Loading...
HomeMy WebLinkAbout51715-Z �o4X%of SO�Tyo`o Town of Southold * P.O. Box 1179 o�X' 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 47142 Date: 06/16/2026 THIS CERTIFIES that the building Swimming Pool with Fence-In Ground Location of Property: 800 Corey Creek Ln Southold, NY 11971 SecBlock/Lot: 78.4-12 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 01/28/2025 Pursuant to which Building Permit No. 51715 and dated: 03/06/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Accessory in-ground swimming pool fenced to code as applied for. The certificate is issued to: 800 Corey Creek Ln LLC Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: AE260510-73436 5/10/2026 PLUMBERS CERTIFICATION: 1 A ho ed Si ature ��oFso�Tyo TOWN OF SOUTHOLD BUILDING DEPARTMENT • 4 TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51715 Date: 03/06/2025 Permission is hereby granted to: Alfano Family Trust PO BOX 266 Laurel, NY 11948 To: construct accessory in-ground swimming pool as applied for. Pool equipment must be located a minimum of 10 feet from lot lines. Premises Located at: 800 Corey Creek Ln, Southold, NY 11971 SCTM#78.4-12 Pursuant to application dated 01/28/2025 and approved by the Building Inspector. To expire on 03/06/2027. Contractors: Required Inspections: Fees: SWIMMING POOLS-IN-GROUND WITH FENCE ENCLOSURE $300.00 CO Swimming Pool $100.00 Total 400.00 Building Inspector f ? G� ALLIANCE ELECTRICAL INSPECTIONS LIMITED 707 HYMAN AVENUE, WEST ISLIP, NY 11795 It 1 SECTION: 78 BLOCK: 4 LOT: 12 CERTIFICATE NUM: AE260510-73436 ; BUILDING PERMIT NUMBER: 51714,51715,51716 CERTIFICATE DATE: 05/10/2026 FINAL RESIDENTIAL ELECTRICAL CERTIFICATE THIS CERTIFIES THAT ONLY THE ELECTRICAL EQUIPMENT AS DESCRIBED AND INTRODUCED BY THE APPLICANT NAMED ON THE ABOVE CERTIFICATE NUMBER AT THE PREMISES OF: i ( a s PAUL DAVEY,800 COREY CREEK LN,SOUTHHOLD,NY 11971 n 3 INSPECTION WAS CONDUCTED ON 05/10/2026 AND WAS FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRICAL CODE AND/OR NEW YORK STATE APPLICABLE CODE ATTHE TIME OF CONSTRUCTION IN THE FOLLOWING LOCATIONS: A d Garage,Attic,Basement,First Floor In Ground,b,O)Outside,Second Floor,Cabana/BBQ 1 Service-Residential 200A Overhead 3 Smoke/Carbon Combo p 1 Septic Pump 4 Exhaust Fan 1 Hot water heater 1 Door Bell Transformer 1 Oil Fired Heating System 4 LED UC Light(s) 2 A/C Condenser 1 LED Driver 2 Air Handler 90 Fixture 2 A/C Disconnect 1 Fixture-Pendant(s) 1 Washer 9 Fixtures Outside ¢ i 1 Dryer 1 Flood Light 1 Wine Fridge 15 Porcelain fixture 1 Dishwasher 5 Vanity Mirror Light 1 Range Gas 1 LED Fixture s 1 Microwave 1 Fan box 1 Exhaust Hood 4 Fixture Incandescent 's 1 Fireplace 12 AFCI Breaker 15A 5 GFCI Receptacle 1 AFCI/GFCI Dual Rated Breaker s 3 Receptacle WP 3 AFCI Breaker 20A 2 Receptacle Island 1 Pool-Residential In Ground } 2 Refrigerator 1 Bonding Pool#8 72 Receptacle 1 Pool Heater s 56 Switch 1 Pool Filter 10 Switch(es)3-way 1 Pool Panel ; 1 Switch(es)4-way 1 Pool Pump/Motor 1 Caseta Switch/Pico Switch 3 Pool Light 1 Heat Detector 1 Low Voltage Transformer 5 Smoke Detector 2 