Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
41681-Z
�o��of souryO`o Town of Southold * * P.O. Box 1179 >d 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 47243 Date: 07/27/2026 THIS CERTIFIES that the building IN GROUND POOL Location of Property: 1795 Central Dr Mattituck, NY 11952 Sec/Block/Lot: 106.4-3 0.2 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 05/23/2017 Pursuant to which Building Permit No. 41681 and dated: 05/30/2017 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Accessory in-ground swimming pool with spa, fenced to code, as applied for per ZBA#8094 dated 4/16/2026. The certificate is issued to: Bill Livanos, Christina Livanos Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 41681 12/2/2024 PLUMBERS CERTIFICATION: ut ed ignature ��oFso�lya TOWN OF SOUTHOLD BUILDING DEPARTMENT • SOUTHOLD, NY BUILDING PERMIT RENEWED (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 41681 Date: 05/30/2017 Permission is hereby granted to: Renewal Date: 06/17/2026 Bill Livanos 54 Wrights Mill Rd Armonk, NY 10504 To: construct an in-ground swimming pool as applied for per ZBA approval Premises Located at: 1795 Central Dr, Mattituck, NY 11952 SCTM# 106.4-30.2 Pursuant to application dated 05/23/2017 and approved by the Building Inspector. To expire on 06/16/2028. Contractors: Fees: Renewal Fee $200.00 Total 200.00 Building Inspector o�SOFFn�c TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 41681 Date: 5/30/2017 Permission is hereby granted to: Livanos, Bill & Christina 54 Wrights Mill Rd Armonk, NY 10504 To: construct an in-ground swimming pool as applied for per ZBA approval At premises located at: 1795 Central Dr, Mattituck SCTM # 473889 Sec/Block/Lot# 106.-1-30.2 Pursuant to application dated 5/23/2017 and approved by the Building Inspector. To expire on 11/29/2018. Fees: IN-GROUND SWIMMING POOL $250.00 CO - SWIMMING POOL $50.00 Tot $300.00 Building Inspector *pF SOUT�,�I 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 co • Q Southold,NY 1 1971-0959 �Q 01ymUtiff N,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Bill Llvanos Address: 1795 Central Dr City: Mattituck St: NY Zip: 11952 Building Permit#: 41681 Section: 106 Block: 1 Lot: 30.2 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Modern Electric East License No: 4253ME SITE DETAILS Office Use Only Indoor F- Basement r Service (— Solar F Outdoor W, 1st Floor r Pool Fy-' Spa W Renovation r 2nd Floor F Hot Tub I— Generator F Survey Attic nF Garage ri Battery Storage El INVENTORY Service 1 ph F Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph r Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Other Equipment: Intellicenter Pool Panel, Pump 220GFI(2), Salt Generator, Lights 120GFI, Waterbond Ionizer Notes: Pool & Spa Inspector Signature: X Date: December 2, 2024 Sean Devlin Electrical Inspector sean.devlinCcD_town.southold.ny.us 1795CentralPoolElectric HM ENGINEERING P.C. 3 CHERRYWOOD DRIVE EAST NORTHPORT,NY 11731 TEL:516 476-5392 EMAIL:HMARNIKA@OPTONUNE.NET May 18, 2017 Town of Southold Building Department Town Hall Southold,NY 11971 Dear'Sir/Madam: This is to certify that the drainage facilities to be used exclusively for the construction of a swimming pool on the premises of. Livanos 1795 Central Drive Mattituck,N.Y. 11952 will not require draining because the pool is of gunite construction. The pool water will be continuously recirculated through the filter and will be reused from year to.year. The drainage from the filter backwash is nominal and will not interfere with the public water supply, the existing sanitary facilities or.public highways.. Sincerely, HM E. eering P.C. e Marnika P.E. �OF SOUj ��ycourm a� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 1 NSPECTION [/] FOUNDATION 1ST r [ ] ROUGH PLEIG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: DATE INSPECTOR OF SOUIyOIo U(J 1 1� �f I`.f f # T iCI OF SOUTH OLDI BUILDING DEPT. cou 631-765-1802 INSPECTION ' [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE &CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ] ELECTRICAL (ROUGH) ELECTRICAL'(FINAL) [ ] CODE VIOLATION ] PRE C/O [ ] RENTAL . , REMARKS: 1 DATE l INSPECTOR oe souryO� # TOWN OF SOUTHOLD BUILDING DEPT. cou 631-765-1802 $� INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] .R GH PLBG. [ ] FOUNDATION 2ND [ ] SULA IOI�VCAULKING [ ] FRAMING/STRAPPING- [ FINAL t1e�t/ [ ] FIREPLACE_& CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] 'CODE,VIOLATIO [.. ] PRE C/O [ ] RENTAL R ARKS: �✓ L IJU Vet Lc� l DATE �)A/1 INSPECTO FIELD INSPECTION REPORT DATE COMMENTS ..... -------- FOUNDATION (IST) .......... Of t -----------------t-------------------- -------- ...... .................... FOUNDATION (2ND), ROUGH FRAMING & PLUMBING .......................... ce INSULATION PER N. Y. STATE ENERGY CODE —---------- --- ............ FINAL C% ADDITIONAL COMMENTS -------------------- - - 0 .............. ------ rn ......... ------- ............. .......... ........... .......... ................ ...... ............ ........... ........... .......... . ...... .. A uFFal't TOWN OF SOUTHOLD—BUILDING DEPARTMENT h� �z Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone 631 765-1802 Fax 631 765-9502 htt s //www.southoldtownn . ov 'yea! ' P � ) � ) P � k� f� Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. Building Inspector: F P 3 2025 .Applicationsand.forms must be filled out in their entirety.Incomplete a0plications'will no'fbe'-accepted. Where the Applicant is not the owner,an Owner's Authorizationjorm(Page 2).sh'all be completed. "d Date: OWNER(S)OF-PROPERTY: Name: �� ], �` Vtkn0% SCTM#LY�1000- Project Address: r `t�() 5iJ6'�►m`� 1�1r1\le GIKCI ceV1'rX i� ob G� , t Y Phone#: q — M I—02118 Email: 81 ivaniS 3AD - l It oni Mailing Address: 1 -q'5' eeft -0 bvivi ffla+tI lucw�, CONTACT PERSON , Name: qlam Mailing Address: PO 30x �,°7 GlI' -e5 Or-t 14Y Phone#: (031 _ObL/._ 5-1q ll , Email: Yne /1 o a 6w-rar(_Kt4rdiyCC l 6�7 DESIGN PROFESSIONAL INFORMATION: Name: Chk S Mailing Address: - ri aviti esff NY ] I1�7 Phone#: �� U . ' Email: h �3 e) r(01y) CONTRACTOR INFORMATION:" Name: WorK ,r Mailing Address: Phone#: Email: DESCRIPTION"OF'PROPOSED,CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: AOther $ Will the lot be re-graded? ❑Yes XNo Will excess fill be removed from premises? ❑Yes XNo ' 1 R, PROPERTY INFORMATION, Existing use of property.S Intended use of property: �._ 1k fckxfO- SI riq ami. I ry Zone or use district In which premises is situatedc. 