Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
52961-Z
aOF SOpTyo`o Town of Southold * * P.O. Box 1179 ti o�Ml 53095 Main Rd Ulm Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 47289 Date: 08/13/2026 THIS CERTIFIES that the building AS BUILT ALTERATION Location of Property: 1670 Stars Rd East Marion, NY 11939 Sec/Block/Lot: 22.4-16 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 03/04/2026 Pursuant to which Building Permit No. 52961 and dated: 05/08/2026 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "As built" finished basement with bathroom to an existing single-family dwelling as applied for. The certificate is issued to: Andrew Kandel,Melissa Kandel Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 52961 7/l/2026 PLUMBERS CERTIFICATION: Joel Dal 6/12/2026 UIX., A ho ' ed oignture �o��ofSOUTyolo TOWN OF SOUTHOLD BUILDING DEPARTMENT • SOUTHOLD, NY coul BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52961 Date: 05/08/2026 Permission is hereby granted to: Andrew Kandel 112 W 18th St Apt 5C New York, NY 10011 To: legalize an "as built"finished basementto an existing single-family dwelling as applied for. Additional certification may be required. Premises Located at: 1670 Stars Rd, East Marion, NY 11939 SCTM# 22.-4-16 Pursuant to application dated 03/04/2026 and approved by the Building inspector. To expire on 05/07/2028. Contractors: Required Inspections: Fees: As Built Alteration $1,748.00 CO-RESIDENTIAL $100.00 Total S1.848.00 Building Inspector NY O��OF SOU���l � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 CA • Southold,NY l 1971-0959 �O �y,rOUNT`I,N BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Andrew Kandel Address: 1670 Stars Rd city: East Marion st: NY zip: 11939 Building Permit#: 52961 Section: 22 Block: 4 Lot: 16 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Electrician: AS BUILT License No: SITE DETAILS Office Use Only Commercial Indoor X Basement X Service Solar Residential X Outdoor 1st Floor Pool Battery Storage As-built X Renovation 2nd Floor Hot Tub EV Charger New Addition Attic Spa Generator Surrey X I Mezzanine Garagel IDock INVENTORY Service 1 ph In-wall Heater Recpt 21 Ceiling Fixtures 5 Smoke Detectors Pump Service 3 ph Hot Water GFCI Recpt 2 Wall Fixtures 1 CO Detectors Heater Main Panel A/C Condenser Single Recpt RecessdFixtures 23 Combo Smoke/CO Transformer Sub Panel A/C Blower Range Recpt Ceiling Fan Heat Detectors Salt Gen Transfer Switch Mini Split 1 Dryer Recpt UC Lights Fridge AutoCover ARC 3 Blower Heads 1 Switches $ Pucks Lights Dishwasher Mini Fridge GFI SepticDisconnect Emrgency Strobe 4'LED Microwave Garbage Disp. ARC/GFI 1 ERV Exit Lights Bath Exhaust 1 Hood Dehumidifier Other Equipment: Notes: AS BUILT NO VISUAL DEFECTS " Finished Basement Inspector Signature: Date: July 1, 2026 v~I FPO �' moo, �o . Town Hall Annex Telephone(631)765-1802 54375 Main Road o P.O.Box 1179 y, Southold,NY 11971-0959 • DOJUN 2 2026 BUILDING DEPARTMENT TOWN OF SOUTHOLD Buil;iittg I)epartrrterat Town of Southold CERTIFICATION Date:: �- Building Permit No. Owner: Kl-�t.1 D L, f}/J D Ya bL') m L 1J) (Please print) Plumber: (Please print) ' I certify that the solder used in the water supply system contains less than 2/10 of 1%lead. (Plumbers Signa ) Sworn to before me this day ofal/ln-� 20� Notary Public, U County' i CONNIE D.BUNCH F i, Notary Public,State of New York t No.01BU6185050 