Chandelier 1 Sub Panel z APPLICANT: NEUBAUER ELECTRIC I LICENSE NUMBER:KAI BAUER SUFFOLK 3867 ME a 407 B LEXINGTON AVENUE ,WEST BABYLON,NY 11704 i I'r' �I- CATALIN DUMITRU PRESIDENT 631-539-6055 S E4k. ALAN GAGNON i VICE PRESIDENT 516-248-0820 r THIS CE TIFICATE MAY NOT BE ALTERED IN ANYWAY AND IS VALID BY THE PRESENCE OF A RAISED SEAL AT THE LOCATION INDICATED THIS CERTIFICATE IS VALID FOR ONE YEAR FROM THE DATE OF ISSUANCE OF SO�TyOIo # # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL � e� [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR FIELD INSPECTION REPORT --DATE COMMENTS V FOUNDATION (1ST) F7--------- -------------------------------------- - FOUNDATION (2ND) ......------- ROUGH FRAMING& PLUMBING ----------- ---------- INSULATION PER N. Y. STATE ENERGY CODE Or% oe!N FINAL ADDITIONAL COMMENTS \rvc—t— ()w5(s- 0 C�c m rl TOWN OF SOUTHOLD—BUILDING DEPARTMENT V AV Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax (631) 7 -9502 htips://www.southoldto)MU.gov 6 Date Received APPLICATION FOR BUILDING PERMIT .. .., ,1i *1 U For office Use only PERMIT NO. Building Inspector: �5 -ea- 0'i IC9, R R- b, �101% P e 'vu,MUA UZWY07 Date A'� Name: Project Address SCTM#1000- v9.1V d -SG d f A"- :7 Phone#: T-6 Email: Mailing Address: C cee--,' L//,,j J 7AI'd i-Z tj 1-7 - W7 7—� Phone#: Email: -g, AV11N9 Name: Mailing Address: DU Phone 9 3- Email 'WRA Name: Mailing Address: v 1. Phone#: Email 4V C Q i'M Oh'PROF "s ,Wew Structure ElAddition E]Alteration E Repair ODemolition Estimated Cost of Project: E10ther 7- P . . Will the lot be re-graded? E]Yes,;RNO Will excess fill be removed from premises? [:]Yes 1�140 O 1x O n -51 .BMW- PIP PE fi11'�1 .x $, Existing use of property: j ( Intended use of property: S- �} - ... Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to i this property? ❑Yeso IF YES, PROVIDE A COPY eC1 B Aiiter @at In : tFie nwner�contraeEpr��es�ge profe sio �lis respn6s0 —iji a,A drainage46 ded bey" Lb 56Dft#ae oi�vndie+APP�1C1►10 i4IsHEREB�f,NWDEtoilfe Wai{r�gAepartrpentfortl�2,iss ance+affa utltlingBerm p�rsua%x otheB+si1�MgZone t f t �..�rdrnane� +y�.,eT��oFSgiafoal'drSuf�o1�L'ouatY,�eNrY6'rkanr� grapj�hs�i.�e`flaws;�]riilaa�►��.oK�egt�fat�ons,�ioftfiecb»strdcAn�fbu�ldngs,� ,, , rF-'��M rl" ,,+�r�a: 1?"t.� ...:,ls.t?ra a"r,,v,.:�,$ +i J'f•,.: e5»,'..✓i,! s'.,:'.:v T.y�-.,•,dv..,rt. v...r,q;:• ik' :...��, .r rs•.,:.�._ � e f t°Mc; w y; 4�-5 N+s.y�="4' ;��d'iti`� akeratt�h fr ftlr rer►��a`�1`���nnhRQr`�`af rierei�des�r�b'er1,7t�e,�PPl�canY e' `tA rar'nP�Y, �ag a4pli2able Inws ordm�nees budding,c#�de,� k ��j��! •.:4.x,"z•t'.vtFjy.A e,<;!:y4"?"5 tls;i,^,<,.i`.,r.;t r.. ..hu�`..a?.•f4`J• F,sh..;:.«� sNJ'';,,f.Y.fix aa:�' .JtAw '� -E>h;,e �br' l a s4 �'h 1 '� f XE ���"'juSmgx�rode a�id�gu��ttro�S���a�nn�ac�tfiori�ed rltspectors Orrr�pri7se�?�rl�Y�� 1�l�irig�s�,�#cir nyecessp�l��sp6rMs P,�ls��aY�em�e�M mad�,�eienft iFe, ': >�'ra{1ni5�w6T��s�.,C�2s59Am15t�Emea�or�`4r'suantfo-Set+on'*�7.O,�IStf�fr�s;i eLV*���+�'¢k$-���12��11)Y.