Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
47499-Z
�o4toF SO(/Tyo`o Town of Southold ,0, * P.O. Box 1179 o� 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 47220 Date: 07/16/2026 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1430 Marratooka Rd Mattituck, NY 11952 Sec/Block/Lot: 123.4-3.3 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 02/01/2022 Pursuant to which Building Permit No. 47499 and dated: 02/25/2022 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof mounted solar on existing single-family dwelling as applied for. The certificate is issued to: Marilyn Winters , Sidney Beebe Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 47499 9/15/2023 PLUMBERS CERTIFICATION: Aut riz Signature ~��SOFFK� TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 47499 Date: 2/25/2022 Permission is hereby granted to: Winters, Marilyn 1430 Maratooka Rd Mattituck, NY 11952 To: Install roof mount solar on existing single family dwelling as applied for. Disconnects must be located on the exterior, labeled and readily accessible as per code. At premises located at: 1430 Marratooka Rd., Mattituck SCTM #473889 Sec/Block/Lot# 123.-1-3.3 Pursuant to application dated 2/1/2022 and approved by the Building Inspector. To expire on 8/27/2023. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-RESIDENTIAL $50.00 Total: $200.00 Building Inspector pF SO!/jyQl 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 sean.devlin(c)town.southold.ny.us Southold,NY 11971-0959 Comm BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Marilyn Winters Address: 1430 Marratooka Rd city:Mattituck st: NY zip: 11952 Building Permit#: 47499 Section: 123 Block: 1 Lot: 3.3 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Element Energy License No: 52689ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 11.2kW Roof Mounted PV Solar Energy System w/ (28) Qcellqpeak 40OW Modules Combiner Panel, AC Disconnect Notes: Solar Inspector Signature: Date: September 15, 2023 S.Devlin-Cent Electrical Compliance Form OF SOUTyo l O l/ �+ ko,l � vl �� klll # TOWN OF S UTHOLD BUILDING DEPT. 765-1802 INSPECTION ( ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [= ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O /1 REMARKS: ce sL( DATE Z7,iNSPECTOR OF SOUTyo� # # TOWN OF SOUTHOLD BUILDING DEPT. couun, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL SpL+y— [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMAR KS: n, Cm -11 00-4P " / 6 i DATE INSPECTOR OF SOUIyO� L-1 ! -- # TOWN OF 1UTH4LiD BUILDING DEPT. courm, 631-765-1802 INSPECTION = [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [/ _] PRE C/O [ ] RENTAL REMARKS: a. DATE INSPECTOR SOUTyO� H7qqq OAl?a rl`A�cvk� TOWN OF SOUTHOLD BUILDING DEPT. co 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: 1ASW 6 i l o DATE INSPECTOR 50UTyO� # # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O a [ ] RENTAL REMARKS: r/>� oa DATE INSPECTOR 50(/l�°� # TOWN OF SOUTHOLD BUILDING DEPT. cou 631-765-1802 ai - INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL SOIL ' [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTO V FIELD INSPECTION REPORT DATE COMMENTS t� FOUNDATION(1ST) -------------------------------- FOUNDATION(2ND) So 0 H ROUGH FRAMING& . PLUMBING y V • l � r INSULATION PER N.Y. STATE ENERGY CODE Q� e 3 ev to �,. D h` 4-d-- -o FINAL. ADDITIONAL COMMENTS • rn �d CY Ib H 'b y TOWN OF SOUTHOLD —BUILDING DEPARTMENT H Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 his://www.southoldtownny. OV Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. � Building Inspector: Applications and forms must be filled out in their entirety.Incomplete FEB 01207.2 applications will not be accepted. Where the Applicant is not the owner,an BUILDING DEPT. Owner's Authorization form(Page 2)shall be completed. TOW:' OF SOUTHOLD Date: L-3 OWNER(S)OF PROPERTY: 3 3.3 Name: s SCTM#1000 Project Address: ._.. Phone#: - ? Email. Mailing Address: / J? a` �i CONTACT PERSON: Name Mailing Address: v �� Phone#: Email: [' � `l'•.!'GyL(. DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name- Mailing Address: Am..._ / Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Struc re ❑Addition ❑Alteration ❑Repair El Demolition Estimated Cost of Project: Other dqo-1-7tit Will the lot be re-graded? ❑Yes TNo Will excess fill be removed from premises? ❑Yes o 1 Lono Sign Document ID:bUPBUFXMHDUXEB4-PSPS'120F(;XUFIJLUM$UC;XN3FiVS50 PROPERTY INFORMATION Existing use of property: Ae y'And Intended use of property: Zone o use district in which premises is situated: Are there any covenants and restrictions with respect to /. this property? ❑Yes I o IF YES, PROVIDE A COPY. Check Box After Reading: The owner/contractor/design professional ls;responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the Issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and In building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210AS of the New York State Penal Law. Application Submitted By(print name): bon N. �Cd ,authorized Agent []Owner Signature of Applicant: Date: STATE OF NEW YORK) COUNTY OF ,ban 1 el� (it, V-6d being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the (Contractor,Agent,Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this