOR MUST COMPLY WITH ALL BUILDING DEPARTMENT RULES OF OPERATION (SUCH AS HOURS OF ACTIVITY) AND SHEET NO: INSURANCE REQUIREMENTS. A2v00 SHEET 2 OF 7 , MAIN HINCKLEY OLD M ROAD .� y ,F YACHTS xfi I: .• .. V/.1 59 � Ar! 62800 MAIN R'° ' ;,. .: SO THOL Y 119D71 r , , , { 'J r. K°"h ,. ''+>•°i1.' SUBJECT BUILDING-6MM MAIN ROAD TAX MAP N0.1000-56:6-4 # ISSUE/ 'Y UE/REVISION DATE o NAII- � �•,,' �.,rr a;r� ,� - �'w rt " �'�' ,, C � .00 FILING SET 06.24.2026 { .00 FILING SET UPDATE 07.30.2026 Y me AR.IN LDDISGIA s DRAWN BY.1.LACHAPELLE CHECKED BY:J.LACHAPELLE - NOTE:THIS IS AN II"x 17"SHEET DRAWINGS MAY BE PRINTED NOT TO SCALE LaChapelle Architecture PLLC P.O.Box 1251 �;< E _ � •� �`. Mattituck,NY 11952 .: 41ilk " 4 (631)407-0507 jake@lachapellearchitecture.com 4 � IY li i I ED If r -s —t T �J 03393� # O J. wr IL _ Ii �I n + Ir �.� I �.�i,� t C, 7p we ow,ran:nrx iu-�ai.mir�raeemxienouw�TMernv�',miw new�ors� �: i;, usx ¢xur¢c.zo�,vvamc rr � ,. '�•' . i• �e ' '`. ~ � umrtA ru+r vmw:rtranarrq Gobi ucwrtcrvv vuc G 4 , •' . . :. , . r '� 'i � 'y� ®COMMGM302i l:LMf.PCLL[nF`CN�I[GIIiS RIL iR S s M SITE PLAN SHEET NO: „F ! low ` ,,NORT 0T SCALE:,, A3mOO Y SHEET 3 OF 7 HINCKLEY YACHTS 62800 MAIN ROAD � ,o SOUTHOLD,NY 11971 IY Y IY Y 22&-6" IY Y 153'8" 41'-T 25'-7' 251-0" 25'-0" 25'-D" 25-T 251-0" 25'-W I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I TAX MAP NO.3.000-56:6-4 I I I I I I I I I I I I I I I I I I I # ISSUE/REVISION DATE I I I I I I I I I I I .00 FILING SET 06.24.2026 I I I I I I I I I .00 FILING SET UPDATE 07.30.2026 - I I I I I I I I I I DRAWN BY:J.LACHAPELLE I I I I I I I I I I CHECKED BY.,J.LACHAPELLE NOTE:THIS I I I I I I I I I I IS DRAWINGS MAY BE PRINTED NOT TO SCALE a, I I I I I I I I I I I I I I I I I I I I LaChapelle Architecture PLLC I I I I I I I I I I P.O.Box 1251 I I I I I I I I I Mattituck,NY 11952 I I I I I I I I (631)407-0507 jake@lachapellearchitecture.com I I I I I I I I I I I I I I I I I I I I RED qh, I i I i I i I I I �•5 ��_ACNgoCy% I I I I I I I I I I 9�F �ssso I I I I I I I I I I OF N E`� I I I I I I I I I I I I I I I I I I I I TXb aMW1NS bANar3RNMENlMaWIIrFAN of 4RW41LF . - ANCNRECNNE RALaFmwwvO{N'1HIMFAiI¢PpllfR{OaxMiCXRb PRPAgEa b a1FA NOGHONGF9,KT[PA90Na,OR PU�p MAT 6¢MN➢E[%CER 6Y 4aW➢ELLE I I I I I I I I I I ui�ewiEarvaEauamma bvaxmra MAvxara aromEa PAarRs roamxmwwEcn. roNAnanroxmrws raamermNEr,raanEs,oarwcawvanonwrras ram Tar ,wimwrrxewwtrrnwrboRa ucrwEUE Aaarm�rnaw.c I I GROUND FLOOR 25'.9'��25'-0" 25 -0 5'-0''-0" a� 25' ' 2 --25'-0" 25'4"�' 25'-0" ��26'-4 229'�" 3'- { CONSTRUCTION RUCT'oN I III.. 10 PLAN b b b b b b E) E) SHEET NO: PROJECT OR ® �®® 1 GROUND FLOOR CONSTRUCTION PLAN NORTH NORTH P—! O SCALE: 1" = 20' 0" 9.7°) SHEET 4 OF 7 SCOPE NOTES(BASIS FOR BIDDING): �,I Y L�'� 1. REPLACE OR REPAIR STEEL PURLINS PER ENGINEER H ! !'S REPORT 2.PROVIDE ADDITIONAL STEEL SHORING PER ENGINEER'S DETAILS MEMBRANE ROOF TO REMAIN YACHTS ��® ®��q 3.REMOVE CORRUGATED METAL WALL PANELS AND REPLACE PER SPECIFICATION,ALTERNATING � �M9 J BAYS PER ENGINEER INSTRUCTION 4.PROVIDE NEW INSULATING SYSTEM AT ROOF AND WALLS PER DETAILS AND SPECIFICATION 51 PROVIDE NEWGUTTERS AND LEADERS TO ORYWELLS I RAINGARDENS PROTECT�EFLASH EXISTING 62800 MAIN ROAD a PRevIGENEW+ ATeRsflp�seNNESTreNs— ^ n 70 SOUTHOLD,NY 11971 Y Y IY Y 228'-0^ 4I `Lr T IY 153'-8" 41'-3" 26-T' 25'-0" 26-0" 25'-0" 25'-0" 25'-0" 25'-0" — — —.-r.—.—.—.—.—' — —'— '—'— — —.—.—.—.— r___T---T---T---T---T---T___T---T---T---T---T___T___T___T___T___T__T___T___ ___T__T___T___T__T___T___T---T__T__T---T---T---T---T--- T___T___T__T___T__T___T___1 I I I r I I ; I LIQUID APPLIED ROOF TO R MAIN I + ----� - ---+�-+--+- +---� - ---�- +-- --+---+- +---1- 1- 1 -+-! --+---+ 1--- --- ---1--+�--+--+— -�--�-- -- I I I !C i�I_i1___1--- I % rIL L! _1 Y — T I SINGLE STOY ! I I I I 'V _N TAX MAP N0.1000.56.-6-4 I I II !I II SINGLESTORY- t--+---+---+---+- II _ _ # ISSUE/REVISION DATE+ t I+ +I---+---t---+---+---+---+---+ +---+---t -+--+---+--- --+---+---+--+---+--- -+--- -- '-- '--- PROTECT AND FLASH I I r i EXISTING I I I FLUE U I i r I I REPLACE TTER AN P I I I r I I I I ------' -� -�--� -1-1---�--�--1--� �-_�--�--�--}--� -�- L- �--1--� -1 -' --�- �- i-J �- �--' LEADER) KIND .00 FILING SET 06.24.2026 rt -^- --T---T-^T---T---T---T---T---T---T---T-JT---T---T---T---T---T---T--- ---T'--T--1T--^T---1-^-T-^^T- T---T-^'T^-'T-^-� ---T--- - --- ---T---T---T---Y---T--T^^^T-^^T'--T--T"-T-^-T-^^ T T T T T T---r---T---T^--T^^^T---, .00 FILING SET UPDATE 07.30.2026 � T i ( ! 11 ! ! t i I -t-f 1 ! '� �! r l I I ! IT I I it 1 I I 1 T it I il ' TI I I I ; ; ; 1 1 I I I l l r l I I I I I I l l r I I I I I I I 1 { I I I ! I DRAWN BY:J.LACHAPELLE I I I I I I I I I I I I I r l l I l r l l l r I I i I I I I I I I p I -_- CHECKED 8Y:J.LACHAPELLE { i 1 1 _ -- _ _ r r r ! I I I I ; I I I I I r I I I I I I I I --- 1--1- �- '--� -�-- 1---1---�---1- -' 1- -�- --�-- -' L- 1--'- 1 -1- 1- 1---1- 1 1-1- 1 _ 1•--1---1--- --r } .y - ---1-- ---1---1--1---'- 1---1---1---1---1---1---1--t` 1 1 -1--1---1---1---J U I I ? -- --; -- --, --, I- ' `-'-, -- I 'p' NOTE.THIS IS AN 11 x 17"SHEET r DRAWINGS MAY BE PRINTED NOT TO SCALE S, , r-_-_-_, _r f` I! ! 1I ! %Ti11 _-_--_1II•-___T�III ___iiIII -_-_-_T-_-_-_T---_,� i { T IiI b LaCha pelle Archit ectu re PLLCr--- 7---T T-- L;! T L j a__Lr==1=_J __I___------ __T___T -__ = _ _ P.O.Box 1251 TT Matttuck NY 11952 ___1__ 0 07 jake@lachapellearchitecture.com m_ r1___ fi i-- - L I I I I I { I 1 ' i ---1---1--- ___1--- ---1---1 ---i--; �631>407 { ABC MG 0'A° I I I I I I I _ _I ___ --- -- I ! I B � AB -T___ ___T___T__T---T---T__T---T___T__T---T___T__T---T---T__T___T___T___T___T___T--- T--- T--- T___T___T__T___1 r__T___T___T_ T __T___T___T__T___T___T__T___T__T___T___T__T___T---T---T---T__T---T---1 "✓� oEr— L----� I I' i t III ! I I I I I i I I I I I I I I l r l l l l I I r l l I l r l I I I I I I I I I I I I I 2 I r I I I I r I I i t l + t t i i i ';--- I r T--+ + + t + i + +-l. -- + --- - 4 F-ED I I I I r i l I I I I I I I I I I I I I I I I I ) I I I I I I I I I I I I I I I I r I i1r1i! lI l lII!i l! lii1I'I r!!tt ;iI ;I ;_Ii6 _'t-_;-1,;\l__ _1Il___11Il1I -'_;—_if_7111IlIII __ �! TI)I i1 I)I' --r r ___1___1 11___1___1___ 1__ ---___ L___1__ -T_ 11___1___1___1___ �--'I;IIIIi � IJ I _ Al ` I ' J , J'` 1---J ! ''' i - �- --- I ; L--- ' h J !` J J1I�_,' I ;I L__- _ J L__\L--y -� %_! ! L__ L___J T I---___T r--� _T___T___TT---,III� y I!III Nt7L ,X �-� 1 1 I I I I--- + ! i t I 1 i I 1 i I ----------------; t ---+ ---+--- +-- --+- +---+---+---+---+-- -+---+---+---+------+---+---+ +---+---+---+---+---+---t---+t-+ - OPN1 E+---+- +--- - ---+--- t -i -- I--- I . �- I`NA �I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I i I ! i I I ; { ; I i rx°°nnmlmnaxaumum:Inorsmv�caowEmr+fnrneaaaumorucxuule I I I { I I I I I I ! ; axrurEcmrePueacaw+aesofw�mrnixEvaorECEfanwxlcxlruPwralrcols I I r ) I I I r I I I I r I I l I l I ' I I I I __J._ r L r 1 I I I I IyCNFl CHNiGf3 aLIEPAn WOR OfIY110u5 M4r BEhu°E F%CER6Y IACNMEIlE I r I I I -__1_--1--_1__1_ __1___1_ 1___1___J._ J.