Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
52181-Z
�o�aoF s°oTyo`o Town of Southold * * P.O. Bog 1179 % At 53095 Main Rd U11% Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 47233 Date: 07/21/2026 THIS CERTIFIES that the building Swimming Pool with Fence-In Ground Location of Property: 2445 Private Rd #18 Mattituck, NY 11952 Sec/Block/Lot: 121.-4-7.1 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 08/12/2025 Pursuant to which Building Permit No. 52181 and dated: 08/13/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Accessory in-ground swimming pool fenced to code as applied for per ZBA#7931 dated 8/15/2024. The certificate is issued to: Paul Seck ,Florencia Azpiroz Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 114161 5/26/2026 PLUMBERS CERTIFICATION: uth ySature ho�aOf SO�jyo`o TOWN OF SOUTHOLD BUILDING DEPARTMENT • TOWN CLERK'S OFFICE COOK", SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52181 Date: 08/13/2025 Permission is hereby granted to: Paul Seck 430 St'. Mark Ave Brooklyn, NY 11238 To: construct accessory in-ground swimming pool as applied for per ZBA approval. Premises Located at: 2445 Private Rd #18, Mattituck, NY 11952 SCTM# 121.4-7.1 Pursuant to application dated 08/12/2025 and approved by the Building Inspector. To expire on 08/13/2027. Contractors: Required Inspections: Fees: SWIMMING POOLS-IN-GROUND WITH FENCE ENCLOSURE $300.00 CO Swimming Pool $100.00 Total S400.00 Building Inspector -F NASSAU ELECTRICAL SUIIOLK INSPECTORS 159 Route 25A, Building 1 Suite B Miller Place, NY 11764 Telephone:631 495 8136 - Fax:631 509 4538 • E-Mail: Info@SuffolkBEI.com CERTIFICATE OF ELECTRICAL COMPLIANCE Applicant: Big Sky Electric Corp Certificate No.: 114161 Rough In Inspection Date: Nov 11,2025 Final Inspection Date: May 26,2026 Application No.: Building Permit No.: 52181 County Tax Map No.: This Certificate of Electrical Compliance is limited to the inspection and compliance of electrical equipment and/or work described below,installed on behalf of the applicant named above,located at the premise of and not after the final inspection date above: Owner: Paul Seck Site Location: 2445 Laurel Lake Road,Mattituck,NY 11952 Owner's Address(if different): 12 Residential ❑Indoor ❑Basement ❑Service ❑Shed ❑Commercial 19 Outdoor ❑First Floor 0 Pool ❑Hottub ❑New ❑Renovation ❑Second Floor ❑Attic ❑Garage ❑Addition ❑Survey ❑PV Solar ❑Generator ❑Conversion .........-------------------------------- ❑Signs ❑Battery Storage ❑Safety Inspection Other: INVENTORY Single Phase Heat Duplex Recpt 0 Ceiling Fixture Dual Func Breaker Three Phase Hot Water GFCI Recpt 0 Wall Fixture Smoke Main Panel AC Cond Single Recpt 0 Recessed Fixture CO Detect Sub Panel AC Blower Range Recpt LED Lighting Smoke CO Combo Transformer Appliance Ckt Dryer Recpt Emergency Time Clock Disconnect 0 Switches 0 Twist Lock Exit Fixtures 0 Pumps GFCI Breaker 0 Heat Pump 0 Electric Heat 0 Pool Luminaire ® Exhaust Fan 0 Other Equipment:Bonding completed.Photos are in file manager.Bonding inspection 11/11/2025auto pool cover The electrical work and/or equipment described above were inspected and was found to be in compliance with local, state and national electrical code requirements and this office. Applicant: Big Sky Electric Corp License No.: ME-5164 Date Printed: May 26,2026 Inspected By:Joe Coppola Signature: S _ OF soblH°� # # TOWN OF SOUTHOLD BUILDING DEPT. co 631-765-1802 INSPECTIONI1 [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULAR ON/CAULKING [ " ] FRAMING/STRAPPING IV FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ "] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR 1 N. J. MAZZAFERRO, P.E. PO Box 57, Greenport,N.Y. 11944 Phone - 516-457-5596 Consulting Engineer September 1, 2025 Construction, Estimating Labor Law Page 1 of 1 Town of Southold-Building Department Southold Town Hall 53095 Main Road r� ill? f� PO Box 1179 U� E V E Southold NY 11971 S E P 2 2025 Re: 2445 Private Rd-18 Mattituck,N.Y. 11952 Building Permit Number—52181 Inspection—Reinforcement for In-ground Pool On September 1, 2025, I verified the pool construction at the noted location. The verification covered the steel reinforcement for the concrete shell of the In-ground Pool. The inspection results are: Steel Reinforcement—The proper type and size of rebar was used for the installation. The rebar was correctly fastened and spacers were installed to keep the rebar in place during the concrete installation. The vertical and horizontal spacing of the bar for the walls and base was done properly. Result-All construction was done in compliance with the applicable sections of the IRC, NYS and Southold Town Building Codes. Nicholas Mazzaferro Nicholas J. Mazzaferro, P.E. o Fw Ce u o . w =w �O 05709., AROFESSIONP� FIELD INSPECTION REPORT DATE [_t COMMENTS ._..._... ._. FOUNDATION (IS1') - r Z1 _.. FOUNDATION (2ND) N1 o -c. ROUGH FRAMING & ----- -- _ _-_ PLUMBING -- �cn O ` � 1 INSULATION PER N. Y. STATE ENERGY CODE . FINAL ADDITIONAL COMMENTS -eoor- 9-Li ----- --- ----gam, - 70 ......... _- - - _.- - - --- -- - --.