I day of... •1�iYl 20C�� Cv U`t11� Notaroublic DEBRA A SEPULVEDA NOTARY PUBLIC,SfATB OF NEW TORIL Registration Nm OISFA12M LSCh. Qualified in n PROP RTY OWNER AUTHORIZATION My Commissionapines " oa re the applicant is not the owner) residing at I ,5p rr im- Cd do hereby authorize _ �. en , to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date -Sto Print Owner's Name 2 I i I � I dUI DING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD TownPFiall Annex - 54375 Main Road - PO Box 1179 o • gu��o� �oe P- Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(a-Dsoutholdtownny.gov - seand(a-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Electrician's Name: License No.: Elec. email: e ,f r, Elec. Phone No: 6' 7 �/ I request an email copy of Certificate of Compliance Elec. Address.: 7ftrf �— JOB SITE INFORMATION (All Information Required) Name: be-- Address: Cross Street: Phone No.: !j/ ?77 ? i3 Bldg.Permit#: email: Tax Map District: 1000 Section: oL3p0. Block: Qi� Lot:,, 0;Vg / BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Hquare Footage: Circle All That Apply: Is job ready for inspection?: ❑ YESdk3'NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES a CIO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 FJ2 F1 H Frame R Pole Work done on Service? Y F1N Additional Information: PAYMENT DUE WITH APPLICATION �SVFI.O(�► ,. ' � � � � ;1 DING_DEPARTMENT- Electrical Inspector a TOWN OF SOUTHOLD wc* DEB Tow all Annex - 54375 Main Road - PO Box 1179 DEVIT� U Southold, 1 k 959a ° �sTelepoe (631) 765- 02 FAX (63 ) 65-9502hn rogerr(a-southoldtownny.gov - sea nd(aDsoutholdtownny gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information.Required) Date: Company Name: Electrician's Name: - C License No:: 5 d7A5 Elec:email Elec. Phone No: 6' 7 '1 request an email copy of Certificate of Compliance Elec. Address.: 7 ? f �-- JOB SITE INFORMATION (All Information Required) Name: 6� Address: Cross Street: Phone No.: �77 ? 93 Bldg.Permit#: H -7 Li email: Tax Map District: 1000 Section: a4 Block: ala6l Lot:l/03�r/ BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): a- fn/Pfr�Ge /Ce- 7�lU -Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YESk]'NO ❑Rough In ❑ Final Do you need a Temp Certificate?: 0 YES,�O Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# FIN ew Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals R 1 FJ2 H Frame D Pole Work done on Service? Y DN Additional Information: PAYMENT DUE WITH APPLICATION �v�c `72 APPROVED AS NOTED OCCUPANCY OR )ATE: B.P.# USE IS UNLAWFUL BY: _ WITHOUT CERTIFICATE ' FY BUILDING DEPART'.` ;T 1802 8AM TO 4 PM OF OCCUPANCY SOWING INSPECTIONS FOUNDATION - TWO REQUIRED FOR POURED CONCRETE ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.O. `G®IV1PL�1'WITH ALL.Co DES ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW NEW YORK STATE & TOWN CODE YORK STATE. NOT RESPONSIBLE FOR �4S REQU ED AND CONDITIONS OF DESIGN OR :CONSTRUCTION ERRORS. SOUTHOLD TOWN ZBA SQUiHOID TOWN PONNING.BOARD SOUTHaD TOWN TRUSTEES N.Y.S.DEC RETAIN STORM WATER RUNOFF PURSUANT TO CHAPTER 236 OF THE TOWN CODE. e Town of Southold January 26th, 2022 Building Department Town Hall Annex ' 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Subject: Roof Mounted Solar Panels:at the Beebe R`esidenc_e:.1430'Mana-tooka Rd Mattituck NY 11952 To Whom It May Concern: I hereby state that it is my professional opinion that the subject plans comply with the 2020 Residential Code of New York State, the 2017 National Electric Code,ASCE 7-16, and NFPA-70. These code requirements include the fact that the roof framing is adequate to support the additional loads from solar panels as well as roof ridge and peak access to first responders. I have evaluated the structural framing of the existing roof with the additional loading to account for the proposed solar panel application. Deflection and stresses of the structural components remain within the allowable for the existing roof for wind pressures from 130 mph, 3 second gust, Exposure B with a ground snow load of 20 pounds per square foot. Mounting locations and methods are as indicated in the submitted plans. From the site inspection and analysis,and as evidenced by previous roof loads withstood, it is my professional opinion that the existing building and roof framing is structurally adequate to support the reactions of the solar panels in addition to the existing code required for live and dead loads.Also the wind analysis concluded that the mounting system as shown on the plans is adequate to resist the calculated uplift pressure.The dead load of the heaviest solar panel assembly in this evaluation is approximately 2.7 pounds per square foot Please contact me if you have any questions or comments about the above. .h ly, F NEW James Deerkos_ 260 Deer Drive �,. Mattituck, NY 11.95 . z 631-774-7355 ��, o. ia_5o AR��S510` A�' r. II SCOPE OF WORK � - G.s.3,,.,.,•, .