Loading...
HomeMy WebLinkAbout50679-Z �oy�aof SO lyo�o Town of Southold * P.O. Box 1179 o 53095 Main Rd 00UNTN1 Y Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 47245 Date: 07/27/2026 THIS CERTIFIES that the building SINGLE FAMILY DWELLING Location of Property: 515 Sterling St Fishers Island,NY 06390 Sec/Block/Lot: 10.-9-3.1 Conforms substantially to the Application for Building Permit heretofore, filed in this office dated: 03/15/2022 Pursuant to which Building Permit No. 50679 and dated: 05/15/2024 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Single family dwelling with finished storage in basement,screened porch, decks, covered porch and attached garage as applied for. The certificate is issued to: J Geddes Parsons Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: R-21-1737 7/8/2025 ELECTRICAL CERTIFICATE: 50679 04/20/2026 PLUMBERS CERTIFICATION: Glenn Gello 04/22/2025 IV Authorized Signature �~ TOWN OF SOUTHOLD �o�g11FED`,�co, y BUILDING DEPARTMENT TOWN CLERK'S OFFICE o g SOUTHOLD NY sit BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 50679 Date: 5/16/2024 Permission is hereby granted to: Parsons, J Geddes 4 Palm Trl Hobe Sound, FL 33455 To: demolish an existing dwelling and construct a new single-family dwelling as applied for per DEC Non-Jurisdiction letter, Trustees & SCHD approvals. replaces by#47742 At premises located at: Sterling St, Fishers Island SCTM # 473889 Sec/Block/Lot# 10.-9-3.1 Pursuant to application dated 3/15/2022 and approved by the Building Inspector. To expire on 11/14/2025. Fees: PERMIT RENEWAL $2,170.25 Total: $2,170.25 Building Inspector �o�suf aiK o TOWN OF SOUTHOLD �y BUILDING DEPARTMENT TOWN CLERK'S OFFICE o SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 47742 Date: 4/27/2022 Permission is hereby granted to: Parsons, J Geddes C/O Parsons Capital Management 10 Weybosset St Ste 1000 Providence, RI 02903 l To: demolish an existing dwelling and construct a new single-family dwelling as applied for per DEC Non-Jurisdiction letter, Trustees & SCHD approvals. At premises located at: Sterling St., Fishers Island SCTM #473889 Sec/Block/Lot# 10:-9-3.1 Pursuant to application dated 3/15/2022 and approved by the Building Inspector. To expire on 10/27/2023. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $3,617.60 CO-NEW DWELLING $50.00 DEMOLITION $672.90 Total: $4,340.50 Bui ng Inspector FIELD INSPECTION REPORTFOUNDATION (1ST) MT MAP PI VIM AN VNI, •UGH FlIG PLUMBING :: AA �! STATE ENERGY CODE 1i\ _✓���/:�i/ice%��j �� � / ! In ADDITIONAL . • •• .. o �. ,-�a�I � WEST HARBOR 1 ELIZABETH PflBNOFF Rti rL�6oVlW N/F SINGLE FAMILY RESIDENCE ,A c,P �Q'G+� wra CHARLES W.GREEN(EAF T MUNICIPAL WATER Twrt SFpT®1 SITE 'VA CAM LAND' 1 ON STE SEPTIC SYSTEM x 5 •.` \ \ .-. ZL '\ '� / PREB-.NR _ �• \ J.GEDDES PARSONS _� war OtPJ STERUNG STREET nS FlSHERS ISLAND,NY o� \ LOCATION MAP SCALE 1'=400' \\ •trAoao rauiDm�tm K LLC :��� xaRP,P�ls°Paxtt Lisa aav"�°,oa""°o i wm P.uax asoza use NONTAU ��iNw ! 2)92 Pt�¢Pisv W.LSaW[s pAvsu�s ns•srtaxc sixsil SINGLE FAMILY .xr,sc c'-sC:o,s[:ro-a¢-ion dr atwrst RESIDENCE \ ASSCo,Ri MUNICIPAL WATER ON SITE SEPTIC SYSTEM \\J_ / ra 0� tlGIEY ��� +fAp j \\\ // uimLcvi �P�man at vx sixes uIrmMs IR rEimxet'r ai �n N/F )n s, u eusno � counacp NONAS J. LLO ro 4P¢�NEW FD �a SINGLE F-.Y RESIDENCE 1gaLr u�1nNrsN4neir x,mcm taix sxc vim nmetmxs 'tg^osta MUNICIPAL WATER D®os4n oA wx U•wE ixE M"M ru IAND`+ slla&L!ID IWIe A9lSs��111TL /./ \ ON SITE SEPTIC SYSTEM M LAd suaaMrn. 9p_� µo cE... // m \ E&� Lvt,na ¢ sEci9p�xµ0t0.BLMEcptT.eCAO 0.stvMwD,m,xty oT Rlnn[,..x,a tmo �,:-r^���-m. 9 5 —to I5� • rrzse tpro1�PARCEI ACQUIRED BY I / J.GEDDES PARSONS 1 LIBER DOOOI.i1J1 PACE 657 t I / ♦ its R 11-29-2021 pSs .EWES JEANNIE ENT I m SINGLE FAMILY RESIDESD CENCEUN xuL ---- -,y------- MICIPAL WATER ON SITE SEPTIC STSiFY gg _ ~� I Y NI rea C / I muxom wart o I" mY WM�xEO z� N 131669 N T0r99 IT TIES FOR SEPTIC SYSTEM TO POINT FROM POINT'A' FROM POINT'B' DESCRIPTION Su 0J o I I I SU17FC:K COUNTY DEPARTMENT O`HEA•TM..SER�!CES 4' t I APPROVAL OF CONSTRUCTED WORKS FOR s°fwrs-• % e�+° SA SINGLE FAtA:LN'RES!DENCE AS-BUILT PLAN / I Dale_ n S ReL!:0 R-21-17n aav I N/F 1 ^szura-__ _-___ SMRGIOf ETA C.ELWELL FAMILY RESDENCE / - ,^.2 ESp:sa1 siC',sz, 'vzp+!aclAC lv ga.".xa.¢E2CD acn I MUNICIPAL WATER / / u�^d^qM d:dbr cz'r c'�t+s OC.^art'wnr,r C:r:2r eC.-C cs a -r-tl Prgx� ON SIZE SEPT, YSiEY C S sa!rs!aJoty FORAL•v VCF s BEPROC..:S. o� SHEET 1 01'.di v,as;:»ace;rAanayemnl " TOWN OF SOUTHOLD �s�fFntK� , aye BUILDING DEPARTMENT y TOWN CLERK'S OFFICE "oy SOUTHOLD, NY col BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 47742 Date: 4/27/2022 Permission is hereby granted to: Parsons, J Geddes C/O Parsons Capital Management 10 Weybosset St Ste 1000 Providence, RI 02903 To: demolish an existing dwelling and construct a new single-family dwelling as applied for per DEC Non-Jurisdiction letter, Trustees & SCHD approvals. At premises located at: Sterling St., Fishers Island SCTM # 473889 Sec/Block/Lot# 10.-9-3.1 Pursuant to application dated 3/15/2022 and approved by the Building Inspector. . To expire on 10/2712023. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $3,617.60 CO-NEW DWELLING $50.00 DEMOLITION $672.90 Total: $4,340.50 Bu ing Inspector r Town Hall Annex �� Gym Telephone(631) 765-1802 54375 Main Road .� P. O. Box 1179 Z Southold, NY 11971-0959 Oy �.i BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATION Date: Y/z z/,->0 Z Building Permit No. V021 Owner: (Please print) II IDPlumber: 66VI eI (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1%lead. (Plumbers Signature) Sworn to before me this Z2 d� day of P , 20 Z5' Notary Public, <54 r-AP.L4L County 1 hod&pF SO(/lyOlo Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 Southold,New York 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: J.Geddes Parsons Address: 515 Sterling St city: Fishers Island st: NY zip: 06390 Building Permit#: 50679 Section: 10 Block: 9 Lot: 3.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Electrician: Z&S Electric License No: 4798ME SITE DETAILS Office Use Only Commercial Indoor X Basement X Service X Solar Residential X Outdoor X 1st Floor X Pool Battery Storage As-,built Renovation 2nd Floor X Hot Tub EV Charger New X Addition Attic X Spa Generator Survey Mezzanine Garage Dock INVENTORY Service 1 ph 300A In-wall Heater Recpt 135 Ceiling Fixtures 105 Smoke Detectors Pump Service 3 ph Hot Water Gas GFCI Recpt 28 Wall Fixtures CO Detectors Heater Main Panel 150 A/C Condenser 4 Single Recpt RecessdFixtures 22 Combo Smoke/CO 25 Transformer Main Panel 150 A/C Blower 4 Range Recpt 50A Ceiling Fan 6 Heat Detectors 1 Ice Maker 1 Transfer Switch 150X2 Mini Split Dryer Recpt 30X2 UC Lights 15 Fridge 2 Cooktop 1 ARC Blower Heads Switches 108 Pucks Lights Dishwasher 2 Mini Fridge 2 GFI Floor Heat 5 mrgency Strobe 4'LED Microwave 2 Garbage Disp. 2 ARC/GFI 24 ERV 2 Exit Lights Bath Exhaust 5 Hood 2 Dehumidifier 2 Other Equipment: 50A Car Charger Notes: New Two Story w/ Finished Storage Only Basement Inspector Signature: Date: April 20, 2026 Glenn Goldsmith, President �OF 50!/r� Town Hall Annex Nicholas Krupski,Vice President �OVv ®�® 54375 Route 25 P.O. Box 1179 Eric Sepenoski Southold, New York 11971 Liz Gillooly G Telephone(631) 765-1892 Joseph Finora �� • y® Fax(631) 765-6641 BOARD OF TOWN TRUSTEES JUL 2 7 2026 TOWN OF SOUTHOLD Building Department CERTIFICATE OF COMPLIANCE TOWn Of Southold #2362 C Date: July 27, 2026 THIS CERTIFIES that the demolition of existing single-family dwelling_pumping out of the existing_sanitary system and removal of all material from site; construction of a single-family dwelling with attached garage three(3)drywells for roof runoff, decks and steps for a footprint of 4 306sq ft installation of new water service; installation of an I/A OWTS sanitary system and regrading; repair of existing 132' seawall; construction of a 132' block retaining wall landward of existing seawall; backfilling the structure with approximately 95 cubic yards of clean fill to match existing elevation;reconstruction of a 48' long bulkhead return located at the western side of the property and construction of a 4.9'-6' x 48.3' (varying width)concrete walk located immediately landward of reconstructed return; installation of an 8' x 6' dawell• mulching and seeding of the 2 630sq ft disturbed area; establishment of a non-turf buffer between bulkhead and retaining wall and installation of a 10'wide non turf buffer landward of the retaining wall, At 515 Sterling Street, Fishers Island Suffolk County Tax Map#1000-10-9-3.1 Conforms to the application for a Trustees Permit heretofore filed in this office Dated August 23,2021 pursuant to which Trustees Wetland Permit#10005 Dated October 20, 2021,was issued and conforms to all of the requirements and conditions of the applicable provisions of law. The project for which this certificate is being issued is for the demolition of existing single-family dwelling-, pumping out of the existing_sanita!y system and removal of all material from site; construction of a single-family dwelling with attached garage three(3)drywells for roof runoff, decks and steps for a footprint of 4 306sq_ft• installation of new water service; installation of an I/A OWTS sanitary system and regrading;repair of existing 132' seawall; construction of a 132' block retaining wall landward of existing seawall; backfilling the structure with approximately 95 cubic yards of clean fill to match existing elevation; reconstruction of a 48' low bulkhead return located at the western side of the property and construction of a 4 9'-6' x 48 3' (varying)concrete walk located immediately landward of reconstructed return; installation of an 8' x 6' drywell• mulching and seeding of the 2 630sq.ft. disturbed area; establishment of a non-turf buffer between bulkhead and retaining wall and installation of a 10' wide non turf buffer landward of the retaining wall. The certificate is issued to J. GEDDES PARSONS owners of the aforesaid property. Authorized Signature 3/28/25, 10:31 AM W% r, S+W ai ar it w' / ra�lg Gm ail Z&S Contracting, Inc. <zandscontracting@gmail.com> Parsons - Permit #47742 windows w/storm guard rating 1 message Z&S Contracting,inc. <zandscontracting@gmail.com> Fri, Mar 28, 2025 at 10:31 AM To: "Verity, Mike" <Mike.Verity@town.southold.ny.us> Mike, Hi, please see attached is a typical window for the Parsons house showing that they were ordered with storm guard rating., Thanks, Paul Parsons Permit#47742 window showing w-storm guard rating.pdf 32K https://mail.google.com/mail/u/0/?ik=29cd8fe8bO&view=pt&search=all&permthid=thread-a:r-5467335340950318691%7Cmsg-a:r-64918753862660441... 1/1 OMS Ver.0003.15.00(Ccr * �0� r SrJI`S ZSC-Parsons(5ta dard Coior) Product availability and "i n "'le to change. VVV riiag5 ®r5 island Nv quote Number $1.ZY6Z5 l LINE I7EI� The fo' ned''le:of the windows and doarsfor this project. For additional unit:details, please see Line Item Quo r gat_,arges,tax or-Terns and;Cartd t€ons may apply. Detail pricing is per unit. ark Unit:A 6-9/16 .primed} Net Price: 3,093.88 Ext.Net Price: USD 12,375.52 Winebe'er C�= xtersor U#tuna?tg zc E uscg G2 — -- --� ( Cfx3e3 8-$ s or uuots Low E2 w/Argon d S aco pacer Bar 7f8'SDL UVkh Spacer Bar Black e .. or- Special Cut 3W3H g UVlnetierry Glad Exi-Primed Pine inf x Ogee interior Glazing Profile Bottom Sash Wineberry Clad Sash Exterior AsViToied From The Extedor Primed Pine Sash Interior tt3 3632 IG-1 Lite RCi 42 Y/4"X 72" StormPlus.Low E2 w/Argon Black Perimeter Bar Ogee Interior Glazing Profile White Interior Weather Strip Package Black Exterior Weather Strip Package Oil Rubbed Bronze Sash Lock Oil Rubbed Bronze Top Sash Strike Plate Assembly Color Extruded Aluminum Half Screen Wineberry Surround Bright View Mesh 6 9/16"lambs AL Nailing Fin **'Note;:Reference the installation instructions for StormPlus certification requirements- '*°Note: Unit Availability and Price is Subject to Change OMS Ver.0003,15.00(Current) Processed on 7/28/202211:39:29 AM Page 4 of 27 is=. AZT Albert -Righter-Tittmann ARCHITECTS Date: 25 Match 2025 MAR 2 5 2025 To Mike Verity Building Department of Town of Southold NY From: Jacob Albert A,R&T Architects,Inc. Re: Kathryn&Geddes Parsons house 515 Sterling St. Fishers Island NY 06390 Suffolk Co.Tax Map 1000-10-9-3.1 Enclosed: Photographs This is to let you know that I observed the closed-cell spray-foam insulation (R-7 per inch)in exterior 2x12 roof rafter bays and V floor rim joists and received photographs from Z&S Contracting of the closed-cell foam insulation in the exterior 2x6 stud wall cavities. Closed-cell spray-foam roof insulation has been covered with intumescent paint in accessible unfinished attic areas. The Superior Walls foundation came with interior rigid insulation (R-12),to which Z&S added rock-wool batts to fill the cavities. The insulation appeared to be consistent with design and details drawn by us,and is,to the best of my knowledge,in accordance with applicable New York State codes. Photos of insulation are enclosed. Very truly yours, !p N��- 0 0 A 4 "Q, 10 Jacob D. Albert hir AC A,R&T Architects, Inc. 33 Ujaibn-Street 4th Floor Boston, NIA 02108 617.451-5740 APTarchitects.com oMS Ver.0003.15.00(Cur:enz 7SC Parsons(Sa rd Calor) NY Product awailability and 's iutiject to change. U ��� Quote Number 8lZY6Z6 _ . LINE ITEM QUOTES The foilcw0g t.a.sciedule of the windows and doors for this project.For additional unit'detaiis,please see Line Item Quotes.. Add tionat-charges,tax or Terms and Conditions may apply. Detail pricing is per unit. Line$1 mark-Unit:A(6-9/16"primed) Net Price: 3,093.88 (1ty: Ext.Net Price: USD 12,375.52 Wineberry Ciaa Exterior MAI(1';�1/iN ' Primed fKine*fie'or ultimate DOU6e ii sng G2 CN 3634' i Ro r$h Cpr-".q 42 I'S'X 72' We•�� c%,4 srsh Exterior Ir in:, ��/r F ?2rretS a se Sash Interior �r v Storm lt*low E2 w/Argon J r: aver Bar 7/r SDL-With Sparer Bar-Black MAR 2 8 2025 L Rectangular-Special Cut 3W3H Wineberry Clad Ext-Primed Pine int Ogee Interior Glazing Profile i Bottom Sash ` Wineberry Clad Sash Exterior As Viewed From The Exterior Primed Pine Sash interior 3fi 32 IG-i Ute W RO 36 2 X 72' StormPlus Low E2 w/Argon Black Perimeter Bar Ogee Interior Glazing Profile White Interior Weather Strip Package Black Exterior Weather Strip Package oil Rubbed Bronze Sash lock Oil Rubbed Bronze Top Sash Strike Plate Assembly Color i Extruded Aluminum Half Screen Wineberry Surround Bright View Mesh b 9/16"lambs AL Nailing Fin ***Note:Reference the installation Instructions for StormPlus certification requirements. ` •••Note: Unit Availability and Price Is Subject to Change OM5 Ver.0003.15.00(Current) Processed on:7/29/202211.39:29 AM Page 4 of 27 pF 50UTyo / # # TOWN OF SOUTHOLD BUILDING DEPT. cou 631.765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2 ] INSULATION/CAULKING [�RAMING /STRA PING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: ®A -�- � DATE Uri 171.2-> INSPECTOR2�t���- 0�0/ � �apF SOUThO�o ` # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2N ] INSULATION/CAULKING [ FRAMING /STRAP I N Gj ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: ` a8 DATE INSPECTOR SO(/TyO TOWN OF SOUTHOLD BUILDING DEPT. CO ,N 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I ULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL [ :] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION. [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: IN- -A,: DATE 07/-,W/.:2-s---jNSPECT0R pF SOUTyolo * TOWN OF 'SOUTHOLD BUILDING DEPT. `ycoulm, 631 765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ .°] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ . -] 'FIREPLACE & CHIMNEY , [ ] FIRE SAFETY INSPECTION -[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE-RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ]- PRE C/O [ ] RENTAL RE ARKS: U UY � nAra a, a . op qnjdla c' d/ C � 1 p r LN) Jt)n 4c r /'A 11QA.A_ DATE 12_ _�INSPECTOR 0 1V ] SIEGEL I STRUCTURAL ENGINEERS M AY - 7 2025 May 2, 2025 Michael J.Verity Southold Building Department Town Hall Annex Building,54375 Route 25 P.O. Box 1179,Southold, NY 11971 Re: Final Structural Affidavit Parsons Residence, Building Permit#47742 Sterling Street, Fishers Island, NY Dear Michael, Siegel Structural Engineers has been retained by ART Architects to perform as the Structural Engineer of Record for the above-referenced project. In this capacity we reviewed architectural plans, performed structural calculations, and produced structural plans,sections, and notes that were previously submitted for Permit. In addition, we visited the project site periodically during construction to confirm compliance with our design, including framing members, strapping, holddowns, shear walls, and the Superior Wall precast concrete foundation system. To the best of my knowledge,information and belief,based on limited observation,the structural work generally complies with our design,with the structural provisions of the New York State Building Code for One-and Two-Family Dwellings,and with accepted structural practice. Please feel free to contact me with any structural questions about this project. Very truly yours, SIEGEL STRUCTURAL ENGINEERS �O AtJ� Steven P. Siegel, P.E., Principal 617.244.1612 www.slegelstructural.com 860 Walnut Street,Newton Centre,MA 02459 Glenn Goldsmith, President ,r SQUT Town Hall Annex Nicholas Krupski,Vice President �Ow �� 54375 Route 25 P.O. Box. 1179 Eric Sepenoski J ,1 Southold,New York 11971, Liz Gillooly N Joseph rinora �O • � Telephone(631) 765.1.892 Fax(631) 765-6641. C4UNTI,�` BOARD OF TOWN TRUSTEES TOWN OF soUTHOLD March 20, 2026 JMO Environmental Consulting _.� PO Box 447 Quogue, NY 11959 r_� �� A,PR 1 5 2026 RE: J. GEDDES PARSONS ??r•�BU�i� t� �44 � 515 STERLING STREET, FISHERS ISLAND w SCTM#: 1000-10-9-3.1 Dear Mr. Just: The following action was taken by the Southold Town Board of Trustees at their Regular Meeting held on Wednesday, March 18, 2026: RESOLVED, that the Southold Town Board of Trustees APPROVE the Administrative Amendment to Wetland Permit#10005 and Coastal Erosion Permit#10005C for the as- built reconstruction of a 48' long bulkhead return located at the western side of the property and as-built construction of 4.9'-6' x 48.3' (varying width) concrete walk located immediately landward of reconstructed return; install an 8' x 6' drywell; saw cut and remove two portions of existing concrete walk and install two French drains to be connected to drywell; and to install a 10' wide vegetated non-turf buffer along the landward side of the retaining wall. Any other activity within 100' of the wetland boundary requires a permit from this office. This is not a determination from any other agency. If you have any questions, please call our office at (631) 765-1892. Sincerely, a Glenn Goldsmith, President Board of Trustees ....... .... ..... .... . . ......... .................................. ........... BOARD OF SOUTHOLD TOWN TRUSTEES SOUTHOLD, NEW YORK PERMIT NO. 10005&10005C DATE: OCTOBER 20,2021 ISSUED TO: J. GEDDES PARSONS PROPERTY ADDRESS: 515 STERLING STREET,FISHERS ISLAND SCTM# 1000-10-9-3.1 AUTHORIZATION Pursuant to the provisions of Chapter )75 and,orChapter 11 I of the Town Code of the Town of Southold and in accordance with the Resolution of the Board of Trustees adopted at the meeting held on October 20.2021 and in considera tion of application fee in the sum of$500.00 paid by J. Geddes Parsons and subject to the Terms and Conditions as stated in the Resolution,the Southold Town Board of Trustees authori zes and pen-nits the following: Wetland Permit to demolish existing single-family dwelling; pump out the existing sanitary system and 0. remove all material from site; construct a new single-family dwelling with attached garage,three(3) drywells for roof runoff, decks and steps for a footprint of 4,306sq.ft.; install new water service; install a new I/A OWTS sanitary system and regrade; to repair the existing 132'seawall;to construct a new 132' block retaining wall landward of existing seawall; to backfill the structure with approximately 95 cubic yards of clean fill to match existing elevation;and to mulch and seed the 2,630sq.ft.disturbed area; establish and perpetually maintain a non-turf buffer between bulkhead and retaining wall and install and perpetually maintain a 10'wide non turf buffer landward of the retaining wall;and as depicted on the site plan prepared by CME Associates Engineering, Land Surveying &Architecture, PLLC, received on October 19,2021,and stamped approved on October 20,2021. IN WITNESS WHEREOF', the said Board of Trustees hereby causes its Corporate Seal to be affixed and these presents to be subscribed by a majority of the said Board as of the 20th day of October,2021. ,_�v4%4f F01 1, � � _ `� {i�.. / 14 co coo • Glenn Goldsmith,President �ra�zsoo: Town Hall Annex A-Nicholas Krupski,Vice President ,�O ��� 54375 Route 25 P.O. Box 11.79 John M. Bxedemeyer III Southold,New York 11971 Michael J.Domino Telephone(631) 765-1892 Greg Williams Fax(631.) 765-6641 Cou BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD COASTAL EROSION MANAGEMENT PERMIT COASTAL EROSION PERMIT #10005C Applicant/Agent: J.M.O. Environmental Consulting Permittee: J. Geddes Parsons SCTM#: 1000-10-9-3.1 Project Location: 515 Sterling Street, Fishers Island Date of Resolution/Issuance: October 20, 2021 Date of Expiration: October 20, 2023 Reviewed by: Board of Trustees DESCRIPTION OF ACTIVITY: Demolish existing single-family dwelling; pump out the existing sanitary system and remove all material from site; construct a new single-family dwelling with attached garage, three (3) drywells for roof runoff, decks and steps for a footprint of 4,306sq.ft.; install new water service; install a new UA OWTS sanitary system and regrade; to repair the existing 132' seawall; to construct a new 132' block retaining wall landward of existing seawall; to backfill the structure with approximately 95 cubic yards of clean fill to match existing elevation; and to mulch and seed the 2,630sq.ft. disturbed area; establish and perpetually maintain a non-turf buffer between bulkhead and retaining wall and install and perpetually maintain a 10'wide non turf buffer landward of the retaining wall; and as depicted on the site plan prepared by CME Associates Engineering, Land Surveying & Architecture, PLLC, received on October 19, 2021, and stamped approved on October 20, 2021. INSPECTIONS: Final Inspection SPECIAL CONDITIONS: None In accordance with Chapter 111-15 Erosion Protection Structures: xx A maintenance agreement is attached hereto and is a necessary special condition of this permit. 4, ; /By: ,or Glenn Goldsmith, President Board of Trustees • Glenn Goldsmith,President ��®F SDUjyo Town Hall Annex A. Nicholas Krupski,Vice President l4 i~ 54375 Route 25 P.O. Box 1.1 79 John M.J3redeme}*er III Southold, New York 11971 Michael J. Domino G Telephone(631) 765-1892 Greg Williams 'rQ y0 Fax(631) 765-6641. IyCQUNri,� N BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD October 21, 2021 Glenn E. Just J.M.O. Environmental Consulting Services P.O. Box 447 Quogue, NY 11959-0447 RE: J. GEDDES PARSONS 515 STERLING STREET, FISHERS ISLAND SCTM#1000-10-9-3.1 Dear Mr. Just: The following action was taken by the Southold Town Board of Trustees at their Regular Meeting held on Wednesday, October 20, 2021: WHEREAS, J.M.O. Environmental Consulting, on behalf of J. GEDDES PARSONS applied to the Southold Town Trustees for a Permit under the provisions of Chapter 275 of the Southold Town Code, the Wetland Ordinance of the Town of Southold, and Chapter 111 of the Southold Town Code, Coastal Erosion Hazard Areas, application dated August 23, 2021, and, WHEREAS, said application was referred to the Southold Town Conservation Advisory Council and to the Local 'Waterfront Revitalization Program Coordinator for their findings and recommendations, and, WHEREAS, the LWRP Coordinator issued a recommendation that the seawall work is recommended as Consistent with the Local Waterfront Revitalization Program policy standards, and WHEREAS, the LWRP Coordinator recommended that the action be found Inconsistent with the LWRP, and, WHEREAS, the Board of Trustees has furthered policy of the Local Waterfront Revitalization Program to the greatest extent possible through the imposition of the following Best Management Practice requirements: upon Trustee review - the plan and project description submitted satisfy the concerns of the LWRP; and 2 WHEREAS, a Public Hearing was held by the Town Trustees with respect to said application on October 20, 2021, at which time all interested persons were given an opportunity to be heard, and, WHEREAS, the structure complies with the standards set forth in Chapter 275 and Chapter 111 of the Southold Town Code, WHEREAS, the Board has determined that the project as proposed will not affect the health, safety and general welfare of the people of the town, NOW THEREFORE BE IT, RESOLVED, that for the mitigating factors and based upon the Best Management Practice requirement imposed above, the Board of Trustees deems the action to be Consistent with the Local Waterfront Revitalization Program pursuant to Chapter 268 of the Southold Town Code, and, RESOLVED, that the Board of Trustees APPROVES the application of J. GEDDES PARSONS to demolish existing single-family dwelling; pump out the existing sanitary system and remove all material from site; construct a new single-family dwelling with attached garage, three (3) drywells for roof runoff, decks and steps for a footprint of 4,306sq.ft.; install new water service; install a new I/A OWTS sanitary system and regrade; to repair the existing 132' seawall; to construct a new 132' block retaining wall landward of existing seawall; to backfill the structure with approximately 95 cubic yards of clean fill to match existing elevation; and to mulch and seed the 2,630sq.ft. disturbed area; establish and perpetually maintain a non-turf buffer between bulkhead and retaining wall and install and perpetually maintain a 10' wide non turf buffer landward of the retaining wall; and as depicted on the site plan prepared by CME Associates Engineering, Land Surveying & Architecture, PLLC, received on October 19, 2021, and stamped approved on October 20, 2021. Permit to construct and complete project will expire two years from the date the permit is signed. Fees must be paid, if applicable, and permit issued within six months of the date of this notification. Inspections are required at a fee of$50.00 per inspection. (See attached schedule.) Fees: $ 50.00 Very truly yours, m ,m Glenn Goldsmith President, Board of Trustees _ � P AE; r s �\ f I Y 5 ;� 1� JJ k 11 I IrI 1 r ! JMO Environmental Consulting 26 Topping Drive Riverhead,NY 11901 631-653-0607 July 27, 2026 Mr. Michael J. Verity, Chief Building Inspector Q Building Department De 6 � p26 Town of Southold 21 2 Town Hall Annex 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Re: Parsons, 515 Sterling Street, Fishers Island S.C.T.M. No. 1000-10-9-3.1 Re: Declaration of Covenants Dear Mr. Verity- Enclosed please find are the Declaration of Covenants which have been files with the office of the Suffolk County Clerk. Res e lly- lenn E. Just CC#: C26-42717 COUNTY CLERK'S OFFICE STATE OF NEW YORK COUNTY OF SUFFOLK I, Clerk of the County of Suffolk and the Court of Record thereof do hereby certify that I have compared the annexed with the original DECLARATION recorded in my office on07/27/2026 under Liber D00013344 and Page393 and, that the same is a true copy thereof, and of the whole of such original. In Testimony Whereof, I have hereunto set my hand and affixed the seal of said County and Court this 07/27/2026 SUFFOLK COUNTY CLERK VINCENT PULEO SEAL IIIIIII IIII IIIII IIII i IIIII IIIII IIIII IIIII 1111 IN I(IIIII 11111111111111 III SUFFOLK COUNTY CLERK RECORDS OFFICE RECORDING PAGE Type of Instrument: DECLARATION Number of Pages: 11 Recorded: 07/27/2026 Receipt Number : 26-0090720 At: 11 :45 :40 AM LIBER: D00013344 District: Section: Block: PAGE: 1000 Lot: 393 010.00 09. 00 003. 001 EXAMINED AND CHARGED AS FOLLOWS Received the Following Fees For Above Instrument Exempt Exempt Page/Filing $55.00 NO Handling $20 , 00 NO COE $5.00 NO NYS SRCHG TP-584 $0 .00 NO Notation $15.00 NO Cert.Copies $13. 75 NO RPT 0.00 NO $200.00 ;NO Fees Paid $308 .75 THIS PAGE IS A PART OF THE INSTRUMENT THIS IS NOT A BILL VINCENT PULEO County Clerk, Suffolk County DECLARATION OF COVENANTS • THIS DECLARATION made this 3&!4 -day of � Parsons, residing at 4 Palm Trail, Hob 20'�� by J. Geddes e Sound FL 33455, hereinafter referred to as • "DECLARANT(S) W I T N E S S E T g ; WHEREAS, DECLARANT(S) is/are the owner(s) of certain real property located on 515 Sterling Street, Fishers Island, Tow n of Southold, County of Suffolk, State of New York, described in the Suffolk County Tax Ma Section 010.00 Block 09.00 Lot 003.001 which is more P as District 1000, described as set forth in Schedule °A" an particularly bounded and annexed hereto, hereinafter referred to as the Property; WHEREAS, the property is situated on lands within the Board of Trustees of the Town of Southold jurisdiction of the to Chapter 275 of the Town (hereinafter the "Trustees") pursuant Code of the Town of Southold or its successor, various activities conducted upon the and Property may thus be subject to the regulation and approval of the Trustees prior to being conducted;WHEREAS, the DECLARANT(S)( ) therefore made application to the Trustees for a Permit pursuant to the Wetlands Law of the Town of Southold to and regulated activities.• and ertake certain WHEREAS, as a condition of the granting of a Wetlands Permit to undertake such regulated activities, the Trustees required that to establish maintain a non-turf buffer between bulkhead and retaining wall and and perpetually perpetually maintain a 10' wide non-turf buffer landward of the a retaining and and as depicted upon the site tan fining wall; P p P prepared by CME Associates En ineerin Surveying & Architecture, PLLC received on October 19 g g' Land on October 20 2021 and ' 2021, and stamped approved amended on March 18, 2026 WHEREAS, the DECLARANT has considered the foregoing the same will be for the best interests of the DECLARANT andd has determined that the Property. subsequent owners of NOW, THEREFORE, the DECLARANT(S) do/does hereby covenant and agree as follows: 1) Upon the ( substantial completion of the aforementioned activities there shall be established and Permitted Perpetually maintained a non- turf buffer -.bulkhead and retainin wall and install and Perpetually maintain a l0' wide non-turf buffer .landward of the retainingwall — non-turf buffer" as defined by Chapter 275 of the Town Code, to wit: "A designated area where turf grass, pesticides and fertilizers are not Permitted." and as depicted on the site Plan prepared by CME Associates Engineerin Land Surveying & e Architecture PLLC received 202 n October 19, a roved on October 20 2021 and 2026. amended on March 18, see Exhibit "A" attached; and ✓ 2) These covenants shall run with the land and shall be binding on the DECLARANT(S) , his/her/their heirs, assigns, purchasers, or successors in interest and may only be modified after a public hearing and upon resolution of the Trustees. IN WITNESS WHEREOF, the owner(s) has/have duly executed this instrument this day of T Z4J 207 4: I Pa 3NAT�c)" j OWNER'S SIGNATURE STATE OF NEW YORK ) COUNTY OF �/ �f ss: On the A�_ day of V year 20 der , in the 0? , before me the gned, a Notary Public in and for said State, personal) a�� h✓ , personally known to me or roved y appeared satisfactory evidence to be the individual (s) whose name (s)oi.s/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their capacity, and that by his/her/their signature(s) on the instrument, 2 the individual or the persons on behalf of which the individual ($) acted the instrument, the Notary is JASON KDRENA .,,Ity Qualified in Suffolk County 1. (�� No.0IDR6350454 Notary Public-State of New York �•''•,•.,,,,�YY tb Couvaisslon Expires Nouemliee ITT,2M 4C� •' . ,� , 1 µ i f 3 Title NCI RHO7300199 SCHEDULE A - DESCRIPTION AMENDED 03/13/07 . County of Suffolk and State of New York, bounded and-described as follows: ALL that certain tract, piece or parcel of land, situated at Fishers Island, in the Town of Southold, BEGINNING at a stone monument on the Westerly line of Sterling Street, said monument being 1582.94 feet North of a point which is 172.66 feet West of another monument marking the U.S. Coast and Geodetic Survey Triangulation Station "PROS', and RUNNING THENCE North S8 degrees 12 minutes 00 seconds West;75.37 feet; , RUNNING THENCE South 17 degrees 04 minutes 00 seconds West, 31.50 feet; RUNNING THENCE South 57 degrees 26 minutes 00 seconds East,.75.00 feet to the westerly line of Sterling Street; THENCE along the westerly side of Sterling Street South 25 degrees 01 minute 15 seconds West, 78.84 feet; THENCE along the westerly side of Sterling Street South 25 degrees 01 minute 15 seconds West, 17.00 feet,to an Iron pipe; THENCE South 84 degrees 39 minutes 15 seconds West, 160.S6 feet to an Iron pipe; THENCE North 03 degrees 06 minutes 40 seconds West, 114.34 feet to an Iron pipe; THENCE North 77 degrees 14 minutes 51 seconds West, 168.98 feet to an Iron pin which Is North 44 degrees 22 minutes 00 seconds East, 74.36 feet from a monument on the southeasterly line of Montauk Avenue, said monument being 1548.63 feet North of a point which is 605.97 feet West of a monument marking the U.S. Coast and Geodetic Survey Triangulation Station'"PROS"; THENCE North 44 degrees 22 minutes 00 seconds East, 206.54 feet to a stone monument; THENCE North 67 degrees 34 minutes East, 3.34 feet to a stone monument; , THENCE North 81 degrees 06 minutes 30 seconds East, 64.80 feet to a monument; THENCE North 76 degrees 07 minutes 25 seconds East, 46.07 feet to a drill hole in a wall; THENCE North 69 degrees 34 minutes SO seconds East, 47.21 feet to a stone monument; THENCE North 49 degrees 50 minutes 10 seconds East, 55.80 feet to a drill hole in the face of a retaining wall at the shore of West Harbor; RUNNING THENCE along West Harbor the following two (2) tie line courses and distances: 1. South 51 degrees 22 minutes 54 seconds East, 95.87 feet; 2. South 65 degrees 41 minutes 00 seconds East, 35.00'feet; Cerufleate or We THENCE South 32 degrees 00 minutes 36 seconds West, 117.98 rest partly along the northwesterly line or sterling Street to a drill hole; THENCE along said street line South OS degrees 01 minutes 40 seconds West, 67.32 feet to the point or place of BEGINNING. pq / -e•J4� `���1��_ 3 a Uv" / 4k\ )�Jj� r: . , <��� � ,�, y ,� ,.4•z`� ����,, �_ „\�j \:/ K� �tr/.�,rrr, f •. < r�rrr rsrM' ,�tit�_ ��Jk k, { i l}!h r �, �tif{7 •' /yis" �} a�4. �`; � i ^t _ �''� r i rf 1 �. f\ /l-'# iL,3,.2•'�1r '! i. ;�T?'tti"� 'r~ K � t�bn ti)f"`3 P a d. 1} ^d. , �\ /j Y �, < yC�% 9 / ��t ,,✓yHti �//f(�r � r r .z��k..>L>F�� ��;1.� ,.�l�'�^1�.���f'.f�'.',rY �s��� rpF�.l'• •1.. �_.,�'F' ��' C..,.+.I��... f^ �f /.""�.�`*l-.-, •;� • ;e.-A � ,7 sTi /,31-�c /o A- tr �r� Rmli�.. r.,T.'c�i'rGoitc 1r a._ �S 3 �F% ��1 r ? �yy`Y� h y-.a,ar Tf].rTiUl�//F+1�711F1I j71• -(1T. �s:kt• J�,Tj///�1\\..J S 1 r � tl\�p/J — .�z{aTtj"�.'v7n'9G C✓jT_ l,� R C 7i�??lTi"^l"J�. F✓r l,`" x -Asln . � III tifif 4 v r t t �( 1 1 1 11' • z k ... '�,2 r�(r3 � •I- 1 1 :!• 11� 1' 11 1 11 1 � ��7--)—_� t zA: yt JI • _ (�`�`y�' •.• hLy . EMEMP /. e �\6'�{ICY • _ 1 _ r. .:• • . •, '. . • •.: 1 1 �� ':` ! u „f� —�r 1 {? r., L::Ji.\\� 1 nrl„ n �1 n r do tnvs •m _ y nn Z_ �.� x • ..� � J '�" 3'P".>r �3.t '� C�..y�.c;�yi (. �/ .;` ixf•5 �'S._�� y '"�?l arVi�' '# .�' hL r �,`_ �, rim _ ..Lp h •`f '' k'/ �`��� <r,:r•,., �� V 1Y. .` yy.Y �3;.� '�, tiP.f,r _,Jl �"�",r .r /f �yx•;>r� �`� ���, i m. ,:r'6Y. Y�t,.\�_ us wuur:u.ai' _ 1 • ._, �t. r�,r-f4tf�te��yrr V/! t It A , U tF '�4MKcilu..Lib r .1- �„y'SJt 14 7{,,�. `y i k,' r �g ,U I C• 1 "IS1W+t1�Suu;' f 3 iy.'i% WlN' V �.. q Glenn Goldsmith,President SQ(/ry Town Hall Annex Nicholas Krupski,Vice President. �0� ®�� 54376 Route 25 P.O.Box 1179 Liz Gi Eric S llool Fino ki Southold,New York 11971 er+ Telephone(631) 765-1892 Joseph inora !� w�yO Fax(631) 765-6641 Cowl BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD March 20, 2026 JMO Environmental Consulting PO Box 447 Quogue, NY 11959 RE: J. GEDDES PARSONS 515 STERLING STREET, FISHERS ISLAND SCTM#: 1000-10-9-3.1 Dear Mr. Just: The following action was taken by the Southold Town Board of Trustees at their Regular Meeting held on Wednesday, March 18, 2026: RESOLVED, that the Southold Town Board of Trustees APPROVE the Administrative Amendment to Wetland Permit#10005 and Coastal Erosion Permit#10005C for the as- built reconstruction of a 48' long bulkhead return located at the western side of the .property and as-built construction of 4.9'-6'x 48.3' (varying width) concrete walk located immediately landward of reconstructed-return; install an 8' x 6' drywell; saw cut and remove two portions of existing concrete walk and'install two French drains to be connected to drywall; and to install a 10' wide vegetated non turf buffer along the landward side of the retaining wall. Any other activity within 100' of the wetland boundary requires a permit from this office. This is not a determination from any other agency. If you have any questions, please call our office at(631) 765-1892. Sincerely, Glenn Goldsmith, President Board of Trustees / 7 L WEST V1�V►� MOOR rauats i vAav&AM l Dx atE svnc s�islEir min « @ .� :mE\_ L GEODES PARSMRS wsr�3 \ mra °k�r tDGiroN ww SME t-40T `mats swa xr .v000 m,um WW{{--UC ® xocc.nnE .mucnu.�ro.®lwxmne,�een= SN2E FALr \ dorm `4 � jro �m�e.�n a°ii�i--m�rz.c-r+m, RED \ tY. 91(I+AN MDN®f6!i®R.P LW 8fl tADmF Mti �. oxmwcmn snEStP1S� \ \\ 1 �� \ �y � �r�t- �da+m.uD•m,a,•-,.t am m-m- ,,g i y mmriwdos m �im�o W � �,Y•" —Qg.t ERE 6.mimamv¢mae�4➢mw ar YR'A1 ®1�m1 aka.,i YLTP39 BNlm T. f�QQ��am�� � • � �' �-�an',.fLL N®696• [YYq®�pM V,ID S'�pA'8 7) �amiimc�rae mr®� \ m:via mm ocvn m es mE Acw r��v a � �as 1 � �J' • � ®mv miss iwn,o�mo..m'd��sem us man am wan: _.�® " a¢ ♦ 1SVXLE �RESIDENCE W mDi AaA. !�• �•��•^--��"'�` / / ; I ayslessmc�sal Wsa.Iaaon..nmc Palm® W axZ l,+D}41c mm cues a eAUEraDO: I / a 1 narmr urt 1�D. /a I y f o wo l � aneam 1 a°C IIES FOR SEPIIO SYSTEM / p� n Esmm �+ 70 PQ1R p/'��/C PRDl1 PDPIT•A•PRg1 PENT•EI DFMdPY1W1 f / ZLit7 •m® PROVE L D B�/ [ w 'mo d f I BOARD OF I RUSTEES -TO.WN-OF-SOUTHOLD E C E D �t (� ASBULLT A q n RDeEmAe`EuuTc // i DATE MAR 17 Southold Town SHEET i Glenn Goldsmith,President �%OF SO(/ryO Town Hall Annex 'Nicholas Krupeki,Vice President hO 54376 Route 25 Eric Sepenoski P.O.Box 1179 Liz Oillooly 4 Southold,New York 11971 Joseph Finora Q Telephone(631) 765-1892 Fag(631) 765-6641 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD March 20, 2026 JMO Environmental Consulting PO Box 447 Quogue, NY 11959 RE: J. GEDDES PARSONS 515 STERLING STREET, FISHERS ISLAND SCTM#: 1000-10-9-3.1 Dear Mr. Just: The following action was taken by the Southold Town Board of Trustees at their Regular Meeting held on Wednesday, March 18, 2026: RESOLVED, that the Southold Town Board of Trustees APPROVE the Administrative Amendment to Wetland Permit#10005 and Coastal Erosion Permit#10005C for the as- built reconstruction of a 48' long bulkhead return located at the western side of the property and as-built construction of 4.9'-6'x 48.3' (varying width) concrete walk located immediately landward of reconstructed return; install an 8'x 6' drywell; saw cut and remove two portions of existing concrete walk and install two French drains to be connected to drywell; and to install a 10' wide vegetated non-turf buffer along the landward side of the retaining wall. Any other activity within 100' of the wetland boundary requires a permit from this office. This is not a determination from any other agency. If you have any questions, please call our office at (631) 765-1892. Sincerely, Glenn Goldsmith, President Board of Trustees ERM ST SITC•PIAN\PWG\6my N[c= 8 rag g 11 1 �Sp x3�� y � �n aaaa• R •o�oo eoaOR�fi' •. F •aao• '3 aeeae JIM M I I � , I M.0►AWbN � rrr555 z 10 Ile ` 1 R X +++111 ti y a R ,fir \ W / �a, k'am ti � Vicky _�\ / °� � •.• / �" IJ R r RECORDED Number of pages ' 2026 Jul 27 11:45t 40 AM UINCEN T PULE► CLERK OF t�'UFFULf�L OaK�►COUNT COUNTY ' This document will be public '� record. Please remove all 0 ,13 Social Security Numbers prior to recording. Deed/Mortgage Instrument Deed/Mortgage Tax Stamp Recording/Filing Stamps 31 FEES Page/Filing Fee Mortgage Amt. 1. Basic Tax Handling 20. 00 2. Additional Tax TP-584 Sub Total Notation Spec./Assit. or EA-52 17 (County) Sub Total ' S Spec./Add. EA-5217 (State) TOT.MTG.TAX R.P.T.S.A. Dual Town Dual County Held for Appointment Comm.of Ed. 5. 00 Transfer Tax a: Affidavit _ Mansion Tax Certified Co 1 ( � • 7 5 The property covered by this mortgage is py or will be improved by a one or two NYS Surcharg �:. •°''' 1 Other 5. 00 Sub Total 2' ' �`S family dwelling only. _� YES or NO Grand Total / If NO,see appropriate tax clause on page# of this instrument. 4 DistAt= 5775395 1000 01000 0900 003001 5 Community Preservation Fund Real Property R CSK A Consideration Amount $ Tax Service. 024ut,.ss CPF T D Agency Tax $ Verification Improved 6 Satisfactions/Discharges/Releases List Property Owners Mailing Address RECORD&RETURN TO: Vacant Land TD a-Co°T�pp«� b6ve Rk 3-erhPQc1 f tJ�l 1l gel TD TD Mail to: Judith A. Pascale, Suffolk County Clerk 7 Title Company Information 310 Center Drive, Riverhead, NY 11'901 Co.Name www.suffolkcountyny.gov/clerk Title# 8 Suffolk Counly Recor : * . & Endorsement Page This page forms part of the attached Deaca , n Q C'aoe nankS made by: (SPECIFY TYPE OF INSTRUMENT) The premises herein is situated in `4 teal mT.ro 1 SUFFOLK COUNTY,NEW YORK. TO In-the TOWN of So1� In the VILLAGE "a� or HAMLET of P 15 er 5, Ssko,k4 BOXES 6 THRU 8 MUST BE TYPED OR PkINTED IN BLACK INK ONLY PRIOR TO RECORDING OR FnJ NG. ia.a►a..►oiaav� v (over) PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? [Dyes*o IF YES,PROVIDE A COPY. Check Box After Reading: The owner/contractor/design professional Is responsible for all drainage and storm water Issues as provided by .Chapter 236 of the Town Code.APPLICATION is HEREBY MADE to the Building Department for the Issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings,' additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized Inspectors on premises and In buliding(s)for necessary Inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210AS of the New York State Penal Law. Application Submitted By(print name): /h71 97-4 A� uthorized Agent []Owner Signature of Applicant: Date: STATE OF NEW YORK) / SS: COUNTY Of 1� / /�1QM►45 �,, �17r�/U being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the /Y.�r eg% (Contractor,Agent,Corporate Offic ,4et ) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this /` day of !4424 ,20� ®04 Z� ary Public � ���zZzSG� PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) • (,� 44 � !!!)—residing at Ll+ Pam'-+r'� 'C.11/L �}•5. 1�'�.• 33`�ss do hereby authorize ��J �t/�+T�►4cViYi9 TL. to apply on m a to the To of Southold Building Department for approval as described herein. 3 . 11. Lz. Owner's Signature Date ` Print Owner's Name �. 2 Albert-Righter-Tittmann AIT' ARCHITECTS Date: 2 May 2024 To: Mike Verity Building Department Town Hall Annex Building 54375 Route 25 P.O.Box 1179 Southold NY 11971 From: Jacob Albert A,R&T Architects, Inc. Re: Kathryn&Geddes Parsons house 515 Sterling St. Fishers Island Suffolk Co. Tax Map 1000-10-9-3.1 Enclosed: Plans, elevations, structural plans Structural notes on cupola Revised Permit Drawing Changes A2.0: • Revised foundations for chimney hearths per structural drawings • Revised entry porch pier arrangement to agree with structural drawings A2.1: 0 Eliminated column in garage in front of garage door A2.2: e Reconfigured Main Bedroom 210 closet layout A2.3: 0 Added cupola for range hood exhaust A3.0: 0 Cupola shown in elevations e Revised Main Bedroom west dormer configuration 33.Union Street 4th Floor Boston, MA 02108 617451-5740 ARrarchitects.com w. Esther Hodges-LeClaire From: Helene Woodvine <helene@SiegelStructural.com> Sent: Tuesday, October 3, 2023 4:22 PM To: Esther Hodges-LeClaire Cc: Jacob Albert; 'Z&S Contracting,lnc.' Subject: RE: Parsons Cupola _... .7.., Caution!This message was sent from outside your organization. Allow sender I'Block sender Hi Esther, The cupola framing concept is good and we would expect to have corner posts that tie into attic framing. We will want to use Simpson hardware—either straps or holdowns to mechanically fasten the posts to framing. 