HomeMy WebLinkAbout52533-Z hO�apf SOl/ryOlo Town of Southold
* * P.O. Box 1179
{o0 53095 Main Rd
U ff". Southold, New York 11971
CERTIFICATE OF OCCUPANCY
No: 47256 Date: 07/30/2026
THIS CERTIFIES that the building SINGLE FAMILY DWELLING-ALTERATION
Location of Property: 765 Madison St Greenvort, NY 11944
Sec/Block/Lot: 41.-1-2
Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 10/21/2025
Pursuant to which Building Permit No. 52533 and dated: 12/10/2025
Was issued, and conforms to all of the requirements of the applicable provisions of the law.
The occupancy for which this certificate is issued is:
Additions and alterations including a garage converted to a bedroom and a new covered
porch to an existing single-family dwelling.
The certificate is issued to: Matthew Charters ,Kaitlin Charters
Of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL:
ELECTRICAL CERTIFICATE: 52533 6/2/2026
PLUMBERS CERTIFICATION:
utho ' ed Si ature
i
"of sou TOWN OF SOUTHOLD
BUILDING DEPARTMENT
• SOUTHOLD, NY
cournr.�'
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 52533 Date: 12/10/2025
Permission is hereby granted to:
Matthew Charters
40 Madison St
Greenport, NY 11944
To:
Construct additions and alterations to an existing single-family dwelling to include garage conversion
to a bedroom with HVAC system,window and door replacements and new porch. Office is not to be
used as a bedroom.
Premises Located at:
765 Madison St, Greenport, NY 11944
SCTM#41.4-2
Pursuant to application dated 10/21/2025 and approved by the Building Inspector.
To expire on 12/10/2027.
Contractors:
Required Inspections:
Fees:
Single Family Dwelling- Addition&Alteration $484.00
CO Single Family Dwelling-Addition /Alteration $100.00
Total S584.00
--- � F)
Building Inspector
SO(/l�olo
Town Hall Annex Telephone(631)765-1802
54375 Main Road G
P.O.Box 1.179
Southold,New York 11971-0959 ��yCOUNTI,��
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATE OF ELECTRICAL COMPLIANCE
SITE LOCATION
Issued To: Matthew Charters
Address: 765 Madison St AKA 40 City: Greenport st: NY zip: 11944
Building Permit#: 52533 Section: 41 Block: 1 Lot: 2
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
Electrician: Retrofit Electric Inc License No: 60131ME
SITE DETAILS
Office Use Only
Commercial Indoor X Basement X Service X Solar
Residential X Outdoor X 1st Floor X Pool Battery Storage
As-built Renovation 2nd Floor Hot Tub EV Charger
New X Addition Attic Spa Generator
Survey Mezzanine Garage Dock
INVENTORY
Service 1 ph X In-wall Heater Recpt 6 Ceiling Fixtures Smoke Detectors 3 Pump
Service 3 ph Hot Water 30A GFCI Recpt 4 Wall Fixtures 2 CO Detectors Heater
Main Panel 200A A/C Condenser Single Recpt RecessdFixtures 13 Combo Smoke/CO 3 Transformer
Meter Main 200A A/C Blower Range Recpt Ceiling Fan 1 Heat Detectors Salt Gen
Transfer Switch Mini Split Dryer Recpt UC Lights Fridge AutoCover
ARC 2 Blower Heads Switches 7 Pucks Lights Dishwasher Mini Fridge
GFI SepticDisconnect Emrgency Strobe 4'LED Microwave Garbage Disp.
ARC/GFI ERV Exit Lights Bath Exhaust 1 Hood Dehumidifier
Other Equipment: 200A Panel 30 Circuit/27 Used
Notes: Garage Converted to Living and UG Service
Inspector Signature: Date: June 2, 2026
Town Hall Annex �� Gym Telephone(631)765-1802
54375 Main Road o
P.O. Box 1179 N 2
Southold, NY 11971-0959 W
•
I BUILDING DEPARTMENT
JUN - 8 2026 TOWN OF SOUTHOLD
Building Dnpartrnent
Town CERTIFICATION
Date:
Building Permit No. 3 3
Owner: VA0 t+hgeU) Z I-a j 4 I VI CV0X -P-r!5
[(Please print)
Plumber:' , %Iq
(Please print)
I certify that the solder used in the water supply system contains less than 2/10 of 1%lead.
/000
(Plumbers Signature)
Sworn to before me this
da r<< 20_law
Notary Public, _County
PAUL C CAPERNA
NOTARY PUBLIC,STATE OF NEW YORK
Registration No. 01 CA6151160
Qualified in Suffolk County Co 1
Commission Expires August 14,20 V?
ho�apF SOUTyolo � � w ✓ mot -
* # TOWN OF OUTHOLD BUILDING DEPT.
631-765-1802
INSPECTION
1
[ ] FOUNDATION 1ST/ REBAR ROUGH PLBG.
[ ] FOUNDATION 2ND ] INSULATION/CAULKING
[ ] FRAMING /STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL
REMARKS: a
C)k),IA��aA An
Pee �16 -luvlq�nq
ct, rf c
DATE ® INSPECTOR
ho��OF 50Ulyo�
* TOWN OF SOUTHOLD BUILDING DEPT.
ourm 631-765-1802
INSPECTION
[ FOU DATI N 1ST/ REBAR [ ] ROUGH PLBG.
[ ] UNDATION 2ND [ ] INSULATION/CAULKING
[ FRAMING /STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE C/O [ ]. RENTAL
E ARK : ' 4
IVA
DATE INSPECTOR
OF SO(/lyolo �W
# . * TOWN O OUTHOLD BUILDING DEPT.
00UN1V N�'io 631-765-1802 17
INSPECTION
[ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION/CAULKING
[ ] FRAMING /STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL
Ltv
REMARKS: �d
DATE INSPECTOR
ho�aOF SOpTh°!o
# TOWN OF SOUTHOLD BUILDING DEPT.
"Couto, 631-765-1802
��/5 INSPECTION
[ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] I ULATION/CAULKING
[ ] FRAMING /STRAPPING [ FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL
REMARKS: i
C�A
DATE ( p INSPECTOR
i
Armstrong Architecture and Planning
450 Cemetery Road,East Marion,11939
February 26,2026
Southold Town Building Department
54375 Main Road
NY Route-25
P.O.Box 1179
Southold,NY 11971
Reference:Charters Residence
40 Madison Street
Greenport,NY 11944
To Whom It May Concern:
The installation of insulation at the above referenced residence has been satisfactorily completed as indicated on the
approved permit drawings,and in compliance with all code requirements for The Town of Southold and The New York
State Energy Conservation Construction Code.
Best,
Brina Arms g,RA
�MST&O
C� _�P ti0 4( _
tY n�
Lli
' t
4 o6 g0 A: _T F � I.9 J U PJ 8 2026
EO
?, A
2025 RCNYS
R324.4.3 Glazing in Windows
Glazing in an individual fixed or operable panel that meets all of the following conditions shall be
considered to be a hazardous location:
1. The exposed area of an individual pane is larger than 9 square feet(0.836 mz).
2. The bottom edge of the glazing is less than 18 inches(457 mm)above the floor.
i
I . The top edge of the glazing is more than 36 inches(914 mm)above the floor.
4. One or more walking surfaces are within 36 inches(914 mm), measured horizontally and in a
straight line,of the glazing.
Exceptions:
1. Decorative glazing.
2. Where glazing is adjacent to a walking surface and a horizontal rail is installed 34 to 38 inches
(864 to 965 mm)above the walking surface.The rail shall be capable of withstanding a
horizontal load of 50 pounds per linear foot(730 N/m)without contacting the glass and have a
cross-sectional height of not less than 11/2 inches(38 mm).
3. _Outboard panes in insulating glass units and other multiple glazed pAnejs where the bottom._
edge of the glass is 25 feet(7620 mm)or more above grade, a roof,walking surfaces or other
horizontal [within 45 degrees (0.79 rad)of horizontal]surface adjacent to the glass exterior.
E E � � �
J U Pi - 8 2026
�,{ ,;rst! a9c3
MGm ail Sarabia Construction <francisco@sarabiahome.com>
Update on the Building Permit Application
Matt Charters <mcharters90@gmail.com> Mon, Dec 8 at 5:35 PM
To: Construction Sarabia <francisco@sarabiahome.com>
Cc: Kaitlin Charters <kaitlincharters@gmail.com>
Francisco:
See attached. Shed has been here since house was built or shortly there after and was here
/ shown when I got the solar on my house in 2022. 1 believe I have a sketch from the title
work when I bought the house that shows the shed application.
Not sure how the wetlands are impacted as none of our setbacks on that side are changing,
But it's over 100' from the house to the wetland.
CO attached.
Sent from my Phone
On Dec 8, 2025, at 5:07PM, Sarabia Construction
<francisco@sarabiahome.com> wrote:
[Quoted text hidden]
1978-z Charters CO.pdf
FIELD INSPECTION REPORT DATE COMMENTS
FOUNDATION (1ST)
\S,
------------------------------------
C
FOUNDATION (2ND) lk
uw y l
ROUGH FRAMING&
PLUMBING YA y
s
o.
1
� r
INSULATION PER N.Y. �3
STATE ENERGY CODE
G
r wl uw.
FINAL -. W
0
ADDITIONAL COMMENTS
g q # -1-�c) P 11388
ZeD 2'
oCv
fo -cl A
_ r
9.� b
o �
z
d
r�
b
o� 1701)"N UT SOU'1'HOLD— BUILDING DEPARTMENT
Town Hall Annex 54375 Main Read 1". U. Box 1179 Southold,BUY 1 1 971-0959
'rele hone(63 H 765-1302 Fax (631) 765-95 02 h�s;[fwww.sout hold toavnny
Date Received
►PPLECATI N FOR BUILDING PERMIT
I
Fur Office Use only +1- lT�C71
PERMIT NO.�� 3 5 Building Inspector._
Applications and fomis must be filled out in their entirety.Incomplete l
applications will not be accepted. Where the Applicant is not the owner,an
Owner's Authorization form(Page 2)shall be completed.
Date: iD l I y`
OWNER(S)OF PROPERTY:
Name: Matthew&Kaitlin Charters SCTM#1000- 41-1-2
Project Address: 40 Madison Street aka 756 Madison Street Greenport NY 11944
Phone#: 631-873-7315 Email:
Mcharters90@gmailcom
Mailing Address: 40 Madison Street,Greenport NY 11944
CONTACT PERSON:
Name: f 914hI CI-SGo 5f'P-14161*1
Mailing Address: �,� , by Y. :y F iqs-r R AP-liom
Phone#: `3 I_ -L�. , o r r 3 Email: u Sc0�5araloiAr'Lvme.Gown
DESIGN PROFESSIONAL INFORMATION:
Name: Armstrong Architecture&Planning
Mailing Address: 450 Cemetery Road,East Marion,NY 11939
Phone#:631-338-5325 Email: Brina.Affnstrongl2@gmaii.com g @gmailcom
CONTRACTOR INFORMATION:
Name, 5A Aiq b q Cxr4SMUC,-np/4 rme.
