Loading...
HomeMy WebLinkAbout52952-Z �o��of souryo`o Town of Southold * P.O. Box 1179 �p 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 47182 Date: 06/30/2026 THIS CERTIFIES that the building As built apartment in accessory building Location of Property: 2175 Pine Neck Rd Southold, NY 11971 Sec/Block/Lot: 70.-5-48 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 11/06/2025 Pursuant to which Building Permit No. 52952 and dated: 05/06/2026 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: As built conversion of an existing accessory building into an accessory apartment as applied for per ZBA#8005SE dated 5/15/2025. The certificate is issued to: Alexander Lindh Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: R-25-1417 10/28/2025 ELECTRICAL CERTIFICATE: 2026-1170620 4/28/2026 PLUMBERS CERTIFICATION: Ethan Romanelli 6/25/2026 �uthor�eSignature 1V �a0F30pTHo TOWN OF SOUTHOLD BUILDING DEPARTMENT N ' t SOUTHOLD, NY ,o BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52952 Date: 05/06/2026 Permission is hereby granted to: Alexander Lindh 282 County Rd Cresskill, NJ 07626 To: Legalize converting an accessory building into an accessory apartment as applied for per SCHD and ZBA approvals. Premises Located at: 2175 Pine Neck Rd,Southold, NY 11971 SCTM#70.-5-48 Pursuant to application dated 11/06/202S and approved by the Building Inspector. To expire on 05/05/2028. Contractors: Required Inspections: DRAINAGE, FOOTING/REBAR, FOUNDATION 1ST, FOUNDATION 2ND, FRAMING/STRAPPING, PLUMBING, ELECTRICAL-ROUGH, FIRE RESISTANT PENETRATION, ELECTRICAL-FINAL, INSULATION, FIRE SAFETY INSPECTION, FIRE RESISTANT CONSTRUCTION, FINAL, Fees: As Built Apartment in Accessory Building $1,045.00 CO-RESIDENTIAL $100.00 ✓ Total 1145.00 V� Building Inspector # '~ �,�. �L. � y�"`a mil- �'_� !J� `� i•"• "'` E�L �`', ,/,f�4���"^<. f1 I -ic I I/ spe tors, ecti Inc. 2026-1170620 Southold,Town Of ■ Inspector: 115 iew York Board of Fire Underwriters Issue Date:4/28/2026 00 East Meadow Avenue t Meadow,NY 11554 i& Office:(516)794-0400 1 110200 Website:www.eiiny.coi Mail To: Property Address: Alexander Lindh Alexander Lindh 2175 Pine Neck Road 2175 Pine Neck Road Southold NY 11971 Southold NY 11971 -�CM ELECTRICAL A PPR 0 VA L CER TIFICA TE Secfion: 1000 Block:70 Lot: 5-48 Permit: AREAS LISTED BELOW ARE APPROVED BY One Time Survey AND FOUND TO BE IN COMPLIANCE WITH THE BUILDING CODE OF NYS AND CURRENT PROMULGATED NEC No visual defects were found for the electrical inspection provided No obvious unsatisfactory conditions were found in the areas herein below only. Residential One Time Survey Approved 4/21/2026 fryFirst Floor.Bathroom 1,Bedrooms 2,Boller Room 1,Family Room 1,Laundry 1,Kitchen 1.* This electrical Inspection and certificate does not take into account any FEMA,NYS and local flood elevation requirements.It Is the responsibility of the property owner to determine if flood elevation fsa� ents apply. NYBFU and Ell are not responsible for any Flood Elevation requirements R1 R1 ;l Therefore this electrical certificate Is only for compliance of NYS Electrical and NEC Codes. 4 K Richard M. Bivone PhilipGoehi�ig, Jr. N President Chief -Electrical Inspector This document features a tamper proof Quick Response code which contains the encrypted original data submitted when certificate was Issued. (L fl,A Alt -e r ' FFO Town Hall Annex �� y Telephone(631)765-1802 54375 Main Road P. O. Box 1179 h Southold, NY 11971-0959 W- • E C E 0 U E BUILDING DEPARTMENT TOWN OF SOUTHOLD JUN 2 5 2026 Building Department CERTIFICATION Town of Southold Date: g Building Permit No. 0 Owner: Al e.X0,N A Q-v' ti r C�l• (Please prin 11 Plumber: (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1%lead. (Plumbers Signature) Sworn to before me this05 r' day of:`A d:�sg 20 0 Notary Public, County CONNIE D.BUNCH Notary Public,State of New York No.01BU6185050 Qualified In Suffolk County Commission Expires April 14,2 � OF SOUTyolo # * TOWN OF SOUTHOLD BUILDING DEPT. `yCourm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ FINAL AS- hii lT1 [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: tr�c c��h - �ewc �v tic Sol" Cop&j 40AA �JA,u C"Jodr\ wimcljt cj&kt�tyl 7� U�b-fid 4, 0,0 02 �SDh DATE !