Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
51372-Z
�O0�pf SOUTyo`o Town of Southold P.O. Box 1179 • +0 53095 Main Rd co„ Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 47264 Date: 08/04/2026 THIS CERTIFIES that the building SINGLE FAMILY DWELLING-ADDITION AND ALTERATION Location of Property: 1600 Alvahs Ln Cutchoaue, NY 11935 Sec/Block/Lot: 102.4-8.1 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 09/25/2024 Pursuant to which Building Permit No. 51372 and dated: 11/12/2024 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Additions and alterations including an attached deck with a hot tub and an outdoor shower to an existing single-family dwelling as applied for. The certificate is issued to: Moltz-Ahuja Living Trt Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: R-24-1083 12/16/2024 ELECTRICAL CERTIFICATE: 51372 6/30/2025 & 50767 7/11/2025 PLUMBERS CERTIFICATION: Richard J. Cannarella 6/l/2026 l Auth ' ed Si ature �o��oFsa�ryo(o TOWN OF SOUTHOLD BUILDING DEPARTMENT ' Q TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51372 Date: 11/12/2024 Permission is hereby granted to: David Moltz 259 Clifton PI Brooklyn, NY 11216 To: Construct deck addition and interior alterations to existing single family dwelling as applied for,with SCHD approval. Premises Located at: 1600 Alvahs Ln, Cutchogue, NY 11935 SCTM#102.-4-8.1 Pursuant to application dated 09/25/2024 and approved by the Building Inspector. To expire on 11/12/2026. Contractors: Required Inspections: Fees: Single Family Dwelling- Addition&Alteration $536.50 CO Single Family Dwelling-Addition/Alteration $100.00 T al $636.50 Building Inspector Town Hall Annex Telephone(631) 765-1802 54375 Main Road P.O.Box 1179 Southold,New York 11971-0959 oum,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: David MOltz Address: 1600 Alvahs Ln City: Cutchogue St: NY zip: 11935 Building Permit#: 50767 Section: 102 Block: 4 Lot: 8.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Electrician: Drago Electric License No: 44135ME SITE DETAILS Office Use Only Commercial Indoor Basement Service Solar Residential X Outdoor X 1st Floor Pool X Battery Storage As-built Renovation 2nd Floor Hot Tub X EV Charger New X Addition Attic Spa Generator Survey Mezzanine Garage Dock INVENTORY Service 1 ph In-wall Heater Recpt Ceiling Fixtures Smoke Detectors Pump 3 Service 3 ph Hot Water GFCI Recpt Wall Fixtures 5 CO Detectors Heater 2 Main Panel A/C Condenser Single Recpt RecessdFixtures Combo Smoke/CO Transformer 2 Sub Panel A/C Blower Range Recpt Ceiling Fan Heat Detectors Salt Gen Transfer Switch Mini Split Dryer Recpt UC Lights Fridge AutoCover ARC Blower Heads Switches Pucks Lights Dishwasher Mini Fridge GFI SepticDisconnect Emrgency Strobe 4'LED Microwave Garbage Disp. ARC/GFI ERVI I Exit Lightsi I Bath Exhaust Hood Dehumidifier Other Equipment: Pentair Intellitouch 10 Circuit/10 Used , 30OW Transformers, Blower Notes: Pool anq Hot Tub Inspector Signature: Date: July 11, 2025 O��pF SOUT�oI � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G • Q Southold,NY 11971-0959 UNT`I1 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: David MOItZ Address: 1600 Alvahs Ln City: Cutchogue St: NY Zip: 11935 Building Permit#: 51372 Section: 102 Block: 4 Lot: 8.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Drago Electric License No: 44135 SITE DETAILS Office Use Only Indoor 1✓. Basement F Service r Solar F Outdoor F 1st Floor ry Pool F Spa F Renovation F 2nd Floor I✓ Hot Tub F Generator F Survey Attic I— Garage Battery Storage Ln Service 1 ph F Heat Duplec Recpt 2 Ceiling Fixtures 2 Bath Exhaust Fan 2 Service 3 ph F Hot Water GFCI Recpt 5 Wall Fixtures 2 Smoke Detectors 3 Main Panel A/C Condenser 1 Single Recpt Recessed Fixtures 2 CO Detectors Sub Panel A/C Blower 3 Range Recpt Gas Ceiling Fan Combo Smoke/CO 2 Transfer Switch UC Lights $' Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 6 4-LED Exit Fixtures Other Equipment: Fridge, Oven, Hood, DW, Micro, Septic Disconnect, Minisplit w/ (3)Blowerheads Notes: Kitchen & (2) Baths Inspector Signature: Date: June 30, 2025 Sean Devlin` Electrical Inspector sean.deviin(cD-town.southold.ny.us 1600AIvahsLn Kit&Baths Town Hall Annex `~. Telephone (631)765-1802 54375 Main RoadCD t'r P. O. Box 1179 L Southold, NY 11971-0959 a JUN 18 2026 BUILDING DEPARTMENT Building De.par#mont TOWN OF SOUTHOLD Town of Southold CERTIFICATION Date: / 70 ca— Building Permit No. 7 Z Owner: `Ja vi� �® /�Z- (Please print) Plumber -�AO-XD '� , 0, (Please print) I certify that the solder used in the water supply system contains less than 1- 0 of 1% 1 (Plumbers Signature) i Sworn to before me this day of -�� 20 2-(. PublARIAic c-State Gof LEY Ne FNotary Public-State of New York NO.01PR5003206 Qualified in Suffolk County ommission Expires Oct 19,2026 Notary Public, ,fro( �C- County 1 QjF SOUIyO�o # TOWN OF SOUTHOLD BUILDING DEPT. �o� �a� 631-765-1802 INSPECTION [/] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) ( ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: �,t�tt I rl 401 t'D /;Z RNA- 0 lam C&ry-7 fz 0e--- �U DATE INSPECTOR �I3�� ho�aOESOUTy�� * # TOWN OF SOUTHOLD BUILDING DEPT. coorm��''� 631-765-1802 INSPECTION FOUNDATION 1ST/ REBAR [ OUGH PLBG. [ ] FOUNDATION.2ND [. ] INSULATION/CAULKING []'FRAMING /STRAPPING [ ] .FINAL [ `] FIREPLACE & CHIMNEY [ ] FIRE'SAFETY INSPECTION [ . ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PREVO [ ] RENTAL REMARKS: -koellumv - DATE INSPECTOR UF SOUlyolo '�) 2, /"' eo AA " v L \ - - - # # TOWN OFSOUTHOLD BUILDING DEPT. 'cnorm 631-765-1802 INSPECTION ' [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] -FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: Q , w4aieLf—_L/ 04 oAl (j /0&?,i (sue DATE INSPECTOR SOGTyolo o'-07 ` 1 & o6) A vA;-vs- LA # . # TOWN OF S UTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING ( ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: � M 4 DATE INSPECTOR a SOUTyo� -- - — # TOWN OF SOUTHOLD BUILDING DEPT. . . : courm, �o 631-765-1802 INSPECTION. [ ] FOUNDATION 1ST/ REBAR . [ ] ROUGH PLBG. [ ] F NDATION 2ND [ ] INSULATION/CAULKING. [ FRAMING /STRAPPING) [ ] FINAL [ ] . FIREPLACE & CHIMNEY' [ ] ,FIRE SAFETY INSPECTION [, ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] REN AL REMARKS: DA tz f-w 0 co C& DATE INSPECTOR �o�apF SO(/Tyolo s i 7 A V a4, # TOW OF SOUTHOLD BUILDING DEP `you 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] .FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANTrCONSTRUCTION [ ] -FIRE RESISTANT PENETRATION ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL. REMARKS:_ -Ir«uAk �-t-Q2rG DATE INSPECTOR SOUTyOlo ® # # TOWN OF SOUTHOLD. BUILDING DEPT. Quo,� 631-765-1802 I.-NSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION'2ND . [ - ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE-SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION j ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: 6e'4w( 6 424,vMvta_l<_ Lelo Co tn LI tNl vow �25IG 'S. �P-1 teL 1 41� WjdW DATE INSPECTOR SObTyOlo .9�0 7 # _ TOWN OF 0UTHOLD BUILDING DEPT. eourmN�' 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ELECTRICAL (FINAL) [ ] CODE VIOLATION [ /] PRE C/O [ ] RENTAL REMARKS. •�— rrX IAcoy r DATE 4& INSPECTOR OF SOpTyolo * # TOWN OF SOUTHOLD BUILDING DEPT. rou �o 631-765-1802 /' 1 NSPECT' ® N [ ] FOUNDATION 1 ST/ RERAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] IN ATION/CAULKING [ ] FRAMING /STRAPPING FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: ro pa,,,K��vl�� l J �OJal/ Ao sov OrA� 44/\- kw, sz+ S w _ pot DATE IO INSPECTORA / ,51 3 07 2- AM P Architecture Address:10200 Main Road,Unit 3A,Mattituck NY 11952 Design + Build Phone:(631)603- E C E July 24, 2025 AUG 2025 Moltz Residence �us� 1600 Alvahs Lane Cutchogue, NY 11935 7'Gwn of oz�f�cc�8d SCTM #1000-102-04-8.1 To Whom It May Concern. Based on my inspection at the above address the ceiling framing was installed per the architectural plans and meets NYS Building Code. Please contact ou r office if you have any questions. Thankyou, Anthony Portillo, RA, LEED AP C -,RIED Apt EAR /40 0 ®� eN��,, Page 1 of 1 ' -5-,1372 AMP Architecture Address:10200 Main Road,Unit 3A,Mattituck NY 11952 Phone:(631)603-9092 Design + Build January 29,2025 y Moltz Residence ,JAN 3 0 2025 1600 Alvahs Lane Cutchogue, NY 11935 SCTM #1000-102-04-8.1 To Whom It May Concern. Based on my inspection at the above address the insulation was installed per the architectural plans and meets NYS Building Code. Please contact our office if you have any questions. Thankyou, Anthony Portillo, RA, LEED AP tp -_ 3E..� 7A, „4•r' �J in Page 1 of 1 FIELD INSPECTION REPORT DATE COMMENTS V' FOUNDATION (IST) FOUNDATION (2ND) r z 0`K- . o me 9 ROUGH FRAMING& I !/ hl PLUMBING r _,�..n W N - — r INSULATION PER N.Y. '3 STATE ENERGY CODE - 7-a3•�- C �. �R.t�lS d 2f.� U n �� � (I2 Gc 1Mv'l�f� � FINAL t2 a,�auZ�s l�s U L201 co �"� out s a2s L ADDITIONAL COMMENTS Vh Scj c'e-r-� reG'et ve, ao ( v rn .�� 2 re. o If CL vl cc., ,ya v t c ko . •n U O z � x r � i x b i ' �St1FF0(��o TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtonM.Rov f Date Received APPLICATION FOR BUILDING PERMIT i - D LP Cc: 0� For Office Use Only 2 �' u LLtddd PERMIT NO. j�a— Building Inspector: S E P 2 5 2024 Applications and forms must be filled out in their entirety.Incomplete IP- DING DE PT. applications will not be accepted. Where the Applicant is not the=owner,`an TO WN 4r SOUTJ.710I Owner's Authorization form(Page 2)shall be completed. ' Date:09/24/24 OWNER(S)OF PROPERTY: Name:Kavi Moltz SCTM# 1000-102-04-8.1 Project Address: 1600 Alvah's Lane, Cutchogyue a _. Phone#:917 612 566 Email kavl.ahuja@gmail.com Mailing YAddress: 1600 Alvah's Lane,Cutchogue CONTACT PERSON: Name:Brooke Epperson Mailing Address PO Box 152,Matti tug k,, NY 1.1952 Phone# 631 603 9092 Email:bepperson@p�Mpqrchitect.com DESIGN PROFESSIONAL INFORMATION: Name,Anthony..Portil!9, Mailing Address:PO tBox 152,A M,atttugk,.N xY M11952 Phone#.631 603 9092 Email aportillo@amparchitect com CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ®Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other Interior Kitchen Alteration and deck/hot tub addition $100,000 Will the lot be re-graded? Eyes ®No Will excess fill be removed from premises? ®Yes El No 1 PROPERTY INFORMATION Existing use of property:Single Family Residential Intended use of property:Single Family Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to AC Non-Conforming this property? ❑YesANo IF YES, PROVIDE ACOPY. 8 Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided'by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By rint name):AMP Architecture BAuthorized Agent ❑Owner Signature of Applicant Date: Oj 74 24 STATE OF NEW YORK) SS: COUNTY OF Q"0\\<_,a- ) being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing ontract) above named, (S)he is the ( ntractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this J 1 G� day of ed IeMbe( , 20D4 Notar Pu c =QuOified FENANGER PROPERTY OWNER AUTHORIZATION NOTATE U NEW YORK .01A00019644 (Where the applicant is not the owner) uffolk CountyCores January 9,2028 I� Kavlta Ahuja Moltz residing at 1600 Alvahs Lane Cutchogue do hereby authorize AMP ARCHITECTURE to apply on my behalf to the Town of Southold Building Department for approval as described describedherein. Digitally signed by Date:2024.02.2313:19:07-05'00' Sept. LT, 20 24 Owner's Signature Date Kavita Ahuja Moltz Print Owner's Name 2 ^.2r BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 ®y.�j®� Telephone (631) 765-1802 - FAX (631) 765-9502 iamesha-southoldtownny.gov - seand@southoldtownny.ctov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: [ 2, 1) a2 q Company Name: �c to o Wit_ecC� Electrician's Name: ���qR`O OcR c7 License No.: KF-- L-AW4kZ> Elec. email: Orq a c.\-e-c���cl_.� @ GMAAk, 0-6 Elec. Phone No: Rn (.o5 ❑I request an email copy of Certificate of Compliance Elec. Address.: t-t 5o 9,0oSe'J o-�7\ JOB SITE INFORMATION (All Information Required) Name: �V,o\Z Address: �Q;4, Lo C c�► o o L Cross Street: Phone No.: 'ot 5�.c,, Bldg.Permit#: 5 email: z�T-tct.'\ @ Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: V►rA11 Circle All That Apply: Is job ready for inspection?: ffyES NO Rough In Final Do you need a Temp Certificate?: YES NO Issued On Temp Information: (All information required) Service Size❑1 PhF-]3 Ph Size: A # Meters Old Meter# ❑New Service[]Fire ReconnectOFlood ReconnectOService ReconnectOUnderground overhead # Underground Laterals 1 2 F1 H Frame D Pole Work done on Service? Y DN Additional Information: PAYMENT DUE WITH APPLICATION wo , ob p A 1"4,-�i-�-q BUILDING DEPARTMENT- Electrical Inspector l r ' TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 . }� Southold, New York 11971-0959 Telephone (631) 765-1802 FAX (631) 765-9502 ia�nUsh so�;tr,oiGt�rr�n�.ao�i a sea..n;d(cJ�ouih�id.or%rnnn gg APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: i 0 Company Name: Electrician's Name: License No.: t� - '-t�-1135 Elec. email: �rq ��.�����ct.3 �1A G �L, Ca f Compliance Elec. Phone No: (:kv`l `���`- G05 ❑I request an email copy of Certificate o Elec. Address.: C13u �coS�u �`—� s ` `'J`��� '� ' "-y OL JOB SITE INFORMATION (All Information Required) Name: vkzz) �7- Address: r 6 Occ \.J.-n" - Cross Street: Phone No.: Bldg.Permit #: �0-7 (Q7Z email- Tax Map District: 1000 Section: Block: Lot. BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection? ffyES ❑ NO Rough In El Final Do you need a Temp Certificate?: YES O NO Issued On Temp Information: (All information required) Service SizeFT Ph 03 Ph Size: A # Meters Old Meter# New Service®Fire ReconnectOFiood ReconnectOService Reconnect[]Underg round[]Overhead # Underground Laterals 1 2 H Frame 0 Pole Work done on Service? Dy N Additional Information: PAYMENT DUE WITH APPLICATION K0- I?r C. 4��� PERMIT# Address: Switches Outlets GFI's Surface Sconces H s UC Lts Fridge HW POOL Fans Mini Fr. W/D Panel Pump-/ ?j Exhaust Oven Sump HeateNAp - /16 Trnsfmr Smokes DW Generator Salt Gen. �dv� p ' Carbon Micro GrbDis Water Bond I OA/zlfw Lights I Zoyf) S'- Heat Pucks ERV Z HOT TUB/SPAI Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower l/ AC AH Hood Blower Service Amps Have Used Sub Amps Have Used Comments << $ugFpl���� BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD t Town Hall Annex - 54375 Main Road - PO Box 1179 col �. Southold, New York 11971-0959 q - Telephone (631) 765-1802 - FAX (631) 765-9502 _. iamesh@southoldtownny.gov - seand@southoldtownny.aov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: ( a If -a2`-! Company Name: SJctA Electrician's Name: �.flgR`p Oct, c7 License No.: KIE_- �-A\-Ak3'j Elec. email Ca Elec. Phone No: Rn Goy ❑I request an email copy of Certificate of Compliance Elec. Address.: cT 3o s K, vyCL JOB SITE INFORMATION (All Information Required) Name: VVA _L Address: \6 c>o C-._ Cross Street: Phone No.: (.'01 6Lc,, b 6 G c�\ Bldg.Permit #: 5\-!D`1,a- email�c�, oe� ec�<<� �� �Gt�IA�L, ca Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Y,Ac, -Juk -1 ` �j��Ca�� i�t a Sc�or c=\ ��co Square Footage: V►rAvl Circle All That Apply: Is job ready for inspection?: EdYES ❑ NO Rough In Final Do you need a Temp Certificate?: YES NO Issued On Temp Information: (All information required) Service SizeFT Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service[]Fire ReconnectOFlood Reconnect[]Service Reconnect[]underground(]Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? MY N Additional Information: PAYMENT DUE WITH APPLICATION wo® o b f2M k 0 ''C-) " PERMIT# Address: i S witchesAr Outlets GFI's ap Surface Sconces �1 H H's s� UC Lts ' Fridge HW POOL Panel Fans Mini Fr. W/D Pump ` �� Sum Exhaust l Oven p Heater Trnsfmr Smokes ' DW Generator Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc , Combo Cooktop Minis plit . Blower GNA Hood Blower I I Service Amps Have Used Sub Amps Have Used Comments i A M P Architecture Address:10200 Main Road,Unit 3A,Mattituck NY 11952 Phone:(631)603-9092 Design + Build January 20, 2024 Southold Town Building Department ! 54375 NY-25 FEB 1 3 2025 Southold, N.Y. 11971 A - ^� RE: Moltz Residence 1600 Alvahs Lane �C"-we" ` Cutchogue, NY 11935 SCTM #1000-102-04-8.1 Dear Southold Building Department, Attached I have the updated plans of the main house & rear deck for the Moltz Residence that reflect the changes made to the dwelling during construction.The changes are as follows: Floor plan: - Updated insulation table - Updated foundation plan with new stairs - Updated window&door schedule - Updated rear deck access hatch - Updated kitchen layout&floor plan notes - Updated bathroom layout Site plan: -Updated pool deck -Updated septic location - Modified buried service lines Updated Pages Include: -G-001 -G-002 -A-101 -A-102 -A-201 -A-401 Please contact me if you have any questions or additional requirements regarding this application. Sincerely, Anthony Portillo, Principal AMP Architecture, PLLC 631-603-9092 Page 1 of 1 I sEFT c TANK-T-LIT-s-ANCARos v ® / ���jp .,e ) [ A6RIGLLnRu LMq:,a rna[e L comae wnPw:m Meta oMs I-I eett'c _ to me•.l-1.raPLAN VOT[5 LAN. 'Gc.GG' s, eolme,roae�=`L�,Ipte:Sbe. cle VI rsevtk I..o,atry .a.a.n,.:e .yM'N�,�: slsEe PRaPER-Y ,y9 \� �..e, _ L er> etrelrg• _rro k eolmey Depe•emene or Lm.r Pau cmle�rcroee�:..�a m- e a x �r aHo x �1/ hg ew Lonwror ANar.p�maI!e 1 n 5A1m k Lamy Lem mP am°neea. ,�,'p ✓EK i0 ROOF P5 RFd.L PROP NEI6HBGQIN6 5 bg-tti T+w Depvtme ox L cemmg aw Lmn•.+-er All- Otn-5 ter.• c-1 e m be H"a i' ,+ 'Y•%J � r //It _ WELL O R- SGG-5 i '` Q maNeoro a oat m' 'coca uA LTv 5 Ma.[crow.Preulmro. 3 - o d o V y YYY } 3 �P ZO-o PoL`-F D Ti 3R Or.e0%:SAMPLtNs=olwrl: REF NO R-_O-GOOF a. nt err L Ra:cns(wtN o Iro.uvm h�prcctbn el./mw o- ` SEPARAibh FRO.+k£ALH N6 W CLS/A Oh 5.9 MIA. A cvii5 Nt ti w os<rea nt-r Ne Deowtment n qum�'vcro v e mnlm.+ �t er prope•ly lava.a �•{.. \\""" - 'fir,, �., the swro k cwnw semt�y coca comp«ba>aro nraa p _ t�"�` '><- !.t7)))y��. (s PROP N.pCLEAN xARM/ccaITRDL PA"=, .eIn gc I w b Un Depmvtmrn:g•u'Ha wblkotwn of eemp ate. ( ' 7�g` ® ELELTRv:AI Lp.'E FROM UA OhTS I I M mntrvctnn w- ai tt'P am. gc iwu twn m><Fro.e w[cl A �• �• V' `R LIV 'l O PROPOSED M N N's E �_y� ✓"-Y- PQOP N.AMPL AIR.BLOhLR•]'m wL AIR L NE T H 6H EV:.E i5-ER NY$- I Q N 5.An urte Wotan wo Montawcc Lent/«t xwcen ew %+ra s< ms -Pane«n'wb c�..Int..>a / CC���1r x „��y:. Y �-' 'A OwT51>rR MAta SPEe,S: POOL CODE \I Of C O I-te•ttcnorc Pro mr ma=report,e..xr mot tw xan ttca<Nc m n :y Door x Deo:stronl� �• \ t I 18 Deoatmcnt prbr b oee•crat el 4c/A OM5 rea aVatlo.b8 tw AAA`,;i 4 �y C%eT cTIL STD'TO BL ABANDCNTT PCR ti(il 7 Depwtmcnt Ir c-.:cc wl,l A.-:c e=d role 5.f10 t County A t rro xptK:cr:k must be o•wwe.w N o,D- O } Swttay com.o-Car moo e::,ment opprwea mn a a.bw�w h ro rvJ or '0�! p PQCP clew-w*"ISTALL wl N o'o�ales Fouler. If - a/A DWTS aer 'n tog �co ea for oc enar.ct o^Wne e>mao \ j_ 4,•.O� ;• �... I I O C N Z O ` J ..y IV �1 SITE LAYGU-NG-ES: fl Wa[arb operouw mo tcro+ceaae� •emmnwroeo f Inge I e m eecn a r,e w T- {, �_ S•fj' _ I TNS 15 AN ARLHt-EO7'5 5IT_PLAN t 15 T U at aa�arat on mMnroWsnpw<aary «t Hm 5.M it.of rro/4 OWTS ask w wk ero rot be m f \\\G444yq�'•�'y��1 ,Sr pr cPn ty o.ncn Prc expectco b ma na Hnm epera:br grcatcr tllm 35 reet or e>a Nor ow lao�belmn IKo a �•• /p��f-;.psi ' ,/!'�.^Tq L:IT'.5 I / SJBJELT TO VERI=1°ATION B-'A LICENSED C C O 7 N orv«:r acm-mrca neh Irtkb IP d w - L r.1 ')xw '� m. _ ip SJRVEYOR THE 11.rORNATION O O y(p Sullo k LovMu Son lml.Cooe b Al o m nhan o tarp ha marts es arm rove]0-Inch ceeree e M` 9.D 9;Y Qp 1 ZPZ52NrD ON TH S SITE PLAN IS TO THE 0 open s b roam tocetec wer tNt r ct wo Rut.L _' f�,�A�` 'y'�'`t �1 '• it �• Do AQGHITECTS BEST OF KNOWLEDGE C NO le g.awn a/P onr_ree,r..o.coca Ne„n t sho t be ronbtl eo be e.>xw o-WCF coach,nawrt'gn ero 'rla, Q a O rml d ero reswewe aavy serves.Vent�Ppas ab °.tow o Lisccc-prml« s o•nwrmop Dark eo,en ere '�Zj� vvS. �P "�"'� I v'gyp of b Wcrm about vc rml w Uw top of Un van: I' sno x 1t IIIrr^^.:sjj `ST�' 1 FROM A SURVEY DATED APRIL 05 a024, >ho hove°mnemlm hr..antal sepaatian al 13 n4ca to rro 5w a om.t�ae sat rro c ma g•e°In o>eerocwa wth sactlon �.` ry L YS• �Ilf:y®15'i y �c EL.=1-I.O]' ='SURVEY IAFORMA-ION)•!AS 03T 4INED d Ne roof.+case•Mere It a > 3 ISSF Ldl! MOST C=OEYi-Y REVI5EV-MAE 26,3034, sloped pwuon wl vmtka to `_'ti! A-'REFIRED B•': n ut sate...m Ne-es eexe rod.°renl pinPWe mtly ee ptpee a -.wxn awlP:w..Fern..wo opprwcc x x Hxonae W o I �+.9c. I a' ro,eerce mw�rmlro[e a Npm d 1D h.e> tl Me my a p>kAg see.Ne mw e a a n11 ba m>h ee be LOCATION MA of AAS P �<q T YOUNG ASSCCIA E5 gg d!•om property Wcs TFcx rat Vofl c ry t Ve regvre+enta H 30 w bceioe-vco o•n.tier..d 3 lcet Irmm mru..wm.:y hE-]O SG.ALL:NT$ / lcr+-rote.-t•°cabw II,-mvkc All rat I `\ I RI VCR EID.w Pcl .w,t Have°mnr.•-c:o ebr e•2 wlca D T,e vctlw sro x c m ran,.of OI lod bob. TEL OETRAI.DER AVE23 PP..m.,> v<Fa t I uv. _ ' - �- : \ 1 /n TEIEFHON'E-'t51.T.-23C3 I.r>blbttr ao:,era err Ne vA cars muse cower..b N< FRO.�GT!1 ZONING CATA - 70 - DepwG<nta opprace. _gvleac oorrrart prepweo r °Se'rP ra t>>,a1 awe :n m mmrata d L feet cr w I I EYAIl.tiNINGYCUNGENGINEERIAG.CGN A-I Apprw va Harwcamert el nsa veer o �eee eu 3 rme a TAX NAF a IOC.. 02-G.-6.I 1 C) Irrovo4va ea Alb+n•-i.•e^rste has:e.ota.Tradm<ni S,sblm- U c ya1:x c mex�m,m rctcnt"v ecpV mlmn tra wtlet invert ZONING D15TRIC- AG Iv^N-GONPOR.MIK6 `\\\ I D MNlasp+Dfs 6t.REOL REMENTa: elevmt dart rota. CI) I,A Oa/r5•septk ewes sro I x mm4uc -1 F oco>t 1...rtyh ppe pewerotmra rue>mPlre-1.sane m LOT GOVERA.�E ti 4• .•..• --� - �K m b./Itcrg ».pe�uulex.Pec)prepybz t moptmeks.w .r t /J oNcr mdego 1, arbront«mr ce MN Cep atwooroa wer ' loN'rcRR.opera'.„Ts-A Tw na a se.e tone a prehplbe. E_ECTRI.u ¢EN,BNrs.. 50LJT1-D_D TONW GOCC ISEG ION 280 124)� tg 1 3.areas w/A OnF...Tres a mPt c tank rro preveotmert rro LCATRO 5. -, %_OT AGRICULTURAL ALSLST 3 20=+ »�Ptk LOIk steal teas N»ctem s-OT I Tile p bo be G a weal..w°su tobla DESCRIFTiON(FOOTPRINT) AREA �COVE¢A6C ��00 LAND S-10a o'N's> :getl n«cwtlawe nl �eoesbl wer the strvctwe Jwt t aervea.A bmdlveq,the porol \ m pt EXIST,E%TERIOR NOSE TEST HOLE.2 DATA V .m:ayrbe mounted w w rot>ioe not el Ne svrcwe(yetermle Nay ' BIB M.WA-ER SUPPLY I MCDONALD GEOSEQV G 5 9.LNIe»othernlw apeclrteo.rro eacning atrve[ure/system trot a ut111eywer we a Itv'ro speed.CVer Ioemlms ler n:ecnu.y IOTA_LOT AREA 424'Ib S.F. - N `LINE CONNECTED TO Pi 135E fellow w I'A tJIYrS.1.1 be eealowtl 1n't:..rca HIM»c['w Nc pmel row.11,be cmmbcreo a.:w Gepart+nnt an° \. H I� I /THIS=IX1/RE ONLY I SO - I- �( , S-IOr aw 1-e+N's sward. tom-rod-c..e bmb aw nit,I'A-1 monroceser epprevd. EXISTING DWELLING 1,115 S.F, eb% 1 Y p , ______ __/___ - I (651)T65-56,OM C`Il II VA O VemNknt rants•ee�tt toots awl[ Tln romc or Nc I/A OMS Gets=rev ecr mast m c1cw18 EXISTING GOVEREG PORCH IBI S.F, 0.4% _ -_----_- / '- ^` MCDGEOg6MAILL rove1. � wan covcrca xsc»opcnrys to god. oteo ever tw motor.on trn arowe N ew Pae wer In.I:wc o Pnow nmxr \ NOTE CMANGEIBI w I EL,v)g. .IDD' a W aw oath[.Gwcro s,c1 m VKr 2o-alrh damcbr notcrtlor- to con[«[W emu d alarm EXISTING 5TEPS FROM DWELLING •••^•• I I EXIST.1-5-Y hD. Q aw Nast-prml«ray cast'ro+cwcn w[Fcrmoplm[k cwci> 3<5: C.1% /' FR.5UILGIN6•+: COL DARK BROWN LOAM ere 1-1 q Iaoa.A I coven wer cnrrwyt_.sb11 m msigwe W s.Extcria pewl�laxmcrt era c>vo e:nmm to x scrvkco ere (TOWARDS DRIVEWAY) \ /- occa .h»ctkm 5-II d VI>stawwe. Nn cleniwt Ne weer m access Nc Wkn d�ro bullolrg. -\ /• DECKS(DRY BLDbJ 5.Wwn o 1/A OWt5 v>apt'c ev<b epvwee b m senito W a r«ITMa peel hex:vst be niNn vtn o•Ne sysbn[..[leas b wP EXISTING AOGC-_SORT 6AQASE 352 5 F. 0.5% _ _- - wWenoy a pakirg weer.b<unit swtl be tleaion0 rob/or tart eperdlen aw m°ntcwrcc. t D BROHAI gILTY SAt� Imtallea to nI--HS-20 a F-30 Iooery ea m>Igwbe Ivg M-.Rawl sro I m�b.m d°mmlwtmlc In'yrm la EXISTING TRE.LIS I56 S.F. 0.4% T.WE EXI$--I I 3D MTh SRA/CL AnSrrto. «mss:+a ease rJ a Ex•oww MewPcmer:t Axrcc EXISTING SHED PRG _ O BE 9 SLATE 5' 1 Irri anon Well mLHIA)Il000:are rcgvre,cones r IOI 5F. O2% IRONED M N� b.GvuPgeg�mrs troll rue.m pwln"tbo.IMn m I/A CMS h (To 6E RELOCATED.I PATIO urn d stooge cmosal b the >ro11-It Vauaot=_loot d MONlawen SGDHS REF.NO. ' EXISTING r--•'EG R-30-O-^.Ob NO Wda adlcron rail rot oac,wtaeW AFOWT:a !x A _LMA;4x aGcclrKotk'a.rL [70 REMAIN; TG2 S.F. FRG. MIN. 1N 1 tm..elec`e�cceezee caar.em eo - t•, n.Wa m„>:bo etcrket 50'MIN NIN --;, FRO a.so dacl..oa.bo .A,, Est'o°�F�r o[e> vart oma_on:rai>We EXISTING N.FR.BLDG.