Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
52970-Z
�o4'O'of soiIfTyo`o Town of Southold * * P.O. Box 1179 At 53095 Main Rd ueTI h Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 47272 Date: 08/10/2026 THIS CERTIFIES that the building SINGLE FAMILY DWELLING-ALTERATION Location of Property: 11175 Sound Ave Mattituck, NY 11952 SecBlock/Lot: 141.-3-3 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 05/01/2026 Pursuant to which Building Permit No. 52970 and dated: 05/13/2026 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Repairs to an existing single-family dwelling as applied for. The certificate is issued to: Jennifer Michalecko Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: PLUMBERS CERTIFICATION: tho ed igna e ofsoujyo�o TOWN OF SOUTHOLD BUILDING DEPARTMENT N .e SOUTHOLD, NY courm BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52970 Date: 05/13/2026 Permission is hereby granted to: Jennifer Michalecko PO BOX 133 Mattituck, NY 11952 To: construct repairs (due to vehicle crash)to an existing single-family dwelling as applied for. Premises Located at: 11175 Sound Ave, Mattituck, NY 11952 SCTIVI# 141.-3-3 Pursuant to application dated 05/01/2026 and approved by the Building Inspector. To expire on 05/12/2028. Contractors: Required Inspections: Fees: Single Family Dwelling- Alteration $250.00 CO-RESIDENTIAL $100.00 Total $350.00 ---- ------------------------ Building Inspector of SOUTy�� - - -- # # F SOUTH OLD BUILDING y , TOWN O SOU OL BU G DEPT. `ycou 631-765-1802 INSPECTION - . [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE &CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION. [ ]. ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: T`Zvvlo�e GuJ Gv�t�c�au� GoGi vnS. /4" fd�,es It DATE •lam Ao INSPECTOR Of 30UT�°� # TOWN OF SOUTHOLD BUILDING DEPT. cou 631.-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATIOWCAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] _CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: V r . .DATE g INSPECTOR Blue Topaz Electric 1536 Railroad Ave Holbrook, NY 11741 516-852-4036 Subject: Jennifer Michaelecko 11175 Sound Ave Zd26 J Mattituck, NY AUG 1 o g 5 Upon Inspection of electrical wiring due to car accident damage on corner of house, all visible electric is intact and no damage was found. Paul Frade Blue Topaz Electric YIELD INSPECTION REPORT COMMENTS un FOUNDATION (1ST) ------------------------------------- -- FOUNDATION (2ND) "t/1464to(l jl� _! 7e ROUGH FRAMING & ...... PLUMBING azh. WA� 40 - INSULATION PER N. Y. ENERGY CODE .............. .......... ------------ ------ AF\ FLNA-L --------------- ADDITIONAL COMMENTS I .Ha.44-9 0 ........... ----------- ---------- . ----- ........... --- ILL�L- L 419 TOWN OF SOUTHOLD—BUILDING DEPARTMENT g Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971 0959 Telephone (631) 765-1802 Fax(631) 765-9502 https://www.southoldtownny.gov 4 Date Received APPLICATION FOR BUILDING PERMIT r- �. r, For Office Use Only I ;: I t! �U PERMIT NO. � Building Inspector: e r f `. if]. MAY - 1 2026 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date:05/01/26 OWNERS)OF PROPERTY: Name:Jennifer Michalecko SCTM#1000-141-3-3 Project Address:11175 Old Sound Avenue, Mattituck, NY 11952 Phone#: Email:jcmichalecko@gmail.com Mailing Address:11175 Old Sound Avenue, Mattituck, NY 11952 CONTACT PERSON: Name:Brooke Epperson Mailing Address:PO Box 152, Mattituck, NY 11952 Phone#:631 603 9092 Email:bepperson@amparchitect.com DESIGN PROFESSIONAL INFORMATION: Name:Anthony Portillo Mailing Address:PO Box 152, Mattituck, N.Y. 11952 Phone#:631 603 9092 Email:aportillo@amparchitect.com CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION [:]New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: OOther Repair after car ran into house $75,000 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ®No 1 PROPERTY INFORMATION Existing use of property:Single Family Residential Intended use of property:Single Family Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R40 this property? ❑Yes R No IF YES, PROVIDE A COPY. 8 Check Box,After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and.to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name):AMP Architecture ®Authorized Agent ❑Owner Signature of Applicant: Date: `J 1I2fo STATE OF NEW YORK) SS: COUNTY OF ) ��l-XIS �C6�cx 5 being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the Agent ' (Contractor,Agent,Corporate Officer, etc.) -of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this -,- application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of I& , 20, a&Z.4& 2 Z. &?? .9162 Notary Public CHRISTOPHER B BONDARCHIIK PROPERTY OWNER AUTHORIZATION NOTARY PUBLIC So 01B(TF 39944NFW YORI: Registration No I)113(H)niR944 (Where the applicant is not the owner) Qualified in Suffolk C un p k4%Commission Expires Jennifer Michalecko residing at 11175 Old Sound Avenue, I, Mattituck, NY AMP Architecture do hereby authorize to apply on my Kehalf to the Town of Southold Building Department for approval as described herein. 5/1/26 ' wner's Signature Date Jennifer Michalecko Print Owner's Name 2 • • ba I ENGINEERING - ENVIRONMENTAL FIRE Engineering of NY,P.C. Engineering Report Vehicle Impact EFI File No.: 011.14750 February 24, 2026 Insured: Jennifer Michalecko Insured Address: 11175 Sound Avenue Mattituck, NY 11952 Date of Loss: January 19, 2026 Claim No.: 787802707878 Prepared For: Plymouth Rock Attn: Donna Moruzzi 695 Atlantic Avenue Boston, MA 02110 Dmoruzzi@plymouthrock.com Report Authored By: Technical Review By: OF NfW10 Digitally signed *� -40 MpR'�� * by Morra, Steven Date: Fa 1 08881 2026.02.24 SSioNP�'� 16:14:24-05'00' Steven Morra, PE Tyler Renz Forensic Engineer Technical Reviewer PE Expires:October 31, 2026 EFI Global Engineering of New York, P.C. COA Number:023223, Exp Date:07/2028 07094 ` efi global Engineering of NY,P.C. ASSIGNMENT The assignment was received by EFI Global Engineering of NY,P.C.(EFI)on February 12,2026,from Donna Moruzzi with Plymouth Rock. The scope of this assignment was to determine the extent of damage caused by a vehicle impact that was reported on January 19,2026. EFI has performed an engineering assessment at the subject property located at the above loss location. EFI's findings, analysis, and conclusions, based on information available to-date, are included herein. METHODOLOGY The information collected in relation to this assignment was analyzed and conclusions were developed based this author's engineering training, knowledge, experience,as well as inductive and deductive reasoning. The procedures followed included: 1. Upon receipt of the assignment, a site examination was conducted on February 16, 2026.Steven Morra, PE (EFI) and Jennifer Michalecko(the insured)were present at that time. 2. EFI performed interviews with:Jennifer Michalekco,the insured. 3. EFI reviewed the following provided documents: a. A Photo Sheet dated January 20, 2026,from ServiceMaster by American Restoration Services 4. EFI researched the following: a. Aerial Imagery via Nearmapl 5. A verbal update was provided to Donna Moruzzi with Plymouth Rock on February 18,2026. 6. This written report was authored at the request of Donna Moruzzi. BACKGROUND The following information was gathered during the site visit and through an interview of the insured: • The house was purchased by her parents in 1952. • The interior was painted at least 6 years ago. • The vehicle crashed into the southwest corner of the house.The driver attempted to reverse the vehicle out but was unsuccessful. • The south entrance door was replaced the day prior to the DoL, it was the incorrect door and needs to be returned and replaced. 1 Nearmap, "https://www.nearmap.com/,accessed February 20,2026. Insured:Jennifer Michalecko 2 EFI File#:011.14750 Claim#:787802707878 efi global FngineennR of NV,�� BUILDING SYSTEM DESCRIPTION The structure was a single-family dwelling constructed of light wood frame with cross gable roof slopes supported on a basement type foundation. The roof was covered with laminate asphalt shingles. The exterior walls were clad with wood shakes (Photos 1 - 4). For this report, the front is considered to face south towards Old Sound Avenue. 1 *01r. 1 N L , , ti a , ' Direction of 3• �j r t n,�r'�tt ' Figure 1:Aerial View—Courtesy of Nearmap—October 1,2025 SITE OBSERVATIONS Observations were limited to visual examinations and measurements of accessible portions of the subject property. Removal of finish materials, qualitative testing, excavation, or other work not specifically described herein was not conducted. Observations were photographed to document distress and relevant conditions at the subject property on the date of the site visit that were related to the scope of this assignment. Not all damage or distress that may be present was necessarily observed or photographed; however,the selected photographs provide an indication of their types, severity, and distribution. The photographs may also document unusual or contributing conditions that may exist. A sampling of photographs captured to document findings and observations are attached to this report.Additional photographs captured are available upon request. During this investigation,the following observations were made: EXTERIOR SITE OBSERVATIONS: • The portico was supported by temporary 2x4 studs. The bottom of the portico was 8-feet 6-inches tall. Two(2)8-inch diameter columns originally supported the portico. One post was observed to be missing, Insured:Jennifer Michalecko 3 EFI File#:011.14750 Claim#:787802707878 ,sue, efi global Engineering of NY,P.C. while the remaining post was displaced. The top of the remaining post was leaning north toward the entrance of the dwelling. See Photo 5. • Sharp cracking was observed between the top of moulding and bottom of portico interface. Two wood shakes were visibly damaged, displaying sharp vertical cracks through the full body of the shake. The storm door and entrance door were operable at the time of visit.See Photo 6. • A tarp was covering an approximate 3-foot section of westward facing wall and approximate 3-foot section of southward facing bump out.The tarp was covering a window opening on the southward facing wall.See Photo 7. • Seven (7) wood shakes were observed to be chipped at the southmost edges along a westward facing wall. See Photo 8. • The northwest corner of the portico was detached from the southward facing entrance wall. A gap between the top of entrance moulding and the bottom of the portico revealed unpainted plank. See Photo 9. • Two (2) casement windows on the west bump out wall were not operable.The lower right-hand corner and upper left-hand corner of each window were scraping against the opening trim. See Photo 10. • The casement window on the north wall of the bump was not operable.The window was scraping against the upper left-hand corner of the window trim.See Photo 11. INTERIOR SITE OBSERVATIONS • The south wall of the bump out was leaning/bowed to the north.A double 3x4 post was cracked and bent toward the north. Drywall on both the north and east facing interior walls had broken into pieces, portions were still hanging on the wall studs, and the remaining pieces were observed on the floor. See Photo 12. • A crack was observed stemming from the south entrance and spanned to the southwest corner of the room. The drywall below the crack was 12-inches wide, detached and portions were missing. Approximately 2-feet of a 6x4 post in the southwest corner was missing. A horizontal crack along the drywall was observed,starting from the top of the missing