�` "`� :s � ,s�' $ �"' r=•,kd qr x tar a Ai;t;,,n,.., Application Submitted By( name): Ve authorized Agent ❑Owner • Signature of Applicant: Date: ®- STATE OF NEW YORK) SS: gg COUNTY OF SVV1E:F6 1 Lq V e being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the (Contractor,Agent, Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;,that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this O day of 7Fo vu 20 `'' "` Not ry n YODY A.STQ.P01 lit No'ia,,Y Put�l� Xk c,State of Mrv) 070979 PROPERTY OWNER AUTHORIZATION no&j St&j flt�ji�1 in CUM (Where the applicant is not the owner) �*nsanExR lan I� residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 Buildthd Departmen#Apphca�ion AUTHORIZATII (Where the'Appiicant is not the Uvvner),; (Prmtp=operty owner>oname ), (1Vlaahng Address ..tiV 1l ! �C` Arlo hrel�y authorize (Agent) .. . .V� to apply on my bbhaf to the Southold Building Department Lj id (Owner's Signature) . (Date) (Fnttt Owner's Name) S.C.T.M.# DISTRICT 1000 SECTION 78 BLOCK 4 LOT 12 #R-24-1894 SUFFOL KCOUNTY DEPARTMENT OF HEALTH SERVICES PERMMIT FOR APPROVAL OF CONSTRUCTION FOR A SINGLE FAMILY RESIDENCE AND Pool House DWELLING FFL 17.5 4" SDR 35 DATE 1/23/25 H.S.yR] EF. NO. R-24-1894 ITCH 1/8"/FT APPROVED °�cvZt4l /�-a� GRADE 15.0 GRADE (14.8) GRADE 5% MAX EL(14.8) TOTAL MAXIMUM BEDROOMS 4/0 C/O TO GRADE INV13.52 DIST INV13.32 EXPIRES THREE YEARS FROM DATE OF APPROVAL INV14.03 INV13.72 INV13.a: BOX EL13.53 INV13.2 2 EACH 4"SDR 35 4"SDR 35 8(0x6'DEEP Revised Plan Approved 2/16/25 PITCH 1/4"/FT PITCH 1/8"/FT LEACHING 1/23128 POOL o o Expires 000000 EL9.32 000 0 0 o E. NEE RCS CE-IFICAT,ON R.O.R.P. FUJITT NNS EL7.53 SU.N,T P.E-OR R.A.Cr RTR,CAY.m CE.•5 rm INSTILLATION Amp CONSTRUCTION O. I/A O WTS HIGHEST EXPECT. GROUND WATER EL 2.0 FOR F,NALA-VAL, SANITARY INVERTS oft 0 00 GRADE 12" r'!. EXISTING GROUND 24• #020.65" 2.45" 1.65" AIR HOSE AND 1 INLET, ELECTRICAL SUPPLY 7 OUTLETS SANITARY NOTES TP TREATMENT UNIT 1.THE OWTS INSTALLER SHALL HOLD AN ENDORSEMENT FROM THE SUFFOLK COUNTY DEPARTMENT OF HEALTH. FUJIMAC AIR PUMP ON PRECAST CONCRETE PAD 2.ANEXECUTEDOPERATIONANDMAINTENANCECONTRACTBETWEENTHEMAINTENENANCEPROVIDERANDTHE NTS BOX ACCEPTS: SHALL BE PROVIDED TO THE SCDHS TOP VIEW HEAVY COVER#3017-C20 LIGHT COVER#300 3.PROVIDE A 2"VENT PIPE FROM THE OWTS TO THE DWELLING AND CONNECT TO THE SANITARY VENTING WITHIN THE HOUSE GRATE #3017-G20 THE VENT PIPE SHALL BE PITCHED TOWARD THE OWTS SO ANY LIQUID WILL DRAIN TOWARD THE OWTS 6"TALL RISER#3009 4.AN EFFLUENT FILTER SHALL BE INSTALLED UNDER THE ACCESS COVER OF THE CEN5 UNIT ON THE OUTLET PIPE COVER 23.55" /12"TALL RISER#3009-R12 N w ! PROPOSED SEPTIC SYSTEM UP TO 4 BEDROOMS TO GRA E Lv Z FINISHED GRADE MIN,1-OIA. NDCAP TYPE SANITARY DESIGN BY: SDR 3spvc PIPE OREouIv. � LEVELING DEVICE (1)FUJICLEANCEN5500GPD(OWTS) RICHARD M. MATOA.I.A. INLET C) PITCHED 1/S'PER FT c6. IN. MI O) (2)LEACHING POOLS FORDEEP PO BOX 2284 i (1)EXPANSION LEACHING POOLS °'' BOX SEAL, ® ® ® ® 2"INCREMENT, ;��;�:� �- � AQUEBOGUE NY 11931 ` ® ® � TYP. ;;;;.; r:;; POLYLOK SEAL PHONE: (631)523-5879 ® ® ® ® ® ® =''�"' #3001 TYP.40PLCSTYIP. EMAIL: RMATOARCHITECT GMAIL.COM ® ® MIN.12"COMPACTED)SAND OR ® ® ® r ' ® ® ® ® ® .r PEA GRAVEL LEVELING PAD POLYL® ® MATERIAL K 20"DPE FRONT/SIDE VIEW ��1✓D ARC MATERIAL-HDPE 3 ININ e� ,GRDNNDWATER DISTRIBUTION BOX PolYlok DETAILS �5 XPPo M. Q N ro O LEACHING POOL €•% NTS * I TYPICL SILT SCREEN SECTION S�'�T 041 AAv,,6-1•t�O`� GEOTEXNLE FABRIC OF SUPPORT POSTS •• WOOD OR METAL •(��FLOW DIRECTION RICHARD M. MATO A.).A. NYS LISC#047861 EXCAVATED AND BACKFlLI.ED TRENCH DWELLING ELECTRICAL PANEL EXISTING GROUND R 0 O�� -39.27'MAIN - 1 BREAKER I rMINN. DWELLINGS QP� po \ W/PUBLIC WATER 150' 1 .113���Q�Q�J� o CIRCUIT BREAKER - 1 In 'A0, JQ�QF. 0 WAMPQP DEDICATED LECTRICAL SERVICE TO I EL 14.0 HYDROACTION CONTROL PANEL G 233.54' SPIKE HYD. W.V. LOT 9 _ EL 14.8 Tn W.V. EL WO 8'0x6'DEEP 6'CHAINLINK FENCE LP EXP /� CONTROL N 84004'50"E g'Q}x4'DEEP _ CELLAR o (1 '0) 50, 17 `O� PANEL EL 16.5 DRY WELL �t CO ?i�2 O . GAT DP 12'S LP EL 17.0 (16.0) . "MIN o m 8'0x6VEEP o Z :: :20.0' T.H. r m DWELLINGS O O 14' : :'PROPOSED::::;;;•; EL 14.z W/PUBLIC WATER WOOD ::;.:;2 STY FRM.;;.;.;::;:; m EL 14.6 O L 150' D :•:•:::::::•:::•:. .:.. STOOP '::.::DWELLING•::._.:: - O 4 BEDROOMS..• v PROP.WATER LINE O :;:PROPOSED;:.o 'w::... O o::.::EFL(17.-X-:.•,. A VV a O .::.POOL'•:::: a 'Z a EL 16. -ESE E TILITIES E CHAMBER Volume al 19 E PROP.U.G.U x� Sedimentation Chamber 277 LOT 10 t� (15.0) m DEDICATED g•Ox4'DEEP •OE�e 0 Lp GAS ® Anaerobic Filtration Chamber 278 LAND N/F OF OUTDOOR KITCHEN 16 )...i( :::i•:;28.0'':•:•:4' •` (3 Aerobic Contact Filtration Chamber 127 DRY WELL DRY WELL ya ( ® ST PATRICKS CHURCH Clarification Chamber 63 g'0x3'DEEP t �/ Q Disinfection Chamber 4 VACANT 150' 94.5 10, PROP.DRIVEWAY \ Total Volume 749 { :2 Total �„ PROP. 1 ) OUTDO VI 20.0' : >r SEASONAL \��'�� HOW R b / \ SL /IIICOVERED q •::•:GARAGE:.;;o. `P �S SPECIFICATIONS Anaerobic Media PP!PE PRE-CAST SEPTIC ~� ^\ o/OKITHENo a GF(16.5){;?.,i; EL 12.5 EL 11.0 m :...:..... U.P. 8'px6'DEEP 1000 GAL. �C 0 _ '�'�'��• (16.0) Board Type Aerobic Media PVC/PP/PE LP• o Aerobic Media PP I PE 246.62 8ti1/ry S.T. L_----- --� Blower 2.8 cfm o 8'px6'DEEP LP. 8'MIN POOL EDP. J L 15.2 Tank FRP EL 16.5 � f o 'If(`fl��/►► Piping PVC/PP/PE EL 16.8 Access Covers Plastic/Cast Iron N 8304.4'30" Disinfectant(Optional) Chlorine Tablets ✓ Q � I0imuvo T_ FuC, jiCleanUS A LOT 11 a�Toward Clean Water... SCUM BAFFL B I I A U T-1 2'1 2'T 2'-Cj 1 I DWELLING RECIRCULATION `fin J W/PUBLIC WATER I AIR LIFT PUMP f r C/ 100' I ® ISINFECTION CYLINDER(OPTIONAL) ELEV. 74.2 4"INLET PI "OUTLET PIPE OL BROWN I I SANDY LOAM 1.01 I - J 4 Aa JA BROWN - - - - - SM SILTY SAND L 2.3' FFLUENT ZONED R-40 INLET GAFF ® © AIR LIFT PUMP PALE BROWN NON-CONFORMING LOT VACANT © MEDIUM FRONT YARD: 40'MIN 100' SW SAND REAR YARD: 50'MIN LOW BAFFLE _J /4•AIR INTAKE SIDE YARD: 15'MIN 35'TOTAL REVISE HOUSE 4' SOUTH 01-23-25 RECIRCULATION PIP (CLEANING OPENING) B EL 1.5 12.7'P. -FLOW OPENING(TY HIGHEST EXP.WATER EL 2.0 REVISED 01110125 WATER IN MAXIMUM GROSS FLOOR AREA PLAN VIEW SIN PALE 11.78.24 THE WATER SUPPLY, WELLS, DRYWELLS AND CESSPOOL BROWN K.WOYCHUKLS 3,350 S.F. + (10%X3815) = 3,731 S.F. MAX LOCATIONS SHOWN ARE