Loading...
HomeMy WebLinkAbout51997-Z ~o��pf SOUPyy`o Town of Southold * * P.O. Box 1179 410 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 47286 Date: 08/13/2026 THIS CERTIFIES that the building ACCESSORY-NEW STRUCTURE Location of Property: 8255 Bridge Ln Cutchogue, NY 11935 Sec/Block/Lot: 84.-1-4.6 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 02/20/2025 Pursuant to which Building Permit No. 51997 and dated: 06/16/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Accessory pool house with covered porch, half bathroom, and attic storage as applied for. The certificate is issued to: Richard Sachs Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: R-24-0943 6/24/2026 ELECTRICAL CERTIFICATE: 112563 7/29/2026 PLUMBERS CERTIFICATION: Joseph J Tuomey 4/22/2026 utho ' ed ign tune *-fSolo/ o�c TOWN OF SOUTHOLD * BUILDING DEPARTMENT • TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51997 Date: 06/16/2025 Permission is hereby granted to: Richard B Sachs PO BOX 1261 Mattituck, NY 11952 To: Construct a pool house with covered porch accessory to a single-family dwelling as applied for per Historic Preservation Commission and SCHD approvals Premises Located at: 8255 Bridge Ln, Cutchogue, NY 11935 SCTM#84.4-4.6 Pursuant to application dated 02/20/2025 and approved by the Building Inspector. To expire on 06/16/2027. Contractors: Required Inspections: Fees: Accessory-New Structure $375.00 CO Accessory Structure $100.00 Total $475.00 Building Inspector u lASSAU ELECTRICAL 4 416 SUFFOLK INSPECTORS p 159 Route 25A,Building 1 Suite B Miller Place,NY 11764 Telephone:631 495 8136 ? Fax:631 509 4538 ? E-Mail: Info@SuffolkBEI.com CERTIFICATE OF ELECTRICAL COMPLIANCE Applicant: Wildwood Electric Inc Certificate No.: 112563 Rough In Inspection Date: Sep 11,2025 Final Inspection Date: Apr 21,2026 Application No.: Building Permit No.: 51711 51997 51999 � County Tax Map No.: 084.00 01.00 004.006 pry. a This Certificate of Electrical Compliance is limited to the inspection and compliance of electrical equipment and/or work described below,installed on behalf of the applicant named above, located at the premise of and not after the final inspection date above: Owner: Richard Sachs Site Location: 8255 Bridge Lane,Cutchogue,NY 11935 Owner's Address(if different): x❑Residential indoor Basement Qx Service Shed Commercial Outdoor First Floor Pool Hottub �x New ❑Renovation Second Floor Qx Attic/3rd Floor Garage ❑Addition ❑Survey PV Solar �x Generator Conversion Signs Battery Storage ❑Safety Inspection Other:Pool House INVENTORY Single Phase Heat Gas Duplex Recpt 116 Ceiling Fixture 236 Dual Func Breaker 45 i Three Phase Hot Water Gas GFCI Recpt 21 Wall Fixture 28 Smoke Main Panel AC Cond F____1 Single Recpt F---] Recessed Fixture CO Detect 14 Sub Panel AC Blower Range Recpt LED Lighting 153 Smoke CO Combo Transformer Appliance Ckt 12 Dryer Recpt Emergency Time Clock s' Disconnect Switches 31 Twist Lock Exit Fixtures Pumps GFCI Breaker Heat Pump Electric Heat Pool Luminaire F4__� Exhaust Fan Other Equipment:600 amp underground service/1-100 KW generator with 2-ATS Permit 51711(House)Permit 51997(Pool House)JPermit 51999(Generator) The electrical work and/or equipment described above were inspected and was found to be in compliance with local, ;r state and national electrical code requirements and this office. Applicant: Wildwood Electric Inc License No.: 4836 Date Printed: Jul 29, 2026 Inspected I Signature: Poo I h o us e- Town Hall Annex a� y� Telephone(631)765-1802 54375 Main Road P.O.Box 1179 y = Southold, NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATION Date: Y12-2-12— Building Permit No. J-1 01 9 7 Owner: i C k atzd 18 SA C h s (Please print) Plumber: J 0 St' Z— —FIA t) VYl }{ea-4 I lv n� (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1%lead. (Plumbers Signature) Sworn to before me this Z Z day of_Ap r l 20_;7n� 300— --\j Notary Public, SL,-F-fo l lC County JOHN P LICCIARDO NOTARY PUBLIC -STATE OF NEW YORK #. NO. 01L16259018 ,l* QUALIFIED IN SUFFOLK COUNTY MY COMMISSION EXPIRES APRIL 02, 2028 g SOUTho� # # TOWN OF SOUTHOLD BUILDING DEPT. co 631-765-1802 INSPECT ON UNDATION 1 ST/ REBAR [ OU H PLBG. [ ] �F�QATION 2ND [ SULATION/CAULKING [1,100FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] -FIRE SAFETY INSPECTION [ -] FIRE RESISTANT.CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ .] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: — ��—o (46��� l "'? fu"., C6� ls�wv 0 ILVI_� f;4� T 6j� � O ma�� gem DATE Y� : INSPECTOR qf SOOjy�lo # # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I ULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: 1 ��ImAtel 5vYV0AA -v (( hy\�O,-) vxk,(� 4n (1/1 ral DATE INSPECTOR # TOWN ,OF SOUTHOLD BUILDING DEPT. cou�m 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ZROH PLBG. FOUNDATION 2ND [ ATION/CAULKING FRAMING /STRAPPING [ [ FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION' [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODEVIOLATION [ . ] PRE C/O [ ] RENTAL lQ�REMARKS: C� �'tICYIC� G� DATE )�q R�M1M1ttkt'����ddl���ei it °ti E" a ®elfino Insulation Co. Inc. � y �r 317 Burman Blvd,Calverton,NY 11933 CERTIFICATE OF INSULATION 10B INFO: SACHS,RICHARD DATE OF INSTALLATION: 08/05/25 8255 BRIDGE LANE CUTCHOGUE,NY 19935 POOL HOUSE. ATTIC ROOFLINE 2X6 EXTERIOR WALLS INSULATION TYPE INCHES R-VALUE INSULATION TYPE INCHES R-VALUE ❑ OPEN CELL FOAM ❑ OPEN CELL FOAM (] CLOSED CELL FOAM 2" R-14 I] CLOSED CELL FOAM 2" R-14 ❑ FIBERGLASS [] FIBERGLASS [] CELLULOSE ❑ FIBERGLASS GABLE WALLS SOUND 1STFLOOR CEILING INSULATION TYPE INCHES R-VALUE INSULATION TYPE INCHES R-VALUE ❑ OPEN CELL FOAM ❑ OPEN CELL FOAM CLOSED CELL FOAM 2" R-14 ❑ CLOSED CELL FOAM ❑ FIBERGLASS 0 FIBERGLASS 10.25" R-30 UNFACE ❑ CELLULOSE [I MINERAL WOOL ATTIC ROOFLINE 2X6 EXTERIOR WALLS INSULATION TYPE INCHES R-VALUE INSULATION TYPE INCHES R-VALUE ❑ OPEN CELL FOAM ❑ OPEN CELL FOAM ❑ CLOSED CELL FOAM ❑ CLOSED CELL FOAM 0 FIBERGLASS 10.25" R-30UNFACED 0 FIBERGLASS 3.5" R-15 UNFACE ❑ MINERAL WOOL ❑ MINERAL WOOL GABLE WALLS INSULATION TYPE INCHES R-VALUE INSULATION TYPE INCHES R-VALUE ❑ OPEN CELL FOAM ❑ OPEN CELL FOAM ❑ CLOSED CELL FOAM ❑ CLOSED CELL FOAM FIBERGLASS 3.5" R-15 UNFACED ❑ FIBERGLASS ❑ MINERAL WOOL E] MINERAL WOOL p FIRE CAULKED TO CODE DATE OF INSTALATION: 08/05/25 ❑ FIRE BLOCKED TO CODE DATE OF INSTALATION: N/A O AIR SEAL SUBSTATE TO CODE DATE OF INSTALATION: 08/05/25 ❑ IGNITION BARRIER TO CODE DATE OF INSTALATION: N/A ❑ THERMAL BARRIER TO CODE DATE OF INSTALATION: N/A I Maria Hoti certify that the residence referenced above was insulated as per signed proposal by builder/homeowner,and the installation was conducted in conformance to applicable codes and standards and regulations. AUTHORIZED SIGNATURE Bunch, Connie �1 From: Dwyer, Tracey Sent: Tuesday, August 11, 2026 5:12 PM To: Bunch, Connie Subject: HPC 8255 Bridge Lane ASIP-Sacks, 8255 Bridge Lane—1000-84.-1-4.6 Via photos and emails it has been determined by the HPC members that the subject improvements at 8255 Bridge Lane, Cutchogue, have been completed to their satisfaction . Tracey Dwyer Building Permits Examiner Town of Southold (631) 765-1802 1 r'IELD INSPECTION REPORT DATE. / COMMENTS _ m 1 UUNDA"PION (IST) FOUNDATION (2ND) 1< 4 c>o 6 ROUGII FRAMING & --- - s �` . . ---Clc c1k PLUMBING ......... .. . .. C� r INSULATION PER N. Y. STATE ENERGY CODI, ......... CA FINAL .. _ -- -- ---- ------_------- q(A- yf- ADDITIONAL COMMENTS 60 h � o -----. . .. _ _ .- - ..__. ._ cri �y _ C7 • v� °ffo�'r_\�y TOWN OF SOUTHOLD—BUILDING DEPARTMENT ca Town Hall Annex 54375 Main Road P. O. Box 1179 Southold, NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny.goov_ Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only ,, PERMIT NO. I 1 Building Inspector: 'Y�) FEB 2 0 2025 Applications and forms must be filled out in their entirety. Incomplete a,ppliGations will not be aecepte,q. Where the Applicant snot.the owner:.an. Owners Authorization form(Page 2)shall be completed. � U D' 2025. l! Date: . 2_ . O.WNER S. OF PROPERTY: Builaing CUP - TC,_,In of Southold Name::.�.I . Q:. SCTM#1000- DS_l D1 - �. 6 Project'Address: Phone#: (WO i yZ�_/7'50 Email: 5 _ Mailing Address: P.0. BOX 12,6 6 I - — _CONTACT PERSON: -.- Name: WJ. U:�-64 j Mailing Address: AAJ Phone#: C�3i� 338-$� Email: ? .e DESIGN PROFESSIONAL INFORMATION: Name: D M Mailing Address: L.` � g Phone#: G�3 3 C3,i, Email: CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF:PROPO 11)CONSTRUCTION New Structure ❑Addition ❑Alteration ❑Repair C(Uemolition Estimated Cost of Project: ❑Other $ Will the lot be re-graded? ❑Yes DAo Will excess fill be removed from premises? ❑Yes Leo �- 1 PROPERTY INFORMATION Existing use of property: GF Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to Ac this property? ❑Yes Mo IF YES, PROVIDE A COPY. - ��heC1C BOX After Reading The oiwner/contractor/design professional is responsible,forsll drainage and storm water issues as provided-by Chapter 2A of the Town Code APPLICATION IS HEREBY MADE to the;Builtlmg Department for the issuance of a Building Permit pursuant to the Bwldmg Zone.. Ordinance of the Town of Southold Suffolk County,New Yorkyand other appheable Laws Ordinances or Regulations;for the construction of bwldmgs additions;altera4ionsor or..re demoktion as herem:descnbed a The applicant agrees to comply with all pplicable laws,ordinances,building code, housing code and regulationsand t6admrt #honied buiId inspectors onpremises and m i (s)fa r necessary mspeetions False statements made here�ri are au unishable as a Class A misdemeanor ursuant to Section 210 4S of the New York State Penal Law Application Submitted By(print name):. ITE&Luthorized Agent ❑Owner - —- ---_ _ Date.-.._. -pp_ - 777 T. —_.. - ":ELL STATE OF'NEW YORK) _.. SS - - T. COUNTY OF. _ _ betj ing duly sworn;deposes and says'that(s)he is the applicant-- (Name of iridividual•signiing-contract) above-earned; ____'_::. _..._,._... ___._._____ ,__.