___J __1__' __1__1___1--_1--1-- _1�_ --1___1___1__J 1 wlnmu'oNawllw.,.urxoleeuuUar o.lan PPPntl FOPmwIi PRWttfS, I I I I I I I I I fORP°OwOUI°11A5 PADI[LT Br°IXERPagfltl.Oq iORCOMPLEtMNaFTHRiIm1ECr0Y o- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —° — — — — — — n OIN]tPa9nfs,VTBWfdEHwiIENCON9¢Mof lacllafeucalsxrtEervuPuc �^J ®wvrwexraozs lJexaveusarawn:nunz Pue Ll ROOF 253' 25'-0" 25'-0" 25 25''4r 25'-0" 25'-0° 25'-0° 28' 4 z2e'-0 CONSTRUCTION NEW GUTTERS AND PLAN / (D LEADERS � � I0 0 0 llJ• o PR STORE ALL REMOVE CURROGATED OTECTANDFIASH IIIJJJ REMOVE SHEET NO: PHOTOVOLTAJC PANELS ANDD SUPPORT POLYCARBONATE SKYLIGHT AND EXISTING FLUE PROJECT TRUE O ROOF CONSTRUCTION PLAN FRAMES,CU BRACMOVEKETS ETSCON TO D ANDECK REPLACING PERARCH1TDALUMINUM WRING;CUT BRACKETS TO DECK SHEETINGpERARCHITECT'BDETAIL NORTH NORTH SCALE: 1" = 20'-0" (19 7°> A5mOO SHEET 5 OF 7 HINCKLEY YACHTS 62800 MAIN ROAD SOUTHOLD,NY 1:1971 - I PROVIDE NEW I �' INSULATING SYSTEM AT WALLS PER DETAILS AND SPECIFICATION PURLIN SPACING IS APPROXIMATE- Q 1'26 2!3'2'•3° PROTECT EXISTING VERIFY IN FIELD 12 LATERAL BRACING 4'-t0' 4,,10. q-10' 4 THROUGHOUT 10 4-110° 4104'•10' 4' 4 10 4-10' 4'l0" 4'-10' ° ' 4 10• q-p.I2F•0° I .. REMOVE EXISTING CORRUGATED I 1• $•1' S'-1• $'-1e $,1' Z�.71• METAL SIDING,REPLACE WITH NEW EXISTING B'x 3"x?e Z•GIRT STRUCTURAL PURLINS TAX MAP NO.1000-56.-6.4 EXISTING BUTLER FRAMES REPAIR OR REPLACE STRUCTURAL I I PURLINS PER ENGINEER'S REPORT ISSUE/REVISION DATE PROTECT EXISTING LATERAL BRACING I I '§v .00 FILING SET 06.24.2026 PROVIDE NEW v INSULATING SYSTEM AT I I 1? WALLS PER DETAILS AND b I I .00 FILING SEI'UPDATE 07.30.2026 SPECIFICATION o - loop-0" l35'�p' DRAWN BY:J.LACHAPELLE MAIN BqILDING I EAST BAY CHECKED BY:J.LACHAPELLE bV bD NOTE:THIS IS AN 11"x 17"SHEET O EAST-WEST SECTION DRAWINGS MAY BE PRINTED NOT TO SCALE- SCALE: 1" = 20'-0" LaChapelle Architecture PLLC P.O.Box 1251 Mattituck,NY 11952 (631)407-0507 jake@lachapellearchitecture.com I I I I I I I I I ED Az4 LAcPROTECT EXISTING liq LATERAL BRACING I I I I I 1 ll\ 03 N I I I I I t I I 0F ��O I I I I I I I I a M6OMw1N46AN4vsTPUMUROrsEFnCEw DPEFWNETXE RWPEPlY0i L4]NFELLE pREHfIECNPEFLLC PEOMDIFSUOf 1`A siH TIR PpOJF•ErOPWNiCNRUPFIDPRE015 I I I I I I I I E��P,E4Na�N��E,,P�EEP,"o�.�P"E�P,N„YEEm,PEEEPEPTPE�E�PEUE APC��ONPE NC.1N6 duwlNO!MY NOT B[Uo5E0 8Y OMEP PAATIE4 rOP OR1Ot PRO1 CCES, OPIONTOlHS PPOIECt6Y0TXEPPePP .oP rOPCOMTETMNMTH4PPOIECi OY OIHEPPUOIEE.wRNWTTPEwgPR1Gp5EM 14EMnPfllE0.PCNPECNPF PLK ' 0 WPYPkM20281P1:W➢ELLE4RHIiEOEYPf PLIC I I I I I I I I 228'-0" — SECTIONS MAIN BUILDING - I1 I I II II II II II II I SHEET NO: O SCALE:NORTH-SOUTH 1 ZOOSECTION A ®®® SHEET 6 OF 7 HINCKLEY EXISTING FLUID APPLIED MEMBRANE YACHTS EXISTING CURR.METAL PURLIN SPACING IS 62800 MAIN ROAD ROOFING APPROXIMATE- SOUTHOLD,NY 11971 EXISTING 8"x 3"x 16'Z-GIRT VERIFY IN FIELD STRUCTURAL PURLINS THROUGHOUT EXISTING BUTLER FRAME n 4'-10° REMOVE EXISTING CORRUGATED METAL TAX MAP NO.1000-56.-" 1 SIDING, REPLACE J` WITH NEW i I #i ISSUE/REVISION DATE PROPOSED BATT ; INSULATION&METAL .00 FILING SET 06.24.2026 SEAL OR TAPE VAPOR ------ STRAPPING SYSTEM w EXISTING 8"x 3"x BARRIER PER R 16 Z-GIRT 00 FILING SET UPDATE 07.30.2026 SPECIFICATION AT ALL STRUCTURAL PENETRATIONS FOR PURLINS CONDUIT, HANGERS, EXISTING FIRE SPRINKLER ------------- DRAWN BY:J.LACHAPELLE CHECKED BY:J.LACHAPELLE ELECTRICAL BO SYSTEM THROUGHOUT ETC. EXISTING BUTLER NOTE:THIS IS AN 11"X 17"SHEET 1 TYPICAL ROOF DETAIL FRAMES DRAWINGS MAY BE PRINTED NOT TO SCALE PROVIDE NEW SCALE: 1 1/2" = T-0" E0 HIGH-DENSITY LaChapelle Architecture PLLC POLYETHYLENE VAPOR BARRIER AT INTERIOR OF P.O.Box 1251 Z-GIRT PURLINS Mattituck,NY 11952 (631)407-0507 jake@lachapellearchitecture.com 0 PROTECT EXISTING REPLACE CURR. LATERAL BRACING ARGy METAL SIDING PROPOSED BATT ���� �� CH,q PROVIDE CONT. INSULATION&METAL THERMAL BREAK AT STRAPPING SYSTEM W/ PURLINS VAPOR BARRIER o v N�� 03 �0� PROVIDE NEW F O F N c� EXTERIOR INTERIOR INSULATING SYSTEM AT WALLS PER EXISTING 8"x 3"x DETAILS AND SPECIFICATION _ r1RCMRCNp F11C NE0l3mLL36°iW11EEN¢RME RMIER igiYIIICN""PPmMf°IS Ft0.CN1E0.N MW°EY.X"NPT°Nx,ON0.FLETONSMAYBCMAce E%°F➢f BY IACNAPfll1 16 - IRT O ARCN °NMP LMRDMW3°MAY NOTBl NSDe°X FPAN°SPoPO XRPN°EC S, i0 O1NCN�PFSIMiIUVt T1EYYlFRRNPWNSCF3AT D!{ACXfANMIME N 'LLC.� STRUCTURAL � ®C°PfPo°Mx°x61AClWFl1PAPW1EClUPEPLID PURLINS — i SEAL OR TAPE VAPOR EXISTING BUTLER i BARRIER PER DETAILS FRAME ____ SPECIFICATION AT ALL PENETRATIONS FOR CONDUIT, ELECTRICAL BOXES, ETC. SHEET NO: TYPICO SCALEA1 EXTERIOR 10 WALL DETAIL O STYPCIAL CALE: 1/4ECT100N @BUILDING ENVELOPE AT ® SHEET 7 OF 7 53 S f Ass sot s AMENDM NT HINCKLEY DRAWINGLIST �" �'- " t 62800 MAIN ROAD 62800 MAIN ROAD 6 SOUTHOLD,NY 11971 A1.02 DRAWING LIST,ABBREVIATIONS, SYMBOLS, & NOTES CU L° A2.01 NOTES &ENERGY CODE COMPLIANCE S O U T H O L D N Y A3.00 SITE PLAN A4.00 GROUND FLOOR CONSTRUCTION PLAN A5.02 ROOF CONSTRUCTION PLAN ?cdv n c-> 01 SECTION SCTM#-1000-56.-6-4 A6. TAX MAP N0.1000-56.-6.4 A7.02 ELEVATIONS A8.02 ELEVATIONS # ISSUE/REVISION DATE A9.02 DETAILS .00 PERMITSET 08.03.2026 NOTE: DO NOT SCALE FROM DRAWINGS .0i AMENDMENTI 08.19.2026 .02 AMENDMENT2 09.01.2026 SYMBOLS REGULATORY NOTES ABBREVIATIONS DRAWN BY:J.LACHAPELLE 1. THIS APPLICATION FOR BUILDING PERMIT IS FILED WITH THE A.F.F. ABOVE FINISH FLOOR GWB GYPSUM WALL BOARD CHECKED BY:J.LACHAPELLE LEVEL TOWN OF SOUTHOLD BUILDING DEPARTMENT, IN ALT ALTERNATE NOTE:THIS IS AN II"x17"SHEET THIRD FLOOR CONFORMANCE WITH THE TOWN CODE CHAPTER 144. APP. APPLIANCE(S) HM HOLLOW METAL DRAWINGS MAY BE PRINTED NOT TO SCALE OWINDOW EL, +31'-3^ HT HEIGHT ELEVATION ABOVE 0'-0' 2. THE CONTROLLING CODE IS THE 2025 BUILDING CODE OF NEW B.O. BY OTHER HW HOT WATER LaChapelle Architecture PLLC O DOOR YORK STATE AND THE 2025 ENERGY CONSERVATION CODE OF P.O.Box 1251 NEW YORK STATE, IN COMBINATION WITH THE TOWN CODE. C/C CENTER TO CENTER MECH. MECHANICAL Mattituck,NY 11952 ELEVATION NUMBER CLG CEILING MTL METAL 1O PARTITION TYPE 1 SHEET NUMBER 3. REFERENCE HEREIN TO 'BC' SHOULD BE CONSTRUED TO MEAN CMU CONCRETE MASONRY UNIT (631)407-0507 jake�lachapellearchitecture.com A6 THE APPLICABLE BUILDING CODES OF NEW YORK STATE. CONC CONCRETE PTD PAINTED CONT. CONTINUOUS 1 4. THIS COMMERCIAL OCCUPANCY CLASSIFICATION IS MERCANTILE CONT'D CONTINUED RCP REFLECTED CEILING PLAN A3 rlk-\Ik DETAIL NUMBER GROUP M UNDER BC CHAPTER 3. ��ERED qR A4 SHEET NUMBER D.H. DOUBLE HUNG O.C. ON CENTER �C�� �e LAC Cyr 5. THIS STRUCTURE IS CLASSIFIED AS CONSTRUCTION TYPE II-B DIM. DIMENSION F� A . (UNPROTECTED NON-COMBUSTIBLE) UNDER BC TABLES 601 AND DIA. DIAMETER SIM. SIMILAR _m 705.5. DISC. DISCONTINUOUS S.S. STAINLESS STEEL DWG DRAWING STL. STEEL UJ r _ J 6. TO THE BEST OF MY KNOWLEDGE THE WORK PROPOSED HEREIN y y IS COMPLIANT WITH ALL APPLICABLE LAWS, CODES,AND ELEC. ELECTRIC TYP. TYPICAL �� 0330 Onc STAIR DIRECTION LABELS REGULATIONS. ENG. ENGINEER O�,N E\N EQ. EQUAL V.I.F. VERIFY IN FIELD U00 P DN INSPECTIONS EXIST. EXISTING W/ WITH FL FLOOR WRB WEATHER RESISTIVE BARRIER SC SMOKE+CARBON MONOXIDE DETECTOR SPECIAL INSPECTIONS MUST BE PROVIDED IN CONFORMANCE WITH THE °TM"o ""u��""" WD. WOODwM°.,.q a� �b� TM REQUIREMENTS OF BCNYS 1704&1705. ®n"� "u'�«'�­rt�.- "°"` SMOKE AND CO DETECTORS SHALL COMPLY SCOPE O F WORK DRAWING LIST, WITH UL 268,7th ADDITION ABBREVIATIONS, FGUNDATIGN— MATCH LINE THE GENERAL INTENT OF THE WORK IS INFILL OF SKYLIGHTS AND SYMBOLS, & NOTES CENTER LINE PERIMETER INSULATION INSULATION OF ROOF AND WALLS IN THIS BOAT STORAGE BUILDING. ROUGH ELECTRIC NO CHANGE OF USE OR OCCUPANCY IS PROPOSED. SHEET NO: BREAK LINE INSULATION AND CAULKING ENERGY CODE COMPLIANCE FINAL A1,02 SHEET 1 OF 9 a 90O_OTES(BASIS FORBIDDING): F'I I N C I'(L EY 1. REPLACE OR REPAIR STEEL PURLINS PER ENGINEER'S REPORT 2.PROVIDE ADDITIONAL STEEL SHORING PER ENGINEERS DETAILS 3.REMOVE CORRUGATED METAL WALL PANELS AND REPLACE PER SPECIFICATION,ALTERNATING MEMBRANE ROOF TO REMAIN YACHTS BAY.PER ENGINEER INSTRUCTION D/'�A S 4.PROVIDE NEW INSULATING SYSTEM AT ROOF AND WALLS PER DETAILS AND SPECIFICATION S. PROVIDE NEW GUTTERS AND LEADERS TO DRYWELLS I RAINGARDENS PROTECT AND FLASH )pi PANELS SEE AB FOR y 12Szlm R)o EXISTING FLUE NCTIONAL' SKYUGHTSCOPE 6`2800 MAIN ROAD � E � D S9UTHOLD,NY 11971 22V-r 153'-0' 41'-3" 25'-T 8'-0' 11-4 W-3- 25-0" 25-0` W-0•�' 25-0' 25-0' 250' - - - -- -- -- -- -- -- -- -- - - --- -- -- --- -- - - -- -- --- --- - -- -- -- -- -- -I I IT TI � � T TIT T 'I -; ;-- 1I I I I I 1 1 1 1 1 1 1 I I I I 1 1 1 1 1 I I I I IIII I IIIIIII 1 1 11 IIIII I I 1 _ 1 I TAX MAP N0.1000 58.8 4 I I I I I I 1 LIQUID APPLIED ROOF TO REMAIN I I I 1 1 I I 1 S---n ---JI ---i ! ! ! # ISSUE/REVISION DATE t r1i I I ; I I I I I I i STORY• ! " i ^ I /�, , I_,J._ /\ , /`, i %1 r__('i___.