Loading...
HomeMy WebLinkAbout52006-Z �o�aoF soulyo`o Town of Southold * * P.O. Box 1179 �o�X 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 47282 Date: 08/12/2026 THIS CERTIFIES that the building ACCESSORY-NEW STRUCTURE Location of Property: 605 Saltaire Way Mattituck, NY 11952 Sec/]Block/Lot: 100.4-19 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 05/09/2025 Pursuant to which Building Permit No. 52006 and dated: 06/17/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Accessory storage shed (unconditioned) as applied for. The certificate is issued to: Richard Kalich,Mary Motto Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 52006 4/27/2026 PLUMBERS CERTIFICATION: utho ' e Si ature of sobTyo`p TOWN OF SOUTHOLD BUILDING DEPARTMENT ' TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52006 Date: 06/17/2025 Permission is hereby granted to: Richard N Kalich 605 Saltaire Way Mattituck, NY 11952 To: demolish existingshed and construct accessory storage building/shed (unconditioned) as applied for. Premises Located at: 605 Saltaire Way, Mattituck, NY 11952 SCTM# 100.4-19 Pursuant to application dated 05/09/2025 and approved by the Building Inspector. To expire on 06/17/2027. Contractors: Required Inspections: Fees: Accessory-New Structure $402.50 CO Accessory $100.00 DEMOLITION $64.00 4Total S566.50 ------------------------------ Building Inspector *pF SO�ryO�o Town Hall Annex Telephone(631)765-1802 54375 Main Road w P.O. Box 1179 Southold,New York 11971-0959 ��yCOUNT`1,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Richard N Kalich Address: 605 Saltaire Way city: Mattituck St: NY zip: 11952 Building Permit#: 52006 Section: 100 Block: 1 Lot: 19 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Electrician: Paul Burns Electrical License No: 3897ME SITE DETAILS Office Use Only Commercial Indoor X Basement Service Solar Residential X Outdoor X 1st Floor X Pool Battery Storage As-built Renovation 2nd Floor Hot Tub EV Charger New X Addition Attic Spa Generator Survey Mezzanine Garage X I Dock INVENTORY Service 1 ph In-wall Heater Recpt 5 Ceiling Fixtures 9 Smoke Detectors Pump Service 3 ph Hot Water GFCI Recpt 2 Wall Fixtures 4 CO Detectors Heater Main Panel A/C Condenser Single Recpt RecessdFixtures Combo Smoke/CO 1 Transformer Sub Panel 50A A/C Blower Range Recpt Ceiling Fan Heat Detectors Salt Gen Transfer Switch Mini Split Dryer Recpt UC Lights Fridge AutoCover ARC Blower Heads Switches 1 Pucks Lights Dishwasher Mini Fridge GFI SepticDisconnect Emrgency Strobe 4'LED Microwave Garbage Disp. ARC/GFI ERV Exit Lights Bath Exhaust Hood Dehumidifier Other Equipment: 50A Panel 12 Circuit/6 Used Notes: Acc. Garage Inspector Signature: Date: April 27, 2026 �oAN*tf 50pTjolo # * TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ OUNDATION 1 ST/ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: lie KO DATE J INSPECTOR �aoe souTyo do �o # # TOWN OF SOUTHOLD BUILDING DEPT. ^ou�m,� 631-765-1802 'o' INSPECTION ' [ FOUNDATION 1 ST/ REBAR [ ] -ROUGH PLBG. .] F NDATION 2ND. [ ] INSULATION/CAULKING [ FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE`SAFETY INSPECTION ] FIRE RESISTANT CONSTRUCTION [ ]. FIRE RESISTANT PENETRATION ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] /EC [ ] RENTAL KS: )INCLwe oz DATE I o I ?�Iy> INSPECTOR *q SOUTyOlo — # # TOWN OSOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION ' [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION F LECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE �-S INSPECTOR ��. OE SOUIyOlO a57 --- * # TOWN OF SOUTHOLD BUIL� DE . ,/ cou 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: AJ DATE Ll INSPECTOR pF SObTyo� # TOWN OF SOUTHOLD BUILDING DEPT. coorm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ;��L ATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION. [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: fN DATE 11 INSPECTO �ao�� r . _ ..-,.r..._....,..ww. _ .. . _ . . . 4>�Qos�ff0(,r�o`y�I TOWN OF SOUTHOLD—BUILDING DEPARTMENT y n Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY l 1971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownnyiov Date Received APPLICATION FOR BUILDING PERMIT 6 L For Office Use Only D EC E HE PERMIT NO. a Building Inspector: I MAY — 9 2025 Applications and forms must be filled out in their entirety. Incomplete Building Department applications will not be accepted. Where the Applicant is not the owner,an Town of Southold Owner's Authorization form(Page 2)shall be completed. Date:5/9/2025 OWNER(S)OF PROPERTY: Name:Mary & Nate Kalich SCTM#1000-100-1-19 Project Address:605 Saltaire Way Phone#:(917) 334-6639 T—Email:marymotto@yahoo.com Mailing Address:605 Saltaire Way, Mattituck NY 11952 CONTACT PERSON: Name:Adam Volosik Mailing Address:South Harbor Rd, Southold NY 11971 Phone#:(631) 806-2537 FFmail:avolosik@gmail.com DESIGN PROFESSIONAL INFORMATION: Name:Adam Volosik Architect Mailing Address:South Harbor Rd, Southold NY 11971 Phone#:(631) 806-2537 Email:avolosik@gmail.com CONTRACTOR INFORMATION: Name:TBD Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ®New Structure ❑Addition ❑Alteration ❑Repair RDemolition Estimated Cost of Project: ❑Other .A. $ Will the lot be re-graded? ❑Yes BNo Will excess fill be removed from premises? ❑Yes ®No 1 PROPERTY INFORMATION Existing use of property:Residence Intended use of property: Residence Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R-40 this property? ❑Yes R No IF YES, PROVIDE A COPY. R Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted B AdamVolosik pp y(print name): RAuthorized Agent El Owner Signature of Applicant: AP-0164NIE Date: 5 D.BUNCH I 1 Notary Public,State of New York STATE OF NEW YORK) No.01BU6185650 Q ualified in Suffolk County SS: Commission Expires April 14,2��,' COUNTY OF ) being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the (Contractor,Agent, Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this qLl-)ay of 20 CI�15 Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I Cn1 C I JN residing at Sa /�) j W� r f`I J ado hereby authorize do m vrl /0 .S 1' to apply on my behalf.to the Town of Southold Building Department for approval as described herein. k4l�cl n` � I MOwner's Wature Date A CL-\ Print 0 ner's Name L UFF01 BUILDING DEPARTMENT- Electrica�h11n pector ca� TOWN OF SOUTHOLD NOV 6 2025 F�' o Town Hall Annex- 54375 Main Road - P Box 1179 y '? Southold New York 11971-0959 y,• Q' `` '��` Telephone (631) 765-1802 APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required), Date: 6/17/25 Company Name: Paul Burns Electrical Contractors Inc Electrician's Name: Paul R Burns Jr License No.: 3897-ME Elec. email: pburns1106@gmail.com Elec. Phone No: 631-365-4735 01 request an email copy of Certificate of Compliance Elec. Address.: PO Box 1061 Southold, NY 11971 JOB SITE INFORMATION (All Information Required) Name: Kalich Address: 605 Saltaire Way Mattituck Cross Street: Wavecrest Lane Phone No.: Bldg.Permit#: 52006 email: pburns1106@gamil.com Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Wire detached storage building Square Footage: 528 Circle All That Apply: Is job ready for inspection?: 0 YES ❑ NO 7 Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES 0 NO issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION P6 I �1:)o UU �u F04 BUILDING DEPARTMENT- Electrical44pector t wr�J L-� TOWN OF SOUTHOLD s Town Hall Annex- 54375 Main Road ° Box 1179 coo ,Southold New York 11971-0959 ,�, yY �5p-�y Telephone (631) 765-1802 APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 6/17/25 Company Name: Paul Burns Electrical Contractors Inc Electrician's Name: Paul R Burns Jr License No.: 3897-ME Elec. email: pburns1106@gmail.com fol Elec. Phone No: 631-365-4735 ❑1 request an email copy of Certificate of Compliance Elec. Address.: PO Box 1061 Southold, NY 11971 JOB SITE INFORMATION (All Information Required) Name: Kalich Address: 605 Saltaire Way Mattituck Cross Street: Wavecrest Lane Phone No.: Bldg.Permit#: 52006 email: pburns1106@gamil.com Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Wire detached storage building Square Footage: 1528 Circle All That Apply: Is job ready for inspection?: YES ❑ NO 0✓ Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES 0✓ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION pc� ��o PERMIT# Address: Switches Outlets G F I's C 1 Surface Sconces H H's UC Lts Fridge HW POOL Fans Mini Fr. W/D PanelPump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower AC AH Hood Blower Service Amps Have Used Sub Amps bA Have I `7 Used Comments �i II �t ABBREVIATIONS SYMBOL KEY EXTERIOR DOOR SCH. - SIMPSON DRAWING LIST is @❑ AT MIN.[❑ MINIMUM WALL CONSTRUCTION 14, ACOUST.0 ACOUSTICAL MISC;.L) MISCELLANEOUS O QUAN TYPE MANUFACT'R & UNIT No. SLAB SIZE (WxH) ARCHITECTURAL: A-SERIES om'� A.D.❑ AREA DRAIN MTD!.❑ MOUNTED CONSTRUCTION ABOVE ADJUS.0 ADJUSTABLE MTL..❑ METAL A 1 SWINGING 7860 T-0"x 6'-8" R.: .. A 0.1 COVER SHEET WIND LOAD DIAGRAMS ARCHITECT A.F.F.Li ABOVE FINISHED FLOOR #❑ MATERIAL -��� DENOTES DIM OPONITOO (WINDOWS) NOTES: A 0.2 SPECIFICATIONS 528 SOUTH HARBOR ROAD SOUTHOLD, NY 631 806 2537 ALUM.❑ ALUMINUM N.A.Lu NUMBER OR SIZES APPROX.❑ APPROXIMATE N.LC:.0 OR DO NOT APPLICABLE A 0.3 SCHEDULES ARCH.❑ ARCHITECT,ARCHITECTURAL NO.❑ NOT IN CONTRACT 1. ALL UNITS TO BE PAINTED BLDG.[] N.T.S.0 NUMBER DENOTES DESIRED ALIGNMENTS OF BLDG. FINISHED SURFACES OR ELEVATIONS A 1.0 SITE PLAN BLK.❑ BLOCK O.CALJ NOT TO SCALE BLKG.0 BLOCKING O.D.[❑ ON CENTER _ BM.0 BEAM O.H.I❑ OUTSIDE DIAMETER DENOTES CENTERLINE UNLESS OTHERWISE SPECIFIED A 2.1 PLANS BOT.❑ BOTTOM OPP'.❑ OPPOSITE HAND A 3.1 ELEVATIONS B.P.❑ BUILDING PAPER PERIIM.0 OPPOSITE BSMT.❑ BASEMENT PERIP.❑ PERIMETER SECTION/ELEVATION NUMBER A 3.2 BUILDING &WALL SECTIONS B'TWN.0 BETWEEN PG.