__..... _....._.....- -.,.._.-_.. _..__•.-___ --- --- ---- --—---- --- - - 97 .�..=- - -;'- Contractor;-Agent; Corporate Officer,etc.) of said owner orowners=and is duly a"uthorized to perform or liave performed the said work and to make and flethis -- - _ _ application,that all statements contained In Phis application.are true to.the best of_hi' /her knowledge=and=belief;and = - that, he.iiuo%k wlll be erfcirr ed_in tla"e a .an bKset,-d.rth inAh appJlcat�on.fil.e,:ther_ewith, --: _ =-Sworn before me this l{ 'jay. - -(� / ofar"y Public - HILLARY ANNE HUBBARD. -- - _ Public=$gate of NewM k--- - -- -------- - - - _ - No OaHU6A34316---- --_ AUTHORIZATION-- Qualilied in Suffolk County (Where the applicant is not the owner) My Commission Exp.09/06/2026 I, �� �- residing at 0• OCV 1 fo) 1)915 do hereby authorize / J f bSV �&TLJ�n- to apply on my h to the T w u Building Department for approval as described herein. Z III_ 0 r s Sig re Date Print Owner's Name 2 +i. our uni94e David Mammina,Chairperson ����``� Ay Anne Surchin,Vice Chair Q 54375 Main Road,NYS Route 25 Allan Wexler n T=Cf `0 PO Box 1179 SOUTHOLD ' Unum ' Southold Marina de Conciliis ,NY 11971 Jeri Woodhouse = Wrd `r* o Telephone: (631)765-1809 Daryl Ketcham Nog I 1640 y Email: kimf@southoldtownny.gov Ahmad Sardar-Afkhami Aoo� Kim E. Fuentes,Coordinator 9FSERVATION r- Town of Southold Historic Preservation Commissio r' ? - Certificate of Appropriateness J U N 4 2025 � May 22, 2025 1300ing DOParfrnent Town €?a:30w"holff RESOLUTION #05.22.2025.1 and Amendment to #05.23.2024.2 RE: 8255 Bridge Lane, Cutchogue, NY. SCTM# 1000-84-1-4.6 Owner: Richard B. Sachs, ASIP HOUSE RESOLUTION: WHEREAS, 8255 Bridge Lane, Cutchogue,NY, is on the Town of Southold Registry of Historic Landmarks; and WHEREAS, as set forth in Section 170-6 of the Town Law(Landmarks Preservation Code)of the Town of Southold, all proposals for material change/alteration must be reviewed and granted a Certificate of Appropriateness by the Southold Town Historic Preservation Commission prior to the issuance of a Building Permit; and WHEREAS, the applicant submitted a proposal on May 13, 2025, for an approval to install a privacy fence surrounding a new HVAC Condensers and an Emergency Generator located in the side yard; and WHEREAS, the applicant also requested an Amendment of Certificate of Appropriateness #05.23.2024.2 to redesign a pool house/cabana and an in-ground swimming pool, both located in the rear yard, and surrounded by a code conforming fence previously approved by the Commission on May 23, 2024; and WHEREAS, the applicant's representative, Daniel Butler, Registered Architect, appeared before the Commission at a Work Session on May 22, 2025 to describe the proposed privacy fence surrounding the HVAC Condensers and Emergency Generator and the proposed changes to the pool house/cabana and the in-ground swimming pool; and WHEREAS,the Commission recommends that the height of the privacy fence be four feet in height; and WHEREAS,the proposed improvements are depicted in the Site Plan and Architectural Plans, Sheets A- 0.0, A-2.5, A-2.6, last revised May 14, 2025, and A-0.3, dated May 15, 2025, all prepared by Daniel Butler, Registered Architect; and Certificate of Appropriateness,Res.#05.22.2025.1 HPC, Sachs,ASIP House, 8255 Bridge Lane, SCTM No. 1000-84-1-4.6 Page 2 WHEREAS, the Commission has determined that pursuant to Chapter 170-4(E)(2) of the Southold Town Code, the Commission has the authority to determine that some proposals do not rise to the level of requiring a public hearing, as the proposal is de minimis in nature; and WHEREAS, the Commission has determined that the subject application for the Certificate of Appropriateness is de minimis in nature and therefore does not require a Public Hearing; and WHEREAS,the applicant shall submit to the Commissioners photographs of the finished improvements upon completion; and WHEREAS,the Commissioners may conduct a site inspection of subject premises once improvements are completed; and NOW THEREFORE BE IT RESOLVED, that the Southold Town Historic Preservation Commission determines that the privacy fence surrounding a new HVAC Condensers and an Emergency Generator, located in the side yard; and the Amendment of Certificate of Appropriateness #05.23.2024.2 to redesign a pool house/cabana and an in-ground swimming pool, both located in the rear yard, and surrounded by a fence,previously approved by the Commission on May 23, 2024, meets the criteria for approval under Section 170-8 (A) of the Southold Town Code; and BE IT FURTHER RESOLVED,that the Commission approves the request for a Certificate of Appropriateness, subject to approvals by all involved agencies; and BE IT FURTHER RESOLVED,that any deviation from the approved plans referenced above may require further review from the Commission. Motion made by: Commissioner Mammina Motion seconded by: Commissioner de Conciliis VOTES: AYES: Commissioners Mammina, Wexler, Woodhouse, de Conciliis, and Ketcham, Sardar- Aflchami (6-0) RESULT: Passed Please note that any deviation from the approved plans as referenced may require further review from the commission. % ` Dated May 28, 2025 Signed: �.-�- Kim E. Fuentes Coordinator for the Historic Preservation Commission � s Certificate of Appropriateness, Res.#05.22.2025.1 HPC, Sachs,ASIP House, 8255 Bridge Lane, SCTM No: 1000-84-1-4.6 Page 2 WHEREAS, the Commission has determined that pursuant to Chapter 170-4(E)(2) of the Southold Town Code, the Commission has the authority to determine that some proposals do not rise to the level of requiring a public hearing, as the proposal is de minimis in nature; and WHEREAS, the Commission has determined that the subject application for the Certificate of Appropriateness is de minimis in nature and therefore*does not require a Public Hearing; and WHEREAS,the applicant shall submit to the Commissioners photographs of the finished improvements upon completion; and WHEREAS,the Commissioners may conduct a site inspection of subject premises once improvements are completed; and NOW THEREFORE BE IT RESOLVED, that the Southold Town Historic Preservation Commission determines that the privacy fence surrounding a new HVAC Condensers and an Emergency Generator, located in the side yard; and the Amendment of Certificate of Appropriateness #05.23.2024.2 to redesign a pool house/cabana and an in-ground swimming pool, both located in the rear yard,and surrounded by a fence,previously approved by the Commission on May 23, 2024, meets the criteria for approval under Section 170-8 (A) of the Southold Town Code; and BE IT FURTHER RESOLVED,that the Commission approves the request for a Certificate of Appropriateness, subject to approvals by all involved agencies; and BE IT FURTHER RESOLVED,that any deviation from the approved plans referenced above may require further review from the Commission. Motion made by: Commissioner Mammina Motion seconded by: Commissioner de Conciliis VOTES: AYES: Commissioners Mammina, Wexler, Woodhouse, de Conciliis, and Ketcham, Sardar- Afkhami (6-0) RESULT: Passed Please note that any deviation from the approved plans as referenced may require further review from the commission. f Signed: Dated May 28,2025 Kim E. Fuentes Coordinator for the Historic Preservation Commission ,P_TO® cq UOISSIWWOD UOilenaasaJd OiaO}siH a w � a" cq W m O � 3 Q o �. � m F Wo HORIZONTAL CEDAR �+ FENCE RAILS AND CAP H/ IX6 CEDAR W/ 1.5" SPACE N O O rA C co Az _ ANIEL I 2" s� j . � 6X6 CEDAR EDAAR POST . ` V ATE OF SELF-CLOSING, SELF o LATCHNG PEDESTRIAN o GATE TO CODE, a iv O m it POURED z 4 N CONCRETE FENCE A u IN o o m FOOTING TO FROST W Fii Q p a a 4'-O"MIN, DEPTH (3'-0" MIN.) O Zd) u 4 ~ o a n M � d � oo U a � fQ L cl i FRONT ELEVATION � m D a z POOL CODE COMPLIANT MAY a0 0 FENCE AND GATE z rii TOM OF SOUTHOLI) HISTORIC PRESERVATION COMMISSION PRIVACY FENCE DETAIL PAGE: A - 0 . 3 V)6ZZ Jeffrey T. Butler, P.E., P.C. 206 Lincoln Street Architectural and Engineering Services Riverhead, NY 11901 Tel: (631) 208-8850 C E OWE Fax: (631) 727-8033 JUN 1 2 2025 Building De%partmprat Town of Southold June 11, 2025 Tracey Dwyer Building Department Town of Southold P.O. Box 1179 Southold,NY 11971 Re: 8255 Bridge Lane, Cutchogue NY (1000-084-01-4.6� Dear Ms. Dwyer, Enclosed please find revised Health Department Plans for the pool house sanitary system for your review and approval of the pool house permit. Should you have any questions,please do not hesitate to call. Sincerel BRED ARC, el A tect ! �� 030B26 OQ` ,9�F O F'NE`N If a www.dignetnycli.com (�I a Of 0 YO)FIK Ofy www.calol811.com /� EXIST. CP TO BE PROPOSED EMERGENCY GENERATOR ON CONC, SLAB, ZONING G a o \ ABANDONED PER (for other states) \ Q If / SCDHS REDS, a z BULK SCHEDULE FOR RESIDENTIAL DISTRICTS � e 800-2�2-��80 811 / PROPOSED I,000 G4�LLON IN yq / DISTRICT A-C z / GROUND PROPANE TANK FOR a w O / x 62 EMERGENCY GENERATOR o By law,excavators and contractors working in For safety reasons, homeowners are strongly X d a- the five boroughs of New York City and Nassau encouraged to call as well when planning any / EXIST. MIN. REQUIREMENTS FOR 1-FAMILY DETACHED 0 and Suffolk Counties on Long Island must type of digging on their property. Homeowners / ` EXIST. O.H. SERVICE BE ABANDONED. DWELLINGS '4�� � a contact DigNet, 1-800-272-4480 or 811, at least scan contact us directly at 1-800-272-4480 or by WELL ,p / MOVE TO NEW UINDERGROUND SERVICE z 48 hours but no more than 10 working days calling 811,the national call before you dig / LOT SIZE (SQUARE FEET) 80 000 (excluding weekends and legal holidays)prior to number. For excavation work completed on v O j o beginning any mechanized digging or excavation personal property, it is the contractor's / ¢ �Ci titi /SO, �') PROPOSED 6 BEDROOM �t 4, LOT WIDTH (FEET) 115 work to ensure underground lines are marked. responsibility—NOT the homeowner's--to contact / ¢C` ¢O O�� / }� �$ SANITARYY SYSTEM w Excavators and contractors can also submit DigNet. Having utility lines marked prior to O �Cp Q p�� �( �C 9 LOT DEPTH (FEET) 250 , „', 6 locate requests online,through ITIC. If you do digging is free of charge. 