�-_a -494 INSPECTOR AMP Architecture Address:10200 Main Road,Unit 3A,Mattituck NY 11952 Phone:(631)603-9092 Design + Build June 181h 2026 :.'l E C E � V E Lindh Residence J U N 2 9 2026 2175 Pine Neck Road Southold,NY 11971 Tax map#1000-070.00-05.00-048.000 �3vaid;�ag'�Qa�rtr��v�� Town of 8outhri!d To Whom It May Concern. Based on my inspection at the above address the framing was completed per the architectural plans and meets NYS Building Code. Please contact our office if you have any questions. Thank you, Anthony Portillo,RA,LEED AP FLED A M. o F O yj. �a7aoy O FOF NE`�y Page 1 of 1 A M P Arch i t e c t u re Address:10200 Main Road,Unit 3A,Mattituck NY 11952 Phone:(631)603-9092 Design + Build June 18th 2026 Lindh Residence 2175 Pine Neck Road Southold,NY 11971 Tax map#1000-070.00-05.00-048.000 To Whom It May Concern. Based on my inspection at the above address the plumbing was completed per the architectural plans and meets NYS Building Code. Please contact our office if you have any questions. Thank you, Anthony Portillo,RA,LEED AP (� �9 �j l5 C E i! U " µED q � 9j. 037405 yp FQFNE� Building Departmen-1 Tdwn of Southold Page 1 of 1 . AM P Arch i t e c t u re Address:10200 Main Road,Unit 3A,Mattituck NY 11952 Phone:(631)603-9092 Design + Build June 18"2026 Lindh Residence �p l� 2175 Pine Neck Road 0 V E Southold,NY 11971 Tax map#1000-070.00-05.00-048.000 1 JUN 2 9 2026 To Whom It May Concern. Building Department Based on my inspection at the above address the insulation was complaim$OtWhrld architectural plans and meets NYS Building Code. Please contact our office if you have any questions. Thank you, Anthony Portillo,RA,LEED AP EtED A \y� V M. * f. O 33740y AO� FOF NEN Page 1 of 1 Dwyer, Tracey From: Alex Lindh <alindh1 @gmail.com> Sent: Saturday, May 2, 2026 1:46 PM To: Dwyer, Tracey Subject: Re: building dept 2175 Pine Neck Hi Tracey-please see below: https:Hparts.andersenwindows.com/resources/pdf/400TWSizeGrid.pdf?srsltid=AfmBOop6 - 116lc7lbXOsEo569bfouielC ukdisUh6 gle4dJ29vFD The egress window is this one: Andersen:TW21046 Unobstructed glass equals>5 square ft. Thanks, Alex On Fri, May 1, 2026 at 15:23 Dwyer,Tracey<tracev.dwver@town.southold.ny.us>wrote: Please send me the make and specifications for the windows via this email. From:Alex Lindh <alindhl@gmail.com> Sent:Tuesday,April 21, 2026 1:46 PM To: Dwyer,Tracey<tracev.dwver@town.southold.nv.us> Subject: Re: building dept 2175 Pine Neck Hi Tracey, Thank you for your patience. I am writing to confirm that the bedroom window in the accessory apartment at 2175 Pine Neck meets the required code for egress on grade, with a clear opening of 5 square feet. Please accept my apologies for the delayed response, as your previous message had unfortunately been buried in my inbox. I called the Building Department today and spoke with a representative who directed me to your email so that I could provide this verification. Could you please let me know the next steps in the process and the current timeline for an inspection of the as-built accessory apartment? 1 FIELD INSPECTION REPORT I DATE COMMENTS ro FOUNDATION (IST) 9 ------------------------------------ x Vn FOUNDATION (2ND) W z Zs ROUGH FRAMING& 5 PLUMBING p � r INSULATION PER N.Y. STATE ENERGY CODE FINAL D Ole, Ate CD" eeso ro .? 