44 posts are adequate and we'd want to use a Simpson LSTA24 strap with 12"onto post and 12" fastened to 2x12 below or a Simpson DTT1Z holdwon can be used to connect post to framing below. The holdown will require a double 2x member below to fasten the holdown. Simpson H2.5 hurrican ties should be used for rafter to wall plate connections. Best, Helene HELENE A.WOODVINE(she/her) Associate Principal, VP of Project Management 617.431.3513 From: Esther Hodges-LeClaire<EHLeClaire@artarchitects.com> Sent:Tuesday,October 3, 2023 12:56 PM To: Helene Woodvine<helene@SiegelStructural.com> Cc:Jacob Albert<JAIbert@artarchitects.com>; 'Z&S Contracting,inc.'<zandscontracting@gmail.com> Subject: RE: Parsons Cupola Hi Helene, Can you confirm receipt of this email?The contractor is eager to proceed with the cupola. -Esther ESTHER HODGES-LECLAIRE,AIA ART I Albert• Righter•Tittmann ARCHITECTS 33 Union Street Boston, MA 02108 1 - 617.451.5740 ARTarchitects.com Liu®® From: Esther Hodges-LeClaire Sent:Thursday,September 28,2023 1:53 PM To:'Helene Woodvine'<helene @SiegelStructural.com> Cc:Jacob Albert<JAI bert@a rta rchitects.com>; 'Z&S Contracting,Inc.'<zandscontractine@gmaiLcom> Subject: RE: Parsons Cupola Hi Helene, Checking to make sure you got this email. Have you had a chance to look at the proposed Cupola? Thanks, Esther ESTHER HODGES-LECLAIRE,AIA ART I Albert• Righter•Tittmann ARCHITECTS 33 Union Street Boston, MA 02108 617.451.5740 ARTarchitects.com From: Esther Hodges-LeClaire Sent:Wednesday,September 20,2023 12:41 PM To:'Helene Woodvine'<helene@SiegelStructural.com> Cc:Jacob Albert<JAlbert artarchitects.com>; 'Z&S Contracting,lnc.' <zandscontracting@gmail.com> Subject: Parsons Cupola Hi Helene, We've decided to add a cupola to the roof at Parsons. It will sit right where the two rooflines meet.Attached is a sheet of what we're proposing.We'd like to get your input on structural hold downs.We're thinking the corners would be 4x4 or 6x6 posts that go down through the roof and tie into the attic joists. Could you take a look at this and let us know if you see anything structurally we should be aware of? Thanks, Esther 2 ✓ 2_ E E A, R&T Architects, Inc. 2 202 33 Union Street,4`h floorP�. Boston MA 02108 T (617) 451-5740 t�Bui aF s gJJ'., ,; 22 April 2022 Amanda Nunemaker Building Department Town Hall Annex Building 54375 Route 25 P.O. Box 1179 Southold NY 11971 Re: Kathryn & Geddes Parsons house 515 Sterling St . Fishers Island Suffolk .Co. Tax Map 1000-10-9-3. 1 Dear Ms . Nunemaker: Thanks for reviewing the Building Permit application by Z&S Contracting for the Parsons house at Fishers Island. To ans er your questions : . Z&S will provide a disconnect letter from FI Utilities stating electric has been disconnected to dwelling. 2 . There is no natural gas on site. 3. See enclosed manufacturer' s specs for the Superior Wall foundation. 4 . We have noted on the Window Schedule which windows meet egress requirements according to NYS code. See enclosed page A5 . 1 . The Window Schedule references Plan pages A2 . 1 and A2 . 2 . 5. The emergency egress from the basement is a pair of doors, with each door 3' -0" wide x 6' -8" high. See enclosed page A5. 1, where Door #001 is described on the Door Schedule, and basement plan on page A2 . 0 . These doors take you outside, under the deck. From this space under the deck you then exit through a pair of doors in the under-deck screening. These doors are each 3' -0" wide x 7' -5" high. See enclosed elevation page A3 . 0 . Very truly yours, Jacob D. Albert Amanda Nunemaker Southold.Building Department Dear Amanda, my name is James Cushing, and I am the superintendent with the Fishers Island Electric company, I am writing to inform the Southold building department that the overhead 120/240-volt service @ 515 Sterling St has been disconnected and removed from the dwelling on 4/19/22 Best regards, James Cushing Jcushing(cDfiuc.net 860-333-4799 NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION Division of Environmental Permits.Region 1 SUNY n.Stony Brook.50 Clrcle Road.Stony Brook,NY 11790 P:{631)44.0:3.651 F:(6ai)A44.0360 LETTER OF NO-JURISDICTION October 8, 2021 J. Geddes Parsons Re: Application ID 1-4738-00260/00004 C/O Parsons Capita[ Management 515 Sterling Street 10 Weybosset Street, Suite 1000 Fishers Island Providence, RI 02903 SCTM 4 1000-10-9-3.1 ARNO-DEP Dear Applicant: Based on the information your agent submitted and additional New York State Department of Environmental Conservation (DEC) information, DEC has made the following determination. The portion of the referenced property landward of the existing functional concrete seawall more than 100 feet in length and originally constructed prior to 8/2011977, as evidenced on a property survey of a portion of the property dated December 30., 1975 and a 1962 aerial. photograph, is beyond the jurisdiction of Article 25 Tidal Wetlands. Therefore, in accordance with the current.Tidal Wetlands Land Use Regulations (6 NYCRR Part 661), no permit is required for work. occurring at the property landward. of the jurisdictional boundary described above. Please be advised however, that no construction, sedimentation, discharge, or disturbance of any kind may take place seaward of the jurisdictional boundary without a permit. It is your responsibility to ensure that all necessary precautions are taken to prevent any sedimentation or other alteration or disturbance to the ground surface or vegetation within DEC's jurisdiction which may result from your project. Such precautions may include, maintaining an adequate, work area .(i.e. a 15' to 20' wide construction area) or erecting a temporary fence, barrier, or hay bale berm. Please be further advised that this letter does not relieve you of the responsibility of obtaining any necessary permits or approvals from local municipalities or other agencies. Very trul yours, Susan V. Ackerman Regional Permit Adrninistrator SVA/rrlrp CC: .1M0 Environmental Consulting BMHP File �1EWYORK ' Department of __w`+ A:•:,::.•, Environmental - Conservation Generated by REScheck-Web Software 9 Compliance Certificate Project Parsons - Sterling Street House Energy Code: 2018 IECC Location: Southold, New York Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 4,592 ft2 Glazing Area 16% Climate Zone: 4 (5572 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: Sterling Street Jacob Albert Fishers Island, New York 06390 Albert, Righter&Tittmann Architects, Inc 262 Washington St Floor 2 Boston, MA 02108 617-515-4965 jalbert@artarchitects.com trade-offCompliance: Passes using UA Compliance: 15.4%Better Than Code Maximum UA: 1082 Your UA: 915 Maximum SHGC: 0.40 Your SHGC: 0.06 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Envelope Assemblies Prop.Gross Area Cavity Cont. Req. Prop. Perimeter R-V Ceiling: Flat Ceiling or Scissor Truss 3,783 56.0 0.0 0.024 0.026 91 98 Wall:Wood Frame, 16"o.c. 5,154 38.5 0.0 0.044 0.060 174 237 Door 1: Solid Door(under 50%glazing) 222 0.200 0.320 44 71 Door: Glass Door(over 50% glazing) 101 0.310 0.320 31 32 SHGC: 0.10 Window: Wood Frame 876 0.310 0.320 272 280 SHGC: 0.05 Wall 1: Insulated Concrete Forms 878 15.0 0.068 0.098 56 81 Door 2: Solid Door(under 50%glazing) 40 0.100 0.320 4 13 Window 1: Wood Frame 10 0.310 0.320 3 3 SHGC: 0.05 Floor:All-Wood Joist/Truss 3,443 21.0 0.0 0.044 0.047 151 162 Floor 1:All-Wood joist/Truss 343 56.0 0.0 0.019 0.047 7 16 Project Title: Parsons - Sterling Street House Report date: 12/23/21 Data filename: Page 1 of10 5 Prop.Gross Area Cavity Cont. Prop. Perimeter Basement: Insulated Concrete Forms Wall height: 8.5' 1,283 15.0 0.054 0.059 69 76 Depth below grade: 7.0' Insulation depth: 8.5' Crawl: Insulated Concrete Forms Wall height: grade: 4.9'Depth below grade: 428 15.0 0.065 0.065 13 13 Insulation depth: 5.5' Compliance Statement. The proposed building design described here is consistent with the building plans,specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name-Title Signature Date Project Title: Parsons-Sterling Street House Report date: 12/23/21 Data filename: Page 2 of10 ti REScheck Software Version : REScheck-Web Inspection Checklist Energy Code: 2018 IECC Requirements: 100.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section r ,; Plans Verified Field Ver�f�ed Pre Inspection/Plan Review Value Value Complies? Comments/Assumptions & Re 103.1, !Construction drawings and r ' E]Complies 'Requirement will be met. 103.2 !documentation demonstrate El Not [PR1]1 energy code compliance for the I building envelope.Thermal 4 ❑Not Observable ` J ;envelope represented on :❑Not Applicable construction documents. > , 103.1, :Construction drawings and sxf❑Complies Requirement will be met. 103.2, documentation demonstrate sEl Does Not I 403.7 energy code compliance for 'I ! (PR3]1 lighting and mechanical systems. t ❑Not Observable Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. k r 302 ]; Heating and cooling equipment is':. Heating: i Heating: ❑Complies 'Requirement will be met. 403.7-...;.,.._., sized per ACCA Manual S based Btu/hr ' Btu/hr ❑Does Not [PR2j? on loads calculated per ACCA Cooling: Cooling: ❑Not Observable Manual) or other methods Btu/hr Btu/ approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) Jg:2`I Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Parsons - Sterling Street House Report date: 12/23/21 Data filename: Page 3 of10 Section ,, Plans Verifiled; Fieltl:Verified Founda#ion Inspection Value Value Complies? Comments/Assumptions &zReq �D 402.1.1 Conditioned basement wall :' R- R- ;❑Complies .See the Envelope assemblies [F04]1 insulation R-value.Where interior R_ R_ ❑Does Not table for values. insulation is used,verification may need to occur during ❑Not Observable Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall . ❑Complies Requirement will be met. [F05]1 insulation installed per = ❑Does Not ;manufacturer's instructions. i ❑Not Observable ❑Not Applicable 402.2.9 1 Conditioned basement wall ft i ft ❑Complies iSee the Envelope assemblies [F06]1 insulation depth of burial or ❑Does Not :table for values. distance from top of wall. ❑Not Observable ❑Not Applicable 402.2.11 Unvented crawl space wall R- R- ❑Complies See the Envelope assemblies [F07]1 :insulation R-value. R_ R_ ❑Does Not table for values. J , ;❑Not Observable . ❑Not Applicable 303.2 Unvented crawl space wall ryr °❑Complies Requirement will be met. [F08]1 insulation installed per I x `❑Does Not manufacturer's instructions. ' ❑Not Observable i k ❑Not Applicable 402.2.11 i Unvented crawl space continuous -�❑Complies Requirement will be met. [F09]1 vapor retarder installed over ❑Does Not exposed earth,joints overlapped ❑Not Observable by 6 in.and sealed, extending at i :least 6 in. up and attached to the �,❑Not Applicable wall. � ) 402.2.11 Unvented crawl space wall in. in. ❑Complies ;see the Envelope assemblies [FO10]1 insulation depth of burial or ❑Does Not 'table for values. !distance from top of wall. ;❑Not Observable ❑Not Applicable 303 21 ,;A protective covering is installed a❑Complies ;Requirement will be met. [FOIl]z F to protect exposed exterior ❑Does Not insulation and extends a minimum of 6 in. below grade. ! '❑Not Observable ' z K ❑Not Applicable 403 9 in Snow-and ice-melting system ;❑Complies Requirement will be met. [F012]? controls installed. ' Does Not K ` '❑Not Observable _❑Not Applicable Additional Comments/Assumptions: 11 High Impact (Tier 1) -2y Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Parsons-Sterling Street House Report date: 12/23/21 Data filename: Page 4 of10 Section Plans Verified F�eid Verifed Framing i Rough In Inipe Jlon i Complies? Comments%Assumptions UalUe \ialue. :.., 402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FRl]1 ;❑Not Observable ' ❑Not Applicable 402.1.1, 'Glazing U-factor(area-weighted U- U- ❑Complies see the Envelope assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.5 .❑Not Observable [FR2]1 ❑Not Applicable 303.1.3 U-factors of fenestration products r ` t a 3 z;❑Complies Requirement will be met. [FR4]1 :are determined in accordance [ t a❑Does Not ;with the NFRC test procedure or ; ;taken from the default table. , r' �r❑Not Observable f ``- ❑Not Applicable 402.4.1.1 :Air barrier and thermal barrier } ❑Complies ;Requirement will be met. [FR23]1 'installed per manufacturer's s ❑Does Not instructions. ; s ' '❑Not Observable >;❑Not Applicable 402.4.3 Fenestration that is not site built } ` UComplies :Requirement will be met. [FR20]1 is listed and labeled as meeting s s El Does Not AAMA/WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC ❑Not Observable ' 400 that do not exceed code li ❑Not Applicable limits. ; 402 4 2 4 IC-rated recessed lighting fixtures ❑Complies ;Requirement will be met. [FRl6] sealed at housing/interior finish ! Does Not f ;° and labeled to indicate :52.0 cfm leakage at 75 Pa. 4r r ?❑Not Observable _ `❑Not Applicable 403.3.1 ;Supply and return ducts in attics ; o❑Complies Exception: Ducts located [FR12]1 insulated>= R-8 where duct is I - ]Does Not ;completely inside the 3 inches in diameter and >= i } building envelope. R-6 where< 3 inches. Supply and ,; ,❑Not Observable . return ducts in other portions of i ,❑Not Applicable 'the building insulated >= R-6 for a Idiameter>= 3 inches and R-4.2 i 1 :for< 3 inches in diameter. 403.3.2 IDucts,air handlers and filter ;: ❑Complies Requirement will be met. [FR13]1 boxes are sealed with r : ❑Does Not ;joints/seams compliant with ^❑Not Observable :International Mechanical Code or < International Residential Code, as t ,, ` r,.❑Not Applicable applicable. 403,3.5 . :Building cavities are not used as r( ❑Complies Requirement will be met. [FR15]3 :ducts or plenums. y . jj❑' Does Not E 3 '4 t 7� S 1 3" ❑Not Observable ' ❑Not Applicable 1 High Impact (Tier 1) 2 Medium Impact(Tier 2) 1 3 ILow Impact(Tier 3) Project Title: Parsons - Sterling Street House Report date: 12/23/21 Data filename: Page 5 of10 Section Plans Verified F�eld.Venfied Framing/Rough In Inspection Complies? Comments/Assumptions AD , _ ' Value, Value. 4.01- .J- i Ducts declared to be within the ❑Complies :Requirement will be met. (F.213 3 !conditioned space are either 1) El Does Not completely within the continuous : air barrier and within the building ❑Not Observable ;thermal envelope, 2) buried . _ ;❑Not Applicable within ceiling insulation in f .;accordance with Section R403.3.6 and the air handler is k� located completely within the ; j continuous air barrier and within ;the building thermal envelope and the duct leakage is <= 1.5 cfm/100 square feet of ., r, conditioned floor area served by f N the duct system, or 3)the ceiling ! ;: S insulation R-value installed !against and above the insulated !duct>=to the proposed ceiling insulation R-value, less the R- ;, value of the insulation on the HVAC piping conveying fluids R- R- ❑Complies Requirement will be met. (FIR 1;7]z�t;; }above 105 QF or chilled fluids ! ❑Does Not i below 55 QF are insulated to>_R- ❑Not Observable ❑Not Applicable 403.4.1 'Protection of insulation on HVAC f +` 't❑Complies Requirement will be met. [FR24]1 piping. s j❑Does Not ❑Not Observable I ry❑Not Applicable Hot water pipes are insulated to R- R- ❑Complies Requirement will be met. ❑Does Not '❑Not Observable ❑Not Applicable .;;Automatic or gravity dampers are i r* ; y';❑Complies ,Requirement will be met. [FR19]2 f installed on all outdoor air 1 +; ❑Does Not +intakes and exhausts. ` ❑Not Observable . s ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title; Parsons - Sterling Street House Report date: 12/23/21 Data filename: Page 6 of10 Sectilon r a Plarfs Verified F�eld`Uerif�ed lnsulAilonInspection Value Value Complies? Comments/Assumptions .&.Req ID 303I All installed insulation is labeled ': >`❑Complies Requirement will be met. [1N13]z or the installed R-values ❑Does Not 4 provided. V , ❑Not Observable r ❑Not Applicable 402.1.1, Floor insulation R-value. R- R- '❑Complies ,See the Envelope Assemblies 402.2.6 ❑ Wood ❑ Wood :❑Does Not table for values. [IN1]1 ❑ Steel ❑ Steel ;❑Not Observable t ;❑Not Applicable ; 303.2, Floor insulation installed per r y 'Ekomplies !Requirement will be met. 402.2.8 manufacturer's instructions and k ❑Does Not [IN2]1 in substantial contact with the ' iJ 'underside of the subfloor, or floor ' 4 ❑Not Observable framing cavity insulation is in i < ``❑Not Applicable contact with the top side of f sheathing,or continuous insulation is installed on the ; underside of floor framing and { 'extends from the bottom to the r top of all perimeter floor framing members. 402.1.1, Wall insulation R-value. If this is a R- R- ;❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood :❑ Wood ❑Does Not :table for values. 402.2.E wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable [IN3]1 exterior,the exterior insulation .requirement applies (FR10). ❑ Steel ❑ Steel ❑Not Applicable ; 303.2 Wall insulation is installed per ( ❑Complies `Requirement will be met. [IN4]1 manufacturer's instructions. } ❑Does Not >r❑Not Observable . ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) ,2,°.; Medium Impact(Tier 2) 3. Low Impact(Tier 3) Project Title: Parsons - Sterling Street House Report date: 12/23/21 Data filename: Page 7 of10 Section ` ' Plans Verified Field Verified ti# 4 Final Inspection Provisions Complies? Comments/Assumptions Value Value 402.1.1, Ceiling insulation R-value. R- R- -❑complies See the Envelope Assemblies 402.2.1, ;❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, ❑ Steel ❑ Steel ;❑Not Observable 402.2.E[Fllj °❑Not Applicable 303.1.1.1, :;Ceiling insulation installed per r ?❑Complies Requirement will be met. 303.2 'manufacturer's instructions. ,❑Does Not [FI2]1 ;Blown insulation marked every Not Observable 300 ftz. ❑ ' ❑Not Applicable 402 2Z �,Vented attics with air permeable 4❑Complies Exception: Requirement is [FI22] insulation include baffle adjacent I T❑Does Not not applicable. 4 :,,,,,to soffit and eave vents that ! ' -❑Not Observable extends over insulation. t ❑Not Applicable licable 402.2.4 Attic access hatch and door R- R- ❑Complies Requirement will be met. [FI3]1 insulation ?R-value of the `❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies Requirement will be met.— [FI17]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable , ❑Not Applicable 403.3.3 ;Ducts are pressure tested to cfm/100 cfm/100 ❑Complies Exception:All ducts and air [FI27]1 :determine air leakage with ftz ftz ❑Does Not handlers are located within either: Rough-in test:Total ❑Not Observable conditioned space. ;leakage measured with a pressure differential of 0.1 inch a ❑Not Applicable w.g. across the system including :the manufacturer's air handier enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handier enclosure. _ 403.3.4 1 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies Requirement will be met. [FI4]1 cfm/100 ft2 across the system or ; ft2 ftz ❑Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in ❑Not Observable tests,verification may need to ❑Not Applicable !occur during Framing Inspection. 403.3.2.1 'Air handler leakage designated ..,-",❑Complies — ;Requirement will be met.^ [FI24]1 by manufacturer at<=2%of ❑Does Not design air flow. r ❑Not Observable :`❑Not Applicable 403 1 1 .;Programmable thermostats = ❑Complies Requirement will be met. [FI9]? ;installed for control of primary _. ❑Does Not heating and cooling systems and 'initially set by manufacturer to ❑Not Observable vcode specifications. ❑Not Applicable 403 1 2' 'Heat pump thermostat installed ❑Complies ;Requirement will be met. [FIlO]� i on heat pumps. ° ❑Does Not ❑Not Observable i :.❑Not Applicable 403 5 1 Circulating service hot water ❑Complies 'Requirement will be met. [Fllljz ° '• systems have automatic or Y ❑Does Not ;accessible manual controls. r x r ❑Not Observable '`; ❑Not Applicable V. 1 1 High Impact (Tier 1) :2 J Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Parsons- Sterling Street House Report date: 12/23/21 Data filename: Page 8 of10 Section h ? puns Verified Field`Verified Final Inspection Provisions w Compl�es� Comments/Assumptions• & iteq 4D ' '` F y d r Value Value .. .,,k: 403 61 All mechanical ventilation system s❑Complies ;Requirement will be met. [FI25]z ifans not part of tested and listed i x El Does Not HVAC equipment meet efficacy 4 and air flow limits per Table '—]Not Observable R403.6.1. ' ;a ❑Not Applicable 403`2. ;Hot water boilers supplying heat '❑Complies Requirement will be met. [FI261z through one-or two-pipe heating ", ^y;,° r y ❑Does Not systems have outdoor setback } > control to lower boiler water i ' ❑Not Observable temperature based on outdoor .'•❑Not Applicable temperature. 403 5 11 n Heated water circulation systems { ❑Complies Requirement will be met. [FI28]z ?have a circulation pump.The t; . f❑Does Not ;system return pipe is a dedicated return pipe or a cold water supply ❑Not Observable pipe. Gravity and thermos- ❑Not Applicable s syphon circulation systems are t fY not present.Controls for t w s circulating hot water system F = y ;pumps start the pump with signal for hot water demand within the i x occupancy.Controls automatically turn off the pump i when water is in circulation loop =' s is at set-point temperature and I F no demand for hot water exists. 403 5 12 ;Electric heat trace systems ❑Complies Requirement will be met. [FI291. ` ' ';comply with IEEE 515.1 or UL ❑Does Not 515.Controls automatically = ;adjust the energy input to the y r ;❑Not Observable ' heat tracing to maintain the ❑Not Applicable 7 s t vt s F ,err rt s; desired water temperature in the * } . x ,piping. 1", Demand recirculation water ,r❑Complies 'Requirement will be met, [FI30]2�a systems have controls that ❑Does Not ki manage operation of the pump s 'and limit the temperature of the `,,[]Not Observable ' { -jwater entering the cold water ;' ?❑Not Applicable piping to <= 104QF. 403 54 Drain water heat recovery units `❑Complies 'Requirement will be met. [FI31]? }tested in accordance with CSA ; ❑Does Not B55.1.Potable water-side pressure loss of drain water heat ❑Not Observable recovery units < 3 psi for ❑Not Applicable individual units connected to one a ° x* or two showers. Potable water- side pressure loss of drain water H heat recovery units < 2 psi for 1 f individual units connected to three or more showers. } 404.1M1 ;90%or more of permanent ❑Complies Requirement will be met. [FI6]1 'fixtures have high efficacy lamps q ❑Does Not EJ YS� i •'�i ❑Not Observable t `❑Not Applicable 4041,3 "Fuel gas lighting systems have = ?❑Complies :Requirement will be met. [FI23j3' I no continuous pilot light. i u El Does Not I ❑Not Observable [ ;T. ❑Not Applicable 1`3 Compliance certificate posted, u'❑Complies Requirement will be met. 40 [FI7]Z x y ❑Does Not � t ,x � ?❑Not Observable f ❑Not Applicable 1 High Impact(Tier 1) J�',:..2%J Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Parsons - Sterling Street House Report date: 12/23/21 Data filename: Page 9 of10 Section fPlahs Verif�etl Fie1dVerifiel 11661Provision's Complies?:. CammentsIAssumptions Value 30#33 Manufacturer manuals for i k t❑Complies ERequirement will be met. [FI18] !mechanical and water heating ❑Does Not systems have been provided. E `EINot Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) >2z,; Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Parsons - Sterling Street House Report date: 12/23/21 Data filename: Page 10 of10 r 2018 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 38.50 Below-Grade Wall 15.00 Floor 21.00 Ceiling / Roof 56.00 Ductwork (unconditioned spaces): Door Rating Window 0.31 0.05 Door 0.20 0.10 Cooling:Heating & Heating System: Cooling System: Water Heater: Name: Date: Comments N IM • , ICC-ES Evaluation Report ESR-1662 Reissued August 2020 Revised February 2021 This report is subject to renewal August 2022. www.icc-es.org 1 (800) 423-6687 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 03 00 00—CONCRETE Attributes verified: Section: 03 41 00—Precast Structural Concrete ■ See Section 3.0 REPORT HOLDER: 2.0 USES SUPERIOR WALLS OF AMERICA, LTD. The Superior Walls Xi and Xi Plus Precast Concrete Foundation Walls (including basement walls) are used to EVALUATION SUBJECT: support wood frame construction. SUPERIOR WALLS Xi AND Xi PLUS PRECAST 3.0 DESCRIPTION CONCRETE FOUNDATION WALLS The Superior Walls Xi and Xi Plus Precast Concrete ADDITIONAL LISTEES: Foundation walls are formed from 5,000 psi (34.4 MPa) compressive strength normal-weight concrete that contains SUPERIOR WALLS BY ADVANCED CONCRETE synthetic fibers. SYSTEMS,INC. Superior Walls Xi and Xi Plus Precast Concrete Foundation Walls consist of a 13/4-inch-thick (44 mm) SUPERIOR WALLS OF CENTRAL VIRGINIA exterior face shell, monolithically cast with 101/4-inch-wide (260 mm) top and bottom bond beams, and 21/4-inch-by- SUPERIOR WALLS BY COLLIER FOUNDATION 71/2-inch (57 mm by 190.5 mm) concrete studs at SYSTEMS INC. 24 inches(610 mm)on center. SUPERIOR WALLS OF EAST TENNESSEE The only difference between the Xi and Xi Plus is that the shell is bonded to various combinations of rigid foam SUPERIOR WALLS SYSTEMS, LLC boards on the inside face. For the the Xi product,there are DBA: SUPERIOR WALLS OF NORTH CAROLINA three insulation options: the first is 21/2-inch-thick (63.5 mm) rigid cellular polystyrene; the second option is SUPERIOR WALLS OF NEW JERSEY an insulation assembly consisting of 2-inch (50.8 mm) rigid cellular polystyrene and a 1/2-inch (12.7 mm) layer of SUPERIOR WALLS OF UPSTATE NEW YORK polyisocyanurate insulation; and the third option is an insulation assembly consisting of 11/2-inch (38.1 mm) rigid SUPERIOR WALLS BY WEAVER PRECAST cellular polystyrene and a 1-inch (25.4 mm) layer of polyisocyanurate insulation. The Xi Plus product consist of GREAT LAKES SUPERIOR WALLS a 5-inch insulation assembly consisting of 41/2-inch (114.3 mm) rigid cellular polystyrene and a 1/2-inch 1.0 EVALUATION SCOPE (12.7 mm) layer of polyisocyanurate insulation on the inside face for the Xi Plus. Each stud is wrapped with Compliance with the following codes: 1-inch-thi6k(25.4 mm) expanded polystyrene insulation on ■ 2016, 2015, 2012, 2009 and 2006 International Building three exposed sides and faced with a galvanized steel Code®(IBC) channel for interior finish fastening. Chase openings with knockouts are provided in each stud for plumbing and ■ 2018, 2015, 2012, 2009 and 2006 International electrical wiring. All insulation is factory.installed to the Residential Code®(I RC) precast concrete walls and must be as described in Properties evaluated: Superior Walls'approved quality control documentation. ■ Structural Panels are available in heights of 4 .feet (1219 mm), ■ Fire-resistance rating 8 feet 2 inches (2489 mm), 9 feet. (2743 mm) and 10 feet ■ Surface burning characteristics (3048 mm), with corresponding weights of 170, 303, 329 and 361 lb/ft (253, 451, 490 and 537 kg/m), respectively. ■ Dampproofing The panels are available in various lengths. See Figures 1 ■ Thermal Barrier and 2. /CC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as to any finding or other matter in this report,or as to any product covered by the report. Copyright©2021 ICC.Evaluation Service,I.I.C.All rights reserved. Page 1 of 5 ESR-1662 I Most Widely Accepted and Trusted Page 2 of 5 >> , • The attributes of the wall panels have been verified as beams, to transfer loads induced by lateral loads in the conforming to the provisions of (i) CALGreen Sections plane of the wall, is limited to 1,500 Ibf (6675 N). See A4.404.3.3 for premanufactured building systems; (ii) ICC Figure 4 for typical details. 700-2015 and ICC 700-2012 Section 601.5 and 11.601.5 Details involving openings in the foundation walls have for prefabricated components; and (iii) ICC 700-2008 not been evaluated and are beyond the scope of this Section 601.5 for prefabricated components. Note that report. decisions on compliance for those areas rest with the user of this report. The user is advised of the project-specific The Superior Xi and Xi Plus walls must be laterally provisions that may be contingent upon meeting specific supported at the top and bottom of the panels. conditions, .and the verification of those conditions is 4.2 Fire-resistance-rated Wall Construction: outside the scope of this report. These codes or standards often provide supplemental information as guidance. With the addition of two layers of 5/a-inch(15.9 mm)Type X 4.0 DESIGN AND INSTALLATION gypsum wallboard complying with ASTM C1396, attached to the stud facing in accordance with the applicable 4.1 Design Details: code, Superior Walls Xi and Xi Plus walls with a Backfill material must not exceed 100 Ibf/ft2/ft maximum allowable axial compressive load of 3,000 Ibf/ft (1602 kg/m2/m) equivalent fluid'pressure for the 4-foot (43 779 N/m) (including ledger loads) have a two-hour (1219 mm), 8-foot-2-inch (2489 mm), 9-foot (2743 mm) fire-resistance rating. and 1046ot tall (3048 mm) Superior Walls. The walls have 4.3 Dampproofing: a combined (ledger plus wall loads above the foundation wall) maximum allowable axial compressive load of Superior Walls Xi and Xi Plus walls have been evaluated 7,500 Ibf/ft(109,453 N/m). as an alternative method of providing foundation wall Use of Superior Walls Xi and Xi Plus walls with a dampproofing; therefore, no additional dampproofing is brick ledge is limited to an allowable load of 2,900 Ibf/ft required. (42 320 N/m) on the brick ledge, which is to be considered 4.4 Thermal Barrier: as part of the allowable load of the wall noted in this section. A code-prescribed thermal barrier separating the foam plastic from the interior of the building is not required Above-grade foundation stem wall applications in which based on testing conducted in accordance with Section negative transverse loads (such as leeward side wind 2603.9 of the 2018, 2015, 2009, and 2606 IBC (Section pressure) in accordance with the applicable code are 2603.10 of the 2012 IBC) and Section R316.6 of the IRC developed, must be limited to applications where. the (Section R314.6 for the 2006 IRC). negative design wind pressure does not exceed,80 psf (3.83 kN/m2). Above-grade foundation stem wall 4.6 Installation Details: applications in which positive transverse wind loads, in Superior Walls Xi and Xi Plus walls must be installed in accordance with the applicable code, are developed must accordance with this report and the design details and be limited to applications where the allowable wind calculations, as noted in Section 5.5 of this report. pressure does not exceed 155 psf(7.42 Mm2). The allowable racking shear load on the Superior Xi and Construction details noted in Superior Walls documents Xi Plus foundation walls is limited to a maximum of 500 pif such as the Builder Guideline Booklet, have not been (7300 N/m). Construction using the Superior Walls Xi and evaluated and are beyond the scope of this report. Xi Plus system is limited to those Seismic Design 5.0 CONDITIONS OF USE Categories specified in Section 5.7. The Superior Walls Xi and Xi Plus Precast Concrete Use of Superior Walls Xi and Xi Plus walls with beam Foundation Walls described in this report comply with, or pockets utilizing two support studs is limited to applications are suitable alternatives to what is specified in, those where the maximum allowable load applied to the beam codes listed in Section 1.0 of this report, subject to the pocket does not exceed 16,000 Ibf (71 200 N) for a following conditions: 10-foot-high (3048 mm) panel and 13,000 Ibf (57 800 N) for shorter heights. Other beam pocket configurations are 5.1 Superior Walls Xi and Xi Plus walls must be outside the scope of this report. manufactured, identified and installed in accordance Beam pockets must be designed and constructed in with this report and the information required by accordance with the details, dimensions and specific Section 5.5 of this report. loading limitations given in the engineered design 5.2 Where underground water investigation, required by drawings. See Figure 3 for typical beam pocket details. the applicable code, indicates that a hydrostatic Design of the footing supporting Superior Walls Xi and Xi pressure condition exists, the foundation wall must be . Plus walls must be in accordance with the applicable code. waterproofed in accordance with the applicable code. The footing must extend below'the frost line of the locality, Evaluation of the waterproofing material is outside the as required by the applicable code. scope of this report. For jurisdictions adopting the IRC, installation of Superior 5.3 Connection of adjacent Superior Walls Xi and Xi Plus Walls Xi and Xi Plus walls on gravel footings is permitted walls must be inspected to verify application of the as noted in IRC Section R401.2, provided the construction sealant and bolts in accordance with the submitted details comply with Section R403.4 and the details noted in design drawings. Table 1 of this report. 5.4 Soil capacity of the site must be consistent with the The capacity of the bolted connection at the top and requirements of the applicable code. For jurisdictions bottom of the panels, using '/2-irich-diameter-by-2'/2-inch- adopting the IRC, the soil capacity of the site, in lieu long (12.7 mm by 63.5 mm) hex head bolts through the of a complete geotechnical evaluation, must be bond beams and a 1/2-inch-diameter-by-51/2-inch-long assumed to have the load-bearing values specified in (12.7 mm by 140 mm) hex head bolt through the footing IRC Table R401.4.1. ESR-1662 1 Most Widely Accepted and Trusted Page 3 of 5 5.5 Design calculations and drawings must be submitted 7.0 IDENTIFICATION to the code official for approval. The documents must 7.1 Each Superior Walls Xi and Xi Plus precast panel be prepared by a registered design professional must bear a label with the evaluation report number where required by the statutes of the jurisdiction in (ESR-1662). The label must be attached at mid- which the project is to be constructed. The design height, near the center of each wall panel. calculations and details must address, at a minimum, Additionally, each project must have at least one label the following: on the foam insulation of one panel noting the name ■ Details of waterproofing, if applicable. of the manufacturer,the name of the installer, and the ■ Depth of footing and footing specifications manufactured and installation dates. consistent with this report. 7.2 The report holder's contact information is the ■ Investigation of resistance to overturning and uplift following: forces. SUPERIOR WALLS OF AMERICA, LTD. ■ Details for lateral support of the top and bottom of 937 EAST EARL ROAD Superior Walls Xi and.Xi Plus walls. NEW HOLLAND, PENNSYLVANIA 17557 (800)452-9255 ■ Verification that the loading requirements at the www.superiorwalls.com jobsite do not exceed the allowable .loads and details (including the foundation details) noted in 7.3 The additional listees' contact information is the Section 4.1 of this report. The calculations must following: include verification that the combined loading SUPERIOR WALLS BY ADVANCED CONCRETE conditions, such as out-of-plane and vertical loads, SYSTEMS,INC. do not exceed the allowable loads noted in this 55 ADVANCED LANE report. MIDDLEBURG, PENNSYLVANIA 17842 5.6 Installation must be done by Superior Walls-certified SUPERIOR WALLS OF CENTRAL VIRGINIA installers. 10101 SUPERIOR WAY 5.7 Superior Walls Xi'and Xi Plus walls used as lateral AMELIA,VIRGINIA 23002 force-resisting systems are limited to Seismic Design SUPERIOR WALLS BY COLLIER FOUNDATION Category A or B under the IBC and to Seismic Design SYSTEMS INC. Category A, B or C under the IRC. 1500 ELLSWORTH AVENUE,SUITE 210 5.8 Superior Walls must be manufactured at the locations HEIDELBERG, PENNSYLVANIA 15106 noted under "Additional Listees" in this report, in SUPERIOR WALLS OF EAST TENNESSEE accordance with the Superior Walls of America, Ltd., 10144 SPARTA HIGHWAY Quality Assurance Manual, dated September 2014, ROCK ISLAND,TENNESSEE 38581 and with inspections by ICC-ES. SUPERIOR WALLS SYSTEMS,LLC 6.0 EVIDENCE SUBMITTED DBA: SUPERIOR WALLS OF NORTH CAROLINA 6.1 Data in accordance with the ICC-ES Acceptance 3570 SOUTH MAIN STREET Criteria for Foam Plastic Insulation (AC12), dated SALISBURY, NORTH CAROLINA 28147 June 2015(Editorially revised May 2016), including a SUPERIOR WALLS OF NEW JERSEY report of a fire test in accordance with 2603.9 of the 92 REESE ROAD 2015, 2009, and 2006 IBC (Section 2603.10 of the MILLVILLE, NEW JERSEY 08332 2012 IBC). SUPERIOR WALLS OF UPSTATE NEW YORK 6.2 Results of water permeability tests conducted in 7574 EAST MAIN ROAD accordance with ASTM E96. LIMA, NEW YORK 14485 6.3 Data in accordance with the ICC-ES Acceptance SUPERIOR WALLS BY WEAVER PRECAST Criteria for Concrete Floor, Roof and Wall Systems 824 EAST MAIN STREET and Concrete Masonry Wall Systems (AC15), dated EPHRATA, PENNSYLVANIA 17522 February 2010 (Editorially revised February 2019); including reports of beam pocket tests. GREAT LAKES SUPERIOR WALLS 4555 134TM AVENUE 6.4 Report of fire-resistance tests conducted in HAMILTON,MICHIGAN 49419 accordance with ASTM El 19. ESR-1662 1 Most Widely Accepted and Trusted Page 4 of 5 S� TABLE 1—MINIMUM DEPTH OF CRUSHED STONE FOOTING(inches) SOIL TYPE AND LOAD BEARING CAPACITY(psf) CONSTRUCTION TYPE 1,500 2,000 3,000 (Assumed Wall Loading) SC,GC,SM,GM 4,000 MH,CH,CL,ML SP,SW GP,GW Conventional Light-frame Construction 1-story (1,100 pounds per linear foot) 4 4 4 4 2-story (1,800 pounds per linear foot) 4 4 4 4 3-story (2,900 pounds per linear foot) 12' 8 4 4 Masonry Veneer over Light-frame Construction 1-story (1,500 pounds per linear foot) 4 4 4 4 2-story (2,700 pounds per linear foot) 10' 6 4 4 3-story (4,000 pounds per linear foot) 201 12' 6 4 For SI: 1 inch=25.4 mm, 1 psf=0.0479 kN/m2, 1 plf=14.6 N/m. 'Stone must be vibrated in a mabmum 8-inch lifts. y.IATMtAL S@TP`PORTBY ,f 1,51 S AIMR BiOCMG 61ii )t33t JACY S °` AS SPOCIFIE OY A8 t>9$CRMEQDV cmMUCTION omumm S TMS " ifj t i g1g s .C111ASE OPEtND(O > :1 f (TYPICAL) - � sA lit INCH FACELI. IN 24 II+iCWS S?:V t"A. Al 4ei 11 ,�,,r Ell, K. E�r .ram-CrA LVAN�le'�I 0 a r � " a 3 i k .A .'.. P zz FOAM PtM= INSULATtON fir{=tl}��{�+}/y pW ��y y��} �r FyOQK.,..Q.A�11QNif�3yrl,p�vXAG6 y�,9,yy���Syyy.�y�q.,y�� �f7//w�{1SFEiraFIXw8y . Y FIGURE 1—TYPICAL SUPERIOR WALL VERTICAL SECTION DETAIL • ESR-1662 I Most Widely Accepted and Trusted Page 5 of 5 E>> << (LXi)vltttflt} IY4, i'H7ACBSH1U „�.� FOAM PLASJfICINSULA'FI02v { GALV'1 NMM SITU VACtl G {fi�Pf'�fKIOIi FIGURE 2—TYPICAL SUPERIOR WALL HORIZONTAL SECTION DETAIL 4,� T I FIGURE 3—TYPICAL BEAM POCKET DETAIL IN I I�t'l"Il t°It i 1 t1 0°°t ti!°t 9 11 tY l 3t 1°1 it II It i" Y i °°I u tN i trill) r t t i I i+ r t o in ° 1 t i ii p t i� r pp t i.. uu 12 alrtll l«°t [ tl li �f 15! it tl 1 it 1 1 IM l! it t 1 C 1!.Y !Ilh tlA I° 1 i 1 itt 11 1 i ill fl °�'ii 1 it I i �'it°1 °tit° IlfIt IIi7 l dl if l2'I°It}j l°t i 1 i elf II II t11I k i11 i 1 tii tY I/t t 1 iI {{XI Iti11tt1 t tl 1 i it1I! i 1 11� IY it f °N ° !1 t t t I t 1 i t tl Y °II 1 ti it} 4 �11 fl f t 13 it l i t i t iti t °If°i }tit i !I tiit111 1° 1 t t it t 1 {1 1 ii I 1 i[ 1_ t t 1 IY t i t 11 1 1 t i t! °ttf1!} i. ti t'!ill� Sit 111 it tl iltt f111F� 11 i i Ifl I tliY i 1 f iX I Y h 1 it 111 t Y A Ii i i.tt. 1 i 15 1 I I { 1 1 1 1 It f 1 1 t 1 t tf! {f111°� 112 1t Il o f i 3 t t i i l l it 1 1°I i #;ii,l it pll Yt tt it I 1 (f t ppi il°I°t i I t, F 1t5 t t 11 Iki N fl i 111 It'A lit lfl it - i °�i111 i.ti if i t 1 tl i 1if 1° tt t1 4 111 tY tl t t 1 if I I t 1 t 1 11 tf f i t l !j tl 11 t i Y fl !P f I i it t I iff IINN°t iC 11 t�lY° tiA °tii ti it°t if 11 Fl il�i t!° Y¢IIN 4141)Il fl tii '. IIIi 1°O II li tk lF li tl{il l�f it 1: t Mt i i It ¢�f I[{liil 1. if I i It i 1 r . ti t it it..t; t ttt 1I 1} t'utt 3{° r,.' "1 io It t' ini t i11=ti°°ii ii t u tl ii ii It ii i°ii i° it:i vi i ii ti ti i tr tt St i 11�i tit °ii ii�t i 1 Ii tt ii ii t1 tr t B ELEVATION Imo` i �.»® •^ot ,�w � . __ �'� _ � ti -'� t 1 DFTA%A DETAIL B FIGURE 4—TYPICAL WALL CONNECTION DETAIL -TM I I� � LL a4 � A X-TRA INSULATION PRECAST AMA M SOTEN IRY Yourpermanentbarrier agains t side wall wa ter pone tra tion Clean Crushed Stone Footing Shown Auxiliary Drain Pipe Superior Sealant®Applied in All Joints for Permanent Moisture BarrierWARM . d -y"'O"', F R . } H Y "T-tl "S Warmer in winter,cooler in summer... d reduces your home'seneryy loss ' AV { per�or � Polgisocganurate Insulation Covering Rigid Foam Insulation Sdror ; E th+ 1"Foam Insulation on Concrete Studs i fi 1"Foam Insulation on Bond Beam F SMART owa� Ready to finish... with access built-ink 'a Access Holes for Ease in Wiring and Plumbing Galvanized Steel Stud Facing Ready for Drywall Finishing. CAD Custom-Designed to Virtually Any Home Style ? .e D Laser-leveled to be Plumb,level,Square s Installs on Your Site in Just Hours for Time and Money Savings SUPERIOR Created in a controlled factory environment x to ensure that your now homes foundation willbe D I built to the industryshigheststandards... - € 5,000,PSI Concrete for Superior Strengthollt(; Is _. 10-114"Overall Wall Thickness ; „ �' �' Steel Reinforced Top Bond Beam 1-314"Concrete Face Shell ^ `` Steel Reinforced Concrete Studs y WA Steel Reinforced Footer Beam Concrete Floor Special Note:Items#1,2&12 as well as supepio'r Walkv the%oist/flooring system are provided on site per Superior Walls specifications by builder and contractors as an integral part of the Superior Walls foundation system.. r -TM , ++ ni X—TRA INSULATION Superior Walls foundations feature patented,insulated,precast concrete wall panels that are formed in a factory-controlled setting and delivered to the new home job site,where the panels are lifted into position with a crane and carefully bolted together and sealed. The walls are custom-designed and built to virtually any architectural style,complete with w I n d o w a n d door openings.For moreinformationsee:www.superiorwalls.com. Superior was panels are available in a variety of standard heights and custom lengths to Eml�i RA INSOUmLATION. suit your project.The maximum axial load(uniform house weight]for this product is 7500 � pounds per linear foot.Special point loads up to 50,000 pounds can be accommodated. Provided with 2-112"of Cavity Insulation ;! R-12.5 QUALITY ASSURANCE Each manufacturing plant is regularly inspected bg an independent third-party inspection ® 5000+PSI concrete reinforced ' agency to ensure compliance with the Quality Assurance program. In addition, with rebar and of ro Iene fibers manufacturing and installation personnel are certified by Superior Walls. p yp pg DAMP-PROOFING ® Precast access holes for wiring and plumbing The concrete used in the Superior Walls wall systems provides protection against freezelthaw cycles and water vapor transmission.The urethane sealant used between ® Thermally isolatedrinsulated from exterior panels provides superior protection against water penetration.Therefore,no additional damp-proofing materials are required. • Insulated corners,studs and bond beam VAPOR BARRIER • Monolithically poured=greater strength No Vapor barrier required.Permeance of the Superior Walls panels have been tested in accordance with ASTM E96. • Galvanized steel stud facing FIRE RESISTANCE ♦ May be insulated up to R-50+ Superior Walls products indentified in ICC-ES ESH-1662 do not require the attachment of a 15-minute thermal barrier. ® No additional damp-proofing required Superior Walls products qualify as a two-hour fire separation wall when two layers of 516"Tupe'R'drywall are applied to the studs. ® Precast openings for Windows and doors Superior Walls brand products are manufactured and installed by independently ® Reduces building time owned and operated factories licensed by superior Walls of America,I1d. Check with your local Superior Walls representative for availability ® Readg in virtuallg any weather s� r orior a sSu erior Q_ SU - InSuperior Walls 937 East Earl Road www.superiorwalls.com New Holland, PA 17557 800 452 9255 PN312.64 1 - # # TOWN OF SOUTHOLD BUILDING DEPT. co °ycournv,��'' 631-765-1802 INSPECTION [ F UNDATION 1ST AID [ ] ROUGH PLBG. [ FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS- r, C" � tN N l DATE INSPECTOR R AITAlbert-Righter-Tittmann ARCHITECTS Date: 2 May 2024 4 vt To: Mike Verity Building Department Town Hall Annex Building 54375 Route 25 P.O. Box 1179 Southold NY 11971 From: Jacob Albert A,R&T Architects, Inc. Re: Kathryn&Geddes Parsons house 515 Sterling St. Fishers Island Suffolk Co.Tax Map 1000-10-9-3.1 Enclosed: Plans, elevations, structural plans Structural notes on cupola Revised Permit Drawing Changes A2.0: • Revised foundations for chimney hearths per structural drawings • Revised entry porch pier arrangement to agree with structural drawings A2.1: • Eliminated column in garage in front of garage door A2.2: • Reconfigured Main Bedroom 210 closet layout A2.3: • Added cupola for range hood exhaust A3.0: • Cupola shown in elevations • Revised Main Bedroom west dormer configuration 35 Union Street 4th Flooi Boston,MA U108 617-451.5740. ARIarcliitects.com Esther Hodges-LeClaire From: Helene Woodvine <helene@SiegelStructural.com> Sent: Tuesday, October 3, 2023 4:22 PM To: Esther Hodges-LeClaire Cc: Jacob Albert; 'Z&S Contracting,lnc.' Subject: RE: Parsons Cupola Caution!This message was sent from outside your organization. Allow sender I Block sender Hi Esther, The cupola framing concept,is good and we would expect to have corner posts that tie into attic framing. We will want to use Simpson hardware,—either straps or holdowns to mechanically fasten the posts to framing. 