Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
42912-Z
of Solo/ Town of Southold * * P.O. Box 1179 �0 53095 Main Rd UNTI. Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 47294 Date: 08/17/2026 THIS CERTIFIES that the building ALTERATION Location of Property: 110 Sylvan Dr East Marion, NY 11939 Sec/Block/Lot: 3 7.-3-15.1 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 07/24/2018 Pursuant to which Building Permit No. 42912 and dated: 08/01/2018 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Alterations to an existing single-family dwelling as applied for. The certificate is issued to: Giles Meredith-Jones Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 42912 7/23/2026 PLUMBERS CERTIFICATION: Jose Jimenes 7/31/2026 utho ed Si ature 4*OFSO&. TOWN OF SOUTHOLD BUILDING DEPARTMENT AMENDMENT SOUTHOLD, NY �ourrtr.� BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 42912 Date: 08/01/2018 Permission is hereby granted to: Giles Meredith-Jones 110 Sylvan Dr East Marion, NY 11939 To: Construct alterations to existing single-family dwelling as applied for. Premises Located at: 110 Sylvan Dr, East Marion, NY 11939 SCTM#37.-3-15.1 Pursuant to application dated 07/24/2018 and approved by the Building Inspector. To expire on 03/02/2028. Contractors: Required Inspections: FINAL, Fees: SINGLE FAMILY DWELLING -ADDITION OR ALTERATION $200.00 CO-ALTERATION TO DWELLING $50.00 Amendment Fee $225.00 Renewal Fee $125.00 Total $600.00 Building Inspector �o�g� nc�cv TOWN OF SOUTHOLD yy� BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 42912 Date: 8/1/2018 Permission is hereby granted to: Meredith-Jones, Giles 320 W 38th St Ste 1611 New York, NY 10018 To: make alterations to an existing dwelling as applied for. At premises located at: 110 Sylvan Dr, East Marion SCTM # 473889 Sec/Block/Lot# 37.-3-15.1 Pursuant to application dated 7/24/2018 and approved by the Building Inspector. To expire on 1/31/2020. Fees: SINGLE FAMILY DWELLING -ADDITION OR ALTERATION $200.00 CO - T LLING $50.00 T tal: $250.00 Building Inspector o��OF 50(/Tyol � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G • Q Southold,NY 1 1 97 1-0959 �y�OUNTN,Oc� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Giles Meredith-Jones Address: 110 Sylvan Dr City: East Marion st: NY zip: 11939 Building Permit#: 42912 Section: 37 Block: 3 Lot: 15.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Electrician: Daniel Scalia Electric License No: 71301ME SITE DETAILS Office Use Only Commercial Indoor X Basement X Service X Solar Residential X Outdoor 1st Floor X Pool Battery Storage As-built Renovation 2nd Floor Hot Tub EV Charger New X Addition Attic Spa Generator Survey Mezzanine Garage Dock INVENTORY Service 1 ph X In-wall Heater Recpt 13 Ceiling Fixtures 2 Smoke Detectors 3 Pump Service 3 ph Hot Water GFCI Recpt 1 Wall Fixtures CO Detectors Heater Main Panel 200 A/C Condenser Single Recpt RecessdFixtures 6 Combo Smoke/CO 2 Transformer Sub Panel A/C Blower Range Recpt Gas Ceiling Fan Heat Detectors Salt Gen Transfer Switch Mini Split Dryer Recpt UC Lights 8' Fridge 1 AutoCover ARC 8 Blower Heads Switches Pucks Lights Dishwasher 1 Mini Fridge GFI SepticDisconnect Emrgency Strobe 4'LED Microwave 1 Garbage Disp. ARC/GFI ERV Exit Lights Bath Exhaust Hood 1 Dehumidifier Other Equipment: 200A Panel 40 Circuit/29 Used Notes: Kitchen, Living Rm & Service Inspector Signature: Date: July 23, 2026 SUFFoc,�c Town Hall Hall Annex �l/ Telephone(631)765-1802 �� y�► 54375 Main Road C9 1 P.O.Box 1179 r Southold,NY 11971-0959 - y�0 Sao! (l(u," OVE BUILDING DEPARTMENT 2026 TOWN OF SOUTHOLD Building DePartment CERTIFICATION Town of Southold Date: 2� Building Permit No. `N Z 9-1. Owner: Mejr&jr th JQInevS (Please print) (Please print) I certify that the solder used in the water supply system contain ess than 2/10 of 1%lead. (Plumbers Signature) Sworn to before me this !h1k ?day o 20 ::� PAUL C CAPERNA NOTARY PUBLIC,STATE OF NEW YORK Registration No.01CA6,151160 Notary Public, County Qualified In Suffolk County ty issn Expires August 14.2 1 �v�ty OF SOUI,yo� # # TOWN OF SOUTHOLD BUILDING .DEPT. `ycou 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION [ ] FRAMING /STRAPPING [ FINAL 01A �1���•-. V [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: h �o� DATE INSPECTOR pF SOUTyolo # # TOWN OF SOUTHOLD BUILDING DEPT. coum, ,o 631-765-1802 q,�iiio,-ANSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] F DATION 2ND [ ] INSULATION/CAULKING [ FRAMING /STRAPPING [ ] .FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: Gfl �h l DATE 3 INSPECT0 OF 50bTyOlo Ito IN v * TOWN OF SOUTHOLD BUILDG LE coo 631-765-1802 INSPECTION l [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] .FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION LECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL � REMAR S: Lv I tc Hoj pi oc� Emokes-i- co, IVkn-C�lz 14 AQ+ foej- 0 V4 104, r, 22eq M O a 0 DATE INSPECTOR OF 50UTyOlo 9 Z i l2, - - / I l V�o * TOWN OF SOUTHOLD BUILDINO�DEPT. Comm, 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: v T- A A e. Cl I Co- LA P��C4 .c DATE INSPECTOR o�ao 50bTyOl L4 2 0 l 2 � o # . # TOWN OF SOUTHOLD BUILDING DEPT. Coulm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: i ` tl JQ o' CLNbl 0( i S-2 s DATE INSPECTOR hO�aOF SOUTyO� # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION .-.. [ ] ' FOUNDATION 1 ST/ REBAR- [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I ULATION/CAULKING [ ] FRAMING /STRAPPING P. FINAL ] FIREPLACE & CHIMNEY , [ ] . FIRE SAFETY INSPECTION ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [. ] CODE VIOLATION [ ] PRE C/O [ ' ] RENTAL REMARKS:(to &;;qc..- ca.R470(ck. DATE INSPECTOR hO�apF SOUTyOlo Ll 2 l 12— r / ---- / — - - - - # TOWN OF SOUTHOLD BUILDIN�EPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: i �&A-P-A LIt �l DATE INSPECTOR I 1 • ' • • COMMENTSFOUNDATION \ . 'FOUNDATION ROUGHFRAMING INSULATIONPLUMBING ENERGY • 1 swimil'� ADDITIONAL COMMENTS • NOUN,�i < 1. .�' .. � � 0, ��i.: .. � ;II .r� • OF PEP z m- W2' ✓ , • _ � P P TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631)765-9502 'Survey SoutholdTown.NorthForkxet PERMIT NO. (� Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application Flood Permit Examined gl t 20 Single& Separate ��r / Storm-Water Assessment Form ( Contact: Approved 20 Mail to: Robert Wilson Disapproved a/c PO Box 49 Southold NY 11971 Phone: (631)504-8842 Expiration 20 RD _R� Building ri pecto APPLICATION FOR BUILDING PERMIT JUL 2 4 2018 Date July 24th , 20 18 INSTRUCTIONS BULLDING DEPT- a.VhfVdPp1fditiYd,MMyAe completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale.Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations,for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature o applicant or name,if a corporation) PO Box 49 Southold NY 11971 (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Agent Name of owner of premises Giles Meredith Jones (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: 110 Sylvan Dr. East Marion House Number Street Hamlet County Tax Map No. 1000 Section 37 Block 3 Lot 15.1 f % "i Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Single family residential Same with two new windows added to existing basement. Also new flooring and framed walls. b. Intended use and occupancy Space to remain unheated. 