❑ PERPENDICULAR 1 CL ❑ CENTERLINE PL.❑1 PAGE A0, DRAWING SHEET NUMBER CAB.0 CABINET PLUIMB.❑ PLATE CER.❑ CERAMIC PLY\WD.❑ PLUMBING CL.0 CLOSET PR.CI PLYWOOD DETAIL NUMBER 1 fyP ,0 ED AS NOTED� C LG.❑ CEILING P.S.IF.0 PAIR A0. �j DRAWING SHEET NUMBER - COLU COLUMN P.S.II.U PER SQUARE FOOT B.P. . CONCRETE P.T. POUNDS PER SQUARE INCH DATE. �, Y. �:Q4f?�,y��. ���C®pES 0 CONC.❑ CONC FEE ---e — NEW YORK S ATE&TOWN CODES CONST.❑ CONSTRUCTION PTD.LI PRESSURE TREATED 1O EXTERIOR WINDOW/DOOR NUMBER NOTIFY BUILDING DEPARTMENT AT IDS REQUIRED D TT�O NDITIONS OF CONT. CONTINUOUS P.V.(C.Li PAINTED CPT.0 CARPET QTY'.❑ POLYVINYL CHLORIDE 631-765-1802 8AM TO 4PM FORTH �0 �� CTR.0 CENTER R❑ QUANTITY 1O INTERIOR DOOR NUMBER FOI.I r���t±nl(�INSPECTIONS' C.V. CLEAR VERTICAL GRAIN R.D.U RADIUS, RISER 1 ,i, •�,'�,TI{)py-T1P+10 REQUIRED 0 ID TOWN PLANNING BOARD j},��Tj CONCRETE 0 iiOLDTOWIdTRUSTEES C. .G U D.❑ DRYER REF RIG.❑ ROOF DRAIN =. r -+t�Pu ING&PLUMBIN DIA.L! DIAMETER REINF.❑ REFRIGERATOR O-- WALL CONSTRUCTION TYPE 3 I I do, DIM.❑ DIMENSION REQ'D.LI REINFORCING 3 �r IIUN �• }-I�SAL-CONSTRUCTION MUST OUTHOLD HPC DN.❑ DOWN RF.❑ REQUIRED ELEVATION DESIGNATION ABOVE 0'-0" VI:-COMPLETE FOR C.O, CHD D.S.0 DOWNSPOUT RM.[U ROOF + DATUM UNLESS OTHERWISE SPECIFIED ALL CONSTRUCTION SHALL MEET THE DW❑ DISHWASHER R.O..0 ROOM RE{:�U,REMENTSOF THE CODES OFNEW DWG.❑ DRAWING SCHED.0 ROUGH OPENING 1 AXIS NUMBER DESK STATE. NOT RESPONSIBLE FOR YOR IGN OR CONSTRUCTON ERRORS RETAIN STORM ATER Rtl'�OFI= E.1.F.S.❑ EXTERIOR INSULATED FINISH SYS EIaEC:T.0 CENTERLINE AXIS DES SCHEDULE PURSUANT TO CHAPTER 236 ELEC.❑ ELECTRICAL SHT'.❑ SECTION �t ELEV.0 ELEVATION SIM..❑ SHEET ®G U 9�C� Q + .. OF THE TOWN OU EQ.0 EQUAL SPEFC.❑ SIMILAR ��V EXIST.❑ EXISTING SQ.L❑ SPECIFICATIONS USE IS UIVI_E�WFU F.D.0 FLOOR DRAIN S.S.I❑ SQUARE WITHOUT CERTIFICATE FIN.[] FINISH STD).❑ STAINLESS STEEL (fir{ �p FLOUR.❑ FLOURESCENT STL..❑ STANDARD OF 0i�VV1 'uy =i) FLR.❑ FLOOR STO)R.❑ STEEL LEGEND fal Ems^'•"► "1r'k° �cin FLSG.❑ FLASHING STReUC.LI STORAGE �r+�..��,+ 1 FOUN.❑ FOUNDATION SUS>P.0 STRUCTURAL rpleced or Tr,,vjcS pLACARDING RE( lJIRED ��t FT.❑ FEET, FOOT SW.U SUSPENDED \/� \\j\\ EARTH ^� � }�•��++ TU SWITCH GA.0 GAUGE TEL..❑ TREAD CONCRETE }� Mt n C ebrIS GALV.0 GALVANIZED T&GU TELEPHONE a= : 1 1'QV I .t�RrI. t G.C.0 GENERAL CONTRACTOR T.O. TONGUE AND GROOVE gla i g oC� 1� K,2PIOI" ❑ G.W.B.❑ GYPSUM WALL BOARD T.O.C.❑ TOP OF glazing on buildings as per GRAVEL H.B.0 HOSE BIB T.O.,S.❑ TOP OF CONCRETE w 1"��ray A' HDWRG HARDWARE T.O.'.W.❑ TOP OF STEEL HEM.[] HEMLOCK TYP'.❑ TOP OF WALL STEEL 025 y_/z;2/ HORIZ.❑ HORIZONTAL T.P.I❑ TYPICAL 1 PERMIT SET 05MAY N0. ISSUANCE DATAT E H.M.❑ HEAT MIRROR VERZT.❑ TOILET PAPER DISPENSER M, 7 RELEASES H.V.A.C.0 HEATING VENTILATION&AIR CONE ITW.NIING VERTICAL BATT INSULATION I.D.0 INSIDE DIAMETER /Ul WASHER _ SEAL: IN.❑ INCH, INCHES W.C:.❑ WITH RIGID INSULATION INSUL.0 INSULATION, INSULATED WD..❑ WATER CLOSET L L: y INT.❑ INTERIOR W.HI.❑ WOOD Q��POp,M C Vp�O y�.A LAM.0 LAMINATED WINID.0 WATER HEATER GYPSUM WALLBOARD LAV.❑ LAVATORY W.\AV.M.❑ WINDOW LB. POUND W/O)❑ WELDED WIRE MESH * J L.F.❑ LINEAR FOOT X❑ WITHOUT MASONRY E � w : 2'1 Q'E' LVR.❑ Li LOUVER YD.LU INDICATES TIMES OR BY ❑ �32421 MAX. MAXIMUM YARD BLOCKING �F N MECH.0 MECHANICAL ® FRAMING MEMBERS MFR.❑ MANUFACTURER PLYWOOD GENERAL NOTES: ® LAMINATED VENEER LUMBER 1.)ANY ERRORS, OMMISSIONS, OR CONFLICTS FOUND IN ANY PART OF THESE CONSTRUCTION DOCUMENTS 0 FINISHED WOOD JJJJJJJJJ SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. 2.)WRITTEN DIMENSIONS ALWAYS TAKE PRECEDEINCE OVER SCALE. DO NOT SCALE THE DRAWINGS. 3.)ALL CONSTRUCTION SHALL COMPLY WITH THE LATEST EDITION UNIFORM BUILDING CODE AS ADOPTED AND ANY OTHER LOCAL, STATE AND NATIONAL CODES, ORDINANCES AND REQUIREMENTS GOVERNING THIS CONSTRUCTION. 4.)VERIFY BOTH EXISTING AND FINISH GRADES WITH THE DRAWINGS. 5.)VERIFY ALL BUILDING LOCATIONS AND CONC. PAD ELEVATIONS WITH THE DRAWINGS PRIOR TO PROCEEDING. 6.)VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE BEFORE PROCEEDING. VERIFY ALL FIELD DIMENSIONS OF EXISTING CONDITIONS. 7.)ALL DIMENSIONS AND NOTES SHOWN ON ONE PORTION OF A DRAWING SHALL APPLY TYPICALLY TO ALL OPPOSITE HAND OR SIMILAR CONITIONS UNLESS OTHERWISE NOTED. 8.) DETAILS SHOWN ARE TYPICAL. SIMILAR DETAILS APPLY IN SIMILAR CONDITIONS UNLESS OTHERWISE NOTED. PROJECT: 9.)ALL DIMENSIONS ARE TO FACE OF FRAMING UNILESS OTHERWISE NOTED. 10.)VERIFY ALL ARCHITECTURAL DETAILS WITH THIE STRUCTURAL REQUIREMENTS BEFORE THE ORDERING Motto-Kalich Residence OF OR INSTALLATION OF ANY ITEMS. 11.)SKYLIGHT LOCATION AS SHOWN ON THE FLOOR PLANS SHALL BE CENTERED IN THE SPACE UNLESS OTHERWISE NOTED. ALL LIGHT FIXTURES ARE SHO)WN ON THE ELECTRICAL PLANS. 