44 posts are adequate and we'd want to use a Simpson LSTA24 strap with 12"onto post and 12"fastened to 2x12 below or a Simpson DTT1Z holdwon can be used to connect post to framing below. The holdown will require a double 2x member below to fasten the holdown. Simpson H2.5 hurrican ties should be used for rafter to wall plate connections. Best, Helene HELENE A.WOODVINE (she her) Associate Principal, VP of Project Management 617.431.3513 From: Esther Hodges-LeClaire<EHLeClaire@artarchitects.com> Sent:Tuesday,October 3,202312:56 PM To: Helene Woodvine<helene@SiegelStructural.com> Cc:Jacob Albert<JAlbert@artarchitects.com>; 'Z&S Contracting,inc.'<zandscontracting@gmaii.com> Subject: RE: Parsons Cupola Hi Helene, Can you confirm receipt of this email?The contractor is eager to proceed with the cupola. -Esther ESTHER HODGES-LECLAIRE,AIA ART I Albert• Righter•Tittmann ARCHITECTS 33 Union Street Boston, MA 02108 1 617.451.5740 Y ARTarchitects.com From: Esther Hodges-LeClaire Sent:Thursday,September 28,2023 1:53 PM To: 'Helene Woodvine'<helene@SiegelStructural.com> Cc:Jacob Albert<JAlbert@arta rchitects.com>; 'Z&S Contracting,Inc.'<zandscontracting@gmail.com> Subject: RE: Parsons Cupola Hi Helene, Checking to make sure you got this email. Have you had a chance to look at the proposed Cupola? Thanks, Esther ESTHER HODGES-LECLAIRE,AIA ART I Albert• Righter•Tittmann ARCHITECTS 33 Union Street Boston; MA 02108 617.451.5740 ARTarchitects.com 9101®® From: Esther Hodges-LeClaire Sent:Wednesday,September 20, 202312:41 PM To:'Helene Woodvine'<helene@SiegelStructural.com> Cc:Jacob Albert<JAlbert artarchitects.com>; 'Z&S Contracting,Inc.' <zandscontracting@gmaii.com> Subject: Parsons Cupola Hi Helene, We've decided to add a cupola to the roof at Parsons. It will sit right where the two rooflines meet.Attached is a sheet of what we're proposing.We'd like to get your input on structural hold downs.We're thinking the corners would be 44 or 6x6 posts that go down through the roof and tie into the attic joists. Could you take a look at this and let us know if you see anything structurally we should be aware of? Thanks, Esther 2 AITARCHITECTS Albert•Righter•Tittmann Date: 2 May 2024 To: Mike Verity Building Department Town Hall Annex Building 54375 Route 25 P.O. Box 1179 Southold NY 11971 From: Jacob Albert A,R&T Architects, Inc. Re: Kathryn& Geddes Parsons house 515 Sterling St. Fishers Island Suffolk Co.Tax Map 1000-10-9-3.1 Enclosed: Plans, elevations, structural plans Structural notes on cupola Revised Permit Drawing Changes A2.0: • Revised foundations for chimney hearths per structural drawings • Revised entry porch pier arrangement to agree with structural drawings A2.1: • Eliminated column in garage in front of garage door A2.2: • Reconfigured Main Bedroom 210 closet layout A2.3: • Added cupola for range hood exhaust A3.0: • Cupola shown in elevations • Revised Main Bedroom west dormer configuration 33 Union Street 4t1i Floor Boston, MA 02108 617.45.1.574Q .ARIarcliitects.com ` Esther Hodges-LeClaire From: Helene Woodvine <helene@SiegelStructural.com> Sent: Tuesday, October 3, 2023 4:22 PM To: Esther Hodges-LeClaire Cc: Jacob Albert; 7&S Contracting,lnc.' Subject: RE: Parsons Cupola __.. r.. . _ . . ........_ Caution!This message was sent from outside your organization. Allow sender Block sender Hi Esther, The cupola framing concept is good and we would expect to have corner posts that tie into attic framing. We will want to use Simpson hardware—either straps or holdowns to mechanically fasten the posts to framing. 4x4 posts are adequate and we'd want to use a Simpson LSTA24 strap with 12" onto post and 12"fastened to 2x12 below or a Simpson DTT1Z holdwon can be used to connect post to framing below. The holdown will require a double 2x member below to fasten the holdown. Simpson H2.5 hurrican ties should be used for rafter to wall plate connections. Best, Helene HELENE A.WOODVINE (she/her) Associate Principal, VP of Project Management 617.431.3513 From: Esther Hodges-LeClaire<EHLeClaire@artarchitects.com> Sent:Tuesday, October 3,2023 12:56 PM To: Helene Woodvine<helene@SiegelStructural.com> Cc:Jacob Albert<JAlbert@artarchitects.com>; 'Z&S Contracting,lnc.'<zandscontracting@gmail.com> Subject: RE: Parsons Cupola Hi Helene, Can you confirm receipt of this email?The contractor is eager to proceed with the cupola. -Esther ESTHER HODGES-LECLAIRE,AIA ART I Albert• Righter•Tittmann ARCHITECTS 33 Union Street Boston, MA 02108 617-451.5740 i a° ARTarchitects.com InCOMM From: Esther Hodges-LeClaire Sent:Thursday,September 28, 2023 1:53 PM To:'Helene Woodvine'<helene@SiegelStructural.com> Cc:Jacob Albert<JAlbert@artarchitects.com>; 'Z&S Contracting,lnc.'<zandscontracting@gmail.com> Subject: RE: Parsons Cupola Hi Helene, Checking to make sure you got this email. Have you had a chance to look at the proposed Cupola? Thanks, - Esther ESTHER HODGES-LECLAIRE,AIA ART I Albert• Righter•Tittmann ARCHITECTS 33 Union Street Boston, MA 02108 617.451.5740 ARTarchitects.com From: Esther Hodges-LeClaire Sent:Wednesday,September 20,2023 12:41 PM To: 'Helene Woodvine'<helene@SiegelStructural.com> Cc:Jacob Albert<JAlbert artarchitects.com>; 'Z&S Contracting,lnc.'<zandscontracting@gmail.com> Subject: Parsons Cupola Hi Helene, We've decided to add a cupola to the roof at Parsons. It will sit right where the two rooflines meet.Attached is a sheet of what we're proposing.We'd like to get your input on structural hold downs.We're thinking the corners would be 4x4 or 6x6 posts that go down through the roof and tie into the attic joists. Could you take a look at this and let us know if you see anything structurally we should be aware of? Thanks, Esther 2 LUL;A I IUN MAP SCALE 1 "=400' NOTES 1.) THIS SURVEY WAS PREPARED FOR THE PARTIES AND PURPOSE INDICATED HEREON. ANY EXTENSION OF THE USE BEYOND THE PURPOSED AGREED TO BETWEEN THE CLIENT AND THE SURVEYOR EXCEEDS THE SCOPE OF THE ENGAGEMENT. 2.) IT IS A VIOLATION OF THE STATE EDUCATION LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED LAND SURVEYOR, TO ALTER AN ITEM IN ANY WAY. .3.) ONLY COPIES OF THIS SURVEY MARKED WITH THE LAND SURVEYOR'S SIGNATURE AND AN ORIGINAL EMBOSSED OR INK SEAL ARE THE PRODUCT OF THE LAND SURVEYOR. 4.) COORDINATE DISTANCES ARE MEASURED FROM U.S. COAST AND GEODETIC SURVEY TRIANGULATION STATION "PROS" 5.) SITE IS IN THE TOWN OF SOUTHOLD, COUNTY OF SUFFOLK TAX MAP 1000, SECTION 010, BLOCK 9, LOT 3.1 6.) TOTAL AREA = 1.90t ACRES. 7.) SITE IS LOCATED IN R-40 ZONE. 8.) BASE FOR LEVELS: NAVD88 9.) PERCENT OF LOT COVERAGE PROPOSED— 5.2% IT is A VIOLATION OF LAW FOR ANY P131SON,UNIM 7HE ACTH UNDER 7NE DIRECTION OF A LICENSED PRMUN 10.) THERE ARE NO DOMESTIC WELLS WITH 150 FEET OF THE PROPOSED STAMP u7ER AN E LANDSCAPE ANY W �'�OR uw SURVEYOR iD aTER AN REM N ANY WAY.IT AN my BENT DEVELOPMENT. Q+�.ARCNIE �A ai THE ALI OR LAN SURVEYOR SHALL STAMP THE DOCU MIT AND MLIOE 1 NOTATION'ALTERED W FOLLOMI BY TIER WNATURE, DATE OF SUCH ALAiNNro SNP ECF7C OESCP SEPTIC SYSTEM DESIGN FOR 5 BEDR0R an�Cs PROVIDE CLEAN—OUT IN BASEMENT— PROVIDE 4" C.I. PIPE TO SEPTIC TANK. PROVIDE 1500 GALLON SEPTIC TANK— INLET INVERT = 20.0 OUTLET INRT= PROVIDE 1 DISTRIBUTION BOX— INLET ELEVA11ONV19 5 19.75 PROVIDE 2 ROWS OF LEACHING GALLEYS (SEE DETAIL)— INLET ELEVATIONS= 19.0 LEACHING REQUIRED-400 SQ. FT.— PROVIDED— 424 SQ. FT. CONNECT ROWS OF CHAMBERS AS SHOWN USE CHAMBERS MANUFACTURED BY DIAMOND PRECAST PRODUCTS EXISTING SEPTIC SYSTEM TO BE LOCATED, PUMPED AND REMOVED. PROVIDE FORM WWM-080 Abandonment of the existing sanitary system must be in] !T. conformance with the Department's requirements. / Submit completed form W1NM-080 as proof vt SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES PERMIT FoR APPROVAL OF CONSTRUCTION FOR SINGLE FAMILY RESIDENCE ONLY MAR 15 ;11199 BUILDING DEP s �„�----- TOWN OF SOUTHOLD 'DATE 1/14/2022 H.S. REF. No. R-21-1737 � APPROVED .0,t FOR MAXIMUM OF 5 BEDROOMS No. Submittal/Revision JAppd By Date EXPIRES THREE YEARS FROM DATE OF APPROVAL 1 ONCRETE CHAMBER DETAIL RHS 08/12/20; }" LEGEND PROPERTY LINE JTLET ABUTTERS LINE EDGE OF PAVEMENT EDGE OF GRAVEL ________________ EXISTING CONTOUR ——— 12 ——— PROPOSED 5 BEDROOM PROPOSED CONTOUR 1s RESIDENCE STONE WALL RETAINING WALL FENCE TREE LINE OVERHEAD WIRES O/W Designed By: Drawn By: Checked By: NOW OR FORMERLY NIF RHS RAC RHS UTILITY POLE f BOUNDARY POINT Issue Date: Project No: Scale: O 06-08-2021 069627 1"=30' Drawing No.: 30 15 0 30 GRAPHIC SCALE IN FEET SHEET 1 OF 1 COARSE SANG-GRAVEL (Slim I z I CONCRETE LEACHING GALLEY 4'-9"x8'-6"x4'-6-1/2" GRGUNuwATER GRILL NOT TO SCALE note COASTAL EROSION HAZARD LINE sS�, NIF o �EXIST ELIZABETH PEISHOFF UMITS..OF FL00D_.ZONE__VE goy. \CONCRETE `r SINGLE FAMILY RESIDENCE FROM FIRM MAP 36103CO019H Ec� b� \ CAP MUNICIPAL WATER SEPTEMBER 25. 2009 - 1 ON SITE SEPTIC SYSTEMEXPANSION AREA 3�50 v \ 9s (2 CHAMBERS) 69 25+ N q12, PROVIDE \ \ \\ EXISTING E 0, � SEA WALL N SILT FENCE 4 — "MAINAI4 00w E ' NDRNGG 3.34' E b 816 \\ CONSTRUCTI Ncj FLAG �\ PROVIDE 4 \ \ LEACHING CHAMBERS ' \ 1` \ � � \ STOCKPILEALE OLD TRAIL (SEE DETAIL) AREA bRADE AREA TO 5X \ PROVIDE , TH \ ^`� \ \ DISTRIBUTION BOX (SEE DETAIL) 01 \ � � PROVIDE 1500 GAL \ 2 \ ° \ SEPTIC TANK (SEE DETAIL).\ �wv \ \ \ \ / - ✓ J / mil SUBJECT TO RIGHTS ACROSS "RESTRICTED LAND" AS NOTED IN LIBER 8367 PAGE 58 PROF 0 ) IN ORDER TO PRESERVE WATER VIEWS OF a•c _ 5 r --�-`J FOR ABUTTING PROPERTY 1 \ \1 �� ,. (FF-: v \ \ / o 25. \ ;\ ° / UNFIT � �. ) \\ � � . I / (FF-' PORTIC w CENTER OF 10' �, / I STERLIONI J WIDE WATER LINE l a ✓ c� RIGHT OF WAY \ �� 1 DISCON LINE NOT IN \ / P°`E >` ., , ,6% THE TO' 9z„ SERVICE PER \ / �. (...r J `�` o� - PROVIDE NEW WE -0- FI WATER WORKS `\ / 36� / COORDINATE W CENTER OF 10' WIDE I ( � it N :� REMOVE EXISTING RESIDENCE. PUMF POLE LINE � c °� RIGHT OF i i SEPTIC SYSTEM-�� L WAY N o W C L. o MATERIAL TO BE S 17'04'00' W c'' N I a� FROM SITE—(PRO1 31.50 PROVIDE' 'RESTRICTED LAND \ \� h 4�\ o �, N �s w TRARUCCTION ER 8367 PAGE 58 Z I I r',� `SB'�?,3� (SEE DETAIL) S =RVE WATER VIEWS CENTER OF \ 11 I 00+ ow 3UTTING PROPERTY \ POLE\ LINE RIGHT OF WAY ` I I c6, `s% s�� MON. , /433 46 \ I \?ems GRAVEL (BURPED) N 1Y-- 00, PARKING �4a I T ;q 00 1w 172.66 \ I i N/F �\ �\ MARTHA A. o J i 3 TORRANCE & LUCIE T. TURRENTI, \ I \ S 64 32,0ow E / 3 ; I 'VACANT LAND" 136.61' 1 • �-� TO BE ACQUIRED BY I N 09'24'46' E I I ^� // J. GEDDES PARSONS LIMITS OF ` 47.79 , h / PROVIDE z 3 DISTURBANCE STAGING `V /t CONCRETE o COD to 28.000t S.F. AREA \ `' k/ f WASHOUT PIT c (SEE DETAIL) PARKING- AREA N 6500'03" W S 25*01'150 W 1,384f SO. FT. 45.74 y 23.75' SHED 6, 0 "DRY" BUILDING o\ l v N 1510.69 / Az�� � W 201.89 S 25'01'15" W 17.00' / _F PIPE 160.56, k0 p / PRON PIPE g 841915' W i (FOUND) x N/F ROBERTA C. ELWELL � SINGLE FAMILY RESIDENCE �i MUNICIPAL WATER / ,OCKS AND CATCH ON SITE SEPTIC SYSTEM , ISIN GRATE TO GRADE / A IJEENAH R-2525—F) OR EQUAL / % <,_.1NLEAZS 5 TOOV� V� rw rlot _ WEST Ci HARBOR STTE aerwt TO BE PLANT[ AS NONR RL SEA e.y HOC7ATID o.vrLn AREASIt N L, PREPARED FOR: IL'lILl11 1. J. GEDDES -ARSONS ^�• •s•'_a 'oy / ' ca. 4 5'5 STERUhG ST4E ET / _ \a `.\ ✓!/\ / FISHERS IS.AVD, M! / !'''-=!• P °�%,•. B i LOCATION MAP SCALE 1`-400' l /� fMAP _ 09Y OCll I.)PROPOSED LOT uNE C„ANGE PREPARED FOR-ARR o 9 DARSD•rS S L-SC pRoyoc n AIC3. T ^DA DATE. 15',AND. NE.fpR[, SCALE CR, A; S-A Ar:G: (S RUN OFF(I) vOgrCR,CT.,OA IL. NOLEuOFV 15.1991; SCALE I'+7J'; S••iCT I Or, `.f'f��� j,)'$•iC?LAN RRERARIJ fO�. GEDDES iARSONS 515$:ED-C STREET ri$HERS SCALE:AAV J.vt,' 1'- . / •i1�OC ASSOCIAT[S 70^. DA'E 5-ae-jC7l. By C•.(u:dl w A_/ $ARGOT REMOVE Or K PRONOC TRLA I DRAW / AAD CO WLCT TO 'O)�t•'• ,v) / ROW OR,WELL HOTIER •JD�• ;% / 1) pus'JITNEY RAS PREPARED rw , ARPiS ANC R ;PCSE N. C.,TED / "EREON ANY[%TEES DN Of I�rt u5C JC•C1�T••E PJPPCSED AGREED-0 DETKE-;r.E CIE, T.•E SURA fOP I- COS TwL SCOPE Jr [ `'t,���, +'rf!,''•SA—,AND ROIJK 1%_AG1111i v 4,, KPIT10N Or WALK PROVIDE T1mICH DRAM 2.)IT IS A COLATIJN Of TIE STATE LDJCAIGN LAA C09 A%V&(ITSOv. _E AND Ca�77 uM1l Cs$ACT.:UNDER .E D'Rt^.Fy.pT.uCE a5E0 LA•.c UR•rt..�.ro ALTER Ali It.1%ANY A.1 3.)ONLT COILS Of i•I^,/. W -.�.I// / _� PC-A•,:N.nA:- J NI•, ELAND OBS tI AND AI 0R-DVL C.Sa-S!D D4 t SEAL ARF I-E-RGJ.0 T Cr fr.E LAND SJRKrJt. J. CE$ARE a EJ EaOV US COAST AND[:G:EYC NCR.--,El SEPl:E URW•TRIANCJLIv S'Ai:D• ­OS' •CI •�.��/I'`r: •7:A-,, wvo�r.'�j Yam'WY rv,m..a i' 0•'s rfo-R Tu.L•Aa!OX. F.i q•'w;r"1�^M�'m.o r m..M ,•/ -T'I I �. N/F SCCDO•:010.BLCC•.9,l01 3 w.Re 7��e rw�iavvo THOLLAS IJ. SHIELD 1` SINGLE FAVI)'aES%DE7fCF' 6 i TOTAL AREA !90: ACVLS / ), ` 4!JtIICIPA+ WATER 7.)SITE IS LOCATED R P-AD 73Ir �/ ON WE SEPTIC SYSIEM B)OASC FOP LEVELS NAN938 � _, I R_y LGN a• '� :ER.•:G:TPLn '� ng:rrTNro B- _� :7— iJ IH I381:9: ,�- - 172.65 i�i �W � S 0!'Ot•A T'w A, 1 \\ 4 �,\ ••° )�,,.r. Aa-A I PAPCEL ACQUIRED BY W J. GEDDES PARSO\S I USER D0001J1)1 PAGE 651 ^SY,+ II-19-1011 e- LEGEND - I PRDP[etY LANE %� I APUitCRS L:NC —— LDOC Or PAVrUENT J LOOL OF GRAVE', -:--•`N"---------- —•-- _'n m:�M: On TDlr .LTA•.ND HALL f0•G NOw OR rORULR.r h� I UPLTr"'I R. rteU•o4 :ele+ • I F i) •- , � �} Il.�f a•.:,Lvrnrs ce�r� :'aT , �-;21 .— - 4_ o0B:D OF 1 ( US 1 EIS jQ s x TOWI! OF SOUTHOLDO oaAKCCALNFEET ATE V' - -- AS-BUILT I I'i C.AywP tll D-A e�BI G^•:•AO tll 1 _•'L%/7�Y"_.y]^��_t-�• _�bI(�i��. .�_' ' ' �� � I � �� Iu:.DaT. I P:aecl Ia Sfa,. / i- �, I I I � �� {i i i I loa•:Jx! eszxr I .:j } k SHEET 1 oil l SOI/lyo6 # # TOWN OF SOUTHOLD BUIL�1 G DEPT. 765-1802 ANSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY -[ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT-CONSTRUCTION [ ]' FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: S nif n cr\ e �rnAs Ar I C �s 7/2 DATE INSPECTOR aoF souryO# Q TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 �D NSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIR ESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ LECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: PJtA Doe -5-11 li��7 cQ�V, @�Vrl,-v c M DATE INSPECTOR (IVL SOUTy 01(O�J o TOWN OF SOUTHOLD BUILDING DEFT. courm, 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY - [ ] FIRE SAFETY INSPECTION. [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: a4 DATE INSPECTOR ,., "`'�- ..r �. Aso �y ,. � 1 � �� i AUG 2 6 2025 F Building Department Town of Southold stratus io - r 5 41.4 T__ a A U G 2 6 2025 Building Department Town of Southold T P'n y � i • * sue•. i� s_ DraWn C n g opy'ght®2015 DRILL WEST HOLE COASTAL EROSION ly�s \ 1 33 Wilbur Cross Way,Mansfield, 06268 HAZARD LINE \s / 101 East River Drive,1st Floor HARBOR I / East Hartford,CT 06108 S. 860-885-1055 1 www.chacompanies.com / / • EXISTING G- ��t7 N F �. CONCRETE �\ ELIZABETH PEISHOFF LIMITS OF FLOOD ZONE VE �h O CAP N/F SINGLE FAMILY RESIDENCE SEPTEMBER 25 2009 SITE,FROM FIRM MAP 3610300019H y� cos tic S9j,CHARLES W. GREENLEAF MUNICIPAL WATER 4 V � "VACANT LAND" ON SITE SEPTIC SYSTEM r M \ g9 34 1�� , \ \ \ , r N Z �j 0 Jt- All• \ EXISTING ��`��� 1 \ SEA WALL yG / N 6734'00" E 46•p7 ` , S 65'41'00" E z . E 35.00' m 3.34' J STONE WALL N 81'06 30 SURVEY MAP Go 64.80 a� ` ` \ Go rye 2 PREPARED FOR: Q Z — J. GEDDES PARSONS 515 STERLING STREET FISHERS ISLAND, NY LOCATION MAP SCALE 1 =400 IAAP REFERENCES �03 1.) PROPOSED LOT LINE CHANGE PREPARED FOR HARRIS B. PARSONS & ELSIE ^ ,A� W. PARSONS; FISHERS ISLAND, NEW YORK; CHANDLER, PALMER & KING; NORWICH, CT.; DATE: NOVEMBER 15, 1991; SCALE: 1"=20'; SHEET 1 OF 1 N/F \\ \ SUBJECT TO RIGHTS ACROSS "RESTRICTED LAND" MONTAUK LLC AS NOTED IN LIBER 8367 PAGE 58 \ 2.) "SITE PLAN PREPARED FOR: J. GEDDES PARSONS 515 STERLING STREET SINGLE FAMILY \� \ IN ORDER TO PRESERVE WATER VIEWS FISHERS ISLAND, NY;" SCALE: 1"=30'; DATE: 06-08-2021; BY CL.OUGH HARBOR RESIDENCE �` \ FOR ABUTTING PROPERTY ASSOCIATES MUNICIPAL WATER F F��ST�Nc ON SITE SEPTIC SYSTEM \\\ <o o'�rio �\ 70 , ?r-b NOTES \ 20`2�22 1.) THIS SURVEY WAS PREPARED FOR THE PARTIES AND PURPOSE INDICATED O PNQ �n� \ / HEREON. ANY EXTENSION OF THE USE BEYOND THE PURPOSED AGREED TO �G G, BETWEEN THE CLIENT AND THE SURVEYOR EXCEEDS THE SCOPE OF THE �P ENGAGEMENT. CENTER OF 10' WIDE WATER LINE � RIGHT OF WAY \ / 2.) IT IS A VIOLATION OF THE STATE EDUCATION LAW FOR ANY PERSON, r- EXISTING i'� h LINE NOT IN �6' UNLESS ACTING UNDER THE DIRECTION OF A LICENSED LAND SURVEYOR, TO n ,�_��.p>F j- 0 RESIDENCE �OrO SERVICE PER POLE ` ALTER AN ITEM IN ANY WAY. �'L 051075 FI WATER WORKS DRILL HOLE 3.) ONLY COPIES OF THIS SURVEY MARKED WITH THE LAND SURVEYORS LAND \ SIGNATURE AND AN ORIGINAL EMBOSSED OR INK SEAL ARE THE PRODUCT OF V THE LAND SURVEYOR. ✓� \ 3 3 N/F 4.) COORDINATE DISTANCES ARE MEASURED FROM U.S. COAST AND GEODETIC rc C A VIOLATION of uw TIO ANY PERSON UNLESS THUSSIO ARE "PROS" ACTING UNDER RTHECH DIRECTION LAN OF A LICENSED PROFESSIONAL LAM THOMAS J. SHILLO SURVEY TRIANGULATION STATION PROS ENaM A ARCHITECT.ITEM LANDSCAPE W .IF AN IT M LAw M SURVEYOR TD ALTER AN ITEM N ANY WAY.i AN ITEM BEARING THE b o` SINGLE FAMILY RESIDENCE STAMP OF A LICENSED PROFESSIONAL IS ALTERED,THE AL70 MG ^ 10 ENGINEER.ARCIMCT,LANDSCAPE ARCMTECT OR LAND o MUNICIPAL WATER 5•) SITE IS IN THE TOWN OF SOUTHOLD, COUNTY OF SUFFOLK TAX MAP 1000, AIM SHALL STAMP THE DOCUMENT AND INCLUDE THE �' nE :CTTON 010, BLOCK 9, LOT 3.1 DATE OF NOTATION �Slp'1 ALTERATIONERED Wr ,AND AAND SPECIFIC DESCRIPTION CENTER CENTER OF MON �. 0) ON SITE SEPTIC SYSTEM OF THE ALTERATION. / 10' WIDE 3 _ 6.) TOTAL AREA = 1.90t ACRES. POLE LINE \ RIGHT OF \ / 7.) SITE IS LOCATED IN R-40 ZONE. EXISTING Op WAY GARAGE �. / 8.) BASE S FOR LEVELS: NAVD88 / PORTION OF � I N \ STERLING STREET / SUBJECT TO RI NOTED ACROSS NSLIBER"RESTRICTED PAGE 58 I DISCONTINUED BY CENTER OF \ THE TOWN JULY 9, 1963 IN ORDER TO PRESERVE WATER VIEWS POLE LINE \ ` \ POLE / 188.9g, FOR ABUTTING PROPERTY RIGHT OF WAY \ EXISTING MON. #433 GRAVEL N ZZ 5j„ W PARKING BURIED) N 1582.94 \ Y W 172.66 S 05'01'41" W 11.31' \\ 3 PARCEL ACQUIRED BY I J. GEDDES PARSONS LaiI LIBER D00013131 PAGE 651 ,2 11-29-2021 S 25'01'15" W ^� .0r 21.s2' LEGEND PROPERTY LINE N/F I ABUTTERS LINE —— JAMES & JEANNIE BALLENTINE 3 I EDGE OF PAVEMENT SINNGLE FAMILY RESIDENCE EDGE OF GRAVEL ------------------- No. Submittal/Revision aPp'd By Date 3: MUNICIPAL WATER z 3 \ STONE WALL ON SITE SEPTIC SYSTEM o ao in \ RETAINING WALL .. � n .� � 0 Issued For Review XXX XXX 00/00/2018 1 �� FENCE �— x x m t CC11 .0. �`` NOW OR FORMERLY N/F U) $ ? I UTILITY POLE —e— ' y I BOUNDARY POINT O o SHEID 0 U_ "DRY" BUILDIN(G \ 3 N �V N 1510.69 % W 201.89 Z S 2501'150 W 17.00' _ 20 10 0 20 w IRON / GRAPHIC SCALE IN FEET N PIPE CD 160.569 FOUNDATION LOCATION w IRON S 84'3r5" W F_ PIPE yf PLAN (FOUND) r I Designed B Drawn B Checked B N/F I 9 Y Y Y w ROBERTA C. ELWELL --- NBC CB � w SINGLE FAMILY RESIDENCE Issue Date: Project No: Scale: U) MUNICIPAL WATER / 11-3-2022 069627 1"=20' o ON SITE SEPTIC SYSTEM / of \ Drawing No.: L� SHEET 1 iu E E A, R&T Architects, Inc. 33 Union Street, 4``'floor Boston MA 02108 UILDING DEPT. (617) 451-5740 -TOVq-OF SOU-V,-ju0j 22 April 2022 Amanda Nunemaker Building Department Town Hall Annex Building 54375 Route 25 .P.O. Box 1179 Southold NY 11971 Re: Kathryn & Geddes Parsons house 515 Sterling St . Fishers Island Suffolk .Co. Tax Map 1000-1079-3. 1 Dear Ms. Nunemaker: Thanks for reviewing the Building Permit application by Z&S Contracting for the Parsons house at Fishers Island. To ans er your questions: . Z&S will provide a disconnect letter from FI Utilities stating electric has been disconnected to dwelling. 2 . There is no natural gas on site. 3 . See enclosed manufacturer' s specs for the Superior Wall foundation. 4 . We have noted on the Window Schedule which windows meet egress requirements according to NYS code. See enclosed page A5 . 1. The Window Schedule references Plan pages A2 . 1 and A2 . 2 . 5. The emergency egress from the basement is a pair of doors, with each door 3' -0" wide x 6' -8" high. See enclosed page A5. 1, where Door #001 is described on the Door Schedule, and basement plan on page A2 . 0 . These doors take you outside, under the deck. From this space under the deck you then exit through a pair of doors in the under-deck screening. These doors are each 3' -0" wide x 7' -5" high. See enclosed elevation page A3. 0 . Very truly yours, Jacob D. Albert I Amanda Nunemaker Southold Building Department Dear Amanda,.my name is James Cushing,and I am the superintendent with the Fishers Island Electric company. I am writing to inform the Southold building department that the overhead 120/240-volt service @ 515 Sterling St has been disconnected and removed from the dwelling on 4/19/22 Best regards, James Cushing JcushingCcDfiuc.net 860-333-4799 I 3 1 t I NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION Division W Environmental Permits,Region 1 SUNY A' Stony Brook,50 Orcto Runt,Stony Brook:P!Y 11790 P.(631)144•0355 I F:(031)a,14.0360 LETTER OF NO-JURISDICTION October S, 2021 J. Geddes Parsons Re: Application ID 1-4738-00260/00004. CIO Parsons Capital Management 515.Sterling Street 10 Wey boss et.Street, Suite 1000 Fishers Island Providence, RI 02903 SUM # 1000-1.0-9-3.1 ARNO-DEP Dear Applicant: Based on the information your agent submitted and additional New York State Department of Environmental Conservation (DEC) information,;DEC has made the following determination. The portion of the referenced property landward of the existing functional concrete seawall more than 100 feet in length and originally constructed prior to 8/20/1977, as evidenced on a.property survey of a portion, of the property dated December 30:, 1975 and a 1962 aerial. photograph, is beyond the jurisdiction of Article 25 Tidal Wetlands. Therefore, in accordance with the current tidal Wetlands Land Use.Regulations (6 NYCRR Part 661), no permit is required for work. occurring at the property landward. of the jurisdictional boundary described above. Please be advised however, that no construction, sedimentation, discharge, or disturbance of any kind -may take place seaward of the jurisdictional boundary without a permit. It is your responsibility to ensure that all necessary precautions are taken to prevent any sedimentation or other alteration,or disturbance to the ground surface or vegetation within DEC's jurisdiction which may result from your project. Such precautions may include, maintaining an adequate, work. area .(i.e. a 15' to 20' wide construction area) or erecting a temporary fence, barrier, or hay bale berm. Please be further advised that this letter does not relieve you of the responsibility of obtaining any necessary permits or approvals from local municipalities or other agencies. Very trul yours, Susan V. Ackerman Regional Permit Administrator SVAfmrp CC: .JMO Environmental Consulting BM HP File �,g r+swvoRK Department of Envirombental '��- r Conservation '�'.�� e ,ii� x1 7 `z.rfi.Y75tn .Ys '1".xz .a '-C`e'slvtrc:FAskit++ ��ax' ,'.,a. ,�22.s5e2�rrq+ tn4dTnw9`' f1i.'±�. .�+^"` y". , i BOARD OF SOUTHOLD TOWN TRUSTEES a a SOUTHOLD, NEW YORK P PERMIT NO. 10005&10005C DATE: OCTOBER 20,2021 ISSUED TO: J.GEDDES PARSONS PROPERTY ADDRESS: 515 STERLING STREET,FISHERS ISLAND X 0 a ` SCTM#1000-10-9-3.1 AUTHORIZATION r Pursuant to the provisions of Chapter 275 and/or Chapter I I I of the Town Code of the Town of Southold and in accordance with the Resolution of the Board of Trustees adopted at the meeting held on gi October 20,2021 and.in consideration of application fee in the sum of$500.00 paid by J.Geddes Parsons and f subject to the Terms and Conditions as stated in the Resolution,the Southold Town Board of Trustees authorizes and permits the following: ,4; , r" Wetland Permit to demolish existing single-family dwelling, pump out the existing sanitary system and remove all material from site; construct a new single-family dwelling with attached garage,three(3) ` dryweiis for roof runoff, decks and steps for a footprint of 4,306sq.ft.; install new water service;install a new I/A OWTS sanitary system and regrade;to repair the existing 132'seawall;to construct a new 132' ; f block retaining wall landward of existing seawall; to backfill the structure with approximately 95 cubic t ak yards of clean fill to match existing elevation;and to mulch and seed the 2,630sq.ft.disturbed area; F �' establish and perpetually maintain anon-turf buffer between bulkhead and retaining wall and install and perpetually maintain a 10'wide non turf buffer landward of the retaining wall;and as depicted on the site Y plan prepared.by CME Associates Engineering; Land Surveying&Architecture, PLLC,received on .. t x91 October 19,2021,and stamped approved on October 20,2021. t r IN WITNESS WHEREOF,the said.Board of Trustees hereby causes its Corporate Seal to be affixed, and these presents to be subscribed by a majority of the said Board as of the 20th day of October,2021. z. co g4Jfi 2b y, 'Ey � �rn YVfy�n"3.z°�a`Cu%iv�S�,kYex°4k4EEir9s3£'��`. 'a4kui'4ri.1'sofA7�sYP4m'6 PtSLlaTYtkzUv�k�.Et�ee'in7,'�P�NTi'�''�ttYA`*ex.Ya`�dl�eR`E4}.t3'a'14Y+•`.03s'f.�4tifflaWtY'ei�i^aWa}4�'YlARz'Stf9`ls'.(bY° Y}{53�5'EftdX2fLL Ja(r•13n�7�G,,*��.+�l } . � f �..al.. P"�.• '�. �� + `��sq\ alb.%y� t�..�, ts.`rstFi�F Glenn Goldsmith,President � � Town Hall Annex ` \A.NicholAs Krupski,Vice President 54375 Route 25P.O. .Box 11.79 John M.Bxedemeyer III Southold,New York 11971 Michael J.Domino coqTelephone(631) 765-1892 Greg Williams � Y - Fax(63.1.) 765-6641 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD COASTAL EROSION MANAGEMENT PERMIT COASTAL EROSION PERMIT#10005C ApplicantlAgent: J.M.O. Environmental Consulting Permittee: J. Ged.des Parsons SCTM#: 1000-10-9-3.1 Project Location: 516 Sterling Street, Fishers Island Date of Resolution/Issuance: October 20, 2021 Date of Expiration: October 20, 2023 Reviewed by: Board of Trustees DESCRIPTION OF ACTIVITY: Demolish existing single-family dwelling; pump out the existing sanitary system and remove all material from site; construct a new single-family dwelling with attached garage, three(3) drywells for roof runoff, decks and steps for a footprint of 4,306sq.ft.; install new water service; install a new I/A OWTS sanitary system and regrade; to repair the existing 132' seawall; to construct a new 132'block retaining wall landward of existing seawall; to backfill the structure with approximately 95 cubic yards of clean fill to match existing elevation; and to mulch and seed the 2,630sq.ft. disturbed area; establish and perpetually maintain a non-turf buffer between bulkhead and retaining wall and install and perpetually maintain a 10'wide non turf buffer landward of the retaining wall; and as depicted on the site plan prepared by CME Associates Engineering, Land Surveying & Architecture, PLLC, received on October 19, 2021, and stamped approved on October 20, 2021. INSPECTIONS: Final Inspection SPECIAL CONDITIONS: None In accordance with Chapter 111-15 Erosion Protection Structures: xx A maintenance agreement is attached hereto and is a necessary special condition of this permit. B A' %% y: S e Z- I . Glenn Goldsmith, President Board of Trustees Glenn.Goldsmith, President so Town Hall Annex A. Nicholas$rupski,Vice President �� � �� 54375 Route 25 P:O. Box 1.179 John M.Bredemey=er III Southold,New York 11971 Michael J. Domino Telephone(631) 765-1892 Greg Williams .tl7 Fax(631) 765-.6641 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD October 21, 2021 Glenn E. Just J.M.O. Environmental Consulting Services P.O. Box 447 Quogue, NY 11959-0447 RE: J. .GEDDES PARSONS 515_STERLING STREET, FISHERS ISLAND SCTM#1000-10-9-3.1 Dear Mr. Just: The following action was taken by the Southold Town Board of Trustees at their Regular Meeting held on Wednesday, October 20, 2021: WHEREAS, J.M.O. Environmental Consulting, on behalf of J. GEDDES PARSONS applied to the Southold Town Trustees for a Permit under the provisions of Chapter 275 of the Southold Town Code, the Wetland Ordinance'of the Town of Southold, and Chapter 111 of the Southold Town. Code, Coastal Erosion Hazard Areas, application dated August 23, 2021, and, WHEREAS, said application was referred to the Southold Town Conservation Advisory Council and to the Local Waterfront Revitalization Program Coordinator for their findings and recommendations, and, WHEREAS, the LWRP Coordinator issued a recommendation that the seawall work is recommended as Consistent with the Local Waterfront Revitalization Program policy standards, and WHEREAS, the LWRP Coordinator recommended that the action be found Inconsistent with the LWRP, and, WHEREAS, the Board of Trustees has furthered policy of the Local Waterfront Revitalization Program to the greatest extent possible through the imposition of the following 'Best Management Practice requirements: upon Trustee review - the plan and project description submitted satisfy the concerns of the LWRP; and 2 WHEREAS, .a Public Hearing was held by the Town Trustees with respect to said application on October 20, 2021, at which time all interested persons were given an opportunity to be heard, and, WHEREAS, the structure complies with the standards set forth in Chapter 275 and Chapter 111 of the Southold Town Code, WHEREAS, the Board has determined that the project as proposed will not affect the health, safety and general welfare of the people of the town, NOW THEREFORE BE IT, RESOLVED, that for the mitigating factors and based upon the Best Management Practice requirement imposed above., the Board of Trustees deems the action to be Consistent with the Local Waterfront Revitalization Program pursuant to Chapter 268 of the Southold Town Code, and, RESOLVED, that the Board of Trustees APPROVES the application of J. GEDDES PARSONS to demolish existing single-family dwelling; pump out the existing sanitary system and remove all material from site; construct a new single-family dwelling with attached garage,three (3) drywells for roof runoff, decks and steps for a footprint of 4;306sq.ft.; install new water service; install a new 1/A OWTS sanitary system and regrade; to repair the existing 132' seawall; to construct a new 132' block retaining wall landward of existing seawall; to.backfill the:structure with approximately 95 cubic yards of clean fill to match existing elevation; and to mulch and seed the 2,630sq.ft. disturbed area; establish and perpetually maintain a non-turf buffer between bulkhead and retaining wall and install and perpetually maintain a 10' wide non turf buffer landward of , the retaining wall; and as depicted on the site plan prepared by CME Associates Engineering, Land. Surveying & Architecture, PLLC, received on October 19, 2021, and stamped approved on October 20, 2021. Permit to construct and complete project will expire two years from the date the permit is signed. Fees must be paid, if applicable, and permit issued within six months of the date of this notification. Inspections are required at a fee of$50.00 per inspection. (See attached schedule.) Fees: $ 5.0.00 Very truly yours, Glenn Goldsmith President, Board of Trustees 4 Generated by REScheck-Web Software Compliance Certificate Project Parsons - Sterling Street House Energy Code: 2018 IECC Location: Southold, New York Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 4,592 ft2 Glazing Area 3.6% Climate Zone: 4 (5572 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: Sterling Street Jacob Albert Fishers Island,New York 06390 Albert, Righter&Tittmann Architects, Inc 262 Washington St Floor 2 Boston, MA 02108 617-515-4965 jalbeit@artarchitects.com . . off Compliance: 15.4%Better Than Code Maximum UA: 1082 Your UA: 915 Maximum SHGC: 0.40 Your SHGC: 0.06 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Envelope Assemblies Gross Area Cavity Cont. Prop. Req. Prop. Req. Perimeter Ceiling: Flat Ceiling or Scissor Truss 3,783 56.0 0.0 0.024 0.026 91 98 Wall:Wood Frame, 16"o.c. 5,154 38.5 0.0 0.044 0.060 174 237 Door 1: Solid Door(under 50%glazing) 222 0.200 0.320 44 71 Door:Glass Door(over 50%glazing) 101 0.310 0.320 31 32 SHGC: 0.10 Window:Wood Frame 876 0.310 0.320 272 280 SHGC: 0.05 Wall 1: Insulated Concrete Forms 878 15.0 0.068 0.098 56 81 Door 2: Solid Door(under 50%glazing) 40 0.100 0.320 4 13 Window 1:Wood Frame 10 0.310 0.320 3 3 SHGC:0.05 Floor:All-Wood Joist/Truss 3,443 21.0 0.0 0.044 0.047 151 162 Floor 1:All-Wood Joist/Truss 343 56.0 0.0 0.019 0.047 7 16 Project Title: Parsons-Sterling Street House Report date: 12/23/21 Data filename: � Page 1 of10 4 Gross Area Cavity Cont. Prop. Req. Prop. Req. Perimeter Basement: Insulated Concrete Forms Wall height:8.5' 1,283 15.0 0.054 0.059 69 76 Depth below grade: 7.0' Insulation depth: 8.5' Crawl: Insulated Concrete Forms Wall height: 5.5' 428 15.0 0.065 0.065 13 13 Depth below grade:4.9' Insulation depth: 5.5' Compliance Statement: The proposed building design described here is consistent with the building plans,specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name-Title Signature Date Project Title: Parsons - Sterling Street House Report date: 12/23/21 Data filename: Page 2 of10 REScheck Software Version : REScheck-Web Inspection Checklist Energy Code: 2018 IECC Requirements: 100.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified FieldEVerified Com lies Comments/Assumptions . # �Pre,ln�pection/PlanReview .,Valua Value p 103.1, ;Construction drawings and ❑Complies `Requirement will be met. 103.2 ;documentation demonstrate ❑Does Not [PRl]i (energy code compliance for the ❑Not Observable t building envelope.Thermal ` ,envelope represented on —]Not Applicable construction documents. „ 103.1, ;Construction drawings and ❑Complies ;Requirement will be met. 103.21 :documentation demonstrate ( t ❑Does Not 403.7 ;energy code compliance for ❑Not Observable [PR3]1 Jighting and mechanical systems r ❑Not Applicable :Systems serving multiple ;dwelling units must demonstrate ,compliance with the IECC t Commercial Provisions. 3g 3021, Heating and cooling equipment is Heating: Heating: ❑Complies :Requirement will be met. 4037 sized per ACCA Manual S based Btu/hr Btu/hr '!❑Does Not [PR2]z on loads calculated per ACCA Cooling: Cooling: ❑Not Observable ; Manual J or other methods Btu/hr Btu/hr ❑Not Applicable ;l approved by the code official. � 3 Additional Comments/Assumptions: 1 High Impact(Tier 1) J)Pp'l Medium Impact(Tier 2) 3::. Low Impact(Tier 3) Project Title: Parsons- Sterling Street House Report date: 12/23/21 Data filename: Page 3 of10 Sectlon rv, Plans Uerf�ed F�eIcI Ver�f�ed # � oudat[on Inspection mplies� Comt�ents/Assumptions V slue Value Co r 402.1.1 ;Conditioned basement wall R- R- ;❑Complies !See the Envelope Assemblies [F04]1 ;insulation R-value.Where interior R_ R_ ❑Does Not ;table for values. t ; ;insulation is used,verification ❑Not Observable may need to occur during ❑Not Applicable Ilnsulation Inspection. Not required in warm-humid locations ; I in Climate Zone 3. I 303.2 ;Conditioned basement wall ; ❑Complies ;Requirement will be met. [F05]1 ;insulation installed per ( t ❑Does Not } ;manufacturer's instructions. f ?❑Not Observable ❑Not Applicable 402.2.9 ;Conditioned basement wall ft ft ❑Complies ;See the Envelope Assemblies [F06]1 i insulation depth of burial or ❑Does Not ;table for values. ;distance from top of wall. ;❑Not Observable ❑Not Applicable s 402.2.11 Unvented crawl space wall R- R- ❑Complies ;See the Envelope Assemblies [F07]1 !insulation R-value. R- R- ❑Does Not ;table for values. ; ❑Not Observable 3 ❑Not Applicable 303.2 ;Unvented crawl space wall I r °❑Complies ;Requirement will be met. [FOB]' I insulation installed per ❑Does Not =manufacturer's instructions. �94, * t ''�. �� - ',K❑Not Observable i ❑Not Applicable 402.2.11 ;Unvented crawl space continuous w ' ❑Complies 'Requirement will be met. €' ; [F09]1 (vapor retarder installed over { ❑Does Not ;exposed earth,joints overlapped z 1.❑Not Observable IM I by 6 in.and sealed, extending at ;` E s.. z❑Not Applicable }least 6 in. up and attached to the ;wall. 402.2.11 ;Unvented crawl space wall in. i in. ❑Complies ;See the Envelope Assemblies [FO10]1 ±insulation depth of burial or I ❑Does Not ktable for values. !distance from top of wall. ;❑Not Observable + ❑Not Applicable ; 4 , 303 2 1 IA protective covering is installed �i Complies ;Requirement will be met. [P0111z Ito protect exposed exterior '❑Does Not insulation and extends a ❑Not Observable minimum of 6 in. below grade. It .. fi❑Not Applicable 4039 " ;Snow-and ice-melting system F❑Complies ;Requirement will be met. 1012]� (controls installed. Does Not I I jts ,s� ? r* ❑NOt Observable i `❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2; Medium Impact(Tier 2) 3` Low Impact(Tier 3) Project Title: Parsons- Sterling Street House Report date: 12/23/21 Data filename: Page 4 of10 Section Plans Verified F,�eld�Verif�e'd F Rough In Inspection omptres� Go Value 4 V flue G mments/Assumptions ' 402.1.1, ;Door U-factor. U- I U- ❑Complies ;See the Envelope Assemblies 402.3.4 F ❑Does Not !table for values. [FR1]1 ;❑Not Observable : E ;❑Not Applicable E 402.1.1, i Glazing U-factor(area-weighted U- U- ❑Complies ;See the Envelope Assemblies 402.3.1, average). _ ❑Does Not ;table for values. 402.3.3, []Not Observable 402.5 ❑Not Applicable E [FR2]1 l , 303.1.3 ;U-factors of fenestration products ❑Complies `Requirement will be met. [FR4]1 ;are determined in accordance v e, =❑Does Not ;with.the NFRC test procedure or i❑Not Observable taken from the default table. ❑Not Applicable 402.4.1.1 ;Air barrier and thermal barrier ' f� ❑Complies ,Requirement will be met. [FR23]1 :installed per manufacturer's r ❑Does Not ; instructions. 4❑Not Observable ❑Not Applicable ��._._ _""_"""___ .._'_ .___ _. .'....'. ,..... _:_ ❑Com lies ____... ;Requirement will be met. 402.4.3 ;Fenestration that is not site built p q [FR20]1 !is listed and labeled as meeting I ❑Does Not 3 ;AAMA/WDMA/CSA 101/I.S.2/A440 ❑Not Observable ` ,or has infiltration rates per NFRC ❑Not Applicable '400 that do not exceed code limits. 4024 5 IC-rated recessed lighting fixtures ❑Complies Requirement will be met. [FRl6]� sealed at housing/interior finish s❑Does Not and labeled to indicate :52.0 cfm I <-]Not Observable leakage at 75 Pa. A ❑Not Applicable 403.3 1 Supply and return ducts in attics ❑Complies ;Exception: Ducts located [FR12]1 I insulated >= R-8 where duct is ODoes Not !completely inside the ;building envelope. >= 3 inches in diameter and > } � ❑Not Observable ; R-6 where< 3 inches. Supply and , ❑Not Applicable I return ducts in other portions of I jthe building insulated >= R-6 for diameter>= 3 inches and R-4.2 3 �� !for< 3 inches in diameter. I 403.3.2 Ducts,air handlers and filter t` ❑Complies $Requirement will be met. [FR13]1 !boxes are sealed with I ❑Does Not ;points/seams compliant with ?❑Not Observable 'International Mechanical Code or 1 ❑Not Applicable I International Residential Code, as applicable. 40.3 5 omplies Building cavities are not used as ❑C !Requirement will be met. [FR15]3 ducts or plenums. ❑Does Not ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) Z=' Medium Impact(Tier 2) 3' Low Impact(Tier 3) Project Title: Parsons - Sterling Street House Report date: 12/23/21 Data filename: Page 5 of10 Sectron " 01ans Verified d IField Nerilfled Framing/Rough In Inspection Complies Oomrments/Assum,ptions` & R'eq ID..•. Value Value 403.3.71, ;Ducts declared to be within the 4 s❑Complies ;Requirement will be met. [FR28]3 'conditioned space are either 1) I ❑Does Not completely within the continuous � � _ r❑Not Observable air barrier and within the building " thermal envelope,2) buried ❑Not Applicable ,!within ceiling insulation in i accordance with Section I u R403.3.6 and the air handler is i 'located completely within the ; continuous air barrier and within the building thermal envelope i m ;and the duct leakage is <= 1.5 ' cfm/100 square feet of conditioned floor area served by F ?the duct system, or 3)the ceiling insulation R-value installed ' 3 ;against and above the insulated duct>=to the proposed ceiling insulation R-value, less the R- i value of the insulation on the 403.4 HVAC piping conveying fluids R- R ElComplies !Requirement will be met. [FR17]2 above 105 QF or chilled fluids I ❑Does Not ' below 55 4F are insulated to zR- ;❑Not Observable ' 3• UNot Applicable 403.4 1 ;Protection of insulation on HVAC ❑Complies ;Requirement will be met. [FR24]1 I piping. I '❑Does Not I 4 ❑Not Observable s i !❑Not Applicable 403 5'3 ,.5 Hot water pipes are insulated to R-., R- ❑Complies ;Requirement will be met. [FR18]z >_R-3. ❑Does Not ❑Not Observable ❑Not Applicable 4036 ;Automatic or gravity dampers are i :❑❑Complies ;Requirement will be met. [FR19]2 installed on all outdoor air I Does Not intakes and exhausts. =06{ ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2•' Medium Impact(Tier 2)� 3" Low Impact(Tier 3) Project Title: Parsons- Sterling Street House Report date: 12/23/21 Data filename: Page 6 of10 5epfion Plans�Vl gi c9 Field veriff!e�iMslattffeck�on 1� e Uatue Gomplies� CommentslAssumptions &Add ID sY .. 303:1 ;All installed insulation is labeled " ❑Complies (Requirement will be met. or the installed R-values ❑Does Not [It�I131 � f � provided. k a � ❑Not Observable 4❑Not Applicable 402.1.1, !Floor insulation R-value. R- R- ;❑Complies ;See the Envelope Assemblies 402.2.6 ❑ Wood 11❑ Wood '❑Does Not ;table for values. [IN1]1 E❑ Steel ❑ Steel ':[]Not Observable ❑Not Applicable 303.2, ;Floor insulation installed per ❑Complies :Requirement will be met. 402.2.8 manufacturer's instructions and ❑Does Not [IN2]1 in substantial contact with the : [-]Not Observable underside of the subfloor, or floor ❑Not Applicable :framing cavity insulation is in !contact with the top side of l3 'R sheathing,or continuous iinsulation is installed on the ` underside of floor framing and j extends from the bottom to the I ; top of all perimeter floor framing ` v ;members. 402.1.1, ;Wall insulation R-value. If this is a R- R- ❑Complies ;See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the El Wood ;❑ Wood ❑Does Not 'table for values. 402.2.E ;wall insulation on the wall ❑ Mass ;❑ Mass ❑Not Observable [IN3]1 exterior,the exterior insulation '❑ Steel ❑ Steel '❑Not Applicable =requirement applies(FR10). Ia I s 77 303.2 Wall insulation is installed per77777777, 'E]Complies Requirement will be met. [IN4]1 f manufacturer's instructions. aP, ❑Does Not ❑Not Observable ❑Not Applicable i � 3s Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) T Low Impact(Tier 3) Project Title: Parsons- Sterling Street House Report date: 12/23/21 Data filename: Page 7 of10 Section Plans'Ver�fsed ' Field<Verifidd Final Inspection Rrov�s�ons Complies' . Comments/Assumptions PIeq.ID Value Value 402.1.1, 'Ceiling insulation R-value. R- ; R- ❑Complies ;See the Envelope Assemblies 402.2.1, ❑ Wood I❑ Wood '❑Does Not ;table for values. 402.2.2, ; ❑ Steel ;❑ Steel ❑Not Observable 402.2.E ; ❑Not Applicable [Fill' � 4 303.1.1.1,;Ceiling insulation installed per ❑Complies Requirement will be met. 303.2 :manufacturer's instructions. I ❑Does Not [FI2]1 ;Blown insulation marked every ❑Not Observable 300 ftz. €. .