Loading...
HomeMy WebLinkAbout1000-123.-5-31 OFFICE LOCATION: (O MAILING ADDRESS: Town Hall Annex P.O. Box 1179 54375 State Route 25 Southold, NY 11971 (cor. Main Rd. &Youngs Ave.) Southold, NY 11971 Telephone: 631 765-1938 1 LOCAL WATERFRONT REVITALIZATION PROGRAM TOWN OF SOUTHOLD To: Glenn Goldsmith, President Town of Southold Board of Trustees Cc: Honorable Lori Hulse, Attorney From: Heather Lanza, AICP, Planning Director LWRP Coordinator Date: September 11, 2026 Re: LWRP Coastal Consistency Review ROBERT R AUTERI LIVING TRUST & NANNETTE M. AUTERI LIVING TRUST, SCTM #1000-123.-5-31 This application is to remove the existing sanitary system and replace it with a new I/A sanitary system consisting of a Fuji Clean Cen 5 treatment tank, an inlet adapter 90, an Orenco pump and 52' of Quick 4 plus standard infiltrators designed as a combined system serving both the main house and the cottage; and to install and maintain silt fencing around the work area until the site is fully stabilized. The proposed action has been reviewed under Chapter §268, Waterfront Consistency Review of the Town of Southold Town Code and the Local Waterfront Revitalization Program (LWRP) Policy Standards. Based upon the information provided on the LWRP Consistency Assessment Form submitted to this department, as well as the records available to me, it is my recommendation that the proposed action is CONSISTENT with the policies of the LWRP as follows: Policy 5. Protect and improve water quality and supply in the Town of Southold. 5.1 Prohibit direct or indirect discharges that would cause or contribute to contravention of water quality standards. C. Ensure effective treatment of sanitary sewage and industrial discharges by: 3. modifying existing sewage treatment facilities to provide improved nitrogen removal capacity. Policy 6. Protect and restore the quality and function of the Town of Southold ecosystem. 6.3 Protect and restore tidal and freshwater wetlands. A. Comply with statutory and regulatory requirements of the Southold Town Board of Trustees laws and regulations for all Andros Patent and other lands under their jurisdiction The proposed installation of an Innovative/Alternative Onsite Wastewater Treatment System (I/A OWTS) is consistent with Policy 5.1.C.3, which calls for the replacement of existing sewage treatment facilities with ones that have improved nitrogen removal capacity. The proposed I/A OWTS will reduce nitrogen inputs into adjacent waters. The proposed I/A OWTS is consistent with Policy 6.3.A, which states that actions must comply with the Southold Town Board of Trustees' laws and regulations. The proposed location meets the wetland setbacks stated in Town Code Chapter §275-5D(a)[4] Septic tank. 75 feet. The proposed action has been reviewed under Chapter §268, Waterfront Consistency Review of the Town of Southold Town Code and the Local Waterfront Revitalization Program (LWRP) Policy Standards. 