section of post and spanning the whole width of drywall.The studs behind the drywall were fractured and bowed toward the east. See Photos 13-14. • On the south wall of the bump, a casement window's pane had shattered. The moulding around the opening was missing and the drywall surrounding the window was cracked.The baseboard heating was displaced and no longer connected to the supply pipe.See Photos 15-16. • Sharp hairline cracks were observed in the upper right-hand,corners of the windows in the northwest corner of the bump out.The moulding at the top of the walls had hairline cracks along the ceiling interface and wall interface. See Photo 17. • A crack spanned outwards from the southeast corner of the bump out to approximately 60-inches into the interior living space.The cracks maximum gap was approximately 1/16-inches.See Photo 18. • The moulding at the top of the walls north of the bump out had hairline cracks along the ceiling interface and wall interface. The doorway between the damaged living space and the kitchen had a crack in the upper-left hand corner.The cracks had sharp edges and were continuous, starting at the top of walls in the bump area.See Photo 19. • On the second floor,above the area of impact,a window in the south wall had a crack diagonally spanning from the upper right-hand corner to the bottom of the ceiling moulding. See Photo 20. Insured:Jennifer Michalecko 4 EFI File#:011.14750 Claim#:787802707878 efi global Engineering of NY,P.C. • A hairline crack was observed in the upper right-hand corner of the second-floor window at the west exterior wall. The crack spanned from the corner of the window to the bottom of the ceiling trim. See Photo 21. DISCUSSION AND ANALYSIS As stated above,the scope of this assignment was to determine the extent of structural damage caused by vehicle impact. GENERAL INFORMATION REGARDING IMPACT Structural damage caused by vehicle impact can vary in magnitude from damage that is localized at the point of impact to damage that is widespread,globally impacting the structure.The magnitude of the structural damage correlates, in part, with the force of the impact, type of structure, and the load path through which the impact force travels through the structure. Global damage from a vehicle impact may result in out-of-plumb or racked framing components and/or walls (members/walls that are displaced laterally)throughout the structure and/or diagonal cracking at wall openings such as at the top corners of doors and windows. Finished wall cracks can occur as a result of the sudden impact. The elasticity of building components varies, and therefore, certain materials will bend due to the impact and then return to the original position without permanent deformation or damage,while other materials that are brittle or less elastic will bend and permanently deflect. Gypsum and plaster materials are more brittle or less elastic than wood framing and therefore will fracture or crack as a result of the wood framed building's response to the impact. VEHICLE IMPACT—EXTERIOR The dwelling was examined after a vehicle impacted the house from the southwest. PORTICO An 8-in diameter portico support post was missing. While one post remained,the remaining post was leaning north.A post leaning north is consistent with an impact force in the reported direction of the vehicle at impact. In photo 9,the portico was noted to have a gap between the north edge and the south face of the entrance wall.Above the south entrance to the door, horizontal sharp cracks were observed between the top of moulding and the bottom plank finish of the portico.The interface showed the moulding attached to the face of wall while detached from the ceiling of the portico.The exposed plank ceiling of the portico was not painted. This indicated that the wall was pushed north by the vehicle,separating the portico connection from the wall. Sharp cracks were also observed in two wood shakes in the same area. Sharp cracks indicate the cracks were recent. AREA OF IMPACT EFI was limited to a visual inspection of the exterior due to a grey tarp covering the area of impact.At the west edge of the tarp seven (7)wood shakes were observed that were consistent with damage from a vehicle impact.The interior side of the impact was inspected and discussed below. BUMP OUT WINDOWS EFI tested the operation of windows and doors surrounding the area of impact. EFI found that the south entrance door was still operable and did not scrape the encompassing door jambs. When attempting to open the casement windows on the west and north face of the bump out,they would not open properly. Additional force was needed for the window to clear the window opening.The windows on the west side were visibly scraping at the upper left and bottom right corners.Scraping at these corners indicated the rough openings were racked toward the north.The window on the north side of the bump out also scraped at the upper left- Insured:Jennifer Michalecko 5 EFI File#:011.14750 Claim M 787802707878 s ; efi global Engineering of NY,P.C. hand corner indicating the it had experienced rotation in plane to the east.A force from the opposite direction would cause the rotation of these windows.This is consistent with an impact force in the direction of the southwest. VEHICLE IMPACT—INTERIOR AREA OF IMPACT The interior of the dwelling was assessed for wall cracks in the gypsum finishes and cracks in wood framing members. The southwest corner of the entrance area was exposed. Approximately 2-feet of a 6x4 post was missing. Cracked gypsum along the perpendicular wall at the entrance covered studs behind. These studs were bent to the east. The north wall had a double 3x4 post that was cracked and bent to the north. While joist direction could not be verified, they were likely running north to south due to the shorter joist span. The wall framing at the area of impact would be structural.A window opening framed into the north wall was cracked and misshapen from the vehicle impact. FIRST FLOOR-BUMP OUT The west bump out wall to the exterior had cracks in the drywall. These cracks were sharp, indicating they had formed recently.The cracks were in the same corners as the window misalignment at the exterior side (photos 10&11). The top of the moulding to ceiling interface along this west wall,the north wall and the adjacent interior north wall (photo 19) also exhibited sharp fresh cracks consistent with the vehicle impact direction. SECOND FLOOR—BEDROOM ABOVE AREA OF IMPACT AND BUMPOUT On the second floor, drywall cracks were observed stemming from the corners of the two windows. One along the south wall above the area of impact and the second on the west wall above the northwest corner of the bump out.These cracks were cosmetic and did not indicate an alteration in the structural integrity of the second floor. CONCLUSIONS The analysis of available evidence related to this assignment supports the following opinions: 1. The reported vehicle impact resulted in structural damage to the subject residence that included the following: a. The displacement of two 8-in portico columns. b. The edge of the portico was detached from the south facing entrance wall. c. The four(4)window frames at the bump out section were racked. d. The south 3-foot-wide bump out wall and the 3-foot west entrance wall framing. 2. The reported vehicle impact resulted in non-structural damage to the subject residence that included the following: a. The cracked drywall on the interior side of the south 3-foot-wide bump out wall and the 3-foot west entrance wall framing. b. The 12-inch-wide section of drywall below the crack at the interior of the south entrance door. c. Cracks below and above the corners of the west and north bump out windows. d. A 60-inch crack in the drywall ceiling at the first floor stemming from the area of impact. Insured:Jennifer Michalecko 6 EFI File#:011.14750 Claim#:787802707878 efi global Engineering of NY,P.C. e. Hairline cracks between the top of the wall moulding and bottom of ceiling interface along the interior of the first-floor bump out. f. Two(2)diagonal cracks at the upper right-hand corners of two windows at the second floor above the area of impact. g. Nine (9)visibly damaged wood shakes. EFI appreciates this opportunity to provide consulting services related to this matter. Please contact us should any questions arise concerning this report, or if we may be of further assistance. ADDITIONAL WORK AND INFORMATION REQUESTED No additional work by EFI is recommended at this time. If any further information becomes available, please forward that to EFI for additional analysis. APPENDICES The following appendices are attached to this report and should be considered as part of the report: • Appendix A—Photographs LIMITATIONS The information presented in this report addresses the limited scope of work related to the evaluation of this assignment. The opinions presented in this report have been made to a reasonable degree of scientific and engineering certainty based upon the information available at the time this report was authored.This report only describes the conditions present at the time of EFI's examination and is only based upon the observations made. This analysis is not intended to fully delineate or document every defect or deficiency throughout the subject property.Should additional information which relates to this evaluation become known, EFI reserves the right to alter the opinions contained in this report, as necessary. This report is furnished as privileged and confidential to the addressee. Release to any other company, concern, or individual is solely the responsibility of the addressee.Any verbal statements made before,during,or afterthe course of the assignment were made as a courtesy only and are not considered a part of this report. Insured:Jennifer Michalecko 7 EFI File#:011.14750 Claim#:787802707878 s,•'.; efi global Engineering of NY,P.C. APPENDIX A PHOTOGRAPHS Insured:Jennifer Michalecko EFI File#:011.14750 Claim#:787802707878 (0) 21. efi global Photographs Photo No. 1: South Elevation. �l w PhotoElevation. Date:Insured:Jennifer Michalecko Site Visit Global efi • • b. Photographs 6 i . . Elevation. lot Photo No. Date:Insured:Jennifer Michalecko Site Visit GlobalEFI 00), efi global - Photographs { ! R. N c _ 1 Photo No.5: The portico was supported by temporary 2x4 studs.Two(2)8-inch diameter posts originally supported the portico.One post was observed to be missing.The top of the remaining post was leaning north toward the entrance of the dwelling. AL Photo No. 6: Sharp cracking was observed between the top of molding and bottom of portico interface. Two wood shakes were visibly damaged,displaying sharp vertical cracks through the full body of the shake. Insured:Jennifer Michalecko Site Visit Date:February 16,2026 EFI Global File#:011.14750 CI� of i global Photographs F t ' a Photo No.7: A tarp was observed covering an approximate 3-foot section of westward facing wall and approximate 3-foot section of southward facing wall F t I 1 Photo No.8: Seven (7)wood shakes were observed to be chipped at the southmost edges along a westward facing wall. Insured:Jennifer Michalecko Site Visit Date:February 16,2026 EFI Global File Jl:011.14750 Coo) efi global Photographs y .