Quallfied in Suffolk County ^ 1 ' Commission Expires April 14,2 �cz`% i s r 50UlyO� # TOWN.OF.SOUTHOLD BUILDING DEPT. co 631-765-1802 <v000( INSPECTIO-N FOUNDATION 1 ST/ REBAR [ I ROUGH PLBG. [ ] FOUNDATION 2ND [ rSAULATIOWCAULKING FRAMING/STRAPPING [ NL a6w [. ] FIREPLACE & CHIMNEY [ ] FIRE-SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ]. FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: Ill �i�.6ey-C, © PIS, �� Cs-- 3 - 6earv�i 69 swnl(p- ir co v, &fz0,mtq,( DATE INSPECTOR ho�AOF SOUTyolo gL7C T WN OF SOUTHOLD DING DEPT. `ycouto, �o 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: (ZA c n4a rq COY-)n/J 4 61-a 9 P 4�a DATE INSPECTOR N. J. MAZZAFERRO, P.E. PO Box 57, Greenport,N.Y. 11944 Phone - 516-457-5596 Consulting Engineer August 10, 2026 Design, Construction, Inspection Page 1 of 1 Town of Southold-Building Department 53095 Main Road Southold,NY 11971 Re: Kandel 1670 Stars Road East Marion,N.Y. 11939 District-1000, Section-22. Block-4 Lot-16 Building Permit Number—52961 Alterations Inspection—Rough Plumbing On August 6, 2026, I inspected the basement construction at the noted location. The inspection covered the rough plumbing for the new bathroom in the existing basement. The inspection covered the interior plumbing roughing for the Drainage Waste and Vent System (DWV) and the Water Supply System(WS). The inspection results are: 1 —DWV—System was exposed and readily viewed. I observed the drainage and vent lines. System constructed as required. New installation is connected to the existing system. 2—WS—System was exposed,pressurized and readily viewed. I observed all hot and cold water supply lines. System constructed as required. New installation is connected to . the existing system. Result—Based upon inspection of this project and to the best of my knowledge,belief and professional judgment, construction as installed complies with the plans and applicable codes of the IRC,NYS and Southold Town Building Codes. Nicholas J.Mazzaferro,P.E. ���E )F NEty Y 5 0 PS .rat 2 3- O� 9�t^ It O �v 2�Fp 4,0. 05�095 p���ESSIONP� I N. J. MAZZAFERRO, P.E. PO Box 57, Greenport,N.Y. 11944 Phone - 516-457-5596 Consulting Engineer August 10, 2026 Design, Construction, Inspection Page 1 of 1 Town of Southold-Building Department 53095 Main Road Southold,NY 11971 Re: Kandel 1670 Stars Road East Marion,N.Y. 11939 District-1000, Section-22. Block-4 Lot-16 Building Permit Number—52961 Alterations Inspection—Framing and Insulation On August 6, 2026, I inspected the basement construction at the noted location. The inspection covered the egress, framing and insulation for the interior walls in the basement of the existing house. The areas inspected in the basement included the walls and ceiling and exterior egress. The framing and insulation work included the exterior, interior walls and ceilings. The basement has an egress door and staircase that conforms to the current code. The inspection results are: Items inspected included lumber size, dimensional spacing, connections, and integration with the concrete foundation. The insulation placement was verified. The insulation(R- 10 walls R-30 ceiling) meets code requirements as of the time of installation. t Result—Based upon inspection of this project and to the best of my knowledge,belief and professional judgment, construction as installed complies with the plans and applicable codes of the IRC,NYS