2 Town of Southold Q C� 7 LWRP CONSISTENCY ASSESSMENT FORM AUG 2 S 2026 SOUTHOLD TOWN A. INSTRUCTIONS P�.N�a�Nc BOARD 1. All applicants for permits* including Town of Southold agencies, shall complete this CCAF for proposed actions that are subject to the Town of Southold Waterfront Consistency Review Law. This assessment is intended to supplement other information used by a Town of Southold agency in making a determination of consistency. *Except minor exempt actions including Building Permits and other ministerial permits not located within the Coastal Erosion Hazard Area. 2. Before answering the questions in Section.C, the preparer of this form should review the exempt minor action list, policies and explanations of each policy contained in the Town of Southold Local Waterfront Revitalization Program. A . ro osed action will be evaluated as to its sienificant beneficial and adverse effects upon the coastal area(which includes all of Southold Town). 3. If any question in Section C on this form is answered "yes" or "no", then the proposed action will affect the achievement of the LWRP policy standards and conditions contained in the consistency review law. Thus, each answer must be explained in detail, listing both supporting and non- Enporting facts. If an action cannot be certified as consistent with the LWRP policy standards and conditions,it shall.not be undertaken. A copy of the LWRP is available in the following places: online at the Town of Southold's website (southoldtown.northfork.net), the Board of Trustees Office, the Planning Department, all local libraries and the Town Clerk's office. B. DESCRIPTION OF SITE AND PROPOSED ACTION scTM# 123 _05 _ 31 AW e , PROJE CT 3885 Camp Mineola Road- Town of Southold The Application has been submitted to(check appropriate response): Town Board ❑ Planning Board❑ Building Dept. ❑ Board of Trustees ❑✓ 1. Category of Town of Southold agency action(check appropriate response): (a) Action undertaken directly by Town agency(e.g. capital ❑ construction,planning activity, agency regulation,land transaction) ❑ (b) Financial assistance(e.g. grant,loan,subsidy) (c) Permit, approval;license,certification: ❑✓ Nature and extent of action: See attached P Location of action:3885 Camp Mineola Road,Mattituck,NY 11952 Site acreage:0.252 Present land use:Res. Present zoning classification:Res. 2. If an application for the proposed action has been filed with the Town of Southold agency, the following information shall be provided: (a) Name of applicant:Auteri RP Living Trust and Auteri NM Living Trust (b) Mailing address:4 Pidgeon Ct,Manorville,NY 11949 (c) Telephone number: Area Code 516-768-7990 (d) Application number,if any: Will the action be directly undertaken,require funding,or approval by a state or federal agency? Yes 0 No❑ If yes, which state or federal agency?NYSDEC,SCDHS _ C. Evaluate the project to the following policies by analyzing how the project will further support or not support the policies. Provide all proposed Best Management Practices that will further each policy. Incomplete answers will require that the form be returned for completion. DEVELOPED COAST POLICY. Policy 1. Foster a pattern of development in the Town of Southold that enhances community character, preserves open space, makes efficient use of infrastructure, makes beneficial use of a coastal location, and minimizes adverse effects of development. See LWRP Section III—Policies; Page 2 for evaluation criteria. FV]Yes ❑ No ❑ Not Applicable Project is consistent with neighboring area and makes beneficial use of property.Proposed new