Loading...
HomeMy WebLinkAbout53122-Z ,�pf SO(/ryOlo Town of Southold * * P.O. Box 1179 aA! 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 47235 Date: 07/23/2026 THIS CERTIFIES that the building AS BUILT HVAC Location of Property: 910 New Suffolk Ave Mattituck, NY 11952 S ecB lock/Lot: 114.-12-8 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 06/24/2026 Pursuant to which Building Permit No. 53122 and dated: 07/14/2026 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "As built" central air conditioning as applied for. The certificate is issued to: Anita Martignetti Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 53122 7/22/2026 PLUMBERS CERTIFICATION: Aut o ' d gnature of Soo TOWN OF SOUTHOLD BUILDING DEPARTMENT e SOUTHOLD, NY ,o BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 53122 Date: 07/14/2026 Permission is hereby granted to: Anita Martignetti 95 Howland Rd Westport, MA 02790 To: legalize "as built"central air conditioning as applied for. Premises Located at: 910 New Suffolk Ave, Mattituck, NY 11952 SCTIVI# 114.-12-8 Pursuant to application dated 06/24/2026 and approved by the Building Inspector. To expire on 07/13/2028. Contractors: Required Inspections: Fees: As Built HVAC $500.00 CO-RESIDENTIAL $100.00 Total $600.00 ----------------------------- Building Inspector SO�ryol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G • Q Southold,NY 11971-0959 UNT`I,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Anita Martignetti Address: 910 New Suffolk Ave City: Mattituck St: NY zip: 11952 Building Permit#: 53122 Section: 114 Block: 12 Lot: $ WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Electrician: AS BUILT License No: . SITE DETAILS Office Use Only Commercial Indoor X Basement Service Solar Residential X Outdoor X 1st Floor Pool Battery Storage As-built X Renovation 2nd Floor Hot Tub EV Charger New Addition Attic Spa Generator Survey ix I Mezzanine Garagel IDock INVENTORY Service 1 ph In-wall Heater Recpt Ceiling Fixtures Smoke Detectors Pump Service 3 ph Hot Water GFCI Recpt 2 Wall Fixtures CO Detectors Heater Main Panel A/C Condenser 2 Single Recpt RecessdFixtures Combo Smoke/CO Transformer Sub Panel A/C Blower 2 Range Recpt Ceiling Fan Heat Detectors Salt Gen Transfer Switch Mini Split Dryer Recpt UC Lights Fridge AutoCover ARC Blower Heads Switches 2 Pucks Lights Dishwasher Mini Fridge GFI Disconnect 2 Emrgency Strobe 4'LED Microwave Garbage Disp. ARC/GFI ERV Exit Lights Bath Exhaust Hood Dehumidifier Other Equipment: Notes: " AS BUILT NO VISUAL DEFECTS " HVAC Inspector Signature: C Date: July 22, 2026 zf so # # TOU �SOUTHOLD BUILDING DEPT. o ffom 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR i/ ho�aOF SO�IyO� # TOWN OF SOUTHOLD BUILDING 'DEPT. coum, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] RO GH PLBG. [ ] FOUNDATION 2ND hSULATIowcAULKING [ ] FRAMING/STRAPPING [ FINAL [. ] .FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION ] FIRE.RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ : ] ELECTRICAL (ROUGH) [ ] ELECTRICAL(FINAL) [ } CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: 1 DATE A %40 INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS C " fro m FOUNDATION (IST) ------------------------------------- FOUNDATION (2ND) � z 0 0 y ROUGH FRAMING& PLUMBING 1 INSULATION PER N.Y. y STATE ENERGY CODE S FINAL ADDITIONAL COMMENTS ZLe IRL�4 ftCC + EL 12-74- o z ro ul N Q4 z �x x d ro s_ =�o�buFFocK�oGy� TOWN OF SOUTHOLD—BUILDING DEPARTMENT H Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 oy�o aa� 'Telephone(631) 765-1802 Fax(631)765-9502 https://www.southoldtomm.gov Date Received APPLICATION FOR BUILDING PERMIT D EC E 0 V E For Office Use Only r J UN 2 4 Z 2026 PERMIT NO. ✓ Building Inspector: Building Deparfrnent Applications and form ,m sust be filled out in their entirety.Incomplete- Town of Southold applications will not be accepted. Where the Applicant is.not the owner,an Owner's Authorization form(Page 2)shall be completed. Date: OWNER(S)OF PROPERTY: Name ap "00F.490b Project Address: Phone#: L' , � Email: dl Mailing Address: r CONTACT PERSON: Name: __ ____ - _ _. __ J ___. _ Mailing Address: Phone#: ,c) Email: DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: r Mailing Address: Phone#: _ - Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑ dition ❑Alteration ❑R t-rlDemolition Estimated Cost of Project: Will the lot be re-graded? ❑Yes la�o Will excess fill be removed from premises? Dyes P<o 1 PROPERTY INFORMATION Existing use of property: Intended use of property: zone or use district in which premises is situated: Are there any covenaM04117 restrictions with respect to this property? ❑Yes YES, PROVIDE A COPY. Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to-the Building Department for the issuance of a Building.Permit puisuant'to.the Building Zone. Ordinance of the Town of Southold,Suffo(k,County,New-York and other applicable_Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant-agrees to comply with all applicable laws;ordinances,building code, housing code and regulations and to admit authorised inspectors on premises and in building(s)for necessary inspections.False statements made herein are, punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted nt name): uthorized Agent ❑Own er Signature of Applic ht: r Date: Zo STATE OF NEW YORK) SS. COUNTYOF �►'I� ) being duly sworn,deposes and says that.(s)he is the applicant (Name of individual signing contract)above named, )he is the I f (Contractor,Agent, Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this nu 1� day of Tlmdr� ,20 (/. Notary Public c vti �z� 3 PROPERTY OWNER AUTHORIZATION�di�,y (Where the applicant is not the owner) I, hur-A residing at Ae h1h71-C-4 do hereby authorize DAIJ ill rt IV 21 to apply on my behalf to the Town of Sou old Building Department for approval as descri ed h rein. Owner's Signature U Date Print Owner's Name 2 ��gufFO(,�CO BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD 0 - Town Hall Annex- 54375 Main Road - PO Box 1179 o • Southold, New York 11971-0959 y�01 �ap� Telephone (631) 765-1802 APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) TT Name: T74 L Address: 9 Cross Street: Phone No.: Bldg.Permit#: -;j?j./a� _ email: d I I lai-c>P—/avvde Tax Map District: 1000 Section: '( : Q Block: Lot: ar BRIEF DESCRIPTION OF WORK, INCLUDE UARE FOOTAGE ( se Print Clearly): ScI are Footage: Circle All That Apply: Is job ready for inspection?: Rle"YESE] NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES [3<0 Issued On Temp Information: (All information required) Service S1ze❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals F1 1 F12 D H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION I STREET ADDRESS; 910 NEW SUFFOLK AVENUE NEir SUFFOLK AVENUE N 88'29'00' E 60.00' Mir SIDEWALK WG�Y{'il`iCS�+C�CS 442.58' I 9 RGV OF CEDARS i cces,F h sra�CtomFIL A Z Ovm Cory P v �z z STY. p lei FP- FIM�g :. FQ� It roco 2r• r2.:• T'E { fSTYi — sz a ti 12-*- SURVEY OF PROPERTY AT MATTITUCK w wx 70 TOWN OF SOUTHOLD SUFFOLK COUNTY, NEW YORK 1000-114-12-08 SCALE: 1"=30' —I WCM JAN. 29, 2002 j DEM FEB.(, 2002 (prop. add l(on 1 OCT. 3,2006(F1N4U o � Y ' v IALL U F � 6.9• �— W as° SHED a } y � U O � z o • z w 0 o CD z ti v 0 b y 6S'ss AREA=20,579 S.F. 4O' OR 0.4724 ACRES _ �PKEOF:NE } 9 NT NIfT . ■=MONUMENT /- !�' N 9_ 8 •=SPIKE -PECONIC Y0 S, ANY ALTERATIDM OR ADDITION TO THIS SURVEY IS A VIOLATION (631) 7655 - S Q 1) 1797 'CF SECTION 7209 IF THE ICV YORK STATE EDUCATION LAY. EXCEPT AS PER SECTION 7209-SUBDIVISION 2. ALL CERTIFICATIONS P. 0. BOX 909 HEREDS ARE VALID FOR THIS MAP AND COPIES THEREOFONLY 1F 1230 TRA VELER SVMSMAP COPIES BEAR THE IMPRESSED SEAL OF TN£SVRVEYGR SOUTHOLD, N.Y.. 4 —7 D APP 0 ED AS NOTED SSW DATE• B.P. FEE �' BY cd NOTIFY BUILDING DEPARTMENT AT 631 765-1802 8AM TO 4PM FOR THE OCCUPANCY OR FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED USE IS UNLAWFUL FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUMBING 3. INSULATION WITHOUT CERTIFICATE 4. FINAL-CONSTRUCTION MUST OF OCCUPANCY BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS COMPLY WITH ALL CODES OF ELECTRICAL NEW YORK STATE&T WN CODES INSPECTION REQUIRED AS REQUIRED AND C DITIONS OF SOUTHOLD OWN ZBA SOUTHO TOWN PLANNING BOARD SOUTH TOWN TRUSTEES N.Y.S. EG SO OLD HPC D USER'S MANUAL AND INSTALLATION P313 (A,C) Series 10 and 12 SEER Single Package Air Conditioner �u CD O r Read this owner information to become familiar with the capabilities and use of yourappliance. Keep this with literature of other appliances where you have easy access to it in the future. If a problem occurs, check the instructions and follow recommendations given. If these suggestions don't eliminate your problem, call your installing contractor or distributor in your area. INTRODUCTION Most any air conditioner will keep you cool. Our air conditioner was designed to do it efficiently. Efficiency means less cost to you while keeping you comfortable. WHY YOUR AIR CONDITIONER WORKS SO WELL, SO QUIETLY 1. Air is cooled by a large evaporator coil. Moisture is also removed from the air by this same coil. 2. Air is then delivered through the main duct, via registers, into your home. 3. Return air is drawn through the return grille. 