„., DESIGN 6 DRAFTING BY: TO INSTALL A I 1.2 KW SOLAR PHOTOVOLTAIC(PV)SYSTEM AT THE BEEBE RESIDENCE, ELEMENT ENERGY LLC LOCA T ED AT 1430 MARRATOOKA RD. MATTITUCK, NY 1 1 052. _ ^� © REVIEW BY J.M.NABCEP THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID koMtal,(� IsyGiuo 051 1 1 2-1 29 THROUGH THE EXISTING ELECTRICAL 5ERVICE EQUIPMENT. FF THE PV SYSTEM DOES NOT INCLUDE 5TORAGE BATTERIES. / REVISIONS 5Y5TEM RATING f.:- DE5-;U2 DATE ZV I 1 1.2 kW DC 5TC EQUIPMENT SUMMARY 28 QCELL Q.PEAK DUO BLK ML-G I O+400 WATT PV MODULES I 28 ENPHA5E IQ7PLU5-72-2 US MICRO INVERTERS I IRONKIDGE XK100 MOUNT!NG SYSTEM tbaN RJOey CONTRACTOR SHEET INDEX j PV-I COVER � '.� j ELEMENT ENERGY. LLC, PV-2 51TE PLAN PROJECT LOCATION 7470 SOUND AVE PV-3 ROOF PV LAYOUT v�'TTITUCK, NY 1 1 95c PV-4 STRUCTURAU DETAILS t SECTIONS LICENSE #4388J-H PV-5 3-LINE ELECTRICAL DIAGRAM N PV-G LABELS 0' LICENSE # 52G89-ME GOVERNING CODES I 2017 NATIONAL ELECTRICAL CODE. W 270°4u � 2020 RESIDENTIAL CODE OF NEW YORK STATE. A5CE 7-1 G AND NFPA-70. 2400 120" PROJECT NAME UNDERWRITER5 LABORATORIES NU 5TANDARD5 05HA 29 CFR 1010.2G9 210' 150' L� 10 GENERAL NOTES S O LLn 1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT z _THE 51TE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE 11J O HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK A 2. CO THE SAME. AERIAL VIEW I— 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED ( Oz APPROVALS.PERMITS, CERTIFICATES Of OCCUPANCY,PERFORMED 10. CONTRAC QRTO EFFECT AND MAIIJTAIN INSURANCE, LE_ TOWN COMMENTS AND APPROVAL STAMP W U INSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM CONT' ACTORS LIABILITY,WojWAAiNS COMPFNSATIQN,AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. COMPLETED OPERATION, ETC.•ADEQUATE FOP.THE PURPOSES (�} Q �3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND PRIOR TO Lu .— ALL RULES AND REGULATIONS OF THE RESPONSIBLE OF THIS PROJECT AND FURNISH PROOF OF SAME JURISDICTION. COMMENCING WITH WORK. LLJ I 1. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR �4. IF IN THE COURSE OF CONSTRUCTION A CONDITION fXI5T5 O WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, MAINTAINING SAFETY ON THE JOB 51TE DURING THE (� � THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS ENGINEER.SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND — CONTINUE WITH THE WORK, HE SHALL ASSUME ALL HEALTH ADMINISTRATION.THIS SHALL INCLUDE, BUT ARE NOT FEB 0 1 12022 N 1 RESPONSIBILITY AND UABIUTY THEREFROM LIMITED TO: P ROVIDING FOR ADEQUATE AND PROPER BRACING, 5. ALL STRUCTURAL STEEL SHALL BE A-3G AND SHALL BE SAFETY RAIUNG5 AND SECURE FOOTINGS POP,ALL TEMPORARY =- SCAFFOLDING,STAIRS, ETC.. AS WELL AS PERMANENT BUILLD;Pdr:DEPT. SHEET NAME FABRICATED AND INSTALLED AS PER LATEST A.LS.0 CONSTRUCTION. TCI-1j0 11;;vLU SPECIFICATIONS. 12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE COVER G. ALL ELECTRICAL WORK SHALL IN BOARD OF FIRE DRAWINGS,WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING UNDERWRITERS APPROVED AND IN ACCORDANCE WITH N.E.C. +L � � NYS CODES 4 REGULATIONS CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN CONDITIONS PRIOR TO ORDERING MATERIALS AND FAO COMMENCING WITH WORK. DE J0 CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S COMMENCING CERTIFICATION OF THESE PLANS. 13.CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS DRAWING SCALE 8.THESE DRAWfNG5 AS INSTRUCMENT5 OF SERVICE ARE AND WORK FROM THE 51TE AND DISPOSE OF IN A LEGAL MANNER ON SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE A WEEKLY BASIS OR SOONER IF CONDITIONS WARRANT. r w ii N.T.S. a PROJECT FOR WHICH THEY ARE MADE 15 EXECUTED OR NOT. 14. AT THE COMPLETION OF WORK,THE SITE TO BE CLEARED „t �. DEBRIS AND EXCESS MATERIALS.THE FACIUTY IS TO BE THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR OF ALL DEB ^ EXTENSIONS TO THIS PROJECT LEFT BROOM CLEAN AND WORK IS TO BE COMPLETED TO THE CA, 250 5. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL TOTAL SATfSFACTION OF THE OWNER PRIOR TO RELEASE OF ROB?SS!0���� EXISTING WORK ADJACENT TO HIS WORK, OR DAMAGED AS FINAL PAYMENT. SHEET NUMBER RESULT OF HIS WORK. PV- I TAX MAP: 1 000 123000100003003 f 1 LEGEND CONSTRUCTION NOTES SMAa�A� 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE DESIGN 6 DRAFTING BY: ELEMENT ENERGY U.0 ay Pv -P,W� MANUFACTURERS INSTALLATION INSTRUCTIONS. REVIEW BY�.M,NABCEP cERriFIEe A/C COMBINER DISCONNECT 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. o 051 1 1 2-1 2s NNVER77ERS 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. • p0 ,0.. . Q GND E1EC7RODE �PV MODULE I SSUE P•r/fr/.l'-'.�!����/!�/l�'j•f//.%%/,ir/�,•,;,,,r�I;•lf.%,lfi/�$l'/jlr l iril�/✓j%i�f'��'/r°1.,'l'r'�/",r/�;r/r���!/.//''�r`'�'J,i/,;/�//rff�/��,j�„/�r:r/r/•"1/f/��r,l,r;lf/J�r�l✓/r%.�l,,/t.1!lf�.,li f.r/r/�,r,✓fi'f f;/r/l�/�,/J!!�/;r�r/f�`/ff�r+i+r ff"l�',�r i���fr/�!'°r%r,jf/�ls_,,l�f,ff/°f�`�fr/%j l/✓;f'/��//��✓fi,//,/j//f//.If/'l�//r.'/6'f r/1/`���✓rf,,%r!':/P/�f'�'/lf'✓//r.f//I t�//r''�f•1!r./f P:�r'rl,✓,+r`�r/'j:-r'�/�✓'•'",Jf�.,':j�,r:,r�:'.`%/,r�`fr,is/;"rri�.!J/`i�/.r.f's,`;1�!r•r'>rfr i1'//rflj.J/%/Ir�`1!�/%:/'l/j.r.�r'//�//r,I!/,l't�%'%/�r�r/le�r r�rf,//f`r%!r,�r�j,f'f,rf�J;.i✓r/%°f,sr/r,��,�.r r rlf•✓l 11f'✓/�f�f rr���•'Js/�•/,%.'•%,r✓/'lf�!i.j/•'fJf/•/J:,j!l�l`j.r.,r!r�//.r.%r.,�;r%j,!;r/?/i rl'/"!'`/'iir�/r/l�1/"1rr�1:�//•1,1,'1+i��`/;�f.;r✓/�fj.✓raml i`�!'r/'r�./l.rlr if1/f'/�fj�d/!�'rr'f r'r,, • ' REV--1 510N5 DSfSPTN DATE —RACING RAIL O ATfACHMENTT POINT ) -4—ROOF PIL1 ANGLE SARN 1@IEi r�ZWENT PILM®G VENT ®snr tx;lT CHMNEY GONTRACiOR%/ P07ENnAL SHADING CO<POSIE91iC1f5 ELEMENT ENERGY, LLI CITV.7RB/FMWVE As NECESSARY GOWCOtDl1ICH �� 'ii1IiII ;I !