construction with I/A style sanitary system. Attach additional sheets if necessary Policy 2. Protect and preserve historic and archaeological resources of the Town of Southold. See LWRP Section III—Policies Pages 3 through 6 for evaluation criteria ❑ Yes ❑ No 0 Not Applicable No Effect. Attach additional sheets if necessary Policy 3. Enhance visual quality and protect scenic resources throughout the Town of Southold. See LWRP Section III—Policies Pages 6 through 7 for evaluation criteria ❑ Yes ❑ No❑✓ Not Applicable No Effect Attach additional sheets if necessary NATURAL COAST POLICIES Policy 4. Minimize loss of life, structures, and natural resources from flooding and erosion. See LWRP Section III—Policies Pages S through 16 for evaluation criteria ❑ Yes ❑ No Z Not Applicable No effect Attach additional sheets if necessary Policy 5. Protect and improve water quality and supply in the Town of.Southold. See LWRP Section III —Policies Pages 16 through 21 for evaluation criteria 0 Yes ❑ No ❑Not Applicable Project provides new sanitary system that has a positive effect on wetlands due to I/A style sanitary system with reduced nitrogen outflow. Attach additional sheets if necessary Policy 6. Protect and restore the quality and function of the Town of Southold ecosystems including Significant Coastal Fish and Wildlife Habitats and wetlands. See LWRP Section III— Policies; Pages 22 through 32 for evaluation criteria. ❑Yes Do ❑✓ Not Applicable No Effect. Attach additional sheets if necessary Policy 7. Protect and improve air quality in the Town of Southold. See LWRP Section III — Policies Pages 32 through 34 for evaluation criteria. ❑ Yes ❑No❑✓ Not Applicable No Effect. Attach additional sheets if necessary Policy 8. Minimize environmental degradation in Town of Southold from solid waste and hazardous substances and wastes. See LWRP Section III—Policies; Pages 34 through 38 for evaluation criteria. ❑Yes ❑ No ✓❑ Not Applicable No Effect. PUBLIC COAST POLICIES Policy 9. Provide for public access to, and recreational use of, coastal waters, public lands, and public resources of the Town of Southold. See LWRP Section III—Policies; Pages 38 through 46 for evaluation criteria. ❑ Ye❑ No R1 Not Applicable No effect Attach additional sheets if necessary WORKING COAST POLICIES Policy 10. Protect Southold's water-dependent uses and promote siting of new water-dependent uses in suitable locations. See LWRP Section III•—Policies; Pages 47 through 56 for evaluation criteria. ❑Yes ❑ No❑✓ Not Applicable No Effect. Attach additional sheets if necessary Policy 11. Promote sustainable use of living marine resources in L 62 for evaluation c Island Sound, the rter aic Estuary and Town waters. See LWRP Section III—Policies; Pages 57 through ❑Yes ❑ No 0 Not Applicable No effect. Attach additional sheets if necessary Policy 12. Protect agricultural lands in the Town of Southold. See LWRP Section III—Policies; Pages 62 through 65 for evaluation criteria. ❑Yes ❑ No 0 Not Applicable No Effect. Attach additional sheets if necessary PY olic 13. Promote appropriate use and development of energy and mineral resources. See LWRP Section III—Policies; Pages 65 through 68 for evaluation criteria. ❑Yes ❑ No❑✓ Not Applicable No Effect. Agent DATE-- PREPARED B Y Karol Carvajal TITLE g_ — TCe'JN OF SOUTHOLD SUFFOLK COUNTY, NY 11971 3885 Camp Mineola Rd SCTM No. 1000-123-5-31 0410912026 Photo 3- 33885 Camp Mineola Rd ............................ .�- .. ...... :.e.-r `. _ 6 0410912026 Photo 4- 3885 Camp Mineola Rd TCZVN OF IOUTHOLD SUFFOLK COUNTY,NY 11971 3885 Camp Mineola Rd SCTM No. 1000-123-5-31 f I - t n a 04/09/2026 Photo 1- 3885 Camp Mineola Rd "rf 0410912026 Photo 2- 3885 Camp Mineola Rd 3/27126.2:57 PM 3885_CampMineoland_FLOOR_PLAN.jpg PORCH is 27' 162" L t F7DINING LMNG ROOM 13=3314' TT-T7 E A0 COND � N CD �'''� IuIURPHY BED HT RL f� ��JJ < t✓ m GUEST r g m BEDROOINSTUDY m to h <1 CA oS { E s aL � m El 25' DESK L 34" I r rR TOLEr 30"—{ At fiL I a Pa,,DAlMuQ RL FOYER 0 60" ` L T 3. 4219 - _ 68' 41'- COAT DnaC.� k BENCH n wA�rU� L ffar a CLOSCT CLt" 100"� Ri'z m tit z 16 2' W MASTER BEDROOM co m BOB&NANNETTE AUTERI O0 3885 CAMP MINEOLA ROAD,MATTITUCK U RENOVATION FLOOR PLAN WIP 3 0 - - - euaEAu SCALE:1/4"=1 FOOT TYPICAL CEIUNG HEIGHT=88" 24 roavta LOW SECTION CEILING HEIGHT-70" a uv Op „0' 15 WINDOWS(21N ATTIC) L 2 ENTRANCE DOORS,1 GIASTER BATH aIL 48 cEts SERVICE DOOR 2 BEDROOMS 30 1&112 BATHROOMS WA rER 0 N " 5YS1 L 7 I r7 13'-8 313" https://mail.google.com/mail/u/O/#searchlrpafiberman°/a40aol.com/KtbxLwgsxgDNTWX(JksMWSSXjcnWvdjNJq?projector=l&messagePartld=0.1 1/1 L TOILET VANITY 9f 4FAN $' B@@ WH BATHROOM 9' �p CF D WH NDERCA SINK REFRIG CL BEDROOM Mir 68"� O KITC o Tit— BUREAU N CL TABLE �L CL SET co 19 B 0 B&NANNETTE AUTERI 8' 3885 CAMP MINEOLA ROAD, MATTITUCK COTTA E_RENOVATION_FLOOR_PLAN LIVING AREA CF N SCALE: 1/4"= 1 FOOT CL °O REVISION—B DH WH 1/10/2016 mN LEE 6FL.E911L `• •. '.\. \ ___ � I .. i+�,- E , • f L[E 6CC I10 IIL- ^$- FEE SECF a ` `• , Y . '. caa PG.Fo � n � y;�� •' Qc � ,�Off;� ... a E r� -; � � 1 °�ES�� I R �51. \ t Lx� C 5/tr��'F y lye to ..1. 1�!°'D. •.` _ /_ t .�•� `� ? aOIF waa \ '.y \'•- a"-i::•.....r- °,, o s, `� +e.l r t � ,z�, �' I �y l 1 S• 4 �pq ,�,1 '.,Ed1iKl.FO�. \ ''•,R I 1 .- 1}, 4_♦l x: ,° ±'.' °u l aLLt<I LR l to', .I sµ<I.s.. '� (19 LEESMW. i •1£.`r :R ..k.:�_'^1::•.„n ri.. :`l 41w.l slwL1.,.1a1•;' R el. , \. 131OSG01 .�f C ..S R � l ,E,5 [�: t ��1 1, .G ``• R:-".''`. - - I ' l�,L �G.'-� ti' ,Y, ` C ra�sl'ri Ln -, v ..__• ' _ � _ , low "1 yla R �..YSZ- ,At.;,t, =Oq NefL 0 P is ._ _.- /..•; - I �� 'l,a1.,.-'n l i 21, - n 1` „_ .-y-•-•;":•. XI ~ r.IF a. Q� _ �'I••y I -� a 'i. � I `.'+?.'- ',t .Z�••.lL•! -.n..+` �l •- j•�`!FI'�� �'���.°.,� �pS, - 7 '• - f •.1'R p' `1 l]F ?Oµ1�}t fT3f�n`•�\M1�'•911.1„ `4�.0`' r .) u t l,fl•,p' l•:.. , , V'• N ♦ ya P,11°♦R� Cj'..e;�. Lr E a 1' `J^i! t' 1° n.... P:. ++^ ..10 4 4•A, e11. \ j.P fife- Ll .. '. I Y - l !.piu'_.•'u' l° ?t.. y ^ _ ..• 1 - - ,� .. 1 ;µcl•.tail.�\, 1�: y,le .y,,.• _ �`�. -'e.l_ ' - - �t' I J't` +Qµai\�°ri,1. _ •�1 tt .!`\ • .L"L � „t 4- -11TM+w ` 1p1„l • n •_�Y-n'Y'..t .. .--_.. �, , •.''