4. This air enters the unit, passes through the evaporator coil, is cooled and dehumidi- fled. Then the cycle begins again. SECTION 1. OWNER 3. For best air flow, make sure your return INFORMATION grille is not covered and that the filter is clean. 4. Check the outdoor condenser coil and OPERATING INSTRUCTIONS make sure it is clean and not clogged with To Turn On Air Conditioner grass or leaves. If•your air conditioner still isn't working,call your 1. Set the system switch to "Cool." nearest distributor. '2. Set the thermostat at the temperature level you desire. 3. Your air conditioner should start as soon as SECTION 2. INSTALLER room temperature rises above the setting INFORMATION on the thermostat. To Shut Off Air Conditioner GENERAL- Read the following instructions completely 1. Turn the system switch to "Heat" or"Off." before performing the installation. 2. Turn the thermostat to the desired heating These instructions are for the use of qualified temperature setting. personnel specially trained and experienced in the installation of this type of equipment and BEFORE YOU CALL A SERVICEMAN related system components. Some states re- Check your system at the start of each air quire installation and service personnel to be conditioning season. Make sure it's working licensed. Unqualified individuals should not right, clean or change filters and make any attempt to interpret these instructions or install needed adjustments. this equipment. In addition, follow these simple rules: The single packaged air conditioners are de- l. Never run your system without a filter. If signed for outdoor installation only and can be ,you do,the cooling coils will collect dirt and readily connected into the high static duct may become clogged. system of a home. The only connections 2. Set your thermostat at the comfort level needed for installation are the supply and return you wish -- and then leave it alone. Let it 'ducts, the line voltage, and thermostat wiring. control the operation of the air conditioning system. If you get chilly,turn it up a degree The single package air conditioner is com- at a time until comfort is restored. pletely assembled, factory wired, and factory 3. It takes longer for an air conditioner to cool run tested. The units are ready for easy and your dwelling than it does for your furnace immediate installation. to heat it. So. . . don't turn the unit on and expect a dramatic drop in temperature, at PRE-INSTALLATION CHECK least not right away. If your home is hot and Before any installation is attempted,the cooling humid, the,temperature will drop slowly. load of the area to be conditioned must be 4. Check your filters every 30 days in sum- calculated and a system of the proper capacity mer to see if they are dirty. To keep them selected. It is recommended that the area to be clean, use a mild solution of detergent and conditioned be completely insulated and vapor water on washable types. Replace non washable filters. I sealed. 5. Keep your outdoor condenser coil clean. The installer should comply with all local codes You can hose it down when it gets dirty. and regulations which govern the installation of If your air conditioner isn't working: this type of equipment. Local codes and regu- 1. Make sure the fuses are not blown or that lations take precedence over any recommen- your circuit breakers are on. dations contained in these instructions.Consult 2. See that your thermostat is set at the local building codes and the National Electrical desired temperature and that your system's Code(ANSI Cl)for special installation require- switch is on "Cool." ments. 2 The electrical supply should be checked to determine if adequate power is available. If ICAUTION: there is any question concerning the power supply, contact the local power company. Do not tip the unit on its side. Oil may enter the compressor cylinders and Inspecting Equipment: All units are securely cause starting trouble. If unit has been packed at the time of shipment and, upon set on its,side,restore to upright posi- arrival, should be carefully inspected for dam- tion and do not run for several hours. age. Claims for damage (apparent or con- cealed) should be filed immediately with the Then run unit for a few seconds. Do carrier. this three or four times with five min- utes between runs. INSTALLATION (For Platinum Series ready homes) 3. INSTALL THE RETURN AND SUPPLY AIR FITTINGS ON THE UNIT 1. LOCATE THE 40 AMP BRANCH CIR- The supply and return fittings are shipped in the CUIT DISCONNECT RECEPTACLE AND supply duct. They attach to the unit openings DISCONNECT COVER LOCATED OUT- with a flange and bead arrangement, secured SIDE ON ONE OF THE OUTER WALLS with two sheet metal screws. Note: For ease of OF THE HOME. access, install fitting before positioning unit in final location. Locate the unit within the reach of the Power Cord assembly and branch circuit receptacle. SUPPLY DUCT Position the supply duct collar so the edge ofthe • Create a solid,level position,preferably on a unit openings fit between the flange and the concrete slab or plastic pad(use NORDYNE bead. Overlap the collar ends keeping the small P/N-903897 or equivalent)and slightly above screw holes underneath.Align the holes in the grade level, located where the skirting chan- crimped area and install one screw. nel across top of unit is directly under bottom edge of wall. (See Fig. 1) Tap collar as necessary to ensure engagement • Minimum clearances to obstructions. (See with unit opening and install second screw. Fig. 1) Tighten first screw. 2. UNPACK THE UNIT DUCTING SYSTEM It is recommended that the unit be unpacked at the installation site to minimize damage due to DUCT REQUIREMENTS handling. THE AIR OUTPUT OF THE SYSTEM WILL a. Remove the bands from around the unit. NOT CONDITION THE HOME IF THE AIR IS b. Unfold the top and bottom cap flanges. LOST TO THE OUTSIDE THROUGH LEAKS c. Carefully remove the top cap and tube. 6 ft. 12" 24" Skirting Channel 12"Dia. E 12" Dia. 0 e Supply Air r Supply Air To Main Ducts(2) From Furnace 36" 12" 14"Dia. Figure 1. Minimum Unit Clearances Figure 2. Supply Air Fittings 3 1 IN THE DUCT SYSTEM. ALSO, DUCTS ELECTRICAL CONNECTIONS WHICH ARE COLLAPSED OR RESTRICTED BY FOREIGN OBJECTS WILL PREVENT 1. ELECTRICAL SERVICE ADEQUATE AIR FLOW. HIGH VOLTAGE CONNECTING THE RETURN AND SUPPLY a. An approved branch circuit disconnect AIR FLEXIBLE DUCTS receptacle of adequate size and discon- nect cover per NEC has already been a. Use 12" duct to connect unit to the home installed at the intended location of the unit duct system. (See Fig. 2 and 3) on one of the four exterior walls of the home. b. Use 14" duct to connect unit to furnace. b. Attach the approved Power Cord/Discon- (See Fig. 2 and 3) nect Plug (NORDYNE P/N-903899)to the c. The flexible ducts can be connected to the unit using a strain relief connector(Romex corresponding fittings with the clamps pro- type or equivalent)through the high voltage vided with the ducts. Note: All connections knockout provided. should be leak tight or a loss in cooling c. Extend the power cord leads up into the capacity will result. control panel and connect L1 (Black) and d. The flexible ducts may be cut to the re- L2 (White) directly to the contactor lugs quired length,see instructions packed with provided. (See Fig. 4) duct. Keep all ducts as short and straight d. Ground the air conditioning unit by attach- as possible. Avoid sharp bends. ing the power cord ground wire (Green=w/ e. Ducts may be spliced with sheet metal eyelet)to the unit using the green ground- sleeves-and clamps. ing screw provided in the control panel. f. Once the inner duct is connected to the (See Fig. 4) proper fitting, the insulation and plastic sleeve should be pulled over the connec- LOW VOLTAGE tion and clamped. a. Low voltage wiring from the indoor furnace g. For homes with multiple supply ducts or for and thermostat will be located under the special applications,a Y fitting is available home near the branch circuit receptacle to divide the supply air so it can be ducted and cover. Route the 24V control wires to different areas of the home for more through the low voltage sealing grommet. efficient cooling. Note: The Y fitting should (See Figure 4) be insulated for maximum performance. b. Connect the low voltage control wires to the leads in the low voltage compartment as CONDENSATE DRAIN shown in Figure 4 and 5. A 3/4" condensate drain connection is located 2. OVERCURRENT PROTECTION on the side of the unit below the electrical compartment.Afield supplied condensate drain In general, the best fuse or breaker for any air should be installed. Route the condensate to a conditioner is the smallest size that will permit suitable drainage area. Any connecting tube or the equipment to run under normal use and hose must havethe outlet belowthefitting on the service without nuisance trips. Such a device, unit for proper drainage. sized properly,gives maximum equipment pro- tection. The principal reason for specifying a time delay type is to prevent nuisance trips ZE WARN I N G: when the unit starts. Turn off electrical power before ser- In the event that a fuse does blow or a breaker vicing controls. Severe electrical trips, always determine the reason. Do not shock may result unless power is arbitrarily put in a larger fuse or breaker and do turned off. Unit must be installed in not, in any case, exceed the maximum size compliance with the National Electri- listed on the data label of the unit. cal Code (NEC) and local codes. 