Loading...
HomeMy WebLinkAbout52533-Z hO�apf SOl/ryOlo Town of Southold * * P.O. Box 1179 {o0 53095 Main Rd U ff". Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 47256 Date: 07/30/2026 THIS CERTIFIES that the building SINGLE FAMILY DWELLING-ALTERATION Location of Property: 765 Madison St Greenvort, NY 11944 Sec/Block/Lot: 41.-1-2 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 10/21/2025 Pursuant to which Building Permit No. 52533 and dated: 12/10/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Additions and alterations including a garage converted to a bedroom and a new covered porch to an existing single-family dwelling. The certificate is issued to: Matthew Charters ,Kaitlin Charters Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 52533 6/2/2026 PLUMBERS CERTIFICATION: utho ' ed Si ature i "of sou TOWN OF SOUTHOLD BUILDING DEPARTMENT • SOUTHOLD, NY cournr.�' BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52533 Date: 12/10/2025 Permission is hereby granted to: Matthew Charters 40 Madison St Greenport, NY 11944 To: Construct additions and alterations to an existing single-family dwelling to include garage conversion to a bedroom with HVAC system,window and door replacements and new porch. Office is not to be used as a bedroom. Premises Located at: 765 Madison St, Greenport, NY 11944 SCTM#41.4-2 Pursuant to application dated 10/21/2025 and approved by the Building Inspector. To expire on 12/10/2027. Contractors: Required Inspections: Fees: Single Family Dwelling- Addition&Alteration $484.00 CO Single Family Dwelling-Addition /Alteration $100.00 Total S584.00 --- � F) Building Inspector SO(/l�olo Town Hall Annex Telephone(631)765-1802 54375 Main Road G P.O.Box 1.179 Southold,New York 11971-0959 ��yCOUNTI,�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Matthew Charters Address: 765 Madison St AKA 40 City: Greenport st: NY zip: 11944 Building Permit#: 52533 Section: 41 Block: 1 Lot: 2 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Electrician: Retrofit Electric Inc License No: 60131ME SITE DETAILS Office Use Only Commercial Indoor X Basement X Service X Solar Residential X Outdoor X 1st Floor X Pool Battery Storage As-built Renovation 2nd Floor Hot Tub EV Charger New X Addition Attic Spa Generator Survey Mezzanine Garage Dock INVENTORY Service 1 ph X In-wall Heater Recpt 6 Ceiling Fixtures Smoke Detectors 3 Pump Service 3 ph Hot Water 30A GFCI Recpt 4 Wall Fixtures 2 CO Detectors Heater Main Panel 200A A/C Condenser Single Recpt RecessdFixtures 13 Combo Smoke/CO 3 Transformer Meter Main 200A A/C Blower Range Recpt Ceiling Fan 1 Heat Detectors Salt Gen Transfer Switch Mini Split Dryer Recpt UC Lights Fridge AutoCover ARC 2 Blower Heads Switches 7 Pucks Lights Dishwasher Mini Fridge GFI SepticDisconnect Emrgency Strobe 4'LED Microwave Garbage Disp. ARC/GFI ERV Exit Lights Bath Exhaust 1 Hood Dehumidifier Other Equipment: 200A Panel 30 Circuit/27 Used Notes: Garage Converted to Living and UG Service Inspector Signature: Date: June 2, 2026 Town Hall Annex �� Gym Telephone(631)765-1802 54375 Main Road o P.O. Box 1179 N 2 Southold, NY 11971-0959 W • I BUILDING DEPARTMENT JUN - 8 2026 TOWN OF SOUTHOLD Building Dnpartrnent Town CERTIFICATION Date: Building Permit No. 3 3 Owner: VA0 t+hgeU) Z I-a j 4 I VI CV0X -P-r!5 [(Please print) Plumber:' , %Iq (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1%lead. /000 (Plumbers Signature) Sworn to before me this da r<< 20_law Notary Public, _County PAUL C CAPERNA NOTARY PUBLIC,STATE OF NEW YORK Registration No. 01 CA6151160 Qualified in Suffolk County Co 1 Commission Expires August 14,20 V? ho�apF SOUTyolo � � w ✓ mot - * # TOWN OF OUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION 1 [ ] FOUNDATION 1ST/ REBAR ROUGH PLBG. [ ] FOUNDATION 2ND ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: a C)k),IA��aA An Pee �16 -luvlq�nq ct, rf c DATE ® INSPECTOR ho��OF 50Ulyo� * TOWN OF SOUTHOLD BUILDING DEPT. ourm 631-765-1802 INSPECTION [ FOU DATI N 1ST/ REBAR [ ] ROUGH PLBG. [ ] UNDATION 2ND [ ] INSULATION/CAULKING [ FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ]. RENTAL E ARK : ' 4 IVA DATE INSPECTOR OF SO(/lyolo �W # . * TOWN O OUTHOLD BUILDING DEPT. 00UN1V N�'io 631-765-1802 17 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL Ltv REMARKS: �d DATE INSPECTOR ho�aOF SOpTh°!o # TOWN OF SOUTHOLD BUILDING DEPT. "Couto, 631-765-1802 ��/5 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I ULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: i C�A DATE ( p INSPECTOR i Armstrong Architecture and Planning 450 Cemetery Road,East Marion,11939 February 26,2026 Southold Town Building Department 54375 Main Road NY Route-25 P.O.Box 1179 Southold,NY 11971 Reference:Charters Residence 40 Madison Street Greenport,NY 11944 To Whom It May Concern: The installation of insulation at the above referenced residence has been satisfactorily completed as indicated on the approved permit drawings,and in compliance with all code requirements for The Town of Southold and The New York State Energy Conservation Construction Code. Best, Brina Arms g,RA �MST&O C� _�P ti0 4( _ tY n� Lli ' t 4 o6 g0 A: _T F � I.9 J U PJ 8 2026 EO ?, A 2025 RCNYS R324.4.3 Glazing in Windows Glazing in an individual fixed or operable panel that meets all of the following conditions shall be considered to be a hazardous location: 1. The exposed area of an individual pane is larger than 9 square feet(0.836 mz). 2. The bottom edge of the glazing is less than 18 inches(457 mm)above the floor. i I . The top edge of the glazing is more than 36 inches(914 mm)above the floor. 4. One or more walking surfaces are within 36 inches(914 mm), measured horizontally and in a straight line,of the glazing. Exceptions: 1. Decorative glazing. 2. Where glazing is adjacent to a walking surface and a horizontal rail is installed 34 to 38 inches (864 to 965 mm)above the walking surface.The rail shall be capable of withstanding a horizontal load of 50 pounds per linear foot(730 N/m)without contacting the glass and have a cross-sectional height of not less than 11/2 inches(38 mm). 3. _Outboard panes in insulating glass units and other multiple glazed pAnejs where the bottom._ edge of the glass is 25 feet(7620 mm)or more above grade, a roof,walking surfaces or other horizontal [within 45 degrees (0.79 rad)of horizontal]surface adjacent to the glass exterior. E E � � � J U Pi - 8 2026 �,{ ,;rst! a9c3 MGm ail Sarabia Construction <francisco@sarabiahome.com> Update on the Building Permit Application Matt Charters <mcharters90@gmail.com> Mon, Dec 8 at 5:35 PM To: Construction Sarabia <francisco@sarabiahome.com> Cc: Kaitlin Charters <kaitlincharters@gmail.com> Francisco: See attached. Shed has been here since house was built or shortly there after and was here / shown when I got the solar on my house in 2022. 1 believe I have a sketch from the title work when I bought the house that shows the shed application. Not sure how the wetlands are impacted as none of our setbacks on that side are changing, But it's over 100' from the house to the wetland. CO attached. Sent from my Phone On Dec 8, 2025, at 5:07PM, Sarabia Construction <francisco@sarabiahome.com> wrote: [Quoted text hidden] 1978-z Charters CO.pdf FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) \S, ------------------------------------ C FOUNDATION (2ND) lk uw y l ROUGH FRAMING& PLUMBING YA y s o. 1 � r INSULATION PER N.Y. �3 STATE ENERGY CODE G r wl uw. FINAL -. W 0 ADDITIONAL COMMENTS g q # -1-�c) P 11388 ZeD 2' oCv fo -cl A _ r 9.