-- ---- -- -- - -- - -- _ z 'ern -o O o��gUFFOCKcoG� TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold, NY 11971-0959 • Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT �j (( For Office Use Only PERMIT NO. ✓ ll Building Inspector: AUG 1 2 2025 Applications and forms must be filled out in their entirety. Incomplete applications will not be accepted. Where the Applicant is not the owner,an Building Department Owner's Authorization form(Page 2)shall be completed. Town of Southold Date: OWNER(S)OF PROPER : Name: SC TM# 1000- Project Address: .-Z'445 Phone#: (9 i Io -7 3 i S��© Email: Mailing Address: CONTACT PERSON: Name: Mailing Address: �1 Irr AV TN) & K ;? Phone#: Email: 0L4-1 el Li le.��w�s,,n.6� aot. r-o Q ' ' Vn DESIGN PROFESSIONAL INFORMATION: Name: ► SG�' ` �� Mailing Address: V Phone#: Email: CONTRACTOR INFORMATION: Name: A.. %"ZA -� - -- Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: Will the lot be re-graded? C- es ❑No Will excess fill be removed from premises? ❑Yes IVo Y�GyA a y-� Ar-,t,v 1 P w ,. Existing use of:.propertv.e tnt�rtcied us.e of p etp�rty _.... .... W. ___. -� .. ............ rte cis trse dlstr ct to dhlGh prerrtises is situat tl Are there an: ct�v pants an d re,stiicttdrt . u�th:respec to. this:prbperty? Ejye ! 1 1 ; P IDE.. COPY n t 5 mhapcer 5aiafth0'ficSWn 0.6nAPPF IO K�PE, �Mi�v td�#h�ssartd6t�I?� r# Sri#f�r23 rs�u�ts� at ��a4it�n�P� �#�ttt��a �t 2ts� usd�n� n4- 4ilrafx �Csrts�strtrict,a�ailadari .tvtswit 1ff , tlt� 1ir:ifQr � rrttnf ? Ii ��e�ditdt�tts,�d1t ^�#dansl`�r ctrzaecsval�ar, �tndl'6tdacr��h�rel�s af�scrcd7 �p�{d �t�agr��s tta� # ��#h ait a�.sdr�a4t�-.1av,�;utart�r6s;dasiii�` �r�efe� stlti4dt #lasiidsti#�trari�s, icta�u'dsns} FK� rgrtq�Fa & ertnar t#aisd �tas� rratsarsrtan# s�?t 1� rrt3�eYatta i a � .n. ., APplicatop Suan3ttc $y.( n'ot nami. QAut ortzed Agent COWner Siomvror.ofppticartt f___q_bVNIE D. 3UNCH Notary PtIblici State of New York STATE OF NEW YORK) No.01 BU6185050 - ss, Oualified in Suffolk County p� COUNTY OFt��wti �� _ �: Commission Expires April 14,2.01 .... o a _ eiri :d:z#y s trc�ri ;.c#epo es: nc says Chat s}he is:the=gip licant: (Name (individual signing:co,tract) ove named, (S)fie Ms the.: _.. (C-011tl actor,Agent,Corpprate Officer,etc.): of:said.owner ar o ners.,and is duly Author zed to perforrrd.of.have;perfgrrpied:the said: ter .artid to ma d���file this aPp#icat ori,that ail staternents:ec pttait ed in this:appf,cat€on are true to the.best cif his/l7er know dge and biehef,:an..d 'that'the wark.aril!be:performed in the manner se:t forth n-the Apia#ieatiort file th:erei ltli. Sworn hefo.r:e ripe this _�A y of , hotary 0 Ublic � � ( re thepplica;nt is no thewrer residing at. h°.,..., to Weby.authdrize i irtt :: fir. r r-ra /`�t :,. to apply on rnv behalf to the.Qwn:of Southold. Roildin Departmernt fir appr mat as dies.crlb d here:ir.- owner':s Signature late Print:Q:wner's Name =opSUFFot root TOWN OF SOUTHOLD—BUILDING DEPARTMENT y x Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax(631) 765-9502 https://www.southoldtommny-.Rov s d Date Received IV F APPLICATION FOR BUILDING PERMIT For Office Use Only ® C E E PERMIT NO. Building Inspector: SEF 1 g 2023 Applications and forms must be filled out in their entirety. Incomplete applications will not be accepted. Where the Applicant is not the owner,an Building Department Owner's Authorization form(Page 2)shall be completed. Town of Southold Date:18 September 2023 OWNER(S)OF PROPERTY: Name:A. Paul Seck SCTM#1000- Project Address:2445 Laurel Lake Drive, MAttituck, NY 11952 Phone#:917.731.5820 Email: Seck mvvainc.com Mailing Address`430,St Marks Ave, Brooklyn, NY 11238 CONTACT PERSON Name:A. Paul Seck Mailing Address:430 St Marks Ave, _Brooklyn, NY 11238 Phone#:917.731.5820 Email:P_Seck m .c vvaincom ____.__._ @_ __.____._____________________ _-___._.---.--- DESIGN PROFESSIONAL INFORMATION: Name:A. Paul Seck - MlallingAddress:430 St Marks Ave,Brooklyn, NY 11238 Phone#:917.731.5820 Email: Seck myvainc.com - _ _ -__---.---_-_-____ P-----____@_._--._.---_-_-___._._--------_-----_-_----__.-_-.-____._. CONTRACTOR INFORMATION: Name:NA Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition . Estimated Cost of Project: E Other New pool $$250,000 Will the lot be re-graded? ®Yes El No Will excess fill be removed from premises? ❑Yes RNo 1 PROPERTY INFORMATION Existing use of propegResidential Intended use of property:Residential 'N- I.-Me-c AAWhich premises is situated: one o "q q, Are there any covenants and restrictions with respect to this property? E]YesigNo IF YES, PROVIDE A COPY. 9 Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236.of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,afferation's or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, hou'sing'cbde and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application S.ubmitted B (print name): A. Paul Seck DAuthorized Agent ROwner Signature of Applicant Date: 9.18.2023 STATE OF NEW YORK) COUNTY OF being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the (Contractor,Agent, Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this -day of 20 Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT SOUTHOLD,N.Y. NOTICE OF