❑Not Applicable 402 2 3 Vented attics with air permeable ❑Complies ;Exception: Requirement is [FI2�Z]z insulation include baffle adjacent �- F ❑Does Not !not applicable. Ito soffit and eave vents that ;extends over insulation. ; :' �, ❑Not Observable i ❑Not Applicable 402.2 4 ;Attic access hatch and door R- ; R- ❑Complies ;Requirement will be met. [FI3]1 !insulation zR-value of the :❑Does Not ;adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 ;Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies ;Requirement will be met. [FI17]1 :ach in Climate Zones 1-2, and ❑Does Not 3<=3 ach in Climate Zones 3-8. ❑Not Observable ; ❑Not Applicable __..___....__....._....... ___._._ 403.3.3 :Ducts are pressure tested to cfm/100 cfm/100 ❑Complies :Exception: All ducts and air [FI27]1 ;determine air leakage with ftz ftz ❑Does Not F handlers are located within either: Rough-in test:Total ❑Not Observable =:conditioned space. 'leakage measured with a pressure differential of 0.1 inch ❑Not Applicable ; w.g.across the system including ; 'the manufacturer's air handier enclosure if installed at time of !test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch ;w.g.across the entire system 'including the manufacturer's air handler enclosure. ' 403.3.4 1 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies ;Requirement will be met. [FI4]1 cfm/100 ft2 across the system or : ftz ftz ❑Does Not <=3 cfm/100 ft2 without air ❑Not Observable handler @ 25 Pa.For rough-in nests,verification may need to ❑Not Applicable ;occur during Framing Inspection. 403.3.2.1 ;Air handler leakage designated } ❑Complies yRequirement will be met. [FI24]1 by manufacturer at<=2%of # ;❑Does Not design air flow. ❑Not Observable i z❑Not Applicable 4`0 Programmable thermostats ❑Complies ;Requirement will be met. [FI9jz installed for control of primary ❑Does Not heating and cooling systems and ❑Not Observable linitially set by manufacturer to =code specifications. ❑Not Applicable 403 12 ?Heat pump thermostat installed :Requirement will be met. [F110]z on heat pumps. ❑Does Not ❑Not Observable ❑Nat Applicable 4035 1 Circulating service hot water ❑❑Complies Requirement will be met. [Flla]z systems have automatic or Does Not ;accessible manual controls. .: j❑Not Observable ................... r ❑Not Applicable 1 High Impact(Tier 1) 2 = Medium Impact(Tier 2) 31 Low Impact(Tier 3) Project Title: Parsons - Sterling Street House Report date: 12/23/21 Data filename: Page 8 of10 Section Pians Verified Feld Uerif�ed Gompl�es� CommentsJAssumptions Final inspec#ron Provisions Value s value �, 403.E 1 ;All mechanical ventilation system; v -]Complies :Requirement will be met. _ � [FI2Sz fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy s ❑Not Observable ' and air flow limits per Table R403.6.1. ❑Not Applicable 40 2 'Hot water boilers supplying heat tT]Complies Requirement will be met. IF126112 through one-or two-pipe heating E El Does Not 'systems have outdoor setback ❑Not Observable i control to lower boiler water I ❑Not Applicable itemperature based on outdoor , ,.,temperature. 403 5 11 Heated water circulation systems + ❑Complies ;Requirement will be met. [FI28]z have a circulation pump.The �� _ �� ❑Does Not system return pipe is a dedicated ❑Not Observable return pipe or a cold water supply ` ❑Not A licable pipe.Gravity and thermos- PP syphon circulation systems are _ E not present.Controls for fi r circulating hot water system pumps start the pump with signal fi ;for hot water demand within the occupancy.Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and M :. no demand for hot water exists 403.5 1 2 Electric heat trace systems x ❑Complies ;Requirement will be met. [FI29�z comply with IEEE 515.1 or UL =' l ❑Does Not 515.Controls automatically s adjust the energy input to the ❑Not Observable "s heat tracing to maintain the i ;' ❑Not Applicable desired water temperature in the i r P �;y piping. ; 403,E 2, g Demand recirculation water ❑Complies ;Requirement will be met. [F130�2 systems have controls that I ❑Does Not ; ',manage operation of the pump I❑Not Observable ; and limit the temperature of the ❑Not Applicable water entering the cold water Piping to<= 1044F. I 3 F 4d 4 j Drain water heat recovery units � `�� �, �¢ � � ❑Complies ;Requirement will be met. [F13r1 2 tested in accordance with CSA "fi 3 ❑Does Not B55.1.Potable water-side 4 k� xy El Not Observable ; . pressure loss of drain water heat k ;.: ❑Not Applicable i recovery units< 3 psi for d individual units connected to one x 1 or two showers.Potable water- , side pressure loss of drain water l hs x heat recovery units <2 psi for E individual units connected to ,9;three or more showers. _ -- 404.1 90%or more of permanent 3. `❑Complies ;Requirement will be met. [FI611 Ifixtures have high efficacy lamps r f[]Does Not ; x 1 ❑Not Observable '❑Not Applicable 404,1 1 !Fuel as lighting systems have ❑Complies ;Requirement will be met. 9 9 9 [F1231 no continuous pilot light. ❑Does Not ❑Not Observable , � � � .3� �� � ❑Not Applicable ; 4013 ;Compliance certificate posted. .❑complies ;Requirement will be met. z k i�01)oes Not 3 } []Not-Observable ; r s y Applicable Not 1 High pact(Tier 1) 2' Medium Impact(Tier 2) •3', Low I Im mpact(Tier 3) Project Title: Parsons- Sterling Street House Report date: 12/23/21 Data filename: Page 9 of10 1 Sectson Plans Verified Feld Uerrt�ei9 F�nalInspect�on Prouis�ons Comphes� Comments/Assumptsons &Req ID Value 30,33 +Manufacturer manuals for i �,- �❑Complies ;Requirement will be met. [FI18]3mechanical and water heating a E❑Does Not jsystems have been provided. M ❑Not Observable 3 ❑N0t Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2~'Medium Impact(Tier 2) 3' Low Impact(Tier 3) Project Title: Parsons - Sterling Street House Report date: 12/23/21 Data filename: Page 10 of10 2018 IECC Energy Efficiency Certificate Above-Grade Wall 38.50 Below-Grade Wall 15.00 Floor 21.00 Ceiling / Roof 56.00 Ductwork (unconditioned spaces): . . . Rating Window 0.31 0.05 Door 0.20 0.10 Cooling Heating System• Cooling System: Water Heater: Name: Date: Comments AITAlbert•Righter •Tittinann ARCHITECTS Date: 10 March 2022 To: Building Department 54375 Route 25 Southold NY 11971 Re: Mr. &Mrs.J. Geddes Parsons 515 Sterling St. Fishers Island NY 06390 Suffolk Co. tax map #1000-10-9-3.1 Enclosed, to accompany Building Permit application: Combined drawing sets (4): • Architectural drawings • Surveyor's site plan • Structural drawings Supplementary: • D.E.C. Letter of No Jurisdiction • Southold Town Trustees Permit • Suffolk C. Health Dept. Permit 33 Union Street 46.Floor Boston, MA 021.08 617.451.5740 ARTardi.itects.com Jacob.D.Albert James V Righter Jobn R Tiu7na to John B. Clang 1, STRAW BALE BINDER -� DrawingCoPY�9ht©2015 PLASTIC LINING NA(OP V'EMMATERIAL COVER ToPROVIDE a Nc C mA(rw) TEST HOLE DATA 4. �r MPE BY: RH STROUSE P.E.L.S. DATE: 04-22-2021 \ -� \ C-4 SECTION B-B tJ "- " \ WOOD OR NOT TO SCALE 20" : SOR-35 O 1X (MIN) O 12 TOPSOIL WEST METAL STAKES 12"- 26" SANDY SUBSOIL y' 9sOrLito y�� (2 PER BALE) 40"- 204" WELL GRADED COURSE SAND-FEW FINES-SW HARBOR 33 Wilbur Cross Way,Mansfield,Floor 06268 101 East River Drive,1st Floor __ o ° EXPECTED GROUND WATER ELEVAl10N- BELOW ELEVATION 7 �' East Hartford,CT 06108 _ 4" pq - ---- ---- - - 55 I www.c acompanies.com 860-885 10�i2 � �U� BI- .To' MIN . , B NEXT GALLEY �NCW SOIL CLASSIFICATIONS6hll ®® ®® a%_ 0L VARIES I ®®® 111 I %o o EXPECTED and Plymouth very bouldery soils- 15-30% slopes \ I g F I ®®®®®®® I Ck931 CONSTRUCTIOIV ENTRANCE NOT TO !KALE - I I ®®®®®® I SITE `1 -- 0 10" LINING I P • �p�{ '�•��)I STRAW BALE 7' \ \ W 1. REMOVE TOPSOIL AN ORGANICS PRIOR TO PLACEMENT OF CRUSHED STONE. NOT To SCALE I-" 8'-6" I I 2. ENTRANCE SHALL BE 12' WIDE MINIMUM. 3. SUB-BASE OF FREE DRAINING BACKFILL MAY BE USED IIN LIEU OF m E WASNeur PIT COARSE SAND-GRAVEL (SW) z Z GEOTEXTILE FILTER FABRIC. NOTES: 4. MAINTAIN BY TOP DRESSING WITH ADDITIONAL STONE AND REPAIRING RUTS 1. DIMENSIONS SHOWN ARE FOR TYPICAL RESIDENTIAL CONCRETE PUMPS MUST BE SIZED ACCORDINGLY Q GALLONS/TRUCK, AS REQUIRED. ADDITIONAL LENGTH MAY BE REQUIRED IF SEDIMENT IS CONSTRUCTION, LARGER PROJECTS OR PROJECTS REQUIRING LEACHING GALLEY TRACKED ONTO PAVED AREAS. ANY SEDIMENT SPILLED, DROPPED OR r . w . w GROUNDWATER I` TRACKED ONTO PAVED SURFACES SHALL BE REMOVED IMMEDIATELY. 50 GALLONS/PUMP, PLUS MIN. 1' FREEBOARD). 4-9 XS-6 X4-6-� 2 DR,LC rn 2. CAPTURE MATERIAL AND LIQUIDS MUST BE REMOVED FROM NOT TO SCALE HOLE J PIT AND PROPERLY DISPOSED OF WHEN THE PIT REACHES COASTAL, EROSION S rn / 75%OF ITS CAPACITY. HAZARD LINE C / SITE PLAN 3. OF WAT�PIWAP�RIROR TO EACH USE TO ENSURE CONTAINMENT \ \? + �z �� + 9 �O \ PREPARED FOR: NIF • O � ELIZABETH PEISHOFF LIMITS OF.FLOOD ZONE_VE yd'��, \CONCRETE J. GEDDES PARSONS N/F SINGLE FAMILY RESIDENCE FROM FIRM MAP 36103CO019H �� < \ CAP ��` ,�_ 515 STERLING STREET CHARLES W. GREENLEAF SEPTEMBER 25, 2009 5 • FISHERS ISLAND NY "VACANT LAND" MUNICIPAL WATER EXPANSION AREA ram. E \\ �\ '\�s �} ' 1 ON SITE SEPTIC SYSTEM (2 CHAMBERS) I r 8�, N 412, PROVIDE \ \ \ SEA EXIS�NG ALL LOCATION MAP SCALE 1 "=400' SILT FENCE \� \ N 6T34'00" E --MAINTAIN MAINTAIN DURING sra 3.34' N 81.06 30" E 46 -\ CCONSTRUCT ��� ' S�� ` �\ PFLAG OLE \ 35.00' 00" E PROVIDE 4 ' \ \ NOTES 64.8� LEACHING CHAMBERS \ \ \ STOCKPILE ` =_ \ OLD TRAIL ___1 (SEE DETAIL) ��/'�� \��, \ AREA \ \ ;o �\ BENCH MARK 1.) THIS SURVEY WAS PREPARED FOR THE PARTIES AND PURPOSE INDICATED _ bRADE AREA TO 576 \ \ \ \ �„ . \ / \ _ ' HEREON. ANY EXTENSION OF THE USE BEYOND THE PURPOSED AGREED TO PROVIDE T io� `- �� BETWEEN THE CLIENT AND THE SURVEYOR EXCEEDS THE SCOPE OF THE DISTRIBUTION / ENGAGEMENT. � � \ � � � BOX (SEE DETAIL Y W ) r'�, o '� $ �p�� PROVIDE DRY 1 \ 2.) IT IS A VIOLATION OF THE STATE EDUCATION LAW FOR ANY PERSON, � � �. 2 \ FOR ROOF DRAINAGE UNLESS ACTING UNDER THE DIRECTION OF A LICENSED LAND SURVEYOR, TO \ ) PROVIDE 1500 GAL WELLS) ALTER AN ITEM IN ANY WAY. o \ / v ,SEPTIC TANK (SEE DETAIL) \ \ i J \/ \ ^� (SEE DETAIL) o/ / � �r \ 3 \� 3.) ONLY COPIES OF THIS SURVEY MARKED WITH THE LAND SURVEYOR S MONTAUK LLC / / '1 SUBJECT TO RIGHTS ACROSS "RESTRICTED LAND" �\ ?� \ �• V ' r SIGNATURE AND AN ORIGINAL EMBOSSED OR INK SEAL ARE THE PRODUCT OF SINGLE FAMILY ,� // y'�_ AS NOTED IN LIBER 8367 PAGE 58 PROPOSED-2 STORY THE LAND SURVEYOR. ~� \� � y RESIDENCE o ) IN ORDER TO PRESERVE WATER VIEWS` 5 BEDROOM RESIDENCE �-- "1 .<, / L.v FOR ABUTTING PROPERTY \ >z� (FF-22.7) WITH ATTACHED 4. COORDINATE DISTANCES ARE MEASURED FROM U.S. COAST AND GEODETIC MUNICIPAL WATER / � \_ v - '� r \� \\ \ ?6 } \� ' GARAGE (FF-21.33) AND SURVEY TRIANGULATION STATION "PROS" 2X2 5/8 16 GA. t ON SITE SEPTIC SYSTEM// / � �\\ �-� c a \\ o t 25 \ \ o UNFINISHED BASEMENT MARE MESH / / //j ///iglm -1 1 �� (FF-14'16) 5.) SITE IS IN THE TOWN OF SOUTHOLD, COUNTY OF SUFFOLK TAX MAP 1000, 1 1/2" / / PORTION OF SECTION 010, BLOCK 9, LOT 3.1 �- ,/ O -� CENTER OF 10' / `� 1'/ STERLING STREET M / � • / / `'v _ WIDE WATER LINE \ o -�`�� J DISCONTINUED BY 6.) TOTAL AREA = 1.90f ACRES.EXISTING POLE WIDE 6hb`/ / /r' J� C RIGHT OF WAY \ \` 1 THE TOWN DULY 9, 1963 RESIDENCEO / �' L LINE NOT IN \ / �2„ w 1 7.) SITE IS LOCATED IN R-40 ZONE. SERVICE PER ` / 6/ ` I ���`�` (HOLE PROVIDE NEW WATER SERVICE( - FI WATER WORKS \ 3 I .� ;/ // 3 COORDINATE W/FI WATER WORKS 8.) BASE FOR LEVELS, NAVD88 O IT s A MMATION OF LAW FOR ANY PERSON,UNLESS THEY ARE I // i CENTER OF \/ ( it REMOVE EXISTING 9. PERCENT OF LOT COVERAGE PROPOSED- 5.2% m -Al-"I \ \ � ' � � �1 � ) ACTING UNDER THE oIRECTIaI OF A ticENseO PROFESSIONAL 10' WIDE 6+ C // ' '� ,-- RESIDENCE. PUMP EXISTING DONEER.ARCH ECT,LANDSCAPE AKHTM OR LAND Vl i f� SURVEYOR TO,AL1ER m ITEM IN ANY WAY.IF m nEL BEARING 1IE 2" o POLE LINE / \ c 1 / / C O / ; m SEPTIC SYSTEM-ALL 10.) THERE ARE NO DOMESTIC WELLS WITH 150 FEET OF THE PROPOSED STAMP OF A IlCOiSED PNFESSMAL IS ALTERED,7W ALTERING 3 MATERIAL TO BE REMOVED ENQNEER,ARCIMCT,LANDSCAPE ARaMTECT OR LAND 2- / J \ \ RIGHTWAY "` " o w ��'E1 / FROM SITE-(PROVIDE FORM WWM-080) DEVELOPMENT. MO�YaiAL�sOr��BY MA��ttIM S 17'04 00 W N /l DATE OF SUCH ALTERATION,AND A SPECIFIC DESOWTION STANDARD D-BOX ' \ \ • 1 , N I / OF rHE ALTERATION. NOT TO SCALEEMSTING COI\\ �kA % �`► 31.50 ` I + `: ���• ' l CONSTRUCTION N/.GARAGESEP11C SYSTEM DESIGN FOR 5 BEDROOM RESIDENCE \ \ f 4�\ / ip. / N )s ENTRANCE THOMAS J. SHIELD PROVIDE CLEAN-OUT IN BASEMENT- PROVIDE 4" C.I. PIPE TO SEPTIC TANK. SUBJECT TO RIGHTS ACROSS "RESTRICTED LAND \ �- `'O S 3�• SINGLE FAMILY RESIDENCE 5 �R t 8-� (SEE DETAIL) PROVIDE 1500 GALLON SEPTIC TANK- INLET INVERT = 20.0 AS NOTED IN LIBER 8367 PAGE 58 I I �. ?�1b o W MUNICIPAL WATER OUTLET INVERT= 19.75 / IN ORDER TO PRESERVE WATER VIEWS \ CENTER OF \ I I t ► ON SITE SEPTIC SYSTEM PROVIDE 1 DISTRIBUTION BOX- INLET ELEVATION-19.5 168 9g, FOR ABUTTING PROPERTY \ POLE LINE ` 6' SXISTING T � PROVIDE 2 ROWS OF LEACHING GALLEYS (SEE DETAIL)- INLET ELEVATIONS= 19.0 SILT FEPJCE RIGHT OF WAY I s�� GRAVEL a3UREo) 582.94 LEACHING REQUIRED-400 SQ. FT.- PROVIDED- 424 SQ. FT. N 7�5l" W 4g \ r I G1S?s'p0; PARKING Y W 1172.66 CONNECT ROWS OF CHAMBERS AS SHOWN WOVEN WIRE FENCE (MIN. 14 \ ! I I ( �00. F / USE CHAMBERS MANUFACTURED BY DIAMOND PRECAST PRODUCTS GAUGE W/ MAX. 6" MESH I \ � � 1 �� I EXISTING SEPTIC SYSTEM TO BE LOCATED, PUMPED AND SPACING) N/F/ ( ; MARINA A. REMOVED. PROVIDE FORM WWM-080 10' MAX 36" MIN. LENGTH FENCE \ \ \ I ! I ,.� t CENTER TO CEN POSTS DRIVEN MIN. 16" �`o J I TORRANCE & - TER INTO GROUND \ 1 I ; LUCIE T. TURRENTINE ,.� " \ \ S 64 32'00" E I �/ 3 f "VACANT LAND" Abandonment of the existing sanitary system must be in / r I 36.61i \ I ��/'�h�-� TO BE ACQUIRED BY conformance with the Department's requirements.I 1 I' N/F I N 09'2446" E I ,a,� p/ J. GEDDES PARSONS Submit completed form VVWM-080 as proof DAMES & JEANNIE BALLENTINE ` 47.79' / PROVIDE s OMITS OF ) ✓ N h 1 CONCRETE SINGLE FAMILY RESIDENCE z 3 DISTURBANCE STAGING , C7 / \�\ HEIGHT OF " MUNICIPAL WATER o �, 28,000f S.F. ��► \ (SEE DETAIL) 10'-8" FILTER - 16 MIN. p p EASEMENT AREA FOR SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES ON SITE SEPTIC SYSTEM f o� �` �! PARKING- AREA- \ S 25'01 15 W KNOCKOUT INLET AND LJ 1,384t SQ. FT. N 6500 23 W 45.74 OUTLET OPENINGS EMBED FILTER 23.757 0 1 PERMIT FOR APPROVAL OF CONSTRUCTION FOR I'vR�R 15 o� CLOTH A MIN. OF tq SHED �s• SINGLE FAMILY RESIDENCE ONLY 6" IN GROUND "DRY" BUILDING o\ 1 v N 1510.69 RIBS INSIDE BUILDING DEPT. W 201.8-Q TOWN OF SOUTHOLD S25'01'15" W / � / � - R PERSPECTIWE VIEW 17.00' / i � DO - DATE 1/14/2022 H.S. REF. NO. R-21-1737 POE ��� / /° / APPROVED WOVEN WIRE FENCE (MIN. 14 I =// //_� �� ' No. Submittal/Revision " i 160.56' �oc�/ / c� � FOR (MAXIMUM OF 5 BEDROOMS ApP'd By ate 1/2 GAUGE W/ MAX. 6 MESH " CONCRETE CHAMBER RHS 08/12/2021 IRON S 8439 15 w / vo/ //� I EXPIRES THREE YEARS FROM DATE OF APPROVAL DETAIL SPACING) WITH FILTER CLOTH Z PROPOSED ROOF LEADER PIPE RESIDENCE (FOUND) 36" MIN. FENCE POST o CAST � UNDISTURBED N N/F / / %/ / CONCRETE COVERS o ROBERTA C. ELWELL /` / / FLOW-� I GROUND / OVERFFLOW� SINGLE FAMILY RESIDENCE % % PLAN �I COMPACTED $OIL z = 4' Pvc cur / MUNICIPAL WATER TO LENGTH MIN. 6" SOIL COVER ON SITE SEPTIC SYSTEM COVER LOCKING CASTING EMBED FILTER CLOTH \\��\ \� o _ �oVER DRYWELL BLOCKS AND CATCH (0 A MIN. OF 6" IN GROUND �� / -BASIN GRATE TO GRADE %/ IF GRADE TO GRADE (.� L FABRIC / (NEENAH R-2525-F) OR EQUAL / IF DROP 'T' L5 4- FILTER / / IS USED FINISHED GRADE o / CHIMNEY Q SECTION Y(E�l o ® ® ® o N X 20" WIRE MESH LEGEND 90'BEND n O ® ® O m min. m� �4" PROPERTY LINE LLt 4" SDR 35 PVC �-{.-- .- -- CONSTRUCTION SPECIFICATIONS SLOPE AS REQUIRED o ® 0 o O INLET - ABUTTERS LINE U)) % p ® ® po p 4" VENT�16 4" VENT-� OUTLET EDGE OF PAVEMENT V STONE OR p ® ® ® p o LIQUID LEVEL ------------------- (� EDGE OF GRAVEL SCREENED GRAVEL 14" OUTLET � CD 1. WOVEN WIRE FENCE TO BE FASTENED SECURELY TO FENCE POSTS WITH WIRE CONTINUOUS HOT + BAFFLE EXISTING CONTOUR --- 12 --- PROPOSED 5 BEDROOM J TIES OR STAPLES, POSTS SHALL BE STEEL EITHER "T" OR "U" TYPE OR 1' 8' 1' i ASPHALT SEAL IINED WITH PROPOSED CONTOUR 16 RESIDENCE LCt�d HARDWOOD. STORMWATER DRYWELL DETAIL 10' 1/$- PVC I U) 2. FILTER CLOTH TO BE FASTENED SECURELY TO WOVEN WIRE FENCE WITH TIES NOT TO SCALE 8".► DEFLECTOR � STONE WALL r- SPACED EVERY 24" AT TOP AND MID SECTION, FENCE SHALL BE WOVEN WIRE, DRAINAGE CALCULATIONS RETAINING WALL 6" MAXIMUM MESH OPENING. r.. .. FENCE a' ROOF AREA = 3,664 SF TREE LINE 0 3. WHEN TWO SECTIONS OF FILTER CLOTH ADJOIN EACH OTHER THEY SHALL BE 3" �_3" Designed By: Drawn By: Checked By: / OVER-LAPPED BY SIX INCHES AND FOLDED, FILTER CLOTH SHALL BE EITHER CROSS SECTION OVERHEAD WIRES o/w o FILTER X, MIRAFI 10OX, STABILNKA T140N, OR APPROVED EQUIVALENT. REQUIRED = 3,664 SF SF X 2/12 = 611 CF 1 AM FAMILIAR WITH THE STANDARDS FOR APPROVAL NOW OR FORMERLY N/F RHS RAC RHS w 4. PREFABRICATED UNITS SHALL BE GEOFAB, ENVIROFENCE, OR APPROVED DRY WELLS AND CONSTRUCTION OF SUBSURFACE SEWAGE UTILITY POLE -+- Issue Date: Project No: Scale: EQUIVALENT. 611 CF /28.27 CF/VF = 21.6 VF DISPOSAL SYSTEMS FOR SINGLE FAMILY RESIDENCE BOUNDARY POINT O 06-08-2021 069627 1"=30' O 5. MAINTENANCE SHALL BE PERFORMED AS NEEDED AND MATERI/4L REMOVED WHEN USE FOUR(4) - 6'� x s'- DEEP DRY WELLS. AND WILL ABIDE BY THE CONDITIONS SET FORTH 1500 GALLON W "BULGES" DEVELOP IN THE SILT FENCE. THEREIN AND ON THE PERMIT TO CONSTRUCT. 2 COMPARTMENT Drawing No.: SOIL CLASSIFICATIONS SEPTIC TANK 30 15 0 30 / APPLICANT NOT To SCALE SHEET 1 OF 1 RpE-Riverhead and Plymouth very bouldery soils- 15-30% slopes GRAPHIC SCALE IN FEET a� !Illlffl il!!II!l111111 Illlf!IIII Ilfll lllll flfl!IIII IIII IIIIIIIIIIIIIIIIIIIIIIIII SUFFOLK COUNTY CLERK RECORDS OFFICE RECORDING PAGE Type of Instrument: DEED Recorded: 11/29/2021 Number of Pages: 4 At: 03:05:21 PM Receipt Number : 21-0203584 TRANSFER TAX NUMBER: 21-14520 LIBER: D00013131 PAGE: 651 District: Section: Block: Lot: 1000 010.00 09.00 020.000 EXAMINED AND CHARGED AS FOLLOWS Deed Amount: $21,500.00 Received the Following Fees For Above Instrument Exempt Exempt Page/Filing $20.00 NO Handling $20.00 NO COE $5.00 NO NYS SRCHG $15.00 NO EA-CTY $5.00 NO EA-STATE $250.00 NO TP-584 $5.00 NO Notation $0.00 NO Cert.Copies $0.00 NO RPT $200 .00 NO Transfer tax $0.00 NO Comm.Pres $0.00 NO Fees Paid $520.00 TRANSFER TAX NUMBER: 21-14520 THIS PAGE IS A PART OF THE INSTRUMENT THIS IS NOT A BILL JUDITH A. PASCALE County Clerk, Suffolk County ❑1 2 Number of pages RECORDED 2021 Nov 29 03:05:21 PM JUDITH A. PASCALE CLERK, OF This document will be public SUFFOLK COUNTY record.Please remove all L D00013131 Social Security Numbers P 651 prior to recording. DT# 21-14520 Deed/Mortgage Instrument Deed/Mortgage Tax Stamp Recording/Filing Stamps 3 FEES Page/Filing Fee _a ( Mortgage Amt. �-Y 1.Basic Tax Handling 20. 00 2. Additional Tax TP-584 < 6 Sub Total Notation SpecJAssit. . or EA-5217(County) r j= Sub Total 450--(�Z__ Spec./Add. EA-5217(State) •o TOT.MTG.TAX Dual Town Dual County R P.T.S.A. -Held for Appointment Comm.of Ed. 5. 00 TransferTax Affidavit Mansion Tax The property covered by this mortgage is Certified Copy or will be Improved,by a one or two NYS Surcharge is. 00 ��. 000, family dwelling only. Sub Total YES orNO Other C' Jl d O Grand Total J'O`1J V � If N0, see appropriate tax clause on page M ofthis ins rumen. 4 Disc. 29057478 1000 oi000 0900 020000 i0o 5 !Community Preservation Fund T IN1WI Real PropeM [RC WH f1 Consideration Amount$ 21,500 Tax Service Z -0�,2 Agency CPF Tax Due . S .0 Verification----. - _. _�_._ _ (p Improved 6 Satisfactions/Discharges/Releases List Property Owners Mailing Address RECORD&RETURN TO: Vacant Land STEPHEN L.HAM,III,ESQ. �� TD tM MATTHEWS&HAM TD 38 NUGENT STREET SOUTHAMPTON,NY 11968 TD Mail to:Judith A.Pascale,Suffolk County Cleric 7 Title Company Information 310 Center Drive, Riverhead, NY 11901 Co.Name Fidelity National Title Ins. Co. www.suffolkcountyny.gov/clerk Title# 7404-011746 8 Suffolk Coun Recording & Endorsement Page This page-forms part of the attached DEED made by: (SPECIFY TYPE OF INSTRUMENT) MARTHA ELISE TORRANCE The premises herein is situated in and LUCIE TODD TURRENTINE SUFFOLK COUNTY,NEW YORK. TO In the TOWN of SOUTHOLD J.GEDDES PARSONS In the VILLAGE orHAMLETof FISHERS ISLAND BOXES 6 THRU 8 MUST BETYPED OR PRINTED IN BLACK INK ONLY PRIOR TO RECORDING OR FILING. over I CONSI7LT YOUR LAWYER S NING'H S IN§ RUMT EM-mis NSTRUM NT SHOULD E USED BYLAWYERSONLY THIS INDENTURE,made the;?Pday of July,two thousand twenty-one, BETWEEN MARTHA ELISE TORRANCE, 462 Ledge Road, Seekonk, Massachusetts 02771, and LUCIE TODD / TURRENTINE,79 Greenley Road,New Canaan,Connecticut 06840, ✓ party of the first part,and J.GEDDES PARSONS,4 Palm Trail,Hobe Sound,Florida 33455,party of the second part, t WITNESSETH,that the party of the first part,in consideration of Twenty-One Thousand Five Hundred Dollars ($21,500)paid by the party of the second part,does hereby grant and release unto the party of the second part, the heirs or successors and assigns of the party of the second part forever, All that certain plot,piece or parcel of land,situate,tying and being at Fishers Island,Town of Southold,County of Suffolk and State of New York,being more particularly bounded and described as set forth on Schedule A- hereto. _ BEING AND INTENDED TO BE the same premises described as Parcel II in the following deeds:(i)the deed.- made by Walter F.Torrance,Jr.recorded in the Office of the Clerk of the County of Suffolk on December 30,1993 in Liber 11668 at page 289;(ii)the deed made by Walter F.Torrance,Jr.recorded in the Office of the Clerk of the County of Suffolk on March 30,1994 in Liber 11670 at page 574;(Ili)the dead made by Walter F.Torrance,Jr. recorded in the Office of the Clerk of the County of Suffolk on June 2, 1995 in Liber 11727 at page 606;(iv)the deed made by Kimball A.Torrance recorded in the.Office of the Clerk of the County of Suffolk on August 7,2012 in Liber 12701 at page 395;(v)the deed made by Stephen Hosmer Torrance recorded in the Office of the Clerk of the County of Suffolk on January 3,2013 in Liber 12715 at page 860;and(vi)the deed made by Sarah Gager Torrance recorded in the Office of the Clerk of the County of Suffolk on January 3,2013 in Liber 12715 at page 861-. - TOGETHER with all right,title and interest, if any,of the party of the first part in and to any streets and roads abutting the above described premises to the center lines thereof,TOGETHER with the appurtenances and all the estate and rights of the party of the first part In and to said premises;TO HAVE AND TO HOLD the premises herein granted unto the party of the second part,the heirs or successors and assigns of the party of the second part forever. AND the party of the first part covenants that the party of the first part has not done or suffered anything whereby -the said premises have been encumbered in anyway whatever,except as aforesaid. AND the party of the first part,in compliance with Section 13 of the Lien Law,covenants that the parry of the first part will receive the consideration forthis conveyance and will hold the right to receive such consideration as a trust fund to be applied first for the purpose of paying the cost of the improvement and will apply the same first to the payment of the cost of the improvement before using any part of the total of the same for any other purpose.The word"party"shall be construed as if it read"parties'whenever the sense of this indenture so requires. IN WITNESS WHEREOF,the party of the first part has duly executed this deed the day and year first above written. IN PRESENCE OF: Martha Elise Torrance Lucie Todd Turrentine Standard N.Y.B.T.U.Form 8002-Bargain and Sale Deed,with Covenant against Grantor's Acts—Uniform Acknowledgment State of Conne�cticut,County of Fairfield as.:VOW (jZV flWVState of New York,County of ss.: On the c�O p day of July in the year 2021 before me, the On the day of in the year undersigned,personally appeared before me,the undersigned,personally appeared Lucie Todd Turrerdine personally known to me or proved to me on the basis of personally known to me or proved to me on the basis of satisfactory evidence to be the individual whose name is satisfactory evidence to be the individual whose name is subscribed to the within Instrument and acknowledged tome that subscribed to the within instrument and acknowledged to me that she executed the same in her capacity,and that by her signature she executed the same in her capacity,and that by her signature on the instrument,the individual,or the person upon behalf of on the instrument,the Individual,or the person upon behalf of which the Individual acted,executed the Instrument,and that such which the individual acted,executed the instrument Ind11'yyidual(s)made such appearance before the undersigned in At W C4&t *w in the State of Connecticut, Notary Public beq All JA AT-- (signature and office of individual taking acknowledgment) Notary Public (signature and office of individ al taking acmowledgment) . �O Mk LISAMMO • ttoteryt�rbagtitatQatOolmectkut . Nlrtlamnldon�k�ar aL>mxe TO BE USED ONLY WHEN THE ACKNOWLEDGMENT IS MADE OUTSIDE NEW YORK STATE Commonwealth of Massachusetts;County of p as.: &'Lt- pt On the_ day of Pm3tiwtin the year 2021 before me,the undersigned,personally appeared Martha Elise Torrance personally known tome or proved tome on the basis of satisfactory evidence to be the individuals)whose name(s)is(are)subscribed to the within instrument and acknowledged to me that hefshetthey executed the same in hisfierftheir capacity(tes),and that by hislherAheir signatures)on the instrument,the individual(s),or the person upon behalf of which the individual(s)acted,executed the instrument,and that such individuals)made such appearance before the undersigned in 1'"l-a A, in the Commonwealth of Massachusetts. rtl (signature and office of individual taking acknowledgment) (�Ikx 0(1.:L\\4, C--ICSjA -6►p Z)-Q-71--rvL BARGAIN AND SALE DEED DISTRICT 1000 WITH COVENANT AGAINST GRANTOR'S ACTS SECTION 010.00 BLOCK 09.00 Title No.7404-011746 LOTS 020,000 COUNTY OR TOWN SUFFOLK-SOUTHOLD MARTHA ELISE TORRANCE STREET ADDRESS (no#)Sterling Street and LUCIE TODD TURRENTINE Fishers Island,NY 06390 TO J.GEDDES PARSONS RETURN BY MAIL TO: STANDARD FORM OF NEW YORK BOARD OF THE UNDERwRRERS Distributed by RESERVE THIS SPACE FOR USE OF RECORDING OFFICE v/ FIDELITY NATIONAL TITLE INSURANCE COMPANY TITLE NO.7404-011746 SCHEDULE.A-1 (Description of the Land) For Tax Map ID(s): 1000-010.00-09.00-020.000 ALL that certain plat,piece or parcel of land, situate,lying and being at Fishers Island,in the Town of Southold,Suffolk County,State of New York,particularly bounded and described as follows: BEGINNING at the southeast comer of property of Homan B.Porter,conveyed by deed dated August 2,1919,eleven and eight-tenths(11.8)feet North from a large boulder on the westerly side of Sterling Street.From this point the line extends southerly eleven and eight-tenths(11.8)feet to the large boulder at an angle in Sterling Street; Thence the line deflects to the right 20 degrees 0 minutes and extends a distance of twenty(20.0)feet along Sterling Street to a mere stone; Then the line deflects to the right 97 degrees 33 minutes and extends a distance of seventy-five(75.0)feet to a mere stone; Then the line deflects to the right 74 degrees 30 minutes and extends a distance of thirty-one and five-tenths(31.5)feet to a mere stone; Then the line deflects to the right 104 degrees 37 minutes and extends a distance of seventy-five(75.0)feet along the southerly line of Roman B.Porter to the point of BEGINNING. THE POLICY TO BE ISSUED under this commitment will insure the title to such buildings and improvements on the premises which by law constitute real property. FOR CONVEYANCING ONLY: Together with all the right,title and interest of the party of the first part,of in and to the land lying in the street in front of and adjoining said premises. END OF SCHEDULE A Commitment for Title Insurance Printed:06.25.2t @ 11.38AM Schedule A-1 Description NY-F7-FRVH-01030.431004-SPS-1-21-7404-011746 1 rs • �pINSTTMJMIONW-521j4W-INS):wiw.orpsmm.rry.us COUNTY USE ONLY O O i Nm York SdY Depadmwd o1 01.smsbo" I r I I Lq IL a TamdlDn and Finance DaftCL D CWd ReWded I j 2Q/ 2.1 I O Real Ptopeny Tex Serv)xs �. �- RP-5217-PDF Ca.Beall Ca.Ppa Real Prop"Tearaft lep M PRO) PROPERTY O1FORNATNM %P'QWy (ro 4) STERLING STREET laeaeon •84aE•Ria •bred•MrL TOWN Or S06TLOLO ?ISREHS ISLAND 06390 •tan ORTaw vuAGI Moab 2.Buyer PARS04S J. GEDD?S IYms _r.WIFA M.4kV rwarrw Uui wRCOpm, r•psr more �.TON trmdran whoa Mum TO Bab n to be sem =no d wwtho buyer empesrld Ewan d famq mAv anrrni trr rvarxua Addeee Man-gaftAANDUMV W-TWraMn MAIL ZPaan. 4.idastallms mI ofAesesadwd 1 YdPnala 011 ❑PWVfdFWW (OnlyrpatdePMCQ Check asffeyapplln Rd pneei twasiernd m ft dud M.frlwaft 0=6 ah Mh&A hen Aufha ft Edge L Ond X OR 0.0 6 4L Sulnaadm Approval wse RsquW dfa invader El PMPerb -mmwpm- •mxp:r• •cues Ike 4Q Parcel Approved Nor Subddamnwltlm lip PraNded TORRANCE YARTRA ELSE &sow -ulf"Waavaw -WIVAe man TUPREN^IN9 ium TODD LARNUCcoevw raarwmE 17.3sbcadmads akftnatdehmastsrsurd*daaeresedo Mock do boxes Edonr they apply: mofthepmopIVetthedmofadr.. LOmmm lPTWwIsCadwWfdm C.Resithmf la)Vaeem Land L New Consbudlon an a Vmznk lad 1CA.Pmpeny Looted rfdin en Ap bwltur l Daald 10L Buyer modeed a rI reear miles Indtdapthd the pooty is In en Ayfenird DhEid ISALE lf2t�MATION 1LCh alfw«moreddommrdtlorreaNPllasbimtrmmler A.Sde Beepam Relatives or Fanner Rehouse 11.amWCmbsetDsi 07/26/2021 B,aetebe' ROM ComprworPamomiInewnesm C.On dare Buysms Is We m Soler m1s11.mdflrrTr.msMr 08/04/2021 ftdm e�Tomadd ftler'Cmwmmt+Nrr e.rpyla.dswl�Below) F.Ssle of Rmcw d or Lase Mm Fes Iriavd 0Spu4 8sbeq '11I.FMB SaiP&A 21,500.()0 0.RprdandCWW In frmopady BN~TMMd§Bubo dd sde Darr lL Bale al Bfairaaa a Ymdu ed In Bs" Pnse IFutBdePmlubOrlodooadpaidlmerprbpugfbdWrpl+emmdPrapvny I.other Unusual FamnAlieftSdsPm(SP"Btdwm) TNs paynnartt may ba im dalbrm d cmk dEsr promty orpooft a thamxerarVfift OF J.Nan rmwerpepwrorathuaEl wm)1AI MwWiogwnmmdwbobdoeerameatf ymCandlbon: t<iedosm on vaius of persoael 0.Clo pmpnll hw aw i du sei ASSFSSMEM INFORMATION-Doi should rolled mo Mast Final At40aament Roll WW Tax EM ILYearofAvessemndRmdlhmawI&I W aosSmiisigM 20 'ty TOdA�� 200 -I&RepwtyCho 311 _ ,^ •1a.aamm)fmlatiarae FISHERS ISLAND 'i0.Tea 14p Maellld(vyRoa IdwmisdrW pf mondan fommr,efidl gaetwab arlmlUanal tdna/Ym(p) 1000-C:0.00-09.00-020.000 [EMFr_ATWN 1 Goy drr d db rw d YdaearaBan emdwvd m tlda foam aA rcie bad aarrest pD rn Wstd ry enawidpeand bell"and 1 uridamvtad ama tls maiip dermy wl�d tmmetaeraentalsuhAdbd bomb m medanmthRlOdy14 immemlrYMpand"offetseirdnarads. frraweemnam IbrvnbLW.Nr4Ldamee•bLLCAod@4.nmdeem•ampwserLimel"mepsy.amma w p@aft googvrm mnm an em6�Ambmmlarsdwry.arrero ow b..42W eirmpondenndrduNeepmwam p'b'waatn urwra�wps�oer mralra.0e..nne 7yprpna aeab.) �um� ^ wrL PARSONS J. GEDDES I;�+ h/•` all/L' Ll ;.eerwva rorwra (40-) 369--2 456 `f y) WWAwoe mum anMSrAWAL we 4 PAe.N. TRAIL •wt%&l mum" 'ete�r rarC ROSE SOUND FL 33455 %r:TAromm 7IaT '1P cm fief HAM STEPHEN L., III w'wire PAST-use (631) 283-2400 wueaaP rumm "Ammed,mamse/ r 11111111111 Illliilll Illllilll _ IIIIIIIII Iilllllllll IIIIII IIII11 IIIIIIIII IIIIIIIIII SUFFOLK CONY CLERK RECORDS OFFICE RECORDING PAGE Recorded: 11/29/2021 Type of Instrument: EASEMENT At: 03:05:21 PM Number of Pages: 7 Receipt Number : 21-0203584 LIgER: 1)00013131 TRANSFER TAX NUMBER: 21-14521 PAGE: 652 District: Section: Block: Lot: 1000 010.00 09.00 003.001 EXAMINED AND CHARGED AS FOLLOWS Deed Amount: $100.00 Received the Following Fees For Above Instrument Exempt Exempt Page/Filing $35.00 NO Handling $20 .f NO COE $5.00 NO NYS SRCHG $15 0 NO TP-584 $5.00 NO Notation $100 NO Cert.Copies $0.00 NO RPT $ / 00 NO Transfer tax $0.00 NO Comm.Pres. 5.00 NO Fees Paid f0. 00 TRANSFER TAX NUMBER: 21-14523. THIS PAGE IS A PART OF THE INSTRUMENT THIS IS NOT A BILL JMITH A. PASCALE County Clerk, Suffolk C Y 1 RECORDED Number of pages - 2021 Nov 29 03:05:21 PM JUDITH R. PASCALE CLERK OF This document will be public SUFFOLK COUNTY P L D000I3131 record.Please remove all P 652 Social Security Numbers DT# 21-14521 prior to recording. Deed/Mortgage Instrument Deed/Mortgage Tax Stamp Recording/Filing Stamps 3 FEES Page/Filing Fee --a2l -00 Mortgage Amt. -1.Basic Tax Handling 20. 00 2. Additional Tax TP-584 L 00 Sub Total N SpecJAssit. Notation ' or EA-52 17(County) Sub'Total C;0'00 Spec./Add. ,EA-5217(State) TOT.MTG,TAX R.F:T.S A. 'yff Dual Town Dual County Held for Appointment J Comm.of Ed. S. 00jzi Transfer Tax Cr Affidavit T a Mansion Tax Certified Copy The property covered by this mortgage is or will be Improved,by a one or two NYS Surcharge 15. 00 famllydwelling only. . Sub Total _ YES or NO Other — Grand Total �' D00 If NO, see appropriate tax clause on page# of this instrument. :4]�Di'stl4668318tpjmf�n7p"I�IIn�+�1 I{� 01 5 1 Community Preservation Fund Real Property RPH �A II��`�IIIIIIIII{IIIIIII{W�Nu� Consideration Amount$ � Tax Service IIIIII�IINIiIIUU Vul 11��11111, Agency 25-OCT-2 CPF Tax Due $ Verification - ---- ---- - --- Improved 6 Satisfactions/Discharges/Releases List Property Owners Mailing Address RECORD&RETURN TO: Vacant Land STEPHEN L.HAM,III,ESQ. TD MATTHEWS&HAM TD 38 NUGENT STREET SOUTHAMPTON,NY 11968 TD Mail to:Judith A.Pascale,Suffolk County Clerk 7 Title Company Information 310 Center Drive, Riverhead, NY 11901 Co,Name www.suffolkcountyny.gov/clerk Title# '1 qG -0 11-1 8 Suffolk County Recording & Endorsement Page This page forms part of the attached GRANT OF EASEMENT made by: (SPECIFY TYPE OF INSTRUMENT) J.GEDDES PARSONS The premises herein is situated in SUFFOLK COUNTY,NEW YORK. TO In theTOWN of SOUTHOLD MARTHA ELISE TORRANCE In the VILLAGE and LUCIE TODD TURRENTINE or HAMLET of FISHERS ISLAND BOXES 6 THRU 8 MUST BE TYPED OR PRINTED IN BLACK INK ONLY PRIOR TO RECORDING OR FILING. over pT S R CWH A Stat ID: 4668318 25-OCT-21 Tax Maps District Secton Block Lot School District kv 1000 01000 0900 003001 FISHERS ISLAND 1000 01000 0900 005001 FISHERS ISLAND r GRANT io QL11Vj,,t2F S ME IT THIS GRANT OF EASEMENT is made as of the 2 S day of July, by J. Geddes Parsons, residing at 4 Palm Trail, Hobe Sound, Florida 33455 ("Grantor"), to Martha Elise Torrance,residing at462 Ledge Road,Seekonk,Massachusetts 02771,and Lucie Todd Turrentine, residing at 79 Greenley Road, New Canaan, Connecticut 06840 (collectively, "Grantee"); WITNESSETH : WHEREAS, Grantor is the owner in fee simple of a parcel of land located at Sterling Street, Fishers Island,Town of Southold, County of Suffolk and State of New York (SCTM No. 1000-010.00-09.00-003.001), more fully described in Schedule A attached hereto ("Grantor's Premises"); and WHEREAS, Grantee is the owner in fee simple of a parcel of land located at Sterling Street, Fishers Island, Town of Southold, County of Suffolk and State of New York (SCTM No. 1000-010,00-09.00-005.001), more fully described in Schedule B attached hereto ("Grantee's Premises"); and WHEREAS, simultaneously with the execution and delivery hereof, Grantee is conveying a parcel of land to Grantor which has heretofore been used for the parking of vehicles by parties occupying,servicing,visiting or otherwise using Grantee's Premises; and WHEREAS, as partial consideration for such conveyance, Grantor has agreed to convey to Grantee a permanent easement over a portion of Grantor's Premises for the benefit of Grantee's Premises for the parking of motor vehicles by Grantee and others who may be occupying, visiting, servicing or otherwise using Grantee's Premises; NOW,THEREFORE,in consideration of the sumof Ten Dollars($10.00)and other good and valuable consideration paid by Grantee to Grantor, the receipt and sufficiency of which are hereby acknowledged, Grantor hereby grants and releases unto Grantee and Grantee's heirs, personal representatives, successors and assigns, as appurtenant to and for the benefit of Grantee's Premises,a permanent easement on,over,across and through the Easement Area described below for the use, construction, installation, operation, maintenance, repair, improvement and replacement of at least four surface level parking spaces for the parking of motor vehicles(the"Parking Spaces"), Grantor acknowledges and agrees that Grantee shall have the right to permit others who may be occupying,visiting, servicing or otherwise using Grantee's Premises, including but not limited to Grantee's tenants, visitors,guests, contractors and licensees(but not the general public),to use the Parking 1 Spaces. To the extent permitted by law, the Parking Spaces may also be used for the parking of a boat trailer and boat. The Easement Area covered by this Grant of Easement is described as follows: All that certain plot,piece or parcel of land,situate, lying and being at Fishers Island,Town of Southold,County of Suffolk and State of New York,being more particularly bounded and described as follows, BEGINNING at a point on the westerly line of Sterling Street,said point being located 1510.69 feet North of a point which is 201.89 feet West of a monument marking the United States Coast and Geodetic Survey Triangulation Station "PROS"; and RUNNING THENCE North 65 degrees 00 minutes 03 seconds West, 23.75 feet to a point; THENCE North 09 degrees 24 minutes 46 seconds East, 47.79 feet to a point; THENCE South 64 degrees 32 minutes 00 seconds East, 36.61 feet to a point on the westerly line of Sterling Street; THENCE along the westerly line of Sterling Street South 25 degrees 01 minute 15 seconds West, 45.74 feet to the point or place of BEGINNING. Containing 1,384 square feet, more or less. This Grant of Easement shall run with the land and be binding upon and inure to the benefit of the respective heirs, personal representatives, successors and assigns of Grantor and Grantee. IN WITNESS WHEREOF, Grantor has executed this Grant of Easement as of the day and year first above written. J. Geddes Parsons 2 STATE OF RHODE ISLAND ) ss.. COUNTY OF PROVIDENCE ) On the Z 8 day of July in the year 2021 before me,the undersigned, personally appeared J. Geddes Parsons personally known to me or proved to me on the basis of satisfactory evidence to be the individual whose name is subscribed to the within instrument and acknowledged to me that he executed the same in his capacity, and that by his signature on the instrument,the individual, or the person upon behalf of which the individual acted, executed the instrument, and t t such individual made such appearance before the undersigned in the G� Ey of hV!de+ecp-, in the State of Rhode Island. (insert the City or other political subdivision) Notary Public, SAO,& llil:lde Island Notary Public#32340 State of Rh Island 3 Schedule A to Grant of Easement Grantor: J. Geddes Parsons Grantee: Martha Elise Torrance and Lucie Todd Turrentine Grant of Easement Dated: July Z$ , 2021 Parsons Pro a SCTM#1000-010.00-09.00-003.001 All that certain plot, piece or parcel of land, with the buildings and improvements thereon erected, situate, lying and being at Fishers Island, Town of Southold, County of Suffolk and State of New York, being more particularly bounded and described as follows: BEGINNING at a stone monument set on the westerly side of Sterling Street, said monument being located 1582.94 feet North of a point which is 172.66 feet West of another monument marking the U.S. Coast and Geodetic Survey Triangulation Station "PROS"; and RUNNING THENCE North 58 degrees 12 minutes 00 seconds West, 75.37 feet; THENCE South 17 degrees 04 minutes 00 seconds West, 31.50 feet; THENCE South 57 degrees 26 minutes 00 seconds East, 75.00 feet to the westerly line of Sterling Street; THENCE along the westerly line of Sterling Street South 25 degrees 01 minute 15 seconds West, 78.84 feet; THENCE along the westerly side of Sterling Street South 25 degrees 01 minute 15 seconds West, 17.00 feet to an iron.pipe; THENCE South 84 degrees 39 minutes 15 seconds West, 160.56 feet to an iron pipe; THENCE North 03 degrees 06 minutes 40 seconds West, 114.34 feet to an iron pipe; THENCE North 77 degrees 14 minute 51 seconds West, 168.98 feet to an iron pin which is North 44 degrees 22 minutes 00 seconds East, 74.36 feet from a monument on the 4 southeasterly line of Montauk Avenue, said monument being 1548.63 feet North of a point which is 605.97 feet West of a monument marking the U. S. Coast and Geodetic Triangulation Station "PROS"; THENCE North 44 degrees 22 minutes 00 seconds East, 206.54 feet to a stone monument; THENCE North 67 degrees 34 minutes 00 seconds East,3.34 feet to a stone monument; THENCE North 81 degrees 06 minutes 30 seconds East, 64.80 feet to a monument; THENCE North 76 degrees 07 minutes 25 seconds East,46.07 feet to a drill hole in a wall; THENCE North 69 degrees 34 minutes 50 seconds East,47.21 feet to a stone monument; THENCE North 49 degrees 50 minutes 10 seconds East, 55.80 feet to a drill hole in the face of a retaining wall at the shore of West Harbor; THENCE ALONG West Harbor the following two (2) courses and distances: (1) South 51 degrees 22 minutes 54 seconds East, 95.87 feet; and (2) South 65 degrees 41 minutes 00 seconds East, 35.00 feet; THENCE South 32 degrees 00 minutes 36 seconds West, 117.98 feet partly along the northwesterly line of Sterling Street to a drill hole; THENCE along said street line South 05 degrees 01 minute 40 seconds West, 67.32 feet to the monument set at the point or place of BEGINNING. 5 Schedule B to Grant of Easement Grantor: J. Geddes Parsons Grantee: Martha Elise Torrance and Lucie Todd Turrentine Grant of Easement Dated: July2 5��021 Torrance/Turrentine Property (SCTM# 1000-010.00-09.00-005.001) All that certain plot, piece or parcel of land, with the buildings and improvements thereon erected, situate, lying and being at Fishers Island, Town of Southold, County of Suffolk and State of New York, being described as follows: A certain piece or parcel of property, together with the buildings standing thereon, more particularly described in a certain deed of George W. Roberts and Nellie A.Roberts, both of Hartford, Connecticut, to David Torrance, of Derby CT, said being dated October 9, 1885, and recorded in the Suffolk County Clerk's Office in Book 291 of Deeds, Page 411. Said premises being so described as Parcel I in the following deeds of record: (i)the deed made by Walter F.Torrance, Jr.recorded in the Office of the Clerk of the County of Suffolk on December 30, 1993 in Liber 11658 at page 289; (ii) the deed made by Walter F. Torrance, Jr. recorded in the Office of the Clerk of the County of Suffolk on March 30, 1994 in Liber 11670 at page 574; (iii)the deed made by Walter F.Torrance, Jr. recorded in the Office of the Clerk of the County of Suffolk on June 2, 1995 in Liber 11727 at page 606; (iv)the deed made by Kimball A. Torrance recorded in the Office of the Clerk of the County of Suffolk on August 7, 2012 in Liber 12701 at page 395; (v) the deed made by Stephen Hosmer Torrance recorded in the Office of the Clerk of the County of Suffolk on January 3, 2013 in Liber 12715 at page 860; and (vi) the deed made by Sarah Gager Torrance recorded in the Office of the Clerk of the County of Suffolk on January 3, 2013 in Liber 12715 at page 861. 