and Southold Town Building Codes. ;....;_ µ.me.,. OF NEW y Nicholas J. Mazzaferro,P.E. q� 0 x �2s No 05709h ARaFESs1Ot4 vv Joel Daly From: Jake LaChapelle <jake@lachapellearchitecture.com> Sent: Friday, May 22, 2026 12:02 PM To: Joel Daly Subject: Trimmer Joist Detail - 1670 Stars Road Attachments: 2026.05.22 CSK-02-03_Trimmer Detail_1670 Stars Road.pdf Joel, Two details are attached for the conditions observed yesterday-see pdf. Option ►�-flit Cutting the doubl� mer joist reduc apacityto carry the stair loads above.The remaining joists are heavily notc ell. One option would be to add large steel flitch plates. Assuming you don't wan et into I've provide t e sec Option B-post and footing This option is relatively straight-forward. -The 2x4 post isn't adequate. Replace with a 4x4 post(not two 2x4s). -The load at the slab has been increased by reducing the capacity of the trimmer and transferring to the post.The archive drawings for the house don't indicate a footing in this location,just 4"slab. The slab may crack under the increased load. If you can confirm a footing there then it may be okay. If not cut the slab and provide a 22"x22"x10" concrete footing under the post, reinforced with (2)#5 bars in each direction. - Patch the notches in that 2x6 trimmerwith additional 2x4 at each side. Let me know if you have other thoughts. Thanks, Jake Jake LaChapelle AIA NCARB LaChapelle Architecture P.O. Box 1251 Mattituck, NY 11952 jake@lachapellearchitecture.com ' (646) 251-5058 c (631) 407-0507 o i r' ,. Provide flitch plates; oonwll A for size and lwlUrg pattern CSK-02 5/22/2026 1670 Stars Road 2 FIELD INSPECTION REPORT I DATE COMMENTS p� 'C FOUNDATION (IST) ------------------------------------ COO FOUNDATION (2ND) z — o G H ROUGH FRAMING& PLUMBING y 6� �l r INSULATION PER N.Y. y STATE ENERGY CODE CRAl IN(j . FINAL /!�/►(f� �h bS . ADDITIONAL COMMENTS b � H O z x . H x d b y i g�yff0(� o� coo TOWN OF SOUTHOLD-BUILDING DEPARTMENT s= Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765-9502 hqps://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT 5 For Office Use Only 'z PERMIT NO. Building Inspector: Applications and forms must be filled out in their entirety..Incomplete 1 y C: MAR - 4 2026 applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date:2026.02.26 ry OWNER(S)OF PROPERTY: Name:Andrew Kandel SCTM#1000-22.-4716 Project Address:1670 Stars Road, East Marion, NY 11939 Phone# (g17) 716-4721 Email:akandy@g_Mail.com Mailing Address: above CONTACT PERSON: Name: Jake LaChapelle AIA_- - Mailing Address: P.O. Box 1251, Mattituck, NY 11952 Phone#: (646) 251-5058 _ Email: jake@lachapellearchitecturecom DESIGN PROFESSIONAL INFORMATION: Name: Jake LaChapelle AIA_ Mailing Address: P.O. Box 1251, Mattituck, NY 11952 Phone#: (646) 251�5058 _ _ Email: jake@lachapellearchitecturecom CONTRACTOR INFORMATION: Name:Joel_Daly,-Joel Daly General Contracting_Inc Mailing Address: 205 Boisseau Ave, Southold, NY 11971v� Phone#: (631)-765-1223_ Email:Joel@joeldalybuilders.