`_'_J Ir ! i LI 1 J I ! SINGLE ! ! I I I/ I I I STO .00 PERMIT SET 08.03.2026 ='+S" ;, i/�" it�I !I\! ! I/ ! T r---T---T---T--T---T---T- --- --- --- --- --- --- — --- -- -- --- --- --- ---i--- --- --- --- --T---T--`T_-T--'T-__T--- --- --- --- --- --- -- --- --- --- --- --- 1 01 AMENDMENTI 08.19.2026 I I I I I I I 1 I I I I I i i i i i i i i i i t i i i i I SINGLE STORY 1 I I I I I I I I I I I I I I 1 I I I 1 I I I I I i +--+---+---+---+--}+---+---+---+---+---+---+---+;--+---+---+---+---+---+---+---{---+---+---F---+---+---+---+�-i----+---+---+---+---+---+---+}--+---+---+---+---+---+---i i I ! 02 AMENDMENT2 09.01.2028 1 I I I I i 1 PROTECT AND FLASH 1 EXISTING FLUE REPLACE 3UTTER AND 1 1 I I I 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 1 I I I I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 i i i i I i I I I I LEADER 11 KIND 1 I I i 1 Ii I1C1___TI11___TI.III__TIII___III III III i l ;I I1I I1I II I1 1 T--- T--- T__rT___T___ T___T___T_--T---T1T _ ___ ___!___ ___ ___T-_—i ___T_--T___T___T___T___T__ri,'---T--- ! T ___ _--I!---T!---T---T---T---T---4!---T--jl;----,---T -T---T--T---T---Ti-rt-T---T---T---T---T---T---;---,I---T---T---T---TI---;---T-- TII - I - - - ---t-- --- - - - -- -- - 11 IIII 111111 IIIIIII IIIIIII IIII I IIIIII IIIIII IIIIIII IIIIIII I I I I I I I 1 1 I 1 1 1 1 1 1 1 1 1 1 I I I I I 11 1 1 1 1 1 1 1 1 1 1 1 I I I I I I I I I I I I I DRAWN BY:J.LACHAPELLE I I 1 1 1 1 1 I I I 1 i i i I I I I I I 1 1 I I I I I 1 I I I I 1 I I I I I ___ ___ ___ ___ ___ __ ___ ___ ___ ___ ___ ___ ___ __ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ _ ___ ___ ___ ___ ___ ___ ___ __ ___ ___ ___ __ ___ _ ___ ___ ___ ___ ___ __ ___ ___ __......___ ___ ___ ___ ___ ___ ___ ___ ___ ___ CHECKED BY:J.IACHAPELLE 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 1 I I I I I I I I I I I �IEv `---1---i----`---i---i---J-- `---i---i---J'---J'---J,_--J'---•' --ir--J----i---i---i---i---i---}---J'---J'---'----i---l---i---i---i---i--,i---J'---J `---J---- ---i---J----J'---i---i---i---L-- --i---i--,i---'----�'---J'----`---J----''---J'---J'---J'---i---i---i----`---i---i---J'---i---i---J •ti NOTE:THIS IS AN 11"x 17"SHEET --- ---,r --- I ---,I --- --- ---, �1 r ---7 I r--- ---, -- ---, ! " DRAWINGS MAYBE PRINTED NOT TO SCALE r -- !\ ! I''� ;tij i I i %i i ,%! `\ti '`\ -T-, `r � I - ! Ir-T i ! I - I I -- IVI I ! P 5 I----T T � I I I ! { I %� ; i i �, ;, ; ; A T- T 1 I I I -� I; ! !;,I �;'�; I ! !%',I I/' E I j;\i i/ !I ; i i i ! i "`,! li\� li I%"'\ I ! '`! 3 ! !/`` !rr v I LaCha elle Architecture r I I ,; I ,i r ,; \ i ;j'`; ;`,� PLLC ! Il_�I �- ! �, Ir Ic-,I --- /-- ---J I I� �/-s! ! -- I L- ! !I'-- ---J I I�--J P L___1___J L___J.___J L__1___J ' __1___J ___ __ L-__1_-_J ___ ___ ' J ___l___J 1_ ` T TII J - Box1251 TC__ _ ___ ___ ___ ___ ___ ___T___T___T___T___T___T___T_�_ ! ! I! I l I l ! Mattituuck,NY 11952 I I I I I I I I 1 I I I I 1 1 --_----- ---------- � y 07-0507 I I I I I I I I ;.__�___r ---------- L L __J 1___1___1___1___1___i___1___1 jake@lachapellearchitecture.com I I EXISTING VENTILATION FAN . — ! RIDGELWE A 31Y-0" ___ __ ___ ___ ___ ___ __ _ -- _ ___ ___ ___ _ ___ ___ ___ __ ___ ___ ___ ___ __ ___ ___ _ —_ _T_ T___T___T___T___T___T___T___T___T___T___T __-..__T___T___T___T___T___T___T___T___1 __T___T__'T1TI AB G Er__ __ � � I I I ' I I I I �____� 2 CED I I I I I I I 1 I I 1 1 1 1 1 1 1 1 1 1 I I I I I I I I I 1 1 1 1 ; 1 1 1 1. 1 I I I I I I I I I I 11 . 1 I 1 1 I I I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I I I I I I I I I I 1 1 1 1 1 1 1 1 1 1 1 1 1 I I I I I I 1 I I I I I I I I I I I I I I 1` I � I! ! I - LAC qRC I I I I I I I I I I I I I I I I I I I I F I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I ,. L L � J 1 1 I I I I I I I I I T T , T T -- -- A <<m I\ P1 P, !; I ^ !I �, l ! !\ !\ /! ! !'I 11 !I '9 I /1 �; -� —71 ;--,! ; \, , i�d !V Y'i i`; L___�---J „, L___J.___J __.L__ I I ___J.___J.__J I ___J.___J __.L___J L___J.___�__�J L--_J.__ I ___i__ i 1 11` I I I' f }` I ; ;, / I h I A I _ 11` I I A ! h , li i„`1 i I,r;;, � J "'\i 4`,,,\� " -- - ! �T T- T -T- T T T T� -- - - -- - --- ---T-�;---T---T---;---, - - - - -�T-T T 'T— T T- T T- , ---T- ;--T- T-T- T- I T ��F p3ssso I I I I I I I I I I I I I I I I f l l l l 1 1 1 1 1 1 f 1 1 I I I I I I I I I I I I I I I I I I I I I I I I I I , -------------- I I 1 1 I I I F �E t I ! i � 1 1 I li it i E i li ! it 1 it 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I I 1 1 1 I I I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I I I 1 I 1 I 1 L 1 I I I I 1 1 1 1 1 1 I 1 1 1 1 1 I I I 1 I I :'�EeLL�aEa�o�;oFw�Ew��oao�oaw�n�P �e s ! E%EODr[O.nOCNRnOEA SLrEPAign YOx D[c[i10nE m4v EE HREE FEcePI EY IACnRPELL[ I ! I I I I I I ; I I 1 I I I I I I I __I,J.---.L---J.---J.---i---J,---J.__i�__ __i___ ---J.---.L---J.---.L---i---1__�i---J-___.L___J.___J ___ ___i___i___l___J,___i___i___J.__�J.___.L_r_J.�__.LT__.L___.i___J____J I ___i___.L___J-___i___i___.L___J xw D�wci�er of aP:m....iovi u""�E Pox mxen Paamn. � I mris�wrtxou:rxewx"iExeoniw ^iE.wa"c rv°�Pue. /nl arx[a PR OCOPYx1cx[z03ELacxRPELL x aFPUCnrt[c ROOF 25-0" 25-0' 25-0' 25-0' a`----254` 25-0' P� 25-0' 26'-6d° 228'4r I CONSTRUCTION NEW GUTTERS ANO PLAN LEADERS l:�J JVV, 11 l•J• JLL°O,ll IIJU, PROTECTANDFLASH IIJJ E SHEET NO: EXISTING FLUE PROJECT TRUE O1 ROOF CONSTRUCTION PLAN NORTH NORTH SCALE: 1" = 20'-0" (19 7') A5mO2 SHEET 5 OF 9 DOOR SCHEDULE UPACTOR,RYALUE &43C HINCKLEY AMIRMLY I MAMM00EL DIME11510N9 IWiOWARE NOTED OTY ECCNYS PROPOSED ECCNYS PRO 07 OR TR LVX P09E0 YACHTS GMMUMROUXPDO LOWU 818' a29A'LWF) PERSPEC MOTORED 1 0.0m Q2 SE3WMR=-UF`000R TITMAMLOWU 21'£s1B•-0'M PER SPEC MOTOR® 1 0= 62800 MAIN ROAD ` SOUTHOLD,NY 11971 I I I I I I I I TAX MAP NO.100D-56:6.4 SELECTIVE REPLACEMENT OF EXISTING CORRUGATED METAL SIDING PER OWNER I I # ISSUE/REVISION DATE .00 PERMIT SET 08.03.2026 I I' _I I .01 AMENDMENT 1 08 19 2026 OmT y •• EGYPT .02 AMENDMENT 2 09.01.2026 2,Z78 SF I 468 SF I '- nosVC.SED CELL SPRAY FOAM +00-0' 35-W 35'MINERAL WOOL BATT INSUL I 1358' DRAWN BY:J.LACHAPELLE 4-CLOSED CELIT SPRAY FOAM MAIN B41LOING EAST BAY CHECKED BY:J.LACHAPELLE bA �B bC (D NOTE:THIS IS AN 11"x V"SHEET OSOUTH ELEVATION' DRAWINGS MAY BE PRINTED NOT TO SCALE SCALE: 1" = 20'-0" LaChapelle Architecture PLLC P.O.Box 1251 Mattituck,NY 11952 (631)407-0507 jake@lachapellearchitecture.com I +o I I I I I I I I I I �,�ERED Asp � d ! 4'CLOSED CELL SPRAY FOAM ! I I ! I ! I \ N I I I I ! »1 FNE`1`j�o� I I•. i i I :i I I I I II I'°I I , , I I 't I iNb vRawMO bNN iXaiRvx[x10[a[RVK[pnv R[N4Nlin[PPOveRlrOfl4CwV•lLL[ , � , nMNN[tt5R[rttvFlmPOI[aaMWx[ix[RtMt PROi[ttyORNMcnabPP[PeR[Ob M-rx pNl'R U. oRxmN�iontv^o u uv[LLL i'oP atoomoe u�tw o�rzWvaoi P"n[vs P Ye �nw PPatcte, • oraR Runus�Nmmvrini WP,iexcoxuxoor ucxvauNa<NR[cwn[�itmc.Nt m cRPmaxizote uextPn[e aacmmtnoxt Pue 16820 SF i - 'I ,•. I , � .I I - I ,I I I -� 'I � I I [ ELEVATIONS MAIN BUILDING I i I I I I I I I I (� U O O (� U be m SHEET NO: WEST O TION SCALE:E1 = 20'-0" AT02 SHEET 7 OF 9 HINCKLEY YACHTS 62800 MAIN ROAD SOUTHOLD,NY 11971 I D(ISTING VEN11 ATION FAN TAX MAP NO.1000-56.