Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
51791-Z
Y �ovA" soulyo`o Town of Southold * * P.O. Box 1179 ki�kl 53095 Main Rd UN" Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 47285 Date: 08/13/2026 TIHS CERTIFIES that the building Swimming Pool with Fence-In Ground Location of Property: 8255 Bridge Ln Cutchogue, NY 11935 Sec/Block/Lot: 84.4-4.6 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 03/20/2025 Pursuant to which Building Permit No. 51791 and dated: 03/31/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Accessory inground swimming pool fenced to code as applied for. The certificate is issued to: Richard Sachs Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 112563 7/29/2026 PLUMBERS CERTIFICATION: Sol A ho ed Sign ure �o��,oFsouryolo TOWN OF SOUTHOLD BUILDING DEPARTMENT • TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51791 Date: 03/31/2025 Permission is hereby granted to: Richard B Sachs PO BOX 1261 Mattituck, NY 11952 To: Construct an inground swimming pool accessory to a new single-family dwelling as applied for with HPC approval. Pool and pool equipment require a side and rear yard setback of 25 feet. Premises Located at: 8255 Bridge Ln, Cutchogue, NY 11935 SCTM#84.4-4.6 Pursuant to application dated 03/20/2025 and approved by the Building Inspector. To expire on 03/31/2027. Contractors: Required Inspections: Fees: SWIMMING POOLS-IN-GROUND WITH FENCE ENCLOSURE $300.00 CO Swimming Pool $100.00 Total $400.00 Building Inspector NASSAU ELECTRICAL . F OLK IINSPECTORS K 159 Route 25A,Building 1 Suite B Miller Place,NY 11764 ` Telephone:631 495 8136 ? Fax:631 509 4538 ? E-Mail: Info@SuffolkBEI.com16 =. CERTIFICATE OF ELECTRICAL COMPLIANCE Applicant: Wildwood Electric Inc Certificate No.: 112563 Rough In Inspection Date: Sep 11,2025 Final Inspection Date: Apr 21,2026 Application No.: Building Permit No.: 51711 51997 51999 County Tax Map No.: 084.00 01.00 004.006 " This Certificate of Electrical Compliance is limited to the inspection and compliance of electrical equipment and/or work described below,installed on behalf of the applicant named above, located at the premise of and not after the final inspection date above: i Owner: Richard Sachs Site Location: 8255 Bridge Lane,Cutchogue,NY 11935 Owner's Address(if different): a Residential ❑x Indoor ❑x Basement Service Shed Commercial Outdoor Q First Floor "z Pool Hottub �x New Renovation Qx Second Floor 0 Attic/3rd Floor Garage ❑Addition F1 Survey PV Solar 0 Generator Conversion ❑Signs Battery Storage Safety Inspection Other: Pool House INVENTORY Single Phase Heat Gas Duplex Recpt 116 Ceiling Fixture 236 Dual Func Breaker 145 Three Phase Hot Water Gas GFCI Recpt 21 Wall Fixture 28 Smoke Main Panel AC Cond Single Recpt Recessed Fixture CO Detect Sub Panel AC Blower F1__j Range Recpt LED Lighting 153 Smoke CO Combo Transformer Appliance Ckt 12 Dryer Recpt Emergency Time Clock Disconnect Switches 31 Twist Lock Exit Fixtures Pumps GFCI Breaker Heat Pump Electric Heat Pool Luminaire Exhaust Fan 1 Other Equipment:600 amp underground service/1-100 KW generator with 2-ATS Permit 51711(House)Permit 51997(Pool House)Permit 51999(Generator) �' The electrical work and/or equipment described above were inspected and was found to be in compliance with local,... state and national electrical code requirements and this office. r� Applicant: Wildwood Electric Inc License No.: 4836 Date Printed: Jul 29, 2026 Inspected I YN. d. 3 Signature. rt � �o�a0FS0UTyO6 * # TOWN OF SOUTHOLD BUILDING DEPT. cou 631-765-1802 INSPECTION ]- FOUNDATION 1ST/REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I ULA ON/CAULKING [ ] FRAMING /STRAPPING [ FINAL' [ ] FIREPLACE & CHIMNEY [ ] FIRE-SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH)' [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: ''�M�. d✓ DATE INSPECTOR Bunch, Connie From: Dwyer, Tracey Sent: Tuesday, August 11, 2026 5:12 PM To: Bunch, Connie Subject: HPC 8255 Bridge Lane ASIP-Sacks, 8255 Bridge Lane—1000-84.4-4.6 Via photos and emails it has been determined by the HPC members that the subject improvements at 8255 Bridge Lane, Cutchogue, have been completed to their satisfaction . Tracey (Dwyer Building Permits Examiner Town of Southold (631)765-1802 .. l i-_ ;,o�oSUFFatKoG TOWN OF SOUTHOLD—BUILDING DEPARTMENT W T; Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT I f For Office Use Only PERMIT NO. 1 Building Inspector: MA� 2 4 2�25 Applications and forms must be filled out in their entirety.Incomplete p�p���e�t applications will not be accepted. Where the Applicant is not the owner,an StAding UI� Owner's Authorization form(Page 2)shall be completed. -town of so ®Id Date: aj 2 0 2-02•6- OWNER(S)OF PROPERTY: Name: V I C nrA &(ChS SCTM#1000- Project Address: S255 't)rlarAC LGyIC I CUtch UC N3 I Iq 3S Phone#: (0y(0 9 2—TY5ol Email: V 5AGh (&-+hcrbSCc cc'"On •Com Mailing Address: I�0 OX. 120 M ct i-1 CI UGbG - N`f 11952. CONTACT PERSON: Name: `✓C i i G. Lirm Mailing Address:PC box I q (c 0 Shc A Ar-1r-77LS1 Q"A 1`q(O Phone#: (S I - 741q..,2) t 6 Email: bl,n8CV120o 1 S GO DESIGN PROFESSIONAL INFORMATION: Name: �e�E�E' ol-Viror' Mailing Address:�C (off Gre N I (1 Phone#: (.,3(- 26 S - S% p Email: CONTRACTOR INFORMATION: p Name: I 0wrin � in�cr - -bir)6cr f0015 -rnc Mailing Address: c, $Ox_ I C1( 0 S he I �-G{ -1SO A h d , 9 b L 1 Phone#: �031 _ z11 D Email: C�Gyr1�s�Ca bl►'Y�C1r OISeCG DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: E6ther:finSiollc0i m of 0 nc" M' x '-10' ,n Ifc yo®ol $ 12Hi0k0.00 Will the lot be re-graded? 2res [I No Will excess fill be removed from premises? &'es El No 1 f PROPERTY INFORMATION Existing use of property: �Csi&nkia1 Intended use of property: Zone or use district in which premises is situated: Are there any covenants nd restrictions with respect to A ,C this property? Dyes covenants IF YES, PROVIDE A COPY. YCheck Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): j Ol tin VAuthorized Agent ❑Owner Signature of Applicant: Date: 3 j2 0'2 OAS STATE OF NEW YORK) SS: COUNTY OF 5URQ1 ) kI�a— -R-\j ccn being duly sworn,deposes and says that(s)he is the applicant (Name of individual sighing contract)above named, (S)he is the (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this �b*V1 -�&w 0-�- T�w day of N1 are h 2095 Not& Public TRAC:EY L. GWYER PROPERTY OWNER AUTHORIZATION NOTARY PUDLIC,STATE OF NEW YORK NO.01 OW63069GO (Where the applicant is not the owner) QUALTIED IN SUFFOLK COUNTY COMIASSION EXPIRES DUNE 30,2D_* I, Richard Sachs residing at 8255 Bridge Lane, Cutchogue, NY - 11935 Delia Ryan do hereby authorize to apply on my behalf to th r7 thold Building Department for approval as described herein. (0/00i Owner's Signature Date Print Owner's Name 2 SOUTHOLD TOWN HALL-P.O.Box 1179 y, 53095 Main Road-SOUTHOLD,IQEWYORK 11971 Town of Southold CHAPTER 236 o STORMWATER MANAGEMENT REFER FORM. i ( APPLICANT INFORMATION TO BE COMPLETED BY THE APPLICANT ; 'I ONLY FOR PROPERTIES ONE ACRE IN AREA OR LARGER. ) -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - III APPLICANT: (Property Owner, Design Professional, Agent, Contractor, Other) 'I i ' �fl NAME: Vgqji ., �r Date: r (PrinU t Z ' ISEQnalrrrcl •.. r i Contact Information: V NM, AC f (G-Mail&Telephone Number) ! II' I�I I` Property Address / Location of Construction Site: I k-tzqv- ., S.C.T.M. #: 1000 j �,,, ��� ��• District i� Section Block Lot