12.)VERIFY ALL PRODUCT DIMENSIONS WITH THE MAANUFACTURER FOR PROPER FIT AND INSTALLATION. Mattituck, NY DRAWING NAME: * SPACE IS UNCONDITIONED SHED COVER SHEET DRAWING NUMBER: DRAWN BY: AC\T SET: CHECKED BY: ACV A SCALE: 1/4"=1t-0" SHEET: CURRENT 0 * 1 ISSUE DATE: 11-10-2006 dul 1 Division #I : General Requirements: Division #4: Carpentry/Wood/Steel: Division #4: (continued) Division #8: (continued)I Division #13: HVAC: q The following General Notes shall apply to all sections and divisions of the Rough Carpentry/Wood: 5 Screws: Self drilllinc1, corrosion resistant, philhps head I" for base layer; I SPACE IS UNCONDITIONED I 0 All finish carpentry shall be top duality workmanship. All work shall be true, 5/8" for second layer wilier( shown on drawings, electrically driven. max ARCHITECT Specfications, to the Working Drawings and to the entire project. I All framing shall be done in accordance with the latest edition of"National level, and smooth and shall be made ready for finishing work. All nails and spacing 24"o.c. 528 SOUTH HARBOR ROAD SOUTHOLD, NY 631 806 2537 1 The contractor shall furnish all labor-, materials, equipment and services Design Specfication for Stress Graded Lumber and Its Fastening" as published screws shall be countersunk and plugged. All corners shall be mitered. necessary and required to complete all work described in and implied by by the National Lumber Manf. Asso. G Metal trim/corner bEeadS/,Jay beads/etc. similar to 200 series, manf. by these specifications and Working Drawings. Division #5: Roofing: US Gypsum. Install at all interior corners and as recommended by manf. 2 All lumber materials used In the building shall be good, sound, dry material 2 In order not to delay the work, the contractor shall ordler all specfICed free from rot, large and loose knots, shakes, and other imperfections whereby Roof Shingles: 7 All drywall walls and ceilings identified as painted shall have a level 4 finish. materials and fabricated Items with sufficient lead time as to ensure the proper the strength may be impaired and of sizes indicated on the drawings. Joint taping and nailholcd spackling materials as manf. by US Gypsum. Provide sequencing of the work. I Roofing: Shall match the existing roofing material. Install per manufacturers on all,Joints, all internal angels and casing bead trim. 3 All work and workmanship including nailing, blocking, bridging, etc shall recommendations. Submit actual sample of roofing for Owners approval. 3 The standards indicated shall apply to the work except when applicable conform to State / Local Code Requirements. 8 Sound retardant (noon frying) caulking shall be clear silicone as manf. by governing codes or regulations are more restricted, in whiich case such codes 2 Ridge Vents: Install Ridge Vents by Cor-A-Vent or approved equal/ low General Electric. and regulations shall govern the work.. 4 Provide Ledger, Blocking, Nailers and Rough Framing hardware as required. profile/cover vent#V-400/c5 or approved equal. Also provide as indicated gable end vents. 9 Installation: 4 In general, manf. recommendations5 and installation Instriuctions shall be 5 Unless other wise noted, all lumber for roof and floor,Jolsts and other a) Installation shall mot be started until windows are glazed and doors are followed for all materials used in this project. structural members shall be Douglas Fir Larch No. 2 or better with min. Roof Flashing/Gutters/ Leaders: Installed unless openings are temporarily closed. Inside temp to be above 50 FB-1500psi and E-I .7 psi and shall bear visible grade stamp. degreesF. Ventilated. 5 Checking and Scaling Drawings: The contractor shall verify all dimensions I Roof flashing, including all hips and valleys, shall be aluminum Coll flashing. shown on the working drawings and will be responsible for the correctness of G All beams,,Joists and rafters to be set with natural crown up. All work shall be inaccordance with the roofing manufacturers b) Gypsum board sffiali be fastened in horizontal position securely to studs the setting of the work'. The contractor shall not set work by scaling the recommendations. with screws specified. Place boards with min amount of Joints. Where free drawings. he will follow dimensions rather than scale. All dimensions shown 7 Provide double- Joists and headers around all roof openings and parallel ends occur between stcuds, etc. back blocking shall be Installed. to be "verified" or "confirmed" shall be verified in the field. walls unless otherwise noted on plans and details. 3 Roof gutter drains shall match CX51tincl. c) Drywall construction with defects of such characters that will mar the G All work shall be maccordance with all applicable building codes and 8 Unless otherwise noted provide a (3) 2x 10 minimum header where rough 4 All required leaders from gutters as shown on plans shall be 4" alum. and appearance of finished work, or which 15 otherwise defective, will be rejected regulations of the governing town and state. The contractor shall not do any opening does not exceed 3'-0". shall be attached to building face with appropriate copper fasteners. Leaders and shall be removed aind replaces at no expense to the owner. work which IS in violation of these codes. shall have cleanouts and be attached to dry well system and or pipe to daylite. 