•./DECKS lay g F. G5% E(` ` L: - Ixpvtmerltl. a TP.s.w Nllage WIIEIry -It wwl V mrtr.!pw<I w<4perem.ee ea 5p PROPOSED RAISED DECK a./HOT ^ 1 MIN -LE B.Ii�c tub I>e�tK Iwks mabbel tztt zt su tot m D^EPN'>Ietem a aolb agvopee olrmctzt �rw� m TL'B a OUTDOOR SHOWER 2B3 S.F. - 1 rn a w. uX � I TE=T Flap SAID _ SOLE°- PRO CL.=IP32' .=...slue ce+m:en a ee - en m0 Revd b.the occ art of Ne bi 1pFe server..Tlmy PROPOSED II.GROUam POOL on a�C b DeoP-tmen!recemmewa a nroay ocvk.be hablletl to E%ST.b'-0'HG1i vrt'g.«.Tan IratroGs d°nuringewt> a ee ylmetlbte romoe.olwn :c°:Im to Ease O>M provlmr S GGMDE FEFLE w _ ndert fe�sne be dtror v harry w rwev pro a bstlly Previr TOTAL AREA OF ALL STRJOTURES 3;165 S.F. b.H% W/WIRE ME-r-H;FEtLE I _ metro.. rolbro: mve ee V•J ew OSM«seamen GOMP_IE5 AS FER-5 _ uvn ba:hg:Sera ex a w4 opplyoo v ovum to roe r�mm wer°to be eat aeslgnee to f Ion w orwlt�ve WAXIMJM LOT COVERAGE ALLOWED:305E POOL CODE r--___ -- �--------------- Al (4)rKMaflOOmn;.•mercury. Is approve II 90b d eamwc M a Pafabb FPPatltn:tn a ce Vo�PPro Ito meom d PROPOSED oo vaewm b hale Iw 4uo•ntrutas. t ycnera a c rot Ne eysbm tl.-by. PROPOSED -I II.Yiabr testvy.Seal tw:l!ill lanX nIN wbr to oath[YN.rt r LOOD MAP DATA PRIVAT hELL --- -f I ---------- 1. cvdbn,Ict craw la 24 M,•f.Rc1111 No tank!°rro evtict by vThe elecVket j-nctlm tnx s�i,g Ve pump+aster sro °eta MAF e;3 E:01/265H - -_ _______---_ _ r 5P' PALE 6ROHH ter lk 2<-Mv perbes compete.Let tte talk stow Iv v e oust m wotarelMt oro 1o.°eee Im Ne UA OwrS tale hv..mr. MAP DATE:Oq/_5/2009 ____ __ F aoaaiebrot 10-tcv p°rbm.Tx tout's opprwee II wtar bvel s FLOOD ZONES% E(.m j/. ,, ,' INE SAaG ro tl Iw role IL'-,cur p�xr otl.Hblar pr..aura harry H 3 Ary blou.w1 Iamb.arts..N tx:A Ol-i wrl mot be pbcetl PROP.RELOCATION OF r.comlwrrac.b m omlb dbr ratalb[bn. on m pa0 fcmcr.te.Plmtk a°Imrgbeal ow hove a swneprod •+.$1T=PROTECTION/GILT FENC.NG TO BE WATER SUPPLY LINE TO _____ u_____________ _ 13.ISc k!at mow«wort aw 1 abcl el was-corm vc ____ -` -oral... ercle.ure coma. INSTALLED A<REQUIRED BY THE TOM OF gEAR YARD HOSE BIB \\1 " �7 rViS EpIGOUNTEFSD tg9'6ELOW a p rant Iccotkm d eorJl aueaa opcn.ly b.an s.a1 pwnps on root V - F A- mate. I W e m«mesble on awulmobm ___ ____________ -E_ .a trot-.weer.- evk"Py be•d.- Iran«c_ cocas'p. ees nu.s FROP,RELOCATION 0=EXIST- _ ___h _____ (..�_ ro 3._Ufa_ WATERS DR WETLANDS ARE NOT W.12'I-S-ORY WD. - I A TAAK T. t 4.h<troop mall m et!«roc b c Sc•a.,t 40 P/G Itd Vee _ LOLATEG WITI::N 3^v0'OF THE PROPERTY. (!]2'FEI6HTr(CRY BLG6J 1_ __ ___I________ �\- Z I, ueb prclmkcbe Ftk ta,:ka srou canlvrr.b rro vvacllrot W ramou`o ly cc rm er°}sN<re.ne.leers -- -a-Z Mbaa[Kroi Iesmat'w or Fl re oro`ncchaicol Glkbl• t«roc C: 4,E:-EVATICty REFERENLE NIVD 1955 _ J - (IAWKJ'Am<rkw I:.rael Stage.la PrelawKaleo Fs lK 5,Te Ge e ' -- ci0 O F FrrlmeH Ya11 eexrve x rro ubm epeneb N-eI.0 • -'�.Y�L 1 TonU'AA51 ZI000-2fiOt mo ore opplkeble revbknapa.fes. .rermel eoeretWg tic e. - 5.ANY VISIBLE N 15.-O F.E-ECTD hELLS, NIN. LOC R LINES ISO'OF S..BJCCT /' ')' 1 �5• 3.Nbn-ewweb tales ro I x factvu mael.bleo v m-ambles 6.lnpectier Ior takooe err Ve rcrce err.1Jthas hill t<mme F ANIL RTY LINE$ARE DEPIO-ED ON SITE - I -10-)O-] the Itw/e15G�Im I«'ry by o mrtH°b°repreeentaeve d tz H tra Ne p,.,n test p:eceoma. PLAN. � -�---___p \� 9.Each tW shed ba[...Pled a ero mavlxwer nIN IN, b.ANY EXLTING SAN.-ARY 5•'STEMS FROVDE STAIRS TO ACCESS REAR rwmr.cwer w+b w'age,c.pa�iy ad narl»r d opvnrya aw _COATED WITH'N 15O'OF CIBLIEGT / YARD;TBD 51ZE/COUNT IN FIELD 1•�'- 'T`•---0Y- c EATIOO TOE6E- mb rwvl«wee,pe•eorontgy malletl of Ne Wbl ero d tb tvs -ROFERTY LINES ARE D PIGTED ON SITE PROP,4'x0'POOL EQVIP.PLACED 4.All wna.Moen,rods,w.e« ...wen..1.watt an applbtl / NIN.:5 FROM SIDE YARD E(,a lot°of 900 pcmm per sgcve 1-1:psN. T.PROPOSED SEFTIL SYSTEM OE516N INTENDS PQOPER'TY LINE;PROVIDE BuwED I50' �� ?e' PROJECT: TO AVOID THE REMOVAL GF ANY EXISTING / I / w CXIST\RCTA NINO WALLS S.Prot..t cowrcta town era riera we rol permlt[ca on TREES.THE PLACEHL=NT OF SYSTEM ELECRIO WIRES^QOM E%15T'NG D nomcowcte rooks otter otwrnlse opprwee bg tom ma+«eww. DWELL NS I J / w' E(_a ` THAT ALL RE MAY BE INI U ED PROVIDED 6.Whcrorw pr«:loot,ran-cwcres I/A owR!x ahail THAT ALL REQUIRED TALL 1M SE-BALKS / 1 5 ' y p_/ �; __ _ ,_ p M O LTZ rot be lecotoo nINW grorw.a<r,=m•Inbhotbna Not Pr°o bxc° ARE MAINTAIyED.'NSTALLE¢-O CONTACT FRS ,NIN. N u( ,� E\IST. '-_E``` `f(� -IPA Fr. ~AIS PER NY5 r.1Nn vu w.ntar pwtlula mre mot m ratan or.g Imt ebn. ARCH-ELT:F RELGGATIGN OR RETAINING WALL I rG bp I TRE-S I •3 POOL G°D1 SEPTIC ..rig.aw b«k(:IIvy b prevent...logo b to+u I.a b,ow a1 REORIENTATION OF COMPONENTS REQUIRED. 1 I f 5' taker aMuw m cob lNe mom✓«rarer�npletoN m>embloe.I•. ('o f NIA.I R - be troll ba saolwcc ntu s+ail [d��t_s1Nb[ws B.EXST NO CONTOJR L NE5 HAVE BEEN EXIST.SHED TO ' tl % :.'-STR•'.-EL=3235' EL_.g/, PEBRUPRY O'•.30]a Fe>be iv nebr tba3re»dmr":>feibtbr s»n a emtroe Ai'PROXIMATED BASED ON SIA2✓=YGR BE RELGCATG I I k to-_ - t•�.=R, e -- i \ >pecnto dy Ne mmN«wer wer cpprovem tsy 4 DePartnerL _SOT=v-.OF-AND 5 iE 1 i 1E[=3�1 TesT acLL al eA-A 1600 ALVAHS LANE OBSERVATIONS.CGTRRAGTCR TO VJF. RE,.ATIVE SLOPE OF EXXISTIN6 GRADE AND EX'S.VE:LL AS FROPOSED ' c ' (DRY eLD6-: 'L.em s4' ?• NCGGAALD 6EOSERV CBS err.ta.!>ere"mbnetl h wolno-.abr,qw m>y- -e BE ABANDONED LNOER---C Lam'-=� < I \ PGB I-�e CUTCHOGUE,NY 11935 pro/e>abrnl Yal1 autrnt Iveyar�.rcicvla:kma tc prove lb do,t CONTACT AROFITEOT F CEEERVED MIN. LrNB '_ O, 1 SCLTNGLD,AY IlaTl SCDFS REF.No.R-3G-GOOF �r of B•e tat(niN w..Y•wt wc,aha cr N<omRbr el mlleaU.11 515NIFICMTLY DIFFERENT THAN SHOWN'. PROP."'xT'HOT - i T- I EXIST. o (631;TE$-56TT 3 eWws ma-e vm erti-Is.,er Ne nata e'ep1«ee. - iVB WITH N PROP. ^� T ASFNALT 0 \ MCD6COa6NAl_COM Tt•o b'•P'!oPY rnKodwa rc l m ocro my Iuglns[ RATH. EGK VE TO axpe.btl/ro.ame aelma.,atw e.wpewn rqh Ne[mN,empty.sm' I = ' \N� I DRAWING TITLE: MOD IF ED x .wer w cop al rro Eo+laJ a,a1 rd..aomwewe wtnz \ / !Y AT Ea:G,.p,; a ,\ LL-BgS' NOTES mtermnay tb olnwt N mc•+orro w Uotlmt nelght requlno 1 1` . ♦ 09 OL DARK Ell LOAM 7 TZELccnr_v oltrvcojj(lsroa-+ER uPOA ` I 1 �I NIN, 'c• �AG,wr GROW:cLAm SITE INFORMATION DECK DRAINING TOf3'a DR'Y.ELL W 1 1 1 - - I MIN'\ - 1 LOT u\ I SAkD TRAFFIC-6EP�ING COVER a TOP {--_- -- - -- I 21 - SITE PLAN 15/ EX -HIGH FENCE AS OD MIN. 5UFFCLK GOLNTY HEALTH D M R EFA-RT =NT APPCV AL PER-1 POOL CODE 4 I e N 1 H.S. REFERENCE NO.: R-24-10,53 �' I I 4 I PAGE: WELL AND LATERAL MUST BE 1 ( WD.FR �' . t5° ��� S P-101.00 SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES / / Da`LL1NG r:/ LtwE OF M N°LTO'H!J SHOWN ON FINAL SURVEY I ' I BASEMEN-' I F`T °e ' PERMIT FOR APPROVAL OF CONSTRUCTION FORA I cRAhLSPACE I� \',.9p Etas+N OIB SINGLE FAMILY RESIDENCE ONLY Abandonment of the existi EXIST.&,RIEG ' '4 eEDRGGNS, ng sanitary system must be in GEMS LINEF.F.EL.•3T. ......:n" with the DepartmenCs requirements. LE BR°w*:=11� Z' 1 K ' I I sa+ mD-ARSE sAlm DATE:09/OS/24 1 OF 2 Submit lnmpleted form WWM-080 dsprae/ DRAN4_ 5•'STEM INSTALLATION NOTES SeTSrNT' DATE 9J17 20Z4 A MINIM M IG SEPARATION IS RCOU RED BCThCCN ORYW[_L5! I +I I EXIST.GC/EZ7 hS 6Y•M1 L,MIN t I LINE OF 50' H.S-REF NO. R-241073 WATER SERV CE LINE.UKDEROROUND UTI-ITY LINES,SEFTIL Ct r,- CONP°tgNTS.LEACHING FIELDS.SChER COMPONENTS.OTHER I I OI I i 1 PORGi 1 I D l_G Otn`5' i 1 "IM1.DISTANCE YTO L APPROVED •Jp/.�' (MIN.DISTANCE TC Q FOR MAXIMUM OF 4 BEDROOMS EV3N=EFT Ct• kC,0,REOJREC DRYhELLS AAG THE EDGE G=ALL FED 3= ,ZE WALLS - I I I SANITARY LINE) O • A MINIFMM 5'_CPARATION IS REGUIRID 3C-WQA DR•'hJ_i5! As P E Oo R A.CEPTIIILAT'l PROPE RTY LINES n l di 1 I I EXPIRES THREE YEARS FROM DATE OF APPROVAL S A M1NIMVM 20 SEPARATION IS REQUIRED�TWEEN DRYFIE_u AND I 1 I j,� EN15r. K5 m gED -L'P INS c,-U1MN+AkC CUNSiHu:rbN BURIED PROPANE FUEL TANKS, i 0•I _WELL EXST I 0[Ta avia A MINIMUM 2'VERTICA_SEPARAT ON 15 REQUIRED BE_T %TIE ty ,_ I SLATE 1 / I Io pNy dN ,P Loa F1A=t APaNuvat Js F�Pv WWM-073 BOTTOM.OF Ol-eELLS I THE HIGNCST EXPECTED GROUNOWIT_Q 1 \ ', h'LK I I M1 ! ELEVATION. LLi: I ? ! O • OONNECT ALL GUTTER LE Rs TO NEAREST DR•lNELL �!II'I SEE ALSO GE-AIL ON CONSTRICTION DGCJMENK \ \_ _ --- 1 w E T. ILITY POLE I A<T'CB'4G"h / '2.GC2' ' COMMENTS:N0 6RC.luDWATER •1< _ E, DRAINAGE 5•'STEN GA_GUL ATIONSI ` �L?55 bq'-v _____________ EKCLATERED. 71• 037d D5 POOL VOLIJh,E=IT3-5 S.F.;GROSS-SCCTIGNAL AREA;.IH F-=13PG A L,T. \ \P -- - ____ �-_-- / �OF N£K /� POOL DRAINAGE REO.D=5%X/OLUME=5%x 131G 4 OF =bP52 C=. EL T9 SEE /`1TTA C H M E N T�S� TOTAL STORAGE VOLUME REG.V=69 5r_L F \ A L / A A N EXIST.L-IUTY POLE .. ()g e DRYNELL PROJIDES 42.22 L.F.PER F-.OF DEPTH SITE PLAN / ()Ben N 2'DEEP DIN.PROPOSED-b444 F ST QA6 PROVIDE. ECALEI 20-0" �q�t'REh�z ILn OM5 a SEPi GL•+SSALLALOV 5'�ARDS, V � '6'� � "ll y� �-�-�_ 54T'25'2p•E A6RILLLTLRAL I.M nto.ar m.•t re tl e crre,t L qv a Mbste Licerne purouat:0 1 n[all I/A OWTS twks p t x>mcaonq to maMaeturer's PLAN IJOTE5 LANe 'GOOO' $Nio k Lovntu L v rlfnopter 563 Art c e Vg(Sept'MusVy FFP-anmtbre:uM1'a cc g to these abndord A 9 yUg,EG-PROPERTY � I.�P���OOO TTT L 1. �; Bve ne>-s)tlrouar 4 Svrfo k county Oepatment et Labor �P'cabe recomrorcbtbn mow:M1c xnufmturer sMt m ♦ 1 G VE_ JRDOF A5 REO'D OWiS. PROF,NEIGHBC¢ING L ccnsro ma Lo•i>mnr Alla n.pKsuw[.o SWIo k�Lo Lam :rplementetl ' I CL g 563-T9 M ve o men[of Labs Lkaro oM r Altars \ � t PRl.P.20'm I'OI.YLdC D STR eUT10N EO%rSAMPLIN6=OIM); HELL UNDER SLOWS Q meNtaM o tit a•Ikereea/AOw'S Mo'nteroroe Prw sere 2 M I/A OWiS eak a-plc tak e,a l rro wstcl ea of level In al . C REF.NO.R-?O-GOD Ncatbro W o mwNvm:to aaee,ray tltreetbn of./oro q4 - .g SEPA MAINTAIN 2 M N SEPI.RAT ON F¢OM VA OYrS a 5'MIN. I I 2.All/A OWTS rw>t oe rea's.ered wh Ne De aYment N e N m o mFwxm 8-rcM1 Hka me d SEPARATION FROM LE4LNME POCIS P 9°ester K proper y bvcbd oro ortlmce w h Art cle 9 0°LM SAIo k County Sewtov Gotle compacted Barb(Irce Irom relies)er pea aweje v���• y PROP.m O_IEAA ALARM/CONTROL PANEL a PJJ¢SO 1 pr or to tM Depatmcn;yont'na certll catbn of -PIA- y +®� "Y1 � C ELEGTR LAL LINE FROM'/A 0W I I I J f0 roWCNon on•m bu t'pure 3 /A OWLS Tanks sb m o•wma wth PROPOSED HIM.4'-O' M e s V wtbn my/mmho a or d iV but on Ieachng 5lrveturo may m } ®_ �.t �� ,,,(((yyy� 4F'"Sy. �4 PROP FUJ MAG PIR BLOWER a 3•e NL A R LINE TO H 6H FENCE AS PER NYS t 5.M cxccutm Opc•atkn oro Fbintcror4o Gontrmt between tM rewired for all aystcrre will.myltple oech'.nq strxturo>enless m / 1`- R es,j^j " /A.h (PR MANU.SPEL.5) POOL CODE rx •c MaNtenorcc Frw'dcr md=roper4.o ror rwal m xbmated o tM a rnetNe tlasly b cpprwatl bu lro Deoa-[root. !• IIIIL�' f (� C%IST.SEPLIL SYoTCM TO BE ABANOCt PLR B vepatment prbr!o aop-oval ci tFe"A OWiS ragiaVatbn by Ve (� M �a1 U -.S STANDAROs I I O Department h accoroorcc wrh Artkle 19 0l Lb SAlalk Loulty 4,All w[leb from eha septik ant most m awlded wlh on Ib' >,1 � T- ��`i C N I -O O Sa+Itay Gotic. aop T'a ogvtralcnt apprwco ro Rc eaYro:r,g into lb I/S oI ���T,� VVV 6 PROP.CLEAN-OUL.INSTALL MTRN O'0=E-S.FLV1G. y } lro s PPtk Loa ik1WC deotn.Cos eeflect'en mrllee ae �jq ry Z All Mtolictl 1.OWrS ac reel rco n Fwc m InRbl 5-vcar reco ended for Mtallotbn m ow eccF e•flxnt aop T. � ��� _a� �•� y I I O C N O warmly oro operatbr/mointcrencc-rvke aonVoct.Al:cr rro 9YI I SITE CATGUT NOTES: d W^y In bI 5_yea eperotbn ob roininaroe service conlrmt het 5.M top of he 114 OWTS link or scoot tmL e 1 not be lacatetl � �, � (A♦T' � I. TH.S S AN ARGHITEGT'S SITE PLAN d IS T U explrcq property owner ore ex�acled eo mointaN an oporo:Ion greater tron 25 Ice[or Ic»roar ac foot below Ilnol arum. � sy/4. a'•i8 ti'R91 L.-IT]� 5JBJELT TO VERIe ILATION BY A LICENSED X >N art mo.neenanm eorum:'r me ooroo with Artieb 19 or tM J� a y\L I co 20 RVEYO SUR. THE INFORMATION O Svllolk LeuMy AS all Sm1lery Lom. b. o mintm.m, conplNg-1..lea en1rove -KM1 vered 1 � A(r / m O y M A ���!!\!!�{ �•� 1 REPR06 =='D ON THIS SITE PLAN IS TO THE O L N s openNgs to yam beatee over tM H el oro outlet. \ 5 Wtcn m I/A OATS reoirea a veto.Uc omit aholl be vented to the ewes II m either 20-KM1 eknctcr watert'ymaro S ® 'S O ARCHITECTS BEST OF KNOWLEDGE. N root or or re>imrae achy-rvctl.Vent plpca still cxtero o Mcc:prool lockho cos:trm mvcro a Merino tk cwera o< r.Y, ')' q O^ min M b Kroe abovo lie root I'ro and lies top or tM von: line)yade.All coven atoll m m�yce h eccaremm with secum �`� `�� 4/ t �a.�11 I OS/S I / "-'.SURVEY II.FORMATION WAS OBTAINED a a O smll hwc o mNNun M1o•i:mtal xpmotbn of v Iroroa to tb III of hb stabero. y/� '.i �Dil 'y aFx L:IT.O I FROM A SURVEY DATED APRIL 05.2024, sloped Portion of tb root.1,cases wM1ere It is not Praeekal to a .3+v MOST RECENTLY REVISED JUKE 26,2024, wL tM oystem w the•es de,ce root,a vent p Ne rro,be piped m T.W,m sampling maNe as arc apprwce m tx Mtalloe H a I Fr��q I /r AND GREPARED BY: e exterbr al here> a and terminate m m o IE NaMe drlYeway ar pinking M mmM a>roll m tlm�ed e m LOGATI ON MAP o amva gatle and ae bin: fooe r.orr property Il,ws.Tne>e vert Vorlle.;.g to meet[Fe ragvt._e or AASNTO H-2O or k 1 YOUNG ASSOCIATES p pcs II m locotad o mrlmm of s Icct lrem ary window a IE-2O Iamlrg. SCALE;NT5 I I / FOO OSTRAI DER AVEN.E L mot icrmrcte w to o emmn 11 to dwim All vcrt pipes n t Pave o mhlran olorete•e,2 rapes. E M a.t et invert eleveekn sro m c m r mar of O l Imt RIVERFEAD,NY 119GI Hro N.bt Mat al- r} �-:' - 1 TELEFHGN'E:(631%T2T-253 a.Nneeiletbn ad me dl he vA oh-5 mne aeMmm to u PRO-fEGTY=ZONlt.6 DATA .- / Depmtments eppr w ooummt prepaeo h c,Som,p to meshes I owe m re m oometer d:lee[a m I I EMAIL weo/A 0- ADMINOYGUNGENGINEERING.CGN m .,h Me>taroac•for Apprwol-I �ment of Im eo or 2 teat b:2 root_ TAX NAF awn 1000-C2-G4-H.I IrmwotNe ores Ate•rotNe e,s tc Ymcwotor Traotment Syteno.- I Ie.here>roll m c moximmr rctm!'or mplh mow the outlet Invert U MNwuNCEssNRFauRFNFnT=. ccvotm of ax Krm ZONING DI511ZI AG NONCONFORMING I / D .VA OwrS a-p>�k teas art be coretrvcted or Prem>e A r p4.perou r,Hera somprrg mmhele a 1 bo J'� emerote.lumrg aep.�thyk;ro,polFropyero lMrmop meka,m wa4,rnq,e 'LOT o I �� W rtlror muter o s n m wIV Dcpat�M�stimaaras art - -» - K oNYCRR A,dpeMxTSA rro or aeee prohb eae E_ELT_ROLL REWIRE--m SOIITHO DD 70WN GODS CSEG ION-ABC t24)." _ •- 2 Wan an I/A OnF_reavres a-po,link la protroatroM it. LLATROL P4F=_LS 3 Z A6RILULTI�RAL ALSLST 31 2024 septic toes sMl m oeaigree i,accoraoroe wIM-ctkro S OI .M cmuol paro box inn:m p aced owbe m a sureties DESCRIPTION(FOOTPRINT) AREA L:O%VL¢OATGE Y 0 D I I LAND art 5-109 0•Ma a•.a+mro. pedes 'roes the ebvctvre hat t serves.A:tematively,the porol EXIST.EXTERIOR HOSE TEST HOLE a2 DATA 5.Unless ohorwbe specs•lea,�ro IeocN mx may m mounted on m-s-oval of he sructlmo(preferable TOTAL LOT AREA 42,9T6 S.F. `\ N y BIB w/WATER SUPPLY �' 1 MLDONALD 6EOSE¢V.LES ng structure/>ystem tMt a[truly room,mtl rot c R rc>P-.).-F,Iocc:Ions Im ma.nurg ` -th'N LINE CONNECTED TO FOB 125H L- follows m 1/A OMS chat m eeslcrod In mccraaroe wlh-ct'a Mr Parol tax will be corelmreo w ties DepatmcM m a \ B I THIS=I%-ERE ONLY I 5-IOT arse sues or Mb eabma. ty-cmo bmis art win.I/A onTS marafmvcr approval. EXISTING DWELLING 1,113 S.F. 2.6% \ 1 %0` / SGVTHGLD,NY 19T l _ _---------------/-- __ 1 (63U 165-36", //•t 4.At a mintntre dll I/A OATS heM t to-a-p[k tints obit 2.M rmrre of he I/A OWTS O.M erw'der+list be clemly ---_ MLDGEO.GMAILOOM •V/ bve 2I-covered mA_o to lro mntIfto on tM Msbc or eM EXISTING COVERED PORCH IHI SF. 0.4% N _pe0 yam located over Pao ad Klum a prom rumba `\ NOTE CHANGEIST I .�' EL=IA• l.L Iola[mtl outlet.Govae chat m clMer 20-hch I,IFpIaf wotert'dn: to concoct h tine d atom. EXISTING STEPS FROM DWELLING `\ 1 !L=IeH' ae 1 q Print l=toes:'rm cworo a hermoplmtk cwen 3a S= O.I% 1 EXIST.-STRY Y.D. Q o<IMaI Ail covere as cnvrroys/rlsera atoll m msi d N 3.Eztcrbr t cw a the> to -rvkatl at (TOWARDS CRVEWAY) \ FR.BUILDING DARK BROWN LOAM ymc. gro parol placeme, ys:em /' accordmm wlh aecticn 5-III or his atoMatl. art time,elNnlnatNg tM bee:c mccas Me irolm o1 tb Wlldinq. `\ �' DECKS(DRY BLDG) ID' a.ita�mot box mot m wMN vlaw o•:ro system location to help EXISTING ACCESSORY 6A¢AGE 352 S.F. O.B% `\_ 5.W a I/A OW a a scptY tat b oF,r to W Installed N BROM4'1 HILTY SANG drNcwdy a pmkllg aces,Ma Wt sroll m msloroC ad/c. WI Mranm to wihetad I-5-2O a I-2O looehg ae'mslgnated by 5-M cmtrolrparol sin I mopes a at o cemlatmle MIgM la EXISTING TRELLIS I56 S.F. 0.4% - TH GRAVEL AASMO. access N ac dance w'tn F raI Ero•aacy Moroacmcnt Ageru, PRG T WE O 3E Irrigation Well EXISTING 5•ED' \` 6.6abogeroy�mro still rot m pe,mtae when on VA OWLS b m 'V floao:oro requvcro,es. (TO BE RELOCATED) 101 S.F. 02% 1DONED'. PL1i1� 5' M N. I utilized d-wage d'somal. 6.M roll meet Notbrol Elccukol Mmufmwen SGOHS REF'NO. pmel s EXISTING SHED R-20-0006 I _ 1. IG ccl'I-(MLMuy ax specllketkrn. (TO REMAIN; 702 S.F.' .696 Peas MIN, 'IN. T,water softerore s,ou roe diecham wo m VA OWLS ae tM .� IG ve cement rommmeroe wain.aaR�ror mab.mh m aar,neaeao m rvr ebaMlael as 50'MIN MIN--i � r.All mlRw arodc wwno must m «lilt.M E P.` muwcll mceoteb'e m To-or Village a,nar.R canmlt mot Feve tomes as mobwe EXISTING WV.FR.BLDG.w/DECKS IFS S.F. CS% _ PRO. 5'epprepr ate sea s m p•ever. Depatmente. Iran reochho the control Po•el a.'ImcUa,6oxea. PROPOSED RACED DECK w/HAT 1 I P F.4E SAXP H.I/A OhTS tale I seplk tmb Nun be wateMlcht oro B.Emh s_tl stall m equppeo wih a furctbnW warnM eustem. TUB a OUTDOOR SHOWER 2B3 S.F. G?% TEST FINE`cAw o.... of eu.ra arc Aot. moterbb trot lie rot xbbet!o w•Yh wnl octMo[e aolTle oro't..1 ales-Wok cm be reoalW I I VALE a2 PRO c ' exms>Me comoabn m mew. xen art Mae by tM occupmts o1 tiro W'leio servee.M PROPOSED Ih6RDUt.'D POOL 64H S IS% Deaatront-ta'a-ateleneVy mvke ti MtP..to Ex ST. 1 _y--J--------- L.F.2 1 9.All[etas met be woteM'yt.Two metMdf of ensurlrrq Lints ae prwbe Nmedbte remote atom ro:laica;im to Me OeM provimr 5T ^ w --_---- woeertlejlt shall t»either vmv m teat'r,g m water pressure tesUr,g covered the 06M oa-eemert. TOTAL AREA OF ALL STRUCTURES 3.T65 S.F' H.H% GCKADE FENCE z - me[MM m I011aws, � W/WIRE MESH;FENCE GOMPLIE5 AS PER NYS lo.vmwm tesih.Sea'oro a .ink one to lour �e�sorm e�which oro rot dmlyed to Ilow bE arwlty ore MAXIMUM LOT COVERAGE ALLOInED:20% FOOL CODE ' -___ -- I r--------------- Yp-:• apply a vocu.m Mee to be e'u'ppm x/t,o cmt•cl parol with rreae el PROPOSED (4)KMz(IOOmru or rorovrd.M•onk b cpproved 11 90%of carv:ectNq a portable jer:erotor.operate he ep-bYhg a DWELLING W vmavm b-1 for Nvo m'Yulea. power age. FROPOSED - J 195 ll.Water testrg:Scot tmc�rill Lana wN ovule1 to outlet arvcM v -L. A I.FLOOD MAP DATA: PRIVATE ILLI__ r I K _,-- O F(-�-1 elevotlm,let start Im 24 ron.Q,fIII uc link to eM ounce zlvert I.M electrkol Jaau'm box>aving lie pump motor oro naoe> HAP a;36,03G0165H �' v WATER IN aner tic 2aJuur perbo b carp'.-Let the tmk etmd la a rust m watertlght orb Imated owlet tiro I/A O link crommr. MAP DATE:09/25/2009 ____-F---rA--------------- `�F oddrcbrol IO-Neva perbd.fro tint b apprwce If wine.Ievei''s FLOOD ZONE:% I w PALL [roll fa tM IO-hour perm.Ybter pressure teatNg b e 2.Ay blowero located euts'tle o!rro/A Ow[S unit must to placed PROP.RELOCATION OF 1__-I H ------ opt, F NE SAND ` rocommor,md to m done obit.after Mtalldtbn. m e pad(cmcretc,p-tk a flmrgloss)and hwc a e proof 2.SITE P¢OTECTIOW51LT FENCING TO BE WATER SUPPLY LINE TO ____- m----- D.S link rvufectrers s,eil provim a Imes of ron-corrosv ewimure cwen. INSTALLED AS REQUIRED BY THE TOKN OF REAR YARD HOSE BIB 1 F`=�7.1 COMMENTS,SROADw4TER _ I moterbl N a p,t I Aotton of eobr occ<v opon 9 to wan pumps oM.loin SOUTHOLD. _______ _______ F(.a L¢Arx 3.All Vccs mot m mcersiblc oM ecrviccmle _ `_ ENCOUNTERED 195'HELOW I Mat'anhaeo Into link nay m fold'. from mcaes openNz. PROP,RELOCATION CP EXIST. - ` S.SURFACE WATERS 0R WETLAND^ARE NOT 5'x12'1-5-CRY WD.= SHED --- 2F I %uc 1 I 4.M 111—troll be oltmheo to 0 5tro tO PVC(loot tree LOCATED NIT N'300'OF TFE PROPERTY. I - - trot cm m emit,remuvco la a '.or}sareM.The'teats (r22'FEIGWI,(CRY BLDGJ _____ ____i________PROP._ b -__ 1 :Z I.N .,I arete prelo too eeplk taros Noll 1,—to the soon rot m ettaZhco L^eha Ic•cc moH. 4.ELEVATIONS REFERENCE NAND Nee -_� - '+�-_ bCCL Interrutierol A•smrat'er of P b'rc ma Mere,a,kol 011klab POOL -- �9• (IAPMAO)'Arrorlcon Notaal Sto,o".la Prof -ted 5eptic 5.M Ton.. on, Dep artmert atoll aescrve tM oma syetem operate MrcugF AN51 ZI000-2001 cro cpplktlsle revlslmsAPmtes. c rortnal perotlno cuae, 5.ANY VISIBLE SELLS,OR PROPOSED WELLS, LOCATED WITHIN 150'OF 5.E..'EGT �' NIN I '1. 2.Non-coracle tank-s ao�l m foctvy osscr.blco a mseirblee In 6Anpeclior for leokooe or Hie(tree rah fttings will W mace FRGFERTY LINE5 ARE DEPICTED ON SITE tlro fiele/dbtrLLwtbn 1.1I'ty by a mrtFbd repro-n__of tM aurlrg tM pmp test proceMre. 6.ANY EXISTING SANITARY 5`r5",EM5 PROViOE STAIRS TO ACCESS REAR - 9.Each Lowe aMI m ken:nieo a the mmulmturer wiM Me EXIST.bRWEWAY maufmtlrer come a Io .rmber W o LOCATED WITH'�N 150'OF 5L5,ECT _ YARD;MD SIZE/COIg4T IN FIELD 2 z.PATIO TO 6E� F' PROPERTY LINES ARE D=PICTED ON 91rE / - T d ( ¢ go,copactzl me PP,ne"art 1 r- _9- ui sate mm,lmeurea,pe•,ronen:Iy merino ee eM wee eM or oro eaa. _- PLAN. /� -•• REMOVEQ t c 4.All walls.Iloore,roofs,mo meets cwen shop rmbt m applbe PROP.4'xH'POOL ELtUIP.PEALED I-or Sb0 lee[(>I. ," L.=30.46" po,mes per>qc p ) �,PROPOSED SEPTIC SYSTEM DESIGN INTENDS MIN.i5'FROM SIDE YARD F(e` 5.Precast coraretc cwcre cKt r:eero ae ro TO AVOID TIE REMOVAL OF ANY EXISTING /, PROPERTY LIME;PROVIDE BURIED I ISA' a \ �H• ` PROJECT: t permitted on TREES.THE PLACEMENT OF SYSTEM, CLECTRIC WIRES aROM EXISTING ! i p / EXIST�ETAINING WALLS ron-corvreto talks,n!ess of crnbe opprwm by tee mvu•ocurer. COMPONENTS MAY BE AD-LISTED PROVIDED /� CWELLING II i 0 p / 01 F( . b.Waravcr prm:kal,ror.corcre-c I/A OWT9 a-Pelt tarts Noll THAT ALL REQUIRED MININWM SEBAGKS Ki M 0 LTZ roe m bceted.1-yoabwafsr-Fa 1b 11otlore-1 ao plawd ARE MAINTAWED.4157ALLE¢TO CONTACT I MIN.I ID u( ZI -- �- 6 PROPOSED N.IN.4'-0' wIMN oulnwaeer,pa:kvla care mast m token O.r Mtollotbn ARCH TECT Ir RELOCATION OR PROP, /•z Ex15T. `F(a HIGH FENCFFF AS PLR NYS SEPTIC mda y and mckl:Iling to prevent .-So to fame wnaai�b,me o'l REORIENTATION OF LOMPOxENTS REQUIRED. RETAINING WALL I I 2 f 5' qol TRELL'S -` 3 POOL LODE\ tmksub be sole by Me movaeturer completely meomblotl.If, = MIN. KI 1 I——or size,t'ne to"!a dell,a"d to the alto In a..111,,all H.EXISTING CONTOUR LINES HAVE BEEN EXIST.SHED TO I lt� T.-STR".:EL�32]5' F(e JoNts still m-oleo wIh wairtlot,t gasket All.mks srol m APPROXIMATED BASED ON SLRVYOR BE RELOCATED i I jL to t WD.=R. - •j/•� \\ FEBRUARY 01.2024 reeled la water tM.Ves>offer ,pp,elm ustra o method '- ePecifbd ay lie moNmWer ad opprovea G Cue De Fm rt. SPOT ELEVATION AND 5'.-T 1 I-1 r--- GARAGE w/ `_ 1 CB_ERVATIGV5.CONTRACTOR TO V.IF. ,•LAB 5 M N' F(a TEST HALL al DA-4 1600 ALVAHS LANE T.Incmn weer teas me»toned h.aou-awoke.,U•e melon RELATIVE SLOP=OF EXISTING GRADE AAD EXIST.YvLL AS PROPOSED i I (CRY BLDGJ EL•a2 qq 9�' MCGCNALD GEGSERV CE5 prafaskrol shall sibs[lveyacu eeleula:kro to prove ere•.e'eht CONTACT ARLIITEGT IF GESERVED TG BE AEANDONED U1.DER-0 L=L1-J� NIN LAB EL=P \ PGB I_^5H CUTCHOGUE,NY 11935 of Me tdrk(wlM or w't^wt orcb%Iro a lid maubn al bolloaU.II SIGNIFILAN'TLY DIFFERENT THAN EHOFIN. SLDH5 REr.NO.R-2e-ccce PROP T'xT'HOT - L _ �--r/-___l EXIST. U 1 S(UTHOLD,NY 119TI m at lemt IS throe m�a than the. "t oI-water dbpbcee. M buoyaey caleulatbro sha'I Pe mro v 1l hio clt TUB WITHIN F DECK l T \ \ ASPHALT V (631)-165-36T1 expocted/recoroed aounowater elevotlon wiM rho talk empty.Sorg ¢AIS�i D=CK -�� i \ 1G DRIVE TO I \ MCDGEOaGNAI_.LOM o^top or tro emk(e)oral:rue m aurobared when - \ l dN u=9s5 DRAWING TITLE: j detemunNg tM onuart of ora,a%a m ballast weloht raqutreo. T \ MODIFED X I NOTES RELOCAT-_D OUTDOOO��SFOWER UPON I \ I I 11 5 10,ONN I \ O,, OL DARK BROWN LOAM DECK MAIN T03'O DR`ILL w/ 1 \ I MIN r ) MIN.\ VACANT EROVN GLAYC SITE INFORMATION TRAFFIL-BEARING LOVER a TOP _ - -- r----- ----- LOT `\ 2O' 5A� SITE PLAN iS/ p$T 5• 5UFFOLK COUNTY HEALTH DEPAzRTMENT APPROVAL Ex T.aNYS P FENCE AS 1 \ PER NYS POOL CODE 4 I b MIN. H REFERENCE NO.: R-24-108 1�3 /- I I I EXI ST.2-STR_. `I K PAGE: SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES WELL AND LATERAL MUST BE I ( ems`--°SING e I I I Ll,,, 15H,.c�A`vp `\` F LL 1 SHOWN ON FINAL SURVEY °FRD VCE TO P PERfdR FOR APPROVAL OF CONSTRUCTION FORA 1 EXIST.BLRIED 1 I l I 4 eEDR-�ccNs; SW I M1N C`gTA • -101.00 SINGLE FAMILY RESIDENCE ONLY 1 phandonment of the exi ti to / / ' ' \ ,S s ng sani ry system must be In GAS LIVE I F.F.EL=3125' conformance with the Department's requirements. 