Mailing Address: .Q. QD -.e.f E AST 9�l0Iq tq 111301
Phone#: GN- 4 —0 I ' Email: wa-czd
ezaRz1oiakome.corn
DESCRIPTION OF PROPOSED CONSTRUCTION
t
❑New Structure ❑Addition CrAlteration ❑Repair ❑Demolition Estimated Cost of Project:
❑Other $ I Sly,v00.°i)
r
Will the lot be re-graded? ❑Yes FN0 Will excess fill be removed from premises? ❑Yes UNo
, 1
PROPERTY INFORMATION
xisting use of property: Ptr t wtc' " 1'Otrvte Intended use of property: r,(vv�vy �tryt,—
Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to
this property? OYes EIJ'No IF YES,PROVIDE A COPY.
i1 Chcck Box Adel'heading: The owner/contractor/design professional Is responsible for all drainage and storm water issues as provided by
Chapter Z36 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone
Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings,
additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,
housing code and regulations and to admit aulhorited inspectors on premises and In building(s)for necessary inspections.False statements made herein are
punishable as a Class A misdemeanor pursuant to Section 210.45 of the New Yoik State Penal Lava.
I
Application Submitted By(print name): 1-0 SC �. SOLY'CLIOI C. C Authorized Agent ❑Owner
I
Signature of Applicant: Date: t 011 q{ zS
V—CO N%ETUNkCH
STATE OF NEW YORK Notary Public,State of New York
No.01BU6185050
SS: Qualified In Suffolk County
COUNTY OF ) Commission'Expires April 14,.2.
I
Tose being duly sworn,deposes and says that(s)he is the applicant
(Name of individual signing_contract)above named,
(S)he is the COVV+1-0-G'4'
(Contractor,Agent,Corporate Officer,etc.)
of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief;and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this
i
l4f1 day of_�C P Q-P/� 20 c
;( Notary Public
PROPERTY OWNER AUTHORIZATION
(Where the applicant is not the owner)
i, Matthew&Kaif in charters residing at 40 Madison Street, Greenport NY 11944
do hereby authorize Sarabia Home Improvements to apply on
my behalf to the Tow t Id Building Department for approval as described herein.
10/10/2025
Ow 1-1Si re Date
1/7
hew Charters & Kaitlin Charters
Print Owner's Name
r
h�o�g�FFO�,�cOG
y� BUILDING DEPARTMENT-Electrical Inspector
* TOWN OF SOUTHOLD
oy • Town Hall Annex-54375 Main Road-PO Box 1179-Southold, NY 11971-0959
Telephone (631) 765-1802
Temporary Certificate # oZ Date a o1U '— 2026
Customer Name Electrician Name �1-e&bjcl
Address 7&Z Liq Q /Sl1h� /fie �' Phone a
e-mail e-mail 0 !6gfi Lv/I�c rygcQ.
Phone License# — 1p0 3
Size aaa A Phase / = Overhead Underground #of Meters
Remarks
#of Underground Laterals 1 2 New
"H" Frame or Pole H P Fire Reconnect
Was work done on Service? Y/ Flood Reconnect
Old Meter# Service Reconnected
Application for electrical service equipment is on file with the town of Southold.On the applicant's notification that this installation
is complete,the town will conduct a premises inspection of the service equipment.
This verification is valid for 90 da s from the date above.
Authorized by /
� ±m,�.
liUIL;DING DEPARTMENT- Electrical Inspector
i TOWN OF SOUTHOLD
ear.
FEB 2 2Town Hall Annex- 54375 Main Road - PO Box 1179
Southold, New York 11971-0959
�yTelephone (631) 765-.1802
I
`:"•,ems, .-,:':c�" ,
APPLICATION FOR ELECTRICAL INSPECTION
ELECTRICIAN INFORMATION (All Information Required) Date: ;LJ2,02 2
Company Name: 10 kc •C
Electrician's Name: A p,\ M `k.GS _
License No.: M� : _4p0 V6 Elec. email:
Elec. Phone No: b l- p2, y, EE34 request an ema copy of Certificate of Compliance
Elec. Address.: t3 c>gvC N IL
JOB SITE INFORMATION (All Information Required)
Name: e,
Address: h ST ' VC a
Cross Street:
Phone No.:
Bldg.Permit#: email:
Tax Map District: 1000 Section: Block: I Lot:
BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly):
6 P41> CvC\v¢,)YS J0() &,u de r v�`� UeC)rV�Af
Square Footage: coo Pr
Circle All That Apply:
Is job ready for inspection?: L7] YES ❑ NO Rough In ❑ Final
Do you need a Temp Certificate?: ii] . I
YES ❑ NO Issued On c15"2
Temp Information: (All information required)
Service Size01 Ph❑3 Ph Size: �_A # Meters Old Meter#
❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect[OUnderground❑Overhead
# Underground Laterals 1 , 2 R H Frame Pole Work done on Service? Y
Additional Information:
PAYMENT DUE WITH APPLICATION
� - jib_� 2ro ;up
PERMIT# Address:
Switches
i
Outlets
GFI's
Surface
Sconces
H H's
C Lts Frid a HW -POOL
U g 4
Panel
Fans Mini Fr. - W/D Pump
Exhaust Oven Sump Heater
..Trnsfmr
Smokes DW Generator Salt Gen.
I I,
Water Bond
Carbc(n M.i.cro G.rb.Dis Lights
Heat Pucks ERV
HOT TUB/SPA
Inst Hot DeHum Transfer Disc
Combo ' % Cooktop M'inispIit Blower
AC AH Hood
Blower
Service Am Use
Have Amps ��"� d
�- ,
Sub Amps Have Used
Comments
SURVEY OF:
PROPERTY LOCATED AT GREENPORT
TOWN OF SOUTHOLD
SUFFOLK COUNTY. NEW YORK
S.C.T.M. # 1000-41-1-2
SCALE: 1"=30'
NOTE: THE EXISTENCE OF RIGHT OF WAYS,
WETLANDS AND/OR EASEMENTS OF RECORD
IF ANY. NOT SHOWN ARE NOT GUARANTEED.
LAND N/F
TOWN OF SOUTHOLD
LAND N/F
TOWN OF SOUTHOLD
N 60 06 41 FENCE
\ $rJ•� E FENCE 0.5'/w
WtR 1.0�5
f
m
CONC. m
MON. Z
m
m cn_3
' m
0
AC
v UNIT =
9G ® rn
o O
OQO�C/ zez sI N 0
'� �V - e SHED (P o LAND N/F
3.2'/W
coNc. n co W IOANNIS
F--� Z WAI-K rn m� a CE O MILONAKIS
-0 a y r
W CP A
9 W 5. = 4.9 o m FENCE
L 2�' 0.6'/E
�N NN
o, 25.41 C �jy
rn w 18.3 `P� !d y� �"0
�
co
J 14.3
X
r
cNo f m \v 0.507a2 J�
AND s�0.
PIPE
S 87°36'50' CONC.
POLE 60.84'
WILMARTH AVENUE
UNAUTHORIZED ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION
OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW.
COPIES OF THIS SURVEY MAP NOT BEARING THE LAND SURVEYORS INKED
OR EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY.
GUARANTEES OR CERTIFICATIONS INDICATED HEREON SHALL RUN ONLY TO
THE PERSON FOR WHOM THE SURVEY IS PREPARED.AND ON HIS BEHALF TO
THE TITLE COMPANY.GOVERNMENTAL AGENCY AND LENDING INSTITUTION SURVEYED B Y:
LISTED HEREON.AND TO THE ASSIGNEES OF THE LENDING
GUARANTEES OR CERTIFICATIONS ARE NOT TRANSFERABLE TO INSTITUTION.
ADDITIONAL P A U L B A R Y L S K I LAND SURVEYING
INSTITUTIONS OR SUBSEQUENT OWNERS. P A T C H O G U E NY 11772
CERTIFIED TO: PHONE 631-294-6965
MATTHEW CHARTERS FAX 631-627-3186
KAITLIN DANIELS CHARTERS PAULBARYLSKIiaYAHOO.COM
FIDELITY NATIONAL TITLE COMPANY JUNE 15. 2020
10-15-2025: PROPOSED PORCH
4136-P
T
.P
KII
Compliance Certificate
Project Information
Project Title: 40 Madison Street Residence
Energy Code: 2018 IECC
Location: Southold,New York
Construction Type: Single Family
Project Type: Alteration
Project Sub Type: None
Climate Zone: 4a(5572 HDD)
Project No: 1767920
All Electric: false
Is Renewable: false
Has Battery: false
Has Charger: false
Has Heat Pump false
Construction Site: Owner/Agent: Designer/Contractor:
40 Madison Street Charters Armstong Architecture&Planning
Greenport,New York 11944 40 Madison Street
Greenport,New York 11944
Project Notes:
Report Title: 40 Madison Street Residence Report Date: 10/7/25, 4:16 PM 1 of 11
Envelope Assemblies
Prop. Req.
Assembly Gross Area or Cavity Cont. U- U- Prop. Req.
Perimeter R Value R Value Factor/ Factor/ UA UA
F-Factor . F-Factor
Ceiling:Flat Ceiling or --- --- --- --- --- --- --
Scissor Truss
Exemption:Framing cavity
not exposed.
Wall:Wood Frame,16"o.c. ---
Exemption:Framing cavity
filled with insulation
Windows:Wood Frame 173 0.290 0.320 50 55
SHGC:0.28
Front Door:Glass Door(over 20 0.320 0.320 6 6
50%glazing)
SHGC:0.05
Back Door:Glass Door(over 19 0.320 0.320 6 6
50%glazing)
SHGC:0.05
Basement Wall:Masonry --- --- --- ---
Block w/Empty Cells
Wall height:0.00
Insulation depth:0.00'
Insulation position:Integral
Insulation
Exemption:Framing cavity
not exposed.
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.It DOES
NOT provide an estimate of energy use or cost relative to'a minimum-code home.
Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck.Each slab-on-grade
assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements.
Compliance Statement
The proposed building design described here is consistent with the building plans,specifications,and other calculations
submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in
REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
t tSps PXM sluNdn'
(Name -Title Sign 6tj4 Date
Report Title: 40 Madison Street Residence Report Date: 10/7/25, 4:16 PM 2 of 11
r
Inspection Checklist
Energy Code:2018 IECC
Requirements:0%were addressed directly in the RESCheck software
Text in the"Comments/Assumptions"column is provided by the user in the REScheck Requirements screen.For each
requirement,the user certifies that a code requirement will be met and how that is documented,or that an exception is being
claimed.Where compliance is itemized in a separate table,a reference to that table is provided.