FROM FIELD OBSERVATIONS MEDIUM 20•ACCESS COVE 20"ACCESS COVE 24'ACCESS COVE NFECTION 0'17 SAND _ 2 STY DWELLING W/COVRED PORCH: 1680 S.F. AND OR DATA OBTAINED FROM OTHERS ISI (Typ) (Typ) (7YP) CYLINDER(OPTIONAL) COVER AREA: 23„814.72 SQ.FT. or 0.55 ACRES ELEVA77ON DATUM: NAVD88 PLUG 2'.0" (THREADED) SQUARE g• UNAUTHORIZED ALTERA770N OR ADD177ON TO THIS SURVEY/S A V/OLA77ON OF SECTION 7209 OF 774E NEW YORK STA7F EDUCA77ON LAW. COPIES OF THIS SURVEY a MAP NOT BEARING 77-IE LAND SURVEYORS EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. GUARANTEES INDICATED HEREON SHALL RUN CONCRETE BASE 1' ONLY TO THE PERSON FOR WHOM 774E SURVEY IS PREPARED AND ON HIS BEHALF TO THE 777LE COMPANY, GOVERNMENTAL AGENCY AND LENDING INS777ZI77ON CLEANOUT BOXJI LISTED HEREON, AND TO THE ASSIGNEES OF THE LENDING INSTITUTION, GUARANTEES ARE NOT TRANSFERABLE. ® CLEANOUT THE OFFSETS OR DIMENSIONS SHOWN HEREON FROM THE PROPERTY LINES TO THE STRUCTURES ARE FOR A SPECIFIC PURPOSE AND USE THEREFORE 7HEY ARE ADAPTER ADAPTER NOT INTENDED TO MONUMENT THE PROPERTY LINES OR TO GUIDE THE EREC77ON OF FENCES, ADD177ONAL STRUCTURES OR AND OTHER IMPROVEMENTS EASEMENTS g 30DEGREEFITTINO AND/OR SUBSURFACE STRUCTURES RECORDED OR UNRECORDED ARE NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT THE TIME OF SURVEY 5. © j 4' , SURVEY OF: LOT 10 OF NEW CERTIFIED TO: SLIGO CONSTRUCTION INC.; 4 8 q MAP OF:CO'REY CREEK ESTATES �P�c\A M w�y�oQ FLOW FILED:AUG. 15, 1967 No. 4923 © SEWER LINE x J SITUATED AT: 13AYVIEW CLEANOUT DETAIL ' `• o NTS TOWN OF: SOUTHOLD cT .- ,-,a �- � �� KENNETH M WOYCHUK LAND SURVEYING, PLLC SECTIONA-A VIEW SUFFOLK COUNTY, NEW YORK �0 050882 JQ Professional Land Surveying and Design I' ►rr', r±• P.O. Bog 153 Aquebogue, New York 11931 FILE #224-1135 SCALE: 1"=30' DATE: NOV. 78, 2024 N.Y.S. LISC, NO. 050882 PHONE (631)298-1588 FAX (631) 298-1588 as APPROVED AS NOTED DA B.P.0 FEE BY: NOTIFY BUILDING DEPARTMENTAT 631-765.1802 BAM TO 4PM FOR THE FOLLOWING INSPECTIONS: `RETAIN STORM WATER RUNOFF 1. FOUNDATION-TWO REQUIRED PURSUANT TO CHAPTER 236 FOR POURED CONCRETE OF THE TOWN CODE. 2. ROUGH-FRAMING&PLUMBING 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OFTHE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS ELECTRICAL COMPLY WITH ALL CODES OF INSPECTION REQUIRED NEW YORK STATE&TOWN CODES AS REQUIRED AND CON ITIONS OF SOUTHOLDTO ZBA SOUTHOLD WN PLANNING BOARD SOUTHO TOWN TRUSTEES N•YS.D SO OLDHKC MEMIATI P:ON GOMPLE ;( j OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICATE New York State Law OF OCCUPANCY You Must Call 811 Before You Dig 40' - - - 811 2 1 .21 p�11at?N {rr//�I'i••,.• •f: .'.��.'jN• •Yti:,' �� ..�:. Y ••I:Z S�. L..t'Sw•.:f,.iy •3 .`J iP y:!{'ySr.•.:Ai j•� t.i �'� 4 J •... t..< .. ... 3• .•4`y; - 1 Vl \CV/ ,:�, v ; • '{ti ~ t•• FAFTH DIA 42 DRAIN (TYP.) '"� ';�►:;,h VINYI. �..%w _ CONCPf1� MINIMUM PLOA15 - 12ANP 20' ' •� , ; ,.:z,. NC7r :l�f1GKFlLL MINQUlp�n PULL �f;,::Y•.� ; : I I •;,f.;,. 2 POTTOM ro ref-'5ANO, 12 INCN�5 WIb1N f\OM 5�p. a�'� ;i.:. ".r.1• 0p Orh�,�NON �..�.•. tom... EXPO AWE HAN �% �..:... .� '.