4 J (� a Q not currently use ITIC, please call �s ti� Q �Q�\ CP \ f� FRONT YARD (FEET) 60 SITE a_ o i NOTE: FOR SANITARY AND STORM DRAINAGE o 1-800 524-7603 for more information. �¢Q� �� 4' TALL PRIVACY `�/� \ �. DESIGN SEE SNIFFY SPlt2 OF THE APPROVED LOCATION a Q' FENCE GATE TO � , E PRIMARY FRONT YARD (FEET) 60 n a �. S.C,D,H,5 SITE IPLAN, S.C.D.H.S. REFERENCE Z CODE, SEE SHT. E' NO,: R-24-09431, DATED 1116/2024, SECONDARY FRONT YARD (FEET) 40tu ° a BY: McDONALD GEOSCIENCE PROPOSED CONTROL PANEL AND BLOWER: A-0,3 FOR DETAIL oy �tp' SIDE YARD (FEET) 20 u° o DATED: 3/4/2024 SEE 'CONTROL PANEL REQUIREMENTS' NOTES, Z6 '� / ,�/ \ " W _ THIS DWG. FOR MOUNTING DESIGN AND EXI ? 80 BOTH SIDE YARDS (FEET) 45 tu to EXIST. 2 STORY FRAME DWELLING REAR YARD (FEET) 15 z W o v � EL. 62.5 GRADE O.O' REQUIREMENTS CP , SEE PROPOSED 'H' FRAME DETAIL ON DWG SP2 o�,� / - � \ TO 8E DEMOLISHED o 0 EL, 61,5 DARK BROWN LOAM OL OF THE APPROVED HEALTH DEPARTMENT SET. / j \ i E � \ \ LIVABLE FLOOR AREA (SQUARE FEET PER DWELLING UNIT) 050 I BELOW GRADE \ (1)b'DIA.x ; 6'E.D. SD MAX. PERMITTED DIMENSIONS ¢ PROPOSED AC CONDENSING UNITS r N EL, 58.5 ON CONC. SLAB. / A ' \ / ' o / FP o NO WELL < SANITARY LOT COVERAGE (PERCENT) 20 BROWN SILT ML • AREA war F \, /� \ \ SYSTEMS WITHIN 150 FT. E6 EXIST. FIR SHED 3 / p NO SURFACE AGE BUILDING HEIGHT (FEET) 35/25 4 BELOW GRADE TO BE DEMOLISHED i �ti`� �, \ \ WATERS WITHIN E FT, NUMBER OF STORIES 2-1/2 p'� EXIST. FIR SHED 02 TO --/ a'DIA.x NOTES: \ LOCATION MAP ��(�\O BE DEMOLISHED $1� o N\ \ Ga �\y/ 6' E.D.5D \ 1. SEE TEXT OF CHAPTER AND DENSITY AND MIN. LOT SIZE SCHEDULES FOR 2 ¢ �4, / � ; \A end \ y \ \ APPLICABLE DISTRICTS. N.T.S. BROWN FINE SAND SP ,� �Q GP / (I)e'DIA,x i, .0, \ \ \ 4. SEE LIMITS TO GROSS FLOOR AREA (GFA) IN 280-4, 11 BBELOWLOW GRADE p 4�J� \ \ / / 6'E.D.sD �, \`� : o otie \ X TE T 5, BUILDING HEIGHT FOR ALL DISTRICTS: 35 FEET TO PEAK OF SLOPING EL, 45,5' '� / N. �.. � \ HOLE 2,9 \ ROOFS, 25 FEET FOR FLAT OR MANSARD ROOFS, SEE DEFINITIONS, NO GROUNDWATER ENCOUNTERED 10 EL, 4E5,5' PROPOSED�IEW SEPTIC SYSTED1 — \ �cti �° \ 62'5 \ 6. ROOFS MUST BE WITHIN THE SKY PLANE, SEE DEFINITIONS. SITE DATA: (47 HIGHEST EXPECTED GROUND WATER ID EL,, 11.26 PE PpR_POOL_1-IOUSE: ° ✓ c � \ SITUATE AT: WELL MONITOR STATION 553324,1 1-1000 GAL SEPTIC TANK/ s'DIA. x 8255 BRIDGE LANE I-8' DIA, X 12' E.D. LEAING DRIVE\ Y ; ` ,� 8'E.D.sD / CUTCHOGUE, NY 11935 TEST HOLE POOL / `� '6a o u \ �- (ice \ �� 'gyp COUNTY OF SUFFOLK v ° gar ' QJp TOWN OF SOUTHOLD N,T,S. 0 1� CE (v e'DIA,x \ (0 O � ? //— 150' FROM EXIST. SCTM ': 1000-084-OI-004.6 A� __ ¢q \ O ADJACENT WELL ZONING DISTRICT: A-C , EXISTING WELL TO ` .'� // LI 0)BE ABANDONED \ \ APPCANI�QWNER: p� O RICHARD B. SACHS (I)4' DIA. x 4' 4 x8 CONC. SLAB FOR \ I — — _ STEWART TITLE INSURANCE CO. W N o� L E.D.5D �\. -�, GARBAGE BIN \ \ \ a r 6ITE-DATA: AREA OF SITE: 4.3108 ACRES ,¢ O SETBACKS: lu PRINCIPAL BUILDING OR STRUCTURE, MIN. YARDS (FEET): X Z REQUIRED: EXISTING PROPOSED: 07 0 / gyp i �/ \ I FRONT = 60,0 43,5 63,5 M Q � / \ POOL FENCE EXIST. FRAME SHED *1 / x SIDE - 20.0 / 45.0 80.1 45.0 TO CODE TO BE DEMOLISHED \ / 61•g REAR = 15,0' 381.5, <15.0' lU cl0 I� / PROPOSED 11.5'x20' \ \ / \ 1 o HEIGHT= 35' / 2 STORY 2 STORY 2 STORY (28'-O") (Y- CIS / POOL CABANA W/ \ i \ / \ �fi? O O 64 COVERED PORCH - / \" 62.6 ° ACCESSORY BUILDING OR STRUCTURE, MIN. YARDS (FEET): d) (SLAB ON GRADE) i \ // / \ REQUIRED: EXISTING PROPOSED: - 0 (3)a'DIA,x 6' E.D.60 \ / \ SIDE = 25,0' 52.5' 651 R 1501 / \\ REAR = 25,0' 211.9' >25' W ' / / MAXIMUM ALLOWABLE HEIGHT FOR ACCESSORY STRUCTURE FOUR A LOT moo. \ ry�j, /i �\ 80,000 S.F OR OVER IS 22' MAXIMUM HEIGHT / PROPOSED �� 'b`�' � � / NEW WELL. \ i \ SURVEYED BY: ARCHITECT: SMITH, JUNG t GILLIS PROFESSIONAL LAND SURVEYOR tg c^//j�,© �h \ 120 MEDFORD AVENUE �� �ti�- �T<� \ PATCHOGUE, NY 11112 631-415-3192 O WELL AUGUST 11, 2022 150 FROM EXIST. AREA CALCULATIONS: ST 030B?- y(�/ ADJACENT WELL \r.�p F N - LOT COVERAGE AGE DANIEL A. BUTLER, R.A. EXISTING PROPOSED MAIN HOUSE " Q 10o_ \ \ // \ / / / \ FIRST FLOOR 1026 2929 Q SECOND FLOOR 100 1462 -f FLOOR AREA TOTAL 1806 5084 m � }- / COVERED PORCH 218 630 ('(1 REAR DECK / PORCH 199 168 Z �Ld LL UQ1 O �� GARAGE 616 ILL 0 O G� Q�\ FRAME SHED 01 246 O Z Z Z N y � FRAME SHED 02 320 1 N '6 0 (k/ (L \ 613 (/0� FRAME SHED *3 IIS N a QLUV Q POOL HOUSE 350 1 (] ul "i w N POOL HOUSE PORCH 150 H d d O Co N -1O p �. POOL Soo # ,n ¢0� TOTAL 2181 2586 5,103 ♦ OQ� Q- Q U GROSS FLOOR AREA CALCULATIONS � \ \ / ACRE SIZE 43,560 S,F, � \ \ ✓ , O 6 TOTAL LOT SIZE 4.3108 ACRES lu Z \ / H \ 181,118.448 S,F, - 80,000 101,118. 448 S.F. (Y- O 280-201 9 � (F) UP TO 2.5�o LOT AREA IN % / ,\ 200,000 S.F. 1,100 S.F. x EXCESS OF VJ FAG�E: 9 \ / 80,000 S.F, 2, 694,4612 S,F, 2,694,4612 S.F, � �SITE FLAN N \ \ / ALLOWABLE GFA %Ic34,4612 S,F. ENTIRE LOT 1 1 = 30'-0 " \ O W SC_OFE IS 10 O 30 6Q 120 \ / /'� \�\� � • GRAPHIC SCALE 1" • 30'-O" \ / v' �� 1, DEMOLITION OF EXISTING DILAPIDATED DWELLING AND ACCESSORY STRUCTURESCO �0 � j/ ,� 2, PROPOSED NEW DWELLING IN GROUND SWIMMING POOL AND DETACHED ACCESSORY, 3, RELATED UTILITY WORK INCLUDING: NEW SANITARY SYSTEM, WATER, ELECTRIC AND GAS, MAY 1 6 2025 THESE DRAWINGS AND ACCOMPANYING SPECIFICATIONS,AS INSTRUMENTS OF SERVICE,ARE THE EXCLUSIVE PROPERTY OF THE ARCHITECT AND THEIR USE AND PUBLICATION SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED.REUSE,REPRODUCTION OR PUBLICATION BY ANY METHOD,IN WHOLE OR IN PART,IS PROHIBITED EXCEPT BY WRITTEN PERMISSION FROM THE ARCHITECT.TITLE TO THESE PLANS SHALL REMAIN WITH THE ARCHITECT.VISUAL CONTACT WITH THEM SHALL CONSTITUTE PRIMA FACIE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. ►-1.._ - Ta,,,vn of sl-c)Lt:hold I' I � CAST IRON FRAME AND 6RATE/G0VER CAMPBELL IO2 G OR APPROVED EQUAL PROPOSED 1,000 PROP05ED 6 BEDROOM 5ANITARY BY: MCDONALD GEOSGIENGE FINAL 6RADE NOTE_ 5Y5TEM: DATED: 3/4/2024 ~ GALLON SYSTEM IS OVER SIZED AS PER CLIENT REQUEST CASTING •THESE PLANS ARE DESIGNED TO COMPLY WITH... UNDERGROUND (FOR AD_USTMENT •UNOFFICIAL COMPILATION OF CODE5 RULES AND RE6ULATION PROP05ED AEROBIC, TREATMENT PLANT: d OF CASTING) OF THE STATE OF NEW YORK TITLE 10 DEPARTMENT OF HEATH. PROPANE TANK EL. 62.5' GRADE O.O' :t TO GRADE-WITH CAST IRON :` iv I CHAPTER 11.PART 15.5TANDARD5 FOR INDIVIDUAL ONSITE USE; �•�`� � FRAME AND COVER-IF MIX.R ?': '� - WATER SUPPLY AND INDIVIDUAL ON51TE WASTEWATER EXISTING GP TO I -HYDRO-ACTION SET-NfiO ONSITE WASTEWATER EL. 61S' DARK BROWN LOAM OL y PAVED AREA TREATMENT 5Y5TEM5.APPENDIX 15-A 0 x BE ABANDO1�lED TREATMENT PLANT,UNIT INCLUDES: I' BELOW GRADE SITE LOCATION w : 24' ' •S.CD.H5.STANDARDS FOR APPROVAL OF PLANS AND -41 (02--1 • MODEL AN600 6RAVITY SYSTEM Q m CON5n;WTION FOR 5EHA6E 015P05AL 5Y5TEM5 FOR �/ -� PER 56DH5 REDS. .. PRETREATMENT TANK(PT) 0 51N6LE-FAMILY RE5IDENCES-DATED EXISTING;EXISTINGx ¢O 4 •• AERATION U-IAMBER(AG) 4F ' �► /o WELL 1<0��{ ¢�-tpG EXI5TIRO O.H. SERVICE BE •• OP5-OP/GNTL ON TR(GP)W ALARM BEACON aE EL. 58.5' 15'PIPED I \ -C AUDIBLE HORN ALARM Q OGb REMOTELY,A5 SHOWN) N IA MIN i No SURFACE WATERS WITHIN O \f vy �4� ABANDONED. MOVE TO NEW , I�: BROWN SILT ML 0 �' I�MIN (AS REQUIRED) 2"U/6 ELEG GND FROM DWL6 TO REMOTE GNTL PNL , - >- � f' p• Q e, s UNDERGROUND SERVICE. PIPE, ® 300 FEET OF PROPERTY LINE 'S/ v t(' ti 4 BELOW GRADE 'n HIGH DEw:ATY PoLYETHYLENe Mom) �'{� 2"U/6 EL.EG GND FROM A.G.TO OP5 SIZE, ® ® o ® / I 2"U/6 VENT ONO FROM P.T.TO HOUSE STACK � N ORN INLET TO SD COP? = 104)MIN ry 8 EiEl sD TO SD GODB•t. 15"0 MIN I PROP05ED /SO / �p, � 6FI CONVENIENCE RECEPTACLE NEARBY GNTL PNL ROOF LDR COW=44,MIN ® c=N ® ® � ® � � CONTROL PANEL AND BLOWER: 'O' ` , � i � la ® E_� ® ® � I PROP05ED LEAGHING FIELD ® ® 5EE GONTROL PANEL REQUIREMENTS NOTES, g - 3'MIN. 3'MIN. ,� Q TH15 DW6. FOR MOUNTING DE516N AND �; BROWN FINE SAND 5P pc ® ® ® ram USE: �ll (2) 60 x &D' EFF. OP LEACHING, POOLS 17 BELOW GRADE REQUIREMENTS SEE 'PROPOSED 'FI FRAME ♦ , DETAIL',ON DWG 5P2 •LOCATION FOR 50% EXPAN51ON 5HOWN EL. 45.5' � � A •MAINTAIN SEPARATION 015TANGE5 C, ® ® ® WRAP STRIZFILTER URESFABRIC. EMERGENCY o•'J / •MAINTAIN 5% GRADE 20' BEYOND 5AN.5Y5. NO GROUNDWATER ENCOUNTERED ® EL. 45.5' 0-I- WITH FI OTE FABRIC i ,!",.' // •5EE DETAIL5 ON DWG 5P2 HIGHEST EXPECTED GROUND WATER ® EL. 11.26 �y NsE sEOTEx 351,BY GENERATOR O � _. 10� PROPER) 6' TALL PRIVACY EXISTING �� ro � ,\�� ;� EXIST. 2 STORY FRAME PER WELL MONITOR STATION 555524.1 yc�` ry ry ry z CP '`. FENCE AND GATE. DEMOLISHED DWELLING TO BE PROP05M AREA OF DISTURBANCE: 48 GROUND WATER n ,. , . , z .�`Cv' 29,500t sclft (Ob931 ACRE) -COLLARMATERI� ' ; - LOGATION MAP: f ��' R / \` !