4 P313 WITH M1 OR E2 FURNACE INSTALLATION O 0 0 14" Flex Duct 12" Flex Duct SINGLE DUCT APPLICATION O 14" Flex Duct 12" Flex Duct MULTIPLE DUCT APPLICATION Figure 3. Typical Applications 5 3. HEAT-COOL THERMOSTAT OPERATION ❑ Is there free air flow to and from the con- denser? A one foot clearance around the Heat-Cool Thermostat: Your thermostat coil, and six foot clearance above the fan? should be located on an inside wall approxi- mately five feet from the floor away from drafts ❑ Is the wiring correct according to the wiring and doors. Do not locate lamps or other objects diagram and electrical codes? . near the thermostat which could affect'its op- eration or block a free flow of air. ❑ Are all the wiring connections tight?Check the condenser fan to make sure it turns The heat-cool thermostat is equipped with a freely. system HEAT-COOL switch,-which provides a positive means of preventing simultaneous ❑ Is the thermostat wired correctly? Is it operation of the heating and cooling mode. The installed in a proper location? thermostat is also equipped with an AUTO-ON fan switch which allows the home owner to 2. START-UP PROCEDURE operate the indoor blower when air circulation is desired. a. Set the system switch to the OFF position. b. Dial thermostat setting as high as it will go. SYSTEM OPERATION c. Turn on power supply at the circuit breaker. d. Set the system switch to ON or COOL. Set 1. PRE-START CHECK LIST the temperature setting to below room temperature.Verify that the indoor blower, outdoor fan, and compressor are ener- The following check list should be observed gized and the cooling function starts. prior to starting the unit. e. Verify that the discharge air grilles are adjusted and the system is balanced. ❑ Isthe unit level? It should be level or slightly f. Verify that there are no air leaks in the duct slanted toward the drain for proper con- work. densate drainage. g. Verify that the condensate drain is properly installed and that it functions correctly. h. Dial the thermostat higher than room tem- perature. The unit should stop. ® 0 i. If using a combination heating-cooling ther- Lly mostat,set to the HEAT position. Proceed Contactor to check for correct furnace operation. o Lugs j. Verify that the furnace controls and burn- ers or heating elements operate correctly. ® 0 ® k. Instruct the owner on unit operation, filter L2(White) servicing, and proper thermostat opera- -' L1 (Black) tion. o Ground ®,-- , -C (Green) a Low ° Voltage Air Conditioner Connections 0 �0 Furnace Low Voltage ® ® __ Entry Doe, ®High Voltage Entry C BLACK®---- -- - - ® m m -- -"---YELLOW Condensate Drain Figure 4. Power Entry and Hook Up Figure 5. Low Voltage Connections 6 10 SEER - Refrigerant Charging Tables 2 Ton OUTDOOR TEMPERATURE °F 70 75 80 85 1 0 95 100 105 Suct.Presi Die.Press.Dis.Temp.Dis.Press.Dis.Temp.Dis.Press.Dis.Temp.Dis.Press.Dis.Temp.Dis.Press.Dis.Temp.Dis.Press.Dis.Temp. Dis.Press.Dis.Temp.Dis.Press.Dis.Temp. 71 172 151 73 174 156 188 155 75 176 161 190 160 203 159 77 179 165 192 165 206 164 219 163 79 183 167 1 195 169 208 169 221 168 1 235 167 81 199 172 211 172 223 173 237 172 251. , 172 83 214 176 227 176 239 176 253 176 266 176 85 230 180 242 180 255 180 268 .180 282 180 87 234 184 246 184 258 184 270 184 284 183.. 89 249 188 262 188 274 188 _ 286 187 91 265 192 277 192 290 192 93 281 196 293 196 95 297 201 97 2-1/2 Ton OUTDOOR TEMPERATURE °F 70 75 80 85 90 95 100 105 Suct.Pres Dis.Press.Dis.Temp.Dis.Press.Dis.Temp.Dis.Press.Dis.Temp.Dis.Press.Dis.Temp.Dis.Press.Dis.Temp.Dis.Press.Dis.Temp. Dis.Press.Dis.Temp.Dis.Press.Dis.Temp. 69 187 153 71 189 159 203 158 73 191 164 205 163 220 162 75 194 169 208 168 222 167 236 166 77 197 171 210 172 224 171 238 170 252 170 79 214 175 227 175 240 175 254 174 269 174 81 230 179 243 179 257 178 271 178 285 177 83 247 183 260 182 273 182 287 181 301 181 85 250 186 263 186 276 186 289 185 303 185_ 87 267 190 280 190 293 190 305 -189 89 283 194 296 194 309 . 193 91 300 198 313 198 93 316 202 95 *Note:All pressures are listed in psig.and all temperatures in T. —4 -Shaded Boxes indicate -Rated Design Values.Suction Pressure will be lower than design value if indoor air -Discharge temperatures greaterthan charted flooded conditions flow,entering dry bulb,or entering wet bulb temperatures are lowerthan design. values indicate an undercharged system. 00 10 SEER - Refrigerant Charging Tables 3 Ton OUTDOOR TEMPERATURE °F 70 75 80 85 90 95 100 105 Suet.Pres Dis,Press.Dis.Temp.Dis.Press.Dis.Temp.Dis.Press.Dis.Temp.Dis.Press.Dis.Temp.Dis.Press.Dis.Temp.Dis.Press.Dis.Temp. Dis.Press.Dis.Temp.Dis.Press.Dis.Temp. 67 205 167 69 208 172 221 171 71 210 177 223 176 237 175 73 212 182 225 181 1 239 180 252 179 75 216 185 228 185 241 185 254 184 268 183 77 232 188 244 189 256 188 270 187 283 187 79 247 192 259 192 272 192 285 191 299 190 81 263 196 275 196 287 195 301 194 314 .194 83 266 199 278 199 291 199 303 198 316 198 85 282 203 294 203 306 203 318 292 87 297 207 310 207 322 206 89 313 211 325 211 91 329 215 93 3-1/2 Ton OUTDOOR TEMPERATURE(°F) 70 75 80 85 90 95 100 105 Suct Pres Dis.Press.Dis.Temp.Dis.Press.Dis.Temp.Dis.Press.Dis.Temp. Dis.Press.Dis.Temp.Dis.Press.Dis.Temp.Dis.Press.Dis.Temp. Dis.Press.Dis.Temp.Dis.Press.Dis.Temp. 70 197 157 72 199 162 213 162 74 202 168 216 167 229 167 76 203 174 218 172 232 171 246 171 78 207 177 220 177 234 176 248 176 262 175 80 223 180 236 181 250 180 264 180 1 278 180 82 240 184 252 184 266 184 280 184 294 184 84 256 188 269 188 282 188 296 188 316 188 86 259 192 272 192 285 192 298 192 _312. 191 88 276 196 289 196 302 196 314 195. 90 292 200 305 200 318 200 92 308 205 321 205 94 325 209 96 `Note:All pressures are listed in psig.and all temperatures in T. -Shaded Boxes indicate -Rated Design Values.Suction Pressure will be lowerthan design value ifindoor air -Discharge temperatures greaterthan charted flooded conditions flow,entenrigdrybulb,orenteringwetbulbtemperaturesarelowerthandesign. values indicate an undercharged system. 10 SEER - Refrigerant Charging Tables 4 Ton OUTDOOR TEMPERATURE `F 70 75 80 85 90 95 100 105 Suet Pres Dis.Press.Dis.Temp.Dis.Press.1 Dis.Temp.Dis.Press.Dis.Temp.Dis.Press.Dis.Temp.Dis.Press.Dis.Temp. Dis.Press.Dis.Temp.Dis.Press.Dis.Temp.Dis.Press.Dis.Temp. 68 202 162 70 204 168 219 169 72 206 173 221 174 236 175 74 208 180 223 179 238 179 253 181 76 211 1B2 225 184 1 241 184 1 256 185 271 186 78 229 187 243 189 258 190 273 191 288' 192 80 246 192 260 194 275 195 290 196 305 198 82 264 198 278 199 292 200 307 202s 322 203 84 267 201 281 203 295 204 309 206 324 207 86 285 207 299 209 313 210 326 211, 88 302 213 316 214 330 215 90 320 218 334 220 92 337 224 94 5 Ton OUTDOOR TEMPERATURE °F 0 70 75 80 85 90— 95 100 105 Suct.Presi Dis.Press.Dis.Temp. Dis.Press.Dis.Temp.Dis.Press.Dis.Temp. Dis.Press.Dis.Tem . Dis.Press.Dis.Temp.Dis.Press. Dis.Temp. Dis.Press. Dis.Temp. Dis.Press. Dis.Temp. 58 195 166 60 197 171 212 171 62 199 177 214 176 229 176 64 201 184 216 181 231 181 246 180 66 204 186 218 187 234 185 249 185 264 185 68 222 190 236 190 251 190 266 189 1 281 189 0 70 239 194 253 194 268 194 283 193 298 193 72 257 197 271 198 - 285 198 300 197 315 197 74 260 201 274 202 288 202 302 201 317 201 76 278 205 292 206 306 206 319 205 78 295 210 309 210 323 210 80 313 .214 327 214 82 330 219 84 Note:All pressures are listed in psig.and all temperatures in T. cfl -Shaded Boxes indicate Rated Design Values.Suction Pressure will be lowerthan design value ifindoorair -Discharge temperatures greaterthancharted flooded conditions flow,enteringdrybulb,orenteringwetbulbtemperaturesarelowerthandesign. values indicate an undercharged system. 12 SEER - Refrigerant Charging Tables 2 Ton OUTDOOR TEMPERATURE °F 70 75 80 85 90 95 100 105 Suct Pres Dis.Press.Dis.Temp.Dis.Press.Dis.Temp.Dis.Press.Dis.Temp.Dis.Press.Dis.Tern .Dis.Press.Dis.Temp. Dis.Press.Dis.Temp. Dis.Press.Dis.Temp.Dis.Press.Dis.Tem . 72 163 137 74 165 143 178 141 76 167 148 1B0 146 192 145 78 170 153 182r151 194 150 207 14880 173 156 185 196 154 209 153 221 152 82 188 199 158 211 157 223 156 236 155 84 203 162 214 161 225 160 238 159 250 158. 86 217 165 229 164 240 163 252 162 265. 161. ' 88 221 169 232 168 243 167 254 166 267 166 ' 90 236 172 247 171 258 170 269 -169 92 250 176 261 175 273 174 94 265 179 276 178 96 280 183 98 2-1/2 Ton OUTDOOR TEMPERATURE °F) 70 75 80 85 90 95 100 105 Suct Pres Dis.Press.Dis.Temp.Dis.Press.Dis.Temp. Dis.Press.Dis.Temp.Dis.Press.Dis.Temp. Dis.Press.Dis.Temp.Dis.Press.Dis.Temp.Dis.Press,Dis.Temp.Dis.Press.Dis.Temp. 72 168 142 74 171 147 183 147 76 173 152 185 152 198 153 78 175 158 18B 157 200 158 213 159 80 178 160 190 162 202 163 215 163 228 164 82 194 165 205 167 217 168 230 168 243 169 84 209 170 220 172 232 173 245 174 258 175 86 224 176 235 177 247 178 280 179 272 180 88 227 179 239 181 250 182 262 183 274 184 90 242 185 264 186 265 187 276 187_ 92 257 190 269 191 280 192 94 272 196 284 197 96 287 201 98 *Note:All pressures are listed in psig.and all temperatures in T. Shaded Boxes indicate Rated Design Values.Suction Pressure will be lowerthan design value if indoorair -Discharge temperatures greaterthancharted flooded conditions flow,entering dry bulb,orentering wet bulb temperatures are lowerthan design. values indicate an undercharged system. 