� S. i Photo No. 9: The northwest corner of the portico was detached from the southward facing entrance wall. N i Photo No. 10: Two(2)casement windows on the west bump out wall were not operable.The lower right- hand corner and upper left-hand corner of each window were scraping against the opening trim. Insured:Jennifer Michalecko Site Visit Date:February 16, 2026 EFI Global File tt:011.14750 efi global Photographs �w A � y If Photo No. 11: The casement window on the north wall of the bump was not operable.The window was scraping against the upper left-hand corner of the window trim. �h 01 1�p r Photo No. 12: The south wall of the bump out was bowing north.A double 30 post was cracked and bent toward the north. Insured:Jennifer Michalecko Site Visit Date:February 16, 2026 fFl Global File J#:011.14750 efi global Photographs ,I Photo No. 13: A crack was observed stemming from the south entrance and spanned to the southwest corner of the room. w Photo No. 14: Approximately 2-feet of a 6x4 post in the southwest corner was missing. A horizontal crack along the drywall was observed,starting from the top of the missing section of post and spanning the whole width of drywall. Insured:Jennifer Michalecko Site Visit Date:February 16,2026 EFI Global File#:011.14750 of i global Photographs Photo No. 15: On the south wall of the bump,a casement window's pane had shattered.The molding around the opening was missing and the drywall surrounding the window was cracked. I Photo No. 16: The baseboard heating was mangled and no longer connected to the supply pipe. Insured:Jennifer Michalecko Site Visit Date:February 16,2026 EFI Global File it:011.14750 (0) of i global Photographs Photo No. 17: Sharp hairline cracks were observed in the upper right-hand corners of the windows in the northwest corner of the bump out.The molding at the top of the walls had hairline cracks along the ceiling interface and wall interface. Photo 19 Photo No. 18: A crack spanned outwards from the southeast corner of the bump out to approximately 60- inches into the interior living space. Insured:Jennifer Michalecko Site Visit Date:February 16,2026 EFI Global File#:011.14750 efi global Photographs Photo No. 19: The molding at the top of the walls north of the bump out had hairline cracks along the ceiling interface and wall interface.The doorway between the damaged living space and the kitchen has a crack in the upper-left hand corner. r :., 'C yr: 1 r Photo No. 20: On the second floor, above the area of impact a window in the south wall had a crack diagonally spanning from the upper right-hand corner to the bottom of ceiling molding. Insured:Jennifer Michalecko Site Visit Date:February 16,2026 EFI Global File#:011.14750 ��� of i global Photographs } 3 Photo No.21: A hairline crack was observed in the upper right-hand corner of the second-floor window at the west exterior wall.The crack spanned from the corner of the window to the bottom of the ceiling trim. Insured:Jennifer Michalecko Site Visit Date:February 16,2026 EFI Global File#:011.14750 �1 . t. _ � ��'* . . '. d i,,. ��°� �;�.; o � ,� � � ac � s ._ ._ , .�,, Q ���� rTc �J-,z T V F � 4 � h � c I . i I : `i • I� or I s 1 I` f H3293aMA - i 1 • rl �Q D EPA Q \kjV LU LU J � APP OV D AS N0110 C DATE:` �• B.P.# J;m FAOE 0 O FEE e BY: Y�' ,'�" ,��:,;;'c- " A ; „ a <' . Y KE" c9 NOTIFY BUILDING DEPARTMENT AT - `° "" •r - co 0�0 -765 2 8AM TO 4PM FOR THE - .�, " + 631 -180 FOLLOWING INSPECTIONS: .�►�' �' a 1 ,►, _, _, , 41•t .4.r .c •, ky � FOUNDATION-Thin��^ "� h -OO .00 PROJECT LOCATION &SCOPE m — k �i ay,J�!• w +r`� t�,.... "e�l..a;t•.�3 O 0 4--� 1. Y ? . a\ 3" '.. 4 M. •ti �`` w` i h' *. t�yl �,k 1 .. ,� ANC O FOR POURED( t��vCRF r X 0 CD 2. ROUGH-FRAM;NG t�F;-_ - , #p � ,,.�# �• ,., � � � •ti�',+��.r•�' , - 3. INSULATION �. ., • �.`;,�a ,�„ �., :` ..�., ' ;` �.••"h��y t.,; `,'' UCTION MUST 4. FINAL-CONSTR ' 1 :� • • _ GENERAL NOTES BE COMPLETE FOR C.O. she '" `�' "� !'" w — w "1 • ae• �q `•.7~' k A/ �� '�*� "fie ♦f • 7rn; �. r �� ��•^� lF ••+�+ t 002 .00 ALL CONSTRUCTION SHALL MEET THE '.� � - 't"� • � �t� "'�w ENERGY TABLE CD CODES OF NEW ��.., ",.,. :��• REQUIREMENT , ��. . e -+� .�,;a ,, s"+ `• _,'; ; '" "� « T RESPONSIBLE FOR _ , . �,,, ;; ,.+ ;�" ;;+� `':« , " $, �- �.;a`-• r.:.«: STRUCTURAL DESIGN CHARTS YORK STATE. NO 1•.* � z,: .•;�.. .c• -• F, � �'+� •""..�_"*"-. �•�� �' � DESIGN OR CONSTRUCTON ERRORS y 6ti'•►a .+ .,�'"!, '>�'i✓'-ar, "1 'S. ✓Its' �'i',,• + ��+"' „ �,. '1' `# "' �":'+'.,, ~�° +z `^w 'y..��-�' ♦ "aCCC� [r��er,pt, ►':r ,;;� ��%��� ��: �"����;.: �,.�� � ..•,-, �"',�L"`�,�,a �'" -^�i"�''„ . ���:t•`�:: `� :�'"�z' ,`i��;�" 4g'� .00 HOEDOWN, ANCHOR BOLT, w� r�l r a •s �.�.�f°7�'+ery*;"+1. * ' ''f ..w""'"'�.,.s"-�"��1 •, e iaf•'Y''. t.'rt• ,� �.•,+{' X x�""•`` t,+wiuyh,�Gx^•'R 1lc:f„ « `+,,,I -_ _ ;.fi^�S[••. 1 + �f ,I�r. ;.w.- , .'' STRAPPING, & NAILING DETAILS r ' w- �, _ ! ; � � .f # •'r�'''�'3`P' .. Wei" FASTENING SCHEDULE •— COMPLY WITH ALL C DE+� OF �• '� �j�_ '- —QQ� QQ FRAMING GRAPHICS NEW YORK STATE &T •te i.\' 4 « r �. �. � i` �� r�� '" l 1?yyMs,t �� h a .�J IM- � .. �.., } .�`�' * s,« o r �`. BEAM CONNECTION PATTERNS • AS REQUIRED AND C NDITIONS OF '" ` SOUTHO TOiJN ZBA _ , �,+ tA . . ' �' ,� • .'.� : . ,; *x' •.� ' ,r �'%'�` '- ����rr1ww,r`°` ` h , :::r-". P /� � .-"'" • ;.�:.r FIREBLOCKING DETAILS " 3ar r�Stw� S r a• T1";1 x#,.r.a �. "«�; A til9 ,y y t �.. a..h \ , ✓+".N ,A awl ✓y+� `' l SO LD TOIdN PLANNING BOARD • Q Q Q P �„ t <w4�`a �*7 , 'rzr"' ' : ,<;-,_` ;« ,. „ -` ; , , I,- . - ,� c� ROPOSED PLANS SOOLDTOWNTRUTEES ? *, -,.,. , �(�e�"';'` i'; � �'1°f`#.+." ,,,,•,,,�''i y-,'" s,'�'�'( 1„ 0, i��"s,r1!e�'r+`� ." n' s, `j • ~ � �.?� ''+ � .'i1 � ��iL :.�e�'». A, � �. "e`9 .S,DEC .� � �` ,~_..•. .� �. •�, . — UTHOLDHPC LOCATION MA � SCHD SCALE: NT5 -2O � .00 EXTERIOR ELEVATIONS BUILDING SECTION 0 OCCUPAN 0 DESIGN DETAILS ��L�-�����UL FRO�E�T USE I U v _ 11 k0� I C T' I�� � • - STRIUCTURAL $ COSMETIC REPAIRS TO PORTION OF EX I STI NO OF OC� U ARM HOME AS THE RESULT OF \/EH I CLE I MPAGT. - ALL WORK TO BE DONE I N-KIND. - PRO)P. AREA OF EXTERIOR N4LL REPAIR @ IMPACT SITE, RECONNECTION OF EX I STI NO PORCH ROOF TO EX I STI NO HOME NC.;LUD I NO (2) NEW 8"D I AM. COLUMNS, REPLACEMENT OF (4) ELECTRICAL. NI INDONS ON FIRST FLOOR, REPAIRS TO EX I STI NO INSPECTION REQUIRED 5ASEE30ARD RADIATORS AS NEEDED, COSMETICC, REPAIRS TO AFFECTED EXTERIOR I NCLUD I NO S I D I NO � TRIM, AS NELL AS COSMETIC REPAIRS TO AFFECTEID INTERIOR IDRYNALL AND TRIM. - EXTENT OF STRUCTURAL DAM,AOE DETAILED IN ENO I NEER I NO REPORT E3"r STE\/EN MORRA, IDATED 02/24/26. Provide windbne debris erisor protection forF glazing on buildings as per Ny5 Code. W 0 PROJECT / ZONING DATA All exterior lighting TAX MAP # 1000-141-3-3 installed,replaced or repaired shall conform ZONING DISTRICT R-4o W a P to Chapter 172 LOT AREA 0.4 ACRES of the Town Code FEMA FLOOD ZONE X PROJECT: MICHALECKO REPAIRS 11175 OLD SOUND AVE. MATTITUCK, NY 11952 DRAWING TITLE: PROJECT LOCATION & SCOPE PAGE: G-00loOO DATE: 04/29/26 1 OF 6 P� a d NOTES $ SPEC I F I GATI ONS CARPENTRY WOOD FRAMING MATERIAL STANDARDS &LASS WINDOWS AND DOORS A55RE Y I AT I O NS IT 15 THE CONTRACTOR'S RESPONSIBILITY TO KEEP THIS CONSTRUCTION DCOCUMENT BINDER I. ALL LUMBER SHALL BE DOUOLA5 FIR LARCH #2 $ BETTER (Fb = 515) UNLESS THE PROVISIONS OF THIS STANDARD ARE NOT INTENDED TO PREVENT THE USE I. ALL 6LA55 TO BE INSULATED LOW-E, UNLE55 OTHERWISE SPECIFIED. TOGETHER AT ALL TIMES. IT 15 ALSO THE CONTRACTOR'S RESPONSIBILITYr TO READ ALL NOTES, OTHERWISE NOTED. OF ANY MATERIAL OR METHOD OF CONSTRUCTION NOT SPECIFICALLY BD. BOARD INSUL. INSULATION 5PECIFICATION5,AND BE FAMILIARIZED WITH THE PLANS PRIOR T(O WORK PRE50RIBF-D HEREIN. WHEN IT CAN BE 5HOWN, AND THE AUTHORITY HAVING 2. 6LA55 DOORS AND WINDOI^�S SHALL NOT BE INSTALLED UNTIL PROPER 2. ALL LUMBER IN CRAWL SPACES TO BE IS ABOVE SCRATCH GOAT. MAINTAIN JURISDICTION FINDS BY EXPERIENCE, MODELING, OR TESTING BY AN APPROVED CLEARANCES ARE PROVIDED. BFE BASE FLOOD ELEVATION INT. INTERIOR Q 6" MIN. FOUNDATION EXPOSURE. AGENCY, THAT A PRODUCT OR PROCEDURE PROVIDES EQUIVALENT OR GREATER STRUCTURAL SAFETY OR DURABILITY, SUCH PRODUCT OR PROCEDURE 3. ALL SLIDING &LA55 DOORSi,5KYL16HT5, AND ANY 6LA55 UNIT INSTALLED GENERAL BLDO. BUILDING K KIPS (1000 LB5) I. NO WORK TO START UNTIL APPROVED FLANS ARE OBTAINEID FROM THE 5. SILLS TO BE P.T. AND SECURELY FLASHED WITH A TERMITE SHIELD, ALSO SHALL BE DEEMED TO CONFORM TO THE REQUIREMENTS OF THIS DOCUMENT WITHIN 15" OF FINISHED FLOOR:SHALL BE OF INSULATED TEMPERED CLASS, LJ APPLICABLE BUILDING DEPARTMENT. PROVIDE BILL SEAL/INSULATION. SIZE OF SILL TO BE (2) 2"xb", UNLE55 (1) 2"xb" (THIS DOCUMENT 15 TO MEAN A REFERENCE TO THE CURRENT AMERIGAN WOOD UNLESS OTHERWISE NOTED. BM BEAM MANU. SPEG.'s MANUFACTURER'S SPEGIFIGATIONSLu 15 NECESSARY TO MATCH FLOOR HEICHT5 WITH THE EXISTING STRUCTURE. COUNCIL'S WOOD FRAME CONSTRUCTION MANUAL AND THI5 PS FORMAT, AS J BOTTOM OF B.C. X. MAXIMUM WORKMAN LIKE MANNER. 'S m 2. ALL CONSTRUCTION SHALL BE PERFORMED IN A APPLICABLE AS A DERIVED WORK). 4. ALL 6LA55 UNITS SHALL BE: INSTALLED IN STRICT ACCORDANCE WITH ALL DIMENSIONS, CONDITIONS, AND APPLICABLE INFORMATION OF EXISTING 4. AT FLUSH FRAMING USE I6 6A6E METAL JOISTS HANGERS BY "TECO" OR MANUFACTURER SPEC IFIGATIcONS. . Q a..r LN STRUCTURE/SITE SHALL BE FIELD VERIFIED BY GENERAL CONITRAGTOR. EQUAL. I. IDENTIFICATION: ALL SOLID-SAWN LUMBER, GLUED LAMINATED TIMBER, BOT. BOTTOM MEGH. MECHANICAL CY_ •p PREFABRICATED WOOD I-JOISTS, STRUCTURAL COMPOSITE LUMBER, 5. ALL WINDOWS TO BE GAULKIED AND SEALED AS PER NEW PORK STATE 3. ALL WORK SHALL CONFORM TO NATIONAL, STATE, AND LOCAL GORES 5. MINIMUM, DOUBLE HEADERS AND TRIMMERS AROUND ALL OPENIN05 IN PREFABRICATED WOOD TRUSSES, GYPSUM, HARDBOARD, AND STRUCTURAL ENERGY CONSERVATION CON57RUCTION CODE. M FLOORS, ROOFS, AND WALLS. PANELS, SHALL CONFORM TO THE APPLICABLE STANDARDS OR GRADING B.O.W. BOTTOM OF WALL MIN. MINIMUM _ AND AUTHORITIES HAVING JURISDICTION. RULES SPECIFIED IN I.I THROUGH I.6. 6. PROVIDE FLASHING PANS UMIDER ALL 5LIDIN6 6LA55 DOOR5, WINDOWS, OR _ O 6. DOUBLE ALL JOISTS UNDER PARALLEL PARTITIONS, POSTS, AND BATH TUBS, ANY OTHER TYPE OF 6LA55 UNIT WHEN WITHIN 6" OF AN EXTERIOR SURFACE. G.J. CEILING JOIST NAVD&5 NORTH AMERIGAN VERTICAL DATUM OF I�i88 � } 4. ALL UNNOTED OR NON-VISIBLE EASEMENTS ARE THE RESPONSIBILITY z U.O.N. I.I. LUMBER: ALL WOOD MEMBERS USED FOR LOAD-BEARING PURPOSES, p C (\J 0 OF THE OWNER/BUILDER INCLUDING END-JOINTED AND EDGE-GLUED LUMBER, SHALL BE IDENTIFIED 7. ALL EXTERIOR DOORS ARE TO BE WEATHERED STRIPPED AND PROVIDE ALL COL. COLUMN NYC BG NEW YORK CITY BUILDING CODE 7. ALL BEAMS, GIRDERS, ETC. TO HAVE MIN. OF 3-1/2" BEARING BY THE 6RADEMARK OF A LUMBER GRADING OR INSPECTION AGENCY SCREENS AND HARDWARE NEO:E55ARY FOR PROPER FUNCTION OF SUCH UNITS, a •� � U � 3. ANY OMISSIONS OR DISCREPANCIES OF: PLANS AND/OR J015 CONDITIONS WHICH PARTICIPATES IN AN ACCREDITATION PROGRAM, SUCH AS THE CONT. CONTINUOUS O.G. ON CENTER � SHALL BE CLARIFIED WITH THE ARGHITEOVENGINEER BEFORE: PROCEEDING 8. MIN. HEADER TO BE (2) 2"xl0" UNLE55 OTHERWISE NOTED. AMERIGAN LUMBER STANDARDS COMMITTEE OR EQUIVALENT. THE 5. ALL 6LA55 IS TO BE FREE IOF SCRATCHES AND IMPERFECTIONS. 