9 Plywood subfloor shall be 4"T*G. Apply common sense when sizing Match existing typical gutter and leader system. 7 The working drawings and specifications are to be considered as fasteners for Truss and I-Joist systems, and select a fastener to grab as cooperative. Any work showen in the drawings, but not described in the much flange as possible. DO NOT size a nail or screw that will Division #G: Building Insulation/Sealants/ Flashing: Division #10: Painting ,and Finishing: specifications, or visa-versa, or any work within the limits of the drawings and penetrate the bottom side of the flange. The naihng pattern shall follow the 5pec1flcat1on5, Is to be considered as part of the contract and shall be APA (American Panel Association) recommends a 12" inside, G" edges pattern. I Building Insulation: Shall be a "Falsh and Batt" system. Glass Fiber Batt General executed by the contractor. Insulation, as manufactuered by Johns-Manville or approved equal. 4" thick in 10 Material used for wall and roof sheathing (where required) shall be APA walls (R I I), 8" thick in roof(R25), Provide sound Insulation batts between all I All colors shall be as, selected by the owner. Samples for all colors, paints, 8 The contractor shall be responsible for debris removal. reated sheathing 5/8". Index stamp shall be-visible on all sheets. All edges second fioor,Jolsts. All exterior wall cavities and roofs provide 2" spray and finishes shall be prepared by the contractor for the owners approval. All shall be supported on 2x blocking. Nail material at G"o.c. at panel edges and applied "Icyene" open cell Insulation as per manufacturers recommendations At trim to have a gloss finiish. All walls and ceihngs to have a flat finish. 9 The contractor shall be responsible for all the methods and means of 12" o.c. at intermediate supports; with GD nails, allow 1/8" spacing at panel cathedral spaces provide ventilation baffle fabricated from 3/4" rigid insulation Construction necessary and requiredl for carrying out the work. ends and 114" spacing at panel edges. All work shall conform to the board (foil faced each side. 2 All painting and fimsNnine shall be performed and all surfaces prepared for recommendations of the American Plywood Association. painting and finishing in strict accordance with manf. recommendations and 10 The contractor shall provide and execute all shorings, jackings, bracings, 2 Vapor Barrier: All interior spaces shall be sealed on the inside face of specifications. All new surfaces and altered existing surfaces shall be properly etc. required to accomplish the work:. The contractor shall be responsible for I I Unless otherwise noted, J015t hangers, framing anchors, rafter anchors, framing members with a kraft paper vapor barrier as manufacturered with batt prepared to receive th(e finish. the design and execution of these Items. and cross bridging shall be minimum 1(5 gauge prime galvanized steel as Insulation. manufactured by TECO, Simpson, or approved equal. Special nails as supplied 3 The following Is a licit of approved manf.: I Pratt and Lambert, 2 Pittsburgh by manufacturer shall be used for required nailing. Sealants: Paints, 3 Sherwin Wilhaims, 4 Benjamin Moore, 5 Cabot's Stain, G Cuprinol. Division #2: Sitework/ Excavation/Septic System/ Utiht)y Connections: 12 Provide "x" bridging or solid blocking 8'-0" minimum o.c. bottom ends of I One part silicone sealant, in color as selected by owner, at all exterior 4 All paint, pigments, ods, etc. shall be of"first line quality", requiring no Site Work: bridging shall not be nailed until after subfloors and partitions above are frames in contact with cement, plaster, concrete, wood, etc. and at,Joints addition of thinners or other vehicles, and shall be delivered to the site in constructed. and locations noted on drawings. manf. sealed and labele.,d containers. All products shall be oil based unless I Landscaping: The contractor shall do those things indiccated on the plans otherwise noted. and necessary to the carrying out of the construction worrk. he shall protect 13 Wood plates and sill in contact with concrete foundation walls and 2 Filler: Filler material shall be closed cell, compressible, resilient, free from from damage those Items which might be harmed by his wcork. All plantings concrete slabs shall be pressure treated. tar, asphalt, oil, or other foreign substances. Filler shall be approved 5 Hardware, hardware. accessories, machined surfaces, plates, lighting close to the construction will be protected from damage. Provide and spread expanded polyethylene form in rod shape. fixtures and similar terms in contact with painted surfaces and not to be grass seed in disturbed areas and areas indicated on the Site Plan. 14 All pressure treated wood shall be "ACQ"or approved equal. painted, shall be removied, masked or protected prior to surface preparation 3 Caulking primer shall be non staining primer as recommended by the caulking and painting operations. 