04 12 ADDITIONAL COMMENTS (o"- a 6" Rkm z m 1 O z G � � x o�g11FF0lKcoG TOWN OF SOUTHOLD—BUILDING DEPARTMENT y2 H Town Hall Annex 54375 Main Road P. O.Box Ir79 Southold,NY 11971-0959 Telephone`(631)765-1802 Fax'(631)765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For offtce use'omy k I -PERMIT-No.53N 5 4o— 'Building Inspector: NOV 6 20L"J Applications and forms must be filled out in their entirety.Incomplete applications'will not be accepted. Where the Applicant is-not the owner;'an Building Dex�acfienent Owner's Authorization form(Page 2)shall be completed. `four,, o;sou°.3-1old Date: ZO 25 OWNER(S)OF PROPERTY: Name: SCTM#1000- Project Add ress -....�� ' SV,KA— G.L Phone#: _. ._Mi _'_V�_ ?0U4 __.._ __._-.._. - _ __... Email: �i,�� _ __Q._ !��.�__.•.(,Ow�._ __ . _._.__ _._ Mailing Address: CONTACT PERSON: Name: Mailing Address: Phone#: g 5— _.7-15- �..7a.6 b_.._ .__.__._ Email: _. _ � _._ �__ .rw_�•_I___ _.0� _. DESIGN PROFESSIONAL //INFORMATION:^ Name: . _..►V. .. ..- ._._f3._.___ . �,1 ... . Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: — Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of P1cf t: Other PiCe-G w- v Pt CAS b ` $ �Anl}c Oti Will the lot be re-graded? ❑Yes)(No Will excess fill be removed from premises? ❑Yes 3(No 1 PROPERTY'INFORMATIM Existing use of property: .I�kC 550�_ - -_/... Intended use of property: Zone or use districtin which premises issitwated: Are there any-covenants-and restrictions with respect to - this property? (]Yes`�(,No IF YES,PROM DE.A COPY.• XCheck Box After Reading: The owner/contractor/design professional Is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Coda: APPLICATION IS HEREBY MADE to the Iluilding.Dapartment for the(Issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances of Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized Inspectors on premises and In buildings)for necessary,Inspections.False statements made heroin are punishable as a Class A misdemeanor pursuant to Section- 10AS of the Now York State penal taw. Application Submitted By(print name): A eIos DAuthorized Agent wner Signature of Applicant: Date: STATE OF NEW YORK) S - COUNTY OF 'S U y being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the ® f!r (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,-and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. S ern,before me this day of no .2025 N ry lic ItdEIVA.STAM NaN Public,State of tkw Vsk No.01ST5070979 PROPERTY OWNER AUTHORIZATION QualliflsdlriSleff+&14Udt (Where the applicant is not the owner) I, residing at do hereby author' to apply on my behalf to the Town of Southold B ' ng Department for approval as cribed herein. Owner's ' ature Date Print Owner's Name 2 BOARD MEMBERS ��OF SO(/jyD Southold Town Hall Leslie Kanes Weisman, Chairperson 53095 Main Road-P.O. Box 1179 Patricia Acampora Southold,NY 11971-0959 - Robert Lehnert,Jr. en Office Location: • a0� Town Annex/First Floor Nicholas Planamento Margaret Steinbugler if'�out�,�� 54375 Main Road(at Youngs Avenue) Southold,NY 11971 http://southoldtownny.gov 10 57 I7'-"' ZONING BOARD OF APPEALS MAY 21 2025 TOWN OF SOUTHOLD Tel. (631)765-1809 rho9d FINDINGS, DELIBERATIONS AND DETERMINATION - _ - - - MEETING OF MAY.15,2025 ZBA Application No.: 8005SE Applicants/Owners: Alexander Lindh and Courtney'Bancroft Property Location: 2175 Pine Neck Lane, Southold,NY SCTM No. 1000-70-5-48 SEORA DETERMINATION: The Zoning Board of.Appeals has visited the property under consideration in this application and determines that this review falls under the Type II category of the State's List of Actions, without further requirements under SEQRA. SUFFOLK COUNTY ADMINISTRATIVE CODE:This application was not required to be referred to the Suffolk County Department of Planning under the Suffolk County Administrative Code Sections A 14-14 to 23. LWRP DETERMINATION: The special exception requested in this application is listed under the Minor Actions exempt list and is not subject-to review under-Chapter 268. REQUEST MADE BY APPLICANT: The Applicant-Owner requests a Special Exception under Zoning. Code Section 280-13(B)(13)to legalize an as-built Accessory Apartment in an existing accessory structure. PROPERTY FACTS/DESCRIPTION:The subject property is a non-conforming 17,126.36 square-foot parcel in the R-40-Residential-Zoning'District.