12 SEER - Refrigerant Charging Tables 3 Ton OUTDOOR TEMPERATURE °F 70 75 80 85 90 95 100 105 Suct.Pres Dis.Press.1 Dis.Temp.Dis.Press.Dis.Temp.Dis.Press.Dis.Temp.Dis.Press.Dis.Temp.Dis.Press.Dis.Temp.Dis.Press.Dis.Temp. Dis.Press.Dis.Temp.Dis.Press.Dis.Temp. 72 175 128 74 177 133 192 135 76 179 139 195 140 210 141 78 180 148 197 145 212 146 227 148 '80 183 151 1 198 152 1 214 151 229 152 244 154 82 201 155 215 157 231 157 246 158 262, 160. 84 219 160 233 162 248 163 264 164 279 US 86 237 165 251 167 266 168 281, 169 296, 170' 88 240 169 255 171 269 172 283 173 296 174 90 258 174 272 176 287 178 300. 178 ._ 92 276 180 290 182 305 183 94 294 186 308 188 96 311 192 98 3-1/2 Ton OUTDOOR TEMPERATURE `F 70 75 80 85 90 95 100 105 Suct.Pres Dis.Press.Dis.Temp.Dis.Press.Dis.Temp.Dis.Press.Dis.Temp. Dis.Press.Dis.Temp.Dis.Press.Dis.Temp.Dis.Press.Dis.Temp. Dis.Press.Dis.Temp.Dis.Press.Dis.Temp. 70 171 152 72 173 157 188 155 74 176 162 191 160 206 158 76 1 179 165 193. 165 208 162 223 160 r 183 168 196 168 210 167 225 165 240 163 200 171 214 171 227 170 242 168 258 166 217 174 231 173 245 172 260 170 275 169 234 177 248 176 262 175 277 173 . 292 172 238 181 251 180 265 179 279 177 294 176 255 184 269 183 282 181 296 179 90 272 187 286 185 300 184 92 289 190 303 188 94 307 193 96 Note:All pressures are listed in psig.and all temperatures in T. —� -Shaded Boxes indicate Rated Design Values.Suction Pressure will be lowerthan design value ifindoorair -Discharge temperatures greaterthancharted flooded conditions flow,entering dry bulb,or entering wet bulb temperatures are lowerthan design. values indicatean undercharged system. 12 SEER - Refrigerant Charging Tables 4 Ton OUTDOORTEMPERATURE T) 70 75 80 85 90 95 100 105 V r' Suct.Pres Dis.Press.Dis.Temp.Dis.Press.Dis.Temp.Dis.Press.Dis.Temp.Dis.Press.Dis.Temp.Dis.Press.Dis.Temp.Dis.Press.Dis.Temp.Dis.Press.Dis.Temp.Dis.Press.Dis.Temp. O OD m 64 178 145 O ME== D 66 181 150 194 151 UI CTI (A 68 183 156 197 156 210 156 � m 70 184 163 199 161 212 161 226 162 r 72 187 166 200 167 215 166 228 166 242 167 = \ 74 204 170 217 171 230 171 244 171 ,258 172 76 220 174 233 175 246 176 260 176 274 177 - 5 m E86 236 179 249 180 262 180 276 ,. 181. 289 . .181' 240 183 253 184 265 184 278 185 291 185, 256 188 269 188 282 189 293 189 m 272 193 285 193 298 194 289 198 301 198 m Z 305 203 m Z Cn_q 0 -�i � 9 D r :Note:All pressures are listed in psig.and all temperatures in T. M P" M -Shaded Boxes indicate -Rated Design Values.Suction Pressure will be lower than design value ifindoor air OC flooded conditions flow,entering dry bulb,or entering wet bulb temperatures are lowerthan design. G -Discharge temperatures greaterthan charted Cl) m O values indicate an undercharged system. Mr0 Z N0 0 J N (n J C7 T CL 7 a C 'N ♦/ 0 O N _ ~ O j_ 7 > >,N C= w CO)CL co a G7 v o v D s O 7 o M m O t Air Air Conditioners ' 0 I RA13 Series t t The new degree of comfort:" Rheem Classic® Series Air Conditioners RA13 Series Efficiencies up to 15 SEER/13 EER �s Nominal Sizes 11/2 to 5 Ton [5.28 to 17.6 kW] Cooling Capacities 17.3 to 60.5 kBTU [5.7 to 17.7 kW] Laren j Proper siring and Installation of equipment Is critical to achieve optimal performance.Split system air conditioners and heat pumps must be matched with appropriate coil components to meet Energy Star. Ask your Can tractor for details orvislt www.energystargov.^ - Composite base pan—dampens sound,captures louver panels, - Diagnostic service window with two-fastener opening— eliminates corrosion and reduces number of fasteners needed provides access to the high and low pressure. - Powder coat paint system—for a long lasting professional finish - External gauge port access—allows easy connection of - Scroll compressor—uses 70%fewer moving parts for higher 'low-loss"gauge ports efficiency and increased reliability - Single-row condenser coil—makes unit lighter and allows - Modern cabinet aesthetics—increased curb appeal with visu- thorough coil cleaning to maintain'but of the box" ally appealing design performance - Curved louver panels—provide ultimate coil protection, - 35%fewer cabinet fasteners and fastener-free base—allow enhance cabinet strength,and increased cabinet rigidity for faster access to internal components and hassle-free e Optimized fan orifice—optimizes airflow and reduces unit panel removal sound e Service trays—hold fasteners or caps during service calls - Rust resistant screws—confirmed through 1500-hour salt - QR code—provides technical information on demand for spray testing faster service calls e PlusOneTm Expanded Valve Space—3'-4 -5' service valve @ Fan motor harness with extra long wires allows unit top to be space—provides a minimum working area of 27-square removed without disconnecting fan wire. inches for easier access e PlusOneTM Triple Service Access—15"wide,industry lead- ing corner service access—makes repairs easier and faster. The two fastener removable corner allows optimal access to internal unit components.Individual louver panels come out once fastener is removed,for faster coil cleaning and easier cabinet reassembly INTEGRATED HOME COMFORT FORM NO.All-221 REV.8 Air Table of Contents —7i RA13 Series TABLE OF CONTENTS StandardFeature......................................................................................................3 AvailableSKUs ........................................................................................................3 Features&Benefits Model Number Identification ................................................................................6-7 General Data/Electrical Data....................................................................................8 Accessories ............................................................................................................9 WeightedSound Power............................................................................................9 UnitDimensions......................................................................................................10 Clearances..............................................................................................................11 WiringDiagrams ....................................................................................................12 Application Guidelines............................................................................................12 Refrigerant Line Size Information......................................................................13-16 Performance Data ..................................................................................................17 GuideSpecifications ..............................................................................................18 LimitedWarranty....................................................................................................19 COMFORTINTEGRATED HOME Air I Standard Feature/Available SKUs 0 RA13 Series Standard Feature Table STANDARD FEATURES Feature 18 24 30 36 42 48 60 R-410a Refrigerant J ✓ J J ✓ ✓ J Maximum SEER 14.5 14.0 15.0 15.0 14.0 13.5 13.5 Maximum EER 12.5 12.0 13.0 13.0 12.0 11.5 11.5 Scroll Compressor J J ✓ J J J J Field Installed Filter Drier ✓ J ✓ J J J J Front Seating Service Valves ✓ J J J J J ✓ Internal Pressure Relief Valve J J J J J J J Internal Thermal Overload J J J J ✓ J J Long Line capability J J J J J J J Low Ambient capability with Kit J ✓ J J J J J 3-4-5 Expanded Valve Space J ✓ J ✓ J J ✓ Composite Basepan ✓ ✓ ✓ J ✓ J J 2 Screw Control Box Access J J J J ✓ ✓ J 15"Access to Internal Components J J J ✓ ✓ ✓ J Quick release louver panel design J J ✓ ✓ ✓ J J No fasteners to remove along bottom J J ✓ J J J J Optimized Venturi Airflow J J ✓ J J ✓ ✓ Single row condenser coil J ✓ ✓ J J J ✓ Powder coated paint J J ✓ J J J J Rust resistant screws ✓ J ✓ J J ✓ ✓ QR code . ✓ J ✓ J J ✓ J External gauge ports ✓ J ✓ J ✓ J ✓ Service trays J J J ✓ J ✓ J J=Standard Available SKUs Available Models Description RA1318AJl NA Classic®Series 1 1/2 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1318AJl NB Classic®Series 1 1/2 ton 13 SEER Single-Stage Air Con ditioner-208/230/1/60 RA1324BJl NA Classic®Series 2 tan 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1324BJl NB Classic®Series 2 ton 13 SEER Single-Stage Air Con ditioner-208/230/1/60 RA1330AJl NA Classic®Series 21/2 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1330AJl NB Classic®Series 21/2 tan 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1336AC1NB Classic®Series 3 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1336ADl NB Classic®Series 3 ton 13 SEER Single-Stage Air Conditioner-460/3/60 RA1336AJl NA Classic®Series 3 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1336AJl NB Classic®Series 3 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1342ACl NB Classic®Series 31/2 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1342AD1 NB Classic®Series 31/2 ton 13 SEER Single-Stage Air Conditioner-460/3/60 RA1342AJl NA Classic®Series 31/2 ton 13 SEER Single-Stage Air Conditioner-208/230/l/60 RA1342AJl NB Classic®Series 31/2 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1348ACl NB Classic®Series 4 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1348ADl