} \ PURCHA5ED 501L QUANTITIES: NOT TO SCALE O ° i E_X� ` {� THE 51TE 15 FILL NEUTRAL REGARDING THE SANITARY SYSTEM INSTALLATION - - EXIST. FIR SHED #3 �•y �''C \ , ?tea � PROPOSED INNOVATIVE AND ALTERNATIVE UNDERLYING SAND AND 6RAVEL.STRATA TO BE DEMOLISHED PROP. 5TY 3 NO WELL5 4 5ANITARY s>�DRAWING 5P2 FOR SANITARY ON-SITE WASTEWATER TREATMENT SITE PLAN III (6 BORM) DHEL /1 , \`'~ '/ ? �� 5YSTEM5 WITHIN 150 FT. STRUCTURE/COMPONENT DETAILS �� TO BE DEMOLISHED /' I H/ BA5EME�1T \ \\</19.Mk NO SURFACE WATERS SITE DATA: I.COLLAR DEPTH 15 NOT REQUIRED WHEN RATEABLE MATERIAL EXISTS FOR FULL DEPTH. \N' 2.COLLAR MATERIAL SFIAL L BE GLEAN 6RAVEL ONLY. O 3.ALL DRAINA6E STRUCTURES MUST BE WRAPPED WITH FILTER FABRIC. / 10 2 CAR,6AR. I ,' ``� �`���\ WITHIN 300 FT. �,�' SITUATE AT: �' ,' �\ ,' 8255 BRIDGE LANE 4.FOOTING RIN65 REQUIRED UNDER DRAINAGE STRUCTURES. \ I �^ y' .' RIGHARA SA OWNER: 5.U5E 15'DIA GORRI6U6ATED HIGH DEy51TY POLYETHYLENE MDPE)HEAVY DUTY PIPE FOR CUTGHOGUE, NY INTT32GO4NEGT10N OF ON-SITE STORM WATER L.EALHIN6 POOLS ,/ I ' FIN. FL \ `� i \. TEST ,i A.HOPE PIPE 5Pa',IFICATION(AA5HT0 M-21g4) PROPOSED NEW SEPTIC SYSTEM �, , COUNTY OF SUFFOLK P.O. BOX 123-f FOR POOL HOU5E: -` C____ ____ - \ EL.: 65.1 ,I \ HOLE 2,9 ,' GUTGHOGUE NY, I Ici35 B.INSTALLATION OF HOPE SPECIFICATION(,ASTM D-2321) - --- ---- � / ,Pt'� , TOWN OF 50UTHOLD G.WATER-Tl6HT JOINT TE57M 6 5PEGIFIGATnON(A51M D-3212) 1-1000 6AL 5EPTIG TANK ,/ `~ � � I \. EL.: 625 / D.6,45KET SPECIFICATION(ASTM F-411) I-8' DIA. X 12' ED. LEACHING / 0� / � � ,� � SGTM #: (000-84-I-4b POOL /' b /' / R \� `\ _ �' ZONING D15TRIGT: (A-G), A6RICULTURAL-GON5ERVATION DISTRICT TYPICAL STORM WATER FEMA FLOOD MAP / ZONE: MAP NO. 36103GO144H / ZONE X '/ / FIN. FL.E f \ �� n� '�� O AREA OF SITE: 4.3108 ACRES LEAGHING POOL (5D�I DETAIL ,/ 0 L.: 65 ' SD ` < SITE PLAN BASED ON (TRAFFIC, BEARINCI / % �'� ,/ ; I � i ORIGINAL SURVEY BY: U m NOT TO 5CALE'. ,� 'o,/ O• % , \ / _____ -�� 9 ? i�_ 5MITH JUNO 4 OILL15 ^ m { PROFESSIONAL LAND SURVEYOR F+I PROPQSED --- \ �'� 150' FROM O or �Q¢ �/ \ .yti x25/5WIMMI `- �.�D �0 `-O EXISTING 120 MEDFORD AVENUE www.(dignetnycli.com ; ` •. Not of rwyo%CITY wwvw.ca11811.com 1 ��\ / � C` ,1�OOL &SONG I51 Rff (forotherstates) d s. \ry6 ±• EXISTING WELL TO O ADJACENT WELL i PATGHOGUE, NY I M2 W cv yq 800-272-��80 811 g.0�'��0 �� .4 ,�� I, i R BE ABANDONEDI \ \ ` r GONG. PAD FOR: f AU6U5T 17, 2022 DATUM IN NAVD55 W t'n \� � � c \\ � � I � �)4 Dih x 4' GARBA .. � IN. FL. 60 ED.eD eRA GE BIN i 5ETBAGK5: By law,excavators and contractors working in For safety reasons,hoomeowners are strongly 0 Q �, ,� `� DIAY \ / v the five boroughs of New York City and Nassau encouraged to call as well when planning any Q¢pG / 6 �\ b . O ,i \ ,� I PRINCIPAL BUILDING OR STRUCTURE, MIN. YARDS (FEET): W IY� x and Suffolk Counties on Long Island must type of digging,on their property. �� , , < contact DigNet,1-800-272-4480 or 811,at least Homeowners can(contact us directly at / �' ' I REQUIRED: EXISTING PROPOSED: WLU 48 hours but no more than 10 working days 1-800-272-4480 o)r by calling 811,the �� \ , `` ��� , '/ \` , '' i FRONT = 60.0' 43.5' 63.5' [---'I X Z IL (excluding weekends and legal holidays)prior national call before:you dig number.For / , ♦ , \ ,� I , to beginning any mechanized digging or excavation work completed on personal SIDE = 20.0 / 45.0( SOLI( 45.0/ O excavation work to ensure underground lines property,it is the contracto,'s U!(,/' ; ;, ; EXIST. FR 5HED #1 `\ �� ; REAR = 75.0' e75.0' <75.0' are marked.Excavators and contractors can responsibility--NOT'the homeowner's-to HEIGHT= 35\ `- TO BE DEMOLISHED ' I / 2.5 STORY 2 STORY 2 STORY (28-O„) W O US 1 also submit locate requests online,through contact DigNet.Hawing utility lines marked W � � / \ \ � IT IC.If you do not currently use ITIC,please prior to digging is free of charge. fi `y�"• POOL FENCE 1 x l ' n LU ca111-800-524-7603 for more information. 0 � / \ ' :J ; PROP05ED _ TO CODE Abandonment of existing sanitary system must be in confornamce with department requirements.Submit \� ,� 61'9 AGCE55ORY BUILDING OR 5TRUGTURE, MIN. YARDS (FEET): ' `p' ;/ 1-1.5'x20' POOL , -' completed form WWM 080 as proof. \. �' �o� ` REQUIRED: EX15TINO PROP05ED: O CABANA W/ 1 % - •`-� COVERED PORCH i __ \ i SIDE = 25.0' S2.5' Ilx fi? / (SLAB ON GRADE) 1 ' \. i 1\ 102.E 0 REAR = 25.0' 2-ll.Ci' >25' n / 1 0)8'VIA,x b'ED.W ` � \ <' APPROVED N ACCORDANCE �Ir ITHI BOARD r / I/A OWTS UNIT SIZING: --I ENGINEER'S CERTIFICATION REQUIRED E V I E�� E T E M I N IA i_I o 1� A T E D 11/6/2 0 24 � SLD.H.5.DIVISION OF ENVIRONMENTAL QUALITY,STANDARDS FOR APPROVAL OF PLAN5 AND W � O RISo•O I CONSTRUCTION FOR SEWACEE DISPOSAL SYSTEM FOR 51NaE-FAMILY RESIDENCES PROP05ED \ I FOR INSTTALLATTION A D CONSTRUCTION UCTION / NEW WELL \ rj, I / DATED: DMINI"R A 2011 ` I OF Subsurface Sewage Disposal System , / �\ TABLE 3: MINIMUM I/A ON-SITE WASTEWATER TREATMENT CAPACITIES ARCHITECT: b BEDROOM DWELLING: n? 6/11/2025 /'/if ��\ MINIMUM TANK CAPACITY=bbO 6ALLON5 ED ARCM/ 61 �4j `\ ; FOR FINAL APPROVAL. USE FORM WWM-�73. RevisedPlan Approved I/A OWTS UNIT LOAD CALCULATION: ��` \ �-A. R >x ` PROP05M SANITARY VS16N FLOW: 660 6PD 10 AN600 lA 5Y5TEM: 1 1/8/2027 /' ; `,\ •• 6 BEDROOMS® 110 6PD/BEDROOM=660 6PD \ I - AN600 ETU Expires � I � � •USE N HYDRO ACTION WA5TE WATER TREATMENT PLANT I - D15T. POOL ,/ I `� •• USE MODEL.NO.AN600,6RAVITY SYSTEM Q0 \ POO QUI x 8' DEEP LEAGHING POOL `� as TOTAL TREATMENT GAPAGITY: b60 ISM • ,� MIN. GROUND WATER /� i STORM DRAINAGE \\\ ;: TIN6OG 18g5 6PD s �30826 0 Uj�C' \` / (6 BEDROOM) *And Pool House* /' I CALCULATION ' Q. SETBACKS PER LOCAL TOWN ZONING /' '1 150' FROM VOLUME = AREA x RAINFALL x COEFFICIENT �� so LIQUID SURFACE AREA: 5l SQFT. ,T •• SEE DETAIL FOR INFORMATION DW6 5P2 FOF NEw * , T a %c . / " - ' •• d�'�t�f IinL'S Etlll.�t�"'! ,sCt£?Pr ��_tF,v. 1 RAINFALL = 2.0 - O.IbI MAINTAIN REQUIRED SEPARATION DISTANCES,DW6 5PI coEFFIUENr OF: SANITARY LEACHING POOL SIZING: \ / - / 1EX15TINO DANIEL A. BUTLER, R.A. •\, i/ SttSOI Caen ' Q'2t. t3f Fd !t Sf*fi Cos. ADJACENT WELL •PERVIOUS GRAVEL DRIVE/PRK6 = 1.0 LINE / SYMBOL LAC END , C2II (C31)�52-575i4, 4S hours in 1 •ROOF AREA = 1.0 PER 5.G.D.H5.DIVISION OF ENVIRONMENTAL QUALITY,STANDARDS FOR APPROVAL of S.Y. W S.Y. 1 AREA OF: PLANS AND CONSTRUCTION FOR 5EWA6E DISPOSAL SYSTEM FOR 51N6LE-FAMILY PROPERTY LINE ; \ 5ETBA K DWELLING SETBAG 2dv nce, to schedur:? impect€on(s). tl •ROOFED OVER AREA AND IMPERVIOUS STRUCTURES RESIDENCES i •SEMI PERVIOU5 STRUCTURES DATED: DECEMBER 2q,201`1 PRIMARY 5ETBAGK --•--•--'--•--•- �/ \ .' SEPARATION 0151Y NGE REQUIREMENT5 .PERVIOUS 6RAVEL Q FOR 5TORMWATER\LEAGHING 5TRUGTURE5 •DRIVE/PARKING AREAS REQUIREMENT PER TABLE 4: O < ACCE55ORY 5ETBAGK -•• - - - - - �" \`\ I AND PIPING: MIN.LEACHING 5Y5.FOR A b BEDROOM RESIDENTIAL PROJECT CQ Q ` MINIMUM L-EACHIN6 SYSTEM(400 5Q FT 5105 ALL AREA)EXISTING TO BE ............................................ �i \ I I / HORIZONTAL5FP RAIN 15TANGES TRIBUTARY I - < REMOVED/RELOGATED , > < ETU MAIN HOUSE ROOF RUNOFF: MIN.5C'AS EXPANDED 5Y5.(600 5Q Ff.SIDEWALL AREA) }- , \ I I FOR STORM DRAINAGE LEA HIN6 POOLS: Q ,' ` �/ PROPERTY LINE = IO'MINIMUM' 4,144 50.FT.X 0,161 X IA = 02D GU.FT. SANITARY LEACHING POOL DESIGN: O PROP05ED �' \. - -�L- / / 13UILDIN65 WITH CELLAR= 10'kNIMUM STORAGE VOLUME REQUIRED = 02D CU.FT. 0 BLD6. /ADDITION 0�= v �'/ \ _ 2�-, 8 /N BUILDINGS ON SLAB= 10'MINIMUM USE: , TABLE 4 - MIMIMUM LEAGHING 5Y5TEM DE-516N FOR A 6 BEDROOM � U. Q \ 3-a m x 6.o H.(6.o LIQ.DEPTFu RESIDENTIAL PRO.EGT WATER SERVICE LINE/LATERALS/MAINS= 10 MINIMUM LU U) O /�- D.P.��\` > / UNDER6ROUND UTILITE5=5'MINIMUM. STORAGE VOLUME PROVIDED = 160.32 CU.FT. MINIMUM LEAGHIN6 5Y5TEM REQUIREMENT = 400 5Q.FT. 51DEWALL AREA p� 0 z n �" z 7- HATER O -.«- . \. E.P.I I `L.P.1 'MIN ,/' SANITARY LEAGHIN6 POOLS= 20'Mlfylj•1UM TRIBUTARY II- 400 5Q.FT LEAGHIN6 AREA/25.0' 5Q.FTJVERT FT = 16.0 VERT FT REQ'D' Z < = I X \ \_ L �_� PUMP STATION=5 MINIMUM 1J�E: O Uj � Uj 8, / 0 ` DRIVEWAY.PARKING AND MANEUVERIN6 AREA RUNOFF: ELECTRICAL ---t--= ` \ 1 L,P•1 QQ 6 6REA5E TRAP= 5 MINIMUM `� 3,851 5Q.FT.X 0.161 X 1.0 = 643.12 GU.FT. (2) 8'P x V EFF. DEPTH LEAGHING POOL Q }- ` / � 3 ,/ ♦n� +� MANHOLE= T MINIMUM I U Z W LL \ �_� v _ , STORAGE VOLUME REQUIRED = 643.12 GU.FT. : _ p / /00 jPRIVATE WELLS- 50 MINIMUM � MIN. LEAGHING AREA REQ'D - 400 SQ.FT. OF SIDEWALL LEAGHING AREA � N (� < GAS -�- A ' ` - f- 'C� l� RETAINING WALL5 = 10'MINIMUM � 510E WALL LEAGHING AREA PROVIDED = 400 5.F w Uj x (o1.3 \ �'�p•�� FUEL 5TORA6E TANKS(BELOW 6ROUND) = 20'MINIM 2-8 O X 8.O'H.(8.0 LIQ.DEPTH) LOCATION FOR EXPANSION POOL HA5 BEEN PROVIDED Q -„ 5TORA6E VOLUME PROVIDED =615M CUPT. 5ANITARY 5EWER TYPICAL PLOT LAYOUT �� lam, �p N1� '^� �/ Iv O NO SCALE /'S� �'�/ 'C !�N HORIZONTAL SEPARATION DISTANCES FOR 7 (gljYq�'III_ 5GOPE OF Y `ORK: � HMO V_ M M \ ' /C9 4 STORM DRAINAGE NON-LEACHING STRJGTURE5: Z -I FENCE Li �Q @ ��O¢ POOL Pool HOUSE AREA RUNOFF` I. DEMOLISH EX15TINO 25TORY FRAMED DWELLING, EX15TINO FRAMED } 1n 'J #Q' WATER SERVICE LINES/LATERALS/MAINS= 5'MINIMUM `�UNDERGROUND UTILITIE5=5'MINIMUM N i- O OVERHEAD ELECTRIC -^ -• -� -• - {/ \ ,/ ' to co' POOL 800�.Fr?C 4 AV6.DEPTH = 3200 Gl1.FT. ACCESSORY STRUCTURES, AND RELATED UTILITIES AND SANITARY. 3,200 X(10%) = 32 .FT. O (v VERTICAL SEPARATION DISTANCES FOR 2. CONSTRUCT NEW 2 STORY FRAMED DWELLING WITH ATTACHED � � 'J 'J � O I STORAGE VOLUME REWIRED 320 GU.FT. TEST HOLE � .: .J L. / 0 STORM DRAINAGE LINES: ,_,_____ __ GARAGE, PORCHES, POOL AND POOL HOUSE AND RELATED (UTILITIES. � � Cn \. f ¢�(/� WATER SERVICE LINES= IS'MINIMUM m .gyp 4 .� POOL PATIO: _-_ 3. POOL HOU5E REVISED TO INCLUDE � BATH. MINIMUM 5Y5TEM U- (V SANITARY WASTE LINE5 = 0'MINIMUM 3,600 5Q.FT.X 0.161 X ILO = 601.2 CUPT. O MONUMENT ® iP / �GDETAILS. d \ � t� STORAGE VOLUME REQUIRED = 601.2 GU.FT. 5EPARATION 015TANGE REQ'MT5 FOR SEPARATION 1215TANGE REQ'MT5 FOR Pool HOUSE. t'() O 5ANITARY 5EPTIG TANKS: 5ANITARY LEAGHING STRUCTURES: 400 50.FT.X 0.167 X ID =bb.&CUPT. � Z) Z 5, t e r S MIN.\ ,/ HORIZONTAL SEPARATION 0I5TANCE5: MINIMUM HORIZONTAL SEPARATION DISTANCES: 5TORA6E VOLUME REQUIRED = 66.8 CU.FT. LLI �' m e r `_'0 ��/ A.BUILDING WCELLAR= 10'-0' A.BUILDING W/CELLAR = 10'-0' SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES I < " B.BUILDING ON SLAB ="10'-0" SUB TOTAL FOR POOL POOL PATIO AND POOL HOUSE: PERMIT FOR APPROVAL OF CONSTRUCTION FORA (V O Q " G.WATER LINES = 10-0 STORAGE VOLUME REQUIRED = g88.0 CU.FT. 0J 05 B.BUILDING ON 5LAB = 5-0 G.WATER LINES = 10-0 � 1(�� (�o N\ D.SURFACE WATER(WETLAND5) =15'-O" D.SURFACE WATER(HETLAND5) = 100'-0" SINGLE FAMILY RESIDENCE E A1\!D tL/ UIJ E F.PUBLIC WELL = 200'-0" F.PUBLIC WELL = 200-0 USE: Li 9 6.PRIVATE WELL = 100'-0" 6.PRIVATE WELL = I50'-0" 3 -&V X b.o'H.