%%fl'fl;j % / f% /ff f%✓' ' f°/f >�;" /'1'.rfi.;�r., ;f/f J`•r/. r �x d /�.f/,/ �' . >%, J 7470 SOUND AVE .i. ,^���/ l,• rf/ f/J � fs /1 /,/. rr /' !'!i,°r'/✓j/fi'`./ir'`1 e%r.' .flr� li°/ r %� j r`. J r. ll'.✓, r ! r r %//f ✓ r li /ri r" f ,r'.r r/' rf /� P/�,�l /r �rr r ./,. fr r��/ �';yri� 1, ;;; f ,._ � f ✓ � / if• / ATTITUCK, NY 1195,� ,/ / /'!'`d/ ° r ✓ ! l r 1 l''° i/6 r ri•._..._.�.� r �f//s'' �/�1•r'f OX LICENSE #43889-tir. j'`�J { . rr ;r/ / , r/ ,, ,1f!/ � %'a !i,/ �; N,/ F' rl,,/f /�i/ll , � lri i Jr ' rlLICENSE # 52689-ME ! r r'` 1 1/ /'r // /r , / r / r%/ r r, r / / / i'-.l 1 r ��r% / •i/,r/ i /f l �! 1la i , /i /, r //1 r. � f.�l rti J {'!. ✓Ji !✓ d /s rJ1/'.f r. /:'. fj/ f�'t'f r ,... /!J !/'" :/f'�'r � if ,,•/R : J`1df'/ rfi/ ' ✓ %%l�r ✓�ir�ii/f,! /!•fff✓�.tf f 'r'" r ✓ r f Jr f j ff%✓ jfnx rrr f,,� r'1✓'r rrs�/ .r r /•��' r /; ✓ r//r�/%�•r 'l/. ! /y�.if' _- — - _ Z. f r}'j;. / .1J f r r' f!'r fr ,; f r llr✓"!i'. ��' :✓: - <,.;/I/� ✓ 1 /f//' ,r%;J ✓ 1j fi r / r ✓ . 1, / , � r r%•X•.i'lrr •f /'i!i JI' r. fl ,r j�f� /i .fr` ': / /rJrl✓",lfi°' r / %� a`/'/ :�'!.•.r r' r./f�'' PROJECT N E t / 1 f /; /rfil s AMA /ff/r✓/ , �. /= f � /� , : f1 ✓��.jli1: :,rJ�fijfl.��jf� / o fj� �J� I�✓/.'r ✓'rr .J � 1%f,!'�/iri /.,...1 f/_/1}sr_ i. , r�>d rill !1'/"j✓ ir. /fr %J !i.' .flerir r 1%jrJ r, r �.1..'%•�i/�` /1' /%/ rr� �rlJr f�r//r `�� //��'. � � , - l' fi il/ rr/f r�i'i'ijirl r f �i✓rl,,//i�f% r J�' r /l�P f/�: 1✓,/ff./ /,° .. ./ r.,/ •/ r%//i / >� / ,, „Jri if/f�%�/f�i��`/f r rr / l,r, /f�,/ f',,.�f��i ✓< /./ � �.lr /' �,lrl/�� i'. O N %' /J��''• .rr r//'.�f r'•' � `r,/'r`lr/ firs/ � �v1��ffJ/�,d° 1 !- :.:! r /'f,// F � r/,l � J�l f l/�f�i',}r/ f1✓ �f //1 f• f�,/���"`r'/- � ll.l lL /C\ / '. ryrd� =�rr�/ > •1,'s=� ,'l� 'fd,✓ram,-,/frf r✓�1J✓/'�r'i'�r`,�` '/r;,�.� U V) !: �/'�:'f r l ,�•'�{'d f //•l.r lj r/',rr''r..!'f./ ✓ �fr �rr,,�/i?� 7 .. %J.:?:��..r%/1/, i���.././1f��J�����ii%d �Jf ff �.. .s.��ii`rr rs�.•.F,r�F f�l�/�I I L � .l�r rl' f✓ r`.:r. I Lu 0--- 4 23_5,� � Q I m Q � }8'-251r it W .211-3" i CD 10 28'-G2" 1 - SHEET NAME 1 51TE PLAN 1 N ' .D e R f"p -- 1 7'-7" ;i' .!r� 'A�r DRAWING SCALE Lu 'NOTE _ W THE ROOF 5ET6ACr/FATHWAY SHALL NOT BEr,5 REQUIRED WHEN THE OPPOSING OR ADJACENT �;o 5HEET NUMBER Rp ROOF SLOPE iS AN ACCESS ROOF IN _ _ - ALSS'.Jr, ��-� ACCORDANCE WITH R324.G.I EXCEPTION OF 2020 NYS FIRE CODE TAX MAP: 1 000 1 23000' OQOQ8- r LEGEND 'NOTE EMSTING UTnm METER THE ROOF 5ETBACK/PATHII`/0.SHALL NOT BE� DESIGN i DRAFTING BY:MM SERVICE PANEL REQUIRED WHEN THE OPP05ING OR ADJACENT �NEW PV SUB-PANES ROOF SLOPE IS AN ACCESS ROOF IN ELEMENT ENERGY LLC A °�"WCT ACCORDANCE WITH R324.G.1 EXCEPTION OF REvie^ BY�.M•NAB PGEr1iFiEt INVERTERS 2020 NY5 FIRE CODE 051 1 1 2-1 29 e GND ELECR ODE QPV MOB REVISIONS -�, J5�2iPIlON _RACKRIG RAIL ;f�i1`, ;.rr"' , DATE REV 0 ATTACHMENT Pi011i - / %' +:/,..,/�;-• C�:�i^��L ___RAFTERS '% .,•'!'/ r`.+fr rr f ,/.-/j✓t`,/ l' r J' /i✓!.r -/r ,r rr'.'.,•/!%�f/ ✓! +` r r'/ O er =i r!r/�'r,j /%r e'/�i,`./J '.e f?er'!/ Oij/./'1%/, !�/r!�r r'.!/ r.•'s':;^t,,'r jiff, �r ,r. / r•rf. F //r rr i/f.i• /• f%J -t tr l' r//,i.;�., f r' �jiF /Jd //r'%fi! %rrf/ /// %'•'%r 'yr.fl:/���/( - - i f—ROOF PITCHANGME s .'r%/ l/, % .' •• r,, r: rr, J!f•.j//�/'/ rj/Jfir- / :. i.',•.r=::.`:'= i.,/, r r f/f �,/•���r��' /✓%�;,Jr i'r: .,r r/!,;.� �!j/i%`�/J i%'!"J�(.J,., .��f!,rrr✓ :V��F x/, I BSUNRIAi ICIER jf ,/rf r" �� /// t"f�i%�;%` i /". i,✓rr`;i f �. fj' fr�!j f/;Jr�1/r�%'/,,.r'.. / %VEWT r'��: '!"' f ' f�'/'•". r/� rrl r /J t✓ r r !fl1A1BDIG VDIT %'�'// r•r /'r r r �,t %/i / J r ® J'/ /.rZ / ! r r r ,. rr,i r l%1/'/ /✓'r r f f/// 'r'j y SKYLIGHT >, r !/d i/dJ, r /J °f%r / e%/f:!.j r {l r/rrJ/i/ / /, � ..rrr�! '� /�`: s /mil erJ y'r✓j,��=%�i I ®CHW!{f7 rj f'•/r�/%' �//% f�/ '` J r r / �r / j/f jf/ /' /J•�/r!/r r / t 1ff / /rl/ /�•!✓::, - _ _ ,.f/ / r / f.r -./ ir. +: ! t ✓r /, rf/ /. / /�i // I r r! rrr COYP097E SHINGLE r. 'i :/f'•'• / rl/i J r r Jr r r j /•"/ >;r'' r✓✓/f� /f%'r /.y; CR GOOD COWTitOli /.� f / .t 'rr' :,✓ ll�/ J i 'r,// Jr ,�'/rr'. /.`i`•%' CONTRACT . �rl,' /r ,.// .jrr ! �!, "!✓ '1 J >r<• J•//r /a j:<', �POiBr11Al:91A68iG ISSUES ,�:i• r /r /,:r l.fr;1.l,- i t/r.,i:r r/:F:;r:,i ,':, /� �i, td..•r %� rr r,r;y •,r: 7R�l/ALiWW-ASHECf'�ARY M /% �. r//•'' 6,�'�:%�:i,->rl` r;`!!:r,J1:,� t I- /,/r>/..J1rr�� r r,%'fjrj.� rr•/?� ,r j: 1, /'' •r,/rr!"% :•j/ ,/r : % /r / //� /- l/r / rr ti/ Y ,r. / -r ps.' r r7 //f. ��/r,v r`-r r ;. Jrr! ///lr' ,♦ rr//i/ ELEMENT ENERGY, LLC. 7470 SO } r.� 'f ;�l/// r ' / /.!y / // �! •, , ,r'. /r ! °�/.,/j j'%�1/�i! /, f� UND AVE Jr, 'f//i! ✓; tf'✓l /�/j!''r' r r r / jrr t �JJ 1: /f%%j I rJ✓!/,'/ r MATTITUCK, NY 1 135i ,.',, ;; r/Irrl r ✓,r-r .r /gyp,.J F' t j !' r , s..r! /.r +. / r r r /J / j/ %��rJr�{r '�� • /; f/ r f, > / 'r"' /�i .r/i iJ I�r J J� J`�,;tr LICENSE #43889-11 1 / �/ � ,✓ !�rr /f// /"./ EJ r r, ;r!/ l /fr i r✓r,.r l; r ! , ,r1J ".% LICFNS.. # 52689-ME � f✓ f //i' r�rf' r r / lr//fi /r rr,r�1 �! i%/ r � ir�... /ixf �l /• /r�'jf/rrr'i..;`,.r r�/ r, // l /•.!�/r/ /•y rr j -/�� t-r-..'i`.