� b o � z d r� b o� 1701)"N UT SOU'1'HOLD— BUILDING DEPARTMENT Town Hall Annex 54375 Main Read 1". U. Box 1179 Southold,BUY 1 1 971-0959 'rele hone(63 H 765-1302 Fax (631) 765-95 02 h�s;[fwww.sout hold toavnny Date Received ►PPLECATI N FOR BUILDING PERMIT I Fur Office Use only +1- lT�C71 PERMIT NO.�� 3 5 Building Inspector._ Applications and fomis must be filled out in their entirety.Incomplete l applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date: iD l I y` OWNER(S)OF PROPERTY: Name: Matthew&Kaitlin Charters SCTM#1000- 41-1-2 Project Address: 40 Madison Street aka 756 Madison Street Greenport NY 11944 Phone#: 631-873-7315 Email: Mcharters90@gmailcom Mailing Address: 40 Madison Street,Greenport NY 11944 CONTACT PERSON: Name: f 914hI CI-SGo 5f'P-14161*1 Mailing Address: �,� , by Y. :y F iqs-r R AP-liom Phone#: `3 I_ -L�. , o r r 3 Email: u Sc0�5araloiAr'Lvme.Gown DESIGN PROFESSIONAL INFORMATION: Name: Armstrong Architecture&Planning Mailing Address: 450 Cemetery Road,East Marion,NY 11939 Phone#:631-338-5325 Email: Brina.Affnstrongl2@gmaii.com g @gmailcom CONTRACTOR INFORMATION: Name, 5A Aiq b q Cxr4SMUC,-np/4 rme. Mailing Address: .Q. QD -.e.f E AST 9�l0Iq tq 111301 Phone#: GN- 4 —0 I ' Email: wa-czd ezaRz1oiakome.corn DESCRIPTION OF PROPOSED CONSTRUCTION t ❑New Structure ❑Addition CrAlteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $ I Sly,v00.°i) r Will the lot be re-graded? ❑Yes FN0 Will excess fill be removed from premises? ❑Yes UNo , 1 PROPERTY INFORMATION xisting use of property: Ptr t wtc' " 1'Otrvte Intended use of property: r,(vv�vy �tryt,— Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? OYes EIJ'No IF YES,PROVIDE A COPY. i1 Chcck Box Adel'heading: The owner/contractor/design professional Is responsible for all drainage and storm water issues as provided by Chapter Z36 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit aulhorited inspectors on premises and In building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New Yoik State Penal Lava. I Application Submitted By(print name): 1-0 SC �. SOLY'CLIOI C. C Authorized Agent ❑Owner I Signature of Applicant: Date: t 011 q{ zS V—CO N%ETUNkCH STATE OF NEW YORK Notary Public,State of New York No.01BU6185050 SS: Qualified In Suffolk County COUNTY OF ) Commission'Expires April 14,.2. I Tose being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing_contract)above named, (S)he is the COVV+1-0-G'4' (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this i l4f1 day of_�C P Q-P/� 20 c ;( Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) i, Matthew&Kaif in charters residing at 40 Madison Street, Greenport NY 11944 do hereby authorize Sarabia Home Improvements to apply on my behalf to the Tow t Id Building Department for approval as described herein. 10/10/2025 Ow 1-1Si re Date 1/7 hew Charters & Kaitlin Charters Print Owner's Name r h�o�g�FFO�,�cOG y� BUILDING DEPARTMENT-Electrical Inspector * TOWN OF SOUTHOLD oy • Town Hall Annex-54375 Main Road-PO Box 1179-Southold, NY 11971-0959 Telephone (631) 765-1802 Temporary Certificate # oZ Date a o1U '— 2026 Customer Name Electrician Name �1-e&bjcl Address 7&Z Liq Q /Sl1h� /fie �' Phone a e-mail e-mail 0 !6gfi Lv/I�c rygcQ. Phone License# — 1p0 3 Size aaa A Phase / = Overhead Underground #of Meters Remarks #of Underground Laterals 1 2 New "H" Frame or Pole H P Fire Reconnect Was work done on Service? Y/ Flood Reconnect Old Meter# Service Reconnected Application for electrical service equipment is on file with the town of Southold.On the applicant's notification that this installation is complete,the town will conduct a premises inspection of the service equipment. This verification is valid for 90 da s from the date above. Authorized by / � ±m,�. liUIL;DING DEPARTMENT- Electrical Inspector i TOWN OF SOUTHOLD ear. FEB 2 2Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 �yTelephone (631) 765-.1802 I `:"•,ems, .-,:':c�" , APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: ;LJ2,02 2 Company Name: 10 kc •C Electrician's Name: A p,\ M `k.GS _ License No.: M� : _4p0 V6 Elec. email: Elec. Phone No: b l- p2, y, EE34 request an ema copy of Certificate of Compliance Elec. Address.: t3 c>gvC N IL JOB SITE INFORMATION (All Information Required) Name: e, Address: h ST ' VC a Cross Street: Phone No.: Bldg.Permit#: email: Tax Map District: 1000 Section: Block: I Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): 6 P41> CvC\v¢,)YS J0() &,u de r v�`� UeC)rV�Af Square Footage: coo Pr Circle All That Apply: Is job ready for inspection?: L7] YES ❑ NO Rough In ❑ Final Do you need a Temp Certificate?: ii] . I YES ❑ NO Issued On c15"2 Temp Information: (All information required) Service Size01 Ph❑3 Ph Size: �_A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect[OUnderground❑Overhead # Underground Laterals 1 , 2 R H Frame Pole Work done on Service? Y Additional Information: PAYMENT DUE WITH APPLICATION � - jib_� 2ro ;up PERMIT# Address: Switches i Outlets GFI's Surface Sconces H H's C Lts Frid a HW -POOL U g 4 Panel Fans Mini Fr. - W/D Pump Exhaust Oven Sump Heater ..Trnsfmr Smokes DW Generator Salt Gen. I I, Water Bond Carbc(n M.i.cro G.rb.Dis Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo ' % Cooktop M'inispIit Blower AC AH Hood Blower Service Am Use Have Amps ��"� d �- , Sub Amps Have Used Comments SURVEY OF: PROPERTY LOCATED AT GREENPORT TOWN OF SOUTHOLD SUFFOLK COUNTY. NEW YORK S.C.T.M. # 1000-41-1-2 SCALE: 1"=30' NOTE: THE EXISTENCE OF RIGHT OF WAYS, WETLANDS AND/OR EASEMENTS OF RECORD IF ANY. NOT SHOWN ARE NOT GUARANTEED. LAND N/F TOWN OF SOUTHOLD LAND N/F TOWN OF SOUTHOLD N 60 06 41 FENCE \ $rJ•� E FENCE 0.5'/w WtR 1.0�5 f m CONC. m MON. Z m m cn_3 ' m 0 AC v UNIT = 9G ® rn o O OQO�C/ zez sI N 0 '� �V - e SHED (P o LAND N/F 3.2'/W coNc. n co W IOANNIS F--� Z WAI-K rn m� a CE O MILONAKIS -0 a y r W CP A 9 W 5. = 4.9 o m FENCE L 2�' 0.6'/E �N NN o, 25.41 C �jy rn w 18.3 `P� !d y� �"0 � co J 14.3 X r cNo f m \v 0.507a2 J� AND s�0. PIPE S 87°36'50' CONC. POLE 60.84' WILMARTH AVENUE UNAUTHORIZED ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS SURVEY MAP NOT BEARING THE LAND SURVEYORS INKED OR EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. GUARANTEES OR CERTIFICATIONS INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED.AND ON HIS BEHALF TO THE TITLE COMPANY.GOVERNMENTAL AGENCY AND LENDING INSTITUTION SURVEYED B Y: LISTED HEREON.AND TO THE ASSIGNEES OF THE LENDING GUARANTEES OR CERTIFICATIONS ARE NOT TRANSFERABLE TO INSTITUTION. ADDITIONAL P A U L B A R Y L S K I LAND SURVEYING INSTITUTIONS OR SUBSEQUENT OWNERS. P A T C H O G U E NY 11772 CERTIFIED TO: PHONE 631-294-6965 MATTHEW CHARTERS FAX 631-627-3186 KAITLIN DANIELS CHARTERS PAULBARYLSKIiaYAHOO.COM FIDELITY NATIONAL TITLE COMPANY JUNE 15. 