'Are there any covenants and restrictions with respect to this property?. [!Yet ❑No W YES,.PROVIDEA COPY: 0 Check Box After!leading: the owner/contractor/design professlonal Is responsible for all drainage and storm water Issues as provided by chapter 236 of the Town code. APPLICATION 15-HEREBY MADE to the Bullding Department far the issuance of a Bullding permit pursuant to the Building Zone ordinance of the Town of Southold,Suffolk,County,New York and othei applicable Laws,Ordlnances,or Regulations;for the construction of buildings,. additions,alterations or for removal or demolitlomis herein descrlbed:The applicant agrees to comply with all applicable laws,ordinances,building code, housing'code and regulations and to admit authorized inspector;on premises and In bullding(s)for necessary inspections.False statements made herein are punishable as a'Class:A misdemeanor pursuant to Section'210.45 of the New York State Penal law: Application Submitted By(print na e : L W/uthorized Agent ❑Owner Signature . q of Applicant; CO D.BUNCHDate:. o ary ubllc,State'ofNew York No.01 BU6185050 STATE CIF NEW YORK) Qualified In Suffolk County SS: Commission Expires April 14,2 flag COUNTY OF ) being duly sworn,de.poses'and says that(s)he.is the applicant (Name of individual signing contract)above named, (S)he is the (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,'a,nd is duly authorized to perform or,have performed the said work and to make and file this application;that ail statements cont ained tained in this.appiication are true-to the best of his/her knowledge and belief;and that the work will be performed in the mannerset forth in,the application file therewith. Sworn before me this / day of .SP Qy 20 � �` S6 win Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is.not the owner) . 1, B d ` (1.1 V Q hV,S residin' t 1 RS CE r�Z�C IZ1" v � x<Y r /, L[Mo hereby authorize M t C•-.4 I `: S r to apply on my behalf to the Town''. Southold Building pepartment for approval as described her 'In. RAt� f .., Ownerlks.Signature bate PrintCiwne6 Name 2 x BOARD MEMBERS Southold Town Hall { Leslie Kanes Weisman,Chairperson �OF so Southold 53095 Main Road-P.O.Box 1179 Southold,NY 11971-0959 Eric Dantest Office Location: Gerard P.Goehringer Town Annex/First Floor,Capital One Bank George Horning ® a� 54375 Main Road(at Youngs Avenue) Kenneth Schneider coy e� Southold,NY 11971 http://southoldtown.northfork.net ZONING BOARD OF APPEALS U ED TOWN OF SOUTHOLD 1 : 3 Tel.(631)765-1809-Fax(631)765-9064 J ) 25 2016 FINDINGS,DELIBERATIONS AND DETERMINAT 0, MEETING OF JULY 21,2016 uthold Town Cterlc ZBA FILE: 6965 NAME OF APPLICANT:Bill Livanos PROPERTY LOCATION: 1790 Summit Dr.(aka Central Drive.)Mattituck,NY SCTM# 1000-106-01-30.2 SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this application and determines that this review falls under the Type II category of the State's List of Actions, without further steps under SEQRA. SUFFOLK COUNTY ADMIMSTRATIVE CODE: Pursuant to the Suffolk County Administrative Code Sections A 14-14 to 23,referral of this application to the Suffolk County Department of Planning is not required. LWRP DETERMINATION: The relief, permit, or interpretation requested in this application is listed under the Minor Actions exempt list and is not subject to-review under Chapter 268. PROPERTY TACTS/DESCRIPTION: The subject parcel is 29,033 square feet located in the R-40 Zoning District improved with a two story single family dwelling, a detached stucco garage and stucco shed. The parcel fronts Sound Beach Drive to the north for 100 feet and has a second front yard along Summit Drive to the South for 120.06 feet. The adjoining property line to the East is 266.84 feet and the adjoining property line to the West is 261.58. The parcel is accessed via a 20 foot right of way (R.O.W) from Summit Drive. There is no improved access from Sound Beach Drive. Approximately half of the parcel (southern portion) is at elevation 100+/- (where the improvements are constructed and proposed) and the remainder has a steep down slope to Sound Beach Drive at an elevation of 20+/-, all of which shown on the survey/Site Plan prepared by Nathan Taft Corwin III, L.S. dated May 21, 2003, last revised March 15,2016"Revise House Location". BASIS OF APPLICATION: Request for Variances from Article III Section 280-15 and the Building Inspector's February 23, 2016 Amended March 24, 2016 Notice of Disapproval based on an application for building permit to demolish existing dwelling and construct a new single family dwelling and a new accessory in-ground swimming pool, at; 1) proposed accessory in-ground swimming pool in location other than the code required rear yard or front yard on waterfront property,2)proposed dwelling results in existing accessory shed in location other than rear yard or front yard on water front properties, located at 1790 Central Drive (Summit Drive), Mattituck, NY SCTM # 1000-106-1-30.2 RELIEF REQUESTED: The applicant requests.variances to; 1) locate a proposed in-ground swimming pool in a front yard where the code requires a rear yard location and 2)maintain the location of an existing stucco accessory shed which will be located partially in a side yard upon completion of new proposed dwelling, where the code requires a rear yard location. i i Page 2,July 21,2016 `Livanos,#6965 SCTM No. 1000-106-1-30.2 ADDITIONAL INFORMATION: The adjoining parcels to the East and West have similar topographies and both have an in-ground swimming pool in a front yard location(front yard to Sound Beach Drive). The existing stucco accessory shed, relative to the existing dwelling which is proposed for demolition, appears to exist partially in a side yard location. FINDINGS OF FACT/REASONS FOR.BOARD ACTION: The Zoning Board of Appeals held a public hearing on this application on July 7,2016, at which time written and oral evidence were presented. Based upon all testimony,documentation,personal inspection of the property and surrounding neighborhood,and other evidence,the Zoning Board finds the following facts to be true and relevant and makes the following findings: 1. Town Law&267-1as3)(b)(1). Grant of the variances will not produce an undesirable change in the character of the neighborhood or a detriment to nearby properties. In-ground swimming pools are common accessory structures to residential properties and the adjoining parcels to the East and West both have an in-ground swimming pool in a location similar to what the applicant proposes. The subject accessory stucco shed presently exists in its location without evidence of detriment to nearby properties. 2. '.roWn .Law 4267-b(3)(b)(2). The benefit sought by the applicant to construct an in-ground swimming pool cannot be achieved by some method, feasible for the applicant to pursue, other than an area variance.The parcel is subject to two front yards and there is no rear yard to construct an in-ground swimming pool in a conforming location. The benefit sought by the applicant cannot be achieved by some method, feasible for the applicant to pursue, other than an area variance. Placing the accessory structure in a code conforming location cannot be achieved since there is no rear yard. 3. Town Law&267-b(3)(b)(3). The variance granted herein to locate an in-ground swimming pool in a front yard location is mathematically substantial, representing 100% relief from the code. However, the subject parcel has no conforming rear yard in which to locate accessory structures and the two adjoining parcels, both similarly subject to two front yards, each have in-ground swimming pools in a front yard location. The variance granted herein to locate a stucco accessory shed partially in a side yard is mathematically substantial, representing 100%relief from the code. However, the existing stucco shed appears to presently exist partially in a side yard location and to continue this partial side yard location is not substantial. 