NB Classic®Series 4 ton 13 SEER Single-Stage Air Conditioner-460/3/60 RA1348AJl NA Classic®Series 4 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1348AJl NB Classic®Series 4 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1360ACl NB Classic®Series 5 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1360ADl NB Classic®Series 5 ton 13 SEER Single-Stage Air Conditioner-460/3/60 RA1360AJl NA Classic®Series 5 ton 13 SEER Single-Stage Air Con d itione r-208/230/l/60 RA1360AJ1 NB Classic®Series 5 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 INTEGRATED . COMFORT Air IFeatures&Benefits RA13 Series Introduction to RA13 Air Conditioner The RA13 is our 13 SEER air conditioner and is part of the Rheem air conditioner product line that extends from 13 to 20 SEER.This highly featured and reliable air conditioner is 12,.' _ designed for years of reliable,efficient operation when matched I,II with Rheem indoor aluminum evaporator coils and furnaces or air handler units with aluminum evaporators. Our unique composite base(0)reduces sound emission,elimi- nates rattles,significantly reduces fasteners,eliminates corro- If in the rare event,greater access is needed to internal compo- sion and has integrated brass compressor attachment inserts nents,such as the compressor,the entire corner of the unit can (❑2). Furthermore it has incorporated into the design,water be removed along with the top cover assembly to have unprece- management features,means for hand placement-(❑3 )for unit dented access to interior of the unit(ia).Extra wire length is maneuvering,screw trays(®)and inserts for lifting off unit incorporated into each outdoor fan and compressor so top pad.(❑e ) cover and control panel can be positioned next to the unit.With minimal effort the plug can be removed from the compressor l and the outdoor fan wires can be removed from the capacitor to, —" allow even more uncluttered access to the interior of the unit �j Outdoor coil heights range from as short as 22"to 28",aiding 1���I access to the compressor.Disassembly to this degree and com- plete reassembly only takes a first time service technician less a 14P than 10 minutes. ❑s 9— . . 18 1W Service Valves(©)are rigidly mounted in the composite base - with 3"between suction and discharge valves,4"clearance below service valves and a minimum of 5"above the service ! valves,creating industry leading installation ease.The minimum a 27 square-inches around the service valves allows ample room to remove service valve Schrader prior to brazing,plenty of clear- ---- ance for easy brazing of the suction and discharge lines to ser- vice valve outlets,easy access and hookup of low loss refriger- All units utilize strong formed louver panels which provide indus- ant gauges(Di ),and access to the service valve caps for . try leading coil protection. Louver removal for coil cleaning is opening. For applications with long-line lengths up to 250 feet accomplished by removing one screw and lifting the panel out of total equivalent length,up to 200 feet condenser above evapora- the composite base pan.(n)All RA13 units utilize single row tor,or up to 80 feet evaporator above condenser,the long-line coils(ie)making cleaning easy and complete,restoring the instructions in the installation manual should be followed. performance of the air conditioner back to out of the box perfor- mance levels year after year. Controls are accessed from the corner of the unit by removing only two fasteners from the control access cover,revealing the The outdoor fan motor has sleeve bearings and is inherently industry's largest 15"wide and 14"tall control area(®).With all protected.The motor is totally enclosed for maximum protection this room in the control area the high voltage electrical whip(Fk]) from weather,dust and corrosion.Access to the outdoor fan is can easily be inserted through the right size opening in the bot- made by removing four fasteners from the fan grille.The outdoor tom of the control area.Routing it leads directly to contractor fan can be removed from the fan grille by removing 4 fasteners lugs for connection.The low voltage control wires(io)are easily in the rare case outdoor fan motor fails. connected to units low voltage wiring.If contactor or capacitor (11)needs to be replaced there is more than adequate space to Each cabinet has optimized composite(is)fan orifice assuring make the repair.Furthermore,if high pressure and low pressure efficient and quiet airflow. model was not purchased but is desired to be installed in the field,the service window(i2)can be removed by removing two screws,to access the high and low side Schrader fittings for easy is field installation.The entire corner can be removed providing ultimate access to install the high and low pressure switch.(13) ' 1 COMFORT4 INTEGRATED HOME Features✓£Benefits a Air I RA13 Series The entire cabinet has powder post paint(20)achieving 1000 Optional Accessories hour salt spray rating,allowing-the cabinet to retain its aesthetics (Refer to accessory chart for model#) throughout its life. Compressor Crankcase Heater - Protects against refrigerant migration that can occur during low 20 ambient operation Compressor Sound Cover 23 •Reinforced vinyl compressor cover containing a 1'/2 inch thick E k bait of fiberglass insulation 21 •Open edges are sealed with a one-inch wide hook and loop fastening tape . Scroll compressors with standard internal pressure relief and Compressor Hard Start Kit internal thermal overload are used on all capacities assuring •Single-phase units are equipped with a PSC compressor longevity of high efficient and quiet operation for the life of the motor,this type of motor normally does not need a potential product. relay and start capacitor Each unit is shipped with filter drier for field installation and will •Kit may be required to increase the compressor starting trap any moisture or dirt that could contaminate the refrigerant torque,in conditions such as low voltage system. Low Ambient Kit •Air conditioners operate satisfactorily in the cooling mode down to 55°F outdoor air temperature without any additional controls •This Kit can be added in the field enabling unit to operate properly down to 00 in the cooling mode •Crankcase heater and freezestat should be installed on com- pressors equipped with a low ambient kit All cabinets have industry leading structural strength due to the 3"/6"/12" composite base pan(21),interlocking corner post(❑2z),formed a Gray high density polyethylene feet are available to raise unit curved louver panels(®)and drawn top cover(2a)making it off of mounting surface away from moisture the most durable cabinet on the market today. Low Pressure Each RA13 capacity has undergone rigorous psychometric test- •Can be added in field enabling the unit to shut off compressor ing to assure performance ratings of capacity,SEER and EER on loss of charge per AHRI Standard 210/240 rating conditions.Also NOTE:Unit can be purchased with high and low pressure each unit bears the UL mark and each unit is certified ut „ ) installed at factory.(Refer to SKU list) to UL 1995 safety standards. ucrm High Pressure Each unit has undergone specific strain and modal testing to •Can be added in field enabling unit to shut off compressor if assure tubing(9)is outside the units natural frequency and that unit loses outdoor fan operation. the suction and discharge lines connected to the compressor Withstand any starting,steady state operation or shut down NOTE:Unit can be purchased with high and low pressure forces imposed by the compressor. Installed at factory.(Refer to SKU list) All units have been sound tested in sound chamber to AHRI 270 Decorative Top _ rating conditions,and A-weighted Sound Power Level tables •Can be installed on fan grille produced,assuring units have acceptable noise qualities(see page 9).Each unit has been ran in cooling operation at 95°F and 820F and sound ratings for the RA13 range from as low as 73 dBA to 79 dBA. All units have been ship tested to assure units meet stringent "over the road"shipping conditions. As manufactured all units in the RA13 family have cooling capa- bility to 55 OF.Addition of low ambient control will allow the unit to operate down to 0°F.Factory testing is performed on each unit.All component parts meet well defined specification and continually go through receiving inspections.Each component installed on a unit is scanned,assuring correct component uti- lization for a given unit capacity and voltage.All condenser coils are leak tested with pressurization test to 550#'s and once installed and assembled,each units'complete refrigerant system is helium leak tested.All units are fully charged from the factory for up to 15 feet of piping.All units are factory run tested. The RA13 has a 10-year conditional compressor and parts war- ranty(registration required). COMFORTINTEGRATED HOME Air Conditioners* JL6 R A 13 24 A . J 1 N A D Brand Product SEER Capacity Major Series* Voltage Type Controls Minor Series** Option Category BTU/HR Code y m - Rheem A-Air Conditioners 13-13 SEER 18-18,000 [5.28 kW] A-1st Design J-1 ph,208-230/60 1 -Single-stage N-Non-Communicating A-1st Design N/A F 24-24,000 [7.03 kW] B-2nd Design C-3ph,208-230/60 B-2nd Design 30-30,000 [8.79 kW] D-3ph,460/60 FX 36-36,000[10.55 kW] a 42-42,000 [12.31 kW] w 48-48,000 [14.07 kW] 0. 