6LA55 p p N WITH THE WORK. 6RADEMARK SHALL INCLUDE AN EASILY DISTINGUISHABLE MARK OR SHOULD BE GUARANTEED BY T-HE MANUFACTURER FOR A PERIOD OF 5 YEARS. DBL. DOUBLE COO. OCCUPANCY p O m •� Cfl a. ALL WOOD SILLS AND WOOD IN CONTACT WITH MASONRY/CONCRETE TO BE IN515NIA OF THE GRADING AGENCY WHICH COMPLIES WITH THE 6. NO DEVIATIONS OR CHANCES TO THE STRUCTURAL SYSTEM( SHALL BE MADE PT REQUIREMENTS OF U.S. DEPARTMENT OF COMMERCE P520-9q. Cl. ALL WINDOWS TO BE ANDER:5EN. IF CONTRACTOR 15 TO SUBSTITUTE WITH DFE DESIGN FLOOD ELEVATION O.H. OVERHANG � CV p ca UNLESS APPROVED BY THE ARGHITEGT/ENGINEER. ANOTHER WINDOW MANUFACTURER, IT 15 THE RESPONSIBILITY OF THE Q d 10. ALL EXTERIOR 5HEATHIN6 SHALL BE NAILED AS PER FA5TENIN& SCHEDULE 1.2. GLUED LAMINATED TIMBERS: GLUED LAMINATED TIMBERS SHALL MEET CONTRACTOR TO VERIFY THAIT THE CHARACTERISTICS OF THE WINDOW MATCH DIM. DIMENSION PBFE PRELIMINARY BASE FLOOD ELEVATION 7. CONTRACTOR TO VERIFY DIMENSIONS OF FOUNDATION WITH FLOOR PLANS ON PAGE 6-005. GENERALLY, SHEATHING 15 OF 1/2" THICKNESS ON WALLS AND THE PROVISIONS OF ANSI/ALTO A I CIO.I STRUCTURAL GLUED LAMINATED THE CHARACTERISTICS OF THE'_ ANDERSEN WINDOW SPECIFIED. THE BEFORE THE START OF FRAMING ROOF AND 15 OF GDX GRADE, UNLESS OTHERWISE NOTED. SEE FLOOR PLANS TIMBERS. CHARACTERISTICS ARE AS FO)LLOW5, BUT NOT LIMITED TO: DESIGN PRESSURE, D.J. DECK JOISTS P. GONG. POURED CONCRETE FOR ADDITIONAL NAILING OR DIFFERENT NAILING REQUIREMENTS WHEN ROUGH OPENING, U-FACTOR, LIc6HT AREA, VENT AREA, AND EGRESS 5. DRY WELLS AS REQUIRED BY STATE AND LOCAL GORES. APPLICABLE. 1.3. PREFABRICATED WOOD I-JOISTS: ASSEMBLIES USING PREFABRICATED REQUIREMENTS. EA. EACH PL. PLATE ^ ` WOOD I-JOISTS SHALL MEET THE PROVISIONS OF ASTM D5055 W Q. DO NOT SCALE DRAWINGS, WRITTEN DIMENSIONS TAKE PREcGEDENGE 11. SUB FLOORING, GENERALLY, TO BE OF 5/4" THICKNESS AND OF GDX GRADE. STANDARD SPECIFICATION FOR ESTABLISHING AND MONITORING 10. WINDOWS IN TUB/SHOWER ENCLOSURES AND WITHIN STAIRWAYS SHALL BE ELEV. ELEVATION PLYWD. PLYWOOD 10. OWNER/BUILDER ARE RESPONSIBLE FOR ALL INSPEGTIONS�, APPROVALS, NAILING AS PER FASTENING SCHEDULE ON PAGE 0-005 AND GLUED, U.O.N. STRUCTURAL CAPACITIES OF PREFABRICATED WOOD I-JOISTS, THIS TEMPERED 6LA55. CERTIFICATES, CERT. OF OCCUPANCY OR COMPLETION AND U1.L. APPROVAL DOCUMENT, THE C70VERNINO BUILDING CODE AND ANY ADDITIONAL EQUIP. EQUIPMENT P.T. PRESSURE TREATED 12. EXTERIOR 5HEATHIN6 TO BE COVERED WITH 'TYVEK' HOU5E WRAP OR REQUIREMENTS AS SET FORTH IN THE MANUFACTURER'S CODE 11. EXTERIOR &LAZING IN BUILD)IN5S LOCATED IN WINDBORNE DEBRIS REGIONS APPROVED EQUAL. EVALUATION REPORT. SHALL BE PROTECTED FROM MINDBORNE DEBRIS. GLAZED OPENING EXIST. EXISTING REQ'D REQUIRED 11. THESE SET OF PRANINC75 ARE THE PROPERTY OF ANTHONYr PORTILLO, RA PROTECTION SHALL MEET THE I REQUIREMENTS OF THE LARGE MISSILE TEST OF +J 70 AND SHALL NOT BE ALTERED OR BE REPRODUCED WITHOUT HRITTEN 15. BLOCK EXTERIOR STUD WALLS AT HALF STORY HEIGHTS AND AT 1.4. STRUCTURAL COMPOSITE LUMBER: SINGLE MEMBERS OR ASSEMBLIES ASTM EICi96 AND A5TM EI666. 6ARAOE DOOR GLAZED OPENING PROTECTION EXT. EXTERIOR Ri RISER PERMISSION FROM THE ARCHITECT. USING STRUCTURAL COMPOSITE LUMBER SHALL MEET THE PROVISIONS OF SHALL MEET THE REQUIREMENTI'5 OF AN APPROVED IMPACT-RESISTANT r 1 _ UNSUPPORTED EDGE SEAMS OF EXTERIOR SHEATHING. ASTM D5456 STANDARD SPECIFICATION FOR EVALUATION OF STANDARD OR AN5I/DA5MA II°5. (NYS RG R501.2.1.2) F.A.I. FRESH AIR INTAKE RM. ROOM V 12. THE ARCHITECT IS NOT RETAINED FOR SUPERVISION OF THNE WORK AND IS STRUCTURAL COMPOSITE LUMBER PRODUCTS, THIS DOGUMEN, THE ^ ` D RESPONSIBLE FOR DESIGN INTENT ONLY. E PROVIDE " AND AT BRACING AT JOISTS, STUDS, AND RAFTERS WHEN SPANS GOVERNING BUILDING CODE, AND ANY ADDITIONAL REQUIREMENTS AS 12. AS AN ALTERNATIVE TO NOTE #11 ABOVE, WOOD STRUCTURAL PANELS WITH FAR FLOOR AREA RATIO R.R. ROOF RAFTER W EXCEED 8'-O" AND AT EVERY 8'-O". 15. THE CONTRACTOR SHALL OBTAIN CERTIFICATE OF OCCUPANCY. SET FORTH IN THE MANUFACTURER'S GORE EVALUATION REPORT. A THICKNESS OF NOT LE55 THAN J" AND A SPAN OF NOT MORE THAN 6' 5HALL 15. TOP PLATES TO BE DOUBLED AND LAPPED AT CORNERS, 5EE AL50 PACE BE PERMITTED AS GLAZING PROTECTION. PANELS SHALL BE PRECUT AND F.A.V. FRESH AIR VENT 5TL. STEEL 4_j I.S. PREFABRICATED WOOD TRUSSES: ASSEMBLIES USING PREFABRICATED ATTACHED TO THE FRAMING SWRROUNDING THE OPENING. PANELS SHALL BE • 14. THE CONTRACTOR SHALL KEEP PREMISES REASONABLY GLLEAN AT ALL 6-004. WOOD TRUSSES SHALL MEET THE PROVISIONS OF THI5 DOCUMENT, THE PREDRILLED AND SECURED WITH THE ATTACHMENT HARDWARE PROVIDED AS FF FINISHED FLOOR S.V. SMART VENT TIMES. AT THE COMPLETION OF WORK, THE CONTRACTOR SHAkLL REMOVE ALL 16. APPLY ALL CONDITIONS ADDRESSED IN FA5TENIN& SCHEDULE AS 60VERNIN6 BUILDING CODE, AND ANY ADDITIONAL REQUIREMENTS AS PER THE ANGHORACE METHOD) SELECTED IN ACCORDANCE WITH TABLE RUBBISH, WASTE MATERIALS, TOOLS, ETC., GLEAN GLASS AND) LEAVE WORK NECESSARY. SET FORTH IN AN51/TPI I NATIONAL DESIGN STANDARD FOR METAL PLATE R501.2.1.2. ATTACHMENT HARDWARE 5HALL BE PERMANENT FF ELEV. -� FIRST FLOOR ELEVATION TBD TO BE DETERMINED BROOM GLEAN. CONNECTED WOOD TRUSS CONSTRUCTION, THE TRUSS DESIGN DRAWINGS, CORROSION-RE515TANT AND TIHE ANCHORS SHALL BE PERMANENTLY INSTALLED 1 c 15. THE CONTRACTOR SHALL CARRY WORKMAN'S GOMPENSATIION AND GENERAL 1'1• PROVIDE ALL NAILING AND 5TRAPPING ADDRESSED ON PAGES 6-005. OR THE MANUFACTURER'S CODE EVALUATION REPORT. ON THE BUILDING. F.J. FLOOR JOISTS TEMP GL. TEMPERED 6LA55 v LIABILITY INSURANCE. ALL SHALL COMPLY WITH STATE AND ILOGAL CODES T�1 AND ORDINANCES. le). AT "WET WALL" PARALLEL TO JOISTS FRAME DOUBLE JOIST AS PER CODE. 1.6. GYPSUM: GYPSUM MATERIAL USED IN A STRUCTURAL APPLICATION SHALL FOUND. FOUNDATION THK. THICK GENERALLY, SEPARATE DOUBLE JOIST THE THICKNESS OF WALL ABOVE. SUB MEET THE PROVISIONS OF ASTM 056 SPECIFICATION FOR GYPSUM _ FLOOR SHALL NEVER EXCEED A 16" SPAN, WALLBOARD, A5TM C37 SPECIFICATION FOR GYPSUM LATH, OR ASTM C7'1 FRCE FLOOD RESISTANT CONSTRUCTION ELEVATION T.O.W. TOP OF WALL I6. THE CONTRACTOR SHOULD FULLY 6UAI F T L HIS WORK EIA THE WORK OF SPECIFICATION FOR GYPSUM 5HEATHIN6 BOARD. THE COMPLETION ON OF PROJECT. FOR A PERIOD OF AT LEAST ONE YEAR AFTER A. AT ROUGH OPENIN65 PROVIDE ALL APPLICABLE NAILING AND 5TRAPPING PLUMBING FR. FRAME Tr TREAD n l COMPLETION OF PROJECT. AS PER PAGE 6-005. 1.7. HARDBOARD: HARDBOARD USED IN A STRUCTURAL APPLICATION SHALL I. CONTRACTOR SHALL IN5TALLL WATER SUPPLY, DRAIN, WASTE, AND VENT(DWV) W 17. THE CONTRACTOR SHALL INDEMNIFY AND HOLD HARMLESSi THE OWNER, MEET THE PROVISIONS OF AN51/AHA A155.4 5A510 HARDBOARD OF SYSTEMS TO NY5 PLUMBING CODE AND NYS DEC REGULATIONS. FRPR. FIREPROOF TYP. TYPICAL ARCH ITEGT/ENGINEER, AND THEIR A6ENT5 AND EMPLOYEES FROM AND 20. "P.T." SPECIFIES PRESSURE PRE5ERVATIVELY TREATED LUMBER IN AN51/AHA AL55.6 HARDBOARD SIDING. Q AGAINST ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES, INGLUDIN6 ACCORDANCE w/ AWPA 022;WHERE DRILLING AND/OR GUTTING OCCURS, FIELD 2. PROVIDE HOT AND GOLD SHfUT OFF VALVES AT ALL FIXTURES. FTC. FOOTING U.O.N, UNLE55 OTHERWISE NOTED ATTORNEYS FEES ARISING OUT OF OR RESULTING FROM THE !PERFORMANCE OF TREAT LUMBER w/ COPPER NAPTHENATE WHICH SHALL CONTAIN 2% COPPER 1.8 STRUCTURAL PANELS: THE WORK PROVIDED THAT ANY SUCH CLAIM, DAMAGE, LOSS, OR EXPENSE (A) METAL BY REPEATED BRUSHING, DIPPING, OR SOAKING UNTIL THE WOOD 3. ALL WATER PIPING TO HAVE GLEAN DOTS AT ALL CHANGES IN DIRECTION GYP. BD. GYPSUM BOARD VERT. VERTICAL ABSORBS NO MORE. ALSO, FOR HARDWARE USED WITH P.T. LUMBER, 1.5.1. PLYWOOD: PLYWOOD USED IN STRUCTURAL APPLICATIONS 5HALL AND AT BASE OF VERTICAL W ABTE PIPES. IS ATTRIBUTABLE T BODILY INJURY, SIC15LE PROPERTY ERTYDISM (O HE DEATH OR TO CONTRACTOR 15 TO INSTALL HARDWARE THAT 15 SPECIFIED BY P.T. LUMBER MEET THE PROVISIONS OF U.5. DEPARTMENT OF COMMERCE H.D. HOLD DOWN V.I.F. VERIFY IN FIELD INJURY IN OR DESTRUCTION OF USE RE LU PROPERTY (OTHER. THAN THE WORK MANUFACTURER SUCH AS: HANGERS, NAILS, SCREWS, FLASHING, ANCHOR BOLTS, VOLUNTARY PRODUCT STANDARD I (PS 1) CONSTRUCTION AND 4. USE 4" CAST IRON THROUGH FOUNDATION WALL AND PITCHED AT 115" PER ITSELF INCL.N PA THE LOSS OR USE RESULTING THEREFROM). (T IS CAUSED IN ETC. FOR LOCATIONS SUCH A5: LEDGER BD., SILL PLATE, DECK CONSTRUCTION, INDUSTRIAL PLYWOOD, U.S. DEPARTMENT OF COMMERCE VOLUNTARY FOOT. HDR HEADER w/ WITH WHOLE OR IN PART BY ANY NEGLIGENT ACT OR OMISSION OF THE ETC. ANY REFERENCES TO GGA ARE TO REPLACED WITH P.T. PRODUCT STANDARD 2 (P52) PERFORMANCE STANDARD FOR CONTRACTOR, ANY SUBCONTRACTOR, ANYONE DIRECTLY OR INDIRECTLY WOOD-BASED STRUCTURAL- USE PANELS, APPLICABLE CODE 5. GENERAL TRAP AND WASTE 51ZES AS FOLLOWS, UNLE55 OTHERWISE NOTED: HNOR HANGER WD. WOOD EMPLOYED BY ANY OF THEM, OR ANYONE: FOR WHOSE ACTS MANY OF THEM MAY 21. LVL (LAMINATED VENEER LUMBER) DENOTES EITHER OF THE FOLLOWING: EVALUATION REPORTS. - D15H WASHER..........................................2" BE LIABLE REGARDLESS OF WHETHER OR. NOT IT IS CAUSED [IN PART BY A A. WEYERHAEUSER TRUS JOIST 2.OE MIGROLLAM LVL - KITCHEN SINK.........................................2" HOR. HORIZONTAL ZR ZONING RESOLUTION PARTY INDEMNIFIED HEREUNDER. B. &EORGIA PACIFIC 2.OE 6-P LAM LVL 1.5.2. ORIENTED-STRAND BOARD (055), WAFERBOARD ORIENTED-STRAND - LAVATORY................................................2" 15. ALL MATERIALS, ASSEMBLIES, AND METHOD OF CONSTRUG%TION INGLUDIN6 P5L (PARALLEL STRAND LUMBER) DENOTES: BOARD OR WAFERBOARD USED IN STRUCTURAL IONS SHALL MEET - SHOWER/TUB...........................................2" BUT NOT LIMITED TO FORM-WORK, BLOCK-WORK, FRAMING, NANILIN6, PLACING A. WEYERHAEU5ER TRU5 JOINT 2.2E PARALLAM PSL THE PROVISIONS OF U.S. DEPARTMENT OF COMMERCE VOLUNTARY - TOILET.........................................................5 OF CONCRETE, ETC. ARE TO BE CAREFULLY SUPERVISED BY 1THE CONTRACTOR ALL TO BE INSTALLED AS PER MANU. SPEG.'s PRODUCT STANDARD 2 (P52) PERFORMANCE VOLUNTARY PRODUCT - LAUNDRY ..................................................2" TO BE SURE THEY ARE IN ACCORDANCE WITH THE DRAWIN65, SPECIFICATIONS, STANDARD FOR WOOD-BASED STRUCTURAL- USE PANELS OR - FLOOR DRAIN...........................................5"APPLICABLE CODES AND GOOD PRACTICE. DEVIATIONS FROI'M THE DRAWINGS 22• I-JOIST FLOOR SYSTEMS SHALL BE IN ACCORDANCE WITH THE WOOD APPLICABLE CODE EVALUATION REPORTS. I S e 7 O 7 I U I =� 75 AND SPECIFICATIONS WILL NOT BE PERMITTED WITHOUT WRI I I EN FRAMING MATERIAL STANDARDS SECTION, THE GOVERNING BUILDING CODE, 6. ALL SYSTEMS TO HAVE ONE: 5" MAIN VENT STACK AND INCREASED TO 4" AUTHORIZATION OF THE ARCH ITEGT/ENOINEER. AND ANY ADDITIONAL REQUIREMENTS SET FORTH IN THE MANUFACTURER'S 1.5.5. PARTICLE BOARD: PARTICLE BOARD USED IN STRUCTURAL THROUGH ROOF. CODE EVALUATION REPORT. APPLICATIONS SHALL CONFORM TO ANSI A205.1 AND ANY 19. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY SHOP' PRANIN05 REQUIREMENTS AS SET FORTH IN THE MANUFACTURER'S CODE 7. PROVIDE FR05T-PROOF HOSE BIBS WITH EA51LY ACCESSIBLE DRAIN $ PROPOSED DESIGN CODE FRESGRIPTI\/E VALUE 4 NEEDED, UNLE55 OTHERWISE SPECIFIED. ALL DIMENSIONS AND> CONDITIONS 25. NOTCHES IN THE TOP OR BOTTOM EDGE OF 50LID SAWN RAFTERS SHALL EVALUATION REPORT. DRAIN GOOKS AS REQ'D. HO5E BI55 SHALL BE PROVIDED WITH BAGKFLOW COMPONENT VALUE G I T>4T1 ON (PER 2020 NYSEGGG) GOMPL II ES PERTAINING ARE TO BE FIELD VERIFIED. NOT BE GUT IN THE MIDDLE ONE-THIRD OF THE RAFTER SPAN. NOTCHES IN THE PROTECTION. OUTER THIRDS OF THE SPAN SHALL NOT EXCEED ONE-SIXTH OF THE ACTUAL 1.6.4. FIBERBOARD: FIBERBOARD USED IN STRUCTURAL APPLICATIONS 20. CONTRACTOR TO REMOVE $ RELOCATE AS REQUIRED ALL EXISTING WORK RAFTER DEPTH. WHERE NOTCHES ARE MADE AT SUPPORTS THEY SHALL NOT SHALL MEET THE PROVISIONS OF AN51/AHA AI94.1 CELLULOSIC 5. WASTE FROM CLOTHES WASWERS AND LAUNDRY TUBS ARE TO BE PROVIDED WHICH INTERFERES WITH NEW CONSTRUCTION IN A WORKMAN LIKE MANNER. EXCEED ONE-FORTH THE ACTUAL RAFTER DEPTH, BORED HOLES ARE LIMITED FIBERBOARD OR A57M 0205 STANDARD 5PECIFICA7ION FOR WITH BACK FLOW PROTECTION.,IN DIAMETER TO ONE-THIRD THE ACTUAL RAFTER DEPTH AND THE EDG MAX. U-VALUE = 0.27E OF THE CELLULOSIC FIBER INSULATING BOARD. FENESTRATION U-VALUE U-VALUE = 0.25 MAX. AIR LEAKAGE = 0.30 GFM/SF YES 21. ALL MATERIALS ARE TO BE INSTALLED AS PER MANUFACTIURER'S HOLE SHALL NOT BE CLOSER THAN 2 INGHE5 TO THE TOP OR BOTTOM EDOE5. Cl. THE WATER SUPPLY AND SAINITARY SYSTEM SHALL COMPLY WITH LOCAL (VERTICAL FENESTRATION) AIR LEAKAGE = 0.50 GFM/5F SPECIFICATIONS, UNLESS NOTED OTHERWISE. 