4. Town Law 4267-bQ)(b)(4) No evidence has been submitted to suggest that a variance in this residential community will have an adverse impact on the physical or environmental conditions in the neighborhood. The applicant must comply with Chapter 236 of the Town's Storm Water Management Code. 5. Town Law &267-b(3)(b)(Q. The difficulty has been self-created. The applicant purchased the parcel after the Zoning Code was in effect and it is presumed that the applicant had actual or constructive knowledge of the limitations on the use of the parcel under the Zoning Code in effect prior to or at the time of purchase. 6. Town Law &267-b. Grant of the requested relief is the minimum action necessary and adequate to enable the applicant to enjoy the benefit of an in-ground swimming pool and existing shed location, while preserving and protecting the character of the neighborhood and the health, safety and welfare of the community. RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing test under New York Town Law 267-B, motion was offered by Member Schneider, seconded by Member Geohringer, and duly carried,to t .Pagb 3, July 21,2016 Livanos,#6965 SCTM No. 1000-106-1-30.2 GRANT the variances as applied for, and as shown on the Survey/Site Plan prepared by Nathan Taft Corwin III, L.S. dated May 21,2003, last revised March 15, 2016"Revise House Location". SUBJECT TO THE FOLLOWING CONDITIONS: 1. Installation of a de watering dry well large enough to accommodate the discharge of pool water. 2. All pool equipment must be placed in a sound proof structure. That the above conditions be written into the Building Inspector's Certificate of Occupancy, when issued. Any deviation from the survey, site plan and/or architectural drawings cited in this decision will result in delays and/or apossible denial by the Building Department of a buildingpermit, and may require a new application and public hearing before the Zoning Board of Appeals. Any deviation from the variance(s)granted herein as shown on the architectural drawings, site plan and/or survey cited above, such as alterations, extensions, or demolitions, are not authorized under this application when involving nonconformities under the zoning code. This action does not authorize or condone any current or future use, setback or other feature of the subject property that may violate the Zoning Code, other than such uses, setbacks and other features as are expressly addressed in this action. The Board reserves the right to substitute a similar design that is de minimis in nature for an alteration that does not increase the degree of nonconformity. Pursuant to Chapter 280-146(B) of the Code of the Town of Southold any variance granted by the Board of Appeals shall become null and void where a Certificate of Occupancy has not been procured, and/or a subdivision map has not been filed with the Suffolk County Clerk,within three (3)years from the date such variance was granted. The Board of Appeals may,upon written request prior to the date of expiration, grant an extension not to exceed three (3) consecutive one (1)year terms. Vote of the Board.- Ayes: Members Weisman (Chairperson), Schneider, Dantes, Horning, Goehringer. This Resolution was duly adopted(5-0). dl&4& 4 Leslie kanes Weisman, Chairperson Approved for filing / 2- 'nO16 r. BOARD MEMBERS so i Southold Town Hall Leslie Kanes Weisman, Chairperson 53095 Main Road•P.O.Box 1179 Patricia Acampora Southold,NY 11971-0959 Robert Lehnert,Jr. ci, Office Location: Nicholas Planamento • �0 Town Annex/First Floor Margaret Steinbugler Ol�'CQQ 54375 Main Road(at Youngs Avenue) Southold,NY 11971 http://southoldtownny.gov RECEIVED ZONING BOARD OF APPEALS T Pa 2:Qy Py)j_ TOWN OF SOUTHOLD APR -2-02026 Tel.(631)765-1809 Xduk Tbwn CIerk FINDINGS, DELIBERATIONS AND DETERMINATION MEETING OF APRIL 16,2026 ZBA FILE: 48094 NAME OF APPLICANT: Bill and Christina Livanos PROPERTY LOCATION: 1795 Surnmit.Drive, Mattituck NY SCTM: 1000-106-1-30.2 SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this application and determines that this review falls under the Type II category of the State's List of Actions, without further steps under SEQRA. SUFFOLK COUNTY ADMINISTRATIVE CODE: This application was not required to be referred to the Suffolk County Department of Planning under the Suffolk County Administrative Code Sections'A 14-14 to 23. LWRP DETERMINATION: The relief, permit, or interpretation requested in this application is listed under the Minor Actions.exempt list and is not subject to review under Chapter 268. PROPERTY FACTS/DESCRIPTION: The subject nonconforming 29,033 square feet, 0.667 acre, rectangular- shaped parcel located in the R-40 Zoning District, is improved with a two-story frame house,a detached garage,pool and shed(latter two improvements subject of this application).The parcel fronts Sound Beach Drive to the north for 100.00 feet and has a second front yard paralleling Summit Drive to the south for 120.06 feet. The adjoining property line to the east is 266.84 feet and the adjoining property line to the west is 261.58 feet. The parcel is accessed via a 10-foot right-of-way(no.w.)from Summit Drive,over a building lot also owned by the applicant.There is no access from Sound Beach'Drive. Approximately half of the parcel (southern portion) is at a substantial elevation 100+/- (where the improvements are constructed)and the remainder has a steep slope down to Sound Beach Drive as shown on the survey prepared by Nathan Taft Corwin III, L.S.dated May 21,2003, last revised December 20,2017,"Final Survey". BASIS OF APPLICATION: Request for Variances from Article III, Section 280-15; and the Building Inspector's October 6, 2025 Notice of Disapproval based on an application for a permit to demolish an existing dwelling and construct a new single family dwelling and install an in-ground swimming pool; at: 1)swimming pool is located in other than the code permitted rear yard; 2) existing shed is partially located in other than the code permitted rear yard; located at: 1.795 Summit Drive, Mattituck,NY. SCTM No. 1000-106-1-30.2. RELIEF REQUESTED: The applicant requests two variances,previously.granted but now expired,for the"as built" construction of an ingrourid swimming pool located in the front yard and the"as built"construction of an accessory shed located in a side yard,where the code requires both improvements to be located in a rear yard. ADDITIONAL INFORMATION:The applicant is the beneficiary of prior relief granted,permitting the construction of