DISAPPROVAL DATE: October 25, 2023 TO: A. Paul Seck 430 St. Marks Avenue Brooklyn,NY 11238 Please take notice that your application dated September 19, 2023: For permit: to construct accessory in-ground swimming pool at: Location of property: 2445 Private Road#18, Mattituck,NY County Tax Map No. 1000— Section 121 Block 4 Lot 7_1 Is returned herewith and disapproved on the following grounds: The proposed accessory, on this nonconforming 75,047sq. ft. lot in the R-80 District, is not permitted pursuant to Article III, Section 280-15, which states accessory buildings and structures shall be located in the required rear yard. The accessory will be located in the side yard. Authorized Signature Note to Applicant: Any change or deviation to the above referenced application may require further review by the Southold Town Building Department. CC: file, Z.B.A. FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT SOUTHOLD,N.Y. NOTICE OF DISAPPROVAL DATE: October 25, 2023 RENEWED: April 12, 2024 TO: A. Paul Seck 430 St. Marks Avenue Brooklyn,NY 11238 Please take notice that your application dated September 19, 2023: For permit: to construct accessory in-ground swimming pool at: Location of property: 2445 Private Road#18, Mattituck,NY County Tax Map No. 1000—Section 121 Block 4 Lot 7_1 Is returned herewith and disapproved on the following grounds: , The proposed accessory, on this nonconforming 75,047sq. ft. lot in the R-80 District, is not permitted pursuant to Article III, Section 280-15, which states accessory buildings and structures shall be located in the required rear yard. The accessory will be located in the side Authorized Signature Note to Applicant: Any change or deviation to the above referenced application may require further review by the Southold Town Building Department. CC: file, Z.B.A. BOARD MEMBERS *of S®UT�o Southold Town Hall Leslie Kanes Weisman, Chairperson �® �® 53095 Main Road • P.O. Box 1179 Southold,NY 11971-0959 Patricia Acampora Office Location: Eric Dantes �p� Town Annex/First Floor, Robert Lehnert, Jr. l 54375 Main Road(at Youngs Avenue) Nicholas Planamento y�ou ,� Southold,NY 11971 RECEIVED 4- http://southoldtownny.gov �oA 0 3:2�,PSI ZONING BOARD OF APPEALS L1AU 6 2024 TOWN OF SOUTHOLD � AUG 2 1 2024 � Tel. (631) 765-1809 Southold Town Clerk Bulld!ng Department Town of Southold FINDINGS, DELIBERATIONS AND DETERMINATION MEETING OF AUGUST 15,2024 ZBA FILE: #7931 NAME OF APPLICANT: A. Paul Seck PROPERTY LOCATION: 2445 Private Road#18, Mattituck,NY SCTM#1000-121-4-7.1 SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this application and determines that this review falls under the Type II category of the State's List of Actions, without further steps under SEQRA. SUFFOLK COUNTY ADMINISTRATIVE CODE: This application was referred as required under the Suffolk County Administrative Code Sections A 14-14 to 25,and the Suffolk County Department of Planning issued its reply dated April 24, 2024 stating that this application is considered a matter for local determination as there appears to be no significant county-wide or inter-community impact. LWRP DETERMINATION: The relief, permit, or interpretation requested in this application is listed under the Minor Actions exempt list and is not subject to review under Chapter 268. PROPERTY FACTS/DESCRIPTION: The subject property is a nonconforming 75,047 square foot parcel located in the R-80 Zoning District. The northerly property line measures in total 243.62 feet and the north easterly corner is adjacent to a 20 foot wide Right of Way that runs southerly from Sound Avenue a total of 200 feet to the northeasterly property line and continues as a gravel road aka Laurel Lake Drive, and then turn to the property entrance as Private Road #18, the easterly property line measures a total of 353.65 feet, the southerly property line measures 200.00 feet and the westerly property line measures 353.61 feet to a northwest corner that measures 72.29 feet then turns northwest measuring 54.00 feet to the northerly line. The parcel is improved with a one-story frame dwelling with an attached underground garage and an accessory detached 22.98 ft. by 30.19 ft. garage located north of the dwelling toward Sound Avenue and a fenced garden west of the dwelling as shown on the survey map prepared by Tomasz Suwala, LS, and dated February 9, 2023. BASIS OF APPLICATION: Request for a Variance from Article III, Section 280-15 and the Building Inspector's April 12, 2024, Notice of Disapproval based on an application for a permit to construct an accessory in-ground swimming pool; 1) located in other than the code permitted rear yard; located at: 2445 Laurel Lane Drive, Private Road#18, Mattituck,NY. SCTM#1000-121-4-7.1. RELIEF REQUESTED: The applicant requests a variance to construct an accessory in-ground swimming pool. The proposed accessory, on this nonconforming 75,047 square foot lot located in the R-80 Zoning District, is not permitted pursuant to Article III, Section 280-15, which states accessory buildings and structures shall be located in the required rear yard. The accessory will be located in the side yard. Page 