1.6.5. STRUCTURAL PANEL 51DIN6 STRUCTURAL PANEL SIDING USED IN HEALTH DEPARTMENT STANDARDS AND REGULATIONS. PER R402.5.3 $ TABLE R402.1.2 - CLIMATE ZONE 4 24. NOTCHES IN EITHER EDGE OF STUDS SHALL NOT BE LOCATED IN THE STRUCTURAL APPLICATIONS SHALL MEET THE REQUIREMENTS OF U.S. MIDDLE ONE-THIRD OF THE STUD LENGTH. NOTCHES IN THE OUTER THIRDS OF DEPARTMENT OF COMMERCE VOLUNTARY PRODUCT STANDARD 1 10. APPROVAL AND INSPECTION 15 REQUIRED BY LOCAL JURISDICTION PRIOR 22. PROVIDE FIREBLOGKING AS PER NEW PORK AGGESSIBILIITY STANDARDS. THE STUD LENGTH SHALL NOT EXCEED 25% OF THE ACTUAL DEPTH. BORED (P5- 1), THE GOVERNING BUILDING CODE, AND ANY ADDITIONAL TO CONGEALMENT OF PLUMBIMO. CEILING R-VALUE R-4Q BATT INSULATION FlN. R-VALUE = 401 YES 23. PLEASE NOTE THAT THESE PLANS ARE° PROTEGTI=D A6Aii SST ANY HOLES 5HALL NOT EXCEED 405� OF THE ACTUAL STUD DEPTH AND THE EDGE REQUIREMENTS AS SET FORTH IN APPLICABLE CODE EVALUATION R TABLE R402.1.3 - CLIMATE ZONE 4 UNAUTHORIZED USE UNDER FEDERAL LAW BY THE ARCHITECTURAL WORKS OF THE HOLE SHALL NOT BE 01-05ER THAN 5/6" TO THE EDGE OF THE STUD. REPORTS. 11. NOTCHING AND BORING OF ST1.05, JOISTS, RAFTERS AS PER BUILDING CODE. COPYRIGHT PROTECTION ACT OF 111,10 (AWCPA), WHICH HAS SEVERE PENALTIES. NOTCHES AND HOLES SHALL NOT Or-OUR IN THE SAME CRO55-5ECTION. NO NOTCHING AND BORING OF STRUCTURAL MEMBERS SHALL BE PERMITTED 2.2. FASTENERS AND CONNECTORS: ALL FA5TENER5 AND CONNECTORS SHALL NOR ANY POTENTIAL DAMAGE THEREOF. MIN. R-VALUE = 30 (CAVITY), OR 25. FOR NEW WALLS, A PERFORATED 5HEARWALL SYSTEM IS USED. THE CONFORM TO THE STANDARDS SPECIFIED IN M 2.2.1 THROUGH M 2.2.1. 20 (CAVITY) + 10 (CONTINUOUS), OR GENERAL WIND PROTECTION CONNECTION NOTES: CONTRACTORS ATTENTION 15 DIRECTED TO THE APPLICABLE DETAILS, 12. PER NYS PG 425.4, A 4N5" OL05ET BEND SHALL BE AN ACCEPTABLE EXTERIOR (2"xb") WOOD R-31.5 5PRAY FOAM CAVITY ADAPTED FROM STANDARD FOR HURRICANE RESISTANT RE51D)ENTIAL NOTES, AND TABLES ON PAGE 6-005 d 6-004. THE FASTENING SCHEDULE 2.2.1. BOLTS: BOLTS SHALL COMPLY WITH ANSI/ASME B 16.2.1 SQUARE AND WATER CLOSET CONNECTION. HHERE A 5" BEND IS UTILIZED, A 4"x3" FLANGE FRAME WALL R-VALUE INSULATION (4.5" THICK a R-VINCH) 13 (CAVITY) + 20 (CONTINUOUS), OR YES CONSTRUCTION;SSTD 10-qa AND 2016 SBG HIGH WIND EDITION WOOD FRAME SPECIFIES THE REQ'D NAILING FOR THE 5HEATHIN6 (ANY NAILING HEX BOLTS AND SCREWS (INCH SERIES). SHALL BE INSTALLED TO RECEIVE THE FIXTURE HORN. 20 (CONTINUOUS) Z CONSTRUCTION SPECIFICATIONS ON THE FLOOR PLANS SHALL 5UPER5EDE THE FASTENING PER TABLE R402.1.3 - CLIMATE ZONE 4 I. A CONTINUOUS LOAD PATH BETWEEN FOOTINGS, FOUNDATkON WALLS, SCHEDULE). HOLDOWN5 OPERATE IN CONJUNCTION WITH THE PERFORATED 2.2.2. LA6 SCREWS: LA6 50REWS OR LA6 BOLTS SHALL COMPLY WITH AN51/ FLOORS, STUDS AND ROOF FRAMING :5HALL BE PROVIDE=. SHEARWALL SYSTEM (INSTALL AS PER APPLICABLE DETAILS 4 MANU. SPEC.'S). A5ME 5I6.2.1 5QUARE AND HEX BOLTS AND SCREW5 (INCH SERIES). p 2. APPROVED CONNECTORS, ANCHORS AND OTHER FASTENINV6 DEVICES NOT HOLDOWN LOCATIONS ARE SPECIFIED ON THE FOUND./FLOOR PLANS. v 2.2.5. TRU55 METAL CONNECTOR PLATES: TRU55 METAL CONNECTOR PLATES ELECTRICAL: MIN R-VALUE = 30 (CAVITY), OR INCLUDED IN THE STANDARD BUILDING CODE, SECTION 23CD6 OF IBC SHALL 26. COLUMN BEARING AS FOLLOWS: SHALL MEET THE REQUIREMENTS OF AN51/TPI I NATIONAL DESIGN I. ALL NEWLY INSTALLED ELECTRICAL WORK OR APPLIANCES SHALL CONFORM Icl (CAVITY) + -1.5 (CONTINUOUS), OR BE USED IN ACCORDANCE WITH MANUFACTURER'S RECOMNIENDATION5. WOOD POSTING TO BE BLOCKED SOLID TO FOUND. WALL w/END GRAIN, STANDARD FOR METAL PLATE CONNECTED WOOD TRUSS CONSTRUCTION, TO 2011 NATIONAL ELECTRIC (OODE, NFPA 'i0 AND 2025 NEW YORK STATE FLOOR R-VALUE R-50 BATT INSULATION 20 (CONTINUOUS) YES 3. METAL PLATES, CONNECTORS, SCREWS, BOLTS AND NAILS EXPOSED TREATED WOOD 4 FLA5HINC. STEEL COLUMNS ARE TO BEAR UPON FOUND. THE 6OVERNING BUILDING CODE, AND ANY ADDITIONAL REQUIREMENTS ENERGY CONSERVATION CONSTRUCTION CODE. PER TABLE R402.1.3 - CLIMATE ZONE 4 DIRECTLY T THE WEATHER , SUBJECT TO SALT CORROSION IN COASTAL WALL w/STEEL SHIMS d A MIN. 5/4" OF NON-SHRINK GROUT. AS SET FORTH IN THE MANUFACTURER'S CODE EVALUATION REPORTS. AREAS SHALL BE STAINLESS STEEL EC HOT DIPPED RR,0516ALNWA N IN SECURE W (2) 1/2" 0 ANCHOR BOLTS (4" LONG EXPAN51ON BOLTS ® 2. CONTRACTOR WILL FURNISH! A FIRE UNDERWRITERS CERTIFICATE UPON EXIST. WALLS 6 12 LONG HOOKED BOLTS ® NEW FOUND. WALLS). FOR ANY 2.2.4. METAL CONNECTORS WHERE METAL PLATE OR STRAPPING SIZE AND COMPLETION OF WORK. COMPLIANCE STATEMENT: STATEMENT: Q 4. WHERE WINDOWS AND DOORS INTERRUPT WOOD STRUCTURAL PANEL POSTING ® G.M.U. WALL SEE PLAN FOR REQUIRED REINFORCING (® MIN. 16" GAGE ARE SPECIFIED, MINIMUM A5TM A655, STRUCTURAL QUALITY, TO THE 5E5T OF MY KNOWLEDGE, BELIEF, AND PROFE55IONAL JUDGMENT, THESE PLANS AND 5PEGIFIGATION5 ARE IN a IN CON'IFORMANCE WITH NFPA 72:SMOKE DETECTORS OTHER METAL CONNECTORS SHALL 5 E USED SHALL 5 L B . . , 5HEATHIN6 AND SIDING, FRAMING ANCHORS OR GONNEGTC'>RS SHALL BE WIDE 3 COURSES OF SOLID BRICK MASONRY CENTERED ® POSTING, U.O.N.). GRADE 35 STEELCOMPLIANCE WITH THE 2025 NYS ENERGY CONSERVATION CONSTRUCTION GODS USING GRAFTER 4 [RE]. PROVIDED AT THE TOP AND BOTTOM OF CRIPPLE STUDS, HEADER STUDS HOWEVER, WHEN COLUMN OR POSTING 15 PART OF THE LOAD PATH FOR USE MEET THE REQUIREMENTS OF THE C70VERNINO BUILDING GORE AND ANY - GENERALLY, VERIFY OR PROVIDE HARD WIRED AND AT LEAST ONE STUD AT EACH SIDE OF OPENING. IN A 5HEARWALL, ALL ANCHORS MAKING AN ATTACHMENT ARE TO BE w/ ADDITIONAL REQUIREMENTS AS SET FORTH IN THE MANUFACTURERS SMOKE DETECTORS w/ BATTERY BACK-UP IN: PROJECT: STANDARD SHEARWALL HARDWARE (W NOTED VALUES) B ANCHOR BOLTS, CODE EVALUATION REPORTS. A. EACH SLEEPING ROCnM 5. RIDGE STRAPS SHALL BE ATTACHED TO EACH PAIR OF OPPOSING U.O.N. WITH TOP xb GAB ERATE S ® STEEL COLUMNS TO BE MIN. BENT PLATE 6" LONG 2.2.5. NAILS: NAILS SHALL COMPLY WITH A57M F 1667 STANDARD M ICHALECKO RAFTERS EXCEPT WHERE COLLAR, TIES OF I OR 2 x4 LUMBER 15 W 6 RISE $ w/ (2) /a 0 BOLTS THROUGH CENTER LINE OF VERTICAL LE05 SPECIFICATION FOR DRIVEN FASTENERS: NAILS, SPIKES, AND STAPLES. B. OUTSIDE OF EACH SPA SLEEPING LOCATED IN UPPER THIRD OF ATTIC SPACE AND ATTACH TO EACH PAIR OF SET 6 DIST., U.O.N. - ADDITIONAL INFO. IS FOUND ON PAGE 6-005. AREA IN THE IMMEDIATIE VICINITY OF RAFTERS. 2.2.6. PNEUMATIC NAILS AND STAPLES: PNEUMATIC NAILS AND STAPLES THE BEDROOMS (6ENERRALLY THE HALLWAY) REPAIRS 6. UPLIFT CONNECTORS SHALL BE PROVIDED AT EACH RAFITER BEARING. MECHANICAL CONNECTIONS: SHALL MEET THE REQUIREMENTS OF THE 60VERNIN6 BUILDING CODE AND ANY ADDITIONAL REQUIREMENTS AS SET FORTH IN THE C. EVERY LEVEL OF PPY�ELLING I. ALL MECHANICAL CONNECTIONS SPECIFIED AS "SIMPBON" MAY BE MANUFACTURER'S CODE EVALUATION REPORTS. (BASEMENT, FIRST FLOOR, Q SECOND FLOOR, ETGJ 7. FLOOR TO FLOOR HOLD-DOWNS TO BE PROVIDED EVERY' 45" AND EVERY SUBSTITUTED WITH AN APPROVED EQUAL PRODUCT. 16" WITHIN 4' OF EXTERIOR CORNERS. 2.2.1. SCREWS: 5GREW5 SHALL COMPLY WITH AN51/A5ME B 15.6.1 6. SILL PLATE TO FOUNDATION ANCHORAGE;SILL PLATE SHALL BE ANCHORED 2. THE SUBSTITUTION SHALL MEET ALL OF THE MINIMUM CRITERIA SPECIFIED WOODSGREW5 (INCH SERIES). 11175 OLD SOUND AVE. BY SIMPSON MANUFACTURER. MATTITUCK NY 11952 TO THE FOUNDATION WITH ANCHOR BOLTS HAVING A MIN. !BOLT DIAMETER OF I" AND 5"x5"xj" WASHERS. A MINIMUM OF ONE ANCHORZ BOLT SHALL BE 5. ALL LOADING CAPACITIES SHALL MATCH EXACTLY OR EXCEED VALUES PROVIDED WITHIN b TO 12 INCHES OF EACH END OF EAGHI PLATE. ANCHOR INDICATED IN "SIMPSON" PRODUCT LITERATURE. THERE MAY BE SEVERAL BOLTS SHALL HAVE A MINIMUM EMBEDMENT OF 7" IN CONCRETE/MA50NRY LOADING VALUES, CONTRACTOR SHALL CONTACT ARCHITECT IF ANY FOUNDATIONS. ANCHOR BOLTS SHALL BE LOCATED WITHIM 12" OR CORNERS LOADING VALUES ARE LESS THAN WHAT IS SPECIFIED BY "51MPSON" DRAWING TITLE: AND AT SPACING NOT EXCEEDING 4' ON CENTER. 4. ALL MECHANICAL CONNECTIONS SHALL BE HOT DIPPED GALVANIZED GENERAL NOTES CODES AND REFERENCE STANDARD: I. ALL NEW WORK PERFORMED SHALL CONFORM TO THE 20255 NEW YORK 5. INSTALLATION PROCEDURES SHALL ALWAYS BE CARRIED OUT AS PER ENERGY TABLE STATE BUILDING CODE, 2025 NEW YORK STATE RESIDENTIAL CODE, 2025 MANUFACTURER SPECIFICATIONS OF THE PRODUCT BEING INSTALLED. NEW YORK STATE PROPERTY MAINTENANCE GORE, AND 20255 NEW YORK STRUCTURAL DESIGN CHARTS STATE ENERGY CONSERVATION CONSTRUCTION CODE. 6. ALL FASTENING CRITERIA SHALL BE CARRIED OUT AS PER MANUFACTURER 2. REFERENCE STANDARD USED FOR ALL, WOOD FRAMING, CONNECTIONS OF SPECIFICATIONS OF THE PRODUCT BEING INSTALLED 7AEL.E R501.1 CLIMATIC $ GEOGRAPHIC DESIGN CRITERIA STRUGTURL. DESIGN LOADS WOOD FRAMING, AND CONNECTION TO FOUNDATION - 2024 WOOOD FRAME 7. VARIATIONS IN CONNECTOR GONFI&URATION SHALL BE APPROVED BY ALLOWABLE DEFLECTION OF STRUCTURAL MEMBERS CONSTRUCTION MANUAL BY THE AMERIGAN FOREST ✓f PAPER ASSOCIATION ARCHITECT GROUND SNOW LOAD (AF4PA) AMERIGAN WOOD COUNCIL (ANC:). (p PER ASGE 7-22) 50 LBS USE LIVE LOAD DEAD LOAD PAGE: 8. ALL CONNECTORS SPECIFIED AS A "SIMPSON".TOP MOUNTED BEAM ALLOWABLE: 3. ALL PLUMBING WORK SHALL CONFORM TO THE 2025 NEW`rfORK STATE HANGER SHALL BE ALLOWED TO BE SUBSTITUTED WITH A TOP MOUNTED STRUCTURAL MEMBER DEFLEGT101�N BASIC WIND SPEED 150 MPH G-002mOO PLUMBING GORE. BEAM HANGER ONLY ALONG WITH SPECIFICATIONS LISTED ABOVE. EXTERIOR BALCONIES 40 psf 15 psf 4. ALL MECHANICAL WORK SHALL CONFORM TO THE 2025 NEW YORK STATE RAFTERS HAVING SLOPES GREATER THEN 5/12 EXPOSURE CATEC70RY B MECHANICAL CODE AND 2025 NEW YORK: STATE FUEL 6A5 CODE. L/160 DECKS 40 psf 15 psf W/ NO FINISHED CEILING ATTACHED TO RAFTERS SEISMIC DESIGN CATEGORY B S. ALL ELECTRICAL WORK SHALL CONFORM TO 2011 NATIONAL ELECTRIC PASSENGER VEHICLE GARAGES 50 psf A5 PER PLAN CODE, NFPA 70 AND 2025 NEW YORK STATE ENERGY CONSEIRVATION INSULATION INTERIOR WALLS 4 PARTITIONS H/150 DATE: 04/29/26 2 OF 6 CONSTRUCTION CODE. I. ALL EXTERIOR WALLS AND ROOFS SHALL BE INSULATED WITH FOIL FACED WEATHERING SEVERE UNINHABITABLE ATTICS WITHOUT 5TORA&E FIBER&LA55 BATT INSULATION BY JOHN MANVILLE OR APPROVED EQUAL. (MAX CLEAR HOT < 42"9 10 psf 15 psf FOIL TO BE PLACED TOWARD HARM SIDE. FLOORS $ PLASTERED CEILINGS L/360 FR05T LINE DEPTH 3'-O" GYPSUM WALL BOARD W UNINHABITABLE ATTICS WITH STORAGE I. GYPSUM WALL BOARD SYSTEMS SHALL BE OF A TAPE JOINT AND JOINT 2. PROVIDE 2" R-10 RIGID FOAM INSULATION FOR EXTERIOR FOUNDATION (MAX CLEAR HOT > 42") 20 psf 15 psf COMPOUND METHOD. ALL OTHER STRUCTURAL MEMBERS L/240 WALLS FROM b" BELOW GRADE TO 24" BELOW GRADE IF DESIRED BY TERMITE MODERATE TO HEAVY HABITABLE ATTICS 8 CONTRACTOR OR OWNER. CARE SHOULD BE TAKEN NOT TO DAMAGE I ATTICS SERVED BY FIXED STAIRS 30 psf 15 psf 2. ALL 6YP5UM BOARD SHALL BE 1/2" ON WALLS AND CEILING, UNLESS FOUNDATION WATERPROOFING. EXTERIOR WALLS W/ PLASTER OR STUCCO FINISH H1560 ICE BARRIER REQUIRED YES OTHERWISE NOTED. WATER RE515TANT (H.R.) AT BATHROOMS: AND WHERE ROOMS OTHER THAN SLEEPING ROOMS 40 psf 15 psf DEEMED APPLICABLE. 3. GENERALLY, UNLESS NOTED OTHERWISE, INSULATE AS FOLLOWS: - cl" R-50 FOR FLAT CEILINGS EXTERIOR WALLS - WIND LOADS W/ BRITTLE FINISHES L/240 y 3. 5/6", ONE HOUR RATED, TYPE 'X' GYPSUM BOARD ON CEILING AND WALLS - 6.25" R-500 FOR VAULTED AND CATHEDRAL CEILINGS SLEEPING ROOMS 30 psf 15 psf - !: (WHERE APPLICABLE) AT HEAT PRODUCING EQUIPMENT TO EXTEND THREE FEET - 3.5 R-13 FOR 2,x4 WALL CONSTRUCTION EXTERIOR WALLS WIND LOADS W/ FLEXIBLE FINISHES L/120 IN EACH DIRECTION BEYOND THE UNIT(S). ALSO AT HEAT PRODUCING - 5.25" R-21 FOR 2"xb" WALL CONSTRUCTION STAIRS 40 psf 15 psf EQUIPMENT, CONCRETE FLOOR OR IF PLACED ON WOOD FRAME, INSTALL - 5.25" R-21 FOR FLOORS , CONCRETE PANELS OF 5/6" THICKNESS MINIMUM. 