-The parallelogram-shaped property-runs-100 feet along - Pine Neck Road,then 178:36 feet north adjacent to the neighboring residential parcel-to the east,then 100 a!ong an east-west running private right-of-way to the north,then 175 feet south,adjacent toAhe neighboring residential parcel to the west, back to Pine Neck Road. The parcel is improved with a two- story single-family dwelling,an in-ground swimming pool, a wood deck, a frame shed,and an accessory garage, as shown on a survey prepared by Michael J.Scalice, Scalice Land Surveying,dated November 6, 2020. ADDITIONAL INFORMATION: An as-built habitable conditioned space was constructed in the subject accessory garage by-a previous owner without the benefit of a building permit. The special exception requested is to legalize this space,to be rented to the owners' parents-in-law/parents. The applicant submitted a plot plan prepared by David Turner,Architect, P.C.,.consisting of pages A- 100.00, Sewage&Leaching Plan, 217-5 Pine Neck Road, Southold,dated June 4,2021;A-100.01,a signed and sealed version of A-100.00 last updated March 25,2022; and A-101.00, Floor Plans 2175 Pine Neck Road, Southold,dated June 4,2021,depicting a room labeled"Utilities" in the accessory structure. Page 2,May 15,2025 #8005SE,Alexander Lindh and Courtney Bancroft SCTM No. 1000-70-5-48 The applicant submitted a floor plan of the accessory structure prepared by Anthony Portillo,,Architect, dated January 29,2025 depicting a room labeled"Heater Room"and indicating the apartment has 726.5 square feet of livable floor area. The Southold Building Inspector determined the apartment livable floor area to be 795 square feet which includes the Heater Room,as noted in"Verification of Livable Floor Area"submitted to the ZBA, received April 7,2025. FINDINGS OF FACT The Zoning Board of Appeals held a public hearing on this application on May'l,2025 at which time written and oral evidence were presented.Based upon all testimony,documentation,personal inspection of the property and the surrounding neighborhood,and other evidence,the Zoning Board finds-the_. following facts to be true and relevant. SPECIAL EXCEPTION FOR AN ACCESSORY APARTMENT In considering this application,the Board has reviewed the code requirements set forth pursuant to Article III, Section 280-13(B)(13)to establish an Accessory Apartment in an accessory structure and finds that the applicant complies with the requirements for the reasons noted below: 1.The Accessory Apartment unit is located in a single-story accessory structure with a non-conforming 795 square feet of livable floor area. 2. The Accessory Apartment complies with the definition of same in§280-4 of the code and complies with all code requirements as defined in Section 280-13(B)(13)of the Zoning Code except for the size of the apartment. Per the Building Inspector's"Verification of Livable Floor Area'.'dated as received by the ZBA April 7,2025,the total livable floor area of the Accessory Apartment is 795 square feet,which exceeds the permitted livable floor area by 45 square feet.The difference between the 726.5 square feet of livable floor area in the floor plan.prepared by Anthony Portillo,Architect,dated January 29,2025,and the 795 square feet of livable floor area determined by the Building Inspector can be accounted for by the area of the room.labeled"Heater Room"in the former and labeled"Utilities"in"Floor Plans 2175 Pine Neck Road, Southold,"prepared by David Turner,Architect, P.C.,dated June 4,2021. 