� -WALL b�f& # I �W5 PUMP COMPINA110N 5KIMMFp ANn PIL , VACUUM LINE WAStE �IL1Et? !AIC?&LINt CAfC&P\ PUMt' 5KIMMEp GLOX POOL I VALVE CTT.) r OOL PLPN WAT��UM fo INLET VIEW ACP055 C�N�� LM OF HOMP\, L4MffK�n 7 ., t='` �J•'•� —� . : MAIN MAIN PPAIN nl?AIN 12' '/� � OF �+Ewyo STANDARD DETAILS CONC WALL POOL POOL S�CIIJI V A !"\ '�P Q�+ER JA�j PREPARED FOR: SCALE: %6 J � DRAWN BY: C Jd * * DATE: Z/5/2025 REVISED: O SOUTf�Sh0!' POOLS y o 75 �ffiST 11AIN 5T• — PREPARED FOR: 5L160 CONST57 -TION ��fiST I5LlP', NY.11730 800 GO 'GP�ffK POAP 63I-277-�800 0 i�OLT� NY 11�7I PREPARED BY: P EPIO -nJincefIrg S01611ol]5 DRAWING NUMBER: . It is a violation of New York State law for any person, unless they are acting under St 10 0.0rood Lane 5LI60 the direction of a licensed professional engineer, to alter this drawingin an way, P'A6 10>=Z NOTE S; G. POOL MUST DE EQUIPPED WITH AN APPROVED POOL ALARM GAPWDLE OF DETECTING W CHILD ENTERING THE WATER AND 1. NO SPOIL SURCf1ABGE PERMITTED V101IN 4 FEET OF EXCAVATION AT THE SHALLOW END,OR G FEET OF 50UNOING AN AUDIDLE ALARM WHEN DETECTED THAT l5 AUDIDLE AT POOL-SIDE AND IN51PE THE DWELLING WHERE THE POOL 15 EXCAVATION AT THE DEEP END. LOCATED, THE ALARM MU57­DE 11\1STA1_1_ED,MAINTAINED AND USED IN ACCORDANCE WITH THE 11ANUFACTUBER51N57­BUGTIONS, 2. TH15 POOL MMETS THE PfOUIREMENT5 OF AN5//N5PI-5"AI1E8/CAN NATIONAL 5TMI0AB0 FOB RESIDENTIAL THE ALARM MU5T MEET ASTM F2208"STANDARD SPECIFICATION FOR POOL Al -5, THE DEVICE MUST OPERATE IN6ROUND 5W/MM.lN6 POOLS"AND l�G DOGA CODE-SECT/ON 42/. DlV1N6 EQUIPMENT I5 NOT PERMITTMD, INDEPENDENT(NOT ATTACHED TO OR DEPENDENT ON)OF PERSONS,,'7ULTIPLE Al-ARM5 MAY DE REQUIRED TO ADEOUA77ELY 3. ALL ELECTRICAL V✓ORK SHALL COMPLY WITH THE RMOUIREMENTS OF NFPA 70(NEC),PR/NGIPALLY ARTICLE 680. P'��EGT CERTAIN 51 POOLS ALL POOL ELECTRICAL EQUIPMENT SHALL DE PROTEGTMD DY A UL LISTED 6FGl. 7, WATER SOURCE FILLING THE POOL SHALL DE EQUIPPED WITH A DAGKr�LOW PROTECTION DMVIGE. 4, DURING THE lNST,�LLATlON OR GONSTRUGTION OF THE SWIMMING POOL,THE POOL MUST DE ENTIRELY 8, A MEANS OF E68E55 FOR DEEP AND SHALLOW ENDS MUST DE PROVIDED lAW AN5//NSPI-5 SECTION G, ENGL05MD DY A TEMPORARY DARRIER,THE TEMPORARY DARBIER MAY DE A TEMPORARY FENCE,A PERMANENT C• CONTRACTOR SHALL PLACE THE POOL ON THM LOT lAW TOWN OF SOUTHOLD CODE, ALL REQUIRED SETDAGKS AND MAXIMUM GOVERA6M5 SHALL DE MAINTAINED, FENCE,THE WALL OF A PERMANENT 5TRUCTUBE;ANY OTHER STRUCTURE`,OR ANY GOMDINAT/0I\1 OF TH05M. EB:rHE TE,'7PORARY GABBIER MUST; 10. ALL PIPING l5 DIAGRAMMATIC UNLE55 OTHERWISE STATED, ALL PIPING TO DE POLYETHYLENE. HowMV 11, WALKS,IF PROVIDED SHALL DE NONSLIP AND SLOPE AWAY FROM POOL ED6E, 4.1, EV AT LEAST FOUR(4)FEET HIGH 4.2, PREVENT ACCESS TO T,hE 5W1MMlN6 POOL DY ANY PER50N NOT lNSTALL(N OR CONSTRUGTING THE !2. ALL DRAINAGE FROM THE POOL SHALL DE MAINTAINED THE SUDJEGT PROPERTY, POOL l3. POOL AREA 80050FT,PERIMETER lZO`VOLUNM 22,000 GALLONS. 