Pre-Inspection/Plan Review
Section j.., l Plaris l `Field
# Verified .s Verified' 1
&&"Re Pre inspection/Plan Review Value Value, ! `Complies? „ Comments/Assumptions
103.1, Construction drawings and Complies
103.2 documentation demonstrate Does Not
[PR1]1 I energy code compliance for the []
I building envelope.Thermal Comply
envelope represented on [2 Not
construction documents. servable
ei
Not
Applicable
i
103.1, Construction drawings and Cj Complies I
103.2, documentation demonstrate
403.7 energy code compliance for d a Does Not
[PR3]1 lighting and mechanical _ �q,i�o omply
systems.Systems serving Not
multiple dwelling units must servable
demonstrate compliance with Not
the IECC Commercial Provisions
pplicable
:3021, " Heating and cooling equipment Heating: Heating: Q Complies
403.7. ;. is sized per ACCA Manual 5 Btu/hr Btu/hr Does Not
[pR2]r based on loads calculated per ❑
ACCA Manual I or other methods 0 Umply
approved by the code official. Cooling: Cooling: Not
- + Btu/hr Btu/hr servable
P Not
!I j�p'plicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2,° Medium Impact(Tier 2) 3"; ' Low Impact(Tier 3)
Report Title: 40 Madison Street Residence Report Date: 10/7/25, 4:16 PM 3 of 11
' r
Foundation inspection _
$eCtio0 Pianst
Foundation Inspection Value VaiuComplies� Comronts!Assumptions
303 2 1 A protective covering is r 0 Complies
[FOl�jz installed to protect exposed -
�` cr #axmin mum of 6 in.below grade. j " IDo
ior insulation and extends M, � Pmply Not
servable
� PNot
R h Pp
l;cable
n . t
403 9" Snow-and ice-melting system Complies
[FO12]z {controls installed.
_ 0, P � _ (�Does Not
OM
�" �21 ri ComPIY
a Q
Not
Observable
{]Not
'au '� Applicable
402.1.1+ Conditioned basement wall -1 ( 1 Complies See the Envelope
[FO4]' insulation R-value.Where R R Assemblies table for
interior insulation is used, Does Not values
verification may need to occur R R-E= omply
during Insulation Inspection.Not Not
required in warm-humid servable
locations in Climate Zone 3. Not
pplicable
303.2 !Conditioned basement wall Complies
[FO511 insulation installed per -= Does Not
manufacturer's instructions. (]
P R�� Comply
Not
servable
Not
pplicable
k
402.2.9 i Conditioned basement wall ft ft O Complies See the Envelope
[FO611 insulation depth of burial or Q Assemblies table for
i distance from top of wall. C mply Not values
Ob Not
servable ;
I Not
Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) Medium Impact(Tier 2) Low Impact(Tier 3)
Report Title: 40 Madison Street Residence Report Date: 10/7/25, 4:16 PM 4 of 11
.. Framing / Rough-in Inspection
o, qr v , v ad �� ti _ a' i, _ - 3
Se t On Plans Feeld
verified i verified
(, Framing/Roug i to ,b
si Rec toinspection� �� v �ue j vauuQ Gsmpiies�K = I Gom�n�nfislAsuropt�ons
Ia
402.1.1, Glazing U-factor(area-weighted 1 []Complies See the Envelope
402.3.1, ?average). U= U Does Not Assemblies table for
402.3.3, values.
402.5 Comply
[FR211 []Not
Observable
Ppp Not `
i licable
402.4.1,1 Air barrier and thermal barrier „m �gm 0 Complies
[FR23]1 installed per manufacturer's �. hrro
instructions. ,; Does Not
iQ
omply
9Not
r
GqP a servable
I
.0 Not
Applicable
402.4.3 i Fenestration that is not site built �^A ��O Complies
[FR20]1 is listed and labeled as meeting fi�` u
AAMA/WDMA/CSA 3Pt ( Does Not
101/I.S.2/A440 or has infiltration `r �.. :comply
rates per NFRC 400 that do not ❑Not
i exceed code limits. �}[yu Observable
I ° 9r;€ h
' Not
� . .
a pplicable
771,
402 4: IC-rated recessed lighting511 Complies
[FR161� 1 fixtures sealed at
1 r (]Does Not
housing/interior finish and "
labeled to indicate<_2.0 cfm l 9 a Comply
leakage at 75 Pa. F r; Not
u Q � k ar servable
0 Not
Applicable
."
,a,
403.3.1 iSupply and return ducts in attics v+�1 � Q Complies .
insulated>=R-8 where duct is „ ,�
[FR12] i>=3 inches in diameter andYt
a (]Does Not
li>=R-6 where<3 inches. ( � Ui��,& Comply
Supply and return ducts in other ❑Not
portions of the building { n NM servable
insulated>=R-6 for diameter
>=3 inches and R-4.2 for<3 " (�Not
inches in diameter, i G Applicable
403.3.2 Ducts,air handlers and filter ^ �� Complies
1 boxes are sealed with
[FR13] I mr Does Not
joints/seams compliant with
nternational Mechanical Code �r � % Comply
i or International Residential (�Not
Code,as applicable. a �� 9servable
n
� w a; O Not i
Applicable
403:3.5 Building cavities are not used as Complies
(FR1513 )ducts or plenums. , Does Not
k "i+t5 x� vti'`iN 44 XY*46(]
Comply
AI� � n Not �
VIrObservable
(]Not
Applicable !
403.3.6(1 Ducts partially or completely a t �111
O Complies
2)[FR26]3 buried in ceilinginsulation have
an insulation R alue not less F ���, �r� i(�Does Not
than R-8,the sum of the ceiling Comply
insulation R-value against and Not
above the top of the duct,and g ' servable
against and below the bottom of EE �� [
I the duct,is>=than R-19, Not
excluding the R-value of the E 1 �. AAppplicable
, ]duct insulation.
Report Title: 40 Madison Street Residence Report Date: 10/7/25, 4:16 PM 5 of 11
j
Section Plans Field ��
#' Framing/Raugh In vee-i etl Verified I a6, t 4
&Req ID i 11 coon „^ Value Value Complies? g Commentslpssur�pt�ons"
gt 403 3,7 Ducts declared to be within the a° "a�" , 0 Complies
([FR28]3 conditioned space are either 1)
(( completely within the (]Does Not
continuous air barrier and within ( j Comply
the building thermal envelope, I [�Not
{2)buried within ceiling i 06servable
insulation in accordance with r e aafii' ' ,
�]Section R403.3.6 and the air Not
handler is located completely k � a Applicable
within the continuous air barrier
and within the building thermals
envelope and the duct leakage
is<=1.5 cfm/100 square feet ` wH
of conditioned floor area served
by the duct system,or 3)the
ceilingg insulation R-value m
i installed against and above the t "
9 � `
insulated duct>=to the
i I
I proposed ceiling insulation R- f `
value,less the R-value of the
insulation on the duct . ' 5
403 4 Nw a ;HVAC piping conveying fluids (= R(� 0 Complies
above 105-F or chilled fluids l__J
{below 55 QF are insulated to aR- (]Does Not
(E 3• Comply
i nNot
j �iservable
Not
pplicable i
403.4.1 Protection of insulation on HVAC w '` a"°�[i 0 Complies
[FR24]1 #piping. C Does Not
j p(p v 't ,M "Na11 omply
j
�i (�]Not
s Eiservable
is i�Not
plicable
403 5.3 S Hot water pipes are insulated to R R= 0 Complies
[FR181? aR-3.
(�]Does Not
[ 3 Comply
Not
$ servable
Not
, ����� •., pplicable
403 6`" Automatic or gravity dampers 0 Complies
[FR0 are installed on all outdoor air
intakes and exhausts. Does Not
,aj """ -"•I 4r':m {,° j^,"zP l� '�*,� ii Comply
lj r ' �Not
ear m� xo OTiservable
s(
Not
pplicable I
ttr
[FR4]13 I products arefdetermined in 4+n a )�idfi ,i� '0 Complies
accordance with the NFRC test (]Does Not
procedure or taken from the Comply
I default table. 4 [�Not
servable
ONot
licable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2, °;? Medium Impact(Tier 2) 3 °` Low Impact(Tier 3)
Report Title: 40 Madison Street Residence Report Date: 10/7/25, 4:16 PM 6 of 11
Insulation Inspection
Section t Plans Field
Verified Verified i
&Req IDS _ • Insulatwn Inspection,` Value Value Complies? Comments/Assumptions,
303.1 All Installed insulation is labeled ❑Complies
[IN or the Installed R-values $ Does Not
1 provided.
i omply
Not
servable
Not
k.
pplicable
P
402.1.1, Wall Insulation R-value.If this is I = R ❑Complies See the Envelope
402.2.5, a mass wall with at least 1/2 of R Assemblies table for
402.2.6 the wall insulation on the wall ❑Wood ❑Woodn Does Not i values
[IN3]1 exterior,the exterior insulation Mass Mass `�"mply
requirement applies(FR10). ❑ ❑ ❑Not
❑Steel ❑Steel Observable
PI
{ plicable
303.2 Wall insulation is installed per Complies
[IN4]1 i manufacturer's instructions.
PoDoes Not
mply
I Not
i Observable
PNot
pplicable
�. 4
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3.;, Low Impact(Tier 3)
Report Title: 40 Madison Street Residence Report Date: 10/7/25, 4:16 PM 7 of 11
Final Inspection Provisions
�' riL�R 4u'^''
7xm ��ilRpe �le'rified Verified) a i
, l
&Iteq ID Penal Inspecf3on Rriovisions Value Value mCompi es? GOmmer tsfkssu�iip>ripns I
�.402.1.1, Ceiling insulation R-value. R� R f� ❑Complies ;See the Envelope
402.2.1, 1� Assemblies table for
402.2.2, ❑Wood ❑Wood Does Not values
Um ply
[Fill' 6 I ❑Steel ❑Steel []Not
Observable
Q Not
Applicable
303.1.1.1, Ceiling insulation installed per -0 a t �'" ❑Complies
303.2 manufacturer's instructions. i `'
[FI211 j Blown insulation marked every Does Not
1 300 ft-. { " Comply
Not
servable
Not
Applicable
a.. .
403 1;2 Heat pump thermostat installed n �$� Complies
❑
(F1101z 1 on heat pumps. ,
Does Not
Comply
[ Nip"I Not
1 R NO �' servable
, ❑Not
Applicable
403�5:1 Circulating service hot watery ❑Complies
systems have automatic or 1 u
accessible manual controls. �]Does Not II
Comply
a �� ` � , ❑Not
Observable
,.
❑Not
Applicable
4036:1 All mechanical ventilation [ �� S ❑Complies
+[F12512 system fans not part of tested
" and listed HVAC equipment 3 �1 Does Not
meet efficacyy and air flow limits '�, :? omply
per Table R403.6.1. + Not
Observable
�fi ��iah r ❑Not
Applicable
m ffl�
Hot water boilers supplying heat E �ti � ❑Complies
[FI261z ^ through one-or two-pipe ' Does Not
heating systems have outdoor r '
setback control to lower boiler s a �' , omply
water temperature based on Not `
outdoor temperature. ,Ica 9servable
Not
Applicable
403.5:1 1 1 Heated water circulation + , :❑Complies
[P128]2
systems have a circulation
pump.The system return pipe is Does Not
!a dedicated return pipe or a �'�, k� �a��„Comply
cold water supply pipe:Gravity k Not
and thermos-syphon circulation h servable
systems are not present.