3. The accessory structure does comply with-the-code requirement as,-defined in Section 280A3(B)(13)(e). of the Zoning Code which states the accessory structure must have been certificated a minimum of three years prior to the establishment of the Accessory Apartment. On June 5, 1996 Lois L. Dunne, the prior owner, was issued Certificate of Occupancy No. Z-24398 for the subject accessory garage pursuant to Building Permit No.23379-Z for"alter an existing accessory garage to a`non-habitable.' studio and storage space to include a bathroom and attached heater room with an attached deck as applied for" and on June 19, 1996 was issued Certificate of Occupancy No. Z-24446 for the subject accessory garage pursuant to Building Permit No. 7585-Z for"accessory garage as,applied for." Consequently,the Board-finds that the = structure has been certificated for greater than the minimum required three years prior to establishing it as an Accessory Apartment. 4. The applicant owns and resides at the property and will continue to occupy the single-family dwelling as a principal residence in conformance with the code requirements as set forth in Article III, Section 280- 13(B)(13)(i, 1-4)as documented by a.driver's license and an electric bill. Page 3,May 15,2025 #8005SE,Alexander Lindh and Courtney Bancroft SCTM No. 100040-5-48 5. The occupant of the Accessory Apartment will be either a family member or a resident who is currently on the Southold Town Affordable Housing Registry, and the occupancy shall not exceed the number of persons permitted, in conformance with the code requirements as set forth in Article III, Section 280- 13(B)(13)(i, 1-4). The applicant testified that the tenants of the Accessory Apartment will be the parents of his wife, Courtney Bancroft, as evidenced by a lease indicating Alexander Lindh as landlord and Scott Bancroft and Madeleine Bancroft as tenants, and a copy of a certificate of birth and baptism indicating Scott-Joseph Bancroft and Madeleine Mehiel as parents of Courtney-Faith. 6. The owners' plans comply with the on-site parking requirements of three spaces, two for the principal dwelling and one for the Accessory Apartment. A sketch on a survey prepared by Michael J. Scalise, Scalise Land Surveying,dated November 6,2020 indicates a total of five parking spaces are available. Site inspection also verified the availability of five spaces. 7. Only one Accessory Apartment will be on the subject property and no Bed and Breakfast facility, as authorized by Section 280-13(B)(14) hereof, shall be permitted in or on premises for which an Accessory Apartment is authorized or exists. 8.This as-built Accessory Apartment shall be subject to a building permit, inspection by the Building Inspector,and annual renewal'of the Certificate of Occupancy in accordance with Chapter 280-13(D). REASONS FOR BOARD ACTION DESCRIBED BELOW: Based upon all testimony, documentation, personal inspection of the property and surrounding neighborhood, and other evidence, the Zoning Board finds the.following facts to be true and relevant: 1. The Accessory Apartment, as applied for, is reasonable in relation to the district in which is located, adjacent use districts,and'nearby adjacent residential uses. 2. This Accessory Apartment shall be in conjunction with the owner's residence in the primary dwelling, and as proposed will not prevent the orderly and reasonable use of districts and adjacent properties. 3.No evidence has been submitted to show that the safety,health,welfare, comfort,convenience,order of the Town would be adversely affected. 4.The special exception is authorized under the Zoning Code through the Zoning Board of Appeals as noted herein,and issuance of a Certificate of Occupancy from the Building Inspector is required by code before an Accessory Apartment may be.occupied. 