the improvements subject of this application, under Zoning Board of Appeals file#6965 dated July 22,,2016 for i Page 2,April 16,2026 #8094,Livanos SCTM No. 1000-106-1-30.1 which Town of Southold Building Permit#51122(replacing building permit#40827)was issued on August 23,2024 for the"demolition of an existing single family dwelling and construction of a new single family dwelling as applied for only, per SCHD approval" and Southold Town Building Permit #41681 was issued on May 30 2017 for the construction of an inground swimming pool as applied for per ZBA approval. The `as built' shed existed in its location prior to the demolition of the house and construction of a new residence. On December 30,2024,the applicant's architect wrote to the Town of Southold Zoning Board of Appeals a request for an extension to ZBA determination #6965. In a letter dated January 10, 2025, the Zoning Board of Appeals responded to the applicant's architect that as a result of not addressing the request in a timely manner ("...any variance granted by the Board of Appeals shall become null and void where a Certificate of Occupancy has not been procured within three (3) years from decision date. The Board may, upon written request, prior to the date of expiration, grant one-year extensions, not to exceed three consecutive years, all totaling six years."), to be advised that even if all extensions were granted, the variance would cease being valid on July 21, 2022, long before the extension request date. The applicant's agent is presently seeking the same relief as previously granted in order to `close out' the open building permit and obtain a Certificate of Occupancy for the improvements. No member of the public or an immediate neighbor spoke in favor of or against this application. FINDINGS OF FACT/REASONS FOR BOARD ACTION: The Zoning Board of Appeals held a public hearing on this application on April 2,2026 at which time written and oral evidence were presented. Based upon all testimony, documentation,personal inspection of the property and surrounding neighborhood,and other evidence,the Zoning Board finds the following facts to be true and relevant and makes the following findings: 1. Town Law &267-b(3)(b)(1). Grant of the variances will not produce an undesirable change in the character of the neighborhood or a detriment to nearby properties. In-ground swimming pools are common accessory structures to residential properties and the adjoining parcels to the east and west both have an in-ground swimming pool in a location similar to what the applicant proposes. The subject accessory shed presently exists in its location without evidence of detriment to nearby properties. 2. Town Law 4267-b(3)(b)(2). The benefit sought by the applicant to construct an in-ground swimming pool cannot be achieved by some method, feasible for the applicant to pursue, other than an area variance.The parcel is subject to two front yards and there is no rear yard to construct an in-ground swimming pool in a conforming location. The benefit sought by the applicant cannot be achieved by some method,feasible for the applicant to pursue,other than an area variance. Placing the accessory structure in a code conforming location cannot be achieved since there is no rear yard. 3. Town Law 4267-b(3)(b)(3). The variance granted herein to locate an in-ground swimming pool in a front yard location is mathematically substantial, representing 100% relief from the code. However, the subject parcel has no conforming rear yard in which to locate accessory structures and the two adjoining parcels,both similarly subject to two front yards, each have in-ground swimming pools in a front yard location.The variance granted herein to locate an accessory shed partially in a side yard is mathematically substantial, representing 100% relief from the code. However,the `as built' shed existed prior to the residential demolition and new construction,partially in a side yard location without a compliant location to place it. 4. Town Law 4267-b(3)(b)(4). No evidence has been submitted to suggest that a variance in this residential community will have an adverse impact on the physical or environmental conditions in the neighborhood. The applicant must comply with Chapter 236 of the Town's Storm Water Management Code. .f Ju Page 3,April 16,2026 #8094, Livanos SCTM No. 1000-106-1-30.1 5. Town Law 4267-b(3)(b)(5). The difficulty has been self-created. The applicant purchased the parcel after the Zoning Code was in effect and it is presumed that the applicant had actual or constructive knowledge of the limitations on the use of the parcel under the Zoning Code in effect prior to or at the time of purchase. 6. Town Law §267-b. Grant of the requested relief is the minimum action necessary and adequate to enable the applicant to enjoy the benefit of an inground swimming pool and accessory shed while preserving and protecting the character of the neighborhood and the health,safety and welfare`of the community. RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing test under New York Town Law 267-B, motion was offered by Member Planamento, seconded by Member Steinbugler, and duly carried, to GRANT the variances as applied for,and shown on the survey prepared by Nathan Taft Corwin 111,L.S.,last revised December 20,2017, "Final Survey". SUBJECT TO THE FOLLOWING CONDITIONS: 1. The septic system on the subject property must be approved by the Suffolk County Department of Health ' Services. 2. Pool pump equipment/mechanicals must be located a minimum of 20 feet from any property line or be contained in a shed-type enclosure with a lot line set back that is in conformance with the bulk schedule for accessory structures. 3. Drywell for pool de-watering shall be installed. 4. The applicant must- obtain a Certificate of Occupancy from the Building Department for the "as built" improvement(s) and submit same to the Office of the Zoning Board of Appeals within 6 months of this decision or submit a written request for an extension to the Board of Appeals setting forth the reason(s)why the applicant was unable to obtain a Certificate of occupancy in the time allotted. This approval shall not be deemed effective until the required conditions have been met.At the discretion of the Board of Appeals,failure to comply with the above conditions may render this decision null and void. That the above conditions be written into the Building Inspector's Certificate of Occupancy, when issued. The Board reserves the rieht to substitute a.similar design that is de minimis in nature for an alteration that does not increase the decree of nonconformity,provided de minimis relief is requested within one year of the date of this decision. Any time after one year,the Board may require a new application. , IMPORTANT LBUTS ON THE APPROVAL(S)GRANTED HEREIN Please Read Carefully Any deviation from the survey,site plan and/or architectural drawings cited in this decision, or work exceeding the scope