2 Site Preparation: The contractor shall organize the storing of materials/ 15 All,Joists, beams, trusses, or rafters, which are flush framed, shall be compound manuf. tools/ etc and the placement of debris containers in an ourderly and neat connected with approved type galvanized metal,Joists or beam hangers. Interior Plnlshingy manner as approved by the Owner. The "work areas" shalll be kept clean and Flashing: neat at the end of the work day. I G Provide a minimum of two studs at end of all beams and headers if no I Walls and Ceilings: All gypsum wallboard surfaces shall be painted: one posts are specified on Structural Plans. I All building flashing indicated and required shall be aluminum coil flashing. prime coat/two finish (coats. 3 Staking and Layout: Before starting the new work, the contractor shall stakeout the new work and investigate the foundation coniditions. He shall 17 Inflitration Barrier (Membrane): Provide and Install Henry Blueskin SA at all 2 For other flashing and waterproofing materials see details. 2 Wood: Unless othClr Wse noted, all wood surfaces shall be painted: one verify final locations and conditions with the Owner and thie Architect before exterior walls and as per manufacturers 5pe01ficati01`15. prime coat/two finish (coats. Cabinetry to be field painted shall be primed by proceeding. 3 The contractor shall provide pan flashing and counterflashing at all cabinetry subcontractor and finish painted in field: finish with 2 coats. 18 All bolts shall be made from steel which satisfies the requirements of penetrations of roof and exterior walls at windows and door heads and at Excavation and Grading: A5TM-A307-8GA "Standard 5pecificaton for Carbon Steel Bolts and Studs, door 51115 and at all other areas Indicated and required by good construction. 1 PERMIT SET 05 MAY2025 GO,OOOp51 tensile strength". Bolts shall be inserted in holes with a diameter No. ISSUANCE DATE I Investigate foundation conditions of construction, to sere if they meet I/I G" larger then the bolt diameter. The end dl�,ance, edge distance, and 4 Elastomeric Flashing: Provide and Install Elastomeric Flashing as manuf. by assumed conditions. spacing of bolts shall be as shown in the details. WR Grace and Co or approved equal @ Roof Eaves as indicated and all valley RELEASES roof Intersections for a min of 3'-0" coverage each side of break. 2 Excavate for foundations as required by plans, details, ,and job conditions. 10 All lag screws shall be made from steel which Satisfies the requirements of SEAL: All footings shall rest on undisturbed soil, a minimum of 4'-'-O" below grade. ASTM A307-8GA. Lag screws shall be inserted In lead holes as follows: I . Provide all labor and materials as per details. The lead hole for the shank shall have the same nameter and depth of Division #7: Exterior Windows and Doors/ Interior Doors: \�,�EREID q/�C penetration as the shank., 2. The lead hole for t'ne threaded portion shall Q�(� OPM C. Vp�O'Sj� 3 Provide New Underground Footing and Basement Draims as indicated on have a diameter equal to 112 the shank diameter and a depth equal to the I All windows and doors shall be Andersen 400 Series. Installed per Drawings and/or required by code. Provide Site Drainage/Dry Wells/ Etc. as length of the threaded portion. manufactures recommendations. P �' indicated. C� 20 See Typical Wall Details and Specifications and other Details for other 2 Contractor shall confirm and check all PO Saes, Frame Sizes, etc. prior to 4 Provide for all temporary Utilities, Water, Electrical, Telephone, Cable TV, requirements and materials. ordermcJ. t `' Well Line, etc. as required. N � 3 Interior and Exterior Wood Trim/Casing Trim/ Extension Jambs/51115/etc. p32427 5 Grading: Backfill and grade around foundations and s1a�b work as required shall be supplied and Installed by the contractor as required. Profiles/ Details Q� byjob conditions and as indicated en Plans. Foundation backfill shall be 4 All fabrication and erection of structural steel shall satisfy the "Spec for to match existing submit samples for Architect approved. NEW placed, compacted, and puddled in layers 12 inches deelp. design, fabrication and erection of structural steel for buildings" and the "Code of standard practice for steel bulldings and bridges" by the American Institute 4 The contractor shall supply and install all Interior Doors as per plans. The G Strip topsoil from areas to be excavated, stock pile close by, and reinstall of Steel Construction. contractor shall supply and Install all hardware as selected. Hinges shall be on top of all disturbed, filled and backfilled areas at the eend of construction. included. All interior doors shall be as Manf by Simpson, architect shall Finish Carpentry: approve prior to ordering. Provide cut * spec for approval. 