5.No adverse conditions were found after considering items listed under Sections 280-142 and 280-143 of the Zoning,Code. RESOLUTION OF THE BOARD: In considering the entire record and the applicable code requirements, motion was offered by Member Steinbugler seconded by Member Weisman (Chairperson), and duly carried,to GRANT the Special Exception Permit for an Accessory Apartment measuring 795 square feet, SUBJECT TO THE FOLLOWING CONDITIONS: 1. This Special Exception Permit requires an annual renewal by a Code Enforcement Officer. It is the applicant's responsibility to apply to the Building Department each year to renew the Accessory Apartment permit. Failure to do so may require a public hearing before the Zoning Board of Appeals to review potential action to revoke the Special Exception Permit granted herein. 2. This Special Exception permit cannot be transferred to new owners. Page 4,May 15,2025 #8005SE,Alexander Lindh and Courtney Bancroft SCTM No. 1000-70-5-48 3. When the subject Accessory Apartment is not being occupied by the applicants' parents-in-law / parents,as applied for,the Accessory Apartment may not be rented to or occupied by anyone else. 4. The applicant shall submit a signed and sealed floor plan by a licensed professional of the Accessory Apartment,with a revised data table reconfiguring the size to measure a total of 795 square feet. 5. Per Town Code, the applicants may not rent their principal dwelling or apply for a permit to establish a bed-and-breakfast use as long as the Accessory Apartment approved herein exists. - 6. That the above conditions be written into the Building,Inspector's Certificate of Occupancy, when issued. Any deviation from the survey, site plan and/or architectural drawings cited in this decision, may result in delays and/or a possible denial by the Building Department of a building permit, and may require anew application and public hearing before the Zoning Board of Appeals. In the event that this is a special permit subject to conditions, the approval shall not be deemed effective until such time that the foregoing conditions are met; and failure to comply therewith will render this approval null and void. Any violations of the conditions, occupancy or other requirements described herein, may require a public hearing before the Zoning Board of Appeals to review potential action to revoke the Special Exception Permit granted herein. Vote of the Board: Ayes: Members Weisman (Chairperson), Acampora,and Steinbugler. (3-0)(Member Lehnert absent,Member Planamento recused) AREA VARIANCE FOR EXCEEDING TOTAL LIVABLE FLOOR AREA Regarding the required VARIANCE RELIEF for exceeding maximum livable floor area by 45 square feet for an as-built Accessory Apartment(total livable area is 795 square feet)where the code permits a maximum square feet of livable floor area of 750.square feet,the Board-finds that: 1. Town Law 4267-b(3)(b)(1). The requested relief will not adversely affect the character of the neighborhood or be a detriment to nearby properties because the Accessory Apartment is only 45 square feet more than the maximum the code permits, which is attributable to the inclusion of an"as built"utility room, is not discernable,from the interior or exterior of the structure,and has apparently contained this floor area since 1996. 2. Town Law&267-b(3)(b)(2). The benefit sought by the applicant cannot be achieved by some method, feasible for the applicant to pursue,other than an area variance because the Accessory Apartment in the converted garage currently exists"as built."The applicant does not propose any expansion of the existing apartment. 