1 1' �' �? I PALE taROWN=INE Submit mmpletedform WWM-0BOasproof DRANAF,Fa-,sTFMIN$TA_LAICVNOTES I I 13l ,1 1 I II TOGo4R5E5AIxO DATE:09/05/24 1 1OF2 A MINIM 10 SEPARATION 15 RCOU RED BCTY N DRYWCIS 6 L1)� EXIST.LOVE¢ED F 'SETBACK t DATE 9/17/2024 H.S.REF.No. R-24-1083 I G� LINE G E[MIN. I LIRE OF so- I WATER SERVILE LINE,UNDERGROUND UTILITY LINES,SEPTIC FORLM FROM APPROVED :der- -'L R� i COMPONENTS,LEACHING FIELDS,SCIR COMPONENTS,OTHER Ill 1 DIC-I OWT`a) I SETBA.'.K FROM ILL A DRYFELLS.AND THE EDGE O=ALL FGUNOATIOI,WALLS I I 0 $i '•I (MIN.DISTANCE TO �k FOR MAXIMUM OF 4 BEDROOM$ EMTINEEFF CERNTIrAT10l:REWIRED A MINIMUM 5'SCPARATION 15 RCOUIRCD 3C'11EM,DR•'WCLLS e I I I SANITARY LINE) O EXPIRES THREE YEARS FROM DATE OF APPROVAL SMVIT P.E.OR R.A.CERTIFICATION PROPERTY LINES A MINIMUM 20 SEPARATION 15 REQUIRED BETY.EEN DRYIE 5 AND I >W EXIST. TEST 0 FOR IN$14LlATIDN AND CONSTRUCTION BURIED PROPANE FUEL TANKS. UI WELL EX ST. HOLE el Of"owls A MINIMUM 2'VER RECURRED TICAL SEPARATION 15 REQUED BETWEEN THE "I I SLATE Id. FOR FINAL AppROVAL USE FORti WWM-073 BOTTOM Or DRYW'CLLS a THE HIGHEST CXFELTCD GROUNDWATER I\ ,\ I In Y•A-Y` Z ELEVATION. • CONNECT ALL GUTTER LEADERS TO KAREST DR•'hELL SEE ALSO DETAIL ON CONSTRUCTION GOCJMENTS I I\ " * ►El�ST..TILITY POLE\}I iN4T'GH'40'hGGMYE TSNO LRLL'kDw4TER ___________ 1O .�0'- ELCOUNTERED. 0374D �Y TOTOAL STGRAGEIVOLUME RED D v bR5T20L5F x 1390.4 G.F.=695G.4 L.r. �- 7�' {0 DRAINAGE SYSTEM LA'CULATIONS: POOL DRAINAGE V-0 -5%x VOLUME= 2 L`. \ \ 7 =3__ \ IST.LTILITY POLE / ��F NE� SEE ATTACHMENT(S) I A L vq s EX - (I)H O ORYAELL PROVIDES 4222 G.F.PLR F-.OF DEPTH S 1 TE PLAN \� J L A N G-1e 1 (U HO x 2'DEEP DA,PROPGSEO=H444 CF STORAGE FROVIDED SCALE: =20'-0" al��"eu'n aama,mn m.mnp m va swm a a voumn a srna noa n nc m+aa su"micwnan ua l9 omum sr,os»:¢a mor�nan ucm c w •m ru rn m s uRv m auew lA�ov[a wrn eot sw.svm's uo®sa sv vuai - �.(al�m,on� ' xa[ai swu Pu mr m n[mad�w",,K swrr a nasum•ra a xs awv m ria nrtr vwun."owa"dru wmer rxo um,+c asnmrta v®r.�m ra Misvpms>rv':Ew�oanmma a"e�rcam¢ua w,mrn a s�iasas'oa fsl,�'i¢�rwran o obis p?saue run lsrl w oas(0'1 v"�rmrn xc r�m rtn m�sm wnas um m ara®r 400 Ostrander Avenue,Riverhead,New York 11901 W.631.727.2305 fax.651.727.0144 odminago�uyngenglneering.com N HEALTH DEPARTMENT USE 4�i{►� �4C��+YC� Howard K Young,Lid Surveyor S Thomas 0.AolFert,Fl-ofe5slonal Eng(neer , f, Douglos E.Adams,Professional Engineer ]Daniel A.A over,Land Surveyor � � r _ S W E �6✓e� SITE DATA r F °^rye rO o A(,F4o AREA=42,976 SQ.FT. %UNDPROPER sscoHs SED WELL®o 0- ��o, sO(°/dij VERTICAL DATUM =NAVD(1988) REF.0 R-20-0006 a5,s Ce �0.�y.(�%• 2S• era P/o P UTILITIES SHOWN FROM MARK-OUT BY OTHERS. `e �OF % �. %:1� y+17M +17.59 ,TO h%}it, �9hrsJ Op, Ro an ,am Ex[S7I146 WELL AS PROPOSED TO BE ABANDONED +17.02 tea, UNDER SCDKS Q PET.#R-20-0006 3S• F]L ® �D ENGINEER'S_CERTIFICATION y 1ti a e�j "I HEREBY CERTIFY THAT THE WATER SUPPLY(S)AND/OR SEWAGE DISPOSAL % 20-$0 SYSTEM(S)FOR THIS PROJECT WERE DESIGNED BY ME OR UNDER MY DIRECTION.BASED UPON A CAREFUL AND THOROUGHS OIL, SITE AND GROUNDWATER CONDITIONS,ALL FAI pRmP@ CONFORM TO THE SUFFOLK COUNTY DEPARTMENT gs� OH s R� ;�� `\° CONSTRUCTION STANDARDSO IN EFFECT AS OF Q•5 - � J J y �o>, p qp °QyP �G i j �o�°aro �Q- ijKrmr�n 'G• v'l"'�_ S .���_d r I I HOWARD W.YOUNG,N.Y.S.L.S.NO.45893n O 61483 l +'s.m cG�h y° JW THOMAS C.WOLPERT,N.Y.S.P.E.NO.61483 A� _ Xal DOUGLAS E.ADAMS,N.Y.S.P.E.NO.80897 b se Ex[STING WELL® �G �° kd BEPROPOSED ADNDO titio 5URVEYOR'S CERTIFICATIO- UNDERSCDkS h 6• ,Q,c --A P3 RIF.0 R40-0006 ti / Sti .w �1 0�R 2 fit• •WE HEREBY CERTIFY TO KAV ITA AH LJ J A stogy THAT THIS SURVEY WAS PREPARED IN ACCORDAN p.�. -, aT �q�'�t�• PRACTICE FOR LAND SURVEYS AD TH OPTED BY E fO 5 OG < \ 2,� ASSOCIATION OF PROFE55IONAL LAND SUR O :, $ 3�.12 13P z 1A6, 4 G3 o. 10�& .s n �R tk 3225 ?sE fiYYR/S/L 1 'te a C 1019" e� es 9� `ezw ZS� 4589'S DANIELHOWAR W.YOUNG,LY ..S. NO. T71 �5\) ?a � DANIEL A.WEAVER,N.YS.L.S.N0.50771 .o-QQS 4o s J1.25 ,Rbo \ \ ,'0q. 24 •r* ,yob SURVEY FOR A ems;, tiA, �� Rti KAVITA AHUJA & DAVID MOLTZ LOT 11"MAP OF JONES WOODS" k° AS• at Cutchogue,Town of Southold '9 r �+° 6 �o° / LEGEND Suffolk County,New York RLF ��� `, CE a� CELLAR ENTRANCE BUILDING PERMIT SURVEY TEST HOLE �e°oar"0 `\ '9J1. IC°tom .' CH =CHIMNEY BY McDONALD 6EOSERVIGE3 4 AS rV y.� `` CLF =CHAIN LINK FENCE'R-wr / CMF =CONCRETE MONUMENT FOUND County Tax Map D-u!r�a 1000 se=!lor� 102 f31xk 04 Lot 8.1 DATE:02/W/2024 y5f CMS =CONCRETE MONUMENT SET EL-34-2 o.o• 4J `�` °e , / FIELD SURVEY COMPLETED APR 05,2024 q DARK BROWN y�� DRF =DEER FENCE MAP PREPARED APR.15,2024 C LOAM ( !y\ EOP =EDGE OF PAVEMENT (Old ! ,' GMF =GRANITE MONUMENT FOUND Record of Revisions os � IPF =IRON PIPE FOUND I •3,,\ / REVISION DATE BROWN CLAYEY ND OL =ON PROPERTY LINE SA _FR (Sq ``\ , A 05 =OUTDOOR SHOWER AMFhMFrT� Mav 3t 2D24 2a, ! RO =ROOF OVER ^�FQAI AMFNtJNA!FA:S .TlMF 2F 2(124 I SPF =SPIKE FOUND ,89 SPS =SPIKE SET PALEBROWN hij°y, `\ S'T WIF =WIRE FENCE FINE TO I �q/moo^p� • O WDF =WOOD FENCE } COARSE SAND ( S0, y \yl, WSF =WOOD STAKE FOUND WSS =WOOD STAKE SET o I 4�✓ey ♦ sQ ® =WELL e '9y�, 40 0 20 40 Bo 120 m n.o' I cA \ -E =ELECTRIC MARK-OUT -yY =WATER MARK-OUT Scale: 1"= 40' - I \ -s =SANITARY MARK-OUT =END OF DIRECTION/DISTANCE JOB NO.2024-0032 1 OF 1 DWG.2024 0032jp li GENERAL REQUIREMENTS: I/A OATS 6 SEPTIC TANK INSTALLATION STANDARDS: Hr ff ' ','fir < 1, `. - --- - -- 547' 2512011E AGRICULTURAL I. The Installer must hold a current Liquid Wae,te License pursuant to I. Install I/A OATS tanks $ septic tanks according to manufacturer's //- I'\\ �,'' • t p - �J�PTIGi P�-f�N NOTE�J -.-b �'� -6 �„�,_LAND � 100.00, Suffolk County Code Chapter 563, Article VI I (Septic Industry recommendations while conforming with these standard. All ` ._�//"' SUBJECT PROPERTY ',�'• !. > ` :a ,, 4 -b-o-,__ _�,_ Businesses) through the Suffolk County Department of Labor, applicable recommendations provided by the manufacturer shall be \I:% w ^ `< "1A O RESERVE - _- Llcensing and Consumer Affairs, pursuant to Suffolk County Code Implemented. _! , ;� y` .'_ I" NEIGHBORING WELL §563-,q. The Department of Labor, Licensing, and Consumer Affaiirs '`^"'.y.; - , ^, b�, UNDER 5GDH5 REF. NO. II p, maintains a list of licensed I/A OATS Matnteriance Providers. 2. The I/A OATS tank 8 septic tank shall be Installed at level In all1. 4, ,!:' .. P: w •. 2 RESERVE R-20-0006 ¢ "' Q I directions (with a maximum tolerance In any direction of +/ one ,•;, . - 2. All I/A OATS must be registered with the Department in quarter Inch) on a minimum 3-Inch thick bed of properly leveled and , �' t ah. r` �; 7 - accordance with Article Iq of the Suffolk County Sanitary Code compacted sand (free from rocks) or pea gravel. i, , I « ', + ,'"r,_t' ' 3 FUJIGLEAN ALARM/CONTROL PANEL d BURIED I ;X, W 4 '� ' O ELECTRICAL LINE FROM I/A OWTS ¢ d W (D prior to the Department granting certification of completed ^, �. ¢ ,,, �•� -- I/ J construction on "as built" plans. 3. I/A OATS Tanks shall be provided with a single outlet. A x t r,.`;, ?"a; 2 FUJIMAG AIR B OWE}R d "� PVG AIR LINE TO I A 4'-O" HIGH FENCE A5 PER V \ M L L / \ distribution box/manhole or distribution Ieachin structure may be . . y;,., 4 I ^ �� 3. An executed Operation and Maintenance contract between the required for all systems with multiple leaching structures unless an i. • A { r + ^,„_ �.' "`� O OATS (PER MANU. SPEC.'S) �A NY5 POOL CODE ill � //\ Q _ CV Maintenance Provider and Property owner must be submitted to the alternative design is approved by the Department. ,' ,-^ �',,`: ' , 11 e Y .' ¢ ¢Q Department prior to approval of the I/A OATS registration by the; 1. " ' , ; - - 1 I t O RESERVE 1 0 I O O � Department In accordance with Article Iq of the Suffolk County 4. All outlets from the septic tank must be provided with an IS" ,, ' _f 'It ,, '°" " a `'" i., "t ti, pO _ V' Sanitary Code. drop "T" or equivalent approved baffle extending into the I/3 of Y ,>;.> a�` fi a - ° ? 1 m - - • �. O GLEAN-OUT. � P�t (� the septic tank liquid depth. Gas deflection baffles are - L. ,�,' j 6 it4. All installed I/A OATS are required to have on initial 3-year recommended for Installation below each effluent drop "T". i . '' „ . I e� , itis ^`, " , - • � ¢ Z O warrant and o erotion/maintenance service contract. After the ` `�; , `'I I ,�_,� '" ,- , - j I TE A O - N I y P , . , ,. 51 L YOUT NOTES Initial 3-year operation and maintenance service contract has 5. The top of the I/A OATS tank or septic tank shall not be located R;"' _:'< . Yid ,, ;'..t. . -;,� „ ��.: _ '� r,' b I I. TH15 IS AN ARCHITECT'S 51TE PLAN 8 15 •� 'q' expired, property owners are expected to maintain on operation greater than 2.5 feet or less than one foot below final grade. I 1, t`., ' • ,!• ,i "' ��..,,� - °11' �_` EL_=_I?.23' � and maintenance contract In accordance with Article Iq of the . ; " , ' M,. R r __ SUBJECT TO VERIFICATION BY A LICENSED O X (V r r -° ; I / ��� \� �� I SURVEYOR. THE INFORMATION O 4- Suffolk County Sanitary Code. 6. At a minimum, all sampling manholes shall have 20-Inch covered - °;, z�a:,, ,' � O Q ' •_•, I ���ti 1 REPRESENTED ON TH15 SITE PLAN 15 TO THE -C O m +� T- access openings to grade located over the inlet and outlet. 2,.` a'",•," ,,w I , ".r , O fi T i 4-r 5. When on I/A OATS requires a vent, the unit shall be vented to the Covers shall be either 20-Inch diameter watertight and �•.I ^.'i >' , ::^ ,,,-••" �"_ 0 ,�,,_ '/�1j 0/ ARCHITECTS BEST OF KNOWLEDGE. (\J O co roof of the residence being served. Vent pipes shall extend a Insect-proof locking cast Iron covers or thermoplastic covers at �,' , '' t . ._ . .r - �...� : �.,- ( 'L� v Q minimum of 6 Inches above the roof line and the top of the vent final grade. All covers shall be designed In accordance with section if, .'.", .•a ,.' - �11 , VM !7' R �I d/ �U$O, / 2, SURVEY INFORMATION WAS OBTAINED Q a shall have a minimum horizontal separation of 12 inches to the 5-III of this standard. { h �. N " o`` `��' ti� S 1 FROM A SURVEY DATED APRIL 05, 20'24, ' e �:.e , 1*�, °,_-I , .y , . ' C ._s . -,.� 6 ! '4,�, o fi EL.=17.02 sloped portion of the roof. In cases where lit Is not practical to t .. w . , - •- I c Nj � ll� / MOST RECENTLY REVISED JUNE 26, 20,24, vent the system to the residence roof, a vent pipe may be piped to ,. When sampling manholes are approved to be Installed in a fi ti parking g LOCATION MAC' I� oG �c AND PREPARED BY: the exterior of the residence and terminate a minimum of 18 inche:s drivewayor arkin area, the manhole shall be designed to be above rode and at least I foot from property lines. These vent traffic bearing to meet the requirements of AA5HTO H-20 or < ¢I i n 1 s all be, located a minimum of 3 feet from an window or HS-20 loading. ll� A � YOUNG ASSOCIATES V/ Pipes y g' SCALE: NTS doorway and must mnimumeiameter ofh a bon 2 incilter hes•devlce. All vent 8 The outlet Invert elevation shall be a minimum of 0.I foot below --._____________-_____" _____-_. _-___-_-___-- ___ ____.._. _._____ .__.._-__-- ___._______-_ . -_ _ ___________. _ , J< ¢I / 400 OSTRANDER AVENUE pipes must have a minimum d - -_ ________-__-._`_� Ir ¢ / RIVERHEAD, NY IIgOI 6. Installation and use of the I/A OATS must conform to the the Inlet Invert elevation. I - ---`�- - - -- -- -^- I! TELEPHONE: (631) -12-I-2505 PROJECT / ZONING DATA 1 I I Department's approved I/A OATS guidance document prepared irn q. Sampling manholes shall have on inside diameter of 2 feet or an ------ - -------_---- ---- I I i / EMAIL: ADMIN®YOUNGENGINEERING.GOM accordance with the standards for "Approval and Management off Inside area of 2 foot by 2 foot. TAX MAP # 1000-102-04-8.1 �i 11, 1 ¢ 1 Innovative and Alternative Onsite Wastewater Treatment Systems.. / 10. There shall be a maximum retention depth below the outlet invert r , MINIMUM DESIGN REQUIREMENTS; elevation of six Inches. C. ZCNING DISTRICT -- - _ AG NON-CONFORMING Ii � v • - ,�--_ - _ �--- __-s,-_ -=- - s 1. I/A OATS 8 septic tanks shall be constructed of precast 11. All sewer pipe penetrations In the sampling manhole shall be Iy (D ,I D concrete, fiberglass, of eth lene, of ro ene, thermoplastics, or watertight. I � L07 GOVERAOF-�� -- -� - s - -- -- - l= � 3 ? � g p y y P yP Py P 9 other materials In accordance with Department standards and , I Q 1kr p IONYCRR, Appendix ,5-A. The use of steel tanks Is prohibited. ELECTRICAL REQUIREMENTS: SOUTHOLD TOWN GODS (SECTION 280- 24) r ? W 0 'I b ' CONTROL PANELS: !![-------- --------_--- - -- - -- A---- --- ----- Uhl w ¢1 AUGUST 21 2024 2. When on I/A OATS requires a septic tank for pretreatment the ONT L L / � AGRICULTURAL = + \\\ septic tank shall be designed In accordance with sections 5-101 I. The control panel box must be placed outside on a suitable i 1 DESCRIPTION (FOOTPRINT) � j ?`RE°` COVERAGE ;II . PPP LAND and 5-IOq of this standard. pedestal near the structure that it serves. Alternatively, the panel ` !_ --_ _ -- - -- �, - __ - -_ - 1d IL Q� Q EXTERIOR HOSE BIB w/ 11 TEST HOLE #2 DATA C , box may be mounted on an outside wall of the structure (preferable - - -- _ -- - ___ ° i ' O WATER SUPPLY LINE / I ! MGDONALD GEOSERVIGES v 3. Unless otherwise specified, the Ieachin structure/system that a utilityroom, and not a livin space). Other locations for mounting TOTAL LOT AREA 42,cl76 S.F. i - - j g Z m I follows on I/A OATS shall be designed in leaching sections g p g _ __ _ ________________________-_-_i -____ - _ _ __ __-__ _ - , S O CONNECTED TO THIS � FOB 1258 g the panel box well be considered by the Department on a 0) 5-10, and 5-I10 of this standard. case-b -case basis and with I/A OATS manufacturer a roval. ! i fI' �� FIXTURE ONLY I SOUTHOLD, NY IIg71 - ---- - --__- -- 1,113 S.F. - -- --2.by= - / I Q1 \ _ - _ - - - - - - - - - - _ I (631) 765-3677 • - y pp DWELLING 1� 4. At a minimum, all I/A OATS treatment tanks septic tanks shall) 2. The name of the I/A OATS 03M Provider must be clearly N th - - - _ I MGDGEO®GMAIL.GOM have 20-Inch covered access openings to grade located over the identified on the outside of the panel and Include a phone number ( i� COVERED PORCH---- -- - ---J / 181 S.F. - \ s -0.4% --1 ] - � - - - " ' inlet and outlet. Covers shall be either 20-Inch diameter watertigiht to contact in case of alarm. STEPS FROM DWELLING I d ; - / �� =/g, and Insect-proof locking cast Iron covers or thermoplastic covers / 1 d EL.=18.8' P g p 34 S.F. 0.I1% I �I I-STRY ND. FR. at final grade. All covers and chimneys/risers shall be designed fin 3. Exterior panel placement enables the system to be serviced at ( ' (TOWARDS DRIVEWAY)- - - = / ____ _!__-- -_ �� \ / dd BUILDING w/ DECKS OL DARK BROWIN LOAM accordance with section 5-III of this standard. any time, eliminating the need to access the inside of the building. _- _- _-- -`-- --- --- --j, II -� _ _ PI! �i�� j (DRY BLDG� 1.0' - r 5. When a I/A OATS or se tic tank is a roved to be Installed in a fa ilita4. The te operation n box u and maintenast be within nnce ew of the system location to help ACCESSORY GARAGE - - -- - --'I ---�352 S.F. -- -- T --0.8� - / - - i 11' - P BROWN SILTY SAND driveway or parking area, he unit shall approved designed and/or p t ¢ ! \ 1-- �1 SM WITH GRAVEL installed to withstand HS-20 or H-20 loading as designated by 5. The control panel shall be placed at a comfortable height for TRELLIS- - - - - - -- ---� - ,� I56 S.F. -f� -- 0.4% - ii I� i I i 5.0' AASHTO. access in accordance with Federal Emergency Management Agency --- ---- ---- ----- ------_-- -- --- - / IRIGATION WELL AS id SLATE I �I (FEMA) flood zone requirements. SHED J � 101 S.F. 0.2% / PER 5GDH5 REF. NO. ? I PATIO I \ --J �I 6. Garbage grinders shall not be permitted when an I/A OATS is _ - _- R-20-0006 I utilized as means of sewage disposal. 6. The panel shall meet National Electrical Manufacturers - �- ____ _ _ -, - - _ -- -..- ---- --- Association (NEMA) 4X specifications. f \, I II, II I J � ,. Water softeners shall not discharge Into on I/A OATS and the p ADDITIONAL SHED 702 S.F. 1.6Jb -' dl i SFACE/ I I Department recommends water softener backwash be connected to L T - - - -- �0 )/1 1 I FOR 1 1,. All below grade wiring must be run in electrical conduit. The p E�, `an onstte drywell acceptable to Town or Village building conduit must have appropriate seals to prevent gases and moisture WD. FR. BLDG. w/ DECKS 1ii ' Iq5 S.F. 0.590 \ ¢ i _� IDepartments. from reaching the control panel or�unctlon boxes. ___-___--s-=___--- '\ _ �' I ,fib/iV i I d TEST I PALE BROWN RAISED DECK w/ HOT TUB 4 I I '�'o 0 1 SP 5. I/A OATS tanks d septic tanks shall be watertight and 8. Each system shall beequipped with a functioning warning system 283 S.F. 0.7�0-- �/ �` HOLE #2 FINE SAND constructed of sound and durable materials that are not subject Ito yg g y OUTDOOR SHOWER �� / _ /�, s`. F - which will activate audible and visual alarms that can be readily i excessive corrosion or decoy, i 1 �II RAG S - EX. EL.-Iq_32' I e ', r he occupants of the building served. The , y seen and heard by t OGG p g INGROUND POOL !648 S.F. _ 1.5� ti11� '4T/�T� _ i _ _ _ _ PROP. EL.-23.0 I Department recommends a telemetry device be Installed to _ __ b'-O" HIGH STOCKADE '4 / - - -- G YI g g provide Immediate remote alarm notification to the 08M provider --- -- `- - --- -----_ - O q. All tanks must be watertight. Two methods of ensuring tanks aree - - ---- -- - - - --_----` - - - - ti C _ _ watertight shall be either vacuum testing or water pressure testing covered by the OBM agreement. ; ; TOTAL AREA OF ALL STRUCTURES 3,765 S.F. - 15.83b---- \ FENCE W/WIRE MESH;_ � 4 l - - - ¢ i methods as follows: ( - -_- - - __- --__- . _I--= -_-- FENCE COMPLIES AS PER q. Systems which are not designed to flow b gravity are11 NYE, POOL GODS ll ` /- E - ' - I 10. Vacuum testing: Seal the empty tank and apply a vacuum to focur y q pp g l p y MAXIMUM LOT COVERAGE ALLOWED: 20`Yo } I _ _ -_i_ - _ _ _ _ _ __ - � `�L1 (4) Inches(IOOmm) of mercury. The tank Is approved If qOG of - - ----- --- _-- - ) -__-_ ----- -- --- -_-- -' 6 4 g' P y PP y recommended to bee equipped with a control anel with means of i - - _ _ _ / y• p1 connecting a portable generator to operate the system during a ---- -- I - - - I vacuum is held for two minutes. ower outs e. - DWELLING w/ I; - _ _ _ - - _- - _ _ - ¢ L 13.5 ��P g NOTE: -" _.i �.__;. = PRIVATE WELL � 5 - - - - - - _ _ �1 c - %/ 11. Water testing: Seal tank;fill tank with water to outlet Invert 9 pump / £' -\ -- afters tihe 24 houard eoriod shcom lete.ILet thent tank stand foran art I. The electrical unction box serving the um motor and floats MAP #: 36I03C0163H �O d - ..____ PUMPS. BLOAERS. LEVEL SENSORS. AND CONTROLS: 1. FLOOD D T : \ J Z - - - - - - - _ �/ RATER IN I 0 p p must be watertight and located outside the I/A OATS tank chamber. MAP DATE: Oq/25/200q I' _ - - - - I - - _ _ _ �I Q 5P PALE SR:OAN additional 10-hour period. The tank Is approved if water level is FLOOD ZONE: X \� 1 i �. - - - _ - eL.cI/,II �i FINE SAND held for the 10-hour period. Water pressure testing is 2. Any blowers located outside of the I/A OATS unit must be placedd - -- _ I I - - I i m recommended to be done onstte after Installation. on a pod (concrete, plastic or fiberglass) and have a soundproof 4 i Q _ _ _ _ _ _ - - 11.O' P p g P 2. SITE PROTECTION/51LT FENCING TO BE _ - - - - - - - D- enclosure cover. WATER SUPPLY LINE � � - - - - -_ - _ ,� 12. Septic tank manufacturers shall provide o label of non-corroslive INSTALLED AS REQUIRED BY THE TOWN OF ( i 0 - - _ <<, ° COMMENTS: GROUNDWATER O t SOUTHOLD. TO REAR YARD HOSE ¢ � - , I I .� material In a prominent location at each access opening to warn 3. All pumps and float trees must be accessible and serviceable BIB � _ _ _ __ _ - _ I f ENCOUNTERED 13.5' BELOW to D that "entrance Into tank may be fatal". from access openings. 3. SURFACE WATERS OR WETLANDS ARE NOT 8'xl2' I-STORY ND. FR. SHED - I � - - _ \� ,`� I GRADE ; 2 m y - E , � I/A OW75 TANK CONSTRUCTION MATERIAL REQUIREMENTS: 4. The floats shall be attached to a Schedule 40 PVC, float tree LOCATED WITHIN 300' OF THE PROPERTY. (<22 HEIGHT) (DRY BLDG.) �1' ) FEBRUARY O,I, 2024 N p that can be Basil removed for service or adjustment. The floats _ -_ __ _ __ - _ ¢ y = 1. Non-concrete prefabricated septic tanks shall conform to the shall not be attached to the force main. J 4. ELEVATIONS REFERENCE NAVD Ig88 -- -- +-____ - �, POOL - - F� ' # Z = o Internatio(IAPMAO)nal Amerloanation of NationaPStanidard�or�P'refabraicatfediSe tic 5. The Deportment shall observe the um system operate through - I -- J ' - TEST HOLE I DATA W < Q9 - �, - ------- - - - - - - _ _ __ PC - - MGDONALD GEOSERVIGES - 4• Tanks" ANSI ZI000-200-1 and an c hr-able revisions/u dates. a normal o operating cycle. pump y p g 5. ANY VISIBLE WELLS, OR FROP05EP WELLS, / I I FOB 1258 Q y PP P P 9 y 1 \- - - - 4C- -- O a LOCATED WITHIN 150 OF SUBJECT ¢ 1 - I SOUTHOLD, NY IIQ71 c� Z 2. Non-concrete tanks shall be factory assembled or assembled Iin b.lnspectlon for leakage of the force main fittings will be made PROPERTY LINES ARE DEPICTED ON 51TE I - - - - % - _ _ I - I (631) 765-3677 - ---- `------ - -- -----r- ----- the field/distribution facilityb a certified representative of the Burin the um test procedure. PLAN. / Il I I i - - _ _ ``� LU - ri tank manufacturer. y p 9 pump p - - - - - _%`a--- - - - - 1 J MGDG305GMAIL.GOM w \ F\ l\ 6. ANY EXISTING SANITARY SYSTEMS / \ ¢ et 3. Each tank shall be identified by the manufacturer with the LOCATED WITHIN 150' OF SUBJECT I - ¢ eV eV manufacturer name or logo, ca acit and number of openings, and) 4'x8' POOL EG2UIP. PLACED MIN. 15' 1 - -----� - - - - - \ - F \ d OL DARK BROWi�I LOAM " g p yPROPERTY LINES ARE DEPICTED ON 51TE j d - i - - 1 - - <.�' -1 0.51 - - ui � o I date manufactured, permanently marked at the Inlet end of the tarok. I FROM SIDE YARD PROPERTY LINE; - , I �� ¢ F- o e-i i BROWN CLAYEY Q FLAN. YJ/ BURIED ELECTRIC WIRES FROM � y � 1 , - - - - - , � � � h __�_�,-_ _ SG p rn N I 4. All walls, floors, roofs, and access covers shall resist an oppllled DWELLING i I 1 EL.=30.46'` \ \ E- - � "--"- "-----� 20 -- - SAND 0 r.1 force of 500 pounds per square foot (psf). 7. PROPOSED SEPTIC SYSTEM DESIGN INTENDS I I I �.� TO AVOID THE REMOVAL OF ANY EXISTING RETAINING WALL AROUND POOL � I 18.0 0i - _„ \ `�'fI , PROJECT: 5. Precast concrete covers and risers are not permitted on TREES. THE PLACEMENT OF SYSTEM I W I RETAINING WALLS EQUIPMENT 4 DUG I' INTO GROUND non-concrete tanks, unless otherwise approved by the manufacturer. COMPONENTS MAY BE ADJUSTED PROVIDED 1 0 -1 F� -- \ 6. Whenever practical, non-concrete I/A OW75 B septic tanks shaall THAT ALL REQUIRED MINIMUM SETBACKS \ not be located within groundwater. For Installations that are placed ARE MAINTAINED. INSTALLER TO CONTACT I - �I l Q ° V I ?' - 6 \ f 4'-O" HIGH FENCE AS PER M 0 LTZ within groundwater, particular care must be taken during installation, ARCHITECT IF RELOCATION OR Ij I O 0 Q,1 - - F TRELLIS II �.,_ f SEPTIC bedding, and backfllling to prevent damage to tank walls, and all REORIENTATION OF COMPONENTS REQUIRED. II I Q� Z m1 ,� NY. POOL '.ODE tanks should be sold by the manufacturer completely assembled. Ilf, I I I A - B II s. All tanks shall be I Z � I -� b because of size, the tank is delivered to the: site In sections, all 8.EXISTING CONTOUR LINES HAVE BEEN � I I I - E� ; ------ joints shall be sealed with watertight gaskets. I 0 I I-STRY. WD. FR ,I \ J 9 g APPROXIMATED BASED ON SURVEYOR 1 N ------------- -- - tested for water tightness after Installation using a method SPOT ELEVATIONS AND SITE 11 I I GARAGE w/ specified by the manufacturer and approved by the Department. I I SLAB I PALE BROWN FINE 1600 ALVAHS LANE OBSERVATIONS. CONTRACTOR TO V.I.F. WOOD DECK ¢ 'j I I �L.o RELATIVE SLOPE OF EXISTING GRADE AND I (DRY BLDG.1 I \ 5Y1 ,. In cases when tanks are Installed In groundwater, the design WELL ABANDONED UNDER � 1 I LAB EL.=34.12 EL.=32.4 TO COARSE SAND professional shall submit buoyancy calculations to prove the weight CONTACT ARCHITECT IF OBSERVED HS REF. NO. R-20-0 O6 - -- - - ---- _ ______J CUTCHOGUE, NY 11935 of the tank (with or without anchoring or the addition of ballast) wvlll SIGNIFICANTLY DIFFERENT THAN SHOWN. 