//,: :r%>:.. , '/r'/I / Y /fT//!j J/ r/, , f r r r r •r rJl� ' :,'-;Y;.rtJ/; flri /. /rr1�� / r - Jf% /✓ j/ /l. 1 i_�u , l L? %' :'J'r 0.,/fisf! / r ✓' / r .'' ! i i r !r rr''J�rf J.f� "'I✓ Il /�,f r f�f�/�// /r' ! J / r // �''r 'd'r,✓if:l,'!r ��/ PROJECT NAME rf %1'ri'^, Jf/ / %i rl,/1 rrllrrl s/l /,rrr/frr fl, i/.rr✓s.J�l'� i! , 'I fr/ J> f r� i 1. //e r t ✓,.''-. /J r% irJ/ �i/ %rr / Fl.ffi,. � /�� z LLJ ,rrt'/%�Y%/+��/�'/, r ./ :�''//`{f�r/-y rfrrfj�r J,r' it e%%r�/rf'ri'rr,,� � /`f•rf:: - �V ARRAY#2 U G MODULES z 3u 20 PITcy Lu — 2--�r� ! 248'AZIM�H Q W cz 2'- 1 I N. w oL ARRAY#I W ~ 22 MODULES I 248'ADMUNn a a1 �l 41 SHEET NAME CONSTRUCTION 5UMMARY- p (28)QCELL Q.PEAK DUO 13LK ML-G 1 O+400 WATT PV MODULES I\OOF DETAI (DIMENSIONS: 74"X 41.I"X 1.3") / /;.�.:r)E (25)ENPHASE IQ7PLU5-72-2-U5 MICRO INVERTERS (54)ATTACHMENT POINTS @ 72"O.C. MAX. LIEF_ (194.1) LF IRONRIDGE XR 100 MOUNTING SYSTEM. y-: - /.: ROOF TYPE =ASPHALT SHINGLE(SINGLE LAYER) -• DRAWING SCALE CON5TRUCTION NOTES m ! a �: �811 — 1 1_011 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. O co �? 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH A" MINIMUM NEMA 3R RATING. RO 10 V SHEET NUMBER 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE ��—� FIELD vERJFiCATION. TAX MAP: 1 000 1230001 00'03003 t • ' t 1 t LOAD CALCULATION ARRAY!!I ARRAY z2 ITEM DESCRIPTION ARRAY#1+I:2 RB R,d a BearJBoard 4"X I DESIGN t DRAFTING BY: MODULE -�" LVL ELEMENT ENERGY LLC WEIGHT(Lbs) 48.5 48.5 (R) Rafters 2'-K.. 12,n.,n� ta,I a—u.-. x OF MODULES 22 6 (D) Deckin REVIEWBYJ,M,NAB CEP CERTIFIEC .11�•"Pt`r'��'OCti? 051 I I z-i z9 Q CeilingJoist 2"X 10"D, FIR aCD.I O_C. TOTAL MODULE WEIGHT"5) 1067,0 291.0 ' (P) Pitch 2 Qo l TOTAL LENGTH OF RAIL(Ft) 1525 REV1510N5 41.6 (K) Knee Wall - f7 ;tR, i y i� 1a t c Dn ? DATE REV H n n f"R)RAIL WEIGHT PER FOOT(Lis) 0,68 0.68 TOTAL RAIL%LIGHT(Lb-,) 103.7 28-3 #OF 5TRANDOFF5 42 12 (R) 1 WEIGHT PER STRANDOFF(Lb,-) 2 2 (D) TOTAL STANDOFF WEIGHT(Lbs) 84 24 TOTAL ARRAY WEIGHT abs) 1254.7 343.3 PORIT LOAD(Lbs) 29.9 28.6 TOTAL ARRAY AREA(Sq Ft) 471.0 128.5 CONTRACTOR ARRAY DEAD LOAD(Lbs/Sq FL) ._ 2.7 -- 2.7 % GROUND ww r WIND SUBJECTODAMAGEFROM i ELEMENT ENERGY, LLC. ? SEISMIC - ICE ER AM MEAN _ - 7470 SOUND AVE SNOW Topogrsp}dc SPedil Wind�e DESIGNFzo� DE96N ICE FLDDD FREEZING ANNUAL . LOAD* peed et k =d debitsCANIOt1Tr weatherW Rae Ternate` ape eErimaEa'r HAZARD0 tluDEx' 7A�W (tJ i4�ATTiTUCK, NY 1 195 regfcn' zone' depyP i LICENSE #43889-f-i LiCEN5E # 52G89-ME -- _. - I 20 140 NO NO NO B SEiJERE 3 FT HF�W 15"F YES 599 51-F l E' MANUAL J DESIGN CRITERUP t , Elwation Latitude Winter summer Attitude Indoor D�En heating heating cooling cwrectionfaanr dam° tenqmwature��8 temperature r 106 FT __ _ . ditererme _ PROJEC'a NAME 41'N 15'F WF 1.00 70'F 75"F 55'F Coofng temperaturedi(ferenot ti heatodtying w�delr raw humidity Warier Summermi — 0) cairns eoot►erg wettwdbQ t 11'F __ 15 MPH 7.5 MPH 72'F MEDIUM(M) 40% 32 GR @50%RH 1JJ O For SI:1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 m/s, a. Where weathering requires a higher strength concrete or grade of mason than necessary to satisfy ' ROOF FRAMING DETAIL n 9 masonry ry trsfy the 5irtrctuiat requGemenLs oflh>s'code,the irostJine depth strength: Q O required for weathering shall govern.The weathering column shall be filled in with the weather! -index; negligible moderate or"5euere"for concrete as determined --- - 0 z from F ure R301_ 4 The grade of masonry units shall be determined from ASTM C34 C55 C62 C73 C90,C129 C145,C216 or C652. rg 2( 1 LL b. Where., lmere Uie frost line depth regwres deeper footings than ihdicated in Figure R403:1(1) the host line'dePth streiegttt requrretJ:forweathering stiatl govern.Thejunsdiction. shall.ftlf m ttte Trost line.depth columh with the mutrmurrl depth of footing below fnish grade. C. The jurisdiction shall fill in this part of the table to indicate the need,for protection depending on w'ttether there has been a history;of iocal subterranean termite dama e. MODULE MOUNTING CLA-I�tF d. Thejunsdktion shall fill in airs part of the table with the wind speeq y-qm the basic wirrd'speed map[Figure 8301:2(5)A].Wind exposure.category shall be detenhiried on a site-specific basis in accordance with Section R301,2-1.4. SOLAR NODULE - (� Q e. The outdoordesiWr dry'-bulb temperature shall be selected from the columns of 97112-percent values for winter from Appendix D of the Plumbing Code of New York (LJ Sta4e.'Dewawnsfrorit ltie Appendor D temperatures shall be permitted to reflect local diinates or local weatherexperience as determined by the binding official[Also STFdNLE55 STEEL 3/8' - W see Flgure,R3D1.2{t).] 9JLT-AND NUT f. The jurisdiction shall fill in this part of the table with the seismic design category detemmined from Section R301.2.21. ' Q g. To establish flood hazard areas,each commun ty,regulated under Title 19,Part 1203:of the.Offrc®I Compilation of Codes.Rules and Regulations of the State of New York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map,shall include,at a minimum,special flood hazard areas as identified by the r federal Emer9Ency Management Agencyin the Food Insurance Study for the community,as amended or revised with: ut7FID E ALUMINUM fthiL I.The'accompanyirg Flood Insurance)late Map(FIRM),it T ='' Flood Boundary and Floodway Map(FBFM).and ALUMINUM"L"BRACKI nil.Related supporting data along with any revisions thereto. The adopted food hazard map and supporting data are hereby adopted by reference and declared to be part of this section. 