I TO BE COMPLETED BY SOUTHOLD TOWN ENGINEERING DEPARTMENT - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Area of Disturbance is less than 1 Acre. No S.P.D.E.S.Permit is Required I ® - Project does Not Discharge to Waters of the State, No S.P.D.E.S. Permit is Required 1 ® - Area of Disturbance is Greater than 1 Acre &Storm-water Runoff Discharges Directly (I j to Waters of the State of New York. THE APPLICANT MUST OBTAIN a S.P.D.E.S. Permit ) DIRECTLY From N.Y.S. D.E.C. Prior to Issuance of a Building Permit. i 13 - Area of Disturbance is Greater than 1 Acre & Storm-water Runoff Flows Through Southold (I i Town's MS4 Systems to Waters of the State of New York. THE APPLICANT MUST OBTAIN a S.P.D.E.S. Permit through the Southold Town Engineering Department ( Prior to Issuance of a Building Permit. JI ReviewedBy! Date: I I FORM n SMCP-TOS December 2024 v rcl I A David Mammina,Chairperson our u„igve Town Hall Annex Anne Surchin,Vice Chair ���'$ 'S�m� 54375 Route 25 Allan Wexler �myOQ �wo PO Box 1179 Jeri Woodhouse alC Southold,NY 11971 Marina de Conciliiskimf' sou Daryl Ketcham ="�� + ' �� Tel phone:(63d1)65 1809 Kim E.Fuentes,Coordinator -, �..... ... �sEgVATI� W9 d Town;of Southold Historic Preservation Commission Certificate of Appropriateness August 22, 2024 VW�� RESOLUTION No. #05.23.2024.2 Amended RE: ASIP MOUSE, 8255 Bridge Lane, Cutchogue,NY SCTM# 1000-84-1-4.6 Owner: Richard B. Sachs WHEREAS, 8255 Bridge Lane,Cutchogue,NY, is on the Town of Southold Registry of Historic Landmarks; and WHEREAS,as set forth in Section 170-6 of the Town Law(Landmarks Preservation Code)of the Town of Southold, all proposals for material change/alteration must be reviewed and granted a Certificate of Appropriateness by the Southold Town Historic Preservation Commission prior to the issuance of a Building Permit; and WHEREAS,the applicant submitted a proposal on November 30,2023,for approval to demolish an existing dwelling and accessory structures,and to construct a new single-family dwelling,pool house/ cabana and an in-ground swimming pool,including new fencing;and WHEREAS,the applicant's representative,Daniel Butler,Registered Architect, appeared before the Commission for a public hearing on May 23,2024 to describe the proposed demolition of the structures,and the reconstruction of a new single-family dwelling,pool house/cabana and an in-ground swimming pool;and WHEREAS,that the Southold Town Historic Preservation Commission determined that the proposal described as a two-story dwelling with an attached garage and a proposed pool cabana with a swimming in- ground pool and fence enclosure.The improvements will include an asphalt shingle roof,vertical board siding and wood windows manufactured by LePage,all as depicted in the Site Plan and Architectural Plans,sheets A- 0.0,A-0.1,A-0.2,A-1.2,A-2.0,A-2.1,last revised on May 20,2024(received May 22,2024);and Sheets A- l. 0 and A- 1. 1, last revised April 18,2024,(received April 19, 2024,one window per bedroom located on the, second story of both side elevations as casement double hung style with offset glass for top and bottom lites,to satisfy egress opening size requirements and conform to the New York State' s Building code means of egress) prepared by Daniel A. Butler, R.A.,meets the criteria for approval under Section 170- 8 (A)of the Southold Town Code;and WHEREAS,the applicant shall submit to the Commissioners photographs of the finished improvements upon completion;and Certificate of Appropriateness 405.23.2024.2 AMENDED HPC,ASIP HOUSE,Richard B.Sachs, SCTM No 1000-84-1-4.6 WHEREAS,the Commissioners may conduct a site inspection of subject premises once improvements are completed; and WHEREAS,on August 22,2024,the applicant's representative,Daniel Butler, Registered Architect,appeared before the Commission for a Work Session to describe Amendments to the above referenced reconstruction of a new single-family dwelling,pool house/cabana and an in-ground swimming pool;and WHEREAS,the Commission has the authority to determine that some proposals do not rise to the level of requiring a public hearing,as the proposal is de minimis in nature;and the Commission has determined that the subject application is de minimis in nature,the Amended design does not require a Public Hearing, and therefore,a Certificate of Appropriateness may issue; and NOW,THEREFORE,BE IT RESOLVED,that the Southold Town Historic Preservation Commission determines that the AMENDED proposal described as a two-story dwelling with an attached garage and a proposed pool cabana with a swimming in-ground pool and fence enclosure.all as depicted in the Site Plan and Architectural Plans,sheets A-0.0,A-1.0,A-1.1,A-2.2,A-2.3,A-2.5 and A-2.6, last revised July 28,2024, (received July 24,2024)prepared by Daniel A. Butler, R,A.,meets the criteria for approval under Section 170- 8 (A)of the Southold Town Code; and BE IT FURTHER RESOLVED,that the Commission approves the request for an AMENDED Certificate of Appropriateness,subject to approvals by all involved agencies;and BE IT FURTHER RESOLVED,that any deviation from the approved plans referenced above may require further review from the commission. Motion made by Commissioner Mammina Motion seconded by: Commissioner Woodhouse VOTES:AYES:Commissioners Mammina, Surchin,Wexler,Woodhouse,de Conciliis and Ketcham(6-0) RESULT:Passed Please note that any deviation from the approved plans referenced above may require further review from the commission. Signed: QUJI—_4 Kim E.Fuentes,Coordinator for the Historic Preservation Commission Date: September 3,2024 s ' out Un14u Anne Surchin,Vice Chair `,��9 e'ye^. 54375 Main Road,NYS Route 25 Allan Wexler `@°0 '' �a�, PO Box 1179 Marina de Conciliis a � '"�° Southold,NY 11971 Jeri Woodhouse ° Telephone:(631)765-1809 David Mammina �, %tu kimf@southoldtownny.gov Daryl Ketcham Kim E.Fuentes,Coordinator �'FSERVATION Town of Southold Historic Preservation Commis . MAY 3 1 2024 V Certificate of Appropriateness May 23, 2024 Buttding Town of RESOLUTION #05.23.2024.2 RE: 8255 Bridge Lane, Cutchogue,NY. SCTM#1000-84-1-4.6 Owner: Richard B. Sachs,ASIP HOUSE RESOLUTION: WHEREAS, 8255 Bridge Lane, Cutchogue,NY, is on the Town of Southold Registry of Historic Landmarks; and WHEREAS, as set forth in Section 170-6 of the Town Law(Landmarks Preservation Code)of the Town of Southold, all proposals for material change/alteration must be reviewed and granted a Certificate of Appropriateness by the Southold Town Historic Preservation Commission prior to the issuance of a Building Permit; and WHEREAS, the applicant submitted a proposal on November 30, 2023, for approval to demolish an existing dwelling and accessory structures, and to construct a new single family dwelling, pool house/cabana and an in-ground swimming pool, including new fencing; and WHEREAS, the applicant's representative, Daniel Butler, Registered Architect, appeared before the Commission for a public hearing on May 23, 2024 to describe the proposed demolition of the structures, and the reconstruction of a new single family dwelling,pool house/cabana and an in-ground swimming pool; and WHEREAS,the proposed improvements are described as a two-story dwelling with an attached garage and a proposed pool cabana with a swimming in-ground pool and fence enclosure. The improvements will include an asphalt shingle roof,vertical board siding and wood