` 19eF11 `J;• lt' j5,�a� ,1 1 _ t„f �. \ ♦ ♦ 1 on t =�'»'��^•••�`^�,• "°w""p — t tl COUNTY OFSUFFOLK C rmTCE _ �.Kt�, loon secralw �... .,......n. Seniee Agency u,lauxcE.nrllwv.euEw na r W 61fHU1COJT'>��6WWIiE° A `Oj N 90U1NOl➢ 123 z SANITARY CALCULATIONS TANK CALCULATIONS: FLOW=4 BEDS(110 GAUDAY)=440 GAUDAY SITUATE AT MATTITUCK CAPACITY FOR FUJI CEN5=749 GAL TOWN OF SOUTHOLD INFILTRATOR CALCULATIONS: SUFFOLK COUNTY, NEW YORK 0) 2 x O1 l�►1��®�� r FLOW=4 BEDS(110 GAUDAY)=440 GAUDAY SCTM° 1000-123-05-31 L'I _ `00 � $� W (440 GALIDAY)/(2.83 LF)1(3.0 GAUDAYISF)=51.83 LF LYi 51.83 LF REQUIRED z �J O 52 LF PROVIDED W U 0*\ 2 ROWS OF 26 LF 12°STANDARD INFILTRATORS (OFAq FC O Jed' H F. h w T ul CIO O°Zo Or 5O EXISTING OVERHEAD �F 40 �� * `\CC w\S` Z w ELECTRIC WIRES TO W W o REMAIN N c2 > QO O Ld z �FF�q act o SITE PLAN Gc 0DaL I G E� <O°O o SCALE:1"=20' r Z w� PUBLIC WATER 20 w $:x w 3 y- o � DIST 1000-SEC 123-BLK 5-LOT 32.0 '�F Q 1 O 20 V 1 15 w y Q PROPOSED FUTURE q� C O �c37�0 � EXPANSION EXISTING UNDERGROUND m ELECTRIC SERVICE TO REMAIN Q w o 0 PROPOSED 26'QUICK 4 z r PLUS STANDARD PROPOSED rr I m °zz y INFILTRATORS(TYP-2). ORENCO PUMP S 04°01 20 E — — — WC D RET WALL W WALL 201 77' �' -.6 2H o M ON R WALL �X X p ° 3 3— 3— 3— _ 3 3— 3— ° WOOD GROIN o .t: TEST PROPOSED m - 1______ __ SEPTIC h TOTAL AREA=0.252 ACRES _ �„ 1-6 BORING CONTOUR L____EXPANSION_ _ J w COVEFj_x R 10,970 SF o HOLE r m Z U SILTPOSED FENCE ABANDON EXISTING (� Q \ Y S ONE WALK '., 26'INFILTRATOR a p Q '-' SANITARY SYSTEM 9 Z Lj- aoaa OD o°OaBooDOD�a g�MIN N IL d ` ` svW �Q a 4L T. 00 _ ILL!o X o PROPOSEDI/A DO Go � s m D - ELECTRIC LINE^ w 26.2 10:2' e. > (� Z U Q; VEREO m PROPOSED I/A� CH o' CONTROLPANEL X = c O o r w v POR PAVER 743 co m N Y � M CONCRETE 7' z PROPOSED I/A PA 710 w tO\EXISTING ONE STORY SIN X w 0 �..iYDAPRON 281' 6 -,, AIRLINE uj FAMILY EMAIN - COVERED N '" a O � 0 J (� ,\ 1 rn o x TING 2BEDS) PORCH 16 d O O (ter EXISTING ONE STORY - xn COV R Q -- ----y' 'n CRAWL SPACE=915SF �`+ N r (( �� /^� U COTTAGE TO REMAIN �o� v' O 14.o' 1ST FL=900 SF IN�M - LLJ LJ. °az rq \ c (EXISTING 1 BED) C.O FF EL 7.3 ALUM O F-- 0 y w3 CRAWL SPACE=574SF 1 ®' °� STONES\ STAIRS z j 1ST FL=567SF 5M a� \ \ O O� cx w: GRASS 0 r�0a O� F.FEL.6.70 I z r 4V\o' N G.FE\4.7 NCO_-,R n� � \\ \� 17.7' 10.2' O� N� 'II VOz of wM Zg.2 J a sus 22.5' �] vc 1 m _.CO CO W w g z s 3 v" \ STONES v vi A 00 N z W WM-WM M - W .- YM W X U' W WY 2 v v CH LI K FENCE . IE BORDER % CONCRETE WALL 0 (n W z � rya m PROPA ? X — 5 y'z e z 1-.10, � N 03`40' 0" W 00 TANKS X Q a �w m PROPANE pg� FENCE 178.25 - E--I Zo „a NOTES: U d TANKS EXIT TINGABOVEGROUND N n 7 PROPOSED FUJI m U O PROPANE TANKS AND GAS o ' g 1. ALL PROPOSED SANITARY LINES TO BE 4'0 SDR35 PVC PIPE UNLESS SPECIFIED Lt1 ABANDON EXISTING CLEAN CEN-5- r SERVICE TO REMAIN OTHERWISE. 1 O (O SANITARY SYSTEM TREATMENT TANK n w a 2. NO NEIGHBORING WELLS WITHIN 150 FT OF THE PROPOSED SANITARY SYSTEM. p ` O O PROPOSED VENT 2'MIN,W/ PROPOSED FUJI CLEAN �1 3. ALL UNDERGROUND STRUCTURE LOCATIONS ARE APPROXIMATE AND SHOULDQ, m EXISTING WATER CHARCOAL FILTER MIN.3' INLET ADAPTER 90. z BE VERIFIED IN THE FIELD BY THE CONTRACTOR BEFORE CONSTRUCTION y , SERVICE TO REMAIN FROM DOORSI WINDOWSD LLIN BEGINS. N �- >' w 4. REFER TO ARCHITECTURAL DRAWINGS FOR ALL INTERIOR HOUSE DIMENSIONS. 