Controls for circulating hot f Not
water system pumps start the ���r APPlicable
�t pump with signal for hot water
Id emand within the occupancy. n'
Controls automatically turn off
"Al, the pump when water is in f �
circulation loop is at set-point r �x
'temperature and no demand for
l hot water exists. „
403 5`°1 2 Electric heat trace syystems ^_ ':r ❑Complies
[FI29J2 comply with IEEE 515 1 or UL Does Not I
515.Controls automatically ��j d
" adjust the energy input to the 3 Po ply f
heat tracing to maintain the [�Not
w ;desired water temperature in P v servable
i the piping. ' r-1 Not
pplicable
Report Title: 40 Madison Street Residence Report Date: 10/7/25, 4:16 PM 8 of 11
1 /
Section plans `}� Field I
Verified [ verified ( r .�,_ ....�....... .
&Req ID I Final Inspection Provisions Value �t Value Complies? 'E Comments/Assumptions
4
403 5,2 %Demand recirculation water Complies
[FI30]2 systems have controls that
manage operation of the pump []Does Not
wader enta�fntethe cold waterhe '' w` Comply
9 R (y��'�Not
a piping to<=1049Ea4ra„ aG � UDservable
I gJ
Not
.: lppplicable
403,54 Drain water heat recovery units �� Complies
[FI31]2 tested in accordance with CSA
B55.1.Potable water-side (]Does Not
pressure loss of drain water f Comply
°]heat recovery units<3 psi for Not
individual units connected to Mservable
one or two showers.Potable r Not
water-side pressure loss of drain
water heat recovery units<2r Applicable
psi for individual units
connected to three or more a„
showers.
404.1 90%or more of permanent +yr Complies
[F16]1 fixtures have high efficacy ,�, �
lamps. `,� Does Not
'
s "i omply
u 9Not
I
6bservable
14 [�Not
i pplicable
(
404.1.1 Fuel gas lighting[systems haveCJ Complies
[F]23]3, no continuous pilot light. Does Not
t Pmply
[]Not .
Observable
'i �� tS°x2t
Not
i w 3 s
r ,au A-
pplicable
.[Compliance certificate posted, 0 Complies
2
[FI7] ' { s n�'� �, Does Not
Comply
[]Not
Observable
j° [jNot
Pplicable
303.3, Manufacturer manuals for Complies
[F]18]3 I mechanical and water heating ` t
systems have been provided. o�Does Not
[�Not
a" servable
j [ A�Not
pplicable
Ne
402 2. Vented attics with air_permeable
baffle
0 Complies
[FI22]z,~ insulation include ba aM t Does Not
adjacent to soffit and eave +
vents that extends over Comply
insulation. 4 ❑Not
0 servable
1 a ('�Not .
Oplicable
[Fl3i' 4 insulation zR value and R�-1 R�1~ Complies
[FI3] 1 adjacent assembly. �J �-1 Does Not
Comply
(('�]]Not
!! 1iservable
[]Not
P plicable
[F11711.2 Blower door test@ n s Pa.<=5 AC AC Complies
[FI17]1 I ach in Climate Zones 1-2,and ( �Does Not
<=3 ach in Climate Zones 3-8. omply
[]Not
I Observable
` Not
I pplicable
Report Title: 40 Madison Street Residence Report Date: 10/7/25, 4:16 PM 9 of 11
1 �
Field
#; Verified gg Verifletl"
&Req ID Final Inspection Provisions 1,
Value n a$ Value j ,,',Complies? Comments/Assumptions=
403.3.3 I Ducts are pressure tested to O Complies
(FI27]1 determine air leakage with 1
either:Rough-in test:Total cfm/100 ft2 cfm/100 ft2 (]Does Not
leakage measured with a Comply
1�pressure differential of 0.1 inch ((��Not
1 w.g.across the system including Pservable
1 the manufacturer's air handler
j enclosure if installed at time of [[]]Not
I test.Postconstruction test:Total Applicable
leakage measured with a
pressure differential of 0.1 inch r
w.g.across the entire system
including the manufacturer's air j
handler enclosure. i
403.3.4 Duct tightness test result of O I 1 Q Complies
[FI4]1 <=4 cfm/100 ft2 across the
system or<=3 cfm/100 ft2 cfm/100 ft2 cfm/100 ft2 []Does Not
without air handler @ 25 Pa,For Comply
rough-in tests,verification may Not
(�
need to occur during Framing servable
Inspection. I
Not I
pplicable
403.3.2.1 Air handler leakage designated ` e Complies
[FI24]1 by manufacturer at<=2/o of
design air flow. Does Not
11 Comply
[]Not
Observable
PNot
plicable
403.1. " {Programmable thermostats Q Complies
[F19]2 _;�Installed for control of primary
heating and cooling systems (]Does Not
and initially set by manufacturer Comply
to code specifications. (�Not
servable
e []Not
Applicable
Additional Comments/Assumptions:
1 1 High Impact(Tier 1) 2°'�` Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Report Title: 40 Madison Street Residence Report Date: 10/7/25, 4:16 PM 10 of 11
EnergyJr
Efficiency
Certificate
Above-Grade Wall 0.00
Below-Grade Wall 0.00
Floor 0.00
Ceiling/Roof 0.00
Ductwork(unconditioned spaces):
Window 0.29 0.28
Door 0.32 0.05
Skylight 0.00
® ..
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments:
Report Title: 40 Madison Street Residence Report Date: 10/7/25, 4:16 PM 11 of 11
-Ro
ad
COMPLY WITH ALL CODES OF APPROVED AS NOTED
NEW YORK STATE&TOWN CODES _]a_(�_ 5a 5 33
AS REQUIRED AND CONDITIONS OF DATE•=Bq'
0�5 B.P.#FE0 BY:_dA _
SOUP.OIDTOV.TI U'Nli+u BOARS NOTIFY BUILDING DEPARTMENT AT
.r..�...SOUiHOIDn"'ITRUSTM 631-765-1802 8AM TO4PM FOR THE
us.DIG FOLLOWING INSPECTIONS:
SOUTHOIDIrC FOUNDATION-TWO REQUIRED
SCHO FOR POURED CONCRETE
ROUGH-FRAMING&PLUMBING
INSULATION
FINAL-CONSTRUCTION MUST
ELECTRICAL BE COMPLETE FOR C.O.
INSPECTION REQUIRED ALL CONSTRUCTION SHALL MEET THE
REQUIREMENTS OF THE CODES OF NEW
YORK STATE. NOT RESPONSIBLE FOR
DESIGN OR CONSTRUCTION ERRORS
RETAIN STORM WATER RUNOFF provide ivlmdborne debris
PURSUANT TO CHAPTER 236
OF THE TOWN CODE protection for new exterior
glazing on bu='dings as per
NYS Codewo
Mechanical Ventilation PLUMBER CERTIFICATION
system shall be required ON LEAD CONTENT BEFORE
per NYS Energy Code CERTIFICATE OF OCCUPANCY
SOLDER USED IN WATER
SUPPLY SYSTEM CANNOT
EXCEED 2110 OF 1% LEAD.
PLUMBING
ALL PLUMBING WASTE
&WATER LINES NEED
40 S
I
TESTING BEFORE COVERING
k
I
-A
-A".. C
ISSUED FOR PERMIT / CONS'TRUCTION
OCTOBEk 6 , 2025
PROJECT INFORMATION PROJECT TEAM DRAWING LIST
ADDRESS: 40 Madison Street �,� P�MSrR F o
Greenport, NY 11'944 ARCHITECT: A-000 COVER SHEET � z�' '
Armstrong Architecture and Planning A-001 PROJECT INFORMATIO 'N m Y
ZONING: R-40 450 Cemetery Road A-002 PROJECT INFORMATION
East Marion, NY 11939 Tqr
LOT SIZE. 10,57.5 SF 631.338.5325 A-100 FIRST FLOOR PLAN E 0
brina.armstrongl2@gmail.com
A-200 EXISTING ELEVATIONS
A-201 PROPOSED ELEVATIONS
AREA CALCULATIONS: GENERAL CONTRACTOR:
Sarabia Home Improvements A-300 SECTIONS
P.O. Box 74
Proposed Main House Gross Floor Area.: East Marion, NY 11939
631.477.3918
First Floor: 1,442 SF francisco@sarabiahome.com AR.MSTRONG
TOTAL: 1,442 SF ARCHITECTURE &
O
PLANNING
Alterations to
40 MADISON
STREET
Greenport
New York, 11944
COVER SHEET
SCALE: Not To Scale
OCTOBER 6, 2025
ABBREVIATIONS BUILDING DESIGN NOTES FRAMING NOTES
& AND FIN FINISH R RISER 1. ALL ASPECTS OF THE DESIGN AND CONSTRUCTION OF STRUCTURES HALL CONFORM TO ALL LOCAL AND STATE CODES(SEE 1. ALL FRAMING LUMBER SHALL BE GRADE STAMPED DOUGLAS FIR-LARCH STRUCTURAL GRADE NO.2 FOR ALL JOIST CONNECTIONS.HANDLING,STORAGE,AND ERECTION OF ALL COMPONENTS SHALL BE
L ANGLE FLR FLOOR (R) REMOVE RESIDENTIAL CODE OF NEW YORK STATE)THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY IF ANY OF THE DESIGNS ARE OR BETTER.ALL FRAMING SHALL BE NAILED IN ACCORDANCE WITH LOCAL AND STATE CODES(SEE AS PER MANUFACTURER'S SPECIFICATIONS.
@ AT FO FAKE OF RAD RADIUS NOT WITHIN THE CODES OF THE STATE AND LOCAL AUTHORITIES. ATTACHED NAILING SCHEDULE)
4 CENTERLINE FRPF FIREPROOF RD ROOF DRAIN 12. ALL JOISTS SHALL HAVE 1 1/2"BEARING MINIMUM ON WOOD AND 3"MINIMUM ON CONCRETE OR
0 DIAMETER FT FOOT OR FEET REFG REFRIGERATOR 2• ALL HABITABLE ROOMS SHALL HAVE A CEILING HEIGHT OF NOT LESS THAN T-6",AND HALLWAYS,CORRIDORS, 2. ALL WALL SHEATHING SHALL BE APA RATED,EXPOSURE 1. 1/2",5/8",3/4"THICK(SEE DRAWINGS FOR STEEL(SEE MANUFACTURER'S SPEC'S FOR ENGINEERED LUMBER.