3+I UMINUM FLASHING h. In accordance with Sections R905.1.2,R905.4.3.1,R905.5.3.1,R905.6.3.1,R905.7,3.1 and R905.8.3.1,wherethete has-been a history of local damage from the SHEET NAME eeects;of ice damriing,the jurisdiction shall fill in this part of the table with"YES."Otherwise;the jurisdiction shall f"I in this part of the table with"NO." i. The juOsdiclion,shatl RI in-this parto).thedable with the 100-year return-period'airffeezing index(BF-days)from Fiounb R403.3(2)or from the 100-year`(99,peroent) value:on:the National Climatic Data Center data table AirFfeezing index USA Method(Base 32 F.)." j. Thejurisdiction s40 fill in this paitofthe table with"the mean`ahitual temperature firim the National Climatic Data Genter,data table"Air Freezing Index-USA Method ASPHALT SHINGLE TRU CTU I\Tl (Base 32 1'.OQP' ! r N E w yo S L .� I �Y1r IL In accordance tivit_ti Secpon;R30121.5,where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects,the 1 f� 1! PH 5 O . )ursdicUon shall fill in thls',pait of the.table with'YES."Otherwise,•the jurisdiction shall indicate"NO"in this part of the table. p YH'�tid 1. In api;pr. ncewith Frgum R901 2(5)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this part of the table with I ET "YES"and identify any speck requirements.Otherwise,the jurisdiction shall indicate"NO"in this part of the table. , � `"0= DRAWINGSCALE LLt M. In accordance with Section R301.2:1.2 the jurisdiction shalt indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the i� Z AS NOTED table. �. n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1a or 1b from ACCA Manual J or established criteria determined by the ti; jurisdiction. G � Ati o. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(6)for sites at elevations up to 1,000 feet Sites at �O�SS10'1• elevations above 1,000 feet shall have their ground snow load increased from the mapped value by 2 psf for every 100 feet above 1,000 feet (') See Figure R301.2(4)B. ' SHEE `T/NUMBER TAX MAP: 1 000 123000100003003 MOUNTING DETAIL i ` I P V _4 1 50LAP ARRAY ON MAIN HOU5E 1 !.2 kW (28)OCELL Q.PEAK DUO LAL-C-i O+ 400 WATT PV MODULES DESIGN 6 DRAFTING BY: (1)STRING OF(9)MICRO-INVERTERS 8(2)5TRING5 OF(8)MICP.O-IN\'ERTEP.5 ELEMENT ENERGY (3)STRINGS TOTAL LLC REVIEW BYJ.M,NABCEP CERTIFIEC -- 051 i I2-129 — � TO llTILJ1Y GRID _ STRING # _ III I ODATE REV 1 BI-DIRECTIONAL UTILITY METER � 1-PHA5E-240 V STRING4�—j L1 2 r y — - 1 D CONTRACTOR 4dPh„�BRANCFS' v�I„F N�nl�k, ��A 1 1 CIRCUIT CABLE TYPICAL ffN'^A FLJ. 71 - G A ELEMENT ENERGY; LLC. ; �''` " ; �; AC DISCONNECT 1 . a 7470 SOUND AVE =- 3' _1 mATTITUCK, NY 1 195% ° LICENSE#43889-11 a LICENSE# 52G89-ME i - E N N } — MAIN SERVICE PANEL PROJECT NAME - AC COMBINER BOX 1 - i 1 z ^ N Q r - 1 EXISTING GROUNDING ELECTRODE SYSTEM W, WIRE f-CONDUIT SCHEDULE L CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX,CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP f ESTIMATED Voltage Drop(% W I.D.# ORIGIN DESTINATION SIZE PER POLE QUANTITY DEBATE INSULATION SIZE QUANTITY INSULATION (GYPS TYPE SIZE TEMP DEBATE - - 310-15(5)(3) --- t INVERTERS COMBINER PANEL AWG#I O L G 0.5 U5E-2/PV Wire AWG#8 1 BARE CU FREE AIR I"- SSQC 0.84 W � —DISTANCE _r OR EMT- I I O O 8% 3 COMBINER PANEL AG DI5CONNECT AWG#8 I 3 I THWN-2 A\vG#8 D THWN-2 CU PVC 4SQC 0.95 { G AC DISCONNECT MAIN PANEL AFYG#6 t 3 - 25� O.G% I THWN-2 AWG#8 j' y THWN-2 CU PVC g59C Dan 10 FT O.G% ELECTRICAL NOTES CALCULATIONS FOR CURRENT CARRYING CONDUCTORS SHEET NAME I.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATIO!,L 2,)ALL CONDUCTORS 511AI-L BE COPPER, RATED FOR COO V AND 90PC WET ENVIRONMENT. #I PV Source Circuit Wire Ampacity Calculation GOJJFiGURATIOEL.__ 3.)WIRING,COFIDUIT.AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIP.ECTLY ItlEC 690b(R)(1)) I! ) .,,+}L t:rn,gg) (I_SG) 13.61 A a A WC-1#10.a tls�.;-�t +��nif fc aEe i:,i.�.A Modules per String q MAX. 3-LINE D I A. TO.AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RICGE,HIP, OP.VALLEY. a.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENJT SHALL 2G.88 A> 13.61 A.therefore DC wire size js valid, Modules ea Inverter- 7,1 , COMPLY WITH NEC 110.26. #2 Inverter Output Wire Ampacity Calculation Number of Inverters 28 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS„CONTRACTOR SHALL Inverter Max Amperage output'(1.25)=42.35 A Record low tcm'; 1 CPC YQ. FURNISH ALL NECESSARY OUTLETS,SUPPORTS. FITTINGS AND ACE5SORIE5 TO FULFILL t x m 1 arlt} ;Teml=C crate! C r Jvi P!iI r rratCj 5L.25 Voc Tamp-Coefficient 5 nEt h� fir APPLICABLE CODES AND STANDARDS, i2 '5 A 2,v5 Ai Lrtire f A.1:s r, .5 ka11: G.)WHERE SI2ES OF JUNCTION!BOXES. RACEWAYS.AND CONDUITS ARE NOT SPECIFIED, DC SYSTEM SPECIFICATIONS 1 DRAWING SCALE a COmbinerd Inverter Output Wire Ampac+ty-galculati?ia` EFiLGi1LhT! J 1, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY, Inverter Mar.Amperage output'(1.25)= 42.v5 A O eratm'Current. ?,t3 A =4#ofs-nn:;) 7.)ALL WIRE TER J:INATIOi 15 SHALL BE APFROPRIA ELY LABELED AND READILY VISIBLE. — L!J N T 5. AWG#6,am Nat (Temp Derate)'(Condwt Fill Derate 7 1,25 A O eratm ,VaLEabe 37 13 4- =(r mcduhs In serte5)`(i'mi=) S(1 �_:z: `� 8.)MODULE GROUNDING CUP TO BE INSTALLED BET41'EEIJ MODULE FRAME AND MODULE 71.25 A> 42.35 A.therefore AC wire 5re 15 Val'd.) Max.SySterrl,Volta _ 49.6 V (#mcaulc^'In SUPPORT RAIL. PER THE GROUNIDING CLIP MANUFACTURER'S INSTRUCTION. e.