0 I r"- 1 be at least 1.5 times more than the weight of the water displaced. ", •;i 7 x7 HOT TUB WITHIN' ¢ 1 - - _-__ _ i ---- ' _ The buoyancy calculations shall be done using highest - - - J ----- / -- - ---_- - �- - PROF. RAISED-DECK p' IS L I I ASPHALT I \ expected/recorded groundwater elevation with the tank empty. S�oll D15TANGE5 TO 5EP7IG 5Y5TEM GOMPONEN75 � I Ili I DRIVE DRAWING-_TITLE: -------------------- 1 3 mx2 ourpooR cover on top of the tanks) shall not be considered when ( HOUSE DECK DDITION I y - determining the amount of anchoring or ballast weight required. - -T (MEASURED FROM BUILDINCC __-______ __.-=_t-_- r-.-,_�� _____-__._ \I , I I 11 5HOWER DRYWELL - ------ ---- --- ----- - -- CORNERS) /�` I \ NOTES . OUTDOOR SHOWER UPON DECK 1 D i ,, I SITE INFORMATION F SYSTEM COMPONENT 1 CORNER 'A' CORNER-B---I -CORNER-G CORNER 'D' :� DRAINING TO 3'� DRYWELL w/ 1� �- T I I I - \ - -!'' _ _ l ORMATION 1 - - - - ) TRAFFIC-BEARING COVER & TOP - 00 - -- - „E„ - &'(P x 12' LEACHING POOL--- ------- --_---'----- !------ 11 I--- - -- r / - `\ -- VACANT SITE PLAN �__---=-_-- -� - --- --- -- - ----- I6 - - -- --I------- !' 4-HIGH FENCE AS PER �o r� " W \ 6 I LOT SUFFOL�G COUNTY HEALTH D i� i�'TM�NT fi�i�i�O� L ' I _ ] ------ -- 1-- - - \ NY5 POOL CODE / H.S. IREFE ENGE NO. R-24-10P 3 -----„F„ - 8'm X 4' LEACHING Pool --I _ 128' _-----124------ - __ - _�- - J \ I,.o' - - ' <` H \ ------ \ I \ , PAGE. I 2-STRY. WD. FR. \ \ \ \ GK COMMENTS: NO GROUNDWATER r^- c, A �_ �' - "- I L=--_----- _20" DIAM. POLYLOK MIST. BOX ---- I I�l --- -- ---_ ------, l / ( � \ 1 ss.�� ENCOUNTERED. " � r:I I r f /� �- _ [' `i : --- -_ ----- _- --= -=--_-_-__-_-_----_-- I I6' ' t_ -! s ( R � DWELLING w/ \ \\ 15 4 ' - "" " ' '' �' s- I F e ` "H" - FUJIGLEAN GEN 5 I/A OWTS - - � 5ci' 44' \ / / i BASEMENT $ � INS V M V��L1 \-P' _ . I 1. O GE�O I /� R -_--- _ - _----- -_-.__ - - _-------- GRAWLSPAGE �• I N o 5 to 0 40 0 0 I %_2 -:10 1:."" k`` e` - � L �1�') 0 :_5 U .,,►�� `t ,,, � , - _ - - ---=_-- ___-------- i / / BURIED GAS 1 1 (4 BEDROOMS) �i� `�� I M\N G1S�P In ' MEASUREMENTS AS PER SYSTEM INSPECTION CONDUCTED ON OCTOBER 16, 2024 BY ND5 PLUMBING 8 HEATING. I i F.F. EL.=37.25' I�� \ ( I 6RAPHIC SCALE r' r { r'- *-" NOTE: MEASUREMENTS ARE TO THE CENTER OF COVERS. LINE I 1i I Ic 11 \ I \ r, , - n. -, - \ - fir. i"\ ._,_ , \ ,._. %^ ,.-" j 1 N AG ' I I DATE: 09/05/24 1 OF 1 DRAINAGE SYSTEM INSTALLATION NOTES: / K • A MINIMUM 10' SEPARATION IS REQUIRED BETWEEN DRYWELL5 8 i i I �-�- � . COVERED PORCH LIN ROM w 'LL (MIN. I LINE OF 50' I '� 12/16/2024 I._� n' ' ! R-24-1083 WATER SERVICE LINE, UNDERGROUND UTILITY LINES, SEPTIC w i w P O' I SETBACK FROM WELL �' `` - - - .. - - COMPONENTS, LEACHING FIELDS, SEWER COMPONENTS, OTHER I I - ¢ I DIST1 TO (MIN. DISTANCE TO .., ) \' DRYWELL5, AND THE EDGE OF ALL FOUNDATION WALLS tV I SANITARY LINE) r t A MINIMUM 5' SEPARATION 15 REQUIRED BETWEEN DRYWELL5 $ O Qr ( I I I ® 1 Gv , "° t,,,, f'� r,. i ., -" "",1,',� ,��, R -+` �,- PROPERTY LINES i I IU'' \ Q� ip F j@ �+��,t {p/�ARM@ ((, ¢''� •-%`•; 4 r b,. ...., C .,,,. �d e.• ,7,, t`. I"...¥ �,: �.. b �.>�� + � •,,.I I I I b. 4 Ii y.: 1? c,..°'�, \4 1y�y F F• b'rn F::w- ,i ' , j A MINIMUM 20 SEPARATION IS REQUIRED BETWEEN DRYWELL5 AND I ' -t[ �'11 WELL �� TEST 1 r >�. 4m " . o 't ► a f I .n ,, e n ^er r^, :r-, ,�, a, ,r 4 BURIED PROPANE FUEL TANKS. I � Z I SLATE HOLE #I 3 1 :- , '' (;tED�Q iI i, 7._.r. Cc: F, = I( ( E .. �I ) fnt� .> E �C l t;�-I�t C�� Ci f . • . c,r , • ;. c- i a <. . A MINIMUM 2' VERTICAL SEPARATION IS REQUIRED BETWEEN THE 1 I WALK IO I 5 s , � � O i l / I I� � I C�� M. O p`�I �^ BOTTOM OF DRYWELL5 4 THE HIGHEST EXPECTED GROUNDWATER \ Ii r, S a f`-f1 .�^ r y F t.../i �'�. ,r { I`.r' 10I J� r 4 r3 E�p-�,'t,..f R ",� - - --- I g I Z I�,� .. ..3 e:,i lo..�c.'..�>t`�4t f � I : �. �„�� . . � � t...>I�- t..�;�'�..)i � a Ja. ELEVATION. � i i �• CONNE07 ALL GUTTER LEADERS TO NEAREST DRYWELL - -- - --- - ______ __ I i / '• O � ,s • SEE ALSO DETAIL ON CONSTRUCTION DOCUMENTS \ \ UTILITY POLE i N47 O8 4�„W -- / ___ / 1 N t2,002 I ' * - �� �`' '' '� DRAINAGE SYSTEM CALCULATIONS:- \ \ _-_ ,-�� ----�r�__ �_I W� EL.=35.6q i - - - - - - - - - - - - J 100.00 � X POOL VOLUME = 173.8 S.F. (GROSS-SECTIONAL AREA) x IS FT = 13g0.4 G.F. \ ---__- -- 7 - /- - - --- - __ _ _ _ _ IX, 037405 O� �'+,f�^" .!°' 1 7 I POOL DRAINAGE REO.'D = 5Y x VOLUME = 53b x 15,10.4 G.F. = 6q.52 G.F. _ _ ��/� EL.=337q- - - �F NE� TOTAL STORAGE VOLUME REG.D = 6gS2 G.F. \ - \ /A} I�\/ /-� - -- / -- ----------)�----- _ �� '-' �,,;,r-e. ^.f.l ',f.•' p,m't, '.,, I r ,e^f,„, f��`7 v'^'t,-, , ` !. N 1"'� I ----- ---- Ji«-f C^i . ,:., ..-.,..�:: ti- . r r, ' .�-g,,.,M,,,rt SITS �L�N \ / t S L A N � UTILITY POLE (1) 8'0 DRYWELL PROVIDES 42.22 G.F. PER FT. OF DEPTH / (I) 8'0 x 2' DEEP D.W. PROPOSED = 84.44 G.F. STORAGE FROVIDED . \ SCALE: I" = 210'-O" III 547' 25'2011E AGRICULTURAL LAND 100.00' 51TE PLAN HATCH KEY: PROP. NEIGHBORING ® PROPOSED BUILDING ADDITION WELL UNDER SGDHS PROPOSED ACCESSORY STRUCTURE r ` d REF. NO. R 20 0006 Q 1 PROPOSED 2ND STORY O ` L 1 (B PROPHIGH FENOGE AS PSED IER NY5 I J POOL CODE C7 I 1 0 SITE LAYOUT NOTES: . .•,._,,.. ...,`F ���.»,. ,.,,.fir .-...�.•�.�•..,�,..�,..�.,,,..•..,�^^,�-° ;�; •��•-�,r^*. --�..,.•.,.•..,,...I.,. ..,.,, .�.,�.-.-..,.,,�u,,.•�,- � C � ,� .,, I. THIS 15 AN ARCHITECT'S SITE PLAN 8 IS ^�. ,� t ,4 ` „ '� h O • 0 SUBJECT TO VERIFICATION BY A LICENSED APPROVED AS fOTEo Q `��` I SURVEYOR. THE INFORMATION .' OCCUPANCY it = } O REPRESENTED ON THIS SITE PLAN IS TO THE „� °'; „ '� "`h ; �'' '` ' ';=`r `' DATE: • v� o? B.P. USE IS USllt !l fCt 1� Z O ` I ARCHITECT'S BEST OF KNOWLEDGE. i t R�.. „ f i I11 L11 1 lJ Q N O Lo EL.=17.23' 2. SURVEY INFORMATION WA5 OBTAINED Y" ` FEE 3 BE: V��ITOUT CE TIFICATE a � e ,r�': va; '_. ,.- °�_, ,'••,.:. NOTIFY BUILDING DEPARTMENTAT X U CV 1 ` I FROM A SURVEY DATED MARCH 25, I qa6 ; ;�".; r 631-765-1802 SAM TO 4PM FOR THE c i ♦ AND PREPARED BY: R' : .° a..� '' :a ♦` I E i R r FOLLOWING INSPECTIONS: OFOOC .'Y o m I ♦ I PEGONIG SURVEYORS, P.G. ^t'' �.rt �; ,�. ,,:.� CV O Q Ln ` ♦ N.Y. STATE LAND SURVEYOR #<, I FOUNDATION-TWO RE©UiRED �-' FOR POURED CONCRETEo. Q O EL.=17.02 1 "� :"" "E a �^ 2. ROUGH-FRAMING&PLUMBING a- O `♦ P.O. Box aoa I F �. '" `�; RETAIN STORM WATE RUNOFF I 1250 TRAVELER STREET "r'' F :Via. INSULATION PURSUANT TO CHAPTER 236 ♦ SOUTHOLD, NY lla7l �" f ',' .� 4. FINAL-CONSTRUCTION MUST % 1 " ' r �' ` BE COMPLETE FOR C.O. OF THE TOWN CODE. (631) '765-5020 d' ^^ 11 ♦ �r ` ALL CONSTRUCTION SHALL MEET THE W I I � h 'wi r ag REQUIREMENTS OFTHE CODES OFNEIN � YORK STATE. NOT RESPONSIBLE FOR I N G n PLUM DESIGN OR CONSTRUCTON ERRORS WASTE '+ I ALWATER LINBIN S NEED AST TESTING BEFOR COVERING ,4, .a'•FM #° "Ytj; {, ~`i,s `r-' .l:, _ .:a iw ;p �1...7-- I _.._.._ ... .. • _ y M �' !y • '.M^ F I. J COom� r 'r f iYOR: STATE&TO' COO"SLu 1 �" �.3's^`s'�'� '� .8� �- �� ��W`y~ •{•�E.�,i T .�' Y� � RW ?`4 i Y 1 Y AS REQUIRED ND ,.,.M z lU AGRICULTURAL LAND [A m EXIST. EXTERIOR HOSE Q •ter * JiCrtF�►iiJ..•. ..3: BIB w/ WATER SUPPLY � - , •� - -• - - �^ N 4 I LINE CONNECTED TO I LOCATION MAC' It or, I.'� F- 3.. � THI5 FIXTURE ONLY 1 - - - - - - - - - - - - - - - "`'� w - - - SCALE: NT5 """ U) 1 EXIST. I-5TRY WD. CL W FR-DE BUILDING w/ �� �� ��� Q \\ DECKS (DRY BLDG.) I 1 - EXIST. WELL AS I PROP. SEPTIC EXIST. LEACHING POOLS; - PROFOSEC) INTERIOR <ITGHEN REND\VATION PROPOSED N ER SLATE I SEE SGHD PLANS �ROi=. 1�1D. REAR D�GK l�l/ HOT TUB - I •OD PROJECT LOCATION &SCOPE ABANDONED UNDER PATIO ; I SITE PLAN & ZONING DATA SGDHS REF. NO. I R-20-o006 I RO�I ` T DATA -OO2 QQ GENERAL NOTES I � 1 TEST ` 1 HOLE #2 ♦ EL.=la.32' ENERGY TABLE EXIST. 6'-0" HItSH I _ _ _ �� - - - - - - - - - - - - - - - PROJECT / ZONING DATA STRUCTURAL DESIGN CHARTS STOCKADE FENIGE - k to - - - - _ TAX MAP # 1000-102-04-8.1 W/WIRE MESH; FENfCE � I - - I //�� PROPOSED DEMOLITION PLANS COMPLIES AS PER NlYS ZONING DISTRICT AG NON-CONFORMING - ( O I .O�- __- PROPOSED POOL COPDE 1 _ _ _ _ � '- - - -;per- - - - - - - - - - - - - F�.,� 1 PROPOSED FOUNDATION PLAN DWELLING w/ I I i IL - ' - - I LOT AREA 1.0 ACRES PROPOSED w _ _ - j _ _ PRIVATE WELL 1 - - - - r i p� - - - - - - _ _ _ F�'\_ _ I GofO - MAIN DWELLING 8 05/O6/ab; #Z24332 DETACHED GARAGE � �o GofO -COVERED PORCH I2/3o/I5; #38008 - 02 .0� PROPOSED FLOOR PLANS 1 134- - - - - - - - - - - - - - - - - F� '� PROP. RELOCATION OF WATER SUPPLY LIINE TO I _ _ _ - X - - - - - - - - - - - - - GofO - SHED 02/OI/05; #Z30736 REAR YARD HOSiE BIB - � I w - - _ _ F�.c��, I PRIOR VARIANCE APPROVAL 02/07/oa; #6120 -�O I.•�jv PROPOSED EXTERIOR ELEVATIONS PROP. RELOCATION OF EXIST. 8'xlZ 1-5TORY WD. FR. SHED - _ �s SUFFOLK COUNTY HD APPROVAL R-24-1055; 4 BEDROOM (<22' HEIGHT) (DRY BLDG.) I _ _ _ _ _ I - - - -i- - - - - - - - _PROP _ I FLOOR AREAS PER SOUTHOLD TOWN CODE, SECTION 250-20-7 (A)(1)(b) Z 1 -- -+--- _ - - POOL _ , \ �4. EXISTING EXISTING HABITABLE GROSS -�-0 � .OD DESIGN DETAILS SPACE AREA PROPOSED STRUCTURAL PLANS 0 I . . - - - � _ _ _ 1 FIRST FLOOR AREA 1,203 S.F. 1,203 S.F. � PROVIDE STAIRS TO ACCE55 REAR - - ' EXIST. DR�V WAY SECOND FLOOR AREA 1,05�i S.F. 1,05Q S.F. j=- I Q I •QQ PLUMBING RISER DIAGRAMS YARD; TBD 51ZE/COUNT IN FIELD I , - ' _ _ _ _ _ PATIO TO BE F�\; w 1 AREA TOTALS 2,262 s.F. 2,262 S.F. GAS RISER DIAGRAM � PROP. 4'xe)' POOL EQUIP. PLACED I _ MIN. 15' FROM SIDE YARD I � � wI , ' EL.=30.46'- , � a F � _ PROPERTY LINE; PROVIDE BU)RIED I I /18.0 / wl �• 8 LIOT COVERAGE _ ELECTRIC WIRES FROM EXISTING j /p pj EXIST. RETAINING WALLS PROJECT: DWELLING (UN:OER SEPARATE FILLING) i I i�p 5>OUTHOLD TOWN CODE (5EGTION 280-124) PROP. RETAINING WWALL I I /� 11- N m� - - - ' - % LOT M 0 LTZ (UNDER SEP. FILLING) � O _ _ \ � PROPOSED MIN. 4-O 'DESCRIPTION (FOOTPRINT) ?`RE?` COVERAGE jz tu ��O p j EXIST. _ , F� .`3, HIGH FENCE AS PER NYS, /7 7- g FL to i� TRELLIS _ 1 POOL CODE 'TOTAL LOT AREA 42,cl76 S.F. RESIDENCE EXIST. SHE'D TO �r I ST. 1-5TRY. EL•=32?5' F� ; BE RELOGAATED I /� - WD. FR. EXISTING DWELLING 1,115 S.F. 2.690 GARAGE w/ SLAB �•;3 r ;EXISTING COVERED PORCH 181 S.F. 0.4% 1600 ALVAHS LANE EXIST. WELL AS PROPOSED PROP. 7'x-l' HOT =a�J N (DRY BLDGJ EL.=32.44' !EXISTING STEPS FROM DWELLING TO BE ABANDONED UNDEiR��TUB WITHIN PROP. - - BLAB E .=3 _ _ 3LG' (TOWARDS DRIVEWAY) SGDHS REF. NO. R-20-o006 RAISED DECK � � -------- EXIST. 34 S.F. 0.190 C TCHOGUE, NY 11935 I ASPHALT LINE D, EXIST. ] !EXISTING ACGE55ORY GARAGE 552 S.F. ob% PROF'. HOUSE DECK / `� I DRIVE TO GARAGE OGATION ADDITION , BE MODIFIED I DRAWING TITLE: �. AS SHOWN 'EXISTING TRELLIS 156 S.F. 0.49b PROJECT LOCATION &SCOPE RELOCATED OUTDOOR SHOWER UPON I � � I EXISTING SHED DECK DRAINING TO 3') DRYWELL w/ I `" 15.7' 1 V L TNT i(TO BE RELOCATED) 101 S.F. 0.290 SITE PLAN &ZONING DATA TRAFFIC-BEARING COVER 4 TOP - - ------ -------i EXI5TIN5 SHED EXIST. 4'-tJIIGH FENCE AS C)C) i(TO REMAIN) 702 S.F. 1.6% PER NY'S POOL CODE \ k ,� � `� !EXISTING WD. FR. BLDG. w/ DECKS lay S.F. 0.590 .0' I EXIST. 2-5TRY. I PROPOSED RAISED DECK W/ HOT 5 PAGE: I ( i ND. FR. � � ` 1 'TUB 2 3 S.F. 0.730 DWELLING w/ \ I PROPOSED INGROUND POOL 612 S.F. 1.4% G-00J. 00BASEMENT S 1 � I GRAWLSPAGE � `� EXIST. BURNED I I (4 BEDROOMS) 1 'TOTAL AREA OF ALL STRUCTURES 3,72ci S.F. 8.79b GAS LINE i w I F.F. EL.=37.25' r� 58cl I MAXIMUM LOT COVERAGE ALLOWED: 20% DATE: 09/25/24 1 OF 7 EXIST. COVERED Q ZONING REGULATIONS MAIN BUILDING 1 WI PORCH to ! i 1 5OUTHOLD TOWN CODE ( 280 - 124 ) ° I � I o Xj 1 lyn 0 1 EXIST. PROPOSED COMPLIES SOUTHOLD TOWN CODE 280-247 (A)(1) (V I I EXIST. TEST z Oj ° WELL SLATE HOLE #I I +� LOT SIZE / AREA IN �1,s O MIN. FRONT YARD 50.0 2a.7 2a.7 NO ALLOWABLE TOTAL 1 EXCESS OF 40,000 42,1I'16.0 S.F. 2116.0 S.F. '�• `,�`°-' f ° ' N I i WALK 1 ty Z (EXIST.) GFA GFA W _ *NO (e) LOTS CONTAINING 7100 S.F. r c - _ I MIN. 51ME YARD 20.0' 11.0' 11.0' (EXIST.) UP TO 80,000 S.F. MAX. ? f < MIN. COMBINED ALLOWABLE S.F. / -+-- - I 40.0' ba.Q' ba.a YES PLUS 5% OF EXGE55 EXIST. UTILITY POLE I i N4'1' 08'40"W �'- - ... _ __ _� t2,002' SIDE YARDS 5,100.0 S.F. 149 .b S.F. 5,248.5 S.F. 2,341 5.F. �i - - - - - - - - - - - - - - 100.00' � G G I LOT AREA OVER .•. ,.G• ' �RO�OSE� S I TE PLAN MIN. REAR YARD 60.0' 346.2' 331.a' YES 40,000 EL.=3 - - - - C- EXIST. UTILITY POLE - MAXIMUM HEIGHT 55.0' 22.v 22.8' YES I A L I/ A H ' S L A N � 50ALE: 1 - 15'-011 PROPOSED WORK DOES NOT INCREASE EXISTING NON-CONFORMING SETBACK PLUMBING //�� I G G ¢ G }�I CARPENTRY WOOD FRAMING MATERIAL STANDARDS I. CONTRACTOR SHALL INSTAL.L WATER SUPPLY, DRAIN, WASTE, AND VENT (DWV) �� �I r 'tT I O I�LJ NOTES $ SPEC,I F I CHAT I O I VIS I. ALL LUMBER SHALL BE DOU6LAS FIR LARCH #2 4 BETTER (Fb = 6*75) UNLESS THE PROVISIONS OF THIS STANDARD ARE NOT INTENDED TO PREVENT THE USE SYSTEMS TO NYS PLUMBING GcODE AND NYS DEC, REGULATIONS. IT 15 THE CONTRACTOR'S RESPONSIBILITY TO KELP THIS CONSTRUCTION DOCUMENT BINDED OTHERWISE NOTED. OF ANY MATERIAL OR METHOD OF CONSTRUCTION NOT SPECIFICALLY TOGETHER AT ALL TIMES. IT 15 ALSO THE CONTRACTORS RESPONSIBILITf IrO READ ALL NOTES, PRESCRIBED HEREIN. WHEN IT CAN BE SHOWN, AND THE AUTHORITY HAVING 2• PROVIDE HOT AND GOLD SHUT OFF VALVES AT ALL FIXTURES. BD. BOARD 11 IN5UL. INSULATION 2. ALL LUMBER IN CRAWL SPACES TO BE 18 ABOVE SCRATCH GOAT. MAINTAIN JURISDICTION FINDS BY EXPERIENCE,MODELING, OR TESTING BY AN APPROVED SPECIFICATIONS,AND BE FAMILIARIZED WITH THE PLANS PRIOR TO WORK 2. MIN. FOUNDATION EXPOSURE. AGENCY, THAT A PRODUCT OR PROCEDURE PROVIDES EQUIVALENT OR 3. ALL WATER PIPING TO HAVE GLEAN OUTS AT ALL CHAN&E5 IN DIRECTION BFE BASE FLOOD ELEVATION INT. INTERIOR a GREATER STRUCTURAL SAFETY OR DURABILITY, SUCH PRODUCT OR PROCEDURE Q SHALL BE DEEMED TO CONFORM TO THE REQUIREMENTS OF THIS DOCUMENT AND AT BASE OF VERTICAL 1^VASTE PIPES. GENERAL 3. SILLS TO BE P.T. AND SECURELY FLASHED WITH A TERMITE SHIELD, ALSO BLD6. -� BUILDING K KIPS (1000 LBS) 0 PROVIDE SILL SEAL/INSULATION. SIZE OF SILL TO BE (2) 2"xb",UNLESS (I) 2"x6" (THIS DOCUMENT IS TO MEAN A REFERENCE TO THE CURRENT AMERIGAN WOOD 4. USE 4" CAST IRON THROU6Hi FOUNDATION WALL AND PITCHED AT I/8" PER W I. NO WORK TO START UNTIL APPROVED PLANS ARE OBTAINED FROM THE IS NECESSARY TO MATCH FLOOR HE16HT5 WITH THE EXISTING STRUCTURE. COUNCILS WOOD FRAME CONSTRUCTION MANUAL AND THIS PS FORMAT,AS FOOT. BM BEAM MANU. SPEG.'s MANUFACTURER'S SPEGIFIGATIONS W APPLICABLE BUILDING DEPARTMENT. APPLICABLE AS A DERIVED WORK). J CD 2. ALL CONSTRUCTION SHALL BE PERFORMED IN A WORKMAIN LIKE MANNER. 4. AT FLUSH FRAMING USE 16 OA&E METAL JOISTS HANGERS BY "TECO" OR 5. GENERAL TRAP AND WASTE SIZES AS FOLLOWS, UNLESS OTHERWISE NOTED: B.O. BOTTOM OF MAX. MAXIMUM1. EQUAL. I. IDENTIFICATION: ALL SOLID-SAWN LUMBER, GLUED LAMINATED TIMBER, - M15H WASHER..........................................2" Q a-' fV ALL DIMENSIONS,CONDITIONS,AND APPLICABLE INFORMATION OF EXISTING BOT. BOTTOM MECH. MECHANICAL a C STRUCTURE/SITE SHALL BE FIELD VERIFIED BY GENERAL CONTRACTOR. PREFABRICATED WOOD I-JOISTS, STRUCTURAL COMPOSITE LUMBER, - KITCHEN SINK.........................................2 Ln 5. MINIMUM, DOUBLE HEADERS AND TRIMMERS AROUND ALL OPENINGS IN PREFABRICATED WOOD TRU55E5, GYPSUM, HARDBOARD, AND STRUCTURAL - LAVATORY................................................2 b7 3. ALL WORK SHALL CONFORM TO NATIONAL, STATE, AND LOCAL CODES FLOORS, ROOFS,AND WALLS. PANELS,SHALL CONFORM TO THE APPLICABLE STANDARDS OR GRADING - SHOWER/TUB,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,•2" B.O.W. BOTTOM O WALL MIN. MINIMUM RULES SPECIFIED IN 1.1 THROUGH I.b. - TOILET.........................................................5" _ -� � O AND AUTHORITIES HAVING JURISDICTION. 6. DOUBLE ALL JOISTS UNDER PARALLEL PARTITIONS, POSTS, AND BATH TUBS, - LAUNDRY ..................................................2" G.J. CEILING JOIST NAVD55 NORTH AMERIGAN VERTICAL DATUM OF Ia88 +-; a � (D 4. ALL UNNOTED OR NON-VISIBLE EASEMENTS ARE THE RESPONSIBILITY U.O.N. I.I. LUMBER: ALL WOOD MEMBERS USED FOR LOAD-BEARING PURPOSES, - FLOOR DRAIN...........................................5" i V_ 4. THE NNOTEI/BUILDER INGLUDIN6 END-JOINTED AND EDGE-GLUED LUMBER, SHALL BE IDENTIFIED 0 C (�J Z O 1. ALL BEAMS, GIRDERS, ETC. TO HAVE MIN. OF 3-1/2" BEARING BY THE ORADEMARK OF A LUMBER GRADING OR INSPECTION AGENCY 6. ALL SYSTEMS TO HAVE ONE 5" MAIN VENT STACK AND INCREASED TO 4" COL. COLUMN NYC, BG NEW PORK CITY BUILDING CODE a •� Ln � � 5. ANY OMISSIONS OR DISCREPANCIES OF PLANS AND/OR JOB CONDITIONS WHICH PARTICIPATES IN AN ACCREDITATION PROGRAM, SUCH AS THE THROUGH ROOF. ^ U •- 8. MIN. HEADER TO BE (2) 2"AO" UNLESS OTHERWISE NOTED. AMERIGAN LUMBER STANDARDS COMMITTEE OR EQUIVALENT. THE CONT. CONTINUOUS � O.G. ON CENTER )( CV SHALL BE CLARIFIED WITH THE ARCHITECT/ENOINEER BEFORE PROCEEDING 6RADEMARK SHALL INCLUDE AN EASILY D15TINOUSHABLE MARK OR 0 0 .- 1 WITH THE WORK. INSIGNIA OF THE GRADING AGENCY WHICH COMPLIES WITH THE D PROVIDE FROST-PROOF SIE BIBS WITH EASILY ACCESSIBLE DRAIN DBL. DOUBLE I OGG. OCCUPANCY 0 O (D q. ALL WOOD SILLS AND WOOD IN CONTACT WITH MASONRY/CONCRETE TO BE DRAIN GOOKS AS REQ'D. HOUSE BIBS SHALL BE PROVIDED WITH BAGKFLOW _c O m 4-J ,_ P T REQUIREMENTS OF U.S. DEPARTMENT OF COMMERCE P520-9Q. PROTECTION. +J co Ln b. NO DEVIATIONS OR CHANOE5 TO THE STRUCTURAL SYSTEM SHALL BE MADE DFE DESIGN FLOOD ELEVATION O.H. OVERHANG � n1 p UNLESS APPROVED BY THE ARCHITEOVENOINEER. 1.2. 6LUED LAMINATED TIMBERS: GLUED LAMINATED TIMBERS SHALL MEET O 10. ALL EXTERIOR SHEATHING SHALL BE NAILED AS PER FASTENING SCHEDULE 8. WASTE FROM CLOTHES WASHERS AND LAUNDRY TUBS ARE TO BE PROVIDED DIM. DIMENSION PBFE PRELIMINARY BASE FLOOD ELEVATIOI�I Q '- a 2 � 1. CONTRACTOR TO VERIFY DIMENSIONS OF FOUNDATION WITH FLOOR PLANS ON PACE 6-003. GENERALLY, SHEATHING 15 OF 1/2" THIGKNE55 ON WALLS AND THE PROVISIONS OF AN51/ALTO A 10I0.1 STRUCTURAL 6LUED LAMINATED WITH BACK FLOW PROT'ECTIONI. BEFORE THE START OF FRAMING ROOF AND IS OF GDX GRADE, UNLE55 OTHERWISE NOTED. SEE FLOOR PLANS TIMBERS. D.J. DECK JOISTS P. GONG. POURED CONCRETE FOR ADDITIONAL NAILING OR DIFFERENT NAILING REQUIREMENTS WHEN 11. THE WATER SUPPLY AND SANITARY SYSTEM SHALL COMPLY WITH LOCAL 8. DRY WELLS AS REQUIRED BY STATE ,AND LOCAL CODES. APPLICABLE. 1.5. PREFABRICATED WOOD I-JOISTS: A55EMBLIES USING PREFABRICATED HEALTH DEPARTMENT STANDAkRD5 AND REGULATIONS. EA. -� EACH PL. PLATE WOOD I-JOIST5 SHALL MEET THE PROVISIONS OF ASTM P5055 /� 11. SUB FLOORING,GENERALLY, TO BE OF 3/4" THICKNESS AND OF GDX GRADE. STANDARD SPECIFICATION FOR ESTABLISHING AND MONITORING 10. APPROVAL AND INSPECTION 15 REQUIRED BY LOCAL JURISDICTION PRIOR W Q. DO NOT SCALE DRAWINGS, WRITTEN DIMENSIONS TAKE PRECEDENCE STRUCTURAL CAPACITIES OF PREFABRICATED WOOD I-JOISTS, THIS ELEV. ELEVATION PLYWD. PLYWOOD NAILING AS PER FASTENING SCHEDULE ON PAGE 6-003 AND 6LUED,U.O.N. TO CONGEALMENT OF PLUMBINUG. DOCUMENT, THE 60VERNINO BUILDING CODE AND ANY ADDITIONAL L_ 10. OWNER/BUILDER ARE RESPONSIBLE FOR ALL INSPECTION'S, APPROVALS, 12. EXTERIOR SHEATHING TO BE COVERED WITH 'T'YVEK' HOUSE WRAP OR REOUIREMENTS AS SET FORTH IN THE MANUFACTURER'S CODE 11. NOTGHIN6 AND BORING OF :57UDS, JOISTS, RAFTERS A5 PER BUILDING CODE. EQUIP. EQUIPMENT P.T. PRESSURE TREATED CERTIFICATES, CERT. OF OCCUPANCY OR COMPLETION AND IU.L. APPROVAL APPROVED EQUAL. EVALUATION REPORT. NO NOTCHING AND BORING OF STRUCTURAL MEMBERS SHALL BE PERMITTED D 11. THESE SET OF DRAWINGS ARE THE PROPERTY OF ANTHONdY PORTILLO, RA NOR ANY POTENTIAL DAMAOEE THEREOF. EXIST. EXISTING I REQ D -� REQUIRED AND SHALL NOT BE ALTERED OR BE REPRODUCED WITHOUT WRITTEN 13. BLOCK EXTERIOR STUD WALLS AT HALF STORY HEIGHTS AND AT 1.4. STRUCTURAL COMPOSITE LUMBER: SINGLE MEMBERS OR ASSEMBLIES EXT• EXTERIOR Ri RISER 4� UNSUPPORTED EDGE SEAMS OF EXTERIOR SHEATHING. USING STRUCTURAL COMPOSITE LUMBER SHALL MEET THE PROVI5IONS OF 12. PER NY5 PG 425.4, A 4"x3"' CLOSET BEND SHALL BE AN ACCEPTABLE PERM15SION FROM THE ARCHITECT. ASTM M5456 STANDARD SPECIFICATION FOR EVALUATION OF r 1 WATER CLOSET GONNEGTION. INHERE A 3 BEND IS UTILIZED, A 4 x3 FLANGE V 12. THE ARCHITECT IS NOT RETAINED FOR SUPERVISION OF T'HE WORK AND 15 14. PROVIDE 'X' GROSS BRACING AT JOISTS, STUDS,AND RAFTERS WHEN SPANS STRUCTURAL COMPOSITE LUMBER PRODUCTS, THI5 DOCUMEN THE SHALL BE INSTALLED TO RECEIVE THE FIXTURE HORN. F.A.I. FRESH AIR INTAKE RM. ROOM EXCEED 8'-O" AND AT EVERY 8'-O". SET FORTH I VERNINO N THE INS CODE, AND ANY MANUFACTURERS CODE EVALUATION AS FAR FLOOR AREA RATIO R.R. ROOF RAFTER RESPONSIBLE FOR DESIGN INTENT ONLY. FOUNDATION. CONCRETE, AND MASONRY 15. TOP PLATES TO BE DOUBLED AND LAPPED AT CORNERS, 5EE ALSO PAGE I. CONTRACTORS TO VERIFY ALL DIMENSIONS OF EXISTING FOUNDATION AS IT (�� 13. THE CONTRACTOR SHALL OBTAIN GEf?TIFIGATE OF OCCUPANCY. 6-004. 1.5. PREFABRICATED WOOD TRUSSES: A55EMBLIE5 USING PREFABRICATED APPLIES TO THE NEW WORK BEING PERFORMED AND SHALL COORDINATE THE P.A.V. FRESH AIR VENT STL. STEEL ""'�� W WOOD TRUSSES SHALL MEET THE PROVISIONS OF THIS DOCUMENT,THE 5UB-CONTRACTORS IN SUCH A MANNER TO A55URE THAT THE CONDITIONS OF 14. THE TIMES. ATTHE CONTRACTOR COMP SHALLETION KEEP PREMISES CONTRACTOR H ALEAN AT ALL ALL 16. APPLY ALL CONDITIONS ADDRESSED IN FASTENING SCHEDULE AS GOVERNING BUILDING CODE, AND ANY ADDITIONAL REQUIREMENTS AS THE FIRST AND SECOND FLOORS ARE TAKEN INTO ACCOUNT. FF FINI5HED FLOOR I S.V. SMART VENT RUBBISH, WASTE MATERIALS, TOOLS, ETC:., GLEAN GLA55 ANID LEAVE WORK NECESSARY. SET FORTH IN AN51/TPI I NATIONAL DESIGN STANDARD FOR METAL PLATE 2 ALL FOOTINGS TO BEAR ON[ FIRM, VIRGIN, UNDISTURBED SOIL CONNECTED WOOD TRU55 CONSTRUCTION, THE TRU55 DESIGN DRAWINGS, FF ELEV. FIRST FLOOR ELEVATION TBD TO BE DETERMINED BROOM GLEAN. 11. PROVIDE ALL NAILING AND STRAPPING ADDRESSED ON PAGE5 6-003. OR THE MANUFACTURER'S CODE EVALUATION REPORT. 0 1 3. 501E TO HAVE MIN. BEARING CAPACITY OF (U TON/SQ. FT., U.O.N. F.J. FLOOR JOISTS �TEMP GL. TEMPERED 6LA55 t,.J 15. THE CONTRACTOR SHALL CARRY WORKMAN'S COMPENSA':TION AND GENERAL 16. AT 1.6. GYPSUM: GYPSUM MATERIAL USED IN A STRUCTURAL APPLICATION SHALL LIABILITY INSURANCE. ALL SHALL COMPLY WITH STATE AND) LOCAL CODES 6ENERAVLLY, SEPARATE DOUBLE J015T THETHIGKNE55 OF WALL ABOVE.T HALL" PARALLEL To JOISTS FRAME DOUBLE JOIST AS PER SUB ", FOUND. FOUNDATION THK. THICK AND ORDINANCES. MEET THE PROVISIONS OF ASTM G36 SPECIFICATION FOR GYPSUM 4. FOOTINGS TO REST A MIN. OF 4-O BELOW GRADE, UNLE55 FLOOR SHALL NEVER EXCEED A 16" SPAN. WALLBOARD A5TM 031 SPECIFICATION FOR GYPSUM LATH, OR A5TM 0111 OTHERWISE NOTED Ib. THE CONTRACTOR SHOULD FULLY GUARANTEE H15 WORK SAND THE WORK OF 5. WALLS TO BE POURED CONCRETE OF SIZE SHOWN ON DRAWINGS, U.O.N. �0- SPECIFICATION FOR GYPSUM SHEATHING BOARD. FRGE FLOOD RESISTANTGONSTRUGTION ELEVATION T.O.W. TOP OF WALL ^ THE 5UB-CONTRACTORS FOR A PERIOD OF AT LEAST ONE YEAR AFTER 11. AT ROUGH OPENINGS PROVIDE ALL APPLICABLE NAILING AND STRAPPING COMPLETION OF PROJECT. A5 PER PAGE 6-005. 1.1. HARDBOARD: HARDBOARD USED IN A STRUCTURAL APPLICATION SHALL FR. FRAME I Tr 11 TREAD MEET THE PROVISIONS OF AN51/AHA AI35.4 BASIC HARDBOARD OF b. NO BACK FILL SHALL BE PL.AGED AGAINST FOUNDATION WALLS -11 20. "P.T." 5PEGIFIE5 PRESSURE PRESERVATIVELY TREATED LUMBER IN AN51/AHA AL55.6 HARDBOARD 51DIN6. UNTIL I� TIER OF FRAMING IS IIN PLACE. FRPR. FIREPROOF TYP. TYPICAL ___1 Qm (D AI"l THE CONTRACTOR SHALL INDEMNIFY ;AND HOLD EMPLOHARMLYEES F THE OWNER, ACCORDANCE w/AWPA 022; WHERE DRILLING AND/OR GUTTING OCCURS, FIELD Q AOAINS ALL CINEER, AND THEIR A055E:5 AND EMPLOYEES FROM AND TREAT LUMBER w/ COPPER NAPTHENATE WHICH SHALL CONTAIN 2% COPPER I.8 5TRUGTURAL PANELS: 1. FOOTINGS TO BE POURED CONCRETE OF SIZE SHOWN ON DRAWINGS. FTC. FOOTING U.O.N. UNLE55 OTHERWISE NOTED AGAINST ALL CLAIMS, DAMAGES, LOSSEES AND EXPENSES, INIGLUDIN6 ATTORNEYS FEES ARISING OUT OF OR r%ESULTIN6 FROM THE; PERFORMANCE OF METAL BY REPEATED BRUSHING, DIPPING, OR SOAKING UNTIL THE WOOD THE WORK PROVIDED THAT ANY 5UGH CLAIM, DAMAGE, LOSS OR EXPENSE (A) ABSORBS NO MORE. ALSO, FOR HARDWARE USED WITH P.T. LUMBER, 1.8.1. PLYWOOD: PLYWOOD USED IN STRUCTURAL APPLICATIONS SHALL 8. ALL OPENINGS FOR BEAM P'OGKETS, UTILITIES, ETC. TO BE FILLED GYP. BD. GYPSUM BOARD VERT. VERTICAL CONTRACTOR IS TO INSTALL HARDWARE THAT 15 SPECIFIED BY P.T. LUMBER MEET THE PROVISIONS OF U.S. DEPARTMENT OF COMMERCE SOLID WITH CONCRETE. 