windows manufactured by LePage, all as depicted in the Site Plan and Architectural Plans, sheets A- 0.0, A-0.1, A-0.2, A-1.2, A-2.0, A-2.1, last revised on May 20, 2024 (received May 22, 2024); and Sheets A-1.0 and A-1.1, last revised April 18, 2024, (received April 19, 2024, one window per bedroom located on the second story of both side elevations as casement double hung style with offset glass for top and bottom lites, to satisfy egress opening size requirements and conform to the New York State's Building code means of egress)prepared by Daniel A. Butler,R.A.; and 1 „ our Uni94e ti David Mammina, Chairperson A'.n aAnne Surchin, Vice Chair myTdx ' 54375 Main Road,NYS Route 25 Allan Wexler Q r PO Box 1179 SOUTHOLD Marina de Conciliis • Umm Southold NY 11971 Jeri Woodhouse N �aurdoa -�^ o Telephone: (631)765-1809 Daryl Ketcham o9� � Email: kimf@southoldtownny.gov Ahmad Sardar-Afkhami A a� Kim E.Fuentes,Coordinator RFSfRVAT1ON Town of Southold Historic Preservation Commissio r" JUN - 4 2025 L. Certificate of Appropriateness May 22, 2025 i3uFll�ani.:, � ,pnt RESOLUTION #05.22.2025.1 and Amendment to #05.23.2024.2 RE: 8255 Bridge Lane, Cutchogue, NY. SCTM# 1000-84-1-4.6 Owner: Richard B. Sachs,ASIP HOUSE RESOLUTION: WHEREAS, 8255 Bridge Lane, Cutchogue,NY, is on the Town of Southold Registry of Historic Landmarks; and WHEREAS, as set forth in Section 170-6 of the Town Law(Landmarks Preservation Code)of the Town of Southold, all proposals for material change/alteration must be reviewed and granted a Certificate of Appropriateness by the Southold Town Historic Preservation Commission prior to the issuance of a Building Permit; and WHEREAS, the applicant submitted a proposal on May 13, 2025, for an approval to install a privacy fence surrounding a new HVAC Condensers and an Emergency Generator located in the side yard; and WHEREAS, the applicant also requested an Amendment of Certificate .of Appropriateness #05.23.2024.2 to redesign a pool house/cabana and an in-ground swimming pool, both located in the rear yard, and surrounded by a code conforming fence previously approved by the Commission on May 23, 2024; and WHEREAS, the applicant's representative, Daniel Butler, Registered Architect, appeared before the Commission at a Work Session on May 22, 2025 to describe the proposed privacy fence surrounding the HVAC Condensers and Emergency Generator and the proposed changes to the pool house/cabana and the in-ground swimming pool; and WHEREAS,the Commission recommends that the height of the privacy fence be four feet in height; and WHEREAS, the proposed improvements are depicted in the Site Plan and Architectural Plans, Sheets A- 0.0, A-2.5, A-2.6, last revised May 14, 2025, and A-0.3, dated May 15, 2025, all prepared by Daniel Butler, Registered Architect; and � 6t Certificate of Appropriateness,Res.#05.22.2025.1 HPC, Sachs,ASIP House, 8255 Bridge Lane, SCTM No. 1000-84-1-4.6 Page 2 WHEREAS, the Commission has determined that pursuant to Chapter 170-4(E)(2) of the Southold Town Code, the Commission has the authority to determine that some proposals do not rise to the level of requiring a public hearing, as the proposal is de minimis in nature; and WHEREAS, the Commission has determined that the subject application for the Certificate of Appropriateness is de minimis in nature and therefore does not require a Public Hearing; and WHEREAS,the applicant shall submit to the Commissioners photographs of the finished improvements upon completion; and WHEREAS,the Commissioners may conduct a site inspection of subject premises once improvements are completed; and NOW THEREFORE BE IT RESOLVED, that the Southold Town Historic Preservation Commission determines that the privacy fence surrounding a new HVAC Condensers and an Emergency Generator, located in the side yard; and the Amendment of Certificate of Appropriateness #05.23.2024.2 to redesign a pool house/cabana and an in-ground swimming pool, both located in the rear yard,and surrounded by a fence,previously approved by the Commission on May 23, 2024, meets the criteria for approval under Section 170-8 (A) of the Southold Town Code; and BE IT FURTHER RESOLVED, that the Commission approves the request for a Certificate of Appropriateness, subject to approvals by all involved agencies; and BE IT FURTHER RESOLVED, that any deviation from the approved plans referenced above may require further review from the Commission. Motion made by: Commissioner Mammina Motion seconded by: Commissioner de Conciliis VOTES: AYES: Commissioners Mammina, Wexler, Woodhouse, de Conciliis, and Ketcham, Sardar- Afkhami (6-0) RESULT: Passed Please note that any deviation from the approved plans as referenced may require further review from the commission. Signed: Dated May 28, 2025 Kim E. Fuentes Coordinator for the Historic Preservation Commission i = a www.dignetnycli.com u a 1 NSW Y'OFK CIS' °r EXIST, cP To BE PROPOSED EMERGENCY GENERATOR ON CONC SLAB ZON I NCB a z www.call811.com , . o lot &LO�� IMP (for other states) / ABANDONED PER µ yq \ SCDHS REGS, BULK SCHEDULE FOR RESIDENTIAL DISTRICTS W z 800-272-4480 1 81 / / PROPOSED 1,000 GALLON IN o / GROUND PROPANE 'TANK FOR a- z O PP DISTRICT A-C i x EMERGENCY GENERATOR z Q 62,1 o Q By law,excavators and contractors working in For safety reasons, homeowners are strongly �'P�Q LL a the five boroughs of New York City and Nassau encouraged to call as well when planning any / MIN, REQUIREMENTS FOR 1-FAMILY DETACHED �`� `� and Suffolk Counties on Lon Island must type of digging on their roe Homeowners EXIST, G o 0 9 YP 99 9 property.dY• � � ` EXIST, O.W. SERVICE BE ABANDONED. DWELLINGS contact Di Net, 1-800-272-4480 or 811, at least can contact us direct) at 1-800-272-4480 or b O WELL 9 y Y z ° 48 hours but no more than 1 / MOVE TO NEW UNDERGROUND SERVICE working days calling 811,the national call before you dig O (excluding weekends and legal holidays)prior to number. For excavation work completed on -C / LOT SIZE (SQUARE FEET) 80 000 ( 9 9' Y )P V / ti O /ter v 'y uall beginning any mechanized digging or excavation personal property, it is the contractor's / {�¢ �� ��; O \i �j, PROPOSED 6 BEDROOM LOT WIDTH (FEET) 175 work to ensure underground lines are marked. responsibility--NOT the homeowner's--to contact YY / �` ¢0 ' Of/ 0 / 1S SANITARY SYSTEM Excavators and contractors can also submit DigNet. Having utility lines marked prior to 0 / kQ �Q �� �o p LOT DEPTH (FEET) 250 locate requests online,through ITIC. If you do digging is free of charge. �,1 ,`�G / CP I , SITE Q not currently use[TIC,please call ti� Q¢�49 � �i NOTE: FOR SANITARY AND STORM DRAINAGE FRONT YARD (FEET) 60 o d 1-800-524-7603 for more information. / yp 41 ♦� 4' TALL PRIVACY Y\ \ DESICxN SEE &WEET SPI42 OF THE APPROVED LOCATION � 4' FENCE 4 GATE TO / PRIMARY FRONT YARD (FEET) 60 © _ � CODE, SEE BHT, ' � S.G,D,N,S S1TE PLAN, S,C,D.N,S, REFERENCE SECONDARY FRONT YARD (FEET) 40 ° N BY: McDONALD GEOSC:IENCE PROPOSED CONTROL PANEL AND BLOWER: A-0.3 FOR DETAIL NO,: R-24-0943. DATED 11/6/2024. Ut % �� i�\ ' SIDE YARD (FEET) 20 N DATED: 3/4/2024 SEE 'CONTROL PANEL REQUIREMENTS' NOTES, 11�,, \ (so / \ w THIS DWG, FOR MOUNTING DESIGN AND EXIBOTH SIDE YARDS (FEET) 45 N' N EL. 62,5' GRADE 0,0' REQUIREMENTS CP ^ ' �� �,'� _ \ EXIST. 