FTG FOIOTING REINF REINFORCED BATHROOMS,TOILET ROOMS,AND LAUNDRY ROOMS SHALL HAVE A CEILING HEIGHT OF NOT LESS THAN T-0".BASEMENTS SPECIFICATION).SHEATHING SHALL BE NAILED TO FRAMING IN ACCORDANCE WITH LOCAL AND
AN ADJUSTABLE REQ REQUIRED SHALL HAVE A MINIMUM CEILING HEIGHT OF T-0" (SEE R305 OF NYS RESIDENTIAL CODE FOR MORE DETAILS) STATE CODES(SEE ATTACHED NAILING SCHEDULE). 13 .ALL EXTERIOR WALLS SHALL BE 2X6 NOMINAL THICKNESS DOUGLAS FIR-LARCH NO.2 OR BETTER 161,
AFF ABOVE FINISH FLOOR GA GAUGE RM ROOM O.C.MIN.INTERIOR WALLS SHALL BE 2"X 4"NOMINAL THICKNESS MINIMUM,SEE DRAWINGS FOR
AMSL ABOVE MEAN SEA LEVEL GALV GALVANIZED RO ROUGH OPENING 3. BASEMENTS WITH HABITABLE SPACE AND EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPENABLE EMERGENCY 3. ALL SUBFLOORING SHALL BE APA RATED STUDD-I-FLOOR,EXPOSURE 1,T&G 3/4"THICKNESS.ALL SIZES.
APPROX APPROXIMATE GL GLASS RR ROOF RAFTER ESCAPE AND RESCUE OPENING. OPENINGS SHALL HAVE A SILL HEIGHT OF NOT MORE THAN 44"ABOVE THE FINISH FLOOR. EDGES OF PLYWOOD TO BE SET ON SOLID BLOCKING.GLUE ALL SUB-FLOOR TO JOISTS USING
ARCH. ARCHITECTURAL GLB GL,U-LAM BEAM MINIMUM OPENING AREA SHALL BE 5.0 SQUARE FEET AT ALL GROUND FLOOR OPEININGS AND 5.7 SQUARE FEET AT ALL ADHESIVE FOR THIS PURPOSE.ALL SUB-FLOOR TO BE NAILED IN ACCORDANCE WITH LOCAL AND 13. ALL WOOD FRAME WALLS SHALL HAVE A DOUBLE TOP PLATE(OVERLAPPING CORNERS)AND SINGLE
AVG AVERAGE GND GROUND SALV SALVAGE OTHER OPENINGS. MINIMUM OPENING WIDTH(20"),MINIMUM OPENING HEIGHT(24"). (SEE R310 OF NYS RESIDENTIAL CODE STATE BUILDING CODES(SEE ATTACHED NAILING SCHEDULE). SOLE PLATE(MIN.)THE SAME LUMBER DIMENSION AS THE WALL.WALL BLOCKING SHALL BE INSTALLED
GR GRADE SCHED SCHEDULE FOR MORE DETAILS) OF THE SAME DIMENSION LUMI3ER AT MID SPAN ON WALLS UNDER IY AND IN 1/3 INTERVALS IN
BD BOARD GWB GYISUM WALL BOARD SECT SECTION 4. DOUBLE JOISTS SHALL BE SET UNDER ALL PARALLEL PARTITIONS. TALLER WALLS.
BLDG BUILDING GYP GYPSUM SHR SHOWER 4. WINDOW WELLS SHALL BE DESIGNED FOR BASEMENTS WITH HABITAILE SPACE. THE MINIMUM AREA OF THE WINDOW
BLK BLOCK SHT SHEET WELL SHALL BE 9.0 SQUARE FEET WITH A MINIMUM WIDTH AND HORIZONTAL PROJECTION OF 36". WINDOW WELLS WITH 5. DOUBLE JOISTS OR STRUCTURAL BEAM SHALL TRIM ALL STAIR,CHIMNEY,AND SKYLIGHT OPENINGS. 14. STUDS MAY BE DRILLED AN NOTCHED IN CONFORMANCE WITH R602.6 OF THE NYS RESIDENTIAL
BM BEAM HB HOSE BIB SHTHG SHEATHING A DEPTH GREATER THAN 44"SHALL HAVE A PERMANT LADDER.LADDER SHALL HAVE A INSIDE WIDTH OF AT LEAST 12", SEE FRAMING PLANS FOR MORE DETAILS. CODE.
BO BY OWNER HDR HEADER SIM SIMILAR SHALL PROJECT 3"FORM THE WALL,AND BE SPACED MAXIMUM 18"APART VERTICALLY.(SEE SECTION R310 OF THE NYS
BOT BOTTOM HDWD HARDWOOD SED SEE ELECTRICAL DRAWINGS RESIDENTIAL CODE FOR MORE DETAILS) 6. JOISTS SHALL BE SUPPORTED LATERALLY AT ENDS BY FULL-DEPTH SOLID BLOCKING NOT LESS THAN 2" 15. ALL HEADERS SHALL BE AS SPECIFIED ON PLANS AND NAILED IN ACCORDANCE WITH THE NYS
B'SPLASH BACKSPLASH HDWE HARDWARE SLR SEALER NOMINAL THICKNESS;OR BY ATTACHMENT TO A HEADER BAND JOIST,OR RIM JOIST,OR TO AN RESIDENTIAL CODE AND WFCM,IF THERE IS ANY DISCREPANCY OR IF A SPECIFICATION IS NOT
HGT HEIGHT SPEC SPECIFICATION 5. ALL HABITABLE ROOMS SHALL BE PROVIDED WITH AN AGGREGATE GLAZING AREA OF NOT LESS THAN 8 PERCENT OF THE ADJOINING STUD;OR SHALL BE OTHERWISE PROVIDED WITH LATERAL SUPPORT TO PREVENT PRESENT,CONTACT THE ARCHITECT OR REFER TO TABLE R502.5 OF THE NYS RESIDENTIAL CODE.
CAB CABINET HORIZ HORIZONTAL SS STAINLESS STEEL FLOOR AREA OF SUCH ROOM.THE MINIMUM OPENABLE AREA TO THE OUTDOORS SHALL BE 4 PERCENT OF THE FLOOR ROTATION.
CB CATCH BASIN HR HOUR SSD SEE STRUCTURAL DRAWINGS AREA BEING VENTILATED(SEE R303 OF NYS RESIDENTIAL CODE FOR EXCEPTIONS)EVERY HABITABLE SPACE SHALL BE 16. ROOF BLOCKING SHALL BE SET TO ALLOW 2"AIR SPACE AT THE TOP OF THE RAFTER FOR VENTING.
CEM CEMENT STD STANDARD PROVIDED WITH HEATING CAPABLE OF MAINTAINING A MINIMUM ROOM TEMPERATURE OF 68 DEGREES FARANHEIT,3 7. ALL JOIST TO BE BRIDGED WITH EITHER SOLID BLOCKING,DIAGONAL BRIDGING,OR A CONTINUOUS
CER CERAMIC INSUL INfSULATION STL STEEL FEET ABOVE THE FLOOR AND 2 FEET FROM EXTERIOR WALLS(SEE SECTION R303 OF THE NYS RESIDENTIAL CODE FOR V X 3"STRIP NAILED ACROSS THE BOTTOM OF THE JOISTS PERPENDICULAR TO THE JOISTS AT 17. ALL CEILING JOISTS SHALL LAP A MINIMUM OF 3"AT SPLICE CONDITIONS OVER BEARING WALLS.
CJ CEILING JOIST INT INfTERIOR STOR STORAGE MORE DETAILS) INTERVALS NOT TO EXCEED 8 FEET.
CLG CEILING STRUC STRUCTURAL 18. THE ENDS OF EACH RAFTER OR CEILING JOIST SHALL HAVE NOT LESS THAN 1 1/2"OF BEARING ON
CLKG CAULKING JT JOIINT SUSP SUSPENDED 6. THERE SHALL BE ONE HABITABLE ROOM WITH A MINIMUM FLOOR AREA OF NOT LESS THAN 120 SQUARE FEET.ALL OTHER 8. BEAMS SHALL BE NOTCHED AND DRILLED IN ACCORDANCE WITH R502.8 OF THE NYS RESIDENTIAL WOOD OR METAL AND NOT LLSS THAN 3"ON CONCRETE OR MASONRY.
CLO CLOSET SYM SYMMETRICAL HABITABLE ROOMS SHALL HAVE AN AREA OF NOT LESS THAN 70 SQUARE FEET,KITCHENS SHALL HAVE AN AREA OF NOT CODE OR MANUFACTURERS SPECIFICATIONS FOR ENGINEERED WOOD PRODUCTS.
CLR CLEAR KIT KITCHEN LESS THAN 50 SQUARE FEET.HABITABLE SPACES SHALL NOT BE LESS THAN TIN ANY HORIZONTAL DIMENSION (EXCEPTION 19. ALL ROOF SHEATHING ON ASPHALT ROOFS SHALL BE 1/2"THICK STRUCTURAL PANELS APA RATED,
CMU CONCRETE MASONRY TB TOWEL BAR KITCHEN). (SEE R304 OF NYS RESIDENTIAL CODE FOR MORE DETAILS) 9. DRAFTSTOPPING SHALL BE REQUIRED WHEN THERE IS USABLE FLOOR SPACE BOTH ABOVE AND NAILED IN ACCORDANCE WITH THE NYS RESIDENTIAL CODE(SEE ATTACHED NAILING SCHEDULE).
UNIT LAM LAMINATE TELE TELEPHONE BELOW THE CONCEALED SPACE OF A FLOOR/CEILING ASSEMBLY,DRAFTSTOPS SHALL BE INSTALLED SO
CNTR COUNTER LAV LAVATORY T&G TONGUE&GROOVE 7. ALL DESIGNS SHALL BE IN CONFORMANCE WITH THE ENERGY CONSERVATION CODE OF NYS AND THE NYS RESIDENTIAL THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED 1000 SQUARE FEET(SEE R502.12 OF NYS 20. ALL WOOD ROOF SHALL BE COMPLETELY SHEATHED WITH 1/2"THICK STRUCTURAL PANELS APA
COL COLUMN LB POUND THK THICK CODE(SEE CHAPTER 11 THE FOLLOWING GLAZING AND INSULATION VALUES SHALL BE USED ALONG WITH THE ENERGY RESIDENTIAL CODE FOR MORE DETAILS). RATED,NAILED IN ACCORDANCE WITH THE NYS RESIDENTIAL CODE(SEE ATTACHED NAILING
COMP COMPOSITION LN LINOLEUM TO TOP OF )' SCHEDULE 5/4 X 3 SPRUCE LATH SHALL BE INSTALLED 16"O.C.PARALLEL AND IN LINE WITH THE
CONC CONCRETE LT LIGHT TV TELEVISION CONSERVATION CALCULATIONS: )• G�
CONC CONSTRUCTION LVL LAMINATED VENEER LUMBER TYP TYPICAL GLAZING U-FACTOR: .40 MAX 10. ALL PRESSURE TREATED MATERIAL SHALL BE PRESERVATIVELY TREATED AND DRIED AFTER ROOF RAFTERS 5/4 X 3 LATH SHALL BE INSTALLED PERPENDICULAR TO THE ROOF RAFTERS SPACED
CONT CONTINUOUS CEILING R-VALUE:R-38(R-30 MAY BE USED AT SLOPED CEILINGS TO ALLOW FOR AIR FLOW) TREATMENT IN ACCORDANCE WITH AWPA C22.SEE DRAWINGS FOR DIMENSIONAL SPECIFICATIONS TO ALLOW AIR FLOW BEHIND THE WOOD SHINGLE ROOF FINISH.