2, August 15,2024 v. #7931, Seck SCTM No. 1000-121-4-7.14 ADDITIONAL INFORMATION: The as built accessory garage located near the proposed inground swimming pool is in poor condition and the applicant at the Public Hearing stated the garage will be renovated in the future to act as a probable pool house and storage area, if the variance relief is granted.Although in ground pools are not uncommon in the area, no objections were received. FINDINGS OF FACT/ REASONS FOR BOARD ACTION: The Zoning Board of Appeals held a public hearing on this application on August 1, 2024 at which time written and oral evidence were presented. Based upon all testimony,documentation, personal inspection of the property and surrounding neighborhood, and other evidence, the Zoning Board finds the following facts to be true and relevant and makes the following findings: 1. Town Law&267-b(3)(b)(1). Grant of the variance will not produce an undesirable change in the character of the neighborhood or a detriment to nearby properties. The property is on a private road and there are only 12 residences located around Laurel Lake. The property is heavily wooded and sloped and can only be seen partially from Sound Avenue. However, the applicant has submitted an unsigned and unsealed landscape plan/site plan for proposed landscape plantings that will create privacy from the neighbor's property, the private Road, and Sound Avenue and will also reduce potential noise. 2. Town Law 4267-b(3)(b)(2). The benefit sought by the applicant cannot be achieved by some method, feasible for the applicant to pursue, other than an area variance. Although the property is large it is very sloped with substantial vegetation that would have to be removed. The applicant chose the location so in the future the old garage could be renovated and used as a pool house and storage area. 3. Town Law 4267-b(3)(b)(3). The variance granted herein is mathematically substantial, representing 100%relief from the code. However,due to the location of the old garage,the substantial slopes and trees on the subject property, and the heavily wooded adjacent preserved property which creates substantial shade on that part of the parcel. The proposed pool's location in the side yard is the most feasible location. 4. Town Law &267-b(3)(b)(4). No evidence has been submitted to suggest that a variance in this residential community will have an adverse impact on the physical or environmental conditions in the neighborhood. The applicant must comply with Chapter 236 of the Town's Storm Water Management Code. 5. Town Law &267-b(3)(b)(5). The difficulty has been self-created. The applicant purchased the parcel after the Zoning Code was in effect and it is presumed that the applicant had actual or constructive knowledge of the limitations on the use of the parcel under the Zoning Code in effect prior to or at the time of purchase. 6. Town Law &267-b. Grant of the requested relief is the minimum action necessary and adequate to enable the applicant to enjoy the benefit of an in-ground swimming pool while preserving and protecting the character of the neighborhood and the health, safety and welfare of the community. RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing test under New York Town Law 267-B, motion was offered by Member Acampora, seconded by Member Planamento, and duly carried, to GRANT the variance as applied for, and shown on the Landscape Plan/Site Plan for plantings prepared by A. Paul Seck, Registered Landscape Architect, last revised August 3, 2024 SUBJECT TO THE FOLLOWING CONDITIONS: 1) The applicant shall maintain landscape screening in perpetuity. Ir Page 3, August 15,2024 #7931, Seck SCTM No. 1000-121-4-7.14 2) Pool pump equipment/mechanicals must be located a minimum of 20 feet from any property line or be contained in a shed type enclosure with a lot line set back that is in conformance with the bulk schedule for accessory structures 3) Drywell for pool de-watering shall be installed This approval shall not be deemed effective until the required conditions have been met.At the discretion of the Board of Appeals,failure to comply with the above conditions may render this decision null and void That the above conditions be written into the Building Inspector's Certificate of Occupancy, when issued. The Board reserves the right to substitute a similar design that is de minimis in nature for an alteration that does not increase the degree of nonconformity. IMPORTANT LIMITS ON THE APPROVAL(S) GRANTED HEREIN Please Read Carefully Any deviation from the survey, site plan and/or architectural drawings cited in this decision, or work exceeding the scope of the relief granted herein, will result in delays and/or a possible denial by the Building Department of a building permit and/or the issuance of a Stop Work Order, and may require a new application and public hearing before the Zoning Board of Appeals. Any deviation from the variance(s)granted herein as shown on the architectural drawings,site plan and/or survey cited above, such as alterations, extensions, demolitions, or demolitions exceeding the scope of the relief