15 ATTRIBUTABLE T BODILY INJURY, IBLSICE RO DISEASE HE DEATH HE TO MANUFACTURER SUCH AS: HANGERS, NAILS, 5GREW5, FLASHING, ANCHOR BOLTS, VOLUNTARY PRODUCT STANDARD I (PS 1) CONSTRUCTION AND H.D. 1 HOLD DOWN V.I.F. VERIFY IN FIELD INJURY TO OR DESTRUCTION OF TANGIB!_E PROPERTY (OTHER THAN THE WORK INDUSTRIAL PLYWOOD, U.S. DEPARTMENT OF COMMERCE VOLUNTARY q• ANCHOR BOLTS SHALL BE Ii`� ACCORDANCE WITH PAGE G-003. ITSELF INGLUDIN6 THE L055 OR USE RE5ULTINC THEREFROM)). (5) I5 CAUSED IN ETC. FOR LOCATIONS SUCH AS: LEDGER BD., SILL PLATE, DECK CONSTRUCTION, WHOLE OR IN PART BY ANY NEOL16ENT ACT OR OMISSION O)F THE ETC. ANY REFERENCES TO GGA ARE TO REPLACED WITH P.T. PRODUCT STANDARD 2 (P52) PERFORMANCE STANDARD FOR 10. ALL CONCRETE TO HAVE AIN ULTIMATE COMPRESSIVE STRENGTH AT 28 I HDR HEADER W/ WITH CONTRACTWOOD-BA5ED STRUCTURAL- USE PANELS, APPLICABLE CODE EMPLOYED B ANY SUB THEM, OR AN ANYONE DIRECTLY T5, INDIRECTLY 21. LVL (LAMINATED VENEER LUMBER) DENOTES EITHER OF THE FOLLOWING: EVALUATION REPORTS. DAYS OF 4,000 P.S.I., U.O.N. HNGR � HAN6ER ND. WOOD EMPLOYED BY ANY OF THEM, OR ANYONE FOR WHOSE AGTS� ANY OF THEM MAY A. WEYERHAEUSER TRUS JOIST 2.OE MIGROLLAM LVL BE LIABLE REOARDLE55 OF WHETHER OR NOT IT 15 CAUSED> IN PART BY A 11. GONG. 5LA55 TO REST ON "IN. OF 6" FINE 6RAVEL OR SAND WITH PARTY INDEMNIFIED HEREUNDER. B. OEORGIA PACIFIC 2.OE 6-P LAM LVL 1.8.2. ORIENTED-STRAND BOARD (055), WAFERBOARD ORIENTED-STRAND b MIL. POLYETHYLENE VAPOR IBARRIER UNDER HOR. HORIZONTAL ZR ZONING RESOLUTION PSL (PARALLEL STRAND LUMBER) DENOTES: BOARD OR WAFERBOARD USED IN STRUCTURAL IONS SHALL MEET 1,5. ALL MATERIALS, ASSEMBLIES, AND METHOD OF CON5TRUIGTION INGLUDIN6 A. WEYERHAEUSER TRU5 JOIST 2.2E PARALLAM PSL THE PROVISIONS OF U.S. DEPARTMENT OF COMMERCE VOLUNTARY 12. COPPER FLASH ALL JOINTS: WHERE SLAB ABUTS FRAMIN6. BUT NOT LIMITED TO FORM-WORK, BLOCK-WORK, FRAMING, MIAILIN&, PLACING ALL TO BE INSTALLED AS PER MANU. SPEG.'s PRODUCT STANDARD 2 (P52) PERFORMANCE VOLUNTARY PRODUCT OF CONCRETE, ETC. ARE TO BE CAREFULLY SUPERVISED BY' THE CONTRACTOR STANDARD FOR WOOD-BA5ED STRUCTURAL- USE PANELS OR 13. BRICK VENEER TO BE ANCHORED WITH CORROSION RESISTANT TIES - TO BE SURE THEY ARE IN ACCORDANCE WITH THE DRAWINGS, SPECIFICATIONS, 22. I-JOIST FLOOR SYSTEMS SHALL BE IN ACCORDANCE WITH THE WOOD APPLICABLE CODE EVALUATION REPORTS. (1) WALL TIE PER (5) 50. FT. APPLICABLE CODES AND 600D PRACTICE. DEVIATIONS FROM THE DRAWIN65 FRAMING MATERIAL STANDARDS SECTION, THE GOVERNING BUILDING GORE, INSULATION $ FENESTRATION REOU I RD1 ENTS AND ANY ADDITIONAL REQUIREMENTS SET FORTH IN THE MANUFACTURER'S 1.5 3. PARTICLE BOARD: PARTICLE BOARD USED IN STRUCTURAL AND SPECIFICATIONS WILL NOT BE PERT`11TTED WITHOUT WRITTEN 14. FLASH JOINT AT BRICK LEDGE AND PROVIDE WEEP HOLES, AUTHORIZATION OF THE ARCHITEOVENOINEER. CODE EVALUATION REPORT. APPLICATIONS SHALL CONFORM TO AN51 A205.1 AND ANY MAX. 32'-O" O.G., TO DIRECT ANY CONDENSATION TO THE EXTERIOR. - REQUIREMENT5 AS SET FORTH IN THE MANUFACTURERS CODE 111. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY 5HO)P DRAWINGS 25. NOTCHES IN THE TOP OR BOTTOM EDGE OF SOLID SAWN RAFTERS SHALL EVALUATION REPORT. 15. APPLY (1) GOAT OF TAR BASED WATERPROOFING TO EXTERIOR OF FOUND. PROPOSED DESIGN CODE PRE5GRIPTIVE VALUE NEEDED, UNLE55 OTHERWISE SPECIFIED. ALL DIMENSIONS AND CONDITIONS NOT BE GUT IN THE MIDDLE ONE-THIRD OF THE RAFTER SPAN. NOTCHES IN THE FROM FOOTING TO 2" ABOVE fFIN15H GRADE. COMPONENT VALUE CITATION (PER 2020 NY5ECCG) COMPLIES PERTAINING ARE TO BE FIELD VERIFIED. OUTER THIRDS OF THE SPAN SHALL NOT EXCEED ONE-51XTH OF THE ACTUAL 1.8.4. FIBERBOARD: FIBERBOARD USED IN STRUCTURAL APPLICATIONS RAFTER DEPTH. WHERE NOTCHES ARE MADE AT SUPPORTS THEY SHALL NOT SHALL MEET THE PROVISIONS OF AN51/AHA AIc14.1 CELLULOSIC 16. NO CONCRETE OR MA5ONR1Y WORK 15 TO BE PERFORMED IN TEMPERATURES 20. CONTRACTOR TO REMOVE 4 RELOCATE AS REQUIRED AkLL EXISTING WORK EXCEED ONE-FORTH THE ACTUAL RAFTER DEPTH. BORED HOLES ARE LIMITED FIBERBOARD OR A5TM 0205 STANDARD SPECIFICATION FOR OF 40°F AND FALLING, UNLESS APPROVED BY ARGHITEGT/ENGINEER. NO a �� WHICH INTERFERES WITH NEW CONSTRUCTION IN A WORKMAN LIKE MANNER. IN DIAMETER TO ONE-THIRD THE ACTUAL RAFTER DEPTH AND THE EDGE OF THE CELLULOSIC FIBER INSULATING BOARD. CONCRETE SHALL BE PLACED ON FROZEN SURFACES. EXTERIOR (2 X4 ) R-15 CAVITY BATT MIN. R-VALUE = I5 (CAVITY) + 5 HOLE SHALL NOT BE CLOSER THAN 2 INCHES TO THE TOP OR BOTTOM EDGE5. WOOD FRAME INSULATION (CONTINUOUS) 21. ALL MATERIALS ARE TO BE INSTALLED AS PER MANUFAC:TURER'S 1.8.5. STRUCTURAL PANEL SIDING STRUCTURAL PANEL SIDING USED IN 11. NO ADDITIVES SHALL BE PILACED IN CONCRETE UNLESS SPECIFIED BY YES 24. NOTCHES IN EITHER EDGE OF STUDS SHALL NOT BE LOCATED IN THE STRUCTURAL APPLICATIONS SHALL MEET THE REQUIREMENTS OF U.S. EXTERIOR WALL R-5 CONTINUOUS RIGID PER TABLE R402.1.2 - CLIMATE SPECIFICATIONS, UNLESS NOTED OTHERI.115E. MIDDLE ONE-THIRD OF THE STUD LENGTH. NOTCHES IN THE OUTER THIRDS OF DEPARTMENT OF COMMERCE VOLUNTARY PRODUCT STANDARD I ARCHITECT/ ENGINEER. THE STUD LENGTH SHALL NOT EXCEED 25% OF THE ACTUAL DEPTH. BORED (P5- 1), THE 60VERNIN6 BUILDING CODE, AND ANY ADDITIONAL R-V 11 11ALUE INSULATION ZONE 4, NOTE (h) 22. PROVIDE FIREBLOGKIN6 AS PER NEW PORK ACCESSIBILITY STANDARDS. HOLES SHALL NOT EXCEED 40% OF THE ACTUAL STUD DEPTH AND THE EDGE REQUIREMENTS AS SET FORTH IN APPLICABLE GORE EVALUATION I8. PROVIDE BITUMINOUS JOINT'S BETWEEN 5LA85 AND FOUNDATION WALLS AND OF THE HOLE SHALL NOT BE CL05ER THAN 5/8" TO THE EDGE OF THE 5TUD. REPORTS. WHERE EVER APPLICABLE. I y�I /� *I 23. PLEASE NOTE THAT THESE PLANS ARE PROTECTED AGAINST ANY NOTCHES AND HOLES SHALL NOT OCCUR IN THE SAME GROSS-SECTION. GOMPL I�I`tG� STI"'�T�M�I`4T: UNAUTHORIZED USE UNDER FEDERAL LAW BY THE ARCHITECTURAL WORKS 2.2. FASTENERS AND CONNECTORS: ALL FASTENERS AND CONNECTORS 5HALL Iq. UNLESS OTHERWISE INDICATTED, ALL FOUNDATION FOOTINGS ARE TO BE A ll i� 1�I I I AND I GOPYRI6HT PROTECTION ACT OF IQQO (AWCPA), WHICH HAS SEVERE PENALTIES. MIN. 10 DEEP PROJECTING b (ON EACH SIDE OF THE FOUNDATION WALL. TO THE �3EST OF W KNOWLEDS E� 5EL 1 EF, ,AND PROFESSIONAL 25. FOR NEW WALLS, A PERFORATED SHEARWALL SYSTEM IS USED. THE CONFORM TO THE STANDARDS SPECIFIED IN M 2.2.1 THROUGH M 2.2.1. „ CONTRACTORS ATTENTION 15 DIRECTED TO THE APPLICABLE DETAILS, PROVIDE TWO #4 DEFORMED BAR5 CONTINUOUS IN THE FOOTING. ALL 4 THICK I y�� y�' GENERAL WIND PROTECTION CONNECTION NOTES: NOTES, AND TABLES ON PAGE 6-003 E 0-004. THE FASTENING SCHEDULE 2.2.1. BOLTS: BOLTS SHALL COMPLY WITH ANSI/ASME B 15.2.1 SQUARE AND CONCRETE 5LA55 TO HAVE bxcb ..1 10/10 WELDED WIRE REINFORCING. X)O IE I NT, 7HESE PLANS AND SPEC;I F I CATIONS ARE IN ADAPTED FROM STANDARD FOR HURRICANE RESISTANT REVIDENTIAL SPECIFIES THE REOV NAILING FOR THE 5HEATHINC (ANY NAILING HEX BOLTS AND SCREWS (INCH SERIES). 20. FOR SECOND STORY ADDITIONS, EXIST. FOUNDATIONS ARE TO BE VERIFIED C-OMPL I ANGE WITH THE 2020 NYS ENERGY GONSERY?�TI ON CONSTRUCTION;55TD 10-9a IN AND 2018 5BG HIGH WIND EDITIO WOOD FRAME SPECIFICATIONS ON THE FLOOR PLANS SHALL SUPERSEDE THE FASTENING AS IN SOLID 4 SOUND CONDITION WITH AN EXIST. FOOTING OF MIN. Ib" WIDE x 8" Z CONSTRUCTION SCHEDULE). HOEDOWNS OPERATE IN CONJUNCTION WITH THE PERFORATED 2.2.2. LAG SCREWS: LA6 SCREWS OR LA6 BOLTS SHALL COMPLY WITH ANSI/ I. A CONTINUOUS LOAD PATH BETWEEN FOOTIN65, FOUNDATION WALLS, SHEARWALL SYSTEM (INSTALL AS PER APPLICABLE DETAILS 4 MAU. 5PEC.'s). ASME BI5.2.I SQUARE AND HEX BOLTS AND SCREWS (INCH SERIES). DEEP 4 3'-O" BELOW 6RADE. GONSTRUC%TI ON CODE US I NS CHAPTER 4 [R:]. W 2 FLOORS, STUDS AND ROOF FRAMING SHALL BE PROVIDED. HOLDOWN LOCATIONS ARE SPECIFIED ON THE FOUND./FLOOR PLANS. MECHANICAL CONNECTIONS: 2.2.5. TRU55 METAL CONNECTOR PLATES: TRUSS METAL CONNECTOR PLATES 2. APPROVED GONNECTOR5, ANCHORS AND OTHER FASTENIING DEVICES NOT 26. COLUMN BEARING AS FOLLOWS: SHALL MEET THE REQUIREMENTS OF ANSI/TPI I NATIONAL DESIGN I. ALL MECHANICAL GONNEGTIIONS SPECIFIED AS "SIMPSON" MAY BE v INCLUDED IN THE STANDARD BUILDING CODE, SECTION 2B06 OF IBC SHALL WOOD POSTIN& TO BE BLOCKED 50LID TO FOUND. WALL w/ END GRAIN, STANDARD FOR METAL PLATE CONNECTED WOOD TRU55 CONSTRUCTION, SUBSTITUTED WITH AN APPROVED EQUAL PRODUCT. BE USED IN ACCORDANCE WITH MAUFACTURER'S RECOMMENDATIONS. TREATED WOOD 4 FLASHING. STEEL COLUMNS ARE TO BEAR UPON FOUND. THE GOVERNING BUILDING CODE, AND ANY ADDITIONAL REQUIREMENTS „ 2. THE SUBSTITUTION SHALL MEET ALL OF THE MINIMUM CRITERIA SPECIFIED WALL w/STEEL 5HIM5 4 A MIN. 5/4 OF NON-SHRINK GROUT. AS SET FORTH IN THE MANUFACTURERS CODE EVALUATION REPORTS. 3. METAL PLATES, CONNECTORS, SGREI^l5, BOLTS AND NAILS EXPOSED SECURE w/ (2) I/2" 4' ANCHOR BOLTS (4" LONG EXPANSION BOLTS ® BY "SIMPSON" MANUFAGTURfER. DIRECTLY TO THE WEATHER OR SUBJECT TO SALT CORROSION IN COASTAL EXIST. WALLS 4 12 LONG HOOKED BOLTS ® NEW FOUND. WALLS). FOR ANY 2.2.4. METAL CONNECTORS WHERE METAL PLATE OR STRAPPING SIZE AND T BL.E R�OI .� CLIMATIC $ GEOGRAPHIC DE51ON CRITERIA w &ACE ARE SPECIFIED, MINIMUM A5TM A653, STRUCTURAL QUALITY, „AREAS SHALL BE STAINLESS STEEL OR HOT DIPPED 6AlLVANIZED. 3. ALL LOADING GAPAGITIES 'SHALL MATCH EXACTLY OR EXCEED VALUES POSTING ® G.M.U. WALL SEE PLAN FOR REQUIRED REINFORCING (® MIN. I6 GRADE 33 STEEL SHALL BE USED. OTHER METAL CONNECTORS SHALL INDICATED IN SIMPSON PR.ODUGT LITERATURE. THERE MAY BE SEVERAL ALLOWABLE DEFLECTION OF STRUCTURAL MEMBERS o WIDE 3 COURSES OF SOLID BRICK MASONRY CENTERED ® POSTING, U.O.N.). MEET THE REQUIREMENTS OF THE 60VERNING BUILDING CODE AND ANY 6ROUND SNOW LOAD 25 LBS 4. WHERE WINDOWS AND DOORS INTERRUPT WOOD STRUCTURAL PANEL LOADING VALUES, CONTRACTOR SHALL CONTACT ARCHITECT IF ANY SHEATHING AND SIDING,FRAMING ANCHORS OR CONNEC'TOR5 SHALL BE HOWEVER, WHEN COLUMN OR P05TIN6 15 PART OF THE LOAD PATH FOR USE ADDITIONAL REOUIREMENT5 AS SET FORTH IN THE MANUFACTURER'S LOADING VALUES ARE LE55 THAN WHAT 15 SPECIFIED BY 'SIMPSON" PROVIDED AT THE TOP AND BOTTOM OF CRIPPLE STUDS, HEADER STUDS IN A 5HEARWALL,ALL ANCHORS MAKING AN ATTACHMENT ARE TO BE w/ CODE EVALUATION REPORTS. ALLOWABLE PROJECT: AND AT LEAST ONE STUD AT EACH SIDE OF OPENIN6. STANDARD SHEARWALL HARDWARE (w/ NOTED VALUES) 4 ANCHOR BOLTS, 4. ALL MECHANICAL CONNECTIONS SHALL BE HOT DIPPED GALVANIZED STRUCTURAL MEMBER DEFLECTION BASIC, WIND SPEED 150 MPH U.O.N. WITH TOP GAPS ® STEEL COLUMNS TO BE MIN.Y4" BENT PLATE 8" LONG 2.2.5• NAILS: NAILS SHALL COMPLY WITH ASTM F 1667 STANDARD 5. RIDGE STRAPS SHALL BE ATTACHED TO EACH PAIR OF OPPOSING w/6" R15E 4 w/(2) S/4"O BOLTS THROUGH CENTER LINE OF VERTICAL LE05 SPECIFICATION FOR DRIVEN FASTENERS: NAILS, SPIKES, AND STAPLES. 5. INSTALLATION PROCEDURES SHALL ALWAYS BE CARRIED OUT AS PER EXPOSURE CATEGORY B RAFTERS EXCEPT WHERE COLLAR TIES OF I"xb" OR 2N 4" LUMBER 15 SET 6" D15T., U.O.N. - ADDITIONAL INFO. 15 FOUND ON PASSE RAFTERS HAYING SLOPES GREATER THEN 3/12 E 6-005. MANUFACTURER 5PEGIFICA717ION5 OF THE PRODUCT BEING INSTALLED. L/18 n/�0 I Y'0 LTZ LOCATED IN UPPER THIRD OF ATTIC SPACE AND ATTACH TO EACH PAIR OF 2.2b. PNEUMATIC NAILS AND STAPLES: PNEUMATIC NAILS AND STAPLES W./NO FINISHED CEILING ATTACHED TO RAFTERS RAFTERS. 51TE WORK SHALL MEET THE REQUIREMENTS OF THE C70VERNINO BUILDING CODE 6. ALL FASTENING CRITERIA SHALL BE CARRIED OUT AS PER MANUFACTURER SEISMIC DESIGN CATEGORY B I. STAKEOUT 15 TO BE PERFORMED BY A LICENSED SURVEYOR AND ANY ADDITIONAL REQUIREMENTS AS SET FORTH IN THE SPECIFICATIONS OF THE PR.ODUGT BEING INSTALLED RESIDENCE 6. UPLIFT CONNECTORS SHALL BE PROVIDED AT EACH RAFTER SEARING 2. VERIFY ALL GIVEN DATA ON DRAWINGS. IF THERE IS A DISCREPANCY, 'S SEARING. 2. CODE EVALUATION REPORTS. INTERIOR WALLS 4 PARTITIONS H/180 1. VARIATIONS IN CONNECTOR: CONFIGURATION SHALL BE APPROVED BY WEATHERING SEVERE 1. FLOOR TO FLOOR HOLD-DOWNS TO BE PROVIDED EVERY 48„ AND EVERY RECEIVE CLARIFICATION FROM ARCHITECT/ENGINEER PRIOR TO PROCEEDING ARCHITECT. 2.2.1. SCREWS: SCREWS SHALL COMPLY WITH AN51/A5ME B I5.6.1 FLOORS 4 PLASTERED GEILIN65 1_/360 I6" WITHIN 4' OF EXTERIOR GORNERE>. WOODSGREWS (INCH SERIES). FROST LINE DEPTH 3'-O" 3. EXCAVATE AND BACK FILL FOR WORK INDICATED ON DRAWINGS. b. ALL CONNECTORS SPECIFIED AS A "SIMPSON' TOP MOUNTED BEAM ALL OTHER STRUCTURAL MEMBERS L/24� 1600 ALVAHS LANE 8. SILL PLATE TO FOUNDATION ANGHORA6E;SILL PLATE SHALL BE ANCHORED HANGER SHALL BE ALLOWEED TO BE SUBSTITUTED WITH A TOP MOUNTED TERMITE MODERATE TO HEAVY STOCKPILE TOP501L OBTAINED FROM STRIPPING DRIVEWAY AND BUILDING ASPHALT ROOFING SHINGLES TO THE FOUNDATION WITH ANCHOR E30LT5 HAYING A MINI. BOLT DIAMETER SITE. STOCKPILE ALL EXCAVATED MATERIALS. I. ALL SLOPED ROOFING SHINGLES SHALL BE GAF-GLASS-A ASPHALT ROOFING BEAM HANGER ONLY ALONG WITH SPECIFICATIONS LISTED ABOVE. CUTCHOGUE NY 11935 OF J" AND 3"x3"x�" WASHERS. A MINIMUM OF ONE ANCHOR BOLT SHALL BE SHINGLES OR APPROVED EQUAL. 6LA55 WINDOWS AND DOORS EXTERIOR WALLS W/ PLASTER OR STUCCO FINISH H/36C ICE BARRIER REQUIRED YES PROVIDED WITHIN 6 TO 12 INCHES OF EACH END OF EACH PLATE. ANCHOR 4. NEW AND EXISTING BACK FILL MATERIAL ARE TO BE FREE OF WEEDS, TREE I. ALL &LASS TO BE INSULATED LOW-E, UNLESS OTHERWISE SPECIFIED. BOLTS SHALL HAVE A MINIMUM EMBEDMENT OF 1" IN COINCRETE/MA50NRY ROOTS, ROCKS, AND DEBRIS. ALL SURPLUS MATERIAL THAT 15 UNSUITABLE 2. SHINGLES SHALL BE APPLIED OVER 15# BUILDING FELT, UNLESS OTHERWISE EXTERIOR WALLS - WIND LOADS W/BRITTLE FIN15HF-5 L/24C FOUNDATIONS. ANCHOR BOLTS SHALL BE LOCATED WITRIN 12" OR CORNERS FOR BACK FILL MATERIAL SHALL BE REMOVED FROM SITE. NOTED. ALSO, CONTRACTORS OPTION TO APPLY GAF-WEATHER-WATCH ICE 2. 6LA55 DOORS AND WINDOH5 SHALL NOT BE INSTALLED UNTIL PROPER DRAWING TITLE: AND AT SPACING NOT EXCEEDING 4' ON CENTER. AND WATER BARRIER FROM EDGE OF EAVE TO 24" IN51DE EXTERIOR WALL CLEARANCES ARE PROVIDED., 5. PROTECT TREES WITHIN EIGHT FEET OF THE BUILDING. LINE. 4 24" FROM ALL VALLEYS, AND ROOF FLASHING CONDITIONS. EXTERIOR WALLS - WIND LOADS W/FLEXIBLE FINISHES L/120 GENERAL NOTES 3. ALL SLIDING 6LA55 DOORS, SKYLIGHTS, AND ANY 6LA55 UNIT INSTALLED 3. PROVIDE FLASHING NECESSARY FOR WATER 716HT AND WEATHERPROOF WITHIN 18" OF FINISHED FLOOR' SHALL BE OF INSULATED TEMPERED GLASS, ENERGY TABLE CODES AND REFERENCE STANDARD: UNLE55 OTHERWISE NOTED. I. ALL NEW WORK PERFORMED SHALL CONFORM TO THE 2020 NEW YORK GONSTRucT1oN.ELECTRICAL: STRUCTURAL DESIGN CHARTS STATE BUILDING CODE, 2020 NEW YORK STATE RESIDENTIAL CODE, 2020 4. ALL 6LA55 UNITS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH NEW YORK STATE PROPERTY MAINTENANCE CODE, AND 20,20 NEW YORK 1• ALL NEWLY INSTALLED ELECTRICAL WORK OR APf'LIANES SHALL CONFORM 4. ROOFING IS TO BE APPLIED IN STRICT ACCORDANCE WITH MANUFACTURERS MANUFACTURER'S SPECIFICATIONS. STATE ENERGY CONSERVATION CONSTRUCTION GORE. TO 2011 NATIONAL ELECTRIC GORE, NFPA 10 AND 2020 N NEW PORK STATE SPECIFICATIONS. ENERGY CONSERVATION CONSTRUCTION GORE. 5. ALL WINDOWS TO BE GAULK:ED AND SEALED AS PER NEW YORK STATE STRUCTURAL. DESIGN LOADS 2. REFERENCE STANDARD USED FOR ALL WOOD FRAMING, 5. NAILING OF ROOFING SHALL BE TO GORE.CONNECTIONS OF 2. CONTRACTOR WILL FURNISH A FIRE UNDERWRITER5 CERTIFICATE UPON ENERGY CONSERVATION CONSTTRUCTION CODE. WOOD FRAMING, AND CONNECTION TO FOUNDATION - 2015 WOOD FRAME COMPLETION OF WORK. 6. CORROSION RESISTANT 11 6A6E ROOFING NAILS AND I6 6A6E STAPLES AREF PAGE: CONSTRUCTION MANUAL BY THE AMERICAN FOREST 4 PAPER ASSOCIATION 6. PROVIDE FLASHING PANS UNDER ALL SLIDING 6LA55 DOORS, WINDOWS,OR USE LIVE LOAD DEAD LOAD (AF4PA) AMERIGAN WOOD COUNCIL (AWC)' 3. SMOKE DETECTORS, IN CONFORMANCE WITH NFPA12: PERMITTED ANY OTHER TYPE OF 6LA55 UINIT WHEN WITHIN b" OF AN EXTERIOR SURFACE. 3. ALL PLUMBING WORK SHALL CONFORM TO THE 2020 NEIW YORK 5TATE - GENERALLY, VERIFY OR PROVIDE HARD WIRED 1. PROVIDE (2) LAYERS OF 15# ASPHALT BUILDING FELT UNDERLAYMENT FOR T ALL EXTERIOR DOORS ARE TO BE WEATHERED STRIPPED AND PROVIDE ALL EXTERIOR BALCONIES 40 psf 15 psf G-002m00 SMOKE DETECTORS w/ BATTERY BACK-UP IN: 2:12 PITCHES TO 4:12 PITCHES PLUMBING GORE. SCREENS AND HARDWARE NEC:.ESSARY FOR PROPER FUNCTION OF SUCH UNITS. DECKS 40 psf 15 psf 4. ALL MECHANICAL WORK SHALL CONFORM TO THE 2020 NEW YORK STATE A. EACH SLEEPING ROOM 5. ASPHALT SHINGLES SHALL BE TESTED TO DETERMINE THE RE515TANCE OF 8. ALL 6LA55 I5 TO BE FREE OF SCRATCHES AND IMPERFECTIONS. 6LA55 MECHANICAL GORE AND 2020 NEW YORK STATE FUEL GAS CODE. B. OUTSIDE OF EACH SEPARATE SLEEPING THE SEALANT TO UPLIFT FORGES USING A5TM D 6551. SHOULD BE GUARANTEED BY TfHE MANUFACTURER FOR A PERIOD OF 5 YEARS. PA55ENOER VEHICLE GARAGES 50 sf AS PER PLAN 5. ALL ELECTRICAL WORK SHALL CONFORM TO 2011 NATIONAL ELECTRIC AREA IN THE IMMEDIATE VICINITY OF Q. ALL WINDOWS TO BE &LO5*L WINDOWS SYSTEM. IF CONTRACTOR 15 TO UNINHABITABLE ATTICS WITHOUT 5TORA5E DATE: 09/25/24 2 OF 7 CODE, NFPA 10 AND 2020 NEW YORK STATE ENERGY CONSERVATION THE BEDROOMS (GENERALLY THE HALLWAY) MECHANICAL. FUEL OAS: SUBSTITUTE WITH ANOTHER WINIDOW MANUFACTURER, IT IS THE RESPONSIBILITY (MAX CLEAR HOT < 42") 10 psf 15 psf CONSTRUCTION CODE. OF THE CONTRACTOR TO VERIJFY THAT THE CHARACTERISTICS OF THE WINDOW G. EVERY LEVEL OF DWELLING UNINHABITABLE ATTICS WITH STORAGE I. MECHANICAL AND FUEL GAS SYSTEMS SHALL COMPLY w R./ THE MATCH THE CHAACTERISTIG5i OF THE GLOBAL WINDOWS SYSTEM WINDOW GYPSUM WALL BOARD (BASEMENT, FIRST FLOOR, 4 SECOND FLOOR,ETC) NY5 MECHANICAL CODE AND FUEL OAS CODE SPECIFIED. THE CHARACTERISTICS ARE AS FOLLOWS, BUT NOT LIMITED TO: (MAX CLEAR HOT > 42") 20 psf 15 psf I. GYPSUM WALL BOARD SYSTEMS SHALL BE OF A TAPE JOINT AND JOINT DESIGN PRESSURE, ROUGH OPENING, U-FACTOR, LIGHT AREA, VENT AREA, AND HABITABLE ATTICS 4 COMPOUND METHOD. 2. ALL MECHANICAL SYSTEMS, APPLIANCES, 4 EQUIPMENT SHALL BE LISTED, EORE55 R.EQUIREMENT5. ATTICS SERVED BY FIXED STAIRS 30 psf 15 psf 2. ALL GYPSUM BOARD SHALL BE 1/2" ON WALLS AND CEIL.IN6, UNLE55 INSULATION LABELED, 4 INSTALLED IN ACCORDANCE w/ MANUFACTURER'S SPEC.'S 4 CODE. OTHERWISE NOTED. HATER RESISTANT (W.R.) AT BATHROOMS AND WHERE 1. ALL EXTERIOR HALLS AND ROOFS SHALL BE INSULATED WITH FOIL FACED 10. WINDOWS IN TUB/SHOWER EiNGLOSURES AND WITHIN STAIRWAYS SHALL BE ROOMS OTHER THAN SLEEPING ROOMS 40 psf I5 psf DEEMED APPLICABLE. FIBERGLASS BATT INSULATION BY JOHN MANVILLE OR APPROVED EQUAL. 3. ALL FUEL OAS SPACE HEATING APPLIANCES IN RESIDENTIAL BUILDINGS TEMPERED GLAS5. "" w.`.�,,•`' -' 11 SHALL BE EQUIPPED w/ FLAME SAFEGUARD DEVICE WHICH SHUTS OFF THE FUEL II. EXTERIOR GLAZING SHALL 83E PROTECTED FROM WINDBORNE DEBRIS. ' ' ' 4 . FOIL TO BE PLACED TOWARD WARM SIDE. SLEEPING ROOMS 30 psf IS sf 3. 5/8", ONE HOUR RATED, TYPE 'X' GYPSUM BOARD ON GEIILINC AND WALLS SUPPLY TO THE BURNER WHEN THE FLAME OR PILOT LIGHT IS EXTINGUISHED. GLAZED OPENING PROTEGTIOt`V SHALL MEET THE REQUIREMENTS OF THE LARGE P P :"; - ", (WHERE APPLICABLE) AT HEAT PRODUCING EQUIPMENT TO EXTEND THREE FEET 2• PROVIDE 2" R-10 RI61D FOAM INSULATION FOR EXTERIOR FOUNDATION MISSILE TEST OF ASTM E1a96 SAND ASTM EI886 AS MODIFIED BY 2020 NY5 BC 4. SUPPLY 4 RETURN DUCTS OR PORTIONS THEREOF NOT LOCATED SECTION 501.2.1.2.1. GARAGE DOOR &LAZED OPENING PROTECTION SHALL MEET STAIRS 40 psf 15 psf , IN EACH DIRECTION BEYOND THE UNIT(5,1. ALSO AT HEAT PRODUCING WALLS FROM 6" BELOW GRADE TO 24" BELOW GRADE IF DESIRED BY - ,, EQUIPMENT, CONCRETE FLOOR OR IF PLACED ON WOOD FRAME, INSTALL CONTRACTOR OR OWNER. CARE SHOULD BE TAKEN NOT TO DAMAGE COMPLETELY INSIDE THE BUILDING THERMAL ENVELOPE SHALL BE INSULATED THE REQUIREMENTS OF AN AFfFROVED IMPACT-RESISTANT STANDARD OR CONCRETE PANELS OF 5/8" THICKNESS MINIMUM. FOUNDATION WATERPROOFING. TO AN R-VALUE OF AT LEAST (NY5 EGG R403.3): AN51/DASMA 115. GUARDRAILS AND HANDRAILS 200 psf 15 psf - 12. AS AN ALTERNATIVE TO NOTE #II ABOVE, WOOD STRUCTURAL PANELS WITH I' p 4. FINISH JOINTS, J-BEADS, NAIL PIMPLES, CORNERS, AND EVOE5 SHALL BE 3. GENERALLY, UNLESS NOTED OTHERWISE, INSULATE AS FOLLOWS: DUCTS 3",P 4 GREATER, LOCATED IN ATTIC,: R-8 A THICKNESS OF NOT LESS THJAN 9" AND A SPAN OF NOT MORE THAN 8' 5HALL - - • , TAPED AND RECEIVE THREE GOATS OF JOINT COMPOUND. ALLOW 24 HOURS - (" R-30 FOR FLAT CEILINGS DUCTS UNDER 3"O, LOCATED IN ATTIC,: R-6 BE PERMITTED AS GLAZING PRROTEGTION. PANELS SHALL BE PRECUT AND TO DRY BETWEEN GOATS. FINAL GOAT TO BE SANDED SMOOTH. - 8.25 R-50C FOR VAULTED AND CATHEDRAL GEILIN65 DUCTS 3"O 4 GREATER, OTHER PORTION OF BUILDING: R-6 ATTACHED TO THE FRAMING 5BURROUNDIN6 THE OPENING. PANELS SHALL BE ROOF LOADING (LIVE = &ROUND SNOW LOAD) 25 psf 15 psf ,. 11, - - 3.5" R-13 FOR 2"x4" WALL CONSTRUCTION DUCTS UNDER 3"O, OTHER PORTIONS OF BUILDING: R-4.2 PREDRILLED AND SECURED WIITH THE ATTACHMENT HARDWARE PROVIDED AS ,. . . 5. METAL CORNER BEAD TO BE USED ON ALL OUTSIDE CORNERS AND AROUND - 5.25" R-21 FOR 2"x6" WALL CONSTRUCTION PER THE ANGHORA6E METHOD) SELECTED IN ACCORDANCE WITH TABLE "' ALL OPENINGS. - 5.25 R-21 FOR FLOORS R301.2.1.2. ATTACHMENT HARDWARE SHALL BE PERMANENT CORROSION-RESISTANT AND Ti HE ANCHORS SHALL BE PERMANENTLY INSTALLED ALL STRUCTURAL DESIGN CONSIDERATIONS ARE IN CONFORMANCE WITH b. FASTEN GYPSUM BOARD AS PER FASTENING SCHEDULE ON PAGE 6-003. , ON THE BUILDING. ASCE 1-16 (MINIMUM DESIGN LOADS FOR BUILDIN65 AND OTHER STRUCTURES) I OENERAL 5 'M 50L f<E*"' : _ EXISTING TO BE DEMOLISHED NEW PARTIAL HEIGHT WOOD FRAME (L.G. STL. Q EXISTING TO REMAIN WHEN APPLICABLE) 4'-II" I5'-Q"— 0 LLJ NEW WOOD FRAME (L.G. NEW FOUNDATION WALL $N LLI CD STL. WHEN APPLIGAB!'_E) —� 6" 6'-I I" 8'-4' (� NEW I-HR FIRE RATED ® MIN. (2) 2"x4" STRUCTURAL L WOOD FRAME (L.G. 5'TL• POST FOR 4 WALLS WHEN APPLICABLE) (MIN. (2) 2"xb" STRUCTURAL POST FOR b" WALLS), U.O.N. _ 2 ` _— _' _•_ _ I NEW 2-HR FIRE RATED — WOOD FRAME (L.G. STL. m O — — — — — — — — — — 4 ' MECHANICAL SYSTEMS: _ m a0 N WHEN APPLICABLE) I. IN5TALL/REROUTE ALL EQUIPMENT AS PER MANU. SPEC.'S — — — — — — 2.MAINTAIN 50"x5O" CLEARANCE IN FRONT OF MECHANICAL — — — UNITS AS PER NY5 MG 506.1 DBL. F.J. x 5.MAINTAIN ALL APPLICABLE VENTING CLEARANCES — — w REQUIRED PER NY5 MG 804. I I I .• I53": ---4'-6"— I'-5. o 4•IF APPLICABLE,EQUIPMENT TO EXIST. P11P N6SAS RE D.ROUTE, 4 RECONNECT PROPOSED P01 HOT 15" SPA Q O d TYPICAL MECHANICAL AREA NOTES: I X � - I. FOR WD. FR. FLOOR - PROVIDE I/2" GONG. BD. BY cV� L) 4 I `' 460IS.S.F. BENCH DEMOLITION NOTE: "DUROCK" (OR EQUA `r Q t- PROVIDE SHORING AND SUPPORT TO ALL AFFEG-17ED 2. FOR WD. FR. WALLS - PROVIDE (1) LAYER OF 5/8" r I NEW 2"x8" SPA STRUCTURAL MEMBERS PRIOR TO THE GOMMENGE MENT 5. WHEN OYP. BD. UL U505 (OMIT ON CONC. INSTALL FURNACE/BOILER AS PER MANU) OF ANY DEMOLITION OR GO I I m Q ® I(" O.G. I A-401 �CONSTRUCTION. �- SPEC.s AND AS PER NY5 MECH. AND FUEL OAS CODE 4. WHEN EXIST.,MECH. EQUIP. SHALL BE VERIFIED THAT L O I TPL. F.J. I I — — — — J IT CONFORMS TO NYS MECH. AND FUEL OAS CODE in PROV. HANOER5 - 5. COMB. AIR VOLUME AS PER MANU. SPEC.'S - PROVIDE REMOVE BILGO FRESH AIR INTAKE FROM EXTERIOR — - DOORS BUT BILCO 6. MAINTAIN OR PROVIDE FURNACE/BOILER ELECTRICAL I DBL. F.J. (4 U - -0 STAIRS TO REMAIN; EMERGENCY SHUT OFF SWITCH �J ' ` `„J PROVIDE NEW RELOCATE -i. FOR 6A5 SERVICE,PROVIDE 6A5 SHUT OFF SWITCH �i - O - O ' V , REMOVE FLUE ACCESS HATCH r----i—-- SHOWER OUTDOOR 8. LOCATE MECH. EQUIP. TO ALLOW FOR PROPER I O d� Q K \11'117HIN WOOD DECK I CLEARANCES AS PER GORE N ® it ® n 1 REMOVE AND I __ q. PROVIDE 5" FLOOR DRAIN IF REO'D BY EQUIPMENT b EXIST. STAIRS ? PROP. DECK 2' X 5' �f REPLACE W/WIDER I rl�----�h CONNECT TO SANITARY SYSTEM AS PER NY5 I I I I 11 I � 0 W/NEW HIDDEN Q AGGE55 HATCH .-�� WINDOW I I I / I PLUMBING CODE I H BILCO ACCESS t; 10.APPLIANCES JOINED THROUGH A COMMON NATURAL IL I DRAFT VENTING SYSTEM SHALL COMPLY WITH ALL 4 HATCH n I O SECTIONS OF 2020 NY5 RC 62421. ---- REMOVE SHONER EXIST. UP _ V ----� �_ REMOVE EXIST. REPLACE 6A5 BATHROOM METER O ��--��----- O f{-,�I FIXTURES REMOVE AND 1 II REPLACE W/WIDER III I 71 ( / REMOVE WINDOW o� II AND WALL FOR �� EXIST. BATH WINDOW I_++ 11 — DOOR OPENING f\� 34.1 SF. EXIST. EXIST. GAS REMOVE WALL RELOCATED y FILTER p HATER �H 8 BOILER I III EXIST. KITCHEN DOOR _ / FOR DOOR BOILER m 1 210.0 5F. ��_))� OPENIN6 VENT EXIST. UNEXCAVATED I REMOVE ALL -___ AREA I KITCHEN GABS AND 2,_6, ___= T 7 I APPLIANCES 6 1 L \ BASEMENT ------� REMOVE 4 I REPLACE DOOR DN I88.9 5F. I ------------iI / EXIST. 2X8 F.J. ® I6 O.G. V.I.F. EXIST. LAUNDRY EXIST. EXIST. ELEG. ROOM MUDROOM PANEL 55.4 5F. 42.4 5F. EXIST. UP11 ELEG. EX I ST. -- METER AGGE55 OPENING EXIST. DINING — ROOM _ 165 SF Z LLI O — V EXIST. LIVING ROOM 400 5F EXIST. GL EXIST. LU 11.3 5F. CRAWLSPAGE Q EXIST' 2X8 F.J. PROJECT: ® 16" O.G. V.I.F. EXIST. M 0 LTZ ILO SF. RESIDE EXIST. DEN s . 