(6.0'LIQ.DEPTH) Pool House O \ H.RET.WALL(WTRPROOF) = 10'-0" H.RET.WALL(WTRPROFF) = 10'-0" STORAGE VOLUME PROVIDED = 10131b CU.FT. J.U/6 FUEL TANKS = 20'-0" J.U/6 FUEL TANKS = 20'-0" z J U N 1 2 2025 9 0 (n K.U/6 UTILITIES= 5'-0" K.U16 UTILITIE5 = 5'-0' STORAGE VOL.REQUIRED: 2,323.12 CU.FT. DATE- 11/8/2024 H.S. REF. No. R-24-0943 u- V� L.STORM DRAINS= 20'-0' L.STORM DRAINS = 20'-0" 5TORA6E VOL.PROVIDED: 2,444IA2 CU.FT. f LLJ T I / 00 " M.CATCH BASINS,NON-LEACHING= 5'-0" APPROVED ' ix , - M.CATCH BASINS = 5-0 w '� -O' NOTE TO 11`15TALLM (NON-LEAGHING) P.N.SPROP LINES' O'-0" ALL DRAINAGE STRUCTURES SHALL BE PLACED IN - TOTAL MAXIMUM BEDROOMS 6 + 0 � ~-1.ur �''' •`t V� \ - �� N.5AN.L.P. =B-0 I ==--- _ - - � � Q.T.O.SLOPE - 25'-0" ACCEPTABLE LEAGHING SOILS(SP OR SHU,IN THE EVENT _ _ � P.PROP.LINES = 5-0 EXPIRES THREE YEARS FROM DATE O APPROVAL Q.T.O.SLOPE = 25'-0" R.BLUFF = 65'-O" POOR LEAGHING MATERIAL 15 ENCOUNTERED,EXCAVATION 15 ° (� 30 15 0 30 60 CIO 120 150 p R.BLUFF = 65'-0" 5.5EPTIG TANK = 8'-0" TO BE CONTINUED V BELOW BOTTOM OF 5TRUGTURE AND 3' 61.1 �� �G BEYOND SIDEWALL5 FOR A Y COLLAR AND 6'5TRATA sGDHS APPROVAL AREA: (1 OF 2) C�RAPHIG SCALE I" = 30_0 \ x l'� BELOW STRUCTURE. SURROUND AND BED WITH SUITABLE MATERIAL 5P OR 5 S.C.D.H.S. SET it i SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICS, (2)2x8 x(LENGTH TO SUIT)AGO _ __ PROP05E1D DWELLING HORIZONTAL CRO55 MEMBERS(TYP) o MAINTAIN 5%6RADE: P EAPROVD SAFETY LID OF DEVICEE SHALL BE PROVIDED. A SECONDARY (CELLAR) A MAXIMUM 5%514ALL BE MAINTAINED FOUR A MINIMUM OF 20'HORIZONTALLY UST FL.EL.65.1' (b BEDROOM) FROM THE NEAREST EDGE OF THE LEAGHIING POOLS BEFORE TAPERINs OFF R E F E REl`�1 C E I`;I U I`'Idi R-24-0943 B E R: PROVIDE GONERS: • I/A OWTS • � TO PREVENT 5EEPA6E OF THE LEACHATE THROUGH THE TOE OR EDGE OF THE SLOPE(EQUA,TE-5 TO MAXIMUM DROP OF 12'OVER 20'HORIZONTAL) WHEN REQUIRED TO BE 5ET AT FINISHED 6RADE USE: • ELECTRICAL .S E E DRAINING # 1 4 F 2 FOR SPECIAL CONDITIONS •THERMOPLASTIC COVERS-LOCKING,WATERTIGHT, USE(4)VIP 6ALV GNTL PNL W PROVIDE COVERS: INSECT-PROOF,FLAT,SKID PROOF,BE APPROVED FOR 5EWA6E " LA6 BOLT W/6ALV. • 12'w x 14'n • WHEN NOT REQUIRED TO BE 56ET AT FINISHED GRADE USE: REVIEWER'S INITIALS: AC USE 4 HAVE UV PROTEfGTION GRADE a DWELLING 2 m PVG WASHER a HEAD •PRE`.GAST REINFORCED GONaGRETE COVER(OR EQUAL) = EL.63.6' VENT PIPE (TYP a EA.POST) • • CONNECT TO 6RAD)E OVER ETU a b2.8'+/- C 0 HOUSE STACK 4x4x8'L6 AGQ THE MINIMUM COVER 36" MUST 5U PLACED OUTSIDE } GRADE OVER L.P.EL.628'+- TIMBER POST CONTROL PANEL BOX � ni BELOW GRADE ON A SUITABLE PEDESTAL INCASED IN POURED WITHIN VIEW OF THE 5) z O THAT IT SERVES.CONTROL d� z CONCRETE IN 12" I CENTER 5HALL BE ¢ DIAMETER SONOTUBE. u? z Q (TYPICAL) MOUNTED 35'ABV FINI5HED m _ /� GRADE(MIN)OR ABOVE •Q T.O.SLAB: EL.blb' / PROPOSED BEE,WHICHEVER IS HIGHER. I B.O.SLAB: EL.61.1' _ g 1H' FRAME DETAIL (STRUCTURE FOR I/A OWT5 CONTROL PANEL MOUNTING) DISTRIBUTION POOL __ - I I HOUSE INVERT TO INN®DWELLING= ELbO.I' SCALE: NONE ] T.O.5LA113:EL.602' o DP _ c_Illl PRE-TREATMENT TANK (PT) ---------- 5ql ---------- - - U5E: 4"(P 5DR 35 PIPE, m N "-B.O.SLAEB: EL II p III I i l I.E.a PT MIN. SLOPE =,V4' /LINEAR FOOT GRADE INN.a D.P. INV.a AL. DWELLING: 20.0- RUN X " = 0.25- EL BD. M. I I I I A.C. I I I °EL.5gb7 \ j a \j\j\j a I.E._EL.5q2' DISTRIBUTION POOL (DP) =EL.545 =EL.5g57 I / NATIVE TO LEAGHING POOL (LP). EL 8'b:® AERATION GHAM13ER (AG) TO II II ��AII'1[®I� I RATEABLE L.P U5E: 4"(U 50R 35 PIPE, �_ D15TRIBUTION POOL (DP) II �bS MIN.SLOPE _ �" /LINEAR FOOT O'1 '-, U5E: 4"c0 5DR 35 PIPE, II SOIL I FAGHINt1G POOL(5) P.T. JJ JJ (I OF 2) 8.0' RUN X �" = 0.083' (0.10) EL 5q3 � MIN. SLOPE _ �" /LINEAR FOOT II I! �T�T �/ 8.0' RUN X �" = 0.083' (0.10) II TANK CL ry II I II PUMP/GOMPRE55ER POWER CIRCUIT I I° d I I° a LD 'S �J III GBI MI BLK BD.CHAMBER a EL.54412' B.O.TANK a EL.54.g2' LI LI 0-- -{� SPI SPRAY PUMP RATIN65: I I I I SANITARY SECTION - MAIN HOUSE NOT TO SCALE N N WHT N MHO 3/4HP a 115V 15.0 FLA °. °. u L I L GB2 M2 65R 6 LOOPS I I r--O m j 4 4 4 4 BLIK RPI REGIRG PROVIDE 20 AMP BREAKER IN ul$> r PUMP PUMP RATIN65: O O o o MAIN ELECTRICAL PANEL IN - N MOTOR 3/4HP 0 115V 15D FLA. 3'-O"RATEABLE B.O.POOL a EL.512' 3'-0"RATEABLE e PROPOSED BUILDING FOR PROPOSED I/A OWT5 I I 501L COLLAR 6 DIAAMETER 501L COLLAR 663 M3 Z� I �•�•�•y _ � NEW 20 AMP,I POLE BREAKER DEDICATED FROM UTILITY AK-080917-1 =� z � BILK TO HYDRO-ACTION CONTROL PANEL PROVIDER (Y� r MPI MIXER n, © 14x 12 PUMP PUMP RATIN65: 120 VOLT,I�SERVICE TO HYDRO-ACTION INGOMIN6 5DV. m 0 ® ® ® ® °ig O INSIDE LID VIEW T N MOTOR 3/4HP® 115V 15.0 FLA CONTROL PANEL (DETERMINED NOTE: ENCLOSURE HINGE TO THE RIGHT (2#6,#6 IN I"PVC,PIPE) BY OTHER5) .. ON ON aN ON o �® II-Q r za zo z" D F ! I ..Q o' 10' ,,,+ ® GI AERATOR HYDRO-ACTION I/A HYDRO-ACTION WTS MAIN BUILDING y G ^ N M OFF OFF OFF OFF DFF COMP COMP.RATINGS: ELECTRICAL CIRCUIT BREAKER METER l l)^ ^ ^ ^ ^ T MOTOR 1/4HP a 115V 5.4 FLA. CONTROL PANEL PANEL •� �L � C65 �{96 IL16'>1Dai6NB� NO GROUNDHATIER ENCOUNTERED ® EL. 45.5' ® ® ® ® ® N 12"w x 14"h NOTE: ALL MOTORS MUST HAVE w n X � � � � � INTERNAL OVERLOAD PROTECTION. l HIGHEST EXPECTED GROUND WA'LTER � EL. 11.26' � ham•--�I PER HELL MONI"FOR STATION 55:3324.1 Q v , � Q v„ u : Q ® � ELECTRICAL NOTES: W <I. BURIED ELEGTRIGAL POWER GONI)UIT5 5HALL EXiND R •'LAPELS ON OUTSIDE OF LID BLU I LRI-QI RED/H�f H BE A MINIMUM OF 24 INGHE5 BELOW GRADE. GROUND ROD X Z " 0 ® � P1 N P1 N P1 N C1 N 1 2 3 4 5 6 � MI 2.ALL ELECTRICAL WORK TO BE PERFORMED IN uz M(2 M9 � � ®- MQDI4LIL�Ac 49 f�ug AGGORDANGE WITH NEG. _ FIN15HD 6RADE �' �' Q =s��rau�a=a '---------a==� '�aa=�� =__ ® BLU I LRI-Q2 PINKMBi CQ < US ® � Y M2 ELECTRICAL ONE-LINE DIAGRAMCONCRETE I� o o < a < a PINKMH ? 0 0 0 0 0 o m = " m - w o 0 0 92 0 2�-'I `V ��® m 3 Q Q BLU 1 LRI Q3 A REGIRG RUNNING SOS E NONE iL . WHT 0 SUITABLE COVER SPRAY q{}p � y � U � � a � � � � "' STOPPER OR CONCRETE ® / _ ® °ate a a o a w �a 3 3 LE--� L/ (� CHIMNEY F2O" NMI N CI N t 2 3 4 5 s 4 . R�(de Abi�� ax®PUMP) QG�PU(6[I R a XEND PLUGTO GRADEI °UM� M� °�P) NIi NOTE: ADDITIONAL CLEAN OUT SHALL BLU LRI W"T NO HOUSE I BE PROVIDED TRAP 5HAU BE PROVIDEDE �I=-�- = J_ I 67, CONNECTION DIAGRAM LRI-04 MNAPPRDYE s f REQUIRED TORQUE FOR TERMINAL BLOCK SCREWS IS 16 in BLU REV 16 PLC INPUT SEWER PIPE PER IRG 201'5,P3201.4 PIPE PITCHY uJ 'I BLU A5-1 PINK - -- - - -- - 30°ELBOW ^ t-. I YF PER 1-0" \� 1 Q _ __ _ TYPICAL NOTE-5: � -�-I _ r,�,,, CONTROL PANEL REQUIREMENTS: _ __ I.FOR GLEANOWT(5)LOCATED IN \ _ - L ON A SUITABLE PEDESTAL WITHIN VIEW OF THE ALARM TRAFFIC AREAS, FRAME AND ARGHiITE w - O _ - - O o ° I.THE CONTROL PANEL BOX MUST BE PLACED OUTSIDE BLU 5 6 RED �__ AUD. EXTERIOR TRAFFIC ARFJAS,PROVIDE WITH ND BLOHER GLEANOUT CT- 3' COVER COMINLLAR 3�AR ' 5HALL BE MOUNTED SERVES.SYSTEM T14AT IT ABYFINISHED CNTR A6RADE(M HWA ORG BRN N.TS. 2. WITH BUILDING OR ABOVE BFIE HIGHER SEE 'H'FLUS RAME DETAI�L�ON DWG 5P2.WHICHEVER 1ST QED AR T BLU EXTENSIONS/G ONNEGTION5. 5EPTIC TANK QX45TRUCTION CRITERIA: 2.EXTERIOR PANEL(NEMA 4X SPECIFICATIONS) , ALARM b0•W E Q�\�✓ r�F�O� I.FOR AREAS ON SAND AND GRAVEL,THE eRoy e�� RF PLACEMENT ENABLES THE SYSTEM TO BE SERVICED O QV DESIGN OF THE LEACHING POOL 5HALL BE F AT ANY TIME,ELIMINATING THE NEED TO ACCESS THE LIGHT BASED UPON A MAXIMUM LEACHING RATE OF 5 3 INSIDE OF THE BUILDING. RED BLK WHIT 1.5 6ALLON5 OF 5EWA6E PER DAY PER S.F. m 3.THE CONDUIT MUST HAVE APPROPRIATE SEALS TO E '� OF 510EWALL AREA. PREVENT 6A5E5 AND MOISTURE FROM REACHING THE , 2.LEACHING POOLS ARE TO BE CONSTRUCTED I1.4 CONTROL PANEL OR.UNCTION BOXES. 3'MIN TO E L b'-0. OF PRECAST REINFORO D CONCRETE(OR o�� 0 4.5Y5TEM SHALL BE EQUIPPED WITH A FUNCTIONING ENABLE S '30826KATER RECORDED m EQUAL)LEACHING STRUCTURES,50LID 1 WARNING SYSTEM WHICH WILL ACTIVATE AUDIBLE AND o¢ DOMES t/OR SLABS. i � I VISUAL ALARMS THAT CAN BE READILY SEEN AND BLU I 2 Ii PLC INPUT �TFOF NOV SOP F=~ 3.LEAGHIN6 POOLS SHALL BE A MINIMUM OF 8' / ;il'li'rif iiiia;-; HEARD BY THE OGGUPANT5 OF THE BUILDING SERVED. �- COLLAR DEPTH �¢ IN OUTSIDE DIAMETER ' ('BACKFILL TO BE GLEAN 4.ACCESS OPENIN66 WITH A MIN.VIA.OF 20" 729 AL. /i A �I. ° oRc uuG vU 5PPREI KITH MEANS OF CONNEURIZED MUST BE ECTIIN5 A PORTABLE CONTROL OVERRIDE DANIEL A. BUTLER, R.A. SAND AND 6RAVEL) ¢ SHALL BE PROVIDED FOR EACH POOL. 6EJERATOR TO OPERATE THE SYSTEM DURING A 5.ALL COVERS,WHEN NOT REQUIRED TO BE PRE_TREAT r% /ATU TANK NITROGEN BLU 3 4 G5R 12 PLC. INPUT >1vs BROU6HT TO 6RAVE,SHALL BE OF °//� EDUC ON TANK N ° POWER OUTA6E. BLU 1.ALL APPLICABLE RECOMMENDATIONS PROVIDED BY THE MANUFACTURER ;fl PRECAST REINFORCED CONCRETE(OR I4 PLC INPUT SHALL BE IMPLEMENTED. CQ CQ ELEVATION EPERMIIT�OVER 3'm ARE NOT � ,,� %� � 1° 2.THE SEPTEG TANK 54ALL BE INSTALLED AT LEVEL IN ALL DIRECTIONS Q < < TAN PLC INPUT (NTH A MAX.TOLERANCE OF tl/4')ON A MINIMUM 3"THICK BD OF b. ALL CAST IRON COVERS SHALL BE SET AT d) -- TIME P05E 17 PROPERLY LEVEED AND COMPACTED SAND(FREE FROM ROCKS)OR PEA 0 TYPICAL FIN.GRADE,BE LoucIN6,WATERTIGHT, *' BLU GRAVEL. _ IN5EGT-PROOF t APPROVED FOR 5EWA6E "� \f DEMAND W �`� ° 3.ALL OUTLETS FROM THE SEPTIC TANK SHALL BE PROVIDED WITH DROP'T' . . al OR EQUIVALENT BAFFLE APPROVED BY THE DEPARTMENT EXTENDING INTO SANITARY LEACHING POOL (LP) USE �� `F� �� SPRAY 18 PLC INPUT THE LIQUID ON THIRD OF THE LIQUID DEPTH. 