of the relief granted herein, will result in delays and/or a possible denial by the Building Department of a building permit and/or the issuance of a Stop Work Order,and may require a new application and public hearing before the Zoning Board of Appeals. Any deviation from the variances)granted herein as shown on the architectural drawings,siteplan and/or survey cited above,such as alterations, extensions,demolitions, or demolitions exceeding the scope of the relief granted herein, are not authorized under this application when involving nonconformides under the zoning code. This action does not authorize or condone any current or future use,setback or other feature of the subject property that may violate the Zoning Code,other than such uses,setbacks and other features as are expressly addressed in this action. -v r Page 4,April 16,2026 #8094,Livanos SCTM No. 1000-106-1-30.1 TIME LIMITS ON THIS APPROVAL: Pursuant to Chapter 280-146(B)of the Code of the Town of Southold any variance granted by the Board of Appeals shall become null and void where a Certificate of Occupancy has not been procured,and/or a subdivision map has not been filed with the Suffolk County Clerk,within three(3)years from the date such variance was granted. The Board of Appeals may,upon written request prior to the date of expiration,.grant an extension not to exceed three(3)consecutive one(1) year terms.IT IS THE PROPERTY OWNER'S RESPONSIBILITY TO ENSURE COMPLIANCE WITH THE CODE REQUIRED TIME FRAME DESCRIBED HEREIN.Failure to comply in a timely manner may result in the denial by the Building Department of a Certificate of Occupancy,nullify the approved variance relief,and require a new variance application with public hearing before the Board of Appeals. s Vote of the Board: Ayes:Members Weisman(Chairperson),Planamento,Lehnert,and Steinbugler.(4-0)(Member Acampora Absent) Leslie Kanes Weisman, Chairperson Approved for filing /;7 /2026 BOARD MEMBERS �tOF SO(/jyO Southold Town Hall Leslie Kanes Weisman,Chairperson �O �O 53095 Main Road•P.O.Box 1179 Southold,NY 11971-0959 Patricia Acampora Office Location: 1 Eric Dantes �� Towi-A_n'nek/First Floor, 1 Robert Lehnert,Jr. 54375 Main Road(at ounj6Avenue) Nicholas Planamento MOW i Southold,, �oacd of Ao�;�G http://southoldtownny.govQ�1��� ZONING BOARD OF APPEALS TOWN OF SOUTHOLD January 10,2025, Tel.(631)765-1809 Charles M.Thomas,RA DENTE 206 Lincoln Street Riverhead,NY 11901 RE: Appeal#6965 Livanos ' 1790 Summit Drive,Mattituck SCTM No. 1000-106-.1-30.2 Dear Mr.Thomas; We received your correspondence,dated December 30,2024,requesting an extension of the above referenced Zoning Board of Appeals' determination dated July 21,2016,which had expired on July 21,2019. Your request was not done in a timely matter pursuant to Section 280-146(B)of the Southold Town Code and cited in the Determination,which reads,"Pursuant to the Code of the Town(280-146B)any variance granted by the Board of Appeals shall become null and void where a Certificate of Occupancy has not been procured within three(3)years from decision date. The Board may,upon written request,prior to the date of expiration,grant one-year extensions,not to exceed three consecutive years,all totaling six years." Please be advised that even if all extensions were granted,the variance would cease being valid on July 21,2022. In your correspondence,you have indicated that you are now.in the process of obtaining a Certificate of Occupancy. According to the Building Department inspection records, certification from licensed professionals is still outstanding. During our January 9,2025 Regular Meeting,the Zoning Board of Appeals denied your request. Should you wish to continue with the proposed improvements,you will need to apply for variance relief with a new application and a public hearing. Please contact our office if you have any questions or concerns. Sin f s ie K.W isman Chairperson cc: Building Department Uzi U �f r-1 Li NOV 1 -8 2024 BUILDING DEPARTMENT- Electrical lrnRe p L�r, T T57 Gym TOWN OF SOUTHOLD T k 60 _F- C* Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 4% Telephone (631) 765-1802 - FAX (631) 765-9502 ameshCcb-southoldtownny.-gov - seand(cD-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All information Required) Date: 11/18/2024 Company Name: Modern Electric East, Inc. Electrician's Name: T. Rutkowski License No.: 4253-ME Elec. email:trut299@aol.com Elec. Phone No: 516-903-7151 [D I request an email copy of Certificate of Compliance Elec. Address.: PO Box 321, Mattituck, NY 11952 JOB SITE INFORMATION (All Information Required) Name: Livanos Address: Sunniff-9five Cross Street: Central Drive Phone No.: BIdg.Permit#: i email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Wiring of Swimming Pool Square Footage: Circle All That Apply:Is job ready for inspection?: R1 YES [] NO F❑-]Rough In R1 Final Do you need a Temp Certificate?: F-1 YESFt-/] NO issued On Temp Information: (All information required) Service SizeF1 PhF-]3 Ph Size: A #Meters Old Meter# FINew Service[D Fire ReconnectoFlood Reconnect OService Reconnect Flunderground 00verhead # Underground Laterals 1 R2 F-1 H Frame D Pole Work done on Service? Y F1N Additional Information: PAYMENT DUE WITH APPLICATION %\00 P10V 1 8 BUILDING DEPARTMENT- Electrical InsR t!.o,.,, TOWN OF SOUTHOLD jJ Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 amesh(@-southoIdtownny.qov - seandasoutholdtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All information Required) Date: 11/18/2024 Company Name: Modern Electric East, Inc. Electrician's Name: T. Rutkowski License No.: 4253-ME Elec. email: trut299@aol.com Elec. Phone No: 516-903-7151 ED I request an email copy of Certificate of Compliance Elec. Address.: PO Box 321, Mattituck, NY 11952 JOB SITE INFORMATION (All Information Required) Name: Livanos Address: F-) -('J� Cross Street: Central Drive Phone No.: Bldg.Permit A U,NA email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Wiring of Swimming Pool Square Footage: Circle All That Apply:Is job ready for inspection?: RI YES [] NO F❑-]Rough In Fv Final Do you need a Temp Certificate?: F❑I YESF&-/] NO issued On Temp Information: (All information required) Service SizeF-11 PhF—]3 Ph Size: A # Meters Old Meter# FNew Servicer-I Fire Reconnect[:]Flood Reconnect Fservice Reconnect Ounderground 00verhead # Underground Laterals F]1 F-]2 F-] H Frame E] Pole Work done on Service? F]Y E]N Additional Information: PAYMENT DUE WITH APPLICATION PERMIT# Address: Switches Outlets GFI's Surface Sconces H H's UC Lts Fridge HW POOL Fans Mini Fr. WAD Panel ��, c,�ri� o/n Pump Exhaust Oven Sump Heater Trnsfmr 1. Smokes DW Generator Salt Gen. 2 I � Carbon Micro GrbDis Water Bond kGALights (��-, Heat Pucks ERV �� HOT TU T SPA Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower AC AH Hood Blower Service Amps Have Used Sub Amps Have Used Comments R . Charles M. Thomas, R.A., PLLC 206 Lincoln Street Riverhead, NY 11901 e-mail: cdthomas63&aol.com July 24, 2026 Attn: Town of Southold Building Department Re: Livanos Residence 1795 Central Drive, Mattituck BP# 41681 Tax Map: 1000-106-01-30.002 Dear John Jarski, Included in this document are the photos requested from your most recent pool inspection at the above referenced property. Thank y , Charles M. Thomas, R.A. Q JUL 2 4 2026 '1;1jSj ►®DSP `�, is 0 Kan s,d.o STOPLAWWATEIK Scott A. Russell ' cG)EI��[)EN�C SUPERVISOR r- F r f SOUTHOLD TOWN HALL-P.O_Box 1179 %apr �]' 53095 Main Road-SOUT�?OLD,NEW YORtC 11971 .0 own of Southold CHAPTER 236... ,.,STORMWATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT ) I)O1CS..,,I 9IS..:..PIZ0J1EC"I'....IlNVoLNTE .;AN:Y OF 'I'HE. .F'OLI,t3NVING: (CHECK ALL THAT APPLY) Yes No_ ;.. gA_ Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. Q'B_ Excavation or filling involving more than 200 cubic yards of material t ,�/ within:any..... parcel or arty contiguous area. t. ❑[3/C. Site prapraltoI on slopes which exceed;: 10 feet vertical rise to l .. 