1600 ALMS LA CUTCHOGUE, NY 1 DRAWING TITLE: EXIST. PROPOSED DEMOLITION I 6.1r 5F. PROPOSED FOUNCATION EXIST. COVERED PAGE: PORCH 160.0 SF. A_�� . ❑ ❑ ❑ ❑ DATE: 09/25/24 I 3 L I` RCFOSEI� I7EMOL I TI ON F I R5T FLOOR PLAN fi�fi�OFOSEI7 FOUNDATION PLAN t.I SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" �' NAL SNTOOO'��5OL <E %r : ALL NEW WINDOWS SHALL BE GLOBAL WINDOWS SYSTEMS; INSTALL AS PER MANU. SPEC.'s. ** SEE DOOR SCHEDULE FOR ALL GLASS DOORS FROM SAME MANUFACTURER * FINAL DIMENSIONS FOR FRAMING OF WINDOWS TO BE PROVIDED BY WINDOW MANUFACTURER NEW PARTIAL HEIGHT �` CONTRACTOR TO VERIFY MANUFACTURER DIMENSION WIDTHS FOR ALL MULLED WINDOW ..S 0 EXISTING TO BE DEMOLISHED tlllllz� WOOD FRAME (L.G. STL. Q EXISTING TO REMAIN WHEN APPLICABLE) WINDOW CHART W NEW WOOD FRAME (L.G. NEW FOUNDATION WALL EGRESS CLEAR LIGHT VENT WINDOW DIMENSION OPENING PROV. PROV. '� o 5TL. WHEN APPLICABLE) TAG COUNT TYPE MODEL # WIDTH REOV: 20" TEMP. PER UNIT PER UNIT NOTES Q cy) N NEW I-HR FIRE RATED ® MIN. (2) 2"x4" STRUCTURAL HEIGHT READ: 24" WIDTH HEIGHT (S.F.) (S.F.) � WOOD FRAME (L.G. STL. P05T FOR 4" WALLS GWS OPEN REQ'D: 5.'1 S.F. ? b7 WHEN APPL.IGABLE) (MIN. (2) 2 xb STRUCTURAL A 4 AWNING SLIMLINE 2'-6 3'-2" 4.21 2.48 MULLED .� P05T FOR 6 WALL5), U.O.N. NEW 2-HR (FIRE RATED 4 TRANSOM 5L MLiNE 77i4 I-oilMULLED O N Z o OHS WOOD FRAME (L.G. STL. i WHEN APPLICABLE) 2 TRANSOM SL MLINE 3-O I'-O MULLED � X N _J 2 O 4-+ 1 O o m , co FLOOR PLAN 'NOTES DOOR SCHEDULE CV C6 Q 0a � o DOOR NOTE: F_ DOOR MATERIAL O I. INSTALL NEW INTERIOR DOORS WHEN GALLED OUT 15'-9" FIRE RATING TAG DESCRIPTION MANUFACTURER p 45 MIN. RATED NOTES ` ON PLANS BY 'JEER-WEN' (OR. EQUAL). �` WIDTH HEIGHT W SELF-CLOSING W 2.INSTALL NEW EXTERIOR DOOFzS WHEN GALLED OU1f ON PLANS BY 'THERMATRU' (OR EQUAL). 5.NOTE DOES NOT INDICATE EACH NEW DOOR ® ® Q IU PROPOSED;SEE DE516NATION5 d DOOR 50HEDULIE. - in 4.PLACE DOORS 4" MIN. FROM PERPENDICULAR WALL5,U.O.N. m FIRST FLOOR 5. INSTALL A5 PER MANU SPEG.'s NEH - - - J 77 4_J 70 6.PROVIDE (2) 2"xIO" HDR.,U.O.N. °a'-I" 101 51NGLE SWING JELD-WEN WINDOW NOTE: -�-0: PROP. B WOOD GLOBAL OUTSWING O I. ALL NEW WINDOWS 4 DOORS SHALL BE GLOBAL HINDOW POOL GOPIN6 TO 102 DOUBLE SWING WINDOW 6'-O" (o'-8" • • FRENCH n SYSTEMS CASEMENT,DOUBLE-HUNG, OR 6LIDING (SAS PROPOSED MATCH DECK SYSTEMS tjJ NOTED). INSTALL A5 PER MANU. 5PEC.'S. 2.NOTE DOES NOT INDICATE EACH NEW WINDO PROPOSED; HOT TUB _ DOORS SEE DESIGNATION5 $ WINDOW SCHEDULE. W 49 S.F. O 103 BULKHEAD HIDDEN LUGIGOLD 4'-5" 5'-6" �i END HINGE 5.FOR SUBSTITUTIONS, SEE NOTE #q IN 6LA55 WINDCOWS GUNITE d r DOOR LL AND DOORS" ON PAGE 6-002. Q IN-D 104 DOUBLE SWING WINDOW 5'-O" 6'-8" EGK GLOBAL • 4.ALL CASEMENT WINDOW5 TO HAVE 5TRAI6HT ARwI HINGE. 3 • • 5. ALL DOUBLE HUNG WINDOWS TO BE TILT WASH S SYSTEMS b.IN GENERAL, TEMP. 5,L. SHALL. BE PROVIDED: Z V b.1. FOR ALL SKYLIGHTS �$ OPERABLE PANELS OF p Q v O SWINGING, SLIDING, d BIFOLD DOORS IVtu 6.2. WITHIN IS" OF F.F. O 6.5. WITHIN 24" OF A DOOR O 6.4. WITHIN STAIRWAYS d 1�11THIN 56" OF A LANIDIN6 < ' PROP. DECK 2' X 5' 6.5. WITHIN TUB/SHOWER ENCLOSURES7 PROPOSED ACCESS HATCH •!n 6.6. SEE AL50 GENERAL NOTES ON PAGE 6-002 DECK s BELOW V J -1. WINDOW FALL PROTECTION SHALL BE PROVIDED IPER I I 283.5 S.F. NY5 R312.2 FOR OPERABLE PgINDOW5 WITH SILL HIEICHTS LESS THAN 24" ABOVE F.F., THAT ARE MORE THAN "72" RELOCATED ABOVE 6ADE OR THE ADJACENT SURFACE AT THE 1 ( 103 OUTDOOR SHOOWERVER R 20 BUILDING EXTERIOR. \ _ (OPEN P.T.ABOVE); EGRESS NOTE: 40-�-� ® r 4 x4 .T POSTS WOOD PANEL SIDINGN IN COMPLIANCE WITH NEW YORK. STATE BUILDING CODE,SECTION R510.2.1;THE FOLLOWING MEANS OF E6RE5S SHALL BE FOLLOWED: I V If NET CLEAR OPENINO........... 5.4 S.F. (2) 5" L L HDR. 102 O 0 NET CLEAR HEIGHT............... 24" MINIMUM A NET CLEAR WIDTH................. 20" MINIMUM m 0 2 p O 5 EXIST. 2X5 RAFTERS • NEW FLOOR: • -r F MODIFIED ® 16" O.G. O 1. NEW J" PLYWOOD SUBFLOOR BENEATH (GLUE d 5C:REW); A KITCHEN D Q BATH 3X8 COLLAR TIES SCREW PERIMETER OF 5HEATHING 6" O.G. k 12" O..G. 0 INTERIOR. X r N 2.NEW R FINISHED FLOOR,TO MATCH EXISTING .2 SF IK BATHROOM -73 XIST. iv 2 ry p I • EXIST. 62.1 5F. NEW BASEMENT DOOR: 101 O I. NEW HIDDEN ACCESS DOOR W 200 5F. WITHIN DECK OVER E;XI5TIN6 - - BEDROOM BILGO STAIRS. 6" 2.INSTALL LUCIGOLD BULKHEAD DOORS ( OR APPROVED O O ! O EQUAL) o 0 3.INSTALL AS PER MANU 5PEG.'s � iv EXISTING EGRESS; 5.8 EXISTING FLOOR: � O EXIST. S.F. CLEAR OPEN; 27" O I. EXISTING FLOOR TO REMAIN �D �j 10 °N CLEAR HEIGHT; 51" CLEAR WIDTH 4'-0" ST. LAUNIDRY EXIST. 2X6 C.J. -�' Lu EXIST. ® Ib O.G. W/4-1/4 EXIST. ROOM T61 FLOOR JOISTS 515TERED D MUDROOM 01-1 33.4 SF. EXIST. 42.4 5F. 15.1 sF. UP EXIST. z CL. "' 14.6 5F. 2 O C) EXIST. 54.5 SF. EXIST. ui CL. >< EXIST. DINING 34.3 Sr-. 65 5FM - x PROJECT: _ 15.b SF. °® r EXIT. MOLTZ D ® RESIDENCE ILI X N 4" EXIST. EXIST. LIVING 2'-2 CL. ROOM 1600 ALVAHS LANE 11.3 5F. 400 5F EXISTING EGRESS; EXISTING EGRESS; 7.0 S.F. CLEAR 7.0 S.F. CLEAR CUTCHOGUE NY 11935 OPEN; 24.75 OPEN; 24.15 CLEAR HEIGHT; 41" - CLEAR HEIGHT; 41" \\-EXISTINC7AC CONDENSER CLEAR WIDTH ® CLEAR WIDTH DRAWING TITLE: EXIST. r PROPOSED FIRST FLOOR PLAN EX 1ST. BEDROOM i0 GL. EXIST. 159 SF. 11.o SF. BATHROOM . EXIST. PROPOSED SECOND FLOOR PLAN 63.1 SF. BEDROOM s 1'70 5F. i REMOVE 3 EXIST. REPLACE ° N B X v�, s PAGE: 103 5F. EXIST. 2X6 G.J. ® I6" O.G. W/ 515T EXIST. 2X6 RAFTERS PROP. 4' EXIST. 2X6 RAFTERS 1 FLOOR JOISTS 515TERED ® I6" O.G. A-102m00 CABINET EXIST. 2X6 G.J. EXIST. 2X6 G.J. EX15T. ® I6" O.G. ® I6" O.G. DATE: 09/25/24 4 OF 7 EXIST. COVERED PORCH 160.0 5F. ❑ ❑ ❑ ❑ j i RCF05E�) F I R5T FLOOR FLAN SEC CNI7 FLOOR PLAN SCALE: 1/4" = I'-O" SCALE: 1/4" = I'-O" ELE1/,ATION NOTES NEN DIRECT VENT FOR EXIST. MEGH UNIT: OI NEW WOOD FRAME DECK b STAIR O INSTALL NEW VENT AS PER MANU. SPEC.'S FOR a. EXISTING 6A5 BOILER. IN FULL CONFORMANCE W Q VENTING CLEARANCES REOUIRED PER NYS MG 804. SEE AL50 NOTE ® FLOOR PLANS. LLJ O NEW WINDOWS $ DOOR Lli HATCHED AREAS INDICATE NEN SIDING TO MATCH J EXISTING (TYP.) cc O (y) O3 NEW 2" AZEK WINDOW TRIM Q +-' (\j O Lr) O O � O REBUILT OUTDOOR SHOWER, OPEN TO A50VE L T- O C N z 0 O5 NEW HORIZONTAL HOOD SCREEN UNDER DECK a. 'co ul I c 2 X =3 N O O O 4- C1 O m aZ r- c NO O O Lo Q a O i� ' _J 70 U • - U � -�--� m .� + I Adak LL Q •v� L� - 3 / 0 / 0 w� ;; Io2 j LL o :o L J iL - F.F. _ F.F. MIN. PROPOSED &UNITE 5 HOT-TUB i=R0F05EI7 EAST ELEVATION (REAR) SCALE: 1/4" = P-O" FROFCSF_r7 NORTH ELEVATION (LEFT SIDE) SCALE: 1/4" = P-O" z w ALLOWABLE H6T. PER PYRAMID LAW O to liJ / a 0 PROJECT: EXISTING ROOF M 0 LTZ UNDER CO #Z24332; 05/06/gb; RESIDENCE / 1600 ALVAHS LANE / CUTCHOGUE, NY 11935 DRAWING TITLE: ° PROPOSED EXTERIOR ELEVATIONS EILm PROPOSED POOL SECTION DESIGN DETAILS 45' PAGE: A-201m00 DATE: 4 09/25/24 5 OF 7 ILI] 104 .ri 1 71 m I GRADE PROPOSED ACCESS HATCH PROPOSED &UNITE 5 a, HOT-TUB FROPOSE �) SOUTH ELEVATION (R I O HT SIDE) i ROFOSEI� NEST ELEVATION (FRONT) SCALE: I/4" = I'-O" SCALE: I/4" = I'-O" STRUCTURAL PLAN NOTES OI FOUND d POSTS FOR ND. DECK: Q b"xb" P.T. P05T UPON 12"0 P. GONG. PIER 0 W FOR WOOD STAIRS ® GRADE 1 2 T ; W J C6 O2 4" THK. P. GONG. PAD 8" WIDE x REOV LENGTH UPON - —— _ — — — — — —. M 6" GRAVEL UNDER 2"A2" P.T. STAIR STRINGERS ® 4 Q +-1 CV MAX. IV' O.G.,U.O.N. (MIN. 5 STRINGERS) -4ANIGAL SYSTEMS: m -_' — — — — — — — — — — m •c Lo �TALL/REROUTE ALL EQUIPMENT AS PER MANU. SPEG.'s — — — — — 0 O3 %INTAIN 50"x5O" CLEARANCE IN FRONT OF MECHANICAL =t) DBL. F.J. Q RESERVE T5 AS PER NY5 MG 506.1 %INTAIN ALL APPLICABLE VENTING CLEARANCES 11 � — — — I } w QUIRED PER z NYS MG t04. I O TYPICAL LEDGER BOARD ® EXT. DECK: APPLICABLE,DISCONNECT,REROUTE, $ RECONNECT O CV 0 4 O I. (1) 2"x P.T. BD. TO MATCH DEPTH OF JOISTS UIPMENT TO EXIST. PIPING A5 REQ.'D. I w I I I a •— L() -sed- I= U1 PROPOSED O 2. SECURED w/(2) 5/8" 0 x 5" LONG H.D. CAL. LAG BOLT5 O HOT TUB 15" SPA 2 X U N ® I6" O.G. GAL MECHANICAL AREA NOTES: I x— 4a.o S.F. BENCH C 5. INSTALL H.D. 6ALV. JOIST HANGERS BY 'SIMPSON' (OR )R HP. FR. FLOOR - PROVIDE 1/2" GONG. BD. BY O Q O 0 O 4-J EQUAL) JROGK" (OR EQUAL) i� I 3 O NEW 2"x8° J'l 6SPA I ate--+ 0 m 4. PROVIDE FLASHING TUCKED UNDERNEATH 51DIN6 4 >R PC. FR. WALL5 - PROVIDE (1) LAYER OF 5/8 zW CVco BENT OVER TOP EDGE OF LEDGER 51D. PE "X" GYP. BD. UL U305 (OMIT ON GONG. WALLS) Imp P.T. D.J. 5 O O 5. SEE NOTED DETAIL BEN NEW, INSTALL FURNACE/BOILER AS PER MANU. I Q ® Ib O.G. I I A-401 Q '— �' 6 AND AS PER NY5 MECH. AND FUEL CAS GORE - iEN EXIST., MECH. EQUIP. SHALL BE VERIFIED THAT Q I TPL. F.J. — — — — CONFORMS TO NY5 MECH. AND FUEL 6A5 CODE ui PROV. HANGER5 )MB. AIR VOLUME AS PER MANU. 5PEC.'s - PROVIDE WOOD n :ESH AIR INTAKE FROM EXTERIOR DBL. F.J. DECK tjJ MNTAIN OR PROVIDE FURNACE/BOILER ELECTRICAL ? �j ? ? 4 V _ g 1ERCENCY SHUT OFF 5WITGH - ( p IL p >R 6A5 SERVICE, PROVIDE 6A5 SHUT OFF 5WITGH 11 Q � Q Q X� I TILE STRIP )GATE MECH. EQUIP. TO ALLOW FOR PROPER .EARANCE5 AS PER CODE tV ® N ® �• AT TOP;H.O. :OVIDE 3" FLOOR DRAIN IF REQ'D BY EQUIPMENT d EXIST. STAIRS w ? PROP. DECK 2' X 3' ° II ^` TO SELECT )NNECT TO SANITARY SYSTEM AS PER NY5 I p iI .UMBINC CODE W/NEW HIDDEN z Q ACCESS HATCH II 6UNITE 1 BILGO AGGESS t I FINISH SOT TUB �,•J ' a PLIANCE5 JOINED THROU6H A COMMON NATURAL I $ HATCH L // // // // // / a II ZAFT VENTING SYSTEM SHALL COMPLY WITH ALL 4 Q \\ \\ \\ \\ \\ \\ II °CTIONS OF 2020 NY5 RC 62421. _ _ _ _ _ _ //\//\//\//\//\// ^ I I SEE SECTION n , O PLANS FOR EXIST. UP DEPTHS 4 EXIST. \,U'NDISTURBED\ Q EARTH >GAS \/\r\ • M— METER \ \ \ (I) #4 BENT \/ / //I\11, . EBARO 161, O.G. U EXIST. EXIST. GAS WATER W/H d BOILER \\X� \ ' II°11 4 GONG. SLAB RELOCATED FILTER \ \ \ \ \ \ \ I1 j1 XN ER $ W.W.M. BETWEEN // // �/ // // // // / ^II II• • (2) # 4 REBAR CENTER d UPPER ; OF SLAB BOILER m //\\//\\//\\//\\//\\ \ \// CONTINUOUS SECURED IN PLACE DURING POUR — VENT UNEXGAVATED EXIST. /�\/�\/�\/�\\\\/\\\\\\\ •II.I� 2" RIGID n, AREA //�5) #4 REBAR\ / / / •L I INSULATION W T _ \ \ • ' I ° VAPOR BARRIER Q IS"xIB" DEEP P.\ r- \ II° ° 1� b" COMPACTED EXIST. GONG. GRADE/ a--.---Q-�7�___« GRAVEL BASE BASEMENT I I I I — BEAM (4,000 P51 - , lt5A SF. '\# 3 STIRRUPS �__ __--� • /� /\/\ \/ EXIST. 2X5 F.J. //(5) #4 REBAR •• °° . //�UNDISTURBE)7// ® Ib" O.C. V.I.F. I I \\�� �� �� �`�� % ° ^ a /�� /R� %\\\ (I) #4 A.REBAR FILE - \ \ \ \ \ //\\/ 1 � \�VER EA. PILE/,�.� /\ \\/ 2_2 EXIST. PANEL ELEG. / \// ELM EXIST. METER AGGESS OPENING HOT TUB/DF—C< DETAIL A�-401.00 SCALE: 3/4" = I'-O" FR01=OSMD FOUNDATION STRUCTURAL. PLAN SCALE: I/4" = P-0" z w O V z0) W oI� 0 � luo m < O Q MIN. 4" BETWEEN EDCE5 OF PROJECT: p m 1-1/2" SQUARE BALUSTER (STYLE TO SELECT) SIMPSOIN H2.5A RAFTER M 0 LTZ TIE (OR EQUAL) RESIDENCE 5/4"x6" P.Tr.DECK 5/4"xb" P.T. E50ARD5 DECK BOARDS P.T. DECK JOISTS AS NOTED ON PLANS 1600 ALVAHS LANE 5/4" x REQ'D I I CUTCHOGUE, NY 11935 HEIGHT P.T. RISER ° ° (2) I/2 0 HOT DIPPED 6ALV. EXTERIOR SHEATHING AS BOLTS ® EA. POST w/OVERSIZED PER SECTION NOTES I _ _ __ __ ___ _ _ _ P.T. D.J. AS = —WA5HER5 d END NUT PREBORED DECK BOARDS PER PLAN iv INTO BEAM, POST,DECK TIE d SIDING MATERIAL A5 DRAWING TITLE: \2"x BLOCKING ® EA. = RIM BOARD A55EMBELY PER SECTION NOTES STRINGER TO MATCH SIZE P.T. BEAM AS NOTED I BUILDING PAPER d HOUSE WRAP DESIGN DETAILS OF P.T. DECK JOISTS iv = SOLID BLOCK ® 12" O.G. EXIST. STUD WALL TO FULLY OVERLAP FLA5HIN6 STRUCTURE PLANS FASTEN STRINGER TO (2) SIMPSON DJT14Z (I) I/2"4) H.D. 6ALV. THRU BLOCKINGMIN. 6 DECK JOIST TIE ® BOLT w/ OVERSIZED WASHER Z FLASHING 5/4"xb" P.T. DEGKIN6 EA. POST d END NUT PREBORED INTO FASTENERS) P05T $ DECK JOI5T TIE (U.O.N. ON PLAN/ "SIMPSON" ABA44 CAP FOR 5ECTION/DETAILS) ) 2 xI2 P.T. STRINGERS ® I6 I ® COLUMN BASE DRAINAGE PAGE: 4" THK. x R WIDE x WIDTH � O.G. (MIN. 5 5TRIN6ERS ® (� 4"x4" P.T. P05T OF STAIR P. GONG. PAD ! EA. STAIRWAY) 11 GRADE - mAR —40loOO 12"� 'SONOTUBE' FILLED � II 2"xb" P.T. BLOCK IN BETWEEN NO E SOLID w/ P. p II EA. STRINGER. FASTENED TO GONG. oll ALL DEGKIN6 SHALL BE FASTENED (MIN. 4,000 P51U Z P. GONG. PAD w/ IcI164" x m w/COATED DEGKIN6 50REW5 BY ° „Z„ METAL DTT DECK TENSION 5-I/2" CONCRETE 5GREW5 BY 1' DECK MATE" (OR EQUAL) JOISTS AS PER PLAN FASTENED w/(2) FLASHING TIE BY 'SIMPSON' (OR _ "GALIBURN" (OR EQUAL) - MIN. ° p 5/8 � x 5 LONG HEAVY DUTY GAL. EQUAL) DATE: 09/25/24 6 OF 7 (3) 5GREW5 PER BLOCK O" MIN. LAO BOLTS ® 16" O.G. INTO MUD 51LL d RIM BD.;WHEN ® FOUND. WALL FASTEN COUNTER w/(2) 5/5"0 x 5" LONG APPROVED FLASHING P.T. DECK JOIST GRADE GRADE o n MASONRY ANCHORS ® 1611 O.G. AS PER PLAN EXIST. FOUNDATION WALL 2 EX7ER I Oil WOOD STAIR DETAIL � EXTERIOR WOOD DEGK DETA I L 4 LEDC ER GONNEGT I ON DETA I L �:••;��'� ; ,�� __ � : ` . A�-401.00 A�-401.00 5GALE: 5/4" = I'-O" -401.00 5GALE: 5/4" = I'-O" 5GALE: I" = I'-O" a Q 0 W uj Jco m w a N C V) o Z) rn r- O >: O C (v Z O a 'co Lr) 2x cv 0 O 0 4 � O m z N +J C d O Q W D -. -J 70 U - . _ U 4-J m U � EXIST. FRESH AIR PENT THROUGH ROOF �I IL IL I •rn V! I I I I I O I I O I a NOTE: I ALL PLUMBIN6.WORK I SHALL GONFOW TO I LOCAL PLUMBI" CODE i I I EOEND I FULL BATH I EXIST. BATH -------{ HOY KATER SUfFPLY NOTE: I ALL PLUMBING ab a p 1 ——I——— ——— r-————, ~ _ — COLD P ATER 00 FUEL 6A5 WORK REFL. 2 I SHALL CONFORM TO LOCAL PLUMBING CODE b 1 2 I FUEL 6A5 I iLAV. I 1 REFL. 1 21: I 1 REPL. PROVIDE "ABESGO FP200 FR I LAV. PROVIDE "ABESCCQ FP200 FR U 0 I I I I EXPANDING FOAM" (OR EQUAL) j �� EXPANDIN6 FOAMY(OR EQUAL) 0 v I I W G AT ALL PENETRATIONS IN FIRE Q REPL, w I z p� I I AT ALL PENETRATrI�NS IN FIRE �n Uwi 1 I NEW I RATED WALLS AND I 1 RATED WALLS ANID ISHOWI=R I FLOORS/GEILIN6S. PRODUCT �I I� �t �V W V FLOORS/GEILIN65i. PRODUCT I 14 1 CONFORMS TO ASTM E 614, N �I •v NEN * PIPING PENETRATIONS: I I �_ CONFORMS TO ASTM E 614, I. PROVIDE "ABESGO FP200 FR I I A5TM E 54, AND UL 1474 NI try SHOWER N 1 .n �J ASTM E 64,AND LjL.14'79 ATPANVINO ALL PENETRATIONS AT V4ALL5 _..1.._.._.._.._.._.._.I_.._.._..J AND FLOOR5/GEILIN65. MODIFIED MODIFIED BATH I 2.PRODUCT CONFORMS TO A5TM E KITCHEN I I 514, A57M E 64, AND UL 1474 ALL PLUMBIN6 WORK MODIFIED KITCHEN I MODIFIED BATH 2" MODIFIED SHALL CONFORM TO 1 KITCHEN �r ------------------- LOCAL PLUMBIN6 CODE I I 0 p 12 RELC�G.2"I „1 a 1 1IL LAY. 1 2 1 GLEAN OUT p RELOG. I RELOG. N RELOG. I I I AS REOV -A 1 I RELOG. IL 1 1 LAV. VENT EXIST. F.A.I. TO N~ 1 I I I �4 RELOC. Z u REMAIN a_ 1 j I I I I N.C. i ELOG. _ w u ANGE :: RELOC i- " I1 10 11 �O U I Q� m REGULATOR I-� DW i RELOG. I j� � �� I� c� G.O. OUT. n1 NI Iry EXIST. OAS PROPOSED G.O. -----1-----=-i- 1 ---- =--------- -----¢I LOG. HOT 1 r - .I.._.._.._.I._.._.._.._.1._.._. _.._. _.._ SHOT SUPPLY TUB SHOWER �.._..-..-..-. _. _L_.. OUT, G.O. qER EXIST. HOUSE t CONNECT TO TO OAS w MAIN DRAIN G.O. 506. DRYWELL � � EXI5T. WATER � t 1 MAIN SUPPLY SYSTEM I TO STREET 0 j 1 j rWATER MAIN Q Q TO SEPTIC j 1 L_.. _.. > PROJECT: SYSTEM � i1 U U N M 0 LTZ � X E W RESIDENCE x tu 1600 ALVAHS LANE CUTCHOGUE, NY 11935 FLUME31NC 17F;;�AIN / NASTE / VENT FLUM51NC R15ER - 5UFf=LY CA5 R15ER - SUFFL`I' DRAWING TITLE: SCALE: NTS SCALE: NTS SCALE: NTS PLUMBING RISER DIAGRAMS GAS RISER DIAGRAM PAGE: P-101moo DATE: 09/25/24 7 OF 7 a Sq 2$, - y AGRICULTURAL -_ _ 1O0 00 -'---- - ,_ - LAND __ SITE PLAN HATCH KEY: 4 PROP. NEIGHBORING PROPOSED BUILDING ADDITION y- ° WELL UNDER SGDHS d 1 PROPOSED ACCESSORY STRUCTURE 1. . a REF. NO. R-20 0006 i d L i r\ r I I Vq, L �' 0 G q I PROPOSED 2ND STORY '' W dE - I E PROPOSED MIN. 4'-0" J I HIGH FENCE AS PER NY5 I M �¢ POOL CODE 14 *- ....., .�.�.A .�.*�p- . ..,. �w.. ..ycn n' l , "*;', .e•+..- r •+ ..n.,A Q ;~ N �d p SITE LAYOUT NOTES: d . �/ O I. THIS IS AN ARCHITECT'S SITE PLAN 4 IS •� , r �ti. .., " ° SUBJECT TO VERIFICATION BY A LICENSED .' f� u? SURVEYOR. THE INFORMATION ;*." , Illy SURVEYOR. REPRESENTED ON THIS SITE PLAN I5 TO THE ��m ' `� Z ARCHITECT'S BEST OF KNOWLEDGE. ,�' ��•' y �� L; O cu 2. SURVEY INFORMATION WAS OBTAINED r- d FROM A SURVEY DATED MARCH 25, IQab ,y q• . `',_�`"' ,,`' ;s ^; d O X � N AND PREPARED BY: A, ,. ;<.4 ���. r ,' o 4-+ I I LO PEGONIG SURVEYORS, P.G. j,, Q 9 to _ a: O � N.Y. STATE LAND SURVEYOR h r¢>'. ;r"< `^� ,�,, •� , �� , � ,'.x: �,,< ; , ,` _ � r C 0 O r" LIG. #04ci618 ` • .�. ' � < ` EL.=17,02' �� P.O. BOX 01001 ° ��♦ p 1250 TRAVELER STREET SOUTHOLD NY IIci71 g b (631) 765-5020 00 ®' 1�' �' h''. ,( -.F•• w �' '.y' *4,•.*^."4;�w ,�" .,fir k ` , I t '`�.: a/. , <t a e, r „h. ' � \kr, :•�4"r' �' .`3 k, we+'"' xhN'�s." �^ pay 3 �, a ,'• VV � \ ` / ' t ;•�- ,r a_' ,,�,^' r-s'•.. i• a° •„ r 'd� Q }I. ,w '•.� '''y�., 0pj 0 I V v - - " t'�'«w. .r' .•v#iy`h �``: M .`ice* %e":e �� i l� _'' P'°"-,'^m .c" ,'., - v w IY � ,A,c.• 'e'v"Q�r a ,. .�.�+�''��c �` i. I, t :� �1 "" ,,,.,< 'u i� 4 ��i// �y R�Q I I :h � •. \•i,�'•..��''-'�.""�',,'"::tip, q �p l , dl _ ° z 1 ASRIGULTURAL ~ !, 0 p I I LAND a� Id IIl M EXIST. EXTERIOR H05E N ? BIB w/ WATER SUPPLY 1 . .. �".. T,t. .w• ,_ "" ¢.f.. ; .,... "', . 0 .. . � pQ i V !Y LINE CONNECTED N TO LOCATION MA THIS FIXTURE ONLY I VJ 1 - - - - - - - - - - - I . _ SCALE: NITS ¢¢�I� N W EXI5T. I-5TRY ND. I DE BUILDING L R0 Q DECKS (DRY BLDGJ e la I I I I FADE <E' I SEPTIC LEACHING - EXIST. WELL AS �b EXIST. I II i POOLS; SE SGHD I ,--- FIROP05ED TO BE f° J PLANS - FROFOSE1� INTERIOR KITCHEN RENOVATION, PROF. Nr1 ). REAR DECK W/ HOT TUB �-00 � .0 PROJECT LOCATIONE ABANDONED UNDER � ; SITE PLAN & ZONING DATA SG R-20-0006 �p I I dl TEST �-OO2 •Q GENERAL NOTES �If HOLE #2 D 1 ENERGY TABLE u i EL.=1a.32' q d_ _ _ -I - - - - - - - - - - ---- --------- - -- -------- --- -------T----- ----T---T -J PfROJEGT / ZONING DATA STRUCTURAL DESIGN CHARTS EXIST. 6 O HIGH Y - STOCKADE FENCE 1 i I z _ - d TAX MAP # -- - ---- 1000-102-04-8.1- - -- - W/WIRE MESH; FENr-,E I ¢¢ J - COMPLIES AS PER NY5 rld Q I i J ` - , ¢ ZONING DISTRICT AC NON-CONFORMING - ® � •0I PROPOSED DEMOLITION PLANS z POOLGODE � ! wI - - -',�- - - - - - - - - - - - - ��.; ' _ PROPOSED FOUNDATION PLAN PROPOSED 4 - - - - R - - _ ---- - ------ - g N DWELLING w/ f � I R - _ - I ¢ LOT AREA 1 1.0 ACRES z PROPOSED a w _ _ _iAD- - - -- a 0 PRIVATE WELL I, - - - - f) r !X - - - - - - - - - - _ _ F� , , I Gofo - MAIN DWELLING 8 05/O6/a6 #Z24332 -- -- W Q DETACHED GARAGE o �_ -- - ---- - -- A- O2 .0I PROPOSED FLOOR PLANS c� - - _ r�- - - - - - - - _ _ GofO -COVERED PORCH � 12/30/15; #38008 o w PROP. RELOCATION OF Ii z ,WATER SUPPLY LIME TO IQ _ _ - - - it X - - - - - - - - _ _ _ - � � Gofo - SHED -- -- - 02/OI/05; #Z30736 I � s tu REAR YARD HoS� BIB PRIOR VARIANCE APPROVAL 02/07/08; #6120 o 0 A-20I .01 PROPOSED EXTERIOR ELEVATIONS o w PROP. RELOCATION OF EXIST. d - - - ' - - _ _ � ,. U) a 8x12 I-STORY WD, FR.. SHED - _ ��'pI SUFFOLK COUNTY HD APPROVAL R-24-1083; 4 BEDROOM N a (<22' HEIGHT) (DRY 1BLDG) - _ _ __ L _ - - -i- - - - - - - - -PROP ` \ \ ` �1 FLOOR AREAS PER SOUTHOLD TOWN GORE, SECTION 280-207 (A)(I)(b) 00 ¢ 1 1 --- -- ---- -- -- -- --- - 11� I -- --- _ - POOL EXISTING 1 EXISTING -- - - - - - w O -D.W,- _ �I HABITABLE GROss A-40 ( •O DESIGN DETAILS 2 SPACE--=1 AREA o _ d PROPOSED STRUCTURAL PLANS c, z FIRST FLOOR AREA l 1,205 S.F. 1,205 S.F. -- - - - 1 -SECOND FLOOR AREA - F1,05q S.F. -- 1,05a S.F. - - -LO I _ EXIST. DRIVEWAY I �- Q •Q� PLUMBING RISER DIAGRAMSc1j & PATIO TO BE- , e�„' i �n o k 1 \ q =-- � AREA TOTALS---'- 2,262 S.F.sF --- 2,262 S.F.sF GAS RISER DIAGRAM o o o PROP. 4'x5' POOL EQUIP. PLACED I J vl� �� IQ i 15.0 wl EL.=30a46', , -¢-o-- MIN. IS' FROM SIDE YARD / � Lc�T GovERAO� PROJECT: PROVIDE BUiRIED i j 18.0 'j/ --- -r -=- -__ = T=-•- ,_- - _ _ -= - - -- -' _-= _•_ - -- - PROPERTY LINE; � I Lull � ELECTRIC WIRES FROM EXISTING I� �p j pl EXIST. RETAINING WALLS DWELLING (UNDER SEPARATE FILING) Ir I I i�0 / / w1 �� 5GUTHOLD TOWN CODE (SECTION 2&0-124) � z wI MOLTZ EXIST. SHE TO I mi \ \ ' PROPOSED MIN. 4'-0" DESCRIPTION (FOOTPRINT) AREA LOT- I i0� zr0" aI EXIST. - - _ ,� COVERAGE TBE RELOCATI•ED I /�z ��q p I PATIO T ' - F�., HIGH FENCE AS PER NY5Lu _ __ ____ L rm I I,- REMAIN-' - _ 1 POOL CODE TrOTAL LOT AREA 42,g76 S.F. RESIDENCE FROP. POOL DECK(UNDER SEPARATE I' I ✓lL I WD. FR. EL.-322 �.;3 EXI5TING DWELLING -- - ---- ----- I'= - - �0 - / 7j X ST. 1-5TRY. F 1,113 S.F. 2.690 FILIII I- i I I GARAGE w/ 1 z-- -- - ------ --- ------- -_- _ I 17a1' !_10.3' 511 F�.;�2 EXISTING COVERED PORCH led S.F. 0.490 1600 ALVAHS LANE EXIST. WELL AS PROPOSED PROP. '7'x-ri' HOT !� _ _;� �� (DRY BLDGa) EL.=52'4a -� ---- -------- - CUTCH®CUE NY 11935 TO BE ABANDONED UNDEF:-�O _ -�- - I LAB EL.=3 I EXISTING STEPS FROM DWELLING TUB WITHIN PROP. - }� 34 S.F. 0.1 SGDHS REF. NO. R-20-000b RAISED [DECK I ---'m•� 310 _ ('TOWARDS DRIVEWAY)_ - - - N ASPHALT DRIVE TO GARAGE _CGATION� E`.X15TINO ACCESSORY GARAGE 552 S.F. 0.890 DRAWING TITLE: PROP.. HOUSE DECK DDITION / I \. 0 �- BE MODIFIED I - - - --- -- A p r i y A5 5HOWN E:XI5TINO TRELLIS 156 S.F. 0.496 RELOCATED OUTDOOR SHOWER UPON Id I �I\ m I VACANT EXISTING SHED PROJECT LOCATION &SCOPE DECK DRAINING TO 54 DRYWELL w/ ___ ___�- LOT ('TO BE RELOCATED) _ - 101 S.F. 0.29 SITE PLAN & ZONING DATA 1 I �!.�15.7, r � 1 III, TRAFFIC-BEARING COVER 8 TOP -- -- --- - -_- ----__ - - --"�\- lOOO, I EXISTING SHED I I EXIST. 4' PER FENCE AS ('TO REMAIN) "102 S.F. I.6Jo __ -- PER NYS POOL CODE E:XISTING NM. FR. BLDG. w/ DECKS 1q5 S.F. 0.5% EXIST. 2-5TRY. I PROPOSED RAISED DECK W/ HOT l PAGE: ff f=R 255 S.F. 0.710 1 1 ND. FR. i d I I DWELLING w/ I Immillik PROPOSED INGROUND POOL 648 S.F. 1.590 U-00 BASEMENT \ CRAWL5PAGE �� ---- -- --- - EXIST. BURIIED (4 BEDROOMS) "� 1 TOOTAL AREA OF ALL STRUCTURES 3,765 5TF 8.890 GAS LIINE �� w� I F.F. EL.=37.25' MAXIMUM LOT GOVEF:AGE ALLOWED: 2090 !Y UD 58.a I _ - - ----- -- DATE: 01/20/25 1 OF 7 w i Ex1sT. COVERED Q ZO>NINC REGULATIONS MAIN BUILDING uj 0 I W 1 SD>UTHOLD JTOWN GODS (`280 - 124 ) ----s-=•-__._v,. _.___,: -_- t_. ..__z - _ � ry l Qi p C Q 1 EXIST. PROPOSED COMPLIES 50UTHOLD TOWN CODE 280-207 0�� �a�'= (Y EXIST. TEST - - �_ _ -- -- - - - --- - -1 _ I HOLE #I I ENO LOT SIZE / AREA IN -- - - z 0t WELL EXIST. -__- -- - - ALLOWABLE TOTAL-' ^� ' N 5LATE 0 h141N. FRONT YARD ! 50.0' 2Q.7 2�i.7 �' EXCESS OF 40,000 42�76.0 S.F. 2,�f76.0 S.F. GFA GFA ! `4 �s N WALK IcV Z --- --- -------j-- (EXIST.) -=_-� -_ j - --_-! -_ �_ ----_ ��I X u� NO W LOTS CONTAINING 7,100 S.F. w iv h�11N. SIDE YARD 20.0 �UP TO e,0,000 S.F. I II.O II.O (EXIST.) , MAX. - -- - ----- I' tA� 037 � O�� X EXIST. UTILITY POOLE N4 - •• _ _ I N �l hr 1N. COMBINED _-- -- _- ------- ----- - - r - ----- ---- ALLOWABLE S.F. � � 7' 08 t 2A02 / SIDE YARDS _ 40.0 bQ.