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINIUOU5 COPPER G.E,C.VIA WEED LUG Short Circuit Current 13,9 A =;(a,;of star ;'Ili-c) (.I.25)4cr Art..69 {C,1�- -(J k {� OR IL5C0 GBL-4DBT LAY-UJ LUG. AC SYSTEM SPECIFICATIONS /Y: �Q� SHEET NUMBER 10.)THE POLARITY OF THE GROUNDED CONDUCTOR5 15(po5,twe/regatr✓e) Max AC Cut ut Current 2 3.5 A OR i O.)THE DC SIDE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC 690.35, Onera4'n` 'AC--Volta- 24O'�r PV-5 `/—5 TAX MAF: 1 000 123000 1 0 O03003 V SERVICE METER O O ® DESIGN d DRAFTING BY: INSTALLATION NOTE ELEMENT ENERGY LLC REVIEW BY J.M,NABCEP CwfLTIFII SOLAR PV SYSTEM PH-OTOVOLTAIC • • • 051 1 1 2_1 29 SOLAR BREAKER ® © . EQUIPPED WITH __ ( I ) ALL LABEL SHALL BE INSTALLED I N RAPID SHUTDOWN - ACCORDANCE WITH THE 2017 NEC �V15ION5 Q REQUIREMENTS. -TE R,, (2) ALL LOCATIONS ARE AF'F'ROXIMATE AND ✓n''" SOLAR AC LOAD CENTER- OUTSIDE = DONOTRaO(ATETHS SHORT r�'IRCUIT CURRENT A REQUIRE FIELD VERIFICATION. - I OY9tCURRERT DEVICE ° - - -- -- (3) LABELS, WARNING(S) AND MARKING TURNmmSHUID09wSwffCHTO I ® SHALL BE IN ACCORDANCE WITH NEC TTEwrPOS mTOSlwDOWN I PVSYSTEMANDfEDUM ---- - 1 1 0.2 1 (B). 1 sfloacTLazArLDTrrTTEax�aY AC DISCONNECT !� �AUTmt," (4) THE MATERIAL USED FOR MARKING PoP�IIi T071ESMCC64ED SIlIAllED I rwa nc rounuwc�cz e>rrn, SOLAR AC LOAD CENTER- INSIDE 0 r MUST BE WEATHER RESISTANT, IN® P -: _"I ' COMPLIANCE WITH NEC 1 10.21 (5)(3). CONTRACTOR Pam. 'fib (5) THE PV SYSTEM CIRCUIT CONDUCTORS ELEMENT ENERGY, tl . TMSB°UFyBlTF�9'MATLPLE DUAL POWER SUPPLY -.! SHALL BE LABELED INSTALLED IN SOUR=TMRAT= FALL � 7470 SOUND AVE w_ r :oca1 SOURCEE:urnmrGRID COMPLIANCE WITH NEC 690.31 . MATTITUCK. NY 1 195 ANDwso1AR LICENSE #4388E-H DEacr~slLAuuorT>� F,�TTRIcsYSTEn CONDUIT- INSIDE BUILDING YOFINWAR LICENSE # 52G(59-ME 1 1 y - THIS SERVICE METER I f IS A SO SERVED BY A PZOJEGT NAME j _ [1FCTRIC SMOCK FlA71tiRD � PHDTOVOLTATC SYSTEM I PHOTOVOLTAIC SYSTEM � 7EFWK4LS ON TFE UNE AM COMBINER PANEL Q i 10ADJ CE OPEN� ID DO NOT AD_O LOADS Q CONDUIT- OUTSIDE BUILDING i N O ® W � m - r W O DUAL POWER SUPPLY C) O Z ISOUS IO UTLITY GRAND PV SOLAR ELECTRIC SYSTEM' ® W MAIN SERVICE PANEL- OUTSIDE _ O �CAUTION S01AR CIRCUIT W �/ U Q O OCAUT ION _� ® Lu SOlARI3FCIPoCmwmcmwzr®j Lu O Q . • • m MAIN SERVICE PANEL- INSIDE I PE POWER SOURCE I OUTPUT CONNECTION SHEET NaME DO NOT RELOCATE THIS O O OVERCURRENT DEVICE LABELS AC DISCONNECT/BREAKER , V, DE. O A O ® ® `�i .`i •n� r. DRAWING SCALE U7 N.T.S. SHEET NUMBER kJ ssi = Pv-6 TAX MAP: 1 000 1 23000 1 000.3003 Data Sheet Enphase Microinverters Region:AMERICAS The high-powered smart grid-ready Enphase Enphase IQ 7 Micro'"" and Enphase IQ 7+ Micro"' IQ 7 and IQ 7+ dramatically simplify the installation process while �d �t achieving the highest system efficiency. Microinverters Part of the Enphase IQ System,the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy, Enphase IQ BatteryTM, and the Enphase Enlighten TM monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install r_ Lightweight and simple • Faster installation with improved,lighter two-wire cabling • Built-in rapid shutdown compliant(NEC 2014&2017) Productive and Reliable • Optimized for high powered 60-cell and 72-cell*modules • More than a million hours of testing • Class II double-insulated enclosure • UL listed 0 Smart Grid Ready • Complies with advanced grid support,voltage and tollfrequency ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) U� *The IQ 7+Micro is required to support 72-cell modules. To learn more about Enphase offerings,visit enphase.com ,e, E N P H AS E. Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA(DC) IQ7-60-2-US/IQ7-60-B-US IQ7PLUS-72-2-US/IQ7PLUS-72-B-US Commonly used module pairings' 235 W-350 W+ _235 W-440 W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48-V 60 V Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range 16 V-48 V 16 V-60 V Min/Max start voltage 22 V/48 V 22 V/60 V Max DC short circuit current(module Isc) 15 A 15 A Overvoltage class DC port II II DC port backfeed current _ 0 A 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal(L L)voltage/range2 240 V/ 208 V! 240 V! 208 V/ 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(L-L)branch circuit3 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current -0 A 0 A Power factor setting 1.0 1.0 Power factor(adjustable) 0.7 leading...0.7 lagging 0.7 leading...0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 97.6% 97.6% 97.5% 97.3% CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperature range -400C to+65°C Relative humidity range 4%to 100%(condensing) Connector type(I07-60-2-US&I07PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC_-5_adapter) Connectortype(IQ7-60-B-US&IQ7PLUS-72-B-US) Friends PV2(MC4 intermateable). Adaptors for modules with MC4 or UTX connectors: PV2 to MC4:order ECA-S20-S22 PV2 to UTX:order ECA-S20-S25 Dimensions(WXHXD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 Ibs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree- PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of,an Enphase IQ Envoy. Di sconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.Seethe compatibility calculator at htt s� .