2020 10-15-2025: PROPOSED PORCH 4136-P T .P KII Compliance Certificate Project Information Project Title: 40 Madison Street Residence Energy Code: 2018 IECC Location: Southold,New York Construction Type: Single Family Project Type: Alteration Project Sub Type: None Climate Zone: 4a(5572 HDD) Project No: 1767920 All Electric: false Is Renewable: false Has Battery: false Has Charger: false Has Heat Pump false Construction Site: Owner/Agent: Designer/Contractor: 40 Madison Street Charters Armstong Architecture&Planning Greenport,New York 11944 40 Madison Street Greenport,New York 11944 Project Notes: Report Title: 40 Madison Street Residence Report Date: 10/7/25, 4:16 PM 1 of 11 Envelope Assemblies Prop. Req. Assembly Gross Area or Cavity Cont. U- U- Prop. Req. Perimeter R Value R Value Factor/ Factor/ UA UA F-Factor . F-Factor Ceiling:Flat Ceiling or --- --- --- --- --- --- -- Scissor Truss Exemption:Framing cavity not exposed. Wall:Wood Frame,16"o.c. --- Exemption:Framing cavity filled with insulation Windows:Wood Frame 173 0.290 0.320 50 55 SHGC:0.28 Front Door:Glass Door(over 20 0.320 0.320 6 6 50%glazing) SHGC:0.05 Back Door:Glass Door(over 19 0.320 0.320 6 6 50%glazing) SHGC:0.05 Basement Wall:Masonry --- --- --- --- Block w/Empty Cells Wall height:0.00 Insulation depth:0.00' Insulation position:Integral Insulation Exemption:Framing cavity not exposed. The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.It DOES NOT provide an estimate of energy use or cost relative to'a minimum-code home. Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck.Each slab-on-grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Compliance Statement The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. t tSps PXM sluNdn' (Name -Title Sign 6tj4 Date Report Title: 40 Madison Street Residence Report Date: 10/7/25, 4:16 PM 2 of 11 r Inspection Checklist Energy Code:2018 IECC Requirements:0%were addressed directly in the RESCheck software Text in the"Comments/Assumptions"column is provided by the user in the REScheck Requirements screen.For each requirement,the user certifies that a code requirement will be met and how that is documented,or that an exception is being claimed.Where compliance is itemized in a separate table,a reference to that table is provided. Pre-Inspection/Plan Review Section j.., l Plaris l `Field # Verified .s Verified' 1 &&"Re Pre inspection/Plan Review Value Value, ! `Complies? „ Comments/Assumptions 103.1, Construction drawings and Complies 103.2 documentation demonstrate Does Not [PR1]1 I energy code compliance for the [] I building envelope.Thermal Comply envelope represented on [2 Not construction documents. servable ei Not Applicable i 103.1, Construction drawings and Cj Complies I 103.2, documentation demonstrate 403.7 energy code compliance for d a Does Not [PR3]1 lighting and mechanical _ �q,i�o omply systems.Systems serving Not multiple dwelling units must servable demonstrate compliance with Not the IECC Commercial Provisions pplicable :3021, " Heating and cooling equipment Heating: Heating: Q Complies 403.7. ;. is sized per ACCA Manual 5 Btu/hr Btu/hr Does Not [pR2]r based on loads calculated per ❑ ACCA Manual I or other methods 0 Umply approved by the code official. Cooling: Cooling: Not - + Btu/hr Btu/hr servable P Not !I j�p'plicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2,° Medium Impact(Tier 2) 3"; ' Low Impact(Tier 3) Report Title: 40 Madison Street Residence Report Date: 10/7/25, 4:16 PM 3 of 11 ' r Foundation inspection _ $eCtio0 Pianst Foundation Inspection Value VaiuComplies� Comronts!Assumptions 303 2 1 A protective covering is r 0 Complies [FOl�jz installed to protect exposed - �` cr #axmin mum of 6 in.below grade. j " IDo ior insulation and extends M, � Pmply Not servable � PNot R h Pp l;cable n . t 403 9" Snow-and ice-melting system Complies [FO12]z {controls installed. _ 0, P � _ (�Does Not OM �" �21 ri ComPIY a Q Not Observable {]Not 'au '� Applicable 402.1.1+ Conditioned basement wall -1 ( 1 Complies See the Envelope [FO4]' insulation R-value.Where R R Assemblies table for interior insulation is used, Does Not values verification may need to occur R R-E= omply during Insulation Inspection.Not Not required in warm-humid servable locations in Climate Zone 3. Not pplicable 303.2 !Conditioned basement wall Complies [FO511 insulation installed per -= Does Not manufacturer's instructions. (] P R�� Comply Not servable Not pplicable k 402.2.9 i Conditioned basement wall ft ft O Complies See the Envelope [FO611 insulation depth of burial or Q Assemblies table for i distance from top of wall. C mply Not values Ob Not servable ; I Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) Medium Impact(Tier 2) Low Impact(Tier 3) Report Title: 40 Madison Street Residence Report Date: 10/7/25, 4:16 PM 4 of 11 .. Framing / Rough-in Inspection o, qr v , v ad �� ti _ a' i, _ - 3 Se t On Plans Feeld verified i verified (, Framing/Roug i to ,b si Rec toinspection� �� v �ue j vauuQ Gsmpiies�K = I Gom�n�nfislAsuropt�ons Ia 402.1.1, Glazing U-factor(area-weighted 1 []Complies See the Envelope 402.3.1, ?average). U= U Does Not Assemblies table for 402.3.3, values. 402.5 Comply [FR211 []Not Observable Ppp Not ` i licable 402.4.1,1 Air barrier and thermal barrier „m �gm 0 Complies [FR23]1 installed per manufacturer's �. hrro instructions. ,; Does Not iQ omply 9Not r GqP a servable I .0 Not Applicable 402.4.3 i Fenestration that is not site built �^A ��O Complies [FR20]1 is listed and labeled as meeting fi�` u AAMA/WDMA/CSA 3Pt ( Does Not 101/I.S.2/A440 or has infiltration `r �.. :comply rates per NFRC 400 that do not ❑Not i exceed code limits. �}[yu Observable I ° 9r;€ h ' Not � . . a pplicable 771, 402 4: IC-rated recessed lighting511 Complies [FR161� 1 fixtures sealed at 1 r (]Does Not housing/interior finish and " labeled to indicate<_2.0 cfm l 9 a Comply leakage at 75 Pa. F r; Not u Q � k ar servable 0 Not Applicable ." ,a, 403.3.1 iSupply and return ducts in attics v+�1 � Q Complies . insulated>=R-8 where duct is „ ,� [FR12] i>=3 inches in diameter andYt a (]Does Not li>=R-6 where<3 inches. ( � Ui��,& Comply Supply and return ducts in other ❑Not portions of the building { n NM servable insulated>=R-6 for diameter >=3 inches and R-4.2 for<3 " (�Not inches in diameter, i G Applicable 403.3.2 Ducts,air handlers and filter ^ �� Complies 1 boxes are sealed with [FR13] I mr Does Not joints/seams compliant with nternational Mechanical Code �r � % Comply i or International Residential (�Not Code,as applicable. a �� 9servable n � w a; O Not i Applicable 403:3.5 Building cavities are not used as Complies (FR1513 )ducts or plenums. , Does Not k "i+t5 x� vti'`iN 44 XY*46(] Comply AI� � n Not � VIrObservable (]Not Applicable ! 403.3.6(1 Ducts partially or completely a t �111 O Complies 2)[FR26]3 buried in ceilinginsulation have an insulation R alue not less F ���, �r� i(�Does Not than R-8,the sum of the ceiling Comply insulation R-value against and Not above the top of the duct,and g ' servable against and below the bottom of EE �� [ I the duct,is>=than R-19, Not excluding the R-value of the E 1 �. AAppplicable , ]duct insulation. Report Title: 40 Madison Street Residence Report Date: 10/7/25, 4:16 PM 5 of 11 j Section Plans Field �� #' Framing/Raugh In vee-i etl Verified I a6, t 4 &Req ID i 11 coon „^ Value Value Complies? g Commentslpssur�pt�ons" gt 403 3,7 Ducts declared to be within the a° "a�" , 0 Complies ([FR28]3 conditioned space are either 1) (( completely within the (]Does Not continuous air barrier and within ( j Comply the building thermal envelope, I [�Not {2)buried within ceiling i 06servable insulation in accordance with r e aafii' ' , �]Section R403.3.6 and the air Not handler is located completely k � a Applicable within the continuous air barrier and within the building thermals envelope and the duct leakage is<=1.5 cfm/100 square feet ` wH of conditioned floor area served by the duct system,or 3)the ceilingg insulation R-value m i installed against and above the t " 9 � ` insulated duct>=to the i I I proposed ceiling insulation R- f ` value,less the R-value of the insulation on the duct . ' 5 403 4 Nw a ;HVAC piping conveying fluids (= R(� 0 Complies above 105-F or chilled fluids l__J {below 55 QF are insulated to aR- (]Does Not (E 3• Comply i nNot j �iservable Not pplicable i 403.4.1 Protection of insulation on HVAC w '` a"°�[i 0 Complies [FR24]1 #piping. C Does Not j p(p v 't ,M "Na11 omply j �i (�]Not s Eiservable is i�Not plicable 403 5.3 S Hot water pipes are insulated to R R= 0 Complies [FR181? aR-3. (�]Does Not [ 3 Comply Not $ servable Not , ����� •., pplicable 403 6`" Automatic or gravity dampers 0 Complies [FR0 are installed on all outdoor air intakes and exhausts. Does Not ,aj """ -"•I 4r':m {,° j^,"zP l� '�*,� ii Comply lj r ' �Not ear m� xo OTiservable s( Not pplicable I ttr [FR4]13 I products arefdetermined in 4+n a )�idfi ,i� '0 Complies accordance with the NFRC test (]Does Not procedure or taken from the Comply I default table. 