�i bq.a YES _ _ �`-' -__-- --- -- J= PLUS 5% OF EXCESS 5,ID0.0 S.F. 148.8 S.F. 5 248.8 S.F. 2,341 S.F. ' F to I p LOT AREA OVER i - - - - _ _ -- _ _ p G G I WIN. REAR YARD 60.0 346a2 j 331.q YES 40,000 ITE H t CJ" EXIST. UTILITY POLE h AXIMUM HEIGHT 35.0 22.8 22.8 YES L SCALE: 1" = 15'-0" �`* PROPOSED WORK DOES NOT INCREASE EXISTING NON-CONFORMING SETBACK J __ . PLUMBING ____ __--_"_-- CARPENTRY WOOD FRAMING MATERIAL STANDARDS I. CONTRACTOR SHALL INSTALL WATER SUPPLY, DRAIN, WASTE, AND VENT (DWV) $� \ / /� G NOTES 4 SPEC;1 F I C.A71 ONS I. ALL LUMBER SHALL BE DOU6LA5 FIR LARCH #2 4 BETTER (Fb = 8'75) UNLE55 THE PROVISIONS OF THI5 STANDARD ARE NOT INTENDED TO PREVENT THE USE SYSTEMS TO NY5 PLUMBING COME AND NY5 DEC REGULATIONS. E -- ABBRE X I A7 I ON J OTHERWISE NOTED. OF ANY MATERIAL OR METHOD OF CONSTRUCTION NOT SPECIFICALLY __________� IT IS THE CONTRACTOR'S RESPONSIBILITY TO KEEP THIS CONSTRUCTION'DOCUMENT BINDER PRESCRIBED HEREIN. WHEN IT CAN BE SHOWN, AND THE AUTHORITY HAYING � TOSETHER AT ALL TIMES. IT IS ALSO THE CONTRACTOR'S RESPONSIBILITY TO READ ALL NOTES, 2. PROVIDE HOT AND GOLD SHUT OFF VALVES AT ALL FIXTURES. BD. BOARD INSUL. [INSULATION SPECIFICATIONS,AND BE FAMILIARIZED WITH THE PLANS PRIOR:TO WORK 2. ALL LUMBER IN CRAWL SPACES TO BE IS ABOVE SCRATCH GOAT. MAINTAIN JURISDICTION FINDS BY EXPERIENCE, MODELING, OR TESTING BY AN APPROVED ________"-"-_ _ __ _____ _ _ -__-__ __ ____-._ -�� AND AT BASE OF VERTICAL Y�IASTE PIPES. _ _ a ----- ------ ------ -------- UCT OR PROCEDURE ES OR 8" MIN. FOUNDATION EXPOSURE. GREATER HAT A STRUCTURAL SAFETYOR DURABILITY, SUCH PRODUCT NT PROCEDURE 3. ALL HATER PIPING TO NAME GLEAN OUTS AT ALL CHANCES IN DIRECTION BFE �I BASE FLOOD ELEVATION INT. INTERIOR Q 3. SILLS TO BE P.T. AND SECURELY FLASHED WITH A TERMITE SHIELD, ALSO SHALL BE DEEMED TO CONFORM TO THE REQUIREMENT5 OF THIS DOCUMENT GENERAL PROVIDE SILL SEAL/INSULATION. SIZE OF SILL TO BE (2) 2"x6", UNLESS (I) 2"xb° (THIS DOCUMENT I5 TO MEAN A REFERENCE TO THE CURRENT AMERIGAN WOOD 4, USE 4" CAST IRON THROUGiH FOUNDATION WALL AND PITCHED AT I/8" PER CBLDG_ JCBUILDING �� �I KIPS (1000 LBS) I. NO WORK TO START UNTIL APPROVED PLANS ARE OBTAIN'dED FROM THE O MATCH FLOOR HEIGHTS WITH THE EXISTING STRUCTURE. GOUNGIL'S WOOD FRAME CONSTRUCTION MANUAL AND THIS PS FORMAT, AS FOOT. LJJ APPLICABLE BUILDING DEPARTMENT. IS NECESSARY T M T L BM BEAM MANU. SPEC.'S MANUFACTURER'S 5PEGIFICATIONS APPLICABLE AS A DERIVED WORK). - - - -- --- _------- --- -____ �_ -- __ -' J cu 4. AT FLUSH FRAMING USE I6 GAGE METAL JOISTS HANGERS $Y "TEGO" OR 5. GENERAL TRAP AND WASTE SIZES AS FOLLOWS, UNLE55 OTHERWISE NOTED: B.O. BOTTOM OF MAX_ �'MAXIMUM M 2. ALL CONSTRUCTION SHALL BE PERFORMED IN A WORKMAIN LIKE MANNER. I. IDENTIFICATION: ALL SOLID-SAWN LUMBER, CLUED LAMINATED TIMBER, - DISH WASHER..........................................2" _ ALL DIMENSIONS, CONDITIONS, AND APPLICABLE INFORMATkON OF EXISTING EQUAL. - ----- - - -- STRUCTURE/SITE SHALL BE FIELD VERIFIED BY GENERAL CONTRACTOR. PREFABRICATED WOOD I-JOISTS, STRUCTURAL COMPOSITE LUMBER, - KITCHEN SINK........................................... BOT. BOTTOM i�MEGH. MEGHANIGAL .c 0 5. MINIMUM, DOUBLE HEADERS AND TRIMMERS AROUND ALL OPENINGS IN PREFABRICATED WOOD TRUSSES, CYP5UM, HARDBOARD, AND STRUCTURAL - LAVATORY................................................2" --- --- FLOORS ROOFS, AND WALLS. PANELS, SHALL CONFORM TO THE APPLICABLE STANDARDS OR GRADING - �- sHowER/TUB...........................................2° B.O.W. BOTTOM OF WALL J MIN. 1 MINIMUM J 0 3. ALL WORK SHALL CONFORM TO NATIONAL, STATE, AND LOCAL CODES RULES SPECIFIED IN 1.1 THROUGH 1.8. - TOILET.........................................................3" - ---- -_ --- ---__._ _ __ _ -0 � Q AND AUTHORITIES HAVING JURISDICTION. G.J. CEILING JOIST NAVD88 NORTH AMERIGAN VERTICAL DATUM O'F Ig88 - (9 U.O.N. I.I. LUMBER: ALL WOOD MEMBERS USED FOR LOAD-BEARING PURPOSES, - FLOOR DRAIN...........................................5" -- -- --_ 1 ___ ______ _ _ i i z 4. ALL UNNOTED OR NON-VISIBLE EASEMENTS ARE THE RESPONSIBILITY INCLUDING END-JOINTED AND EDGE-GLUED LUMBER, SHALL BE IDENTIFIED -- `- -- -- - I 0 C N O OF THE OWNER/BUILDER 7. ALL BEAMS, GIRDERS, ETC. TO HAVE MIN. OF 3-1/2" BEARING BY THE 6RADEMARK OF A LUMBER 6RADIN6 OR INSPECTION A&ENGY „ COL. COLUMN l NYC BG NEW YORK CITY BUILDING CODE 6. ALL SYSTEMS TO HAVE ONIE 3 MAIN VENT STACK AND INCREASED TO 4 _ �- --_--- WHICH PARTICIPATES IN AN ACCREDITATION PROGRAM, SUCH AS THE d Y 5. ANY OM15510N5 OR DI5GREPANGIE5 OF PLANS AND/OR JJO$ CONDITIONS THROUGH ROOF. _ I - -- - .- SHALL BE CLARIFIED WITH THE ARCH ITE:GT/ENGINEER BEFOiRE PROGEEDIN6 8. MIN. HEADER TO BE (2) 2"xl0" UNLESS OTHERWISE NOTED. AMERIGAN LUMBER STANDARDS COMMITTEE OR EQUIVALENT. THE CONT. CONTINUOUS O.G. ON CENTER U '- GRADEMARK SHALL INCLUDE AN EASILY DISTINGUISHABLE MARK OR '7. PROVIDE FROST-PROOF HOSE 5I55 WITH EA51LY ACCESSIBLE DRAIN 4 -- - - - - L-_ -- - - 00 O XC 4- N WITH THE WORK. q. ALL WOOD SILLS AND WOOD IN CONTACT WITH MASONRY/CONCRETE TO BE INSIGNIA OF THE GRADING AGENCY WHICH COMPLIES WITH THE DRAIN GOOKS A5 REQ'D. H05�E 5I55 SHALL BE PROVIDED WITH BAGKFLOW DBL. DOUBLE OGG. OCCUPANCY _c O m •; CO REQUIREMENTS OF U.S. DEPARTMENT OF COMMERCE P520-qq. - - ------- P T PROTECTION. - --- +J �'' Ln 6. NO DEVIATIONS OR CHANCES TO THE STRUCTURAL 5Y5TE`_M SHALL BE MADE DFE DESIGN FLOOD ELEVATION O.H. I,OVERHANG ON p c>3 .. UNLE55 APPROVED BY THE ARCHITECT/ENGINEER. -- - F-" - _ --_'-` -- ---"' -- - __ _ 1.2. GLUED LAMINATED TIMBERS: GLUED LAMINATED TIMBERS SHALL MEET _ - _ ---- -- Q r-- 10. ALL EXTERIOR SHEATHING SHALL BE NAILED AS PER FASTENING SCHEDULE 8. WASTE FROM CLOTHES WASHERS AND LAUNDRY TUBS ARE TO BE PROVIDED - - - - - - ON PAGE 6-003. GENERALLY, SHEATHING IS OF 1/2" THICKNESS ON WALLS AND THE PROVISIONS OF ANSI/ALTO A I q0.1 STRUCTURAL GLUED LAMINATED WITH BACK FLOW PROTECTION. DIM. DIMENSION �]_____PBFE PRELIMINARY BASE FLOOD ELEVATION '7. CONTRACTOR TO VERIFY DIMEN51ON.5 OF FOUNDATION WITH FLOOR PLANS ROOF AND 15 OF GDX CRAVE, UNLE55 OTHERWISE NOTED. SEE FLOOR PLANS TIMBERS. - - ------ �I --- --- BEFORE THE START OF FRAMING D.J. �DEGK JOISTS- P. GONG. I POURED CONCRETE �: FOR ADDITIONAL NAILING OR DIFFERENT NAILING REQUIREMENTS WHEN 41. THE WATER SUPPLY AND SIANITARY SYSTEM SHALL COMPLY WITH LOCAL ___" ---- - __ _ ________ APPLICABLE. 1.5. PREFABRICATED WOOD I-JOISTS: ASSEMBLIES USING PREFABRICATED HEALTH DEPARTMENT STANDA�.RDS AND REGULATIONS. 8. DRY WELLS AS REQUIRED BY STATE AND LOCAL CODES- WOOD I-JOISTS SHALL MEET THE PROVISIONS OF A5TM D5055 EA. �AGH - _ - PL. j PLATE STANDARD SPECIFICATION FOR ESTABLISHING AND MONITORING - --= ---"""__= __ __ - 71 II. SUB FLOORING, GENERALLY, TO BE OF 3/4" THIGKNE55 AND OF GDX GRADE. 10. APPROVAL AND INSPECTION IS REQUIRED BY LOCAL JURISDICTION PRIOR q. DO NOT SCALE DRAWINGS, WRITTEN DIMENSIONS TAKE PRECEDENCE STRUCTURAL CAPACITIES OF PREFABRICATED WOOD I-JOISTS, THI5 ELEV. ELEVATION PLYWD. ;PLYWOOD NAILING AS PER FA5TENIN6 SCHEDULE ON PACE 6-003 AND CLUED, U.O.N. TO CONGEALMENT OF PLUMBINN6. -- ___ _- DOCUMENT, THE GOVERNING BUILDING CODE AND ANY ADDITIONAL -- - ---" -- - --- - ! 10. OWNER/BUILDER ARE RESPONSIBLE FOR ALL IN5PEGTIONr15, APPROVALS, REQUIREMENTS AS SET FORTH IN THE MANUFAGTURER'5 CODE EQUIP. _] EQUIPMENT - - - - F.T. �!PRESSURE TREATED CERTIFICATES, CERT. OF OCCUPANCY GR COMPLETION AND U.L. APPROVAL 12. EXTERIOR SHEATHING TO BE COVERED WITH TYVEK HOUSE WRAP OR II. NOTCHING AND BORING OF STUDS, JOISTS, RAFTERS AS PER BUILDING GORE. _ APPROVED EQUAL. EVALUATION REPORT. NO NOTCHING ANV BORING O1F STRUCTURAL MEMBERS SHALL BE PERMITTED - --- - NOR ANY POTENTIAL DAMAGE: THEREOF. EXIST. �X15TING �I REQ D _I REQUIRED 11. THESE SET OF DRAdNIN65 ARE THE PROPERTY OF ANTHONY PORTILLO, RA 1.4. STRUCTURAL COMPOSITE LUMBER: 51NSLE MEMBERS OR ASSEMBLIES -----� �� AND SHALL NOT BE ALTERED OR BE REPROVUGED WITHOUT' WRITTEN 15. BLOCK EXTERIOR STUD WALLS AT HALF STORY HEIGHTS AND AT USING STRUCTURAL COMPOSITE LUMBER SHALL MEET THE PROVISIONS OF - -- I EXTERIOR Rl �'RISER UNSUPPORTED EDGE SEAMS OF EXTERIOR SHEATHING. 12. PER NY5 PG 425.4, A 4 x31 CLOSET BEND SHALL $E AN ACCEPTABLE - ___"_---__ _- _____ _ ___ PERMISSION FROM THE ARCHITECT. A5TM D5456 STANDARD SPECIFICATION FOR EVALUATION OF WATER CLOSET CONNECTION. WHERE A 3" BEND 15 UTILIZED, A 4"x3" FLANGE - --" U STRUCTURAL COMPOSITE LUMBER PRODUCTS, THIS DOCUMEN, THEF.A.I. FRESH AIR INTAKE � RM. ROOM � - _ _ _ _ RESPONSIBLE FOR DESIGN INTENT ONLY. EXCEED 8-O AND AT EVERY 8-O . SET FORTH IN THE MANUFAGTUi¢ER'S CODE EVALUATION REPORT. FOUNDATION, CONCRETE, AND IMA50NRY FAR D 12. THE ARCHITECT 15 NOT RETAINED FOR 5UPERV15ION OF 7rHE WORK AND 15 E PROVIDE " AND AT BRAYING AT JOISTS, STUDS, AND RAFTERS WHEN SPANS GOVERNING BUILDING CODE, AND ANY ADDITIONAL REQUIREMENTS AS INSTALLED TO G: THORN. FLOOR AREA RATIO 1 R.R. _i ROOF RAFTER - _� I. CONTRACTORS TO VERIFY ALL DIMENSIONS OF EXISTING FOUNDATION A5 IT _ m 15. THE CONTRACTOR SHALL OBTAIN CERTIFICATE OF OGGUiPANCY• 1.5. PREFABRICATED WOOD TRUSSES: ASSEMBLIES U51N6 PREFABRICATED APPLIES T ATHE NE IN SUCH 1EIN6 PERFTORMED ANDT SHALL HAT THE COORDINATE NDITIONS H F.A.V. FRESH AIR PENT � TL. �I STEEL � �� W 15. TOP PLATES TO BE DOUBLED AND LAPPED AT CORNERS, SEE ALSO PAGE RE 6-004. WOOD TRU55ES SHALL MEET THE PROVISIONS OF THIS DOCUMENT, THE 14. THE CONTRACTOR SHALL KEEP PREMISES REASONABLY GLEAN AT ALL 60VERNIN6 BUILDING CODE, AND ANY ADDITIONAL REQUIREMENTS AS THE FIRST AND SECOND FLOONR5 ARE TAKEN INTO ACCOUNT. FF FINISHED FLOOR S.V. SMART VENT i TIMES. AT THE COMPLETION OF WORK, THE CONTRACTOR SHAALL REMOVE ALL I6. APPLY ALL CONDITIONS ADDRESSED IN FASTENING SCHEDULE AS SET FORTH IN ANSI/TPI I NATIONAL DESIGN STANDARD FOR METAL PLATE -- ---- --- -- ------- __ �- RUBBISH, WASTE MATERIALS, TOOLS, ETC., GLEAN CLASS AN41D LEAVE WORK NECESSARY. CONNECTED WOOD TRU55 CONSTRUCTION, THE TRU55 PE51ON DRAWIN55, 2• ALL FOOTINGS TO BEAR OM FIRM,VIRGIN, UNDISTURBED 501L FF ELEV. FIRST FLOOR ELEVATION -1 ____1 TO BE DETERMINED _ � BROOM GLEAN. OR THE MANUFACTURER'S CODE EVALUATION REFORT. J. r I"I. PROVIDE ALL NAILING AND STRAPPING ADDRESSED ON PAGES C-003. 3. SOIL TO HAVE MIN. BEARING CAPACITY OF (1) TON/5Q. FT., U.O.N. F,- ;FLOOR JOISTS TEMP GL. TEMPERED GLASS `.,J 15. THE CONTRACTOR SHALL CARRY WORKMAN'5 COMPENSATION AND GENERAL I8. AT "WET WALL" PARALLEL TO JOISTS FRAME DOUBLE J015T AS PER CODE. 1.6. GYPSUM: GYPSUM MATERIAL USED IN A STRUCTURAL APPLICATION SHALL LIABILITY INSURANCE. ALL SHALL COMPLY WITH STATE AND LOCAL CODES MEET THE PROVISIONS OF ASTM G36 SPEGIFIGATIDN FOR GYPSUM 4. FOOTIN05 TO REST A MIN. OF 4-O BELOW GRADE, UNLE55 AND ORDINANCES. GENERALLY, SEPARATE DOUBLE JOIST THE THICKNESS OF WALL ABOVE. SUB FOUND. FOUNDATION THK. THICK l FLOOR SHALL NEVER EXCEED A I6 SPAN. WALLBOARD, ASTM 05-7 SPECIFICATION FOR GYPSUM LATH, OR A5TM c7ci OTHERWISE NOTED ------ "" _ J --- 16. THE CONTRACTOR SHOULD FULLY GUARANTEE HIS WORK AND THE WORK OF SPECIFICATION FOR GYPSUM SHEATHING BOARD. 5. WALL5 TO BE POURED CONCRETE OF SIZE SHOWN ON DRAWINGS, U.O.N. FRGE - -- - �L.00D RESISTANT CONSTRUCTION ELEVATION T.O.W. TOP OF WALL �0- lel.THE SUB-CONTRACTORS FOR A PERIOD OF AT LEAST ONE 1YEAR AFTER AT ROUGH OPENINC75 PROVIDE ALL APPLICABLE NAILING AND STRAFFIN6 � -- ---- ----- ---- COMPLETION OF PROJECT. AS PER PAGE 6-003. 1.7. HARDBOARD: HARDBOARD USED IN A STRUCTURAL APPLICATION SHALL r R. FRAME - -� Tr__ _ _ �I TREAD n1 MEET THE PROVISIONS OF ANSI/AHA A135.4 BA510 HARDBOARD OF 6. NO BACK FILL SHALL $E PLACED AGAINST FOUNDATION WALLS _ W 1-1. THE CONTRACTOR SHALL INDEMNIFY AND HOLD HARMLE55 THE OWNER, 20. P.T. SPECIFIES PRESSURE FRE5ERVATIVELY TREATED LUMBER IN ANSI/AHA AL35.6 HARDBOARD SIDING. UNTIL I TIER OF FRAMING IS IN PLACE. TYPICAL FRPR.-- -__-- FIREPROOF TYP. _ __-__- _- --__-- " _-_ __ - -- ARGHITEGT/ENOINEER, AND THEIR AGENTS AND EMPLOYEES FROM AND ACCORDANCE w/ AWPA 022;WHERE DRILLING AND/OR GUTTING OCCURS, FIELD --- - 1.8 STRUCTURAL PANELS: '7. FOOTINGS TO BE POURED O,ONGRETE OF SIZE SHOWN ON DRAWINGS. [I, AGAINST ALL CLAIMS, DAMAGES, LOSSI=S AND EXPENSES, IINGLUDING TREAT LUMBER w/COPPER NAPTHENATE WHICH SHALL CONTAIN 2% COPPER FTC. FOOTIN U.O.N. �I UNLE55 OTHERWISE NOTED ATTORNEYS FEES ARISING OUT OF OR RESULTING FROM THE PERFORMANCE OF METAL BY REPEATED BRUSHING, DIPPING, OR SOAKING UNTIL THE WOOD -"-- AR ------ --_- - li --- ABSORBS NO MORE. ALSO, FOR HARDWARE USED WITH P.T. LUMBER, Le).1. PLYWOOD: PLYWOOD USED IN STRUCTURAL APPLICATIONS 5HALL 6. ALL OPENINGS FOR BEAM POCKETS, UTILITIES, ETC. TO BE FILLED GYP. BD. GYPSUM BOARD VERT. �I�YERTIGAL A� THE WORK PROVIDED THAT ANY SUCH CLAIM, DAMAGE, L05�5 OR EXPENSE (A) SOLID WITH CONCRETE. CONTRACTOR 15 TO INSTALL HARDWARE THAT I5 SPECIFIED BY P.T. LUMBER MEET THE PROVISIONS OF U.S. DEPARTMENT OF COMMERCE _-__ ___ --_--_--- -_ _- IS ATTRIBUTABLE TO BODILY INJURY, SI .KNESS, DISEASE 01�2 DEATH OR TO MANUFACTURER SUCH A5: HANGERS, NAILS, 5CREW5,FLASHING, ANCHOR BOLTS, VOLUNTARY PRODUCT STANDARD I (PS 1) CONSTRUCTION AND H.D. HOLD DOWN lV.I.F. VERIFY IN FIELD INJURY TO OR DESTRUCTION OF TANGIBLE PROPERTY (OTHER THAN THE WORK INDUSTRIAL PLYWOOD, U.S. DEPARTMENT OF COMMERCE VOLUNTARY q• ANCHOR BOLTS SHALL BE IIN ACCORDANCE WITH PACE 6-003. l ITSELF INCLUDING THE L055 OR USE RES51JLTING THEREFROMU. (B) 15 CAUSED IN ETC. FOR LOCATIONS SUCH AS: LEDGER BD., SILL PLATE, DECK CONSTRUCTION, --___ J -----=--- _ _ -_-- _ --_--- -- ---- - ____=-_ ETC. ANY REFERENCES TO GGA ARE TO REPLACED WITH P.T. PRODUCT STANDARD 2 (P52) PERFORMANCE STANDARD FOR HDR �i"HEADER_ w/ � WITH WHOLE OR IN PART BY ANY NEGLIGENT ACT OR OMISSION OF THE WOOD-BASED STRUCTURAL- USE PANELS, APPLICABLE CODE 10. ALL CONCRETE TO HAVE AkN ULTIMATE COMPRESSIVE 5TREN6TH AT 28 - - - - - - -- ---- - CONTRACTOR, ANY SUBCONTRACTOR, ANYONE DIRECTLY OK INDIRECTLY 21. LVL (LAMINATED VENEER LUMBER) DENOTES EITHER OF THE FOLLOWING: EVALUATION REPORTS. DAYS OF 4,000 P.5.1., U.O.N. IHNGR I HANGER D. �!WOOD _� EMPLOYED BY ANY OF THEM, OR ANYONE FOR WHOSE AC7S5- ANY OF THEM MAY __ _ ____ A. WEYERHAEUSER TRUS JOIST 2.OE MIGROLLAM LVL BE LIABLE REGARDLE55 OF WHETHER OR NOT IT 15 GAUSEID IN PART BY A II. GONG. SLABS TO REST ON MIN. OF 6" FINE GRAVEL OR SAND WITH -- --- -- - - i PARTY INDEMNIFIED HEREUNDER. B. CEORGIA PACIFIC 2.OE 6-P LAM LVL 1.5.2. ORIENTED-STRAND BOARD (055), WAFERBOARD ORIENTED-STRAND 6 MIL. POLYETHYLENE VAPOR BARRIER UNDER HOR. �FHORIZONTAL �� �I ZONING RESOLUTION PSL (PARALLEL STRAND LUMBER) DENOTES: BOARD OR WAFERBOARV USED IN STRUCTURAL IONS SHALL MEET A. WEYERHAEUSER TRU5 JOIST 2.2E PARALLAM PSL THE PROVISIONS OF U.S. DEPARTMENT OF COMMERCE VOLUNTARY _____-__- - --- ALL ______ I8. ALL MATERIALS, ASSEMBLIES, AND METHOD OF GON5TRLIGTION INCLUDING 12. COPPER FLASH ALL JOINTS WHERE SLAB ABUTS FRAMING. --__ -- __ BUT NOT LIMITED TO FORM-WORK, BLOCK-WORK, FRAMING, INAILIN6, PLACING ALL TO BE INSTALLED AS PER MANU. SPEC.s PRODUCT STANDARD 2 (P52) PERFORMANCE VOLUNTARY PRODUCT G I //�� ¢¢ I G /� I /� TG OF CONCRETE, ETC. ARE TO BE CAREFULLY SUPERVISED BY THE CONTRACTOR 13. BRICK VENEER TO BE ANCHORED WITH CORROSION RESISTANT TIES - - - I NSULI DTI ON �F - ENESTfi' T I ON RC�U I RMN I STANDARD FOR WOOD-BASED STRUCTURAL- USE PANELS OR TO BE SURE THEY ARE IN ACCORDANCE: WITH THE DRAWINOe, SPECIFICATIONS, 22• I-JOIST FLOOR SYSTEMS SHALL BE IN ACCORDANCE WITH THE WOOD APPLICABLE CODE EVALUATION REPORTS. (U WALL TIE PER (3) SQ. FT. -- _ APPLICABLE GORES AND 600D PRACTICE. DEVIATIONS FROM THE DRAWINGS FRAMING MATERIAL STANDARDS SECTION, THE GOVERNING BUILDING GORE, I AND SPECIFICATIONS WILL NOT $E PERMITTED WITHOUT WRITTEN AND ANY ADDITIONAL REQUIREMENTS SET FORTH IN THE MANUFACTURER'S I.8.3. PARTICLE BOARD: PARTICLE BOARD USED IN STRUCTURAL 14. FLASH JOINT AT BRICK LEDGE AND PROVIDE WEEP HOLES, i I GORE EVALUATION REPORT. APPLICATIONS SHALL CONFORM TO ANSI A208.1 AND ANY COMPONENT PROPOSED DESIGN VALUE CODE PRESCRIPTIVE VALUE $ CITATION (PER 202C NY5EGGG) COMPLIES 1' AUTHORIZATION OF THE ARGHITEGT/ENGINEER. MAX 32-O O G, TO DIRECT ANY CONDENSATION TO THE EXTERIOR. REQUIREMENTS AS SET FORTH IN THE MANUFACTURERS COVE H E RESPONSIBLE FOR ANY SHOP DRAWINGS 23. NOTCHES IN THE TOP OR BOTTOM EDGE OF SOLID SAWN RAFTERS SHALL EVALUATION REPORT. 15. APPLY I GOAT OF TAR BIASED WATERPROOFING TO EXTERIOR OF FOUND. - - -  -- -- -_- -_--- ---"-------I�----- -- __ -- z ILI. THE CONTRACTORS ALL B L O --- - - ----- -" - ---_-- ------ - -- -- Z NEEDED, UNLESS OTHERWISE SPECIFIED. ALL DIMEN51ONS ANc> CONDITIONS NOT BE OUT IN THE MIDDLE ONE-THIRD OF THE RAFTER SPAN. NOTCHES IN THE FROM FOOTING TO 2" ABOVE FINISH GRADE. I OUTER THIRDS OF THE SPAN SHALL NOT EXCEED ONE-51XTH OF THE ACTUAL 1.6.4. FIBERBOARD: FIBERBOARD U5ED IN STRUCTURAL APPLICATIONS EXTERIOR (2"x4") WOOD I,R-15 CAVITY BATT INSULATION MIN, R-VALUE = 13 (CAVITY) + 5 (CONTINUOUS) w PERTAINING ARE TO BE FIELD VERIFIED. RAFTER DEPTH. WHERE NOTCHES ARE MADE AT SUPPORTS THEY SHALL NOT SHALL MEET THE PROVISIONS OF AN51/AHA AIg4.l CELLULOSIC FRAME EXTERIOR WALL R-5 CONTINUOUS-RIGID - - - � W 16. NO CONCRETE OR MA50NR:Y WORK I5 TO BE PERFORMED IN TEMPERATURES _.. I 1 20. CONTRACTOR TO REMOVE 4 RELOCATE AS REQUIRED ALL EXISTING WORK EXCEED ONE-FORTH THE ACTUAL RAFTER DEPTH. 50REED HOLES ARE LIMITED FIBERBOARD OR ASTM G205 STANDARD SPECIFICATION FOR R-Vr,LUE -'�1NSULATION PER TABLE R40�2 1.2 - GLIMATE20NE 4' NOTE (h)''----�� Q o I 1 MANNER. IN DIAMETER TO ONE-THIRD THE ACTUAL RAFTER DEPTH AND THE EDGE OF THE CELLUL0510 FIBER INSULATING BOARD. OF 40*FCONCRETE AND FALLING, UNLESS APPROVED BY ARGHITEGT/EN6INEER. NO I/r-�_"j ^ � � - \/ _ - -_ \ �I,l+,�-_� \ _ _ _\, - - - - ' �''_-"� a � WHICH INTERFERES WITH NEW CONSTRUCTION IN A WORKMAN LIKE M NNE 1.8.5. STRUCTURAL PANEL SIDING STRUCTURAL PANEL SIDING USED IN CONCRETE SHALL BE PLACED ON FROZEN SURFACES. HOT W _ _____- -� ___ \ uw� a HOLE SHALL NOT BE CLOSER THAN 2 INCHES TO THE TOP OR BOTTOM EDGES. 21. ALL MATERIALS ARE TO BE INSTALLED A5 PER MANUFAaGTURER'SENT5 OF I'i. NO ADDITIVES SHALL BE PLACED IN CONCRETE UNLESS SPECIFIED BY ATER PIPE R-3 PIPE INSULATION MIN R-VALUE = 3 ,rES i \ 24. ES IN EP6E OF STUDS HALL NOT BE LOCATED IN THE TURAL APPLICATIONS SHALL MEET THE -- SPECIFICATIONS, UNLESS NOTED OTHERWISE. MIDDLE ONE-THIRD HIfZDHO1R HE STUD LEND HcNOTGHES IN THE OUTER THIRDS OF DEP TMENT OF COMMERCE VOLUNTARY FRODUQGT STANDARD IU5 ARCHITECT/ ENGINEER. INSULATION PER R405.4 4 R405.5 ------ - I', - w 22. PROVIDE FIREBLOCKIN6 AS PER NEEW YORK ACCE551B11LITY STANDARDS. THE STUD LENGTH SHALL NOT EXCEED 25% OF THE ACTUAL DEPTH. BORED (F5- 1), THE GOVERNING BUILDING CODE, AND ANY ADDITIONAL 18. PROVIDE BITUMINOUS JOINTSS BETWEEN SLABS AND FOUNDATION WALLS AND ALTERATIONS INVOLVING BUILDING ENVELOPE ASSEMBLIES SHALL II - Z HOLES SHALL NOT EXCEED 40% OF THE ACTUAL STUD DEPTH AND THE EDGE REQUIREMENTS AS SET FORTH IN APPLICABLE CODE EVALUATION WHERE EVER APPLICABLE. m 23. PLEASE NOTE THAT THESE PLANS ARE PROTECTED AGAINST ANY OF THE HOLE SHALL NOT BE CLOSER THAN 5/5" TO THE EDGE OF THE STUD. REPORTS. EX15TiNG CAVITIES SHALL BE � NOT BE REQUIRED TO COMPLY WITH THE REQUIREMENTS FOR NEW d NOTCHES AND HOLES SHALL NOT OCCUR IN THE SAME GR055-SECTION. ALL FOUNDATION FOOTINGS ARE TO $E A WALL, FLOOR 4 GE I L I NG CONSTRUCTION, PROVIDED THE ENERGY USE OF THE BUILDING I5 I o UNAUTHORIZED USE UNDER FEDERAL LAIN BY THE ARGHITEG'TURAL WORKS 2.2. FASTENERS AND CONNECTORS: ALL FASTENERS AND CONNECTORS SHALL Iq. UNLESS OTHERWISE INDIGA7rED, FILLED WITH NEW BAiT ~ COPYRIGHT PROTECTION ACT OF 19g0 ('AWCPA), WHICH HAS SEVERE PENALTIES. MIN. 10" DEEP PROJECTING 6" ON EACH 51DE OF THE FOUNDATION WALL. R-VALUE NOT INCREASED, WHEN EXISTING CEILING, WALL, OR FLOOR YES zo Fw- 25. FOR NEW WALLS, A PERFORATED 5HEARWALL 5Y5TEM 15 USED. THE CONFORM TO THE STANDARDS SPECIFIED IN M 2.2.1 THROUGH M 2.2.'1. INSULATION I CONTRACTORS ATTENTION IS DIRECTED TO THE APPLICABLE DETAILS, PROVIDE TWO #4 DEFORMED EARS CONTINUOUS IN THE FOOTING. ALL 4" THICK CAVITIES EXP05ED DURING CONSTRUCTION ARE FILLED WITHY � as GENERAL WIND PROTECTION CONNECTION NOTES: NOTES, AND TABLES ON FACE 0-005 4 0-004. THE FASTENING SCHEDULE 2.2.1. BOLTS: BOLTS SHALL COMPLY WITH AN51/ASME B 15.2.1 SQUARE AND CONCRETE SLABS TO HAVE 6»cb 10/10 WELDED WIRE REINFORCING. L_ -1 - INSULATION. PER R505.I.I, EXCEPTION #2 g (L ADAPTED FROM STANDARD FOR HURRICANE RESISTANT RES DENOTOALFRAME SPECIFIES THE READ NAILING FOR THE SHEATHING(ANY NAILING HEX BOLTS AND SCREWS (INCH SERIES). 20. FOR SECOND STORY ADD'ITIDNS, EXIST. FOUNDATIONS ARE TO BE VERIFIED -- - _ .. - I' Ic- m N CONSTRUCTION, S5TD 10 qq AND 2018 SBG HIGH WIND EDITION SPECIFICATIONS ON THE FLOOR PLANS SHALL SUPERSEDE THE FASTENING SCHEDULE). HOLDOWN5 OFERATE IN CONJUNCTION WITH THE PERFORATED 2.2.2. LAG SCREWS: LAC SCREWS OR LAG BOLTS SHALL COMPLY WITH ANSI/ AS IN SOLID # SOUND GONDITIION WITH AN EXIST. FOOTING OF MIN. I6 WIDE x 8 O.MP.L�f�4NG� 5T 41 M11, /�__�f�� � Z _j p CONSTRUCTION _ / / w I. A CONTINUOUS LOAD PATH BETWEEN FOOTIN65, FOUNDA':TION WALLS, 5HEARWALL SYSTEM (INSTALL AS PER APPLICABLE DETAILS 4 MANU. 5FEG.'s). ASME BI8.2.1 SQUARE AND HEX BOLTS AND SGREW5 (INCH SERIES). DEEP 4 3'-O" BELOW GRADE. - FLOORS, STUDS AND ROOF FRAMING SHALL BE PROVIDIED. HOEDOWN LOCATIONS ARE SPECIFIED ON THE FOUND./FLOOR PLANS. MECHANICAL CONNECTIONS: TO THE BEST-OF MY KNO"EDOE, EL�EF, /AND PROF�551 ONA�L JUDO MENT, I HESE PLANS AND o � � 2.2.5. 7RU55 METAL CONNECTOR PLATES: TRUSS METAL CONNECTOR PLATES SPEC I F I C.ATI ON5 ARE IN GOMFL I ANGE W I TH THE 2020 NY5 ENERO Y GON5ERVATI ON GONSTRUGTI ONl 0 z � 2. APPROVED CONNECTORS,ANCHORS AND OTHER FASTENING DEVICES NOT 26. COLUMN BEARING AS FOLLOWS: SHALL MEET THE REQUIREMENTS OF ANSI/T'PI I NATIONAL DESIGN I. ALL MECHANICAL GONNEGTrION5 SPECIFIED AS "SIMPSON" MAY BE - - INGLUDEV IN THE STANDARD BUILDING CODE, SECTION 2?306 OF IBC SHALL WOOD POSTING TO BE BLOCKED 50LIP TO FOUND. WALL w/ END GRAIN, STANDARD FOR METAL PLATE CONNECTED WOOD 7RU55 CONSTRUCTION, SUBSTITUTED WITH AN APPROVED EQUAL PRODUCT. GORE USING CHAPTER 4 [RE]. � T � � BE USED IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. TREATED WOOD 4 FLASHING. STEEL COLUMNS ARE TO BEAR UPON FOUND. THE GOVERNING BUILDING CODE, AND ANY ADDITIONAL REQUIREMENTS WALL w/ STEEL SHIMS 4 A MIN. 5/4" OF NON-SHRINK GROUT. AS SET FORTH IN THE MANUFACTURER'S CODE EVALUATION REPORTS. 2. THE SUBSTITUTION SHALL M1EET ALL OF THE MINIMUM CRITERIA SPECIFIED ----- 3. METAL PLATES, CONNECTORS, SCREWS, BOLTS AND NAILS EXPOSED BY "SIMPSON" MANUFACTURER. N N DIRECTLY TO THE WEATHER OR SUBJECT TO SALT CORR0510N IN COASTAL SECURE w/(2) I/2 ANCHOR BOLTS (4 LONG EXPANSION BOLTS ® fV 0 EXIST. WALLS 4 12" LONG HOOKED BOLTS ® NEW FOUND. WALLS). FOR ANY 2.2.4. METAL CONNECTORS WHERE METAL PLATE OR STRAPPING SIZE AND - - ---- --------_--- -------------""-- - ---------- w t i o AREAS SHALL BE STAINLESS STEEL OR HOT DIPPED GALVANIZED. „ 3. ALL LOADING CAPACITIES SHALL MATCH EXACTLY OR EXCEED VALUES I- Cv CV POSTING ® G.M.U. WALL SEE PLAN FOR REQUIRED REINFORGINC (® MIN. I6 GAGE ARE SPECIFIED, MINIMUM ASTM A653, STRUCTURAL QUALITY, INDICATED IN "SIMPSON" PRODUCT LITERATURE. THERE MAY BE SEVERAL TBI-E R�CI CLIMATIC, 4 GEOGRAPHIC. DE51CN CRITERIA a WIDE 3 COURSES OF SOLID BRICK MASONRY CENTERED 0 POSTING, U.O.N). GRADE 33 STEEL SHALL BE USED. OTHER METAL CONNECTORS SHALL [] 0 4. WHERE WINDOWS AND DOORS INTERRUPT WOOD STRUGTI.URAL PANEL MEET THE REQUIREMENTS OF THE GOVERNING BUILDING CODE AND ANY LOADING VALUES, CONTRACTOR SHALL CONTACT ARCHITECT IF ANY _ O O SHEATHING AND SIDING, FRAMING ANCHORS OR CONNEaTOR5 SHALL BE HOWEVER, WHEN COLUMN OR P05TIN6 15 PART OF THE LOAD PATH FOR USE ADDITIONAL REQUIREMENTS AS SET FORTH IN THE MANUFACTURER'S LOADING VALUES ARE LESS THAN WHAT 15 SPECIFIED BY "SIMPSON" ALLOWABLE DEFLECTION OF STRUCTURAL MEMBERS - _-- ------ PROVIDED AT THE TOP AND BOTTOM OF CRIPPLE STUD°S, HEADER 5T1JD5 IN A SHEARWALL, ALL ANCHORS MAKING AN ATTACHMENT ARE TO BE"w/ GODS EVALUATION REPORTS. _ _____ _____ ___ ___ GROUND SNOW LOAD 25 L55 _ PROJECT: STANDARD SHEARWALL HARDWARE (w/NOTED VALUES) 4 ANCHOR BOLTS, AND AT LEAST ONE STUD AT EACH SIDE OF OPENING. 4. ALL MECHANICAL GONNEGTfIONS SHALL BE HOT DIPPED GALVANIZED -- - - " _- --- - _- ---- - -------_-- U.O.N. WITH TOP GAPS ® STEEL COLUMNS TO BE MIN.Ya BENT PLATE 8 LONG ALLOWABLE 2.2.5. NAILS: NAILS 5HALL COMPLY WITH ASTM F 166-1 STANDARD STRUCTURAL MEMBER BASIC WIND SPEED 130 MNPH 5. RIDGE STRAPS SHALL BE ATTACHED TO EACH PAIR OF` OPPOSING w/ 6" RISE 4 W/(2) S�4"� BOLTS THROUGH CENTER LINE OF VERTICAL LEGS SPECIFICATION FOR DRIVEN FASTENERS: NAILS, SPIKES, AND STAPLES. 5. INSTALLATION PROCEDURE5 SHALL ALWAYS BE CARRIED OUT AS PER DEFLECTION _ M O LTZ RAFTERS EXCEPT WHERE COLLAR TIES OF Px6" OR 2"x<4" LUMBER 15 SET b" DIST., U.D.N. - ADDITIONAL INFO. IS FOUND ON PACE 0-003. MANUFACTURER 5FEGIFICA'TION5 OF THE PRODUCT BEING INSTALLED. ---- -- LOCATED IN UPPER THIRD OF ATTIC SPACE AND ATTACH TO EACH PAIR OF 2.2.6. PNEUMATIC NAILS AND STAPLES: PNEUMATIC NAILS AND STAPLES RAFTERS HAVING SLOPES GREATER THEN 3/12 EXPOSURE CATEGORY i B RAFTERS. SITE WORK SHALL MEET THE REQUIREMENTS OF THE GOVERNING BUILDING CODE 6. ALL FASTENING CRITERIA SHALL BE CARRIED OUT A5 PER MANUFACTURER L/IbO - ES I D E N C E AND ANY ADDITIONAL REQUIREMENTS AS SET FORTH IN THE SPECIFICATIONS OF THE PRODUCT BEING INSTALLED W/ No FINISHED GEILIN6 ATTACHED TO RAFTERS 6. UPLIFT CONNECTORS SHALL BE PROVIDED AT EACH 12A.NFTER BEARING. I. STAKEOUT IS TO BE PERFORMED BY A LICENSED SURVEYOR ___ _ SEISMIC DE51ON CATEGORY I B MANUFAGTURER5 CODE EVALUATION REPORTS. "7, VARIATIONS IN CONNECTOR CONFIGURATION SHALL BE APPROVED BY 2. VERIFY ALL 61VEN DATA ON DRAWINGS. IF THERE IS A DISCREPANCY, INTERIOR W4LL5 4 PARTITIONS H/I80 1. FLOOR TO FLOOR HOLD-DOWNS TO BE PROVIDED EVERY 48 AND EVERY ARCHITECT WEATHERING SEVERE I6" WITHIN 4' OF EXTERIOR CORNERS. RECEIVE CLARIFICATION FROM ARCH ITEGT/ENGINEER PRIOR TO PROCEEDING. 2.2.'i. SCREWS: SCREWS 5HALL COMPLY WITH AN51/ASME S I8.6.1 WOOD50REW5 (INCH SERIES). 5. ALL CONNECTORS SPECIFIED AS A "SIMPSON" TOP MOUNTED BEAM FLOORS 4 PLASTERED GEILIN65 L/360 ,,, 3. EXCAVATE AND BACK FILL FOR WORK INDICATED ON DRAWINGS. FR05T LINE DEPTH ! 