2` PUBLIC WATER \ - PROJECT 5. DWELLINGS HAVE A TOTAL OF 3 BEDS,HOWEVER THE SANITARY SYSTEM IS 7' m DIST 1000-SEC 123-BLK 5-LOT 30 DESIGNED PER THE CAPACITY REQUIREMENTS FOR 4 BEDROOMS DWELLING. Q` V LOCATION of� I 1--1 EXIST.GRD=4.8(PECONIC SURVEYORS,P.C.) HIGHEST EXPECTED GROUNDWATER INFORMATION LOCATION MAP THE AREA IS SUBJECT TO TIDAL ACTION SO HIGHEST EXPECTED Q m 0,0'-2.6 MIXED SAND OL GROUNDWATER IS MEAN HIGH WATER(MHW). �� t 6,� y 0 0 H AND LOAM BENCHMARK 8512735 Eo BENCHMARK STAMPING:NO 1 1917 �\ , ` F Z 0 2.6-3.8' BROWNSILTYSAND SM MLLW=1.848 METERS=6.063 FT 7f �. i-. GROUNDWATER EL 1.0 ORTHO HT=1.211 METERS=3.97 FT ! h O O `L (HIGHEST EXPECTED) DIFFERENCE=2.093 FT �`� 'l W p j m WATER IN MHW=0,917 METERS=3.008 FT(MLLW DATUM) f / t Z z 0 tO 3.8'-4.0' BROWN SILTY SM MHW OR HIGHEST EXPECTED GROUNDWATER=0.915 FT(NAVD88) �' 100 U c m SAND CALCULATED MHW ELEVATION IS LESS THAN GOUNDWATER J i a Y O y o ENCOUNTERED IN SOIL BORING THEREFORE THE .,. ., ./ /, n( LL ' GROUNDWATER TAKEN IS THE HIGHEST EXPECTED sno.g:hwm�. i Q r 0 0 GROUNDWATER 4.0'-13.0' WATER IN PALE SP g , 1� 1 Lo BROWN FINE /r i I ; i00 SAND �� J 4 M O BORING BY:MCDONALD GEOSCIENCE ` a• I ,� ( I TAKEN ON:MARCH 18,2014 t !! ('q NOTE:WATER ENCOUNTERED AT 3.8' ('ab'! BELOW GRADE. mt"°°° `�'`O� .� L.L i/ r� O TEST BORING HOLE ^ —� � , W N.T.S. a/� _ U) z w HDUBE BUOYANCY CALCULATIONS z FUJI CLEAN INLET �/ z M COTTAGE ADAPTER 90 C/O TO WEIGHT OF FUJI CEN5=463 LBS EACH O GRADE EL.5.2 WEIGHT OF BUOYANCY KIT=2,412 LBS ' ooa (2 X 8'X 1.5'X 0.6T X 150) I no C.O.TO GRADE. COVERS TO COVER TO GRADE ROUND ELEVATION 5.0 WEIGHT OF SATURATED SOIL ABOVE BUOYANCY KIT=5,359 LBS LJ j Z C00 .O.TO GRADE. EL.4.8 GRADE EL.5.2 EL 5.0 (2 X 8'X 1.6 X 2.03'X 110) Ljl WEIGHT OF SOIL ABOVE BUOYANCY KIT ABOVE HIGHEST EXP.=9,072 LBS Z O [Ia U DISTAL HEAD HEIGHT 24' (2 X 8'X 1.6 X 4.2'X 90) LI- n-•i TOTAL=17,308 LBS �O -- 12'MIN.COVER TOP L.4.00 v/ 13.30'PRESSURIZED PIPE BUOYANCY FORCE ON SEPTIC&TREATMENT TANK ASSUMING TANK IS EMPTY TOP EL.3.7 12-LP INFILTRATOR AND GROUND WATER IS UP TO HIGHEST EXPECTED GROUNDWATER C [� �`Z,_155.85' _ 2 ROWS-26'LONG BOTEL.3.00 7.9'X 4.0'X 2.70'X 62.4=5.324 LES __ 5.00, ORENCO INV.EL. INV.EL.3.67 CC 21.75' PUMP 3.33 17,306 LBS SEPTIC TANK>5,324 LBS(3.25 FACTOR) PROPOSED INV.EL. z FUJI CLEAN CENS TANK 2.53 INVZ 47 N WEIGHT OF ORENCO DISCHARGE ASSEMBLY=26 LBS EACHcn INV.EL,2.7 (NEEDS BUOYANCY KIT) WEIGHT OF CONCRETE DEADMAN=530 LBS (PI(1.5')^2)X 0.50'X 150) i r TOTAL=556 LBS sa HIGHEST EXPECTED BUOYANCY FORCE ON PUMP BASIN ASSUMING IT IS EMPTY AND GROUND GROUNDWATER EL.1.0 WATER IS UP TO HIGHEST EXPECTED GROUNDWATER BOT.EL0.5 (PI(11-2)X 0.59 X 62.4=98 LBS BOT.EL.-1.7 556 LBS PUMP>98 LBS(5.67 FACTOR) z z SANITARY SYSTEM PROFILE z > w m w� 2 N.T.S m ag me =¢ OPEN DISCHARGE PUMP TO DURAFIBER ACCESS LID OBTAIN GRAB SAMPLES DURAF W/RG24 SAFETY ORENCO EXTERNAL SPLICE GRAT24 GRADE BOX SBEX1-4 1}•LATERAL PUMP BASIN DISCHARGE ASSEMBLY 2-Xl?REDUCER(TYP) MODEL PB2SIN FIV125 W/DRAIN HOLE AND BALL VALVE 2°FROM OWTS � J_ i Q TO 2'HEADER I j 4"PLUG AT GRADE DRAINFIELQ (7YP) w FORCLEANOUT FROM DE OWTS~ 5 HEADER DETAIL ON 2 N.T.S 4"PVC 4"X 45°BEND 4"PVC WYE ORENCO DISCHARGE Ol PUMP MODEL PF200511 °a z v U w 4"PVC "' > MIN SLOPE @'PER FLOW w --_±_,.'�. -=�L.-�,�'✓t - y-•`-'�'" '" �{ -36•-.- CAST-IN-PLACE CONCRETE U z i PROVIDE 6°SAND&GRAVEL I DEADMAN POURED PRIOR Z c� BEDDING UNDER CLEANOUT TOP PUMP BASIN INSTALLATION PENETRATE PUMP BASIN 3°INTO DEADMAN = w z u s CLEANOUT DETAIL a PUMP BASIN W ��z H 2 N.T.S 2 N.T.S 2'WIDE X 10'LONG �"( N W° =° 3/8'WIRE ROPE WITH(2)3/8 CABLE CLAMP(TYP) z NYLON STRAP o� w ESTABLISH VEGETATIVE COVER AND n w a TOPSOIL GRADE TO DRAIN NATIVE BACKFILL i 5/8"X 9°TURNBUCKLE w _ (TYP OF 2 MIN.PER TANK) z W U 1.4- a 3/8'WIRE ROPE WITH o o EMBEDDED EYEHOOK (2)3/8 CABLE CLAMP M••�� p e (TYP OF 4) (TYP) 2'UNDISTURBED ,� _ _ -"_•`•' SOIL 36'TRENCH WIDTH _ .