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition RAlteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $10,000 Will the lot be re-graded? ❑Yes RNo Will excess fill be removed from premises? ❑Yes ®No 1 PROPERTY"INFORMATION. Existing use of property: single-famil residential Intended use of property: no Change Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R-4� this property? ❑Yes BNo IF YES, PROVIDE A COPY. 8 Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuantto the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws;ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class;A misdemeanor pursuant to Section 210AS of the New York State Penal Law. Application Submitted By t e •Jake LaChapelle AIA I3Authorized Agent ❑Owner Signature of Applica Date: 3 ZOZL CONNIB D.BUNCH Notary Public,State of New York STATE OF NEW YORK) No.61BU6185050 SS: Qualified In Suffolk County COUNTY OF ) Commission Expires April 14,2- being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. rSworn before me this (}� day of �GI\CJ' 1 .20L IV--r Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) 1 Andrew Kandel residing at 112 W 18th St, Apt 5C New York, NY 10011 do hereby authorize Jake LaChapelle to apply on my behalf wn of Southold Building Department for approval as descri ed he ein. �-G I Owner's Signature Date Andrew Kandel j Print Owner's Name 2 I i I i I I EC OFF0[�-�Q D BUILDING ARTMENT- Electrical Inspector WN OF SOUTHOLD c J UToW1 R 14WAn nx - 54375 Main Road - PO Box 1179 o • Southold, New York 11971-0959 Building DepartmentTelephone (631) 765-1802 Town of Southold APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 12 Company Name: Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: ^I3 T sj- ri 5 5 A- sL -�L Address: l (o`7 D 6-s T /-i A-C-11 C 5 3S Cross Street: mA i Phone No.: Bldg.Permit#: 5 a IT 6, ( email: Tax Map District: 1000 Section: a Block: 4 Lot: ( �v BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): gn s l; Mc-a 7- — C* Square Footage: SQ Circle All That Apply: Is job ready for inspection?: YES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 D H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION FFp( i� BUILDING ARTMENT- Electrical Inspector WN OF SOUTHOLD J%W'w 49?16Ann 54375 Main Road - PO Box 1179 ` Southold, New York 11971-0959 p� Building DapartmentTelephone (631) 765-1802 Tow.-n of Southold APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: o2, Company Name: Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑1 request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: Address: i L,`7 a 51—Arz S Cross Street: MA a Phone No.: Bldg.Permit#: 5 a`I' email: Tax Map District: 1000 Section: �A Block: 4 Lot: I � BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): aRsF- M601- A& Square Footage: 7 Circle All That Apply: Is job ready for inspection?: YES ❑ NO —]Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Undergrouhd Laterals D 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION PERMIT# Address: Switches Outlets. I GFI's Surface Sconces Iv H H s �� I UC Lts Fridge HW POOL Fans Mini Fr. WAD Panel Pump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower AC AH Hood Blower I Service Amps Have Used Sub Amps Have Used Comments KANDEL RESIDENCE DRAWINGLIST 1670 STARS ROAD EAST MARION,NY 11939 A1.00 DRAWING LIST,ABBREVIATIONS, SYMBOLS, &NOTES LUMBER PPR VED AS 7,,,, o'� A2.00 NOTES &ZONING A3.00 BASEMENT PLAN O LEAD CONT>£N7' Er=OAE DA •5 B.R R I O N N Y CE .TIFICATE OF OCCU_PANC 1' NOTE: DO NOT SCALE FROM DRAWINGS FEE BY. jkF27'4-16 OI;DER US89 IIu WA.,, ,�, ER No FY BUILDING DECOMPLY WITH ALL CODES OF ELECTRICAL `J - UP('L ! STEM CANNC PLUMBING XCLEC Z/1:0'OF 1 o LEAD. 631 65-1802 8AM TO 4PM FOR THE NEW YORK STATE&TOWN CODES INSPECTION REQUIRED ALL PLUMBING WASTE !! `k Fo OWING INSPECTIONS: AS REQUIRED AND CO ITIONS OF 1. OUNDATION-TWO REQUIRED OR POURED CONCRETE SOUTHOLDT N ZBA &WATER LINES NEED �- 2. OUGH-FRAMING&PLUMBING SOUTHO OWN PLANNING BOARD TESTING BEFORE COVERING " TAX MAP N0.1000.22.