4 [�Not servable ONot licable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2, °;? Medium Impact(Tier 2) 3 °` Low Impact(Tier 3) Report Title: 40 Madison Street Residence Report Date: 10/7/25, 4:16 PM 6 of 11 Insulation Inspection Section t Plans Field Verified Verified i &Req IDS _ • Insulatwn Inspection,` Value Value Complies? Comments/Assumptions, 303.1 All Installed insulation is labeled ❑Complies [IN or the Installed R-values $ Does Not 1 provided. i omply Not servable Not k. pplicable P 402.1.1, Wall Insulation R-value.If this is I = R ❑Complies See the Envelope 402.2.5, a mass wall with at least 1/2 of R Assemblies table for 402.2.6 the wall insulation on the wall ❑Wood ❑Woodn Does Not i values [IN3]1 exterior,the exterior insulation Mass Mass `�"mply requirement applies(FR10). ❑ ❑ ❑Not ❑Steel ❑Steel Observable PI { plicable 303.2 Wall insulation is installed per Complies [IN4]1 i manufacturer's instructions. PoDoes Not mply I Not i Observable PNot pplicable �. 4 Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3.;, Low Impact(Tier 3) Report Title: 40 Madison Street Residence Report Date: 10/7/25, 4:16 PM 7 of 11 Final Inspection Provisions �' riL�R 4u'^'' 7xm ��ilRpe �le'rified Verified) a i , l &Iteq ID Penal Inspecf3on Rriovisions Value Value mCompi es? GOmmer tsfkssu�iip>ripns I �.402.1.1, Ceiling insulation R-value. R� R f� ❑Complies ;See the Envelope 402.2.1, 1� Assemblies table for 402.2.2, ❑Wood ❑Wood Does Not values Um ply [Fill' 6 I ❑Steel ❑Steel []Not Observable Q Not Applicable 303.1.1.1, Ceiling insulation installed per -0 a t �'" ❑Complies 303.2 manufacturer's instructions. i `' [FI211 j Blown insulation marked every Does Not 1 300 ft-. { " Comply Not servable Not Applicable a.. . 403 1;2 Heat pump thermostat installed n �$� Complies ❑ (F1101z 1 on heat pumps. , Does Not Comply [ Nip"I Not 1 R NO �' servable , ❑Not Applicable 403�5:1 Circulating service hot watery ❑Complies systems have automatic or 1 u accessible manual controls. �]Does Not II Comply a �� ` � , ❑Not Observable ,. ❑Not Applicable 4036:1 All mechanical ventilation [ �� S ❑Complies +[F12512 system fans not part of tested " and listed HVAC equipment 3 �1 Does Not meet efficacyy and air flow limits '�, :? omply per Table R403.6.1. + Not Observable �fi ��iah r ❑Not Applicable m ffl� Hot water boilers supplying heat E �ti � ❑Complies [FI261z ^ through one-or two-pipe ' Does Not heating systems have outdoor r ' setback control to lower boiler s a �' , omply water temperature based on Not ` outdoor temperature. ,Ica 9servable Not Applicable 403.5:1 1 1 Heated water circulation + , :❑Complies [P128]2 systems have a circulation pump.The system return pipe is Does Not !a dedicated return pipe or a �'�, k� �a��„Comply cold water supply pipe:Gravity k Not and thermos-syphon circulation h servable systems are not present. Controls for circulating hot f Not water system pumps start the ���r APPlicable �t pump with signal for hot water Id emand within the occupancy. n' Controls automatically turn off "Al, the pump when water is in f � circulation loop is at set-point r �x 'temperature and no demand for l hot water exists. „ 403 5`°1 2 Electric heat trace syystems ^_ ':r ❑Complies [FI29J2 comply with IEEE 515 1 or UL Does Not I 515.Controls automatically ��j d " adjust the energy input to the 3 Po ply f heat tracing to maintain the [�Not w ;desired water temperature in P v servable i the piping. ' r-­1 Not pplicable Report Title: 40 Madison Street Residence Report Date: 10/7/25, 4:16 PM 8 of 11 1 / Section plans `}� Field I Verified [ verified ( r .�,_ ....�....... . &Req ID I Final Inspection Provisions Value �t Value Complies? 'E Comments/Assumptions 4 403 5,2 %Demand recirculation water Complies [FI30]2 systems have controls that manage operation of the pump []Does Not wader enta�fntethe cold waterhe '' w` Comply 9 R (y��'�Not a piping to<=1049Ea4ra„ aG � UDservable I gJ Not .: lppplicable 403,54 Drain water heat recovery units �� Complies [FI31]2 tested in accordance with CSA B55.1.Potable water-side (]Does Not pressure loss of drain water f Comply °]heat recovery units<3 psi for Not individual units connected to Mservable one or two showers.Potable r Not water-side pressure loss of drain water heat recovery units<2r Applicable psi for individual units connected to three or more a„ showers. 404.1 90%or more of permanent +yr Complies [F16]1 fixtures have high efficacy ,�, � lamps. `,� Does Not ' s "i omply u 9Not I 6bservable 14 [�Not i pplicable ( 404.1.1 Fuel gas lighting[systems haveCJ Complies [F]23]3, no continuous pilot light. Does Not t Pmply []Not . Observable 'i �� tS°x2t Not i w 3 s r ,au A- pplicable .[Compliance certificate posted, 0 Complies 2 [FI7] ' { s n�'� �, Does Not Comply []Not Observable j° [jNot Pplicable 303.3, Manufacturer manuals for Complies [F]18]3 I mechanical and water heating ` t systems have been provided. o�Does Not [�Not a" servable j [ A�Not pplicable Ne 402 2. Vented attics with air_permeable baffle 0 Complies [FI22]z,~ insulation include ba aM t Does Not adjacent to soffit and eave + vents that extends over Comply insulation. 4 ❑Not 0 servable 1 a ('�Not . Oplicable [Fl3i' 4 insulation zR value and R�-1 R�1~ Complies [FI3] 1 adjacent assembly. �J �-1 Does Not Comply (('�]]Not !! 1iservable []Not P plicable [F11711.2 Blower door test@ n s Pa.