3. Nature of work(check which applicable): New Building Addition Alteration V Repair Removal Demolition Other Work (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units 1 Number of dwelling units on each floor 1 If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front 25' Rear. 25' Depth 35'-6" Height 14' Number of Stories 1 Dimensions of same structure with alterations or additions: Front 25' Rear 25' Depth 35'-6" Height 14' Number of Stories 1 8. Dimensions of entire new construction: Front 25' Rear 25' Depth 35'-6" Height 14' Number of Stories 1 9. Size of lot: Front 125.00' Rear 125.00 Depth 100.00, 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated R-40 Medium Density Residential 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO V 13. Will lot be re-graded? YES NO V Will excess fill be removed from premises? YES NO_ /� 110 Sylvan Dr. 14. Names of Owner of premises Giles Meredith,tones Address East Marion NY Phone No. (631)504-8842 Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES,D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey,to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO_V * IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF ) Robert Wilson being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, CONNIB D.BUNCH Notary Public,State of New York (S)He is the Agent No.01 BU6185050 (Contractor, Agent, Corporate Officer, etc.) Qua n swolk County Commission Expires April 14,2.b au of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief, and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this Q day of 2012 Notary Public gna Applicant j suEFoi , TOWN OF SOUTHOLD—BUILDING DEPARTMENT y p Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone 631 765-1802 Fax 631 765-9502 h s//www.southoldtomM. ov *,Y�apl'Y p � ) � ) ttP g Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. Building Inspector: r; Applications and forms must be filled out in their entirety. Incomplete applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date: OWNER(S)dF PROPERTY: Name: (�7—/Zd Mee /�--i——(-)Na SCTM#1000- Project Address: / 0 SyL114r,y Phone#: 9� 7 Email: Mailing Address: �� -0 `011,,) D CONTACT PERSON: Name: Q 9 &W�7H- _ Mailing Address: I1<9 S i BOA Phone#: 7 071 Email: c M DESIGN PROFESSIONAL INFORMATION: Name: S ©1/lr Mailing Address: Ph6he# �' �... s ,"(j;s,t Email• ,I��J e,M Ct,M - .15�/I CONTRACT6""-; Name: �� Mailing Address: 0-7/ ,/��(i a//j /11CZ/-k, 3 //77 ry. Phone#: '/ Email: DESCRIPTION OF PROPOSED CONSTRUCTION El New Structure ❑Addition TfAlteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other Will the lot be re-graded? ❑Yes No f Will excess fill be removed from premises? es 1 PROPERTY INFORMATION Existing use of property: rW plot (41& Intended use of property: ���1:oN� t4 f� Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ZNo IF YES, PROVIDE A COPY. J. Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal;or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210AS of the New York State Penal Law. Application Submitted By(print name): �� — ✓ a/ ❑Authorized Agent MOwner Signature of Applicant: / Date: STATE OF NEW YORK) SS: COUNTY OF SU FF01 '. ) being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the none, (Contractor,Xgent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief,and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this t)^ day of 20_6& --�,40aw otary Public TFIXEY L. D EFI •NOTARY PUBLIC,STATE OF NSW YORK NO.01 DW6306900 PROPERTY OWNER AUTHORIZATION OQ6 LIFfED IN SUFFOLK COUNTY (Where the applicant is not the owner) COM WION EXPII';EVUNE 30,Z„ 96 nWh I?�l-� ,)ON residing at ��� ► � do hereby authorize A7-0/lj a21"/"I►�/ W2r� to apply on my beha f tSth of Southold Building Department for approval as described herein. - 2, Owner's ignature Date 00 Print Owner's Name 2 Mejia. Evelin From: Giles Meredith-Jones <gilesmj@gmail.com> Sent: Friday, March 20, 2026 7:00 PM To: Mejia, Evelin;Walter Tzun Subject: Fwd: 110 Sylvan Dr, East Marion - Giles Meredith-Jones ---------- Forwarded message --------- From: Giles Meredith-Jones < ilg esrd gmail.com> Date: Fri, Mar 20, 2026 at 6:58 PM Subject: 110 Sylvan Dr, East Marion- Giles Meredith-Jones To: <evelimmgsoutholdny.gov> CC: <waltertzun@hotmail.com> Hi Evelin Good talking to you today. As mentioned, this is confirming that_mynewMCarpenter is Walter Tzun of rChenal&Tzun ConstructionlLC. Walter will forward me the following and I will pass to you: - Certificate of Insurance -Workers Comp - Licence Thanks for arranging for John to inspect the Framing on Thursday 26th March. Walter, please call DOB at 8.30am that day (on (631) 765-1802 to find out what time John can stop by. Thanks and have a great weekend Giles Giles Meredith-Jones 110 Sylvan Dr ATTENTION: This email came from an external source. Do not open attachments or click on links from unknown senders or unexpected emails. 1 v a � � F0t O BUILDING DEPARTMENT-Electrical Inspector JOWN OF SOUTHOLD Town Hall Anhex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 y�j01 �a0� Telephone (631) 765-1802 APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All information Required) Date: W'a n Company Name: Daniel Scalia Electric Inc. Electrician's Name: Dan Scalia License No.: ME-71301 Elec. email:Danielscalia11 @gmail.com Elec. Phone No: 631-793-9999 01 request an email copy of Certificate of Compliance Elec. Address.: 875 Crown Land Lane, Cutchogue NY 11935 JOB SITE INFORMATION (All Information Required) Name: rea One^j Address: 110 $ 1Va r. E&S t mar.-On Cross Street:&0CC h- Lh G + S-r Phone No.: BIdg.Permit#: gQ- %g1a email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): li vll` Jwin/K;+rhcn Reno Square Footage: ) Circle All That Apply: Is job ready for inspection?: X YES❑NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES®NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service[]Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead #Underground Laterals 1 n2 H Frame 171 Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION L1-,3 �d `� 150 Re,�t� 1119`73 VZ-) Vf BUILDING DEPARTMENT- Electrical Inspector 7 GG TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 o Southold, New York 11971-0959 Telephone (631) 765-1802 4r APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All information Required) Date: L41;V;I6 Company Name: Daniel Scalia Electric Inc. Electrician's Name: Dan Scalia License No.: ME-71301 Elec. email:Danielscalial I @gmail.com Elec. Phone No: 631-793-9999 El I request an email copy of Certificate of Compliance Elec. Address.: 875 Crown Land Lane, Cutchogue NY 11935 JOB SITE INFORMATION (All Information Required) Name:I'AereA - :5bn(25 Address: 110 $y I\(a 1) rg-, EC,5.t Ma Non Cross Street:�VOC}h, Ln 10C M4- S-r Phone No.: Bldg.Perrnit#: 13P- 42kql-A email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Jwrn/K;+Chcn RP-1110 Square Footage: Circle All That Apply: Is job ready for inspection?: YES 0 NO R Rough In E] Final Do you need a Temp Certificate?: F-1YES NO Issued On Temp Information: (All information required) Service SizeF-11 Ph❑3 Ph Size: A #Meters Old Meter# ElNew ServiGeF-1 Fire ReconnectE]Flood Reconnect[:]Service Reconnect[—]Underground EjOverhead #Underground Laterals E]I F-]2 F-1 H Frame D Pole Work done on Service? F-]Y FIN Additional Information: PAYMENT DUE WITH APPLICATION Ll PERMIT# Address: Switches l Outlets G F I's Surface Sconces HH's UC Lts , Fridge HW POOL Fans Mini Fr. W/D PanelPump Exhaust Oven c4l� Sump Heater Trnsfmr Smokes I� DW Generator Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower AC AH Hood Blower Service Amps Have Used Zqj Sub Amps Have Used Comments Scott A. Russell ,s....= S]F01KMWA T1E1K SUPERVISOR JMANAGEMENT SOUTHOLD TOWN HALL-P.O.Box 1179 0 53095 Main Road-SOUTHOLD,NEW YORK 11971 _ '+ Town of Southold CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT ) 11 DOES THIS PROJECT INVOLVE ANY OF THE FOLLOWING: Yes No (CHECK ALL THAT APPLY) ❑❑ A. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. ❑0 B. Excavation or filling involving more than 200 cubic yards of material within any parcel or any contiguous area. 1 ❑0 C. Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. �� ❑0 D. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. ❑❑ E. Site preparation within the one-hundred-year floodplain as depicted on FIRM Map of any watercourse. ❑® F. Installation of new or resurfaced impervious surfaces of 1,000 square I � feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes I� T —in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with your Building Permit Application. APPLICANT: (Property Owner,Design Professional.Agent,Contractor,Other) S.C.T.M. 1000 Date: District i NAME: Robert V 37 3 15.1 7/24/2018 Section Block -- Lot FOR BUILDING DEPARTMENT USE ONLY Contact Information: (631)504-8842 1Tckphonc.tiumM.i — — — — — Reviewed By: I — — — — — — — — — — — f{i � - - - - - - - - Date +' Property Address/ Location of Construction Work: — — _ — — — _ - � 110 Sylvan Dr. I Approved for processing Building Permit. Stormwater Management Control Plan Not.Required. East Marion NY ElStormwater Management Control Plan is Required. (Forward to Engineering Department for RevietvJ FORM 11 SMCP-TOS MAY 2014 Town Hall Annex f � Telephone(631-1802 54375 Main Road Fax.(631) 734-9502 P_ Cl. Box 1.179 o hz Southold, NY 11.971-0959 .BUILDING DEPARTM'EMT NOTICE OF UTILIZATION OF TRUSS TYPE CO.NSTRUGTION, PRE-ENGINEERED WOOD CONSTRUCTION ANDIOR TIMBER COMS:TRUCTION. Date: July 24th Owner, Giles Meredith Jones Location of Property: 110 Sylvan Dr. East Marion NY. Please take notice that the (check applicable line); Newresidential structure Addition to existing residential structure Rehabilitation to an existing fesidential.structure to be constructed.-or perfon-ned at the s. bjpct property referQpce above:will utilize { (check applicable line): *_ r Truss type.construction (TT) Pre-engineered wood construction;Pw) Timber construction (TC) to the following iocation(s).(check applicable lime): Floor.framing..indudi g girders and beams (F) ' _�_. :. — Roof framing(R) Moor and roof -earning (FR) Signature- Name•(person submitting this form): RobertVAIson t Capacity(check applicable line):, � Owner - i Owner representative I.. TrussResReg15.docx Effeclive 1!1l2015 f FGliiu.4c+.,:� .�7a2f��`_iYa�11:dL • .. ...' -.....- ., .., ��,4�'"'(.�y�y"tim,P„rn' 'n', �y`2�it n�tr� .r',.wwiws[r.I•K -. - 6" DIAMETER . it ZEFLECTIVE RED �-- ROMAN[ALPHANUMERIC •"PkKU i ON12 CON ST.Rti%T'1c7Jd (PMS) ff18? ;1(pE BASED ON SECTION 682 OF THE BU.ILIMKG,CODE OF.NEW YOW STATE 2MacREFLEGTtVE WHITE F � • x C.OiV(p-,ciaglo TB-rti'A`:Al@E'OF TRUSS CONSTRUCTION "F" FLOOR FRAMING;MCL.UlitNG hGtRDER1�iAF!!3•�EAIYIS� , "R` ROOF PRlEtidBtYG "FR FLOQR AND ROOF VRAtJII46, T SS 10B\MFICAMON SIGN RU A611 C. srr�l�ra�I IGN DAM - _,, NEW YORK STATE DEPART ENT bF S`!`AT-E DIVIS10N OF CODE E N FOR EMENT AND ADM I N I STRATI.ON 6,1.6F7X':IIT'�ylsa:: , I -�7 t4. AT cv nr. s'ao• - �oO.Q Tore• oi= �Soij r'Hty-c,N.Y w ( 6-+R.?-� enc�. i � •� 4 x inCtt�f►i�a i lifot�;:Lot •su!'rrb�era �-ya.�«t refer ha fkNSa'7l.iiq �' ,, � ; �C<'t°'�CN ����=F.�� •'"tom �St►�p���"C, - '�. ORIUD ACTUATIO0 OR ApwiT Oty _ ` ► fr?rk� '.i'G i• C� !✓l^p !'goo THis SUF.YEY Is A VIOLATION OF t 'SECTION 72D9 OF THC MEW. Ym4 sTA ri ,. Q Zd{ a EDUCATION LAW. i - COPIES OF TH:S S,7VEY MAP V. T SV RLLfj THE LA.,G N',: ':A:02 EM3OSSID VIAL S'a_L N--f 6:C.:,w .IMEO �! � TO M A VA.:G Z.! . �D �OF1. s ego GU AXTUS�01,^A',` �';' ^. S'-s R14 .•• y� ass J`��'W. � —' IQv�.�j �� ONLY TO THE✓:ISO S0: •S' SCR ,V IS PREFA:EG, A\D'?, ••; ;�,3 t +:. H8'' 1� C� .�• ,�•ti'' lfC 1 /9-?47TTtf COMPAR" lJ 3 LEWING I,\5'.+TUi:C„L3:.1 ,.r.O., � C )� To THE ASS;G aS OP T,-L+:*,:'tiG 1 MW • _.. .. __ .. .- ._._ {'j"� �. _��'-..t`jrf_. ..�-'^'�PTO ADDITIONAL tNSYtMCAS OR SU 3EC_ 1.r• �. Y c:.e.+w�.. � .o}ryll DINNERS• � - _.�.__•-__,..._J . ....-- -_.. ..___-- __ . _.._,...�. . .........,.5� aLrceits�ed 1;,�'I"Yi �:r�.+��ror� M +L©G(/5T C7: rc rfaor -� mew :o-Y 431VIIII Scotchshield"I - • • Data Sheet S2400 Revision • 2024 ql o� IMPORTANT:This Technical Data Sheet provides an overview of the specified product's performance. Prior to product selection,always refer to the current 3M Technical Specifications for more detailed product information and specifications.All technical data and information in this data sheet should be considered representative or typical only and should not be used for specification purposes. Product Description //05 11d4-, 2�Y • Polyurethane construction,flexible film designed for enhanced tear resistance and glass fragment retention • Polyurethane construction provides greater tear strength and elongation than polyethylene terephthalate(PET) resin film of similar thickness,allowing the film to absorb impact • Optically clear • For application only to interior glass surfaces of windows and doors • Engineered to help hold broken glass in place • Helps prevent flying glass shards from harming occupants and damaging property • Blocks up to 99%of the sun's harmful UV rays,the largest cause of fading Applications �_! J L ` • Helps prevent flying glass shards in the following applications: s - Spontaneous Glass Breakage MAR 2026 n- - Break and Entry Incidents - Seismic Events - Intentional and Accidental Explosions - Impact protection from wind-borne debris • Helps delay intruders in break and entry incidents • Helps protect against ultraviolet(UV)fading • Helps meet many industry performance standards for glass fragment retention Product must be installed with the 3MT1 Impact Protection Attachment(IPA)Sealant for all windstorm,break &entry,and explosion mitigation applications and for all spontaneous glass breakage applications on single pane tempered glass.The product is not bulletproof and is not designed to stop intruders. Product must be installed strictly in accordance with 3M Technical Specifications and 3M instruction guidelines. Important Handling and Installation Instructions:This thick but flexible film has both an adhesive liner and a protective top sheet. Precut sheets should be handled carefully and shipped flat to avoid pop-off of the liner, which may result in a visible defect after installation.The protective top sheet can be left on as an aid to installation but must be removed prior to application of 3MTM Impact Protection Attachment(IPA)Sealant. Product Properties Film Properties Graves Tear Area Under Film Thickness(with 25 mils(630p) Curve 24.6 Ibf"in adhesive) nominal (ASTM D1004, 12 in/min, Film Construction TPU initial grip separation 1.6 in) Tensile Properties(ASTM D882) Flammability(ASTM E84) Class A Tensile Strength at 300% Solar Properties— film Elongation 1600 psi applied to X"clear glass Tensile Strength at Break 3200 psi Visible Light Transmitted 89% Break Strength 77 Ibs/in UV Light Rejected 99% Elongation at Break 560% Other Physical Properties 180 Degree Peel Strength on 3.2 Ibs/in Glass(ASTM D3330) 1 /3 • •" Security Window Film Technical Data Sheet S2400 Revision • Performance Testing Method Glass Substrate Rating Safety Glazing ANSI Z97.1 1/4"&1/8"annealed Class A(Unlimited),400 ft-Ibs and Class B(Unlimited),150 ft-Ibs Method Glass Substrate(24"x 24") UL 972 results Impact Resistance UL 972 Sect.6.2 1/4"annealed Pass Ball Impact Test 1/4"tempered Pass UL 972 Sect.6.4 Thermal Conditioning Test and Impact Test for 1/4"annealed Pass 1/4"tempered Pass Indoor Use UL 972 Sect.6.5 1/4"annealed Pass High Energy Impact Test 1/4"tempered Pass Film GSA Performance Method Glass Substrate Attachment* Blast Load Condition and/or ASTM Hazard Rating Blast Mitigation GSA TS01-2003 6 psi,42 psi GSA Rating of"2" ASTM F1642 1/4"annealed IPA msec ASTM F1642"Minimal Hazard" GSA TS01-2003 6 psi,42 psi GSA Rating of"2" ASTM F1642 1/4"tempered IPA msec ASTM F1642"Minimal Hazard" *IPA=3MT""Impact Protection Attachment(IPA)Sealant,all 4 sides Health &Safety WARNING.To help reduce the risk of personal injury and/or property damage associated with glass breakage, when working on or near glass surfaces, always use appropriate personal protective equipment and follow the Technical Bulletin "3MT1Window Film Glass Checklist"to