granted herein, are not authorized under this application when involving nonconformities under the zoning code. This action does not authorize or condone any current or future use, setback or other feature of the subject property that may violate the Zoning Code, other than such uses,setbacks and other features as are expressly addressed in this action. TIME LIMITS ON THIS APPROVAL: Pursuant to Chapter 280-146(B) of the Code of the Town of Southold any variance granted by the Board of Appeals shall become null and void where a Certificate of Occupancy has not been procured,and/or a subdivision map has not been filed with the Suffolk County Clerk,within three(3)years from the date such variance was granted. The Board of Appeals may, upon written request prior to the date of expiration,grant an extension not to exceed three(3)consecutive one (1) year terms. IT IS THE PROPERTY OWNER'S RESPONSIBILITY TO ENSURE COMPLIANCE WITH THE CODE REQUIRED TIME FRAME DESCRIBED HEREIN.Failure to comply in a timely manner may result in the denial by the Building Department of a Certificate of Occupancy, nullify the approved variance relief,and require a new variance application with public hearing before the Board of Appeals Vote of the Board: Ayes: Members Weisman(Chairperson), Dantes, Planamento,Acampora and Lehnert. (5-0) �eslie Kanes Weisman 71rperson Approved for filing / /2024 FQ Albert J. Krupski, Jr. ��°Sup STORMWA\' IER. SUPERVISOR I\\l[A\NA\G1EM1EN`]F SOUTHOLD TOWN HALL-P.O.Box 1179 v' 53095 Main Road-SOUTHOLD,NEW YORK 11971 ® Town of Southold CHAPTER 236 - STORMWATER MANAGEMENT REFERRAL FORM ( APPLICANT INFORMATION TO BE COMPLETED BY THE APPLICANT ONLY FOR PROPERTIES ONE ACRE IN AREA OR LARGER. ) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - APPLICANT: (Property Owner, Design Professional, Agent, Contractor, Other) NAME: Date: (Print) •� a i _ 0 1 Z S (Signature) J• Contact Information: a4 --1 a 14 a, (E-Mail 8 Telephone Number) _ Property Address / Location of Construction Site: S.C.T.M. #: 1000 District s l q _ 7 / Section Block Lot TO BE COMPLETED BY SOUTHOLD TOWN ENGINEERING DEPARTMENT - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Area of Disturbance is less than 1 Acre. No S.P.D.E.S. Permit is Required! ❑ - Project does Not Discharge to Waters of the State. No S.P.D.E.S. Permit is Required ! ❑ - Area of Disturbance is Greater than 1 Acre & Storm-water Runoff Discharges Directly to Waters of the State of New York. THE APPLICANT MUST OBTAIN a S.P.D.E.S. Permit DIRECTLY From N.Y.S. D.E.C. Prior to Issuance of a Building Permit. ❑ - Area of Disturbance is Greater than 1 Acre& Storm-water Runoff Flows Through Southold Town's MS4 Systems to Waters of the State of New York. THE APPLICANT MUST OBTAIN a S.P.D.E.S. Permit through the Southold Town Engineering Department Prior to Issuance of a Building Permit. Reviewed BY: Date: '? / 3 FORM _# SMCP-TOS December 2024 eceevec g �3 aft POINT OF COMMENCE /_- qp 0, r"IR-PPROVAL POINT OF BEGINNING 20.0' UP a\ s \\ END OF \ �, 0S1 U 6Z \\ GRAVEL SO,, 0 T� s sy LU �G 11 35• s N 36' v FIRE PLACE pp� 37'3.6'N �090�. g 1136 Pavin Surface ,�p0• r L�� S MoN�MEN /� Edge �� cONG. FOUND \ 36' W SNR�gs U 1n GENERAL NOTES: TREE LAWN 39 LAWN / \\ 1. LOT AREA:75,047 sq.ft. 2. CERTIFICATION INDICATED HEREON SHALL RUN ONLY TO THE PERSON gyp`\ \ g0013� - � ° I n round Pool- FOR WHOM THE SURVEY IS PREPARED AND ON HIS BEHALF TO THE TITLE COMPANY,GOVERNMENTAL AGENCY,LENDING INSTITUTIONS '� \ 16,X5O1 AND ASSIGNEES.CERTIFICATIONS ARE NOT TRANSFERABLE. LOC �,� CONC. MONUMENT FOUAVD� 41' \ F 3. THE EXISTENCE OF RIGHT OF WAY AND/OR EASEMENT UNDER OR ABOVE GROUND OF RECORD,IF ANY,NOT SHOWN ARE NOT 42;_\/ \\ CERTIFIED. TREES & SHRUBS - " \ \ 4. THERE WERE NO NATURAL STREAMS OR WATERCOURSES VISIBLE AT \ THE TIME OF THE FIELD SURVEY. 5. ENCROACHMENTS AND VAULTS,IF ANY,BELLOW SURFACE NOT 44' \ (((�� SHOWN HEREON. 2 \ GRA!EL EL45.o ""T \ 6. THE OFFSETS SHOWN ARE NOT TO BE USED FOR CONSTRUCTION OF aRi�U a r Io EL.45.35'v�'� 36'. 43' ANY STRUCTURE,FENCE,PERMANENT ADDITIONS,ETC. 55 % " " SPRUC Q Na \ A 2 ( py`1y SPRUCE 0i 01, O o x 44' O \ p)O \ s ` q5' EL46.12' LL o 7" \ P� 7 \ �J S61 ��• ��''/ `\ G �� EL46.15'SPRUCE 45• �( J`�\ \ REFERENCES: 1. DEED LIBER 22325 PAGE 81 L''ONC. MONUMENT FOUND� �'ys1 GQ�GGE 52 , k P P y6y �y SPRUCE 46' 2. FILED MAP XXX G i � TREES & SHRUBS G�� I EL45.84' �Z�G 43" EL46.28 <\ P \ SPRUCE CONC. 76" �PAVER SPRUCE PATIO CELLAR ENTRf41VCf EL 4.05' LAWN �V 47 \\ ti \ SPRUCE + 19.9'\F, X up �ti \ Existing Buildin o Remain J -�� tiro \ \ \ CERTIIFICATIONS: CESSPOOL GREASE TRAP \' \ and Be Renova � \ ' EL.42.�9 �.\ �' 1'�` a6��IG�°-, S. `o G. �46, 96.1 \ 1. PAUL SECK • 67 \ \ P�1 GQ� �O00. J GPRtQSy' S\ [oc O� �ysy�� ,�9' LAWN \ SIRE / x� �ER 1 \ CONC. \� 45' \ J oo \ >_ STEPS � � \ CONC. PAVER WALK j \ Q, 25.5' R OF 0VFR \\ CONC. A'PQN / \ 44' / \/ 55.0 CONC PAVER STEPS \ \ -43' �. \ 133.0' � 42' j \ 'R \ LAWN `GRAVEL DRIVEWAY—' LOC F <v �X Q� \bUP \ \ / AU FX �/OO 41' x \ TS LAND SURVEYING PC \ \ EL.40.02' 140 FELL COURT,SUITE 120 �\ 11 . 