WALL R-VALUE: R-19 AND USES.
CONTR CONTRACTOR MAX MAXIMUM UC UNDER COUNTER FLOOR R-VALUE:R-21 21. ALL FRAMING SHALL BE STRAPPED AS PER THE ATTACHED SCHEDULES WITH STRAPS MANUFACTURED
CPT CARPET MC MEDICINE CABINET UNF UNFINISHED BASEMENT R-VALUE:R-10 11. ALL PRE-ENGINEERED LUMBER SHALL BE GEORGIA PACIFIC WI SERIES JOISTS(WOOD I-BEAMS),LVL BY SIMPSON STRONG TIE OR EQUAL SUBSTITUTIONS SHALL BE SUBMITTED TO THE ARCHITECT FOR
MECH MECHANICAL UON UNLESS OTHERWISE NOTED SLAB PERIMETER:R-9(DEPTH OF 4') PRODUCTS,AND ANTHONY POWERBEAM PRODUCTS.ALL JOISTS,GIRDERS,AND HEADERS SHALL APPROVAL PRIOR TO INSTALLATION.
DBL DOUBLE MEMB MEMBRANE CRAWL SPACE:R-19 HAVE BEARING STIFFENERS INSTALLED AS PER MANUFACTURERS RECOMMENDATIONS.WEB
DEMO DEMOLITION MFR MANUFACTURER VERT VERTICAL STIFFENERS SHALL BE REQUIRED AT ALL LOAD AND BEARING POINTS. DOUBLE 1 3/4"LVL'S SHALL BE
DEPT DEPARTMENT MIN MINIMUM VEST VESTIBULE 8. THE FOLLOWING CRITERIA WAS USED IN THE BUILDING DESIGN: INSTALLED AT ALL STAIR,CHIMNEY,AND OTHER FLOOR OPENINGS.SEE MANUFACTURER'S NOTES
DET DETAIL MIR MIRROR VIF VERIFY IN FIELD
DIA DIAMETER MISC MISCELLANEOUS WIND ZONE 130 MPH(3 SECOND GUSTS)
DIM DIMENSION MTD MOUNTED W/ WITH EXPOSURE B
DN DOWN MTL METAL WC WATER CLOSET GROUND SNOW LOAD 20 PSF
DR DOOR MUL MULLION WD WOOD LIVE LOADS OF 30 PSF SLEEPING AREAS,40 PSF LIVING AREAS ENERGY NOTES
DS DOWNSPOUT W/0 WITHOUT DEAD LOAD 15 PSF
DTL DETAIL (N) NEW WP WATERPROOF
DW DISHWASHER NIC NOT IN CONTRACT WRC WESTERN RED CEDAR 9. ALL DESIGNS REPRESENTED ARE PRESCRIPTIVE.IF ENGINEEREll DESIGNS ARE PRESENT,CALCULATIONS WILL BE SUPPLIED.
DWG DRAWING NOM NOOMINAL WSCT WAINSCOT
DWR DRAWER NTS N(OT TO SCALE WT WEIGHT 10. WIND BORNE DEBRIS PROTECTION(PER R301.2.1.2 OF THE NYS RESIDENTIAL CODE).}!"THICK WOOD STRUCTURAL PANELS
SHALL BE PROVIDED FOR ALL GLAZED OPENINGS.STRUCTURAL PANELS SHALL BE FASTENED TO THE FRAMING IN THE TABLE R301.2(1)
EXTG/(E) EXISTING OA O'VERALL EVENT OF HURRICANE FORCE WINDS TO PROTECT FROM WIND BORNE DEBRIS.PANELS SHALL BE FASTENED WITH 2%"#6
EA EACH OC OIN CENTER WOOD SCREWS @ 16"O.C.FOR PANELS LESS THAN 4",12"O.C.FOR PANELS GREATER THAN 4'AND LESS THAN 6',9"O.C.FOR CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
EJ EXPANSION JOINT OCC OCCUPANCY PANELS GREATER THAN C AND LESS THAN 8'(SEE R301.2.1.2 FOR MORE DETAILS).
ELEC ELECTRICAL OFCI OWNER FURNISHED,
ELEV ELEVATION CONTRACTOR,INSTALLED 11. ALL FRAMING SHALL BE NAILED AND FASTENED IN ACCORDANCEE WITH THE NYS RESIDENTIAL CODE ANDTHE WFCM.SEE WIND SUBJECT TO DAMAGE FROM ICE SHIELD
ENCL ENCLOSURE OFOI OWNER FURNISHED, ATTACHED NAILING SCHEDULE AND FASTENER DIAGRAMS FOR DETAILS.THE ARCHITECT SHALL BE NOTIFIED GROUND SIESMIC WINTER UNDERLA-
EP ELECTRICAL PANEL OWNER INSTALLED IMMEDIATELY IF ANY OF THE SPECIFICATIONS DO NOT MEET CODE REQUIREMENTS OR IF ADDITIONAL SPECIFICATIONS SNOW DESIGN FROST DESIGN YMENT FLOOD
E EQUAL OFF OFFICE ARE REQUIRED. LOAD SPEED MPH CATEGORY LINE TEMP HAZARDS
Q Q (MPH) WEATHERING TERMITE DECAY REQUIRED
- E PT E UIPMENT OPNG OPPENING
EQQP EXPANSION OPP OPPOSITE 12. ALL EXTERIOR FINISHES SHALL BE IN CONFORMANCE WITH THE NYS RESIDENTIAL CODE. DEPTH
EXT EXTERIOR 20 PSF 130 MPH + B SEVERE 3611 MODERATE SLIGHT TO 11 YES
PC POURED CONCRETE 13. ALL ROOF OVERHANGS SHALL RELIEVE ONE LAYER OF ICE AND WATER FROM THE OUTSIDE EDGE OF THE OVERHANG TO
FA FIRE ALARM PERP PFERPENDICULAR A MINIMUM OF 24"INSIDE THE OUTSIDE WALL.ALL UNDERLAYMENT SHALL BE NAILED DOWN WITH CORROSION DECAY MODERATE
FBR BD FIBER BOARD PL PRATE RESISTANT FASTENERS IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS.
FBRGL FIBERGLASS PLAS PILASTER
FD FLOOR DRAIN PLYWD RLYWOOD 14. ALL FLASHING SHALL BE SPECIFIED BY THE ARCHITECT AND/OR CONFORM TO NYS RESIDENTIAL CODE(SEE SECTION R905 1. ALL CONSTRUCTION SHALL COMPLY WITH THE 2015 INTERNATIONAL ENERGY CONSERVATION CONSTRUCTION
FDN FOUNDATION PT PRESSURE TREATED FOR ROOF COVERING). CODE.THE AUTHORITY HAVING JURISDICTION SHALL BE PERMITTED TO DETERMINE AN ENERGY EFFICIENCY
PTD PAINTED PROGRAM TO EXCEED THE ENERGY EFFICIENCY REQUIRED BY THIS CODE.
15. ALL MECHANICAL SYSTEMS SHALL CONFORM TO THE NYS RESIDENTIAL CODE,THE MECHANICAL CODE OF NYS AND THE E ARC
FUEL GAS CODE OF NYS. 2. A PERMANENT CERTIFICATE SHALL BE COMPLETED BY THE BUILDER AND POSTED ON A WALL IN A SPACE WHERE
THE FURNACE IS LOCATED.CERTIFICATE SHALL COMPLY WITH RC N1101.14. "� co
16. PLEASE REFER TO H.E.R.S.REPORT FOR MECHANICAL AND INSULATION SPECIFICATIONS. Af
3. ATTIC OR CRAWL SPACE ACCESS SHALL BE WEATHERSTRIPPED AND INSULATED TO A LEVEL EQUIVALENT TO THE UJ
INSULATION ON THE SURROUNDING SURFACE. Q s - -� �, co
1. Y
4. INSTALLATION-THE COMPONENTS OF THE BUILDING THERMAL ENVELOPE SHALL BE INSTALLED IN ACCORDANCE ' ,`
/�
WITH THE CRITERIA LISTED IN TABLE 402.4.1.1.WHERE REQUIRED BY THE CODE OFFICIAL,AN APPROVED THIRD * - go
SANITARY RISER DIAGRAM CONCRETE/MASONRY NOTES PARTY SHALL INSPECT ALL COMPONENTS AND VERIFY COMPLIANCE.
5. TESTING-BUILDING OR DWELLING UNIT SHALL BE TESTED AND VERIFIED HAVING LESS THAN OR EQUAL TO 3 -nh
nrun:,6u,1 •`'^w,. Attic 1,
ACH501N CZ 4A,5,6A.TESTING SHALL BE CONDUCTED BY AN APPROVED THIRD PARTY. vltl,riL�unr, ({{
lilt .: 1
1. MASONRY CONSTRUCTION SHALL BE DESIGNED IN ACCORDANCE WITH THE PROVISIONS OF SECTION R606 OF THE NYS 6. DUCTS-SUPPLY AND RETURN DUCTS IN ATTICS SHALL BE INSULATED TO A MINIMUM OF R-8 @ 3"OR GREATER IN Aw ":r Al INN `rat�Sttr'tUe
RESIDENTIAL CODE OR IN ACCORDANCE WITH THE PROVISIONS OF ACI 530/ASCE 5/TMS402. DIAMETER,AND R-6 @ DUCTS LESS THAN 3"IN DIAMETER. «
2. ALL CONCRETE SHAL BE POURED IN AMBIENT TEMPERATURES OF 40+DEGREE F.IF POURING IN COLDER WEATHER,THE 7. DUCT SEALING-DUCTS,AIR HANDLERS AND FILLER BOXES SHALL BE SEALED. SOFFIT AI7�1� EAT C
NEW EXTG., EXTG. EXTG. CONCRETE MUST BE PROTECTED FROM FREEZING FOR A PERIOD OF 14 DAYS(ADD MIXTURES CONTAINING CHLORIDES SEAL
BATHROOM LAUNDDRY KITCHEN BATHROOM SHALL BE PROHIBITED). 8. DUCT TESTING-DUCTS SHALL BE PRESSURE TESTED TO DETERMINE AIR LEAKAGE BY AN APPROVED THIRD PARTY.
3. ALL FOOTINGS AND STRUCTURAL SLABS SHALL BE POURED ON UNDISTURBED VIRGIN SOIL,HAVING A MINIMUM BEARING 9. BUILDING CAVITIES SHALL NOT BE USED AS DUCTS OR PLENUMS.
CAPACITY OF TWO TONS PER SQUARE FOOT. ARMSTRONG
10. MECHANICAL SYSTEM PIPING INSULATION CARRYING FLUIDS> 105 F DEGREES OR<55 F DEGREES SHALL BE "r
TUE LAV WASI-1 SK TUB 4. ALL FOUNDATION WALLS SHALL HAVE A MINIMUM THICKNESS OF 8",ALL FOOTINGS SHALL HAVE A MINIMUM DIMENSION INSULATED WITH R-3 MINIMUM.