04 NOT TO SCALE �, ELECTRICAL SCHEMATIC DIAGRAM BLOW DEFLECTION ��ARE RECOMMENDED FOR INSTALLATIONS O Q WI BI WI 5.TANKS SHALL BE PROVIDED WITH 51NSLE OUTLET. A DISTRIBUTION BOX 15 � J J J 1(� 0 CQ W ° NOTES: REQUIRED FOR ALL SYSTEMS WITH MULTIPLE LEACHING POOLS UNLESS AN u } ` o-� - ° FLOAT SWITCH TO BE RATED 2 AMP AT 120V MINIMUM. v Z i Z Z MAIN PANEL DISCONNECT MUST BE PROVIDED BY INSTALLER. ALTERNATE DE516N I5 APPROVED BY THE DEPARTMENT. Z < T z z O NOTES: 6.THE OUTLET SHALL BE LOCATED AT THE MAXIMUM P0551BLE FLOW PATH F-1 PROWIDE GOVER5: ® DASHED LINES INDICATED ITEMS NOT CONTAIN IN THE PANEL. c1 I. PIPE JOINTS TO BE SEALED HV REQUIRED TORQUE FOR TERMINAL BLOCK SCREWS 15 I6 IN-LBS. FROM THE INLET. Q < WHENI REQUIRED TO BE SET AT FINISHED GRADE PLC,GNTRL PNL W/HPI20 COMPRESSOR AND 1.THE TOP OF THE SEPTIC TANK SHALL NOT BE LOCATED GREATER THAN � � � IY IL A5PHALTIG MATERIAL OR EQUAL. FI RING MUST BE A MINIMUM WIRE Lu Z 2.U5E ENDGAP TYPE LEVELING U5E: BLOWER TO BE INSTALLED REMOTELY POWER LINE AND M15G.CONNECTIONS FOUR FEET OR LE55 THAN ONE FOOT BELOW FINAL GRADE. FOR SEPTIC lD ( Q < HEAVY DUTY,WATERTIGHT, IN5EGT-PROOF (5EE 51TE PLAN FOR PROP.LOGJ TO BE MODIFIED A5 REQUIRED TO TANKS WITH DOMES,THE TOP OF THE DOME SHALL NOT BE LOCATED w Lu W C) DEVIGE5(TYPIGAU ACCOMMODATE REMOTE LOCATION OF POOL HOUSE GREATER THAN TWO FEET OR LESS THAN ONE FOOT BELOW FINAL GRAVE. ( Q ADJU75TABLE AND LOCKING CAST IRON FRAME d Q O OPS CONTROL CENTER A5 SHOWN ON (SLAB ON � MAINTAIN 5%MAX.SLOPE FROM ED6E OF SANITARY f'- M O _ COVER(GAMPBELL 1182 C OR APPROVED EQUA q.A 10'min.DISTANCE BETWEEN SEPTIC TANK AND HOUSE SHALL BE u-1 SITE PLAN FINISHED GRADE SYSTEM oUT WIN EACH DIRECTION \x \/ //\�, - ___ -_- - ---#- FI AFL. r+rasl�eRAOE MAINTAINED. w � � Z\ � O d- C.1.COVER G.I.cQVLR (� �_ 1(� V O N 2"PVC VENT LINE(TIE 9P/'6+5' 'MAX L EACHIN6 POOL - INSTALLATION REQ"MTS BAFFLE REQUIRED IF --. - a INTO BLD6 VENT STACK) 4•H01 ' :b ' 20- INTO LL l) N INLET PITCH EXCEEDS - -- -, - - - F �- MI CA.PIPING I.MINIMUM LEACHING SYSTEM FOR A I TO 4 BEDROOM HOUSE 15 300 sq ft SIDEWALL (`{) Y" PER FOOT ° ° Icy 6 N V ��„�,'/UK "n AREA.I POOLS;B'DIA. 12'DEEP m - F�- ��- 4'GJ.PfiIN6 10'•1.75'•OJ04'MN SIAPE 4"(P 5[DR 35 PIPE, a INSTALLATION 1 � II --- ► PrrcNI~'/UKf1r. IE=623' r M !L N B 60•I5-OnV FIN �.� II II •625' rTff IE•bib' T RECORDED 6ROUNDWATER LEVEL AT THE PROPOSED SYSTEM'S LOCATION t AT LEAST 2' a MIN.56LOPE =y8"/LIN FT REQUIREMENTS: Ii � IP=bib' pal ALL OUTLET PIPE5 5ET® 5AME x I. Q FOR SHALLOW ALTERNATIVE SYSTEMS APPROVED BY THE DEPARTMENT. I.THE I/A OWT5 TANK SHALL I A.C. l I 3.LEACHING POOLS SHALL BE PIPED DIRECTLY FROM THE SEPTIC TANK OR INVERT ELEVATION � DISTRIBUTION Box � Z � BE INSTALLED AT LEVEL IN ��'](�®j� I I � Z ALL DIRECTON5(WITH A 4 N 4.LEACHIN6 POOL COVERS SHALL BE AT LEAST I MIN.BELOW GRAVE,BUT NOT MORE 'Cr (C�C� ]E� 1000 GAL SEPTIC TANK O F' z z `fi MAXIMUM TOLERANCE IN T D. o N POOLI SLAB OR FOR TO WITHIN 4'OF GRADE USED TO BRING THE TOP OF THE (V V O ANY DIRECTION OF+/ONE N QUARTER INC ON A 1T2 F T' t(� - 5.THE MAX.PERMISSIBLE DEPTH OF A PRECAST GONG.L.P.IS 25'BELOW 6RADE. (K -7 Q ry a 5.L AC I t MYO T'EXCEED 2 H HEIGHT•OR REINFORCED IF NEC PRECAST IONCRETE,S I5�L INLET(5,1 _ MINIMUM 3-INGII THICK BED l�][�ET�TI�IT I I II II `n • • , 4"� 5DR 35 PIPE, ouTIQET(5) OF PRAND OPERLY LEVELED T� I ii PROP05ED SEPTIC SYSTEM DETAIL •• INSTALLED AT 6RADE. MIN.SLOPE =ye"/LIN FT °. ° <si a (FREE FROM ROCKS)OR I PROPOSED POOL HOUSE :•4, b.THE BOTTOM t 51DEWALL AREA OF THE L.P.SHALL BE FREE OF DEBRIS BEFORE z BAGKFILLING. THE EFFECTIVE LEACHING AREA OF A L.P.(BELOW THE INLET PIPE)SHALL ALL INLET5 PIPE5 5ET-� ° d PEA GRAVEL• II II NOT TO SCALE 3�� r S.O' ' BE INSTALLED ENTIRELY IN SAND t 6RAVEL. SAME INVERT ELEVATf011 _ . I NO GROUNDWATER ENCOUNTERED @ EL. 455' col EAR •'. 7.ALL COVERS,WHEN NOT REQUIRED To BE BROU6IfT To GRADE,SHALL BE OF PRECAST ry .. , B3AGKFILL SAND OR . . '. _ '. . '.'• '. I ;._ HIGHEST EXPECTED GROUND HATER @ EL. 11.26' in REINFORCED CONCRETE(OR EQUAU.Gov>=rx5 OVER 3'VIA.ARE NOT PERMITTED . PEA GRAVEL(I2" MIN)' •'.' • •'.• •'.• •'.' u u 8. ALL CAST IRON COVERS SHALL BE SET AT FIN.6RADE,BE LOCKING,WATERTT6HT, PER WELL MONITOR STATION 553324.1 INSEGT-PROOF t APPROVED FOR SEWAGE USE. 5.0' S5' q.A 10'min.DISTANCE BETWEEN LEACHING POOLS AND WATER LINE 5HA:LL BE � TYP PRE-CAST DISTRIBUTION BOX - MAINTAINED. a • HYDRO-ACTION WASTE WATER TREATMENT PLANT MAINTAIN D. DISTANCE BETWEEN A1' 'EAc"'N6 POOLS AND SEPTIC TANK SHALL BE SPZ NOT TO 5GALE MODEL No. AN600 (GRAVITY SYSTEM) til ki (2 OF 2) S.C.D.H.S. SET 2 A 18' 34' X B 24 5' 38' 183.5' 1 -I W C 34' 57 57' 190.5' U' X 0 D 36' 54.5' 64 W hh�� W* _ U Lr) Z N J WI - O LL LL x o O Z) LL Ln Z O I � U_z xO O O_ J I � X � O I X I1.9'W x .J I 2 LL O LL } I •� z 0 a1\ \ Z Q M � O _ Y � x Ln E M O Z I WELL ! {I} O O N JUN 2 6 20220 II X 178.20 g'T �gTTV�tf t- EWCE 0.2'W 0.6'N 399.99' 1.4'E I BROKEN N 47035'55 W OREGON ROAD ESTATE THE WATER SUPPLY, WELLS, DRYWELLS AND CESS LOCATIONS SHOWN ARE FROM FIELD OBSERVA770N MON. VINEYARDS LLC AND OR DATA OBTAINED FROM OTHERS SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES NAVD88 AREA:187,777.68 SQ.FT. or 4.31 ACRES ELEVA77ON DATUM. APPROVAL OF CONSTRUCTED WORKS FOR UNAUTHORIZED AL7ERA77ON OR ADD17701V TO THIS SURVEY IS A VIOLA77ON OF SEC7701V 7209 OF THE NEW YORK STATE EDUCA77ON LAW. COPIES OF THIS SURVI A SINGLE FAMILY RESIDENCE AND MAP NOT BEARING THE LAND SURVEYORS EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. GUARANTEES INDICATED HEREON SHALL Rl ONLY TO THE PERSON FOR WHOM THE SURVEY 1S PREPARED AND ON HIS BEHALF TO THE 777LE COMPANY, GOVERNMENTAL AGENCY AND LENDING 1NS777U77ON LISTED HEREON, AND TO THE ASSIGNEES OF THE LENDING INS77TV770N, GUARANTEES ARE NOT TRANSFERABLE. Pool House THE OFFSETS OR DIMENSIONS SHOWN HEREON FROM THE PROPERTY LINES TO THE STRUCTURES ARE FOR A SPECRC PURPOSE AND USE THEREFORE THEY ARE NOT INTENDED TO MONUMENT THE PROPERTY LINES OR TO GUIDE THE EREC77ON OF FENCES, ADD177ONAL STRUCTURES OR AND OTHER IMPROVEMENTS EASEMEA AAMD/OR SUBSURFACE STRUCTURES RECORDED OR UNRECORDED ARE NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT THE 77ME OF SURVEY Date 6/24/2026 H.S. Ref. No. R 24-0943 SURVEY OF:DESCRIBED PROPERTY 0F. N CERTIFIED TO: RICHARD SACHS; MAP' OF: The sewage disposal and water supply facilities at this location have been inspected and/or certified by this Department or other agencies and found FILEID: to be satisfactory FOR TOTAL MAXIMUM OF 6+0 BEDROOMS. slnnATED Ar.CUTCHOGUE TOWN oF:SOUTHOLD -p KENNETH M 'WOYCHUK LAND SUFFOLK COUNTY, NEW YORK �,�� SURVEYING, _ s ,.moo c 82 Professional Land Surveying and Design it �G1 i, ., F AS—BUILT 05-07-26 � � � FND. LOC. 04-28-25 P.O. Boa 153 Aquebogue, New York 1193 Office of Wastewater Management nLE #225-01 SCALE:1"=30' DAlE:JAN. 15, 2025 N.Y.S. LISC. N0. 050882 PHONE (631)298-1588 FAX (631) 298-1588 I F -M.# DISTRICT 1000 SECTION 84 BLOCK 1 LOT 4.6 U.P. ' U.P.0 LU EDGE OF PAVEMENT J BRIDGE LANE W w HEDGE W GATE S 45015'35" E STK. 397.00' MON. r1'sX 'E 4'WOOD/WIRE FENCE 7.4'S z � 4'WOOD/WIRE FENCE GATE ui I / LP2 o O LP1 ILL X 4i L11 N ST DP LP1 LP2 I� DP A GATE X aQ �/ 28' 36' 49.5' S0;5' B O I J S.T. X DW 0 i DRAIN �S� O AIR 00 X R PUMP T r \ DW X I 0 m :::•:':':':':::::';'';';' m z m 45.2' c\ WINDOW •:: to X WELL :;.•� I 00 o \GFRAME:- z z DWELLING#8255 cn X 33.5 :•: :•: �l A m (7 DRAIN 1 II a POOL HOUS ������ AREA CALCULATIONS: WINDOW FALL PROTECTION: E DOOR � Q `7 SC POOL HOUSE 350 SF PROVIDE WINDOW FALL PROTECTION AS REQUIRED BY CODE. EGRESS � o DOOR COVERED PORCH 150 SF WINDOW MUST MEET MINIMUM CLEAR OPENING OF 24" HEIGHT, 20" WIDTH, AND a z 5,l SQ,FT, NO, LEVEL DOOR TYPE WIDTH HEIGHT THICKNESS REMARKS OPENING PROTECTION BY WOOD STRUCTURAL PANELS PERSUANT TO o° w z OI IST FLOOR (FIN,) CUSTOM 2'-6" 1'-O' 1 3/4 1609,1,4, SEE FASTENING SCHEDULE ON DETAIL SHEET IN THIS SET, o 0 02 IST FLOOR (FIN.) D 6'-O" 1'-O" PER MANUF, � 03 IST FLOOR (FIN.) El 2'-6" 1'-0" 1 3/4" SEE DETAIL SHEET FOR HIGH WIND CONNECTION REQUIREMENTS ° z w Q z SEE SHEET A-4,0 FOR WINDOW AND DOOR SPECIFICATIONS, u POOL HOUSE WINDOW SCHEDULE WIDTH HEIGHT HEAD � o NO, LEVEL WINDOW TYPE (F,S,) HEIGHT MOD>EL REMARKS � Q OI IST FLOOR (FIN,) DOUBLE HUNG 48-1/4" 64-1/8" 1' - 0" 4121 Q a x ►- 02 IST FLOOR (FIN.) DOUBLE HUNG 48-1/4" 64-1/8" 1' - O" 4121 0 N 03 IST FLOOR (FIN,) DOUBLE HUNG 56-1/8" 64-1/8" 1' - O" 4921 0tu 04 IST FLOOR (FIN.) DOUBLE HUNG 25-5/0" 44-1/8" 1' - O" w I811 N 05 IST FLOOR (FIN,) FIXED 60" 48" 1' - O" CUSTO1"1 w o 06 IST FLOOR (FIN.) FIXED 24" 24" 15' - O" 1818 Ol IST FLOOR (FIN,) IFIXED 24" 24" 15' - O" 1818 d) O. MAX, HEIGHT = 22'-0" MAX, HEIGHT = 22'-0" J 4 u I j - J CONTINUOUS RIDGE VENTING 1 J UPI lL ULI U U 11 LI- _- .L _Ii L. L I Ll u u �� `IrII'I'I.uu a u ASPHALT SHINGLE ROOFING J- LTL' lJ J L J J L LI L L:__L1. .L L L I L f �� MITI�� L u' 12" J J U.U' LI U7 LJJU L— L -LL L _ L- 1 JI - _ u � L\ L u L FASCIA: 1X8 WITH CROWN 1818 9" Al .u u u u_u 'll i L _ -� - - - - ,X a ASPHALT SHINGLE ROOFING u TO MATCH EXISTING 12" -IT, 5" OGEE (SUTTER, BLACK g 5" OGEE GUTTER 2 I' J � u u u. ll Ju BLACK 411 a u, L u u u T,O, PLATE Ili — — — — — 09L — — — 10' - O" `V B4O, HDR. / '4 m A-+ O GIRDERI-F 1, - 9„ — — — — — — — T,O, DOOR/WINDOW r 1' - O" 6" CUSTOM WOOD I ❑ a TURNED 'HISTORIC' O �p COLUMN PROVIDE o= p ! 