6 ICC E EVALUATION IMES Evaluation Report ESR-1662 Reissued August 2020 Revised February 2021 This report is subject to renewal August 2022. www-icc-es.orq 1 (800) 423-6687 1 (662) 699-0643 A Subsidiary of the International Code Council° DIVISION: 03 00 00—CONCRETE Attributes verified: Section: 03 41 00—Precast Structural Concrete ■ See Section 3.0 REPORT HOLDER: 2.0 USES SUPERIOR WALLS OF AMERICA, LTD. The Superior Walls Xi and Xi Plus Precast Concrete Foundation Walls (including basement walls) are used to EVALUATION SUBJECT: support wood frame construction. SUPERIOR WALLS Xi AND Xi PLUS PRECAST 3.0 DESCRIPTION CONCRETE FOUNDATION WALLS The Superior Walls Xi and Xi Plus Precast Concrete ADDITIONAL LISTEES: Foundation walls are formed from 5,000 psi (34.4 MPa) compressive strength normal-weight concrete that contains SUPERIOR WALLS BY ADVANCED CONCRETE synthetic fibers. SYSTEMS,INC. Superior Walls Xi and Xi Plus Precast Concrete Foundation Walls consist of a 13/4-inch-thick (44 mm) SUPERIOR WALLS OF CENTRAL VIRGINIA exterior face shell, monolithically cast with 101/4-inch-wide (260 mm) top and bottom bond beams, and 21/4-inch-by- SUPERIOR WALLS BY COLLIER FOUNDATION 71/2-inch (57 mm by 190.5 mm) concrete studs at SYSTEMS INC. 24 inches(610 mm)on center. SUPERIOR WALLS OF EAST TENNESSEE The only difference between the Xi and Xi Plus is that the shell is bonded to various combinations of rigid foam SUPERIOR WALLS SYSTEMS, LLC boards on the inside face. For the the Xi product, there are DBA: SUPERIOR WALLS OF NORTH CAROLINA three insulation options: the first is .21/2-inch-thick (63.5 mm) rigid cellular polystyrene; the second option is SUPERIOR WALLS OF NEW JERSEY an insulation assembly consisting of 2-inch (50.8 mm) rigid cellular polystyrene and a 1/2-inch (12.7 mm) layer of SUPERIOR WALLS OF UPSTATE NEW YORK polyisocyanurate insulation; and the third option is an insulation assembly consisting of 11/2-inch (38.1 mm) rigid SUPERIOR WALLS BY WEAVER PRECAST cellular polystyrene and a 1-inch (25.4 mm) layer of polyisocyanurate insulation. The Xi Plus product consist of GREAT LAKES SUPERIOR WALLS a 5-inch insulation assembly consisting of 41/2-inch (114.3 mm) rigid cellular polystyrene and a 1/2-inch 1.0 EVALUATION SCOPE (12.7 mm) layer of polyisocyanurate insulation on the inside face for the Xi Plus. Each stud is wrapped with Compliance with the following codes: 1-inch-thick(25.4 mm) expanded polystyrene insulation on ■ 2018, 2015, 2012, 2009 and 2006 International Building three exposed sides and faced with a galvanized steel Code®(IBC) channel for interior finish fastening. Chase openings with knockouts are provided in each stud for plumbing and ■ 2018, 2015, 2012, 2009 and 2006 International electrical wiring. All insulation is factory installed to the Residential Code®(I RC) precast concrete walls and must be as described in Properties evaluated: Superior Walls'approved quality control documentation. ■ Structural Panels are available in heights of 4 feet (1219 mm), ■ Fire-resistance rating 8 feet 2 inches (2489 mm), 9 feet (2743 mm) and 10 feet ■ Surface burning characteristics (3048 mm), with corresponding weights of 170, 303, 329 and 361 Ib/ft (253, 451, 490 and 537 kg/m), respectively. ■ Dampproofing The panels are available in various lengths. See Figures 1 ■ Thermal Barrier and 2. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as i to anyfinding or other matter in this report,or as to any product covered by the report. Copyright©2021 ICC Evaluation service,LLC.All rights reserved. Page 1 of 5 ESR-1662 I Most Widely Accepted and Trusted Page 2 of 5 The attributes of the wall panels have been verified as beams, to transfer loads induced by lateral loads in the conforming to the provisions of (i) CALGreen Sections plane of the wall, is limited to 1,500 Ibf (6675 N). See A4.404.3.3 for premanufactured building systems; (11) ICC Figure 4 for typical details. 700-2015 and ICC 700-2012 Section 601.5 and 11.601.5 Details involving openings in the foundation walls have for prefabricated components; and (iii) ICC 700-2008 not been evaluated and are beyond the scope of this Section 601.5 for prefabricated components. Note that report. decisions on compliance for those areas rest with the user of this report. The user is advised of the project-specific The Superior Xi and Xi Plus walls must be laterally provisions that may be contingent upon meeting specific supported at the top and bottom of the panels. conditions, and the verification of those conditions is 4.2 Fire-resistance-rated Wall Construction: outside the scope of this report. These codes or standards often provide supplemental information as guidance. With the addition of two layers of 5/a-inch(15.9 mm)Type X 4.0 DESIGN AND INSTALLATION gypsum wallboard complying with ASTM C1396, attached to the stud facing in accordance with the applicable 4.1 Design Details: code, Superior Walls Xi and Xi Plus walls with a Backfill material must not exceed 100 Ibf/ftz/ft maximum allowable axial compressive load of 3,000 Ibf/ft (1602 kg/m2/m) equivalent fluid pressure for the 4-foot (43 779 N/m) (including ledger loads) have a two-hour (1219 mm), 8-foot-2-inch (2489 mm), 9-foot (2743 mm) fire-resistance rating. and 10-foot tall (3048 mm) Superior Walls. The walls have 4.3 Dampproofing: a combined (ledger plus wall loads above the foundation wall) maximum allowable axial compressive load of Superior Walls Xi and Xi Plus walls have been evaluated 7,500 Ibf/ft(109,453 Wm). as an alternative method of providing foundation wall Use of Superior Walls Xi and Xi Plus walls with a dampproofing; therefore, no additional dampproofing is brick ledge is limited to an allowable load of 2,900 Ibf/ft required. (42 320 N/m) on the brick ledge, which is to be considered 4.4 Thermal Barrier: as part of the allowable load of the wall noted in this section. A code-prescribed thermal barrier separating the foam Above-grade foundation stem wall applications in which plastic from the interior of the building is not required based on testing conducted in accordance with Section negative transverse loads (such as leeward side wind 2603.9 of the 2018, 2015, 2009, and 2006 IBC (Section pressure) in accordance with the applicable code are 2603.10 of the 2012 IBC) and Section R316.6 of the IRC developed, must be limited to applications where the (Section R314.6 for the 2006 1RC). negative design wind pressure does not exceed 80 psf (3.83 kN/m2). Above-grade foundation stem wall 4.5 Installation Details: applications in which positive transverse wind loads, in Superior Walls Xi and Xi Plus walls must be installed in accordance with the applicable code, are developed must accordance with this report and the design details and be limited to applications where the allowable wind calculations, as noted in Section 5.5 of this report. pressure does not exceed 155 psf(7.42 M ). The allowable racking shear load on the Superior Xi and Construction details noted in Superior Walls documents Xi Plus foundation walls is limited to a maximum of 500 plf such as the Builder Guideline Booklet, have not been (7300 N/m). Construction using the Superior Walls Xi and evaluated and are beyond the scope of this report. Xi Plus system is limited to those Seismic Design 5.0 CONDITIONS OF USE Categories specified in Section 5.7. Use of Superior Walls Xi and Xi Plus walls with beam The Superior Walls Xi and Xi Plus Precast Concrete Foundation Walls described in this report comply with, or pockets utilizing two support studs is limited to applications are suitable alternatives to what is specified in, those where the maximum allowable load applied to the beam codes listed in Section 1.0 of this report, subject to the pocket does not exceed 16,000 Ibf (71 200 N) for a following conditions: 10-foot-high (3048 mm) panel and 13,000 Ibf (57 800 N) for shorter heights. Other beam pocket configurations are 5.1 Superior Walls Xi and Xi Plus walls must be outside the scope of this report. manufactured, identified and installed in accordance Beam pockets must be designed and constructed in with this report and the information required by accordance with the details, dimensions and specific Section 5.5 of this report. loading limitations given in the engineered design 5.2 Where underground water investigation, required by drawings. See Figure 3 for typical beam pocket details. the applicable code, indicates that a hydrostatic Design of the footing supporting Superior Walls Xi and Xi pressure condition exists, the foundation wall must be Plus walls must be in accordance with the applicable code. waterproofed in accordance with the applicable code. The footing must extend below the frost line of the locality, Evaluation of the waterproofing material is outside the as required by the applicable code. scope of this report. For jurisdictions adopting the IRC, installation of Superior 5.3 Connection of adjacent Superior Walls Xi and Xi Plus Walls Xi and Xi Plus walls on gravel footings is permitted walls must be inspected to verify application of the as noted in IRC Section R401.2, provided the construction sealant and bolts in accordance with the submitted details comply with Section R403.4 and the details noted in design drawings. Table 1 of this report. 5.4 Soil capacity of the site must be consistent with the The capacity of the bolted connection at the top and requirements of the applicable code. For jurisdictions bottom of the panels, using 1/2-inch-diameter-by-21/2-inch- adopting the IRC, the soil capacity of the site, in lieu long (12.7 mm by 63.5 mm) hex head bolts through the of a complete geotechnical evaluation, must be bond beams and a 1/2-inch-diameter-by-51/2-inch-long assumed to have the load-bearing values specified in (12.7 mm by 140 mm) hex head bolt through the footing IRC Table R401.4.1. ESR-1662 1 Most Widely Accepted and Trusted Page 3 of 5 5.5 Design calculations and drawings must be submitted 7.0 IDENTIFICATION to the code official for approval. The documents must 7.1 Each Superior Walls Xi and Xi Plus precast panel be prepared by a registered design professional must bear a label with the evaluation report number where required by the statutes of the jurisdiction in (ESR-1662). The label must be attached at mid- which the project is to be constructed. The design height, near the center of each wall panel. calculations and details must address, at a minimum, Additionally, each project must have at least one label the following: on the foam insulation of one panel noting the name ■ Details of waterproofing, if applicable. of the manufacturer,the name of the installer, and the ■ Depth of footing and footing specifications manufactured and installation dates. consistent with this report. 7.2 The report holder's contact information is the ■ Investigation of resistance to overturning and uplift following: forces. SUPERIOR WALLS OF AMERICA, LTD. ■ Details for lateral support of the top and bottom of 937 EAST EARL ROAD Superior Walls Xi and Xi Plus walls. NEW HOLLAND, PENNSYLVANIA 17557 (800)452-9255 ■ Verification that the loading requirements at the www.superiorwalls.com jobsite do not exceed the allowable loads and details (including the foundation details) noted in 7.3 The additional listees' contact information is the Section 4.1 of this report. The calculations must following: include verification that the combined loading SUPERIOR WALLS BY ADVANCED CONCRETE conditions, such as out-of-plane and vertical loads, SYSTEMS,INC. do not exceed the allowable loads noted in this 55 ADVANCED LANE report. MIDDLEBURG, PENNSYLVANIA 17842 5.6 Installation must be done by Superior Walls—certified SUPERIOR WALLS OF CENTRAL VIRGINIA installers. 10101 SUPERIOR WAY 6.7 Superior Walls Xi'and Xi Plus walls used as lateral AMELIA,VIRGINIA 23002 force—resisting systems are limited to Seismic Design SUPERIOR WALLS BY COLLIER FOUNDATION Category A or B under the IBC and to Seismic Design SYSTEMS INC. Category A, B or C under the IRC. 1600 ELLSWORTH AVENUE, SUITE 210 6.8 Superior Walls must be manufactured at the locations HEIDELBERG, PENNSYLVANIA 15106 noted under "Additional Listees" in this report, in SUPERIOR WALLS OF EAST TENNESSEE accordance with the Superior Walls of America, Ltd., 10144 SPARTA HIGHWAY Quality Assurance Manual, dated September 2014, ROCK ISLAND,TENNESSEE 38581 and with inspections by ICC-ES. SUPERIOR WALLS SYSTEMS, LLC 6.0 EVIDENCE SUBMITTED DBA: SUPERIOR WALLS OF NORTH CAROLINA 6.1 Data in accordance with the ICC-ES Acceptance 3570 SOUTH MAIN STREET Criteria for Foam Plastic Insulation (AC12), dated SALISBURY, NORTH CAROLINA 28147 June 2015 (Editorially revised May 2016), including a SUPERIOR WALLS OF NEW JERSEY report of a fire test in accordance with 2603.9 of the 92 REESE ROAD 2015, 2009, and 2006 IBC (Section 2603.10 of the MILLVILLE, NEW JERSEY 08332 2012 IBC). SUPERIOR WALLS OF UPSTATE NEW YORK 6.2 Results of water permeability tests conducted in 7574 EAST MAIN ROAD accordance with ASTM E96. LIMA, NEW YORK 14485 6.3 Data in accordance with the ICC-ES Acceptance SUPERIOR WALLS BY WEAVER PRECAST Criteria for Concrete Floor, Roof and Wall Systems 824 EAST MAIN STREET and Concrete Masonry Wall Systems (AC15), dated EPHRATA, PENNSYLVANIA 17522 February 2010 (Editorially revised February 2019); GREAT LAKES SUPERIOR WALLS including reports of beam pocket tests. 4555 134TH AVENUE 6.4 Report of fire-resistance tests conducted in HAMILTON,MICHIGAN 49419 accordance with ASTM E119. ESR-1662 I Most Widely Accepted and Trusted Page 4 of 5 S� TABLE 1—MINIMUM DEPTH OF CRUSHED STONE FOOTING(inches) SOIL TYPE AND LOAD BEARING CAPACITY(psf) CONSTRUCTION TYPE 1,500 2,000 3,000 (Assumed Wall Loading) SC,GC,SM,GM 4,000 MH,CH,CL,ML SP,SW GP,GW Conventional Light-frame Construction 1-story (1,100 pounds per linear foot) 4 4 4 4 2-story (1,800 pounds per linear foot) 4 4 4 4 3-story (2,900 pounds per linear foot) 12' 8 4 4 Masonry Veneer over Light-frame Construction 1-story (1,500 pounds per linear foot) 4 4 4 4 2-story (2,700 pounds per linear foot) 10' 6 4 4 3-story (4,000 pounds per linear foot) 20' 12' 6 4 For SI: 1 inch=25.4 mm, 1 psf=0.0479 kN/mz, 1 plf=14.6 N/m. 'Stone must be vibrated in a maximum 8-inch lifts. LATERAL SUPPORT BY IOIBTS AND/OR BLOCKIf(4 SUPL•RIOR WA1 S AS SPECIFIED BY AS DL•SCRIDLDBY / CONSTRUCTtON VOCUIMMNIS THIS REPORT CHASH OP&.WL*1G (TYPICAL) 114 INCH FACE SHELL {\ •,y,r�v.� � •.,F.\/�� r\\ `:,' %l .- �'Gl{By 7�?I21LI17 iiONLRETE&MM. 24 INCHES ON C&MR %1l' _:/'..>'• ,,4%`:.\v�•.. ;fi��'•''�'✓• i i ''Y /...GAI.YhNtZED STI,'D FACING , xN 'i j`✓ ti? y>',.; '�� I ' FOAM PLAS77C TNSULAT70N ('•,.,;,ti` / ,�r;;•' ,yr f.• ° /,. '',riles�(�(`S''>',..y1�y!°r`!""+•��i'F jD ✓•,`�."••�`.. '/.,*.,fit .,tl NLATERALSUPPORT ns sPECWlEo 9Y FOUNDATION DRAL4AGE, SYSM11 AS SPECIFIED BY CO,i,S7` ucnON DOCUItt>:M FIGURE 1—TYPICAL SUPERIOR WALL VERTICAL SECTION DETAIL ESR-1662 I Most Widely Accepted and Trusted Page 5 of 5 E>> ' << (EXTERIOR) 13i INCH FACE SHELL FOAM PLASTIC INSULATION 21a BY 7sz INCH CONCRETE STUD,24 INCHES ON CCNTER _GALVANIZED STUD FACING (INTERIOR) FIGURE 2—TYPICAL SUPERIOR WALL HORIZONTAL SECTION DETAIL Ir I I I• - I — j .I FIGURE 3—TYPICAL BEAM POCKET DETAIL ,11 ;loll „1 Iill Illll„I lll;;,:MEN: E ; :;I;II { i^;i „l It Iti; ii;Innu; ""i'i; In it nlll;lill:l" ; :;;:"' 1, II, "o nl;unu. ;;n„ ,n •nu I ,r lu,i;l li.;:. ,;,ui,nil lluai 1;S. l�;l j`j Ina, 1;;,n, n, :,;i1;;;�`�FI; ;i1.."II,1A II ml; 11;i';�;:;;,,;; I:11 I; lii";;I;';11ii 2 :. 1112; i; .1,lul:�::�I'll :ta MIf lu2NitN � D 11;i11' i i::�111 II;,111 It 11 ;:I I;n111 I II I;R;; i;. 1';1;;;;1:;:i ill; i ; ^;;;I;:e'mu N;;ii:;it �;n;;1; n , ,le, I::iiii 1 11 Y;; it II is it:,I;l of�i iinariii;:; iiri ii ni ii;i Ill. a;ii; it:!::: it ;i;ii ii;1;li;li;:1 .Il ii ;;; I;1„ I.„ 11;:�;,ii 1,;11 iI'r it i ,:, ;;.1.i ii;;1, ;;I;i;:1' °:;°is mm al;,It ;::,1;;; y;,a1: iii; ,i1:,;11.;; iii° iiiii iiii ii it it ri ii i;ii;;• ;;i i,II ii^ „1 l; i � 1' 1;;'I:c;'i MI 1::1;11 II; 1i If 1:II; i1 1;it 1;11 U1;;I i;; 1;i41 1; II :1 II 11;: :i II II II111 II 11 II 11,1 :1 I;1,,1111I II 1{I i11111n 11;,11 1 :;i lLL II11 I:1I;;1; 11n11`;n;:11 f y1,1 ',;1 1 , r 1„ i;11;1 I ::�,Il 111 ;; :;"il i� ;1 :;I : ;;;11,,1 i,1;I;:,l I;11, -1111:11i 1:1;:';,I:11;;1 111; 11 I1n 1;II 11 n,1i 11 i11 I1,,I i11 B B ELEVATION ...�..,.�.,...... ILL •Ll L:LLa YL___ --,• ' -i L'•3*L^'LLL:CL= 1 "1 - , Will # t "r, i DETAIL A DETAIL B FIGURE 4—TYPICAL WALL CONNECTION DETAIL I -TM WA TNE X01 LL X-TRA INSULATION PRECAST FOUNDATION Y E DRY ~ ` Your permanent barrier against sidewallwaterpenetration r ® Clean Crushed Stone Footing Shown Auxiliary grain Pipe = I Superior Sealant°Applied in All Joints - — for Permanent Moisture Barrier WARM Warmer in winter,cooler insummer... Y, reduces your home's energy loss Polgisocganurate Insulation i , � _ 0 Sip Covering Rigid Foam Insulation 1"Foam Insulation on Concrete Studs Y i � p f 1"Foam Insulation on Bond Beam '$ 3 SMART '! V,, Ready to finish... l; � Sup2i9fl1�k�� with access built-in Access Holes for Ease in Wiring and Plumbing - 3` � —' -' r!- i ® Galvanized Steel Stud Facing Ready for Orgwall Finishing. CAD Custom-Designed to Virtually Any Home Style ® Laser-Leveled to be Plumb,Level,Square Iw Installs on Your Site in Just Hours for Time and Money Savings SUPERIOR Created in a controlled factorg environment ` . to ensure thatyournewhome's foundation willbe built to the industrys highest standards... 5,000+PSI Concrete for Superior Strength , { 10-114"Overall Wall Thickness Steel Reinforced Top Bond Beam 1-314"Concrete Face Shell Steel Reinforced Concrete Studs t ® Steel Reinforced Footer Beam43 ✓ ' 3 ;�� a Concrete Floor Special Note:Items#1,2&12 as well as " superior Wa��S® the joist/flooring system are provided on site per r Superior Walls specifications by builder and contractors as an integral part of the Superior Walls foundation system. ( __,� -TM X—TRA INSULATION Superior Walls foundations feature patented,insulated,precast concrete wall panels that are formed in a factory-controlled setting and delivered to the new home job site,where 'LF'A0ffwRA the panels are lifted into position with a crane and carefully bolted together and sealed. STRENGTH. The walls are custom-designed and built to virtually any architectural style,complete with window and door openings.Formore information see:www.superiorwalls.com. EXTRAINSULATION. Superior Walls panels are available in a variety of standard heights and custom lengths to suit your project.The maximum axial load[uniform house weight]for this product is 7500 ♦ pounds per linear foot.Special point loads up to 50,000 pounds can be accommodated. Provided with 2-112"Of CaVltg Insulation P- R-12.5 QUALITY ASSURANCE Each manufacturing plant is regularly inspected by an independent third-party inspection ♦ agency to ensure compliance with the Quality Assurance program. In addition, 5000+PSI Concrete reinforced manufacturing and installation personnel are certified by Superior Walls. with rebar and polgpropglene fibers DAMP-PROOFING ♦ Precast access holes for wiring and plumbing The concrete used in the Superior Walls wall systems provides protection against freezelthaw cycles and water vapor transmission.The urethane sealant used between ♦ Thermallg isolatedlinsulated from exterior panels provides superior protection against water penetration.Therefore,no additional damp-proofing materials are required. ♦ Insulated corners,studs and bond beam UAPOR BARRIER ♦ Monolithicallg poured=greater strength No vapor harrier required.Permeance of the Superior Walls panels have been tested in accordance with ASTM E96. ♦ Galvanized steel stud facing FIRE RESISTANCE ♦ Mag be insulated up to R-50+ Superior Walls products indentified in ICC-ES ESH-1662 do not require the attachment of a 15-minute thermal harrier. ♦ No additional damp-proofing required Superior Walls products qualify as a two-hour fire separation wall when two layers of 518"Type drywall are applied to the studs. ♦ Precast openings for windows and doors Superior Walls brand products are manufactured and installed by independently ♦ Reduces building time ownedand operated factories licensedby Superior Walls of America,Ltd. Check with your local Superior Walls representative for availability. ♦ Readg in virtuallg ang weather u erio r: p wallso Su error 3 �oeol s n001 1 e�lx Everg Superior Walls 937 East Earl Road wn superiorwalls.Com New Holland, PA 17557 o ® Tube 800 452-9255 PN312.64 t 4 ry Y� ti 1 11 M 4 _ 1Y • Ir ML dp t ��9 �r ,f � t! •"FI T Y e 1 ham" r .r + � Y 1 on-e.' Closed-cell in 2x6 walls l 0 -of I ; , b , i 5 ?4 • . r \ _i�\ i _� � ' . .�,w� �• ' �� ��� �I �a� .. L IL L r l r =� I n \ l y, • ra�'-'"ice =.z � �- 10 b V1 . /� •�+ LA, • J bed om s I _ 9 J f � 4 i' A 7 . J J�a r`i a 4 &Pi + �'1 ,,•Wit" t + t��•r,Rj i �. ! ; I i ; / y+fir�.• ;'�'v `/ Lt ♦ 4 ♦. � � ti a # i ♦ � f � a • fir' ► ,sy.�. `�_ � � c Attic, C1�i���>�:���-ce.11 spry foam roof insulation ��=' _____ �� --- -- �� . � _ rr .__ _ -�; _ �' �. g, M1 � 1 • �1 _ � � y �.t 'j 1 � �,i � _. :.ae t7' - i f, F ��� I� . _�.. _�., -, ,: _ r � _ . : K ,.., n .�,`� � .. ... . . :.�. �. • ,� �j a �� 4 _ ; r-� �� .,.� � t i _ �- �. - � K .f 7 ' kv lot of r OU 49. �., A�,. ,� ,�y' � ,, �1 \\ �� \ 1 1 ._. _.... '��\ '. --- � : . I 11 1� !- .'1 . � r '1 'r I, 'j r, J ': .� .� .� � , � . _ , , �y � �� , �� .,, � M` �� r� � y ` � , � � � ti ..✓� Verity, Mike From: Z&S Contracting,Inc. <zandscontracting@gmail.com> Sent: Tuesday, March 11, 2025 12:01 PM To: Verity, Mike;Jarski, John; Devlin, Sean Subject: Re: Parsons electrical devices count - Permit# Permit#47742 On Tue, Mar 11, 2025 at 11:54 AM Z&S Contracting,Inc. <zandscontracting@gmail.com>wrote: Hi Sean, Here are the counts you requested for the Parsons house devices. 135 Receptacles 28 GFI Receptacles 108 light switches 22 recessed lights 105 surface mounted lights MAR 1 1 2025 15 under cabinet/toe kick lights 6 ceiling fans 2 bath exhaust fans 1 FanTech remote bath fan unit ( 2nd floor) 5 electric radiant floor heat 25 combo smoke/CO detectors 1 heat detector 4 air handlers and condensers 2 ERV 1 whole house make up air unit 1 Double oven 2 dishwashers 2 disposals 1 refrigerator 1 freezer 1 gas cooktop 1 stove hood 1 ice maker 2 beverage refrigerators 2 Electric dryers 2 washing machines Let me know if you need any other information concerning this. Thanks, Paul 1 r PA a� s r" w j 4� tip' "�' r �? •� .r �ti, �. s ` ! , -; ����' �, �,,. _ ,� ;,.�. '� .r.. H�. � k i ,.. � �l t I..r`a�'�.._` f� ��� '� ` ':}'r t,'�' � t���I�p � �� ;,1. �f1p/ �iw { � Y 'I n ..,_ T,��+l rAj�'l� Y •��{'1�I�1 t ��L }�A4� 5'�'r 4 �i � �.► I �r} Y .if a 1 {a . Ii u .ti .f �i ..+ ,sr . 1/7/25,7:01 AM IMG_8569.jpg Gam' E C E 9 V E J A N - 8 2025 Thread City Building Department Duct & Blower Door Testing Town of Southold ;;4 Pinch St. � t ltamptc,n.CT o6a,.1^ ((M)444-6898 4- 7'hrradcitti•te.tinl;t!+�j;mail.c•onz 2020 Residential Energy Conservation Code of New York Date: December 14. 2024 X Pass X Pass Duct: Fad Blower Door: Fail Street Address: 515 Sterling St .Fishers Island Total Conditioned Floor Area, 6,44Q. Total Duct CFM Loss Allowed: _ 512 _ Total Duct CFM Loss. 251 House Volume 86.364 Total ACH50 Allowed: 4.318 Total Whole House CFM loss: 2.334 Builder: Z&S Contracting 202DRECC -New Construction Post-Construction Duct Test: Total Leakage -- 8 CFM/Duct work in thermal envelope ' Testing Results, 3.93% CFM/t00 ft2 Rough-in Duct Test: Total Leakage--8 CFM/100 ft2 maximum allowed (with equipment) Testing Results. CFMf100 ft2 Blower Door Test Whole House Leakage @ 50 Pascals Testing Results 1.62% ACH50 Signature- Pt Certification # 5063967 EXP 8:2'k25 https://mail.google.comlmaiUu/0!#inbox/WhctKLbVZWBbsmMsfrHJXgRMgIBFhFTctzNtPbBkwvTlrMCvRjxpkXRdZFtGpmjsdgKfxLV?projector=1&mess... 1/1 TOWN OF SOUTHOLD ffQ(&-cOG. y BUILDING DEPARTMENT TOWN CLERK'S OFFICE oy • � � SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50679 Date: 5/15/2024 Permission is hereby granted to: Parsons, J Geddes 4 Palm Trl Hobe Sound, FL 33455 To: demolish an existing dwelling and construct a new single-family dwelling as applied for per DEC Non-Jurisdiction letter, Trustees & SCHD approvals.. replaces by#47742 At premises located at: Sterling St, Fishers Island SCTM # 473889 Sec/Block/Lot# 10.-9-3.1 Pursuant to application dated 3/15/2022 and approved by the Building Inspector. To expire on 11/14/2025. Fees: PERMIT RENEWAL $2,170.25 Total: $2,170.25 Building Inspector �aOF SOUIyO , TOWN OF SOUTHOLD BUILDING DEPT. cou 631-765-1802 'INSPECTION [ ] FOUNDATION 1ST [ZINSULATI R UGH PLBG. [ ] FOUNDATION 2ND [ C ULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: . r DATE INSPECTOR OF SOUTyo� # TOWN OF SOUTHOLD BUILDING DEPT. Comm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ R UGH PLBG. [ ] UNDATION 2ND [ INSULATIO CAULKIN [ FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: - ' s 6v or or 7 ®� DATE ©l �� ''` INSPECTOR -.- OF SOUlyO� * # TOWN OF SOUTHOLD BUILDING DEPT. courme�' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL ] FIREPLACE &CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION LECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: Q 1 DATE INSPECTOR i ' .� ,� �� r �#- ,.., .�r� " d - � ,�� : . � ��' - . r � � �� � � _` R i i� = - .L r:� / 4� � l ♦� � - i a w fi i h i 3 V4 ,Y i . s4 of t i I. i r `' .14 { r f" V �P � c ! n ' f• r f� i`. kr' j �?'.: i ��l /f 4 ` ' J :..; � r i ��i• �, � � �� . �, �, , � � � �._ �, .� __._.�._._. � s �� �_ �; ,, _ — r ' , r 'r 4 4 r �,� � ti�i�� ��� 7r f , i ,,. i �, - .. _ � . .-.x.-.,. _......_ ... ._ ..� �; -- .r.. r^' J 1 t �.� � - 6 - ' ij� }� .� b- � . 1, �� � _. ... SIEGEL J A N 2 6 2024 STRUCTURAL ENGINEERS January 26, 2024 Michael J.Verity Southold Building Department Town Hall Annex Building 54375 Route 25 P.O. Box 1179, Southold, NY 11971 Re: Final Structural Affidavit Parsons Residence Building Permit#47742 Sterling Street, Fishers Island, NY Dear Michael, Siegel Structural Engineers has been retained by ART Architects to perform as the Structural Engineer of Record for the above-referenced project. In this capacity we reviewed architectural plans, performed structural calculations, and produced structural plans, sections, and notes that were previously submitted for Permit. In addition, we visited the project site periodically during construction to confirm compliance with our design and respond to contractor questions. To the best of my knowledge,information and belief, based on limited observation,the structural work generally complies with our design, with the structural provisions of the New York State Building Code for One-and Two-Family Dwellings,and with accepted structural practice. Since our observations were not performed on a full-time basis,there may be non-compliant items about which we cannot attest. Please feel free to contact me with any structural questions about this project. Very truly yours, SIEGEL STRUCTURAL ENGINEERS piFNEPAUt B`k k' a u, o eit�•'' 1 . Steven P. Siegel, P.E., Principal 617.244.1612 1 www.siegelstructural.com 860 Walnut Street,Newton Centre,MA 02459 77��-- _ _ �. :. � i y e. � � _� _ � i �'' � t s ,i�i „�, 1. r t _.. �. �..�.� � , I � iI �-� � 1 -�' _ � ;:� . �� J.y!. i .9 ~ � f VI M +I R :11V AP: WA l a t —T - t EEE ISO I ■ W NONE NOW, NONE . . , ���;�� ` - ry ; �I I� :�= ' ' k a \ � ` Iy t �.1 t 1r`i,,'{ 7' t I y� li t t .� I i I i r `� k �, ; � 'I;� �, j' �' �` �; �' ��� .,� .,�" r., t+ 4 � *, i( � i I fi t � � ►. r �r �s��i � 1 . � a `� ..r � ��.�' i � �j k { !F �" �� �I• � r � I� � � �� 1 �,. �.�'�' a''�' �'";'" sir .� . _ ,� � � �;.' � s. s � � r L a •. P!w �- ,_ :a, ..�' .. �''` w'' .K+f ` �. r �- i.. 4 x��� �, ..� .� ���- �.. .� �. .� �,,� . _ �� ��.- _ ._ .;,�,� i, f ;;';. .; � �, - __ _ -�`-- — - .. — r � � ++ 1` i `4' `t f - I a � �� } �� �'� � � i o ��, ��-i*ei � i �� I � � �i� �' ��7 � 4 r `.�" � � J � �' _ _ .. . � � �- 1 �` �. ./�.. .+ 4h I ;r t � �.-- - - i jf � � ��__� i i E { m � � � �� - �; � , ��. �_� �r'� t� '41�. �� �� � r s ��� � � ��` � � � ,--- � � 1 j � � � � � �{ � , ' � i � t I� -� ,.: �. vow-, i }Y, do* R l t • rr■ ■NE I g ENE y''�� '' e _ .. yl� � _' t<`r�i- � __i � � t _ fir- � _. - ' � -M �, � `��_ _�� e+� __ ,. i � �; L� ` • '� 1 - � i '., � 9 {-�'� �� � ��_ �� �` - ;-+A! A _ T _ / .��. �� � + ��`� �� .' i. s �� ' t t � � t � E �'', ( I �'� ': _ � fl .� '� � f , s"�� 'a 9 ?� a ��` ^� ~� �� r � t• 1' 1 I I I '' - IA A / - Or , , a^ i I _ f M V� 1 r` - A V5 � SOUThOlo —7 -7 L� �\. f # # l BUILDING DEPT TOWN OF SOUTHOLD BU G coum, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: con DATE INSPECTOR 007 790'�-- j 11� ' P J i- f y -��� � 7 r r i�S - 'i'���± 1► .tip ��N++.���T' `~ �� ram` � °5��♦f�•1 " 1�s'� �, ��• -CR i 4 4 t n,y s�7 ?� �r r3�1• �+��,N+ ��5 f •7 M tP ,�_ . f f�a »/ •t 117 . r + 1 N x_ 4� i .1 m i e J'-" t r �q f . 10 ' a p - • T. 00 , r Y fY' 1 y � � ram► Af' of 1 v YL 00 TABLE OF CONTENTS I-- i N V O O N M C5Q R L z ~ 4-11 1J SHEET# SHEET TITLE w _ U w it w 4-4 F- S R S A0.0 COVER • • • C � A1.0 SITE PLAN • A2.0 BASEMENT PLAN • • • Q A2.1 FIRST FLOOR PLAN • • • N G A22 SECOND FLOOR PLAN . • • v d- A2.3 ROOF PLAN • 4-4 • • 0 PERM c AN NORTH&WEST ELEVATIONS • • • rj; .-� Ln 3 22A3.1 SOUTH&EAST ELEVATIONS • • • A4.0 BUILDING SECTIONS • • • A4.1 BUILDING SECTIONS • • • A4.2 PLUMBING RISER DIAGRAM • D AR SO N S S R G S A5.0 WINDOWSCHEDULE • • •� PPROVEQ AS NOTED A5.1 DOOR SCHEDULE � DATE:_ B.P.# �7 7�� RETAIN STORM WATER RUNOFF Cq A6.0 WALL SECTION DETAILS • • N FEE: L Y; PURSUANT TO CHAPTER 236 A6.1 WALL SECTION DETAILS • • NOTIFY' BUILDING DEPARTMENT AT OF THE TOWN CODE. A62 WALL SECTION DETAILS • A7.0 CHIMNEY DETAILS 6 FOLLOWING 8 AM TO 4 PM FOR THE A8.0 INTERIOR ELEVATIONS FIRST FLOOR • �,.�` Hbo� FOLLOWING INSPECTIONS: +` �•'��''�• 1. FOUNDATION - TWO REQUIRED !�t:Ut�llBt�l� ,a• so$ �+� s. FOR POURED CONCRETE p;LL PLUMBING WASTE A8.1 INTERIOR ELEVATIONS FIRST FLOOR • �v1 ••.. . •ti• 2. ROUGH - FRAMING & PLIUMBING '&`WATER LINES NEED,-:"..- A82 INTERIOR ELEVATIONS KITCHEN • %:z :�, '•. ,,,'•t� 3. INSULATION Tt�tN'G E-FORE CO\*-ERIN '''' A8.3 INTERIOR ELEVATIONS SCREENED PORCH • �4 + f�'+ �% .. 4. FINAL - CONSTRUCTION MUST A6,4 INTERIOR ELEVATIONS LIVING AND DINING ROOM `.moo '.p' �oso BE COMPLETE FOR C.O. • • A8.5 INTERIOR ELEVATIONS BEDROOM 117 SUITE • : o si ALL CONSTRUCTION SHALL MEET THE A8.6 INTERIOR ELEVATIONS SECOND FLOOR • �`,��ti ��•b_. ..••••`••s`�.`�' REQUIREMENTS OF THE CODES OF NEW A8.7 INTERIOR ELEVATIONS SECOND FLOOR • YORK STATE. NOT RESPONSIBLE FOR �,�(J,"!2rRCEF3TIFfCt��TI�'�'� A8.8 INTERIOR ELEVATIONS BEDROOM 202 SUITE • A8,9 INTERIOR ELEVATIONS BEDROOM 208 SUITE • DESIGN OR CONSTRUCTION ERRORS. Q;,�LE�i1�CO"„�7EJVT BF�FO"4` A8.10 INTERIOR ELEVATIONS MAIN SUITE • r CERTIFICATE OF OCCUPANCY COMPLY WITH ALL CODES OF SOLDER USED IN N✓ATEFt NEW YORK STATE &, TOWN CODES A8.11 INTERIOR ELEVATIONS MAIN BEDROOM • y F SUPPLY SYSTEM CANNOT A8.12 INTERIOR ELEVATIONS BEDROOM 214 SUITE AS REQUIRED AND CONDITIONSO �/ r E/�Ci�ED�f��Di= �%LEAD. ( A9 0 INTERIOR DETAILS KITCHEN • J A9.1 INTERIOR DETAILS BATHROOMS • I l I v c _ E2.0 BASEMENT ELECTRICAL PLAN • • • Sit?.W 'C1NG BOARD - -I® - T -_T E2.1 FIRST FLOOR ELECTRICAL PLAN • • • �`"'� $GIJTH^vtlu TO'uti'I�TRUS T EES I E2 2 SECOND FLOOR ELECTRICAL PLAN • • • �'� -- _ S0.0 GENERAL NOTES • N.Y.S.BEw = - - _ S1.0 FOUNDATION PLAN • •, -- 1 - S1.1 FIRST FLOOR FRAMING PLAN • - : - SECOND FLOOR FRAMING PLAN • S12 OCCUPANCY OR _ S1.3 ROOF FRAMING PLAN • r of 4 - - S3.1 STRUCTURAL DETAILS • .�. ' USE IS UNLAWFUL = _ - - _ _ S3.2 STRUCTURAL DETAILS r WITHOUT CERTIFICATE- S3,3 STRUCTURAL DETAILS • WI A . - S3.4 STRUCTURAL DETAILS - OF OCCUPANCY : 11 � d r,ire reparation required as per NYS Code VIEW FROM WATER VIEW FROM DOCK 1 2 000 � 1=LECTf< EC�� Must provide Manuals � Its zPE�.CTIOII REOUIRIED D, J and S as per NYS Energy Code m J J W W W TnUSS IPLAQARDIMG r.EQ UIRED All exterior lighting A installed,replaced or .�• all conform NOT PROCEED WITH repaired shall ter 172 z FRAIONO UNTIL SURVEX,, to ChapU Elf OF FOUNDATION LOCATIION of the Town Code 11A5 BEEN APPROVED). 7-4 v N N r l�loti�cr door ,and ductvlOrk e-�- de- testing '6 04f o erg. � required re � � , I - p _ 3 a - .. _ a - _ - - -... .. URI _. - - - - - _. - - --- - - _ - - - _ - - - - O _ : - - -- - - - - - - -- - - _- - --- - ) � � � � � � ri MAR 15 2022 31 VIEW FROM NW FROM SW VIEW FROM STERLING ST g�►�DI���oE�T • 4YITOWN of sourfIoL D v STRAW BALE BINDER /I -� PLASTIC LINING MARE / Drawing Copyright®2015 NATIVE MATERIAL PROVIDE� �CAST�) TEST HOLE DATA (OPTIONAL) O� f / 4• KET PIPE BY: RH STROUSE P.E.L.S. DATE: 04-22-2021SECTION 8- \ - C .mow WOOD OR NOT TO SCALE 20" N SDR-35 O 1%(MIN) O"- 12" TOPSOIL \ WEST SD• METAL STAKES 12"- 26" SANDY SUBSOIL 1 (2 PER BALE) ° ° 40"- 204" WELL GRADED COURSE SAND-FEW FINES-SW HARBOR 101 East River Drive,1st Floor ° -- --- ------ - EXPECTED GROUND WATER ELEVATION- BELOW ELEVATION 7 East Hartford,CT 06108 I / 860-885-10551 www.chacompanies.com 'Q� QGi 4' PIPE TO •�•1 o' MIN. NEXT GALLEY ° ®® .--\ ® � e B I ®® ��� ®® ° SOIL CLASSIFICATIONS ( / R E-Riverhead and Plymouth very boulde soils- 15-30% slopes 6 ( ®®® ®® 0 1 o P Y rY rY FIBIk VARIES R FgeRl CONSTRUCTION ENTRANCE NOT TO SCALE - I ° ®®® 7®10 ®® 1 ( SITE 0 ^ \ NOTES: PLASTIC STRAW BALE I LINING PLAN (TYP) 1. REMOVE TOPSOIL AN ORGANICS PRIOR TO PLACEMENT OF CRUSHED STONE. NOT TO SCALE I 8'-6" I I 2. ENTRANCE SHALL BE 12' WIDE MINIMUM. ctxLnLaTF tLrws±nlr prr 3. SUB-BASE OF FREE DRAIN COARSE SAND-QUVEL (SW) DRAINING BACKFILL MAY BE USED IN LIEU OF 1z GEOTEXTILE FILTER FABRIC. NOTES- RED \ 4. MAINTAIN BY TOP DRESSING WITH ADDITIONAL SPONE AND REPAIRING RUTS 1. DIMENSIONS SHOWN ARE FOR TYPICAL RESIDENTIAL CONCRETE AS REQUIRED. ADDITIONAL LENGTH MAY BE REQUIRED IF SEDIMENT IS PUMPS MUSTT BE SIZED ACCORDINGLY(7CTION. LARGER PROJECTS OR RGALL S/TRUCK,OJECTS G LEACHING GALLEY GROUNDWATER TRACKED ONTO PAVED AREAS. ANY SEDIMENT SPILIIED, DROPPED OR TRACKED ONTO PAVED SURFACES SHALL BE REMOVED IMMEDIATELY. 50 GALLONS/PUMP, Plus MIN. 1' FREEBOARD). 4'-9"X8'-6"X4'-6-1/2- DRILL 2. CAPTURE MATERIAL AND LIQUIDS MUST BE REMOVED FROM NOT TO SCALE COASTAL EROSION HOLEPIT AND PROPERLY 75%OF ITS CAPACITY DISPOSED OF � THE PIT REACHES HAZARD LINE �`r r^ < / 3. INSPECT PIT PRIOR TO EACH USE TO ENSURE CONTAINMENT � + SITE PLAN OF WASH WATER. �, \ s1r. �O lippV� � o PREPARED FOR: ELIZABETH PEISHOFF LIMITS OF FLOOD ZONE VE g0��• \GONG ETE O \� N/F FROM FIRM MAP 3610300019H fk� �� \ CAPEXISTING �`' q J. GEDDES PARSONS SINGLE FAMILY RESIDENCE CHARLES W. GREENLEAF SEPTEMBER 25, 2009 a ham' °� ? '�tiG 515 STERLING STREET 'VACANT LAND" \ MUNICIPAL WATER ���� �� `} F FISHERS ISLAND, NY \ ON SITE SEPTIC SYSTEM (2 CHAMBERS) N 6°�54 � ` '\� \ \ \� \' EXISTING � PROVIDE \ \\ \ SEA WALL LOCATION MAP SCALE 1 =400 z N p? � SILT FENCE \� \ -MAINTAIN MAINTAIN DURING SIN 67'34'00 E3.34' 30. E 46��� CONSTRUCTI 105 Ste\ S 6541'00" E 14 PROVIDE4 81'06 ` I \ \ \ POLE FLAG �� 35.00 ' \ \ � \ � �� �� NOTES LEACHING CHAMBERS \ \ STOCKPILE - \ \ _ ow TRAIL \ (SEE DETAIL) \��, \ AREA \ \ ,� BENCH MARK 1.) THIS SURVEY WAS PREPARED FOR THE PARTIES AND PURPOSE INDICATED _ bWE AREA TO 59K \ �� \ HEREON. ANY EXTENSION OF THE USE BEYOND THE PURPOSED AGREED TO PROVIDE T \ \� io i�'� \ "' � BETWEEN THE CLIENT AND THE SURVEYOR EXCEEDS THE SCOPE OF THE DISTRIBUTION � � � ENGAGEMENT. BOX (SEE DETAIL) � r' o 'd' ,'sro PROVIDE DRY WELLS FOR ROOF DRAINAGE)-3 RAINAGE 2.) IT IS A VIOLATION OF THE STATE EDUCA11ON LAW FOR ANY PERSON, / �r� \ PROVIDE 1500 GAL \ \ l O �\ \ (OR ROOF DRY WELLS) UNLESS ACTING UNDER THE DIRECTION OF A LICENSED LAND SURVEYOR, TO ASEPTIC TANK (SEE DETAIL) \ l - . ALTER AN ITEM IN ANY WAY. _ o, (SEE DETAIL) N/F // / -� 4�-�. ,« \ \ \\ O v ' \ \.^j opt 3.) ONLY COPIES OF THIS SURVEY MARKED WITH THE LAND SURVEYOR'S MONTAUK LLC / / SUBJECT TO RIGHTS ACROSS "RESTRICTED LAND" \ �',� \ v \� SIGNATURE AND AN ORIGINAL EMBOSSED OR INK SEAL ARE THE PRODUCT OF SINGLE FAMILY /� / y'�-- AS NOTED IN LIBER 8367 PAGE 58 >: �� PROPOSED-2 STORY� THE LAND SURVEYOR. RESIDENCE -� ° - ''� y 5 BEDROOM RESIDENCE � IN ORDER TO PRESERVE WATER VIEWS \ �a � . /�\ Lv FOR ABUTTING PROPERTY ` \ \ \-� �� (FF-22.7) WITH ATTACHED MUNICIPAL WATER / `\�s\ V . �'� ����\� \\ H�saDE; �26\ X \ ' GARAGE (FF-21.33) AND 4.) COORDINATE DISTANCES ARE MEASURED FROM U.S. COAST AND GEODETIC 2x2 5/s 1s GA. ON SITE SEPTIC SYSTEM / / %� �\\ �'l c o \�� �� ° \o / UNFINISHED BASEMENT SURVEY TRIANGULATION STATION "PROS" L \ (FF-14.16) WIRE MESH `•� / 1/j 0//IAI\\\ 1 1 \�-`� \ \ ----� / I 5.) SITE IS IN THE TOWN OF SOUTHOLD, COUNTY OF SUFFOLK TAX MAP 1000 t 1/2' / / (0. ., \ O 10, PORTION OF SECTION 010, BLOCK 9, LOT 3.1 / / ( 0v CENTER OF 10' 1 \ 1 STERLING STREET M �^ / / WIDE WATER LINE a I o ".� 1 DISCONTINUED BY 6.) TOTAL AREA = 1.90t ACRES. N exlsnNc �j�`� / ��-� RIGHT OF WAY \ I �6• ( THE TOWN JULY 9, 1963 RESIDENCEprO' - `L LINE NOT IN \\ /P2o17 DRILL / �1 7.) SITE IS LOCATED IN R-40 ZONE. SERVICE PER / I ��`��` HOLE . ( 36 PROVIDE NEW WATER SERVICE- �, ( � FI WATER WORKS �\ I COORDINATE W/Fl WATER WORKS 8.) BASE FOR LEVELS: NAVD88 C \ n I / / // ° ) ` CENTER OF \ I / REMOVE EXISTING N IT Is A VIMATM OF LAW FOR ANY PERSON,UNLESS ICY ARE '} RESIDENCE. PUMP EXISTING 9.) PERCENT OF LOT COVERAGE PROPOSED- 5.2% 1 D WIDE a+ // ) M .• ACTING tRDFft THE dRECnoN OF A LxsED PROFEssIDNa POLE LINE / `� ° % ^ O ETiGMEER ARMIECT LANDSCAPE ARCHrM=OR LAND Tp SEPTIC SYSTEM-ALL suRvfYOR To ALTER AH CT MANY MAY. AN nE1t eEARn+G tNE 2" 2•I- / / i/ v RIGHT OF / < ( .% ' o MATERIAL TO BE REMOVED 10.) THERE ARE NO DOMESTIC WELLS WITH 150 FEET OF THE PROPOSED STAMP OF A LxaE M PROFESSIONAL IS ALTERED,THE AL70 MG \ 1 N o w `- DEVELOPMENT. EHGINEIIt,ARCHITECT,LANDSCAPE ARCMTECT OR LAND ' \ \ WAY l , 13 I y� FROM SITE-(PROVIDE FORM WWM-080) NSIAZY •ALTERED TY'F THE D D Err TIER sIHMUDE THE L w� ` / SURVEYOR SHALL STAMP THE DOgA1Q1T AND euxLIDE THE STANDARDTTO SCALE B� ExlsnNc ` \ \ \ \ \ 6`•ti� /� N N I I I\ �- \���� // / PROVIDE N/F DATE of SUCH ALTERATION,�TM cFTc oEsanPnon GARAGE " �' ��'f^4� / �\ /'`IV CONSTRUCTION ENTRANCE TION THOMAS J. SHILLO PROVIDE SYSTEM OU DESIGN BASEMENT-5 RNEpR0OM RESIDENCE h /' o r' SINGLE FAMILY RESIDENCE E T PROVIDE 4 C.I. PIPE TO SEPTIC TANK. SUBJECT TO RIGHTS ACROSS RESTRICTED LAND \ C7 r'sr \ �\ o (SEE DETAIL) MUNICIPAL WATER PROVIDE 1500 GALLON SEPTIC TANK- INLET INVERT = 20.0 AS NOTED IN LIBER 8367 PAGE 58 \ � � I ` �� w OUTLET INVERT= 19.75 / IN ORDER TO PRESERVE WATER VIEWS \ \ CENTER OF I I r, I ► ON SITE SEPTIC SYSTEM PROVIDE 1 DISTRIBUTION BOX- INLET ELEVATION-19.5 168 9g FOR ABUTTING PROPERTY \ POLE LINE o XIISTING 1 POLE PROVIDE 2 ROWS OF LEACHING GALLEYS SEE DETAIL INLET ELEVA-nONS= 19.0 SILT FENCE ' RIGHT OF WAY V �\_ 1 MON. i� ( )- v LEACHING REQUIRED-400 SO. FT.- PROVIDED- 424 SQ. FT. N �•14,5�" \ 4 , \ I � GRAVEL (BURIED) 1 N 1582.94 W 6 \ PAIRKING 1 CONNECT ROWS OF CHAMBERS AS SHOWN WOVEN V111RE FENCE (MIN. 14 \ ' ' I I �) Y W 152.66 USE CHAMBERS MANUFACTURED BY DIAMOND PRECAST PRODUCTS GAUGE W/ MAX. 6" MESH �48 I S 05'01 41 W EXISTING SEPTIC SYSTEM TO BE LOCATED, PUMPED AND SPACING) \ \ \ ° I ' ' / i^`� 1 11.31• REMOVED. PROVIDE FORM WWM-080 1� 10' MAX. CENTER TO CENTER 36" MIN. LENGTH F N6E s \ ' *� (I rry r��, INTO GROUND \ I 1 PARCEL ACQUIRED BY ` \ I \ \ 1 13 J. GEDDES PARSONS �.... r.,> 1 s 25•01 15 INLIBER D0001 J 1 J 1 PAGE 651 `u it N F \ I I I I \ 1 21.52 11-29-2021 / I I I I I '�/ O/ JAMES & JEANNIE BALLENTINE LIMITS OF , ti PROVIDE I y SINGLE FAMILY RESIDENCE z 3 DISTURBANCE STAGING \ �` ~ ,\ WASHOUT ONCRETE �. /\� HEIGHT OF MUNICIPAL WATER o 0 28,000t S.F. ( ,� `,a ►�o Q FILTER = 16" MIN. ON SITE SEPTIC SYSTEM 0 EASEMENT AREA FOR \ \ SEE DETAIL 10 -8 �•.. �, . •H / PARKING- AREAS \ KNOCKOUT INLET AND W//� EMBED FILTER SHED 1,384t SO. FT. OUTLET OPENINGS / s � �9 CLOTH A MIN. OF y "DRY" BUILDING 6• 3 6" IN GROUND o\ it V N 1510.69 RIBS INSIDE PERSPECTIVE VIEW s 25•o1'ii oo ifh' `� Do IRON N �� � �a + PIPE /� / U) WOVEN WIRE FENCE (MIN. 14 II 160.569 ��=c��/ &CO* No. Submittal I Revision App'd By Date 1/2 GAUGE W/ MAX. 6" MESH-C Q ? 1 RHS 08/12/2021 SPACING) WITH FILTER CLOTH IRON / �' ' ONCRETE CHAMBER Z PROPOSED ROOF LEADER PIPE S 84 3f-5 W o/ RESIDENCE (POUND) DETAIL 36" MIN. FENCE POST to N/F / / % % CAST J 2 BOUNDARY UP-DATE RHS 02/11/2022 UNDISTURBED ROBERTA C. ELWELL /° i i CONCRETE COVERS / o FLOW-� I GROUND \ ovEPRF"oLo"w"E SINGLE FAMILY RESIDENCE ;/ f/ PLAN 3 HOUSE FOOTPRINT RHS 03/10/2022 % Z 4' PVC CUT MUNICIPAL WATER r` COMPACTED SOIL-�-� \\ ON SITE SEPTIC SYSTEM / / COVER LOCKING CASTING N �\ TO LENGTH MIN. 6' SOIL COVER / /s' \ EMBED FILTER CLOTH \��\\�\\�\\� io o COVER DRYWELL BLOCKS AND CATCH / / r TO GRADE TO GRADE �O A MIN. OF 6" IN GROUND \'� �/ BASIN GRATE TO GRADE / / / IF DROP 'T' 4" FILTER FABRIC f (NEENAH R-2525-F) OR EQUAL o / / IS USED FINISHED GRADE CHIMNEY z WIRE MESH �- �.T10N VIEW 90•BEND m o m / N Q 20" 20" EGEND PROPERTY LINE D_ m @ ® ® m min. m n. 4, w CONSTRUCo TION SPECIFICATIONS SLOPE AS REQUIRED o m ® o o INLET ---- �' EDGE OF PAVEMENT ERS LINE O O O ® m ;� 4" VENT a 4' VENT OUTLET F- 1' STONE OR p O O @ O , LEVEL--' SCREENED GRAVEL - LIQUID LEVEL ; 4.. OUTLET / EDGE OF GRAVEL c� 1. WOVEN WIRE FENCE TO BE FASTENED SECURELY TO FENCE POSTS WITH WIRE ___ Z TIES OR STAPLES, POSTS SHALL BE STEEL EITHER "T"' OR "U" TYPE OR 1' 8' 1' CONTINUOUS HOT BAFFLE EXISTING CONTOUR --- 12 w HARDWOOD. STORMWATER DRYWELL DETAIL 10' ASPHALT SEAL /$DWITH PROPOSED CONTOUR r.� PROPORESIDENCE BEDROOM v~) 2. FILTER CLOTH TO BE FASTENED SECURELY TO WOVEN WIRE FENCE WITH TIES NOT To SCALE \-Th, so• EC STONE WALL DEFLECTOR N SPACED EVERY 24" AT TOP AND MID SECTION, FENCE SHALL BE WOVEN WIRE, DRAINAGE CALCULATIONS RETAINING WALL ^ � 6" MAXIMUM MESH OPENING. ROOF AREA = 3 664 SF % -�" " FENCE TREE LINE 0 3. WHEN TWO SECTIONS OF FILTER CLOTH ADJOIN EACH OTHER THEY SHALL BE 3 CROSS SECTION 3" Designed By: Drawn By: Checked By: :-WER-LAPPED BY SIX INCHES AND FOLDED, FILTER CLOTH SHALL BE EITHER OVERHEAD WIRES O/W o r1LTER X, MIRAFI 10OX, STABILNKA T140N, OR APPROVED EQUIVALENT. REQUIRED = 3,664 SF SF X 2/12 = 611 CF I AM FAMILIAR WITH THE STANDARDS FOR APPROVAL NOW OR FORMERLY N F RHS RAC RHS PREFABRICATED UNITS SHALL BE GEOFAB, ENVIROFENCE, OR APPROVED DRY WELLS AND CONSTRUCTION OF SUBSURFACE SEWAGE UTILITY POLE -/+- Issue Date: Project No: Scale: N c QUIVALENT. 611 CF /28.27 CF/VF = 21.6 VF DISPOSAL SYSTEMS FOR SINGLE FAMILY RESIDENCE BOUNDARY POINT ® 06-08-2021 069627 V,=30' o USE FOUR(4) - 6'0 X 6'- DEEP DRY WELLS. AND WILL ABIDE BY THE CONDITIONS SET FORTfH 1500 GALLON 5. MAINTENANCE SHALL BE PERFORMED AS NEEDED AND MATERIAL REMOVED WHEN ( ) it "BULGES" DEVELOP IN THE SILT FENCE. THEREIN AND ON THE PERMIT TO CONSTRUCT. 2 COMPARTMENT Drawing NO.: iSOIL CLASSIFICATIONS SEPTIC TANK APPLICANT NOT TO SCALE 30 15 0 30 RpE-Riverhead and Plymouth very bouldery soils- 15-30% slopes GRAPHIC SCALE: IN FEET SHEET 1 OF 1 12'-0314" 4 L31 t- T-11" 26'-11 1/2" r L 1 '-51/2" 10 EQ.3 EQ. 3id UP M W -------------- -- -------------- -- ----------------- U T 1 1 —�- - -�--- - - r i J L J L J L J L +'� J L J L J L L J W 2 DECK ABOVELo v Lo PORCH ABOVE DECK ABOVE 22'-01/2" - 11'-111/4" I 4 34'-7' i 17-11 1/2' I- _g" U l 1 1 I 2 i 3 i 5 1 I o L � w •-; J f— I �l 101 I01 c A4.1 1 Lo L — J L J ; Lo �. ' 1'-6" I Nc rsool L I I M, up �2' g,' r•Vf ak�V"Q C�" � F RAISED HEARTH ABOVE BASEMENT-STiORAGE I & MECHANICAL F -L- -1 I F � —I F4- -I I I 1 (— � -1 F -I- -1 HWH BOILER ---- -________________ __�=-�__�_--_=_== -- - - -_ --__ ==z== =I =_ -===_=_ �_ -�- =_ -__ =_�=_ =_ =__=_==_ -_=�===_==_=_=__�= _+_-----I- L � J Ij L � J LtJ I I 1J L fi J N BEAM ABOVE � - - - � STEEL LALLY 1 r�-1 COLUMNS(TYP.) RAISED HEARTH ABOVE I I I L - - - - - - L4 W I r ^ n 3T-0" J. 39-31/2" 5'-10" 9'L2" — — — — -101/4" z 10 T-41/2" CC BEAM ABOVE ( —�— O _ I I (- —I— --II -1 --------- -------------- L — - - — - — - - -Ifi-- --fi------------t== '-- ------------ �- -1--------- - III — � —I— J L —I— J L ILJ III � � III N cy I I I I 1 A4.1 III i i 5'-10" I I � I I I I I Wuj III � I I w w III I I I I I I I BEAM ABOVE ; ; PORCH 1 ' M C! -I- -------------- ABOVE L _i J N - -f �- ----- -- 0 2 - - _ - " L _ _-- - I iv c i�i L -I_ J ~ II UP I i i c i I EQ EQ i i I (,� o 0 0 0 0 ELEC.PANEL i i i W V I I I � I I WWW w w w w w A4.1 I I A I I 3 Lh I I 1 I � I I w w I I I I > > cr LIJ ? � I I H � Of 0- d LW O N N N N O\ y N N A \ � N O � �t � O CD I CO M W II A4.1 4 z V � Q UNEXCAVATED n CN CN �-- z W W U z H m FL . .' ANA200 BUII_DINh DEP7 3T-0" 32'-0" 5'-10" 9'-2" IrA4.0 if 3 AJ.0S -- - -- - ------------------------- I , I , I 1 Vl 1 — — — — — — — — — — — — — -m DN i o0 I I II I II ; N W E 1 � v 4 A8.3 2 I 0 1 113 2 3 ° A4.0 EAST11 ID 1 ECK WEST DECK SCREENED PORC Ln I I A4.1 q wJ(4c^- - I - ------------------I ----- - --- - 1I II 1094449, ,4'y'� MfCA DN I A A F A� 102 --------- ---7 ---F,rIILrI---_-1i-2_-I1IIIiIIii1III1iIIIIIIIIIIIIIIIIIIII1IIIIII 0�+It I1IIIIIIII-II�I1IIIIIIIII1IIIiIIIIIii1IIII�IIIIIIIIII —_—L1IIII1uII1I1II�IFrI1LIIII1 IIIIII1IIII11I1IIIIIIIIIIiIIII0 3_-_-8-_-_IrIIIIIIIIIIIIIIIIIIIIIIiI IIIIII D—o-W ,'—I — —IIIIIiII1I1IIIIIIIIII11IIIIIIIIIIIII I1iIIIIIII�IIIIIIIIIIII iII1IIIII1IIIIIIIII�II11IIIIII JI _ - -,,,,II1I;�II;I,,,,II'I,IiIIIIIIIIII 10-IIIII11II1,II1II�I1I1III1iIIIIII -=I,t,1,IIiIIIIIIIII1_IIIIIIII III--��_V--1,IIiIIIIIIIIII—IIII1iIIIIIIII ---,-�'1--:--- ,�lIIII1I I1 iIIIIIIIIIIIIIIII1III-IIII1 11I ---_-- A8.2 TRAY CEILING 1 10 ITCHEN A8.41 2 23 31 I 11d TV II I WOOD ; BEDROOM IMICR0. O CUBBY ABOVE ob j WOOD ---- --------------- ---- O1I 8 AB.2 N TV ABOVE - 11,11 DW 12a OVE�SI13 4 2 F 16 A8.5 14 1 5 I ---------j 15 a A8. s E I I cj� BATH CL7 115 A 82 5 WOOD 1 A8.5 D TILE 124 o — — — --- " ID€BOARD ICE WINE STORAGE----- -----BAR- - IIAKE REF. -y- 2 L----------------------------------------- ALCOVE .O. 1,II1,iI,I1,IIIIIIIII1II1I II ,II a^,b�'f�+�rJ���{o o�•Ik`Da/�S�•sO>'R� d `,��`�-�►.y;Y.,4>:x.':{: +��`*p""p�.er�«+•� y am C_w 1 AaWrW~(CIxV�WWAA►✓�-r n�•1di ` Nw WrNn=wT- 1WO���1VWN<_w�j t'{ PvW1HFH--�r4 A4.1 R A3.12 ENTRYP 9 A8.1 s 8 WOOD ANT I EQ EQ ENT CH _U 19WOOD 8 A8. 