100:fee of l j izopt-AT distance. f, ❑ D. Site parpar::a 'Qn tutlin 100 feet of wetlands, beach, bluff or coastal ?' erosion 16; ,area. ❑ re a-ran within the one-hundred-year floodplain as depicted Q/E. Site ' A P Twat-ercau rsE a ❑ F_ Instal: tYon:of:nevsr.o� resurfaced tvorvlous surfaces of 1,000 gnare feet or more, unless prior approval:of a Stoi M.ivv-al er.Mar>agernen ; Control Plan was received by the Town and the proposal includes In-klnd replacement of impervious surfaces., -..-...___,.__:te?.�„.,..:-� #-^"-- '''...--�::::i�:-,»..a .csc;s:-.a-,tr..cr..-:�,r.:`�'�-ors--=mac -}twt;t:._.-t:`m. >`'x"` `x}z� �------^_^-""__^.y.-,='-�`".,:--::-_�_•-•••;,.»w If you answered NO to all of the questions above, STOP. Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your projec.L . _._.. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan.. J. and a completed Check List Form..to..the Buildlng Department with your.)tujj(iing Permit Application. _-�„�, S C T 1000 ate APRLICA (P NTcroperty:0iriiar' ,es iProf�ssi---r,.gcnt„Contractor,Otherl distllc( S.C.T.M. r. ry D NAME: G'} t�if�. 10 �— 7jd. ` jI �vi Section Block Lot mt�mra :K� F'OR BUILDING DEPAR"I'I ILENT USL ONLY,:,t� Contact Inrormaliam Reviewed By: I __ Date: Property Addres. / Loc3.tion of Construction Work: — �, Approved for processing Building Permit. 11iortriwater Management Control Plan Not Required. JAI- 1��'(t1�.�_ _ _ __-__,.__._ Stormwater Management Control Plan is Required, (Forward to Engineering Department for Review.) FORM ' SMCP -TOS MAY 2014 :i i1 i . CH APTER PTER 23 6 nprry GL rs Des4gn CrroEesss?nat, ,gor.,q Contractor,Other! S.C.T,M. pSUil o ! Stormwatelr..Ma.na eMent.Conirol Plan CHECK LIST. '"AME: Section Block .. 1j;,Lot z- S M C P Plan Requirements, Provide ONE copy of the Building, Permit Application;. Date The applicant must provide a Complete Explanation and/or Reason for not providing `lZ all Information that has been Required b the following Checklist! Y;,L•Kr �kr7�-- q Y g i. A Site Plan drown to scale Not Less that 60' to the incOvlUS"I' If You answered No or NA to any Item, Please Provide Justification Hercl show all of the following items: YES :NO.I NA If you need additional room for explanations, Please Provide additional Paper. ' a. Location & Description of Property Boundaries 3I b. Total Site Acreage: is l c. Existing - Natural & Man Made Features within 5001.F t of the Site Boundary as required by §236-17(cl(21 ;;� DRAINAGE INSPECTIONS ARE REQUIRED d. Test Hole Data Indicating Sail Characteristics&Depth to Toundtwater. ContaR TOS E.. ineerin at 765-1560 beforei e, Limits of Clearing..& Area of:Proposed Land Distuc6ance. i eackfll,,OR Provide En neei's Cectif ! f. Existing & Proposed Contours of the Site (M{n!rnum z*rvats) g. Location of all existing & pioposed structures, roaas . driveways, sidewalks, drainage improvements..,., util ties I h. Spot Grades & Finish Floor Elevations for all existin't� & 1P _ _ 11 proposed structures. I. Location of proposed Swimming Pool and.dischar e.rin J. Location of proposed'Soil'Stock ife Area.W. k. Location of proposed Construction Entrance/Staging Area(sl. (. Location of is ose 'concrete washout.atea(s .GS.. �+. . ITi. Location of all proposed erosion 8 sediment control measures.i' _..:. 2. Stormwater Management Control Plan must include Calculations slar�bing QNT C3l.RS that the stormwater improvements are sized to capture,store,and Crrf tlirate : Ctt E'Jimi>eii-tip; s on-site the run-off from all impervious surfaces generated by a twoi(21 inch rna# t3tt1� CAt15CUCt►Ori;En rainfall event. a Wire ac - Slit sta iI SFe 3. Details&Sectional Drawings for stormwater practices are required for:approval. Ihg Of eXpo ed�T)t� items recuir inn detalIS shall include but.not be.limited €e::` . Erosion & Sedirnent Controls. ;t I 4 l: a b. Construction Entrance & Site Access, 11- c. Inlet Drainage SI1-UCture5 (e.g.catch basins,trench dralns etc.) t d. Leaching Structures (e. . Infiltration basins,swales,etc.). ✓ I i::`iG,�!:•:L:;Ii Ca l.)I_P N711 E.ONLy''"` Additional Information is Required. Reviewed & Stormwater Management Control Plan is Not Complete, Approved By: —. o Stormwater Management Control Plan is Complete. SMCP has been approved by the Engineering Department F(DRi`V1 SVvCP ncck List -TOS MAY 2014 'i x . MAP OF CAPTAIN KIDD ESTATES FILE No. 1672 FILED JANUARY 19, 1949 ' v: o `P SITUATED AT MATTITU C K TOWN OF SOUTHOLD . SUFFOLK COUNTY, NEW YORK ` p S.C. TAX No. 1 000- 106-01 —30.2 e ` \V% SCALE 1 =30 MAY 21 , 2003 FEBRUARY 24, 2006 RE—CERTIFIED 1 IS i��� �� �� ��� // /�j j j 56 DECEMBER 22, 2015 UPDATE`SURVEY 6110 AREA = 29,033 sq. ft. 30 j ; /�i ��� i i / / / // /6yh 0.667 ac. 669 ��l yp � CERTIFIED T0: / 'yak �� �'�ti COMMONWEALTH LAND TITLE INSURANCE COMPANY 5" / < y —56 O 9�F HSBC MORTGAGE CORPORATION (USA) 88 BILL LIVANOS bo \�' _ — //Z/ /i / 90 CHRISTINA LIVANOS —92 —94 as PROPOSED LOT COVERAGE $ • X �i —96 OVER TOTAL LOT AREA = Z9,033 sq. ff. He, CL64A 0 �� 1 0pi' �Oa c°� S DE CRIPTION AREA LOT COVERAGE vEG6TWTIIDQ 3e oND $6 X ,, ::.::'::..:::;Qoy :;:.:;.;:;.:;::•::::;. :: :::P..:::::.:: .. :.: : 99.3 X':`.:.:``:;".,•:�:::=:'::::" EXIST. GARAGE 535 sq. ft. 1.9% _Xtsrl,kS Ca�e ,� WASCIO 9p :....Q...:.Q.:......::.:: :`::.::..-.. o;:::;•::•:::::;::....: 9 ::�'•. 0 S� �p EXIST. SHED 150 sq. ft. . 0.5% rG`sc` O 98 99.3 ` ......:: ::';:: r��C:;: .............: . .. ' '26 PROP. HOUSE W PORCHES 2.974 s ft. 10.2% ::, �,. ........ q h 0"J•a,._:.:,•:. :. ..............rr ,�, 97.4 6' PROP. POOL 720 s ft. 2.5% q• Oop�� p ....:' ......:. 0.:.�1.::............:�i3::.......a.:i q ?. °� 37. TOTAL PROPOSED 4,379 sq. ft. 15.1 ANC ` ..:•.... -. ::: ::° titi. °°o A � 's`.... ter' :• �:.,V. ,... k: ����, .y2•� P � � �00. �- TEST HOLE e� '" dot F c.. 6 ° 90.9 9.8 Va �@ °G 99.9x V` W�� e •�C�. F�Z� ��c��P �c QcO %b °° V . ° °/ \ S v GPI `°� J P �6•.m CO 7002x � ' 5 ti NOTES: 1. ELEVATIONS ARE REFERENCED TO AN N.A.V.D. 1988 DATUM EXISTING ELEVATIONS ARE SHOWN THUS: 80.0 EXISTING CONTOUR LINES ARE SHOWN THUS: — — —— —SD- F.FL.