60-60,000 [17.58 kW] *See page 3 for available SKU's. Heat Pumps (For R. R P 14 24 A J 1 N A Brand Product SEER Capacity Major Series* Voltage Type Controls Minor Series** Option Category BTU/HR Code Rheem P-Heat Pump 13-13 SEER 18-18,000 [5.28 kW] A-1 st Design J-1 ph,208-230/60 1-Single-stage C-Communicating A-1 st Design N/A 14-14 SEER 24-24,000 [7.03 kW] C-3ph,208-230/60 2-Two-stage N-Non-Communicating • 15-15 SEER 30-30,000 [8.79 kW] D-3ph,460/60 - V-Inverter 17-17 SEER 36-36,000[10.55 kW] P-Piston 20-20 SEER 42-42,000[12.31 kW] • 48-48,000[14.07 kW] 60-60,000[17.58 kW] Furnace COUS (For Reference)" R C F 24 17 S T A M C A Brand Product Type Capacity Width Efficiency Metering Major Orientation Casing Minor Series** Option Category BTU/HR Device Series* Code Rheem C-Evap Coil F-Furn Coil 24-24,000 [7.03 kW] 14-14' S-Standard Eff. T-TXV A-1 st Design M-Multipoise C-Cased A-1 st Design N/A H-Air-Handler 36-36,000[10.55 kW] 17-17.5° M-Mid Eff. E-EEV V-Vertical only/ U-Uncased Coil 48-48,000[14.07 kW] 21-21° H-High Eff. P-Piston convertible 60-60,000[17.58 kW] 24-24.5° H-Ded. Horizontal only **Model number to's are for reference only.See available SKU page of applicable spec sheet for table of available SKU's for a specific model. [ ]Designates Metric Conversions 90%+ AFUE Gas Furnaces (For Reference)** R 96 V A 70 2 3 17 M S A Brand Series Motor Major Rev Input Stages Air Flow Cabinet Configuration Nox Minor Rev BTU/HR Width Rheem 90-90 AFUE V-Variable speed A-1 st Design 040- 42,000 112.31 kW] 1 -Single-stage 3-up to 3 ton 14-14" M-Multi X-Low Nox A-1st Design 92-92 AFUE T•-Constant 060- 56,000[16.41 kW] 2 -Two-stage 5-31/2 up to 5 ton 17-17.5" S-Standard 95-95 AFUE Torque 070- 70,000 120.51 kW] M-Modulating 21 -21" 96-96 AFUE (X-1 3) 085- 84,000[24.62 kW] 24-24.5" 97-97 AFUE P-PSC 100- 98,000 128.72 kW] 115-112,000[32.82 kW] 80%AFUE Gas Furnaces (For Reference)" R 80 2 V A 075 3 17 M S A Brand Series Stages Motor Major Rev Input Air Flow Cabinet Configuration Nox Minor Rev BTU/HR Width Rheem 80-80+AFUE 1 -Single-stage V-Variable speed A-1 st Design 050- 50,000(15 kW] 3-up to 3 ton 14-14" M-Multi X-Low Nox A-1 st Design 2 -Two-stage T-Constant Torque(X-1 3) 075- 75,000[22 kW] 4-21/2 to 4 ton 17-17.5" D -Down S-Standard P-PSG premium 100-100,000[29 kW] 5-31/2 up to 5 ton 21-21' Z -Down& S-PSC standard 125-125,000[37 kW] 24-24.5" zero clearance 150-150,000[44 kW] down flow Air Handlers (For R. R H 1 T 36 17 S T A N A A 000 • Brand Product Stages of Motor Type Capacity Width Coil Size Metering Major Controls Voltage Minor Factory Heat Option Category Airflow BTU/HR Device Series* Series** Cap Cade • Rheem H-Air 1-Single-Stage V-Variable 24-24,000 [7.03 kW] 14-14" S-Standard T-TEV A-1st Design C-Communicating A-1 ph,115/60 A-1 st Design 00-no *TBD Handler 2-Two-Stage Speed 36-36,000[10.55 kW] 17-17.5" Eff. E-EEV N-Non-comm J-1 ph,208-240/60 factory heat M-Modulating T-Constant 48-48,000[14.07 kW] 21-21" M-Mid Eff. P-Piston D-3ph,480/60 with option Torque 60-60,000[17.58 kW] 24-24.5" H-High Eff. code P-PSC **Model number ID's are for reference only.See available SKU page of applicable spec sheet for table of available SKU's for a specific model. [ ]Designates Metric Conversions JL6 2 0 0 m m m Z c m 3 N Q N FL m 0 0 m 0 Air I General Data/Electrical Data "a RA13 Series Physical Data PHYSICAL DATA Model No. RA1318 RA1324 RA1330 RA1336 RA1342 RA1348 RA1360 Nominal Tonnage 1.5 2.0 2.5 3.0 3.5 4.0 5.0 Valve Connections Liquid Line O.D.-in. 3/8 3/8 3/8 3/8 3/8 3/8 318 Suction Line O.D.-in. 3/4 3/4 3/4 3/4 7/8 7/8 7/8 Refrigerant(R410A)furnished oz.11 54 60 72 86 105 106 148 Compressor Type Scroll Outdoor Coil Net face area-Outer Coil 5.9 9.1 9.1 12.1 14.2 14.8 18.8 Net face area-Inner Coil - - - - - - - Tube diameter-in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Number of rows 1 1 1 1 1 1 1 Fins per inch 22 18 22 22 22 22 22 Outdoor Fan Diameter-in. 20 20 20 20 20 24 26 Number of blades 2 2 3 3 2 3 2 Motor hp 1/8 1/8 1/4 1/4 1/8 1/6 1/5 CFM 2040 2325 2795 2900 2465 4145 3870 RPM 1075 1075 1075 1075 1075 850 820 watts 144 137 189 186 176 279 235 Shipping weight-lbs. 127 1 142 1 163 164 195 202 1 235 Operating weight-lbs. 120 1 135 1 156 157 188 1 195 228 Electrical Data Line Voltage Data(Volts-Phase-Hz) 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 Maximum overcurrent protection(amps)' 20 25 30 35 40 50 60 Minimum circuit ampacity3 13 15 18 23 24 29 35 Compressor Rated load amps 9.7 11.2 12.8 16.7 17.9 1 21.8 26.4 Locked rotor amps 48 60.8 64 83.9 112 1 117 134 Condenser Fan Motor Full load amps 0.7 0.7 1.3 1.3 0.7 1 1.2 Locked rotor amps 1.3 1.3 2.5 2.6 1.3 2.2 2.0 Line Voltage Data (Volts-Phase-Hz) - - - 208/230-3-60 208/230-3-60 208/230-3-60 208/230-3-60 Maximum overcurrent protection(amps)2 - - - 20 30 30 35 Minimum circuit ampacity3 - - - 15 18 19 22 Compressor Rated load amps - - - 10.4 13.2 13.7 16 Locked rotor amps - - - 73 88 83.1 110 Condenser Fan Motor Full load amps - - - 1.3 0.7 -1 1.3 Locked rotor amps - - - 2.6 1.3 2.2 2.0 Line Voltage Data (Volts-Phase-Hz) - - - 480-3-60 480-3-60 480-3-60 480-3-60 Maximum overcurrent protection(amps)' - - - 15 15 15 15 Minimum circuit ampacity3 - - - 8 8 9 11 Compressor Rated load amps - - - 5.8 6.0 1 6.2 1 7.8 Lacked rotor amps - - - 38 44 1 41 52 Condenser Fan Motor Full load amps - - - .6 .3 1 .6 .6 Locked rotor amps - - - 2.5 .9 1 1.6 1.1 'Refrigerant charge sufficient for 15 ft.length of refrigerant lines.For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required. 2HACR type circuit breaker of fuse. 3Refer to National Electrical Code manual to determine wire,fuse and disconnect size requirements. 8 INTEGRATED • COMFORT Air Accessories/Weighted Sound Power �i RA13 Series Accessories Model No. RA1318 RA1324 RA1330 RA1336 RA1342 RA1348 RA1360 Compressor crankcase heater' 44-17402-44 44-17402-44 44-17402-44 44-17402-44 44-17402-45 44-17402-45 44-17402-45 Low ambient control RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 Compressor sound cover 68-23427-26 68-23427-26 68-23427-26 68-23427-26 68-23427-25 68-23427-25 68-23427-25 Compressor hard start kit SK-Al SK-Al SK-Al SK-Al SK-Al SK-Al SK-All Compressor time delay RXMD-B01 RXMD-B01 RXMD-801 RXMD-B01 RXMD-B01 RXMD-B01 RXMD-B01 Low pressure control RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 High pressure control RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 Liquid Line Solenoid Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC (24 VAC,50/60 Hz) Solenoid Coil 61-AM024V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V Liquid Line Solenoid Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC (120/240 VAC,50/60 Hz) Solenoid Coil 61-AMG120/240V 61-AMG120/240V 61-AMG1201240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG1201240V Top Cap w/Label 1 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 'Crankcase Heater recommended with Low Ambient Kit Weighted Sound Power Level (dBA) RA13 Sound Power Level Full Octave Linear Sound Power Level dB-Center Frequency-Hz Model Sound Power Level[dB(A)l 125 250 500 1000 2000 4000 8000 RA1318 72.0 51.7 58.3 61.5 61.1 57.0 54.0 47.0 RA1324 75.0 55.4 60.3 64.7 66.4 62.6 58.0 52.4 RA1330 78.0 51.4 67.1 67.5 68.2 65.5 59.8 53.6 RA1336 77.0 55.1 66.1 66.9 68.2 64.6 60.7 55.6 RA1342 73.0 48.9 56.1 62.9 62.2 61.1 55.2 50.2 RA1348 76.0 51.4 59.6 65.2 65.9 64.3 58.5 53.7 RA1360 78.0 51.7 60.9 66.9 70.4 63.5 57.4 53.8 NOTE:Tested in accordance with AHRI Standard 270-08(not listed in AHRO INTEGRATED . COMFORT Air I Unit Dimensions a RA13 Series Unit Dimensions. OPERATING SHIPPING MODEL H(Height) L(Length) W(Width) H(Height) L(Length) W(Width) NO. INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm RA1318 27 685 29.75 755 29.75 755 28.75 730 32.38 822 32.38 822 RA1324 25 635 29.75 755 29.75 755 26.75 679 32.38 822 32.38 822 RA1330 25 635 29.75 755 29.75 755 26.75 679 32.38 822 32.38 822 RA1336 27 685 29.75 755 29.75 755 28.75 730 32.38 822 32.38 822 RA1342 31 787 29.75 755 29.75 755 32.75 831 32.38 822 32.38 822 RA1348 27 685 33.75 857 33.75 857 28.75 730 36.38 924 36.38 924 RA1360 31 787 35.75 908 35.75 908 32.75 831 38.38 974 38.38 974 ALLOW 60"[1524 mm] OF CLEARANCE A R W 5 C H A L R G E H SERVICE PANELS/ INLET CONNECTIONS/HIGH&LOW VOLTAGE ACCESS ALLOW 24"[610 mm]OF CLEARANCE AIR INLET LOUVERS ALLOW 6"[152 mm]MIN.OF CLEARANCE ALL SIDES 12"[305 mm]RECOMMENDED ~ [ ]Designates Metric Conversions ST A1226-02-00 INTEGRATED10 HOME COMFORT CLEARANCES WALL WALL 611 152.4 24" (609.6) Service 24" 1 T 12" D (609.6) (304.8) (304.8) Service 6" (152.4) 6" (152.4) 12„ (304.8) WALL • 24" 24" 24" (609.6) (609.6) (609.6) Service Service Service 18" 24" 24" (457.2) (609.6) (609.6) 24" recommended 24" recommended 9" minimum 9" minimum JL6 NOTE: NUMBERS IN ()= mm n IMPORTANT:When Installing multiple units in an alcove,roof well or partially enclosed area,ensure there is adequate ventilation to prevent re-circulation of discharge air. n ST-A1225-01-00 m N w m ci . m ra N N Air I Wiring Diagram/Application Guidelines 0 RA13 Series Control Wiring FIGURE 2 *IF MAXIMUM OUTLET TEMPERATURE RISE IS DESIRED,IT IS RECOMMENDED THAT CONTROL WIRING FOR GAS OR OIL FURNACE W1(W/BK)AND W2(W/BL)BE JUMPERED TOGETHER. TYPICAL THERMOSTAT TYPICAL THERMOSTAT FOR TYPICAL GAS OR OIL HEAT SUBBASE FOR TYPICAL ELECTRIC HEAT SUBBASE OY © © OO : Y G # A BR-BROWN WIRE YL-YELLOW WIRE BR-BROWN WIRE X-WIRE CONNECTION R-RED WIRE YL-YELLOW WIRE W/BK-WHITE WIRE WITH BLACK STRIPE G/BK-GREEN WIRE WITH BLACK STRIPE PU-PURPLE WIRE(NOT USED) X-WIRE CONNECTION TYPICAL GAS OR TYPICAL ELECTRIC HEAT OIL FURNACE LOW VOLTAGE JUNCTION BOX ' * W/BL ONDENSING R TYPICAL CONDENSING Fl TYPICAL C UNIT UNIT WISK GBK G yL Y YL YL BR - � BR BR PU Application Guidelines 1. Intended for outdoor installation with free air inlet and outlet.Outdoor fan external,static pressure available is less than 0.01 -in.wc. 2. Minimum outdoor operation air temperature for cooling mode without low-ambient operation accessory is 55OF(12.80C). I 3.Maximum outdoor operating air temperature is 125T(51.7°C). 