2 STORY FRAME DWELLING REAR YARD (FEET) 15 z 12 o a- `� / ��' / TO BE DEMOLISHED o SEE PROPOSED H FRAME DETAIL, ON DWG SP2 0 EL, 61,5' DARK BROWN LOAM OL / / '>L,? \ LIVABLE FLOOR AREA (SQUARE FEET PER DWELLING UNIT) 850 ° o a o 0 OF THE APPROVED HEALTH DEPARTMENT SET, E > w a 1 BELOW GRADE / S (1)8' DIA.x / �- \ a a r PROPOSED AC CONDENSING UNITS �\�f � \ A MAX. PERMITTED DIMENSIONS 4 ON CONC. SLAB. / EL, 58,5' / +p cA� / tt� ;, \ C NO WELL 4 SANITARY LOT COVERAGE (PERCENT) 20 BROWN SILT ML EXIST, FR SHED 03 / 4, AREA WAY ��fiaA'\,''Jf \` \ ?� SYSTEMS WITHIN 150 FT, BUILDING HEIGHT (FEET) 5,6 35/25 4' BELOW GRADE OR- WATERS WITHIN 300 FT, TO BE DEMOLISHED , \ �Pti %\ \\ \ a NO SURFACE AGE NUMBER OF STORIES 2-1/2 � \0� EXIST. FIR SHED 02 TO �`�, �j01�)�ltl ��Cz l\ �(v 8'DIA,x ` NOTES: LOCATION MAP BE DEMOLISHED// \ / ?3 � � 11�T1 �t� G� \ 6'E.D.SD \ 1, SEE TEXT OF CHAPTER AND DENSITY AND MIN, LOT SIZE SCHEDULES FOR 2 N,T,S, k ¢ 4, / e \ J APPLICABLE DISTRICTS, BROWN FINE SAND SfP �� �4 4� Gp / n)8'DIA.x I _ ✓ c \ \ \ \ � 6'E.D.5D � ♦ ��, �e- TE T 4, SEE LIMITS TO GROSS FLOOR AREA (GFA) IN 280-4, EL 45 5' 11 BELOW GRADE •��? 0 `,l �,\ \ / / N Goy \ y 5, BUILDING HEIGHT FOR ALL DISTRICTS: 35 FEET TO PEAK OF SLOPING NO GROUNDWATER ENCOUNTERED � EL. 45,5' I c� ��y� \� \ 6�5E 2.9 \ ROOFS, 25 FEET FOR FLAT OR MANSARD ROOFS, SEE DEFINITIONS, S� DATA: ��; PRO-PO SEPTLC S 61EM- \ 6, ROOFS MUST BE WITHIN THE SKY PLANE, SEE DEFINITIONS. DA HIGHEST EXPECTED GROUND WATER 9 EIL, 11.26' PE FOR-POOL-HOUSE: / � ,�o9 �� G� �� � \ SITUATE AT: WELL MONITOR STATION 553324,1 1-1000 GAL SEPTIC TANK/ GR,�y�EL (u 8'DIA. x , 0255 BRIDGE LANE 1-5' DIA, X 12' E.D. LEAAING R � ` �9�� �'�' DRIVE ,I- ; `, 8'E.D.5D / CUTCHOGUE, NY 11935 TEST IOLE POOL `� rti COUNTY OF SUFFOLK r �s Frye cE �� 0 '��� \ /� 'L // TOWN OF SOUTHOLD N,T,S, / / .0, \ o� 0' �� O �� - 150' FROM EXIST, SCTM ": 1000-084-01-004.6 �ox, _ i 8�E DDI Dx �� \ \ O ��' / ADJACENT WELL ZONING DISTRICT: A-C / ti Rio ¢ EXISTING WELL TO �p ¢ // m \ 0'Al \ / APP_LICANT-J OWNER: s / $ 00 l BE ABANDONED �¢ \ / _ _ _ _ RICHARD B, SACHS = �d - - - - ���`�,� -o (1)4'DIA.x 4' 4'x8' CONC. SLAB FOR \ \ / - - STEWART TITLE INSURANCE CO, W C14 \ c L E.D.5D / r1 GARBAGE BIN o \ ` I F'r-i - $ITE_.DATA w AREA OF SITE. 4,3108 ACRES 6ET5ACKS: w <C J„ S PRINCIPAL BUILDING OR STRUCTURE, MIN, YARDS (FEET): � X Z U_ I REQUIRED: EXISTING PROPOSED: O I FRONT = (00,0' 43.5' 63,5'I 1n0`)) POOL FENCE - EXIST. FRAME SHED 01 � / x SIDE = 20,0 / 45.0 80,1 45,0 � � 3: 0 TO CODE TO BE DEMOLISHED / I (0 S REAR = 75,0' 307,5' �15,0' 111 f� / / / PROPOSED 11,5'x20' \ \ / \ 1 '� HEIGHT= 35' / 2 STORY 2 STORY 2 STORY (28'-0") / POOL CABANA W/ \ // X o� ?? O 3: C14 COVERED PORCH - \ \ 62.6 ° ACCESSORY BUILDING OR STRUCTURE, MIN, YARDS (FEET): tD - / (SLAB ON GRADE) / // / \ REQUIRED: EXISTING PROPOSED: (3)8'DIA.x 6'E.D.5D ' _ O \ SIDE = 25,0 52,5 65,2 R ��O II / \ REAR = 25,0' 211,9' >25' \ / / / MAXIMUM ALLOWABLE HEIGHT FOR ACCESSORY STRUCTURE FOR A LOT � ���, 80,000 s,F OR OVER IS 22' MAXIMUM WEIGHT Fr@S@I'Vdt1On CommisslOn / PROPOSED 'L / \ R ACHITECT: NEW WELL, � I / SURVEYED BY: / ,�'� / n^ SMITH, JUNG 4 GILLIS ' xl ' I / / I / VV \\ PROFESSIONAL LAND SURVEYOR Dated: �S , / I / I / \ 120 MEDFORD AVENUE J✓'7C� p'. 1 / , rn" \ PATCHOGUE, NY 11172 �� �P ; ' -, /` W \ Q 631-415-3192 PG , \ o WELL AUGUST 11, 2022 150' FROM EXIST, \ \y ?6 AREA CALCULATIONS FS toe ID MMISSION ��� OF ADJACENT WELL TOWN- OOTHOL / I HISTORIC PRESERVATION CO DANIEL A. BUTLER, R.A. I EXISTING PROPOSED ca MAIN HOUSE (] 10 `o \ \ / /' \ FIRST FLOOR 1026 2929 Q SECOND FLOOR 180 1462 0 \ / FLOOR AREA TOTAL 1806 5004 COVERED PORCH 218 630 ('(1 Q `�./ REAR DECK / PORCH 199 168 Q� z W 0 GARAGE 616 O LLl L O O Z � �� G FRAME SHED "1 246 O Z, Z Z p Of \ / ,� ♦� FRAME SHED "2 320 I Q U 4 \x 61,3 \ �/ ' 0 � �{`'�y FRAME SHED 03 IIS ►--� WQ W :3 POOL HOUSE 350 wwpO p N y,4-4 � POOL HOUSE PORCH 150 LL c0 } O Q NO �, 0,< ��` POOL 800 QO - ut * L n O OH TOTAL 2181 2586 5,103 ♦ O p- N N t j Q GROSS FLOOR ,AREA CALCULATIONS Z ACRE SIZE 43,560 SY, O .. TOTAL LOT SIZE 4.3108 ACRES Z \ / 111 \ 181,118,448 S.F. - 80,000 101,118, 448 S,F, O ~ J / 280-201 2,5% 9 \� (F) UP TO 2,5 LOT AREA IN 1,100 S,F, x �V(�J♦ \ \\ 200,000 S.F. 00,000EXCESS OF, ♦ PAGE S 2,694,4612 S.F. 2,6g4,4612 S.F. ' % SITE � LAN 1 \ //\ ,n ALLOWABLE GFA 9194.4612 S,F, ENTIRE LOT 1 I" = 30'-0" 00 �i �--i a '� G�, En 100, 70 F 5COFE OF......wo A� 0 ,00 1P 15 10 0 30 - 610 120 _I GRAPHIC SCALE I" = 30'-0" \ / Co �G 1, DEMOLITION OF EXISTING DILAPIDATED DWELLING AND ACCESSORY STRUCTURES ♦ N 2, PROPOSED NEW DWELLING IN GROUND SWIMMING POOL AND DETACHED ACCESSORY, N 3, RELATED UTILITY WORK INCLUDING: NEW SANITARY SYSTEM, WATER, ELECTRIC AND GAS, to LO THESE DRAWINGS AND ACCOMPANYING SPECIFICATIONS,PAS INSTRUMENTS OF SERVICE,ARE THE EXCLUSIVE PROPERTY OF THE ARCHITECT AND THEIR USE AND PUBLICATION SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED.REUSE,REPRODUCTION OR PUBLICATION BY ANY METHOD,IN WHOILE OR IN PART,IS PROHIBITED EXCEPT BY WRITTEN PERMISSION FROM THE ARCHITECT.TITLE TO THESE PLANS SHALL REMAIN WITH THE ARCHITECT.VISUAL CONTACT WITH THEM SHALL CONSTITUTE PRIMA FACIE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. our Unr94e David Mammina,Chairperson `,��0 A/ Anne Surchin,Vice Chair � , �w 54375 Main Road,NYS Route 25 Loll Allan Wexler Q` "� f rsm PO Box 1179 SOU�THOLD Southold NY 11971 Marina de Conciliis r, Jeri Woodhouse FOisao *' o Telephone: (631)765-1809 Daryl Ketcham o9�c �' Email:kimf@southoldtownny.gov Ahmad Sardar-Afkhami A oo Kim E. Fuentes,Coordinator 9FSFAVAM Town of Southold Historic Preservation Commission r JAN 2 3 2026 - Certificate of Appropriateness January 15, 2026 RESOLUTION #01.15.2026.1 RE: 8255 Bridge Lane, Cutchogue;NY. SCTM# 1000-84-1-4.6 Owner: Richard B. Sachs,ASIP HOUSE RESOLUTION: WHEREAS, 8255 Bridge Lane, Cutchogue,NY, is on the Town of Southold Registry of Historic Landmarks; and WHEREAS, as set forth in Section 170-6 of the Town Law(Landmarks Preservation Code)of the Town of Southold, all proposals for material change/alteration must be reviewed and granted a Certificate of Appropriateness by the Southold Town Historic Preservation Commission prior to the issuance of a Building Permit; and WHEREAS, the applicant submitted a proposal on October 29, 2026, for an approval to construct a sauna and install fencing and an entry gate surrounding an in-ground swimming pool located in the rear yard; and WHEREAS, the applicant's representative, Daniel Butler, Registered Architect, appeared before the Commission at a Public Hearing January 15, 2026 to describe the proposed improvements; and WHEREAS, the proposed improvements are depicted in the Site Plan and Architectural Plans, Sheets A- 0.0, A-2.7, last revised October 25, 2025, and A-0.4, dated October 28, 2025, all prepared by Daniel Butler, Registered Architect; and WHEREAS, the applicant shall submit to the Commissioners photographs of the finished improvements upon completion; and WHEREAS, the Commissioners may conduct a site inspection of subject premises once improvements are completed; and Certificate of Appropriateness,Res.