identify the risk of glass breakage associated with the application of window film to glass surfaces. CAUTION. When using any equipment, tools, or cleaning solutions in connection with the processing and application of this Product,always follow the manufacturer's container labels and/or instructions for safe operation. Important Product Notices IMPORTANT PRODUCT AND APPLICATION LIMITATIONS: Many factors can contribute to potential hazards and damages arising from wind, impact,seismic,explosion,or break and entry incidents,including the window film selected, type and thickness of glass, building construction, exterior pressure, proximity of impact occurrence, quality of window or door frames, intruder size and strength, and type of tools used to gain entry. Certain 3M TM Window Films require the use of 3MTm Impact Protection Attachment (IPA) Sealant on glass window and door frames for windstorm, break & entry, and explosion mitigation applications and for spontaneous glass breakage applications on single pane tempered glass.The sealant may also be recommended for certain other spontaneous glass breakage, safety glazing, and seismic applications. Always refer to the 3M Technical Data Sheets and 3M Technical Specifications to determine whetherthese combinations are required. CAUTION:While 3MTM Window Films,when applied in accordance with 3M instructions, may help reduce the impact of flying glass shards under certain conditions and potentially delay intruders,these films do not prevent property damage,personal injury,or death.CAUTION:Window films are not bulletproof and not designed to stop intruders.Always consult with security professionals and a 3M Authorized Window Film Dealer prior to selecting any window films to determine suitability for the intended application. 2/3 • •"I Security Window Film Technical Data Sheet 400 RevisionApril IMPORTANT STATE OF FLORIDA NOTICE: This product is not approved in the State of Florida for use as hurricane,windstorm,or impact protection from wind-borne debris from a hurricane or windstorm. In compliance with Florida Statute 553.842,this product may not be advertised,sold,offered, provided,distributed,or marketed in the State of Florida as hurricane, windstorm, or impact protection from wind-borne debris from a hurricane or windstorm. Warranty Information Technical Information: Technical information, guidance, and other statements provided by 3M are based upon records,tests, or experience that 3M believes to be reliable, but the accuracy, completeness, and representative nature of such information is not guaranteed.Such information is intended for people with knowledge and technical skills sufficient to assess and apply their own informed judgment to the information. No license to any intellectual property rights is granted or implied with respect to this technical information. Product Selection and Use: Many factors beyond 3M's control and uniquely within user's knowledge and control can affect the use and performance of a 3M product in a particular application.Customer is solely responsible for evaluating the product and determining whether it is appropriate and suitable for customer's application, including conducting a workplace hazard assessment, reviewing all applicable regulations and standards,and reviewing the product label and use instructions. Failure to properly evaluate,select, and use a 3M product in accordance with instructions or to meet all applicable safety regulations may result in injury,sickness,death,and/or harm to property. Warranty,Limited Remedy,and Disclaimer: Unless a different warranty is specifically stated on the applicable 3M product packaging or product literature(in which case such warranty governs),3M warrants that each 3M product meets the applicable 3M product specification at the time 3M ships the product. Please refer to the Warranty Bulletin for 3MTm Window Films(Flat Glass Applications)and 3MT1 Impact Protection Attachment(IPA)Sealant for complete details on warranty coverage, which can be obtained by contacting your 3M Authorized Window Film Dealer or your local 3M sales representative.3M MAKES NO OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO,ANY WARRANTY OR CONDITION OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE,OR ARISING OUT OF A COURSE OF DEALING,CUSTOM,OR USAGE OF TRADE. If a 3M product does not conform to this warranty,the sole and exclusive remedy is, at 3M's option, replacement of the 3M product or refund of the purchase price. Limitation of Liability: Except for the limited remedy stated above,and except to the extent prohibited by law,3M will not be liable for any loss or damage arising from or related to the 3M product,whether direct,indirect,special, incidental,or consequential(including,but not limited to,lost profits or business opportunity),regardless of the legal or equitable theory asserted, including, but not limited to,warranty,contract, negligence,or strict liability. Commercial Branding and Transportation 3M Center,Building 223-3N-30 St. Paul,MN 55144 3M.com/windowfilm ©3M 2024.All rights reserved. 3M and Scotchshield are trademarks of 3M.Used under license in Canada. All other trademarks are the property of their respective owners. 3/3 f 1•IYf � i R.EScheckoWeb Compliance Certificate Project Information Project Title: Jones Residence Energy Code: 2024 IECC Location: New York,New York Construction Type: Single Family Project Type: Addition Project Sub Type: None Glazing Area: 32% Climate Zone: 4a(5362 HDD) Permit Date: 2025-12-30 Project No: 1807854 All Electric: false Is Renewable: false Has Battery: false Has Charger: false Has Heat Pump false Construction Site: Owner/Agent: Designer/Contractor: 110 Sylvan Lane John Condon East Marion,NY 11939 1755 Sigsbee Road Condon Engineering,PC Mattituck,NY 11952 16312981986 condon77173@optonllne.net Project Notes: Report Title:Jones Residence Report Date: 1/5/26, 1:28 PM 1 of 12 Envelope Assemblies Prop. Req. Assembly Gross Area or Cavity Cont. U- U- Prop. Req. Perimeter R Value R Value Factor/ Factor/ UA UA F-Factor F-Factor Ceiling 1:Flat Ceiling or 243 38:0 2.5 0.028 0.026 7 6 Scissor Truss Ceiling:Cathedral 544 30.0 2.5 0.031 0.026 17 14 Ceiling Wall:Wood Frame,16" 395 21.0 2.5 0.049 0.045 13 12 O.C. Window:Wood Frame 127 0.280 0.300 35 38: SHGC:0.32 Wall 1:Wood Frame,16" 90 21.0 2.5 0.049 0.045 4 4 O.C. Wall 2:Wood Frame,16" 368 21.0 2.5 0.049 0.045 10 9 O.C. Window'1:Wood Frame 149 0.280 0.300 42 45 SHGC:0.32 Door:Solid Door(under 20 0.260 0.300 6 6 50%glazing) Conipliance: Passes using Tc trade-off 1 1' getter Than Code Max UA:134 Your UA- 134 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Compliance Statement The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2024 IECC requirements in REScheck-Web and to comply with the mandatory requirem s isted in the REScheck Inspection Checklist. John j Condon, PE C.10 Name -Title I re Date I J Report Title:Jones Residence Report Date: 1/5/26, 1:28 PM 2 of.12 Inspection Checklist 1 Energy Code:2024 IECC Requirements:0%were addressed directly in the RESCheCk software Text in the"Comments/Assumptions"column is provided by the user in the REScheck Requirements screen.For each requirement,the user certifies that a code requirement will be met and how that is documented,or that an exception is being claimed.Where compliance is itemized in a separate table,a reference to that table is provided. Pre-Inspection/Plan Review Sec�j Plans Field f # 9 Verified Verified ! &Req.iD Pre-inspection/Plan Review j .Value Value { Complies? Comments/Assumptions 105.1, Construction drawings and Complies 105.2 documentation demonstrate [PRl)1 energy code compliance for the ❑Does Not building envelope.Thermal Comply envelope and energy Not compliance path represented on servable construction documents. RNot plicable 