6UARDRAIL5 AND HANDRAILS 200 psf 15 psf 4. FINISH JOINTS, J-BEADS, NAIL DIMPLES, CORNERS, AND EDGES SHALL BE TAPED AND RECEIVE THREE GOATS OF JOINT COMPOUND. ALLOW 24 HOURS TO DRY BETWEEN GOATS. FINAL GOAT TO BE 5ANDED SMOOTH. ROOF LOADING (LIVE _ &ROUND SNOW LOAD, p� 50 psf 15 psf 5. METAL CORNER NOTE: ASP GROUND SNOW LOADS, p BEAD TO BE USED ON ALL OUTSIDE CORNERS AND AROUND 9(A5o)=o.7p9 ALL OPENIN65. *ALL STRUCTURAL DESIGN CONSIDERATIONS ARE IN CONFORMANCE WITH 6. FASTEN GYPSUM BOARD A5 PER FASTENING SCHEDULE ON PAGE 0-003. ASGE 7-22 (MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES) HOL.DONN DETAILS T`rF GAL_ NAILINO/STRAFFINO REOU REMEN,TS FOR FA57ENINO SCHEDULE A ALL HARDWARE TO BE INSTALLED AS PER MANU. SPEG.'s; MANUFACTURER UAL. FT, SHEAR, LATERAL N I ND RES 1 STANCE NOTE: THIS SCHEDULE DOES NOT INCLUDE NAILING FOR METAL FRAMING STRAPS 5U55TITUTIOM5 MAY BE MADE WHEN LOAD CAPACITIES ARE MATCHED (SEE PAGE 0-005 FOR STRAPPING AND NAILING REQUIREMENTS, Q BALL STRAPPING TO BE IY4"x 20 C AUC E -- "SIMPSON" EQUIVALENT — 0520 (GO I LED STRAP AND ROUGH OPENING FRAMING REQUIREMENTS) STRAP) AND NAILING 15 A GENERAL SPECIFICATION, IT APPLIES UNLESS NOTED OTHERWISE ui w FUSE IOd NAILS IF STRAPPIINC IS OVER PLYWOOD; T`I'P. FOR ALL (SCHEDULE AS PER AWG 2015 WOOD FRAME CONSTRUCTION MANUAL TABLE 5.1) J c6 FASTENER 5PEG. FASTENER M HOEDOWN HOEDOWN ��' CONNECTION NAIL NO OR I D DESCRIPTION AND QUANTITY SPACING E FOR CT NEW 4 EXIST. � O FOUNDATIONS AT RAFTER TO RIDGE �� ROOF CE I L I NO FRAM I NO I.DIM's ARE ALL MIN.«'s BASED ON USE OF ONLY A I6d ` ENDWALL „„„.- CONNECTION: COMMON NAIL w/o PRESORED HOLES, i ENDWPs.LL „' 2„ RAFTER TO TOP PLATE (TOE-NAIL) SEE PAGE G-003 PER RAFTER 0 C N z O (5) 2x FULL (5) 2x FULL CORNER STUD 2.WOOD 15 ASSUMED TO BE DF,02 4 BTR. IN DRY USE HEIGHT STUD HEIGHT STUD ONNEGTED TO , "=- „ " FOR STRAP - 5 8 d* COMMON R.R. 2 SERVICE •CO Lj) � Cr \ CORNIER STUD CEILING JOIST TO TOP PLATE (TOE-NAIL) SEE PAGE 6-005 PER JOIST '— 0 r- TRANSFER SHEAR NAILS ® EA. END OF STRAP. GONNfEGT'ED TO 3.SHOULD THE WOOD IN USE PRESENT A SPLIT POTENTIAL C 2 X = N TRAM51FER SHEAR \ry (EVIDENT DURING INITIAL INSTALLATIOW PREBORE THE NAIL GEILIN6 JOIST TO PARALLEL RAFTER (FACE-NAIL) SEE PAGE 6-005 EACH LAP 0 04 "SIMPSON" HDQB FOR ROOF SLOPES UNDER 5:12 WITH • • • HOLES,SET NEW MEMBER. O COm '� HOLDOWN ANCHOR ® 2-Ibd COMMON �, � 2•-16d COMMON LOCATIONS NOTED NAILS ® 6" O.G. 4 ROOF SPANS OF 28 OR GREATER, • • • +J „ 4.NO MIXING OF NAIL SIZES OR TYPES ALLOWED GEILIN6 JOIST LAPS OVER PARTITIONS (FACE-NAIL) SEE PAGE 0-005 EACH LAP 0 N O CD NAILS ® 6 O.C. 4 ,� USE 4 8 d COMMON NAILS ® EA. � / G�" O.G. IF BLOCKED ON PLANS _,--'loll O.G. IF BLOCKED ` ,„ . •- • • Q fl O GeORNER POST CORNER POST "" "" END OF STRAP. IE5 ?" 5.SEE SECTION 6 FOR ANY REOT TO CLINCH THE NAILS(TO r— ." TIGHTLY BOND THE END OF THE NAIL TO A 90" ANGLE,SEE COLLAR TIE TO RAFTER (PAGE-NAIL) SEE PAGE 6-005 PER TIE THE ABOVE ASSUMES A RAFTER GRAPHIC BELOW) "SIMPSON" HDQS 5PAGIN6 OF 16" O.G.; FOR SPACIN65 b,DIMENSIONS ARE DERIVED FROM THE NDS COMMENTARY BLOGKIN6 TO RAFTER (TOE-NAIL) 2-8d COMMON EACH END HOLDOWN ANCHOR ® SECTION 12.4-PLACEMENT OF NAILS $ SPIKES 4 TABLE LOCATIONS NOTED a OF 24„ O.G., INCREASE NAILING BY A GR 4-I. W ON PLANS ° ° FACTOR OF 1.5. RIM BOARD TO RAFTER (END-NAIL) 2-I6d COMMON EACH END (D CONNECTION BI 52 WAEE FRAMING AT RAFTER TO TOP PLATE TO STUD HOLDOWN INSTALLATION OPTIONS: CONNECTION: / • FOR NEW P. GONG. FOUND.'s 'r O FOR STfRAP - 3 8 d* COMMON NAILS ® EA. TOP PLATE TO TOP PLATE (PAGE-NAIL) 2-I6d COMMON ' PER FOOT HOLDOWN CAST IN PLACE w/-1/5"O THREADED ROD - END OF: STRAP. . • U ■— ✓'�W • TOP PLATES AT INTERSECTIONS (PAGE-NAIL) 4-I6d COMMON JOISTS - EA. SIDE FOR EXIST, P. GONG. OR NEWLY CURBED FOUND.'s `' . s� WdHEN IN TOWN OF ISLIP OR NAILING "I/8"O THREADED ROD (PRE-DRILLED) EMBEDDED 12" INTO NOTE 63EOMETRY EXCEEDS THAT PERMITTED IN CONCRETE w/ "SIMPSON" SET (HIGH STRENGTH EPDXY ----I B� MIAX. NAILING GRID ABOVE UTILIZE ,/ • • STUD TO STUD (FACE-NAIL) 2-I6d COMMON 24" O.G. M ADHESIVE), 4 FOR TEMP.'S O°F-40°F USE "SIMPSON" AT 1 S1,IMP50N #H2A (OR EQUAL) RAFTER TIE (HIGH STRENGTH ACRYLIC ADHESIVE) HEADER To HEADER (PAGE-NAIL) I6d COMMON IV' O.G. ALONG EDGES • • FOR TO>ENAILING - 3 8 d COMMON NAILS �•"```~"•"... r FOR, EXIST. /NEW G.M.U. (GONG. BLOCK) TOP or BOTTOM PLATE TO STUD (END-NAIL) SEE PAGE 5-005 PER STUD —1.— FILL TOP 2 COURSES SOLID 4 CAST IN PLACE HOLDOWN USE SAME w/7/8"� THREADED ROD CONNECTION "" --_","„ FOR G.,J. TO R.R. - Q 16 d COMMON NAILS r 1 REQUIREMENTS FOR "" -"-...... BOTTOM PLATE TO FLOOR JOIST, BAND JOIST, 2-I6d COMMON 12 PER FOOT RAISED G.J.'s(WHEN AT G.J. TO G.J. CONNECTION: ENDJOI5T, or BLOCKING (FACE-NAIL) APPLICABLE) FOR EAR. PLATE TO STUD ABOVE 8 OR BELOW HOEDOWN �G HOEDOWN 'D' 2 I6 d COMMON NAILS FOR G.J. TO G.J. - Of 16 d COMMON NAILS FLOOR FRAMINO • — Q Cn FOFOUNDATIONST \ FOR NEWLY POURED CONNECTION GI G2 • JOIST TO SILL, TOP PLATE or GIRDER (TOE-NAIL) 4-8d COMMON PER J015T n, FOUNDATION ® ONE STORY ONLY� ; Qm W (5) 2x FULL ENDWALL BRIDGING TO JOIST (TOE-NAIL) 2-5d COMMON EACH END Q HEIGHT STUD CORNER STUD ONNEGTED TO BLOCKING TO JOIST (TOE-NAIL) 2-8d COMMON EACH END TRANSFER SHEAR AT STUD TO FLOOR ASSEMBLY "SIMPSON" HDQB (5) 2x FULL ° BLOCKING TO SILL or HOLDOWN ANCHOR ® � 2-I6d COMMON HEIGHT STUD " w.- ""M G2 """'""" TO 5TUD CONNECTION: 5-I6d COMMON EACH BLOCK LOGATION5 NOTED NAILS ® 6' O.G. 4 �.---' TOP PLATE (TOE-NAIL) ON PLANS 10" O.G. IF BLOCKED G I ° FOR STRAP - 3 5 d* COMMON LEDGER STRIP TO BEAM (FACE-NAIL) 5-I6d COMMON EACH JOIST CORNER POST ° NAILS ® EA. END OF STRAP JOIST ON LEDGER TO BEAM (TOE-NAIL) 5-8d COMMON PER JOIST ° FOR EA. PLATE TO STUD ABOVE R OR 2-I6d CC N MC N " " ° BELOW - 2 16 d COMMON NAILS BAND J015T TO J015T (END-NAIL) 5-I6d COMMON PER JOIST NAILS ® O.C. BAND JOIST TO SILL or TOP PLATE (TOE-NAIL) 2-I6d COMMON PER FOOT ° a ROOF 5HEA7HINO STRUCTURAL PANELS: INTERIOR ZONE 8d COMMON 6" EDGE / I2" FIELD "SIMPSON" ST 5LOGKIN6 PERIMETER EDGE ZONE 8d COMMON 6 'EDGE / 6 FIELD HOEDOWN INSTALLATION OPTI0 ® EA.BAY a DI4RJ CONNECTION DI D2 soup &ABLE ENDI^IALL RAKE OR RAKE TRUSS w/ 8d COMMON 4" O.G.1� FOR NEW P. GONG. FOUND.':3 UP TO 9" RAKE OVERHANG „„„-„-..--•^"" HOLDOWN CAST IN PLACE w/-TIV0 THREADED ROD • FOR EXIST. P. GONG. OR Nf_l^1LY CURBED FOUND>.'s " : • AT 57UD TO FLOOR ASSEMBLY TO SILL GE I E I NO SHEATH I NO 7/8"m THREADED ROD (PRE-DRILLED) EMB3EDDED 12" INTO PLAT'E(S) CONNECTION: D2 CONCRETE w/ " PSC>N" SET (HIGH STRENGTH EPDXY F2ROMIN• ~----- -~'� GYPSUM WALLBOARD 5d COOLERS -1" EDGE / 10" FIELD ADHESIVE), 4 FOR TEMP.'s O"F-40°F USE ":SIMPSON" AT (HIGH STRENGTH ACRYLIC ADHESIVE) CORNER ° FOR 57RAP - 5 5 d* COMMON NAILS ® EA. ON #4REOR D I `^ ° END O1F STRAP (WRAP STRAP UNDER SILL PL) SPECIFIEDL__�� WALL SHEATHI NO FOR EXIST. /NEW G.M.U. (GONG. BLOCK) TYP. FOUND. NOTE ,� • FILL TOP 2 COURSES SOLID 4 CAST IN PLACE HOLDOWN o ° FOR ESA. PLATE TO STUD ABOVE 4 OR BELOW - w/1/5"O THREADED R.OD 2 I6 d COMMON NAILS h STRUCTURAL PANELS 8d COMMON 6" EDGE / 12" FIELD ALTERNATE CONFIGURATION - ABOVE STUD TO 6YP5UM WALLBOARD 5d COOLERS '7" EDGE / 10" FIELD ° FLOOkZ CONNECTION w/ # LPT4 SIMPSON (OR -_--•-- STRAP w/(3) Z �, ° """ 8d NAILS m EA.END N L I NcO/STRAFF I NO @ W 1 NDOW/DOOR HEADER STANDARD/ALTERNATE EQUAL,) ® PLATFORM TO SILL PLATES �`"~- .""" OF EA.STRAP TO R EA.JOIST-(FOR FLOOR SHEATHINO (SUBFLOOR) 2 ALTERNATE USE 0 SIMPSON H2.5A) U NOTATION: STRUCTURAL PANELS: lA - NUMBER OF Sd NAILS ® EA. END OF STRAPPING (2024 WFGM, TABLE 5.1,P. IbcQ;WHEN STRAPPING GONNECTI ON E I" or LE55: 8d COMMON b" EDGE / 12" FIELD REQUIRES OVER 14 NAILS, USE 51MPSON 0516 STRAPPING (OR EQUAL). "" � " ",-,„"...••••"•••„""'""„�� � GREATER THAN I": IOd COMMON 6" EDGE / 12" FIELD fB - NUMBER OF SILL STUDS-ON FLAT (DOES NOT APPLY To DOORS) (2024 WFGM,TABLE 5.255,P. 2dM) .- CG - NUMBER OF FULL HEIGHT KING STUDS ® EA. SIDE OF HEADER (2024 WFGM,TABLE 5.25C, P. 2a8 „„„. -"~""""" • ALTERNATE AS PER TABLE 3.250,P. 294) NAILING REQUIREMENTS ARE BASED ON WALL SHEATHING NAILED 6" O.G. AT THE PANEL EDGE. W A D >n - NUMBER OF I6d NAILS, END-NAILED THROUGH ADJACENT KING STUD TO END OF HEADER® EA. SIDE AT STUD TO FLOOR ASSEMBLY TO SILL ALTERNATIVE NAILING SCHEDULES SHALL BE USED WHERE WALL SHEATHING NAILING 15 REDUCED. a (2024 WFGM, TABLE 5.1,P. 1541) ° FOR EXAMPLE, IF WALL SHEATHING 15 NAILED 5" O.G. AT THE PANEL EDGE TO OBTAIN IHI&HER fE (2-PLY) - NUMBER OF JACK STUDS ® EA. END OF 2-PLY HEADER (2024 WFGM, TABLE 5.22F,P. 2414) ° PLATES) CONNECTION SHEAR CAPACITIES, NAILING REQUIREMENT5 FOR STRUCTURAL MEMBERS SHALL BE DOUBLED, OR C fE (5-PLY) - NUMBER OF JACK STUDS ® EA. END OF 5-PLY HEADER(2024 WFGM,TABLE 5.22F,P. 2114) °° a ° °Q SLAB ON GRADE APPLICATION: ALTERNATE CONNECTORS SHALL BE USED TO MAINTAIN THE LOAD PATH. fF - NUMBER OF I6d NAILS, END-NAILED THROUGH ADJACENT JACK STUD TO END OF SILLS) ® EA. SIDE :: ° ° ° a ° ° - WHEN WALL SHEATHING 15 CONTINUOUS OVER CONNECTED MEMBERS, THE TABULATED NUMBER OF PROJECT: E (DOES NOT APPLY TO DOORS) (2024 WFGM,TABLE 5.b, P. lal) " ° * NAILS SHALL BE PERMITTED TO BE REDUCED TO I-16D NAIL PER FOOT. FOR STRAP - 3 8 d COMMON NAILS ® EA. 5 - FOR ROOF SHEATHING WITHIN 4' OF THE PERIMETER EDGE OF THE ROOF, INGLUDIN6 4' ON EACH ".~ """" ae ° END OF STRAP (WRAP STRAP UNDER SILL PL.) SIDE OF THE ROOF PEAK THE 4 PERIMETER EDGE ZONE ATTACHMENT REQUIREMENTS SHALL BE - � MICHALECKO FASTENING 5GHEDULE B ° ° a a F ROUGH OPENING FRAMING REQUIREMENTS FOR WINVOW/DOOR OPENINGS " """~"...," ° a° ° 9° FOR EA. PLATE TO STUD ABOVE 4 OR BELOW - USED. REPAIRS (IN ACCORDANCE WITH WOOD FRAME CONSTRUCTION MANUAL 2018 EDITION) " """ .� 2 16 d COMMON NAILS A MAX NOTATION E E S I O NAO E FOR TRUSS T)'FE, FRE—ENO I NEERED ROUGH A B G D (2-PLY (3-PLY F WOOD, AND/OR TIMBER 0ON5TRUCTION OPENING HDW HDR) THE FOLLOWING SIONASE SHALL BE AFFIXED TO THE ELECTRIC METER BOX ATTACHED 11175 OLD SOUND AVE. 2'-O" 2 1 1 2 1 n/A 2 TO THE EXTERIOR OF STRUCTURE OR AFFIXED TO THE EXTERIOR WALL OF THE MATT ITUCK, NY 11952 RESIDENTIAL STRUCTURE AT A POINT IMMEDIATELY ADJACENT TO THE ELECTRIC BOX OR 4'-o" 5 1 2 5 1 n/A 3 SQL C I NO O TOfiL_ T OABLE ENDWALL A LOCATION LIKELY TO BE SEEN BY FIRST RESPONDERS WITH APPROVAL BY THE 5RACINO/57RAFFINO AUTHORITY HAVING JURISDICTION: DRAWING TITLE: * - PROVIDE (2) 2"xl0" HDR (MIN) U.O.N. 6'-0" 4 2 3 4 I n/A 4 TOP PLATE FOR RAKES 12"OR HOLDOWN ANCHOR BOLT BLOCKING 2 LESS PROVIDE � , at oil 6 2 5 5 1 n/A 5 }— SPLICE --} TOP PLATE SPLICE REQUIREMENTS TOP PLATE SPLICE REQUIREMENTS BAYS BACK® <TO LOGKIN6 m 12"o.G. CONSTRUCTION TYPE DESIGNATION SIHALL LENGTH I 4'-0" O.C. AGHEIVE RAKE O.H. BE "1" "11" "III" "IV" oR "V" TO INDICATE STRAPPING, & NAILING DETAILS FOR WIND - EXPOSURES B$0 - FOR WIND - EXPOSURES B$C - 10'-0" -1 n/A 4 6 2 n/A n/A ALL OTHER GASES ONE STORY SLAB ON &RAVE ROOF THE CONSTRUCTION CLASSIFICATION OF FASTENING SCHEDULE THE STRUCTURE UNDER SECTION 602 OF 12'_0" 8 n/A 5 8 2 n/A n/A BUILDING MINIMUM SPLICE BUILDING MINIMUM SPLIGE'�'` I THE NYS BG. DIMENSION (FT) LENGTH (FT.) DIMENSION (FT.) LENGTH (FT.) TYP. STRAP w/(5) PAGE: 8d NAILS EA. END DESIGNATION FOR STRUCTURAL 12'-O" 2'-O"/2'-6" 12'-o" 5'-O" OF EA. STRAP 6" DIAMETER COMPONENTS THAT ARE OF TRU55 TYPE, G ATTIC PRE-ENGINEERED WOOD, OR TIMBER G-003m00 ANCHOR BOLT SFE� 1 CAT ONS I6-O 5-O /5—a I6-o 4—o CONSTRUCTION AS FOLLOWS: 20'-O" 4'-O"/5'-O" 20'-O" 5'-O" 1 � - "F" = FLOOR FRAMING, INGLUDIN6 BLOCKING 2 BAYS ° =s., GIRDERS l$ BEAMS 6'-12 SPECIFICATION (2024 WFGM TABLES 5.2A 4 5.25, P. 151-I60) 24'-0" 4'-0"/5'-0" 24'-0" 6'-o" BACK ® 4'-0" o.G. "',, - "R" = ROOF FRAMING CORNER s2°— ;:- - "FR" = FLOOR 8 ROOF FRAMING DATE: 04/29/26 3 OF 6 CONDITION FOR ALL STRUCTURES: 5/a"0 ANCHOR BOLTS ® 52" O.G. 28'-O" 5'-O"/6'-5" 28'-O" 'i'-O" ' 2'-O" 6'-O"/"7'-b" 52'-O" 8'-O"5 iv SECOND FLOOR Q -i'-o"/8'-a" NOTES: I.TABULATED SPLICE LEN6TH5 ASSUME TOP PLATE-TO-TOP PLATE CONNECTION U51N6 2-I6d NAILS PER FOOT.FOR SHORTER SPLICE LENGTHS,THE NAIL 5PAGIN6 SHALL BE REDUCED IN ORDER TO 40-0 8-O /10-O 40-0 I I-O 1. MIN. -7„ EMBEDMENT INTO CONCRETE PROVIDE AN EQUIVALENT NUMBER OF NAILS BLOCKING 2 BAYS END w/ 5" SQUARE WASHERS AND END NUT SETUP; BACK ® 4'-O" O.G. 2.TABULATED SPLICE LENGTHS ASSUME A BUILDING LOCATED 50'-O" 10'-O"/12'-6" 50'-O" I5'-O" "•`.. r ' CONDITION 15" EMBEDMENT FOR G.M.U. (BLOCK) FOUND. 