86 LAWN TEL: (63)439-0762 E,E-MAIL:INFO@TSLSPC.COM MAPLE 39'_�� BOUNDARY SURVEY 0.9' coNc. STONE\38' 2445 LAUREL LAKE DRIVE,MATTITUCK,N.Y.11952 RETAINING WALL DISTRICT:1000 SECTION:121.00 BLOCK:04.00 LOT:007.001 LOC 37• TOWN OF SOUTHOLD COUNTY OF SUFFOLK,STATE OF NEW YORK 35' \� SURVEYED BY:C.K. F.B./PAGE: DATE:02-02-2023 Sol- DRAFTED BY:M.R.T. CHECKED BY:T.S. DATE:02-09-2023 UNAUTHORIZED ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION 9 OF NEW YORK STATE EDUCATION LAW 34' / �R��S 00 COPIES OF THIS F SECTION OSURVEY MAP NOT BEARING THE LAND SURVEYOR'S EMBOSSED SEAL AND SIGNATURE SHALL NOT BE CONSIDERED TO BE A TRUE AND VALID LEGEND: COPY E[. - SPOT ELEVATION 33' 2445 Laurel Lake Drive, Mattituck7 NY 11952 TOMAYS'Z SUft'LA FF - FIRST FLOOR / Pool Location .NrSEDATE: 57 R- RIDGE �s� SIGNATURE DATE: G- CARAGE AC - AIR CONDITIONING UNIT 12 October 2023 CONC. - CONCRETE •��� LOC - LINE OF CLEARING UP - UTILITY POLE \ LOC \ � i 061 A. Paul Seck- 917.731 .5820 PROJECT NO.:1668-23 SCALE:1"=20' SHEET:1 OF 1 ��r v a mere ���MS°Iirt..M1.' 503. 1 Y"Yam^ �• NTT•3d � iR ,,........, i I 'COOS s t �yNRs �NjO� ' E SII JJ R 4 � r0s .,1 a F I TOPOGRAPHIEALSURVEY • •� AREA 7SD44I 1.723 Rtre V /�E�C C0NST11UCf10N DATE:JANUARY15,2025 I�YJC IANDSURVEYING n J i�i'E,S�f�\• B1M 79tN STREET MIDIPHONI AGE NY31379 Nv FA%E13d�1 J30-669181.84 5 WWW.CSESUWAIA.COIA j T MATTITUCI( /•i A TOWN OF 5OUTHOID Amw aJ COUNTYOFSUFFOW STATE OF NEW YOW DISTRICT1000 SECTION 12100 BLOM D6.G0 L0T 007.001 ARKADIU.11L,IEGA,LS NY50505E9 F� Wort: y S IF nAVTHORIRED A0FRANON 0RAD0010N TO TH6 SVWIT IS A VIOLATION OF SFCIIOH>ID9 0 6E TEOW IOMSTAY F�OUOITI`NN LAW. wmJnoxs ws FD sFu DR rNmsSrD SFq.514yy n06RE<On510ERI0 VfA H.RUNpUE�IAR'. �O:mINGIIOH VV%N'HF0.FCIJSWII RV 0x[STOTNE VERwNwRIVHDMTIE ISLPINmcm6nit0m nN65iio n�oiE irtIF MNPiMOVEWMFMIGNL A4FHANO nF�F:RYI.6FL'�JP"Lv:5iER4 M40roD11W�it�'S11NM.SOn5L9SE�UE.+Ci+Es3 ��- �• OUt0NIF0.0Y0RM50RFNN0AEN NRIFPXJ.MF NDf RNgvx HEREON � 60 -- _ - -__-0t 9d EIfVATION MFERSTOOgNMNAVORR CERTIFIED TO: S6\ THEE%ISTENCE OF RIGHT OF WAY AND/OR EASEMENT S.DEPARTMENTOFBUILDINGS a•' OF RECORD,IF ANY,NOTSHOWN ARE NOT CEITIFED. 10F.1; d 0 In-ground Pool specs-16'x50' tiyo °3 3-5'-8'Depth c�OU �p 1_t� 8'Dia.Drywall- Location to be • 8"Shell and 10"beam- %"Reber(10"centers,5"verticals) Determined During • (2)Main Drains " Construction • White or gray marble dust finish • Porcelain 6" x24" Liles Paving Surface • Pre-fab cement equipment pads Edge • High grade 2"solid PVC plumbing ao>dE0 • (3)Skimmers • StaRite Modular Media Filter(or equivalent) • (6)Returns pv �'r • Pentair Variable Speed Pump 4's • Stairs as per plan • Pentair Chlorinator e • Individual Suction Line v • 2 Pool draw plans a r o • Jandy never lube valves and unions Levlo • (6)12 electronic autofill .,, +c• �.i �` . (6)12v LED Lights (! 'a G Ay4S %Ltr kA .�.�.e.,<..be/ SB•d1a.x8•Swimmin9Pad� �" .'.. �`��.a^�4'' ,r Ls7 i= 0,�, •ixm Drywall.Final Location t°be Dete .d During Cans don oT 4W'C�M Ped a�Pccl Equipment Foisting Building fo Remain and _:1_� :�-, //%/ Ca •, �. y B.R novated .> The proposed site plan uses the survey as described below. 10 / 2445 Laurel Lake Drive,Mattiluck,NY 11952 mpa �e����a➢N4 ro~ s3 Pool Location r. 16 April 2024 e�o�uo A.Paul Seck-917.731.5820 o• S - A • S \� o a Dry, �r I11Aq�U011►.y8,11A 1�� 7� 1 � -`�imLo�ioe1Dm611D4, • ��a p ' ADADAmAAADAD �• $—Y�DD^ maADDDAHDDOAD P a imm m f 1 A AILD m � y, \r .• n.. ADm A bw aDA we;D i gnu D iv m `�' s�'��1� • sma� a Dp:: oa - �j � � GiDaSirriB . e 1R4 s ♦ OR re e ��.. . • - o a��a p�� � eea � ��� �:':..© :? r:•T�sa:�• m �, \� �- 0• (�l�.+� d�` %ai'u�;•7 �<2.fi' .';�� �of AY2w/�caMECACE ' 1 \)V s r? . s In-ground Pool specs- 16'x50' °,.sQ� 3-5'-8' Depth�',o;r° .1Lr0.tARwc 8' Dia. Drywell- ���m" �° SQ Location to be • 8"Shell and 10"beam- t/2"Rebar(10"centers,5"verticals) s°es, Determined During • (2) Main Drains W ,A36z °F Construction • White or gray marble dust finish 2. • Porcelain 6"x24"tiles Paving Surface • Pre-fab cement equipment pads Edge • High grade 2"solid PVC plumbing • Stag t Modular Media Filter(or equivalent) • (6) Returns v� \ , ''a6s • Pentair Variable Speed Pump Golf . • • Stairs as per plan • uKM • Pentair Chlorinator GENERAL NOTES. TOOx L°" • Individual Suction Line 1. LOTAREA:]5.047 y.k o E s 2 Pool draw plans 2 CERIINCATIONINDICATED HEREONSHALLRUNONLYTOTHFPERSON • O QO \\ U RAS FOR WHOM THE SURVEY IS PREPARED AND ON HIS BENALF TO THE N19 .a �V .yam TIRE COMPANY,GOVERNMENTAL AGENCY,(ENDING INSTITUTIONS R , 1 • Jandy never Tube valves and unions AND ASSIGNEES.CERTIFICATIONS ARE NOT TRANSFERABLE. COAL ARMY/AkNr FOUND •! 