43. REMAIN IN PLACE UNTIL W PERMANENT POOL GABBIER l5 PROVIDED 14, THE DE5/6N l5 DASED ON A DRAINAGE 50/L WITH.107 51LT AND ASSUMED OEAPING CAPACITY OF 9,000 P5F. GROUND WATER 4.4. DE REPLACED DY A PERMANENT POOL GABBIER V✓/THIN 5 PPO ; SHALL NOT EXIST WITHIN THE EXCAVATION. IF GROUND WATER EX15T5 WITHIN GO"FROM 6RADE.SPECIAL DEWATERIN6 FACUT'IE5 4,41 90 DAY5 OF THE DATE OF ISSUANCE OF THE OUILDING PERMIT FOR THM INSTALLATION OR WILL DE REQUIRED. GONSTRUGTION OF THE SWIMMING POOL.:OR 1�, S:JGT(ON FITTINGS FOR USE IN 5W(NM1N6 POOLS SHALL COMPLY WITH REFERENCE STANDARD ASME/AN5/AI12,19.8,SEE 4.4.Z. CO DAYS OF THE DATE OF GOMMNG POOL., OF THM INSTALLATION OR GONSTRUGTIOI�OF THE RESIDENTIAL CODE OF NEV'✓YORK STATE R326,6, POOL SUCTION F1TTIN65(EXCEPT FOR SURFACE SKINNERS)MU5T DE 5WDAY_'5 POOL. PROVIDED W(TH A COVER THAT GONFORl75 TO ASME/AN51 A112,19.8 OR A MINIMUM 12"X 12"0RA/N.6RATE. POOL CIRCULATION 5W1M11NG POOL SHALL DE COMPLETELY AND CONTINUOUSLY SURROUNDED WITH A DARRIER THAT COPIPLIES 5Y5T EM MUST DE EOUIPPED VV1Th AN ATMOSPtl fPIG VACUUM REL/MF IN THE EVENT THE GRATE COVERS LOCATED W(TH1N THE W17-11 THE FOLLOWING; POOL OECOME M155/N6 OR DBOKEN, SUCH VACUUM BELIEF 5Y57­EM5 SHALL GONFOBM WITH A5ME A112.19.17 OR DE A GRAVITY n,1. THE TOP OF THE OARRIER SHALL DE AT LEAST 48/NGHES AOOVE GRADE A5/7EA5URED FROM THE 5Y5T MI'1 APPROVED OY THM LOGAL JURISDICTION, POOL SHALL DE PROVIDED WITH A MINIMUM OF 2 SUCTION FITTiN65 OF THM OLrTSIDE OF THE FENCE. AOOVE MENTIONED TYPE,THE SUCTION F17_T1NGS SHALL DE 5EPARATED OY A MINIMUM OF 3'AND MUST DE PIPED SUCH THAT n,2, MAXIMUM VERTICAL CLEARANCE FROM GRADE TO THE DOTTOM OF THE FENCE l5 2"A5 MEASURED ON WATER l5 DRAWN THROUGH THEM 51/1UL7­ANEOUS1_Y THROUGH A VACUUM RELIEF-PROTECTED LINE TO THE PUMP(OF PUMPS), THE OUT5/0E OF THE FENCE. VACUUM/PRM55URE GLEANING FITT(N65 SHALL DE IN AN ACCE55JDLE PC5I7-ION, MINIMUM OF G"AND NO GREATER THEN 12" 5,3, OPENINGS IN THM GABBIER SHALL NOT ALLOW THE PASSAGE OF A 4"SPHERE. DELOV✓THE MINIMUM OPERATIONAL WATER LEVEL OR DE AN AT7­AG11l1ENT TO THE SKIMMER/S,CIMMERS. n,4, 50L(D DABRIERS WITHOUT OPENINGS(SUCH AS 17A5ONRY OR STONE)SHALL NOT C NTIklN ANY /6, ALL GA5 AND OIL-V✓ATER HEATERS(IF INSTALLED)FOR THE IN-GROUND 5W1MM1NG POOL SHALL DE NATIONAL APPLIANCE INDENTATIONS OR PROTRUSIONS THAT COULD ACT A5 A FOOTHOLD EXCEPT FOR NORMAL ENERGY CONSERVATION ACT(NAEGA)COMPLIANT, POOL HEATERS SHALL DE TESTED IAW AN51 Z2/,5)G AND SHALL OE INSTALLED CONSTRUCTION TOLEBANGES AND TOOLED MASONRY JOINTS, lWW MANUFACTURERS SPEC1F1CAT1ONS. OIL FIRED POOL HEATERS SHALL DM TESTED IWV✓UL726. POOL HEATERS SHALL DE 5,5, WHEN THE DAPPlER l5 GO11P05E0 OF HORIZONTAL AND VERT/GAL MEMDE85 AND THE D/STANCE LOCATED OR GUARDED TO PROTECT AGAINST ACCIDENTAL CONTACT OF HOT---AJBFACES DY PE850N5. POOL HEATERS SHALL DETWMEN THE TOPS OF THE HORIZONTAL MEI7DEB515 LE-5-5 THAN 4n"THE HORIZONTAL MENDERS DE PROVIDED WITH TEMPERATURE AND PRE55U,r'E-RELIEF VALVES. FOR HEATERS NOT PROVIDED V✓ITH AN 1N7_E68A1_DYPA55 SHALL DE ON THE lN5/DE(POOL SIDE), HEATERS A DYPA55 LINE SHALL DE INSTALLED FROM INLET TO OUTLET TO ADJUST WATER FLOW THROUGH THE HEATER, POOL S,G. SPACING DETWEMN VERTICAL MENDERS SHALL NOT EXCEED 1-3/4"1N WIDTH, WHERE DEGORATNE HEATERS SHALL DE PROVIDED WITH THM FOLLOV✓/NG ENERGY