3.Town Law 4267-b(3)(b)(3). The variance granted herein is not mathematically substantial, representing just 6%relief from the code. 4.Town Law 4267-b(3)(b)(4). No evidence has been submitted to suggest that a variance in this residential community will have an adverse impact on the physical or environmental conditions in the neighborhood. The applicant must comply with Chapter 236 of the Town's Storm Water Management Code. Page 5,May 15,2025 #8005SE, Alexander Lindh and Courtney Bancroft SCTM No. 1000-70-5-48 5. Town Law-4267-b(3)(b)(5). The difficulty has been self-created. The applicant purchased the parcel after the Zoning Code was in effect and it is presumed that the applicant had actual or constructive knowledge of the limitations on the use of the parcel under the Zoning Code in effect prior to or at the time of purchase,.and the applicant purchased the property knowing the Accessory Apartment lacked a Certificate of Occupancy. 6. Town Law 4267-b. Grant of the requested relief is the minimum action necessary and adequate to enable the applicant to enjoy the benefit of a 795 square foot Accessory Apartment in an accessory structure. RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing test under New York Town Law 267-B,motion was offered by Member Steinbugler,seconded by Member Acampora,and duly carried,to GRANT the area variance for an Accessory Apartment in an accessory garage with 795 square feet of livable floor area,pursuant to Condition 4 of the Special Exception approval,as granted herein. Any deviation from the survey, site plan and/or architectural drawings cited in this decision, may result in delays and/or a possible denial by the Building Department of a building permit, and may require a new application and public hearing before the Zoning.Board of Appeals. In the event that this'is a special permit.subject to conditions, the approval shall not be deemed effective until such time that the foregoing conditions are met; and failure to comply therewith will render this approval null and void. Any violations of the conditions, occupancy or other requirements described herein, may require a public hearing before the Zoning Board of Appeals to review potential action to revoke the Special Exception Permit granted herein. IMPORTANT TIME LEMTS ON THIS APPROVAL Pursuant to Chapter 280-146(B)of the Code of the Town of Southold any variance granted by the Board of Appeals shall.become null and void where a Certificate of Occupancy has not been procured,and/or a subdivision map has not been filed with the Suffolk County'Clerk,within three(3)years from the date such variance was granted. The Board of Appeals-may,upon written request prior to the date of expiration,grant an extension not to exceed three(3)consecutive one(1)year terms.IT IS THE PROPERTY OWNER'S RESPONSIBILITY TO ENSURE COMPLIANCE WITH THE CODE REQUIRED TIME FRAME DESCRIBED HEREIN.'Failure to comply in a timely manner may result in the denial by the Building Department of a Certificate of Occupancy,nullify the approved variance relief,and require a new variance application with public hearing before the Board of Appeals. Vote of the Board: Ayes:Members Weisman(Chairperson),Acampora,and Steinbugler. (3-0)(Member Lehnert absent, Member Planamento recused) 4eslieKanesWeisman,Chairperson Approved for filing /� /2025 0.01 LOAMY SAND (SM) EL. 5.0' 17s.00, EL. -1.0' • 4.6 \ 1" BORING TEST HOLE `.\ MIXED SAND WITH GRAVEL (5P) � I'I.O' p GRAVEL DRIVE NO GROUND WATER ENCOUNTERED H>: 1 ' <� � SONT TO I-7 FEETACCES BELOW GRADE c q P A RT MET 50RI. Nr--7 TEST HOLE 5HAWN M BARRON M.5. `I GONG PAD M WE�L 124 PLEASURE DRIVE V�G� ,ro,�,( G O RIVERHEAD, NY 1Ia01 5 5� `G 2 5 M gN� TAX MAP:I000 o ?P R S�� GQ 3 B-74' I 1. SECTION:.?O ICJQt % ' BLOCK: 5 Z. F.i= EL. 10.0' 00 vfG,( LOT:45 rn O WO M►N 20' 2 0 1 � A G g �M/N 8 COOL ,I LOT SIZE: 1-7,126.36 50 FT B- TOTAL BUILDING LOT' m ' �` ¢5 �o E�L ��N� �\N z 2 A-5 I 8 COVERAGE: 21'75' A-62' A ALL ADJACENT LOTS ARE AG 1 B-31 3 5=46 I. DEVELOPED WITH NO USE OF WELL WATER t78.36 EL. 7.0' EL. 5.0' WATER SUPPLIED BY MUNICIPALITY FL�OT PLAN LEGENID SCALE I 20' Q HYDRO ACTION AN 600 " = `, . \. Q POLYLOK DISTRIBUTION E0X O / 8' DIAMETER X 5' DEEP LEACHING. PIT _ DAVI VTURNER ARCH CT P.C. SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES 9 �. 