8"-10" VERTICAL BOARD SIDING m o SIMPSON CONNECTIONS W X AT TOP AND BOTTOM, r p W r TYP, u X Z d BRICK PORCH cv FIN, FL, Q 1O _ O 3: 0 `� • ° • , ° 8° GRADE — — — o N b a ° a • e • GRAD C—� a- ao 0 �STEP TO GRADE PARGED EXPOSED PER CODE CONCRETE FOUNDATION I I m �p P.C. FOUNDATION AND FOOTING - I - - - - - - - -I �4 - - - - - - - -- >� - - - - - - - M F-L - - - - - - - - - - - - - - - - - - - - - - - - - - -- w .. w-1-- — — — — — — — — — — — — — — — — — — — — — — — J — — — — — — — — — — — — — — — — — — — — — — — — — — J w W ~ I -y FOOL HOUSE SIDE (RIGHT) ELEVATION FOOL HOUSE REAR ELEVATION 1/4" = 1'-O" ARCHITECT: 4: os oath MAX, HEIGHT = 22-O — — — — — — — — — — — — — — — — — " — — — — — — — — — — — — — — MAX, HEIGHT = 22'-O" PI AY 1 S 2025 DANIEL A..BUTLER, R.A. CONTINUOUS RIDGE VENTING TOWN CLD HISTORIC PRESERVA71ON 1rI0N COMMISSION i IJ L L L O LJIl LJ J�LJ1 12" F--( u 12" (—"I O ..L 1 I 11 Ll L-- L- L-L L J U U- - - - 9 ON c{1 ASPHALT SHINGLE ROOFING � ell � (P FASCIA: 1X8 WITH CROWN 181g k- O TO MATCH EXISTING IXE w IK z a I w ll- ll. -ll_ _1 �L U_L. a L� L LL 4' Q� ll M u LJ LJ u LJ L1 C u u u - L1 u L LJ u L L L1 O W lt1 �. hly- L u L u u L L � - ASPHALT SHINGLE ROOFING /12" IT7 12 Z Z l'1 0 u u � u, L� u a " O W �l L L L L U U U U 1 1 ll.0-i L L Lj L1 u' 6 O Q U 1L u'L� i� u N 4. — T.O. PLATE N � U 4 f— j�/ (L — , " /lf — — — — — — u u SJu` a Lu u`� � u u �' Q uu L _ ,H/� w �-- Q N - 10 - 0 _ 5" OGEE GUTTER, BLACK B4O, HDR, GIRDER z O N - � T.O. DOOR/WINDOW � - - - - - 1' - 9" ` O N _ > O 1 O ff 6 CUSTOM WOOD TURNED HISTORIC — w O [L W O COLUMN PROVIDE SIMPSON CONNECTIONS ,6'-0" 1'-O" Q U u_ Q-AT TOP AND BOTTOM. TYP. W � H e O ,� �- 8"-10" VERTICAL D I � � _L BOARD SIDING TT _ O j I `� FIN, FL, - - - - - - - - GRADE O" GRAD r, GRADE iv ° ° a DE a o STEP TO GRADE BRICK PATIO �I St I Q z I I I z I I P.C. FOUNATION _ PER CODE i PAGE: 011 - - _ - - - - - AND FOOLING m — — — — — — — — — — — — — — — — — — — — — — — — — Historic Preservation Commission FOOL HOUSE - SIDE CLEFT) ELEVATION FOOL HOUS - _esoiution #: s � � M FRONT ELEV�TIOI�bated: � � '� 5 7 2 1/4" = 1'-0" 1/4" = 1'-0" N 0 N THESE DRAWINGS AND ACCOMPANYING SPECIFICATIONS,AS INSTRUMENTS OF SERVICE,ARE THE EXCLUSIVE PROPERTY OF THE ARCHITECT AND THEIR USE AND PUBLICATION SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED.REUSE,REPRODUCTION OR PUBLICATION BY ANY METHOD,IN WHOLE(OR IN PART,IS PROHIBITED EXCEPT BY WRITTEN PERMISSION FROM THE ARCHITECT.TITLE TO THESE PLANS SHALL REMAIN WITH THE ARCHITECT.VISUAL CONTACT WITH THEM SHALL CONSTITUTE PRIMA FACIE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. AREA CALCULATIONS: POOL HOUSE 350 SF COVERED PORCH 150 SF MAX. HEIGHT SEE SHEET A-4,0 FOR WINDOW AND DOOR SPECIFICATIONS. TYPICAL ROOF CONStRUCTON: 2A2 RIDGE - 2x RAFTER PER PLANS 2x10 R.R. f 16" O.C.. TYPICAL ROOF CONSTRUCTON: - 5/8" CDX PLYWOOD SHEATHING - 2x RAFTER PER PLANS (ZIP SYSTEM OPTION) t Ill, I u STRUCTURE IS SEASONAL - 5/8" CDX PLYWOOD SHEATHING - WEATHER BARRIER 4 UNINSULATED. 12 (ZIP SYSTEM OPTION) - ICE AND WATER SHEILD t0 CODE » Li u �� 12" - WEATHER BARRIER - ASHPHALT SHINGLE (BLACK g a g" - ICE AND WATER SHEILD TO CODE APPROVED H,P.C,) 2x8 R.R. 6� 16" O.C.. � - ASHPHALT SHINGLE (BLACK pi APPROVED H.P.C.) ATTIC 2x6 G.J. s 16" O.C. IL ATTIC ATTIC W/ WAINSCOTTING CLG. LO 5 OGEE GUTTER ACCESS O TO CC>DE 2xIO C.J. m 16" O.C. 12 5" OGEE GUTTER 2x10 C.J. 16" O.C. T.O. PLATE TYPICAL WALL CONSTRUCTON: a 4" ' lill - 2X6 WOOD STUD T.O. PLATE( N N 1/2" GWS ON WALLS 2x8 C.J. m 16" O.C. 10 - O' - 1/2" PLYWOOD SHEATHING I/;2" GWS ON WALLS AND _-_ 10 - O o O AND CELING - WEATHER BARRIER CEILING SPACKLE AND PAINT B.O. HDR. / p SPACKLE AND PAINT - RAIN SCREEN (BLACK) - - GIRDER w M T.O. DOOR/WINDOW „ „ l' g�� 4" P.C. SLAB ON GRADE - — - - - I x 8 410 VERTICAL BOARD SIDING. - - - — - - (3500 PSI MIN.) (2) 2x10 HDR. ' 0 LEFT TO WEATHER. '' T.O. DOOR/ W/ 6"X6" 10/10 W.W.M. ON O TTOM FLUSH TYPICAL WALL CONSTRUCTON: p GYM PORCH WINDOW 6 MIL VAPOR BARRIER ON _ - 2X6 WOOD STUD ' = l' - O" 2" RIGID INSULATION BOARD (3 O - 1/2" PLYWOOD SHEATHING 0 (2' HORIZONTAL AND GYM - WEATHER BARRIER 4" P.C. SLAB ON GRADE BRICK PATIO VERTICAL TO FOOTING) - RAIN SCREEN (BLACK) 13500 PSI MIN.) - 4" MIN. COMPACTED POUROl1S - 1" x 8"410" VERTICAL BOARD SIDING, W/ 6"X6" 10/10 W.W,M. ON STEP t0 GRADE FILL LEFT TO WEATHER. 6 MIL VAPOR BARRIER ON PER CODE FIN, FL, 2" RIGID INSULATION BOARD FIN. FL. N a ° - — - — o„ (2' HORIZONTAL AND VERTICAL TO - - - - ` - - 1 I FOOTING) I O�� T - I 4 MIN. COMPACTED POUROUS FILL E �— COMPACTED FILL _ „ �� - - 8 P.C. WALL ON = I COMPACTED FILL = 8 P.G. WALL ON 8 x16 - P.C. FOOTING 8" P.C. WALL ON _ I 8"xl6" P.C. FOOLING TO -3'-O" BELOW GRADE 8 x16 P.C. FOOTING OR SUITABLE SOIL. — TO -3-0 BELOW GRADE I — OR SUITABLE SOIL. i�00L OILS SECTION 1 COOL HOUSE SECTION( 2 f�{ t7 � QM 1 1I i ll V �� ' 1/4 = I -•O 1/4 = i -O w r m � mop � w � o z 5Ln M� Q Ld 5 20' - O" - pJU � Wcp A-2.6 PROVIDE TIE DOWNS AT EACH CORNER Lu - U 12' - 6" 6" 6' - oil 6' SIMPSON HDU 5 (TYPICAL) - SEE DETAIL 5 a X—Q -4 O ui SHEETS 5/8 ANCHOR BOLT. PROVIDE 4 1/2 Z_ Q nl MIN WOOD MEMBER TO ATTACH TO OBTAIN A-2 6 O 1810 LBS RESISTANCE U U PROVIDE 5/8 ANCHOR BOLTS 32 O.C. MAX. tu tu WINDOW #01 WITHIN 1' OF EACH SPLICE IN SILL PLATE 20' - 0" w ABOVE: MODEL 1 : SEE DETAIL SHEET FOR INSTALLATION J - - - - I — — I _ — — — — — — — zi a — — — — — — — — 'ARCHITECT: _ - - --I_c -i-� _ �- — — — — — — — — — — — — — — — — -I UTILITY I UTILITY o I t{1 ., r 1 �� F.. -- - ( _I �( 1 �� --l� - CLOSET CLOSET I I ° I I < \J \� - _ _ -- - - I TO APPROVED �IL-� 2x8 G.J, m 14 SANITARY SYSTEM. I I w .w `r �- - ° I �- - _j _ - -� _ - ATTIC 7 ! , -�r J c - - - -�- �_ - I \ / I 16 O.C. I MAINTAIN 10 L - - - ACCESS —► 03 I I : _ - _ �C ~�� - -_ �j -_ 02 t0 CO I I O ( BAIL I CLEARANCE TO _ - r DE 8 / � ] � 8-O CLG. HT, I I SANITARY PER CODE � L � i = (STONE FLOORING) �� �� �� -- - - _ I I I �9 I I 8 P.G. WALL ON 88 xl6 ��L I POOL HOUSE ,� I �� I - 1 ,�- ( c�-� ��=� 10'-0" 6LG. HT. 8'-O" CLG, HT. I 4 P.G. SLAB ON GRADE 13500 PSI MIN.) P.C. FOOTING paNIEL A. SUTLER;R.a. _ - -� I W/ 6"X6" 10/10 W.W.M. ON I Q I t0 -3'-0" BELOW GRADE g / 12 ---L - �c -9 / 12 (STONE 1 LOORING) � ) �� -� -�- 6 MIL VAPOR BARRIER ON OR RATEABLE SOIL. L.I-�L �-I �=i - - r r „ 2x8 C.J. I i- �4 I „ #�- - - - _ -- 2x10 C.J.I6 16 O.C. - — I - - I 2 RIGID INSULATION BOARD - - O.C. (2 (] II I - R I -_ _ _ _ C�� -�-_-- _ --- �_� � �- � � ' HO L D VERTICAL t0 FOOT 4 �_, _ L I J -J� -- 4 i i' I 4 I I 4" IM�N COMPACTED POUROUS FILL FOOTING) I O I- r c A-2.6 ='-L - _ - _ r -Cr - � !� ._ A-2.6 I I i 0 - A-2.6 C -ECG ��C - - O1 w p I I � u p - I I I I z _ O I I - I NOTE: O u 8" 8u I z � RESAR FOR POOL U I HOUSE AS (2) "4• IN Q tu M W FOOTING AND (IJI 4 a W � O Q �Q } _ RESAR WITHIN 12 OF U O Z OI I = - - - - - - a- - - - - - TOP OF FOUNDATION P4 Z Q - D IX S M O W = O O Q I - - - - - AND (1) 4 NEAR MID _Q 5" OGEE GUTTER ���� �� I r - - - - - - ~ Q d - - C R R. I ' �, I HEIGHT OF - J 1 L J J LJ J L` L Li Li U Lam-- _ 2x8 Y�� \�� - "% �, a FOUNDATION WALL. W O _�_ r _ 1 L_I ' LJ J. � � III III 'I I I I ! III 6" / 12"; - _� - - L1:1_LJ._LL � J LJ � •� 16" O.C, i \•� 2x8 R.R. 16 O.C. I w I I � 12" -- 1_JJJ 1l._LI.1 J1 liJL J_.11L1LJ L l JJ I = U �� � `� I _ I I — DROP WALL FOR SLAB } I I W W UI O Q dl J1 I_.1 L...1Lil_JLU Il ILL J _ I r' .9�, � � �� 0 Q cv x r 8 P.C. WALL ON $ xl(o I- Z IJ J 11 U L I Li L I L' L I L LI ' .L 1 J 1 Ll 1l.ll. Il .11 J JL - �� - _ _ < " -'� x I I I Q Q C=-= _ J J I J L'I.J J LL LI J LI L1_`! 1J U du L L U L LIJ l LI L1L1 fJ!J�J -- i �''� � ��� � ' R CK �I� "���`� �� �� � � -� �4 � P.C. FOOTING � } c\v � I TO 4-0 BELOW GRADE O a *' tll _cam L LLJL J_LJ U_L LLU i L!LJJ \ JJ r I m COMPACTED FILL W O Q llJ.llJJ JELL= l�_1_ LL — r-- d L 11 U L :I L L L L_ I L L LI I J_ 11 IJ_LI I l lJ Au, �Jl OR SUITABLE SOIL. L1 J LJ J L;LJ I LJ.J LI J'_L LJ l J L J L LJ LJ L'U LJ U LJ LI U"LJ J LA -j_ N� t i I— :c JJ l _JLl_JJ1 1J-J L 1U.Ll JL JJJL UL-JIJL��JL1J' L L L III L _�� L — — — — — — — — — — — — — — — — — J F-� _Q U to J_1�LWi 1llJJ LLL-L L._i L_ JJ L1llL.J_J���� — _ - lJ J IJ Il J U L1 U U L L L L_L L L 1 L 111 -U 11 U.Ll U L' J U Ll ! I c� WOOD COLUMNS ABOVE Q JJ� �I J` I I 6" CUSTOM WOOD TURNED O U- I I lJ I_ ILL :I L IJ I; L L11 J l l J L -L1 J 1�1.1 U J l l I l_I i III L i;l 1l IJ L U L' L Il L LJ ;I N ? I �\I HISTORIC COLUMN t0 - - - - - - - - - - - - - - - - L- - MATCH THE MAIN HOUSE, a-+ 12' 6" 6' - 6" 6" PROVIDE SIMPSON N Z STEP TO GRADE CONNECTIONS AT TOP 8 18 - 8 O .. PER CODE 12" 6' - S" a - 4" 4' - 11" 12" AND BOTTOM. TYP. U W O.H 20' - 0" H. Q FADE: FOOL HOUSE ROOF PLAN FOOL HOUSE FLOOR �'1..AN i�OOL HOUSE FOUNDATION PLAN Historic Preservation commission 3' 1/4" = 1'-0" 2 1/4" = 1'-O" 114" = 1'-O" Resolution#: S. N Dated: r� G,9'S s i-i 2 ,96 07-: LO N O N LO THESE DRAWINGS AND ACCOMPANYING SPECIFICATIONS,AS INSTRUMENTS OF SERVICE,ARE THE EXCLUSIVE PROPERTY OF THE ARCHITECT AND THEIR USE AND PUBLICATION SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED.REUSE,REPRODUCTION OR PUBLICATION BY ANY METHOD,IN WHOLE OR IN PART,IS PROHIBITED EXCEPT BY WRITTEN PERMISSION FROM THE ARCHITECT.TITLE TO THESE PLANS SHALL REMAIN WITH THE ARCHITECT.VISUAL CONTACT WITH THEM SHALL CONSTITUTE PRIMA FACIE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. Road APPROVED AS NOTED D P.TE:��� a5 B. # J I F "L _ COMPLY WITH ALL CODES OF F y`_ BY NEW YORK STATE&TOWN CODES AS REQ IRED AND CONDITIONS OF NOTIFY BUILDING DEPARTMENT AT SOROWTOt►.'NZQ.l 631-765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: SOU41011ITMINPW3P'NGBOAM FOUNDATION-TWO REQUIRED SOUTHOIDTOd"' MUSTEES FOR POURED CONCRETE N.Y.S.DEC ROUGH-FRAMING&PLUMBING 05,a3.aoay. ,2 SOUTHOLDHFC INSULATION 1�' �' �.