- FIRST FLOOR ' G.FL.- GARAGE FLOOR CSC 9/\ A T.W. - TOP OF WALL B.W. - BOTTOM OF WALL 2. MINIMUM SEPTIC TANK CAPACITIES FOR A 5 BEDROOM HOUSE IS 1,500 GALLONS. \ '' ' \�o DRAINAGE INSPECTIONS ARE REQUIRED 1 TANK; 8 DIA. 5 LIQUID DEPTH 3. MINIMUM LEACHING SYSTEM FOR A 5 BEDROOM HOUSE IS 400 sq ft SIDEWALL AREA. 98 o n 9a Contact TOS Engineering at 765-1560 before 1 POOL; 16' DEEP, 8 dia. \N� �\ o Backfill,OR Provide Engineer's Certification PROPOSED EXPANSION POOL \t1G N �a \ that the drainage has been installed to Code. PROPOSED LEACHING POOL 96 4... PROPOSED SEPTIC TANK \ ci EROSION&SEDIMENT CONTROLS 4. THE LOCATION OF WELLS AND CESSPOOLS SHOWN HEREON ARE FROM FIELD \ OBSERVATIONS AND/OR DATA OBTAINED FROM OTHERS. j0 .4 s4.s Shall include bait not be limited to: ALL HOUSES WITHIN 150' OF SUBJECT PROPERTY ARE CONNECTED TO PUBLIC WATER. 4' THERE ARE NO WELLS WITHIN 150' OF SUBJECT PROPSERTY. A. A Well maintained Construction Entrance, — 94 \94— Wire Backed Sift Fencing,stabilization& 5. EXISTING SEPTIC SYSTEM STRUCTURES SHALL BE PUMPED CLEAN AND EITHER REMOVED \ f. Seeding of exposed and/or inactive soils. OR FILLED WITH CLEAN SAND IN ACCORDANCE WITH S.C.D.H.S. STANDARDS. \ �. \ °o DRAINAGE SYSTEM CALCULATIONS: ROOF AREA: 3,000 sq. ft. \ 92; APPROVAL OF STORMWATER 3,000 sq, ft. X 0.17 = 510 cu. ft. . .. A _g2 MANAGEMENT . 510 cu. ft. / 42.2 = 12 vertical ft. of 8' dia. leaching pool required \92 d CONTR •P N -T n C PROVIDE (2) 8' dia. X 8' high STORM DRAIN POOLS \ °' + Date: Pt 6 PROPOSED 8' DIA. X 8' DEEP DRYWELLS FOR ROOF RUN—OFF ARE SHOWN THUS: oO o Approyod b' .a DRIVEWAY AREA: 1,700 sq. ft. 1,700 sq. ft. X 0.17 = 289 cu. ft. x _EDGE aF pAVEME� 289 cu. ft. / 42.2 = 7 vertical ft. of 8' dia. leaching pool required PROVIDE (1) 8' dia. X 8' high STORM DRAIN POOL +x PROPOSED 8' DIA. X 8' DEEP DRYWELL FOR DRIVEWAY RUN—OFF ARE SHOWN THUS: O s x x �T�l� SPREPARED TANDARDSIFOR TORD 115 TF1I�MINIM15HED 1 �1 FB THEOR SUCH US S. A BBiiPT IFr N9 TER 1N STREET TITLE ASSOC oN: A ,� , TEST HOLE DATA PueuC (TEST HOLE DUG BY NATHAN CORWIN L.S. ON DECEMBER 22, 2015) ZI 0' DARK BROWN LOAMY SAND SM 2.5' PALE BROWN FINE SAND SP N.Y.S. Lic. .No. 50457 14' UNAUTHORIZED ALTERATION TI ADDITION Nathan Taft Corwin TO THIS SURVEY IS A VIOLATION OF SECTION 7209 OF THE NEW YORK STATE PALE BROWN AND SM � EDUCATION LAW. Land Surveyor - BROWN SILTY SAND COPIES OF THIS SURVEY MAP NOT BEARING THE LAND SURVEYOR'S INKED SEAL OR EMBOSSED SEAL SHALL NOT BE CONSIDERED 23' TO BE A VALID TRUE COPY. CERTIFICATIONS INDICATED HEREON SHALL RUN Successor To: Stanley J. Isaksen, Jr. L.S. ONLY TO THE PERSON FOR WHOM THE SURVEY Joseph A. Ingegno L.S. PALE BROWN FINE SAND SP IS PREPARED, AND ON HIS BEHALF TO THE TITLE COMPANY. GOVERNMENTAL AGENCY AND Title Surveys — Subdivisions — Site Plans — Construction Layout LENDING INSTITUTION LISTED HEREON, AND TO THE ASSIGNEES OF THE LENDING INSTI- PHONE (631)JZ7-2090 FOX (631)727-1727 TI ITIMI (`rDTlrl!`�rin�ic •or .InT roll.lcrro�o�r Y� N SURVEY OF e N in P O LOT 5 8c P O LOT 6 MAP OF 4' •4 CAPTA IN KIDD ESTATES FILE No. 1672 FILED JANUARY 19, 1949 SIT UA TED A T �Q V� ,�� MATTITUCK TOWN OF SOUTHOLD a.. SUFFOLK COUNTY, NEW YORK S.C. TAX No. 1000- 106-01 -30.2 SCALE 1 "=30' \ MAY 21 , 2003 \ \ FEBRUARY 24, 2006 RE—CERTIFIED \ DECEMBER 22 2015 UPDATE SURVEY ` \ MARCH 15, 2016 REVISE HOUSE LOCATION \ MAY 31, 2016 RELOCATE PROPOSED WATER LINE AUGUST 29, 2016 FOUNDATION LOCATION ` \ DECEMBER 20, 2017 FINAL SURVEY AREA = 29,033 sq. ft. \ 0 100`� ��\�� 0.667 ac. \ s \ CERTIFIED TO: ���'•\\ �� COMMONWEALTH LAND TITLE INSURANCE COMPANY HSBC MORTGAGE CORPORATION (USA) BILL CHRIST NAN�IVANOS •16 \\ G Q Q ye 0 e�� k� Asa 31G e nse4� °ws 05 O � �'` /�'� sees '• '. `�,' 65 S`j` O tiPhi gk F e ° �E C°�G � (� 17 �' n � 6� , P iA j � ,� �, 9�tn yt" PyE,• SEPTIC SYSTEM TIE MEASUREMENTS <� r`$9 °F G\�` '�° 300 y' HOUSE HOUSE5� ` °y5`r�' ��,,k CORNER �A CORNER© °� � \ ty� • • I� R=160.69' SEPTIC TANK °o�Fy°° i' 3 L=178.90 COVER 15.5 33 \\ LEACHING POOL COVER 27.5' 26.5' •sue J���� / 6Q, o �. �O ^'S all <0 16 T\ 4 Gy vVw oil \. C> :, CAN c;`>.:•. \ '•ri;::?:fir:.`:. \ .O0. G�ON� 'a • ' 4 .EDGE OF Pp` i PREPARED IN ACCORDANCE WITH THE MINIMUM RIVE STANDARDS FOR TITLE SURVEYS AS ESTABLISHED IT 1, BY THE H USE AND APPROVED AND ADOPTED FOR SUCH USE B�','�}�g �'p K STATE LAND S S?REET TITLE ASSOC 11ON OF NEW w f�A BLIC WATER IN Y 0)� Crw r,• t�r rI>✓ ; . 1 a 111 n{y N.Y.S. Lic. No. 50467 UNAUTHORIZED ALTERATION ADDITION Taft Corwin I I I TO THIS SURVEY IS A VIOLATION OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW. Land Surveyor COPIES OF THIS SURVEY MAP NOT BEARING THE LAND SURVEYOR'S INKED SEAL OR EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. CERTIFICATIONS INDICATED HEREON SHALL RUN Successor To: Stanley J. Isaksen, Jr. L.S. ONLY TO THE PERSON FOR WHOM THE SURVEY Joseph A. Ingegno L.S. IS PREPARED, AND ON HIS BEHALF TO THE TITLE COMPANY, GOVERNMENTAL AGENCY AND Title Surveys — Subdivisions — Site Plans — Construction Layout LENDING INSTITUTION LISTED HEREON, AND TO THE ASSIGNEES OF THE LENDING IPHONE (631)727-2090 Fax (631)727-1727 TUITION. CERTIFICATIONS ARE NOT TRANSFERABLE. THE EXISTENCE OF RIGHT OF WAYS OFFICES LOCATED AT MAILING ADDRESS AND/OR EASEMENTS OF RECORD, IF 1586 Main Road P.O. Box 16 ANY, NOT SHOWN ARE NOT GUARANTEED. Jamesport, New York 11947 Jamesport, New York 11947 23-187G 6fMMEDjj,ATELY7 cbDE ENCLOSE POOL TO. N CoMp�ETJO APPROVED AS NOTED U5r--FPO 0R5-"WA-f ERN DATESia -1 B.,q ca ��y-?i v I i-H L L C;0�)�i S OF 7- NOTAY BUILDING DEP-L,RI MENT AT & TOWN CODES 765-1802 8AM TO 4PM FOR THE AS REO D AND CONDITIONS OF FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED SSOLITI HOLD M�1,Ni ZBA FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING �G BOARD 3. INSULATION USTHS 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. 01 'kppic �FUL , Is k3br- 01 0�Rj If r .y r POOL NOTES: 1.POOL AND PROPERTY TO CONFORM TO 2015 IRC&NYS 2016 UNIFORM CODE SUPPLEMENT SECTION R326 AND CODE OF THE TOWN ALL CORNERS FORMED OF SOUTHOLD. BY INTERSECTION OF 2.POOL SHALL CONFORM TO ANSI/NSPI STANDARDS R326.3.1. PUMP SUCTION SKIMMER WALLS AND FLOOR POOL DECK TO 12" FILTER SHALL BE ROUNDED SLOPE AWAY FROM 3.SECTION R326.7 POOL ALARM REQUIRED. POOL MIN. WATER LEVEL 3' 4.ENTRAPMENT PROTECTION REQUIRED SECTION R326.6. BINOSE DOWN FROM TOP OF 40' COPING POOL 5.POOL SHALL COMPLY WITH BARRIER REQUIREMENTS SECTION R326.5. 