} DETAIL A NOTES: DETAIL B NOTES: CONCRETE ANCHOR g=1 Z'n 1. OUICK4 STANDARD CHAMBER(LEFT)AND°UICK4 STANDARD MULTIPORT ENDCAP(RIGHT) 1. FLUSHING MECHANISM WITH VALVE BOX DETAIL SHOWN SIZED PER FUJI CLEAN 6°MIN BED OF COMPACTED GRAVEL w�y SHOWN 2. INSULATE BOX AS NECESSARY INSTALLATION MANUAL BENEATH TANKS AND ANCHORS j z o m 2. PRESSURE PIPE SIZE PER DESIGN ORIFICES AT 12 O'CLOCK,WITH FIRST AND LAST ORIFICE 3. PVC FEMALE ADAPTOR WITH A MALE THREADED CAP 3 O AT 6 O'CLOCK TO DRAIN THE PIPE(ADD EROSION PROTECTION SUCH AS PATIO BLOCK) 4. PIPE SIZES PER PLAN 5. INSTALL 90°SWEEP FITTING OR 2-05°BENDS,NO ELBOWS o 1 W DEADMAN CAPACITY USING SIMPLIFIED SOIL COLUMN APPROACH y p PRESSURE PIPE DRILL HOLE USING IDENTIFIED FACTORS U L-I?LOCATIONS ON END CAP n MODEL DEADMEN(EA) f' DEADMAN NET RESTRAINT U r w e , DIMENSIONS PROVIDED(LBS) 00 Lo CEN5/CE5/CE7 2 8'X 18"X 8° 22,200 00 O O CEN710E10 2 8'X 18'X 8' 26,232 = CEN10/CE14 2 8'X 18,X 8° 29,320 DETAIL A END CAP GEN1410E21 2 10'X18'X8' 39,065 ch INFILTRATOR CHAMBER CEN2110E30 2 12'X 18'X 8' 51,235 u- (ANY MODEL) N ° DETAIL B w s INFILTRATOR QUICK 4 PLUS STANDARD 7 FUJI CLEAN TIE DOWN DETAIL 2 N.T.S 2 N.T.S U) z 110 � � LJ _ �o _ z DO o wU 0Gn o a Hz cn 120V AC,10,60 HZ,20-AMP POWER SUPPLY. HIGH WATER ALARM WIRING #12-AWG WITH GND IN PVC CONDUIT. K c AS PER MFGR.IN CONDUIT. MAIN SERVICE o PANEL w y o z z i o CONTROL F m o z PANEL o CHAMBER VOLUME(GAL) o SCUM BAFFLE B 1 SEDIMENTATION CHAMBER 277 FUJICLEAN UNIT 7 10}° 2 ANAEROBIC FILTRATION CHAMBER 278 (SINGLE BLOWER CONNECTRIOIN E 2'-7}" 2 3 AEROBIC CONTACT FILTRATION CHAMBER 127 RECIRCULATION 4 STORAGE CHAMBER 63 U)_I AIR LIFT PUMP 5 DISINFECTION CHAMBER 4 HARDWIRE _ O3 DISINFECTION GROUND ROD CYLINDER(OPTIONAL) TOTAL VOLUME 749 — Q 4"INLET IPE 4"OUTLET PIPE W SPECIFICATIONS A 4' A ANAEROBIC MEDIA PP I PE FILLING RATE 32% 5 = BOARD TYPE AEROBIC MEDIA PVC/PP/PE FILLING RATE 16% Z 5 AEROBIC MEDIA PP/PE FILLING RATE 57% FUJIMAC BLOWER 0 80RII-20ORII EFFLUENT BLOWER 2.8 CFM -- INLET BAF LE —a O AIR LIFT PUMP TANK FRP 0 O PIPING PVC/PP/PE "a z ACCESS COVERS PLASTIC/CAST IRON s ELECTRICAL ONE LINE DIAGRAM Z W > w DISINFECTANT(OPTIONAL) CHLORINE TABLETS N.T.S 3 wU RECIRCULATION PIPE L FLOW BAFFLE 1/2"AIR INTAKE Z 'Zw o FLOW OPENING(TYP.) (CLEANING OPENING) 8 w g ? 0 4.87• PROVIDE SECONDARY PLAN VIEW O SAFETY COVERS(TYP) b CLEAN OUT MUST BE INSTALLED /'� 5 y z N w 24"ACCESS COVER TO PROVIDE ACCESS TO THE H F 20'ACCESS COVER(TYP) 20'ACCESS COVER(TYP) 24"ACCESS COVER(TYP) DISINFECTION ADAPTER FROM ABOVE(TYP) 3°z CYLINDER(OPTIONAL) z 6.24' FLOW OPENING w o z z z BOARD TYPE _ CONTACT MEDIA o WL J OUTLET SOLVENT WELDED TO 4'LONG STUB OF 4•SCHEDULE 40 PIP 0 CONNECTED TO FUJI CLEAN CEN UNIT(TYP) 4 Q m TnO O 90 DEGREE LATERAL3INLE 'TOP VIEW O O4 - RECIRCULATION PORT ADAPTER ALL PORT O ASSEMBLY ARE4"OPENINGS 7.03' �s Z`° PLAN VIEW 55 W,z J .23' Wojm 1 Z z O N EXTRA INLET CAPPED .1_ 77 o Y U VIA 4'SCHEDULE 40 1.97° d Y 8 w O O 3 ADAPTER 8 PLUG(TYP) U L LL ' AEROBIC MEDIA 4.7• 0 k o_ 7. 