<=5 AC AC Complies [FI17]1 I ach in Climate Zones 1-2,and ( �Does Not <=3 ach in Climate Zones 3-8. omply []Not I Observable ` Not I pplicable Report Title: 40 Madison Street Residence Report Date: 10/7/25, 4:16 PM 9 of 11 1 � Field #; Verified gg Verifletl" &Req ID Final Inspection Provisions 1, Value n a$ Value j ,,',Complies? Comments/Assumptions= 403.3.3 I Ducts are pressure tested to O Complies (FI27]1 determine air leakage with 1 either:Rough-in test:Total cfm/100 ft2 cfm/100 ft2 (]Does Not leakage measured with a Comply 1�pressure differential of 0.1 inch ((��Not 1 w.g.across the system including Pservable 1 the manufacturer's air handler j enclosure if installed at time of [[]]Not I test.Postconstruction test:Total Applicable leakage measured with a pressure differential of 0.1 inch r w.g.across the entire system including the manufacturer's air j handler enclosure. i 403.3.4 Duct tightness test result of O I 1 Q Complies [FI4]1 <=4 cfm/100 ft2 across the system or<=3 cfm/100 ft2 cfm/100 ft2 cfm/100 ft2 []Does Not without air handler @ 25 Pa,For Comply rough-in tests,verification may Not (� need to occur during Framing servable Inspection. I Not I pplicable 403.3.2.1 Air handler leakage designated ` e­ Complies [FI24]1 by manufacturer at<=2/o of design air flow. Does Not 11 Comply []Not Observable PNot plicable 403.1. " {Programmable thermostats Q Complies [F19]2 _;�Installed for control of primary heating and cooling systems (]Does Not and initially set by manufacturer Comply to code specifications. (�Not servable e []Not Applicable Additional Comments/Assumptions: 1 1 High Impact(Tier 1) 2°'�` Medium Impact(Tier 2) 3 Low Impact(Tier 3) Report Title: 40 Madison Street Residence Report Date: 10/7/25, 4:16 PM 10 of 11 EnergyJr Efficiency Certificate Above-Grade Wall 0.00 Below-Grade Wall 0.00 Floor 0.00 Ceiling/Roof 0.00 Ductwork(unconditioned spaces): Window 0.29 0.28 Door 0.32 0.05 Skylight 0.00 ® .. Heating System: Cooling System: Water Heater: Name: Date: Comments: Report Title: 40 Madison Street Residence Report Date: 10/7/25, 4:16 PM 11 of 11 -Ro ad COMPLY WITH ALL CODES OF APPROVED AS NOTED NEW YORK STATE&TOWN CODES _]a_(�_ 5a 5 33 AS REQUIRED AND CONDITIONS OF DATE•=Bq' 0�5 B.P.#FE0 BY:_dA _ SOUP.OIDTOV.TI U'Nli+u BOARS NOTIFY BUILDING DEPARTMENT AT .r..�...SOUiHOIDn"'ITRUSTM 631-765-1802 8AM TO4PM FOR THE us.DIG FOLLOWING INSPECTIONS: SOUTHOIDIrC FOUNDATION-TWO REQUIRED SCHO FOR POURED CONCRETE ROUGH-FRAMING&PLUMBING INSULATION FINAL-CONSTRUCTION MUST ELECTRICAL BE COMPLETE FOR C.O. INSPECTION REQUIRED ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS RETAIN STORM WATER RUNOFF provide ivlmdborne debris PURSUANT TO CHAPTER 236 OF THE TOWN CODE protection for new exterior glazing on bu='dings as per NYS Codewo Mechanical Ventilation PLUMBER CERTIFICATION system shall be required ON LEAD CONTENT BEFORE per NYS Energy Code CERTIFICATE OF OCCUPANCY SOLDER USED IN WATER SUPPLY SYSTEM CANNOT EXCEED 2110 OF 1% LEAD. PLUMBING ALL PLUMBING WASTE &WATER LINES NEED 40 S I TESTING BEFORE COVERING k I -A -A".. C ISSUED FOR PERMIT / CONS'TRUCTION OCTOBEk 6 , 2025 PROJECT INFORMATION PROJECT TEAM DRAWING LIST ADDRESS: 40 Madison Street �,� P�MSrR F o Greenport, NY 11'944 ARCHITECT: A-000 COVER SHEET � z�' ' Armstrong Architecture and Planning A-001 PROJECT INFORMATIO 'N m Y ZONING: R-40 450 Cemetery Road A-002 PROJECT INFORMATION East Marion, NY 11939 Tqr LOT SIZE. 10,57.5 SF 631.338.5325 A-100 FIRST FLOOR PLAN E 0 brina.armstrongl2@gmail.com A-200 EXISTING ELEVATIONS A-201 PROPOSED ELEVATIONS AREA CALCULATIONS: GENERAL CONTRACTOR: Sarabia Home Improvements A-300 SECTIONS P.O. Box 74 Proposed Main House Gross Floor Area.: East Marion, NY 11939 631.477.3918 First Floor: 1,442 SF francisco@sarabiahome.com AR.MSTRONG TOTAL: 1,442 SF ARCHITECTURE & O PLANNING Alterations to 40 MADISON STREET Greenport New York, 11944 COVER SHEET SCALE: Not To Scale OCTOBER 6, 2025 ABBREVIATIONS BUILDING DESIGN NOTES FRAMING NOTES & AND FIN FINISH R RISER 1. ALL ASPECTS OF THE DESIGN AND CONSTRUCTION OF STRUCTURES HALL CONFORM TO ALL LOCAL AND STATE CODES(SEE 1. ALL FRAMING LUMBER SHALL BE GRADE STAMPED DOUGLAS FIR-LARCH STRUCTURAL GRADE NO.2 FOR ALL JOIST CONNECTIONS.HANDLING,STORAGE,AND ERECTION OF ALL COMPONENTS SHALL BE L ANGLE FLR FLOOR (R) REMOVE RESIDENTIAL CODE OF NEW YORK STATE)THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY IF ANY OF THE DESIGNS ARE OR BETTER.ALL FRAMING SHALL BE NAILED IN ACCORDANCE WITH LOCAL AND STATE CODES(SEE AS PER MANUFACTURER'S SPECIFICATIONS. @ AT FO FAKE OF RAD RADIUS NOT WITHIN THE CODES OF THE STATE AND LOCAL AUTHORITIES. ATTACHED NAILING SCHEDULE) 4 CENTERLINE FRPF FIREPROOF RD ROOF DRAIN 12. ALL JOISTS SHALL HAVE 1 1/2"BEARING MINIMUM ON WOOD AND 3"MINIMUM ON CONCRETE OR 0 DIAMETER FT FOOT OR FEET REFG REFRIGERATOR 2• ALL HABITABLE ROOMS SHALL HAVE A CEILING HEIGHT OF NOT LESS THAN T-6",AND HALLWAYS,CORRIDORS, 2. ALL WALL SHEATHING SHALL BE APA RATED,EXPOSURE 1. 1/2",5/8",3/4"THICK(SEE DRAWINGS FOR STEEL(SEE MANUFACTURER'S SPEC'S FOR ENGINEERED LUMBER. FTG FOIOTING REINF REINFORCED BATHROOMS,TOILET ROOMS,AND LAUNDRY ROOMS SHALL HAVE A CEILING HEIGHT OF NOT LESS THAN T-0".BASEMENTS SPECIFICATION).SHEATHING SHALL BE NAILED TO FRAMING IN ACCORDANCE WITH LOCAL AND AN ADJUSTABLE REQ REQUIRED SHALL HAVE A MINIMUM CEILING HEIGHT OF T-0" (SEE R305 OF NYS RESIDENTIAL CODE FOR MORE DETAILS) STATE CODES(SEE ATTACHED NAILING SCHEDULE). 13 .ALL EXTERIOR WALLS SHALL BE 2X6 NOMINAL THICKNESS DOUGLAS FIR-LARCH NO.2 OR BETTER 161, AFF ABOVE FINISH FLOOR GA GAUGE RM ROOM O.C.MIN.INTERIOR WALLS SHALL BE 2"X 4"NOMINAL THICKNESS MINIMUM,SEE DRAWINGS FOR AMSL ABOVE MEAN SEA LEVEL GALV GALVANIZED RO ROUGH OPENING 3. BASEMENTS WITH HABITABLE SPACE AND EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPENABLE EMERGENCY 3. ALL SUBFLOORING SHALL BE APA RATED STUDD-I-FLOOR,EXPOSURE 1,T&G 3/4"THICKNESS.ALL SIZES. APPROX APPROXIMATE GL GLASS RR ROOF RAFTER ESCAPE AND RESCUE OPENING. OPENINGS SHALL HAVE A SILL HEIGHT OF NOT MORE THAN 44"ABOVE THE FINISH FLOOR. EDGES OF PLYWOOD TO BE SET ON SOLID BLOCKING.GLUE ALL SUB-FLOOR TO JOISTS USING ARCH. ARCHITECTURAL GLB GL,U-LAM BEAM MINIMUM OPENING AREA SHALL BE 5.0 SQUARE FEET AT ALL GROUND FLOOR OPEININGS AND 5.7 SQUARE FEET AT ALL ADHESIVE FOR THIS PURPOSE.ALL SUB-FLOOR TO BE NAILED IN ACCORDANCE WITH LOCAL AND 13. ALL WOOD FRAME WALLS SHALL HAVE A DOUBLE TOP PLATE(OVERLAPPING CORNERS)AND SINGLE AVG AVERAGE GND GROUND SALV SALVAGE OTHER OPENINGS. MINIMUM OPENING WIDTH(20"),MINIMUM OPENING HEIGHT(24"). (SEE R310 OF NYS RESIDENTIAL CODE STATE BUILDING CODES(SEE ATTACHED NAILING SCHEDULE). SOLE PLATE(MIN.)THE SAME LUMBER DIMENSION AS THE WALL.WALL BLOCKING SHALL BE INSTALLED GR GRADE SCHED SCHEDULE FOR MORE DETAILS) OF THE SAME DIMENSION LUMI3ER AT MID SPAN ON WALLS UNDER IY AND IN 1/3 INTERVALS IN BD BOARD GWB GYISUM WALL BOARD SECT SECTION 4. DOUBLE JOISTS SHALL BE SET UNDER ALL PARALLEL PARTITIONS. TALLER WALLS. BLDG BUILDING GYP GYPSUM SHR SHOWER 4. WINDOW WELLS SHALL BE DESIGNED FOR BASEMENTS WITH HABITAILE SPACE. THE MINIMUM AREA OF THE WINDOW BLK BLOCK SHT SHEET WELL SHALL BE 9.0 SQUARE FEET WITH A MINIMUM WIDTH AND HORIZONTAL PROJECTION OF 36". WINDOW WELLS WITH 5. DOUBLE JOISTS OR STRUCTURAL BEAM SHALL TRIM ALL STAIR,CHIMNEY,AND SKYLIGHT OPENINGS. 14. STUDS MAY BE DRILLED AN NOTCHED IN CONFORMANCE WITH R602.6 OF THE NYS RESIDENTIAL BM BEAM HB HOSE BIB SHTHG SHEATHING A DEPTH GREATER THAN 44"SHALL HAVE A PERMANT LADDER.LADDER SHALL HAVE A INSIDE WIDTH OF AT LEAST 12", SEE FRAMING PLANS FOR MORE DETAILS. CODE. BO BY OWNER HDR HEADER SIM SIMILAR SHALL PROJECT 3"FORM THE WALL,AND BE SPACED MAXIMUM 18"APART VERTICALLY.