#01.15.2026.1 HPC, Sachs,ASIP House, 8255 Bridge Lane,SCTM No. 1000-84-1-4.6 Page 2 NOW THEREFORE BE IT RESOLVED, that the Southold Town Historic Preservation Commission determines that the proposed improvements for a sauna, fencing and entry gate as depicted in the Site Plan and Architectural Plans, Sheets A-0.0,A-2.7, last revised October 25, 2025, and A-0.4, dated October 28, 2025, all prepared by Daniel Butler, Registered Architect; meets the criteria for approval under Section 170-8 (A) of the Southold Town Code; and BE IT FURTHER RESOLVED,that the Commission approves the request for a Certificate of Appropriateness, subject to approvals by all involved agencies; and BE IT FURTHER RESOLVED, that any deviation from the approved plans referenced above may require further review from the Commission. Motion made by: Commissioner Mammina Motion seconded by: Commissioner de Conciliis VOTES: AYES: Commissioners Mammina, Surchin, Wexler, de Conciliis, and Sardar-Afkhami (5-0) (Members Ketcham and Woodhouse Absent) RESULT: Passed Please note that any deviation from the approved plans as referenced may require further review from the com fission. L Signed: Dated,January 21,2026 Kim E. Fuentes Coordinator for the Historic Preservation Commission M' U cn O Histerle Prasaniation Commission a Resoiutio #: 15.o cla 6. a Dat-ed: WrnX to Q 0 z '� L7q d in � a m Gam] 3 o w. s w P. �N ' Ix6 HORIZONTAL CEDAR FENCE RAILS AND CAP DA I A. 6� 1(�}•f BLACK TURKEY WIRE FENCE W/ I" SPACE F� OF 4 Ix6 VERTICAL AND _ CROSS RAILS T- *0 m 6X6 CEDAR POST z "� LL W/ CAP M tr A u 73 o° o m o' (2) MOTORIZED LU Q v o a a SWING GATE TO CODE. W o emu , Ln LU to o POURED O 13 m cq CONCRETE FENCE ,"� o- Q N N o FOOTING TO FROST W '0 o In DEPTH (3'-0" MIN.) ' it - oil �' _ O" (SIZE BY GATE A o JII DESIGNER) z La J Ul Q O p FRONT ELEVATION SECTION A PAGE: DRIVEWAY CODE COMPLIANT FENCE AND GATE ��DRIV�WAY FENCE DETAIL A — O . 4 MATERIAL LEGEND: y " ASPHALT SHINGLE ROOF } COLOR: BLACK Hgtaft Pmervation Commission Resolutloh lf: Dated:MUM _._...►_� ►s' I ollo A BLUE STONE GRAVEL � X � LL -- O Z -- LEPAGE WOOD WINDOWSM if _- COLOR: BLACK ° ? 0 FOUNDATION - PARGED * ' ? w NIM-A. TRIM BOARDS COLOR: BLACK � o m � W W o o m > 3 R HEMLOCK BOARD AND a ° o c a� + BATTEN SIDING BRICK # BRICK VENEER a v q COLOR: WEATHERED _ FOR CHIMNEY: d w z op ( o ABBEY BROWN' _o 0 z ai R � PAGE: M ' 5" OGEE GUTTER COLOR: BLACK WOOD FENCING � • � • 1 www.dignetnycli.com or Of�Z'W YOR, ff www.ca11181l.com EXIST. CP TO BE u a (for other states) \\ ABANDONED PER PROPOSED EMERGENCY GENERATOR CQN CONC, SLAB, ZONING 0 z � o SCDHS BEGSF . BULK SCHEDULE FOR RESIDENTIAL DISTRICTS Z 800"272"��80 8 I i / PROPOSED 1,000 GAILLON IN0 GROUND PROPANE TANK FOR / " EMERGENCY GENERA1OR DISTRICT A-C By law, excavators and contractors working in IFor safety reasons, homeowners are strongly 62.1 (L z the five boroughs of New York City and Nassau encouraged to call as well when planning any , Z a Z and Suffolk Counties on Long Island must type of digging on their property. Homeowners EXIST, MIN. REQUIREMENTS FOR I-FAMILY DETACHED ���� 13 a IF contact DigNet, 1-800-272-4480 or 811,at least c;an contact us directly at 1-800-272-4480 or by Z WELL EXIST, O,H, SERVICE BE ABANDONED, DWELLINGS I G�`� o A p O / ��� w Q Q 48 hours but no more than 10 working days calling 811,the national call before you dig O MOVE TO-NEW UtNDERGROUND SERVICE w (excluding weekends and legal holidays)prior to number. For excavation work completed on -C / � � LOT SIZE (SQUARE FEET) 80,000 d u beginning any mechanized digging or excavation personal property, it is the contractor's �/� / ��O�ti�ti /S u Q work to ensure underground lines are marked. responsibility--NOT the homeowner's--to contact Y � �„ Q j�� �'�• PROPOSED 6 BEDROOM LOT WIDTH (FEET) 1�5 0 Excavators and contractors can also submit DigNet. Having utility lines marked prior to / A Q¢'�� v �� ?$ SANITARY' SYSTEM -{� 9 a locate requests online, through ITIC. If you do digging is free of charge. \44 \�� \G / LOT DEPTH (FEET) 250 B not currently use(TIC, please call ¢ 2� y° CP `� f� I NOTE: FOR SANIITARY AND STORM DRAINAGE FRONT YARD (FEET) 60 SITE m 1-800-524-7603 for more information. / Y�4�4 � 6� TALL PRIVACY ir Q � FENCE 4 GATE TO DESIGN SEE SHEET SPl42 OF THE APPROVED PRIMARY FRONT YARD (FEET) LOCATION S a !� S,C,D,H,S SITE PLAN, S,C,D,H,S, REFERENCE 60 CODE, SEE SHT, ® w BY: McpONALD GEOSCIENCE PROPOSED CONTROL PANEL AND BLOWER: A-0,3 FOR DETAIL �'� NO,: R-24-09 SECONDARY FRONT YARD (FEET) am43, DATED 11/6/2024, 40 o z u d DATED: 3/4/2024 SEE 'CONTROL PANEL REQUIREMENTS' NOTES, 20 0 i6 ',°' � ��/ SIDE YARD (FEET) THIS DWG, FOR MOUNTING DESIGN AND EXIST, ? (' coo UJI 8 BOTH SIDE YARDS (FEET) 45 o \ \ o EL. 62.5' GRADE O.O' REQUIREMENTS CP � i � EXISIT, 2 STORY FRAME DWELLING SEE PROPOSED H FRAME DETAIL, ON DWG SP2 0 ^\ REAR YARD (FEET) 15 a a a EL. 61,5DARKBROWN LOAM CaL / \ � , � ,>L�,\ � TO BDE DEMOLISHED OF THE APPROVED HEALTH DEPARTMENT SET, - LIVABLE FLOOR AREA (SQUARE FEET PER DWELLING UNIT) 850 0 4 o° n o 1 BELOW GRADE D E o tQ PROPOSED AC CONDENSING UNITS / ti� /�� 6' E.D.SD 'Q, \ �T3----1 LP, 4 � � Q / - ` MAX, PERMITTED DIMENSIONS d _, o EL, 58,5' ON CONC. SLAB, °yti° / / ,- / OR / EP c�� \ / _ o NO WELL E SANITARY ° Pt ' SYSTEMS WITHIN 150 FT, LOT COVERAGE (PERCENT) 20 BROWN SILT A EXIST, FIR SHED "3 -� R <, AREA WAY `��'�A ' ��\ �� `_ `� NO SURFACE ACE s,6 4 BELOW GRADE / / a WATERS WITHIN 300 FT, BUILDING HEIGHT (FEET) 35/25 t0 BE DEMOLISHED � � ,p � \ \ EXIST, FIR SHED #2 TO �S oy _ \� \ NUMBER OF STORIES 2-1/2 �. � B EMOLISHED $ o t'"' \ �/tv e'DIA. x '�',\ NOTES: LOCATION O� J� �I E.D.ED �4 L A ON MAP PROPOSED I, SEE TEXT OF CHAPTER AND DENSITY AND MIN, LOT SIZE SCHEDULES FOR 2 BROWN FINE SAND SP i c R¢ \ tic�� DRIVEWAY APPLICABLE DISTRICTS, N,T,S, PROPOSED 12 x12 SAUNA cu e'DiA. x I1 BELOW GRADE / = o� \ EL, 45,5 (DRY BLDG,) \ \ E-D. 5D > �� Cy 01 \ �/ \ \ TEST LATE 4. SEE LIMITS TO GROSS FLOOR AREA (GFA) IN 280-4, _ L - _ -` Ab G \ HOLE L' 5. BUILDING HEIGHT FOR ALL DISTRICTS: 35 FEET TO PEAK OF SLOPING A 5 , NO GROUNDWATER ENCOUNTERED m EL. 45„5' �~�-~ _ / \ °ti �p� \ 62,5 2,9 ROOFS, 25 FEET FOR FLAT OR MANSARD ROOFS, SEE DEFINITIONS,HIGHEST EXPECTED GROUND WATER EL, 111,26 PER O S W IC S ST 36 i o \� � \ (b. ctt, ROOFS MUST BE WITHIN THE SKY PLANE, SEE DEFINITIONS, S 1 1 P DATA: Historic Preservation Commission WELL MONITOR STATION 553324,1 FOR POOL HOUSE: / �o° G.p �� 1-1000 GAL SEPTIC TANK i q`-F� GR \ SITUATE AT: Resolution #: C2 1 . 5.D_Zk) 18� �� 1-8 DIA, X 12 E,D, LEA NG Grp R �q<� �'�' DRI Y CUTCHOGU Dated: _ J 8255 BRIDGE LANE LE POOL / i \ \ - � ' A / E, NY IIS35 16: \ \ry° / PG O TOWN OF SCOUNTY F SUFFOLK N,T,S, / 'o✓ o, lU 8' MA.x / 'S'ti `� s' DiA• x \ 0' r7 �� �' / OUTHOLD y 8' E.D.5D t0 150 FROM EXIST, SCTM •: 1000-084-01-004,6 ¢ OS --__ s'E.D. ED 0�\0� \ / 8�ti ��\�� EXISTING WELL TO \ \ �¢ a / ADJACENT WELL ZONING DISTRICT: A-C G\4. �(�p\�`?' }�' �d / s. �tio / `��' BE ABANDONED 0�' / csl COO Oe 4��> / ` � k¢ / APPLICANT / OWNERS O p� i �\ L o �� (U 4' DIA,x 4' 4 x8 CONC, SLAB FOR �� / - - - - - - - - - - - - - RICHARD B, SACHS 01< G o E.D.ED GARBAGE BIN \ / STEWART TITLE INSURANCE CO, IZ SITE DATA: �4¢ \ I AREA OF SITE: 4,3108 ACRES F-z-1 SETBACKS: W X PRINCIPAL BUILDING OR STRUCTURE, MIN. YARDS (FEET): Z Xwu- 'G0� 4 / \ \> EXIST, FRAME SHED1 \ / \ I FRONT = 60 OIL. EX5TING PROPOSED: O 5 SIDE = 20,0' / 45,0' 80,1' 45,0' PROPOSED I1,5x20 \\ ,'� Y �.`_.