4.3' F- 00 Lo 00 AERATION ASSEMBLY M SECTION A-A VIEW SECTION B-B VIEW SIDE VIEW C0 a FUJI CLEAN CEN-5 DETAIL /i-o*"N FUJICLEAN INLET ADAPTER DETAIL w co O 3 N.T.S 3 N.T.S W 2 U) NOTES Unauthorized alteration or addition to this survey is a violation of section 7209, subdivision 2, of the New York 1. FIELD WORK WAS CONDUCTED JUNE 2026 BY State Education Law. Copies of this ISLANDWIDE ENGINEERING & LAND SURVEYING DPC AND HEIDECKER LAND SURVEYING survey map not bearing the land ALL MEASUREMENTS WERE TAKEN ON THE GROUND. surveyors inked or embossed seal shall 2. PROPERTY LINES, BEARINGS, AND NORTH ARROW not be considered to be a valid copy. ARE BASED UPON THE FOLLOWING: LIBER 13027-PAGE 984 3. TIE LINES BASED ON MEAN HIGH WATER (MHW)= 0.9' IN NAVD88 DATUM, AS PER NOA REFERENCES AND BENCHMARKS. 4. UNDERGROUND UTILITY LINES ARE NOT SHOWN. PRIOR TO CONSTRUCTION THE CONTRACTOR SHALL CALL "DIG SAFELY NEW YORK" AT 811 AND HAVE ALL UTILITY LOCATIONS MARKED ON THE GROUND. 5. BUILDING TIES SHOWN ARE BASED UPON THE SIDING OF THE STRUCTURE AND ARE SHOWN FORPURPOSES V THEY SHOULD USED TO ISETLPROPERTY LINES,r FENCES, BUILDING T BE ADDITIONS, ETC. 6. THIS IS NOT A TITLE SURVEY. 7. THIS SURVEY WAS MADE WITHOUT THE BENEFIT OF A TITLE REPORT AND IS SUBJECT TO ANY STATE OF l `* FACTS A FULL AND CURRENT TITLE REPORT MAY REVEAL. 3.6 8. ELEVATIONS ABOVE THE MEAN LOW WATER LINE Q + 4, G N OFLy1988 (NAVD 88)THE AND RARETH ABASED UPON TGPS ICAL DATUM � AQ�Oo�O OBSERVATIONS PERFORMED BY HEIDECKER LAND _ A ?��JP g�oGM ro 4.1 2 8' SURVEYING, PLLC. r / 9. FLOOD LINES AS PER FEMA FLOOD INSURANCE ♦ `30 g FRAME RATE MAP (FIRM) #36103CO482H, REVISED SEPTEMBER 3.7 / GARAGE 25, 2009. (� ,+ 1000� ��.3 4.4 3.3 1 QP��FG G��g O l>� P�o01 t1P� DRIVEWAY CONCRETE N 4,�ONE APRON n ticl N 4.3 4.5 N 4.7 R� w 0.6E r, G�GJ 4.6 0 D FRAME Z COTTA E/ /� ���g�G 5.1 m y GARAGE OF�G o y r, FFL=6.7' Z m u' Z w GARAGE=4.7' ^^\\p p n 4.7 VQ m u b Wp W ZOO �= O m Ltd 4.7 OVERED 4.70 r ` a L a tL PORCH �o O 4.8 �O n o O o PROPAN SEPTOIC x O� A ~ o, TANKS 00 5.0' t C QET 11 C OVER COVER 5.0 O Q N a O o r f W p 5.1 5.2 O GRASS 4 9 Q m = o PROPANE O UG v E 4 o TANKS 91 4.9 STONES 5.1 �Q / �O 5.0 Q 5.2 rn 5.3 13 2 QQ OQ ` RESIDENCE 5.3 / (PAVERWD FRAME PATIO / 5i.4 .3�� 2 N/ /,6 rq SEPTIC / - COVER X p 85 o WDSIFRAME rn QQa 5.7 o VE 3.3 RESDENCE �N m OD ZONE 5.8 FFIL=7.3 I ' / O AC 6.1 � (0- #4025 WD FRAME ROER RESIDENCE 5 COVERED N g0 PORCH RR N. 26.2 X 6.4 6.9 T ,;a 6.3 6.8 6.7 s" Rp�R 2.4 2.3 6.3 ALUMI STA S SAND a g O ° 2.4 Z BOULDER GROIN � ,I NAVD88) NOW OR FORMERLY OF 93 MHw l o �i.r,�,' NANNETTE M AUTERI LIVING TRUST 0 ,�l �'0 W (S 81'49'15" E & ROBERT P AUTERI LIVING TRUST S 86 20+ 01E) 32.38' TIE) SECTION 123.00-BLOCK 05.00-TAX LOT 031.000 LIBER 13027-PAGE 984 AREA= 10,970 SQ FT. (0.252 ACRES) 0 10 20 30 METERS FEET 0 20 40 60 80 GRAPHIC SCALE 1" = 20' OF N EoY0� ISLANDWIDE I LAND SURVEYING G �0 CIVIL ENGINEERING-SITE PLANNING-SURVEYING S � O 280 MAIN STREET,SUITE 1 " FARMINGDALE,NY 11735 TELE.(631)-820-0296 l/ N °� DATE: SHEETNO 050-1 �y TOPOGRAPHIC/BOUNDARY SURVEY UNE 25,2026 SECTION 123-BLOCK 5-TAX LOT 31 of L AND 5 DRAWN BY:B D. #3885 CAMP MINEOLA ROAD Elz JOHN CAD HEIDECKER N.Y. STATE LAND SURVEYOR LIC. 050719 MATTITUCK,TOWN OF SOUTHOLD CHK 8Y:J.H. SCALE:r-=29 SUFFOLK COUNTY,NEW YORK