4. For reliable operation,unit should be level in all horizontal planes. 5.Use only copper wire for electric connections at unit.Aluminum and clad aluminum are not acceptable for the type of connector provided. 6.Do not apply capillary tube indoor coils to these units. 7.Factory-supplied filter drier must be installed. INTEGRATED HOME COMFORT Refrigerant Line Size Information 13-16 SEER Single-Stage Air-Conditioners Apply Long Line Equivalent Length(Feet) Guidelines if Linear Line Allowable Allowable Length Exceeds Those Unit Size Liquid Line Suction Line <25 26-50 51-75 76-100 101-125 126-150 151-175 176-200 201-225 226-250 Size Size Shown Below (Feet) (-)A13 A/B Maximum Vertical Rise(Outdoor Unit Below Indoor Unit)'/Capacity Multiplier 1/4" 5/8" N/A 25/1.00 50/0.99 62/0.98 43/0.98 24/0.97 5/0.97 "-NR NR,.; MR' NR ` 5/16° 5/8" N/A 25/1.00 50/0.99 75/0.98.- 98/0.98 93/0.97 88/0.97 83/0.96 78-/0.96 73/0.95 6810.94 1.5 Ton 3/8" 5/8' 178 25/1.00 50/0.99 75/0.98 100/0.98 10010.97 100/0.97 100/,0.96. . 10010.96 100/0.95- 100/0.94 SEE 1/4 3/4 N/A 25/1.00 50/1.00 62/0.99 43/0.99 24/0.99 5/0.99 'MR NR -,NR -,.NR- NO ' -NOTE 3 ' ' 5/16" 3/4-* N/A 25/1.00 50/1.00 75/0.99 98/0.99 93/0.99 88/0.99 83/0.99 78/0.98 73/0.98 68/0.98 3/8° 3/4°** 178 25/1,00 50/1.00 75/1.00 100/0.99 100/0.99 100/0.99 100/0.99 100/0.98 100/0.98 100/0.98 1/4" 5/8' N/A 25/0.99 50/0.98 21/0.97 MR -MR i ' A -NR -----'MR -NH MR 5/16" 5/8" 213 25/0.99 50/0.98 75/0.97 87/0.96 77/,0.95 69./0.94 61./0,93 53/0:92 4510.91 37/0'.90 2 Ton 3/8" 5/8" 142 25/0.99 50/0.98 75/0.97 100/0.96 10010.95 100/0.94 98/0.93. 95/0.92 92/0.91 89/0.90 - - 1/4° 3/4" N/A. 25/1.00 50/1.00 21/0.99 NR' .' MR NR "vNR,.. MR: `NR: MR 5/16' 3/4" 213 25/1.00 50/1.00 75/0.99 87/0.99 77/0.98 69/0.98 61/0.98 53/0.97 45/0.97 , -37/0.96 .' 3/8" 3/4' 142 25/1.00 50/1.00 75/0.99 100/0.99 100/0.98 100/0.98 9810.98 9510.97 93/0.97 90/0.96' 5/16' 5/8' MIA 25/0.99 50/0.98 75/0.96 70/_0.94 5910.93 48/0.91 36/0 90 NR .; NR` '=NR. 3/8" 5/8' 142 25/0.99 50/0.98 7510.96 1007 0.94 98/0.93 94/.0.91 9010.90 '"a, NR �'' NR-i '_-MR-, 2.5 Ton 5/16° 3/4° 213 25/1.00 50/0.99 75/0.99 70/0.98 59/0.98 48/0.97 _ 36 10.96 25,/0.96. 13/0.95 'MR 3/8' 3/4" 142 25/1.00 50/0.99 75/0.99 100/0.98 98/0.98 94/0.97 90/0.96 86.10.96 82/0.95 .' 78/0.95 5/16" 5/8" N/A 25/0.99 50/0.97 66 7 6.94 49/0.92 3210.90 .NR NR MR- : NR MR' 3/8" 5/8" 108 25/0.99 50/0.97 75/0.94 95/0.92 .89/0.90 NR NR x x MR-' :','NR > 'MR 5/16" 3/4" N/A- 25/1.00 50/0.99 66/0.98 49/0.98 32/0.97 15/0.96 A ,NR ' `NR- MR • 3 Ton 3/8" 3/4" 108 25/1.00 50/0.99 75/0.98 95/0.98 89/0.97 84/0.96 78110.95 72/0.94 67/0.93. 61/0.93 1/2" 3/4" 54- 25/1.00 50/0.99 75/0.98 , 100/0.98 100/0.97 100/0.96 100/0.95. 100/0.94 100./.0.93,. 100/0.93 5/16" 7/8" N/A. 25/1.00 50/1.00 66/1.00 49/0.99 32/0.99 15/0.99 MR NR e, �NR. MR 3/8" 7/8" .108 25/1.00 50/1.00 75/1.00 95/0.99 89/0.99 84/0.99 78/0.98 72/0.98 67/0.98 61/0.97 1/2' 7/8' 54 25/1.00 50/1.00 75/1.00 100/0.99 100/0.99 100/0.99 100/0.98 100/0.98 100/0.98 100/0.97 3/8" 3/4" 150 25/0.99 50/0.98 75/0.97 8810.96 80[0.95 72/0.'94 65/0.92 57:7 0.91 49/.0.90 _';NR J�� 3.5 Ton 1/2" 3/4" 75 25/0.99 50/0.98 75/0.97 100/0.96 . 10010..95 100/0.94 100/0.92 100/0.91 100/0:90 NR 3/8' 7/8' 150 25/1.00 50/1.00 75/0.99 88/0.99 80/0.99 72/0.98 65/0.97 57/0.97 49/0.96 42/0.96 ' 1/2' 7/8" 75 25/1.00 50/1.00 75/0.99 100/0.99 100/0.99 100/0.98 100/0.97 100/0.97 1.00/.0.'96 100/0.96 m NOTES: w 1)Do not exceed 200 ft linear line length. y CD 2) 'Do not exceed 100 ft vertical separation if outdoor unit is above indoor unit. m• 3)'"3/4'suction line should only be used for 1.5 tan systems if outdoor unit is below or at same level as indoor to assure proper oil return. H C 4)Always use the smallest liquid line allowable to minimize refrigerant charge. 'm 5)Applications shaded in light gray Indicate capacity multipliers between 0.90 and 0.96 which are not recommended,but are allowed. 6)Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop. li 3 E w 0 Refrigerant Line Size Information (con't.) JL6 13-16 SEER Single-Stage Air-Conditioners y Apply Long Line Equivalent Length(Feet) Allowable . Allowable Guidelines it Linear Line CD Length Exceeds Those Et Unit Size Liquid Line Suction Line. Shown Below (Feet) <25 26-50 51-75 76-100 101-125 126-150 151-175 176-200 201-225 226-250 y Size Size CD `(-)A73 A/B Maximum Vertical Rise(Outdoor Unit Below Indoor Unit)*/Capacity Multiplier y 3/8, 3/4" .148 25/0.99 50/0.98 75 10,96 77/0.'95 67/'0.93 57/0.92 4V1.91' NR ! .NR'` AR in n 1/2' 3/4° 74 25/0.99 50/0.98 75/0.96: 100/0.95 100/0.93 100/.0.92 100./0 91 NR "° NR NR: ; - 4 Ton 3/8' 7/8° '148 25/1.00 50/0.99 75/0.99 77/0.98 67/0.97 57/0.97 ,46 P,006. 36/0 96 . 26/0.05 15 Er/0.95 E 1/2' 7/8" ~ 14 25/1.00 50/0.99 75/0.99 100/0.98 100/0.97 100/0.97 160/0.96 1001.0.96 . 99/0.95 97/0.95 ! 3/8' 3/4" 78- 25/0.99 50/0.97 75/.0.94 61/0.92 46/0.90 NR`. .NR NA ,'l w NA AR -W. .,a>, 1/2' 3/4" 39 . 25/0.99 50/0.97 75/0.94 .100/0 92 •10010 90' " � NR �; d;NRx�°,�x°°, NR 3/8' 7/8" 78_ 25/1.00 50/0.99 75/0.98 61/0.97 467:0:96 3210;95 18%0 94 ' :" NR NR,;: ! NR 5 Ton 1/2' 7/8' 39' 25/1.00 50/0.99 75/0.98 100/0.97 100/0.96 .: 100/0.95, 97/0.94_ -951,0.94 92/0:93 89/0.92' ' 3!8° 1-1/8" " 78 25/1.01 50/1.01 75/1.00 61/1.00" 46/0.99 32/0.99 18/0 99 NRNR `'NR 1/2' 1 1/8" A 25/1.01 50/1.01 75%1.00 100/1.00 100/0.99 100/0.99 97/0.99 95!0.99 92/0.99 89/0.98 NOTES 1)Do not exceed 2001t linear line length. 2) *Do not exceed 100It vertical separation if outdoor unit is above indoor unit 3)**3/4'suction line should only be used for 1.5 ton systems if outdoor unit Is below or at same level as Indoor to assure proper oil return. 4)Always use the smallest liquid line allowable to minimize refrigerant charge. 5)Applications shaded in light gray Indicate capacity multipliers between 0.90 and 0.96 which are not recommended,but are allowed. 6)Applications shaded In dark gray are not recommended due to excessive liquid or suction pressure drop. aw Refrigerant Line Size Information 13-16 SEER Single-Stage Air-Conditioners Apply Long Line Equivalent Length(Meters) - Allowable Allowable Guidelines it Linear Line Liquid Line Suction Line Length Exceeds Those Unit Size Size Size Shown Below (Meters) <8 8 15 16 23 24 30 31 38 39 46 47-53 54-61 62-69 70 76 mm[in.] mm[in.] jiAl&A/B Maximum Vertical Rise(Outdoor Unit Below Indoor Unit)*/Capacity Multiplier 6.35 [1/4] 15.88[5/81 N/A 8/1.00 15/0.99 19/0.98 1310.98 7/0.97 2/0.97 NR NR " ',NR' NR ' •' 5.3 kW 7.94[5/16] 15.88[5/81 N/A 8/1.00 15/0.99 23/0.98 30/0.98 28/0.97 27/0.97 ;26/0.96 24/,0;96; 22/0.95- 21./ M [1.5 Ton] 9.53 [3/81 15.88[5/8] 54 8/1.00 15/0.99 23/0.98 30/0.98 30/0.97 30/0.97 30/,0 96. 30/0:96 30/0:95 30./0 94 **SEE 6.35 [1/4] 19.05[3/4]-' N/A. 8/1.00 15/1.00 19/0.99 13/0.99 7/0.99 2/0.99 ,.:NR NR.,: ', NR° ''NR NOTE 3 7.94 15/16] 19.05[3/4]** N/A= 8/1.00 15/1.00 23/0.99 30/0.99 28/0.99 27/0.99 25/0.99 24/0.98 22/0.98 21/0.98 9.53 13/8] 19.05[3/4]** "54- 8/1.00 15/1.00 23/0.99 30/0.99 3010.99 30/0.99 30/0.99 30/0.98 30/0.98 30/0.98 6.35 [1/4] 15.88[5/8] N/A 8/0.99 15/0.98 6/0.97 A' NR.• . '.�NR ' '� �NR.` . • . ; ,NH : ; NR m'. NR ' `,NR •.; 7.94[5/16] 15.88[5/8] 65 8/0.99 15/0.98 23/0.97 27/0.96, 23,/--0.95" 21:/;0.94- - 1.9/0.93 =16/0:92: 14/0.91 '11 L 0:90 7.0 kW 9.53 [3/8] 15.88[5/8] 43 - 8/0.99 15/0.98 23/0.97 30./0.9.6. 30/0.95 -3010:94 30/: '.93 29'/'0 92 28%.6.91, 27/0.90' [2 Ton] 6.35 [1/4] 19.05[3/4] N/A 8/1.00 _ 15/1.00 6/0.99 NR. -NR A MR' e , �NR NR :NR 7.94[5/16] 19.05[3/4] 65, ' 8/1.00 15/1.00 23/0.99 27/0.99 23/0.98 21/0.98 19/0.98 16/0.97 14/0.97 11/0.96 , 9.53 [3/81 19.0513/4] 43-- 8/1.00 15/1.00 23/0.99 30/0.99 307 0.98 30/0.98 30/0.98 29/0.97 28/0.97 27/0.96- 7.94[5/16] 15.88[5/8] N/A 8/0.99 15/0.98 23/.0.96 21/0.94 18/0.93, 15:/0:91" 11/0.90 NR :NR ;NR GZ 8.8 kW 9.53 13/8] 15.88[5/8] 43'- 8/0.99 15/0.98 23/0.96 301.0.94 301 0.93•` 29 X'0:91. . 27/0.90 :NW NR;' 'NR. 12.5 Ton] 7.94[5/16] 19.05[3/4] 65 8/1.00 15/0.99 23/0.99 21/0.98 18/0.98 15/0.97 11,/0.96 8/0.96 - .4/0.95 NR 9.53 [3/8] 19.05[3/4] 43 8/1.00 15/0.99 23/0.99 30/0.98 30/0.98 29/0.97 27/0.96 26/.0;W 2510.95 24%0.95' 7.94[5/16] 15.88[5/8] -N/A 8/0.99 15/0.97 =20/A.94 15/0192' 16/0 90-„ : " AIR' "NR NR NR;'•' NR 9.53 [3/8] 15.88[5/8] 33 8/0.99 15/0.97 23/0.94 29'/0.92 27/0.90 NR NR; NR " ?NR: • NR 7.94[5/16] 19.05[3/4] N/A 8/1.00 15/0.99 20/0.98 15/0.98 10/0.97 .5'/0`96 NR•, NR ,NW' NH 10.6 kW 9.53 [3/8] 19.05 13/4] 33 8/1.00 15/0.99 23/0.98 29/0.98 27/0.97 ;26/0.96- - 24/0.95 ,22/0 94 20/0.93 19/0.93. [3 Ton] 12.7 11/2] 19.0513/4] 17'' 8/1.00 15/0.99 23/0.98 30/0.98 30/0.97 30/.0:96 3010.95 30/0.94,, 30%0.93' 3010.93 7.9415/16] 22.23[7/8] N/A'. 