-6.4 SELECTIVE REPLACEMENT OF EXISTING CORRUGATED METAL # ISSUE/REVISION DATE SIDING PER OWNER 4'CLOSED CELL SPRAY FOAM .00 PERMITSET 08.03.2026 i I I • I .01 AMENDMENT 1 08 19 2026 SF' ----'— Y .02 AMENDMENT2 09012026 I �I EXISTING SIAMESE CONNECTION 354 ,004 DRAWN BY:J.LACHAPELLE I. CEASED CELL SPRAY FOAM+ FAST BAY I MAIN BPILDING 5.5'MINERAL WOOL GATT INSUL - CHECKED BY:J.LACHAPELLE bNOTE:THIS IS AN 11"x 17"SHEET ONORTH ELEVATION DRAWINGS MAYBE PRINTED NOT TO SCALE 1 SCALE: 1" = 20'-0" LaChapelle Architecture PLLC P.O.Box 1251 Mattituck,NY 11952 (631)407-0507 jakeQlachapellearchitecture.com E . SE TSLa aoseD cEsPRAr FOAM 56-MIINRAL WOOL BATI U. 033930 I. � I: I �' � L � I • I. I' I I I ""'--dam I' r- --- -- -------- — -r, I: i ,:o32SP : ---------- --- I ----- -- — --- --I 2003E O ,•I 8;i6 SF I •' I. [�. I InsoaAvnxaenxLxs.Pu"exr oP.ePmce enox[ma�xe lx[Pno.[Prvovwcueveu[ .nenn[erua[nw Peo.POLessovwxnxenlx[vPa[crroPwnm lov[v eou • � a I { ;I, - [x[emeo,noe«Pxcn.nirzw.mx>on oeLmoxaa+avo[xux[exc[n evwcxPvnL[ ,' I I'. I 1 �., � I' � +'I - I '' i , -, I � I. I xn[emP[vLLc rxa oP.wao xox"[e uaeoermx pvurtrta roxmxexrPweele Pi0 o4xxngNiPlXU Pq"/Lci eY Nx[PPta�b PLRaH"[ix3PPWF[I BY II I In[P Pnmrt90-" m uxcxxP[lL[ weM s PLLC [eNPePnc. F—LI 1,,S37 SF ,. „� .969 SF 'I I. 387 SF I I ELEVATIONS 21Td'-- — IS''OISNERAL WOOLBBATT IINSUL ' I'CLOSED CELL SPRAY FOAM• MAIN BUILDING � I 35'MINERAL WOOL BATT INSUL I I I I ,B, b Cl) b b b b b SHEET NO: EAST TION O2 O SCALE: " = 20'-0" A8m SHEET 8 OF 9 HINCKLEY EXISTING FLUID-APPLIED MEMBRANE YACHTS EXISTING CURR.METAL PURLIN SPACING IS 62800 MAIN ROAD ROOFING APPROXIMATE- SOUTHOLD,NY iiWi EXISTING 8"x 3"x 18"Z-GIRT VERIFY IN FIELD STRUCTURAL PURLINS THROUGHOUT EXISTING BUTLER FRAME TAX MAP NO.1000.56,6-4 Sf ISSUE/REVISION DATE SELECTIVE .00 PERMITSET 08.03.2026 REPLACEMENT OF EXISTING .01 AMENDMENTI 08.19.2026 CORRUGATED METAL 1 PROPOSED 4"CLOSED CELL SIDING PER OWNER o2 AMENDMENT2 09.01.2026 SPRAY FOAM INSULATION (R-28)/ AIR BARRIER- EXISTING 8"x 3"x MASK ALL CONDUIT, _ROVID� UOTfFI—"US— �" 16 Z-GIRT HANGERS,ELECTRICAL INTUMESCENT THERMAL_- STRUCTURAL 4"CLOSED CELL SPRAY BOXES,ETC.TO ARRfER COAiT I�G AT PURLINS APPLIED 2-PART CONTROL OVERSPRAY INTERIOR ____ ________ POLYURETHANE DRAWN BY:J.LACHAPELLE EXISTING FIRE SPRINKLER INSULATION(MIN.R-28) CHECKED BY.J.LACHAPELLE � SYSTEM THROUGHOUT EXISTING BUTLER NOTE:THIS IS AN 11"X V"SHEET OFRAMES TYPICAL ROOF DETAIL PROVIDE CONTINUOUS DRAWINGS MAY BE PRINTED NOTTO SCALE SCALE: 1 1/2" = T-O" LO INTUMESCENTTHERMAL LaChapelle Architecture PLLC BARRIER COATING AT t\lei INTERIOR OF Z-GIRTP.O.Box 1251 PURLINSMattituck,NY 11952 (631)407-0507 jake@lachapellearchitecture.com PROTECT EXISTING EXISTING CURR. LATERAL BRACING i CMETAL SIDINGPROPOSED 4"CLOSED CELLSPRAY FOAM INSULATION(R-28)AIR BARRIER-PROVIDECONTINUOUS INTUMESCENTTHERMAL BARRIER COATING AT INTERIOR `r �jA �a3o PROVIDE NEW Op EXTERIOR J INTERIOR INSULATING SYSTEM AT WALLS PER EXISTING 8"x 3"x DETAILS AND SPECIFICATION A 1 "�o,c;aono;;>;°�;ATE roaITo°you; STR�UCTU IRAL CD -v PURLINS - -�---- SEAL OR TAPE VAPOR EXISTING BUTLER i BARRIER PER DETAILS FRAME _ _ SPECIFICATION AT ALL I j PENETRATIONS FOR 1 CONDUIT,ELECTRICAL I SHEET NO: BOXES,ETC. O2 SCALETYPICA1 2;EXTERIOR DETAIL OO STYPICL CALEA1/4ECT10�N @BUILDING ENVELOPE A9mO2 SHEET 9 OF 9 HINCKLEY YACHTS DRAWINGLIST 62800 MAIN ROAD SOUTHOLD,NY 11971 62800 MAIN ROAD A1.01 DRAWING LIST,ABBREVIATIONS, SYMBOLS, &NOTES A2.01 NOTES &ENERGY CODE COMPLIANCE S O U T H O L D, NY A3.00 SITE PLAN A4.00 GROUND FLOOR CONSTRUCTION PLAN A5.00 ROOF CONSTRUCTION PLAN SCTM#-1000-56.-6-4 A6.01 SECTION TAR MAP NO.1000-56:6-4 A7.01 DETAILS NOTE: DO NOT SCALE FROM j D&k INGS # ISSUE/REVISION DATE \C� .00 PERMITSET 08.03.2026 VVV .01 AMENDMENT 1 08.19.2026 e0' SYMBOLS REGULATORY NOTES A B VBE\ 0YI O N S DRAWN BY.J.LACHAPELLE 1. THIS APPLICATION FOR BUILDING PERMIT IS FILED WITH THE A.F.F. ABOVE FINISH FLOOR GWB GYPSUM WALL BOARD CHECKED BY:J.LACHAPELLE LEVEL TOWN OF SOUTHOLD BUILDING DEPARTMENT, IN ALT ALTERNATE NOTE:THIS IS AN='x 17"SHEET O CONFORMANCE WITH THE TOWN CODE CHAPTER 144. APP. APPLIANCE(S) HM HOLLOW METAL DRAWINGS MAY BE PRINTED NOT TO SCALE A WINDOW THIRD FLOOR EL. +31'-s" HT HEIGHT L-ELEVATION ABOVE 0'-0" 2. THE CONTROLLING CODE IS THE 2025 BUILDING CODE OF NEW B.O. BY OTHER HW HOT WATER LaChapelle Architecture PLLC YORK STATE AND THE 2025 ENERGY CONSERVATION CODE OF P.O.Box 1251 O DOOR NEW YORK STATE, IN COMBINATION WITH THE TOWN CODE. C/C CENTER TO CENTER MECH, MECHANICAL CLG CEILING MTL METAL Mattituck,NY 11952 1 ELEVATION NUMBER 3. REFERENCE HEREIN TO 'BC' SHOULD BE CONSTRUED TO MEAN CMU CONCRETE MASONRY UNIT (631)407 0507 fake@lachapellearchitecture.com PARTITION TYPE SHEET NUMBER 1O A6 THE APPLICABLE BUILDING CODES OF NEW YORK STATE. CONC CONCRETE PTD PAINTED CONT. CONTINUOUS 4. THIS COMMERCIAL OCCUPANCY CLASSIFICATION IS MERCANTILE CONT'D CONTINUED RCP REFLECTED CEILING PLAN A3 1 DETAIL NUMBER GROUP M UNDER BC CHAPTER 3. �R�Et7 ,1 `�„ A4 SHEET NUMBER D.H. DOUBLE HUNG O.C. ON CENTER � ��5 �V.ACH- _ lj� 5. THIS STRUCTURE IS CLASSIFIED AS CONSTRUCTION TYPE II-B DIM. DIMENSION <v (UNPROTECTED NON-COMBUSTIBLE) UNDER BC TABLES 601 AND DIA. DIAMETER SIM. SIMILAR 705.5. DISC. DISCONTINUOUS S.S. STAINLESS STEEL VV DWG DRAWING STL. STEEL J6. TO THE BEST OF MY KNOWLEDGE THE WORK PROPOSED HEREIN IS COMPLIANT WITH ALL APPLICABLE LAWS, CODES,AND ELEC. ELECTRIC TYP. TYPICAL �339313 0� STAIR DIRECTION LABELS REGULATIONS, ENG. ENGINEER ��0 N •I't EQ. EQUAL V.I.F. VERIFY IN FIELD 00 UP DN INSPECTIONS EXIST. EXISTING W WITH FL FLOOR WRB WEATHER RESISTIVE BARRIER „ , , O SMOKE+CARBON MONOXIDE DETECTOR SPECIAL INSPECTIONS MUST BE PROVIDED IN CONFORMANCE WITH THE WD. WOOD "^ ro TMR: ^^ ^ TM°°"°` SC REQUIREMENTS OF BCNYS 1704&1705. °""`""�"'""° TM""" "°;, °" °�" ""`" ®[ORl"°YlSO]6lACWJCLLL Af6MRCNP6%1C SMOKE AND CO DETECTORS SHALL COMPLY WITH UL 268,7th ADDITION SCOPE OF WORK DRAWING LIST, FGIJNIDATIGN— ABBREVIATIONS, MATCH LINE THE GENERAL INTENT OF THE WORK IS INFILL OF SKYLIGHTS AND SYMBOLS, & NOTES PERIMETER INSULATION INSULATION OF ROOF AND WALLS IN THIS BOAT STORAGE BUILDING. - - CENTER LINE ROUGH ELECTRIC NO CHANGE OF USE OR OCCUPANCY IS PROPOSED. SHEET NO: BREAK LINE INSULATION AND CAULKING ENERGY CODE COMPLIANCE AlmOl FINAL SHEET 1 OF 7 GENERAL NOTES GENERAL NOTES ENERGY CODE HINCKLEY YACHT'S 1. ALL WORK TO BE PERFORMED BY LICENSED TECHNICIANS TO 11. CONTRACTOR SHALL OBSERVE ALL LOCAL, STATE,AND FEDERAL 1. WORK TO COMPLY w/2025 ENERGY CONSERVATION ACCOMPLISH THE WORK AS OUTLINED IN THIS SET OF REGULATIONS CONCERNING THE REMOVAL,TRANSPORT, CONSTRUCTION CODE OF NEW YORK STATE. 62800 MAIN ROAD DRAWINGS AND AS MAY BE REQUIRED BY THE WORK.ALL DISPOSAL,AND ALL OTHER ASPECTS OF HAZARDOUS MATERIALS. SOUTHOLD,NY 11971 PLUMBING AND ELECTRICAL WORK SHALL BE CERTIFIED BY THIS INCLUDES BUT IS NOT LIMITED TO REGULATIONS THERMAL PERFORMANCE REQUIREMENTS PERSONS LICENSED IN THEIR TRADES,WHO SHALL ARRANGE PROMULGATED BY NY STATE DEPARTMENT OF HEALTH, NY STATE 2. CLOSED CELL SPRAY FOAM INSULATION SYSTEM IS PROPOSED FOR AND OBTAIN INSPECTIONS AND REQUIRED SIGN-OFFS.ALL DEPARTMENT OF LABOR, NY STATE DEPARTMENT OF FOR WALLS AND ROOF. SYSTEM WILL BE INSTALLED FROM WORK SHALL BE DONE CAREFULLY AND NEATLY, IN A ENVIRONMENTAL PROTECTION,AND U.S. ENVIRONMENTAL INTERIOR.CLOSED CELL FOAM WILL ACT AS AIR BARRIER. SYSTEMATIC MANNER.ALL WORK PERFORMED BY THE PROTECTION AGENCY,AND U.S.OCCUPATIONAL SAFETY AND CONTINUOUS INTUMESCENT THERMAL BARRIER TO BE APPLIED CONTRACTOR SHALL CONFORM TO APPLICABLE CODES, HEALTH ADMINISTRATION. CONTRACTOR SHALL ADDITIONALLY AT INTERIOR OF SPRAY FOAM. TAX MAP NO.1000-s6.