8 FILL IN EXPOSURE B TYP. STRAP w/(5) STROKE r fi: N II ,: 1, II ti TOP TWO COURSES SOLID D 3.TABULATED SPLICE LENGTHS ARE BASED ON b FOOT WALL 601-0 12-OI/IS-O bOI-O I61-OI' OF EA. STRAP :p HEIGHTS FOR OTHER WALL HEI6HT5,H,THE TABULATED UNIT �. 2. ANCHORS NOTED HEREIN ARE NOT TO BE USED FOR LATERAL LOADS SHALL BE MULTIPLIED BY H/5; FIRST FLOOR PLAN DIAGRAM OF ZONE=5 OR REPLACED BY HOLD DOWNS FOR SHEARWALLS FOR ALTERNATIVE WALL HEI&HT5 MULTIPLY THE ABOVE -10-O I4-O '70-0 19-O NOTED MIN.SPLICE LENGTH BY THE FOLLOWIN6 FACTOR 5. ANCHOR BOLTS ARE TO BE BETWEEN 6" $ 12" (ADDITIONALLY,ROUND UP TO THE NEAREST FOOT). „ „ „ , N U 80-O 16-O 80-O 22-O FROM ENDS AND CORNERS (TWO ® CORNERS) q'WALL - 1.125 REFLECTIVE REFLECTIVE (SEE DIAGRAM TO LEFT) 1O'WALL- 1.25 BLOCKING 2 BAYS n'WALL - 1.5?5 RED PANTONE WHITE THIS COLUMN w/MULTIPLIER BACK® 4-O" O.G. 4. COORDINATE w/ HOLDOWN LOCATIONS 12'WALL - 1.5 FOR 10'-0"WALL #187 4.TOP PLATES SHALL BE A MINIMUM OF STUD &RAVE MATERIAL MISCELLANEOUS FRAMING GRAPHICS CONTINUOUS BUILT-Ufi ORDERS, 5 OR MORE SUPPORTS (THAT EXCEED FRAMING STANDARDS, IT 15 REQ'D FOR FRAMER TO HA\/E A REBLOCXK NCB FOR PLATFORM NOOD FRAM 1 NC WORKINO KNOWLEDGE OiF THE AMERICAN WOOD COUNCIL [AWC] DETAIL BOOK CONNECTION PATTERN SCHEDULE AND ALL RELEVANT PORTIONS OF THE RESIDENTIAL CODE) BETWEEN 1/6 ASSEMBLY REQUIREMENTS: (FOR ENGINEERED LUMBER [Ic. WOOD I-JOISTS] SEE MANU. 5PEG.'5 FOR ADDITIONAL INFO.) a CONNECTION 6 1/4 OF A WHEN GIRDERS MADE UP OF JOISTS NAILED Q BLOCKING UNDER LOAD BEARING WALL PATTERN DESCRIPTION TOGETHER SIDE BY SIDE ARE CONTINUOUS OVER THREE OR MORE SUPPORTS, JOINTS ARE TO BE I. FOR PLATFORM FRAME CONSTRUCTION: THE SOLE SERVES NON-LOAD 5EARIN6 WALL OFFSET FROM SUPPORT MAx. 32" LOCATED BETWEEN ONE SIXTH AND ONE QUARTER AS FIRE-5TOPPIN6. LuLLI A (2)ROWS IOd NAILS m 12"O.G. P THE SPAN LENI6TH FROM AN INTERMEDIATE ui 2. FOR PLATFORM FRAME CONSTRUCTION: THE DOUBLE JOIST -i co STUD SUPPORT. NO 'TWO ADJOINING JOISTS, NOR MORE SERVES AS FORM FRPING. N TUDS SUBFLooR B (3)Rows 1oa NAILS• 12"O.C. P, THAN ONE THIRD THE TOTAL NUMBER, ARE TO BE SU$FLOOiR G (2) ROWS I/2" BOLTS m 12"O.G.STAGGERED; JOINTED ON TIHE SAME SIDE OF THE SUPPORT. S. FOR PLATFORM FRAME CONSTRUCTION: THE SOLE AND DOUBLE �� L0 DEL.® ENDS TWO-PIECE �; SOLE PLATE BUILT UP GIRDER P MAX.52" NAILING: PLATE SERVE AS FIRESTOPPING. D (2)ROWS 1/2" m BOLTS a 16"O.G. SOLE PLATE TWO-PIECE 67IFRDER5 ARE TO BE NAILED FROM ONE 4. FOR PLATFORM FRAME CONSTRUCTION: THE DOUBLE — Q E (2)ROWS I/2" m BOLTS m 24"O.C. SIDE WITH IOdI NAILS, TWO NEAR EACH END OF JOIST SERVES AS FIRESTOPPIN6. a--+ >- C� BETWEEN 1/6 EACH PIECE, OTHERS STAGGERED WITH A DISTANCE F (2)ROWS 3-3/8"TRUSSLocK SCREWS a 12"O.c. a 1/4 OF A OF I6 INCHES !BETWEEN NAILS IN A HORIZONTAL r✓- 5. FIRE5TOPPIN6 SHALL BE 2 INCHES OF WOOD BLOGKIN6 O C (U z O SGREweD ON(I)SIDE of MEMBER OR OF NONCOM-BUSTIBLE FILL. IZ 1 LINE; OR GIRDPER5 ARE TO BE NAILED FROM EACH •C6 Y (2)ROWS 3-5/8"TRU55LOOK 50REwS a 16"O.G. p G SIDE , NAILS, TWO NEAR EACH END OF EACH b FOR PLATFORM FRAME CONSTRUCTION THE SOLE c 2 X � CV SCREWED ON(U SIDE OF MEMBER JOIST, OTHH . :ERS STAGGERED w/ A DISTANCE OF 32" AND 2 INCHES OF WOOD 5LOGKIN6 PLACED BETWEEN O 4- 1 H (2)ROWS ON(1) TR1E OF MEMBER SCREWS® 24"o.c. BETWEEN NAILt5 IN A HORIZONTAL LINE. JOISTS SERVE AS FIRESTOPPIN6. O O C9 JOIST SCREWED ON(I)SIDE OF MEMBER P O m N r-- MAXIMUM OFFSET (2)ROW5 5"TRUSSLOGK SCREWS a 12"O.G. THREE-PIECE a_J cu Ln "(. FOR PLATFORM FRAME CONSTRUCTION: THE SOLE AND N JOIST DEPTH, d SCREWED ON BOTH SIDE OF MEMBER BUILT UP GIRDER MAX.32" THREE-PIECE Cf IRDERS ARE TO BE NAILED w/ 20d C O 2 INCHES OF WOOD BLOCKING PLACED BETWEEN JOISTS O MATCHED SIZE OF BLOCKING P NAILS ON EA. '.SIDE w/ TWO NEAR EA. END OF EA. Q d O UNDER NON-LOAD BEARING FIRE5TOPPIN6 AND K (2)ROWS 5°TBOTH SIDE SCREWS m I6"O.C. q SERVE AS FIRESTOPPIN6. BLOCKING SCREWED ON BOTH SIDE OF MEMBER PIECE, INGLUDIING INTERMIDIATE JOINTS, AND w/ THE PARTITIONS 032 O.C:. STUD (2)Rows 5"TRU55LOGK SGREwS m 24"O.G. BETWEEN 1/6 OTHERS 5TAOrSERED w/ A DISTANCE OF NOT MORE 3 5. THE HEADER SERVES AS FIRE-5TOPPIN6. DOUBLE PLATE L SCREWED ON BOTH SIDE OF MEMBER a 1/4 OF A THAN 52" BETMEEN NAILS IN A HORIZONTAL LINE. 9. TWO-INCH WOOD BLOCKING OR THE EQUIVALENT SHALL FOUR-PIECE 5�IDER5 ARE TO BE A55EMLEM AS BE ADDED BETWEEN STUDS IN PARTITION ADJACENT TO GE I L I NG BRAG I NG o P 5TRIN6ER TO SERVE A5 FIRE5TOPPIN6.GANTI LEVERED FLOOR. I.BEAMS d HEADERS NOT NOTED WITH CONNECTION PATTERN ON SHOWN, AND NAILED w/ 20d NAILS AS SPECIFIED � GABLE ENDWALL PLAN SHALL USE CONNECTION PATTERN 'A'WHEN 6"OR SMALLER FOR THE THREE-PIECE GIRDER. 3 CONNECTION PATTERN 'B'WHEN 10"OR LARGER P 10. THE SPACE BETWEEN A CHIMNEY AND COMBUSTIBLE FLOOR FRAMING SHALL BE FIRESTOPPED AT THE BOTTOM WITH .,STUD 2.WHEN FASTENERS 1/ NAILING FROM BOTH SIDES OTHER MEMBER- FOUR-PIECE ANCHORING: 2 APPROXIMATELY I-INCH DEPTH OF NONCOMBUSTIBLE MATERIAL OFFSET FASTENERS 112"FROM ONE SIDE TO THE OTHER BUILT UP ORDER P GIRDERS ARE TO BE SECURELY ANCHORED TO HELD IN PLACE BY METAL LATH OR WIRE FABRIC. SUCH t , SOLE PLATE GABLE END I FIRESTOPPIN6 SHALL NOT BE REQUIRED WHEN THE BOTTOM OF T SUBFLOOR / LATERAL BRACE® 6'O.G. T�55 MASONRY PIERS, NAILED TO WOOD POSTS OR THE VERTICAL OPENING 15 SEALED BY PLASTER ON THE GEILIN6 BAND BOLTED TO 57EEL COLUMNS. JOr , (2) IOd NAILS TRUSS OR AND CHIMNEY. THE SPACE ABOVE THE FIRE-5TOPPIN6 SHALL BE U LEFT UNFILLED 50 THAT HEAT FROM THE CHIMNEY CAN BE CARRIED C.J. AWAY BY AIR CURRENTS MOVING UPWARD AND OUT THROUGH NORMAL C�J G, PLATFORM FRAME CONSTRUCTION SHRINKAGE CRACKS OF THE INTERIOR FINISH. PLASTER GEILIN6 ON ( —A 10) 8d N A I L I N C �A TTE RN S FOR S 1 D E LOADED BEAMS (i e. FLU✓ I B F_A M✓) -LOCATIONS REOUIRUN6 FIRE5TOPPIN6- NONCOMBUSTIBLE LATH,EXTENDING TO CHIMNEY FACES, WILL SERVE (LTL NAILS AS FIRESTOPPIN6. e FIRE- FIRE- WOOD FIRESTOPPING FIRESTOPPING FASTENING RECOMMENDATIONS FOR SIDE-LOADED, STOPPING SOLE + STOPPING FIRE- FIRE- MULTIPLE-PIECE MEMBERS STOPPING STOPPING JOIST " 5d COOLER NAILS o 10" O.G. NAILED' BOLTED' ` I I1 I,N, VERTICAL 2"x4" BLOCK NAILED TO EA.BRACE rsLOCKIMIG 2 ROWS Ibd s ROWS IbdL2 Rohg14' 2 ROW51�' 2 ROW514" w/(4) IOd NAILS COMMON COMMON osTe eAes2ErP COVERING 15 APPLIED e 12,O.G.' a 12'O.G.6 a 12'LOG. BOLTS 6 O.C. ' FIREST 15 AP LIM STUD 6YPSUM BOARD 20 ga. STRAP TWO ROWS 12"O.G. THREE ROWS 12"O.G. TO UNDERSIDE Or- DOUBLE PLATE * 5d COOLER NAILS a IO" O.C. (10)ad NAILS BEAM SELECTION 1-4/ STD. NAILING LOCATION I LOCATION 2 LOCATION 3 LOCATION 4 JOISTS V J NOTE: END WALL STUDS AS NOTED IN NOTES '7 $ 8 ° ° ° ° 5 NONCOMBUSTIBLE ALTERNATE JOIST SHALL BE LOCATED DIRECTLY * DENOTES ALT.FOR USE OF DRYWALL 50REW5 ° ° ° ° OVER STUDS,UNLE55 TOP PLATE 15 SOLE FIRESTOPPING LOCATION Q 4"o EDGE/ 12" ® FIELD FULLY BLOCKED 1.TOP AND BOTTOM ROWS SHOULD BE 2"FROM EDGES WOOD FIRESTOPPING DESIGNED TO CARRY THE LOAD SCREWS#6 - lY4"TYPE W OR 5 F1REsroPPING LOCATION 5 LOCATION 6 RDIER 2.BOLT HOLES ARE TO BE THE SAME DIAMETER AS THE BOLT AND SHOULD BE LOCATED 2" TWO ROP6 24"O.G.STAGGERED TWO ROWS 6"O.G. FROM THE TOP AND BOTTOM OF THE MEMBER.EVERY BOLT MUST EXTEND THROUGH THE FULL INTERIOR STUD DETAIL THICKNESS OF THE MEMBER USE WA514ERS UNDER HEAD AND NUT. O o o o 0 0 0 0 0 OVERLAID ROOF B.STAGGER EACH ROW OF FASTENERS BY 12'. O 0° 2'SPACE NOT 4.FOR A THREE-PIECE MEMBER THE SPECIFIED NAILING 15 FROM EACH SIDE.ATTACHMENT © VALLEY III TO BE FILLED 11 \ ® NONCOMBUSTIBLE FIRESTOPPING S.FOUR-PIECE MEMBERS SHOULD ONLY BE USED WHEN LOADS ARE APPLIED TO I FIRESTOPPIN6 APPROX.I INCH THICK BOTH SIDE OF THE MEMBER 6.VALUES FOR NAILING CONNECTIONS MAY BE DOUBLED FOR 6'O.G.OR TRIPLED FOR 4"O.G.NAIL SPACING. LOCATION ? STD.NAILING FOR TOP LOADED MULTIPLE-PIECE BEAMS: �\ STRAPPING w/ ?.2 ROWS OF Ibd COMMON NAILS(12"O.C)FOR DEPTHS 12"OR LESS FIRESTOPPIN6 \ 4 8d NAILS LOCATION 8 LOCATION cl m EA.END a R.R. 6.5 ROW5 OF Ibd COMMON NAILS(12"O.W FOR DEPTHS OF 14',16'd I5". LOCATION 10 FULL WIDTH 6,zz;� 2" BLOGKIN6 ZO M, w CONSTRUCT ON DETAILS N ND LOAD PATH CONNECT ON DETAILS TOP PLATE: DRILL 2110 INTO ROOF DECK FOR STRAPPING INSTL. NOT TO SCALE INTERSECTION DETAIL EXIST.OR NEW NEW R.R.SET w/ R.R.BELOW UPPER TOP PLATE LAPS 4 IOd IN ,CONTINUOUS LOWER TOE NAIL TOP PLATE NOTED CONT.BLOCKING SPIKED TO R.R.'s ALIGN NEW d EX. R.R. AS SHONG STUDS PLAN VIEW WN KI NOTE: SIMILAR® 'SHED' WOOD JO I S ROOF,R.R. IN LINE WOOD JO 1 CRIPPLE STUD BLOCKING JO 1ST HANGE HEADER GENERAL REIOU I REMENTS FO'R GENERAL REQUIREMENTS FOR z INSTALLATION OF CLINCHED NAILS INSTALLATION OF TOE-NAILS GIRDER/HEADS � JACK STUDS � WOOD GIRDER WOOD JOIST MAIN MEMBER i�o O JOIST FRAMING OVER WOOD GIRDER JOIST FRAMING FLUSH WITH GIRDER/HEADER TYP I GAL HEADER CONNECTION I. TOE-NAIL5 SHALL BE DRIVEN ® AN ANGLE OF PROJECT: MEMBERS DIAM.X s APPROX. 30° w/THE MAIN MEMBER b STARTED APPROX. I. NAILS SHALL BE DRIVEN PERPENDICULAR TO ks THE LENGTH OF THE NAIL FROM THE MEMBER END, AS SHOWN ABOVE M I C H A L E C K O THE MEMBER, STRAIGHT THf•:000H AND BENT OVIER A MIN. OF (5) NAIL DIAM.'s AT A 0I0° ANGLE 2. THE MIN. PENETRATION OF THE NAIL IN TO THE MAIN MEMBER, FOR THIS APPLICATION, SHALL BE AT LEAST RAFTER REPAIRS SIX TIMES THE DIAM. OF THE NAIL O, No MORE THAN 2 TOE NAILS SHALL BE 5. INSTALLED AVOID TALLED IN EA.INSIDE OF A RAFTER OR CEILING JOUST WALL STUD WALL STUD WHEN FASTENED TO A NED TO TOP PLATE 3 TOE NAILS BOTTOM PLAT BOTTOM PLAT 11175 OLD IN EA. SIDE WHEN FASTENED TO A 2"xb" TOP PLATE. BATHTUB SUB FLOOR SOUND AVE. DOUBLE JOIST --0 DOUBLE JOTS TOP PLATE MATTITUCK, NY 11952 CH I M. CHASTE SECURING ® STD. SIDE WALL DRAWING TITLE: WALL STUD FRAMING GRAPHICS BEAM CONNECTION PATTERNS FIREBLOCKING DETAILS (51M. ® CHASE WITHIN PLANE OF ROOF DOUBLE JOIST FOR UNDER A BATHTUB ALL BATHROOMS WITH TILE FLOOR DOUBLE JOIST FOR NON-BEARING WALLS ALTERNATIVE RAFTER TO WALL STUD CONNECTION w/57UD5 TO ATTIC, FLOOIR $ BLK'G TO R/L 5IDE5 w/5TRAPPIN6 TO R/L SIDES) UNDER K 1 TGHEN FLOORS AND RADIANT FLOORS W 1 TH MUD. O TQP PLATE ® GHIM. CHASE WALL �o W ND RE'5 STANT CONSTRUCT ON CONNECTORS PAGE: �� U CONNECTION LOC A,TI ON: PART NUMBER: NOTES: G-004mOO RIDGE-TO-RAFTERS C520 © 21" APPLY TO EACH PAIR OF RAFTERS Q10-z� ® RAFTER-TO-WAILL H7 APPLY TO EACH RAFTER DATE: 04 29 ROOF o z / /26 4 0 F 6 r, o RAFTER-TO-PLAtTE H8 or H2.E APPLY TO EACH RAFTER z_ REO'D BLACKING p • ii TO ALIGN w/STRAPPING d PLATE-TO-WALL STUD G520 @ 18 APPLY TO EACH WALL STUD ® EA THE RST FI LEVEL FL ®z 2ND. FLOOR WALL-TO-IST. FLOOR WALL LFTA or G520 © 36" APPLY TO EACH WALL STUD FLOOR/CL6. ® O HEADER-TO-JACK STUD 05200 1211 APPLY TO EACH JACK STUD CRIPPLE STUD-TO-HEADER H3 APPLY TO EACH CRIPPLE STUD SHEAR WALL HOLDDOWIN ANCHOR SSTB 16 APPLY TO EACH S I DEWALL END "t WRAP UNDER DOUBLE SILL PLATE ', ' ' •.