8/1.00 15/1.00 20/1.00 15/0.99 10/0.99 5/0.99 ;:NR NR MR T MR'. 9.53 [3/8] 22.23[7/81 33' 8/1.00 15/1.00 23/1.00 29/0.99 27/0.99 26/0.99 24/0.98 22/0.98 20/0.98 19/0.97 1/2 [12.7] 22.23[7/8] 17_ 8/1.00 15/1.00 23/1.00 30/0.99 30/0.99 30/0.99 30/0.98 30/0.98 30/0.98 30/0.97 9.53 [3/8] 19.05[3/4] 46 8/0.99 15/0.98 23/0.97 27/0.9fi 24/6.95;. '2210.94 20/0.92 17/0.91 15/0.90 ::•NR" JL6 12.3 kW 12.7 [1/2] 19.05[3/4] 23 _ 8/0.99 15/0.98 23/0.97 30/0.96 .3010.95 '30/0.94 30/,0:92 ' 30/0.91- ' 30•10.90 `'.•NR D [3.5 Ton] 9.53 [3/8] 22.23 17/8] 46-. 8/1.00 15/1.00 23/0.99 27/0.99 24/0.99 22/0.98 20/0.97 17/0.97 15/0.96 13/0.96 12.7 11/2] 22.23[7/81 23 8/1.00 15/1.00 23/0.99 30/0.99 30/0.99 30/0:98 30/0.97 30/0.97 '30-/0.96 307 0.96 m NOTES: w 1)Do not exceed 61 meters linear line length. m (D 2)*Do not exceed 30 meters vertical separation if outdoor unit is above indoor unit. m '� 3)*19.05 mm[3/4 in.]vapor line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor unit to assure proper oil return. w 4)Always use the smallest liquid line allowable to minimize refrigerant charge. m 5)Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended,but are allowed. m 6)Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop. 0 3 OR 0 Refrigerant Line Size Information (con't.) JL6 13-16 SEER Single-Stage Air-Conditioners D Apply Long Line Equivalent Length(Meters) Allowable Allowable Guidelines if Linear Line �o Liquid Line Suction Line Length Exceeds Those Unit Size Size Size Shown Below (Meters) 8 8 15 16 23 24 30 31 38 39 46 47-53 54 61 62-69 70-76 y C mm[in.] mm[in.] �. Maximum Vertical Rise(Outdoor Unit Below Indoor Unit)*/Capacity Multiplier y r r 9.53[3/8] 19.05[3/4] 45 8/0.99 15/0.98 23/0.96. 24/,005 20/0,93, 1T%`0:92 14 14.1 kW 12.7[1/2] 19.05[3/4] 23: 8/0.99 15/0.98 29/0.06 3010:95 ', $0/0.93' 30 l0:92 30/0 91 � ;:`NR � _ �a� a �aNR NR m 14 Ton] 9.53[3/81 22.23[7/8] 45 8/1.00 15/0.99 23/0.99 24/0.98 20/0.97 17/0.97 14/;0 96;' 11/.0:96 8,/0.95 5/0 95 12.7[1/21 22.23[7/8] 23" 8/1.00 15/0.99 23/0.99 30/0.98 30/0.97 30/0.97 301,0:96 30•/0.96 "80/0 95 :, 30/0:95 9.53 3/8 24 8/0.99 15/0.97 23'/0:94 _, 19 C092 ; ` 14/0 90 'NA";w NR r Nfi[ ] 19.05[3/4] 12.7[1/2] 19.05[3/4] 12 8/0.99 15/0.97 2V ON 30/ .'927 4010 90 NR 17.6 kW 9.53[3/8] 22.23[7/8] 24 8/1.00 15/0.99 23/0.98 19/0.97 14/'0.96 , '10/0 05, .5 T0:94 NRF.W Qa,NR F ;NR [5 Ton] 12.7[1/2] 22.23[7/8] 17 8/1.00 15/0.99 23/0.98 30/0.97 3040:96• 30/.0 95 30 Y:0:94, 29/0 94 28•/0 93 27/,0.92 9.53[3/8] 28.58[1-1/8] 24_', 8/1.01 15/1.01 23/1.00 19/1.00 14/0.99 10/0.99 5/0.99 :"NR 12.7[1/2] 28.58[1-1/8] 1Z 8/1.01 15/1.01 23/1.00 L30/1.00 30/0.99 30/0.99 30/0.99 29/0.99 28/0.99 27/0.98 NOTES: 1)Do not exceed 61 meters linear line length. 2)*Do not exceed 30 meters vertical separation if outdoor unit is above Indoor unit. 3)*19.05 mm[3/4 in.]vapor line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor unit to assure proper oil return. 4)Always use the smallest liquid line allowable to minimize refrigerant charge. 5)Applications shaded in light gray indicate capacity multipliers between 0:90 and 0.96 which are not-recommended,but are allowed. 6)Applications shaded in dark gray are-not recommended due to excessive liquid or suction pressure drop. Air Performance Data �i I RA13 Series Performance Data @ AHRI Standard Conditions-Cooling Designated Tested Combination(DTC) Outdoor Total Capacity Net Sensible Net Latent Indoor CFM Unit Indoor Coil BTU/H[kW] BTU/H[kW] BTU/H[kW] SEER EER [L/s] RA1318 RCF2417STA 17600 [5.2] 12600, [3.7] 5000[1.5] 13.00 11.00 600[283.2] RA1324 RCF2417STA 23400 [6.9] 17500 [5.1] 7000[2.1] 13.00 11.00 800[377.6] RA1330 RCF3617STA 28400 [8.3] 21000 [6.2] 7400[2.2] 13.00 .11.00 1000[471.9] RA1336 RCF3617STA 34600 110.1] 23400 [6.9] 11200[3.3] 13.00 11.00 1025[483.7] RA1342 RGF4821STA 40500[11.9] 28700 [8.4] 11800[3.5] 13.00 11.00 1400[660.7] RA1348 RCF4821STA 47500[13.9] 34000[10.01 13500[4.0] 13.00 11.00 1500[707.9] RA1360 RCF6024STA 56000[16.4] 39600[11.6] 16400[4.8] 13.00 11.00 1600[755.1] Note:Additional ratings and system match ups can be accessed on MyRheem.com at httpsJ/my.rheem.com/static/private/andresidenbal.htmi Additional ratings and system match ups and downloadable ratings certificates can be accessed from the AHRI website:www.anddirectory.org [ ]Designates Metric Conversions INTEGRATED • COMFORT 17 -on Air Guide Specifications 0 I RA13 Series GUIDE SPECIFICATIONS General AIR-COOLED,SPLIT-SYSTEM AIR CONDITIONER System Description RA13 Outdoor-mounted, air-cooled, split-system air conditioner comm 1-1/2 TO 5 NOMINAL TONS posite base pan unit suitable for ground or rooftop installation. Fans Unit consists of a hermetic compressor, an air-cooled coil, pro- — Condenser fan will be direct-drive propeller type, discharging peller-type condenser fan, suction and legend line service'valve, air upward. and a control box.Unit will discharge supply air upward as shown — Condenser fan motors will be totally enclosed, 1-phase type on contract drawings.Unit will be used in a refrigeration circuit to with class B insulation and permanently lubricated bearings. match up to a coil unit. Shafts will be corrosion resistant. Quality Assurance — Fan blades will'be statically and dynamically balanced. — Unit will be rated in accordance with the latest edition of AHRI _ Condenser fan openings will be equipped with coated steel Standard 210. wire safety guards. — Unit will be certified for capacity and efficiency, and listed in Compressor the latest AHRI directory. — Compressor will be hermetically sealed. — Unit construction will comply with latest edition of ANSI/ — Compressor will be mounted on rubber vibration isolators. ASHRAE and with NEC. — Unit will be constructed in accordance with UL standards and Condenser Coil will carry the UL label of approval. Unit will have c-UL-us — Condenser coil will be air cooled. approval. — Coil will be constructed of aluminum fins mechanically bonded — Unit cabinet will be capable of withstanding ASTM 131171000- to copper tubes. hr salt spray test. Refrigeration Components —Air-cooled condenser coils will be leak tested at 150 psig and — Refrigeration circuit components will include liquid-line shutoff pressure tested at 550 psig. valve with sweat connections, vapor-line shutoff valve with — Unit constructed in IS09001 approved facility. sweat connections, system charge of R-410A refrigerant, and Delivery,Storage,and Handling compressor oil. — Unit will be shipped as single package only and is stored and — Unit will be equipped with filter drier for R-410A refrigerant for handled per unit manufacturer's recommendations. field installation. Warranty(for inclusion by specifying.engineer) — U.S.and Operating Characteristics Canada only. —The capacity of the unit will meet or exceed Btuh at a suction temperature of °F/°C. The power consumption Products at full load will not exceed kW. Equipment — Combination of the unit and the evaporator or fan coil unit will have a total net cooling capacity of Btuh or greater at Factory assembled, single piece, air-cooled air conditioner unit. conditions of CFM entering air temperature at the evap- Contained within the unit enclosure is all factory wiring, piping, orator at °F/°C wet bulb and °F/°C dry bulb, and controls,compressor,refrigerant charge R-410A,and special fea- air entering the unit at , °F/°C. tures required prior to field start-up. —The system will have a SEER of Btuh/watt or greater at Unit Cabinet DOE conditions. — Unit cabinet will be constructed of galvanized steel, bonder- Electrical Requirements ized,and coated with a powder coat paint. — Nominal unit electrical characteristics will be v, single —All units constructed with louver coil protection and corner post. phase,60 hz.The unit will be capable of satisfactory operation Louver can be removed by removing one fastener per louver within voltage limits of v to V. panel. — Nominal unit electrical characteristics will be v, three phase,60 hz.The unit will be capable of satisfactory operation within voltage limits of v to v. — Unit electrical power will be single point connection. — Control circuit will be 24v. Special Features — Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements. COMFORTINTEGRATED HOME Air Limited Warranty RAf3 Series GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product Conditional Parts which fails in normal use and service within the applicable (Registration Required)...............................Ten(10)Years period stated,in accordance with the terms of the limited warranty. 'For complete details of the Limited and Conditional Warranties,including applicable terns and conditions,contact your local contractor or the Manufacturer for a copy of the product warranty certificate. INTEGRATED19 • • •- 1 „ The new degree of comfort? In keeping with its policy of continuous progress and product improvement Rheem reserves the right to make changes without notice. Rheem Heating,Cooling&Water Heating • 5600 Old Greenwood Road Rheem Canada Ltd./Ltge • 125 Edgeware Road,Unit 1 Fort Smith,Arkansas 72908 • www.rheem.com Brampton,Ontario • L6Y 0135 INTEGRATED HOME COMFORT PRINTED IN U.S.A.6/1 B QG FORM NO.A11-221 REV.8