� POOL EQUIP. TO BE DEMOLISHED \ // \ I k 61,9 REAR = 15,0' � O � � • l.11 0 yw i U/G PROPANE \ I o HEIGHT= 35' / 2 STORY 2 STORY 2 STORI" (28'-O") Q- f 06 o POOL CABANA W/ \ , / 381,5 m"O COVERED PORCH POOL FENCE TANK \ / 1 (SLAB ON GRADE) TO CODE \ / 1x o �-1 : O \ / \ 62.6 ACCESSORY BUILDING OR STRUCTURE, MIN, YARDS (FEET): / R �5O' - 0" i' I (3)e'DIA,x 6'E.D. SD \ / REQUIRED: EXISTING PROPOSED: SIDE = 25,0' 52,5' 65,2 REAR = 25,0' 211,9' >25' lU ; / MAXIMUM ALLOWABLE HEIGHT FOR ACCESSORY STRUCTURE FOR �A LOT w ~ j PROPOSED \ 4 ; /i \ ti 5 NEW WELL, �\ I ,� \ 60,000 S,F OR OVER IS 22' MAXIMUM HEIGHT X , �� \ j / \\ SURVEYED BY: D ARCHITECT- ` SMITH, JUNG t GILLIS I V \ PROFESSIONAL LAND SURVEYOR !' C' 120 MEDFORD AVENUE OPT z�}25 / '00 !, \\ PATCHOGUE, NY 11T12 yip TOWN "` r ' M \ 631-415-3192 'TORIC PRES RVA�WTyp�D ;I p ,�4) \ � �� \ / / o WELL AUGUST 11, 2022 N COMnfisS10 ' 150' FROM EXIST, ' AREA CALCULATIONS:IONS: ¢ / / Cr ♦ I ADJACENT WELL LOT' COVERAGE OR EXISTING PROPOSED / TRIBUTARY I - MAIN HOUSE DANIEL A. BUTLER, R.A. FIRST FLOOR 1026 Y (SAUNA) ROOF RUNOFF �, \ / \ � \ MAIN HOUSE AND ACCESSn� 2929 4,288 SQ,FT, X 0,161 X 1.0 = 1110 CU,FT, SECOND FLOOR 180 1462 \ STORAGE VOLUME REQUIRED = 111,0 CU,FT, FLOOR AREA TOTAL\ 1806 �^USE: 5084 \ / i / \ 630 -I Q 3 - 8'0 X 6,0'H, 16,0� LIQ, DEPTH) COVERED PORCH 218 � O STORAGE VOLUME PROVIDED = -i60,32 CU,FT, REAR DECK / PORCH 199 168 t TRIBUTARY II- GARAGE 616 M }- O DRIVEWAY PARKING AND MANEUYERIN = AREA RUNOFF: FRAME SHED •1 246 (�/ Z \Q }- °\� / LL 0 1 3851 SQ,FT, X 0.161 X 1,0 = 643,12 CU,FT, m O Ill 13 (3 � G � FRAME SHED �2 320 t! . W O � Q STORAGE VOLUME REQUIRED = 643,12 CU,FT, \� x �r� `�� USE: FRAME SHED �3 I18 Z Z Z 0 Y 61,3 / / A ' 2 - O u1 z O O 350 T) Q U 4 F- x Fti � \ � 0 �,�p-���. 8 0 X 8,0 H, 18,0 LIQ, DEPTH) POOL HOUSE � �_ � Q 4, ,�� STORAGE VOLUME PROVIDED = 615,84 CU,FT, POOL HOUSE PORCH 150 L" O 0¢4'¢\J UTA T I P N a Q a U � TR B RY III- g Co POOL, POOL HOUSE AREA RUNOFF: SAUNA w W tu Z O O 00 L 144 O } 14 OO O Q t!i POOL: 800 S,F, X 4 AVG, DEPTH = 3200 CU,FT. 8 8 5,841 ' LL O *'/� ) = 320 CU,FT, O (L !� N 1�V G *( �c�����,q \ \ \ / / � ¢0� 3,200 X l i0�o .� Q.. (L� W ' `l ,per \ / / \c'` STORAGE VOLUME REQUIRED = 320 CU,FT, IY Q V LLGROSS FLOOR AREA cALICULATIONS ! US / POOL PATIO: 7SD 4' TALL FENCE \ \ i S O N 3,600 SQ,FT, X 0,161 X 1,0 = 601,2 CU,FT, ACRE SIZE 43,560 S.F. �`- !M DRAT AGE CALCULATION • l� � ° / STORAGE VOLUME REQUIRED = 601,2 CU,FT, TOTAL LOT SIZE 4,3108 ACRES O PROPOSED DEER FENCE � '' '' tt U O VOLUME = AREA x RAINFALL x COEFFICIENT 181,118,448 S,F, 80,000 107118, 448 S.F. J-1-� Z j J POOL HOUSE: - I 9 RAINFALL = 2,0" = 0,161 400 SQ, FT, X 0,161 X 1,0 = 66,8 CU.FT, 280-201 2,5% cQ SRio / �\ COEFFICIENT OF STORAGE VOLUME REQUIRED = 66,8 CU,FT, (F) UP TO 1,100 S F, x 2,5% LOT AREA IN \ �}+ XCESS OF Q -PERVIOUS GRAVEL DRIVE / PRKG = 1,0 200,000 S.F.SFt V � � /�� �` -ROOF AREA = 1.0 SUB TOTAL FOR POOL, POOL PATIO AND POOL HOUSE: 80000 S.F. ,,^ S I�� ����� �T „� `�� STORAGE VOLUME REQUIRED = 988,0 CU,FT, 2,694,4612 S,F, 2,694,4612 S,F, P'4GE' lv /Y' O AREA OF: USE: ALLOWABLE GFA 9,194,4612 S.F, ENTIRE LOT 1" = 30-O" \ -ROOFED OVER AREA AND IMPERVIOUS STRUCTURES � / 0 O 'COW �, -SEMI PERVIOUS STRUCTURES 3 - 8'0 X 6,O'H, (6,0' LIQ, DEPTH) �/ 15 10 O 30 60 111 \� -PERVIOUS GRAVEL STORAGE VOLUME PROVIDED = 1013,16 CU,FT, SCOPE OF WORK:120 n GRAPHIC SCALE P' . 30'-0" / �1 G(y`�\� -DRIVE / PARKING AREAS 1• DEMOLITION OF EXISTING DILAPIDATED DWELLING AND ACCESSORY STRUCTURES COSTORAGE VOL, REQUIRED: 2,323.12 CU,FT, 2. PROPOSED NEW DWELLING IN GROUND SWIMMING POOL AND DETACHED ACCESSORY, V A� 0 ,00 vJ � , Q STORAGE VOL. PROVIDED: 2,449.92 CU,FT, 3, RELATED UTILITY WORK INCLUDING: NEW SANITARY SYSTEM, WATER, ELECTRIC AND GAS, 4. ADD ACCESSORY BUILDING (DRY / SAUNA), DEER d PRIVACY FENCING a DRIVEWAY GATE VJ THESE DRAWINGS AND ACCOMPANYING SPECIFICATIONS,AS INSTFRUMENTS OF SERVICE,ARE THE EXCLUSIVE PROPERTY OF THE ARCHITECT AND THEIR USE AND PUBLICATION SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED.REUSE,REPRODUCTION OR PUBLICATION BY ANY METHOD,IN WHOLE OR IIN PART,IS PROHIBITED EXCEPT BY WRITTEN PERMISSION FROM THE ARCHITECT.TITLE TO THESE PLANS SHALL REMAIN WITH THE ARCHITECT.VISUAL CONTACT WITH THEM SHALL CONSTITUTE PRIMA FACIE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. Q WIND-BORNE DEBRIS 10ROTECTION s,b NOTES: WOOD I ' AA **'� 12 FASTENER SPACING (INCHES) o OI` WOOD Sti�l�Ctl�i� 1. �f"�I� � I, ALL WINDOWS TO BE LEPAGE MILLWORK, 'XL WOOD', RED GRANDIS FRAME. SASH: PUTTY GLAZE EXTERIOR, w w u COLONIAL GRILL INTERIOR, EXTERIOR 'FIRST COAT' IN BLACK, INTERIOR FINISH T,D.B. BY OWNER, FASTENER TYPE PANEL 4 FEET s 6 FEET s = LL FOR WALL OPENING PROTECTION OF120 MPH 3-SECOND WIND GUSTS SPAN PANEL SPAN PANEL SPAN 2• EXTERIOR CASING: TO BE 5/4" X 4" HEMLOCK TO MATCH SIDING. INTERIOR CASING BY OTHERS WITH 1 3/41, l MAXIMUM MEAN ROOF HEIGHT: 35') s 4 FEET s 6 FEET s 8 FEET HISTORIC SILL NOSE. SILL HORNS t0 FINISH FLUSH WITH EXTERIOR CASING, a z F 3, GLAZING TYPE: 3/4" DOUBLE GLAZE CLEAR SIMULATED DIVIDED WITH BLACK SPACER BARS, PROVIDE LOW-E o 0 0 NO,0 WOOD SCREW 212. TEMPERED AS REQUIRED BY CODE. SHUTTER ASSEMBLY o Q o FOR PANEL SPANS: BASED ANCHOR W/ 2-INCH 16 10 8 4, WINDOW SCREENS: PROVIDE WOOD SCREEN SURROUND ON ALL OPERABLE UNITS. FINISH BY OWNER, HUNG TO W 9 d 0 < 4'0 WIDE SPAN EM51EDMENT LENGTH FRAME, FULL SCREENS WITH CROSSBAR AT DOUBLE HUNGS, SCREEN COLOR TO BE BLACK ALUMINUM, z u 5, HARDWARE: TYPE AND FINISH TO BE SELECTED BY OWNER. _ 23/32" APA SPAN-RATED 48/24 SHEATHING GRADE PLYWOOD NO.1(0 WOOD SCREW 6, ALL INTERIOR DOOR/WINDOW TRIM, FINISHES , AND COLOR TO BE SELECTED BY OWNER. tu (OVERLAP AROUND OPENINGS 4") BASED ANCHOR W/ 2-INCH 1(o 12 9 ASSEMBLY: EMBIEDMENT LENGTH WINDOW PERFORMANCE DATA: � 8 1, FOR THE MOST CURRENT PERFORMANCE DATA SEE LEPAGEMILLWORK, THERMA-TRU AND UPSTATE DOOR CO, ATTACHING STRUCTURAL PANEL: FASTEN TO BUILDING w/ Q ALTERNATIVE FASTNER FOR SHUTTER TO BUILDING: 1/4-INCH LAG SCREW 8, ALL WINDOWS AND DOORS MUST MEET DP 30 (140 MPH) TESTING CRITERIA, S. WINDOWS AND DOORS MUST MEET OR EXCEED U-FACTOR OF 0,55, 0- d 010 TEE NUTS ATTACHED TO BLDG. w/ 0I0xl-1/2 ( W/ WASHERS) BASED ANCHOR W/ 2-INCH 16 16 16 = uw MACHINE BOLL 12" O,C, EMBIEDMENt LENGTH 10, ALL GLAZED FENESTRATION MUST MEET SHGC MAX = ,40, PROVIDED SHGC = ,21 0 11, FOLLOW I EPAGE INSTALLATION GUIDELINES FOR STAINLESS STEEL JAMB CLIPS FOR HIGH WIND INSTALLATION, N t 12, WALL OPENING (WINDOWS AND DOORS) PROTECTION (WIND DEBRIS PROTECTION 140 MPH) SHALL BE 10 o FOR SI 1 INCH=25,4 MM, I FOOT=304,8 MM, I POUND=4,448 N, w 0- PROVIDED WITH WOOD STRUCTURAL PANELS TO CODE. N o I MILE PER HOUR=0,441 M/S, o a SHUTTER ASSEMBLY 13, CONTRACTOR TO VERIFY ALL EXISTING WINDOW AND DOOR OPENINGS PRIOR TO WINDOW AND DOOR SH ,„OP t a a FOR PANEL SPANS: APPROVAL. Z •r $ a 4' OR WIDER SPAN a, THIS CABLE IS BASED ON 180 MPH ULTIMATE DESIGN WIND SPEEDS, 14, WINDOW FALL PROTECTION SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS R312,2.1 AND R312,2.2 ° yr-I; AND A 33-FOOT MEAN ROOF HEIGHT, 15, PROVIDE EXTENSION JAMBS AS REQUIRED FOR WALL THICKNESS, Q o 23/32 APA SPAN-RATED 48/24 1" FAASTENERS SHALL BE INSTALLED AT OPPOSING ENDS OF THE WOOD STRUCTURAL SHEATHING GRADE PLYWOOD PANEL. FASTENERS SHALL BE LOCATED NOT LESS THAN I INCH FROM THE EDGE OF THE NOTES, (OVERLAP AROUND OPENINGS 4") MULTIPLE SECTION 1, REFER TO PERMIT SET FOR MAIN HOUSE 2x4 STRONG-BACKS 6 24" OC �� ASSEMBLY: PANEL. T-X d A-5,X SERIES SHEETS FOR NOTES AND DETAILS 1/4" THICK BOLTS � C 2' O c, ANCHORS SHALL PENETRATE THROUGH THE EXTERIOR WALL COVERING WITH AN EMBEDIMENT LENGTH OF NOT LESS THAN 2 INCHES INTO THE BUILDING FRAME, FASTENERS _J ASSEMBLY: SHALL EBE LOCATED NOT LESS THAN 2-1/2 INCHES FROM THE EDGE OF CONCRETE BLOCK 1), PREASSEMBLE PLYWOOD TO OR CONCRETE. 