105.1, Construction drawings and Complies 105.2, documentation demonstrate 403.8 energy code compliance for []Does Not [PR3)1 lighting and mechanical Comply systems.Systems serving []Not multiple dwelling units must Uservable demonstrate compliance with the IECC Commercial Provisions. Not pplicable 302.1, Heating and cooling equipment Heating; Heating: Complies 403.7 is sized per ACCA Manual S Btu/hr Btu/hr [PR2]1 based on loads calculated per Does Not ACCA Manual I or other methods omply approved by the code official. Cooling: Cooling: Not Btu Btu servable PpNot plicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Report Title:Jones Residence Report Date: 1/5/26, 1:28 PM 3 of 12 Foundation Inspection section &Req.ID Foundation Inspection $ Complies? Comments/Assumptions ' 403.8 Systems serving multiple dwelling units O Complies [FI91]2 comply with Sections C403 and C404 of the commercial code. Does Not Imply ((��]Not �Gservable [�Not pplicable 403.9.1 Heating systems installed for outdoor C)Complies [F192]2 heating are radiant systems controlled by occupancy sensing or timer switch. Does Not omply Not servable Not pplicable 403.9.2, Snow and ice-melting system controls 0 Complies 403.9.3. installed to shut off system when Does Not 403.9.4 pavement temperature>50F and no [FI92]2 precipitation or automatic controls to comply shut off the system when outdoor Not temperature>40F. servable PNot plicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Ter 2) 3 Low Impact(Tier 3) Report Title:Jones Residence Report Date: 1/5/26, 1:28 PM 4 of 12 Framing / Rough-in Inspection Section 3 Plans.' ; Field i Framing'/Rough-In f Verified "'£ Verified I s &RegaD I Inspection i . 'Value # Value '. Complies? Comments/Assumptions 1 303.1.3 U-factors of fenestration " �),.° O Complies [FR411 products are determined in Does Not accordance with the NFRC test j procedure or taken from the Comply default table. Q Not Observable Not pplicable 402.5.1.1 Air barrier and thermal barrier O Complies [FR23]1 installed per manufacturer's instructions. Does Not Comply (�[Not `Observable Not Applicable 402.5.3 Fenestration that is not site built - Complies [FR20]1 is listed and labeled as meeting AAMA/WDMA/CSA Does Not 101/I.S.2/A440 or has infiltration omply rates per NFRC 400 that do not Not exceed code limits. cservable PpNot plicable j 402.5.4 fixtures sealed ad lighting Complies '[FR16] housingfinterior finish and + nn Does Not labeled to indicate s2.0 cfm �Omply leakage at 75 Pa. f1 Not servable n Not pplicable 403.4 HVAC %in conveying fluids Complies [FR1712 above p15 F or chilled fluids R� R� s below 55 9F are insulated to>R- Does Not 3, omply i ❑Not Observable Q Not Applicable 403°6 Automatic or gravity dampers Complies [FR19]2 are installed on all outdoor air Does Not intakes and exhausts for mechanical ventilation systems. omply Not servable Not pplicable 403.6.1 Ventilation systems in climate O Complies [FR30]2 zones 6,7&8 shall utilize heat or energy recovery with Does Not balanced ventilation and a omply sensible recovery efficiency O Not (SRE)>=65%at 32 F. Observable PNot plicable 403.3.3 Su pIy and return ducts in attics Complies [FR12]1 in slated>=R-8 where duct is Does Not >=3 inches in diameter and >=R-6 where<3 Inches. omply Not I servable Q Not Applicable Report Title:Jones Residence Report Date: 1/5/26, 1:28 PM 5 of 12 Section f Plans Field ; # ( Framing/Rough In 1 Verified Verified I s &Req.ID .; Inspection Value. value # complies ,CommentOkssumptions { 403.3.6 Ducts,air handlers and filter O Complies [FR1311 boxes are sealed with joints/seams compliant with Does Not International Mechanical Code omply or International Residential RNot Code,as applicable. servable Not pplicable 403.4.1 I Protection of insulation on HVAC : 'i Complies [FR24]1 piping. Does Not omply (�Not ( i36servabie i Not Applicable 403.5.2 Hot water pipes are Insulated to R= RJR Complies [FRi8]2 i 1 inch of insulation. _J I� Q Does Not Comply Not servabie [1 Not pplicable 402.5.5 Air-sealed electrical and 0 Complies [FR29]2 communication boxes installed in the thermal boundary of the Q Does Not envelope sealed to limit air Comply leakage between conditioned Not (� and unconditioned spaces. servable PNot plicable 403.3.1 Duct systems are design and Complies [FR1211 sized in accordance with ACCA y Does Not Manual D.Duct systems serving multiple dwelling units is sized "Comply in accordance with ASHRAE Not Handbook of Fundamentals, Observable ACCA Manual D or an equivalent Not methodology, pplicable 402.1, Door U-factor. U U Complies See the Envelope 402.4 4 P[]Does Not Assemblies table for [FR11 Comply values ((��Not Observable i Not I ki pplicable ! t 402.1, Glazing U-factor(area-weighted U(�] U O Complies See the Envelope 402.4.1, I average). �J 1 Assemblies table for 402.4.3, 1 J+�Does Not values 402.6 °mply [FR211 ��Not servable wNot (�] plicable Additional Comments/Assumptions: i I i 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Report Title:Jones Residence Report Date: 1/5/26, 1:28 PM 6 of 12 Insulation Inspection f Section # Plans: Field # . . f Verified ,. Verified I f &Req.ID ) Insulation Inspection Value' S Value Complies? Comments/Assumptions I 1303.1 All installed insulation is labeled Complies [IN13]2 or the installed R-values Does Not provided. ((�� �ompiy S n Not servable Not Applicable 303.2 Wall insulation is installed per Complies [IN4]1 manufacturer's instructions. []Does Not Compiy RNot ((�� servable Not Applicable 402.1, Wall insulation R-value.If this is R� R�-1 Complies See the Envelope 402.2.6, a mass wall with at least 1/2 of �� Assemblies table for 402.2.7 the wall insulation on the wall Wood Wood ❑Does Not values [IN3]1 exteriormply requirement applies the r(FRIO.insulation El Mass Mass COoNot El Steel Steel Observable Not pplicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) 1 Report Title:Jones Residence Report Date: 1/5/26, 1:28 PM 7 of 12 Final Inspection Provisions Section Plans # Verified Verified &;Req.ID. Final Inspection Provisions Value Value Complies? Comments/Assumptions 303.1.1.1. Ceiling insulation installed per 0Complies 303.2 manufacturer's instructions. [FI211 Blown insulation marked every Does Not 300 ft2. Imply QNot servable [1 Not ppllcable 303.3 Manufacturer manuals for 0 Complies [F[18]3 mechanical and water heating Does Not systems have been provided. (�] Comply []Not observable (�Not pplicable 403.2 Hot water boilers have. 0 Complies [FI26]2 automatic outdoor setback Does Not control to lower boiler water Q temperature based on outdoor Comply temperature,indoor Not [ ] temperature or water servable temperature sensing. (1 Not pplicable 403.3.6.1 Air handler leakage designated 0 Complies [FI24]1 by manufacturer at<=2/0 of design air Flow. �']Does Not Pmply � Not Observable n Not Applicable 403.3.7 Ducts are pressure tested in 0 Complies [FI27]1 accordance with ANEI/RESNET/ICC 380 or cfm/100 ft2 Cfm/100 ft2 Does Not ASTME1554 to determine air Imply leakage with either:Rough-in (—]Not test:Total leakage measured Pjservable with a pressure differential of 0.1 inch w.g.across the system Not Including the manufacturer's pplicable air handler enclosure if Installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g.across the entire system including the manufacturer's air handier enclosure. 