(SEE SECTION R310 OF THE NYS BOT BOTTOM HDWD HARDWOOD SED SEE ELECTRICAL DRAWINGS RESIDENTIAL CODE FOR MORE DETAILS) 6. JOISTS SHALL BE SUPPORTED LATERALLY AT ENDS BY FULL-DEPTH SOLID BLOCKING NOT LESS THAN 2" 15. ALL HEADERS SHALL BE AS SPECIFIED ON PLANS AND NAILED IN ACCORDANCE WITH THE NYS B'SPLASH BACKSPLASH HDWE HARDWARE SLR SEALER NOMINAL THICKNESS;OR BY ATTACHMENT TO A HEADER BAND JOIST,OR RIM JOIST,OR TO AN RESIDENTIAL CODE AND WFCM,IF THERE IS ANY DISCREPANCY OR IF A SPECIFICATION IS NOT HGT HEIGHT SPEC SPECIFICATION 5. ALL HABITABLE ROOMS SHALL BE PROVIDED WITH AN AGGREGATE GLAZING AREA OF NOT LESS THAN 8 PERCENT OF THE ADJOINING STUD;OR SHALL BE OTHERWISE PROVIDED WITH LATERAL SUPPORT TO PREVENT PRESENT,CONTACT THE ARCHITECT OR REFER TO TABLE R502.5 OF THE NYS RESIDENTIAL CODE. CAB CABINET HORIZ HORIZONTAL SS STAINLESS STEEL FLOOR AREA OF SUCH ROOM.THE MINIMUM OPENABLE AREA TO THE OUTDOORS SHALL BE 4 PERCENT OF THE FLOOR ROTATION. CB CATCH BASIN HR HOUR SSD SEE STRUCTURAL DRAWINGS AREA BEING VENTILATED(SEE R303 OF NYS RESIDENTIAL CODE FOR EXCEPTIONS)EVERY HABITABLE SPACE SHALL BE 16. ROOF BLOCKING SHALL BE SET TO ALLOW 2"AIR SPACE AT THE TOP OF THE RAFTER FOR VENTING. CEM CEMENT STD STANDARD PROVIDED WITH HEATING CAPABLE OF MAINTAINING A MINIMUM ROOM TEMPERATURE OF 68 DEGREES FARANHEIT,3 7. ALL JOIST TO BE BRIDGED WITH EITHER SOLID BLOCKING,DIAGONAL BRIDGING,OR A CONTINUOUS CER CERAMIC INSUL INfSULATION STL STEEL FEET ABOVE THE FLOOR AND 2 FEET FROM EXTERIOR WALLS(SEE SECTION R303 OF THE NYS RESIDENTIAL CODE FOR V X 3"STRIP NAILED ACROSS THE BOTTOM OF THE JOISTS PERPENDICULAR TO THE JOISTS AT 17. ALL CEILING JOISTS SHALL LAP A MINIMUM OF 3"AT SPLICE CONDITIONS OVER BEARING WALLS. CJ CEILING JOIST INT INfTERIOR STOR STORAGE MORE DETAILS) INTERVALS NOT TO EXCEED 8 FEET. CLG CEILING STRUC STRUCTURAL 18. THE ENDS OF EACH RAFTER OR CEILING JOIST SHALL HAVE NOT LESS THAN 1 1/2"OF BEARING ON CLKG CAULKING JT JOIINT SUSP SUSPENDED 6. THERE SHALL BE ONE HABITABLE ROOM WITH A MINIMUM FLOOR AREA OF NOT LESS THAN 120 SQUARE FEET.ALL OTHER 8. BEAMS SHALL BE NOTCHED AND DRILLED IN ACCORDANCE WITH R502.8 OF THE NYS RESIDENTIAL WOOD OR METAL AND NOT LLSS THAN 3"ON CONCRETE OR MASONRY. CLO CLOSET SYM SYMMETRICAL HABITABLE ROOMS SHALL HAVE AN AREA OF NOT LESS THAN 70 SQUARE FEET,KITCHENS SHALL HAVE AN AREA OF NOT CODE OR MANUFACTURERS SPECIFICATIONS FOR ENGINEERED WOOD PRODUCTS. CLR CLEAR KIT KITCHEN LESS THAN 50 SQUARE FEET.HABITABLE SPACES SHALL NOT BE LESS THAN TIN ANY HORIZONTAL DIMENSION (EXCEPTION 19. ALL ROOF SHEATHING ON ASPHALT ROOFS SHALL BE 1/2"THICK STRUCTURAL PANELS APA RATED, CMU CONCRETE MASONRY TB TOWEL BAR KITCHEN). (SEE R304 OF NYS RESIDENTIAL CODE FOR MORE DETAILS) 9. DRAFTSTOPPING SHALL BE REQUIRED WHEN THERE IS USABLE FLOOR SPACE BOTH ABOVE AND NAILED IN ACCORDANCE WITH THE NYS RESIDENTIAL CODE(SEE ATTACHED NAILING SCHEDULE). UNIT LAM LAMINATE TELE TELEPHONE BELOW THE CONCEALED SPACE OF A FLOOR/CEILING ASSEMBLY,DRAFTSTOPS SHALL BE INSTALLED SO CNTR COUNTER LAV LAVATORY T&G TONGUE&GROOVE 7. ALL DESIGNS SHALL BE IN CONFORMANCE WITH THE ENERGY CONSERVATION CODE OF NYS AND THE NYS RESIDENTIAL THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED 1000 SQUARE FEET(SEE R502.12 OF NYS 20. ALL WOOD ROOF SHALL BE COMPLETELY SHEATHED WITH 1/2"THICK STRUCTURAL PANELS APA COL COLUMN LB POUND THK THICK CODE(SEE CHAPTER 11 THE FOLLOWING GLAZING AND INSULATION VALUES SHALL BE USED ALONG WITH THE ENERGY RESIDENTIAL CODE FOR MORE DETAILS). RATED,NAILED IN ACCORDANCE WITH THE NYS RESIDENTIAL CODE(SEE ATTACHED NAILING COMP COMPOSITION LN LINOLEUM TO TOP OF )' SCHEDULE 5/4 X 3 SPRUCE LATH SHALL BE INSTALLED 16"O.C.PARALLEL AND IN LINE WITH THE CONC CONCRETE LT LIGHT TV TELEVISION CONSERVATION CALCULATIONS: )• G� CONC CONSTRUCTION LVL LAMINATED VENEER LUMBER TYP TYPICAL GLAZING U-FACTOR: .40 MAX 10. ALL PRESSURE TREATED MATERIAL SHALL BE PRESERVATIVELY TREATED AND DRIED AFTER ROOF RAFTERS 5/4 X 3 LATH SHALL BE INSTALLED PERPENDICULAR TO THE ROOF RAFTERS SPACED CONT CONTINUOUS CEILING R-VALUE:R-38(R-30 MAY BE USED AT SLOPED CEILINGS TO ALLOW FOR AIR FLOW) TREATMENT IN ACCORDANCE WITH AWPA C22.SEE DRAWINGS FOR DIMENSIONAL SPECIFICATIONS TO ALLOW AIR FLOW BEHIND THE WOOD SHINGLE ROOF FINISH. WALL R-VALUE: R-19 AND USES. CONTR CONTRACTOR MAX MAXIMUM UC UNDER COUNTER FLOOR R-VALUE:R-21 21. ALL FRAMING SHALL BE STRAPPED AS PER THE ATTACHED SCHEDULES WITH STRAPS MANUFACTURED CPT CARPET MC MEDICINE CABINET UNF UNFINISHED BASEMENT R-VALUE:R-10 11. ALL PRE-ENGINEERED LUMBER SHALL BE GEORGIA PACIFIC WI SERIES JOISTS(WOOD I-BEAMS),LVL BY SIMPSON STRONG TIE OR EQUAL SUBSTITUTIONS SHALL BE SUBMITTED TO THE ARCHITECT FOR MECH MECHANICAL UON UNLESS OTHERWISE NOTED SLAB PERIMETER:R-9(DEPTH OF 4') PRODUCTS,AND ANTHONY POWERBEAM PRODUCTS.ALL JOISTS,GIRDERS,AND HEADERS SHALL APPROVAL PRIOR TO INSTALLATION. DBL DOUBLE MEMB MEMBRANE CRAWL SPACE:R-19 HAVE BEARING STIFFENERS INSTALLED AS PER MANUFACTURERS RECOMMENDATIONS.WEB DEMO DEMOLITION MFR MANUFACTURER VERT VERTICAL STIFFENERS SHALL BE REQUIRED AT ALL LOAD AND BEARING POINTS. DOUBLE 1 3/4"LVL'S SHALL BE DEPT DEPARTMENT MIN MINIMUM VEST VESTIBULE 8. THE FOLLOWING CRITERIA WAS USED IN THE BUILDING DESIGN: INSTALLED AT ALL STAIR,CHIMNEY,AND OTHER FLOOR OPENINGS.SEE MANUFACTURER'S NOTES DET DETAIL MIR MIRROR VIF VERIFY IN FIELD DIA DIAMETER MISC MISCELLANEOUS WIND ZONE 130 MPH(3 SECOND GUSTS) DIM DIMENSION MTD MOUNTED W/ WITH EXPOSURE B DN DOWN MTL METAL WC WATER CLOSET GROUND SNOW LOAD 20 PSF DR DOOR MUL MULLION WD WOOD LIVE LOADS OF 30 PSF SLEEPING AREAS,40 PSF LIVING AREAS ENERGY NOTES DS DOWNSPOUT W/0 WITHOUT DEAD LOAD 15 PSF DTL DETAIL (N) NEW WP WATERPROOF DW DISHWASHER NIC NOT IN CONTRACT WRC WESTERN RED CEDAR 9. ALL DESIGNS REPRESENTED ARE PRESCRIPTIVE.IF ENGINEEREll DESIGNS ARE PRESENT,CALCULATIONS WILL BE SUPPLIED. DWG DRAWING NOM NOOMINAL WSCT WAINSCOT DWR DRAWER NTS N(OT TO SCALE WT WEIGHT 10. WIND BORNE DEBRIS PROTECTION(PER R301.2.1.2 OF THE NYS RESIDENTIAL CODE).}!"THICK WOOD STRUCTURAL PANELS SHALL BE PROVIDED FOR ALL GLAZED OPENINGS.STRUCTURAL PANELS SHALL BE FASTENED TO THE FRAMING IN THE TABLE R301.2(1) EXTG/(E) EXISTING OA O'VERALL EVENT OF HURRICANE FORCE WINDS TO PROTECT FROM WIND BORNE DEBRIS.PANELS SHALL BE FASTENED WITH 2%"#6 EA EACH OC OIN CENTER WOOD SCREWS @ 16"O.C.FOR PANELS LESS THAN 4",12"O.C.FOR PANELS GREATER THAN 4'AND LESS THAN 6',9"O.C.FOR CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA EJ EXPANSION JOINT OCC OCCUPANCY PANELS GREATER THAN C AND LESS THAN 8'(SEE R301.2.1.2 FOR MORE DETAILS). ELEC ELECTRICAL OFCI OWNER FURNISHED, ELEV ELEVATION CONTRACTOR,INSTALLED 11. ALL FRAMING SHALL BE NAILED AND FASTENED IN ACCORDANCEE WITH THE NYS RESIDENTIAL CODE ANDTHE WFCM.SEE WIND SUBJECT TO DAMAGE FROM ICE SHIELD ENCL ENCLOSURE OFOI OWNER FURNISHED, ATTACHED NAILING SCHEDULE AND FASTENER DIAGRAMS FOR DETAILS.THE ARCHITECT SHALL BE NOTIFIED GROUND SIESMIC WINTER UNDERLA- EP ELECTRICAL PANEL OWNER INSTALLED IMMEDIATELY IF ANY OF THE SPECIFICATIONS DO NOT MEET CODE REQUIREMENTS OR IF ADDITIONAL SPECIFICATIONS SNOW DESIGN FROST DESIGN YMENT FLOOD E EQUAL OFF OFFICE ARE REQUIRED. LOAD SPEED MPH CATEGORY LINE TEMP HAZARDS Q Q (MPH) WEATHERING TERMITE DECAY REQUIRED - E PT E UIPMENT OPNG OPPENING EQQP EXPANSION OPP OPPOSITE 12. ALL EXTERIOR FINISHES SHALL BE IN CONFORMANCE WITH THE NYS RESIDENTIAL CODE. DEPTH EXT EXTERIOR 20 PSF 130 MPH + B SEVERE 3611 MODERATE SLIGHT TO 11 YES PC POURED CONCRETE 13. ALL ROOF OVERHANGS SHALL RELIEVE ONE LAYER OF ICE AND WATER FROM THE OUTSIDE EDGE OF THE OVERHANG TO FA FIRE ALARM PERP PFERPENDICULAR A MINIMUM OF 24"INSIDE THE OUTSIDE WALL.ALL UNDERLAYMENT SHALL BE NAILED DOWN WITH CORROSION DECAY MODERATE FBR BD FIBER BOARD PL PRATE RESISTANT FASTENERS IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS. FBRGL FIBERGLASS PLAS PILASTER FD FLOOR DRAIN PLYWD RLYWOOD 14. ALL FLASHING SHALL BE SPECIFIED BY THE ARCHITECT AND/OR CONFORM TO NYS RESIDENTIAL CODE(SEE SECTION R905 1. ALL CONSTRUCTION SHALL COMPLY WITH THE 2015 INTERNATIONAL ENERGY CONSERVATION CONSTRUCTION FDN FOUNDATION PT PRESSURE TREATED FOR ROOF COVERING). CODE.THE AUTHORITY HAVING JURISDICTION SHALL BE PERMITTED TO DETERMINE AN ENERGY EFFICIENCY PTD PAINTED PROGRAM TO EXCEED THE ENERGY EFFICIENCY REQUIRED BY THIS CODE. 15. ALL MECHANICAL SYSTEMS SHALL CONFORM TO THE NYS RESIDENTIAL CODE,THE MECHANICAL CODE OF NYS AND THE E ARC FUEL GAS CODE OF NYS. 2. A PERMANENT CERTIFICATE SHALL BE COMPLETED BY THE BUILDER AND POSTED ON A WALL IN A SPACE WHERE THE FURNACE IS LOCATED.CERTIFICATE SHALL COMPLY WITH RC N1101.14. "� co 16. PLEASE REFER TO H.E.R.S.REPORT FOR MECHANICAL AND INSULATION SPECIFICATIONS. Af 3. ATTIC OR CRAWL SPACE ACCESS SHALL BE WEATHERSTRIPPED AND INSULATED TO A LEVEL EQUIVALENT TO THE UJ INSULATION ON THE SURROUNDING SURFACE. Q s - -� �, co 1. Y 4. INSTALLATION-THE COMPONENTS OF THE BUILDING THERMAL ENVELOPE SHALL BE INSTALLED IN ACCORDANCE ' ,` /� WITH THE CRITERIA LISTED IN TABLE 402.4.1.1.WHERE REQUIRED BY THE CODE OFFICIAL,AN APPROVED THIRD * - go SANITARY RISER DIAGRAM CONCRETE/MASONRY NOTES PARTY SHALL INSPECT ALL COMPONENTS AND VERIFY COMPLIANCE. 