-6�4 REGULATIONS,AND INDUSTRY STANDARDS. OBSERVE ALL OBLIGATIONS WITH REGARD TO WORKER TRAINING, WORKPLACE SAFETY,AND PROTECTION OF PUBLIC HEALTH AND SEE COMCHECK REPORT UNDER THIS APPLICATION. n ISSUE/REVISION DATE 2. THE PROPOSED SCOPE OF WORK IS A'LEVEL 2'ALTERATION SAFETY. , UNDER SECTION 603.AS SUCH CHAPTERS 7 AND 8 OF THE 2025 AIR LEAKAGE REQUIREMENTS .00 PERMITSET 08.03.2026 EXISTING BUILDING CODE OF NEW YORK STATE APPLY. 12. CONTRACTOR SHALL NEITHER INTERRUPT NOR RELOCATE 3. BUILDING IS LARGER THAN 25,000 SF AND NOT OCCUPANCY I BUILDING SERVICES WITHOUT WRITTEN REQUEST TO THE OWNER OR R. IN CONFORMANCE w/C402.6.2 IT THEREFORE MUST .01 AMENDMENTI 08.19.2026 AND RECEIPT OF WRITTEN CONSENT. COMPLY w/C402.6.2.3 WITHOUT AIR LEAKAGE TESTING. 3. IN ADDITION TO THE REQUIREMENTS OF THE APPLICABLE REQUIREMENTS ARE: BUILDING CODES,ALL WORK MUST CONFORM TO FIRE 13. CONTRACTOR SHALL FILE ALL NECESSARY CERTIFICATES WITH THE a. AOR REVIEW CONSTRUCTION DOCUMENTS FOR DEPARTMENT REGULATIONS, UTILITY COMPANY DEPARTMENT OF BUILDINGS, PAY ALL FEES, OBTAIN ALL PERMITS COMPLIANCE w. c402.6.1 REQUIREMENTS, AND BEST TRADE PRACTICES. AND PROVIDE ANY AND ALL BONDS REQUIRED BY ANY CITY b. INSPECTION OF INSTALLED AIR BARRIER FOR COMPLIANCE AGENCY IN ORDER TO DO THE WORK HEREIN DESCRIBED. THROUGHOUT, PRIOR TO COVER 4. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE c. FINAL INSPECTION REPORT BY APPROVED INSPECTION FIELD.PRIOR TO COMMENCING WORK,AND SHALL REPORT ANY 14. CONTRACTOR SHALL COORDINATE WITH OWNER'S SURVEYOR IN AGENCY IDENTIFYING DEFICIENCIES PROVIDED TO OWNER DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS ADVANCE TO PROVIDE FOUNDATION SURVEY AS SOON AS ANY AND CONTRACTOR FOR CORRECTION DRAWN BY:J.LACHAPELLE TO THE ARCHITECT. NEW FOOTING CONCRETE IS PLACED,AND SUBMIT TO 4. PER C402.6.2.3.1 AIR BARRIER SHALL HAVE AIR PERMEABILITY OF CHECKED BY:J.LACHAPELLE SOUTHOLD BUILDING DEPARTMENT. < 0.004 cfm/fC(0.02 L/s x m2) NOTE:THIS IS ANII"x17"SHEET 5. CONTRACTOR SHALL TAKE THEIR OWN DIMENSIONS AND FIELD 5. PER TABLE C402.6.3 ROLLING DOORS SHALL HAVE AIR LEAKAGE DRAWINGS MAY BE PRINTED NOT TO SCALE VERIFY ALL DATA CONTAINED HEREIN.THE DIMENSIONAL DATA 15. PRIOR TO COMMENCING OPERATIONS ON SITE THE RATE OF 1 cfm/ft2(5.08 L/s x m2) OR 1.3 cfm/ft2(6.60 L/s x m2) IF CONTAINED IN THIS DRAWING SET ARE FOR INFORMATION CONTRACTOR SHALL PROVIDE BOTH OWNER AND ARCHITECT HIGH-SPEED MOTORIZED ROLLING DOOR LaChapelle Architecture PLLC ONLY.THE BUILDING IS NOT SQUARE OR PLUMB SO VARIATION 'ACORD' INSURANCE FORM LISTING THE FOLLOWING PARTIES AS 6. PROVIDE DAMPERS AT ALL OUTDOOR AIR INTAKES IN P.O.Box 1251 EXISTS IN THE DIMENSIONS OF THE EXISTING BUILDING.AS A ADDITIONALLY INSURED: CONFORMANCE w/C402.6.5 Mattituck,NY 11952 RESULT DIMENSIONS OF NEW CONSTRUCTION MAY VARY FROM THE HINCKLEY COMPANY (631)407-0507 jake@lachapellearchitecture.com THOSE SHOWN. CONTRACTOR SHALL NOTIFY ARCHITECT OF LACHAPELLE ARCHITECTURE PLLC DISCREPANCIES AS THEY ARISE. THE CONTRACTOR MAY NOT BEGIN SITE OPERATIONS OF ANY KIND UNTIL THE ABOVE IS PROVIDED. 6. MINOR DETAILS NOT SHOWN OR SPECIFIED, BUT NECESSARY FOR PROPER CONSTRUCTION OF ANY PART OF THE WORK 16. LACHAPELLE ARCHITECTURE PLLC HAS BEEN RETAINED BY THE RED,4RC SHALL BE INCLUDED AS IF THEY WERE INDICATED IN THE OWNER TO PERFORM (2) SITE VISITS DURING CONSTRUCTION �5 �acH `y DRAWINGS. PHASE ONLY, SOLELY TO IDENTIFY SUBSTANTIAL DEVIATIONS FROM THE CONTRACT DOCUMENTS. LACHAPELLE ARCHITECTURE 7. CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES PLLC IS NOT RESPONSIBLE FOR INTERPRETING THE INTENT OF THE WITH REQUIREMENTS OF LOCAL AUTHORITIES AND OWNER. CONSTRUCTION DOCUMENTS DURING CONSTRUCTION PHASE, INCLUDING MAKING MODIFICATIONS AS MAY BE NECESSARY 8. PROPOSED GWB FINISHES MUST COMPLY WITH BC CHAPTER 8. DURING THE CONSTRUCTION PHASE. LACHAPELLE ARCHITECTURE �� 0339313 p TAPED, PRIMED,AND PAINTED GWB IS ALLOWED UNDER BC 803 IS NO LONGER LIABLE FOR WORK WHERE CHANGES HAVE BEEN FOF AND QUALIFIES AS A CLASS-A MATERIAL WITH FLAME SPREAD MADE TO THE WORK SUBSEQUENT TO PREPARATION OF THESE NE INDEX LESS THAN 25 AND SMOKE-DEVELOPED INDEX BELOW DOCUMENTS. 450.THIS EXCEEDS THE REQUIREMENTS OF BC TABLE 803.13 FOR THIS OCCUPANCY. 17. THE CONTRACTOR SHALL ENSURE THE STRUCTURAL STABILITY OF ARCxxEtN�CxaxC6 AL1FPgi10�,°P ttL�Ex°NS MAY GE MACECE[%ttx rt GY IACXAPEt!£ ALLAREAS OF THE WORK THROUGHOUT OPERATIONS.THE °`^°F1em N- D N^ US°a�^­­°F"�­,oua vannEs,im,wur lxE xwnEx coxsxr or uaxuseuE AxcxrtEcruxe we 9. CONTRACTOR TO SCHEDULE AND PROVIDE ACCESS REQUIRED CONTRACTOR SHALL DO SO BY WHATEVER MEANS HE DEEMS ®COP flWM44H4 UCM>LLLHAxH eCNPEi L FOR ALL INSPECTIONS.WORK MUST REMAIN ACCESSIBLE AND ARE NECESSARY, INCLUDING BUT NOT LIMITED TO RETAINING A NOTES EXPOSED UNTIL INSPECTED AND ACCEPTED IN WRITING BY THE LICENSED ENGINEER AT THE CONTRACTOR'S EXPENSE TO & ENERGY CODE INSPECTOR. OVERSEE AND ADVISE ON THE WORK. COMPLIANCE 10, CONTRACTOR MUST COMPLY WITH ALL BUILDING DEPARTMENT RULES OF OPERATION (SUCH AS HOURS OF ACTIVITY)AND SHEET NO: INSURANCE REQUIREMENTS. A2mO:l SHEET 2 OF 7 HINCKLEY YACHTS 62800 MAIN ROAD SOUTHOLD,NY 11971 Q 1 PROVIDE NEW Q I INSULATING SYSTEM AT ROOF PER DETAILS AND SPECIFICATION I I PURLIN SPACING IS APPROXIMATE- Q 1.25 PROTECT EXISTING TAX MAP NO.1000-56:6.4 VERIFY IN FIELD 12 2'�'Y•3' 1, 14�T THROUGHOUT 4'-10' 0.'-10' 4'-10° 4'-10° N-10. 4'-10' 4'-10• 4'-10• 4'•10• 4•_10- 4' 0• 4:10 LATERAL BRACING .10 410' 4'-f0• q•.0.1`-0�3'�•3 I # ISSUE/REVISION DATE EXISTINGSELECT' REPLACEMENT METAL I 51• 5-10 5'-1• g•1• 5,1• `f�l• SIDING PER OWNER �L, { .00 PERMIT SET 08.03.2026 EXISTING B'x 3'X&Z-GIRT q I STRUCTURAL PURLINS FILL EXISTING SKYLIGHTS WI CLOSED CELL REPAIR OR REPLACE STRUCTURAL SPRAY FOAM INSULATION PRIOR APPLICATION v .01 AMENDMENTI 08,19.2026 EXISTING BUTLER FRAMES PURLINS PER ENGINEER'S REPORT OF CEILING INUSLATION SYSTEM-APPLY PEEL N STICK POLYETHYLENE OR PTFE RELEASE SHEET q (GRACE VYCOR OR SIM.)TO ENCOURAGE EASY I L7 REMOVAL IN FUTURE - PROTECT EXISTING I I 4 LATERAL BRACING PROVIDE NEW INSULATING SYSTEM AT Iq WALLS PER DETAILS AND SPECIFICATION I- 700'-0' 135-6" DRAWN BY:1.LACHAPELLE MAIN BALDING I EAST BAY ,1I CHECKED BY:J.LACHAPELLE bb V NOTE:THIS IS AN 11"x 17"SHEET OEAST-WEST SECTION DRAWINGS MAY BE PRINTED NOT TO SCALE SCALE: 1" = 20'-0" LaChapelle Architecture PLLC P.O.Box 1251 Mattituck,NY 11952 (631)407-0507 jake@lachapellearchitecture.com E D I I I I I I I I I I FcAC q C I I I I I I I I I I ! PROTECT EXISTING LATERAL BRACING H 3�1r ivE�� I I I I I I I I � § I I I I I I I Q 5 I I I I I I I I axo6x�x6s..wa .moo er xs,�r6�6 F.x 1� ror�x�I axe'cmiervneoue.nxs oaaxrx6 mnrxm6e osco omw vax�s voamw vxarzrn, wx��cxmrws a+orcerer omen vam .on voncannmaorrxrsrsrrwmer vwiro,vmmour rxe vwrte n eowexr a ucwRuc uexnrcrvrs nw 0 WirpI6M16M lA6WW[LL£tAG"I[fiNne>LLfi b I I I I I I I I V �I 228!Z I SECTIONS MAIN BUILDING I I I I I I I I I I b b b b b b b b b SHEET NO: OSCALE: NORTH-SOUTH E1 Z00SECTION A6mOl SHEET 6 OF 7 HINCKLEY EXISTING FLUID APPLIED MEMBRANE YACHTS EXISTING CURR.METAL PURLIN SPACING IS 62800 MAIN ROAD ROOFING APPROXIMATE- SOUTHOLD,NY 11971 EXISTING 8"x 3"x 16"Z-GIRT I VERIFY IN FIELD STRUCTURAL PURLINS THROUGHOUT EXISTING BUTLER FRAME 4�4' TAX MAP NO.1000-56:&4 # ISSUE/REVISION DATE SELECTIVE I ; Do PERMITSET 08.03.2026 REPLACEMENT OF It EXISTING 11 .Ol AMENDMENTI 08.19.2026 CORRUGATED METAL PROPOSED 8"CLOSED CELL SIDING PER OWNER SPRAY FOAM INSULATION J NIA MASK ALL CONDUIT, --- - (R-56)/ AIR BARRIER- EXISTING 8"x 3"x y '1 ANGERS, ELECTRICAL UOUS 16'Z-GIRT BOXES, ETC.T , INTUMESCENT THERMA STRUCTURAL G AT PURLINS ONTROL OVERSPRAY INTERIOR ------------- DRAWN BY:J.LACHAPELLE EXISTING FIRE SPRINKLER CHECKED BY.J.LACHAPELLE SYSTEM THROUGHOUT EXISTING BUTLER NOTE:THIS IS AN 11"x 17"SHEET O TYPICAL ROOF DETAIL FRAMES DRAWINGS MAY BE PRINTED NOT TO SCALE `y PROVIDE CONTINUOUS SCALE: 11/2" = T-0" "' INTUMESCENTTHERMA LaChapelle Architecture PLLC BARRIER COATING AT INTERIOR OF Z-GIRT P.O.Box 1251 ---------- PURLINS Mattituck,NY 11952 (631)407-0507 jake@lachapellearchitecture.com 0 r PROTECT EXISTING EXISTING CURR. v� LATERAL BRACING REp ", METAL SIDING PROPOSED 8"CLOSED CELL \ ��-ACyq��'�/�� SPRAY FOAM INSULATION(R-56) / AIR BARRIER-PROVIDE �` �' t' a --A{ CONTINUOUS INTUMESCENT - THERMAL BARRIER COATING AT INTERIOR Nj PROVIDE NEW �T 03393o O� EXTERIOR INTERIOR INSULATING SYSTEM OF NEB AT WALLS PER EXISTING 8"x 3"x DETAILS AND 1s'Z-GIRT o SPECIFICATION area noauvrccc>,arzrumus,°e orun reuaerx¢nrer u°wwciu r �oranramics."mw°urns"mrt"+ear�xrar mnumaseu¢a+ewrt�vun�, a— ronao°monromu"xaea°rmnrarurtw,onron mx"umnovrxa rnwea°r STRUCTURAL . „ °r,ucn xu.umarecrvnc vus PURLINS - -- SEAL OR TAPE VAPOR EXISTING BUTLER I BARRIER PER DETAILS FRAME SPECIFICATION AT ALL PENETRATIONS FOR CONDUIT, ELECTRICAL SHEET NO: BOXES, ETC, OTYPICAL EXTERIOR WALL DETAIL OO TYPICAL @BUILDING ENVELOPE A7mO:l SCALE: 11/2 = 1 -0 SHEET 7 OF 7 HINCKLEY YACHTS DRAWINGLIST 62800 MAIN ROAD SOUTHOLD,NY 11971 800 MAI N ROADEP RAWING LIST,ABBREVIATIONS, SYMBOLS, &NOTES OTES &ENERGY CODE COMPLIANCE SOUTHOLD, NY TE PLAN ROUND FLOOR CONSTRUCTION PLAN OOF CONSTRUCTION PLANSCTM#-1000-S6.-6-4 ECTION TAX MAP NO.1o00-66.44 EVATIONSLEVATIONS # ISSUE/REVISION DATE ETAILS AMENDMENT NOTE: DO NOT SCALE FROM DRAWINGS •00 PERMITSET 08.03.2026 E C E n V .01 AMENDMENTI 08.19,2026 u Jib � .02 AMENDMENT2 09.01.2026 " 2 8 OCT 2��U .03 AMENDMENT3 10.07.2026 BuRding Department SYMBOLS REGULATORY NOTES ABBREVIATIONS Town of osolld DRAWN BY:J.LACHAPELLE 1. THIS APPLICATION FOR BUILDING PERMIT IS FILED WITH THE A.F.F. ABOVE FINISH FLOOR GWB GYPSUM WALL BOARD CHECKED BY.J.LACHAPELLE LEVEL TOWN OF SOUTHOLD BUILDING DEPARTMENT, IN ALT ALTERNATE NOTE:THIS IS AN 11"x 17"SHEET THIRD FLOOR CONFORMANCE WITH THE TOWN CODE CHAPTER 144. APP. APPLIANCE(S) HM HOLLOW METAL DRAWINGS MAY BE PRINTED NOT TO SCALE OA WINDOW EL +311-3° HT HEIGHT ELEVATION ABOVE 0'-0" 2. THE CONTROLLING CODE IS THE 2025 BUILDING CODE OF NEW B.O. BY OTHER HW HOT WATER LaChapelle Architecture PLLC O DOOR YORK STATE AND THE 2025 ENERGY CONSERVATION CODE OF P.O.Box 1251 NEW YORK STATE, IN COMBINATION WITH THE TOWN CODE. C/C CENTER TO CENTER MECH. MECHANICAL Mattituck,NY 11952 ELEVATION NUMBER CLG CEILING MTL METAL (631)407-0507 jake@lachapellearchitecture.com 1O PARTITION TYPE A6 SHEET NUMBER 3. REFERENCE HEREIN TO 'BC' SHOULD BE CONSTRUED TO MEAN CMU CONCRETE MASONRY UNIT THE APPLICABLE BUILDING CODES OF NEW YORK STATE. CONC CONCRETE PTD PAINTED CONT. CONTINUOUS 4. THIS COMMERCIAL OCCUPANCY CLASSIFICATION IS MERCANTILE CONT'D CONTINUED RCP REFLECTED CEILING PLAN DETAIL NUMBER GROUP M UNDER BC CHAPTER 3. �FZ�O ARC A3 A4 SHEET NUMBER D.H. DOUBLE HUNG O.C. ON CENTER \�� LACHgA y/� 5. THIS STRUCTURE IS CLASSIFIED AS CONSTRUCTION TYPE II-B DIM. DIMENSION ' (UNPROTECTED NON-COMBUSTIBLE) UNDER BC TABLES 601 AND DIA. DIAMETER SIM. SIMILAR 705.5. DISC. DISCONTINUOUS S.S. STAINLESS STEEL DWG DRAWING STL. STEEL '' _ J6. TO THE BEST OF MY KNOWLEDGE THE WORK PROPOSED HEREIN (P �wb IS COMPLIANT WITH ALL APPLICABLE LAWS,CODES,AND ELEC. ELECTRIC TYP. TYPICAL T � STAIR DIRECTION LABELS REGULATIONS. ENG. ENGINEER Op EQ. EQUAL V.I.F. VERIFY IN FIELD 00 UP DN INSPECTIONS EXIST. EXISTING W/ WITH FL FLOOR WRB WEATHER RESISTIVE BARRIEREE a � SC SMOKE+CARBON MONOXIDE DETECTOR SPECIAL INSPECTIONS MUST BE PROVIDED IN CONFORMANCE WITH THE WD. WOOD MC°MN i°1MI9 Pipi[R BY OMCR PM"VS,°P ipi c°mMl°Y q Tq5 PP°If i 0Y REQUIREMENTS OF BCNYS 1704&1705. 0°CPY1°GMR°f6 UL1YP6fEPIAgfE°NPf PLL° SMOKE AND CO DETECTORS SHALL COMPLY SCOPE O F WORK DRAWING LIST, WITH UL 268,7th ADDITION FOOTING ABBREVIATIONS, MATCH LINE FRAMING,TIE DGWWSTRAPPING AND PLUMBING THE GENERAL INTENT OF THE WORK IS INFILL OF SKYLIGHTS AND SYMBOLS, & NOTES CENTER LINE PERIMETER INSULATION INSULATION OF ROOF AND WALLS IN THIS BOAT STORAGE BUILDING. ROUGH ELECTRIC NO CHANGE OF USE OR OCCUPANCY IS PROPOSED. SHEET NO: BREAK LINE INSULATION AND CAULKING ENERGY CODE COMPLIANCE AL03 FINAL SHEET 1 OF 9 HINCKLEY YACHTS EXISTING 240,000 BTU PROPANE NEW S-BLADE 0.5 HP WO HVLS EXISTING STOREFRONT REPLACE EXISTING SECTIONAL REPAINT EXTERIOR HEATER AT CEILING,DAYTON CEIUNG FAN BY HUMONGOUS MAN-DOOR(UNITAPPROX. OVERHEAD GARAGE DOOR 62800 MAIN ROAD MODEL3E246D FANS S VFD CONTROLLER .,D°wx 6'-1D•h,VIF) (APPROX.21'$wx 1S'h,VIF) � r, Y,� � ,� n 7 n 7 n ,D SOUTHOLD,NY 11971 I� Y 228'$ 14'-3" 25'-V 25-0" 251-W 25'$ 25'-0" 25'$ 25'-0" 28'-Dd3° o - - - - - — - - - - - - - - - - - - — — — — — — — — !— - — — — — — I - - - o O I O I 0 0 O I TAX MAP NO.1000-56.44 If ` L2 �i I \ L3 .! L4•BB - 'll� LS f,l, L6-BB II I ! # ISSUE/REVISION DATE 0 �) .00 PERMIT SET 08.03.2026 Fl - l' ----" I, - I. I 01 AMENDMENTI 08.19.2026 L7 Iy La ',! L9 ' LIO ' L71 !; I .02 AMENDMENT2 09.01.2026 -' .03 AMENDMENT3 10.07.2026 o- B'STEP — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — I`' H3` ! I l ! I 0 L12 III 0 L13 if 0 L14 I' OL15 ;!,' OLIB I OL17 I' 0 L18 I' 01.19 I, OL20 I PARTS ROOM ! DRAWN BY:J LACHAPELLE PAR CHECKED BY:J.LACHAPELLE ! I I I ! ! ! DIMENSIONS ARE ! APPROXIMATE'w IgRINTEDNOT "' DRAWINGS MAYBEP LE F, I � NOTE:THIS IS AN 1 TO SCALE .I,. }'I b O 0 0 0 0 0 O I L21 I' L22 I' In P LL4 L25 'I' LM U L27 - •_ OL2B b °LZ LaChapelle Architecture PLLC r - REPLACE I''_. --- I'`•. .11', %I''.. !'`• %I'', - ,'I'`, - I` I EXISTING P.O.Box 1251 secnoNAL OVERHEAD Mattituck,NY 11952 GARAGE DOOR(APPROX.IB'$ (631)407-0507 jakeQlachapellearchitecture.com 6PRIN1_0_ER /-- "C - %. - ""'\ _ _ %-- _-'\ _ - j-•_ ,'� _ I' ROOM x2T h,VIF) EXIST.HWH - -I' _I' o- — — o- - - i- - — - - - - —o— — — � - - - - � I - - o- - - i- - - - )- - - —o - - - - � I - - o- - - — O L30-BB F, ) I L31-BB I F1 ) I L32 BB I ( F, ( ', L33-BB ! ( F1 ( ,•I L34-BB a LINE OF ADJACENT _ BATTERY BACKUP WHERE , _. _ \ ,• �\ •' ._._ INDICATED BY'BB' n�� I; 6 O O O O O O I O `�' z L35 I L36 L37 I�r L38 InI•.f L40 - L41 '� L42 ; - SHOP ! w �F ! ,e I f `DIMENSIONSARE �T 0.��� APPROXIMATE-VIF O I% SOP NE �o L=U n I I � O JI 0 L 0 I 0 II 0 ff 0 ,III 0 C 0 II 0 L-A-1-1 L7 ',; LI LI LI " LI ,' L7 ''i LI j ' Li �! Il �! ,I .! ':! � .! % DRAWW019AN INS1gUMFMT Gr SER'MFAND gFMNNSrgf PIroPFPTl0I4ACNNELLC AgcgRECNPERIC gECAFDIFS50FY.91ETI1FATIE PPaECTfOg1NNCN RbPREPARCDI4 % c0gH0CMnNCES,ALIIMT0n9,0q DFIsibN5 MAY 0¢HPDE IXCEPFDYIKNAPEllf I<' H, I UP AqD �D�,DgADMArxmeF�FDerD~EgP.q�eDga~�rq�Ee�. HS E` rogoanonronos PgaFnerongn AnanEs Dgroq eoxPumnoema PRWFtt DY o- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — I _ — — — — — mPames.vmmourmcwrmly+mlaFeRDrIxw,RfIEAminenufu REc ®COFYg1DMf0l64GNP41EAPU4RCNRE RIG 25343° 25-0° 26-0" 250 254' 25$ 25$ 26-W a�z6'-04a' Ll GROUND FLOOR 22B'$ CONSTRUCTION ,D PLAN b (4)NEW300,000 BTU PROPAN2E NEW ROUND HIGH BAY LED b CIRCUITING,SWITCHING,B DIMMING AS PRE-SET CCT SELECTION TO LOWEST (4)NEWB-BLADE1.5HP20'OHVLS b b HEATERS AT CEILING,MODINE CEILING FIXTURES,MAKE AND PER OWNER AND ELECTRICIAN AVAILABLE TEMPERATURE=4000 KEL N CEILING FAN BY'HUMONGOUS SHEET NO: MODEL PDP300,41. MODEL AS SELECTED BY OWNER FOR WARMER LIGHT,ALL FIXTURES FANS'&VFD CONTROLLER PROJECT TRUE 1 GROUND FLOOR CONSTRUCTION PLAN w/ RCP INFORMATION NORTH NORTH A4mO3 SCALE: 1" = 20'-0" (19.7") SHEET 4 OF 9 SCOPE NOTES(BASIS FOR BIDDING): H I N C K L EY 1. REPLACE OR REPAIR STEEL EELPURLINS PER ENGINEER'S REPORT 2.PROVIDE ADDITIONAL STEEL SHORING PER ENGINEER'S DETAILS 3.REMOVE AND REPLACE DETERIORATED CORRUGATED METAL WALL AND ROOF PANELS AS MEMBRANE ROOF TO REMAIN YACHTS NECESSARY 4.PROVIDE NEW INSULATING SYSTEM AT ROOF AND WALLS PER DETAILS AND SPECIFICATION 5.PROVIDE NEW LIGHTING PROTECT AND FLASH SOLAR PANELS SEEIrHTS 6.PROVIDE NEW EXHAUST FANS AND RETURN DAMPERS EXISTING FLUE NONFUNCTIONAL' SKYLIGHT SCOPE 62800 MAIN ROAD 7.PROVIDE NEW HEATERS AND CONNECTION TO GAS REMOVE Q ' Q Q Q Q Q SOUTHOLD NY 11971 2 I I �I r - A 22W-4 14'.1" 25'-0" 25'-W 25'-0" 25'-0" 261" T r___T___T___T___ ___T___T___T___T___T___T___T___ ___T___T___T___T__T___T___T___T___.r___T___T___T___T___T___T___T___T___T___T___T___T___ ___T___T___T___T I T I T I I , i I T I i T I II II I 1 1 � 1 I I I I I I I I I I I I I I I I I I I 1 1 I I I I I I I i TAX MAP N0.10 LIQUID APPLIED ROOF TO RI[MAIN I I i i ! I i I i � ! I ! I i I � I i I i OD-56.