403.3.8 Duct tightness test result of 0 Complies [F1411 <=4 cfm/100 ft2 across the system or<=3 cfm/100 ft2 Cfm/100 ft2 cfm/100 ft2 Does Not without air handler @ 25 Pa. Imply Duct tightness<=8 cfm/100 Q Not ft2 for ducts within thermal Observable envelope.For rough-in tests, verification may need to occur (�Not during Framing Inspection. pplicable 403.5.1 Circulating service hot water 0 Complies [F111]2 systems have automatic or [ ] accessible manual controls. Does Not q Comply UNot [� servable Not l�ppl cable 403.5.1.1.1 Demand recirculation water 0 Complies [F132]2 systems have automatic controls to start pump when Does Not hot water is requested. Imply Not servable PNot plicable Report Title:Jones Residence Report Date: 1/5/26, 1:28 PM 8 of 12 Section I Plans Field, i # Verified Verified } &-Req.ID_ Final Inspection Provisions Value Value Complies?. Comments/Assumptions 403.5.1.1 Heated water circulation Complies [F128]2 systems have a circulation pump.The system return pipe yn�Does Not is a dedicated return pipe or a omply cold water supply pipe.Gravity Not and thermos-syphon circulation servable systems are not present. Controls for circulating hot Not water system pumps start the pplicable pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace syystems Complies [F129]2 comply with IEEE 515.1 or UL Does Not 515.Controls automatically [�] adjust the energy input to the Comply heat tracing to maintain the [�Not desired water temperature in O servable the piping. '" ' F1 Not Applicable 403.5.3 Drain water heat recovery Complies [FI31]2 units tested in accordance with ; Does Not CSA B55.1.Potable water-side pressure loss of drain water omply heat recovery units<3 psi for ❑Not individual units connected to Observable one or two showers.Potable water-side pressure loss of (�Not drain water heat recovery units pplicable <2 psi for individual units connected to three or more showers. 401.3 Compliance certificate posted 0 Complies [F17]2 with building specifications, compliance path,R408 energy Does Not credits,results and solar ready omply zone if provided. Not Observable PNot licable 403.6.2 403.6.2:All mechanical Complies [FI25]2 ventilation system fans meet efficacy and air flow limits per Q Does Not Table R403.6.2. Comply Q Not Observable PNot plicable 403.6.3 Mechanical ventilation systems 0 Complies [FI33]2 tested and verified to meet the Does Not minimum flow rates required Q by Section R403.6. comply UNot iv (��jseable 1Not pl cable 403.6.5 Intermittent exhaust for Complies [F134]2 bathrooms/toilet rooms has Does Not automatic control,occupant sensor control,humidity omply control or contaminant control. Not servable Not )rpplicable 402.1, Ceiling insulation R-value. R R Complies See the Envelope 402.2.1. Doe Assemblies table for 402.2.2, Wood Wood 0 Does Not values ply [Fill' []Steel 0 Steel ❑Not Observable Not pplicable e. Report Title:Jones Residence Report Date: 1/5/26, 1:28 PM 9 of 12 Section ;° Plans } Field # Verified_ Verified &Req ID Final Inspection,Provisions. ' " Value t Value Complies? .Comments/A'ssumptions 403.13, Gas fireplaces equipped withCJ Complies 403.13.1 on-demand pilot,intermittent [FI35]3 ignition or interrupted ignition. Does Not Fireplace efficiency>50%in omply accordance with CSA P.4.1 Not [� Rservable i Not pplicable 404.1 100%of permanent fixtures Complies [F1611 have high efficacy lamps. Does Not Comply QNot servable Not pplicable 404.1.2 Exterior 11 hting power is below Q Complies [FI35]3 the allowabble wattage in Table Does Not R404.1. [] Comply 9Not servable Not pplicable 404.1.5 Fuel gas lighting systems have Complies [FI23]3 no continuous pilot light. PDoes Not mply RNot ((��] servable Not pplicable 404.2.1, Permanent interior lighting Complies 404.2.2 shall be controlled with either a Does Not [F136]3 manual dimmer,occupancy sensor or auto shut off control s omply based on occupancy built with QNot manual override. dTiservable PNot plicable 404.3 Exterior lighting>=30 watts0 Complies [F[31]3 shall have the following Does Not controls:manual on/off switch (] with automatic shut-off, Comply automatic shut-off in daylight Q Not hours,and controls that Not override automatic shutoff that returns to automatic control ((��]]Not within 24 hours. ]pplicable 404.4 Where renewable energy Complies [F[36]3' generation equipment is installed,renewable energy P Does Not credits(RECs)or energy omply attributable certificates(EACs) (—]Not associated with the renewable servable energy used for compliance are " provided to the code official Not pplicable 402.2.4 Vented attics with air0 Complies [F12212 Permeable insulation include Does Not baffle adjacent to soffit and Q eave vents that extends over Comply insulation. ((��j Not ZSCiservable ". Not Pplicable 402.2.5 Attic access hatch and door R(�1 R I� h Complies [F1311 insulation>_R-value of the l� l—J I II adjacent assembly. Does Not omply ! []Not Observable }P Not pplicable Report Title:Jones Residence Report Date: 1/5/26, 1:28 PM 10 of 12 Section . Plans i Field j 1 Verified tt Verified &Req:ID j Final Inspection Provisions Value 1 Value Complies? Comments/Assumptions 1402.5.1.3 Blower door test @ 50 Pa. ACH�50-- I ACH�50 Complies <=4.0 ACH50 in Climate Zones 11111711 1-2,<=3.0 ACHSO in Climate Does Not Zones 3-5 and<=2.5 ACH50 omply in Climate Zones 6-8. Not f � [Observable Not ( i :Applicable i 7 i 402.5.2 Wood-buminy fireplaces have O Complies [FIB]2 tight fitting flue dampers and Does Not outdoor air for combustion, om I Py qNot servable Q Not applicable 402.3 Radiant barriers are installed in R( 1 R= Complies Seethe Envelope [FI43]2 accordance with ASTM C1743 L� Does Not Assemblies table far Wood Wood values omply i13 Steel 0 Steel (]Not Observable [�Not pplicable 403.1.1 Programmable thermostats Q Complies [FIg]2 installed for control of primary heating and cooling systems QQ Does Not and initially set by Omply manufacturer to code Not specifications. I servable (1 Not t• pplicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium impact(Tier 2) 3 Low Impact(Tier 3) Report Title:Jones Residence Report Date: 1/5/26, 1:28 PM 11 of 12 2024 IECC Energy Efficiency Certificate Above-Grade Wall 23.50 Below-Grade Wall 0.00 Floor 0.00 Ceiling/Roof 32.50 Ductwork(unconditioned spaces): _ . . . s Window 0.28 0.32 Door 0.28 Skylight 0.00 Cooling Heating System: Cooling System: Water Heater: Name: Date: Comments: r Report Title:Jones Residence Report Date: 1/5/26, 1:28 PM 12 of 12 COMPLY WITH ALL CODES O TOWN CODES F rt i A REQUIRED W YORK TAN &D CONDITIONS OF i SOUTH OUTHOLD TOW'V PLANNING BOARD PLANNING -'t' '- ` ( r' !;^.Iv` N.Y.S.DEC r `:, G i i • 1 TRUSS PLACARDING REQUIRED ___..._� /S nXr �fN�j�1J W��! To �:oMp�y w►,�-i i 1Ja 50 i . p 1 ^" ! �C-7`•L'IPf C E �� f�is�i. I�FAM r S.1/,(FIE FAM1� :FZt{ CF 9 t`� I //0 SyMkJ 341VE rtJ,).! FZ 1 i FpOJb�,cD f I ADD NNE J -FLOO(�1N(- 7; rO A-D> Z ` 12, NISN IJ-4(,c1 wry'' 2,-4 �-79 1 Avv : l/1LC PEv+pd, N.S..f.. -- ,I F � UlJ++,�tSN�? IJ1�c l S - �x�s?��� '•, � �P�(�°F ��W r� yo a ., �OFESSIONP� Table 3.1 Nailing Schedule(Wood Framed Construction Manual 2018,Page 149) Framing Notes: Number of Number of LEGEND: Joint Description Common Nails Box Nails NailSpacing ROOF NAILING The contractor is to verify all measurements in the field and any discrepancies are to be brought to the attention Rafter to Top Plate(Toe-nailed) 3-1 od 3-16d per rafter of the Engineer prior to construction. I. WINDOW AND DOOR HEADERS TO BE(2) 2X8 HEADERS WITH(2) 2X STUD POST Ceiling Joist to Top Plate(Toe-nailed) 3-1od 3-16d per joist Wood Framing UNLESS OTHERWISE SPECIFIED ON THE Ceiling Joist to Parallel Rafter(Face-nailed) 10-16d 10-40d each lap PLANS. Ceiling Joist Laps Over Partitions(Face-nal� 10-16d 10-40d each lap 1. All lumber is to be No.2 or better Douglas Fir Larch(N)with the following minimum specifications: Collar Tie to Rafter(roe-nailed) 3-16d 4 40d per tie Blocking to Rafter(roe nailed) 3-8d 3-10d each end Fb=825 psi 2. ALL POSTS TO BE(2)2X STUD POSTS AT Rim Board to Rafter(End Nailed) 3-16d 4-10d each end Fv=95 psi ALL HEADERS AND BEAMS UNLESS Rafter to ridge,valley or hip rafters 3-10d 3-16d toe or end nail ,� .. WALL FRAMING Fc peril=625 psi �,� «. $�,` OTHERWISE SPECIFIED ON THE PLANS. E=1,600,000 psi t,,.,1 Top Plate to Top Plate(Face-nailed) 3-16d 3-16d per foot /"i e Top Plates at