7 Furnish and spread approved fill a15 required by backfilhvng. I See plans, and details for other work and materials. 5 The contractor shall provide rough openings/casing trim/stone saddles/ 8 Septic System: N/A 5/4",Jam125, etc as required. All doors shall be painted. 3 Exterior Trim: Trim pieces, as indicated, shall be Versa Tex (or equal PVC 9 Well/Water: N/A trim) and match the ew5ting material in dimension and profiles as indicated/ DIV15ion #8: Interior Finlshes: inferred by drawings and as approved by Owner/Architect approved. 10 Utility Connections: The contractor shall provide all labor and materials I All Gypsum Drywall work shall conform strictly to the standards of the required to provide the necessary Utility Services. The contractor shall 4 Interior Floors: TBD Gypsum Drywall Construction handbook by US Gypsum Company. contact all necessary people and companies, coordinate :services and work, and obtain all necessary permits and approvals. All work shall be done as per 5 Interior Wood Trim: All interior trim, including window trim, door trim, 2 All Drywall products shall be as manf. by US Gypsum Co. code and regulations. Provide load calulations as require:d and prepare baseboards, etc. shall be milled from solid poplar, select clear grade. All detailed expansion, if required, report. crown style trim to be MDF. All profiles and details to match existing and 3 Gypsum Board: "Imperial Gypsum Sheetrock" with tapered edges, 5/8" submitted for approval by Architect. thick(both walls and ceilings). Finlshed surface to be skim coated. Follow Division #3: Masonry U.S.G. Specifications and recommendations. Plaster shall be painted. Concrete and Foundations: 4 Gypsum Board at bath and lavatories shall be the moisture resistant type, with impregnated face paper. Treat cut surfaces of moisture resistant board I See Structural Plans, Notes, and other Details, for Corncrete Slabs, Slab as recommended by the manf. Or use 5/8"Wonder Board. Pitching, and other foundations and structural conditions.. 2 Concrete: No concrete shall be poured subject to fre;ezinci conditions or on frozen ground. All footings shall be formed to meet seizes indicated on Motto-Kahch Residence drawings and details and should rest on undisturbed soil//a minimum of 3'-G" below grade. Twenty-eight days comprehensive strengths for concrete shall be as follows: Footings 3000p51, Slab on Grade 4000p51, 'Walls 3000p51. New Slab areas on grade shall be 4" thick stone concrete withi WWF GxG W 1 .4 X 1 .4 over G" 314" gravel bed. Provide G mil Polyethylene Wapor Barrier under slab. Slab shall be finished in accordance with ACI Standdards 3 18,304,anci 310. All reinforcing bars shall be billet steel conforming to A51TM AG 15, grade GO. Ties and stirrups must be grade 40. All welded wire meth (WWF) shall conform to ASTM A 185. All vertical surfaces of coneretee shall be formed for walls. Mattituck, NY Reinforcing steel shall be placed to provide the following minimum concrete cover: Slab on Grade 1 112", Walls 2", Footings 3". The contractor shall verify all drawings for coordination between trades and prrovlde and or install anchors, inserts, sleeves, hangers, etc. required for varrious trades. DRAWING NAME: 3 Provide damproofing at foundation walls and slabs/as per details and per SHED code. SPECIFICATIONS DRAWING NUMBER: DRAWN BY: ACC' SET: CHECKED BY: ACC' A SCALE: 1/4"=1'-0" SHEET:CURRENT0 *2 ISSUE DATE: 11-10-2006 NAILING SCHEDULEdul I v �y Joint Description Nail Sizes Nail Spacing �� . ARCHITECT ROOF FRAMING Rafter to Top Plate(Toe-nailed) 3-8d per rafter 528 SOUTH HARBOR ROAD SOUTHOLD, NY 631 806 2537 Ceiling Joist to Top Plate(Toe-nailed) 3-8d per joist Ceiling Joist to Parallel Rafter(Face-nailed) 3-16d each lap Ceiling Joist Laps over Partitions(Face-nailed) 4- 16d each lap SIMPSON LSTA — 20 GAGE RIDGE STRAP — ALL ROOF RAFTERS Collar Tie to Rafter(Face-nailed) 2-8d per tie Blocking to Rafter(Toe-nailed) 2-8d each end Rim Board to Rafter(End-nailed) 2- 16d each end WALL FRAMING Top Plate to Top Plate(Face-nailed) 2- 16d' per foot ICE SHIELD UNDERLAYMENT REWIRED Top Plates at Intersections(Face-nailed) 4-16d joints-each side Stud to Stud (Face-nailed) 2- 16d 24"o.c. 16d 16"o.c. along edges Header to Header(Face-nailed) 'o URRICANE CLIP TYP. -N Top or Bottom Plate to Stud (End-nailed) 2- 16d per 2x4 stud 2- 16d per 2x6 stud 2- 16d per 2x8 stud ALTERNATE POSITION OF HURRICANE CLIP. Bottom Plate to Floor Joist,Bandjoist,Endjoist or Blocking (Face-nailed) 2- 16d' per foot USE SIMPSON H3 FLOOR FRAMING Joist to Sill , Top