-416 . . 3. INSULATION 00, SOUTH TOWN TRUSTEES - 4. FINAL-CONSTRUCTION MUST ISSUE/REVISION DATE BE COMPLETE FOR C.O. — N.Y$ EC Additional ALL CONSTRUCTION SHALL MEET THE — S OLD HPC DD FILING SET o2.2z2o2s REQUIREMENTS OFTHE CODES OF NEW CHD Certification IVi YO K STATE NOT RESPONSIBLE FOR May Be Required. oo UPDATED FILING SET 04.16.2026 IGNORCONSTRuSYN LS REGULATORY NOTES ABBREVIATIONS DRAWN BY:J.LACHAPELLE D 1. THIS APPLICATION FOR BUILDING PERMIT IS FILED WITH THE A.F.F. ABOVE FINISH FLOOR GWB GYPSUM WALL BOARD CHECKED BY.J.LACHAPELLE LEVEL TOWN OF SOUTHOLD BUILDING DEPARTMENT, IN ALT ALTERNATE NOTE:THIS IS AN 11"x 17"SHEET THIRD FLOOR CONFORMANCE WITH THE TOWN CODE CHAPTER 144, APP. APPLIANCE(S) HM HOLLOW METAL DRAWINGS MAY BE PRINTED NOT TO SCALE AO WINDOW EL. +31'-3° HT HEIGHT \—ELEVATION ABOVE 0'-0" 2. THE CONTROLLING CODE IS THE 2025 BUILDING CODE OF NEW B.O. BY OTHER HW HOT WATER LaChapelle Architecture PLLC O DOOR YORK STATE AND THE 2025 ENERGY CONSERVATION CODE OF P.O.Box 1251 NEW YORK STATE, IN COMBINATION WITH THE TOWN CODE. C/C CENTER TO CENTER MECH. MECHANICAL Mattituck,NY 11952 1 ELEVATION NUMBER CLG CEILING MTL METAL (646)251-5058 jake@lachapellearchitecture.com 1O PARTITION TYPE A6 SHEET NUMBER 3. REFERENCE HEREIN TO 'BC' SHOULD BE CONSTRUED TO MEAN CMU CONCRETE MASONRY UNIT THE APPLICABLE BUILDING CODES OF NEW YORK STATE. CONC CONCRETE PTD PAINTED CONT. CONTINUOUS 4. THIS SINGLE-FAMILY HOME OCCUPANCY CLASSIFICATION IS CONT'D CONTINUED RCP REFLECTED CEILING PLAN �FtED ARC A3 1 DETAIL NUMBER RESIDENTIAL GROUP R-3 UNDER BC CHAPTER 3. \"PCHgp A4 SHEET NUMBER D.H. DOUBLE HUNG O.C. ON CENTER ��` 5. THIS STRUCTURE IS CLASSIFIED AS CONSTRUCTION TYPE V(B) DIM. DIMENSION IY `° �'• (UNPROTECTED WOOD FRAME) UNDER BC TABLES 601 AND 602. DIA. DIAMETER SIM. SIMILAR _ DISC. DISCONTINUOUS S.S. STAINLESS STEEL 6. TO THE BEST OF MY KNOWLEDGE THE WORK PROPOSED DWG DRAWING STL. STEEL (P _ _j HEREIN IS COMPLIANT WITH ALL APPLICABLE LAWS, CODES, 03 O� AND REGULATIONS. ELEC. ELECTRIC TYP. TYPICAL 9TF0F NE�y STAIR DIRECTION LABELS ENG. ENGINEER EQ. EQUAL V.I.F. VERIFY IN FIELD 00 INSPECTIONS EXIST. EXISTING UP DN W/ WITH FL FLOOR WRB WEATHER RESISTIVE BARRIERryre _ SC SMOKE+CARBON MONOXIDE DETECTOR SPECIAL INSPECTIONS MUST BE PROVIDED IN CONFORMANCE WITH THE WD. WOOD "°""""°""�°""" °`"°°"°"`"°�" `°"°""�°nm iHLH VA1116,N'fM°f lift W W R[X CgdfM°t lKf ApELLF M=NIIF=I°i2 PIl=. REQUIREMENTS OF BCNYS 1704&1705. SMOKE AND CO DETECTORS SHALL COMPLY SCOPE O F WORK DRAWING, LIST WITH UL 268,7th ADDITION FINAL ABBREVIATIONS, ®- MATCH LINE OCCUPANCY OR THE GENERAL INTENT OF THE WORK IS TO OBTAIN A CERTIFICATE OF SYMBOLS, & NOTES CENTER LINE USE IS UNLAWFUL OCCUPANCY FOR HABITABLE PORTION OF BASEMENT. NO CHANGE OF USE OR OCCUPANCY IS PROPOSED. SHEET NO: BREAK LINE WITHOUT CERTIFICATE ALOO OFOCCUPANCY SHEET 1 OF 3 GENERAL NOTES GENERAL NOTES GENERAL NOTES KANDEL 1. ALL WORK TO BE PERFORMED BY LICENSED TECHNICIANS TO 7. THE MODIFICATIONS TO THE HOUSE INCLUDED HEREIN MAKE 13. CONTRACTOR MUST COMPLY WITH ALL BUILDING DEPARTMENT RESIDENCE ACCOMPLISH THE WORK AS OUTLINED IN THIS SET OF THIS A LEVEL 2 ALTERATION UNDER EXISTING BUILDING CODE RULES OF OPERATION (SUCH AS HOURS OF ACTIVITY)AND 1670 STARS ROAD DRAWINGS AND AS MAY BE REQUIRED BY THE WORK.ALL (EBC)CHAPTER 6. REQUIREMENTS OF EBC CHAPTER 7 AND 8 INSURANCE REQUIREMENTS. EAST MARION,NY 11939 PLUMBING AND ELECTRICAL WORK SHALL BE CERTIFIED BY APPLY AS A RESULT. CONTRACTOR SHALL CAREFULLY OBSERVE PERSONS LICENSED IN THEIR TRADES,WHO SHALL ARRANGE THE REQUIREMENTS OF SECTION 806. 