5. TESTING-BUILDING OR DWELLING UNIT SHALL BE TESTED AND VERIFIED HAVING LESS THAN OR EQUAL TO 3 -nh nrun:,6u,1 •`'^w,. Attic 1, ACH501N CZ 4A,5,6A.TESTING SHALL BE CONDUCTED BY AN APPROVED THIRD PARTY. vltl,riL�unr, ({{ lilt .: 1 1. MASONRY CONSTRUCTION SHALL BE DESIGNED IN ACCORDANCE WITH THE PROVISIONS OF SECTION R606 OF THE NYS 6. DUCTS-SUPPLY AND RETURN DUCTS IN ATTICS SHALL BE INSULATED TO A MINIMUM OF R-8 @ 3"OR GREATER IN Aw ":r Al INN `rat�Sttr'tUe RESIDENTIAL CODE OR IN ACCORDANCE WITH THE PROVISIONS OF ACI 530/ASCE 5/TMS402. DIAMETER,AND R-6 @ DUCTS LESS THAN 3"IN DIAMETER. « 2. ALL CONCRETE SHAL BE POURED IN AMBIENT TEMPERATURES OF 40+DEGREE F.IF POURING IN COLDER WEATHER,THE 7. DUCT SEALING-DUCTS,AIR HANDLERS AND FILLER BOXES SHALL BE SEALED. SOFFIT AI7�1� EAT C NEW EXTG., EXTG. EXTG. CONCRETE MUST BE PROTECTED FROM FREEZING FOR A PERIOD OF 14 DAYS(ADD MIXTURES CONTAINING CHLORIDES SEAL BATHROOM LAUNDDRY KITCHEN BATHROOM SHALL BE PROHIBITED). 8. DUCT TESTING-DUCTS SHALL BE PRESSURE TESTED TO DETERMINE AIR LEAKAGE BY AN APPROVED THIRD PARTY. 3. ALL FOOTINGS AND STRUCTURAL SLABS SHALL BE POURED ON UNDISTURBED VIRGIN SOIL,HAVING A MINIMUM BEARING 9. BUILDING CAVITIES SHALL NOT BE USED AS DUCTS OR PLENUMS. CAPACITY OF TWO TONS PER SQUARE FOOT. ARMSTRONG 10. MECHANICAL SYSTEM PIPING INSULATION CARRYING FLUIDS> 105 F DEGREES OR<55 F DEGREES SHALL BE "r TUE LAV WASI-1 SK TUB 4. ALL FOUNDATION WALLS SHALL HAVE A MINIMUM THICKNESS OF 8",ALL FOOTINGS SHALL HAVE A MINIMUM DIMENSION INSULATED WITH R-3 MINIMUM. SH WC DW LAV WC SH OF 8"DEEP AND 16"WIDE.SEE PLANS FOR ACTUAL FOUNDATION WALL THICKNESS AND FOOTING SIZES. ..,- ARCHITECTURE & , w- 11. MECHANICAL VENTILATION-SHALL MEET THE REQUIREMENTS OF THE IRCAMC. FIRST FLR 5. ALL CONCRETE SHALL BE 3000PSI AT 28 DAYS. - PLANNING IN G TO EXTG. 12. EQUIPMENT SIZING-PER ACCA MANUAL S,BASED ON LOADS CALCULATED PER ACCA MANUAL J AS PROVIDED BY A SEPTIC THIRD PARTY HERS RATER. 6. THE CONCRETE CONTRACTOR SHALL PROVIDE ANCHOR BOLTS,INSERTS,SLEEVES,ETC.AS REQUIRED BY OTHER SYSTEM Q TRADES.ANCHOR BOLTS SHALL BE SET PER NYS RESIDENTIAL CODE. SEE ATTACHED STRAPPING SCHEDULE FOR SPACING d EXTG. CO AND SIZE. 13. LIGHTING-A MINIMUM OF 75% OF PERMANENTLY INSTALLED FIXTURES MUST HAVE HIGH-EFFICACY LAMPS. j �„ k a, EXTG. HOUSE TRAP 7. ALL REINFORCEMENT SHALL BE TIED IN PLACE BEFORE CONCRETE IS POURED. AL REINFORCEMENT AND FABRIC FOR 14. ALL HVAC,PLUMBING&ELECTRICAL SYSTEMS SHALL MEET THE IRC CHAPTER 11 ENERGY EFFICIENCY, ga ` Alterations to INTERNATIONAL MECHANICAL CODE,INTERNATIONAL ENERGY CONSERVATION CODE.IT SHALL BE THE I` CONCRETE POURED ON GROUND SHALL BE SUPPORTED ON PRECAST BRICKS OR APPROVED CHAIRS. � 4 RESONSIBILITY OF THE GENERAL CONTRACTOR TO SUBMIT IN DETAIL THE DESIGN,CALCULATIONS,DRAWINGS, 8. LEGS OF REBAR ACCESSORIES SHALL BE PLASTIC TIPPED. ALL SNAP TIES AND WALL PENETRATIONS SHALL BE CUT BACK WRITTEN STATEMENT OF THE MECHANICAL,AIR CONDITIONING,VENTILATION,HEATING SYSTEMS(NEW, 40 MADISON AND GROUTED TO PRECLUDE ANY CORROSION. EXISTING,OR UPGRADED)STAMPED BY A PROFESSIONAL ENGINEER IF REQUIRED BY THE OWNER OR BUILDING DEPARTMENT. 1 _ ' 9. ALL REINFORCEMENT BARS SHALL BE CONTINUOUS EXCEPT AS NOTED,LAPPED PER AC1318,CLASS"C",WITH 40 STREET ,.. .. DIAMETERS MINIMUM,BENT AROUND CORNERS AND HOOKED AT NON-CONTINUOUS ENDS. FOR FRAMED SLABS,LAP 15. ADDITIONS,ALTERATIONS,OR RENOVATION;SHALL COMPLY WITH IECC 2015.UNALTERED PORTIONS OF THE ° -_ , TOP BARS AT MID SPAN BETWEEN SUPPORTS AND BOTTOM BARS AT SUPPORTS,REVERSE FOR FOUNDATION MATS. EXISTING BUILDING IS NOT REQUIRED BY THE OWNER OR BUILDING DEPARTMENT. STAGGER SPLICES AND OFFSET SPLICES OF BARS AT OPPOSITE ENDS. 16. MINIMUM ONE PROGRAMMABLE THERMOSTATS SHALL BE PROVIDED FOR EACH SEPARATE HEATING AND AIR SEALED WALL Greenp ort COOLING SYSTEM IN ACCORDANCE WITH SECTION N1103 CONTROL SYSTEMS. 10. ALL SLAB ON GRADE THICKNESSES SHOWN ARE MINIMUM THICKNESSES TO BE USED,INCREASE AS REQUIRED FOR 17. ALL EXTERIOR WALL/FLOOR/CEILING JOISTS SHALL BE AIR SEALED AND INSULATED IN ACCORDANCE WITH TABLE DRAINAGE PITCH. R402.4.1.1.APPLY A FRESH BEAD OF CAULK TO THE TOP AND BOTTOM PLATE IMMEDIATELY PRIOR TO INSTALLING New York, 11944 INTERIOR GYPSYM WALL BOARD. 11. SLABS ON GRADE SHALL BE PLACED IN STRIPS AND SHALL THEN BE SAW-CUT OR TOOLED TO PROVIDE CONTROL JOINTS APPROXIMATELY 20'O.C.,CONSTRUCTION JOINTS SHALL BE KEYED. 12. EXCEPT AS NOTED,ALL OUR STOPS SHALL BE TREATED AS CONSTRUCTION JOINTS AND SHALL HAVE KEYS AND INSULATION SPECIFICATIONS: FLAT CEILINGS:R-38 BATTtm CONTINUOUS REBAR. WALL SECTIONS SHALL BE PLACED ALTERNATIVELY OR WITH A MINIMUM OF 24 HOURS BETWEEN .. .w �« J VAULTED CEILINGS:R-30 BATT '` ' PRO ECT ADJACENT POURS. ?"' -A� - T FLOORS ABOVE UNCONDITIONED SPACE:R-38 BATT J ABOVE GRADE EXTERIOR WALLS:R-21 BATT IN 2X6 WOOD STUDS l 13. FOR CONCRETE WALLS,VERTICAL CONSTRUCTION JOINTS SHALL BE LOCATED AT A MAXIMUM SPACING OF 40 AT LEAST 4 T T ABOVE GRADE GARAGE WALLS:R-21 BATT IN 2X6 WOOD STUDS j AWAY FROM ANY SUPPORTING OR INTERSECTING WALL OR BUTTRESS,OR ANY WALL OPENING. - �' INFORMATION BASEMENT WALLS:R-15 BATT IN 2X4 WOOD STUDS 8,;, "A�eke , ... ! WINDOWS - GLAZED OPENINGS 14. HORIZONTAL CONSTRUCTION JOINTS WILL NOT BE PERMITTED EXCEPT WHERE NOTED ON PLANS OR SHOWN AN FOUNDATION WALLS:8",R-13 IN 2X4 ACCEPTED ON SHOP DRAWINGS. - . Not TO Scale ' r OCTOBER 6 2025 15. CONCRETE WALLS,DECKS,AND SLABS REQUIRING WATERPROOFING SHALL CONFORM TO AC1515. 1R-79 SPECIFICATIONS, MECHANICAL SPECIFICATIONS: r �•a ,•s:�e. r" ; .