SH WC DW LAV WC SH OF 8"DEEP AND 16"WIDE.SEE PLANS FOR ACTUAL FOUNDATION WALL THICKNESS AND FOOTING SIZES. ..,- ARCHITECTURE &
, w-
11. MECHANICAL VENTILATION-SHALL MEET THE REQUIREMENTS OF THE IRCAMC.
FIRST FLR
5. ALL CONCRETE SHALL BE 3000PSI AT 28 DAYS. - PLANNING
IN G
TO EXTG. 12. EQUIPMENT SIZING-PER ACCA MANUAL S,BASED ON LOADS CALCULATED PER ACCA MANUAL J AS PROVIDED BY A
SEPTIC THIRD PARTY HERS RATER.
6. THE CONCRETE CONTRACTOR SHALL PROVIDE ANCHOR BOLTS,INSERTS,SLEEVES,ETC.AS REQUIRED BY OTHER
SYSTEM Q
TRADES.ANCHOR BOLTS SHALL BE SET PER NYS RESIDENTIAL CODE. SEE ATTACHED STRAPPING SCHEDULE FOR SPACING d
EXTG. CO AND SIZE. 13. LIGHTING-A MINIMUM OF 75% OF PERMANENTLY INSTALLED FIXTURES MUST HAVE HIGH-EFFICACY LAMPS. j �„ k a,
EXTG. HOUSE TRAP 7. ALL REINFORCEMENT SHALL BE TIED IN PLACE BEFORE CONCRETE IS POURED. AL REINFORCEMENT AND FABRIC FOR 14. ALL HVAC,PLUMBING&ELECTRICAL SYSTEMS SHALL MEET THE IRC CHAPTER 11 ENERGY EFFICIENCY, ga ` Alterations to
INTERNATIONAL MECHANICAL CODE,INTERNATIONAL ENERGY CONSERVATION CODE.IT SHALL BE THE I`
CONCRETE POURED ON GROUND SHALL BE SUPPORTED ON PRECAST BRICKS OR APPROVED CHAIRS. � 4
RESONSIBILITY OF THE GENERAL CONTRACTOR TO SUBMIT IN DETAIL THE DESIGN,CALCULATIONS,DRAWINGS,
8. LEGS OF REBAR ACCESSORIES SHALL BE PLASTIC TIPPED. ALL SNAP TIES AND WALL PENETRATIONS SHALL BE CUT BACK WRITTEN STATEMENT OF THE MECHANICAL,AIR CONDITIONING,VENTILATION,HEATING SYSTEMS(NEW,
40 MADISON
AND GROUTED TO PRECLUDE ANY CORROSION. EXISTING,OR UPGRADED)STAMPED BY A PROFESSIONAL ENGINEER IF REQUIRED BY THE OWNER OR BUILDING
DEPARTMENT. 1 _ '
9. ALL REINFORCEMENT BARS SHALL BE CONTINUOUS EXCEPT AS NOTED,LAPPED PER AC1318,CLASS"C",WITH 40 STREET
,.. ..
DIAMETERS MINIMUM,BENT AROUND CORNERS AND HOOKED AT NON-CONTINUOUS ENDS. FOR FRAMED SLABS,LAP 15. ADDITIONS,ALTERATIONS,OR RENOVATION;SHALL COMPLY WITH IECC 2015.UNALTERED PORTIONS OF THE ° -_ ,
TOP BARS AT MID SPAN BETWEEN SUPPORTS AND BOTTOM BARS AT SUPPORTS,REVERSE FOR FOUNDATION MATS. EXISTING BUILDING IS NOT REQUIRED BY THE OWNER OR BUILDING DEPARTMENT.
STAGGER SPLICES AND OFFSET SPLICES OF BARS AT OPPOSITE ENDS. 16. MINIMUM ONE PROGRAMMABLE THERMOSTATS SHALL BE PROVIDED FOR EACH SEPARATE HEATING AND AIR SEALED WALL Greenp ort
COOLING SYSTEM IN ACCORDANCE WITH SECTION N1103 CONTROL SYSTEMS.
10. ALL SLAB ON GRADE THICKNESSES SHOWN ARE MINIMUM THICKNESSES TO BE USED,INCREASE AS REQUIRED FOR 17. ALL EXTERIOR WALL/FLOOR/CEILING JOISTS SHALL BE AIR SEALED AND INSULATED IN ACCORDANCE WITH TABLE
DRAINAGE PITCH. R402.4.1.1.APPLY A FRESH BEAD OF CAULK TO THE TOP AND BOTTOM PLATE IMMEDIATELY PRIOR TO INSTALLING New York, 11944
INTERIOR GYPSYM WALL BOARD.
11. SLABS ON GRADE SHALL BE PLACED IN STRIPS AND SHALL THEN BE SAW-CUT OR TOOLED TO PROVIDE CONTROL JOINTS
APPROXIMATELY 20'O.C.,CONSTRUCTION JOINTS SHALL BE KEYED.
12. EXCEPT AS NOTED,ALL OUR STOPS SHALL BE TREATED AS CONSTRUCTION JOINTS AND SHALL HAVE KEYS AND INSULATION SPECIFICATIONS:
FLAT CEILINGS:R-38 BATTtm
CONTINUOUS REBAR. WALL SECTIONS SHALL BE PLACED ALTERNATIVELY OR WITH A MINIMUM OF 24 HOURS BETWEEN .. .w �«
J VAULTED CEILINGS:R-30 BATT '` ' PRO ECT
ADJACENT POURS. ?"' -A� - T
FLOORS ABOVE UNCONDITIONED SPACE:R-38 BATT J
ABOVE GRADE EXTERIOR WALLS:R-21 BATT IN 2X6 WOOD STUDS l
13. FOR CONCRETE WALLS,VERTICAL CONSTRUCTION JOINTS SHALL BE LOCATED AT A MAXIMUM SPACING OF 40 AT LEAST 4 T T
ABOVE GRADE GARAGE WALLS:R-21 BATT IN 2X6 WOOD STUDS j
AWAY FROM ANY SUPPORTING OR INTERSECTING WALL OR BUTTRESS,OR ANY WALL OPENING. - �' INFORMATION
BASEMENT WALLS:R-15 BATT IN 2X4 WOOD STUDS 8,;, "A�eke , ... !
WINDOWS - GLAZED OPENINGS 14. HORIZONTAL CONSTRUCTION JOINTS WILL NOT BE PERMITTED EXCEPT WHERE NOTED ON PLANS OR SHOWN AN FOUNDATION WALLS:8",R-13 IN 2X4
ACCEPTED ON SHOP DRAWINGS. - . Not TO Scale
' r OCTOBER 6 2025
15. CONCRETE WALLS,DECKS,AND SLABS REQUIRING WATERPROOFING SHALL CONFORM TO AC1515. 1R-79 SPECIFICATIONS, MECHANICAL SPECIFICATIONS: r �•a ,•s:�e. r" ; .„I'"`:. ; I
1. FOR NEW CONSTRUCTION,EXTERIOR WINDOWS MUST'BE PROTECTED VIA:GLAZING MEETING THE LARGEST MISSILE TEST _
>95%AFUE GAS BOILLR
CHAPTER 3 FOR CONCRETE SURFACE QUALITY AND FINISHES. CURING COMPOUNDS,RELEASE COATINGS OR ADD
Q 715 SEER EQUIPMENT ACE "
CERTIFICATION OF ZONE 1 ASTM E-1886-97 AND ASTM 996i-99 OR STRUCTURAL SHUTTERS WITH HARDWARE PROVIDED. MIXTURES THAT INTERFERE WITH THE ADHESION OF THE BARRIER MATERIAL SHALL NOT BE USED.LIQUID APPLIED Q
2. NEW STRUCTURES LOCATED WITHIN ONE MILE OF MEAN4 HIGH WATER MUST HAVE GLAZING CONFORMING TO WIND ZONE 1. BARRIERS SHALL NOT COVER,HIDE,OR LEVEL SURFACE IRREGULARITIES. MECHANICAL VENTILATION >110 CFM
3. ALL PROTECTION PANELS TO BE IN COMPLIANCE WITH LARGE MISSILE TEST OF ASTM E 1996 AND ASTM 1886,AS NOTED IN NYS RESIDENTIAL ONE ENERGY STAR BATH FAN WITH AN ELECTRONIC PROGRAMMABLE TIME
CODE. 16. MASONRY OVER OPENINGS SHALL BE SUPPORTED BY STEEL LINTELS,REINFORCED CONCRETE OR MASONRY LINTELS,OR OTHER SPECIFICATIONS:
MASONRY ARCHES DESIGNED TO ACCEPT LOAD IMPOSED. WINDOWS:U<0.28,SHGC<0.28
17. THE BOTTOM OF ALL FOOTINGS SHALL BE A MINIMUM OF 36"BELOW FINISH GRADE. >100°o HIGH EFFICIENCY LIGHTING(CFL's OR LEDs) } -001
THESE PLANS MEET 2018 :ICC RESIDENTIAL CODE AS <3 AIR CHANGES PER HOUR DUCT SEALING REQUIRMENTS
18. ALL CHIMNEYS AND FIREPLACES SHALL BE DESIGNED IN ACCORDANCE WITH CHAPTER 10 OF THE NYS RESIDENTIAL CODE. ALL APPLIANCES MUST BE ENERGY STAR CERTIFIED
ADOPTED BY THE NYS 2,020 RESIDENTIAL CODE
/ U
n
,
,
`
~
~
�
LEGEND:
EXISTING BUILDING
NEW WORK
WINDOW SCHEDULE
WINDOW NO. MFTR. PRODUCT# OPERATION FINISH ANDERSEN PROVIDED TRIM EGRESS F SCREENS NOTES
J ——— EXISTING REMOVED ALTERED
101 (2) WDH2656 DOUBLE-HUNG WHITE DRIP CAP,3-1/2"FLAT CASING,SILL NOSE J /
102 WDH2656 DOUBLE-HUNG WHITE DECORATIVE DRIP CAP,3-1/2"FLAT CASING,SILL NOSE J J
103 WDH2656 DOUBLE-HUNG WHITE DECORATIVE DRIP CAP,3-1/2"FLAT CASING,SILL NOSE J J
104 WDH2656 DOUBLE—HUNG WHITE DRIP CAP,3-1/2"FLAT CASING,SILL NOSE J J
105 WDH26310 DOUBLE—HUNG WHITE DRIP CAI',3-1/2"FLAT CASING,SILL NOSE J ELECTRICAL KEY
106 ANDERSEN 400 (2) WDH2656 DOUBLE—HUNG WHITE DRIP CAP,3-1/2"FLAT CASING,SILL NOSE J / ALL WINDOWS IN EXTG.
SERIES WALLS,EXCEPT
107 WDH3432 DOUBLE—HUNG WHITE DRIP CAP,3-1/2"FLAT CASING,SILL NOSE / WINDOW 112,TO USE EXTG. ADJ. DOWN LIGHT
V HEADERS,HEAD HEIGHTS
108 (3) WDH2656 DOUBLE—HUNG WHITE DECORATIVE DRIP CAP,3-1/2"FLAT CASING,SILL NOSE J / TO MATCH FRONT DOOR ® FIXED DOWN LIGHT
v THROUGHOUT.