14, CONTRACTOR SHALL NEITHER INTERRUPT NOR RELOCATE FOR AND OBTAIN INSPECTIONS AND REQUIRED SIGN-OFFS.ALL BUILDING SERVICES WITHOUT WRITTEN REQUEST TO THE OWNER WORK SHALL BE DONE CAREFULLY AND NEATLY, IN A 8. STRUCTURAL OBSERVATION IS NOT REQUIRED UNDER BC 1704.6 AND RECEIPT OF WRITTEN CONSENT. SYSTEMATIC MANNER.ALL WORK PERFORMED BY THE BECAUSE THE BUILDING IS NOT IN THE INDICATED RISK CONTRACTOR SHALL CONFORM TO APPLICABLE CODES, CATEGORIES AND NOT A HIGH-RISE BUILDING. 15. CONTRACTOR SHALL FILE ALL NECESSARY CERTIFICATES WITH THE REGULATIONS,AND INDUSTRY STANDARDS. DEPARTMENT OF BUILDINGS, PAY ALL FEES, OBTAIN ALL PERMITS 9. PROPOSED GWB FINISHES MUST COMPLY WITH BC CHAPTER 8. AND PROVIDE ANY AND ALL BONDS REQUIRED BY ANY CITY 2. IN ADDITION TO THE REQUIREMENTS OF THE APPLICABLE TAPED, PRIMED,AND PAINTED GWB IS ALLOWED UNDER BC 803 AGENCY IN ORDER TO DO THE WORK HEREIN DESCRIBED. BUILDING CODES,ALL WORK MUST CONFORM TO FIRE AND QUALIFIES AS A CLASS-A MATERIAL WITH FLAME SPREAD DEPARTMENT REGULATIONS, UTILITY COMPANY INDEX LESS THAN 25 AND SMOKE-DEVELOPED INDEX BELOW 450. 16. CONTRACTOR SHALL COORDINATE WITH OWNER'S SURVEYOR IF REQUIREMENTS, AND BEST TRADE PRACTICES. THIS EXCEEDS THE REQUIREMENTS OF BC TABLE 803.13 FOR THIS THEIR SERVICES BECOME NECESSARY. TAX MAP NO.1000-22.-a-ss OCCUPANCY R-3. 3. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE 17. PRIOR TO COMMENCING OPERATIONS ON SITE THE # ISSUE/REVISION DATE FIELD PRIOR TO COMMENCING WORK,AND SHALL REPORT ANY 10. INTERCONNECTED SMOKE DETECTOR ALARMS SHALL BE CONTRACTOR SHALL PROVIDE BOTH OWNER AND ARCHITECT .00 FILING SET 02.27.2026 DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS PROVIDED IN CONFORMANCE WITH 'FIRE CODE'1103.8 AND 'ACORD' INSURANCE FORM LISTING THE FOLLOWING PARTIES AS TO THE ARCHITECT. CARBON MONOXIDE DETECTION EQUIPMENT MUST BE PROVIDED ADDITIONALLY INSURED: .00 UPDATED FILING SET 04.16.2026 IN CONFORMANCE WITH 'EXISTING BUILDING CODE' SECTION 804, ANDREW&MELISSA KANDEL 4. CONTRACTOR SHALL TAKE THEIR OWN DIMENSIONS AND FIELD IF NOT ALREADY PRESENT IN THE BUILDING. LACHAPELLE ARCHITECTURE PLLC VERIFY ALL DATA CONTAINED HEREIN. THE DIMENSIONAL DATA THE CONTRACTOR MAY NOT BEGIN SITE OPERATIONS OF ANY CONTAINED IN THIS DRAWING SET ARE FOR INFORMATION 11. CONTRACTOR TO SCHEDULE AND PROVIDE ACCESS REQUIRED KIND UNTIL THE ABOVE IS PROVIDED. DRAWN BY:J.LACHAPELLE ONLY.THE BUILDING IS NOT SQUARE OR PLUMB SO VARIATION FOR ALL INSPECTIONS.WORK MUST REMAIN ACCESSIBLE AND CHECKED BY.J.LACHAPELLE EXISTS IN THE DIMENSIONS OF THE EXISTING BUILDING.AS A EXPOSED UNTIL INSPECTED AND ACCEPTED IN WRITING BY THE 18. LACHAPELLE ARCHITECTURE PLLC HAS BEEN RETAINED BY THE NOTE:THIS IS AN II"x17"SHEET RESULT DIMENSIONS OF NEW CONSTRUCTION MAY VARY FROM INSPECTOR. OWNER TO PERFORM (1) SITE VISIT DURING CONSTRUCTION DRAWINGS MAY BE PRINTED NOT TO SCALE THOSE SHOWN. CONTRACTOR SHALL NOTIFY ARCHITECT OF PHASE ONLY, SOLELY TO IDENTIFY SUBSTANTIAL DEVIATIONS DISCREPANCIES AS THEY ARISE. 