2x4'5: * Iox3" (w/ WASHERS) d, PANELS ATTACHED TO MASONRY OR MASONRY/STUCCO SHALL BE ATTACHED USING GALVINIZED OR STAINLESS STEEL VIBRATr10N-RESISTANT ANCHORS HAVING AN ULTIMATE WITHDRAWAL CAPACITY OF NOT WOOD SCREW 6 12" O.C. LESS THAN 1,500 POUNDS, 2), ATTACHING STRUCTURAL PANEL: FASTEN TO BUILDING w/ 010x3" (w/ WASHERS) GALVINIZED OR STAINLESS STEEL WOOD SCREW tv 16 � � ��m O,C, hll£, �r. i mmission ALTERNATIVE FASTNER FOR " ``{� o SHUTTER TO BUILDING: �y"y�j't�� 'b;a " 010 TEE NUTS ATTACHED TO BLDG. f �� TYPICAL ROOF CONSTRUCTON: w/ *IOxI-1/2 ( W/ WASHERS) MACHINE - 2X WOOD RAFTER PER PLANS BOLT 6 12" D,G. - 5/8" CDX PLYWOOD SHEATHING (ZIP m SYSTEM OPTION) cil - WEATHER BARRIER %SHUTTEfR AS' C6E 5LY0 - ICE AND WATER SHEILD TO CODE �O - ASHPHALT ROLL ROOFING TO MATCH N,T,S. r ' r MAIN HOUSE (BLACK), QC m 2X10 R.R. m 16" O,C, ASHPHALT ROLL 4 p ASHPHALT ROLL �/ O \0 1O ROOFING t0 MATCH „ „ ROOFING TO MATCH �� U � W m X 1/2_' 12 OGEE GUTTER MAIN HOUSE (BLACK), / 1/2 / 12 MAIN HOUSE (BLACK), i/2" / 12" OGEE GUTTER W � To, PLATE SSA , , , ; ; , , , , , , , T.O. PLATE --- -_ _- -- - FASCIA: 1X8 W/ XO Z T,D, WINDOW - - - - FASCIA: IXS W/ z ! f�- f0 IN ULAtIoN I � If CROWN TO MATCH M O O / DOOR _ r ! GROWN TO MATCH p - WAINSCOT SOFFIT TO EXISTING EXISTING MATCH MAIN HOUSE - I1NTERIOR FINISH 4 TYPICAL WALL CONSTRUCTON: PAINTED WOOD SOFFIT z4"xz4" z4"xz4° PAINTED WOOD SOFFIT 24"xz4" [� Q- (� N z EQUIPMENT BY - - 2X6 WOOD STUD W/ 1'-O" OVERHANG W/ 1-O OVERHANG I Q O ° - I/2" PLYWOOD SHEATHING s4°x66" eo°x66° I 28°x84 Ix4 TRIM ; SAAUNA INSTALLER PICTURE Ix4 TRIM PICTURE aD - WEATHER BARRIER HIDDEN DOOR 8"-10" VERTICAL m r - RAIN SCREEN (BLACK) 8"-10" VERTICAL i - 1 x 8 t10 VERTICAL BOARD SIDING, BOARD SIDING �' BOARD SIDING I LEFT TO WEATHER. PARGED EXPOSED , PARGED EXPOSED GRADE / - - - GRADE / GRADE / - CONCRETE - <t - - - GRADE / - CONCRETE W IN, FLOOR �t `t tt tt I� I _ _ G A O GRADE 00 CK POOL DECK FOUNDATION �OL�E POOL DE FOUNDATION a a POOL DECK DROP WALL FOR SLAB ARCHITECT: - SAUNA NORTH SA 2" RIGID INSULATION SAUNA WEST EL. UNA SOUTH SAUNA I� I -}-EL. � Bit 114111 O 1/4 I O 1/4 1'-0" 114" = 1'-O" �° ,,I�`�\ SAUNA &ECG"ION PROVIDE TIE DOWNS AT EACH CORNER SIMPSON HDU 5 (TYPICAL) - 12' O" SEE DETAIL SHEETS 5/8" ANCHOR BOLT. PROVIDE 4 1/2" MIN WOOD MEMBER TO ATTACH TO OBTAIN 1810 L55 RESISTANCE DANIEL A. BUTLER, R.A. PROVIDE 5/8" ANCHOR BOLTS 32" O,C, MAX, WITHIN I' OF EACH 8' - ell SPLICE IN SILL PLATE J 5 9/16" 1141,61 3' - 3" SEE DETAIL SHEET FOR INSTALLATION ~ Q Q �, OGEE GUTTER 1 _ O" 11.1 Q c; i 1/4 I32,01 r- -- ---54°x66" ---- -------------- -- O 3 5/116" I84.31 - I PICTURE I - - - - - - - - - I I A4 j 11/8" I48,01 ASHPHALT ROLL r - - - - - - - I Z Q ROOFING TO MATCH J J 11/4" [32.OJ MAIN HOUSE (BLACK), T - I I 1 O It LL } ca � 1 1/8 [48.0] o -! w I I I � I I l a I Z x 1 I I I I UNEXCAVATED I 8" P.C. WALL ON 8"x16" Q O O 1 13/IC" [46,1] - SAUNA I I _ _ I U 4 f Q- - 2 0,3] cz - Q! a (2 STONE PAVES) X i O c4 I SLAB ON GRADE I PO -3'-0OTIN OW A Q W U Q �., O I i I I I I I BEL GR DE p/ `n m I I `' OR RATEABLE SOIL, `4 8'-O" CLG. HTt w t~o uz 00 1-1 LL 0 3/4" [I9,0] 10 0] O r DROP c/1 4C,Oh N4 _ FOUNDATION 5 /16 I14 ] *• O a - n I FOR SLAB �O 0_ N U o 0 4° P.G, SLAB ON GRADE V � HEALER L _ - - - - - - - (350�0 PSI MIN,) W/ 6 X6 10/10 W,W,M, ON ro MIL VAPOR BARRIER ON - L- ----24- ------ - w O --- 24"x24"---- -J - - - - - - - - - - - 2" RIGID INSULATION BOARD C14 .. 3 3/8" 3 3/8" o I HORIZONTAL AND O [85 3] VISIBLE GLASS 105,31 all ,10 8 U_ VERTICAL t0 FOOTING) z •• 1 3/116" [I82,5] 4° MIN, COMPACTED 16,001, 1/a" 122,11 - FRAME SIZE 12' - O" � POUROUS FILL Q a0 N SECTION A - A SECTION 1 - B ¢ ¢ ' 511 PAGE, 00 N ul co .J ul S,�l�1�1 i�00 PLAN SAUNA �OOfi� PLAN SAUNA FOUNDATION 1 �'1.._AN XL DOUBLE HUNG UJ/ ALUMINUM CLAD. 3 9 A�2407 2 1 Lo N 3" = 1'-O" 1/4" = I'-O" 1/4" = 1'-O" 1/4" = 11-0" o N N O THESE DRAWINGS AND ACCOMPANYING SPECIFICATIONS,AS IINSTRUMENTS OF SERVICE,ARE THE EXCLUSIVE PROPERTY OF THE ARCHITECT AND THEIR USE AND PUBLICATION SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED.REUSE,REPRODUCTION OR PUBLICATION BY ANY METHOD,IN WHOLE OR IN PART,IS PROHIBITED EXCEPT BY WRITTEN PERMISSION FROM THE ARCHITECT.TITLE TO THESE PLANS SHALL REMAIN WITH THE ARCHITECT.VISUAL CONTACT WITH THEM SHALL CONSTITUTE PRIMA FACIE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. Jeffrey T. Butler, P.E., P.C. 206 Lincoln Street Architectural and Engineering Services Riverhead, NY 11901 Tel: (631) 208-8850 Fax: (631) 727-8033 July 28,2024 � . D JUL 2 2024 Historic Preservation Commission HISTORIC PRESERVATION COMMISSION Town of Southold P.O.Box 1179 Southold,NY 11971 Re: rAsip-I ouse-=82'55Mrid-ge.,Lane.-Cutcho ague(1000-84-1-4.6) -REVISION Dear Members of the Board, Attached,please find revised plans for the proposed project. As we continue to progress with this project the client has a few changes that we would like to submit for your review and approval. 1. Extend front porch depth from 6'-0"to 7'-6". 2. Add 4'-0"deep covered rear porch with 6"wood columns and brick porch. 3. Pool house expand to allowable 350 s.f. limit.Extend front porch to 7'-6" The remainder of the house remains as approved. We believe this makes the porches more usable and doesnt adversely effect the massing or proportions visible from the street. Thank you for your consideration. Sincerely, Daniel A. Butler,Architect �I PloillnoS ao umo. ; ouquedea Bulpllna Rod 9 t AV U M a � acel 0 mQ � E ; w m Wo HORIZONTAL x CEDAR FENCE RAILS AND CAP E&NX NfR;zocitylT 1X6 CEDAR W/ Q� 1.5" SPACE 0 1 11211 6X6 CEDAR POST `9 IEL 9 W/ CAP SELF-CLOSING, SELF — ~ LATCHNG PEDESTRIAN 9 GATE TO CODE, a � o 12" POURED M W W } CONCRETE FENCE A ° o m 'o FOOTING TO FROST z 3 � W wzQo Q d 4-0"MIN, DEPTH (3'-0" MIN.) p z U - F- o a Z au4 Cil O N w iu O O >4 uz4i ' O Q H N N FRONT ELEVATION SECTION A � o POOL CODE COMPLIANT FENCE AND GATE � d z w m a o Q I PRIVACY PENCE DETAIL PAGE: A - 0 . 3 weT�A/gnc-0rydAmm /� -IX19T.CP TO BE �V�r`( "r iw.cyl0tt.oxn /' \\ ABANDONED PER LC�'�A�.}An ED �\ {V/ 9 (brou:x at3tas) /� SCDH9 REGB. �pROPCB Ip00 GALLON ZONING \\/ UNDERGROUND PROPANE TANG B^)✓"Z9Z'I UV I JII _ �oY // \ %62.1 i♦\//-EMERGENCY GENERATOR BULK SCHEDULE FOR RESIDENTIAL DISTRICTS \\\\ Bylaw,e%caraips antl cato-dctors Xvrki Bin For sanelyreasons,lrotrPswnere are ttsangly EXIST, ,pv ,�y '` DISTRICT A-0 the five boroughs Of Nlrw York Ciry and Nessau umgedrocAl as Hml when plannk9 rry �' WELL 4(Rti4. IX15T,O.N.SERVICE BE ABANDONED. MM.REQUIREMENTS FOR 1-FAMILY DETACHED v R6", �\ \\ \\�F and ,,CounWX on lmg Wand must type o/o'gging on lhe'v PraOertY tbrowmws O I �{� �P♦(/ /\// / \ i/ MOVE IO NEW UNDERGROUND SERVICE co48 OlgNek/-000.272440g w811.9t least tan contact us directlystt-800.2)24400«q ��t 2 ''�• (� DWELLINGS 48 bees butrw more glen iDxaking days .Trigelttne natloral mll be(pe ycV diB �`� I ��tl _. >♦, (awuair:e weak«ns roMgel tw0days pti«m camber.F«ecavetim vwkcomgetea an O 9•Q\ , �� 1' a \ 9 -OANITARYPROPOSE SYSTEM ROOM LOT SIZE(SQUARE FEET) 80,000 beginNng enymetlanlzad dggNg«aueNagon pBtsorel preperry,It is the mlNeUors / 1,5 g w«kto anwre uMergrounG laws era madesd. resporlslbLq�l071he�e-ne Pocomact ' R/ C-,; ' ♦'��N _ LOT WIDTH(FEET)Ezcevatare and WNratlors een elsosubNl DI Net HeYlag u, IFesmeq.. rbrb � 115 locate requests Mire,Wough TTIC.Ifyou do diggag is bee oleharge. / `l I N07E:FOR SANITARY AND STORM DRAINAGE not anerWY Mse mcl please cou / \O G"/l LOT DEPTH(FEAT) \' DE91GN BEE SHEET 0PIf2 OF THE APPROVED &� \\ 1-BOD 6247603 for more IM«mauon. `-� ex-0,H.9 017E PLAN,64,C).H,9.REFERENCE SITELOCATION FRONT YARD(FEET) _ NO.r R-Y40943,DATED IV6/4074. PRIMARY FRONT YARD(FEET) 60 BY.ttcDONALD GE08CIE14CE PROPOSED CONTROL PANEL AND BLOWER:--��!' _/// z c- 5[ \ N BEOONDARY FRONT TARP(FEET) 40 0 DATED:3/4R024 8EE'CONTROL PANEL REQUIREMENTS' / lub'c:a:� tag?