3'-O 1600 ALVAHS LANE 5. SILL PLATE TO FOUNDATION ANCHORAGE;SILL PLATE 5+HALL BE ANCHORED HANGER 5HALL BE ALLOWED TO BE SUBSTITUTED WITH A TOP MOUNTED - - STOCKPILE TOPSOIL OBTAINED FROM STRIPPING DRIVEWAY AND BUILDING ASPHALT ROOFING SHINGLES ALL OTHER STRUCTURAL MEMBERS L/240 , CUTCHOGUE NY 11935 TO THE FOUNDATION WITH ANCHOR BOLTS HAVING A MIN. BOLT DIAMETER BEAM HANGER ONLY ALON�6 WITH SPECIFICATIONS LISTED ABOVE. SITE. STOCKPILE ALL EXCAVATED MATERIALS. I. ALL SLOPED ROOFING SHINGLES SHALL BE GAF-GLASS-A ASPHALT ROOFING _ TERMITE MODERATE TO HEAVY � OF �" AND 5NV'x�" WASHERS. A MINIMUM OF ONE ANCHOR BOLT 5HALL BE 5HIN5LE5 OR APPROVED EQUAL. 6LA55 WINDOWS AND DOORS. PROVIDED WITHIN b TO 12 INCHES OF EACH END OF EACH PLATE. ANCHOR 4. NEW AND EXI5TIN6 BACK FILL MATERIAL ARE TO BE FREE OF WEEDS, TREE I. ALL 6LA55 TO BE INSULATED LOW-E, UNLE55 OTHERWISE SPECIFIED. F EXTERIOR WALLS YJ/ PLASTER OR STUCCO FINISH H/360 BOLTS 5HALL HAVE A MINIMUM EMBEDMENT OFT' IN CONCRETE/MASONRY ROOTS, ROCKS, AND DEBRIS. ALL SURPLUS MATERIAL THAT 15 UNSUITABLE 2. 5HINOLE5 SHALL BE APPLIED OVER 15# BUILDING FELT, UNLESS OTHERWISE __ __-_ _- 1ICE BARRIER REQUIRED YES - DRAWING TITLE: _FOUNDATIONS. ANCHOR BOLTS SHALL BE LOCATED WITHIN 12" OR CORNERS FOR $AGK FILL MATERIAL 5HALL SE REMOVED FROM SITE. NOTED. ALSO, GONTRAGTORS OPTION TO APPLY GAF-WEATHER-WATCH ICE 2. GLASS DOORS AND WINDOIWS SHALL NOT BE INSTALLED UNTIL PROPER, - -- ---- - ---.-- AND AT SPACING NOT EXCEEDING 4' ON CENTER. AND WATER BARRIER FROM EDGE OF EAVE TO 24" IN51PEE EXTERIOR WALL CLEARANCES ARE PROVIDED,. EXTERIOR WALLS - WIND LOADS !^I/ BRITTLE FINISHES L/240 GENERAL NOTES 5. PROTECT TREES WITHIN EIGHT FEET OF THE BUILDING. LINE. 4 24" FROM ALL VALLEYS, AND ROOF FLASHING CONDITIONS. 3, ALL SLIDING CLASS DOORS, 5KYLIOHT5, AND ANY 6LA55 UNIT INSTALLED „ EXTERIOR WALLS - WIND LOADS W/ FLEXIBLE FINISHES L/120 ENERGY TABLE 3. PROVIDE FLASHING NECESSARY FOR WATER TIGHT AND WEATHERPROOF WITHIN 18 OF FINISHED FLOOR SHALL BE OF INSULATED TEMPERED CLASS, CODES AND REFERENCE STANDARD: UNLE55 OTHERWISE NOTED. - ---- I. ALL NEW WORK PERFORMED SHALL CONFORM TO THE 2020 NEW YORK CONSTRUCTION. _ _ _ _ STRUCTURAL DESIGN CHARTS STATE BUILDING CODE, 2020 NEW YORK STATE RESIDENTIAL CODE, 2020 ELECTRICAL: 4. ALL OLA55 UNITS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH - - ---- - --- -- ----- - NEW YORK STATE PROPERTY MAINTENANCE CODE, AND 20)20 NEW YORK I. ALL NEWLY INSTALLED ELECTRICAL WORK OR APPLIANCES SHALL CONFORM 4. ROOFING 15 TO BE APPLIED IN STRICT ACCORDANCE WITH MANUFACTURER'S MANUFAGTURER'5 5FECIFIGATIION5. STATE ENERGY CONSERVATION CONSTRUCTION CODE. TO 201-1 NATIONAL ELECTRIC CODE, NFPA -70 AND 2020 NEW YORK STATE SPECIFICATIONS. ii�� ENERGY CONSERVATION GONSTRUGTION GORE. STItUGTURAL DES I C N LOADS 2. REFERENCE STANDARD USED FOR ALL WOOD FRAMING, CONNECTIONS OF 5. NAILING OF ROOFING SHALL BE TO CODE. 5. ALL WINDOWS TO BE CAULKED AND SEALED AS PER NEW YORK STATE - - - _ --- - ENERGY CONSERVATION CONSTRUCTION CODE. WOOD FRAMING AND CONNECTION TO FOUNDATION - 2018 WOOD FRAME 2. CONTRACTOR WILL FURNISH A FIRE UNDERWRITERS CERTIFICATE UPON I PAGE: CONSTRUCTION MANUAL BY THE AMERIGAN FOREST 4 PAPER ASSOCIATION COMPLETION OF WORK. 66. CORPERMITR�OV51ON RE5157ANT II GAGE ROOFING NAILS AND 16 GAGE STAPLES ARE 6. PROVIDE FLASHING PANS UINfDER ALL SLIDING 6LA55 DOORS, WINDOWS, OR USE I LIVE LOAD I DCAD LOAD (AF4PA) AMERIGAN WOOD COUNCIL (ANC)' 3. SMOKE DETECTORS, IN CONFORMANCE WITH NFPA 72: ANY OTHER TYPE OF CLASS UNIT WHEN WITHIN 6" OF AN EXTERIOR SURFACE. ------ - GENERALLY,VERIFY OR PROVIDE HARD WIR® '1. PROVIDE (2) LAYERS OF 15# ASPHALT BUILDING FELT UNDERLAYMENT FOR EXTERIOR BALCONIES 40 psf 15 psf 3. ALL PLUMBING WORK SHALL CONFORM TO THE 2020 NE:W PORK STATE '1. ALL EXTERIOR DOORS ARE: TO BE WEATHERED STRIPPED AND PROVIDE ALL I :1SMOKE DETECTORS w/BATTERY $AGK-UP IN; 2:12 FITGHE5 TO 4:12 PITCHES --- ---- - -- U-002m0ml PLUMBING CODE. SCREENS AND HARDWARE NECESSARY FOR PROPER FUNCTION OF SUCH UNITS. DECKS 40 psf 15 psf 4. ALL MECHANICAL WORK SHALL CONFORM TO THE 2020) NEW YORK STATE A. EACH SLEEPING ROOM 5. ASPHALT SHINGLES SHALL BE TESTED TO DETERMINE THE RESISTANCE OF 6. ALL CLASS 15 TO BE FREE OF SCRATCHES AND IMPERFECTIONS. CLASS - - -- -_- MEGHANIGAL CODE AND 2020 NEW YORK STATE FUEL GA�5 CODE. THE SEALANT TO UPLIFT FORGES U51N6 A57M D 6551. SHOULD BE GUARANTEED BY THE MANUFACTURER FOR A PERIOD OF 5 YEARS. FA55ENGER VEHICLE GARAGES 50 psf AS PER PLAN B. OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF --- DATE: 01 20 25 5. ALL ELEGTRIGAL WORK SHALL GONi'ORM TO 201'1 NATIONAL ELECTRIC q. ALL WINDOWS TO BE 6LOBjAL WINDOWS SYSTEM. IF CONTRACTOR 15 TO UNINHABITABLE ATTICS WITHOUT STORAGE � � 2 OF 7 CODE, NFPA -10 AND 2020 NEW YORK STATE ENERGY CONNSERVATION THE BEDROOMS (GENERALLY THE HALLWAY) MEGHANIGAL, FUEL OAS: SUBSTITUTE WITH ANOTHER WIi`I:DOW MANUFACTURER, IT IS THE RESPONSIBILITY (MAX CLEAR HOT < 42") 10 psf 15 psf CONSTRUCTION CODE. OF THE CONTRACTOR TO VERIFY THAT THE CHARACTERISTICS OF THE WINDOW - G. EVERY LEVEL OF DWELLING UNINHABITABLE ATTICS WITH STORAGE GYPSUM WALL BOARD I. MECHANICAL AND FUEL 6A5 SYSTEMS SHALL COMPLY w/ THE MATCH THE CHARACTERISTICS OF THE GLOBAL WINDOWS SYSTEM WINDOW „ 20 psf 15 psf 1. GYPSUM WALL BOARD SYSTEMS SHALL BE OF A TAPE JOINT AND JOINT (BASEMENT, FIRST FLOOR, SECOND FLOOR,ETC.) NYS MECHANICAL GORE AND FUEL GAS CODE SPECIFIED. THE GHARAGTERIS5TIG5 ARE AS FOLLOWS, BUT NOT LIMITED TO: (MAX CLEAR HOT > 42 ) ____ _ - - - DESIGN PRESSURE, ROUGH OFIENING, U-FACTOR, LIGHT AREA, VENT AREA, AND HABITABLE ATTICS 4 COMPOUND METHOD. EGRESS REQUIREMENTS. ATTICS SERVED BY FIXED STAIRS 30 psf 15 psf 2. ALL MECHANICAL SYSTEMS, APPLIANCES, 4 EQUIPMENT SHALL BE LISTED, � I 2. ALL OYP5UM BOARD SHALL BE 1/2" ON WALLS AND GEILIN6, UNLE55 INSULATION LABELED, 4 INSTALLED IN ACCORDANCE w/ MANUFACTURER'S SPEC.'S 4 CODE. OTHERWISE NOTED. WATER RESISTANT (W.R) AT $ATHROOWS AND WHERE I. ALL EXTERIOR WALLS AND ROOFS SHALL BE INSULATED WITH FOIL FACED 10. WINDOWS IN TUB/SHOWER ENCLOSURES AND WITHIN STAIRWAYS 5HALL BE I ROOMS OTHER THAN 5LEEPIN6 ROOMS 40 psf 15 psf I" �. G� DEEMED APPLICABLE. FIBERGLA55 BATT INSULATION BY JOHN MANVILLE OR APPROVED EQUAL. 3. ALL FUEL GAS SPACE HEATING APPLIANCES IN RESIDENTIAL BUILDINGS TEMPERED GLASS. - !'' FOIL TO BE PLACED TOWARD WARM SIDE. SHALL BE EQUIPPED w/FLAME SAFEGUARD DEVICE WHICH SHUTS OFF THE FUEL II. EXTERIOR GLAZING SHALL IBE PROTECTED FROM WINDBORNE DEBRIS. i O 'A. PO �'gI 5LEEPIN6 ROOMS 30 psf 15 psf 3. 5/8", ONE HOUR RATED, TYPE 'X' GYPSUM BOARD ON GEIILING AND HALLS SUPPLY TO THE BURNER WHEN THE FLAME OR PILOT LIGHT 15 EXTINGUISHED. GLAZED OPENING PROTECTION SHALL MEET THE REQUIREMENTS OF THE LARGE _- -_ - L__ ) 0��� '��, OA (WHERE APPLICABLE) AT HEAT PRODUC:IN6 EQUIPMENT TO EXTEND THREE FEET 2. PROVIDE 2" R-10 RIGID FOAM INSULATION FOR EXTERIOR FOUNDATION MISSILE TEST OF A5TM EIgg6 AND ASTM E1886 AS MODIFIED BY 2020 NY5 BG I r I n �' c WALLS FROM b" BELOW GRADE TO 24" BELOW GRADE IF DESIRED BY 4. SUPPLY 4 RETURN DUGT5 OR PORTIONS THEREOF NOT LOCATED SECTION 501.2.1.2.1. GARAGE DOOR GLAZED OPENING PROTECTION SHALL MEET STAIRS 40 psf 15 psf ) 1 ` � 'A�'11•`"f-!''_,'��O IN EACH DIRECTION BEYOND THE UNIT(..). ALSO AT HEAT PIROVUGINGREGU z 'V ,,I.•,` '" t EQUIPMENT, CONCRETE FLOOR OR IF PLACED ON WOOD FR ME, INSTALL CONTRACTOR OR OWNER. CARE SHOULD BE TAKEN NOT TO DAMAGE TO ANLETELY R-VALUEINSIDE OF AT LE S NYS EGG R403 355 ENVELOPE SHALL BE INSULATED ANSI/DASMA �TS OF AN APPPROVED IMPACT-RESISTANT STANDARD OR - -"- a, Ia, �) 1 I CONCRETE PANELS OF 5/8" THIGKNE55 MINIMUM. FOUNDATION WATERPROOFING. # GUARDRAILS AND HANDRAILS 200 psf 15 psf * "." ->'. I 12. AS AN ALTERNATIVE TO NOTE II ABOVE, WOOD STRUCTURAL PANELS WITH �� �,4 4. FINISH JOINTS, J-BEADS, NAIL DIMPLES, CORNERS, AND EDGES SHALL BE 5. GENERALLY, UNLESS NOTED OTHERWISE, INSULATE AS FOLLOWS: DUCTS 3 O 4 GREATER, LOCATED IN ATTIC: R-8 A THICKNESS OF NOT LE55 THAN AND A SPAN OF NOT MORE THAN 8 SHALL � �,� TAPED AND RECEIVE THREE GOATS OF JOINT COMPOUND. ALLOW 24 HOURS - q" R-30 FOR FLAT CEILINGS DUCTS UNDER 3"4', LOCATED IN ATTIC: R-6 BE PERMITTED AS GLAZING PPROTEGTION. PANELS SHALL BE PRECUT AND �' 037 .� j TO DRY BETWEEN GOATS. FINAL GOAT TO BE SANDED SMOOTH. - 6.25" R-30G FOR VAULTED AND CATHEDRAL CEILINGS DUCTS V 4' 4 GREATER, OTHER PORTION OF BUILDING: R-6 ATTACHED TO THE FRAMING SURROUNDIN6THE OPENING. PANELS SHALL BE ROOF LOADING (LIVE = GROUND SNOW LOAD) 25 psf 15 psf 91.�' �� 5.25 R�2 FOR 2 x6 WALLL CONSTRUCTION CONSTRUCTION DUCTS UNDER 3 4', OTHER PORTIONS OF BUILDING: R-4.2 PERT HE AND HORACE METTHHOD SELECTEDACHMENT IN ACCORDANCE W TH TTABLEHARE ED AS Ii= - - - A O F N� 5. METAL CORNER BEAD TO BE USED ON ALL OUTSIDE CORNERS AND AROUND - R301.2.1.2. ATTACHMENT HARDWARE SHALL BE PERMANENT ALL OPENINGS. - 5.25" R-21 FOR FLOORS CORROSION-RESISTANT AND TTHE ANCHORS SHALL BE PERMANENTLY INSTALLED "ALL STRUCTURAL DEVON CONSIDERATIONS ARE IN CONFORMANCE WITH 6. FASTEN GYPSUM BOARD A5 PER FASTENING SCHEDULE ON PAGE 6-003. ON THE BUILDING. ASGE 7-16 (MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES) - OE I ERAL 5 I ME30L E I : r EXISTING TO BE DEMOLISHED NEW PARTIAL HEIGHT d — WOOD FRAME (L.G. 5TL. 4Z7 Q WHEN APPLICABLE) EXISTING TO REMAIN, O �-�--�{ D Lu NEW WOOD FRAME (I..&. NEW FOUNDATION WALL � � �N J � 5TL. WHEN APPLICABLE) co M NEW I-HR FIRE RATED © MIN. (2) 2"x4" STRUCTURAL � c Lo e P05T FOR 4" WALLS WOOD FRAME (L.G. .iTL. WHEN APPL I GABLE) (MIN. (2) 2"xb" STRUCTURAL �'• (d POST FOR 6" WALLS), U.O.N. _—_ _.' -- _ O NEW 2-HR FIRE RATE'_D co WOOD FRAME (L.G. 5TL. MECHANICAL SYSTEMS: --- -- — — — — — — - — — O CV z O WHEN APP IGABLE) I. INSTALL/REROUTE ALL EQUIPMENT AS PER MANU. SPEG.s — — — _ i c� 2.MAINTAIN 30"x30" CLEARANCE IN FRONT OF MECHANICAL _ � Lo.• r-UNITS r- AS PER NYS MG 506.1 cc 5.MAINTAIN ALL APPLICABLE VENTING CLEARANCES -- — — — O G O +�-+ C� REQUIRED PER NYS MG 504. I O O m 4.IF APPLICABLE, DISCONNECT, REROUTE, E RECONNECT -O O `- EQUIPMENT TO EXIST. PIPING AS REO.V. I PROPOSED � 4-1 coLn HOT TUB 15" SPA Q 0 2 O TYPICAL MECHANICAL AREA NOTES: 4a.0 S.F. BENCH I. FOR WV. FR. FLOOR - PROVIDE 1/2" GONG. BD. BY I OUNITE DEMOLITION NOTE: PROVIDE SHORING AND SUPPORT TO ALL AFFECTED FOP,OQ . R. EQUAL) `-�f'A 2. FOR WD. FR. WALLS - PROVIDE (I) LAYER OF 5/8" STRUCTURAL MEMBERS PRIOR TO THE COMMENCEMENT TYPE "X" OYP. BD. UL U505 (OMIT ON GONG. WALLS) I $ OF ANY DEMOLITION OR CONSTRUCTION. 5. WHEN NEW, INSTALL FURNACE/BOILER A5 PER MANU. -� . A_401 SPEC.'s AND A5 PER NY5 MECH. AND FUEL OAS CODE \ 4. WHEN EXIST., MECH. EQUIP. SHALL BE VERIFIED THAT IT CONFORMS TO NYS MECH. AND FUEL OAS GORE \` 5. COMB. AIR VOLUME AS PER MANU. SPEG.'s - PROVIDE - - L REMOVE BILCO FRESH AIR INTAKE FROM EXTERIOR - — -- — —� DOORS AND 6. MAINTAIN OR PROVIDE FURNACE/BOILER ELECTRICAL 70 STAIRS ;PROVIDE EMERGENCY SHUT OFF SWITCH V NEW ACCESS HATCH "1. FOP, GAS SERVICE, PROVIDE 6A5 SHUT OFF 5WITGH REMOVE FLUE WITHIN WOOD DECK I Q II _____ __- RELOCATE EXISTINO OUTDOOR - r I � I 8. LOCATE MECH. EQUIP. TO ALLOW FOR PROPER I SHOWER CLEARANCES AS PER GORE -- n REMOVE AND Q. PROVIDE 5" FLOOR DRAIN IF REOV BY EQUIPMENT 4 -i ® `j� NEW STAIRS W/ < REPLACE W/ WIDER CONNECT TO SANITARY SYSTEM AS PER NYS I I I � i ® NEW HIDDEN WINDOW PLUMBING CODE I X- ACCESS _ ___ ( 10.APPLIANCES JOINED THROUGH A COMMON NATURAL - I'-O" j �` DRAFT VENTING SYSTEM SHALL COMPLY WITH ALL `t Q ---?fp HATCH .ICI I" 12'-6" i SECTIONS OF 2020 NYS RG 6242.1. L NEVA _ _ L—�_ -- -- ---- REMOVE SHOWER - �' - ------.5---- - C) REMOVE # EXIST.AS 1 _ii REPLACE TURO GAS BATHROOM METER - L--��-- - - i .ram^ -- - - ` EW 3' X b'8" v J REMOVE AND 1 f=_ =� 0L STEEL DOOR 71 / \ REMOVE WINDOW RZEPLAGE W/WIDER III 11 n 1 o AND WALL FOR `\�� EXIST. BATH EXIST. EXIST. GAS WINDOW yi -- DOOR OPENING ` II 54.1 SF. zJ WATER W/H 8 BOILER , 66 REMOVE \J = REMOVE WALL RELOCATED FILTER 1 II EXIST. KITCHEN DOOR ' ,. FOR DOOR BOILER to >)/ OPENING VENT EXIST. 210.0 5F. _ UNEXGAVATED REMOVE ALL _____ AREA KITCHEN GABS AND 2_6 _ APPLIANCES L --- 6 EXIST. --7 BASEMENT DN 155A SF. -� ---_ EXIST. -�_ — i _1 LAUNDRY EXIST. EXIST. ELEG. ROOM MUDROOM 33.4 SF. 42.4 SF. EXIST. PANEL i ELEG. EXIST. UP METER ACCESS OPENING w Z Qa O w Q O w Z w Z ( m g O n. 0 Z w EXIST. DINING 0 ~Q ROOM m N Z N U J Q � g O — V Z EXIST. LIVING ROOM 400 5F - — - --- - EXIST. N N 11.3 5F. Fw-• N N GL. LO- GRAWLSPAGE I PROJECT: EX15T. M 0 LTZ 11.0 SF. RESIDENCE EXIST. Io3ESF. 1600 ALVAHS LANE CUTCHOGUE, NY 11935 DRAWING TITLE: EXIST. PROPOSED DEMOLITION PLAN PROPOSED FOUNDATION PLAN EXIST. COVERED PORCH 160.0 SF. ❑ ❑ ❑ ❑ DATE: 01/20/25 3 OF 7 lz P() � FROFC&Er�) IDEMOL.I TI ON FIRST FLOOR PLAN FROPOSEI7 FOUNDATION PLAN tp �-9 a37410 yo SCALE: 1/4" = 1'-0" SCALE: 1/4" = I'-O" TF OF 14 i O E N E i _ 5�*r�1 5 O L= ' E %r : ALL NEW WI NDOW5 SHALL BE ANDERSEN; INSTALL AS PER MANU. 5PEG.'s. SEE DOOR 50HEDULE FOR ALL 6LA55 DOORS FROM SAME MANUFACTURER FINAL DIMENSIONS FOR FRAMING OF WINDOWS TO BE PROVIDED BY WINDOW MANUFACTURER NEW PARTIAL HEIGHT /�""--\ �� /- /�' / / \ ** CONTRACTOR TO VERIFY MANUFACTURER DIMENSION WIDTHS FOR ALL MULLED WINDOWS a _ EXISTING TO BE DEMOLISHED , WOOD FRAME (L.G. 5TL. V \/ V \/ \/ �/ Q WHEN APPLICABLE) WINDOW CHART - � EXISTING TO REMAIN PROPOSED POOLNEW FOUNDATION WALL UNDER SEPARATE APPLICATION ) - - - ------ - - - --------- - ---- -- -- - ---- EGRESS CLEAR ---- - - - - -- - ------- ---- Lu O NEW WOOD FRAME (L.G. ( W 5TL. WHEN APPLICABLE) I� WINDOW DIMENSION OPENING LIGHT VENT J O AG COUNT TYPE - # T_ . PROV. PROV. (+) MODEL CMP. , - -e DTH REQD:_20" PER U'l1(T PER UNIT NOTES Q N NEW I-HR FIRE RATED MIN. (2) 2"x4" STRUCTURAL _-____ z � �� -WIDTH HEIGH'P� HEIGHT 6'D: 5: 2 S.F. / \ �" � - _ POST FOR 4" WALLS � � � l�•F•) (5.�.) . WOOD FRAME (L.G. 5TL. - ____ -_ -- -_- -- - - - -- -- - - -- -- 0) OPEN REO D: 5."1 . 77� WHEN APf'LIGABLE) POIN.ST(FOR 6" WALLS)U.O.N. [-STRUCTURAL th _ _ - _� � CASEMENT A IL NDERSEN 3'-4 4;-II -- ------ O w p „ 12" COPING F: --- B CASEMENT ANDERSEN 4-O - - -- -- L NEW 2 HR. FIRE RATED 4-I I � WHEN APPLICABLE) O C N O WOOD FRAME (L.G. 5TL. /\ / i "I/8 \' I -__ \ a .� � � � PROPOSED POOL DECK -/ �•, �,� �\• ?� X U N ( UNDER SEPARATE APPLICATION ) O O p m •z C4 i DULE d coDOOR SGHE --- - - Q 0DOOR -- _ MATERIAL TAG DESCRIPTION MANUFACTURER FIRE RATING Ia 45 MIN. RATED NOTES WIDTH HEIGHT O F- ! d SELF-CLOSING O w � V - -'� -- - 3 -- -_ -_-----_ 4 < O FIRST FLOOR' NEW: 4'-0" HIGH MN 101 51NOLE SWING-- ----�----_- JELD-WEN 3'-O" 6'-8" • --I ----- -- �� POOL PROP. all HOOP FENCE - - --- - - -- ___ U - - POOL COPING TO 102 SLIDER ANDERSEN 6'-011 -1'-10" • • MATCH DECK HOT�IJB "O 1 1 4a S.F. lu PROPOSED Q DECK v J \ / I 285.5 S.F. RELOCATED 51x4c Q 4 \ / OUTDOOR SHOWER t- (OPEN TO ABOVE); 4' Oy2" 2' 2}/2" �-� ® r 4"x4" P.T. POSTS w/ to WOOD PANEL SIDING (2) '7.5" L FLUSHED 2 A HDR. -_ v F-4--0" ICJ m O 102 2 EXIST. 2X8 RAFTERS MOPIi • 5 F. 5 BATH D 5X5 COLLAR TIES (2)"1.5 LVL FLUSHED - f 34.1 SF. HDR. _ - - � MODIFIED� I I EXIST. i - Q d� BATHROOM FLOOR PLAN, NOTES KITCHEN EXIST. Lu b F 210 S.F. I [L 101 BEDROOM DOOR NOTE: ILL 6„ 0 200 5F. O I. INSTALL NEW INTERIOR DOORS WHEN GALLED OUIT Qo Qoin ON PLANS BY 'JELD-WEN' (OR EQUAL). r; 2.INSTALL NEW EXTERIOR DOORS WHEN GALLED OIUT Z ON PLANS BY 'THERMATRU' (OR EQUAL). EXISTING EGRESS; 5.8 5. NOTE DOF-5 NOT INDICATE EACH NEW DOOR EXIST. S.F. CLEAR OPEN; 27" < z PROPOSED;SEE DE516NATION5 8 DOOR 50HEPWLE. _ a O CLEAR HEIGHT; 31 0- 4.PLACE DOORS 4 MIN. FROM PERPENDICULAR 3 DN CLEAR WIDTH w Q WALL5, U.O.N. = 0 5. INSTALL AS PER MANU 5PEC..'s � Z 6.PROVIDE (2) 2"xl0" HDR., U.O.N. .K-3'-b" 2'-6" 4'-0" WINDOW NOTE: O I CASEMENTIDOUBLERS SHALL BE ANDERSEN :3. M �H�N6o0R 6LID[NO (ASNOTED). �.XIST. 0 O CL CL INSTALL AS PER MANU. SPEC.'S. LAUNDRY EXLT EXIST. O 2.NOTE DOES NOT INDICATE EACH NEW WINDOW PRZOPOSED; ROOM / /� MURROOM Z w SEE DE51ONATIONS d WINDOW SCHEDULE. 55.4 5F - --f� -- �2.4 SF �' O Q 5.FOR 5UBSTITUTION5, 5EE NOTE #a IN "6LA55 WINIDOWS EXIST. 18.17 SF. N O AND DOORS" ON PAGE 6-002. _UP 4.ALL CASEMENT WINDOWS TO HAVE STRAIGHT AFRM HINGE. 5. ALL DOUBLE HUNG WINDOWS TO BE TILT WASH 6.IN GENERAL, TEMP. GL. SHALL BE PROVIDED: EXIST. = ` Q p � 6.1. FOR ALL SKYLIGHTS d OPERABLE PANELS OF WINGING 5 IDING d• BIFOLD DOORS 14.8 5F. 0 5 L O 6.2. WITHIN IS" OF F.F. 6.5. WITHIN 24" OF A DOOR -- 6.4. WITHIN STAIRWAYS 3 WITHIN 56" OF A LA�NDIN6 6.5. WITHIN TUB/SHOWER ENCLOSURES - - 6.6. SEE AL50 GENERAL NOTES ON PAGE 0-002 EXIST. � 1 � -"-- - It L - 1. WINDOW FALL PROTECTION SHALL BE PROVIDED PER WI NYS R512.2 FOR OPERABLE WINDOWS WITH s4 ITH SILL HEIOHT5 G LE-55 THAN 24" ABOVE F.F., THAT ARE MORE THAN 12° s sF. EXIST. [xi N � ABOVE GRADE OR THE ADJACENT SURFACE AT THE GL. � N BUILDING EXTERIOR. 34.8 EXIST. DINING O Q O O EGRESS NOTE: ROOM 0 EXIST. IN COMPLIANCE WITH NEW YOR.K STATE BUILDING 165 5F a U - - r-L. PROJECT: CODE, SECTION R510.2.I;THE FOLLOWING MEANS OFF 15.6 5F. IL EORE55 SHALL BE FOLLOWED: V lz -- _NET CLEAR OPENINO........... 5.'I M 0 LTZ S.F. - - - ��® ,,.---EXIST. NET CLEAR HEIGHT............... 24' MINIMUM -~ DN RESIDENCE NET CLEAR WIDTH................. 20" MINIMUM _ • ®V N NEW FLOOR: w O I. NEW J" PLYWOOD 5U5FLOOR BENEATH (GLUE 4 SCREW); EXIST. LIVING - _-- 2'-2" 4 EXIST. ROOM 5GREW PERIMETER OF SHEATHING 6" O.G. 4 12" CO.C. ® EXISTING EGRESS1 1NrRlOR•� - Gam- 1600 ALVAHS LANE 2. W FIN15HEM FLOOR TO MATCH E 15TING 11.5 5F. �0 c ., EXISTING EGRESS; NEW BASEMENT DOOR: '1.0 S.F. CLEAR ` O S.F. CLEAR OPEN; 24.'i5" OPEN; 24."f5" CUTCHOGUE, NY 11935 O I. NEW HIDDEN ACCESS DOOR WITHIN DECK OVER INEW CLEAR HEIGHT; 41" i- LEAR HEIGHT; 41" BASEMENT STAIRS. EXISTING R DRAWING TITLE: CLEAR WIDTH � � ` CLEAR WIDTH 2.INSTALL AS PER MANU SPEC:.'e �______ _ CONDENSER >;t �t L EXIST. ;; NEW TILE FLOOR: EXIST. O I. NEW TILE FINISH (H.O. TO SELECT) UPON BEDROOM PROPOSED FIRST FLOOR PLAN ILO 5F. 159 SF. EXIST. • ° EXIST. 2.ONE LAYER THIN(H. (LEVELED PROPERLY) UPONd BAEX THROOM PROPOSED SECOND FLOOR PLAN 5.NEW " g T SF BEDROOM DUROGK GEMENTBOARD (OR EQUAL) UPOPN I TO 5F. 4.NEW " PLYWOOD 5UBFLOOR BENEATH (GLUE 4 S..--'GREW); REMO - 4 m SCREW PERIMETER OF SHEATHING 6" O.G. 4 12" IO.C. ® EXIST. REPLACE INTERIOR. DEN BATHROOM. SF. FIXTURES' - PAGE: EXIST. 2X6 G.J. T61 FLOOR JOISTS 5154T'ERED EXIST. 2X6 RAFTERS EXIST. 2X6 RAFTERS _ ® I6 O.G. ® I6" O.G. A .10 02" 0 1 EXIST. 2X6 G.J. EXIST. 2X6 G.J. EXIST. ® 161, O.G. Gam. DATE: 01/20/25 4 O F 7 n R ® EXISTEKED PORCH �_ •� C- 160.0 5F. 0) PROi=05E17 FIRST FLOOR PLAN SF_(f-,ONI7) FLOOR PLAN °F N�� SCALE: 1/4" = 1'-0" SCALE: 1/4" = P-O" ELEVATION NOTE5 NEW DIRECT VENT FOR EXIST. MEGH UNIT: 0NEW WOOD FRAME DECK STAIR O INSTALL NEW VENT AS PER MANU. 5PE0.'5 FOR EXI5TIN6 OAS BOILER. IN FULL CONFORMANCE w/ a Q VENTING CLEARANCES REQUIRED PER NY5 MO 804. SEE ALSO NOTE ® FLOOR PLANS. O2 NEW WINDOWS 6 DOOR HATCHED AREAS INDICATE NEW 51MINO TO MATCH Lli O J f6 EXISTING (TYP) Cy) O3 NEW 2" AZEK WINDOW TRIM Q a-' N 0 c In O � � O REBUILT OUTDOOR SHOWER, OPEN TO ABOVE co O C N z 0 O RESERVE a. •� Lr) V 2 X � N O 4-+ C1 -c p - -J n J O c B � Q a O W 4-J -0 U �L - -- �--I�- -_ _ LLd-L U LLLML 411 ILL QL1! , B w.J � 102 \ �O� I o l t ; 4� ox _ m iv m_ m � F F. �n ---- - 11 I '� F.F. 3' MIN. 1 M u r F PROPOSED &UNITE — — — — — — Q Oz PROPOSE:17) EAST ELEVATION (REAR) z s � J SCALE: I/4" = I'-O° i R0F05F-17) NORTH ELEVATION (LEFT SCE) E) m g o a 50ALE: 1/4" = 1'-0" z0 w � I Q o a M N z w N V ALLOWABLE 1-16T. PER PYRAMID LAW 0 F- 0 z a a* Lo N N H N N / O O O PROJECT: EXISTING ROOF M 0 LTZ UNDER GO #Z24332, RESIDENCE 05/Ob/gb; 1600 ALVAHS LANE / CUTCHOGUE, NY 11935 DRAWING TITLE: PROPOSED EXTERIOR ELEVATIONS m PROPOSED POOL SECTION DESIGN DETAILS IL -- - ---_- �❑III '��❑ 0❑ 45 PAGE: A 0 :-AL 0 'a -2 ■ I I DATE: 01 20 25 i !II 4 — - ---- / / 5 OF 7 it I 4 I Iil l �Q, ` '',V� G ju GRADE PROPOSED &UNITE — — — — — — / •�A 037 , HOT-TUB S` o vo - FROFOSF-17 50J7H ELENVA7I ON (R I OHT 5117 ) FROPOSE1�) NEST ELEVATION (FRONT) 5GALE: 1/4" = I'-O" 50ALE: 1/4" = P-O" 11 STRUCTURAL PLAN NOTES O FOUND $ POSTS FOR WD. DECK: Q 6"xb" P.T. POST UPON 12"0 P. GONG. PIER '-'-' LLJ FOR WOOD STAIRS ® GRADE: cu O2 4" THK. P. GONG. PAD 8" WIDE x REG'D LENGTH UPON cy) 6" GRAVEL UNDER 2"xl2" P.T. STAIR STRINGERS ® m CV MAX. 16" O.G.,U.O.N. (MIN. 5 STRINGERS) Q a-' (�3 DBL. F.J. � — — — � _ � RESERVE — O I'-3"�` 4'-6"-�`I'-3" TYPICAL LEDGER BOARD a !XT. DECK: 9 L C �' 4 1. (1) 2"x P.T. BD. TO MATCH DEPTH OF J015T5 PROPOSED a z O " 2. SECURED w/ (2) 5/8 0 x 5" LONG H.D. GAL. LAG BCOLTS X� HOT B • • = � ,� � V � ® I6 O.G. 4a.0 B.F. cc 5. INSTALL H.D. 6ALV. J015T HAN5ER R 5 BY 51MPSON ((O 4 JI GUNITE �' G X CV EQUAL) Q 5PA r O a--+ 4. PROVIDE FLA5HIN6 TUCKED UNDERNEATH SIDING 4 z NEW 2 xb .c O m BENT OVER TOP EDGE OF LEDGER BD. 'm ® 16" O.G. c O ca 5. SEE NOTED DETAIL Q Q a 2: O PROV/HAN6ER5 DBL. F.J. } J WOOD n , ILU� IL Ic Q4 -I v� DECK 8 W ti IL u. � � d) TILE STRIP Q ® Q ® n' AT TOP; H.O. TO SELECT +J Ll/ ® 3Q I' z a u�5 SOT TUB U • — NrV4 II SEE SECTION n 1 - �' - - - \// // // // // / °I I 4 PLANS FOR W \ \\ \\ \\ \\ \\ lu DEPTHS �� UNDISTURBED\\ \ EARTH T I #4 BENT • \ 11 EBAR /\\/\\/\\ \/\\/\ II 11 I6 O.G. r , / // 4 CONC. SLAB V II• . (2) # 4 REBAR X6-IOXIO W.W.M. BETWEEN CENTER 4 UPPER ; OF SLAB II fl , CONTINUOUS SECURED IN PLACE DURING POUR ' EXIST. UNEXGAVATED \\, \\,\\, \\\\\ -�\\\ \\ ��°1� ° I� __ 2" RIGID AREA _ / 3) #4 REBAR / /\/ �u 1 77 . INSULATION /�\/�\/�\/� \ \ \\ ,1 VAPOR BARRIER EXIST. / ',•°- ---a L�===�L 6� COMPACTED 15.1x18 DEEP F. EXIST. GONG. GRADE/\, BASEMENT BEAM (4000 PSI ° ' u.. GRAVEL BASE ISa.a 5F. �' �, z,. 3 STIRRUPS === ====_ X/\\//\1�/�//\/ " o.c. ° ° %\UNDISTURBED \\/ EXIST. 2X8 F.J. 4 REBAR� //� EARTH ® I6" D.G. V.I.F. \ \/ ./ • s /\/ �/ \ (1) #4 REBAR/ // // // /� J \bVER EA FILE�� \j�j \\\ /\ EXIST. ELEC. \/�`\/ EXIST. PANEL ELEC. EXIST. METER C ACCESS OPENING t-- Z W H07 TU5/DF—OfG DF—TA I L a 0 OFOSED FOUNDATION 57RUOTURAL PLAN A-4o1.01 SCALE: 3/4" = I'-O" o a i�fi` Z W 5GALF—V4" = I'-O" o m g ' 0 n. � o Z W m CV Z V) 0 a ao 0 ~ Q U Z d --- "� Q N N z �is) � lil � O -wi Q 0 04 CN m N $ O O m d w MIN. 4" BETWEEN EDGES OF PROJECT: Q m 1-1/2 SQUARE BALUSTER (STYLE TO SELECT) 5IMP501P 0A RAFTER O LT2 T (OR EQUAL) RESIDENCE 5/4"xb" P,1 MOK 5/4"xb" P.T. -- DECK BOARDS P.T. DECK JOISTS AS NOTED ON PLANS - 1600 ALVAHS LANE ,I 5/4" x REG'D I I CUTCHOGUE, NY 11935 HEIGHT P.T. RISER BOLTS 0 EA. POSTED OVERSIZED EXTERIOR SHEATHING AS DECK BOARDS PER PLAN N l WASHERS 4 END NUT PREBORED PER SECTION NOTES — — — — — - INTO BEAM, POST, DECK TIE 4 SIDING MATERIAL AS DRAWING TITLE: P.T. D.J. AS = z RIM BOARD A55EMBELY PER SECTION NOTES P.T.2"x BLOCKING ® EA. I � _ '' u I STRINGER TO MATCH SIZE PT BEAM AS NOTED OF P.T. DECK JOISTS N z I SOLID BLOCK ® 12" O.G. BUILDING PAPER 4 HOUSE WRAP DESIGN DETAILS TO FULLY OVERLAP FLASHING FASTEN STRINGER TO (2) SIMPSON DJT14Z (1) 1/2"(P H.D. 6ALV. THRU EXIST. STUD WALL ! STRUCTURE PLANS DECK JOIST TIE ® BOLT w/OVERSIZED WASHER i BLOCKING (MIN. 6 EA. P05T 4 END NUT PREBORED INTO u Z FLASHING FASTENERS) 5/4 xb' P.T. DECKING POST 4 DECK JOIST TIE N.O.N. ON PLAN/SEGTIOWETAI GAP FOR LS) Nosir� � "51MPSON" ABA44 I DRAINAGE �°) 2"xl2" P.T. STRINGERSC COLUMN BASE PAGE: ® I6" 4"x4" P.T. POST ------- �'-- 4" THK. x 8" WIDE x WIDTH O.G. (MIN. 3 STRINGERS ® OF STAIR P. GONG. PAD 11 EA. STAIRWAY) II GRADE F� '0 'SONOTUBE' FILLED II11 0. 2"xb" P.T. BLOCK IN BETWEEN - -> Ulm 0 MOTE: SOMIDN. 4,000 PSI) �u ° z �, META EA. STRINGER. FASTENED TO ALL DECKING SHALL BE FASTENED P. GONG. PAD w/ Ia/64" x m - L DTT DECK TENSION 3-I/2" CONCRETE SCREWS BY w/ COATED DECKING SCREWS BY t- _ J015TS AS PER PLAN FASTENED w/(2) Z TIE BY 'SIMP5ON' (OR "GALIBURN" (OR EQUAL) - MIN. "DECK MATE" (OR EQUAL i o p 5/8" 0x 5" LONG HEAVY DUTY GAL. FLASHING EQUAL) (5) SORE1^45 PER BLOCK O" MIN. 1 LA6 BOLTS ® 16" O.G. INTO MUD SILL 4 DATE: 01 20 25 6 OF 7 RIM BD.;WHEN ® FOUND. WALL FASTEN COUNTER GRADE GRAD P.T. DECK JOIST w/(2) 5/8"0 x 5" LONG APPROVED° MA50NRY ANCHORS ® 16" O.G. AS PER PLAN -� o ° EXIST. FOUNDATION WALL EX7ER I Oil MOOD STAIR DETAIL EXTER I CR NOOD DEOK DF—TA I L 4 LEDOER OONNEOT I ON DETAIL �'� � �sv� o�,� A-401.01 _ A-401.01 �+air^�� / - SCALE: 3 = A-401.01 _ /4" I'-O" SCALE: I" I'-O" `•�`',�r ., SCALE: 3 4 I -O ¢ � I,. • Insulation 1 i i 1 • Arch itectu DesignBuild g � f !r � 1111 •• F 7. 'A bey . r_ �c � �, ' � - ..,i.-w�..s'•o•"".:rsifa.�"raQ�� ra�.�'?�:1:•+'�_..� z 1 _ 1 1 F. r y y Yi N hhk I 1. • j �s 5 l3`1 a. m� .{ N O m o 1 � CO O Q 7512 i f ; ova A M P Architecture Design + Build r ,n f W Y � k b; 6/18/26,3:07 PM 1000035316.jpg TIM Tol, `i1 >, IN It t Fr, k;. r A } 3 ..N https://mail.google.com/mail/u/0/?ogbl#search/moltz/FMfcgzQgMCbhMkgLMwntTnSMIxNTRfTm?projector=l&messagePartld=0.3 1/1