12. CONTRACTOR SHALL OBSERVE ALL LOCAL, STATE,AND FEDERAL FROM THE CONTRACT DOCUMENTS. LACHAPELLE ARCHITECTURE LaChapelle Architecture PLLC REGULATIONS CONCERNING THE REMOVAL,TRANSPORT, PLLC IS NOT RESPONSIBLE FOR INTERPRETING THE INTENT OF THE P.O.Box 1251 5. MINOR DETAILS NOT SHOWN OR SPECIFIED, BUT NECESSARY DISPOSAL, AND ALL OTHER ASPECTS OF HAZARDOUS MATERIALS. CONSTRUCTION DOCUMENTS DURING CONSTRUCTION PHASE, Mattituck,NY 11952 FOR PROPER CONSTRUCTION OF ANY PART OF THE WORK THIS INCLUDES BUT IS NOT LIMITED TO REGULATIONS INCLUDING MAKING MODIFICATIONS AS MAY BE NECESSARY (646)251-5058 jake@lachapellearchitecture.com SHALL BE INCLUDED AS IF THEY WERE INDICATED IN THE PROMULGATED BY NY STATE DEPARTMENT OF HEALTH, NY STATE DURING THE CONSTRUCTION PHASE. LACHAPELLE ARCHITECTURE DRAWINGS. DEPARTMENT OF LABOR, NY STATE DEPARTMENT OF IS NO LONGER LIABLE FOR WORK WHERE CHANGES HAVE BEEN ENVIRONMENTAL PROTECTION,AND U.S. ENVIRONMENTAL MADE TO THE WORK SUBSEQUENT TO PREPARATION OF THESE 6. CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES PROTECTION AGENCY,AND U.S.OCCUPATIONAL SAFETY AND DOCUMENTS. WITH REQUIREMENTS OF LOCAL AUTHORITIES AND OWNER. HEALTH ADMINISTRATION. CONTRACTOR SHALL ADDITIONALLY ��RED ARC OBSERVE ALL OBLIGATIONS WITH REGARD TO WORKER TRAINING, 19. THE CONTRACTOR SHALL ENSURE THE STRUCTURAL STABILITY OF 0�`� ��ACHgp�y X ` WORKPLACE SAFETY,AND PROTECTION OF PUBLIC HEALTH AND ALL AREAS OF THE WORK THROUGHOUT OPERATIONS.THE SAFETY. CONTRACTOR SHALL DO SO BY WHATEVER MEANS HE DEEMS ARE NECESSARY, INCLUDING BUT NOT LIMITED TO RETAINING A LICENSED ENGINEER AT THE CONTRACTOR'S EXPENSE TO N OVERSEE AND ADVISE ON THE WORK. A yj, osss3o �0 FOF NE`N ENERGY CODE COMPLIANCE U-FACTOR/R-VALUE FRAME OR BLOCK TO JOISTS iHEsoaawHcaa"iHsmumE"rovsermcEpxo REmamsua vRovE"rc°v ueHUEUE .rxwrecry RE au REcpROLL.ss or wxEm w]HE vm"Ecr rw wxxH tt s vrmpREo u ID ASSEMBLY NOTES QTY ECCNYS PROPOSED MOLD RESISTANT WALL BOARD SUCH AS GOLD BOND XP i aOR �Ho°Rpww°°�' rurHoreE wvd.REsr°R°R�vaokcn, BY NAT.GYPSUM COMPANY omER"a"m10ics�imHom`i`ttH°e"wm 01XEr x"vm°RRise'ifr°ur.0RF° eipNcrrt °Y cciuRvuc ®C W W GIR R 0]6 Ip°HNELLE pgCHIrtCN RE PLLC 3}"MINERAL WOOL INSULATION;"COMFORTBATT"BY ROCKWOOL OR EQUAL(R15) 1 BASEMENT PERIMETER WALLS 1u - 10/13 a 15(PASS)' EXISTING CIP CONCRETE FOUNDATION WALL O 3- MINERAL WOOL BATT @INTERIOR ( ) COLD-ROLLEDW STEEL FRAMING DOTES 2x4 METAL STUDS W/e'GWB COMPOSITE FLOORING a-R10 CONTINUOUS ON INTERIOR OR EXTERIOR, OR RI CAVITY AT INTERIOR SHEET NO: SEE SHEET A3 FOR FENESTRATION VALUES n-CONSTRUCTION OF FINISHED PERIMETER WALLS IN BASEMENT PREDATES 2025 CODE,WHICH WOULD REQUIRE O TYPICAL PARTITION 1O DETAIL A2mOOR19(CAVITY); INSTALLATION MEETS 2020 ECC FOR R15(CAVITY) SCALE: T' = T-0" SHEET 2 OF 3 f REPLACE PLANK FLOORING AT IAA ly®E L a LANDING,FINISH TO MATCH EXISTING 3,�„ T"PLYWOOD SUBFLOOR,BACKSCREW TO STEEL FRAME AND ADHERE w! ES I D E N C E PL-MAX ADHESIVE 1670 STARS ROAD WELDED STEEL FRAME CONSTRUCTED , - ; OF 2 x 2 x HSS TUBE _ " EAST MARION,NY 11939 RISER DIMENSION TO MATCH EXISTING PTD.WOOD TRIM AT SIDES,PTD. ; i BEADBOARD AT UNDERSIDE s" 8 x 6 x L SUPPORT LEDGERS ON 3 SIDES p MODIFY EXISTING TRIMMER JOISTS AS LU LU NECESSARY TO GET 36"MIN.CLEAR ARE c� ABOVE BASEMENT STAIR a N CONFIRM HANDRAIL AT 36" REMOVE FINISHES AT UNDERSIDE OF ABOVE NOSING PER R311.7.8.1; STAIR LANDING AND CONSULTw/ OBSERVE OTHER SECTION O FIRST FLOOR LANDING DETAIL AOR TO FINALIZE DETAILING FOR R311.7 REQUIREMENTS NEW PLATFORM,AND ENSURE 6-8" SCALE: 1" = 1 -0 HEADROOM ABOVE STAIR BELOW BASEMENT STAIR 11 R @ 7p 3-4" TAX MAP N0.1000.22.