1v/��^{ °Re • Levlor electronic autofill 3. THE EAISTENCE OF RIGHT OF WAY AND/OR EASEMENT UNDER OR • —��' ABOVEGROUNDOFRECORD,IFANY.NOTSHOWNARENOT '•MINES, CERTIFIED a— ••� \f\\ • ( ) 2vLED Lights THERE WERE NONATURAL UMSTRE SORWATERCOURSESVISIBLEAT THETIMEOF I TH NA VEY, 1. SENCROACHMENTS AND VAULTS,IF ANY,BELLOW SURFACE NOT HOWN HEREON. !'3 PO(9L C` 6 THE OFF ANY STRUCTURE.SHOWN PERMANENT ARE NOT TO BE ADDITIONS,D FOR CONSTRUCTION Of DDITIONS,ETC. - , AUG 13 2024 REFEREE 0 BER 113E5,PAGE 81 r 8'dia.x 8'Swimming Pool if, Drywell. Final Location to be I ••• 2. HLEDMAPM mEEs:sN.vues w� Determined During Construction ,• jr/ " I� � ��\ , �' ZONING BOARD OF qpp EALS PLANT LEGEND 4'x8'Concrete Pad and Pool 190 6 Equipment CERTIFICATIONS: Y,, -vqa cAE.LrE new Arborvitae"Green Giant" Existing Building to Remain and 1. PAULSEOY Be Renovated ' y �y �dV E�pSP / NOSCAP O Sassafrasalbidum La �F Soa� * �► L � \ ,\�` ����°PAULSE�rFv�ci • � LRR1w ArLi<P IwL.r �, 9�. oo26zT O Cryptomeria japonica `uy. FOF NE`N "yoshino" aNc aLOP `, , ss.a IC aAFra s2En , • o , 133.a The proposed site plan uses Betula popolifolia-gray ,r , birch ` the survey as described below. ticA A' TS LAND SURVEYING PC 141 FELL COURT,SUITE IM • Mix is �B UYN TEL 1631M"762 hAUPIPAUGE O Pieris E- NL NFOERTSLSPC.COM japonica .FIaE Rhus aromatics s Hydrangea BDUNDARr wRNEY Hibiscus o9 LYNC: 2M5 UUBELWDRIVE,MATTITUCK,N.Y.11"2 BBu s B pFA WI�fromSA Lx # ftal revIIw*d duets DISTRICT.1000 SECTION:121.00 BLOCK:DAM LOT:007.001 TOWN OF SOUTNOLD Extent bulbs to the det error ned at a aterr da e. and y 2 t / COUNTY OF SIFFOIII,STATE OF NEW YORK ,A SURVEYED BY:C.K. /PAGE: DATE:02-0-2023 ,A�"- DRAFTED BY:M.R.T. CHECKED BY:T.S. DATE:02-0 W23 Exact location�}trees may Vary. Y UNAUTHORREDALTER nONORADDITIONTOTHIS%RVEYISAMOLATION IF,�,c5' OF SEMN T208 OF NEW YORK STATE EDUCATION LAW SY Il- COPIESOFTHISWRVEYMAPNOTBEARNGTHEU DSUNVEYpLY EMBOSSED SEAL AND SGW3TU0.E SHALL NOT BE CONSDEAED TO BE A TRUE AND VAUD zerISM° CDPY 2445 Laurel Lake Drive, Mattituck, NY 11952 FO 2z-SPor E2E1NY.ew ar mrAss suru FF-E."sr A20L3P Ism POOL LOCATION AND TREE PLANTING PLAN N>spaFFr REVISION DATE-3 AUGUST 2024 LOC-LI1E�IXEAMIG U^-U1.LO'AafE LLC �oti'A A. Paul Seck-917.731.5820 o� PROIELT NO.:16 3 SCALE:1-20' SHEET:1 OF 1 POINT OF COMMENCE f `Y1\ T�le S'so" POINT OF BEGCNNINIG \\ "� 20.0' OP a\ O F S \\ GRA F EC \\ 08 SO,, o 1p3 62 \ P \ TP \ IFS \ Sy 3 N11e 36, -FIRE PLACE \ El �3.6'N 37' \ �4ya \\ •7156 U MrNT SNRU85 CONC. MONO 3e' \\\\ GENERAL NOTES: rREL LAWN CAWN 1. LOT AREA:75,047 sq.ft. 39' 2. CERTIFICATION INDICATED HEREON SHALL RUN ONLY TO THE PERSON QO QO Y ��P �6e FOR WHOM THE SURVEY IS PREPARED AND ON HIS BEHALF TO THE TITLE COMPANY,GOVERNMENTAL AGENCY,LENDING INSTITUTIONS LOC \ AND ASSIGNEES.CERTIFICATIONS ARE NOT TRANSFERABLE, CONC MONUMENT A000 41' ?� \\ �. 3. THE EXISTENCE OF RIGHT OF WAY AND/OR EASEMENT UNDER OR ABOVE GROUND OF RECORD,IF ANY,NOT SHOWN ARE NOT \ CERTIFIED. TREES&SHRUBS 42 \ \\ \ 4. THERE WERE NO NATURAL STREAMS OR WATERCOURSES VISIBLE AT A \ THE TIME OF THE FIELD SURVEY. N( \4Y• S. ENCROACHMENTS AND VAULTS,IF ANY,BELLOW SURFACE NOT 44' � \ SHOWN HEREON. ?i GR4VEC 6. THE OFFSETS SHOWN ARE NOT TO BE USED FOR CONSTRUCTION OF ORIVEWAY� EL45. ' 43' ANY STRUCTURE,FENCE,PERMANENT ADDITIONS,ETC. �O 0.45.35'q SPRUC Q0, O v -yT3 Rh1' SPRUCE µ EL46.17 \\ v 61 0�101 > GPSE 77„ ��\ C3 1 �O, EL.4&IW5pRUCE ,�• ((.. �\\ REFERENCES: '�\ �c� CONC MONUMENT FOUNO� G0NGGE e'1 52 1. DEED UBER 22325,PAGE 81 " c^� Gl'' 0'° 1 RP SPRUCE 46• �a 2. FILEDMAPXXX TREES c7 SHRUBS ��yo,6� I EL45.84' z� P � c 30>9 G0� 43" EL.46.28' SPRUCE CONC SPRUCE PAIER-\ CELLAR ENTRANCE Gy`yry PAT/O \ 47' \ LAWN1 \ 32 SPRUCE + ky \ 19.9' x k' �qUP CERTIFICATIONS: CESSPOOL GREASE TRAP , / p EL42. ` ♦N .I t1 It, G 46 96.1' \ 1. PAULSECK 67" Go F�E0 fY \Q�r1��V�k�9wk/ / \ LOC G�GLO5E 5 GE 5 Q F`" °gbh, 519 6 CAWN , \ \ \\ �! \\ Gde CONC u• A� \ 110 STEPS \ \CONC. PAVER WALK \ 00, R OVER \\ CONC A 44' \ 55.0' CONC PALER 57EP5 \ 43' \ 133.0' \ 42' \ `-GRAVEL OR/I'EWAY-- LOC Q� \bUP LAW/N� X 41' TS ,cyELL440.07 140 FELL IO E COURT,S SURVEYING P SUITE 20 �CeF �40• LAWN HAUPPAUGE,NEW YORK 11788 B6" EL: (631)439-0762 E-MAIL:INFO@TSLSPC.COM MAPLE 39' BOUNDARYSURVEY 09'CONC STONE 38' 2445 LAUREL LAKE DRIVE,MATTITUCK,N.Y.11952 RETAINING WALL DISTRICT:1000 SECTION:121.00 BLOCK:04.00 LOT:007.001 LOC 3T� TOWN OF SOUTHOLD COUNTY OF SUFFOLK,STATE OF NEW YORK COC --�-35• SURVEYED BY:C.K. F.B./PAGE: DATE:02-02-2023 P�gS DRAFTED BY:M.R.T. CHECKED BY:T.S. DATE:02-09-2023 5� UNAUTHORIZED ALTERATION OR ADDITION TO HIS SURVEY IS A VIOLATION OF SECTION 7209 OF NEW YORK STATE EDUCATION LAW 34' SREES$ COPIES OFT S SURVEY MAP NOT BEARING HE LAND SURVEYOR'S EMBOSSED SEAL AND SIGNATURE SHALL NOT BE CONSIDERED TO BE A TRUE AND VALID LEGENO COPY EL - SPOT ELEVATION 33 FF- FIRST FLOOR R- RIOGEO E- SAVE NYS#'051157 ��OF NEW,, G- GARAGE AC -AIR CONOITIONING UNIT CONC - CONCRETE COC - CLNE OF CLEARING UP- IITIL17Y POLE COC �V 051157 O� S63 �CANDs � PROJECT NO.:1669-23 SCALE:1"=20' SHEET:1 OF 1 Swimming Pool Pro Inc. 27 Franklin Ave. Mastic, New York 11950 Direct Dan (631) 204-7042 or Eileen (516) 668-2588 Paul Seck March 24, 2025 2445 Laurel Lake Dr Mattituck, New York 11952 Please find Contract below to build approximate 16' X 50' Gunite Swimming Pool at above referenced address: Obtain Permit Obtain Structural Drawings Excavation Dirt to stay on site and be placed in hole in front of property Rough Grade 6' around pool Steel 3/8" Rebar, 10" on center with 6" Verticals in deep end Depth - 316" Shallow 8' Deep End Steps in Shallow End, (Per Plan) Love Seat - (1) 5' Bench Coping - 2" Blue Stone Thermal Tread (Client to decide coping $27.00 Linear Ft allowance Tile - 6" band around top of beam (Client granted $13.00 Sq Ft Allowance) Marble dust (White or Shade of Grey) 3- Skimmers with separate plumbing lines and valves at system, tiled around sides and base of mouth 6 -Wall Returns 1- Main Drain - Interconnected to meet code 6 - Pentair LED Low Voltage Lights (Discuss with client) 1 -Automatic Chlorinator 1 - Hayward VS 700 Variable Speed Pump 1 - Hayward 4800 DE Filter Water Boding anode to meet electrical code Rheem 400,000 BTU Electronic Ignition Propane Heater Jandy Check Valve for heater All Underground Plumbing lines to be 2" 100 Psi Poly Pipe All Above ground Plumbing Lines to be 2" Sched. 