109 WDH2446 DOUBLE—HUNG WHITE DRIP CAP,3-1/2"FLAT CASING,SILL NOSE J FIXED DOWN LIGHT WET LOCATION
110 WDH2446 DOUBLE—HUNG WHITE DRIP CAP,3-1/2"FLAT CASING,SILL NOSE J
]11 WDH2446 DOUBLE—HUNG WHITE DRIP CAP,3-1/2"FLAT CASING,SILL NOSE J SURFACE MOUNT
112 (3) WDH2656 DOUBLE—HUNG WHITE 3-1/2"FLAT CASING,SILL NOSE J J
�0 CLOSET LIGHT
DUPLEX OUTLET
HALF-SWITCHED DUPLEX OUTET
TV T TV LOCATION
ISWITCH -ALL SWITCHES TO HAVE DIMMERS
JAI JAMB ACTIVATED SWITCH
OC' rC � rC
P05T POST POST POST
2
26'-Oz" VIF 7'-1 4" 7'-1 4" 7'-1 4° N
FRONT PORCH r-————-�
II IIO
3 3
8'-54" 11'-44"
IOI
GARAGE CONVERSION TO PRIMARY SUITE
- NEW WOOD FLOORING INSTALLED ON I Iz ( I
NEW SUB-FLOOR AND FR.,A41NG. g
FINISHED FLOOR ELEVATION OF 1 „ 2 1 I „ 771
CONVERSION TO ALIGN W1 FIN15H FLOOR 2-3 I O-12 VIF 2'-3" 5-82 4-1 14 - -
ELEVATION OF EXTG. HOP✓AE.
EXTERIOR WALL FRAMING FO REMAIN;
NEW WINDOWS IN NEW OPENINGS I I I ( CL.
NEW INSULATION AT FLC, 5, WALLS, Iog I Io III
AND ROOF.
- NEW HVAC UNIT LOCATED ABOVE BATH 2 I
TO SERVICE NEW PRIMARY SUITE
NEW INTERIOR DOORS(4) TOTAL -- BEDROOM I
PRE-FINISHED WOOD FLOORING IN HALL - LIVING ROOM
(105), CLOSET, *PRIMARY BED(10( 14'-73" VIF _I, /O'-9'3" O IOI Io6 ��FtE� RC'
- BATH 2(1 1 O) TO HAVE TILE FLOORING, 4 �° 3'-1 13, `� 3° - NEW WINDOWS IN PR S riQ
AND TILE TO WAINSCOT 11EIGHT ON p 2-7„ 4 - NEW WINDOW IN I EXTG. OPENINGS P
WALLS N mId- 1`71 ENLARGED OPENING CL. I - PATCH AND REPAIR
- GWB FINISH ON WALLS AND CEILINGS �'J W - PATCH AND REPAIR e►.
U.O.N. W c��d WALLS AS NEEDED CASING AS NEEDED sas
- PRIMARY BEDROOM TO HAVE GABLED ILn - Ioz - * �,
CEILING; EXTG. COLLAR TIES TO HAVE ® TO X I J. 0 O�
DECORATIVE, PTO. WD. WRAP � ,9 D4069
- INTEGRATE BATH EXHAUST WITH RETURN
GRILLE IN BATH 2 c�l� Io8 rr� I�
_ — OF NE
Lj
N
PRIMARY BEDROOM _ _ _ _ _ — CL.
3,, _ m 3 _ HALL - - - - - -
It+.s X 13 r 31JJ"ice � 44 I� 44 T A I O BA E11 E T I Ios
W r-IN o � � �' � - NO NEW WORK P'n
� 74
PurP°�-S f cJ
T� - - - - �F - - ARMSTRONG
cD OFFICE
KIITCHEN DINING ROOM CL. R
Io6 ARCHITECTUE &
103 Ioz ° - NEW WINDOWS IN
HALL J - NEW WJINDOW IN EXTG. - NEW WINDOW IN EXTG. 0 EXTG. OPENfNGSLJ+
PLANNING
I —IN OPEAWNG OPENING - PATCH AND REPAIR
Io8 I J - PATCHIAND REPAIR - PATCH AND REPAIR CASING AS NEEDED
—� — CA51WG AS NEEDED CASING AS NEEDED
PANTRY L — I ow
_ � Alterations to
DEMO WALLS; NEW WALLS PER PLAN 4 O MADISON
- PATCH AND REPAIR
FLOOR WHERE REQ'D BATH I
- NEW CABS. C70P io Io6 Ios 107 Io4
NEW SURROUND FOR STREET EXTG. W/D I I I _ NEW WINDOW IN EXTG.
- EXTG. EXT. DOOR TO OPENING
REMAIN - PATCH AND REPAIR
CASING AS NEEDED Greenport
New York, 11944
FIRST FLOOR PLAN
SCALE: 4" "= 1'-0
OCTOBER 16, 2025
I Proposed First Floor Plan
Ili
MST c
-- -- - IX
s 40
4 p
4 Existing South Elevation 3 Existing East Elevation
t�200 1/4" = 1'-0" 1/4" = 1'-0"
ARMSTRONG
ARCHITECTURE &
PLANNING
Alterations to
-- 40 MADISON
STREET
Greenport
New York, 11944
- EXISTING ELEVATION
SCALE: ill = 1'-0"
OCTOBER 6, 2025
2 Existing North Elevation z Existing West Elevation
A 2 1/1/4" = 1'-0" 1/4" = 1'-0" A- 100
'I
i
PROVIDE NEW 3-1/2"CA51NG AT EXTG. DOOR
TO MATCH ANDERSEN TRIM
REPLACE EXTG. GARAGE DOOR W/NEW WALL
W/NEW WINDOW
O 0 413
o Tq TE OF
_ o
0 0 0
ARMSTRONG
4 Proposed South Elevation 3 Proposed East Elevation ARCHITECTURE &
A 201 1/4" = 1'-0" t 1/4" = 1'-0"
PLANNING
�— PROVIDE NEW 3-1/2"CASING AT EXTG. DOOR
TO MATCH ANDERSEN TRIM
5x6 VER5ATEC COLUMN WRAP AT PORCH, Alterations to
-- 'yp ALL TRIM TO 8E 40 MADISON
NEW ASPHALT ROOF AT PORCH ------ — — -
PROVIDE 5", 'HARDIE'4 SMOOTH TRIM, TO MATCH EXTG. REPLACED WITH
RAKING FASCIA AT GABLE ENDS IF
POSSIBLE WITH EXTG. ROOF _ 'R a SMOOTH STREET
ROOFING TO REMAIN TRIMIM B BOARDS; TYP.
Greenport
IF GUTTERS NEED TO BE
REPLACED, REPLACE W/ New or 11944
WHITE HALF-ROUND
GUTTERS AND ROUND
REPLACE ALL DOWNSPOUTS
B.O. PORCH BEAM
SOFFITS W/ -- ALIGNS w/B.O. HOU5E
'HARDIE' EAVE
CEDARMILL
SOFFIT PANELS NEW, WHITE ANDERSEN PROPOSED
400-5ERIE5 WINDOWS W/ I I O
O 02 ANDERSEN TRIM O o
ENHANCED TREX I 2
DECKING AT NEW'HARDIE PLANK'LAP SIDING - ELEVATIONS
PORCH AND STEPS; SELECT CEDARMILL, 0
COLOR TBD EXPOSURE, COLOR TBD SCALE:i" = 1'-0"
OCTOBER 6, 2025
z Pf oposed NorthElevation I Proposed West Elevation.
1�Z�I 1/.1" = 1'-0" 1/4" = 1'-0"
A-201
II
�I
2" PLYWOOD
ARCHITECTURAL ASPHALT
33 ROOFING
4
c�
C\l 4 it VENT SPACE yjpwowh
4" VENT SPACE
W/SCREENING B.O. PORCH BEAM TO
V-GROOVE BDS. ALIGN W/ B.O. HOUSE
ON -Lit 8" FIN . BEAM 3" OVERHANG SAVE
12 CyT
Q / . 5
��—NEW PORCH ROOF NEW ARCHITECTURAL ASPHALT ROOF �U
/ WILL NOT HIT EXTG, TO MATCH EXTG. ROOF, OVER (2)
ni r
3 Section Detail @ Porch Beam SOLAR PANELS LAYERS OF 30# FELT, OVER 2"COX PROVIDE NEW * _
INSULATION IN EXTG.
3 it-Off2X8 ROOF FRAMING
_ PLYWOOD ROOF SHEATHING, OVER FRAMING AS REQ'D cP� 40
A 300 —
+9'- O-1/4 „
T.O. LEDGER l
GOOF RgF7ERS @ 6„o +8 3-3/4 „
�x6 GL71dG �OfST� (� 16_O.C. T.O. BEAK
(3) 2X8 PORCH B.O. PORCH BEAM TO ALIGN w/B.O.
ENHANCED TREX
S71-RUCTUF:AL BEAM HOUSE SAVE
�
DECKING 5X5 VERSATEX COLUMN WRAP; TYP.
5-411 ARMSTRONG
" VENT SPACE (3) 2X8 ACO PORCH EXTG. FRAMING; TYP,
4
W/SCREENING BEAM z ARCHITECTURE &
6xi6 ACO STRUCTURAL D
POSTS, w,HEAVY o
GALVANIZED
PLANNING
= i GAILVANIZED POST � i
—IN ANICHORS @POURED ,z
CONCRETE o
FOUNDATION, TYP.Off o�
3 EXTG, FF FFL IN NEW PRIMARY Alterations to
SUITE TO MATCH FFL
ENIH'ING, TREX 40 �D I S O N
DEiCKING, COLOR TBD. IN EXTG. HOME
co +O'- O " +O'- Off
T.O. 1 sT FLOOR FF T.O. 1 sT FLOOR FF STREET
[2:x�ACQ PORCH JOISTS @ I G"0. INSULATE FLOOR
Greenport
CAVITY
New York, 11944
/
/ EXTG. FOUNDATION
14"'0 50NOTUBE _"= z // WALL AND SLAB
—IN PIEK5 UNDER /
co POFRCH COLUMNS m / SECTIONS
/ SCALE. 1" = 1'-0"
/ 4
COMPACTED, OCTOBER 6, 2025
GRANULAR FILL
EXTG. FOUNDATION
WALL
4 Section Detail @ Porch Deck a Porch Section 1 Section @ Primary Bedroom A-300
A 300 3" = 1'-01, A 300 1/2" = 1'-0" A 300 1/2" = 1'-0"
U
tn9� u Ih ldt
0150
a .
i
� IIIltllllll 11 11 111111111111111 I' _
D�sa aBla
aoo,,,Mc C
y