6WDR R7 4 2 STONE WALKWAY V m 0 m 0 0 3 W OD -3 MUD OOM 0 4 -- A4.1 2 A8.6 4 TIE mz IF LAUNDRY 13A8.0 11 103 12 TILE w> � � f-- CD CD cD N r) ------------------------- ------- --------------T ------------------------A4.1 STORAGE GARAGEt__J 104 CD(I T— --I--------------------- L-� 1.--J I ----------------- - - -- -1-=_ 105 —11L 0 � � — — -�,iII1^ I— • 1 A4.0 A4.0 A4.0 A4.0 1 2 5 :F— 01- Ll _ J 0 E ' I �-- v — >~ _ - o MAIN BEDROOM I m = v .y u TV ; � ; 210 WOOD w I ' � I 1 g i 10 I I r O i i 13 A8.10 11 i ' czi ( 4. tn I I , I I I I G I I � I I I SHEL VE 22 I I .e'� Hco", w SHELVES SHELVES q� - - - - - - HALL I `v I MAIN (BATH 209 5 MAIN CLOSET LL- ----FLATC -NG ---- 1 1 218 8 A8.10 6 209A FLATC -G------ TV SLOPED CEILING 6 A8.11 2 7 ----------------- ------ ---------- TILLIE WOOD 1 WOOD ------N--- -----------------4 SLOPED CEILING 1 4 4 A8.10 2 ---- STAGGERED BEDROOM STUD WALL / 22 2 3 214 I A8.11 7 LIN 13 BEDROOM 5 10 A8.11 8 CLOS T 16 A8.9 14 WOOD 9 \� 9 n ,CC O E 5 15 208 1 12 A8.12 10 U / ,�'� J.�/ I I 11 216 20 A 8 A8.9 1 / WOOD STAGGERED D 7 f -� - - - - - - - - — -STUD WALLL- - - 212 1 , / I W00s -' I i 4 A8.12 2 :C22' , S WINDOW 3 21 ABOVE W I 22 0 I I CLO i — _ _ HALL 1 �j I I 21 ; 1s 0 HALL 211 06 4 A8.9 2 1 ❑ I F�� 3 ^ ---- ---- ------- ------- ---- ----- 5 p I i 20A8.12 18 I 205 OOD n + SLOP CEILING ------ ---- ---------------- rn T i--i --- 8 A8.112 6 i 19 I WOOD SLOPED CEILING 7 BATH 10 210CL 213 I_ I vJ TILE W ; 7 BATH I ® I.._.� I o I 0 8 A8.7 6 1 I r ^ - - - - - - - - - - - - - - - - - - - - - - - - - � — w l I 207 - - - - o i 14 O I TILE r - o I f i 17 A8.0 F-----� �i - - - - - 71 PULL- i -I _ DOWN 1 3 ° i STAIR 9 w ' ABOVE 2 A 1 8.121 i I A8.9 10 2 I 15 -----J 11 P.4 1J CL I H 209 STAIR HALL I I OD I r ^ I ; WOOD L�;RY DN 204 1 I 1 J ' TILE 4 A8.7 2 — A c� I p 3 I 1 a I V o 0 0 0 0 CL w - - - - - -D L V 1 207 � 1 I I 2 A8.6 4 201 I m w w w w ' � I 1 BAH I W z Z 4 A8.8 2 0 203 9 I w g 1 13 A8.8 10 Of of w w w 2 6 HA L 3 ILE 11 - J 0-1 a o- 201 — — — — — WOOD L i 203 I � i I I GUTTERS Q N M O STAGGERED STUD WALL 1 wl I 1 U I I cop l I r O 1 U" � � I a -n 1 Tv I c ; BEDROOM 5 ; 0 I z Imo— M W A4.1 I ; i 202 8 A8.8 6 i Z I J II 4 (D ; i WOOD 7 i I n \ 1 ' i , I u - - - - — I- - - - - - - - - - - - ir OJ I I CD 1 I I Icf) O I I I I I I ` I N i Q I I I L-- - - - --- - - - - - - - - - - - - - - - - - - i - - - - - - - - - - - - - - - --� • O A4.0 A4.0 A4.0 N SLOPE - - - - � - - - - - - - - - - - - - - - - - - LU '� SLOPE I SLOPE —�—► _ `y,+, llitia pP� ct r w SLOPE SLOPE I •, ••�aE • I EXTERIOR EDGE OF FRAMING BELOW cu Z-77 A4.1 I I _ J I c 4 r= I I I SLOPE S PE I I I - - - I I I I f I I I I I I I I SLOPE I f I f I I I I I SLOPE I I SLOPE I I I I I I T SLOPE I SLOPE SLOPE I I I I I SLOPE ❑ I I i I I ❑ I SLOPE I SLOPE SLOPE I i ❑ I ., l I - - - - - - - - - - - - - - - - - - - - - - - - _ - - - _ - - - _ - - - - _ - - - - - - - SLOPE I O SLOPE SLOPE SLOPE ^ H I I v, - - - - - - J - - - - - - - - - - - - - - - - - - - JPE I- - - - - - - - - - - - - - - - - L - - - - - - P0,04 I I I A4.1 I I I I GUTTER w I I (SLOPE --►- I I I SLOPE V J !L I I I I I I — SLOPE SLOPE I I I I I J I F _ _ I I I (SLOPE i I m J J W W W A4.1 w CD I I I o SLOPE: SLOPE i I N � I I I r— — — SLOPE A4.1 4 I I ❑ I I I I z CCU CD SLOPE( I I I I I L — — — — — — — — — — — — — — — — — — — — J I I SLOPE I I 93 W or. '2 w E STONE STONE VENEER VENEER z u u 4- 6 Vi ell, O d d r%vool, SECOND FL SUlBFL/4�23 d d d 91 BID 1L.1 I AII ;J FIRST FL SUlBFL STONE NEER� VENEER O )R3 !Z4 00 'ILL PT ------- CIOO I� T.O. SLAB 1/4"= -01111 P� Q � � � � W w s l� , a� STONE 3 VENEER u <c -zic m 0 V w Uj w L'i w o FLASHING 0 ci !7 Bo LLJ LLL \1 LL� C� CD Ll cn 5� u ol- u Of C? A6.0 W w L�j L'i af [if 3 I a- a- SECOND FL SUBFL CN 3 3 -3/-4 CN CN r-_ — — — — — — — — — -- ci ci CD I 0 0 Ll Lill I c— bo I z10 U FIRST FL SUBBFL r —2�2 8 STONE VENEER I'l-) cr- LLJ L ul�L C) al -,00- 2 WEST ELEVATION 1/4"= V-0" 00 � G 4-1 N � C W o L J - ,, V STONE v VENEER STONE _ y VENEER U ccz .............................................................. �Q•` frb04 •r� f�, ................ ..... ............................................................... ................................................................ .................."......................."............ ..............................--..................... ' ..................................................................... r ............ ................ ............ .... ...................... ... .................................... ct ............................................... N SECOND FL SUBFL — — — — — — — — — — — — — — — — — — — — — — — — — ........................ 33' -2 3/411 .. ... ........ . ..... .. .................................................. ....................... Lj� ................ ...................... ................................. ................... i is ! is _............ ............................._..... .... ... ..... .." .. ."... is is ......................................................................................................................."."............................................................................................................................................................................................................................................................................................................................................. ...... ...... ............................................................ ........................................... is FIRST FL SUBFL 41 SOUTH ELEVATION T.O. GA F--� 1/4"= 1'-0" r /1 Q,5 V J ~ W STONE VENEER r�T W ..................................................................................................................."..................................... ........................"".."."..""........................................................"".... .."..".............................................. .......................................................................................................................................................... ..................... ...... ....... i i ............. i Mart .. ......................... ......."".. .............".-...................... .............. .. . w w ................................................................................................................................ SECOND FL SUBF w w z 33' -2 3/4" ................................................................................................. ........"... .............. .... .... .... y: ............................................................... ...... .......... . :. 0 CD i O...... ....... LJ ..... ........... .... .. ........... ...... i..%. ........ ......... ................. ...... ..........""...."..........................................--- .-------- Li .... . . FIR T FL UBFL ............................................................................................ — — .. 22 8 .0. FND. WALL -TYPICAL I - L7 13 EAST ELEVATION ` O11-011 as { • A4.1 A4.1 `�'� O 00 A4.1 A4.1 .���a.,►i►►4� N 1 Q 12 7 u 4-4 3--1 ::::: -� ::..;;:::< ; ; : ;;: . ,,,:: . ;. ,. ,.; <; ;;,,;;; ;,; B.O. CEILING 2N D FL BEDRMS 43 -4 7/8 Q N >, � n BEDROOM 12 214 \ \ 0 rc A6.0 A6.0 ; FL BFL ..........:..:. SECOND SU .... .... .... ..... ..... ..... ........ .... ............ . ... .::::. .. . .. 3 2 3/4 .:..::.:........... .::. : : . ... .... ..... T.O. PLATE =BEDROOM 11 — — — — — — � 31 -4 f I BEDROOM BATH ' � C LIVING DINING R OM 116 117 , III I is 114 0 i i fill 1 11 .:.:.:....... .... ... . . FIRST FL io SUBF22 L I FIRST FL SUBFL r `, I �T.O. FND. WALL-TYPICAL T.O. FND. WT4 ALL -TYPICAL I `' 21' -81/2" 21' -8 1/2" ]IT T.O. SLAB 141 -211 _ I _ :- T.O. FOOTING _ _ T 0 SLAB L - — - — - - 13' - 10" � � T.O. FOOTING r ^ � I V J ~ SECTION A SECTION B - - - — - — 13' - 10" 11/4 1 0 2 1/4 - 1-011 A4.1 �Ml 2 3 2 1 12 %' A6.1 7 3 f B. . - 0 CEILING 2ND FL BEDRM S : 43 4 7/8 :. I 0 0 0 0 . ..... ..::.:.. : 1 f 1 Q Li ' BAH [AIR HALL 213 200 26 BEDROOM .: L_ L L�j \ 12 1J7: ;:: ; SECOND FL SUBFL 7 ; ......... ....... T.O. PLATE - KITCHEN o >? to N � I r: Yell i` 01 KITCHEN -AST DEC Fill I /..: 1 C r � V 1 I z _ o \ rift FIRST FL SUBFL o❑ ■ f-- : ............. . ........... . .. ............. ............ . ..:.. ........... ... .................... 2 C� : . ........... ... .... ...... ... 41 r.. 2 811 �A. ............ .. F.. ;; CD T.O. FND. WALL-TYPIC '"" ' CN 21 -8 1/2 .. T.O. SLAB T.O. FOOTING 13' - 10" SECTION C SECTION D 1/4"= 1'-0" 1/4" = 1'-0" e 00 N U A4.0 A4.0 A4.0 A4.0 ' f 5 3 3 5 W F' O /:..,. ♦ D • N s vi s• cn 0 w a 12 w 1 , 12 TT Y at (p M " !1 :r 0 � p �O w a B.O. CEILING 2ND FL BEDRMS l w 4 / _ �43 7 8 J a �v w N; 1 T-.O.�fi�LARGE DORMERS — — — — r- - _ v � 40' -8 3/4" rf •-� T.O. PLATE SMAL DORMERS -------:z::_::r.:'- I 12I T.O. PLA E -SMALL DORMERS � � 4l' -4 3/4" 41' -4 3/4" p co '-- tn 26 .:..... MAIN BEDROOM L AT EEL1 r 210 As.2 0 A SECOND FL SUBFL 06 5 N 12 33 -2 3/4 L SUBFL 4 f/2 SECOND F .. / .. ....... ..... .. . . ...... ......... . ...:...::....::� � is Hill , 33 3 , /.: — — — — — T.O. PLATE - ENTRY PORCH T.O. PLATE -GA RAGE SHso 31 9 3/8 31' -31/4" -- -- PANTRY ENTRY flog 101 I Dill ENTRY PORCH FIRST FL SUBFL '' '/ FIRST FL SUBFL T.O. FND WA 8 77 22 0 0 Ll — ` ° T.O. FND. WALL-TYPICAL F 00 B 14' -2" T.O. FOOTING r ^ � V J ~ 1 SECTION E SECTION F 1/4"= 1'-0" 1/4"= 1'-0" H w FT A4.0 A4.0 A4.0 � A4.0 3 5 3 5 W �+ V J 12 12 7 / is y: B,.O. CEILING 2ND F S Q Q Q Q , 43 4 7/8 ... .:..... .......:.:::::: . .:::. ........:: T.O. PLATE - LARGE DORMERS , . , .:. ,: , .:: ,; ;; T.O. PLATE-LARGE DORMERS 40 -8 3/411 40 -8 3114 is J J J W Q Q Q '!i' L'J LLJ W „ 12 STAIR HALL 26 ;:, .. 2 LO ET BATH BEDR00 00 :. 2 0 203 202 ' `:: 26 . ' W W — <' 12 W W W 4 112 /. 7 12 Z' „ 41/2 SECOND FL L .::.:. .::. ;:. ,. ... ,,. 2 /4:... .:... .............................,.:::.:::.. ......... . . ..::.::.:.. CV CV N T.O. PLATE ENTRY�ORCHI 0. PLATE GARAGE SHED PLATE -GARAGE SHED _ CD _ i. 31 93/8 — — — — ` N 31' -_31/4" \ O \ \ - 31' -31/4" � � N 0 i STORAGEGARAGE 0 T i STORAGE D R 0 LAUNDRY U Y _ 1 05 10 105 104 10 3 0 0Lin 0 o 0. 0 FIRST FL SUBFL ' "':< O 0 11 ; FIRST FL SUBFL 22 '8 ,. ... ... .. ... ...:. . .. ., :. .. ... . . .. .... .. . .. . . . „ ..... ,.,...... :-,�.�- - T. . FND. WALL -TYPICAL / 22 8 � w ; _ 21 81/2 CD c� T.O. FND. WALL -TYPICAL. T.O. GA GE SLAB DOOR 2 _ 11 1 81/2 21 r- ..... ... ... ; T.O. GARAGE FOOTING , : 17' - 1" M T.O. SLAB < !< 14' -2" -- — — — _ — — — — 13' SECTION G dSECTION H O (V �, V U u ry o w � 9-y 4 N C v d � r) r+ rN N N i I I I aItt rrrr4 s s I io'i *-O �« 3"VENT PIPE ' 3"VENT PIPE41 Its +��� •`�r � I I I I I I I I ' I I I I ---.. -L---_ I ,, --------.---_-.....--t...,. --_,--------- l I I i 3"VENT PIPE ' 2"VENT'PIPE i 3"VENT PIPE r ' t I 2"VENT PIPE 2 V NT PIPE � i � , i i 2 VENT PIPE I I ' Ali E I I MAIN BATH 211 i i BATH 213 i I BATH 207 LAUNDRY 204 i BATH 203 ^�r n� V J H P R P(TYP.) I E I _ SECOND FL SUBFL am C! J 4"DRAIN PIPE 'I 2"VENT PIPE 3"VENT PIPE 1 2"VENT PIPE I i NOTE:ALL DRAIN PIPES TO VENT i E 3"VENT PIPE 4"DRAIN PIPE I I u 114 PER FOOT I I u I KITCHEN 110 �i BATH 117 POWDER RM 102 i i LAUNDRY 103 fill - mm ii - - - FIRST FL SUBFL 22' -g CLEANOUT r ^ "DRAIN PIPE TO SEPTIC„ 4"PER FOOT lit- T.O. SLAB 14 Q w w N O '. C—D %"' c— CW z ,,y W N A4* 2 18 WINDOW SCHEDULE WINDOW ROUGH OPENING FRAME SIZE ADDITIONAL DETAILS i- ?- a 3/4" TYPE MANUFACTURER TYPE No. WIDTH HEIGHT WIDTH HEIGHT "U"VALUE EGRESS NOTES U W A MARVIN DOUBLE HUNG UDHG2 3632 E 3'-61/4' V-0' 3'-51/4' S'-111/2' 0.31 YES (_ c B MARVIN DOUBLE HUNG UDHG2 4032 E Y-101/4' V-0' T-91/4' 6-111/2' 0.31 YES C MARVIN TRIPLE MULLED CASEMENT UCA1654AJCA5454 T-3" 4'-5 5/8' T-2" V-5118, 0.31 SIDE OPERATING CASEMENTS;CENTER FIXED CASEMENT = u D MARVIN DOUBLE HUNG UDHG2 3024 3 0114 4!-8- Z-111/4 4 71/2 0.31 .,- - E MARVIN DOUBLE HUNG UDHG2 2420 2'-61/4' 4'-0" 2' S114' 3' 11112' 0.31 U r <' r F MARVIN DOUBLE HUNG UDHG2 3228 E2 3'-21/4' 5'-4- 3'-11/4' 5'-3117 0.31 YES , Jce G MARVIN DOUBLE HUNG UDHG2 2'-81/4' 6'-0' 2'-71/4' 5'-111/2' 0.31 YES c L.C.C.FLASHING -5: H MARVIN DOUBLE HUNG UDHG2 2824 7-10114" 4'-8' 2'-91/4' 4'-71/2' 0.31 �=- ` ' I PAINTED CEDAR c BACKBAND J MARVIN DOUBLE HUNG UDHG2 3626 E1 3'-61/4' 5'-0' 3'-51/4' 4'-111/? 0.31 YES 6/ K MARVIN DOUBLE HUNG UDHG2 3226 E1 3'-21/4' 5'-0' T-11/4' 4'-111/2' 0.31 YES r< 2 2X4 PAINTED --- L MARVIN DOUBLE HUNG UDHG2 3224 3-21/4' 4-8 3-11/4' 4-71/2 0.31 CEDAR FRAME M MARVIN DOUBLE HUNG UDHG2 3230E 3'-21/4' 5'-8' 3'-11/4' 5'-71/2' 0.31 YES fg 5/4X PAINTED >~ j ? CEDAR FRAME N MARVIN DOUBLE HUNG UDHG2 4430 E 4'-21/4' 5'-8' 4'-1114" 5'-71/2' 0.31 YES c `; P MARVIN AWNING UAWN4040 T-5' T-3 5/8' T-4' T-31/8' 0.31 CEDAR SLATS _ • ,- _ • _ rk Q MARVIN AWNING UAWN4856 4 1 4 75/8 4 0 4 71/8 0.31 M 6 R MARVIN AWNING UAWN 3224 2'-9' 11-11518, 2'-8" 11-111/8, 0.31 M ICE&WATER S MARVIN FIXED CASEMENT UCA1624 T-5' 1'-115/8' 1'-4' 1'-111/8, 0.31 SHIELD BEHIND CEDAR TRIM GENERAL WINDOW NOTES: n _ 1) BEFORE ORDERING ANY MATERIALS OR DOING ANY WORK, THE CONTRACTOR SHALL VERIFY ALL MEASUREMENTS AT THE BUILDING AND SHALL BE RESPONSIBLE FOR THEIR CORRECTNESS. ANY DIFFERENCES WHICH MAY BE FOUIND SHALL BE SUMBITTED TO THE ARCHITECT FOR DECISION BEFORE PROCEEDING WITH THE WORK. a`e0 Nh0 e'*r N 2) PROVIDE SHOP DRAWINGS FOR REVIEW. + C ARS 3) SEE WINDOW ELEVATIONS FOR MUNTIN PATTERN. 4) PROVIDE TEMPERED GLASS AS REQUIRED BY LOCAL BUILDING CODES. 5) ALL MARVIN WINDOWS TO BE HURRICANE RATED (IZ3) L.C.C.FLASHING R FRAM 4XFOR �a WINDOW OPTIONS: �� 6 4 (, > j 2XPAINTED ,^0. 1) SCREENS - HALF SCREENS FOR DOUBLE HUNG WINDOWS; COLOR TO MATCH WINDOW EXTERIORw CEDAR TRIM DRIP GROOVE _ 2) HARDWARE - WHITE SASH LOCKS4'* 3) MUNTINS - 7/8" SDL W/ALUMINUM SPACER BAR a - r1 4) INTERIOR - PRIMED N 2 2 2 CUSTOM PAINTED 3 3/4" 11 " 5 GLASS: CEDAR TRIM N MANUFACTURER - MARVIN 8 8 8 514X PAINTED CEDAR TRIM GLAZING - DOUBLE PANE 1" TYPE - CLEAR LOW-E 270 514XPAINTED U-VALUE - 0.31 CEDAR TRIM SHGC - .050Am W DRIP GROOVE VT - 0.57 CR -55 GAS - ARGON FILLED 6) EXTERIOR CLAD - RED (CUSTOM) •, 7) EXTEROR CASINGS & SUBSILLS - 2" AZEK SUBSILL, 5/4X4 AZEK CASINGS. �► ^ n WINDOW N D)ETAIL SECTION WINDOWS M&N DETAIL ELEVATION 8) JAMB EXTENSION - TBD 1 9) PROVIDE COPPER SILL PAN & VICOR FLASHING AT ALL WINDOWS & COPPER HEAD FLASHING @ WINDOW HEAD CASING v 1 1/2"= 1'-0" 1 1/2"= 1'-0" 10) INTERIOR CASINGS, STOOLS & APRONS: TBD r n v ,J O V J ~ 3'-61/4'R.O. 3'-101/4"R.O. T-3"R.O. T-01/4"R.O. 2'-8114"R.O. Of 3'-2114"R.O. 2'-101/4"R.O. 1� 3'-51/4" — 3'-9114" 1'-4" 4'-6" 1'-4" " op " 2'-71/4" Z'-111/4 2'-61/4 R.O. 3'-11/4" 2'-9114" W 2'-5114" I I I I I I I I I I I I I I T o � I O I I O I Lo I � 0 , icoI I I I I I o I L? v I I v ih I r M I i cf� I I to I I I 0 ZD � I I to `� I I I I I I I I I V a a a ¢ a o 0 0 WINDOW C WINDOW D WINDOW E %J 1/2"= 1'-0" 41/2"= V-0" 1/2"= 1'-0" WINDOW F I Q WINDOW H V 1/2" = 1'-0" WINDOW A WINDOW B 7WINDOW G w W W w 21/2"= V 0 1 1/2 - 1 0 w CD F-- C z 5i z g cn u 0- u Elf En E w w a W C N N N N N N r O O 3'-5'R.O. 4'-1"R.O. of 3'-61/4"R.C. T-6114"R.O. 3'-2114"R.O. 3'-2114"R.O. tl T-21/4'R.O. 3'-5114" 3'-51/4" 3'-11/4" 3'-11/4" 3'-11/4" - 1I I r I / \ i A6.1 3'-3"M.O. T- R.O. F11 ----------- ------� ------------------I ---------- ----- ----------------� ----------------� I I I I I I �/ \\ 3 2'-8" I I I I I I I I I I i I I I I I I I I I I I I I I I I I I I I i � / \ � � I I I —___.... ..__ I I I •C g i I V O N I I I I O N I I 1 I I m ti I rA6.1-� � � Wro I I I I I I I I I I I I I / \ I WINDOW P WINDOW R II M1-011 OWS I I I I I I I I 1/2"- 1-06-yl—/2' O co I I I I 1 1 I I I I I 1/2"- 1'-0" I I I I I I I I I I I I I I F WINDOW Q ~ M I I I I I I " " 14 1/2"= 1'-0" O WINDOW 1WINDOW K 1 1 WINDOW L 3'-2114"R.O. 3' 4'-21/4"R.o. Q 10 1/2"= 1' 0" 1/2"= 1'-0" 1/2"= 1'-0" 12WINDOWS M & N 1/2"= 1'-0" A560 DOOR SCHEDULE ADDITIONAL � ROUGH OPENING DOOR SIZE DETAILS ~ _ HARDWARE U c No. MAINUFACTURER MODEL No. STYLE MATERIAL WIDTH HEIGHT WIDTH HEIGHT THICKNESS JAMB THICKNESS SET NOTES W ' E 001 THERMA-TRU CCR100 EXTERIOR DOOR(PAIR) FIBERGLASS 6'-2112' 6'-101/2' 6'-0' 6'.8' 13/4' C (2)T-0'X 6'-8'PANELS u 002 TRUSTILE TS4290 4 PANEL DOOR MDF 2'-10 1/7 6'-101/2' 7-8' 6'-8' 13/4' 2X4 P C -! 31/2"TYP 101 CUSTOM ENTRY DOOR MAHOGANY 3' 4112' T-21/7 3'-2' T-0' 21/4' 2X6 A SEE ELEVATION . M 101A CUSTOM SCREEN DOOR MAHOGANY Y-2112' 6'-10 112 3'-2' T-01/8" 1114' 2X6 D U 102 MARVIN CUIFD2668 FRENCH DOOR 2'-81/2' 8'-0' 7-71/2' T-111/2' 13/4' 2X6 G 31/7 TYP. 103 MARVIN CUIFD5080 FRENCH DOOR(PAIR) 5'-15/8' 8'-0' 5'-0 518' T-111/2' 13/4' 2X6 F 01 104 MARVIN CUIFD5080 FRENCH DOOR(PAIR) 5'-15/8' 8'-0' 5'-0 518' T-111/2' 13/4' 2X6 F WOOD EXT.JAMBS&SILL 104A CUSTOM SCREEN DOOR(PAIR) MAHOGANY 5'-2112' 8'-1114' 5'-0 518' T 11318' 1114' 2X6 E 101 O ® 106 105 CUSTOM SCREEN DOOR MAHOGANY 3'-21/7 6-101/2' T-0' 6-8' 11/4' 2X6 D 1/ O _ 106 CUSTOM SCREEN DOOR MAHOGANY 3'-2112' 6'_10 1/7 3'-0' 6'-8' 1114' 2X6 D �, r• 107 THERMA-TRU CCR100 EXTERIOR DOOR FIBERGLASS T-21/7 G-101/2' T-0' 6'-8' 13/4' 2X6 B 107A CUSTOM SCREEN DOOR MAHOGANY 3'-21/2' 6'-10 l/T T-0' 6'-8' 11/4' 2X6 D c 108 TRUSTILE TS4290 4 PANEL DOOR MDF 2'-10 1/7 6'-10 1/7 7-8' 6'-8' 13/4' 2X6 B 90 MIN FIRE-RATED DOOR 109 (OVERHEAD DOORS GARAGE DOOR FIBERGLASS 20'-2112' 8'-2117 20'-0' 8'-0' 21/4' 2X6 -� 110 SIMPSON 7944 ENTRY DOOR MAHOGANY T-21/2' 6-101/2' T-0' 6'-8' 21/4' 2X6 B M: N 111 CASED OPENING 2'-10117 6-101/2' 2'-8' 6'-8' 2X4 112 TRUSTILE TS3100 3 PANEL(PAIR) MDF 5'-21/2' S-10117 2'-8 7/8' 6'-8' 13/8' M 113 TRUSTILE TS3100 3 PANEL(PAIR) MDF 5'-21/2' 6-101/2' 2'-8 7/8' 6'-8' 13/8' M 114 TRUSTILE TS3100 3 PANEL(PAIR) MDF 5'-21/2' 6'-101/? 2-5 7/8' 6-8' 1318' M 1 DOOR 101 DOOR 101A DOOR 102 �I DOOR 105/106 115 TRUSTILE TS3100 3 PANEL(PAIR) MDF 5'-21/Y 5-101/? 7-8718' S-8' 13/8' M `y _ 1 _ 1 _ 1 �+ _ 1 112"- 1-0" 112"- 1-0" 1/2"- 1-0" 1/2"- 1 0" 116 TRUSTILE TS4290 4 PANEL DOOR MDF 7-10112' 6'-10112• 7-8" 6-8• 1314■ 2X4 H 117 TRUSTILE TS4290 4 PANEL DOOR MDF 7-1011Y 6'-10117 7-8' 6-8' 13/4' 2X4 K �. ��°' " '�,•. 118 TRUSTILE TS4290 4 PANEL DOOR MDF 7-10117 6-101/7 7-8' 6-8' 13/4' 2X4 H 119 CASED OPENING 3'-81/2' 8'-21/2' T-6' V-0' 2X4 MATCH DOOR 104 EXT.OPENING 120 TRUSTILE TS4290 4 PANEL DOOR MDF 7-10112' S-10112' 7-8' 6!-8' 13/4' 2X4 L 121 TRUSTILE TS4290 4 PANEL(POCKET) MDF 6-6112" S-10117 7-8' 6'-8' 13/8' 2X6 L 122 CASED OPENING 6-2112" 8'-03/4' 5'-0' T-10114' 2X4 123 CASED OPENING 5'-21/2 8'-0 314' 5-0 T-10114 2X6 124 CASED OPENING 4'-21/2' 8'-03/4' 4'-0' T-101/4' 2X6 { N 125 CASED OPENING T-21/7 8'-03/4' T-0' T-101/4' 2X6 126 TRUSTILE TS4290 4 PANEL DOOR MDF 3'-21/2' 6'-101/? T-0' 6-8' 1314' 2X6 J 21/2"TYP. 127 TRUSTILE TS4290 4 PANEL DOOR MDF 7-101/? 6'-10112' 7-8' 6-8' 1314' 2X4 H 128 TRUSTILE TS4290 4 PANEL DOOR MDF 7-10117 6'-10112" 7-8' 6-8' 1314' 2X4 H z 129 TRUSTILE TS4290 4 PANEL DOOR MDF 7-10112' 6'-10 1/2' 7-8' F-8' 13/4' 2X4 K 201 TRUSTILE TS4290 4 PANEL DOOR MDF 7-10 117 61-10112' 7-8' 6'-8' 13/4' 2X6 J 202 TRUSTILE TS4290 4 PANEL DOOR MDF 7-8112' 6'-101/7 7-6' 6'-8' 13/4' 2X4 K 203 TRUSTILE TS4290 4 PANEL DOOR MDF 7-21/Y 6.10117 7-0' 6-8' 1314' 2X4 P o 204 CASED OPENING 7-10117 6'-10112' 7-8' 6'-8' 2X4 1 3/1 0 L205 TRUSTILE TS4290 4 PANEL(PAIR) MDF 5'-21/2' 6'-10 1/2' 4'-01/2' F-8' 1318' M 0 Ll 206 TRUSTILE TS4290 4 PANEL DOOR MDF 7-8112' 6'-10 117 7-6' 6-8' 1318' P c=i 110 O 207 TRUSTILE TS4290 4 PANEL DOOR MDF 2'-21/2' 6-10112' 7-0' 6'-8' 13/4' 2X4 P r ^ 208 TRUSTILE TS4290 4 PANEL DOOR MDF 2'-8112" 6'-10112' 7-6' 6-8' 1314' 2X4 209 TRUSTILE TS4290 4 PANEL DOOR MDF 7-2112' 6'-10112' 7-0' V-8' 1314' 2X4 P 210 TRUSTILE TS4290 4 PANEL DOOR MDF 7-211T 6'-10112' 7-V 6'-8' 1314' 2X4 P 211 TRUSTILE TS4290 4 PANEL DOOR MDF 7-101/2' 6'-10 1/2' 2-8" 6'-8' 13/4' 2X4co J 212 TRUSTILE TS4290 4 PANEL DOOR MDF 7-8112' 6'-101/7 7-6' 6'-B' 1314' 2X4 K o 213 CUSTOM CONCEALED DOOR 7-2 W' 4'-5' 7-0' 4'-3 7/8' 13/4' 2X6 (f� N 214 CASED OPENING 7-10it? 6-101/7 7-8" F-8' 2X6 (� H 215 TRUSTILE TS4290 4 PANEL(POCKET) MDF 5'-2112' 6'-1011Y 7-6' 6'-8' 1318' 2X4 L 216 TRUSTILE TS4290 4 PANEL DOOR MDF 7-10it? 6'-101/2' 2'-8' F-8' 13/4' 2X6 J 217 TRUSTILE TS3100 3 PANEL(PAIR) MDF 6-2112' 6'-10112' 3'-0' 6'-8" 1318' M 5 DOOR 103/104 DOOR 104A '7 DOOR 110 218 TRUSTILE TS4290 4 PANEL(POCKET) MDF 6-2112' 6-101/2' 7-6' 6-8' 13/8' 2X6 L 1/2"= 1' 0" 1/2"= 110" / 1/2"= 1'-0" 219 TRUSTILE TS4290 4 PANEL DOOR MDF 7-8112' 6'-101/Y 7-6' 6',8' 1314" 2X4 K 220 TRUSTILE TS4290 4 PANEL(POCKET) MDF 4'-10 11? 6-101/2' 74 4' 6'-8' 1 T8' 2X4 L 221 CASED OPENING 7-101/2' S-10112' 7-8' 6'-8' 2X4 (f� 222 TRUSTILE TS4290 4 PANEL DOOR MDF 7-21/7 6'-10 1/2: 2'-0' 6'-8' 1314' 2X4 P 223 TRUSTILE TS4290 4 PANEL DOOR MDF 7-101/2' 9-10117 2'-8- 6'-8' 1314' 2X4 J W w 224 TRUSTILE TS4290 4 PANEL DOOR MDF 7-811Y 6-101/2 7-6' 6'-8' 13/4' 2X4 K T , 225 TRUSTILE TS4290 4 PANEL(POCKET) MDF 5'-21/2' 6-101/2' 2'-6' 6'-8- 1318' 2X6 L F1�1. 226 CASED OPENING 7-10117 6'-10112' 2'-8' 6'-B' 2X6 rr ' N j I li j GENERAL DOOR NOTES: 1)BEFORE ORDERING ANY MATERIALS OR DOING ANY WORK,THE CONTRACTOR SHALL VERIFY ALL MEASUREMENTS AT THE BUILDING AND SHALL BE RESPONSIBLE FOR THEIR CORRECTNESS. ANY DIFFERENCES WHICH MAY I � BE FOUIND SHALL BE SUBMITTED TO THE ARCHITECT FOR DECISION BEFORE PROCEEDING WITH THE WORK. A 3112"TYP. 2)SEE PLANS FOR HANDING. a Q Q Q U o 0 0 0 N 3)PROVIDE ARCHITECT SHOP DRAWINGS FOR REVIEW (7� 0 O C? O 4)DOOR HARDWARE TBD (xj i 01 ! 5)DUMMY KNOBS ON DOUBLE CLOSET DOORS W/ADJUSTABLE BALL CATCHES O 7 J J ! j j 6)POCKET DOORS TO HAVE HAFELE HARDWARE-HAWA JUNIOR 402 w w w w N — 77 TRUSTILE TS3100 AND TS4290 DOORS TO HAVE 9"TOP AND BOTTOM PANELS.DOORS TO BE MADE OF LOW-FORMALDEHYDE MDF.PANELS TO BE TYPE A W/OGEE STICKING. A 8)ALL INTERIOR DOORS TO BE SHOP PRIMED j 9)ALL EXTERIOR DOORS TO HAVE WEATHERSTRIPPING tow F w 1� w a_ a DOU 001 Q DOOR 107 DOOR 107A TYPICAL INTERIOR DOOR DOOR HARDWARE SCHEDULE V 1/2 - 1 0 1 1/2 - 1 0 11 1/2"- 1 0 DOOR HARDWARE SET N N N N 1/2" " "_ '_ " "- 1_ " _ 1_ " LOCKSET W N N N CN HARDWAI'RE SET TYPE MANUF. KNOB MODEL# ROSE FINISH TYPE MANUF. MODEL# FINISH BACKSET HINGES A A MAIN ENTRY BALDWIN THUMB LATCH 6571 EXT15015 INT TBD MORTISE ENTRY SET BALDWIN 6571 TBD BALDWIN SOLID BRASS BALL BEARING W/BALL FINIALS B ENTRY BALDWIN KNOB 5015 5017 TBD DEADBOLT BALDWIN 6756 TBD C BASEMENT ENTRY BALDWIN KNOB 5015 5017 TBD MORTISE ENTRY SET o D SCREEN DOOR LEVER TBD E SCREEN DOOR(PAIR) LEVER TBD F FRENCH DOOR(PAIR) BALDWIN LEVER 5445V MP004 TBD MULTIPOINT BALDWIN MP004 TBD W I I G FRENCH DOOR BALDWIN LEVER 5445V MP004 TBD MULTIPOINT BALDWIN MP004 TBD H PASSAGE BALDWIN KNOB 5015 5017 TBD TUBULAR BALDWIN J PRIVACY BALDWIN KNOB 5015.PRIV 5017 TBD TUBULAR BALDWIN u j ! I K PRIVACY-BATH BALDWIN KNOB 5015.PRIV 5017 TBD TUBULAR BALDWIN L POCKET BALDWINIOMIA EDGE PULLIFACE PULLS O4651653 NIA TBD W 1 9 ! ! M DOUBLE DOORIDUMMY BALDWIN KNOB 5015 5017 TBD MAGNETIC CATCH BALDWIN DUMMY KNOB OUTISIDE ONLY = a! ! ! N PASSAGE SPLIT FINISH BALDWIN KNOB 5015 5017 TBD TUBULAR BALDWIN U (� ! ! j P CLOSET BALDWIN KNOB/CLOSET SPINDLE 501516748 5017 TBD TUBULAR BALDWIN CLOSET SPINDLE ON INTERIOR OF CLOSET N ! ! n,, c� I W o Z I I ! o ! I H o 0 1 DOOR 109 1/2"= V-0" • 00 12 }..{ I C / 1 c 26 - i.l RED CEDAR SHINGLES @ 5"T.W. 4-4 < ,..., 30L6.FELT(BUILDING { PAPER UNDERILAYMENT 5/8"CDX PLYWOOD SHEATHING ICE&WATER SHEILD),T STRIP ;. < , . >..: ; ' ^,...! ,...� ;�/ I` i @ EAVES AND,VALLEYS 5-., ,.� �� ,...., ,..., -; >...., ,...t �-..-;�--;.-_<'-'...., CLOSED-CELL FOAM INSULATION > < ,....<'` j r .- ;. DIRIP EDGE ....t , < > ^,.... , ; ...., ,.--,, �-� CLOSE �.._� ...: TRIPLE STARTER;COURSE ;-- �,.- D-CELL FOAM INSULATION ` ` + >:�; CLOSED-CELL FOAM INSULATION ;. ` SECOND F tX FASCIA t ,...<' ,..{ 2 -< - .... .� S L SUBFL ,. , ; 2 Fi COPPER HALF-ROUND GUTTER 33' /4"— — — — — E F ;^ 3' 4" — — — — — ;-- — T.O. PLATE - BEDROOM 116 2 '> . ,.. 3 2 3/ 2 2 2 - T-l"RADIUS - ... .. T-1"RADIUS 3� 1' -41/2" 11� — — — — 8 g 2X8 FLOOR JOISTS 2 2 5/8 CDX PLYWOOD SHEATHING �: �►-<�� „ 8 - 1X4 VGROOVE SOFFIT 1X4 STRAPPING @ 16"O.C. \' {, ? ; @ 16 O.C. 5/8 CDX PLYWOOD SHEATHING �., 8 ICE&WATER SHEILD T STRIP o CUSTOM BED MOLDING 8 8 8 1/2"GYPSUM BOARD ICE D AST P @ EAVES AND VALLEYS -, ;�� >- WATER SHEIL RI '--� & @ EAVES AND VALLEYS (�,-...�, < �R* ,•• 4� 1X,TRIM;ALIGN W/TOP OF WINDOW CASING 1X BLOCKING TRIPLE STARTER COURSE ` :' `� v •' i...' a •. •e �' a �d f 2 � TRIPLE STARTER COURSE 5/4X BLOCKING �,..., DRIP EDGE J,...; ..., m o �' (3)2X8 HEADER W/1/2"PLYWOOD DRIP EDGE r `; ` `"• •' 5/4X4 EXTERIOR WINDOW CASING _ 1X FASCIA , 1 ...>... �_<�... 1X FASCIA _1.......%?...�..�,,..`1 �_` � _ •� o ,. .. 0 5"COPPER HALF ROUND GUTTER — 5 COPPER HALF-ROUND GUTTER it i i �aa pr. -< i COPPER SILL PAN -� � . 1 2 2 ..., 1X4V-GROOVE SOFFIT 2 CUSTOM BED MOLDING AZEK SUBSILL ;...{ `,....; } , ;...,,.... 8 8 8 D CEDAR SHINGLES @ 5"T.W. {` 1X TRIM;ALIGN W/TOP OF WINDOW CASING 1X BLOCKING (3)1 3/4"X 18"LVL BEAM 5/4X BLOCKING (3)2X4 HEADER W/BLOCKING ..... 1X6 VERTICAL V-GROOVE BOARDS ' <' 1X8 BASEBOARD W/6660 CAP `. <? `; 1X8 BASEBOARD W/B660 CAP V J 1 CLOSED CELL FOAM INSULATIONI 3/4"OAK FINISH FLOOR 3/4"OAK FINISH FLOOR 1/2"CDX PLYWOODi ' ; 3/4"PLYWOOD _; }-., YWOOD SUBFLOOR 3/4"PLYWOOD SUBFLOOR 2 RED CEDAR SHINGLES @ 5"T.W.. < ;...; ,... ;....t FIRST FL SUBFL 2 FIRST FL SUBFL ICE&WATER SHIELD ON TOP OF 2 -,..; �ZC�6RCFrAN6�EOK701STS i 22' -8" — — — — — 2 -, 22' -8" 5/4X4 IPE DECKING 2 i-;_:`, 10 FLO JOIST 16"0. 10 FLO JOIST 16"0. RED CEDAR SHINGLES @ 5"T.W. TO MATCH EXISTING (T TAL F 0 R= 21 (T TAL F 0 R= 21 ~' 0 .\ 3/8"MDF PANEL 0 ^; . BENJAM/IIN OBDYKE HYDROGAP BUILDING WRAP 2 2 ,�.; �, H 1/2 CDX PLYWOOD SHEATHING F-42 F$] POLYON 0 R A RIGISD P TY-ISO %_..,�/ _ W OVERHANG SHEATHING PAST T.O.FOUNDATION WALL 1' _--- 2X10 JOISTS @ 16"O.C. 1 1 2° ��^� BROSCO 8575 MOLDING 3/8 STILES AND RAILS �- CLOSED CELL FOAM INSULATION ' 'mm 3/4"OAK FINISH FLOOR T.O. FND. WALL- TYPICAL ' ° 9 i j o : — — la' ; °,Pi'o .. ° T.O. FND. WALL-TYPICAL d I alj — — 21' -8 1/211 - L.C.C.TERMITE SHIELD - - i I �� i 21' -$ 1/2" :•a 3/4"PLYWOOD SUBFLOOR I \\ I 1/2"CDX PLYWOOD , `\ y . RED CEDAR SHINGLES @ 5"T.W. ��`�� (2)2X10 P.T.LEDGER I I ���I i �22 T FL SUBFL ICE&WATER SHIELD ON 2 Q- . , $t i1 1 jTOP�FALL�O DECK I� L.C.C.TERMITE SHIELD d. I I I 2 x PARGE EXTERIOR OF FOUNDATION j 5/4X4 IPE DECKING 10 FLO JOIST 16"0. , '' o 0 l i i WALL UNDER DECK (T TAIL O R= 21 0 ,> li ii 11 ii 2 2 '' I II II R RIGID P LY-ISO 2X10 JOISTS @ 16"O.C. A T I 1 I �2 ?- FND. WALL,,TYPICAL _ _ _ I 1 1 1/2"SHEETROCK 1/2" w wR-10 2"RIGID XPS INSULATION i i i ly a l i i 11 I I 101/4"SUPERIOR WALL PRECAST-CONC. FINISHED GRADE;SLOPE AWAY FROM BUILDING I� I I DAMP PROOFING i i i i ' 11 1 I I I 1 I FOUNDATION WALL.SEE INSTALLATION SPECS FOR ANCHORING/REINFORCING 1 i i 11 1 I 1X P.T.FORM BLOCK FILTER FABRIC;WRAP AROUND GRAVEL I I I I (2)2X10 P.T.LEDGER I1 II II 11 I 10 MIL.PLY VAPOR BARRIER ON TOP OF 1 4„FOOTING DRAIN HOLES DOWN L.C.C.TERMITE SHIELD R 10 2"RIGID XPS INSULATION 11 I I DRAIN TO DAYLIGHT '' i I i i INSULATION,TAPED SEAMS,WRAP UP WALL 2" I y ° 4 t II II I1 II 1 1 1 1 1 2"XPS INSULATION a I_I a 11 DAMP PROOFING 1 1 1 I I I �� PARGE EXTERIOR OF FOUNDATION WALL CONCRETE SLAB;SEE ST UCTURAL c"I N I I I 1 I 1 �'' I 1 DWGS FOR DETAILS UNDER DECK °a T.O. SLAB I I . I I I I• a 1l. `: � o — q a 1/2"SHEETROCKy - ----u o 1 i i 101/4"SUPERIOR WALL PRECAST-CONC. i CD FOUNDATION WALL.SEE INSTALLATION COARSE GRAVE . ,. ;, 8-12"MIN.:'.: . SPECS FOR ANCHORING/REINFORCING NO FINES'. $ BED OF LIVING ROOM BAY DETAIL SECTION I 1, CRUSHED GRAVEL,' (FILTER FABRIC;WRAP AROUND GRAVEL i i COMPACTEb'; 1X P.T.FORM BLOCK _I I� » >: Q 4"FOOTING DRAIN HOLES DOWN I I i I 10 MIL.PLY VAPOR BARRIER ON TOP OF N 1 INSULATION,TAPED SEAMS,WRAP UP WALL 2" DRAIN T \ 0 DAYLIGHT : 2 XPS INSULATION '< : CONCRETE SLAB;SEE STRI JCTURAL N 1 CDT.O. SLAB I I �'' I I DWGS FOR DETAILS i, II 14' -2„ II a WALL DETAIL SECTION D - �- ECIK 2 0 COURSE GRAVEL 6-12"MIN. 8"BED OF. NO FINES' CRUSHED GRAVEL,. c— COMPACTED . J CV. .. t �I (BEDROOM 116 EAVE DETAIL I 1 1/2"= 1'-0" 00 12 RED CEDAR SHINGLES @ 5"T.W. '-- 30LB.FELT BUILDING U C ;.... ....t >...:' PAPER UNDERLAYMENT 518 DX PLYWOOD SHEATHING \ S o ui ` ICE&WATER SHEILD,3'STRIP ��U Q '� @EAVE AND VALLEYS T � ^,....' ,.....J...{'-``^',.._� CLOSED CELL FOAM INSULATION , , ry }... .,.� ,...; `-J --ti ... .... }... �' TRIPLE STARTER COURSE cV 2X10 CEILING JOISTS v ' ',,.;� @ 16"O.C. 9^...tom ;....; T.O. PLATE -SMALL DORMERS In 2 2 2 DRIP EDGE 41' -4 3/4" c 4- lX3 STRAPPING @ 16"O.C. 6 6 6 AZEK CROWN MOLDING 47 ,0 1/2"GYPSUM BOARD 1X FASCIA U- f?.... rct -....(✓...;� \ 3 2X6 HEADER W/1/2" ( ) 1X4 V GROOVE T&G BOARDS ;...; PLYWOOD 5/4X BLOCKING , 5/4X4 EXTERIOR CASING r, Y60 pi. ~ ( >.... ;. { ;..., }.... `...,.... AZEK SUBSILL �~ •• , ;� \. �A• ( '^,..., {'��.... , {�'.,. f ...� ` ,...:... i 6= ice '+ •. 2X8 CEILING � '. ,..,'�`.....� �,..J'.. ,.. ... <,... ; �, `� •.•.: :� .. ?°> ` �: JOISTS @ 16"O.C. ....., {>...;.. B.O. CEILING -_2ND FL BEDRMS 43'-4 7/8" — — — — — — — — — < ;.. }.. , 1 SMALL DORMER EAVE DETAIL SECTION 12 . � `, SPRAY FOAM `< , ' INSULATION �� { RED CEDAR SHINGLE @ 5"T W A @ ~' A „ 16"O.C. {` 2X12 RAFTERS ` > ~' 30LB.FELT BUILDING ( @ 16"O.C. ,� ,...,,..... < ,....., PAPER UNDERLAYMENT ..;^... >... -< DX PLYWOOD SHEATHING ;... - ... {` }..; ICE&WATER SHEILD,3 STRIP 2X8 CEILING JOISTS @ , , � @EAVES AND VALLEYS , TRIPLE STARTER COURSE 2 2 2 2 2 T. PLATE - SMALL DORMERS 2X8 CEILING JOISTS > r 8 8 @ 16"O.C. - � @ 16"O.C. 4 1/2"GYPSUM BOARD 41' - 3/4" u T.O. PLATE - LARGE DORMERS ? ` ' ; _ ( )2X6 HEADER W/1/2"PLYWOOD 40' -8 314" — — — — - - �' - - �- - � - - 2 2 2 DRIP EDGE 7 AZEK CROWN MOLDING 47 I FASCIA LARGE DORMER EAVE DETAIL SECTION 1X4V-GROOVET&GBOARDS 5/4X BLOCKING i 1X6 FASCIA 5/4X4 EXTERIOR CASING MAIN BEDROOM SMALL DORMER CLG DETAIL SECTION COPPER SILL PAN 1 1/2" = 1'-0" AZEK SUBSILL »> , _ Q RED CEDAR SHINGLES(@ - •-� CD 0 5"T.UN. Q t 30L.B.FELT BUILDING PAPER 12 1X WOOD APRON&STOOL UNDERLAYMENT 4.5 CLOSED-CELL FOAM INSULATIo)N `r "�� L.C.C.FLASHING 5/8"CDX PLYWOOD SHEATHINIG , ICE 8.WATER SHEILD,3'STRI IP 2X6 STUDS 1611 0 @ EAVES AND VALLEYS ^>.... T; ' CLOSED CELL SPRAY FOAM SUS@ C DRIP EDGE ! �,.. \ _ ?�" �'(6.'�.. �,._ �. ( ^ �/� INSULATION TRIPLE STARTER COURS3E � R ,...- ....; 1 2 GYPSUM BOARD ~' ;....{ > / YP ARD > c� 1XFASCIIA � � `_,>-.., ;..{ ,..` > ., �` gyp; ;�;} }... ;_; t > 1 X8 J}...: " w 5"COPPER HALF-ROUND GUTTER > < ~' w j— ...T— ...t.*y II 3/4 PLYWOOD SUBFLOOR ^' - I II _�;zy�-,,—���;._, , �' �r ,...�.. � >..,\..., RED CEDAR SHINGLES @ 5"T.W. ol 1 1 1l2 ( jR.._ , \ .. ;....i L BUILDING 2X6 CEILING JOISTS @ 16"O.C. 1...%5 , < , ( PAPER UNDERLAYMENT CN 2 , II T.O. PLATE -GARAGE � �-��� -•- G G SHE 2 1X4 STRAPPING @ 16 O.C. 31 -3 1/4 1/2 GYPSUM BOARD ,..., ~` 5/8"CDX PLYWOOD SHEATHING, J> O ' 2X8 FLOOR J(01 ;.... �....{ , .....?...;... 16 O.(C. -< %-`, ICE&WATER SHEILD 3 STRIP T {: •' ,`. ,. (2)2X6 TOP PLATE @ , II, _, .._{ , • > •.._[ y..,�... ,...,` •....<'-`>..., ,_, � `�'. �...;�;... EAVES AND VALLEYS C� 2X6 WALL STUDS 16 O.C.W/ ^ CELL SPRAY FOAM INSULATION ;-' >-<' .-t. "r , TRIPLE STARTER COURSE ...., f v DRIP EDGECN ANDERSON MCQUAID ., `..tom... ....; ;...,�}...` ;...; L� � 1 FASCIA ` 1/2"CDX PLYWOOD > : 3/4"OAK FINISH FLOOR 5030 COVE MOLDING { ' ' } X F SC RED CEDAR SHINGLES @ 5"T.W. 3l4"PLYWOOD SUBFLOOR 1/2"GYPSUM BOARD 5"COPPER HALF-ROUND GUTTER <la>< FIRST FL SUBFL 2 O 1X3 STRAPPING 22' -8" BLOCKING AS REQ'D ( ' 1' 1 1/2" � .........:.............. T.O. PLATE - KITCHEN �. L.C.C.TERMITE SHIELD .�. 2X10 LOOR J STS @ "O.C. W 31' -6 3/4" I, - lX8 POPLAR TRIM 2 p N PAR;GE EXTERIOR FACE OF CONCRETE I� 1 (TO A FLO R 21) "> (� a;•a 1/�I (3)1 3/4"X 18"LVL BEAM co d :9-I: R 4 RIGID P LY ISO (2)2X6 TOP LATE 2 2 2 4 2X4 HEADER FROM BLDG(TYP.) I I ( ) 1X4 V GROOVE T&G SOFFIT ; Q LAT - - 5/4X POPLAR TRIM CUSTOM BED MOLDING ;: " BLO KING 6 6 6 1f.0. FND. WALL - TYPICAL — = i ° 2 -- — I 2X BLOCKING 21 -81/2 I�° a I is o I, 1X4 STRAPPING @ 16 O.C. 1/2"CDX PLYWOOD 1X WOOD TRIM R-10 2"RIGID XPS INSULATION ' 4 1/2"GYPSUM BOARD j DAMP PROOFING 5/04 EXTERIOR WINDOW CASING • 5 PANTRY EAVE DETAIL KITCHEN DINING AREA EAVE DETAIL 1 1/2"= l'-0" W 12 RED CEDAR SHINGLES @ 5"T.W. 30LB.FELT BUILDING � v� Z PAPER UNDERLAYMENT v 4, 5/8"CDX PLYWOOD SHEATHING ( � oR1FTFRs \ @EAVES AND VALLEYS STRIP ��--.yy/ 0 @�s„ ILL Oc o DRIP EDGE 'C7 1X PAINTED CEDAR FASCIA \ C TRIPLE STARTER COURSE u � 2X8 CEILING JOISTS @ 16"O.C. 5"HALF ROUND COPPER GUTTER Ln T.O. PLATE - ENTRY PORCH 4- 1'-2 3/4" N BLOCKING AS REQ'D N 1X4 V GROOVE T&G CEILING 1X4 V-GROOVE T&G SOFFIT;ALIGN W/TYP.EAVE BOARDS BLOCKING CUSTOM BED MOLDING 1X8 PAINTED CEDAR TRIM (3)1 3/4"X 11 17/8"LVL BEAM 4,,,,`��etHbO ��os�, BLOCKING �6. �� •s., �,y4 r ��E, •tea y��d 1X PAINTED CEDAR TRIM FLASHING AT TOP OF PILASTER(TYP.) � c .tom+-� �, Lo to .i c . (I p: PILASTER CAPITAL TBD •W? �b�: ENTRY PORCH EAVE DETAIL 1 1 1/2" = 1'-0" �'�,►a ut ,�,,, psi 1X8 W/BEVELED TOP — FIRST FL SUBFL ICE&WATER SHIELD ON TOP OF 22' -8" 5l4X4 IPE DECKING W/BLIND ALL PORCH AND DECK JOISTS FASTENERS r ^ � vJ 2X8 JOISTS @ 16"O.C. 1 2 ^ �J SIMPSON STRONG TIE ABE66 POST BASE O_ 10"DIA.CONC.FILLED SONO-TUBE 1X AZEK RISER TRIM r ^ P.T.STAIR FRAMING .. _ . _ _ _ _i i i i E II ... " .........i I....... .............! -j <: CON , aQ - - ............ ...........- ..... �....... _ ............ f...._....... f.... ..... ° ,<=FOQTINGQ-,. ........ 1 -....... Qa = : =°. .._....... ------ W w 2 ENTRY PORCH FOUNDATION DETAIL 11/2 - 10 . Q o 0 AZEK SUBSILL L.C.C.FLASHING 1...- CLOSED CELL SPRAY FOAM INSULATION Q Q w Li 1 X WOOD APRON&STOOL -~> ^ LLJ 2X6 STUDS @ 16"O.C. ._< ....i� CLOSED CELL SPRAY FOAM "4... �. INSULATIONCN o 1/2"GYPSUM BOARD 1X8 BASEBOARD W/8660 CAP 12 3/4 WOOD FINISH FLOOR g \ r RED CEDAR SHINGLES IN ES @ 5"T.W. 3/4"PLYWOOD SUBFLOOR i ;. { ,..�... ;...<,... , ,...' 30LB.FELT BUILDING { PAPER UN ',SECOND FL SUBF is 3' �� Q N ;...., , 3 -23/4 r-< { 5h8 CDX PLYWOOD SHEATHING ,..., ICE&WATER SHEILD, TRIP t!3' 1.... AND VALLEYS' � \ AYES A CD ♦ i� DRIPn. E CN D TRIPLE STARTER COURSE , (3)1 3/4"X 11 718"LVL BEAM .., ? - 5"COPPER HALF-ROUND GUTTER '( W , 1X PAINTED WOOD TRIM ; W T.O. PLATE -GARAGE DOOR 2 1X3 STRAPPING @ 16"O.C. 1/2"GYPSUM BOARD ;. 1X4 V-GROOVE T&G SOFFIT (2)2X6 TOP PLATE ;� ;... CUSTOM BED MOLDING GARAGE DOOR EAVE CETAI 2X BLOCKING 1 1/2" = 1'-0" I WOOD TRIM k N 00 UP WATER SPIGOT W i ----------------- ----------------- ------- ----- I --- O U 4-j rA I � WP � C U °Nttaa`tryt4 ,' DECK ABOVE ;�••.```.•• ��,yo'»� L, PORCH ABOVE DECK ABOVE ,,� fy ocn , WATER SPIGOT 4-4 ry I I I I C3 I I UP > iV qp P \ I db I I I I I I I I I I I I I I I I EQ EQ EQ EQ 4'-0" EQ I EQ EQ I EQ EQ I EQ EQ EQ 3'-5114"' 1 6'-0" j. ------ ---o 1---- --------------- -------------- -- --------- -- ------ ---- ------------------- ----- --------- -------�---- - ------Z-°-I-------------------L-°- ---------- 01 ER �{ BASEMENT-STORAGE I I��j & MECHANICAL F� 4 H ., O _ o r ^ ------ ---- — — V J ~ -- ------------- ----C-o-- --- - -- -- --- ----------- ----------- --L------- ----I c- ------------I---I--------- r— 1 r— EQ EQ L i J EQ E EQ I — J EQ L _ � I I I 111 I iiui I ii 1 I I I I I I I I I I I V I I I I u.l I I I I I I I I I I I I I I I I I I I I I 1 I ELECTRICAL SYMBOL IKEY LLI SYMBOL SWITCHES SYMBOL OUTLETS SYMBOL LIGHT FIXTURES i I I I I '-17 — � ; F PORCH $ SWITCH DUPLEX RECEPTACLE OUTLET CEILING FIXTURE(SURFACE) i01 i ABOVEqp < DUPLEX RECEPTACLE OUTLET - THREE WAY SWITCH J II I - -$3 W/TWO USB PORTS ( SED) P Q QU o 0 $a FOUR WAY SWITCH DUPLEX RECEPTACLE OUTLET CEILING FIXTURE(RECESSED WALL I n WP WATERPROOF O WASHER) i i w� 1 DUPLEX RECEPTACLE OUTLET I I $D SWITCH W/(DIMMER 9 GFIC W/GROUND FAULT INTERCEPT CIRCUIT WALL SCONCE I ; $ HORIZONTALLY MOUNTED OUTLET IN wP WATERPROOF SWITCH es BASEBOARD UNDERCABINET LIGHTING J J ui - - - $ JAMB ACTIIVATED SWITCH qp QUADRUPLEX RECEPTACLE OUTLET STEP LIGHT Li w I I I $L LIGHTED SWWITCH O DUPLEX RECEPTACLE OUTLET EXTERIOR SPOTLIGHT(SAVE I " 1� FULL SWITCHED MOUNTED) I m DUPLEX RECEPTACLE OUTLET � Ir HALF SWITCHED Lf} CEILING MOUNTED EXHAUST FAN I rr,*F I I hti CD I I z ~ DUPLEX SPECIAL PURPOSE Q /� � SYMBOL PANELS RECEPTACLE OUTLET }x CEILING PADDLE FAN I ) �F, � O D I I � a C� ELECTRICAkL PANEL RECESSED PICTURE LIGHT OUTLET qp 3 I ELECTRICAIL SUB PANEL DUPLEX FLOOR OUTLET N N ® TELEPHONE PANEL QUADRUPLEX FLOOR OUTLET DATA PANEL TELEPHONE OUTLET,CAT-5 WIRE WIRJ11 PORT SYMBOL DETECTORSIALARMS/CONTROLS CABLE MODEM DATA OUTLET,CAT-5 WIRE W/RJ45 PORT S SMOKE DETECTOR O 4-PORT NETWORK ROUTER COMBO PHONE&DATA OUTLETS,CAT-5 WIRE U 0 CARBON MONOXIDE DETECTOR (WALL O W/RJ11 PORT&CAT-5 WIRE W/RJ45 PORT MOUNTED) _J WIRELESS NETWORK Q ROUTER ® COMBO PHONE&DATA OUTLET H O HEAT DETECTOR U TV o COAXIAL CABLE JACK FOR TELEVISION OR c� COMPUTER LT LOW TEMP DETECTOR COAXIAL CABLE JACK FOR BOTH T [- LJI SYMBOL FIRE ALAfRM SYSTEMS � � TELEVISION&COMPUTER '_' THERMOSTAT FX FIRE EXTINIGUISHER SYMBOL AUDIO SYSTEMS 4 HUMIDISTAT UNEXCAVATED "' LLJI HEAT RECOVERY VENTILATION CONTROLS SPRINKLERS sP CEILING SPEAKERS(RECESSED) HRV �- : z34 FIRE ALARW HORN/STROBE SP SPEAKER JACK(WALL MOUNTED) K ALARM KEYPAD " W W FIRE PULL,STATION Sp SPEAKER JACK(SURFACE MOUNTED) SC SECURITY CAMERA U) � EX EXIT SIGN 4 AUDIO VOLUME CONTROL ALARM MOTION DETECTOR m c � EM EMERGENCY LIGHTING DOOR BELL AD ALARM DOOR CONTACT 172 NOTES: 1.PROVIDE HOMERUNS TO AL.L PHONE/DATA/TV CABLES 2.REVIEW ELECTRICAL DEV0E TYPE AND COLOR WITH ARCHITECTS BEFORE INSTALLATION OF FINISHED ELECTRICAL WORK 3.REVIEW LIGHTING FIXTURE SPECIFICATIONS FOR BOX TYPE&LOCATION 4.REVIEW INTERIOR ELEVATIONS FOR LOCATIONS OF ALL EXPOSED ELECTRICAL WORK 5.PROVIDE CUTSHEETS OF SPECIAL ELECTRICAL EQUIPT.:T-STATS,HRV CONTROLS,OUTLETS,DETECTORS,&CONTRACTOR SUPPLIED LIGHTING 6. REVIEW TRANSFORMER LO(CATIONS FOR LOW VOLTAGE AND LED LIGHTING 7.ALL LIGHT SWITCHES CENTEERED AT 41"A.F.F.EXCEPT WHERE NOTED 8.ALL ELECTRICAL OUTLETS IIN BASEBOARD EXCEPT WHERE NOTED I r-——————— ——————————————————————————————————————————————————————— ------I co 00 I , � C CD {V] =-=_ — — — — — — — — — pN -----WP ------------------ ---------- W I II II I 1 c} I I II I II �.•, �I`e,o,„oc•���•s�„�•P�'�t`��ecy ��y��•.3•«. �*a � ytiN+�CUCv,r-v;� ' Id��+4 y � EAST DECK 4 -1, 3-4 3V-.- a4 gc', ry WEST DECK SCREENED PORC 112 . o . •to ", COVE ------ -------------- --- ♦ N LGS wP I I ----------------------- IT IIII - '_-0_7--_----_-_--_--_—II ^-_---IIIIIII -g_ _--�---III1I1I--jIIIIIIIIl+DIIIIIIlIFIIII lIIIii IIII_----_------_-1— - --1Y_IIIIIIIIIIIIIiiIIi1II iIII III1II — IIIIIII — --—-JIiIiIIIIIIi,III,I11II - I1 I 0--IIIIIIIIIIIIIII III III-J --- III--— IIIIIII1IIIIIiIIII1IIII IIIIIiII —IIIIII1IIIIIIIIi IIII,IIIII IIIIIIiIII -- ------III BBBB �3 1 GFIC pW 11 IIIIiIII,III1III1IiI1I IIIII ______ ______ INEKIT B DROOM TO 6 BB MCRO.I ICUBBY O u--- co O-____ _______ ______ _ TVABOVE B I l i DW LIVI GC OVENS ; BB BATH 3 4 t i iH Ilt IIIiI II I1IIlI1I � I III II I I\I I I\II I I1IIII1 IIIIIIII IIIIIIIIIIIIIIIII 1 .. c\0 ON gg 6gg p -SIDEBOARD ICE WINE STORAGE IL------------------------------------------ GREF. GFIC _-- -= =-=--- ------ ---_ _ -------------- I ___ R I wPCOVE LIGHTS ABOVE WVbLDINGET_RY PA Y iI DINgg B ELECTRICAL SYMBOL KEY 3 B9 — -- ----- -------- 3 SYM130L SWITCHES SYMBOL OUTLETS SYMBOL LIGHT FIXTURES ENTR ORCH BB F SWITCH DUPLEX RECEPTACLE OUTLET CEILING FIXTURE(SURFACE) STA WITC BELOW DR R DUPLEX RECEPTACLE OUTLET SMT TAI s THREE WAY SIWITCH use CEILING FIXTURE(RECESSED)W/TWO USB PORTS 4 FOUR WAY SVJTCH wP DUPLEX RECEPTACLE OUTLET CEILING FIXTURE(RECESSED WALL WATERPROOF F' ` $p SWITCHW/DIN4MER �cFlc DUPLEX RECEPTACLE OUTLET WALLSCONCE MUD 00 W/GROUND FAULT INTERCEPT CIRCUIT 4TO m HORIZONTALLY MOUNTED OUTLET IN 166 GFIC wP WATERPROOF-SWITCH o UNDERCABINET LIGHTING - - - --BASEBOARD ABOV TO _o _� 33 WITCH JAMB ACTIVATFED SWITCH QUADRUPLEX RECEPTACLE OUTLET STEP LIGHT ABOVE DUPLEX RECEPTACLE OUTLET EXTERIOR SPOTLIGHT(EAVE LIGHTED SWITFCH FULL SWITCHED MOUNTED) DUPLEX RECEPTACLE OUTLET ILAUNDRY CEILING MOUNTED EXHAUST FAN kLv 103HALF SWITCHED 3 BB SPECIAL PURPOSE SYMBOL PANELS CEILIN PA FAN o`wwJ_w¢�QOW—�U I JzJ_w¢ �1`Q z w RECEPTACLE OUTLET ELECTRICAL P?ANEL T RECESSED PICTURE LIGHT OUTLET N �ELECTRICAL SUB PANEL � DUPLEX FLOOR OUTLET TER�PIGOT o TELEPHONE PANEL QUADRUPLEX FLOOR OUTLET ..................................................... ........ TELEPHONE OUTLET,CAT-5 WIRE W/RJ11�� DATA PANEL PORT SYMBOL DETECTORSIALARMSICONTROLS CABLE MODEM DATA OUTLET,CAT-5 WIRE W/RJ45 PORT SMOKE DETECTOR COMBO PHONE&DATA OUTLETS,CAT-5 WI ui J_wQ �N CD4-PORT NETWORK ROUTER RE CARBONMONOXIDEDETECTOR (WALL W/RJ11 PORT&CAT-5 WIRE W/RJ45 PORT MOUN 1©I �WIRELESS NETWORK S RAE COMBO PHONE&DATA OUTLET HEAT DETECTOR 105 1 1 1 , COAXIAL CABLE JACK FOR TELEVISION OR COMPUTER TOR GA G LJLOW TEMP DETEC 1—z COAXIAL CABLE JACK FOR BOTH TELEVISION&COMPUTER FIRE ALARM SYSTEMS _ THERMOSTAT 104 FIRE EXTINGUISHER SYMBOL AUDIO SYSTEMS HUMIDISTATC=� HEAT RECOVERY VENTILATION CONTROLS % SPRINKLER OCEILING SPEAKERS(RECESSED) DOOR OPENER FIRE ALARM WORN/STROBE — — — — — — — — — — — — — — — — - - - - - - - - - - - - - - - - - - jSP SPEAKER JACK(WALL MOUNTED) ALARM KEYPAD FIRE PULL STATION SPEAKER JACK(SURFACE MOUNTED) SECU C A � EXIT SIGN AUDIO VOLUME CONTROL ALARM MOTION D LL- n EMERGENCY LIGHTING DOOR BELL ALARM DOOR CONTACT N1.PROVIDE HOMERUNS TO ALL P'HONE/DATA/TV CABLES 0 1OTES: 2.REVIEW ELECTRICAL DEVICE TYPE AND COLOR WITH ARCHITECTS BEFORE INSTALLATION OF FINISHED ELECTRICAL WORK 3,REVIEW LIGHTING FIXTURE SPIECIFICATIONS FOR BOX TYPE&LOCATION 4.REVIEW INTERIOR ELEVATIONS FOR LOCATIONS OF ALL EXPOSED ELECTRICAL WORK 5.PROVIDE CUTSHEETS OF SPECAL ELECTRICAL EQUIPT.:T-STATS,HRV CONTROLS,OUTLETS,DETECTORS,&CONTRACTOR SUPPLIED LIGHTING WATER SPIGOT 6.REVIEW TRANSFORMER LOCATFIONS FOR LOW VOLTAGE AND LED LIGHTING I 00 7.ALL LIGHT SWITCHES CENTERED AT 41"A.F.F.EXCEPT WHERE NOTED ............I . ..................... ..................................... .............................................................................................................................................. 8.ALL ELECTRICAL OUTLETS IN WASEBOARD EXCEPT WHERE NOTED L WP I n ` W oc O U N O r-------- ---- W BB I J '&04 Jai I I ,s c,C' •a�l"C "O �, s'� U MAIN BEDR�OM n { �` A, TV I 210 I I I p a r e. CD G LI � CIA C 4-1 —T I I I 4� � I i r--q I I I I I I I I I N I I I I I I I B -------------------------------- ---- -------- --------- ------- I j FB BB SHELVES SHELVES SHELVES B 0 1 m GFIG --FIC° 209 211 09A I 66 I ----+----- ------------ B I I I I - - B I BB BEDRbsOM BEDROOM 2114 \o LOSE BB BB I I 206A Lu 3 ALL I --4 212 I BB LBB I Q/r BB �T4 Cl SE I ' — I i HAILL . i 12A _ i ° 2 5 I � V J I BB --- --- I--- Ili ° CL EB BB I �BB I I I I II i BATH �- 213 BB FI I ELVES i r n H --------------------------------------------------- I ---- -------------------- I- --------- O II F�—i I I I i � BATH II ° 1 cy uj 207 I w I I I I r ^ I I I v I i rTH ' I I W � I BB 3 CL ° I I I I I I I ELECTRICAL SYMBOL KEY i STAIR HALL AE SYMBOL SWITCHES SYMBOL OUTLETS SYMBOL LIGHT FIXTURES i 200 DIN BB -- -- ------ I $ SWITCH DUPLEX RECEPTACLE OUTLET CEILING FIXTURE(SURFACE) iM SWITCAUNDRY DUPLEX RECEPTACLE OUTLET I BELO Q 3 THREE WAY SWITCH use W/TWO USB PORTS O CEILING FIXTURE(RECESSED) 2O4 DUPLEX RECEPTACLE OUTLET CEILING FIXTURE(RECESSED WALL I o 4 FOUR WAY SWITCH w WATERPROOF U ' WASHER) I DUPLEX RECEPTACLE OUTLET TO SkAI $D SWITCH W/DIIMMER cFlc W/GROUND FAULT INTERCEPT CIRCUIT WALL SCONCE i I I I $wP WATERPROOfF SWITCH HORIZONTALLY MOUNTED OUTLET IN eB ° UNDERCABINET LIGHTING i CL W D BASEBOARD o I $j JAMB ACTIVATED SWITCH QUADRUPLEX RECEPTACLE OUTLET r,� STEP LIGHT I w w w I DUPLEX RECEPTACLE OUTLET �y� EXTERIOR SPOTLIGHT(EAVE i I ° F . $u LIGHTED SWATCH FULL SWITCHED ( MOUNTED) j GFI I m DUPLEX RECEPTACLE OUTLET CEILING MOUNTED EXHAUST FAN If HALF SWITCHED i BB CL ET BATH I w DUPLEX SPECIAL PURPOSE I :: > u SYMBOL PANELS RECEPTACLE OUTLET CEILING PADDLE FAN coI ILL w l B >; ELECTRICAL PANEL RECESSED PICTURE LIGHT OUTLET ELECTRICAL SUB PANEL DUPLEX FLOOR OUTLET r CL + � o TELEPHONE PANEL QUADRUPLEX FLOOR OUTLET �►� DATA PANEL 1 TELEPHONE OUTLET,CAT-5 WIRE W/RJ11 SYMBOL DETECTORSIALARMS/CONTROLS PORT I I I DATA OUTLET,CAT-5 WIRE W/RJ45 PORT i BB 3 BB CABLE MODEIM SJ S SMOKE DETECTOR I C l 4-PORT NETWORK ROUTER COMBO PHONE&DATA OUTLETS,CAT-5 WIRE CARBON MONOXIDE DETECTOR WALL I I I >' O - W/RJ11 PORT&CAT-5 WIRE W/RJ45 PORT U 0 MOUNTED) " I I I / BEDROOM WIRELESS NETWORK I I it (� ® COMBO PHONE&DATA OUTLET HO HEAT DETECTOR I 202 ROUTER I I z fyl'; TV o COAXIAL CABLE JACK FOR TELEVISION OR TV I COMPUTER LT LOW TEMP DETECTOR I i COAXIAL CABLE JACK FOR BOTH SYMBOL FIRE ALARM SYSTEMS �' TELEVISION&COMPUTER 4 THERMOSTAT I I C ��FX FIRE EXTINGUISHER H SYMBOL AUDIO SYSTEMS 4 HUMIDISTAT SPRINKLER RECESSED O (RECESSED) HEAT RECOVERY VENTILATION CONTROLS I L— sF CEILING SPEAKERS HRV I I I I I U .: F FIRE ALARM HORN/STROBE f� � , N SPEAKER JACK(WALL MOUNTED) ALARM KEYPAD I { I r� I I is €: C) j U FIRE PULL STATION gp SPEAKER JACK(SURFACE MOUNTED) C 4 SECURITY CAMERA w II I . w A AUDIO VOLUME CONTROL q I ,..e E EXIT SIGN 4 ALARM MOTION DETECTOR I I I ,.