//enphase.com/en-us/support/module-compatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Referto local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com v EN PHAS E. ©2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. 2018-05-24 powered by �I !' WIMY iDU6 ! 1 • • - a TOPBRAND PV ,i 0 S EUROPE / ', / Warranty y aoa� Yield��j Gl CELLS BREAKING THE 20%EFFICIENCY BARRIER AQ.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9%. THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY leTI_ Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry:The new"Quality Controlled PV"of v� the independent certification institute TOV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields,whatever the weather with excellent C_J low-light and temperature behavior. i ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology,Anti PID ` Technology',Hot-Spot Protect and Traceable Quality Tra.QTMt. EXTREME WEATHER RATING High-tech aluminum alloy frame,certified for high snow(5400 Pa)and wind loads(4000 Pa). (2 A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year 1 linear performance warranty2. �APT test conditions according to IEC/TS 62804-1:2015,method A(-1500 V,96 h) 1 See data sheet on rear for further information. THE IDEAL SOLUTION FOR: 61) Rooftop arrays residential buildings Engineered in Germany OCELLS MECHANICAL SPECIFICATION Format 74.0 in x 41.1in x 1.26 in(including frame) (1879 mm x 1045 mm x 32 mm) 74.0•(1M^^^) 428•(SOBBmm) 16.6.1386.Smm) Weight 48.5lbs(22.Okg) Front Cover 0.13 in(3.2mm)thermally pre-stressed glass with =4er(urns) anti-reflection technology 4,omeP�e.oaa•(asm) Back Cover Composite film 3er a-) Frame Black anodized aluminum 4u•paa5�) Cell 6 x 22 monocrystalline Q.ANTUM solar half cells C3 Junction Box 2.09-3.98 in x 1.26-2.36in x 0.59-0.71in (53-101mm x 32-60mm x 15-18mm),IP67,with bypass diodes _E1 149T(N&) ) Cable 4mm2 Solar cable;(+)>_49.2in(1250mm),(-)>_49.2in(1250mm) 4,Mw gst-(MTNL A) 1 Connector Staubli MC4;IP68 1 +V F-L4W(32-) nETAILA 0.83•(lamm) I I I'-� o.se(24.5,,.")I --- 0ZT(a6..") ELECTRICAL CHARACTERISTICS POWER CLASS 385 390 395 400 405 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STCL(POWER TOLERANCE+5 W/-0 W) Power atMPP1 PMPP [W] 385 390 395 400 405 E Short Circuit Current' Isc [A] 11.04 11.07 11.10 11.14 11.17 E Open Circuit Voltage' Vcc IV] 45.19 45.23 45.27 45.30 45.34 .E Current at MPP IMPP [A] 10.59 10.65 10.71 10.77 10.83 Voltage at MPP VMPP IV] 36.36 36.62 36.88 37.13 37.39 Efficiency' q [%] >_19.6 >_19.9 >_20.1 >_20.4 >_20.6 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT2 Power at MPP PMPP [W] 288.8 292.6 296.3 300.1 303.8 E Short Circuit Current Ise [A] 8.90 8.92 8.95 8.97 9.00 E Open Circuit Voltage Vcc IV] 42.62 42.65 42.69 42.72 42.76 'c 2 Current at MPP IMPP [A] 8.35 8.41 8.46 8.51 8.57 Voltage at MPP VMPP IV] 34.59 34.81 35.03 35.25 35.46 'Measurement tolerances PMPP±3%;Isc;V.±5%at STC:1000 W/m2,25±2°C,AM 1.5 according to IEC 60904-3.280o W/m2•NMOT,spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE �....Lap peals M"a T____ ' At least 98%of nominal power during i , first year.Thereafter max.0.5% z degradation peryear.At least 93.5% of nominal power up to 10 years.At LL z least 86%of nominal power up to W So 25 years. ,_____�_____J Z �z 5 . All date within measurement tolerane- i m 0 - --------------------------- i i m w as.Full warranties in accordance with °0 , o the warranty terms of the Q CELLS mo wo soo eao laaa o IRRADIANCE R/m'] o m sales organisation of your respective o C1 4 e ]A m Country. p.�.4m,nmp� m„remwram p, YEARS Typical module performance under low irradiance conditions in o comparison to STC conditions(25'C,1000 W/m2) ,mac m m TEMPERATURE COEFFICIENTS o Temperature Coefficient of Isc a [%/K] +0.04 Temperature Coefficient of Vcc R [%/K] -0.27 Temperature Coefficient of PMPP y [%/K] -0.34 Nominal Module Operating Temperature NMOT ["F] 109±5.4(43±3°C) m 0 PROPERTIES FOR SYSTEM DESIGN w Maximum System Voltage Vsrs IV] 1000(IEC)/1000(UL) PV module classification Class 11 o 4] Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 61730 TYPE 2 m Max.Design Load,Push/PulI3 [Ibs/ft2] 75(3600 Pa)/55(2660 Pa) Permitted Module Temperature -40°Fupto+185"F o Max.Test Load,Push/PuIl3 [Ibs/ft2] 113(5400 Pa)/84(4000 Pa) on Continuous Duty (-40'C up to+85,q o mrn 3See Installation Manual U V QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION m UL61734 CE'led P iant, f�/A alVl M1V%I Ib C� _O m Quality 61 Controlled C 1730 Rhetnlend, GUS O(--OlIEC 61215:2016,IEC 6173Q20U.S.Patent No.9.893.215(solarcellsnlvN,aw,4 Horizontal 76.4in 43.3 in 48.Oin 1656lbs 24 24 32 9QCPV Certification ongoing. Cpackaging 1940mm 1100mm 1220mm 751kg pallets pallets modules 9 mniea - ip nnapnr UL BUM n y Note:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwha O CELLS America Inc. 400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618,USA I TEL+1 949 748 59 961 EMAIL inquiry@us.q-cells.com I WEB www.q-cells.us