•% ! SIDE YARD(FEET) - 20 THIS DWG.FOR MOUNTING DESIGN AND EXIg7, 99 E`x\ /°/e% Y,� \,/� EXIST.2 STORY FRAME DWE LING 00TN SIDE YARDS(FEET) 45 - EL.62.5' GRADE 0,0' REQUIREMENTS -/ •'\ TO BE DEMOLISHED Q CPI �� ♦ f p' !'.?: REAR TARO(FEET! _-� -SEE PROPOSED'H'FRAME DETAIL',ON DWG ISM EL, • 15-- EL,61.5' DARK BROWN LOAM OL / /®♦ \ /-')\t , / I'BELOW GRACE PROPOSED AC CONDENSING WHIITS �' ®_ �\ \ Yl .� / ➢�'�',bi / \ LIVABLE FLOOR AREA(SQUARE FEET PER DUELLING UNIT) 850 '_ -- ea nav~ \, p♦ ' ♦ / ` i �9 \o --_- MAX.PERMITTED DIMENSIONS X a EL 56.5' // \ / �\ `E /r'•4'♦\ytx p'3. / \\ �LQ�4 NO WELL 1 BANITART GROWN SILT ML EXIO7/fR BRED 3-� I a+e•c:a. � /a r..y T\♦ xl, � ♦ \ \ SYSTEMS CEWIT A I50 FT, IpT COVERAGE(PERCENT) 4'BELOW GRADE TO BCE DE^OL13HID / IN SD I_ \ \•\�1j, R`)� ♦ !� \\ \ '\o NO SURFACE ACE 20_ / / ``�\' T., \ � ♦� \ WATERS WTHIN 300 FT. BUILDING HEIGHT FEET) - 3545 / \ NUMBER OF STORIES EXIST.FIR 6HED 9 TO- /-/ " \,/ •co.xs ♦ 1•V2 BE D?70115HM / i \. " \` .•J�'\ r �\ NOTES, -LOCATION MAP l/ / / "� \\ •� \�' \ N I,6EE TEXT OF CHAPTER AND DENSITY AND MIN.LOT SIZE SCHEDULES FOR GROWN FINE SAND$P \\ tir. - --- // EL 45.5' 17'BELOW GRADE !/ `/ / ) \ r \ \ TES7 ,��/\`'' APPLICABLE DISTRICTS. 4 -- -- \ \ ` / ♦\ HOLE yO',p{ ♦ �\ 4.SEE LIMITS TO GROSS FLOOR AREA(GFA)IN T803. ♦ ', / \ 62'3/Q�W/S`e' \ ♦ J� \ 5.BUILDING HEIGHT FOR ALL DISTRICTS:35 FEET TO PEAK OF SLOPING DATA NO GROUNDWATER ENCOUNTERED EL.45,5' / '\• \ -v -_/tl/ ROOFS,25 FEEL FOR FLAT OR MANSARD ROOFS,SEE DEFINITIONS, SITE L/ATf'4' �/ �44 HIGHEST EXPECTED GROUND WATER o EL 11.26'PER !! „(/�°'apt/ , /� m / 0 p ra(\ \ - ♦ O (� 6.ROOFS MUST BE WITHIN THE SKY PLANE,SEE DEFINRIONO. - WELL MONITOR STATION 553324,1 GJ' Pt, / 4 \♦y-. - �N \ 51'NATE AT: _ .� `�.i \/ ♦ �i '<' 9 `A / 8255 BRIDGE LANE r TEST HOLEL: o�� \. �C�t eureHOGu$NY Ins .F- - N.T.S. , _L '� ♦ /� TOWN OF SOUiHOLD / ' R t e'ac. 1-• �., ( \ /e°'; 6 \ O\ ))' 150'FROM EXIST. COIA+n of 511Ffouc a so ecy\ ♦ / \ j ADJACENT WELL SCTM s:1000-084-01-004.6 ZONING DISTRICT:A-C 1. a \ O \ to PRoposED TY QD' POOL- S �� / \ a...• "e,r, �' 1,� \ \ --_ _--- APPLICANT/dynyERr CABANA(DRY)W! ♦ - `,QpC1� / \ \ RICHARD B.6AC45 CO a^ VERED PORCH CEO /j / 4Q• / \ \ 67EWART TITLE INSURANCE CO. -P0�� / / ♦ 7 SITS DAre, Y bT� / 1 001:•EQWPMENT-PROPOSED- R 150,_0. AREA OF SITE:4JI08 ACRES e� cAREA NEW WELL PRINCIPAL BUILDING OR 07RUCTURE,MIN.YARDS(FEET), W U- �� LOC4T101 W / ` EXIST,FRAME SHED•1 '- - ♦\ /// N RE(3tURmr EXISTING PROPOSED: x \',\ FRONT 60.0' 43.5' bib' F Q 4'%e'sLae FOR 70 BE DEMOLISHED \\ / ♦ BIDS. 20.0'/45.0' SO.1' 45.0' / GARBAGE BM EXISTING WELL TO ♦ / REAR• 15.0 381,5' C15.0' O BE ABANDONED �`''x 626 d c HEGHi• 35'/2 STORY 2 STORY 2 STORY(2B'-0°) Q-O(p / \ /' ♦ ! ' 1 ACCESSORY BUILDING OR STRUC !{ t,\ - REQUIRED: N�EXIISTING 8[f ThPROP08ED: i0 / ♦\ \ / ! / \ SIDE.. 25.0' 5R5' 64.13' ♦ N / /, // / REAR• 2S.0' 211.9' bl 5 / ♦ \ / / � ♦ MAXIMUM ALLOWABLE HEIGHT FOR ACCESSORY STRUCTURE FOR A LOT \ ♦ 80,000 S.F OR OVER IB 22'MAXIMUM HEIGHT \\ / ///.� Y� \ SURVEYED BY, ARCW T, \\ $ `♦\/ \ ///' // / V SMITH,JUNG4 Gst L; q p \\\ PROFESSIONAL LAND SURVEYOR ` ° VW/ 120 MEDFORD AVENUE ,/ D DELL PATCH'OGUE,NY 11T12 / \ 631.415-3H2 150'FROM EXIST. \♦ AUGUST rk 2022 ADJACENT WELL ,AREA CALCULATIONS: \ / ,/ LOT COVERAGE cANEL 4 euT Ea�A. �3, EXISTING PROPOBm / ♦\ , /' MAIN HOUSE 0 P� _- 1�,' \` ♦\ // / FIRST FLOOR 1p26 - �3 /,' FLOOR - LSO _ 1461 O �./ ♦ \ / / FLOOR AREA TOTAL 1806 r 51 _ COVERED PORCH 218 630 m r ems. (O dj \ ♦ /' I/ �` ,saQ,tU\ REAR DECK/PORCH 199 �B •�- Qi Z♦9 }• W 6e1RAGE b,b (K W O I 1 \ 61.3 ♦\ IlnO "/Y �gtP'`�Y FRAME ONES q 246 - z Z °Qff \ ♦ /`q"O so. / I�J 4P� FRAME EaIED 4 320 OI Q N HOI U v4 OC d N \ / F ��/ ✓' FRAME SHED-3 g{\•Q•�♦ FY0. POOL 4OUSE --_ ---- 'D ------- (V W ppO W3 °F ° POOL HOUSE PORCH o - GQ ]g Q 4r� \\ \♦\ ./ / o TOTAL 2181 - 2586 5693 - --- o EL O GROSS FLOOR AREA CALCULATIONS z .�' ACRE SIZE 43,560 S.F, ap .. 3Q // TOTAL LOT 0QE 4.3105 ACRES _-_ W Z 181•T,8.448 S.F. BOp00 101,118.4-0B B.F, (v (�� 1- S � - - -- '-- 2.Stc LR- •3 0 V [F) TO - EXC LOT AREA IN -SITE PLAN - \\\ / Onj 200000 9.F. ,-IOD B.F- x EXCESS OF --- O PAGE: (/) __ 2,696.41,12 S.F.-- 7b94.46D 9.F. O ' ALLOWABLE GFA 9,794.46@ S.F, ENTIRE LO7 --`--- - GRAp41C SCALE !O 60 __.Y I°,90 O v h WORK-SCOPE OF / ` 1 O•O N t" L DEMOLITION OF EXISTING DILAPIDATED DWELLING AND ACCESSORY STRUCTURES .Vn� 2. PROPOSED NEW DWELLING IN GROUND SWIMMING POOL AND DETACHED ACCESSORY.THESE 3, RELATED UTILITY WORK INCLUDING:NEW SANITARY SYSTEM,WATER,ELECTRIC AND GAS, ik9 " o 1 WINGS ANDACCOMPANYINO SPECIFICATIONS,AS INSTRUMENTS OF SERVICE,ARE7FE EXCLUSIVE FRCFERTYOF 111E APCXRECTANDTNEIR USEAND PUBLICATION SHALL BE RESTRICTED TOME ORIGINAL FATE FORYr1sLH THEY WERE PREPARED REUSE.REPRODl1C71Wt OR PUSLICA7gNBYANY METHOD,W WHOLE OR M PART,IS PROHIBITED EXCEPT BYWRITTEN vERML0510N FROM THE ARCHITECT,TIRE TO THESE PLANS SHALL RBMNN WITH THE ARCJ0IECT.VISUAI CONTACT WITH THEM 3XALL CONSTITUTE FIRMA FACIE EVIDENCE OF ACCEPTANCE OF THESE 01/25/2025 2:34:20 PM RESTRICTIONS. s Woad APPROVED AS NOTED DATE;3-3 B.P# 5 I rl q I COMPLY Wf N AL CODES OF NEW YORK STATE&TOWN CODES FEE `�o� BY: 8=1 AND CONDMONS OF NOTIFY BUILDING DEPARTMENT AT SOUmvmzm 631-765-1802 8AM TO 4PM FOR THE smmTnkmom FOLLOWING INSPECTIONS: FOUNDATION-TWO REQUIRED FOR POURED CONCRETE '�5• a3.20ay.2 ROUGH-FRAMING&PLUMBING SOU�IOIDt�C S-aa-a INSULATION FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE ELECTRICAL REQUIREMENTS OF THE CODES OF NEW INSPECTION REQUIRED YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS "IMMEDIATELY" ENCLOSE POOL TO CODE UPON COMPLETION BEFORE"WATER" RETAIN STORM WATER RUNOFF PURSUANT TO CHAPTER 236 OF THE TOWN CODE 1 O.5" �+ 12" Coping Pavers Mortar 4" Compacted Sand 6" Tile 12" Bond Beam O Z" Marble Dust Concrete #4 rebar (4) #4 rebar 10" o.c. throughout cont. through verticals 5" o.c. where bond beam water depth exceeds 5' O O 12" TO 36" Radius Compacted Soil O O Minimum specifications; Shotcrete Gunite 4,000psi minimum Grade 40 rebar (conf to ASTM A615) All work to be in compliance with ACI-318 Y 4" min. thick 4" Gravel base o- w UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING AND RELATED DOCUMENTS IS A VIOLATION OF SEC. 7209 Of UIE N.Y.S.EDUCATION LAVI 2J�O o �8358� JOB#: binder Y�E ff DATE: 4.29.22 �yp Pool `' '�' SHER NGINEERING SCALE: AS NOTED ® ® 86 CONSULTING P.A. DRAWING NUMBER Cross O S S Section n F ST AUGUSTINE,FL AVENUE 84 1 2 v 631.831.3872 AFq'NC k Go�9 SACHS RESIDENCE 8255 Bridge Lane Cutchogue ; f f 20'x40' GUNITE SWIMMING POOL 4' to 6' depth I I 8" Shell, 14" Beam 4 RETURNS I 4 LIGHTS I j 2 MAIN DRAINS STANDARD AUTOFILL I I � � I 20' j I I I 1 I � E i HOUSE SIDE Drawn by Katy Binder, CBP March 19, 2025 Nq E R 4' 4'I3„ P 0 0 L S � I 6 3 I