�i �••,;� EM EMERGENCY LIGHTING DOOR BELL ALARM DOOR CONTACT I BB B NOTES: I BB - I I 1.PROVIDE HOMERUNS TO ALL PHONE/DATA/TV CABLES 2.REVIEW ELECTRICAL DEVICE-TYPE AND COLOR WITH ARCHITECTS BEFORE INSTALLATION OF FINISHED ELECTRICAL WORK j 3.REVIEW LIGHTING FIXTURE SPECIFICATIONS FOR BOX TYPE&LOCATION I 4.REVIEW INTERIOR ELEVATIONS FOR LOCATIONS OF ALL EXPOSED ELECTRICAL WORK j 5.PROVIDE CUTSHEETS OF SPECIAL ELECTRICAL EQUIPT.:T-STATS,HRV CONTROLS,OUTLETS,DETECTORS,&CONTRACTOR SUPPLIED LIGHTING I 6.REVIEW TRANSFORMER LOCATIONS FOR LOW VOLTAGE AND LED LIGHTING 7.ALL LIGHT SWITCHES CENTERED AT 41"A.F.F.EXCEPT WHERE NOTED j 8.ALL ELECTRICAL OUTLETS IN BASEBOARD EXCEPT WHERE NOTED • ----------------------------------------- 12'-51/2" 1 4" 4'-3 3/4" L. KID 26'-9 3/4" 23'-61/2" I I 1 '-3 314" I .�•�«twtet► i cCi' •.•s• FCj ® ' EQ.1 EQ.1 EQ.1 EQ.1 3'-11 1/2" T-9 314" T-9 3/4" T-11 1/2" EQ.3L, J Q.3 I �` o°"•. ': -j L -1 -1 -1 L -J L -1 L -1 L + -1 L -J L -1 L L + TF 107,UW io I jl I I •+trots <7 F DECK ABOVE I 84'0" i � u 22'-0318" 11'-11114" i 4 34'-67/8" 12'-111/2" '-6" I ,r 2 — — — �— — — — — — — — — — — N L 1 -1 �I L ' -1 L I o Q c -r r- A4.1 I I 11 7 ci ,r 1 Lo it i I I e'er. u., 9'-51/2" 12'-7" 3'-7114" 4'-8 5/8" 3'-71/4" i 29'-3" 1 - ,� U, 1'-6" I �•" 0 a r — 11 — - - - - - — — - - - - - - - — - — — — — o — — I c 2 N L a F o I 23'-3 3/4" - ;h, ;�. UP I l 'I 0 22'-9 3/4" o N I N I 1 cf 01 I O w 84' _ Izt O O o , in co f` BASEMENT-STORAGE I C� C� I 9'-103/4" RAISED HEARTH ABOVE & MECHANICAL. r I r — — — , HWH BOILER I f I F- f � I I I F -1 Fes - ---------------- _�- --�-- -=- _ -3=e - - -=�=---=- =- -=1= =I =- =- -_- - =�---=---=--=-3=- -�=--=---_--= --�==- -=- -- -E —----- -1-—_— ------ L -1 �, L 1 I Lt -i I i � J Lt J 7114" 1/4" BEAM ABOVE — I — STEEL LALLY O COLUMNS(TYP.) RAISED HEARTH ABOVE I I I � I 9'-01/2" 9'-4314" L 9" 10" 1'-8" 10'-2114" 10'-0" 10'-0" 10'-0" 10'-0"10114" 5'-21/4"� II 4 23/4 w 3T-0" 30'-31/2" 5'-10" 'L-2'W — — ` — 1011/4" ol T-41/2" EQ EQ EQ I - - ~ O — — BEAM ABOVE_ _ M I I r- I � L I 71.4 ------- - --! -- -- ------------t --4----------- -- -- I--------- v J ----------- =I=- =J —------- it - - — - - — - - - — -- -- -------- i -- Ir-- t------------fi-- t- N t- ;- --------- - i L —I— J L —I— J L -iIL -1 I7 I 1 0 III N I I 1 8'-2 3/°' i I T-9 3/8" T-9 3/8" T-9 3/8" I I 5'-10" _ - 1 A4.110 I I I I I VJ 2 III I I I I w �T - li I I I w I I 1 II II 1 III I I 1 III 2' $" _ I F —� N BEAM ABOVE o , PORCH ' v J � I I � _ ABOVE I I -- --I -- —_+ _--------- __ -- L — ---- -= 0 2 I= - -- ------ - - -- -------- - I r 31/2"' 0 11'-3"L 1 I J -3'= 31 - 1/2" L - - -J T-61/2" 1 1 r ao i i UP -m- -EQ w ¢ ¢ ¢ ¢ ¢ ¢ ¢ ` ELEIC.PANEL I ---IF-- 1 1 I V o 0 0 0 0 0 0 I 1 1 1 \ W ------- 1 1 I hWPI I I I I 1 I I I I \ w w 11 \ A A4.1 3 o M 14 RISERS @ 7.25" 12 TREADS @ 10" I I cn [emu u w z z aj o I I a O O cr 0 v 101/4" W N N N N N M iz CO N C) I W II A4.1 4 z v < UNEXCAVATED N LV CD N ' M N z W W � cal W � � a �' z Q m o L o a N N co A200 N O N Lo 74'-10" 9--2- v T AJ.0 -,k,--1--,V----------- --- ----------------------- I----- 14 EQ D4 LO - - - - - - - - - - - - - % 5 17 T-2'1/2"R 0. T-6 114"R.O. 3 0. T-2 1/2"R 0. 1/2" 4 M" 3 1/2"y 31 1/2" GRILL LPROM IE GAS F_ I A8.3 2 LINEIFOR c� 3 A4.0 ZD 1 FIR 7 PIT .0 WEST DECK EAST DECK 2 FR 3-1 111 �i1III1IIIIIIII1IIII 1iI'II -IIII -ILIIIIL_--�-IIII1I1IIIIIiIIIIiIiI1II IIIIIII�-1IIIIIIIIII I1IrIII III_IIIIIIIII iIiIII,iItI1III-II_MpoI03IIIIIIIiI1III1II II--i--_T o_ o--aa---"--12_-4 11 1- M_ SCREENED PORCF Fl 12 1 EQ /-1 1/2" 1 1/2,, EQ ('A4 iCwnotiN 22'-0 112" 1 l'-lil 1/4" 111-01/2' T- 1.R.O. 3'_61 "R.O. LT-61/4"R.O. Cioll '-7 1/4' 4'- 5/8" 3-7 it4 e- A A o EQ EQ 0: 4112" 67 5,IOn 0II �N\K - zt II II iI R.O. T- 1/4"R.O. .7111. 0 m _?01 T-9 314" 10.1 3-61/4"R.0 T-6 1/4' - ------ ------ L 12'- 112" -- 2 C-li DNI 01-51. �N I A 4'-6 1/2" A 1 ".4- 10----- --- ---- ---CK T------- LO rl I NJ (103) 12 181-00 1112" 5 1 V- 1/4" 20'-2 3/8' DW 2 - 1/2" -5 Iql 5 1/2" -13 - I I I I I IL__ n f////.1 1 1 1.11 . /,kill -1 ly, 33 F= - - - - - - 2'-0 112 J111114" 4'- 1/2" 30 ----------- co 9 L -i I STAGGERED 8.5 1 1 : i TUD� [A872 �_TRWy6E_ICIN(�_ 2 10, 1 1 5 A8.2 3 ITC HEN TV I - I I �q I I 1 1 5 A8.41 2 1 1 1 1 2s 0" (,9) 0' f 1 4 1 51 1 4 31 1 w: LI I OD : .-I I MICRO.-Il wo BEDROOM ...... 0 �CUBBY J N§ I I I- - - I I RFAMIS - ABOVE 0 WOOD --------------------------- A .2 01 11 0 A -ic 1/2",R.0 3/4N- E cli C14 \ I., TV ABOVE 2' 10 1/2"'R.( DW (i vy I I A9.? I I I I I I I I I :I1 I 128 1 - 1 1/21 1 4- 01 N� � � � r I I I I I 13 1 M I I I jv .4 2 OVENS 16 A8.5 14 c,,7, 15 5 _-j -*4 4L_ ------ 8 A8.5 6> I cl LL L GROOM 7 BATH rl 7 127 115 00 A8.2] 9 115A Ic:s I I F 8. . WOOD W D INNNNNN"'I TILE WOOD NA. I I 1 C)! T-2112"R.O. l'-J 9 1/2" 5'-2 1 A?R.O. tl-51 5112"I v-11 1/pN N T-1?314' 11 5'-5 5/8" 3' 31/2" N ON 2" 2" 51 .,/(1. ill 1 4 1-2' 4 4 zt7t__:�1/2"1 Lp LO - -1 1 q25F ------- -�t_--BAR- F 7 73/4 31t21- ­2 1/2' -3 i�T 14 1/2" IC- STORAGE lh Ili WEBOARD­_ _F % -7L C" 14AKE� 2 8.0 -1 \ cm cv 6'-8 1/4" 53/4 LO 1 1111 Vv A3.0 C f6 L----------- --------------------- AL OVE 7"R.O. 22---------------- ---- 1/2" 901/4' �71/8" �71/8" 9�1! 0 2'-3 314 5 1 6'-4 3/8" 10'-11/8" T-6 1/2" 4'-0" 4'-0" -5 .0 R 11 1A U-5 112' 5 11A, A3.1 �2 4n (7 c::p / ENTRY 4 A8.0 2 Q91 8 1 6 F1-0-1-1 3 8 3 314" 3 5/ WOOD (L. T-8 1/2"R.0 1 R. T-l' 101 2"R.O.L. 3-1 �-101 "R.0 'DN_ ------ "'IFAN R I I EQ 10 EQ ENTR PORCH Fl u 19 W V) 61 4'-1 /4' 3' 11/4" 7'\--V 3I/2A' [ 1 2- 1/2"t.-OO HVAC CONDENSERS - 3112'_ 6 co - 7 FIAIDR R % 4 El.11 > u < A m m m `HW T % F 3'-4 /4" 2'- < < 3 W 0 I I N, MUD OOM C-i - I % % u 1 6 5 AD ------4 1 1! cy�2 1 E U7 2 3j 2 10 LAUNDRY-' J 13 A8.0 11 2 ll'-6 3/41' 31/2 < 12 a STONE WALKWAY: - 2'- 1 1-I O"l 14 t_!Z. TILE 14'-0" 5 1/2"­ Lu C-4 Cl) -W L>Lj Vin.Q%' LLJ C13 cno % % 2l'-6 3/4 6 1/2" T-6 112" 16'.ON F------ '-51/2" 5 1/2" C, v) N 2 LO zz co T I l'-9 1/4" 11'-6 1/2" CD F ------------------------- A4�l --- -- -- I- I ------------- __T - 9---7------------------------- -i ItI r A I L__t__j STORAGE [C5 to SLAB SLOPE cn ZZ GARAG 104 01-1 tr) CD - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2 C) ------------------------------------ ------------- ---------------------- I A- co I 9 :z--1 (1 0) cli 0 4 rVIIII1101, L - ------ ---------------- ----42--0-- ------- ------it • N C) 3T-0" 32'-ON ON cv V 2' U) 84'-ON A3.1 62'-5" T-5" 9'-0. 3'-101/2" 7'-111/2" 3'-6112" 16'-11" 5'-61/2" 9'-0" 4'-0" EQ EQ 3'-61/2" A4.0 A4.0 A4.0 OF A4.0 1 2 5 v,.�.tVelttN�fP T-21/4"R.O. 4'-21M'R.O. " 3'-21/4'R.O.14, 4:13 I I � `� CD m STORAGE i t N '"@o �r^Itq 1 P10'�•'• N I p st;teat.. - W M IN BEDROOM " ; _ TV o f w t l , U3 210 21 '� I U6. O I WOOD -� I ^ L CV M 51/�"W Q c c C A4.1 _ - - - - I - -ao I I r, - . O I 1 w I 10 I I I � J , - � O i i 13A8.1011 i I z Iw �, 3'-61/2" 112" o w i � I _� 112" 3'-61/4"R.O. 3'-61/4"R.O. 1/2" 2'-5 3/4" 4'- 14" 3-3 3 ..� � I v 16'-0" 511/2" I 1/2" r � M � L - 1/2" 3'-61/4"R.O. I 3'-61I4"R.O. 1 " ` HE 2 N N IIII I / I \ � rn N I I - - - - - - - - - - - - - - - ' 1/2"R.0 "' - ----- " --- it S1/2" HELVES W HELVES �, _ ___._ ____ _ - DRAWERS DRAWER N 51/2" 5112" N 0 1 26 EAVE 112 _` _ 5114 BELOW BELOW - 14 EAVE - - - - - - - 31/2" d STORAGE 1 STORAGE HALL FLATC NG MAIN (BATH "' 5 MAIN CLOSET " `" N ------ --- ---- 211 1 NNN 1 209 "' 218 8 A8.10 6 209A FLATC G N TV SL PED CEILING-_ = TILE 6 A8.11 2 M°' WOOD 1 N " 7 W� ' SLOPED CEILING --------8,_ ("-------- --�_ 4 4 A8.1 2 1/2 n ----- 6' „-- -----------$--�" ------- ---4 0" BEDROOM I STUD WALL 1/4STAG6ERED "22 4'-11"R.O. 3 c rn , 1 w 214 I A8.11 10 A8.11 s 2'- /2"R 4 10 BEDROOM WOOD 9 ,_ n " - 13 A8.9 11 1 5112' 9 7- 51 2 3- 3 12 208 12 A8.12 10 _ - WOOD I 11 _ 2 - o STAGGERED 14'-31/2" 3 "HAEL `r 5'-21/2" "?_ - 15E' 1/2" STUD WALL w N L O 1 1 Woo - M N 111/2" 3"R.O. 10 1/4"2'-8 1/2" A 312 2 2 4 A8.9 2 - - 211 1 O 3 N " /2" 1�,-4„ 51 n 22 " 1= 6 -6" 51/2" N HALL .� `� I - 206 � 14'-11 112" 51/2" 2'-8" 112"�' i w z 1 - CLO IM I - I 66 1 � � 212, � 1 s � HALL N wooD , ^ d -- ---- ------- --- ---- --� - 5 0 20A8.12 18 I 205 "'+ SLOP CEILING I -- --- ---------------- '� _- 8 A8.1 i 2 6_ i 19 I o WOOD o � 1'r6 / " 2'- "= SLOPED CEILINGEl-j (V = 7 I BATH 121oCL - r ^ z 213 '-11`� 1l R.Q. v J J o I 31/2' - � N I TILE _ O 9 A8.7 7 2.- BATI- 2'_1 4" 31/2" i co ' 10 0 3 4 1 N L - - - - - - -- - - - - - - - - - - - - 207 ^ 1 I I I TILE - r - O _/I r--__ 2 UJI I PULL- I -J � N I : DOWN i /2"= 9'-13 " 751/7- to - - - - - o STAIR - -a ABOVE I 1'- 0"" 1' 8 2'-4 /4" .n A4.1 I i�, A8.12 I "I A8.9 6CY I Lu % , 5 12 11/2 I 7 PL� .� M 1 M (1 I {----58 l! 6'-11112" N_ o N W I Ln I �' 1 �, 20 -�1 `' 5'-1" p 1/2" STAIR-HALL _ N _ I o WOOD ��\ If st st 3 cl, 1 jCU TOM GATE DN �, - - 1 2'-4 /4" �12" w I LAU 8.7 2 I A (0 I _ 20 3 N � (�] TILES'-3 1 c� ►^�i w U _ O I st N 5o I v --i -3 � --i � --i -I 1'-W1/2 L - = U < N N I _ _ _ _ <0 tQ 4 201 �+ IIII �, I aJ � 1 _13 ' 2'- 112" N 51/2" °2 4' 7112" _`�' I '-1 _ 1/2" I O M 112" w 1 ° 203 9 1 o W z z 51/2" '-01 N4 A8.8 2 TILE 12 A8.8 10 I "' w o 2 6 _ - L3 N '-8" 11 � I 01 0 WOOD 11 5' 10 51 - N °O Ic 51/2" '-41/2" N 203 aD N N N N M v (V N 5 3/4" N I N - I GUTTERS A a M " a I -i -10 "R.0 STAGGERED = I 2 I� STUD WALL i " I I �M Il'-61/2" 51/2" w 1 w 16'-0" I 3'-61/2" Al % w i 10 O a O I I m ' Tv 77 c I BEDROOM 5 ; � I I z A4.1 I �� 51/2" 1 3'-61/2"I 202 8 A8.8 6 O z 00 I WOOD 7 i " �- I 140M. r- '"' I I � cn N 4o oo i i� , I °° O IT LO LAJ I I N I I u� �"' I I I � o, 3'-21 "R.O. 4'-21 "R.O. 3'-2IV"R.O. I a I I M EQ EQ L - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -� • v N O N Lf) 15'-91/2" 7'-71112" 3'-6112" 16'-11" 18'-6112" N till I I fit A4.0 ,?!0 /A4.0 5 SLOPE F- - - - - - - - - - - -- - - - - - - - - - - - SLOPE SLOPE -j 2F T- u u L < SLOPE SLOPE EXTERIOR EDGE OF FRAMING BELOW A4.1 4- T 14 SLOPE S F- - - - - - - - - - - - - - - - - - - - - - - - - - - - F - - - - - - - - - - - F- - - - - - - - - F - - - - - - - - - - - I I I I f I I I I SLOPE PE I I f V- SLOPE SLOPE -j L J - - - - - - L SLOPE I SLOPE SLOPE SLOPE I K 0 SLOPE i SLOPE SLOPE Q I n I l � l I I 1 I � � - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- VJ - SLOPE SLOPE SLOPE SLOPE L- - - - - - - - - - - - - - - - - - - - - - - - - - - -j 1 L _ - S PE \TSL61 PE A4.1 2 F GUTTER SLOPE SLOPE L SLOPE SLOPE U o ci 62 F V (SLOPE I I �A4.1 I L �- - - - � i a a W 0 0 CV E CN CN C4 C�l "�r �j --!22 ;:-- r-- SLOPE SLOPE i I I I I SLOPE I I A4.1 u n C", LL- - - - i a CD CD 0 SLOPE L- - - - - - - - - - - -- - - - - - - - - - - -j a. SLOPE O Cl) A203 Lo (J�,• • / ` % it♦ v. . C is 9ii vj •.� _ ? v L r�r♦ark 0: IIiE �}a t��,`e � / :.? A6.4 J 2 J U ^-, U r_ STONE STONE ry L VENEER VENEER C 7 IT � r-- ., :J ^ M, M, I i I 0 0Lj 0 ~ N � CV ate- (V O O O ti ti SECOND FL SUBFL 3 -23FL o 0 o W N n FIRST FL SUBFL (� H 22'-8"' NEER I —j STONE L-1 � VENEER ILLcn � uu T.O. SLAB — — �NORTH-ESE-VAT-SON — — — — — — — — — — — — — — — — — — — 14'-2„ PL� 1/4"= 1'-0" A6.3 7 w w V J � A STONE VENEER V Cl 0 0 0 0 0 0 q9, x s V A cn a a a O FLASHING o /' \ / \ / \ / \ ILI O w ~ N sY N / N N co N � � A6.0 0 0 ti SECOND FL SUBFL — — — — — — — — — — — 33'SUB 0 I — - - — — — — — — — — — it ~ u 0 o LLJ CV a o z x co Bo w O_ S Qo FIRST FL SUBFL W Q Z ►-i z w STONE VENEER a N N N ch WEST ELEVATION 01 Lo 11 1- 1/4 _- 1 011 00 10"0 CONCRETE PIER 6'--8 7/16" 6'8 7/16' 6'8 7/16" 6'8 7/16" T 10 31116' 74 0 3/16" 7'10 3/16" 3'11" 8'-4 3/4" 1 ON 24"0 BELLED NO FOOTING, TYP.U.N.O. 1v' 1 (� n O v 4'(0"x4'-0 x8"PRECAST PAD PER SUPERIOR QJ QJ QJ QJ I QJ QJ QJ I QJ QJ QJ I QJ QJ QJ I QJ WALLS FASTENED TO FOUNDATION FOOTER _ BEAM.PROVIDE C.I.P THREADED ROD AND I I I ALIGN WITH PORCH FRAMING ABOVE I I F COUPLER IN WALL,REFER TO 5/S3.1 PROVIDE FROST PROTECTION AT ABOVE N GRADE WALL PER"SUPERIOR WALLS' \` / \`J/ RECOMMENDATIONS.SEE 4/S3.1 12'11 1/2" 2'6" a� O J QJ I Q I QJ I 3 QJ QJ I 3'-0"x3'-0"x6"PRECAST PAD PER SUPERIOR V) OPENING IN WALL PANEL FOR �h� �h� WALLS FASTENED TO FOUNDATION FOOTER r d�- WIINDOW,SEE ARCH.PLANS FOR I I I S3.2 `' N' BEAM.PROVIDE C.I.P THREADED ROD AND S12ZE AND LOCATION OP:NING IN WALL PANEL FOR /\ COUPLER IN WALL,REFER TO 5/S3.1 BA EMENTDOOR, SEE ARCH. / I r -------- ----- ------I � WALL LOAD. Pi ANS FOR SIZE AND LOCATION ( ) I ---- -- ----- ------- 1. i <. ,oG 1 ,oG ,oG ,o e / J,��\ ------�\ I J��.\ 2 \Q '/ QJ Q�j 3 QJ QJ ,oG ,oG I II _ �-- ------ --------� I"I -- S3.1 �s �s n--- ---- G S3.2 �'` `L� 0� S3.2 6� 66 �� $�,� L- I I I I �pJ�Q' Cq ¢�Ar- -7 ,o ,-r--- Q� � - Q�►� AL LOAD: L------ - --- ----- ----I I ��� -----�\ ��� I----- - ----- ----- - ------ -- ------- ------- ------J j r .92KLF --- ------- ------ -- ------- -- �� ��1 --- ---------- -- - ---- -- ---- -----.----- -------- ----- --- - -- \ I p -- O� J WALL LOAD: I -� I � � --- ----- �� ---------- ---- - - ------------------ 1.30 KLF _a �-�,,. � r-J WALL-LQAD:• --� --- -- B MLOAD. 1.10K L-- ---J Q ` QQ BEAM LOAD):3.87K Q 5 \ c`'sj Q g J 0.75KLF g� J�ti� F,o J J6��\ _ r 2 `� ASSOCIATES \' \' I I I S3.1 STRUCTURAL ENGINEERS a I 7'--81/2" 3'--6" 11'- 1 1V 4314" Z-71 " 6'-0" 26'-2 7/8' 1 1 I 860 Walnut Street 2 0"x4'-0x8"PRECAST PAD PER SUPERIOR BEAM :2.20 S3.1 WALLS FASTENED TO FOUNDATION FOOTER 3'-0"x3'-0'x1'-0"SPREAD OPENING IN WALL PANEL FOR I I Sim ,o I I BEAM.PROVIDE C.I.P THREADED ROD AND FOOTINGW/345BARS WINDOW,SEE ARCH.PLANS FOR I I 1 Newton Centre,tel 02459 a 4"CONCRETE SLAB ON GRADE EACH WAY BTM SIZE AND LOCATION 617.244.17 2 tel M 617.244.173?_ fax COUPLER IN WALL,REFER TO 5/S3.1 " W/6x6-W1.4xW1.4 WWF I S3.2 6ss I I " I 5-3 Z I I www.siegelassociates.com CID BEAM LOAD:2.87 K 4-9 1/4 N i I, I I �, I I I I I I I I I I I I r------- 11 L--J L� rJ L--J L--J L----J L J L J I I W BEAM LOAD:2.42 K I I I I CMU CHIMNEY,DIMENSIONS I I I I 4'0 ic4'-0"x8"PRECAST PAD PER SUPERIOR I I I PER ARCH PLAN W I I I I I WALLS FASTENED TO FOUNDATION FOOTER I ~J 1 1- 1 2'Xx2'0"x1'0"SPREAD I I BEAM.PROVIDE C.I.P THREADED ROD AND I I I FOOTING W/245 BARS L_ _ __ _J COUPLER IN WALL,REFER TO 5/S3.104 1 I I EACH WAY BTM, TYP .0. w v-, " I I I `\Zp �Q 1* 12 T OOTING 12"THICK 1 J X'0 x3'0"x1'0"SPREAD FOOTING I WALL LOAD: 1 i CM MNEY, SIONS FOOTING W/345 BARS I I I 0.'75 KLF eAG i i �U' 3T-0" R ARC EACH WAY BTM BEAM LOAD:2.21 K L----- I I BEAM LOAD:0.50 K v, BEAM LOAD:0.81 K .o I I �- 3'-0"x3'-0"x6"PRECAST PAD PER SUPERIOR � 2 WAL LOAD: WAL LOAD: __ J �Q• GJQ C,JQ GJQ GJQ G L J O 111oa -- �. �. �. ----- �----- I WALLS FASTENED TO FOUNDATION FOOTER `� Z3 0.75 KLF 1.30 KLF F \ _ _ r F I� L------------ - --------------------- - -----------------J QJ I I -- I L-J L- 1 ' 1 1 COUPLER IN WALL REFER TO 5/S3.1 BEAM.PROVIDE C.l.P THREADED ROD AND I I -------------=--� - - ------ ------ --- - ------�-- -- 1 F------------- -------------- -------- ------- --- ---------1 I I I I I I I I r- I---- I I L-- -� I A� I ,off rT�1 \ �'• S3.1 r I - _==-_---- 4"-0"x4'-0"x8"PRECAST P)AD PER SUPERIOR I I 1 I 1 I MIALLS FASTENED TO FOUNDATION FOOTER BEAM LOAD:2.20 K BEAM LOAD:1.10 K B AM LOAD:8.20 K j 2'-6 x2'-6"x1'0";SPREAD I I 1 QJV�3'� H BEAM.PROVIDE C.I.P THRREADED ROD AND I FOOTING W/345 BARS 1 I 4'-0"x4'--0"x8"PRECAST PAD PER SUPERIOR �I.� COUPLER IN WALL,REFER TO 5/S3.1 12 1 1 H Y I I 5'--10" 9'--2" WALS FASTENED TO FOUNDATION FOOTER S3.1 I I ; -' I I BEAM.PROVIDE C.I.P THREADED ROD AND I i I Q JQ JQ JQ I BEAM LOAD:4.26 K COUPLER IN WALL REFER TO 5/S3.1 101/4" E SUPE WALS 3 z I I 10"DEEP CRUSHED STONE � �G �Q �G �G { FOOTING BELOW x PRECA T FOUNDATION WAL I I Q a w .- FOUNDATION WALL I I w z "_ Q I I r - r ( © ) I I w JCn 1 1 a ( 3 I I THREADED ROD TO I I I I I A I I � � z � I I _J WALL LOAD: } I I ISOLATED FOUNDATION DESIGN OPTION I 3 3 � L__�J FOUNDATIOAV L---J 1.30 KLF I I I 4 .oG ISOLATED SPREAD FOOTINGS MAY BE REPLACED WITH"SUPERIOR WALL" BEAM LOAD:2.0 I i I � w REFER TO 7//S3.2 U_ a I S3.2 V PRECAST COLUMN PADS AS FOLLOWS. I I I o X i .,_I I J W WALL LOAD: i 1 I Q \ -ALL 2'-0"x2'-0"x1'-0"SPREAD FOOTINGS:2'-0"x2'-0"x41/2""SUPERIOR WALL" 0.40 KLF I L - - - - I I 5'--10"NA I V PRECAST COLUMN PAD W/8"DEEP CRUSHED STONE BELOW PAD BASE I I I I 1 \ -ALL 2'6"x2'-6"x1'0"SPREAD FOOTINGS:3'0"x3'-0"x6""SUPERIOR WALL' - --- --- - - `c I I I I I I 1 FOUNDATION SUPPORTING SHEAR PRECAST COLUMN PAD W/8"DEEP CRUSHED STONE BELOW PAD BASE I --771--_---ALL 3'0"x3'-0"x1'-0"SPREAD FOOTINGS:3'0"x3'0"x6""SUPERIOR WAL" I 3 I I < I WALL ABOVE Tf0 BE DESIGNED FOR o 2 w W I u- - PRECAST COLUMN PAD W/8"DEEP CRUSHED STONE BELOW PAD BASE 1 I S3.1 I I I MINIMUM 20001PLF(ASD)SHEAR LOAD o o L----------1 II I : I az w � I I pP�y BEAM LOAD:3.10 K ,o I 101/4'WIDE SoUPERIOR WALLS = o C/) Q 1 I I A -CHIMNEY MASS FOOTINGS.SUPERIOR WALL PRECAST FROST WALLS MAY e CO ti I I ( �o X►PRECAST FOUNDATION WALL BEAM LOAD:2.31 K w � CD I I BE USED TO SUPPORT CHIMNEY MASSES.DETAILS AND INSTALLATION TO I I I ,off' I L- CO z �o I I 1 F- BE SPECIFIED BY SUPERIOR WALLS. I i Q E2 I `- TOP OF FOUNDATION WALL I r- -----T --h\--1 �, w w `1 I \ W n cwn I I I I L_-� pJ V oc U_ a J Q• J L J Q UNSUPPORTED AT STAIR a �• I V ,- " " I I I I I r \Z` G. I o r----- G F cn OPENING. SUPERIOR WALLS TO ( 1 I I QJ�� I x I QJ I I QJ27 PROVIDE SILL REINFORCEMENT I I I �\ --1 �'�\ L----- ~ w o AS REQUIRED J I I J o I I I J�pO --- ---------- /P N WALL LOAD: I I ( JQQ I 1 (� o 0 II I SLAB SHELF PER L I II L------� 6"TOP OF WAL 1.30 KLF �� I I I yea `� I I 1 SUPERIOR WALLS DESIGN STEM THICKNESS PER I 4'-0"x4'--0"x8"PRECAST PAD PER SUPERIOR J` �Q I o 0 SUPERIOR WALLS DESIGN I I Q I I WALLS FASTENED TO FOUNDATION FOOTER 101/4"WIDE SUPERIOR WALLS I I I 2'-6"x2'6"x1'0"SPREAD BEAM.PROVIDE C.I.P THREADED ROD AND I I I PRECAST FOUNDATION WALL FOOTING W/345 BARS COUPLER 1N WALL,REFER TO 5/S3.1 1 1 I 4'-0'x4'0"x8"PRECAST PAD PER SUPERIOR I I I EACH WAY BTM Q Q I I I J WALLS FASTENED TO FOUNDATION FOOTER o BEAM.PROVIDE C.I.P THREADED ROD AND _ I COUPLER IN WALL,REFER TO 5/S3.1 S3.1 WALL LOAD: I I I I I CRUSHED STONE FOOTING ►I I I z 0.40 KLF I I I I I I PER"SUPERIOR WALLS" I I II I I I I I RECOMMENDATIONS I II Q V L---J I I I U II I I II n- 1I I I I WALL LOAD: z I I I I I 1.30 KLF � C 4'C,ONCRETE SLAB ON GRADE `v F- W I I I W/6x6-W1.4xW1.4 WWF I I I 6 Q N I I I (PIT(CHED FOR DRAINAGE-SEE Q0 I I I ARCH DWGS) 11 1 S3.1 `� I I I 2'-6"x2'-6"x1'--0"SPREAD I I I W � Z II I FOOTING I II Q 4'0"x4'-0"x8"PRECAST PAD PER pp SUPERIOR WALLS FASTENED I I I �GJQ �GJQ O TO FOUNDATION FOOTER I I I I I I QJ glad BEAM.PROVIDE C.I.P I I I S7 I I HAUNCH CONCRETE SLAB I I I I I THREADED ROD AND COUPLER IN WALL,REFER TO 8/S3.1 I I OVER LLOWER FOUNDATION I I I WALL AI T DOOR OPENINGS I 1 " " " �w•-�:f,,�,;a,�` i I I .\ 4-0 x4-0 x8 PRECAST PAD PER SUPERIOR \. -J '� '� L-- WALL LOAD: G O �• WALLS FASTENED TO FOUNDATION FOOTER J YS3-_1 J I L 750 KLF � M �� j i Qd��G COUPLER OINI WALL,REFER TO8D 30D AND FOUNDATION PLAN I Q Q Q 'Q I Scale: 1/4"= 1'-0�� i t ------------- ------- F------------------- ------------- 1 414" ,NJ 3'-0� �, 2'-6" (, 20'-0' I Z.O. I 2-2x8 L U J 00 r O .0 6 6 6 ,o QJ AG QJ .oG QJ .oG CO! L ;o O J '0 N j r cov N STAIR DOWN L N W J W 1r 1r 1r 1r r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r -lr r 1r -lr 1r 1r 1 1r 1r 1r 1r 1r 1r 1r 1r 1r Q 2x6 HORIZONTAL BRACE TO B12 PT -2x12 13± ONG, ONT UO B 23 P 3-2x 2, 13' LON ,CO INU S 1 PT -2x1 23 ONG, CONT NUO 127 T 3-2 2, 12 LO CO TINU US I _ UNDERSIDE OF JOISTS, cn ( ► 6x6 PT DIAGONAL T 0 U FASTEN TO EACH JOISTS W/ +6 ,o o KNEE BRACES, TYP. •..L G 6, I 6 SEE 6/S3.2 u (2)'/.'0 x 4"LONG FRAMING A Q �� Q ,o z ( 1 SCREWS, TYP. i � / " �= 6+ �./ �-+ W 6�6 I � PT 12 @ 16"0. i o PT 2xi2 16" .C. i PT 2 12 @ 6 0. . J PT 2 12 @ 16"0. . o I Q� O [� D CKJOISTS DECK,fOISTS' FZ'- i DECK J(ISTS - JOISTS " p! 6x6 PT DIAGONAL i z zo I D CK CD ( w KNEE BRACES, TYP. o QsG�' o y0 G� i \ o SEE 6/S3.2zo QP/ ` 4-)cli d0- -H % Z QJ%, 4�j DTT2Z HOLDOWN TOmm N, I .—r FLOOR JOIST,4 LOCATIONS Aj 6' i Q I 3 Q Q COORDINATE OPENING 6f6, ( c v 3.2 a I O Ln REQUIREMENTS WITH 1 N � a Q SIM SON U210 ACE \ QJ J L J L TK �' DTT2Z HOEDOWN TO cl� SUPERIOR WALLS, TYP. I a a co MO NTH NGE , TYP. _ITj, LEDGER J J L J L LJ FLOOR JOIST,4 LOCATIONS J P 2x12 EDG R J J J J J J J J J J O JL (3 JL JL JL JL O Q O O Q G �y STAIR DO N Gj `Z` \ \ \� OJ N ry �yaG $3.1 OHO 'Q J�J L QJ� Q � QJ � QJ �G J L / PT 2x 2 LE GER QJ +p1m JL JL JL JL JL -i JL JL JL L JL JL JL AL J/1.L JL JL JL J JL JL / I 1r 1r 1r — — 1 r 1r — — — OJ SEE fAIL 3 3.2 OR L D 8G FAS CAT I NS,ENIN P.AT DTT ZHO o To I ASSOCIATES Q A I L Q 2x1 @ 116 O.C. I FLO R JOI T,4 OCAT ONS STRUCTURALENGINEERS �y0cj I I SIM SON HUS .50/10 860 Walnut Street 2 `" FA MO NTH NGE ca COORDINATE OPENING Newton Centre,MA 02459 S3.1 I G o 6 N RET SLAB I SIM SON U210 ACE SIM SON S21 3 FA E REQUIREMENTS WITH 617.244.1612 tel AG SI PSO HU61 FAC °p B R E CH A@Y 12 0 C I J MO NT H NGE , TYP. MO T HA GER ( o SUPERIOR WALLS TYP. 617.244.1732 fax M UNT ANG MPS NHU 410E CE Q " 6"CONCRETE SLAB www.siegelassociates.com L J L 5 9'."L L OUN HAN ER I HEARTH W/#4 @ 12"0.C. G I I BARS EACH WAY $ - MPS N LU 210-3 ACE I QJ HAN ERB 01 3 9'."L L, 18' LON ,CO TINU US B10 3-9' LVLJOUN7 0'±L NG, ONTI UOU 8 09 3- '/,"L ,20)' LON CON INUO S 8 1 3-9' "LVL, 0±L NG, ONTI UOUJL JL -J LJL JL JL JL JL JL JL JL JL JL JL JL JL JL JL JL JL JL JL JL JL JL L JL JL JL JL JL JL JL L JL JL JL JL JL L JL JL JL JL JL JL JL JL JL JL L J1L JL JL 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r -7 1r 1r 1r r 7- 7- 7- 1r -I 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r I I I ALIGN C LUM WIT WA \G S3 2 I I ABOVE. ROV E 5" IN.B ARIN � I LL _ a, I �\� I I QJ kao g o ( MASONRY CHIMNEY z 1r 1r 1r 1 J I 5 M Q O 104 -2x1 o J ch N NYC MNE Q c,; SIM SON HUS .50/10 Si m Q an o I FA MO NTH NGE L G Ca 2x11 @ 116 O.C. r D 14 2 2x10 I � I B 15 31%-L 6' LON ,CO INU/ S I I B11 3-9 ."LVL 22± ONG ONTNUO L JL JL JL -i J JL JL JL JL L JL JL JL JL JL JL JL JL JL JL JL JL JL JL r 1r 1r 1r 1r 1 1r 1r 1r 1r r r 1r 1r 1r 1r 1r 1r -IFU 1r 1r 1r 1r 1r 1r 1r Q QJ S3.1 0 QJ� QJ J ,off AG " ��' G I SOG ,oG yOG AG F-�i <<, 91 Q PT 2x12 LEDGER r 1 L J AG H 2x10 16" .C. r 4 1 W (T 12 � � CONCEALED HANGER TO 2x12 PT LEDGER, S3.1 ,o L w v o TYP.EACH END o a SEE DETAIL 4/S3.2 FOR B11 3-9 "LVL 16'± ONG, ONT UO)U 811 3-9' "LVL, 16'±L NG, ONTI UOU N N w LEDGER FASTENING AT J L J L J L J L J L J L J L J L J L J L —I L— J L 1L _J L— J L 1.L —J L— J L J.l _J L_ J L f— [� J ^ BEAM LOCATIONS, TYP. 1 r 1 r 1 r 1 r 1 r {J TT' —1 r— 1 Tr —i r— 1 "1T —r r— 1 'IT r— 1 r SIMPSON LUS210-3 FACE MOUNT HANGER Q ,I I l�, L QJ JII I F V SiMPSOVHHLS5.50110 PT 2x12 LEDGER A, cl' I FICE M UNT qANGi-R I ol1 - N A I ml 'I A G y I 2x @ 1 "o.C. G I OJ W U)N - - - - - QJ v� cr- z Ld Qv Qv N N J H Z \ Q TOP OF FOUNDATION WALL Q`�\�0 A o 0 UNSUPPORTED AT STAIR OPENING. "SUPERIOR WALLS"TO PROVIDE SILL REINFORCEMENT AS REQUIRED ,ZOJ �\ o 6 vGJQ �GJQ QJ QJ _ I S3.1 `— z I I � W U SLAB ON GRADE (SEE FDN PLAN) O W 6 N Q z n Q QJ� 7 /7 yoG z9 \p S3. 2x EAVE RAFTER CUT TO CURVE(MIN.31/2"DEPTH)@ 16"0.C. U) 00 24 JOISTS @ 16"0.C., TIP. J DOUBLE UP JOISTS BENEATH O G Q t 1 DORMER HEADER POSTS cV0 ill, I ABOVE, TYP. 2x LEDER H 12 �LEDJER L W I I i i _i i_ i I W --- - -B2fTl 3f9-LVL B218 3-9%"LV f9 -�7"LV - �(5 a ��� O U J L J L J L U O (n r r 1r - C)io O U W ——— V zi� I I I o o = -�O = J L J L J L U — a 1 r r c1� 1 r — O• -2 2 J �' V n 1r0 _ U ITS /� U/ [(. O � f - J L J L J L V� W W tJ , r O -p� ' r r r c� O - LLL 0 DECK BELOW ry DECK BELOW a /�� w w QJ �� w W COO) �, LU WLL O lJ - J J J L J L J -f• J - Q co cV N o O O O O 2- 1O x cx Q !? x O N L tp j L Cp L CO N W` N N O W --- r r r --- N w N o rn o rn o rn o OVERFRAME K`• ^ L L r ;..� L0 Or N ^ r N N -I x i $ r. CS16 COIL STRAP(36"MIN.) — �6 N N N _ __ 'L�6 'L�6 HEADER;REFER TO 2x EAVE RAFTER CUT TO CURVE(MIN.3112 DEPTH)@ 16 0.C. ——— J L J L J L 2 y3+ ROOF FRAMING PLAN , r , r SIMPSON 210 FACE r SAVE RAFTERS BLOCK BETWEEN FLOOR JOISTS AT RAFTER LOCATIONS,2 BAYS MIN.FASTEN 2x4 JOISTS @ 16"0.C., TYP. 2- x10 J L J L MOUNT HA GER TYPJ L I I SHEATHING TO BLOCKING WITH 8d NAILS 1 t t I I - - I" �1,`1� , r r r I I CO 2X 2 @ 6"0. Q I AT 4"0.C., TYP.AT GAMBREL FRAMING ��?fi � I I I - I I I I I I I ;L I I �'� " 6 RAFT RS `v I Igl �22�0" �y�f I I I I I I I I ¢x12 &DGE HIG I I 35'1 LE GER IG 4 p p o I2x4 L DGE LO I I I I I lF 12 DGE �t I L JL JL JL I � � 4 ; � ; � I&LO- - - - - - - F'- 06' 6 -18"LVL , 2 5 9% LVL B214 -9%"L L B213 3-9/:"LVL I I I B209 13-16"UV LOW 'r I I I4 I s�2-2x6 STUD FASTENED TO J L G , IJ L f 1 1 I I p , IFL J L J J L 22'-0 ADJACENT POST W/ r ,5, �, AFRAMING SCREWS co oG III I I I I III 1 III11 $cO 1 QJ�1cO I I u? �'\ G "' 6 d ASSOCIATES JL JL J ? � JL '� III �J. G L I it I I I JLI III I 1 Irr , rSTRUCTURAL ENGINEERS ao r e � r � G U BLOCKING BELOW CS16 III >> BLOCK BENEATH DORMER 9 J L L J L J L J F- J L WALLSPARALLELTO 860 Walnut Street � 1 r J r 1 r 1 r 1 r 1 r �j o " 4 N \ L� ,ZO I CS16 COIL ST ( 6"MIN.) O FRAMING, TYP. Newton Centre,MA 02459 N CS14 COIL STRAP(36 MIN.), m L `max J L J L \ L J L p BETWEEN B237 AND SHEAR 1p -I r r r r x _ .- 617.244.1612tel SHEAR WALL ABOVE'.BLOCK N WALL TOP PLATE ��6' \ \ Q `` ci M aU 617.244.1732 fax �y L \ I� L J L v J L III J L BETWEEN JOISTS FLOW J L , r ( r � 0 , r I I , r , r _ — W www.siegelassociates.com a. aS �\\I\ U �J L U L U �J L U JJ L I JJ L U JJ L U 0 MASONRY CHIMNEY 2_2x8 \ r 1 r r o 00 J 1 r p J 1 r r _ \ io io �o 00 x co ao `co io AG - N .-. co e- t-- �„�r C7 J L a•. (") L •- ^J N ^ J L J L ^J L a•- V r r r Z REF TO ROOF FRAMING PLAN \� � o, r � o r � M, B233 4-7'."LVL � �* m I I � co co w 6' Q N N J L N N J L N N J L N N J L N I N J L N N J L N U_ w \ r I7 r r FIELD DRILL HOLE FOR � � r (I I , r r 8208 - 8 zO \ J L J L PLUMBING.MAX 3"DIA. Q O J L J L J J � w U W 1 r 1 r- 1 r \ ' 1 r SIMPSON LUS2 -3 FACE r HOLE CENTERED IN ov W w O 1� y J L L MOUNT HANGS J L BEAM HEIGHT J 2-2X8 L L N , r (� r G � � r SIMPSON LUS28 2 FACE r `�' N� U ` jj,,' 2-2X8 J L J L I I I L J L N :��V J L I J L MOUNT HANGS J L ^ W r r r SIMPSON U28 FACE I Il r G r r , r SIMPSON LUS28 3 FACE " MOUNT HANGER, TYP. I iO MOUNT HANGE I M -i • � L J L i L L J L GJ L J L J W CS14 COIL STRAP(36 MIN.), m r r 1 r 1 ; r r _- BETWEEN 6237 AND SHEAR M \ B234 3-2X8 r B235 3-2x8 AG I x WALL TOP PLATE L \ J L L J L J L J L — -- _- N r Ij \ I r I i r I I, r , r �O , r , r B208 - 8- c+• o N m L K J1 J L IJ L J L J L I A J L L ,Q r 1 r 1 r , r 1 r 0 0 1 r 1 r m — O \' \� \!\ 1, I I I I qti� I `t'2� I I III I �� I rb I I 1$ /4 �� �+ L 3- J I I R� I ''� I I I I v?, I i� MASONRY CHIMNEY G L \I\ , I I I J L I Y I I 6' I L I I I I 1 L 3 T �' J C ] L r 1 r r 1 r 1 r 1 r 1 r V J 13-2 8 I 1 3-2x8 B723 319%"LVL I 1 ' B 24I 3- x10 J L B225 3-16"LVL ' G� 1 3-248 1r 1r 1r -1 r- 1r 1r I I I I I I 2X12 LEDGE - - - ,ZOJJ'� 3 ��Q I �, 0 12L GE IHIG I I I 1 i p J� tia 3 1 2x12 EDG HI " 2X4, EDG LO - r� 6 \ I 2x4 L DGE ILOW I I I I \ 6, _ _ �i � 1 _ _ _ �o I 6I I I I J 6 � � 3�ti __ _ __ I I I I I w 1 L- I Q Q � --I I t I -- I I -- G� PL� 2x SAVE RAFTER CUT TO CURVE(MIN.31/2"DEPTH)@ 16"0.C. ? x10 16" .C. —————— —— HEADER;REFER TO _ _ _ �' CI) ROOF FRAMING PLAN 2x4 JOISTS @ 16"0.C., TYP. -"' _—— _— J � OVERFRAME - - _N - - BLOCK DIAPHAGM ALONG N SI PSO LU21 FAC -_ 2-2x CONT. STRUCT FASCIA, d)----- M UNT ANG R TY . � k v) BEVELED TO ROOF SLOPE, PANEL EDGES.NAIL 1 - - - - - - -� o �- SHEATHING TO BLOCKING � J ,�� N Q ___ m _ TYP.AROUND EAVE LINE WITH 8d NAILS AT 6"O.C. S3.4cl� _ _ 31 _ _ _"' O o--- - cD - I W, 9, 0 J L J L J L J L 2x4 S UD 8 ARIN WAL BEL W F.- _ �¢ N co OVERFRAME B226 ;3-2X10 e----- -_ AA/1 N CO CY k U F•1 - - w V - _- V FASTEN 2-2x6 TO 4-2x6 POST WITH 6" o v, v o S -6 - LONG TIMBERLOK SCREWS AT 12"O.C. J OP G N - (MIN. 10 SCREWS) -`v - BLOCK BENEATH DORMER J " F- -- - -- WALLS PARALLEL TO A R J 2x 0@ 1 0.C _ Q c i � FRAMING, TYPri . �f J BLO KBE WEE JOIS SAT — - - a J2x6 STUD BEARIN SHE RWA L PE 4/S3. . - _ �- CIO, W w �G WALL.BELOW CO INUE BLOC ING BAY MIN. ch w -- o � `" td BEYOND E D OF SHEA WA - - - N OJT mw v __ _ ___ w o w �� J - �, - p" �p�� X6 S UD B RIN WAL BEL W - - -- ;L�6 ti O W. mJ \-- - -- -- Q 1 N N V CD CD �\ CN 22-3 6!y 2-2x6 STUD FASTENED TO o 1 -' ��6 y _ ADJACENT POST W/ A Q rn - �pT�� FRAMING SCREWS o 0 DOUBLE UP JOISTS BENEATH Cn 'm 10 Q.16"0. - -� DORMER HEADER POSTS ABOVE, TYP. C D SHEAR WALL ABOVE.BLOCK __ _ _ _ _ _ 3 v Z BETWEEN JOISTS BELOW 1p _ o — - P J 8 7 3- Y4"L 24'±LON CON INUO S �� Q I I �L- -jL JL JL JL JL JL JL J JL JL JL '�Fm N � � S3.4 � �- LJ- J 1r 1r 1r 1r 1r 1r 1r -1 r- r 1r -I r- 1r 1r 1r 1r 1r 1r ---• W \ r- �J � O ?* M U W \ t Fi) � Q N BLOCK BETWEEN FLOOR JOISTS AT G 10 16"0. . - - - __-- o Z Q0 RAFTER LOCATIONS, 2 BAYS MIN.FASTEN _ N 0 Z SHEATHING TO BLOCKING WITH 8d NAILS p,_ _ - - - ____ W U Z AT 4"O.C., TYP.AT GAMBREL FRAMING an -� ti W pq Cf) J - - -- J w ►-+ C� � w J �G G Q N ——� W 0 W J p JL— J L JL JL 28 1"L ILL L JL J L 4.1 1r 1r 1r "7r 1r 1r 1r jkDG 1r1r 1r 1r 1r 1r 1r i, phUt•.-� �`x2X12N. /C'el AP SECOND FLOOR FRAMING PLAN BUILD OUT WALL CORNER W/2-2x6 G� 02 6 '0 °" �OX'2 @ '6"O.C. Scale: 1/4"= 1-O" TO POSITION HOLDOWN AWAY 3 R TES FROM SUPERIOR WALL Lu3-2x8 FOUNDATION EDGE 10'0 �' GElJERAL CONDITIONS STRUCTURAL STEEL 20. UNLESS ANOTHER CONNECTOR IS CALLED OUT,PROVIDE ONE SIMPSON A35 FRAMING POST LEGEND SHEARWALL NOTES 00 ANCHOR AT EACH RAFTER/RIDGE BEAM INTERSECTION,AND TWO WHEN RAFTERS ARE �- O 1. ALL WORK SHALL COMPLY WITH THE INTERNATIONAL RESIDENTIAL CODE,2018 EDITION 1. STRUCTURAL STEEL DESIGN,DETAILING,FABRICATION AND ERECTION SHALL DOUBLED OR TRIPLED(ONE EACH SIDE). AS AMENDED BY THE MEW YORK STATE BUILDING CODE,2020 EDITION. CONFORM TO THE FOLLOWING: 21. CONTRACTOR SHALL CAREFULLY COORDINATE THE WORK OF ALL TRADES TO MINIMIZE SUPPORT UP ID V O 2. THE CONTRACTOR SHALL CAREFULLY VERIFY ALL DIMENSIONS AND CONDITIONS IN A. AMERICAN INSTITUTE OF STEEL CONSTRUCTION(RISC)SPECIFICATION FOR THE NEED FOR CUTS AND BORE HOLES IN FRAMING LUMBER.IN GIRDERS,BEAMS,OR PU POST UP THE FIELD PRIOR TO COMMENCEMENT OF THE WORK SIEGEL ASSOCIATES,INC.(SAI) STRUCTURAL STEEL FOR BUILDINGS,CURRENT EDITION. JOISTS,CUTS AND BORE HOLES SHALL NOT BE DEEPER THAN 1/5 THE MEMBER DEPTH CU COLUMN UP 1. SHEARWALLS CONSTRUCTION: W '� SHALL BE NOTIFIED ORF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK B. AISC CODE OF STANDARD PRACTICE,CURRENT EDITION. NOR MORE THAT 2"IN DIAMETER,AND SHALL AVOT BE LOCATED NEARER TO THE END OF LC UP (ALLY COLUMN UP ^ 3. IN THE CASE OF CONFLICT, THE MORE STRINGENT REQUIREMENT AS DETERMINED BY C. AISC DETAILING FOR STEEL CONSTRUCTION,CURRENT EDITION. THE SPAN THAN THREE TIMES THE MEMBER DEEPTH NOR WITHIN THE CENTER THIRD OF SHEATHING TO BE IO APA RATED STRUCTURAL SHEATHING,REFER 1 O 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ERECTION AIDES AND THE SPAN UNLESS REINFORCED TO MEET STRESS CALCULATIONS. TO PLAN AND SECTIONS FOR ADDITIONAL INFORMATION O u THE ENGINEER SHALL.CONTROL SUPPORT DOWN ID SHEATHING TO BEA77ACHED TO THE WALL STUDS WITH 8d NAILS `f' � 4. THESE STRUCTURAL©RAWINGS SHALL BE USED IN CONJUNCTION WITH THE PREPARATIONS TO PROPERLY SET THE STEEL FRAMING. THE CONTRACTOR SHALL BE 22. AT WOOD POSTS LANDING ON FLOOR DECK PROVIDE SOLID VERTICAL WOOD PER PLAN CALLOUTS ARCHITECTURAL,MECHANICAL ELECTRICAL,CIVIL,LANDSCAPE AND APPROVED SHOP RESPONSIBLE FOR COMPLIANCE WITH ALL CURRENT OSHA,STATE AND LOCAL SAFETY BLOCKING WITHIN DECK SANDWICH TO LINK UPPPER POST WITH LOWER SUPPORT. 3 2x4 (3)2x4 POST • HOLDOWNS TO BE HDU BY SIMPSON.SEE PLAN FOR MODEL DRAWINGS. REQUIREMENTS. BLOCKING TO MATCH UPPER POST S . 3 2x6 (3)2x6 POST NUMBER AND THREADED ROD SIZE. U 5. REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS,ELEVATIONS,EXACT 3. STRUCTURAL STEEL SHALL BEN WITH THE FOLLOWING MATERIAL PROPERTIES: 23. SET LVL BEAMS THAT FRAME FLUSH WITH DIMENSIONAL LUMBER JOISTS 1/4"BELOW J2-24 (2)2x4 JACK STUD+(1)KING STUD oofLOCATIONS OF FLOOR AND ROOF OPENINGS,POSTS,ETC.NOT SHOWN IN STRUCTURAL A. WIDE FLANGE SECTIONS: ASTMA992 THE TOP OF JOISTS TO ALLOW FOR JOIST SHRINKAGE.WHERE BEARING WALLS OR P,44 4x4 FIR POST 2. ALL PLYWOOD SEAMS RNA SHEARWALL SHALL BE BLOCKED WITH LL 4 DRAWINGS. B. ALL OTHER SHAPES,PLATES AND FABRICATIONS: ASTM A36 POSTS LAND ON THESE BEAMS,INFILL GAP WITTH 1/4"PLYWOOD FOR SOLID BEARING. P66 6x6 FIR POST DIMENSIONAL LUMBER OF THE SAME SIZE AS THE WALL STUDS. 6. NO DEVIATION FROM 1WHAT IS SHOWN ON THESE STRUCTURAL DRAWINGS IS C. HOLLOW STRUCTURAL SECTIONS(HSS): ASTM A500,GR.B PT 4x4 4x4 ACQ PRESSURE TREATED POST PERMITTED WITHOUT'PRIOR WRITTEN APPROVAL OF SAL ALL UNAUTHORIZED D. STRUCTURAL STEEL PIPES: ASTMA53,GR.B PT 6x6 6x6 ACC)PRESSURE TREATED POST 3. REFER TO PLANS AND SECTIONS FOR STUD SIZES,STUDS SHALL BE cN O DEVIATIONS FROM THIESE DRAWINGS MUST BE REMOVED AND REPLACED AT THE E. HIGH STRENGTH FASTENERS: ASTM A325 OR F1852 HSS 3% V c3XxX HOLLOW STRUCTURAL SECTION SPACED AT 161NCHES ON CENTER UNLESS NOTED OTHERWISE ON d CONTRACTOR'S IXPEENSE. F. MACHINE BOLTS(WOOD TO STEEL CONNECTIONS): ASTM A307 DESIGN CRITERIA 7, THE CONTRACTOR IS,RESPONSIBLE FOR THE DESIGN AND SAFE EXECUTION OF ALL G. ANCHOR BOLTS: ASTM F1554,GR 36(U.N.O.) LC 3/ 3/ 0 CONCRETE FILLED(ALLY COLUMN PLAN � ,� LC 4 4"t2)CONCRETE FILLED(ALLY COLUMN TEMPORARY SHORING,BRACING,OR OTHER PROTECTION DURING CONSTRUCTION. 4. AD CUTTING OF OR OPENINGS THROUGH STEEL WILL BE PERMITTED WITHOUT THE 1. DESIGN LOADS HAVE BEEN DETERMINED IN ACCORDANCE WITH THE NEW YORK STATE HDU# SIMPSON HDU#-SDS2.5 HOEDOWN(SEE SCHEDULE) 4. CARE SHOULD BE TAKEN TO ADJUST NAIL GUN PRESSURE SO AS TO � � THE STRUCTURAL DRIAWINGS INDICATE THE FINISHED CONDITION ONLY,WITHOUT VRITTEN APPROVAL OF THE ENGINEER. BUILDING CODE,2020 EDITION AND ASCE 7-16"MINIMUM DESIGN LOADS FOR BUILDINGS PSL 3%x3% VxV PARALLEL STRAND LUMBER POST NOT OVER DRIVE NAILS INTO PLYWOOD.NAIL HEADS SHOULD BE FLUSH O ASSUMING KNOWLED(GE NOR RESPONSIBILITY FOR HOW THE CONTRACTOR WILL 5. VLDED SHOP CONNECTIONS SHALL CONFORM TO THE STRUCTURAL WELDING CODE AND OTHER STRUCTURES." PSL 3%x5Y4 3%c5%4 PARALLEL STRAND LUMBER POST WllHPLYWOOD FACE.OVER DRIVING NAILS GREATLYREDUCES THE ACHIEVE THIS RESULiT. (iWS D1.1)USING E70VELECTRODES.HIGH-STRENGTH SHOP CONNECTIONS SHALL EFFECTIVENESS OF THE SHEARWALL 8. UNLESS NOTED OTHERWISE,DETAILS,SECTIONS AND NOTES SHALL BE CONSIDERED CONFORM TO ASTM A325. 2 GRAVITYLOADS: PSL 5%x5 5%4x7 PARALLEL STRAND LUMBER POST PSL 5%.x5'/. 5X,x5'/.PARALLEL STRAND LUMBER POST � TYPICAL FOR ALL OTHER SIMILAR CONDITIONS. 6. FELD CONNECTIONS SHALL BE HIGH-STRENGTH BOLTED CONNECTIONS CONFORMING A. DEAD LOADS: 9, SAI SHALL HAVE NO WABILITY FOR WATERPROOFING OR MOISTURE TRANSMISSION T)ASTM A325;3/4"MINIMUM BOLT DIAMETER. a. ROOFS. 18 PSF PSL xl lx7 P PSL 7x7 A7 PARALLEL STRAND LUMBER POST PARALLEL STRAND LUMBER POST CIA ISSUES, WHETHER RELATED TO CONCRETE SLABS,FOOTINGS,FOUNDATIONS,OR 7. PZOVIDE STIFFENER PLATES ATALL BEAM-OVER-COLUMN AND BEAM-UNDER-COLUMN b. FLOORS: 15 PSF c OTHERWISE. LOCATIONS,UNLESS NOTED OTHERWISE. c. INTERIOR WALLS: 10 PSF c\t 10. STRUCTURAL FRAMING LOCATIONS ARE DICTATED BY WALLS AND OTHER CONDITIONS 8. SEEL SHALL BE SHORPAINTED WITH A MODIFIED ALKYD PRIMER UNLESS OTHERWISE B. LIVE LOADS(REDUCED WHERE PERMISSIBLE PER ASCE7 SECTION 4.7): THAT ARE DIMENSIOAVED ON THE ARCHITECTURAL DRAWINGS.CONTRACTOR TO NOTED.COORDINATE WITH ARCHITECTURAL PLANS FOR MEMBERS TO RECEIVE SPRAY a. FLOORS. 40 PSF POSITION STRUCTURAL FRAMING ELEMENTS USING STRUCTURAL DRAWINGS IN AIPLIED FIREPROOFING. C. SNOW LOADS(AS STIPULATED IN THE NEW YORK STATE CODE AMENDMENTS): DENOTES CONJUNCTION WITH ARCHITECTURAL PLANS AND SECTIONS. 9. AL STRUCTURAL STEEL EXPOSED TO THE WEATHER SHALL BE GALVANIZED. a. GROUND SNOW LOAD,Pg.- 30 PSF POST UP 10. PIOVIDE 1/4"THICK LEVELING PLATES AND 3/4"OF NON-SHRINK GROUT UNDER ALL b. FLAT ROOF SNOW LOAD,IPf. 21 PSF x COLUMN BASE PLATES SUPPORTED ON CONCRETE.LEVELING PLATES SHALL BE SET QJ SHEARWALL SYMBOL ASSOCIATES FOUNDATIONS AID GROUTED SOLID BEFORE ERECTION OF THE COLUMN. 3. LATERAL LOADS: �O EDGE NAIL SPACING 1. ALLOWABLE SOIL PRESSURE AND LATERAL EARTH PRESSURE ARE ASSUMED AND 11. SRUCTURAL STEEL SHOP DRAWINGS SHALL BE PREPARED AND SUBMITTED FOR A. WIND LOADS: APROVAL. THESE DRAWINGS SHALL SHOW COMPLETE AND ACCURATE MEMBER POST STRUCTURAL C U A LENGINEERS THEREFORE MUST BE VERIFIED BYA QUALIFIED GEOTECHNICAL ENGINEER OR a. BASIC WIND SPEED, Vul1: 137 MPH 860 Walnut Street APPROVED BY THE B6ULLDING OFFICIAL IF SOILS ARE FOUND TO DIFFER THAN THOSE LAYOUT,SIZES,GRADE,DIMENSIONS,CONNECTIONS,OPENINGS,ACCESSORIES,AND b. OCCUPANCY CATEGORY.' ll GRAPHICAL Qp� ASSUMED,NOTIFY THILDING STRUCTURAL OFFICIAL OILSARFOR POSSIBLE FOUNDATION AL OTHERINFORMATIONNECESSARYFORCOMPLETEANDACCURATEFABR!CATION c. WINDIXPOSURE. D SYMBOL JQ � k STUD, ACING N Newton Centre,tel 02459 AN ASSEMBLY OF THE MEMBERS.PROVIDE TEMPLATES OR LOCATIONS DRAWINGS DENOTES k FOR SPACING 617.244.17 2 fa SUPPORTING 617.244.1732 fax REDESIGN. FC?INSTALLATION OF ANCHOR BOLTS. 2. EXCAVATE TO LINES SAND GRADES REQUIRED TO PROPERLYINSTALL THE POST SHEAR PANEL LENGTH www.siegelassociates.com FOUNDATIONS ON IMORGANIC,UNDISTURBED SOIL OR ON CONTROLLED STRUCTURAL BACKFILL AS REQUIMED.ALL EXCAVATIONS SHALL BE DRY BEFORE PLACING ANY ROUGI CARPENTRY PLYWOOD SHEATHING CONCRETE. 3. EXTERIOR FOOTINGS SHALL BE PLACED ON APPROVED SOIL AT A MINIMUM DEPTH OF 4 1 ALl STRUCTURAL ROUGH CARPENTRY SHALL CONFORM WITH THE"NATIONAL DESIGN FEET,OR AS MODIFIED BY THE STRUCTURAL ENGINEER,BELOW THE LOWEST SPECIFICATION FOR WOOD CONSTRUCTION,"ANSI/AWS NDS-2015. ADJACENT GROUND(EXPOSED TO FREEZING.ANY ADJUSTMENT OF FOOTING 2 UN ESS NOTED OTHERWISE,STRUCTURAL WOOD FRAMING SHALL HAVE THE ELEVATIONS DUE TO)FIELD CONDITIONS MUST HAVE THE APPROVAL OF THE FOLLOWING MINIMUM PROPERTIES: COMMON ABBREVIATIONS SYMBOLS LEGEND SHEARWALL SYMBOL ON BOTH r Tl ARCHITECT AND ENGINEER. A. FOR 24"(NOMINAL)THICKNESS KILN DRIED MEMBERS: SPRUCE-PINE-FIR(SPF) SIDES OF SHEAR WALL INDICATES 4. ASSUMED SOIL PROPERTIES: NO.1/NO.2 OR BETTER WITH THE FOLLOWING PROPERTIES: 1. SHEARWALL = a DOUBLE-SIDED SHEARWALL. A. MINIMUM SOI1L BEARING CAPACITY: 3000 PSF a. ALLOWABLE BENDING STRESS,Fb=875 PSI A.B. ANCHOR BOLT INSTALL PLYWOOD SHEATHING ON r B. LATERAL EARTH PRESSURE: 70 PCF(RESTRAINED) b. ALLOWABLE SHEAR STRESS,Fv=135 PSI ARCH. ARCHITECT 2. INTERIOR BEARING WALL = BOTH FACES OF WALL 45 PCF(UNRESTRAINED) c. COMPRESSION PARALLEL TO GRAIN=1,150 PSI BM. BEAM 5. FOOTINGS SHALL BE.CENTERED BELOW COLUMNS AND WALLS ABOVE,UNLESS NOTED d. COMPRESSION PERPENDICULAR TO GRAIN=425 PSI BIG. BEARING 3. BEARING WALL ABOVE OTHERWISE. e. MODULUS OF ELASTICITY,E=1,400,000 PSI BTWN. BETWEEM - 6. BACKFILL BELOW FOOOTINGS AND SLABS SHALL BE MADE WITHAPPROVED GRANULAR B. FOR 2-4" NOMINAL THICKNESS PRESSURE TREATED(PT)MEMBERS: CLG. CEILING 4. STEEL MOMENT RESISTING CONNECTION = V J (NOMINAL) COL COLUMN ® k x MATERIALS PLACED ION 6 LAYERS.LAYERS SHAG BE COMPACTED TO 95/o DENSITYAT SOUTHERN PINE N0.2 OR BETTER WITH THE FOLLOWING PROPERTIES: 5� 5� OPTIMUM MOISTURE:CONTENT,AS DEFINED BYASTM D1557,METHOD D. a. ALLOWABLE BENDING STRESS,Fb=750 PSI CONC. CONCRETE 7. BACKFILLING AGAINST WALLS OR PIERS MAY ONLY BE DONE AFTER WALLS OR PIERS b. ALLOWABLE SHEAR STRESS,Fv=175 PSI CONT. CONTINUOUS ARE BRACED TO PREVENT MOVEMENT.FOR WOOD FRAMED RESIDENTIAL c. COMPRESSION PARALLEL TO GRAIN=1,250 PSI CU COLUMN(UP CONSTRUCTION,NO,BACKFIWNG OF WALLS MAY TAKE PLACE UNTIL THE FIRST FLOOR d. COMPRESSION PERPENDICULAR TO GRAIN=565 PSI (E) EXISTING DECK HAS BEEN FRAMED AND SHEATHED,UNLESS WRITTEN APPROVAL IS GIVEN BY e. MODULUS OF ELASTICITY,E=1,400,000 PSI E.W. EACH WA'Y (J� THE ARCHITECT OR(ENGINEER. C. FOR 5"(NOMINAL)THICKNESS AND LARGER KILN DRIED AND PRESSURE FDN. FOUNDATION H 8, HOLDOWNS AND POST ANCHORS ARE TO BE INSTALLED IN ACCORDANCE WITH ANCHOR TREATED(PT7 MEMBERS:SOUTHERN PINE NO.I OR BETTER WITH THE FTG. FOOTING HOLD 0 WN UNIT SCHEDULE MANUFACTURER INSTALLATION SPECIFICATION AND ICGESR REPORT REQUIREMENTS. FOLLOWING PROPERTIES: HDR. HEADER ANCHORAGE OF THESE COMPONENTS INTO THE FOUNDATION SHALL BE CAST INTO THE a. ALLOWABLE BENDING STRESS,Fb=1,350 PSI HORIZ. HORIZONTAL u FOUNDATION, UNLESS NOTED OTHERWISE DIMENSIONS ARE NOT FURNISHED TO b. ALLOWABLE SHEAR STRESS,Fv=165 PSI G.C. GENERAL,CONTRACTOR SAI NOTATION SIMPSON NAME ANCHOR BOLT 0 A.B.CONCRETE EMBED. DESIGN FORCE(SERVICE) LOCATE EMBEDDED ANCHORS.IT IS THE RESPONSIBILITY OF THE CONTRACTOR,THE c. COMPRESSION PARALLEL TO GRAIN=825 PSI LC LALLY COLUMN FRAMING SUBCONTRACTOR AND THE FOUNDATION SUBCONTRACTOR TO LOCATE d. COMPRESSION PERPENDICULAR TO GRAIN=375 PSI LVL LAMINATED VENEER LUMBER DTTIZ DTT1Z-SDS2.5 e 6""** 850 LBF THESE ANCHORS IN'THE EXACT LOCATION MAX MAXIMUM( e. MODULUS OFELASTICITY,E=1,500,000 PSI DTT2Z DTT7Z-SDS2.5 Y. 10"** 1835 LBF 9. NO FOUNDATIONS SIHALL BE PLACED IN WATER OR ON FROZEN GROUND. 3. ENGINEERED LUMBER PRODUCTS SHALL BE TRUSJOIST BYWEYERHAEUSER AS A MFR. MANUFACTURER P.,i 10. CONCRETE PLACEMENT FOR FOUNDATIONS AND SLABS ON GRADE SHALL BE MIMijUM STANDARD OF QUALITY.SUBSTITUTIONS ARE NOT ALLOWED UNLESS MIN. MINIMUM COMPLETED IN A SIMGLE CONTINUOUS OPERATION,UNLESS NOTED OTHERWISE. SPECIFICALLYAPPROVED BY THE ENGINEER.ENGINEERED LUMBER FRAMING SHALL M.O. MASONRY OPENING HDU2-SDS2.5 %' 18"* 3285 LBF r , NTH 1 if. PROVIDE FOUNDATION DRAINAGE, WATERPROOFING/DAMP-PROOFING,AND N.T.S. NOT TO SCALE HDU4 HDU4-SDS2.5 %" 18"* 3285 LBF W w HAVE FOLLOWING MINIMUM PROPERTIES: FOUNDATION WALL IINSULATION AS INDICATED ON THE ARCHITECTURAL DRAWINGS. A. LAMINATED VENEER LUMBER(LVL): O.C. ON CENTER HDU5 HDU5-SDS2.5 %" 18"* 4340 LBF 12 PROVIDE METAL OR,PVC SLEEVES IN THE FOUNDATION WALLS FOR SEWER,GAS, a. ALLOWABLE BENDING STRESS,Fb=2,600 PSI PT PRESSURE TRETED P--� ELECTRIC,AND WATER LINES,AS REQUIRED. b. ALLOWABLE SHEAR STRESS,Fv=285 PSI PU POST UP HDU8 HDU8-SDS2,5 %" 18"* 6580 LBF ^ c. COMPRESSION PARALLEL TO GRAIN=Z510 PSI REQ, REQUIREID v J d. COMPRESSION PERPENDICULAR TO GRAIN=750 PSI SIM. SIMILAR HDU11 HDU11-SDS2.5 1" 24"* 8039 LBF e. MODULUS OF ELASTICITY,E=2,000,000 PSI SPEC. SPECIFICATION HDU14 HDU14-SDS2.5 1" 24"* 14445 LBF 7YP. TYPICAL *MINIMUM ANCHOR BOLT CONCRETE EMBEDMENT VALUES FOR ALL HD)U A B. PARALLEL STRAND LUMBER COLUMNS U.N.O. UNLESS AVOTED OTHERWISE PRODUCTS BASED ON CAST-IN-PLACE CONSTRUCTION UNLESS CONCRETE a. ALLOWABLE BENDING STRESS,Fb=2,400 PSI 1. ALL CONCRETE WORK SHALL BE PERFORMED IN CONFORMANCE WITH THE LATEST b. ALLOWABLE SHEAR STRESS,Fv=190 PSI VERT. VERTICAL EDITION OF AC1-318, "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE°AND c. COMPRESSION PARALLEL TO GRAIN=2,500 PSI V.O.P. VERIFY OR PROVIDE OTHERWISE NOTED BY ENGINEER. A ACI-301, 'SPECIFICATIONS FOR STRUCTURAL CONCRETE.' d. COMPRESSION PERPENDICULAR TO GRAIN=545 PSI V.I.F. VERIFY IA1l FIELD **MINIMUM ANCHOR BOLT CONCRETE EMBEDMENT VALUE USING U 2. UNLESS NOTED OTHERWISE,CONCRETE SHALL ACHIEVE A MINIMUM 28-DAY STRENGTH e. MODULUS OF ELASTICITY,E=1,800,000 PSI W/ WITH MECHANICAL ANCHOR. W AS FOLLOWS: 4. ENGINEERED LUMBER JOISTS SHALL BE TJI"BY TRUS JOIST BY WEYERHAEUSER.JOIST x A. FOOTINGS, WAALLS,PILASTERS,COLUMNS: 3,000 PSI(NORMAL WEIGHT) SERIESAND SIZE SHALL BEAS INDICATED ON THE CONSTRUCTION DRAWINGS.INSTALL V B. SLABS-ON-GRADE,STRUCTURAL SLABS,BEAMS: 4,000 PS!(NORMAL WEIGHT) JOISTS IN CONFORMANCE WITH MANUFACTURER'S REQUIREMENTS. 5. UNLESS SUPPORTED BY HANGERS,ALL JOISTS SHALL HAVEA MINIMUM END BEARING C. TOPPING SLABS AND PADS: 3,000 PSI(NORMAL WEIGHT) 3. SLUMP AT THE POIN17 OF DISCHARGE FROM THE READY-MIX TRUCK SHALL BE 3-5". OF 2"CND A MINIMUM INTERMEDIATE BEARING OF 3-1/2". CONTRACTOR MAY SUBMIT FOR REVIEW HIGHER SLUMP MIX DESIGNS INCORPORATING 6. ALL STRUCTURAL SHEATHING SHALL CONFORM TO PS-1,PS-2AND BE APA RATED WITH OVERDRIVEN NAILS DIAGRAM a THE MINIMUM PROPERTIES: THE USE OF PLASTICCIZER ADMIXTURES. 