40 PVC Pipe Manifold at system will have 4 - 2" Jandy Never Lube valves and 2 - Sched. 80 quick disconnect for ease of service Water Bonding Anode ` v Concrete slab for filter system to sit on Drywell to meet Southold town code requirements Alarm - 1 Pool Guard PGRM - 2 with Remote Receiver Swimming Pool Pro Inc will provide and install two door alarms, one with pass through feature to meet building code Loop-Loc Winter Safety Cover (Installation to be billed separately) Swimming Pool Pro will run electrical conduit from pool area to system area only Prices for the above Gunite Swimming Pool $999250.00 Note: Gas hook-up provided by others Electrical work to be done by others Salt system to be added to contract. Swimming Pool Pro Inc will install salt system with this contract for the cost of said salt system chosen. If client decides to go with color show lights, swimming pool pro will add color show lights per cost between color show lights and regular LED lights. Water will have to be trucked in, Water cost paid directly by the client. Swimming Pool Pro Inc will coordinate delivery Payment Schedule: Pay #1 $ 9,925.00 Due on Signing Pay #2 $ 4,962.50 Due on Completion of Framing Pay #3 $ 39,700.00 Due on Day of Gunite Shoot Pay #4 $ 149887.50 Due on Completion of Filter System Pay #5 $ 14,887.50 Due on Completion of Coping and Tile Pay #6 $ 9.925.00 Due on Day of Marble dust Pay #7 $ 4,962.50 Due on Completion of project I agree to the work stated, materials, and Payment Schedule of this contract: Homeowner Signature Dated Swimming Pool Pro Representative Signature Dated Contract Price good for 30 days IyAn ALL PIPING TO BE / \ \ 2"PVC \ 6"TILE BAND —► ° �ZnMPACl ED, 12AJ!J%; I i I i (WATER) _ _ °© GFj r — — — — — — — — — — — — — — — — — — — — — — — — — - MARBLE DUST —► '> I SKIMMER SKIMMER #4 STEEL REBAR (VERTICAL) ' ," i � � � I DEEP END 12"OC 3 ° I 50"-0" i r — — / \ I I I O #4 STEEL REBAR (HORIZONTAL) I 12"OC a I I \0 O N � � I Orr, SHALLOW END � �' � D (COMPACTED SOIL) 8'dia.,4'deep /-� 12' TO 36"RADIUS ;° ° DRYWELL // I I � (VARIES) � I I G`c 3500 psi s , : � � � � FILTER &PUMP I MAIN DRAIN CONCRETE ' D — — I (MIN.3'APART) RETURN RETURN P O ED AS NOTED I I ;3 8"(MIN.) a ° _ DA B.P.# N II II O _. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - FEE � BY: �! I � �' � d� NOTIFY BUILDING DEPARTMENT AT 631-765-1802 6AM TO 4PM FOR THE FOLLOWING INSPECTIONS: NOTES: 1. FOUNDATION-TWO, ""'^r' 1-1 — — — — —ALL PIPING TO BE — — — / — — _ — — / SWIMING POOLTO BE EXCAVATED ONE FOOT OVER DESIGN SPECIFICATIONS AND 2"PVC SOILTO BE LEFT ON PROPERTY.SOILTO BE STOCKPILED OR RUFF GRADED(AS FOR POURED Ct.:. ;G �� PER OWNER)ON THE DAY OF EXCAVATION ONLY UNLESS SOIL IS TO BE CARTED 2. ROUGH-FRAMING& ; AWAY. 3. INSULATION SWIMING POOL STRUCTURE TO INCLUDE A MATT OF 3/8"STEEL REBAR TIED, 4, FINAL-CONSTRUCTION MUST 12"ON CENTER FOR WALLS AND FLOOR,6"ON CENTER FOR ALL TRANSITION BE COMPLETE FOR C.O. BREAKS AND BOND BEAM. ALL CONSTRUCTION SHALL MEET THE THE POOL SHELL TO BE MADE OF 1-4 DRY GROUT GUNITE MIX SHOT INTO THE STEEL CAGE AT A THICKNESS OF NO LESS THAN 12"ON THE TOP EDGE OF THE REQUIREMENTS OFTHE CODES OF NEW POOL(BOND BEAM)AND NO LESS THAN 12"ON THE WALLS AND FLOOR. YORK STATE. NOT RESPONSIBLE FOR INTERIOR FINISH OF POOL TO BE"PEBBLE TECH"DURABLE FINISH.COLORS AS DESIGN OR CONSTRUCTON ERRORS PER OWNER. 1�iM ALL CODES 01p fZ V�YORt�STATE&TOWN CODES f�S =EMOLDTonz3A f,'DCONDIT10- SO#, w -' rn o a , -� rsrn ARD N w c0 w 0 T,RUSTEES w b..a z law 12" 12" 12" 12" 12" 12" Z � z Lid nq� ..•""� Y J a• . (4)#4 REBAR(TYP.) � .r 'n D , • ' ram' V! Q Q O CO USA , ��TUL IS Y `M z m = r O OCCUPAp (n a: ° n ° OF � �?n` c,r lid �/J LL R.2"(TYR) O r . CONNECT TO c ' REINFORCED UNITE 4 to l'.A 8'X4'DRYWELL BAC:KFLOW FILTER 'S FLOOR REINFORCED WITH RETAIN STORM WATER RUNOFF HAIR&LINT O PURSUANT TO CHAPTER 23& PUMP CATCHER 4 G 4 n Q #4 REBAR AT 12"OC EACH WAY(TYR) .� ,�, '�, n`� �`a c=`� �`�, ra•� � � . � �. , � �� . � , Y OF THE TOWN CODE. "7 V, U n a o O L WATER LINE , DRAWN BY: JF ELECTRICAL. INSPECTION REQUIRED 4/14/25 pI ram. iAT I�Y 2"RETURN MAIN �� �m�� °� , COMPLIES WITH: LbSE POOLTO.CODE TO INLET SECTION R326 OF THE 2020 NYS RESIDENTIAL CODE K #PON G.OMPLETIbN" DRAIN SCALE: SEE PLAN ' ' .= -. SECTION N1103.12 (R403.12) RESIDENTIAL POOLS AND �" bFORE:"WATEf � 2' PIPE�''' °� PERMANENT RESIDENTIAL SPAS SECTION R326.4 BARRIERS SHEET NO: SECTION R326.5- R326.6.5 ENTRAPMENT AVOIDENCE � I • New York State Law You Must Call 811 A— 1 Before You Dig