„I'"`:. ; I 1. FOR NEW CONSTRUCTION,EXTERIOR WINDOWS MUST'BE PROTECTED VIA:GLAZING MEETING THE LARGEST MISSILE TEST _ >95%AFUE GAS BOILLR CHAPTER 3 FOR CONCRETE SURFACE QUALITY AND FINISHES. CURING COMPOUNDS,RELEASE COATINGS OR ADD Q 715 SEER EQUIPMENT ACE " CERTIFICATION OF ZONE 1 ASTM E-1886-97 AND ASTM 996i-99 OR STRUCTURAL SHUTTERS WITH HARDWARE PROVIDED. MIXTURES THAT INTERFERE WITH THE ADHESION OF THE BARRIER MATERIAL SHALL NOT BE USED.LIQUID APPLIED Q 2. NEW STRUCTURES LOCATED WITHIN ONE MILE OF MEAN4 HIGH WATER MUST HAVE GLAZING CONFORMING TO WIND ZONE 1. BARRIERS SHALL NOT COVER,HIDE,OR LEVEL SURFACE IRREGULARITIES. MECHANICAL VENTILATION >110 CFM 3. ALL PROTECTION PANELS TO BE IN COMPLIANCE WITH LARGE MISSILE TEST OF ASTM E 1996 AND ASTM 1886,AS NOTED IN NYS RESIDENTIAL ONE ENERGY STAR BATH FAN WITH AN ELECTRONIC PROGRAMMABLE TIME CODE. 16. MASONRY OVER OPENINGS SHALL BE SUPPORTED BY STEEL LINTELS,REINFORCED CONCRETE OR MASONRY LINTELS,OR OTHER SPECIFICATIONS: MASONRY ARCHES DESIGNED TO ACCEPT LOAD IMPOSED. WINDOWS:U<0.28,SHGC<0.28 17. THE BOTTOM OF ALL FOOTINGS SHALL BE A MINIMUM OF 36"BELOW FINISH GRADE. >100°o HIGH EFFICIENCY LIGHTING(CFL's OR LEDs) } -001 THESE PLANS MEET 2018 :ICC RESIDENTIAL CODE AS <3 AIR CHANGES PER HOUR DUCT SEALING REQUIRMENTS 18. ALL CHIMNEYS AND FIREPLACES SHALL BE DESIGNED IN ACCORDANCE WITH CHAPTER 10 OF THE NYS RESIDENTIAL CODE. ALL APPLIANCES MUST BE ENERGY STAR CERTIFIED ADOPTED BY THE NYS 2,020 RESIDENTIAL CODE / U n , , ` ~ ~ � LEGEND: EXISTING BUILDING NEW WORK WINDOW SCHEDULE WINDOW NO. MFTR. PRODUCT# OPERATION FINISH ANDERSEN PROVIDED TRIM EGRESS F SCREENS NOTES J ——— EXISTING REMOVED ALTERED 101 (2) WDH2656 DOUBLE-HUNG WHITE DRIP CAP,3-1/2"FLAT CASING,SILL NOSE J / 102 WDH2656 DOUBLE-HUNG WHITE DECORATIVE DRIP CAP,3-1/2"FLAT CASING,SILL NOSE J J 103 WDH2656 DOUBLE-HUNG WHITE DECORATIVE DRIP CAP,3-1/2"FLAT CASING,SILL NOSE J J 104 WDH2656 DOUBLE—HUNG WHITE DRIP CAP,3-1/2"FLAT CASING,SILL NOSE J J 105 WDH26310 DOUBLE—HUNG WHITE DRIP CAI',3-1/2"FLAT CASING,SILL NOSE J ELECTRICAL KEY 106 ANDERSEN 400 (2) WDH2656 DOUBLE—HUNG WHITE DRIP CAP,3-1/2"FLAT CASING,SILL NOSE J / ALL WINDOWS IN EXTG. SERIES WALLS,EXCEPT 107 WDH3432 DOUBLE—HUNG WHITE DRIP CAP,3-1/2"FLAT CASING,SILL NOSE / WINDOW 112,TO USE EXTG. ADJ. DOWN LIGHT V HEADERS,HEAD HEIGHTS 108 (3) WDH2656 DOUBLE—HUNG WHITE DECORATIVE DRIP CAP,3-1/2"FLAT CASING,SILL NOSE J / TO MATCH FRONT DOOR ® FIXED DOWN LIGHT v THROUGHOUT. 109 WDH2446 DOUBLE—HUNG WHITE DRIP CAP,3-1/2"FLAT CASING,SILL NOSE J FIXED DOWN LIGHT WET LOCATION 110 WDH2446 DOUBLE—HUNG WHITE DRIP CAP,3-1/2"FLAT CASING,SILL NOSE J ]11 WDH2446 DOUBLE—HUNG WHITE DRIP CAP,3-1/2"FLAT CASING,SILL NOSE J SURFACE MOUNT 112 (3) WDH2656 DOUBLE—HUNG WHITE 3-1/2"FLAT CASING,SILL NOSE J J �0 CLOSET LIGHT DUPLEX OUTLET HALF-SWITCHED DUPLEX OUTET TV T TV LOCATION ISWITCH -ALL SWITCHES TO HAVE DIMMERS JAI JAMB ACTIVATED SWITCH OC' rC � rC P05T POST POST POST 2 26'-Oz" VIF 7'-1 4" 7'-1 4" 7'-1 4° N FRONT PORCH r-————-� II IIO 3 3 8'-54" 11'-44" IOI GARAGE CONVERSION TO PRIMARY SUITE - NEW WOOD FLOORING INSTALLED ON I Iz ( I NEW SUB-FLOOR AND FR.,A41NG. g FINISHED FLOOR ELEVATION OF 1 „ 2 1 I „ 771 CONVERSION TO ALIGN W1 FIN15H FLOOR 2-3 I O-12 VIF 2'-3" 5-82 4-1 14 - - ELEVATION OF EXTG. HOP✓AE. EXTERIOR WALL FRAMING FO REMAIN; NEW WINDOWS IN NEW OPENINGS I I I ( CL. NEW INSULATION AT FLC, 5, WALLS, Iog I Io III AND ROOF. - NEW HVAC UNIT LOCATED ABOVE BATH 2 I TO SERVICE NEW PRIMARY SUITE NEW INTERIOR DOORS(4) TOTAL -- BEDROOM I PRE-FINISHED WOOD FLOORING IN HALL - LIVING ROOM (105), CLOSET, *PRIMARY BED(10( 14'-73" VIF _I, /O'-9'3" O IOI Io6 ��FtE� RC' - BATH 2(1 1 O) TO HAVE TILE FLOORING, 4 �° 3'-1 13, `� 3° - NEW WINDOWS IN PR S riQ AND TILE TO WAINSCOT 11EIGHT ON p 2-7„ 4 - NEW WINDOW IN I EXTG. OPENINGS P WALLS N mId- 1`71 ENLARGED OPENING CL. I - PATCH AND REPAIR - GWB FINISH ON WALLS AND CEILINGS �'J W - PATCH AND REPAIR e►. U.O.N. W c��d WALLS AS NEEDED CASING AS NEEDED sas - PRIMARY BEDROOM TO HAVE GABLED ILn - Ioz - * �, CEILING; EXTG. COLLAR TIES TO HAVE ® TO X I J. 0 O� DECORATIVE, PTO. WD. WRAP � ,9 D4069 - INTEGRATE BATH EXHAUST WITH RETURN GRILLE IN BATH 2 c�l� Io8 rr� I� _ — OF NE Lj N PRIMARY BEDROOM _ _ _ _ _ — CL. 3,, _ m 3 _ HALL - - - - - - It+.s X 13 r 31JJ"ice � 44 I� 44 T A I O BA E11 E T I Ios W r-IN o � � �' � - NO NEW WORK P'n � 74 PurP°�-S f cJ T� - - - - �F - - ARMSTRONG cD OFFICE KIITCHEN DINING ROOM CL. R Io6 ARCHITECTUE & 103 Ioz ° - NEW WINDOWS IN HALL J - NEW WJINDOW IN EXTG. - NEW WINDOW IN EXTG. 0 EXTG. OPENfNGSLJ+ PLANNING I —IN OPEAWNG OPENING - PATCH AND REPAIR Io8 I J - PATCHIAND REPAIR - PATCH AND REPAIR CASING AS NEEDED —� — CA51WG AS NEEDED CASING AS NEEDED PANTRY L — I ow _ � Alterations to DEMO WALLS; NEW WALLS PER PLAN 4 O MADISON - PATCH AND REPAIR FLOOR WHERE REQ'D BATH I - NEW CABS. C70P io Io6 Ios 107 Io4 NEW SURROUND FOR STREET EXTG. W/D I I I _ NEW WINDOW IN EXTG. - EXTG. EXT. DOOR TO OPENING REMAIN - PATCH AND REPAIR CASING AS NEEDED Greenport New York, 11944 FIRST FLOOR PLAN SCALE: 4" "= 1'-0 OCTOBER 16, 2025 I Proposed First Floor Plan Ili MST c -- -- - IX s 40 4 p 4 Existing South Elevation 3 Existing East Elevation t�200 1/4" = 1'-0" 1/4" = 1'-0" ARMSTRONG ARCHITECTURE & PLANNING Alterations to -- 40 MADISON STREET Greenport New York, 11944 - EXISTING ELEVATION SCALE: ill = 1'-0" OCTOBER 6, 2025 2 Existing North Elevation z Existing West Elevation A 2 1/1/4" = 1'-0" 1/4" = 1'-0" A- 100 'I i PROVIDE NEW 3-1/2"CA51NG AT EXTG. DOOR TO MATCH ANDERSEN TRIM REPLACE EXTG. GARAGE DOOR W/NEW WALL W/NEW WINDOW O 0 413 o Tq TE OF _ o 0 0 0 ARMSTRONG 4 Proposed South Elevation 3 Proposed East Elevation ARCHITECTURE & A 201 1/4" = 1'-0" t 1/4" = 1'-0" PLANNING �— PROVIDE NEW 3-1/2"CASING AT EXTG. DOOR TO MATCH ANDERSEN TRIM 5x6 VER5ATEC COLUMN WRAP AT PORCH, Alterations to -- 'yp ALL TRIM TO 8E 40 MADISON NEW ASPHALT ROOF AT PORCH ------ — — - PROVIDE 5", 'HARDIE'4 SMOOTH TRIM, TO MATCH EXTG. REPLACED WITH RAKING FASCIA AT GABLE ENDS IF POSSIBLE WITH EXTG. ROOF _ 'R a SMOOTH STREET ROOFING TO REMAIN TRIMIM B BOARDS; TYP. Greenport IF GUTTERS NEED TO BE REPLACED, REPLACE W/ New or 11944 WHITE HALF-ROUND GUTTERS AND ROUND REPLACE ALL DOWNSPOUTS B.O. PORCH BEAM SOFFITS W/ -- ALIGNS w/B.O. HOU5E 'HARDIE' EAVE CEDARMILL SOFFIT PANELS NEW, WHITE ANDERSEN PROPOSED 400-5ERIE5 WINDOWS W/ I I O O 02 ANDERSEN TRIM O o ENHANCED TREX I 2 DECKING AT NEW'HARDIE PLANK'LAP SIDING - ELEVATIONS PORCH AND STEPS; SELECT CEDARMILL, 0 COLOR TBD EXPOSURE, COLOR TBD SCALE:i" = 1'-0" OCTOBER 6, 2025 z Pf oposed NorthElevation I Proposed West Elevation. 1�Z�I 1/.1" = 1'-0" 1/4" = 1'-0" A-201 II �I 2" PLYWOOD ARCHITECTURAL ASPHALT 33 ROOFING 4 c� C\l 4 it VENT SPACE yjpwowh 4" VENT SPACE W/SCREENING B.O. PORCH BEAM TO V-GROOVE BDS. ALIGN W/ B.O. HOUSE ON -Lit 8" FIN . BEAM 3" OVERHANG SAVE 12 CyT Q / . 5 ��—NEW PORCH ROOF NEW ARCHITECTURAL ASPHALT ROOF �U / WILL NOT HIT EXTG, TO MATCH EXTG. ROOF, OVER (2) ni r 3 Section Detail @ Porch Beam SOLAR PANELS LAYERS OF 30# FELT, OVER 2"COX PROVIDE NEW * _ INSULATION IN EXTG. 3 it-Off2X8 ROOF FRAMING _ PLYWOOD ROOF SHEATHING, OVER FRAMING AS REQ'D cP� 40 A 300 — +9'- O-1/4 „ T.O. LEDGER l GOOF RgF7ERS @ 6„o +8 3-3/4 „ �x6 GL71dG �OfST� (� 16_O.C. T.O. BEAK (3) 2X8 PORCH B.O. PORCH BEAM TO ALIGN w/B.O. ENHANCED TREX S71-RUCTUF:AL BEAM HOUSE SAVE � DECKING 5X5 VERSATEX COLUMN WRAP; TYP. 5-411 ARMSTRONG " VENT SPACE (3) 2X8 ACO PORCH EXTG. FRAMING; TYP, 4 W/SCREENING BEAM z ARCHITECTURE & 6xi6 ACO STRUCTURAL D POSTS, w,HEAVY o GALVANIZED PLANNING = i GAILVANIZED POST � i —IN ANICHORS @POURED ,z CONCRETE o FOUNDATION, TYP.Off o� 3 EXTG, FF FFL IN NEW PRIMARY Alterations to SUITE TO MATCH FFL ENIH'ING, TREX 40 �D I S O N DEiCKING, COLOR TBD. IN EXTG. HOME co +O'- O " +O'- Off T.O. 1 sT FLOOR FF T.O. 1 sT FLOOR FF STREET [2:x�ACQ PORCH JOISTS @ I G"0. INSULATE FLOOR Greenport CAVITY New York, 11944 / / EXTG. FOUNDATION 14"'0 50NOTUBE _"= z // WALL AND SLAB —IN PIEK5 UNDER / co POFRCH COLUMNS m / SECTIONS / SCALE. 1" = 1'-0" / 4 COMPACTED, OCTOBER 6, 2025 GRANULAR FILL EXTG. FOUNDATION WALL 4 Section Detail @ Porch Deck a Porch Section 1 Section @ Primary Bedroom A-300 A 300 3" = 1'-01, A 300 1/2" = 1'-0" A 300 1/2" = 1'-0" U tn9� u Ih ldt 0150 a . i � IIIltllllll 11 11 111111111111111 I' _ D�sa aBla aoo,,,Mc C y