4. ALL CONCRETE EXPOOSED TO WEATHER SHALL BE AIR ENTRAINED FOR SEVERE A. SUBFLOOR SHEATHING SHALL BE MINIMUM 23/32"THICK TONGUE AND GROOVE, EXPOSURE 1, GD GRADE PLYWOOD OR STRUCTURAL 1 GRADE ADVANTECH EXPOSURE 5. ALL CONCRETE SHALL BE PLACED WITHOUT HORIZONTAL CONSTRUCTION JOINTS EXCEPT OSB SHEATHING.PANELS SHALL HAVEA MINIMUM 24"SPAN RATING.FLOOR w ~ SHEATHING SHALL BE GLUED TO FLOOR JOISTS WITH AN APPROVED ADHESIVE 001 WHERE SPECIFICALLLY SHOWN. VERTICAL AND HORIZONTAL CONSTRUCTION JOINTS IN PRIOR TO NAILING. ARCHITECTURAL CONCRETE SHALL ONLY BE MADEAS SHOWN ON THE CONSTRUCTION B. ROOF SHEATHING SHALL BE MINIMUM 19/32"THICK EXPOSURE 1,C-0 GRADE CL DRAWINGS,NO DEVIAATION IS ALLOWED. PLYWOOD OR STRUCTURAL 1 GRADE HUBER ZIP SYSTEM ROOF SHEATHING 6. CONCRETE PLACEMIENT IN COLD WEATHER CONDITIONS SHALL BE IN COMPLIANCE WITH PANELS.PANELS SHALL HAVEA MINIMUM 40/20 SPAN RATING.FOR SPANS OF ACI-306"GUIDE TO COLD WEATHER CONCRETING.' 24"AND GREATER,PROVIDE TONGUE AND GROOVE EDGES OR METAL H-CLIPS JOl ST/BEAM PLAN KEY.• 7. CONCRETE PLACEMENT IN HOT OR WINDY CONDITIONS SHALL BE IN COMPLIANCE WITH N CENTERED BETWEEN RAFTERS. DENOTES DROPPED BEAM OK OK NG � ACI-305"SPECIFICATION FOR HOT WEATHER CONCRETING." C. 'WALL SHEATHING SHALL BE MINIMUM 15/32"THICK EXPOSURE 1,GD GRADE 8. SLABS ON GRADE SHALL BE PLACED AT THE ELEVATIONS AND SLOPES INDICATED IN THE WITH JOISTS FRAMING � PLYWOOD OR 7/16"THICK STRUCTURAL 1 GRADE HUBER ZIP SYSTEM OVER THE TOP OF BEAM ARCHITECTURAL AND STRUCTURAL DRAWINGS.SURFACE FLATNESS SHALL BE 1/8"IN 10' SHEATHING PANELS.PANELS SHALL HAVEA MINIMUM 24/16 SPAN RATING. A \ UNLESS NOTED OTHERWISE 9. NON-SHRINK GROUT SHALL BE MASTERFLOW 555 BY BASF MASTER BUILDERS OR PRE- 7. UNLESS INDICATED OTHERWISE,ALL ENGINEERED LUMBER JOISTS SHALL BE DENOTES THAT JOISTS APPROVED EQUAL.GROUT MAYBE PLACED FROM 25 SECOND FLOW TO A STIFF INSTALLED INA SIMPLE SPAN CONFIGURATION. MUST BE SPLICED PACKING CONSISTENCY.FILL OR PACKACED SPACE UNDER PLATES OR SHAPES. 8. ALL WOOD HAVING DIRECT CONTACT WITH CONCRETE OR MASONRY,AND WHEREVER OVER BEARING WALL FOLLOW MANUFACTURERS RECOMMENDATIONS FOR PREPARATION,INSTALLATION AND IVOOD IS WITHIN 8"OF FINISHED GRADE OR PART OF OPEN DECK CONSTRUCTION, OR BEAM. SHALL BE PRESSURE TREATED. CURING. 9. NOMPT BEAM ENDS SET IN CONCRETE BEAM POCKETS SHALL BE WRAPPED IN SELF- WHERING RUBBER MEMBRANE 10. 4NGERS AND CONNECTORS SHALL BE BY SIMPSON STRONG-TIE CORP.THE DENOTES DROPPED BEAM W REINFORCEMENT 3ONTRACTOR SHALL STRICTLYADHERE TO MANUFACTURER'S FASTENING REQUIREMENTS.ALL CONNECTORS SHALL BE INSTALLED WITH THE MAXIMUM WITH JOISTS FRAMING OVER THE TOP OF BEAM 1., STEEL REINFORCEMENT DETAILING,FABRICATION AND INSTALLATION SHALL BE IN FASTENER QUANTITY,UNLESS NOTED OTHERWISE.All CONNECTORS EXPOSED TO CONFORMANCE WITH THE LATEST EDITION OF ACI-318, "BUILDING CODE WEATHER SHALL BE ZMAX GALVANIZED COATED. REQUIREMENTS FOR REINFORCED CONCRETE"AND ACI-315,DETAILS AND DETAILING 11. UNLESS NOTED OTHERWISE,MULTIPLE 2x POSTS,SUCH AS 2-2x6,3-2x6,ETC.,SHALL BE DENOTES I- - -. OF CONCRETE REINFFORCEMENT." CONFIGURED WITH ONE 2x AS A KING STUD AND THE BALANCE AS JACK STUDS. MUST O CONTINUO NUOUS O 2. REINFORCING STEEL BARS SHALL CONFORM TO ASTM A615,GRADE 60 DEFORMED. 12. SOLID LUMBER POSTS WITHIN WALLS SHALL BE INSTALLED IN JACK CONFIGURATION WITH NO SPLICES OVER z BEARING WALL OR BEAM. 3. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A 1064 WITH A MINIMUM TENSILE WITH ONE ADJACENT 2x KING STUD ATTACHED TO POST. a W STRENGTH OF 70 KSL ALL WELDED WIRE FABRIC SHALL BE SUPPLIED IN FLAT SHEETS. 13. UNLESS NOTED OTHERWISE,PROVIDE AT LEAST TWO JACK STUDS BENEATH ENDS OF 4. LAP ALL CONTINUOUS BARS A MINIMUM OF 42 BAR DIAMETERS. 2X12 AND ENGINEERED LUMBER HEADERS AND BEAMS. ry 5. REINFORCING BARS;SHALL BE CONTINUOUS THROUGH CONSTRUCTION JOINTS, 14. FOR WOOD JOIST SPANS UP TO 14 FEET,PROVIDE A SINGLE ROW OF FULL DEPTH LJJ r`7 UNLESS INDICATED 10 THERMSE BLOCKING BETWEEN JOISTS AT MID SPAN.FOR SPANS EXCEEDING 14 FEET,PROVIDE W Z Z 6. MINIMUM CLEAR COINCRETE COVER FOR REINFORCING(UNLESS NOTED OTHERWISE): TWO ROWS OF FULL DEPTH BLOCKING BETWEEN JOISTS AT THIRD POINTS OF THE DENOTES FLUSH BEAM WITH JOISTS HANGING INTO FACE OF _ H � � A. FOOTINGS AND CONCRETE CAST AGAINST EARTH: 3" SPAN "" B. FOUNDATIOI N WALLS AND CONCRETE IN CONTACT WITH EARTH. 2" 15. PROVIDE SOLID BLOCKING BETWEEN JOISTS AT ALL JOIST BEARING LOCATIONS. BEAM W/SIMPSON HANGERS C. INTERIOR EXPOSED WALL FACES: 1" . PROVIDE DOUBLE JOIST UNDER PARALLEL PARTITION WALLS OR SOLID BLOCKING @ 32" *� �� n�p(� 16 DENOTES THAT JOISTS l L�%Uk D. FORMED CONCRETE EXPOSED TO WEATHER 1.5" A� 4 O.C.BETWEEN THE CLOSEST TWO JOISTS. �� E SLABS-ON-GRADE: 1.5" 17. GABLE-END WALL STUDS IN CATHEDRAL,PARTIAL CATHEDRAL,OR HIGH CEILING J L LL J L J L J L J L MUST BE SPICED,AND G / i` F. SLABS NOT EXPOSED T O EARTH OR WEATHER: 1" SPACES SHALL SPAN UNINTERRUPTED FROM THE FLOOR PLATE TO THE UNDERSIDE OF r r r r HANG ON FACE OF BEAM 4s �r� 7. CONTRACTOR SHALL PROVIDE AND COORDINATE ALL EMBEDDED ITEMS INCLUDING `� $ \'F Pt THE RAFTERS.THEY NOT BE INTERRUPTED BYANYHORIZONTAL PLATES �'� CONDUIT,SLEEVES,AND THROUGH PENETRATIONS WITH OTHERS.STEEL REINFORCING OR BEAMS, UNLESS NOTED OTHERWISE ON THE DRAWINGS. v �� T OR DISPLACED WITHOUT EXPRESSED WRITTENAPPROVAL OF THE - M WHETHER MADE OF SAWN OR ENGINEERED SHALL NOT BE CU 1 18. MEMBERS WITHIN BUILT-UP BEAMS, STRUCTURAL ENGIMEER. LUMBER,SHALL ONLY BE SPLICED OVER SUPPORTS. 8. TACK WELDING OF REINFORCING BARS IS NOT PERMITTED. O 19. PROVIDE SIMPSON H2.5A HURRICANE TIES BETWEEN EACH RAFTER BOTTOM AND ITS ,,f J �t�1_ ,0'�,���; s000 9. SUBMIT COMPLETE;SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION. BEARING POINT. r_ 00 10"0 CONCRETE PIER \ / O 6-8 7/16" 6-8 7/16" 6-8 7/16" 6-8 7116" T-10 3116" 7-10 3116" 7-10 3/16" 3-11" 8'-414" j ON 2470 BELLED FOOTING, TYP.U.N.O. U O }- - - -}-- - - --( - - ( - - -7� 11 - - -( - - - �-- - - - -� �- f- )- - - - - 0 0 0 u I I QJ QJ QJ I QJ QJ QJ I QJ U I I I ALIGN WITH PORCH FRAMING ABOVE I I a/ pp / � PROVIDE FROST PROTECTION AT ABOVE N O GRADE WALL PER"SUPERIOR WALLS" I I I 17-111/2" 2-6" a Ln RECOMMENDATIONS.SEE 4/S3.1 Ln OPENING IN WALL PANEL FOR 3 /n'! _ 7 53.2 No � o WINDOW,SEE ARCH.PLANS FOR r_ BEAM LOAD:1.10 K OPENING IN WALL PANEL FOR _ - -- ------ SIZE AND LOCATION I BASEMENT DOOR,SEE ARCH. i f ) PLANS FOR SIZEAND LOCATION ( ) I ---- -- ----- ------- '� 2 Q Q Q 31.0 ---- -------� I 0 0 N \ G•' S3.2 �, 6 S3.2 6 0 � G I O Q• �,. ��Gs YS31 �s rs ��G ��G / \ p WALL LOAD:--/ --L ------- -- I � 1.92KLF I Lr--IL r -- ------- ------ ----------- Ir I I WALL LOAD: ��\ , i r�---------- ---------�---L- --ram--- -t � ---r' �O�` • 1.30 KLF 0 Q I I WALL LOAD: WALL LOAD: \ G I Q e BEAM iLOAD:3.87K QJ h`L �1 QJ ��� I I 2 r' ASSOCIATES I 0.75KLF 1.92KLF 5� \' !'� \' I I S3.1 STRUCTURAL ENGINEERS Q�0 I I T--81/2" 3'-6" 11-1118" 11-4 3/4" 2'-71/4" 6'-0" 26'--2 718" I ! I 860 Walnut Street 2 OPENING IN WALL PANEL FOR I Newton Centre,MA 02459 BEAM LOAD:2.20 K I S3.1 I i I " " , " WINDOW,SEEARCH.PLANS FOR Sim 617.244.1612 tel 3-0 x3-0 x1-0 SPREAD I I 1 � 'OG I I " FOOTING W/34#5BARS SIZE AND LOCATION Cn 617.244.1732 fax I I 5-51/2 EACH WAY BTM I �i I S3.2 www.siegelassociates.com --- I J i ! ! r----- � Q ! l ! l l I I BEAM LOAD:2.87K I i G,o G,o I I �G G,o G,o G,o G,o G,o I II L 4-91/4 1 o ? II I I I 4 I I I I I I I I I I I I N 1 1 I I I ^ I L J L__J L__J I I L__ I L__ I I I W I I BEAM LOAD:2.42 K r I I I I L____J � CMU CHIMNEY,DIMENSIONS �..( I I I 1 1 PER ARCH PLAN W rz II . I I 1 I II = I 2'-0'x2'-0"x1'--0"SPREAD L- -- ----� 4"CONCRETE SLAB ON GRADE o 1 I I I I I FOOTING W/24I5 BARS W/6x6-W1.4xW1.4 WWF v EACH WAY BTM, TYP.U.N.O. " I 1 12 THICK FOOTING 12"THICK 1 1DIMENSIONS3'-0"x3'0"x1'0"SPREAD I WALL LOAD: CMU CHIMNEY, FOOTING W/34I5 BARS FOOTING I 0.75 KLF I 1 I PER ARCH PLAN EACH WAY BTM BEAM LOAD:2.21 K L______ BEAM LOAD:0.50 K `/ J I a I " 37-0 J� �Q JQ JQ JQ BEAM LOAD:0.81 K I g��GA i I WALL LOAD: WALL LOAD: - ,j,OGVQ �G �G �G �G ,o J 1 L 0.75 KLF 1.30 KLF __ I 1 i r----t r- -t r- �,'r� r- -- r --- r--- �---- ----t ----, I I ! . ., L-------------- ---- -------i LJ L - -------------------� i i H ------ ------------ JO\L ---� �- -J�\ ----� I r-� L----J L-- -1 --- I r==-�-----L� cv _ \Q S31 OJT GHQ QJ��G\Q �OJG� I I I I r ------ 10"DEEP CRUSHED STONE 1 1 I 1 1 F.l••l FOOTING BELOW 11 j , " BEAM LOAD:2.20 K BEAM LOAD:1.10 K BEAM LOAD:8.20 K 2-6x2-6 aoc1-0 SPREAD FOUNDATION WALL FOOTING'W/345 BARS I I HOLDOWN FROM POST ABOVE.SEE NOTED 2 I I EACH WAIY BTM I I 5'--10" 9-2" (SERVICE)DESIGN FORCES ON S0.01.PROVIDE S3.1 I I I ; Q I I ADDITIONAL CIP OR PRECAST CONCRETE MASS I I I o �GJQ �GJQ �G�Q i I BEAM LOAD:4.26 K TO RESIST UPLIFT AS REQUIRED, TYP. 101/4"WIDE SUPERIOR WALLS ac _ _ r \ ft X PRECAST FOUNDATION WALL 0 t- w � SEE 5/S3.1 11 1LU 0 4 wo LL % o w "_ l o Z L__J L__J ( I WALL LOAD: I I A A ISOLATED FOUNDATION DESIGN OPTION L--- 1.30 KLF I I I 4 G [� ISOLATED SPREAD FOOTINGS MAYBE REPLACED WITH'SUPERIOR WALL" BEAM LOAD:2.05 K I 1 ` I P a w I I V-2 PRECAST COLUMN PADS AS FOLLOWS: I I l o w " j I I I V WALL LOAD: ALL 2'-0"x2'-0"x1'-0"SPREAD FOOTINGS:2'-0"x2'-0"x41/2""SUPERIOR WALL" 0.40 KLF I I L -- - ----- - I 5-10" ��3 PRECAST COLUMN PAD W/8"DEEP CRUSHED STONE BELOW PAD BASE I I I AL � I 1 I \ -ALL 2'-6"x2'-6"x1'-0"SPREAD FOOTINGS:3'-0"x3-0"x6""SUPERIOR WALL" - ---- ----, PRECAST COLUMN PAD W/8"DEEP CRUSHED STONE BELOWPAD BASE 1 I 1 I I FOUNDATI SUPPORTIN SHEAR z I I '-_-_____- " " " " "" " I I I 3 1 1 W ALLA B©k TO BE DE$IG I ED FOR o W W I 1 I -ALL 3-0 x3-0 x1.0 SPREAD FOOTINGS:3-0 x3-0 x6 SUPERIOR WALL PRECAST COLUMN PAD W/8"DEEP CRUSHED STONE BELOW PAD BASE I ( S31 I I-MINIMUM 2600PLF(ASD)_S EAR LOAD w o ,°i L----------� I 1 I I A I I CL I I I G I I 101/4"MDE SUPERIOR W S 00 CO Q 1 1 1 -CHIMNEY MASS FOOTINGS:SUPERIOR WALL PRECAST FROST WALLS MAY BEAM LOAD:3.10 K BEAM LOAD:2.31 K w `'', c� .g G x PRECAIST FOUNDATION ALL o ti. BE USED TO SUPPORT CHIMNEY MASSES.DETAILS AND INSTALLATION TO I 1 1 P, s I 1 I ' 0 BE SPECIFIED BY SUPERIOR WALLS. I I I A I L, N I • L--- -----t I o 4 " Xco 0 Uj 6"TOP OF WALL 1 1 i --- - -- --------J---, ,`a I �0 t-+ STEM THICKNESS PER 1 I I �OG�� ------- -`� SUPERIOR WALLS DESIGN I QJ. J• I r --- ------ ------------- r - --� N I I �g J�\ ----� WALL LOAD: L-I 1--t �OJ V . i--- -I W N 101/4"WIDE SUPERIOR WALLS I I �O��Q 1.30 KLF \ 1 1 QJ ��' o_ Ui PRECAST FOUNDATION WALL I QJ O�"L�' I L gh0 A I I I TOP OF FOUNDATION WALL QJ` G I I HOLDOWN FROM POST ABOVE. I I I UNSUPPORTED AT STAIR OPENING. �iti I I SEE NOTED(SERVICE)DESIGN 2'-6"x2'-6"x1'-0"SPREAD "SUPERIOR WALLS"TO PROVIDE SILL L, r J FORCES ON S0.01.PROVIDE FOOTING W/34I5 BARS REINFORCEMENT AS REQUIRED I ADDITIONAL CIP OR PRECAST 6 1 I I CH WAY BTM JQ JQ I QJ CONCRETE MASS TO RESIST O UPLIFTAS REQUIRED, TYP. SEE 5/S3.1 WALL LOAD: I I I I I I CRUSHED STONE FOOTING --►I I I W 0.40 KLF 1 1 I I I I I PER"SUPERIOR WALLS" I ( z I I I I I I I RECOMMENDATIONS I I Q U I I I I I I WALL LOAD: ft z 1 1 1 I I I 1.30 KLF O j 4'CONCRETE SLAB ON GRADE W16x6-W1.4xW1.4 WWF I I I 6 I I (PITCHED FOR DRAINAGE-SEE v S3.1 cfl I ARCH DWGS) 1 2-67x2'-67x1'-0"SPREAD Q I I I a O I FOOTING I I I f ti p 1 7 HAUNCH CONCRETE SLAB i S31 I I 1 I I I HOLDOWN FROM POST ABOVE.SEE I I I I OVER LOWER FOUNDATION I I I I NOTED(SERVICE)DESIGN FORCES ;• y f A I I I I I WALL AT DOOR OPENINGS I I I �\ jr.= i,,,;.;.s :'; trFti4 L-- 7 W50 KL OAD: 6G L J �j.p� ON S0.01.PROVIDE ADDITIONAL CIP ��; I �\ ,o I p Q• .zti VQ ,�0 �Q J G OR PRECAST CONCRETE MASS TO o I I Q ' A� I J G J G O G J G I ate RESIST UPLIFT AS REQUIRED, TYR ,, (::)�f OUNDATION PLAN J L am � Q � -� -i L I �`s I SEE 8/S3.1 ',t> Scale: 1/4"= 1'D" I --- -=-- -- ______----=--------- -- -------_- - I - _ ' ` • r--� r-7 r------------------ ---------------I L J4,6" L- �3'0V- �"- � 20'-0" 2�'_ J 2-2x8 ^ L U J c / r Q 1 A J A A • I— `~ J J A 6 6 rp A Q G Q G Q G oxo co ,<<o� r N STAIR 0 Q Q� x L N W J L W E -IF -ir -ir -ir r -ir IF -IF -ir/ -ir -IF 'ir �r -ir -ir -ir -ir -r, -ir -ir -ir -ir -Ir -ir �r �r -ir r -ir -ir -ir -ir -i -ir -ir -ir -ir -ir -ir 'ir -I r- -ir j O U 2x6 HORIZONTAL BRACE TO B1 PT -2X12 13± ONG, ONT UO \\ B 23 P 3-2x 2, 13-1 LON ,CO (NU S 1 PT -2x1 23'_ ONG, ONT NUO 127 T 3- 21 12 LO ,CO iNU US UNDERSIDE OF JOISTS, // \ // \\ I v� 6X6 PT DIAGONAL T' O FASTEN TO EACH JOISTS W/ / \ /olb, / \ +6 A o ! KNEE BRACES, TYP. I (2)'/."DJ x 4"LONG FRAMING A / \ Q �„ / \ 6�� Q I AG ��, z 6 SEE 6/S3.2 ( , SCREWS, TYP. � cn PT 12 16"0. . // \\ PT 2x12 16° .C. Q� // PT 2 12 6"0. . I ° Z �r�4 v O @ o @ \ J PT2 12@ 16 0. o Q O I-j Z D CKJ ISTS / \\ DECK GIST Z // DECK J ISTS \\ - I DECK J ISTS 6X6 PT DiAGONAL KNEE BRACES, TYP. I SEE 6/S3.2Ln v /,/pO \�i o cq � C' G d \'Py Q cv DTT2Z HOLDOWN TO / �, \F `Z`j \� \� N Uj r., FLOOR JOIST 4 LOCATIONS Aj �* / 6' \ Q I 3 Q Q N COORDINATE OPENING 6�6, �p / \ cV Q� I 3.2 a O REQUIREMENTS WITH k / \ QJ 1 4' \ / \ DTT2Z HOLDOWN TO SUPERIOR WALLS, TYP. 1 cNv / ti \ a_ /i/ \ L JL JL T d-ED ER J J L J L 81 S3.2 a / CL \ o, . - — FLOOR JOIST,4 LOCATIONS \ \ N \b J 3 A G 1 G G G / J L P 2x12 L DGJL R J L O Q \ /� 3.2 Q Q Q O O Q p�J ` ` ` S3.1 S AiR,DO A/1 'y0 J L - - QJ� \ \ OV \ AV NG J L L [ / PT 2x 2 LE GER [ �\ , [1d1 + M L JL _ �� JL L JL_Jt �L­ JL JL J JL JL JL JL J JL JL i ` 110 S E DE AIL 3 S3.2 OR � — 6130�r y r �r -- -- - -= - — • LFDGERFASIENIN AT DTT ZHO OWPAT ASSOCIATES Q B M L CATI NS, P. Q 2x1 @ 16 O.C. FLO R J01 T,4 ONS STRUCTURAL ENGINEERS 860 Walnut Street 2 `i M �+ -• — COORDINATE OPENING Newton Centre,MA 02459 S3.1 R61 m o REQUIREMENTS WITH 617.244.1612 tel BOG m o SUPERIOR WALLS, TYP. 617.244.1732 fax 6 CON RE SLAB J fi CONCRETE SLAB J�105 J L 2X1 J L Q " www.siegelassociates.com ART W/# @ 12 O.C. HEARTHW/#4 @ 12"O.C. G Ini _ B RS E CH Y �' BARS EACH WAY 6QB 01 3 9%'L L,18' LON ,CO INU US B10 3-9' LVL, 0'±L NG, ONT! UOU B 09 3- '<"L 20' LON CON INUO S 8 1 3-9' "LVL, 0'±L NG, ONTi UOUJL JL JL JL JL JL JL JL JL JL JL JL JLJL JL JL JL JL JL JL JL JL JL JL JL JL JL L JL JL JL JL JL. JL JL L JL JL JL JL JL JL L JL JL JL JL JL JL JL JL JL JL JL J JL JL �r �r �r �r �r �r �r �r �r �r �r �r �r �r -ir �r �r �r �r -tr �r �r �r �r �r �r �r �r �r �r �r rA IGN C LUM WIT WAA OVE. ROV E 5" iN.B RINS3.2 `Pov MASONRYCHIMNEY I' 104 2-2X16 SON YC MN 5 Q S3. c J� 7 N Q Sr G m 1 2X1 16 O.C. B 14 2'2x10 r I � -- B 15 3- '/<"L L, 6' LON , CO IINU S J B11 3-9 ,"LVL 22'± ONG ONT NUO ------ -- L JL JL JL JL - JL JL JL JL -- L JL JL JL JL JL JL JL JL JL JL JL JL JL JL - �r Lj---i _1 r- -Ir 'y r ',r -1r 1r it -ir �r 7r IF Jil I QJJ�\ S3.1 J�O QJ� QJ ---- - - —." � .oG .oG -'e Q �p I lc PT 2x12 LEDGER I BOG 2Xf0 16"O.C. r 2 L CONCEALED HANGER TO 2x12 PT LEDGER, S3.i A L w U m J TYP.EACH END vi r � ?• w i L;' SEE DETAIL 4/S3.2 FOR B11 3-9 °LVL 16'± ONG, ONT iU0 B11 3-9' "LVL, 16'±L NG, ONTI UOU r N w LEDGER FASTENING AT J L J L J L J L J L J L J L L J L-J L N J BEAM LOCATIONS, TYP. r -i r -i r -I r r -rr r— J L 6�6 J T1 r V Q ,,1 �0 r QJ W P x L V � r PT 2X12 LEDGER-_L, m A A 2X @ 1 'O.C. F- w — — — cr_ Q Qa� J J W o TOP OF FOUNDATION WALL QJ`�\� A o UNSUPPORTED AT STAIR OPENING. "SUPERIOR WALLS"TO PROVIDE SILL REINFORCEMENT AS REQUIRED ,ZOO 6 JQ JQ QJ QJ I CD z I I < 1 U \ SLAB ON GRADE Elf (SEE FDN PLAN) 0 a . O � cv 01 cry --" .oG J 7 J J J 7 S3. �� ���`r0 S3.1 FIRST FLOOR FRAMING PLAN G QJ QJ QJ Q �� �'"i `����' f 2x EAVE RAFTER CUT TO CURVE(MIN.31/2"DEPTH)@ 16"O.C. (n 00 2x4 JOISTS @ 16"O.C., TYP. DOUBLE UP JOISTS BENEATH �- O DORMER HEADER POSTS ABOVE,TYP. V I I I I I +�4�._711 2x LED ER Hj _ I f ► I I I I W g - =g2 LE ER L W --- - -- -- -- w O ----B2 3 z = --- �8218 3�J " - - Z W -- ; � ; ; � -- f O u TT o a = J o �? ...L.. J L J L J L F� O �► V O I - J L J L J L O- _ — L+�j r -i r r — p L..1 O rid DECK BELOW a `��` w o per", J �? �' w w I! DECK BELOW W W V -•J J Q J L J L - J I +J — !� UQ- CC,-) it k ! o O r O r O , O 2- c� �, C14 � > to N N M --- N L L L --- O = _ = N N I o rn r o rn r o rn r o OVERFRAME ' k t P ' L n L - L t••. — N -- CV 1 r N r r N OD, •trO N L N L N L N', V�6 Y, CS16 COIL STRAP(36'MIN.) -- r r r `� , _. I 4' i 7 2x EAVE RAFTER CUT TO CURVE MIN.31/2"DEPTH 16"O.C. I --'' J L J L J L HEADER,REFER TO ( )@ - r r r 2 x . : -_ - 8= _- -- .i IEAVE RAFTERS BLOCK BETWEEN FLOOR JOISTS AT ROOF FRAMING PLAN V� =-- 2X4 JOISTS @ 16"O.C., T 1 r. 2- x10 L J L J L .t -' TYP RAFTER LOCATIONS,2 BAYS MIN FASTEN I - - SHEATHING TO BLOCKING WITH 8d NAILS I r -1 r - r o Y: 2X 2@ 6"0 �10- - AT4"O.C.,--- -- - P.AT GAMBREL FRAMING J L J L Al J L 6 Q cV I I I TY 1 r " r 1 r GER IGH-- -2x4 DGE 0 l I -- - 4 - ----- - --J L-- -- - )l &LO - ,tipe� ro_ I I / I I I I 1� I i _ IIIJ J L x12jRAFT-rRS DGE CHI L J L J L_ J L r 1 I + pJ i_ I - ' " _. 4 , " ? .o I I -B209-1146- LOW` =1 ----- I I -- - ' 6-3=18"LVL`-- i 2 5 z_LVLg s --_ 2114 9/z L L 8213 3-9/ LVL I I r..- 4 t ; , I I 1 1 I I I �--- I J L G J I I I I I I J L I I I I I e 2-2x6 STUD FASTENED TO J L L 22-0 1r \ r11rl I I I I ADJACENT POST W/ \I� I I I I I I I I 1 I I I I I FRAMING SCREWS Y I ( Q I IJ L I I I I ti0 �I� I ��O 1 QJ�fi�° I L "'� t? AG a J L ��O i. I �j�G L I I I I I J L ASSOC d J L L J L BLOCKING BELOW CS16 J L O I - --- J L "'G� J L L - -------- STRUCTURAL _ �I BLOCK BENEATH DORMER J 1 r , r , r II -- WALLS PARALLEL TO 860 Walnut Stre, CS16 COIL ST ( 6"MIN.) I I o FRAMING, TYP. \� r , r J L J L J L Newton Centre, x L J L L J L _ r r SHEAR WALL ABOVE BLOCK r N p ___ 617.244.1612 tel r Q a J V J L I ItJ L BETWEEN JOISTS LOW J L TI I @) 617.244.1732 fax J L L J L 6 1 r 1 r 1 r _'--rli a www.siegelassoci, r r \ 1 r r r = I V C> I C5 V J -- - - I 'J L — J L L >J L --J1 r 'I r p J1 r p = a MASONRY CHIMNEY 2-2x8 �o ao r �o r io r oo i p I00 CIO 00 .oG w L-- --'-- — --------- CV •i'J L c�0 P to J L .' J L •' ep r.. r N r -- - N - 3��J°�V� c� ( l r t r 6, z J L C7 L J REFER TO ROOF FRAMING PLAN °O co °b "' + CID "I "' 00 co \ N N N x O O k I O h O >C x U>j NJ L N W Cep cn 'L �� ; FIELD!DRILL HOLE F fi r ( ' r r B208 8 j J J L L J L PLUMBIING.MAX 3"D)A Q o J L J L J C W UO 0 it r -ir apm 1r 1r 1r w _ --- - - J 2-2x8 J L L - -- BEAM HEIGHT ; r =2-2x8 = 1 L ; L i� `v `T - v N 1rft � r r � � LJ L I L J L J L I J L J L (•L I I cf6, 1r I� r G � r � r I .O � r � r i v J J L L J L , r GJ r 1 r ! U L L B234 3-2x8 I J L I B235 3-2x8 G �" J L J L - I cv r , - �- -� i M' J L ��--__�z_- --_ J L L I A J L L �o A x r 1 r -c? r 'p ca r t r I I F I �'. I 1 I I u? I �i O _ `t?�� I � 0+ -I �.b f I I ��- �+ 0+ �+ � ��. �� I �y y MASONRY CHIMNEY I ly I I I J L I I I i 6' I iL Izi ► �6 I J L �'' 0' �' 3 L J L I I fd' 1 61 I J 1 N8 I 13-2 8 h r 13-2x8 I I I � r I + " 1 �I� r , r 8225 3-16"LVL � �pG 6123 319/ L�/L 8 24 3- x10 L I I - -3-2X8 I. I 2x12 LEDGE - -- - i 1� i I I I p ,a - - R; y ;:..:: .• 13 . 2x121 DG HI GE H1 - - ti� i 2x4 GE ILOW I I I I l� _ �0 1 _.o 2x4 Lou LO -- �� � 2x EAVE RAFTER CUT TO CURVE(MIN 31/2"DEPTI•)@ 16"O.C. x10 1 .C. HEADER,REFER TO —— -m ROOF FRAMING PLAN 2x4 JOISTS @ 16"O.C.,TYP. - I ____ OVERFRAME , N I' N - --� 2-2x CONT.STRUCT FASCIA, BLOCK DlAPHAGM ALONG I Ico __ s a� I ;I BEVELED TO ROOF SLOPE, -� ►W- of �' ci; ! TYP.AROUND EAVE LINE 1� PANEL EDGES.NAIL 1 I - - ___ _ SHEATHING TO BLOCKING J75 �� WITH 8d NAILS AT 6"O.C. S3.4 - `�� - - - W x 6 2x4 S U �LRIN WAL BEL W - - - - ~ o N w �I OVERFRAME JL J L JL JL _-_. — _ - k v �J �226i 3-2X1 _N J ---Q�- /Ftil 1 (O W r'V� ~ W- - ---0 -- AJ*1b t FASTEN 2-2x6 TO 4-2x6 POST WITH 6" o S - LONG TIMBERLOK SCREWS AT 12"0.C. `� J F` -OP G w n (MIN. 10 SCREWS) , t - — _ - - -- _ - BLOCK BENEATH DORMER WALLS PARALLEL TO 2x 0 @ i Of£ — — — w c� i- FRAMING, TYP. A `� J �0 K BE WEE JOISTS AT - - - - - to - 2x6 S UD BEARIN - �, c� w ��Q S�1 RWA PE 4/S3. . M -- __ W G WAALLBELOW Cb 1NU BLOC ING BAY MIN. -� i Jv� ►� --- J —- —— — BEYOND BEY ND E D 0 SH WA N p Uj Of `� x6 S UD 8 RIN WAL BEL cx \— � 3i fir- - --- --- W o 04 22" ?6�y I 2-2x6 STUD FASTENED TO o O =' ��� ADJACENT POST W/ A ~J „ 'p II FRAMING SCREWS o t�i J k DOUBLE UP JOISTS BENEATH cn o 04-1 m- 10 @ 16"0. - - _1 -- DORMER HEADER POSTS ABOVE, TYP. CD C SHEAR WALL ABOVE.BLOCK BETWEEN JOISTS BELOW J -- - - ww � P J B 7 3- '/+"L 24' LON CO INUO S w �� �L J11- JL JL JL JL JL J JL JL JL JL L -jI L.— v a S3.4 11 1r 1r 11r 1r 1r 1r 1r 1r 1r 1r 1r 1r 1r r 1r 1r I I"I O N Q -4,! - - - _ 11_ ' w J o I o W :o ", C6,) BLOCK BETWEEN FLOOR JOISTS AT G 10 16"0. O c RAFTER LOCATIONS,2 BAYS MIN FASTEN - __ _ SHEATHING TO BLOCKING WITH 8d NAILS ( �- AT 4'0.C., TYP.AT GAMBREL FRAMING �- _ QJ —— - Jr u m` LLJ � n O U WJ - .�\ /40 - - -"y ap., > 04 L J J L L 8 4-L 1r 1r 1 r 1r 1r 1r 1r 1r 1r 1r 1r -1F -1F -1r -1r 1r 1r fir- �•' �pa�i r`�� *''.`2x12 EDGE =,I w� p p p n 6�22�1 \ 10 \ 6 \ 2x12 @ 16 O.C. 0_SECOND FLOOR FRAMING PLAN BUILD OUT WALL CORNERW/2-2x6 �+ "�+ �+ FTE S TO POSITION HOLDOWN AWAY - IF FROM SUPERIOR WALL I- - - I j • 2x8 --- - -- --- - = T'�'L _ - `w•,-.: FOUNDATION EDGE =-- 10'-0 W00 ROOF FRAMING;REFER TO 24 11S1.2 U S7 3-2x8— z INSTALL 2-2x6 SOLE PLATE TO W \-n SUPPORT RAFTER ENDS WHEN ^ E r. 0 LANDING ON FLOOR FRAMING 0 U 2X12 TYP. 2x12 TYP. BELOW,TYP.(2 LOCATIONS) 4-J 0 U -————————— ———— ————--————————- Ri U �U' -————————— ———— ————--————————--- th 0 c" Uzi L J cr 0 E-4 aN IIIIIIIIII\o� IIIIII1II\S3 4IIIIIIIIIIIII\ti u�OJZ, -----iIIIIIIIIIIiII��-�\\2--------7-�G xIIIIIIIIIIII--------"`11 '\r----IIIIIIIIII---- O rVufW� 4 -------- 2 r2 2 S3.4 --—cy ————--————————- S3.4 2� U_ Ln ----- --- ------------ 0 _014- ——— "-4 2 0 V) Q� I -_j It 4-J OVERFRAME LOW ROOF FRAMING,REFER TO 11S1.2 LOW ROOF FRAMING;REFER TO 11S1.2 ----------- 2X12 TYP. 3-2)8 7 6 37�x6 -2x 6 "po 3 lit* 3-2x8 --------- -- - --------------- < 04 04 ———————— ————————--————————-- ck. BEAR VALLEY ON ASSOCIATES c". A ck, SHEAR WALL BaolW,*REFER TO DRORPED BEAM OVERFRAME 0'. 7. STRUCTURAL ENGINEER S S1.02 FOR POSTAIWD HOLDOWN 12 @ 16'0. SIZES AND NAIL SP)ACING RAFrERS T_I I I I ST Walnut Street Newton Centre,MA 02459 x12 16' C. IT--------------- - I T---," :3 C14 617.244.1612 tel .. .. . .... 12K12 16" �,C. i i i V.:P\-\ RA, TERS L I I 1 617.244.1732 fax 0 PTER I I I I I I I I i www.siegelassociates.com ............... 2x8LI 16-4c I I C. 2-2r 2 1 111200 11 16' . . . .............. .... .. ..... .......... .. j �EJILII JG JOI�TS ... .... 1 1 ICEILI Jr'GJO IS I I I I I ... .. .. - ­=4- 74 1 C f1LINC-IJOISf cc Joo- is N 0 SOrYCHIMNT .......... LV[ 2xl;IRIDG T BOA 2x RID�E BO�RD co __j 0� lep\\ C4 C14 D B3)1 2-16' r 10 N': 77 7-_'7 cl' ............ ....... -2X12 - —— —————————- 6 V. .... .. .. ..... . cr I I ILL S3.4 2b2@ J6'0. . ..... .... .. .. .. .. c" MASONRYCHIMNEY oo- . ..... RAFi�RS M ?X I 1 -1, 1 11 -%-\ I 1 5. 12 16" 1 1 1 1 1 v 1 1 *12 Q 16'0. 1 1 - , ::,-. I --------- Ic" ek, I RAJ ITER S I I I I I I I I I 'b I LU --y RAF FERS c; I L' - ----------- t2X1�kVlff 0 ME L 3 1�0.3 \A C, Z' N \\\\\\\ \\\-\\'N 11 1 1\ I\X A., \c'. Alb c4V X" 12x I\\\ •\�N _I_qyjq, a 2x8 1\1�MITEI \LLJ\�� 0 ---- -------- - B I �0. (i j \\\\\�\ \ ", ZW C14 04 LOW ROOF FRAMING,REFER TO LOWROOF FRAMING,REFER TO 11S1.2 0"V 11S1.2 ME OVERFRA S111 ---------- ------------------------ S3.4 ly _VA SHEAR wALL Bam,REFER To S3.4 S1.02 FOR POSTAAVD HOLDOM SIZES AND NAIL SP?ACING FASTEN 3-2X6 STUB POST TO BLOCK DIAPHRAGM AT PANEL EDGES. ADJACENT POST W((8)8- 2X12 TYP. SHEATHING TO BE A TTA CHED TO THE FZ - ---------------- LONG TIMBERLOK SCREWS r3 FRAMING WITH 8d NAILS AT 6"0.C. cc) cl� to ,S3.4 INSTALL 2-2X12 EACH END OF REGION 0 c! NOTED WITH DTT2Z HOLDOWN TO INSTALL 2-2x12 EACH END OF REGION R� Q POST BELOW(2 LOCATIONS) - ----------- NOTED.FASTEN 2-2x12 TO ADJCENT 'T SHEAR WALL STUDS(2 LOCATIONS). FASTEN 2-202 TO ADJCENT SHEAR I — 0k I . .1z cl� I � S .�4 WALL STUDS W1(3)%'0 x 6"LONG LAG C14 SCREWS AT EACH STUD ---------------- ------------------------- 41 BLOCK DIAPHRAGM AT PANEL EDGES. OR ----------------- SHEATHING TO BEA TTA CHED TO THE FRAMING WITH BdNAILSAT66O.C. U_ cr_ 0 2x12 TYP. cc - -------------- C1 ---------------- U_ 0 cn 0 2x BLOCKING BETWEEN JOISTS AT --- --------------------- DORMERS IN LINE MTH GAMBREL FOLD, TYP. Uj INSTALL 2-202 EACH END OF REGION C4 NOTED WITH HDU4 HOLDOWN TO B84M ------ -- --------------- C14 C14 M\12 BELOW(2 LOCATIONS) FASTEN TO END WALL C) ------------------------------ BLOCK DIAPHRAGM AT PANEL EDGES. C) A. SHEATHING TO BE ATTACHED TO THE FRAMING WITH 8d NAILS AT 6"0.C. ——————————— --————————-- 77� INSTALL 2-202 EACH END OF REGION Lp NOTED WITH DTT2Z HOLDOWN TO POST BELOW(2 LOCATIONS) (D ----- ------------------- -- ----------------- x0b '7� !�'---------ci _p_—,H-————4---------7 - I ; Nt ca \\Ad 1r_ n '0 Uj -----------�:v== cq--------------- U BLOCK DIAPHRAGM AT PANEL EDGES. ROOF FRAMING PLAN Scale: 9/4"= 1'-0" ���6 O Nx `- � -_----_-6_--_____>° ;--�---- --?-���----- \2-�x�\��N O SHEATHING TO BEA TTA CHED TO THE FRAMING WITH 8d NAILS AT 6"0.C. V; ---------- ------------------- p- C14 -------------- DORMERS IN LINE WITH GAMBREL -- --------I--------2x ------2x BLOCKING BETWEEN JOISTS AT FOLD, TYP. Z INSTALL 2-2x12 EACH END OF REGION ---------- -------------------- NOTED.FASTEN 2-202 TO ADJCENT SHEAR WALL STUDS W1(3)%"0 x 6" 0 ----- --------- --------- LONG LAG SCREWS AT EACH STUD —-------------- -------- k 3-24 2 _0 �O 4 G,REFER TO /T10PLOW ROOF FRAMIN 11S1.2 v ""'Ppo'SUPPORT LANDING V�0 6 BE rN r t A-2X12HDpR1. H ERF 14n "XI NAIL 2x6 END WALL BRACING TO THE SILL PLACE USING V J "PLYWOOD FLOOR SHEATHING °O %"PLYWOOD WALL 2x6 END WALL BRACING ALIGNED WITH SOLID SHEATHING j 2x6 STUD WALL BLOCKING W/(5)-10d NAILS TO SILL PLATE OR '/."PLYWOOD FLOOR SHEATHING O + • %"PLYWOOD WALL %"PLYWOOD WALL USE FRAMING STRAPS PER SUPERIOR WALLS / PLYWOOD WALL %"PLYWOOD FLOOR SHEATHING ' ' I SHEATHING '/+"PLYWOOD FLOOR SHEATHING SHEATHING SHEATHING w RECOMMENDATIONS 2x6 PT SILL PLATE FASTENED WITH 2x JOIST PER PLANS 2x6 STUD WALL 2x JOIST PER PLANS 2x6 STUD WALL %"0 GALV.BOLTS AND 2"x2"PLATE 2x JOIST PER PLANS 2x4 PT SILL PLATE FASTENED WITH p WASHERS @ 24"O.C. %"0 GALV.BOLTS AND 2`x2`PLATE 2x6 STUD WALL 2x JOIST PER PLANS O v FASTEN EACH JOISTS TO SILL PLATE W/(2) SOLID BLOCKING(3 BAYS MIN,)@ 48"O.C., 2x BLOCKING @ 16"O.C. WASHERS @ 24"0.C. — �" � 16d NAILS OR USE FRAMING STRAPS PER AND 12"FROM INTERIOR OF EACH CORNER TO MATCH FLOOR DEPTH p v 2x RIM BOARD SUPERIOR WALLS RECOMMENDATIONS 2x RIM BOARD W/(6)-10d NAILS THROUGH SUBFLOOR 1 INTO SOLID BLOCKING 2x RIM BOARD 4"CONCRETE SLAB ON °` U GRADE W/WWF � 2x1(0 PT SILL PLATE 2x10 PT SILL PLATE ' ' � 'i FASTENED WITH%"0 GALV. FASTENED WITH%'0 GALV. ', „ PREFABRICATED FOUNDATION " 4"CONCRETE SLAB ON BOLTS AND 2"x2"PLATE 1 BOLTS AND 2 x2 PLATE 1 \ I WALL SYSTEM BY WALL, II " 1 � + x x x • STEEL REINFORCED BOND BEAM N O WASHERS @ 24"O.C. WASHERS @ 24 O.C. 11 BY SUPERIOR WALLS Z4GADE W/WWF • " STEEL REINFORCED BOND BEAM • " ' STEEL REINFORCED BOND BEAM CRUSHED STONE ,. SEE DETAIL 1/S3.1 6 z I I BY SUPERIOR WALLS z I i BY SUPERIOR WALLS I I FILTER MEMBRANE ULATION PER ARCH FINISH GRADE I I FINISH GRADE I I CONCRETE STUD W/VERTICAL REBAR b Ln I I BY SUPERIOR WALLS �; CONCRETE STUD W/VERTICAL REBAR CONCRETE STUD W/VERTICAL REBAR I I \ \\ a —mb Ln BY SUPERIOR WALLS II BY SUPERIOR WALLS PREFABRICATED FACTORYAPPLIED INSULATION \/\/\/\/\/ O , I I I I FOUNDATION WALL SYSTEM THICKNESS PER ARCH PLANS // // PREFABRICATED FACTORYAPPLIED INSULATION, PREFABRICATED FACTORYAPPLIED ED INSULATION, BY SUPERIOR WALLS / / / / / - FOUNDATIOMI WALL SYSTEM THICKNESS PER ARCH PLANS FOUNDATION WALL SYSTEM THICKNESS PER ARCH PLANS STEEL REINFORCED FOOTING BEAM BY SUPERIOR WALLS BY SUPERIOR WALLS VIRGIN SOIL 101/4" I I 2'-0"MIN. BY SUPERIOR WALLS STEEL REINFORCED FOOTING BEAM STEEL REINFORCED FOOTING BEAM101/4" I /\/\j\/ Z-O"MIN. BYSUPERIOR WALLS Z-0MIN. BY SUPERIOR WALLS _x x x z CRUSHED STONE FOOTING N PER MANUFACTURER \\\�\\�\\\ w `\ \ \ N RECOMMENDATIONS TO k FROSTDEPTH PVCFTG. DRAINAROUND l ., PVCFTG.DRAINAROUND „; t / / / / / PERIMETER WI/FILTER FABRIC PERIMETER W/FILTER FABRIC - S INSULATION PER ARCH / / / / / a PVCFTG.DRAIN AROUND %\\\! _ - _� /j/j�/j� AROUND.DRAIN TO DAYLIGHT AROUND.DRAIN TO DAYLIGHT PERIMETER W/FILTER FABRIC s INSULATION PER ARCH INSULATION PER ARCH CRUSHED STONE FOOTING w a " PER MANUFACTURER 4"CONCRETE SLAB ON GRADE W/WWF AROUND.DRAIN TO DAYLIGHT =_ __ `j\\j\\/�\/ ASSOCIATES CRUSHED SiTONE FOOTING w 4"CONCRETE SLAB ON GRADE W/WWF CRUSHED STONE FOOTING w 4 CONCRETE SLAB ON GRADE W/WWF �/�j�j PER MANUFACTURER Co PER MANUFACTURER Co PER TO SLABS CONNECTOR,AS \/////� FROST DEPTH PER PLAN STRUCTURAL ENGINEERS RECOMMENDATIONS TO RECOMMENDATIONS TO REQUIRED,BY SUPERIOR WALLS ��/\//\// %// ///%// //�/%/%�//�//�\/i //\/• /\�/%/�� SLABS CONNECTOR,AS \/\\/�� \\/\\/\\/\\/\\/�\\/�\\/�\\/�\\/�\y�y\/�\\/� y��\/� 860 Walnut Street SLABS CONNECTOR,AS FROST,DEEPTH PER PLAN REQUIRED,BY SUPERIOR WALLS FROST,DEPTH PER PLAN REQUIRED,BY SUPERIOR WALLS Newton Centre,MA 02459 3'-0" 617.244.1 t REQUIRED WIDTH 617.244.17 2 32 fax x FDN PERPENDICULAR TO JOISTS 2 FDN PARALLEL TO JOISTS 3 FDN PERPENDICULAR TO JOISTS W/FRAMING SHELF www.siegelassociates.com 4 FROST PROTECTlONAT ABOVE GRADE BASEMENT Scale: 3/4"= 1'0" REFER TO DETAILS 1/S3.1& 2/S3.1 (THIS SHEET)FOR ELEMENTS NOT STEEL REINFORCED TOP OF STEM 2x STUD WALL BEYOND STEEL REINFORCED TOP OF STEM REFER TO DETAILS ELEM61S3.1ENTS & NOT IDENTIFIED IN THIS DETAIL + " WALL BY SUPERIOR WALLS WALL BY SUPERIOR WALLS (THIS SHEET)FOR ELEMENTS NOT W HDU POST PER PLAN /z PLYWOOD WALL SHEATHING IDENTIFIED IN THIS DETAIL z 2x6 EXTERIOR STUD WALL %"0 GARAGE SLAB RESTRAINT BOLT FOUNDATION WALL BEYOND + • ' n DESIGN OPTION. LOCATED CENTRALLY WITHIN THE TURNED BEND/ 0 ALL-THREAD ROD INTO Q ANCHORS FOR HDU4,HDU2,AND 2x6 PT PLATE W/%"0 DOWN EDGE OF GARAGE SLAB CONCRETE FLOOR @ 24"O.C. I DTT2Z HOLDOWNS MAY BE POST- ANCHOR BOLTS @ 4'--0"O.C. #3 CONT.REBAR 7v INSTALLED EPDXYANCHORS TO 6" THICKENED PRECAST FOUNDATION %"0 THREADED INSERT 4"CONCRETE SLAB W/WWF ON 4"CONCRETE SLAB W/WWF, HDU,SIZE PIER PLAN WALL SECTION. COMPACTED CRUSHED STONE DRIVEWAY PER ARCH HAUNCH TO 6"OVER WALL HDU,SIZE PER PLAN HDU POST PER PLAN ( J INSTALLED IN 6"LIFTS `./ VERTICAL BLOCKING BETWEEN a HDU2,DTT2ZANCHORS TO HAVE FLOORS UNDER HOEDOWN(POSTS ! o MINIMUM EMBEDMENT DEPTH OF 6" %a I DESIGN OPTION. a PREFABRICATED x x x x _____= —x ANCHORS FOR HDU4,HDU2 AND ' ' � _ -- DTT2Z HOEDOWNS MAYBE POST- _ = HDU4 ANCHORS TO HAVE MINIMUM FOUNDATION WALL SYSTEM _ f BY SUPERIOR WALLS .'4/1/5 w .•. INSTALLED EPDXY ANCHORS TO �/ • " EMBEDMENT DEPTH OF 12". � 8'MiN.GRA VEL OR CRUSHED STONE PREFABRICATED ' ' ' '`_ " - 8"MIN. GRAVEL OR CRUSHED STONE "'`' W" ; ` ' I THICKENED PRECAST FOUNDATION4"CONCRETE STEM WALL ' ' , ;.., "``iy:: �� _ PREFABRICATED II , /� FOUNDATION WALL SYSTEM it \ ,; ' rT� FOUNDATION WALL SYSTEM " `w i \i> PREFABRICATED — , x x x WALL SECTION. w I I ALL OTHER HDU ANCHORS TO BE Z I VERTICAL REBAR BY SUPERIOR WALILS BY SUPERIOR WALLS � • , �i VERTICAL REBAR BY SUPERIOR WALLS FOUNDATION WALL SYSTEM % a — BY SUPERIOR WALLS �, BY SUPERIOR WALLS II COUPLED TO THREADED RODS SET Z .� u �i II o , I HDU2,DTT2ZANCHORS TO HAVE „ IN PRECAST FOUNDATION MASS. THREADED FOOD PER ' I I " 4 THREADED ROD PER ' I ° MINIMUM EMBEDMENT DEPTH OF 6" (� I I ,' 4 CONCRETE STEM WALL \\ HOLDOWN UNIT SCHEDULE TO HOLDOWN UNIT SCHEDULE TO n BACICFILL I BACKFILL % H FOUNDATION.DETAIL BY REINFORCED PRECAST I I � �. /\� ' /�� FOUNDATION.DETAIL BY HDU4 ANCHORS TO HAVE MINIMUM (I ,\\ 'SUPERlOfR WALLS FOUNDATION MASS(AS REQUIRED) .O t .., ; �\� STEEL REINFORCED FOOTING BEAM STEEL REINFORCED FOOTING BEAM SUPERIOR WALLS EMBEDMENT DEPTH OF 12".l `f'�- , � • � - �. \�j\\ ' \/ BY SUPERIOR WALLS //, BY SUPERIOR WALLS 10114" II BY SUPERIOR WALLS \ //�� \ �„ .a' , \\j\ \\ i\//� //\/ i >'' � /\\/�\� ALL OTHER HDU ANCHORS TO BE �// � " �.-.�. -. -. -.��: �. -.- ' - //// /\/\ _-. k. _ i �. ,,.. � \��. '., � COUPLED TO THREADED RODS SET �%/\\%/ IN PRECAST FOUNDATION MASS. /�\/ \ \/ \ \ \ \ �\ „ y CRUSHED STONE FOOTING \ \ /\/\ CRUSHED STONE FOOTING �\ PER MANUFACTURER 101/4" PER MANUFACTURER 101/4" REINFORCED PRECAST /\\; " = RECOMMENDATIONS TO RECOMMENDATIONS TO ��/��� ii /��/�� FOUNDATION MASS(AS REQUIRED) A FROST DEPTH FROST DEPTH i//\// %\//, BY SUPERIOR WALLS �� CRUSHED STONE FOOTING CRUSHED STONE FOOTING Y %�r`\ �/ PER MANUFACTURER %\ PER MANUFACTURER RECOMMENDATIONS TO RECOMMENDATIONS TO FROST DEPTH x FROST DEPTH HOEDOWN AT BASEMENT WALL GARAGE FOUNDATION WALL SECTION GARAGE FOUNDTION WALL AT APRON HOEDOWN AT GARAGE FOUNDATION WALL Scale: 3/4"= 1`-0" Scale: 3/4"= 1=0" A PT DECKING w ~ w PT 2x JOIST PER PLANS Ar- 2x BEARING WALL PER PLANS BEAM PER PLANS "FLOOR SHEATHING ~ a ', ! SIMPS�ON LPC6Z POST CAP, LVL BEAM PER PLAN C14 INSTALL IN PAIRS CD 77 O A � SIMPSON ABA66Z POST BASE W/%"0 SIMPSON HANGER x 6"EMBEDMENT EPDXY ANCHOR SET W/HILTI HIT-HY 200 ADHESIVE FINISH GRADE O I FLOOR JOIST PER PLAN SIMPSON JOIST HANGER J W I I �- W U � CONCRETE PIER PER PLAN LALLY COLUMN PER PLAN W/ Cfj SPRINGFIELD CAP AND BASE PLATE THICKEN CONCRETE SLAB TO —� z TOP OF FOOTING AROUND 4 4"CONCRETE SLAB ON GRADE W/WWF COLUMN BASE rill N U A � x x x x x x x w z BELLED FOOTING I INSULATIONAS r f~ L ; M, REQUIRED BY ARCH. ,� �r-°"";4 CONCRETE FOOTING.SIZE& 2'-0" REINFORCING PER PLAN :(x �+a R ,. -A 1SOLATED PIER W/BELLED FOOTING DETAIL '� LALLY COLUMN DETAIL ;; Scale: 3/4"= 1'0" II --------------- %"PLYWOOD WALL '/."PLYWOOD FLOOR SHEATHING SHEATHING 00 U) 2x6 STUD WALL 2x JOIST PER PLANS.FOR PARALLEL %"PLYWOOD WALL %"PLYWOOD WALL JOISTS PROVIDE BLOCKING SIMILAR TO SHEATHING SHEATHING O 21S3.1 HEADER PER PLANS '/,"PLYWOOD FLOOR SHEATHING s " %"PLYWOOD WALL SIMPSON FACE MOUNT 2x6 STUD WALL 2x6 STUD WALL /+ PLYWOOD FLOOR SHEATHING uj SHEATHING %"PLYWOOD FLOOR SHEATHING 2x RIM BOARD JOIST HANGER >~ 2x RIM BOARD 2x JOIST PER PLANS.FOR 2x RIM BOARD 2x6 STUD WALL 2x JOIST PER PLANS.FOR PARALLEL 2x10 PT SILL PLATE JOIST PER PLANS.FOR -� +- PARALLEL JOISTS PROVIDE PARALLEL JOISTS PROVIDE -J JOISTS PROVIDE BLOCKING SIMILAR T u 21S3.1 BLOCKING SIMILAR TO BLOCKING SIMILAR TO 2/S3.1 21S3.1 ; HEADER PER PLANS A RIM BOARD _ EXTERIOR DECKING EXTERIOR DECKING 2x10 PT:StLL PLATE PER ARCH PER ARCH � � � REINFORCED BOND BEAM AT REINFORCED• 2x PT LEDGER BOLTED TO ti , " OPENING PER SUPERIOR WALLS BOND BEAM WITH ONE ROW OF/ 0 2x PT DECK JOISTS 2x PT PORCH GALV.THROUGH BOLTS AND 2"x2"PLATE PER PLANS !� JOISTS PER PLANS WALKOUT BASEMENT OPENING PER WASHERS @ 12"O.C.AND FASTENED TO �� ors® ARCH.DRAWINGS — RIM BD W/3-5/8"LEDGERLOKS AT 8"O.C. WINDOW OPENING PER I \ / I SIMPSON FACE MOUNT WATERPROOFING BYARCH n WATERPROOFING BYARCH If �„ p d��- I V I FILTER MEMBRANE , /� ��� ARCH.DRAWINGS I A I JOIST HANGER /� /`� / \ \ REMOVE INSULATION LOCALLY REMOVE INSULATION LOCALLY 0? Qjj PREFABRICATED FC)UNDATION I / I �j\\jam\jam\/\\/� FROM BEHIND PLATE WASHER FINISH GRADE FROM BEHIND PLATE WASHER WALL SYSTEM BY SUPERIOR WALL, \/\\/\\/\\/\\/ II SEE DETAIL 1153.1 _ ✓j\//\//\/j\//\ _ /�/ , PREFABRICATED FOUNDATION II 2x12 PT LEDGER BOLTED TO f n „ �j\ � \�\\\ WALL SYSTEM BY SUPERIOR WALL, (I FOUNDATION WALL WITH ONE II 2x12 PT LEDGER BOLTED TO ;�'`" �� I I FOUNDATION WALL WITH ONE FINISH GRADE AT BOTTOM >�\j\\/�\/\\ i\\j\\;\\j SEE DETAIL 1/S3.1 II ROW OF%"0 GALV.THROUGH II � BOLTS AND 2"x2"PLATE II ROW OF%"0 THROUGH BOLTS @ OF WINDDOW WELL II PREFABRICATED FOUNDATION (1 12"O.C.AND FASTENED TO RIM BD (V 2x10 PT PLATE FASTENED WITH FINISH GRADE I I WASHERS @ 12"0.C.AND I I I i I I WALL SYSTEM BY SUPERIOR WALL, Wl 3-5/8'LEDGERLOKS A T 8"0.C. I I / 0 GALV.BOLTS AND 2 x2" - ' " FASTENED TO RIM BD W/3-5/8" I I II SEE DETAIL 1/S3.1 PLATE WASHERS @ 24"O.C. - ; it LEDGERLOKS AT 8 O.C. I I NOTE:PROVIDE(2)%"0 THROUGH , II I I BOLTS AND(4)3-5/8"LEDGERLOKS ? - ° NOTE.PROVIDE(2)%"0 THROUGH AT BEAM CONNECTION FROST PROTECTION AT BOTTOM OF BOLTS AND(4)3-5/8"LEDGERLOKS LOCATIONS, TYP.SEE PLAN C AT BEAM CONNECTION ASSOCIATE.. FOUNDATION WALL IS SIMILAR TO LOCATIONS,TYP.SEE PLAN STRUCTURAL ENGINEER' BOTTOM OF FOUNDATION WALL IS SIMILAR DETAIL 4/S3.1 _ TO DETAILS 1/S3.1THROUGH 3/S3.1 860 Walnut StreetBOTTOM OF FOUNDATION WALL IS SIMILAR BOTTOM OF FOUNDATION WALL IS SIMILAR Newton Centre,MA 02459 TO DETAILS 1153.1 THROUGH 3/S3.1 TO DETAILS 1153.1 THROUGH 3/53.1 617,244.1612 tel 617.244.1732 fax �C HEADER SECTION AT BASEMENT OPENINGS www.siegelassociates.com HEADER SECT/0N AT BASEMENT WALKOUT DECK FRAMING AT FOUNDATION WALL PORCH FRAMING AT FOUNDATION WALL Scale: 3/4"= 9'0" PT DECKING CMU CHIMNEY ABOVE SOLID STONE HEARTH. PT DECK BEAM PER PLAN SIMPSON LPC6Z POST CAP SEE ARCH DWGS E STUD WALL I ARCH DWGS REINFORCED '/<"PLYWOOD FLOOR � I — V J CONCRETE SLAB SHEATHING PER PLAN / (� BEAM PER PLAN I I ( V J BEAM PER PLAN ;. I I I PT TIMBER POST PER PLAN #4 @ 12"O.C. "-r- BENT BARS (2)6"LONG TIMBERLOK SCREWS 16' oo" TO UNDERSIDE OF BEAM-PROVIDE ,�_ __I _ _ I - - I-- - 1"SPACING BETWEEN SCRE 1 D"CMU WALL 16" BENT BARS _-_- _ I — — — — — — — — AND 1'/."EDGE DISTANCE 16" #4 @ 12"O.C. WS FULLY GROUTED _ ; _ 16" I 10"CMU WALL - 12"CMU WALL I I FULLY GROUTED FULLY GROUTED 6x6 VERTICAL PT 77 TIMBER BRACE F�-1 %"0 BOLT WITH NUT AND CMU WALLS TO BE WASHER,TYP.ALL BRACED I CONNECTIONS TO POST ALIGNED UNDER CHIMNEY WALLS ABOVE I '^--- ABU66 POST BASE — — — — — — — — — — 4- — — — — — — — II CONCRETE PIER PER PLAN A I END POSTS I I INTERIOR POSTS lV V HEARTH SLAB DETAIL DECK BRACING DETAIL A W W A N v� �! w d CV WN O A 0 c Q W 0 I— ' U ; W � h U7 o U o 10d NAILS @ 3"O.C. 2x BLOCKING BETWEEN JOISTS �— a O FLOOR SHEATHING O " FLOOR JOIST CONTINUOUS ! 1 .� OVER WALL `.J � 0 F+ SIMPSON LTP5 PLATE FLOOR SHEATHING fs, AT EACH BLOCK FLOOR JOISTS < N � O WALL TOP PLATE `t 2x BLOCKING AT EAVE.BEVEL TOP TOE NAIL BLOCKING TO 2x BLOCKING BETWEEN 1-4 Ln OF BLOCKING TO MATCH ROOF TOP PLATE WITH 5-12d JOISTS,FLUSH W/WALL +- BLOCK ALL SHEATHING SLOPE.FASTEN ROOF SHEATHING NAILS PER BLOCK sy�T SEAMS. SHEATHINGLn TO BLOCKING WITH 8d NAILS @ 4" y�NG SIMPSON LTPS PLATE d' O.C.MIN.,U.N.O.ON PLANS BLOCKALL SHEATHING SEE PLAN NOTES FOR SF I — _� _—————— — —_ SEAMS q'L/ AT EACH BLOCK WOOD SHEAR WALL ! , • I � SHEAR PANEL LENGTH �", SIMPSON H2.5A HURRICANE TIE @ SEE PLAN NOTES FOR TYPICAL EACH RAFTER,U.N.O. ON PLAN T YPI CAL EDGE NAIL SPACING x CONNECTION CONNECTION �` AT ROOF x AT GAMBREL OFOBLOCKING TO MATCH ROOF CKING ATE4VE.BEVEL TOP N k SLOPE.FASTEN ROOF SHEATHING SHEAR WALL SHEATHING, SEE PLAN FOR SHEAR HDU POST PER PLAN 2-2x GAMBREL RAFTER NAIL SPACING PER PLAN PANEL LENGTH TO BLOCKING WITH 8d NAILS @ 4" O.C.MIN.,U.N.O.ON PLANS POST PER PLAN TOE NAIL BLOCKING TO NOTE.FOR TWO-SIDED SEE PLAN FOR EDGE TOP PLATE WITH 512d SHEARWALLS,PROVIDE 2x NAIL SPACING NAILS PER BLOCK BLOCKING,FASTENING,AND ASSOCIATES G —— —_ SIMPSON LTPS PLATE AT EACH STRUCTURAL ENGINEER' WHERE SHEATHING SEAMS SHEA THIN SEAM FACE OF SHEATHING INTERIOR SHEAR WALL 860 Walnut Street Newton Centre,MA 02459 OCCUR,SPACE6"MIN. � � :— --// — STUDSAND SHEATHING 617.244.1612 tel ABOVE OR BELOW PLATE t- HDU,SIZE PER PLAN PLAN HDU,SIZE PER 617.244.1732 fax SHEAR WALL PERPENDICULAR TO FLOOR JOISTS ABOVE INTERIOR SHEAR WALL DETAIL www.siegelassociates.com TYPICAL THRU TYPICAL CAL THRU 3 Scale: 3/4"= 1'0" 4 scale: 3i4"= 1'-0" FLOOR SHEATHING SEAM FLOOR SHEATHING SEAM __ —_ CONNECTION CONNECTION •• VERTICAL BLOCKING BETWEEN VERTICAL BLOCKING BETWEEN FLOORS UNDER HOLDOWN POSTS FLOORS UNDER HOEDOWN POSTS SEE PLAN FOR SHEAR SEE PLAN FOR SHEAR PANEL LENGTH k PANEL LENGTH k HDU,MATCH SIZE k k � HDU,MATCH SIZE r FROM FLOOR ABOVE SHEATHING SE z FROM FLOOR ABOVE SHEATHING SEA � h� SEE PLAN FOR EDGE WHERE SHEATHING SEAMS f "PLYWOOD SHEATHING AT SHEAR WALL W/BLOCKING @EDGES W/ NAIL SPACING OCCUR,SPACE 6"MIN. HDU POST PER PLAN ABOVE OR BELOW PLATE EDGE NAILING PER PLAN AND FIELD SEE PLAN FOR EDGE HDU POST PER PLAN NAILING PER GENERAL NOTES NAIL SPACING �i VERTICAL BLOCKING BETWEEN VERTICAL BLOCKING BETWEEN FLOORS UNDER HOLDOWN POSTS FLOORS UNDER HOLDOWN POSTS O BLOCK ALL SHEATHINGV) /� H x SEAMS %"PLYWOOD SHEATHING AT SHEARWALL W1 V J TYPICAL HDU,SIZE PER PLAN TYPICAL HDU,SIZE PER PLAN ; r k EDGE NAILING PER IPLANG NAND FIELD „• PER EDGES W1 PPLAN SON HOLDOWN CONNECCTION AT � + CONNECTION AT 'fir�i� SHEATHING SEAM — ———— NAILING PER GENERAL NOTES LVL BEAM PER PLAN FOUNDATION FOUNDATION (2)3/16'0 x 6'LONG TIMBERLOK SCREWS@ 16"0.C. (n rn PREFABRICATED ii II i i ii �H II FOUNDATION WALL SYSTEM THREADED ROD PER HOLDOWN �� PREFABRICATED BOUNDARY NAILING THREADED ROD PER HOLDOWN �i II BY SUPERIOR WALLS UNIT SCHEDULE TO FOUNDATION. �� II FOUNDATION WALL SYSTEM PER PLAN i n UNIT SCHEDULE FOUNDATION. BY SUPERIOR WALLS SHEATHING I'I DETAIL BY SUPERIOR WALLS �� II DETAIL BY SUPERIOR WALLS TWIST STRAP PER PLAN, THREADED ROD,SIZE PER V J EACH SIDE OF LVL HOLDOWN SCHEDULE 2x FLOOR JOISTS %"x3 z"x3%"PLATE WASHER, PER PLAN COUNTERSUNK A BEAM PER PLAN OR BLOCKING WHERE SHEARWALL IS PERPENDICULAR TO U FLOOR FRAMING W V MULTI-STORY SHEAR WALL SECTION MULTI-STORY SHEAR WALL SECTION AT GAMBREL SHEARWALL SHEAR CONNECTION TO LVL BEAM HOEDOWN CONNECTION TO LV'L BEAM DETAIL Scale: 3/4"= 1=0" Scale: 3/4"= 1.O" 5 6 Scale: 3/4"= 1=0" Scale: 3/4"= 1=0" A W W A W a N W O O A � M O c POST PER PLAN —J W DCTERIOR STUD WALL SHEAR WALL NAILING POSTS PER PLAN PER PLAN W %"SHEATHING,FIELD NAILS PER EDGE NAILING,SIZE PER EDGE NAILS,SIZE PER SHEAR WALL NOTES SHEAR WALL NOTES, ��— — — — — — SHEAR WALL NOTES, SPACING PER PLAN —I I %"SHEEATHING,FIELD NAILS PER SPACING PER PLAN CY_ WSHEAR WALL NOTES BUILT UP A CORNER — — — ° — FASTEN END STUD TO SIMPSON HOLDOWN PER PLAN SHEAR WALL POST WITH U '� r�j TIMBERLOK SCREWS AS ri SIMPSON HDU PER PLAN ° 1/2"SHEATHING,FIELD NAILS NOTED PER PLAN W PER,SHEAR WALL NOTES Of z INTERIOR SHEAR WALL SIMPSON HDU PER PLAN ku +� ( _��gE CORNER HOEDOWN DETAIL DOUBLE CORNER HOEDOWN DETAIL PLAN VIEW AT INTERIOR SHEAR WALL HOLDOWNS D Scale: 3/4"= 1'0" 8 Scale: 3/4"= 1'-0" 9 Scale: 3/4"= 1=0" VJ � 2x CEILING JOISTS PER 2x GAMBREL RAFTER PER PLAN PLAN,FASTEN TO RAFTER 2x BLOCKING BETWEEN JOISTS AT DORMERS IN LINE WITH p W/(8)16d NAILS rr ` GAMBREL FOLD.BEVEL TOP V W 2xe(MIN.)BLOCKING BETWEENV OF BLOCKING TO MATCH ROOF SLOPE.FASTEN ROOF SHEATHING TO BLOCKING � o CEILING JOISTS PER PLAN,FASTEN JOISTS AT DORMERS IN LINEO u TO RAFTER W/(4)16d NAILS WITH GAMBREL FOLD.BEVEL WITH 8d NAILS @ 6"0.C.MIN.TOP SIMPSON H2.5A ✓ ROOOSLOPE.FASTEN ROOF O F BLOCKING TO MATCH Zx CEILING JOISTS PER = F4 aJ —_—— HURRICANE TIE Ir'1 _ ———= SHEATHING TO BLOCKING PLAN,FASTEN TO RAFTER %'PLYWOOD ROOF 4 V / —— WITH 8d NAILS @ 6'O.C.MIN. W/(8) 16d NAILS SHEATHING SEE DETAIL 7/S3.4 ., U FOR ALTERNATE FRAMING 2x RAFTER PER PLAN 2x RAFTER PER PLAN N p j AT GAMBREL FOLD LINE — 2x ROOF RAFTER PER PLAN L.L SIMPSONA34 CONNECTOR � � %"PLYWOOD ROOF � TO 2-2x PLATE %N PLYWOOD ROOF SHEATHING,CONTINUOUS SHEATHING,CONTINUOUS OVER EAVE OVER EAVE 8d NAILS @ 6"O.C. cN p DOUBLE 2x12 CONT. TOP PLATE SIMPSON H2.5A SIMPSON H2.5A t` \ HURRICANE TIE ———_—— HURRICANE TIE EAVEEEOC IAFT � — BETWEEfJ RIAFTERS � ® J O _——— — SIMPSON H2.5A HURRICANE TIE 4-8d TOENAIL'LS PER BLOCK HEADER PER PLAN vn 2x6 TOP PLAI TE 2x6 STUD WALL /"PLYWOOLD WALL SHEATHING N GAMBREL ROOF LINE BEYOND �r N HEADER PER PLAN i E AVE BLOCKING PER DETAIL SAVE BLOCKING PER DETAIL S 4/S3.4 4/S3.4 2x GAMBREL RAFTER PER PLAN ASSOCIATES —~ "f STRUCTURAL ENGINEERS %"PLYWOOD ROOF SHEA THING, Walnut Stree t et CONTINUO US OVER SAVE 860_ 860New Wa Centre, etMA 02459 617.244.1612 tel NOMSTRUCTURAL ► 2x WALL 617.244.1732 fax www.siegelassociates.com DORMER ROOF SECTION - HIGH CEILING DORMER ROOF SECTION - LOW CEILING SAVE DETAIL W/0 CEILING JOISTS 2 Scale: 3/4"= 1'-0" 3 Scale: 3/4"= 1'-0" 4 Scale:- 3/4"= 1'-0" SIMPSONW.5A HURRICANE TIE W SIMPSON A34 r' 1 W CONNECTOR TO 2-2x SOLEPLATE SIMPSON A35 \ ONNECTOR Crsy� LVL RIDGE BEAM PER PLAN 2x GAMBREL RAFTER PER PLAN x L GE SIMPSON A35 ANGLE v CEILING JOISTS PER PLAN,FASTEN O x T2xRAFTER PER PLAN %'PLYWOOD ROOF SHEATHING 6 • TO RAFTER W/(4) 16d NAILS PLYWOOD ROOF CI' x HANGER SHEATHING rv�lJ F-1 1`. 2x RAFTER PER PLAN DOUBLE 2x CONT.PURUN(DEPTH C� (4)16d NAILS TO MATCH CEILING JOISTS) \ 8d NAILS@ 6"O.C. ------ ►-1 M+'1 3/4"PLYWOOD FLOORS SHEATHING , Zx EAVE BLOCKING BETWEEN RAFTERS H 2x FLOOR JOISTS PER PLAN ————-— 4-8d TOENAILS PER BLOCK %"PLYWOOD ROOF SHEATHING BLOCK BETWEEN FLOOR JOISTS SA!NOTES: AT RAFTER LOCATIONS,2 BAYS 2x EAVE JOISTS PER 1. CHANGE ROOF SLOPE PER ARCH DRAWINGS MIN.FASTEN SHEATHING TO PLAN,FASTEN TO BLOCKING WITH 8d NAILS AT 4" RAFTER W/(4) 10d NAILS 2x CEILING JOIST PER PLAN O.C., TYP.AT GAMBREL 2-2x6 TOP PLATE FRAMING 2x EAVE RAFTER CUT SIMPSON H2.5A HURRICANE TIE %'PLYWOOD WALL SHEATHING 1ST FLOOR TO CURVE,SEE PLAN A EXTERIOR WALL 2x6 STUD WALL 2-2x CONT.STRUCT FASCIA, THREE 8d TOENAILS EACH END V 1/2"PLYWOOD BEVELED TO ROOF SLOPE, TYP. W WALL SHEATHING AROUND EAVE LINE x V GAMBREL ROOF SECTION ALTERNATE GAMBREL FOLD DETAIL � LVL RIDGE BEAM DETAIL EAVE DETAIL W/CEILING JOISTS AT SHED A WLn W A v� N WN O O A M O Q � d- LLJ U NO � W � � N U � � W � z `