-6-4 I I - --1 -1-- 1-- I I I I I I I E I +___{___I___ { I___+___t___1___1___1___+___'___+___�___t___1___1___1___+_ t___I___t___1___1___1___1___{__{___{___1___1___ _ T Ir---� ! - n -, # ISSUE/REVISION DATE i !! _T1___1___J L1_i_J ''` i ! SINGLE STOkV I I / II 0 0 PERMIT SET 06.03.2026 -T---T---T---T---T---T---T---T---T---T---T---T---T---T---T---T- r .01 AMENDMENT 08.19.2026 I II li it i i I i i I ! I it I I I I � I SINGLE STORY I F---+--+---+---t---+--!-+---+---+---+---+---+---t---t--t---t---t---t---t---t---t---+---t---t---t---+---t---t---t--F+---+---t---t---t---t---+---t}--t---t---t---t---t---t---i ! .02 AMENDMENT2 09.01,2026 PROTECTAND FLASH i) I I I I I I I EXISTING FLUE REPLACE UTTER AN I I I I I E i i i i i i i i i i i i i I i I i i i i i i i i i i I I I I E I E E I I I I I I I I I `---1--1---1---i---i---1---1---1---1--- ---i---1---1--T�---1---1---'----1--- ---1---1---1---1--•1---�---1---i---1- -- ---1---1--- ---1--- --- -�--- --- --- ---1--- ---J LEADER[ aND .03 AMENDMENT3 10.07.2026 T-Ti- -T T ?-tT T- T-T T T T1;T T- -; -T -T- 'T T T---T T rT T- T -T T T---T T -T------T--jT--- ---T---�---T--T---T---T-r-T---T-- T---T---r---T--- T---T---T---T---T---T---1 I IIII I I IIII E IIIII II II II IIII I I E I I I I I II I I I I I I I I I I EI III I IE IIIIIII III IIIIIII I IIII I IE II ' I I II I II III III IIIIII III IIIIIII III II ' IIII II I I E III III II III IIIIIII F---+---+---+---+---+---+---+---+---+---+---+---+---+---+---+---+---t---+---+---+---+---+---}---+---+---+---+---+---+---+---+---+---+---1 t---t---+---+---+---+---+---+---+---+---+---t---+---t---t---t---t---+---t---t---t---t---t---t---t---+---t---t---t---t---t---t---a I i I! II I I i i I DRAWN BY:J.LACHAPELLE I I I I I E I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 11 I I I l 1 1 I r-- } I l i +- i!t -+-+ al i ---t-+ t! t- t -+ -- -- - --+- - +---+--+ -+---+---+---+---+---+--+---+---+---+---+---+ i I! CHECKED BY:J.LACHAPELLE I I I I I /1 I ----�-�I---1I ---�---1---_I --1I---�E---1I--�1I 1I �I ,� 1 r---1 t---1---1--_-1---n--�---�------�--' I �� NOTE:THIS IS AN 1 x 17"SHEET ; ---1---1 1- 111- 1 --1---1---1---1---1---1---1---1---1---J---1---1---1---1-- _ --- --- -- -------�---�--- --1---1---�---1---1---1---1--- Sr DRAWINGS MAYBE PRINTED NOT TO SCALE " rL I 1 /r I I- -- `f I I T--�, ! r T ,I ' 7! r T -T �, i I %I I - t,l; -- /,;I I%,,i i 1'�! /;I ` i ;t,;l LaCha elle Architecture PLLC I I I I I i ' p �_J� L__ L_ L__j i L___J L__J I i --_J L__,J L___J --�L__J , L I I-__1___J I `-__1___J I/ L___1___J '/ ?===T=-T- T1 ;===r= T T - __=;---. -� T- T- T--T T -� P I T T T-fir=TT T--T -T T-1.-T===T==T T -T-T-—T- ===T===T T- T -T---T--, P.O.Box 1251 Mattituck,NY 11952 I I I I I I I I I I I I I I I " I E I I I I I I I I I I I I ; I I E I I I I I I I I I I I I I I I I E I I I I I I I l i___i___i_ �--1___J--------- -------------------- 1___1___1___1 �--1___1___1___1___1___1___1_ 07 0507 jake@lachapellearchitecture.com I T f 1 fi -r - T I r _ T I (631)4 I I I REPLACE EXISTING VENTILATION FAN _ I RIDGELINE 3d-0' __T I_ ........... __I___T I I __ __I ___ ___ __ ___ ___ ___ ___ ___ ___ ___ ___ ___I___ ___ ___ ___ ___ ___ ___ B __T___T_-_T___T___T___T___T___T___T___T............... __T_ _ _ _ ___ ___ ___ ___ _ __ ___ ___ ___ ___ ___ ___ _ ___ ___ ABFTIFr.'OLFIFT- T- -� ---T -T T I ® I T Zl i I I T i �____-i li ;I T i a I 2 m I I I I I I I I I I I I I I I I I I I I I I I I I I I I I m I I I I I I I I I E I I I E + I I I I I I I I I I I I I I I I I I I I I I I I I --- --- -- --- --- --- --� --- --- --- --- ---+---+--- a-- --- --- --- ---t---+--- --- --- --- --- ---t---'---t---t--�t---'-- --- --- --- --- --- - --- --- ---t---'-- --a I---I---I---I---I---I---I---I-�-I---'---I---I---I---I---I--- --- --- --- --- --......... F + + + + + + + + + + + + + + + + t � + + + + +-T ,I -- t +-+ + + + + { + + { { + { + + + + -� t } t ta AB I I I I I I I T I i t I I i I tED R� -- ---�----------------- -�- -�- -� 1 -1- 1-1 1-1--1 -1 1- J ` -1 1- 1--1- 1 i--1 1 1-- --� 1 I I I I I I I I I I I I I I 5 c i I I I I I I I I I I I E I I I I I E I I I I I I I I I I I -�_--�---1-- -__ ___ -- I I I , -- --- --- ---1---1---1---1- - ALA H I I I I I I I I I I I I I I I I I I I I I I I I I I r---T---, r---T---, -- —' r---r- � -- -- AA� I E I �___ - --;T1---1--=;-- --- ---,�_-T===1-- --�;---,---,-- --- --- � --- --- --�===T===;- 1�-1---;--;---J � I /ill !il i` 'I ! i !Ii I yl I I I I I I I I I I I I „Itl, I I I , I I ' I II `„ L 1--' ' A -1 1- J -1--J 1 J --1- 1 - `---1---� `---1---J ! ;� I I ---1-- E�I '3 T i,',1 i � I11 !,l � I ,+ I L I I I I L -J I v I;- I��,� !L �I,,�; `' I J I/ `I `I __ L__ -__J L___J ___J ; L___ L___ —T T- T T-T -T LT -T T--T -T T T� Ti ?- T T--T---T- - - - - --T-1T T T -T - T--T T -T- T-T---T 1T T -- - T L-T --- T 1N -- ---- I 03393fl - - o� IIIII IltElll IIIIIII IIIIII IIIIII IIIIII I I IIIIIII EIII I1E111 IIIIII IIIIII IIIIII IIIIII I I I IIII IIIIII II IIIIIIIIIIIIII IIIIIIIIIEIIEIIP I IIIIII I IIIIIIIItElEllrllllllllllllIl Ir---+---+---+---+---+---+--r+---+---+---+---+---+---+---+1--+---+---+---+---+---+---+---t---+---+---+---+---+---+---+-t+---+---+---+---i F---+---+I---t---+---+---+---+---+---+--1+---+---+---+---+--+---+---t-r-+---� L---t----�---t---+---t---t---t--t---i I li I !I I i li it li it i I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I F---{---{___.___+___{___�___t___�___t___{___{___{___{___t___t___t__t___t___{___{___{___{___{___{___{___�__t___t___t___t___t___{___+___� F___t___{___{---t___t___{___{---{___{__t___t___{___{___t_—t___t___{___J L___t3___t___t___{___.F___{___t___� 1 . TgSDMMcI5AXIX51P4YXXfO E S MC—E¢IM¢15iXfPPOPw ai A NAttuE I I E C�E0.XOCX4"9u fan a�E ¢Pm4Y¢FMPo �R¢ XE� __j___ --- 1___1___1___J L___J.___J!___1___1___i___1___1___1___1__.�1___1_r_1l__1T__1_-1___1___� ___1___1___1___1___1___1___� APCWIECNPEMLGTRf NWWINGtMV NOTOFUSEP pYoiHw PMiIES tDa OINw RiGi[cIE. uPoomoxmnes PPwFneromwvumEs.mroPwunEnonoF>r�PPatEn In mwvwwa.LwmourfxEwmrtn+wysFXra ucX.fP,uFucwurvPE w�c o- — - - - - - - - -! J -- - - - - - - - - - - - - - - - - - - - - - - — -� - - - - - - - - � - - - - - - - - -o Nr,CEId04+➢F,fEPMJp,FCNPF Ptic 25-. a� 264" 25-0" 2T-T ate-2V4r al--- 254' 234" 26-V 26'-043' ROOF 2261V CONSTRUCTION LEADDERSERS NEW GUTTER PLAN IJJ• IJJ• IJ:IJ 11J, llJ• `JJ\ PROTECTANDFLASH IIIJJJ SHEET NO: EXISTING FLUE PROJECT TRUE OROOF CONSTRUCTION PLAN NORTH NORTH A5mO3 SCALE: 1" = 20'-0" (19.7-) SHEET 5 OF 9 DOOR SCHEDULE U-FACTDR1R.VALUE SNGO H I NCKLEY ID ASSEMBLY NOTE MAKENODEL DIMENS-S FIARONARE S Div EOCNYS PROPOSED ECCNYS PROPOSED YACHTS Q1 SEGMENTED ROLL-UP DOOR TR AX ANMLOWU 11r4'X2V-V'V F)_ PERSPEC MOTORMEO 1 O.OSB QQ SEGMENTED ROILUP DOOR TRPN MA%LOd/U 21'8'w 1S'-0°dVST PER SPEC MOTOR. 