0 , APPROVAL OF CONSTRUCTED WORKS FOR \. Qt r11 3M SEVENTH AVENUE,SUITE 1907,NEW YfdRK;N.Y.10123 A SINGLE FAMILY RESIDENCE AND � (212)594 0840: FAX(212)594-1630. 1 Bedroom Accessory Apartment A�KL> WN A�FE��_� --� SEWAGE & LEACF;t NG PLAN. Date 10� � H.S.Ref.NO. R 7477 _ _- 2175 PINE NEZ'CK. ROAD Tin sewage etlsposal and water supply Willies at tide location love been \ --—--—-- -- so UTf'IQLD N. i Inspectedandlor certified by this Department or otfur agencies and found ` =ice-2 , �/ . to be satisfactory FOR TOTAL MAXWUM1 OF 6 BEDROOMS r,,' ^\\�� DATE: 3-25-22 6 4-21 ]ona an Pal, P.E.,CNIEF \ �<. - / PROJECT No: DT Office of Wastewater Management FI Ly r.a tip F.i DRAWING BY:CHK BY: DWG No: A- 1 00.01 CAD FILE No COMPLY WITH ALL CODES OF APPROVED AS NOTED NEW YORK STATE&TOWN CODES DATE;5-A& B.R# So� 5 oZ AS REQUIRED AND CONDITIONS OF # E 55 E SOUMOLDTOWNZM 5-15-25 FE1 1145.OD BY. u SOMOIDTOWN U MNG BOARD NOTIFY BUILDING DEPARTMENT AT SO(tT 0W70WNTAUSM 631-765-1802 8AM TO 4PM FOR THE x N.Y.S.Dw FOLLOWING INSPECTIONS: X SOi1TItO we FOUNDATION-TWO REQUIRED a 5_ FOR POURED CONCRETE �� ��-zg Z5 ROUGH-FRAMING&PLUMBING INSULATION FINAL-CONSTRUCTION MUST BE COMPLETE FOR C-O. ALL CONSTRUCTION SHALL MEET THE Provide windbome debris REQUIREMENTS OF THE CODES OF NEW protection for new exterior YORK STATE. NOT RESPONSIBLE FOR glazing on buildings as per DESIGN OR CONSTRUCTION ERRORS NYS Code. PLUMBER CER77RCA77ON ON LEAD CONTENT BEFORE ELECTRICAL CERTIFICATE OF OCCUPANCY INSPECTION REQUIRED SOLDER USED IN WATER SUPPLY SYSTEM CANNOT EXCEED 2110 OF 1%LEAD. Additional PLUMBING Certification ALL PLUMBING WASTE &WATER LINES NEED May Be Required. TESTING BEFORE COVERING W a GENERAL SYMBOL KEY: Zy w J Y W a� LINDH ACL`;4* ESS0R' A mw0 EXISTING TO REMAIN "' Nai F:o"ATION WALL Z Q ■ 2QQ� I� NyCw FEW WOOD FRAME -r-R� FEW Rv�iBiN6 WALL W PROJECT DATA: ~z y2, -11" "1'-2" PROJECT/ZONI.NG DATA = c x a is xaQwx 6-5' 3-1y2 GAS x 2'-5"xV-q" PH. 2'-O"x2'-q" PH. RANGE TAX MAP# 1000--10-5 48 c o LL z 3 a�zo ZONING DISTRICT R-40 a o S?3 �nI U/,, o o LOT AREA 0.4 ACRES C W p N 0 'AIC) IW axxxm 0 cl r- - - CofO-ALTER EX.ACC.GAR. a-aO DW® BA3gROOM Q � N TO "NON-HABITABLE STUDIO # Z-24398;Ob/OS/1g46 � o i W z° �fV I �. STORAGE SPACE"W/BATH. 3 g m�W G=Q Cl. - ni ATTACHED HE ROOM. BEDROOM 6 GAS W.H. WO-INSROUND POOL d FENCE Z-2444"I;Ob/Iq/Igqb W W=z w _ = i KITCHEN X a w a p 14"1.5 SF I LINEN b� 102 5F o it GAS CofO - 2ND FL ADD.TO Z-24448;Ob/Iq/Igqb a z a W c f 6 NATURAL LIGHT a+ I I I EXIST. I FAMILY DWELLIN6 p g �t� a cV I N BOILER VENTILATION CofO - ROOF MOUNTED w W 1n _ _ SOLAR PANELS ON EXIST. Z-421g8;02/15/2022 Q =W=w o L ACCESSORY GARAGE f r O p a o d� FLOOR 145 S.F. g I 0 (V AREA T GL. CofO- INTERIOR ALT.TO cV x Q I w VENT EXIST.51NGLE FAMILY W/ S.F. R=G. S.F. PROV. L�.�J Q �T9 J VIOLATION FOR AGG.APT. IN Z-4501-f;04/211/2022 AGG.STRUCTURE W/O BLDG.LIGHT � N '+� PERMIT OR SCHD APPROVAL L-m J , i VARIANCE APPROVAL PENDING � 70 RENT 5A S.F. -I.I S.F. .9 Z = uJ - -+--j — Qi a Q I N F HEATER N FEMA FLOOD ZONE X U SM/CO g �t Q I p` z b O 22x61 ROOM @ a 2 xb 1 Qd �q+ SM/GO -ro 5F 2 xb _ RES. � m N = 15'-e 3'-I" 2'-D° cV to O �)p FotK:000NTY-HD - BR--- m _ R-21-1244 _ _� -�- - rRFPROVAL -04'/21/2022- AGG:6AR r 6 BiZ� U 5TAT. L- o Q (� i cV Q� r STORAGE LIVING/DINING F AREA AREA 8o 5F 212 SF x FLOOR PLAN NOTES: A5-BUILT CONDITIONS 4 NO CHANGE TO �VO BUILDING FOOTPRINT (L ;n ry13 - BA5EBOARD RADIATORS THROUGHOUT Q Y r1 LLI m Z Z J N Z W d O Lo I'-q"x4'-5" 4'-O"x4'-5" I'-9"x4'-5" U _ PH. PN. PH. ti I O Q N 0 4'-by2" 00 d. ACCESSORY APARTMENT IN ACCESSORY STRUCTURE — FLOOR PLAN SCALE: va•= r-o" 115 S.F. LIVABLE FLOOR AREA N 'r s_tea. N IQ i p 4 t`s'V Y IA M� tii ui I' TEST ' SILENCE f RESEm W ESH AIR I FIRST ALERT- CARBON MONOXIDE ALARM DO NOT PAINT o44no310 timol wp -daG 6ulpling _- - - _ c_ s c N 0 i-