•._ IST. FLOOR-UNDER-SILL PLATE C520 ' SIDE VIEW FLAN VIEW (USE WITH 5" SOUARE WASHERS) 6 k; USE THE FOLLOWING OR APPROVED SIMPSON METAL CONNECTORS FOR PROPER WIND RESISTANT CONSTRUCTION. M FOLLOW MANUFACTURE'S RECOMEINDED INSTALLATION INSTRUCTIONS TO ACHIE\/E MAXIMUM UPLIFT LOAD CAPACITY. SE NE Al_ J I �550L < I : _ EXISTING TO BE DEMOLISHED j NEN TIAL HEI5HT V400 FRRAME (L.O. STL. WHEN APPLICABLE) a O EXISTING TO REMAIN Q --�.{ NEW FOUNDATION WALL NEW WOO FRAME (L.6. I- --=-i w W 5TL. WHEN APPD LICAB J C m LE) MIN. (2) 2"x4" STRUCTURAL _ cm NEW ElI-HR FIRE RATED POST FOR 4" WALLS Q c LID2xb WOOD FRAME (L.G. STL. (MIN. (2) " " STRUCTURAL P05T FOR 6" WALLS), U.O.N. 0 WHEN APPLICABLE) } 0 NEW 2-HR FIRE RATED z WOOD FRAME (L.6. STL. NE PLUMB W ING ALL L O C N W 0 WHEN APPLICABLE) a- � X U N O O O 't (� 14'-5" O m 4-J a--+ L!) FLOOR PLAN NOTES -I'-0y2" C N O cu .. WINDOW NOTE: 4'-1" 8'-10" EQ. EQ. 3'-�i" 2'-3" 3'-10" 3'-2" I X8" 4'-2" Q a O OI. ALL NEW WINDOWS SHALL BE ANDERSEN 100 SERIES X X X CASEMENT. INSTALL AS PER MANU. 5PEG.'S. 2.NOTE DOES NOT INDICATE EACH NEW WINDOW PROPO>SED; SEE DEVONATION5 4 WINDOW SCHEDULE. 15, " b'-O" 5.FOR SUBSTITUTIONS,SEE NOTE #cd IN "6LA55 WINDOWS - 7'O 5'-10" II1`11 AND DOORS" ON PAGE 6-002. ®® 4.ALL CASEMENT WINDOWS TO HAVE STRAIGHT ARM HIINOE. O EXIST. (V 5. ALL DOUBLE HUNG WINDOWS TO :BE TILT WASH GL. 6.IN GENERAL, TEMP. 6L. SHALL BE PROVIDED: O I O' 6.1. FOR ALL SKYLIGHTS 8 OPERABLE PANELS OF 2'-4" 110'-6" _ "RO �`ST X BEDROOM SWINGING, SLIDING, BIFOLD DOORS (V ry - I ® 1 J 6.2. WITHIN IV' OF F.F. u Y _ 6 '7� 6.5. WITHIN 24" OF A DOOR O O a 6.4. WITHIN STAIRWAYS d WITHIN 56" OF A LANDINd6 dJ 49 S.F. 6.5. WITHIN TUB/SHOWER ENCLOSURES 6.6. SEE ALSO GENERAL NOTE5 ON PAGE 6-002 O to-) -T. SEE PAGE 6-005 FOR FRAMING ELEMENTS AROUNDIWINDOW R S (TYP. FO ALL) U.O.N.;'PROVID EXIST. E AT A MINIMMJM ' • in ...�J (2) 2"xl0" HEADER U.O.N. ' �' Lb �; I 8.WINDOW FALL PROTECTION SHALL BE PROVIDED PER, X.OI X `fl X BEDROOM NY5 R521.2 FOR OPERABLE WINDOWS WITH SILL HEIOBHT5 • 106 S.F. H•W - XIS EXIST. DINING O poem Tu&N 24" ABOVE F.F.,THAT ARE MORE THAN-i:" =X EXIST. ABOVE GRADE vn :rrc o��c�:ur sURFAGE AT THE BASEMENT KITCHEN I ROOM 252 S.F. 203 S.F. I I67 S.F. Oi I X w BUILDING EXTERIOR. _ - w Q :t r 1 v ?-EXIST. UP 0. -ry ery wT6. to w X v i6 Q 6 4" GL6. EGRESS NOTE: NI� HGHT. COVE, E SECTION R510.2.1 THE FOLLC WINO MEANS OF w `fl I I `fl I Q EORE5S SHALL BE FOLLOWED: _ 'j 1K I t(1 �. �n+ /, EX_ T. W NET CLEAR OFF-NINO........... 5.1 S.F. 3'-O" 4'-5" (V I cV x 26'-3" X W EXIST. GL. N NET CLEAR HEIGHT............... 24" MINIMUM NET CLEAR WIDTH................. 20" MINIMUM 'I� Q NEW FLOOR (AS NEEDED): p O I'-2" V77�77 _ 5'-10" 5'-10" FEX.ATTIC, 2 - EXIST. UP - EXIST.- EXIST.- HATCH �' EXIST. 7� O 1. NEW J" PLYWOOD SUBFLOOR BENEATH (GLUE a SCREK4 m m GL. SCREW PERIMETER OF SHEATHING 6" O.G. d 12" O.G. a® 4D I I I B Q (13) RI ® L3:_3 _ GL. INTERIOR. m }'75 - EXIST. L - L 2.NEW FLOORING PER H.O. SELECTION - EXIST. EXIST. HEATING NOTE: u r I EXIST. HEADERS TO REMAIN UNLESS lu BEDROOM O I. NEW BASEBOARD HYDRONIC HEATING SHALL BE Z in I COMPROMISED. X 120 INSTALLED WHERE DAMAGED. xl x14 I EXIST. TRUE 2"x6" w OTHERWISE, NEW (2) 2"x10" HDR, 2.PRECISE PLACEMENT d' BASEBOARD LEN6TH5 SHALL Q F.J. ® Iq" O.G. A 5 '10" GL6 BE DESI6NED BY OTHERS. I iu ul ��l I rt1 I u� HOHT. HOLDOWN (FOUNDATION TO 15T' FLOOR- AS NEEDED): A-201 i- Q - A-2O1 i- EXIST-.RtOOMEAT A-2ol m 4D HOEDOWN 'D' A5 PER PAGE 6-0056 F w EXIST. EXIST. 2"x8" G.J. I 2 - HALLWAY N CRAWL SPACE N 0 2113 5.F. ' EXIST. A-201 XIo DW ® 16" O.G. C'f ly O 6"x6" F057 W COLUMN CASINO: 3 w Q� w Q EXIST. OIL w 3'-O" I6'-3"' -O° REPAIR DRYWALL 1. PROVIDE 6"xb" P.T. P05T INSIDE HB46 PERMAGAST' Q " BOILER LEXIST.O.C. (\ WALLS E GEID. A51 EXIST. TRUE 2'xb 4'-8" - � F.J. ® I6" .G. (VIF) f„ C'�- NEEDED. ` (OR EQUAL) COLUMN CASING. F.J. 0 I'll, O.G. (VIF) R OR RPR. AS NEEDED 17 GL6, w µ to 2. CONNECT P05T TO BEAM w/SIMPSON ACH6Z POST GAP RPL. AS NEEDED H46HT. - X (PROVIDE SHIMMING AS REO.'D TO MATCH BEAM WIDTH ( I O ~ F EXIST. 10" GL6 in A TO POST GAP WIDTH). 4D _ I B N REPAIR DRYWAlLL ® -�� HOHT. id O (t1 X WALLS d: CEILINc6 AS\ `Sly OIL. ® d m 5. WHEN F05T FALLS UPON GONG. SLAB, CONNECT F05T lu TO GONG. SLAB W ABUb6Z POST BASE $ PROVIDE 2" m m 1'-2" I'-3" NEEDED• in MIN. GONG. COVER ON ALL SIDES. V' N HOT WATER PIPING INSULATION: 5'-�:2 '� '� X MECHANICAL SYSTEM PIPING AND HOT V ATER PIPIN6 SHALL BE INSULATED TO AN R-VALUE OF NOT LESS THAN R-3 FOR THE FOLLOWING CONDITIONS PER 2020 NY5 EGG R405.4 d R40�3 5: - w - v O O O I. MECHANICAL SYSTEM PIPING CAPABLE OF CARRYING I n FLUIDS >105°F OR <55°F (R405.4) - 5 2. PIPIN6 J" AND LARGER IN NOMINAL DIAMETER )< EXIST. LIVING 5. PIPING SERVING MORE THAN (1) DWELLING UNIT � ROOM tEXIST.PORGH� X EXIST. 4. PIPING LOCATED OUTSIDE CONDITIONED SPACE - w - A-2o1 EXIST. 15I S.F. - ROOF TO BE I BEDROOM - 5. PIPING FROM WATER HEATER TO A DISTRIBUTION MANIFOLD O O 2 ( GOV. PORCH ! Q RE-SECURED 1 151 S.F. > 6. PIPING LOCATED UNDER A FLOOR SLAB cV EXIST, cr 73 S.F. - cV = \ N T. BURIED PIPING N p CRAWL SPACE V $. SUPPLY 4 RETURN PIPING IN RECIRCULATION 5Y5TEM5 XIQ w 7'll" GL6. X OTHER THAN DEMAND REGIRGULA710N SYSTEMS. ul m HOW. O X U w 5 � Lu HATCHED AREA. 5'4/2" EQ. X Eo. EQ. X M EO. INDICATES AREA OF NO WORK 3'-O" 6'-I" 14'-4" 3'-O" 6'-I" 14'-4" b'-1" 14'-4" PROJECT: FROF05E 7) FOUN1�)AT1 ON PLAN FROFOSEI) FIRST FLOOD' FLAN FROFOSF_r�) SEGOM7) FLOOR FLAN M ICHALECKO AFFECTED AREA APPROX. 267 S.F. SCALE: 114" = 1'-0" AFFECTED AREA APPROX. 267 S.F. SCALE: 114" = 1'-0" AFFECTED AREA APPROX. 267 S.F. SCALE: 114" = I'-O" REPAIRS 11175 OLD SOUND AVE. IN WINDOWS SHALL BE ANDERSEN 100 SERIES; IMI5TALL AS PER MANU. SPEC.'s. SEE PAGE "6-003" FOR NAILING 8 5TRAPPIN6 DETAILS. MATTITUCK, NY 11952 4 DOOR SCHEDULE FOR ALL GLASS DOORS FROV SAME MANUFACTURER tr\L DIMENSIONS FOR FRAMING OF WINDOWS TO B3E PROVIDED BY WINDOW MANUFACTURER 'TRACTOR TO VERIFY MANUFACTURER DIMENSIOtN WIDTHS FOR ALL MULLED WINDOWS DRAWING TITLE: W CHART PROPOSED PLANS EGRESS CLEAR LIGHT VENT ROUGH OPENING WINDOW DIMENSION OPENING PROV. PROV. TAG COUNT TYPE MULLED MODEL # WIDTH REOV: 20" TEMP. PER UNIT PER UNIT WIDTH HEIGHT ] WIDTH j HEIGHT OPEN REO'D: 5.17 S.F. A I MULLED F CASEMENT Q 2540-2 4'-6" 4'-O" 51-111/2, J 11.60IF 12.05 PAGE: B 2 � CASEMENT 2040:::][ 2'-0" 4'-O" I'-III/2" 3'-III/2' 4A4 5.1-1 A-10100 DATE: 04/29/26 5 OF 6 Y a ' r; , o- F� ELEVATION NOTES 12 I2 a Q �q q� Lu W HATCHED AREAS INDICATE AREA OF' REPAIR. W co 12 J O EXIST. PORCH ROOFING NOTE (A5 NE:EDED):I. SECURE EXISTING PORCH ROOF TO EXIST. HOME 4 Q N PROP OSED COLUMNS PER GENERAL 4 PLAN NOTES. 2.INSTALL NEW ASPHALT ROOF 5HINGLE5.. 5.INSTALL ICE AND P"IATER SHIELD FROM FASCIA UP TO O 24" FROM INSIDE FACE OF STUD WALL AND AT VALLEYS _O 4.INSTALL (1) LAYER OF 15# BUILDING FEL'.T UNDERLAYMENT .�' z o (OR EQUAL) FOR PITCHES OVER 4:12, AMD (2) LAYERS E:l FOP, O PITCHES FROM 2:12 TO 4:12, OVER: N ) 5. I/2" D GX PLYWOOL> SHEATHING (BLOCK ALL SEAMS) a- .� � � � 6.GAP 5HINGLE OVER RIDGE 4 HIPS (A5 IREOV) C X - N -1. FLASH ALL VALLEYS 1 0 O m Z Cfl B.INSTALL DRIP EDE'E AS REQ'D 9. INSTALL ALL AS PER MANU. SPEC.'S 4-1 N m --- -. -- - - -_-- --- —-- -- - - =-= = Q d O — O I. 5EE NOTE AT BUILDING SECTION FOR MINIMUM CONSTRUCTION STANDARDS 2. H.O. TO VERIFY FINAL COLOR AND MATERIAL SELECTION 4 BEFORE INSTALLATION 4 4 I n l OPROVIDE WD. FR. ??ALL INFILL ® OPE:NING / 3 / / w/ SIDING TO MATCH EXIST. 2 X LL IL X FRIEZE BOARD: B \ 3 \ / /(B/ O4 PROVIDE AT AFFECTED AREAS o X � J - TO MATCH EXISTINE3 T� 4 � 5 U . - O COLUMNS: A-2oi n1 PROVIDE (2) PER PLAN NOTES W FEAR ELEVATION (NORTH) LEFT ELEVATION (NEST) FRONT ELEVATION (SOUTH) SCALE: I/4" = I'-O" SCALE: I/4" = I'-O" 50ALE: 1/4" = I'-O" T'11 ALL NEW WINDOWS SHALL BE ANDERSEN 100 SERIES; INSTALL AS PER MANU. SPEC.'s. SEE PAGE "G-005" FOR NAILING 4 STRAPPING DETAILS. Q �JJ E,X15T. ROOFING + • SEE DOOR SCHEDULE FOR ALL GLASS DOORS FROM SAME MANUFACTURER FINAL DIMENSIONS FOR FRAMING OF WINDOWS TO BE PROVIDED BY WINDOW MANUFACTURER EXIST. ROOF ** CONTRACTOR TO VERIFY MANUFACTURER DIMENSION WIDTH5 FOR ALL MULLED WINDOWS CONSTRUCTION EXIST. RAFTER TIE. p�5?0L\0L�`N WINDOW CHART EGRESS CLEAR RAFTERN TIE ASEEDED. ��\b� �¢ LIGHT VENT ROUGH OPENING WINDOW DIMENSION OPENING PROV. PROV. TAG COUNT TYPE MULLED MODEL # WIDTH REQ'D: 20" EMP• PER UNIT PER UNIT I HEIGHT REO'D: 24" WIDTH HEIGHT WIDTH HEIGHT OPEN REQ'D: 5.1 S.F. A 1 MULLED Q 2540-2 4'-b" 4'-O" 4'-5 I/2" 3'-II I/2" I I b0 12.05 EX. RIDGE CASEMENT I EXIST. EXIST. G.J.. AS PER PLAN FA5GIA B 2 CASEMENT 2040 2'-O" 4'-O" I'-III/2" 3'-III/2" 4.�14 5.11 BOARD LIST . EXIST. BEAM AS EXIST. JdOI5T HANGERS. ATTIGZ PER PLAN NEW SIMPSON LU526 GALV. JOIST WANGER5 (OR BUILDING SECTION NOTES X. G.J. APPROVEL7 FEW AS NEEDED PROP. "SIMPSON" P064 (FOR 3 PLY I CEILING CONSTRUCTION (AS NEEDED): • 1/2" GDX PLYWD 5HEATHING (BLOCKING ® ALL PLYWD BM) SEAMS) "SIMPSON" 5052-2/4 . R.R., G.J., 4 G.T. A5 NOTED ON PLANS (® SPANS OVER (FOR 2 PLY BM) 8' INSTALL "X" BRIDGING ® CENTER OF SPAN,U.O.N.) LIST. • MIN. R-401 BATT INSULATION.(ONLY BETWEEN INTERIOR BED-` CONDITIONED AREAS AND EXTERIOR) ROOM %Z • PROVIDE 2" THK. SPRAY FOAM INSULATION ® EAVES • 5/5" GYPSUM BD. CEILING FINISH WHERE AFFECTED. PROP. P..T. F05T NEW EXTERIOR WALL CONSTRUCTION (AS NEEDED): AS PER (PLAN O2 HOUSE MEMBRANE (SEE SIDING NOTE FOR SPEC.'S) UPON X R • 1/2" GDX PLYWD. 5HEATHING (BLOCKING? ® ALL PLYWD FILL CAVITY OF HDR w/ All EXIST. F.J. SEAMS) UPON • 2"xb" STUDS ® 16" O.G. w/ DEL. TOP PLATE INSULATION (TYP. FOR 1 • PROP. R-51.5 INSULATION SPRAY FOAM INSULATION HDR'S LESS THAN FULL • 5/8" GYPSUM BD. WALL FINISH WIDTH OF EXTERIOR WALLS) - I. INSTALL NEW PAINTED CEDAR SHINGLE SIDING AS PER ELEVATIONS UPON EXIST. -N W 2. TYVEK HOUSE WRAP (VENTED) (OR EQUAL) UPON GREAT �' PROP. EER P05T POST 3 3.EXTERIOR WALL CONSTRUCTION AS NOTED SEPARATELY �t BASE PEER POST SIZE 4.INSTALL ALL AS PER MANU. SPEG.'s _ ROOM j� 2 i EXIST. GONG. SLAB 5. PROVIDE ALL NECESSARY TRIM FOR PROPER 2 `�-� v INSTALLATION 3 TYPICAL FLOOR CONSTRUCTION (AS NEEDED): 4 O I. FIN15H FLOORIN5 TO BE SELECTED BY HOMEOWNER. 2. 5/4" T46 GDX PLYWD. SUBFLOOR GLUED 4 5GREWED EXIST. F.J. 5. F.J. AS NOTED ON PLANS - AT SPANS OVER 5' INSTALL 6i IX' AIN MI BRACE BATT INSULATION CXIST.CRAWL Q 4. MIN. R-30 BATT INSULATION (ONLY BETWEEN FIRST p FLOOR AND FOUNDATION) 5. 2" THK. SPRAY FOAM AT BLDG. PERIMETER RIM JOISTS SPACE EXISTING WALLS NOTE: PROJECT: IN-FILL FRAMING OF EXISTING WALLS SHALL MATCH 51ZE 4 SPACING OF EXISTING WALL STUDS, U.O.N. WHERE THE CAVITIES OF EXISTING EXTERIOR WALL5 ARE �U I L1�I NO SGTI ON I M ICHALECKO GO X ERErL F0R�H DETAIL EXPOSED DURING CONSTRUCTION, FILL CAVITIES w/ REPAIRS SCALE: 3/4" I'-O" FIBERGLASS BATT INSULATION. P�I.00 = SCALE: I/4" = I'-O" PROVIDE STRAPPING 4 NAILING AS PER tP IN "TYPICAL NAIL N5G TTRAPPING 11175 OLD SOUND AVE. REOUIREMENT5 FOR UPLIFT SHEAR, 4 LATERAL RESISTANCE, E55 ANCE" BETOWEEN CAVITIES INSULATIONVIDE MATTITUCK, NY 11952 ON PAGE 0-005 ® EA. STUD. PER ENERGY TABLE (WHEN APPLICABLE) EXIST. SILL PLATES TO REMAIN. DRAWING TITLE: NEW (2) 2"x(b" P.T. SILL PLATES FLOOR SYSTEM AS UPONTERMITE SHIELD IF NEEDED. NOTED ON PLAN D..I EXTERIOR ELEVATIONS a BUILDING SECTION / NE OOKED ANCHOR DESIGN DETAILS BOLTS ® 5q" O.G. w/5" SQUARE WASHER 4 ENDNUT AS NEEDED. a � r PAGE: GRADE , A A2 ® 1.� ®® EXIST. CRAWL SPACE v \\\ DATE: 04/29/26 6 OF 6 e d o a d e J 7 I. CREATE WINDOW OPENING 2. APPLY WATER-RESISTIVE BARRIER; 5. APPLY SILL FLASHING AND 4. INSTALL WIND G OW AND APPLY 5. APPLY HEAD FLASHIN b. FOLD WATER-RESISTIVE BARRIER GUT MODIFIED AND WRAP AROUND SILL WINDOW SEALANT JAMB FLASHING DOWN AND TAPE OVER GUTS AND SIDES OF WINDOW OPENING 4 NATER-F: 51 ST I VE BARRIER A I M 7)ON FLASH+I NO (EXTERIOR r7)CCRS FROM N I N171OrV^I MANUFACJURER) r5 FOUN7AT I ON NALL DETAIL A-201.00 f4-201.00 SCALE: NT5 50ALE: 5/4" = 1'-0"