4 4i 6.POOL SHALL COMPLY WITH INTERNATIONAL ENERGY (3) #3 BARS 6" FROST PROOF TILE BAND CONSERVATION CODE SECTION R403.10: LINE OF BENCH CONTINOUS GRADE .. :: POOLS AND PERMANENT SPA ENERGY CONSUMPTION(MANDATORY). COPING BEAM Ties 2 o c ;-` ::" 8 X 8 SPA PNEUMATICALLY APPLIED CONCRETE SECTION R403.10.1 HEATERS E s PC�L (SEE DETAIL ON ' ... SECTION R403.10.2 TIMESWITCHES SHEET 2 OF 3) #3 BARS O 12" O.C. a' '• SECTION R403.10.3 COVERS Ate SPA VERTICAL AND HORIZONTAL !' '•' RETURN 7.THE DESIGN IS BASED ON A DRAINAGE SOIL WITH<10%SILT. W14M MAF93LE DUST �T. _, DIRECTIONAL INLET 2.5, GROUND WATER SHALL NOT EXIST WITHIN LIMITS OF THE (MIN.) THFX)UGH= WALL THICKNESS i_., EXCAVATION.IF GROUND WATER EXISTS WITHIN 6'BELOW GRADE ew B.P. 16' VARIES 6" TO . SPECIAL DEWATERING FACILITIES WILL BE REQUIRED.WATER DISPOSAL DUAL MAIN DRAINS 22' STAIRS SHALL BE 6"(MIN.)) •.; r., WHITE MARBLE DUST FINISH IS LIMITED TO OWNER'S PROPERTY. WITH STRAINER (VGB 00, OF NON-SUP :' •; : RADIUS VARIES 8.NO SURCHARGE ALLOWED WITHIN 4'OF SHALLOW END AND 6'OF SAFETY ACT ,00 DESIGN ' 1' RADIUS ROUNDED CORNERS DEEP END. APPROVED DRAINS) g3 BARS ®s' O.C. IN RADIUS + (SHALLOW END) 9. THE PNEUMATICALLY APPLIED CONCRETE(GUNITE)SHALL BE 4,000 AND VERTICAL WHEN WALL i....:.' > 5.5' (MAX.) RADIUS ROUNDED PSI @ 28 DAYS. HEIGHT EXCEEDS 5' i CORNERS (DEEP END) (ALTERNATE BARS) ` 10.REINFORCING STEEL SHALL BE INTERMEDIATE GRADE BILLET STEEL !+ y3 REBARS - 12' ON CENTER EACH WAY WITH A MINIMUM LAP OF 30 BAR DIAMETERS. 6' x 12' (FLOOR) 11.REBAR SHALL BE 2"MIN.CLEAR TO EARTH. SUNDECK +`d;.' < 12.POOL WATER SUPPLY BY OWNERS GARDEN HOSE.POOL TO BE '•' KEPT FULL DURING FREEZING WEATHER.PUMP CAPACITY TO BE SUFFICIENT TO EMPTY POOL IN 24 HOURS. 13.LOCATION OF PROPOSED SWIMMING POOLAND POOL 36' 6•5. �6"SLAB EQUIPMENT BY OTHERS AND SHALL COMPLY WITH ALL LOCAL ZONING REQUIREMENTS. TYPICAL WALL SECTION 14.ALL DRAIN COVERS TO MEET ALL REQUIREMENTS OF THE VIRGINIA 3" TO 6" CLEARANCE POOL PLAN NOT TO SCALE GRAEME BAKER(VGB)POOL AND SPA SAFETY ACT. BETWEEN POOL NOT TO SCALE 15. NO DIVING EQUIPMENT PERMITTED. LADDER AND WALL 16.CONTRACTOR SHALL VERIFY SOIL BEARING LOADS PRIOR TO INSTALLATION OF POOL. 17.SLOPE PATIO SURFACE 1/4"PER FOOT AWAY FROM POOL. FILL SPOUT AS SKIMMER (TYP.) INLET (TYP.) QUANTITY 18. THIS PLAN IS FOR CONSTRUCTION ON PROPERTY AT 1795 CENTRAL REQUIRED QUANTITY AND AND LOCATION BY DRIVE MATTITUCK,N.Y.11952 ONLY. LOCATION BY POOL POOL CONTRACTOR PROVIDE SEALING 19.HM ENGINEERING,P.C.SHALL NOT BE RESPONSIBLE FOR BULLNOSE COPING CONTRACTOR AT DECK/ COPING CONSTRUCTION MEANS,METHODS,TECHNIQUES OR PROCEDURES MIR.) UTILIZED BY THE CONTRACTOR,NOR FOR THE SAFETY OF THE PUBLIC LADDER WATER LEVEL ( �) OR CONTRACTOR'S EMPLOYEES,OR FOR THE FAILURE OF THE CONTRACTOR TO CARRY OUT THE WORK IN ACCORDANCE WITH THIS -- - ------- -------- --- -- — PLAN. O O 3.5' GRADE BEAM UNDERWATER 6.0' (TYP.)LIGHT (OPTIONAL) 1 1/2" TO WASTE HAIR & LINT STRAINER 6" THICK PUMP CONCRETE (TYP.) FILTER AUTO SKIMMER IDS 36' IDS DUAL MAIN DRAIN WITH L FOR POOLS CONSTRUCTED ON VIRGIN PREPARED FOR: DUAL MAIN DRAIN HYDROSTATIC VALVE AND SOIL, COMPACT BASE TO 95% MODIFIED POOL WITH HYDROSTATIC COLLECTOR TUBE IN POOL PROFILE LIVANOS BACK TO VALVE AND GRAVEL BASE NOT TO SCALE BACKFILL MATERIAL, POOL POOLS NCONTRACT RSTRUCTED N 1795 CENTRAL DRIVE POOL COLLECTOR BE IN TO INSTALL 6" COMPACTED GRAVEL BASE MATTITLICK, N.Y. 11952 SCHEMATIC PIPING ARRANGEMENT NOT TO SCALE NOTE: DATE: 0 511 9/2 01 7 0 C P. SCALE: AS SHOWN > . THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF HM ENGINEERING P.C..UNAUTHORIZED ���/`� FTel: HM ENGINEERING, SHEET: 1 OF 3 ALTERATIONS OR ADDITIONS TO THESE DOCUMENTS ARE A VIOLATION OF SECTION 7209 OF THE NEW YORK STATE 3 CHERRYWOOD DRIVE.EAST NORTHPORT,NY 11731 EDUCATION LAW.INFRINGEMENTS WILL BE PROSECUTED. 516)476-5392 Fax:(631)980-7671 www.hmarnika@optonline.net RESIDENTIAL GUNITE SWIMMING POOL PLAN 4 C " SKIMMER PROVIDE 6" MIN. 16 (8 RETURNS) (NP,) FROST PROOF TILE 18" (2 RETURNS) UNDER COPING 1 1/2" (8) RETURN JETS 8' c v 16" SEAT 0 22" °0 o 42"! 12" (3) #3 REBAR CONTINOUS GRADE BEAM ALL AROUND TIES 12" O.C. #3 REBAR 12" O.C. EACH WAY 12" X 12"9" DIA. GRATE GRATE as 6" e' X 8' SPA DUAL MAIN DRAIN WITH 1 1/2" SUCTION " (SEE SECTION HYDROSTATIC VALVES TO FILTER 3" SUCTION AND COLLECTOR TUBES GRADE BEAM DETAIL FOR JETS THIS SHEET) OVER GRAVEL BASE NOT TO SCALE SPA PLAN SPA NOTES: SPA SECTION 1.SPA SHALL BE GUNITE CONSTRUCTION. SCALE: 1:4 NOT TO SCALE 2.POOL FLOOR-#3 BARS 12"O.C.SPACING EACH WAY. 3.POOL SIDES-12"O.C.SPACING EACH WAY. 4.POOL INTERIOR SHALL BE LIGHT COLOR MARBLE DUST. 5.A MINIMUM 6"COVE RADIUS BETWEEN FLOORS AND WALLS. 1 1/2" TO WASTE 6.ALL DRAIN COVERS TO MEET ALL REQUIREMENTS OF THE HAIR & LINT STRAINER VIRGINIA GRAEME BAKER(VGB)POOL AND SPA SAFETY ACT. PUMP FILTER AUTO SKIMMER DUAL MAIN DRAIN POOL WITH HYDROSTATIC BACK TO RELIEF VALVE AND POOL COLLECTOR TUBE IN GRAVEL BASE SCHEMATIC PIPING ARRANGEMENT NOT TO SCALE PREPARED FOR: LIVANOS 1795 CENTRAL DRIVE MATTITUCK, N.Y. 11952 0171 0 DATE: 0 611 912 01 7 NOTE: HM ENGINEERING P.C. SCALE: AS SHOWN THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF HM ENGINEERING P.C..UNAUTHORIZED SHEET: 2 OF 3 ALTERATIONS OR ADDITIONS TO THESE DOCUMENTS ARE A VIOLATION OF SECTION 7209 OF THE NEW YORK STATE 3 CHERRYWOOD DRIVE EAST NORTHPORT,NY 11731 EDUCATION LAW.INFRINGEMENTS WILL BE PROSECUTED. FTel: 516)476-5392 Fax:(631)980-7671 www.hmarnika@optonline.net RESIDENTIAL GUNITE SPA PLAN r ..a 8 NOTES: 1. UNSUITABLE MATERIAL SHALL BE REMOVED UNDER LEACHING POOL UNTIL 6' MINIMUM PENETRATION INTO VIRGIN STRATA SAND AND GRAVEL AND BACKFILLED WITH SAND AND GRAVEL TO BOTTOM OF BASIN. CAST IRON FRAME & COVER IF UNDER PAVED AREA FINISHED GRADE 2. AS AN ALTERNATIVE TO THE DOME TOP, A FLAT SLAB CAN BE SUBSTITUTED WITH ��••�� � APPROVAL OF THE ENGINEER. 8' MIN. - 12' MAX. P%XT 24' t;���ti BRICK LEVELING COURSE I�MINyP-4 3. LOCATION OF DRAINAGE POOL TO BE DETERMINED BY OTHERS. CONCRETE COVER • PRECAST CONC. COLLAR MAX 4. ALL DRAINAGE PIPES MUST BE PROVIDED WITH A MINIMUM 2'-0" COVER. AS REQUIRED 5. COLLAR IS NOT REQUIRED WHEN RATEABLE MATERIAL EXISTS FOR FULL DEPTH. PRECAST REINF. CONC. 6. THE MATERIAL USED FOR COLLARING SHALL BE COMPRISED OF SAND AND DOME GRAVEL CONTAINING LESS THAN FIFTEEN (15) PERCENT FINE SAND, SILT AND CLAY. 4'0 PVC SILT AND CLAY FRACTIONS ARE NOT TO EXCEED (5) PERCENT. MIN. S PER FOOT ® ® ®Ell] INVER N ® ®®p NON-SHRINK � DRYWELL CALCULATION GROUT ®p REQUIRED: 3' MIN. SAND BACKWASH AT 70 GPM X 5 p AND GRAVEL J MIN. = 350 GAL. a - COLLAR (TYP) o a ALL AROUND W a PROVIDED: DRYWELL CAPACITY W PRECAST REINF. = 1,263 GAL. (169 CF) > CONC. LEACHING J U RINGS y L&i f W w W a 8' DIAMETER Ma �> �d W CL W v V zz cz z 6' MIN, PENETRATION iu o INTO VIRGIN STRATA CE GROUND WATER OF SAND & GRAVEL DRAINAGE POOL DETAIL NOT TO SCALE PREPARED FOR: LIVANOS 1795 CENTRAL DRIVE MATTITUCK, N.Y. 11952 A N DATE: 05/19/2017 NOTE: n HM ENGINEERING, P.C. SCALE: AS SHOWN THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF HM ENGINEERING P.C..UNAUTHORIZED �/ ALTERATIONS OR ADDITIONS TO THESE DOCUMENTS ARE A VIOLATION OF SECTION 7209 OF THE NEW YORK STATE / 3 CHERRYWOOD DRIVE EAST NORTHPORT,NY 11731 SHEET: 3 OF 3 EDUCATION LAW.INFRINGEMENTS WILL BE PROSECUTED. Tel:(516)476-5392 Fax:(631)980-7671 www.hmarnika@optonline.net DRYWELL DETAIL Ar: y 9 � wp, .MMA KMM WWOS 111�NM�WfNtf.�Y IYITIM t_ LYI• n ��L �. v\ o 1 w i �T .46 4, r R 6 � � o , T 1 �771ff a JUN 1 8 2026 uilding Depnrt"nt w f Sou old r � ._fir.. .� �P'� .....� � .. — - ,.+"�.s►??'".' .:tits ry �,r