� SUID -C)S-,2 q FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW ELECTRICAL YORK STATE. NOT RESPONSIBLE FOR INSPECTION REQUIRED DESIGN OR CONSTRUCTION ERRORS PLUMBER CN��B FORE ON LEAD CO All exterior lighting CERTIFICATE OF OCCUPANCY Installed,replaced or SOLDER USED IN WA repaired shall conform SUPPLY SYSTEM CANNOT to Chapter 172 EXCEED 211 of the Town Code PLUMBING t,LL PLUMBING WASTE &WATER LINES NEED TESTING BEFORE COVERING RETAIN STORM WATER RUNOFF PURSUANT TO CHAPTER 236 OF THE TOWN CODE • A I A i New York State Law You Must Call 811 Before You Dig �( 'I ' o POOL HOUSE DOOR SCHEDULE AREA CALCULATIONS: WINDOW FALL PROTECTION: POOL HOUSE 350 SF PROVIDE WINDOW FALL PROTECTION AS REQUIRED SY CODE. EGRESS ° o DOOR COVERED PORCH 150 SF WINDOW MUST MEET MINIMUM CLEAR OPENING OF 24" HEIGHT, 20" WIDTH, AND113 5.1 SQ,FT, NO, LEVEL DOOR TYPE WIDTH HEIGHT THICKNESS REMARKS OPENING PROTECTION E N BY WOOD STRUCTURAL PANELS PERSUANT TO ILI 01 IST FLOOR (FIN.) CUSTOM 2-6 1-O 1 3/4 z 16013 1.4, SEE FASTENING SCHEDULE ON DETAIL SWEET IN THIS SET, 0 0 02 IST FLOOR IFIN,) D 6-011 1'-Ol' PER MANUF, a 03 IST FLOOR (FIN,) JEI 2'-6" 1'-O" 1 3/411 SEE DETAIL SHEET FOR HIGH WIND CONNECTION REQUIREMENTS o ul Q WINDOW ( I z a FOOL HOUSEWINDOW SCHEDULE SEE SHEET A-4,0 FOR WINDOW AND DOOR SPECIFICATIONS, u o � WIDTH HEIGHT HEAD a 8 NO. LEVEL WINDOW TYPE (F.S.) HEIGHT MODEL REMARKS 01 IST FLOOR (FIN.) DOUBLE HUNG 48-1/4" 64-7/8" 4121 Q 02 IST FLOOR (FIN•) DOUBLE HUNG 48-1/4" 64-1/8" 1' - O" 4121 0 03 IST FLOOR (FIN.) DOUBLE HUNG 56-1/8" 64-1/8" 1' - O" 41321 0 "' r 04 IST FLOOR (FIN.) DOUBLE HUNG 25-5/5" 44-1/8" 1' - O" I811 w 05 IST FLOOR (FIND FIXED 6011 48" it - oil CUSTOTI o 0. J 06 IST FLOOR (FIN.) FIXED 24" 24" 15' - O" 1818 z � o 01 IST FLOOR (FIN.) FIXED 2411 2411 15 - O" 1818 ° 0 a o MAX. HEIGHT = 22'-0" MAX. HEIGHT = 22'-0" CONTINUOUS RIDGE VENTING - u- I -U- u _L L _ L u- ul u u � LI 11_ _Ll L L' L ASPHALT SHINGLE ROOFING ll_1 I11,1 L L- _li - _, L_ _J Ll 1J u L_ 11 / N 12 L LJL\ u L . t IBIS " FASCIA: 1X8 WITH CROWN 9 IX a ASPHALT SHINGLE ROOFING TO MATCH EXISTING 1211 IT�du : u u I U u: - 5" OGEE GUTTER, BLACK 911 5 OGEE GUTTER, 12" 1 U- 4. >� 11 BLACK 411 N - L_. �� � u L - Ll -y- - - - � - - - - T•O• PLATE - - - - ILJ `V B.O. HDR• GIRDER _ O 1 - 911 - - - - - T.O. DOOR/WINDOW � 1 — oil ■ ar 6" CUSTOM WOOD TURNED 'HISTORIC' II 11 O W COLUMN PROVIDE - p 8 -10 VERTICAL BOARD SIDING x SIMPSON CONNECTIONS j AT TOP AND BOTTOM. (] X tu Z LL TYP. u�i z j O I ; BRICK PORCH j IA O C1, FIN. FL. � O = cfD `14 e GRADE oil Cv b a , GRAD C"+ Q- (Y OO STEP TO GRADE I I PARGED EXPOSED I Z_ PER CODE � I I CONCRETE FOUNDATION I I P.C. FOUNDATION AND FOOTING m - - - - - - - - - - - I_ m - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - -1 L- - - - - - - - - - - -- - - - - - - - - - - - - - - - Ul W � FOOL MOUSE - SIDE (RIGHT) ELEVATION OOL HOUSE - REAR ELEVATION 114 = 1'-0° 114" = 1'-0" ARc+ iTEc\ ARCF;Irc�` BUTC \ 030�y2�P�1j f` MAX. HEIGHT = 22'-0° MAX, HEIGHT = 22-0 `�, E O`� — — — — — — — — — — — — — — DANIEL A. BUTLER, R.A. CONTINUOUS RIDGE VENTING Ll O LLj Lj j Li Li -L� >�. u ULi u u L_ u u 1211 A L L 1211 H J LL ji Li 11 Li LJ L- -L u U u ASPHALT SHINGLE ROOFING 911 g11 3: }- LL \ . J �� FASCIA: IXS WITH CROWN I818 A ii -fly 1� u u _� I Lu u u L llu TO MATCH EXISTING IXE �] Z Lu U LJ L1 LJ1 LJ� J L L _ IJ �L J L1 - :_� O O O {,j } 11 u . U J L.L� J u 4 ASPHALT SHINGLE ROOFING /12 12" Z Z z u- L 1J J-u�.1J 11 O 11 -J- - �i u u u L u LiY u L LJJ L11 J �a iv 1� q¢" - T.O. PLATE - - - - - - 6 N 611 O A U L L Lu a _ � �f - - _ csJ A d 10' - pll LiJ LY U- LU J_'UL,7LU- L�U\ �U JLTL JUJ L J�J L L� j L LU L L, _ _ _ u J _ UJ U A U J - 5" OGEE GUTTER, BLACK B.O. HDR. T717 IG RDER [� � w z O V O N T.O. DOOR/WINDOW - p11 - - - - - - it - ell rTl O } O w " � ,n j 6" CUSTOM WOOD TURNED 'HISTORIC' ,' p- Q N COLUMN PROVIDE SIMPSON CONNECTIONS to'-0" 1'-O"� / AT TOP AND BOTTOM. TYP. ' W ` a O O ,� �- H e cv z 8"-10" VERTICAL � D � BOARD SIDING 011 FIN, FL. n O z 111 ° . ° ° a ° - - - GRADE - — - p11 - - — - - — - — - GRADE �+ C O GRADE �, ° ° ° - A z i i i BRICK PATIO i STEP TO GRADE I z I I P.C• FOUNATIDN _ PER CODE i PAGE: `4 I- - - - - - - - - - - AND FOOTING m 1--1 - - - - - - - - -� � - - - - - - - - - - -- - - - - - - - - - - - - - - � m E° �1 r I W I Fr, M fl POOL HOUSE - SIDE (LEFT) ELEVATION POOL HOUSE - FRONT ELEVATION. , ! A-2 ',05 M 7: 2 11411 = 1'-011 v4" = I'-o11 y, 2025 N 0 N tl$ 1140 THESE DRAWINGS AND ACCOMPANYING SPECIFICATIONS,AS INSTRUMENTS OF SERVICE,ARE THE EXCLUSIVE PROPERTY OF THE ARCHITECT AND THEIR USE AND PUBLICATION SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED.REUSE,REPRODUCTION OR PUBLICATION BY ANY METHOD,IN WHOLE:OR IN PART,IS PROHIBITED EXCEPT BY WRITTEN PERMISSION FROM THE ARCHITECT.TITLE TO THESE PLANS SHALL REMAIN WITH THE ARCHITECT.VISUAL CONTACT WITH THEM SHALL CONSTITUTE PRIMA FACIE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIbcfJS`.b 1 t`0 Juud au1 II AREA CALCULATIONS: POOL HOUSE 350 SF COVERED PORCH 150 SF MAX, HEIGHT 22' - 0" TYPICAL ROOF CONSTRUCTION: SEE SHEET A-4,0 FOR WINDOW AND DOOR SPECIFICATIONS, 2x12 RIDGE - 2x RAFTER PER PLANS 2x10 R,R, 6 16" O,C„ TYPICAL ROOF CONSTRUCTON: - 5/8" GDX PLYWOOD SHEATHING - 2x RAFTER PER PLANS (ZIP SYSTEM OPTION) _a u �_u u _u I STRUCTURE IS SEASONAL III - 5/8" GDX PLYWOOD SHEATHING - WEATHER BARRIER E UNINSULATE•:D, Al 12" (ZIP SYSTEM OPTION) - ICE AND WATER SHEILD TO CODE u 12" - WEATHER BARRIER - ASHPHALT SHINGLE (BLACK a 9" - ICE AND WATER SHEILD TO CODE APPROVED H.P,C,) W g� `\ - ASHPHALT SHINGLE (BLACK 2x8 R.R. g 16 O,G„ APPROVED H,P.C,) ATTIC 2x6 C,J, *+ 16" O,C, ATTIC 5" OGEE GUTTER ATTIC W/ WAINSCOTTING CLG, ACCESS - TYPICAL WALL CONSTRUCTION: t0 CODE 2x10 G.J. 10 16" O,G, 12 4115" OGEE GUTTER O 2x10 C,J, 16" O,G, T.O. PLATE - - - 2X6 WOOD STUD _ T.O. PLATE N - 1/2" GWB ON WALLS i 10 - O" - 1/2" PLYWOOD SHEATHING I/2" GWB ON WALLS AND 10' - O" z O 2x8 C,J, 16 O,C, --- o AND GELING - WEATHER BARRIER CEILINIG SPACKLE AND PAINT B.O, HDR. / p ER LLJ SPACKLE AND PAINT - RAIN SCREEN (BLACK) _ GIRD 4" P,C, SLAB ON GRADE - T,O, DOOR/WINDOW - — - - - �� - 1" x 8"410" VERTICAL BOARD SIDING. J (3500 PSI MIN,) (2) 2x10 HDR. ' - LEFT TO WEATHER. ' N��W�INDOW DOORW/ 6"X6" 10/10 W,W,M, ON I O ttOM FLUSH TYPICAL WALL CONSTRUCTON: I p ' GYM PORCH6 MIL VAPOR BARRIER ON I - - 2X6 WOOD STUD I ' - 2 RIGID INSULATION BOARD O - 1/2" PLYWOOD SHEATHING _O ' l2' HORIZONTAL AND GYM - WEATHER BARRIER 4" P.C. SLAB ON GRADE I BRICK PATIO VERTICAL TO FOOTING) I - RAIN SCREEN (BLACK) (3500 PSI MIN,) ( - 4" MIN, COMPACTED f'OUROUS - I" x 8"410" VERTICAL BOARD SIDING, W/ 6"X(o" 10/10 W.W.M. ON --- STEP TO GRADE FILL LEFT TO WEATHER, 6 MIL VAPOR BARRIER ON PER CODE FIN, FL, 2" RIGID INSULATION BOARD4s I I FIN, FL, - - — l2' HORIZONTAL AND VERTICAL TO - _ d - - - - 0 p N ( I_ I - I FOOTING) 4" MIN, COMPACTED POUROUS FILL - COMPACTED FILL z - - — - - 8" P.C. WALL ON _ COMPACTED FILL = = 8" P.C, WALL ON 8"x16" P.C. FOOTING - = 8" P,G, WALL ON _ I - 8"x16" P,C, FOOTING t0 -3'-0" BELOW GRADE 8 x16 P.C. FOOTING — — OR SUITABLE SOIL, I I TO -3'-0" BELOW GRADE I P — OR SUITABLE SOIL. POOL HOUSE SECTION 1 POOL HOUSE SECTION 2 01 A—I Q (� r CV a QC tY) E—+ o Z '� 5 5 20' - 0" a p JU (L C4 A-2.6 PROVIDE TIE DOWNS AT EACH CORNER to 12' - 6" 6" 6' - O" 6' SIMPSON HDU 5 (TYPICAL) - SEE DETAIL 5ul d Q O SHEETS 5/8" ANCHOR BOLT, PROVIDE 4 1/2" A-2.6 uut z -4 Z m 6 - ell 13 3 MIN WOOD MEMBER t0 ATTACH t0 OBTAIN 4 O � � Uct) U 7810 LBS RESISTANCE WINDOW * PROVIDE 5/8" ANCHOR BOLTS 32" O.C. MAX, w w WITHIN 1' OF EACH SPLICE IN SILL PLATE ABOVE:: 20 — O MODEL 10163 SEE DETAIL SHEET FOR INSTALLATION F- --------------- - --------------------------- - ---� — — — — — — — — ARCHITECT: UTILITY I UTILITY o I il ° I — — — — — —� CLOSET CLOSET I • \�1ERED�R�* ` TO APPROVED _ a I SANITARY SYSTEM, ATTIC V 2x8 C.J. �+ I � • I MAINTAIN 10 . _ ACCESS �� I 03 16 O. 1/2 BATH I CLEARANCE TO TO CODE I I �� I 8 o CLG, HT, 3 y_/ I SANITARY PER CODE IL I (STONE FLOORING) I I a I �-j if _ ,� - _- POOLtHOUSE i I i � I I �� I I 8 P.C. WALL ON 8 x16 , 4 P,G, SLAB ON GRADE (350o PSI MIN.) P.C. FOOTING DANIEL A. BUTLER, R.A. 10-O 6LG, HT, 8-O CLG, HT, - iv �� a �� I I I W/ 6 X6 10/10 W,W,M, ON I I TO -3-0 BELOW i GRADE - I ( OORING)12 - ���d'J �_ r I STONE 1 L I 6 MIL VAPOR BARRIER ON I I OR RATEABLE SOIL. J - - �. �� _ _ - r I „ I I 2x8 G.J. s I r I „ fa - - �t 2x10 C.J. 16 O,C. - 1 F- C ,� I 2 RIGID INSULATION BOARD - C -�- - l2' HORIZONTAL AND VERTICAL t0 FOOTING) --r L _ J� _ _ 1 4 I �4 J I _ -__ - _� - _ � � -� � - � - I 115; � � 4 - I 4" MIN. COMPACTED POUROUS FILL A-2.6 - C , � � A-2.6 I 10 A-2.6 - ( - I- C I L —,� I I t--r-I-t-' 1O1 i O O I I • I NOTE: rl-- - - � rI_ - - - N lg 8 Z O_ -kelp 8 l� - -1 = i i I m i _' I HOUSE AS (2) *14 IN LL )' W J � �� `� I I FOOTING AND (1) *4 a w W O O to } —�_ I � �� �- - I i I I I 4 REBAR WITHIN 12" OF V l� O Z O _ _ pg I - TOP OF FOUNDATION O w 4 IX 02 _ • a AND (1) *4 NEAR MIDA- _�� — — — — — — — — — — — — — — O Q U ~ QC iL 5 OGEE GUTTER �� HEIGHT OF 2x8 R,R, I " ,f> j z� � �f.� ,� � ~ J IJ L UPI LJ ,-L 1 L L T_J LJ L LJ LJ L �,,- „ I ,\ �U �. J{N VW Y �.��.� I 2x8 R.R. � 16 O,C, I � I I FOUNDATION WALL, � U O Q � II I 1 I! L-11llLllU - =6 / 12 , I } (k/ 1L L1L_ _��_�W1. 1' �p �\ r _ p DROP WALL FOR SLAB I I � LUU 1U O N L II L I L L_L L= Ltl. J_ 1 1J LI 11 L1 I LI II L, I_ y � f, _ �0 I I 8 P.C. WALL ON 8 xl6 Z - _ _JJ JI L�LJ 1 LL_1J LI IJ Ll-" LI LL J L L-1U L I LIJ L 1U 1J 1� �- , �� '\ ` \ ``\ 3R CIG f _tQ - L111_llJJ JJ_L�Lu \ `� �_ I P,c, FOOTING O O 7 I I t0 -3-0 BELOW GRADE O cal a) l� i11LL= J �' I I`'� ` y �n I r I COMPACTED FILL " �' O O I L L f L 1.1 I:I L J J I'' J J I, ll J 1I ,lJ I I IJ J Il L (l �� _ - :\ '� 1 3) Y .x ,'1!2 F ;•Y X. � I I I I OR SUITABLE SOIL, �i CL k � N �J H J L LJ'J L LJ J U LI Il__L L J 1J L _.J LJ L1,J L LJ LJ L L1 UL J U1J �L1Jii ��•� � � �� �i �l. I -_ LJ 1 LL1_JJ LJ�llllJll LI JL LI i x — — — — — — — — — —L F-� Q - - �L1LJJ llJ1L�L LLJ11 J �Wl _ I I ,� _ — — — — — — — U L I 6 CUSTOM WOOD TURNEDIL - i LI J IJ ��' �T � IJ _ U Ll L:_J L I �i L�LI J L L J LI L:� J Ll � L L LI Ll IJ LI ' U L '. 11 _l) '.I II _ v � � � I � I c� I WOOD COLUMNS ABOVE � � � O Il L L :I-L L.!I L VJ il. L lJ I. J L I J LJ I: 1J ��_II LI LJ 11 JI LI a II a-II ,u L ,I 1:L Il _L IJ ;I ? I ' j , H15toR1c COLUMN t0 — — — — — — — — — — — O fQ :I �' i — — — — — - - -- MATCH THE MAIN HOUSE, f� tt) H 12' 6" 6' - 6" 6"' PROVIDE SIMPSON CIA STEP TO GRADE CONNECTIONS AT TOP 8�� 18' - 8" CO PER CODE 12" 4' - 11" 12" AND BOTTOM, TYP, 0 zta O,H 20' - O" H, Q PAGE: POOL HOUSE ROOF PLAN POOL HOUSE FLOOR FLAN POOL HOUSE FOUNDATION FLAN .3 1/4" = 1'-0" 2 A�2 ,06 N r: st co/ O N THESE DRAWINGS AND ACCOMPANYING SPECIFICATIONS,AS IINSTRUMENTS OF SERVICE,ARE THE EXCLUSIVE PROPERTY OF THE ARCHITECT AND THEIR USE AND PUBLICATION SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED.REUSE,REPRODUCTION OR PUBLICATION BY ANY METHOD,IN WHOLE(OR IN PART,IS PROHIBITED EXCEPT BY WRITTEN PERMISSION FROM THE ARCHITECT.TITLE TO THESE PLANS SHALL REMAIN WITH THE ARCHITECT.VISUAL CONTACT WITH THEM SHALL CONSTITUTE PRIMA FACIE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. en