-4-16 SUMP&PUMP 10 T @ 10" CLEAR \ # ISSUE/REVISION DATE RMOMMON EXIST. HOUSE 20'-3 Z 1 \ .00 FILING SET 02.27.2026 - ' TRAPT I I .00 UPDATED FILING SET 04.16.2026 EXIST.GAS 36" N I I INSTANT I I CD HWH STORAGE _ z BATH j I DRAWN BY:J.LACHAPELLE 12'-0" CHECKED BY:J.LACHAPELLE 44 NOTE:THIS IS AN 11"x 17"SHEET IN 36" DRAWINGS MAY BE PRINTED NOT TO SCALE 8'-33 NOM. EXIST. I 3 'r — 0 LaChapelle Architecture PLLC FURNACE 36" i i P.O.Box 1251 SC I I I Mattituck,NY 11952 W I :I (646)251-5058 jake@lachapellearchitecture.com Cm I I N N MECHANICAL STORAGE REPLACE DOOR AT = I ®I O (UNFINISHED) (UNFINISHED) TOP OF STAIRS W/ T-2„ .0 ARCyi 32"CLEAR I _I \G�� x p GHA/j EXIST, OUTSWING LH UNDE SIDE I I C7 �� �! WELL TANK SOLID CORE WOOD I BEAM DOOR I I ENTERTAINMENT I 36" STAIR HAS 36"CLEA I ROO ABOVE RAILING `N" HELVING THROUGHOUT O EXIST.2 C I I I �` Q333� y AMP ELECTRIC SC =� o I i l TF O F NE SERVICE 1 1 1 1 I itMIN -I I1. T-114" 3'-3Z" c� I I I I \ I -I rxooenn"smumenrasrmxeumaewnsmevnovumo,vc„nreue I I I azvucama+eu 9avwx<mcarxeeaamranwwu,rtuvwnsamo I I °o:e"rea„„mewers.xr°unore.on„eurrons mnreenaoe esevrercvswweuc a"an�rrv"e vuc mn wuwwa nur xm„c usc„er mxe„va"nes vo"m"ea vrmxrn, -I mxrn�e"nr"rs.vm�our`rawa i'riw�""xssr'iiiar'01winniuina""vccuvuc.°Y REATTACH GAS BURNER SWITCH BASEMENT STAIR REPLACE HANDRAIL FACEPLATE 12 R @ 7j" 3 R @ 7" AT 36"ABOVE NOSING I 11T@104" + 2T@943' PERR311,7.8.1; I I \ BASEMENT NOTES: 1"NOSING 1"NOSING OBSERVE OTHER 25'Ni PLAN SECTION R I I \ 1.DOOR SIZES ARE NOMINAL REQUIREMENTS 2.SEE A2 FOR PERIMETER WALL SEE DETAIL 1 THIS PAGE \ \ CONSTRUCTION AND THERMAL CONDUCTANCE REPLACE GUARD AT TO PROVIDE 6'-B"CLEAR STAIR SO THAT GAPS HEADROOM ABOVE STAIR DO NOT EXCEED 4", SHEET NO: SUBJECT TO LANDING PER R311.7.2 SC SMOKE+CARBON MONOXIDE DETECTOR PROJECT EXISTING BASEMENT PLAN EXCEPTIONS IN R312.1.3 SMOKE AND CO DETECTORS SHALL COMPLY NORTH O SCALE: 3/16 = T-0" WITH UL268,7thADDITION A3mOO SHEET 3 OF 3 1 (�J --�-ems,'�A�� �d -�.�r N'���c Dt C✓� � { - ..__ V Opt, a notch exceeds code ..arY limits.reinforce trimmer 'olst wl 2x4 x 48"on both sides;Ledgerl-ok type attachment replace wl 4X4 post . strap at lop and bottom confine footing,if not evident then sawcut and provide 22"x22"x10"concrete footing under the post,reinforced with l2)05 bars in each direction C S K-03 5/22/2026 1670 Stars Road 3 Ni t. • It-PIP 5TA*$ "AD * 0.4"T A, AM O OM Z9�� s�at�l c0 A4Afv*A Combinagon AUarm A-f10WEREj),JUoKLr.CAagoot,WMDMX A WFT H 10-YEAR BATTERY BACXW SMIC0105-AC CAT. 104568311046ft4 HARDWIRE HARDWIRE Combination Alarm WITH tQ-YEAR 0A"ERY SACKUP f 2026 na-Invent ! nlcj 4c ; , t � - I L.,`7 D J Tim 5 # 5 � ice/ SMe� lc� - tom .... .... .... t, t u�; E C E �.a V E JUL - 1 2M Building Department Town of Southold too EC� COMC 2026 Building Department Town of Southold AM 8�) c L- -- I (,-7 U 9 E C E U Building DepIrtment 'Town of SouthrAci SON !M 1 3 s 1 M I s 5 1 JUN 2 5 2026 f �'« rthrai i J61,v p S 202X6 Tovyr� of (p f �* y S x i r .Ai^ r4 - ' r 4 14 �' �", � � .F % •tom! x `4. qr-i� '.- - .x� ' f o r _ IL , 2' 22 23 24 25 26 27 28 29 30 11 12 13 14 115 17 18 9 2(1 i T/ c f J ` lk 1` l' 1 V - Jr w _ s WOO t Y T. t i � a d glow JUN 2 5 2026 13111fding Depar#rpont Town of Southold