1 0.037 62800 MAIN ROAD SOUTHOLD,NY 11971. I I I I PREP AN SHE PAINT EXTERIOR I I TAX MAP NO.100056.-6.4 AL SIDNG SELECTIVE REPLACEMENT OF I I EXISTING CORRUGATED METAL SIDING PER OWNER I d I I li ISSUE/REVISION DATE 1''ul I'.' P•. ICI it 11 ,I i!:I�la : -- - I 'N IIV„!„.IN ±I.i'. !„ '.� Il' % :! %,��„ !II .01 AMENDMENTI 06.19.2026 PORT 9 III.. 999 11 �I V� EGYPTI .02 AMENDMENT2 09.01.2026 1 1 SI I - I. { 9 9 I li�l d' ul, .03 AMENDMENT3 10.07.2026 IS �, 1:1' I 1 �� � .,.... II 1 I ) 31'd 14 ,fl iI 12,279,,SFII,I d :I �I IIvINI I I'I illl'.II� RI V ! 4583ERlil. il•Il a ,d',':! 11II'CLOSED CELL SPRAY FOAM. IIS I. 100'6"� 356" I 3.5"MINERAL NpOL BATT IN UL 1356" DRAWN BY:J.LACHAPELLE 4"CLOSED CEL�SPRAY FOAM MAIN BUILDING I EAST BAY CHECKED BY:J.LACHAPELLE bb b bD NOTE:THIS IS AN 11"x 17"SHEET SOUTH ELEVATION DRAWINGS MAY BE PRINTED NOT TOSCALE SCALE: 1" = 20'-0" LaChapelle Architecture PLLC P.O.Box 1251 Mattituck,NY 11952 (631)407-0507 jake@1achapellearchitecture.com I I I I I I I I I 10 aD A�c'Si ape PREP D REPAINT EXTERIOR SHEET METAL SIDING Try- I 4" LOS D CELL SPRAY F I I I I I I N I I I I I I I qT os39 6 d d r d I di a N I 1 i fl l i I 9: I I I 1 I 11, N V d 9 JIB � F L N i 4� i 9 1 I a' yy J• I I:9 1 I I I 1 ,d J I N'I •'I li �I Y 1 I ! I � I i I I 9 r , ] I I 1 ,! I I 11 I S fl � i t! NI I �+'! I I •:I[ '-t J ExsoPAmxo Maw wsmusur,ToesomanxoacmtuxslXE PnoPcn r J: na vsHnosu¢ : 9,. dd I I �1.l r .xw,ErnaEPuoa wrmcmEeTXEP[rolEar Rvm 11 I d9. 7' EGGRWES9 o KxnuPXVAwee,s I'd I � 9 � I 91 I' '1d,• , : � .i l•:, I II 1 Id � I 1• I I�,.I ',7 I.' � ..I I. 'l:. II � y :'I r I u,rza Xocxnxe®u1e[wEwn,oRoeunorM mnr ee msDE excePr nr: 1 1 I �' 11 ucx,PEut I iI I I. I d I I l 9 '',1 , ' 1'I'� I wnan ox rolwc Ever ameRParmrs oRrox mmPinanor I .' 1B , i I':I JJ.�1 an ww TxMww,Ec7 Er I''ir,, � � q I I.:° Y rn es SwlmoerTxewmSED+CO[MEt1Ea5rWWVfuEAPC nern nun Itl Id ) I R ,I d I I W: N I 'd'' � � �' d. 7r 5' ®EAv(AGM303e APCNRECN EP4C ,i I I 1 :I !^ ,�: ICI• ,"' I. i � I ll 1 3 pf.I, +I .,I gg ! ' :. I,. f • .. ,.f'1''. .3. :: + :,F I �.,:, .. .idll�.�R� '.a . i. 9.11..::°:.�',''.�a:%.•:. , ,,.,d G,IIe : I�'1,::5. dI i ha � `Ili•.. ,,.,,,,i i.i.l„3.�.,1 ��),,,• IISI,�,II,',,;li�.. ,.d. � i �all:il:l:ll !J,IS:Idi. dl:::.I,�V_�..III.,-.) I ,I.d..! d.:�:.�.11 i..�di�ld�ll,lll d d,....1. I..,�:R�..I%a:l[, d ,,.. ., ....� %d�l,�,..d .,�r :�.: ... I I�'..I,.,:.. � t -�d � .., II. ELEVATIONS 228'6" MAIN BUILDING I I I b b b b b b b b D SHEET NO: O2 WEST ELEVATION AT03 SCALE: 1" = 20'-0" SHEET 7 OF 9 HINCKLEY YACHTS 62800 MAIN ROAD SOUTHOLD,NY 11971 I I I REPLACE STING VENTILATION FAN I I TAX MAP NO.100056.6.4 PREP AND REPAI T EXTERIOR I SELECTIVE REPLACEMENT OF I I SHEET ETAL SIDING EXISTING CORRUGATED METAL # ISSUE/REVISION DATE SIDING PER OWNER 4'CLOSED CELL SPRAY FOAM y { I I rd I I I I�I' � I rlfl i'�� I I �� IIJ Iddd�dl I: I � I �1�i] � 1,1:'l 1 �ryaJ' I' I I, ; .00 PERMITSET D6.03.2026 fll I •Trull 'I; I:Ir I 'I II 'r y illl �" 111 I J j ui:•I 1�i:3�BF I�r. 9JI d q r J •�1 - 1 �' . .01 AMENDMENT I. 08.19.2026 i 844 SF AMENDMENT2 1.2 'i'3se"sF _ 'I ryi I i 3�9 ..... .... .03 AMENDMENT3 10.07.2026 IM1�r / �I I71�II111,1 111� I � I7 111 :d91aINI911N11 Il lII1II IIII�a i14 11 I� ''�!181r1 V19J,:I.InR9 J vJ: � 4�tl821;INV I IO Nii I��I I I EXISTING SIAMESE CONNECTION 35'-t 135'-6" DRAWN BY:J.LACHAPELLE ,-CLOSED CELL SPRAY FOAM+ EAST BAY MAIN B�IILDING CHECKED BY:J.LACHAPELLE 5.5'MINERAL WOOL BATT INSUL bb b Ab NOTE:THIS IS AN 11"x 17"SHEET NORTH ELEVATION DRAWINGS MAY BE PRINTED NOT TO SCALE O SCALE: 1" = 20'-0" LaChapelle Architecture PLLC P.O.Box 1251 Mattituck,NY 11952 (631)407-0507 jake@lachapellearchitecture.com ED �CC PREP AND REP NT EXTERIOR I I I I I I * � -� � 'ES ' SHEET ETAL SIDING I I I I I I I Cff 4"CLOSED CELLSPRAY FOAM 1'FFLOSEO CELL SPRAY FOAM+ 03393� O� MINERAL WOOL BATT INSUL y G F� t�I '9 1.d I I I jr I I I M 77 {6 i � I lal .i I �� i •I 9�r' 'I 1 I 4 I d I fl I 1 !d I� I 7 i�• � 9y I l I. ,I Y Jr r1 1.i fl �s I {a J {{ 1, 'I a yll I I I, a :7 r ! 4y :I u r ;r Ir .7:':; n msoanmrccwax wsmuxnnorsomauroiemursr�PRormnoi ucwvEuc It:'Y {1 it r I J 1I - PAYPT �' CMt1ELNPEP.tcpWPAplf%Op MNEMERiI1EPPWECiiORNTICN R6PPFPPPeU6 III 1, r J I �I ? � { � � <{, o�aeurEanocrwwrs.uaPnnau.aROEirno eEru"E EecEnar ieewiaeur 9g: I r,Y�., I j.. � 4r a': I'' � d r Jrr d :i a I , - tl.. I .I a+cwr[cmvEPuc�snxnwixs w.rnmeeusE eroraunumEsioao>»ia rtwens, I�'I. I ,I �; pp �°'.. I I �i 1 3 yapr1 i':1 .'� :I d i,:I , �. a I 1 1 r 'i� I{ wnaomnon roiwsrxmEcreroranPnana o"imcoxlnmo ,wsPnwEcrer I I -' it { � I'. d' !". 'I. I �' I .I•: 'I". '3 1, ammPaan imo"rmewmrtEnmxsErrtov ucnnlaucaacxmcrvra Pue!,r. { J d I �I r 'I i � { { l i it q' I{i�:I v, ' I t ®raPrawnrawE uewaEuienewrzervaE nic { :IlIa11l., I,J,I{ �Yr ?! 19.1 p .I r I, I. J II 111 �:i -38TSF 83TISF r ,i'. ,l tl ;rl� i� 13i':$ 1911 1'I!r :, 'dflYidl:ltld+tl l:l ii 9J:r.r �l�' NXdI'Ja '"I �:I'I {I Ira'u1dP 11.1. ,�Ir,rl�tl111u.r. ,11. IId�d�,rr Id�11�_ 1�,�.: :111 di la Ild Id111+19���1 .I.d � 9:Id11 ,�� ,.� I- .s O 217,-0, I 1 I VC BED CELL SPRAYFOAM+ ELEVATIONS 6.5' INERAL WOOL BATT INSUL ,'CLOSED CELL SPFq�AAY FOAM+ MAIN BUILDING I I 3.5"MINERAL WOOL<IATT INSUL. I I I b b b b b b b b b SHEET NO: OEAST ELEVATION O A8mO3 SCALE. 1 20 SHEET 8 OF 9 HINCKLEY EXISTING FLUID-APPLIED YACHTS MEMBRANE EXISTING CURR. METAL PURLIN SPACING IS 62800 MAIN ROAD ROOFING APPROXIMATE- SOUTHOLD,NY 11971 EXISTING 8"x 3"x 16'Z-GIRT VERIFY IN FIELD STRUCTURAL PURLINS THROUGHOUT EXISTING BUTLER FRAME - TAX MAP N0.1000-56.-Cr4 0 ISSUE/REVISION DATE SELECTIVE — - .00 PERMIT SET 08.03.2026 REPLACEMENT OF EXISTING i1 'i .01 AMENDMENTI 08.19.2026 CORRUGATED METAL 1 PROPOSED 4"CLOSED CELL SIDING PER OWNER ; ; oz AMENDMENT2 09.01 zozs NIA SPRAY FOAM INSULATION .03 AMENDMENT3 10.07.2026 (R-28) AT CEILING/ AIR EXISTING 8"x 3"x 1 MASK ALL CONDUIT, -- - - IDE 16'Z-GIRT HANGERS, ELECTRICAL CONTINUOUS INTUMES STRUCTURAL 4"CLOSED CELL SPRAY BOXES, ETC.TO ER COATING PURLINS APPLIED 2-PART CONTROL OVERSPRAY AT INTERIOR _ POLYURETHANE INSULATION AT ROOF DRAWN BY:J.LACHAPELLE EXISTING FIRE SPRINKLER (MIN.R-28) CHECKED BY:J.LACHAPELLE SYSTEM THROUGHOUT EXISTING BUTLER NOTE:THIS IS AN 11"x 17"SHEET TYPICAL ROOF DETAIL FRAMES 3„CLOSED CELL SPRAY DRAWINGS MAY BE PRINTED NOT TO SCALE O APPLIED 2-PART SCALE: 11/2" = 1�-��� � POLYURETHANE INSULATION AT WALLS, LaChapelle Architecture PLLC TYP.(MIN. R-21) P.O.Box 1251 Mattituck,NY 11952 PROVIDE CONTINUOUS (631)407-0507 jake@lachapellearchitecture.com INTUMESCENT THERMAL BARRIER COATING AT r Q INTERIOR OF Z-GIRT EXISTING CURR. PURLINS FED ARC PROTECT EXISTING �� lS METAL SIDING LATERAL BRACING 0�5 �ACNgp�` PROPOSED 3"CLOSED CELL SPRAY FOAM INSULATION(R-21) U111 AT WALLS/ AIR BARRIER- PROVIDE CONTINUOUS - -; C> INTUMESCENT THERMAL r BARRIER COATING AT INTERIOR 0339'�P y0 PROVIDE NEW TF O F NE°� INSULATING SYSTEM EXTERIOR INTERIOR AT WALLS PER EXISTING 8"x 3"x DETAILS AND Q "Z-GIRT SPECIFICATION W50UKN05AVPSWREMO ERAEPN NRlNNSTEPPOPp 0 F[WPllF �WRLNPE0.L0 F[OerOLEOMM¢LXE0.m�E�P�Ecf POP WNCMRLS^t@MFO^ 16 i NFHI ER PLPG��OP N9G WL o00KNPM SogOM gPROE R, STRUCTURAL _� X.OPRONIo1144PXO1ECf9Yv0¢PP�P,"" „,,,„mP�ERR,fOOMLN PARRES.WiMOVETR WATEH CON OPLROWwfY{MCMfFLNPEPLL4 �, ®<OPfPK.Xi:OR91ACXMELLEAPCM1FCNiiE PLLO PURLINS - -- i i SEAL OR TAPE VAPOR EXISTING BUTLER BARRIER PER DETAILS FRAME _ ____ SPECIFICATION AT ALL PENETRATIONS FOR 1 CONDUIT, ELECTRICAL SHEET N0: BOXES,ETC. O TYPICAL EXTERIOR WALL DETAIL O STYPICL CALEAI/4ECT10�N @BUILDING ENVELOPE A9mO3 SHEET 9 OF 9