Intersections(Face-nailed) 4-16d 5-16d joists-each side 2. AD Laminated Veneer Lumber is to have the following minimum specifications: %�` Design Loads: Stud to Stud(Face-nailed) 3-16d 3-16d 24'o.c. EX.2X6 RR @ 167 O.C. Header to Header(Face-nailed) 16d 16d 16'o.c.along edges Fb=2,900 psi -Roof-Live Load-30 (SISTER 3-2X8 AT EACH J�OtST) psf Based on ASCE-7 and Top or Bottom Plate to Stud(End Nailed) 3-16d 3-16d per stud Fv=290 psi Pg=25 psf per Figure R301.2(5) Stud to Stud at abutting studs at intersecting wall comers 16d 16d 17 o.c.face nail Fc perp=650 psi APPROVED AS NOTED _Dead Load-30 psf TURNBUCKLE Continuous header to stud 4-8d 5-8d toe nail � (LOCATION BY ARCHITECT) Bottom Plate to Floor Joist,Band Joist,End jooist or Blocking(Fake-Nailed) 2-16d 3-16d per foot E=2,000,000 psi DAT • ',/' B.P. 2�7 _1 st Floor -Live Load -40 psf SiMPSON HTT4� SIMPSON H1T4 3. An Laminated Structural Lumber is to have the following minimum specifications: FE 6 5:00 BY: -Dead Load-15 psf FLOOR FRAMING NOTIFY BUILDING DEPARTMENT AT Joist to Sill,Top Plate or Girder(Toe-nailed) 4-8d 4-10d per joist Fb=2,800 psi 631-765-1802 8AM TO 4PM FOR THE -Wind Loads-130 mph-ASCE-7 Bridging to Joist(roe-nailed) 2-10d 2-10d each end Fv=290 psi FOLLOWING INSPECTIONS: qh=25.8 psf(Exposure B) EYE h�rr5 7B'0 STEEL Roo Blocking to Joist(roe-nailed) 2-8d 2-10d each end Fc perp=740 psi 1. FOUNDATION-TWO REQUIRED Roof C&C Loads: Blocking to Sill or Top Plate(roe-nailed) 3-16d 4-16d each block E=2,100,000 psi FOR POURED CONCRETE 43.3 psf(Zone 1) Ledger Strip to Beam(Face-nailed) 3-16d 4-16d each joist 2. ROUGH-FRAMING&PLUMBING -50.2 psf(Zone 2) Joist on Ledger to Beam(roe-nailed) 3-8d 3-10d r joist 3. INSULATION -61.0 psf(Zone 3) g (T ) per jo 4. All treated lumber is to be No.2 or better Southern Yellow Pine with the following miniiurrl jR rf MMTRUCTION MUST Band Joist to Joist(End-nailed) 3-16d 4-16d per joist Band Joist to Sill or Top Plate(Toe-nailed) 2-16d 3-16d per foot 2T-0' Fb=975 r BE COMPLETE FOR C.O. Wall C8C Loads: ALL CONSTRUCTION SHALL MEET THE -31.6 psf(Zone 4) ROOF SHEATHING Fv=175 psi FIEQUIREMENTS OF THE CODES OF NEW Structural Panels 8d 10d See roof sheathing Fc perp=565 psi YORK STATE. NOT RESPONSIBLE FOR -38.0 psf(Zone 5) nailing detail on E=1,600,000 psi DESIGN OR CONSTRUCTON ERRORS THIS BUILDING IS DESIGNED AS AN ENCLOSED structural sheets STRUCTURE. NOTES: CEILING SHEATHING 5. All beams fabricated with multiple Laminated Veneer Lumber boards are to be nailed/bolted in accordance *INSTALL 7/ErO STEEL TiE RODS 6-6'INCHES ON Gypsum Wallboard 5d coolers 5d coders T edge/T field with the manufacturer's s CENTER MAX specifications. Design Criteria-INYS Residential Code R301.2.1.1 and utilized the SIMPSON LSTA36 WALL SHEATHING 6. All wall sheathing is to be 23132 inch APA Rated Exposure 1 plywood and shall be fastened to the studs as methods and procedures stipulated in Chapter 2 Engineered Design and*POSMON TiE RODS WITHOUT SAG BY STRAP Structural Panels 8d 10d 6"edge/IT field per the nailing schedule on this sheet. Chapter 3 Prescriptive Design in the American Forest and Paper Structural Fiberboard Panels 1/7 11 ga.gale.roofing naff OAT x 1 tr1'iong 7n6' 3'edge/6"field Association Wood Frame Construction Manual for One and Two Family SECURED THE CABLES TO ROOF Dwelling Units-High Wind Addition and ASCE 7. Structural Fiberboard Panels 25132' 11 ga.galy.roofing nab 0. T x 1 wr�3Ar head 3'edge/6'field 7. Solid blocking g g RAFTERS ABOVE DURING TENSIONING USING THE 9 g is to be installed every 8 max or mid span of all floor joists with spans exceeding 8'. TURNBtUCKLES. Gypsum Wallboard 5d coolers 5d coolers T edge/T field Particle Board Panels 8d 8d Per Manufacturer 8. Double joists are to be installed below parallel walls. *TURN'BUCKLES AND EYE NUTS ARE CLEVELAND FLOOR SHEATHING CiTY FORGE PRODUCTS OR EQUIVALENT. Structural Panels 9. Blocking is to be installed at all point load bearing points. SCOPE OF WORK: TYPICAL WINDOW AND DOOR HEADER 1'orless 8d 10d 6'edge/I?field Greater than 1' 10d 16d 6'edge/12'field 10. Walls are to be framed with 2x6 inch studs spaced 16 inches O.C.unless indicated otherwise. 1. Remove ex.ceiling joists from living room and kitchen. COLLAR TIE DETAIL STRAPPING DETAIL EACH CORNER (1)Nailing requirements are based on wall sheeathing nailed 6'on-center at the panel edge. Altemate nailing schedules shall be used where wall sheathing nailing is redu(xed. For example,if wall sheathing is nailed 3 inches on-center at the panel edge 11. All plates,bolts,nails,etc.are to be galvanized or stainfesssteel. 2. Install new,collar ties in living room and kitchen. SCALE 114•=r-tr NTS to obtain higher shear capacities,nailing tequi irements for structural members shall be doubled,or alternate connectors shall be used to maintain load path. 12. Designated connectors,straps,hold downs,etc.specified an these drawings are made by Simpson unless 3. Removal of interior walls to be removed and installation of new framing (2)When wall sheathing is continuous over connected members,the tabulated number of nails shall be permitted to be indicated otherwise. All connectors,straps,hold downs,etc.are to be nailed/bolted in accordance with the reduced to 1-16d nail per foot manufacturer's specifications and installed to the maximumrated capacity. 4. Installation of new windows and doors 13. Afl joist and beam hangers and fasteners used on the exterior are to be Simpson 316 Stainless Steel as 5. Installation of insulation in all walls,floors,and roof areas. required by Simpson. All straps and hangers located in prdected interior locations are to be galvanized. 6. Installation of a new kitchen,bathroom and associated plumbing and 0 14. All bolts nuts and washers are to be stainless steel or hot duped galvanized. electrical niodifications and additions. 7. Installation of gypsum and finishes - Simpson LSTA30 Ridge General Notes: Strap at each Rafter 1-Occupancy classification-Residential Group R-3 2-Type 5-Wood framed construction to be utilized. WINDOW AND DOOR NOTES: 3-Building height-IT-10',fire area-1,368 s.f. 1. Contractor to)verify all window and door openings prior to ordering new windows. 4-Design Criteria-NYS Residential Code R301.2.1.1 and utilized ther methods and procedures stipulated in Chapter 2 Engineered Design and Chapter 3 Prescriptive Design in the American Forest and Paper Association 2• Windows and doors are to be wood with double pane insulating Wood Frame construction Manual for One and Two Family Dwcifing Units-High Wind Addition and ASCE 7. high-performance low E glass with a max U value of 0.28 and an SHGC of 0.32. 5-No plumbing or electrical work is planned for this project. 3. 2-Windows and doors are to conform with the Allowable Air Infiltration Rates specifiied in the 2024 IECC. 4. 3-Windows and doors are to be equipped with removable plywood panels as shown on the detail sheets or shall meet the requirements of the Large Missile Test of ASTM E 1996 for 130 mile per hour wind loads. 5. 4-Windows shown are manufactured by Anderson 400 series. 6. 