CONSEWATION I1EA5URE5: GU'TOUTS EXIST THE CUTOUTS SHALL NOT EXCEED 1-3/4"IN WIDTH, THE ALL POOL HEATER5 SHALL DE MQUIPPED WITH AN ON-OFF SWITCH MOUNTED FOR EASY ACGE55 TO ALLOW SHUTTING OFF n.7. MAXIMUM MESH 5/ZM FOR GRAIN LINK FENCES SHALL DE 2-1/4"50UAC'E UNLE55 THE FENCE HA5 THE OPERATION OF THE HEATER WITHOUT ADJUSTING THE THERMOSTAT SETTING AND TO ALLOW RESTARTING WITHOUT SLATS, RELIGHTING THM PILOT LHl6T. �,8, WHERE rHE D,N'R1ER 15 GOMP05ED OF DIAGONAL MENDERS CSUGH AS W LATTICE FENCE)THE MAXIMUM 16.2 11EA77ED 5WIMMII G POOLS SHALL DE EQUIPPED WITH A POOL COVC'R(EXEMPTED FROM THl5 REOUIREMENT ARE OUTDOOR OPENING FORMED DY THE DIAGONALS SHALL NA 1-3/4" POOLS OEBNIN6 20%OF THE ENERGY FOR HEATING FROM RENEW✓ADLE 50URGE5,A5 COMPUTED OVER AN OPERATING n.9. GATES SHALL COMPLY WITH THE CONSTRUCTION REOUIBEMENTS AS ADOVE, IN ADDITION: 5 59.1. ALL GATES SHALL DE SELF CLOSING AND OPEN OUTWARD(AWAY)FROM THE POOL. AND 3 TIME ME CLOCKS SHALL DE INSTALLED 50 THE PUMP CAN DE 5fT 7-0G RUN DUR1N6 OFF-PMAK ELECTRICAL DEMAND PER10D5, . �9,2, ALL GATES SHALL DE SELF LATCHING WITH T HE LATCH HANDLE LOGATMD ON THE POOL SIDE OF AND CANOE 5CT TO RUN THE MINIMUM TIME NECESSARY TO MAJMT'AIN THE POOL WATER IN A GLEAN AND 5ANITARY CONDITION/A V ENCLOSURE AND AT LEA5T 40 INCHES ADOVE GRADE, IF THE LATCH HANDLE lD LOCATED LE55 11 T/ICADLE SANITARY CODE OF NEW YORK STATE. THAN 554!NCHES FROM THM DOTTOM OF THE GATE,THE LATCH SHALL DE LOCATED AT LEAST 3" 17. THE POOL WA5 DEIAL CO D lAW THE FOLLOWING: DELOW THE TOP OF THE GATE AND NEITHER THE GATE NOR THE GABBIER SHALL HAVE ANY OPENING 17,1 2020 RESIDENTIAL CODE OF NEW YOBK STATE. GREATER THAN 0,5 II�GHES W1TH/N l8"OF THM LWTGH HANDLE, 172 WN5//NSPI-�STANDARD FOR RMS/DENTIWL IN-GROUND SWINMIN6 POOLS n.93. ALL GATE-5 SHALL OE SECIJBELY LOCKED WITH A KEY OR COMDII`rAT(ON OR OTHER CH/LD PROOF LOCK !73 CODE OF THM TOWN OF 50UTHOLD 5UFFIGIENT TO PREVENT AGCE55 TO THE POOL THBU SUGH GATE WHEN TOE POOL l5 NOT IN USE OR SUPERVISED, 55./0. WHEN THE WALL OR WALLS OF A DWELLING FORM PART OF THE OARRiER THE REOU(REMENT5 OF R326,42,1 TH,BU 8326.42,G APPLY IN ADDITION TO ONE OF FOLLOWING CONDITION-5 OF ZV6,42,8.5/1ALL DE MET.• DOORS V✓ITH DIRECT ACCESS TO THE POOL SHALL DE ALARMED. SPEGIFIGATION5 ARE PER o N E k,y STANDARD DETAILS- C 0 N C WALL POOL R326.4,2.81,o)h'JD ,`P NER d q 0,p 5.10.0.2, WINPOV15 A5 SPECIFIED IN R32G.4,2,81,b)AND y Q �c�` 'f� SCALE. DRAWN BY: cjd PREPARED FOR: 5,10.0.3. WHEN THE DV✓ELLING/5 WHOLLY CONTAINED WITHIN THE POOL GABBIER ALARM5 SHALL DE * O * DATE: 2/5/2025 REws�ED: SOUTH 5h01��POOLS PROVIDED PER R326.42,8/,c)OR 00 ¢ 75 f 5T MAIN 5T, �.lo.l. OTHER APPROVED MEAN5 OF PROTEGTION PER R32G.42.8 2, — -� le► PREPARED FOR: 5L160 GONSTPUGTION EAST lSLlf , NY 11730 z 800 COPE Y G1'flffK POAD 6.31-277-9800 07989, OUThOLD NY 11971 AR PREPARED BY: J�,ffpro Engineering 5o/ullon5 DRAWING NUMBER: It is a violation of New York State law for any person, unless they are acting under the �F�SS10N /0 00YWood Lane 5L160 direction of a licensed professional engineer, to alter this drawing in any way. l'ifi6E 2 OF 2