5-All bedroom windows have free openable area of 5.7 s.f. SIMPSON LSTA36 TOP PLA S SIMPSON LTP STRAP HEADER Typical Wall and Sill OR Strapping Detail SIMPSON MTS310 RAFTER STRAP OR FTE AT EACH RAFTER TAIL SIMPSON H2.5A RAFTER REVISIONS TAIL TO TOP PLATE SIMPSON TSPZ STRAP CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA SIMPSON H2.5A TOP FASTEN EXTERIOR SHEATHING TO TOP AND BOTTOM PLATE SIMPSON SDWC15450 Ground Snow Load Wind Speed Seismic WeatheringFrost Line Termite DOUBLE ROW 8d COMMON NAILS @ 6'O.C. Wmi E COAT Decay Winter Design Ice Shield Food Hazards H2A � TOPS PLATE TO STUD S THING PANELS 0 OVERLAP TOP MEMBER OF Depth Temp. Underlayment STU W 0 GALV.ANCHOR BOLT WITH A THE TOP PLATE AND BOTTOM PLATE BY 1112'. SIMPSON BP518-3 BEARING PLATE wired SIMPSON H2A HURRICANE TiES XT 2-SIMPSON H2.5A HURRICANE TIES • FASTENER ROWS TO BE 11T APART WITH A 1/2'MIN. 20 psf 130 mph A Severe 36 in. Moderate Slight to 11"F None NIA EACH RAFTER TAIL(INSTALLED OIN AT EACH RAFTER TAIL(INSTALLED ON EDGE DISTANCE 2-SIMPSON H4Z STRAPS to Heavy Moderate EXTERIOR SIDE ONLY) INTERIOR SIDE ONLY) • EACH ROW TO HAVE NAILS AT SPECIFIED SPACING. Plans are prepared by Condon Engineering,P.C. It is a viaration of the New York State Education Law,AnSde 145,Section 7209,for any person unless acting urder Im direction of a licensed Professional Engineer,Architect,or Land Surveyor,to after any Rem in any way.f f an item bearing the seal of an Engineer,Architect or Lard Surveyor is allered,the aRerirg Engineer,Architect or Land Surveyor shall affix to the item his w seal and the notation'Altered by'followed by his."signature and the date of such TYPICAL WALL AND SILL STRAPPING DETAIL alterations,and a specific description of the alteration. Scale:AS SHOWN Condon En ineenn , P.C. JONES RESIDENCE 9 9 110 SYLVAN LANE by.JJC Drawn 1755 Sigsbee Road EAST' MARION, NEW YORK TYPICAL BUILDING SECTION Mattituck,New York 11952 Vh NOT TO SCALE (631)298-1986 (631)298-2651 Fax (NOTES AND Date:1/4/202s www.condonengineering.com SPECIFICATIONS I� I I 1 1 1 I 1 , t — — I I I 'I I I I IarcrEN I I I I n BEDROOM 2 8'-0'CLG v F-W CLG sinH=sue•• I BATH I I I V-0 CLGT-y L - JI I I WANG ROOM u 11 1 1 1 V-W CLG I 'L PROPOSED ( I }i i VAULTED CEILING I q iii i ii II ❑ BATH I I N I BEDROOM 1 8'-0'CLG / \ II 8'-0'CLG I - -- --- --- {-- -- -- - - - - - - - S�H=.•�. I I � SDI H�'-0". G� H S"v I r- H;�'S' I— n x � I Sin H=2S I I I "ROM I9-T CLG I I fl I O I I M I I I S6i1 H=V-11T sines 1'-to' I L -. J REVISIONS Plans are prepared by Condon Engineering,P.C. ft is a violabov of tie Nm Yak State Education Law,Article 145,Section 7209,for any person unless acing mler the direction of a licensed Professional Engineer,Architect,or Land Surveycor,to alter any Rem in any way.If an Item bearing tie seal of an Engineer,Architect,or,Land Surveyor is altered,the altering Engineer,Architect or Land Surveyor shaft affix to the item hMw seal and the nota5an'Aftered by'folowed by Wier signature and the(date of such afteratio s,and a specific description of the afteratan. Scale:ASSHOVM Condon En ineedn , P.C. JONES RESIDENCE 9 9 110 SYLVAN LANE 1755 Sigsbee Road EASY MARION, NEW YORK Drawn by��� Mattituck,New York 11952 (631)298-1986 (631)298-2651 Fax Date:1/4/2026 www.condonengineedng.com EXISTING FLOOR PLAN i WINDOW TO BE WINDOW TO BE REPLACED IN KIND REPLACED IN KIND TW2632 DOOR TO BE TW2636 R30 OPEN CELL INSULATION RO 7-81/8'X 34 7/8' REPLACED IN KIND RO 7-01/8'X T-8 70 M VAULTED CEILING INSTALL BAFFLES BETWEEN RAFTERS �— I WINDOW TO BE i DW 30'RANGE NEW ANDERSON WINDOW REPLACED IN KIND I I ------- _ _ RO 517/8'X 40 7/8' TW2632!RO 7-8 1/8'X 3'4 7/8' R21 FIBERGLASS INSULATION IN WALLS ---- I - -- - I (BETWEEN VAULTED ROOMS ANDUj I Uj EX.WINDOW TO ATTIC) KITCHEN I I I a RE]NAIN BEDROOM 2 94r CLG I I I BEDR001�2 l3 ci¢ i REMOVE CEILING JOISTS IN 8'-W CLG PROPOSED I I PROVIDE STORAGE SPACE WITH8,-0.CLG N ( HATCHED AREA VAULTED CEILING HIDDEN SHIP LAP COVER r I I WINE DOOR TO BE I —— REPLACED IN KIND INSTALL 2X4 STUD WALLS IN I REF. STORAGE I ATTIC AROUND VAULTED I �' L— CEILING I I NEW BARN DOORfINCR I [IL I I ggT}f BATH V-W CLG — — J x REDUCE CLOSET R21 FIBERGLASS 8't)'CLG L NO WORK •J SIZE INSULATION IN WALLS `J \O w 1` NEW ANDERSON WINDOW0 r------ I TV4210210 i i RO 36118'X 48 7/Ir I I I 1 m1 N LNMG ROOMPROPOSED NEW ANDERSON WINDOW(ABOVE)WINDOW TO ND VAULTED CEILING TW2446(RO 25 718'X 241/4' i i _ �REPLACED IN KIND N TI1 M7M/p2� � J J J Q RO7-81B'X3'471 a NEW ANDERSON WINDOW00 _ TV1210210 x RO 36 118'X 48 71r I I INSTALL 2X4 STUD WALLS IN y I ATTIC AROUND VAULTED _ CEILING i v PROPOSED Ti X 6' BEDROOM 1 BATH o BEDROOM 1 BATH SLIDING DOOR 9-W CLG Q 94'CLG Lu fUVG6068I- 8'-0'CLG ( = I 94'CLG v NO WORK co x ® NEW ANDERSON WINDOW N TW210210 I R21 FIBERGLASS INSULATION IN WALLS RO 3610 X 48 7/8' (BETWEEN VAULTED ROOMS AND ( I / v I WINDOW TO BE ATTIC) REPLACED IN KIND R30 OPEN CELL INSULATION — — — — — — — — ——TW2632 IN VAULTED CEILING —— — ——— ——— ——— --- — — — —— — — — —CLG-slope— — — — —— —— RO 7-8118"X 3'-4 718' INSTALL BAFFLES BETWEEN H,='-0' RAFTERS I tc srope H CLOSE UP OPENING H, F I WINDOW TO BE REPLACED IN KIND I TW28310 RO 2-101/8'X T4r 7B' (2j 2X10 HEADER WINDOW TO BE I I I NEW ANDERSON WINDOW REPLACED IN KIND TW 38510 TW18210 I I I RO 6'-0 7/8'X 3'-101/8' R01'-10118'X 3'-0 7/8' i SUN ROOM ` "ROM 8'-3'CLG I ( 8'-3'CLG i DOOR TO BE REPLACED IN KIND I I I IR38 FIBERGLASS INSULATION IN CEILING WINDOW TO 13E REPLACED IN KIND WINDOW TO BE RO 120 7/8'X 60 3/8' REPLACED IN KIND ( I I R0 717/8'X 60 3/8' R21 FIBERGLASS I INSULATION M WALLS — I R21 FIBERGLASS L INSULATION IN WALLS WINDOW TO BE WINDOW TO BE REPLACED IN KIND REPLACED IN KIND RO 717/8'X 60 7/8' R0 7178'X 60 7/8' PROPOSED FLOOR PLAN PROPOSED FRAMING PLAN REVISIONS Plans are prepared by Condon Engineering,P.C. It is a violation of the New York Stale Education Law,Article 145,Section 7209,for any person unless acting under The direction of a licensed Professional Engineer,Architect,or Land Surveyor,to after any item in arty tray.If an utem bearing the seal of an Engineer,Architect,or Land Surveyor is altered,the altering Engineer,Architect,or Land Surveyor shall aft to the item hisPoer seal and the notation'Aftered by'followed by hi Aw signature and the date of such alterations,and a specific description of the alteration. Scale:AS SHOWN Condon Engineering, P.C. JIONES RESIDENCE 110 SYLVAN LANE 1755 Sigsbee Road EAST MARION, NEW YORK AdElk Drawn by.JJC Mattituck, New York 11952 (631)298-1986 (631)298-2651 Fax WM3 Date:1142M www.condonengineering.com PROPOSED FLOOR PLAN II 1 EX ROOFING TO REMAIN EX SIDING TO REMAIN EX ROOFING TO REMAIN DOOR TO BE NEW ANDERSON WINDOW TW2446(RO 25 7/8'X 241141 REPLACED IN KIND EX SIDING TO REMAIN ----------------------------------� — --�,----��------t �► I I I I II I I I I t NEW ANDERSON WINDO' t I I I i I I I I RO 517/8'X 40 7/8' DOOR TO BE t i i i i i REPLACED IN KIND -- t WINDDWTOBE Ll WINDOW TO BE ° REPLACE)IN KIND = REPLACED IN KIND TW2632 TW2636 RO Z-81M X 34 7/8' NEW ANDERSON WINDOW RO 7-8118'X T-8 7/8' EX WINDOW TO TW210210 REMAIN WINDOW TO BE —REPLACED M KIND RO 120 7/8'X 60 3/8' FRONT ELEVATION RIGHT ELEVATION EX ROOFING TO REMAIN EX SIDING TO REMAIN PROPOSED 6 X Vr SLIDING DOOR FWG6068L WINDDW TO BE WINDOW TO BE REPLACED IN KIND REPLACED IN I4ND RO 717/8'X 60 3/8' R02-011WX3'47/8' o It 11 WINDOW TO BE I I I I REPLACED IN KIND j TW2632 RO 7-81/8'X 34 718' I II II II It II tt II WINDOW TO BE REPLACED IN KIND NEW ANDERSON WINDOW TW2632 TW 38510 WINDOW TO BE RO 7-81/8'X T-4 7/8' DOOR TO BE RO 6'-0 7V X 3'-101/S' REPLACED IN KIND REAR ELEVATION REPLACED IN IaND TW28310 WINDOW TO BE RO 2-1011W X 4'-0' 7Ar REPLACED IN I4ND WINDOW TO BE RO 717/8'X 60 7/8' REPLACED IN KIND REPLACED IN KIND RO 71718'X 60 7/8' TW18210 R01'-101/8'X T-0 7/8' LEFT ELEVATION REVISIONS Plans are prepared by Condon EmOneeriM,P.C. It is a violation of fte New Yak State Education Law,Article 145,Section 7209,for any person urhless actimg under the direction of a licensed Professional Engineer,Architect,or Land Sm eyor,to after any item in arty way.If an item bearing the seal of an Engineer,Architect or Land Surveyor is altered,the altering Engkmw,Architect,or Land Surveyor shaft afro tto the item his w seal and the notation'Aftered by,foflowed by hislher signature and the date of such afteratbns,and a specific desaip m of the afteration. Scale:AS SHOWN Condon En ineedn PC JONES RESIDENCE 9 9 . . 110 SYLVAN LANE 1755 Sigsbee Road EAST MARION, NEW YORK Drawn by.JJC Mattituck, New York 11952 (631)298-1986 (631)298-2651 Fax zim4 Date:114/2026 wm.condonengineedng.com BUILDING ELEVATIONS