Plate or Girder(Toe-nailed) 4-8d per joist Bridging to Joist(Toe-nailed) 2-8d each end Blocking to Joist(Toe-nailed) 2-8d each end SIMPSON H2 HURRICANE CLIP UST37 METAL STRAP Blocking to Sill or Top Plate(Toe-nailed) 3- 16d each block NAILED FROM RAFTER TO STUD. ROVIDE 8d COMMON NAILS @ @JACK POST Ledger Strip to Beam (Face-nailed) 3- 16d each joist TYPICAL ALL RAFTERS. (5) 8d 4" O.C. AT EXTERIOR EDGE OF W/(4) 8d NAILS @ 48" Joist on Ledger to Beam(Toe-nailed) 3-8d per joist Band Joist to Joist(End-nailed) 3-16d per joist NAILS EACH END. ALL SHEATHING EACH END TYP. Band Joist to Sill or Top Plate(Toe-nailed) 2- 16d' per foot APA RATED PLYWOOD TP EXTEND TO TOP OF TOP PLATE ROOF SHEATHING (4) Sd NAILS TYP. Structural Panels 8d 4"o.c. perimeter zone JACK POST. other 6"o.c. edges of MST27 @ STUDS panel, 12"o.c. interior W/ (4) 8d NAILS of panel @ 48" O.C. EACH END TYP. FLOOR JOIST CEILING SHEATHING Gypsum Wallboard 5d 7"edge/10"field DOUBLE TOP PLATE \\—PLYWOOD SHEATHING TO COVER LAP BOX BEAM — TOP AND BOTTOM HEADER WALL SHEATHING 2 X 6 @ 16" O.C. STUDS IMPSON MST27 Structural Panels 8d (see table 3.9) 1 1/2" WIDE — 20 GAGE Fiberboard Panels METAL STRAP @ 48" O.C. 7/ 16" 6d 3"edge/6"field MAXIMUM. 25/32" 8d 3"edge/6"field STRAP Gypsum Wallboard 5d 7"edge/10"field W/ (4) 8d NAILS Hardboard 8d (see table 3.9) O OF Particleboard Panels 8d (see table 3.9) SIMPSON MST27 1 1/2" WIDE FFOPUNDATION Diagonal Board Sheathing WRAP & NAIL STRAP „ 4 4d NAILS — 20 GAGE METAL STRAP @ 48 O.C. 1 PERMIT SET 05 MAY 2025 p pp + 12" FROM EACH CORNER WRAP' NO. ISSUANCE DATE 1"x 6"or 1"x 8" 2-8d per support ( I P E. DE 4 ISd L:::: 1"x 10"or wider 3-8d per support AROUND SILL PLATE �� f�; AT ANCHOR BOLT BdLN ?'4'"" "PL�TE:" ( ) RELEASES FLOOR SHEATHING Structural Panels (2) # 5 REBAR , Dp ° D ° D .Op • ° ° p p,p,p ♦ p ° pD�° p °. D ,p pD p p D p D Op , D D p D ° • p ° pD^. °. D ° DD SEAL: 1"or less 8d 6"edge/12"field D D X 6 SILL PLATE D p O p ° '. , D ° p Da DD'p D D o p '. ° 0 D♦ p ° p p p , p '1p D D D p D • D D p 0 D D D p D D p p D p ♦ D p ° , D O D ° D D 9 • D D ° •p .p D D p D D D D ♦V p D p , D p D ° D p p °D D D V °D D ° D D D p p a D D ° ° °D <° D ° °D p p DDD ° °p D D p • D greater than 1" 9 ' D ° , D ° D D p ...p p , D p p ACQ TREATED. o p a D p p 10d E edge 6' field ° D D p °' ♦ D ° ' ° p . ' pD D D 0 D �` EFIEo q�,c p o . D p D D D D • D ° ° D D D D D p • D p p' 'DD p '.D D ° p •'D ° p D p p D, D ° p p ° D p D D p a D ° p p p o,, 0 p D p p D, p ° D ^ D p p 0 a D p D D p D ° D p p .p p ^ D ..D ° V. D ° D D ° D D D D ��C. 1 - Diagonal Board Sheathing ° D p p, D ° pDD D• D p DD • D D p V ° ° pDOD p ° D. ° D . D ° D.°DD • f D D p C , D O O(('�� SEE FOUNDATION DWG. I. .DD p p .p V D ° p 1"x 6"or 1"x 8" 2-8d per support ° ° ppff 1f " O.C. D p D V D ° D p V. p D D D D D p • D p p a p ° D D p D D /O X 12 A.B. @ 48 C p p DD D p p D • D D p 0' • D. p D p D .p Dp D D D'° p ' D p D. p ° ,'D p pD 1"x 10"or wider 3-8d per support FOR DESIGN D D • W/ FENDER WASHER. ° ° °D D DD° D ° D p D D D D D p • °D'p D °D • D C D ° • D D D D O • p ° D D D D D p p 0 p ° D pD p, ° pD D p Da.p p pp C D D p p pD p D p ° D , D ° .pDD DaD ♦ D ° ° D °Dp • DD ODDpppD• D 0 DDDp VD<pDp DDDD •pp p D ° p ° p • D .� pD DD °, D ° pDD p° Da Dp ° ° DD , D D ° ♦ p p D D D • D D D D °DD a D D• D ° ° OD p D•.DD ° p °DD a D .� D°pD ° p°` D ° D°Dp p °•'po ° p'DDD a D V pDV p pDp • D .D ODDp p D°♦ pD ° 'pp 1 0 p p ° p Nailing requirements are based on wall sheathing nailed 6i"on-center at the panel edge. If wall sheathing is nailed DD ° '°p° D ° D D p D p DD ° D' `< .D p ° °pD ' ° D ° ;°• D DODDp ° DD ° DD •V D D ° ' ° N 3"on-center at the panel edge to obtain higher shear capacities, nailing requirements for structural members shall °` ° DDp p p ODD •pp D op °p DD" ° V D°p D ° DD ° D DD p 0 PD ° ° °D po DDDD •pp DD♦ Dp P DpDDD p Da Dp Dp.° °D DD'•p ° DDp ° °DDD• °p D .D °DD ° p°•.Dp ° ° °DDD ° D• DDD° ° poD°•0 D D°° p °°pD, DO 0 ^A- be doubled , or alternate connectors,, such as shear plates, shall be used to maintain the load path. 9� �32421 P� Da D ° DP p p D , D p pDD ° Da VD'p D Dp • D D D ° p p'.o ' DD p D° D ° °•,.DD ° ppD ° Da pD V p °` • p D p ° D p.0 ` O �^ 2 When wall sheathing is continuous over connected membters,the tabulated number of nails shall be permitted to F NEW be reduced to 1 - 16d nail per foot. SECTION DIAGRAM ELEVATION DIAGRAM DESIGN CRITERIA: GROUND SNOW LOAD-45 PSF. WEATHERING-SEVERE HOLD DOWN AND SHEAR CONNECTION CRITICAL PATH FIRST LEVEL -40 PSF. L.L. FROST LINE DEPTH -36" LIVING AREAS -40 PSF. L.L. TERMITE-MODERATE TO HEAVY BEDROOMS -30 PSF. L.L. DECAY-SLIGHT WIND SPEED - 130 MPH SEISMIC DESIGN CATEGORY- B ICE SHIELD UNDERLAYMENT REQUIRED-YES a a a a a ` a a PLYWOOD SHEATHING 2 X 6 STUD WALL STA15-20 GAUGE STRAP TO STUD METAL STRAP @48" O.C. W/ (4) 8d NAILS + 12" FROM EACH CORNER 0 0 WRAP AROUND SILL PLATE. USE WINDOWS - GLAZED OPENING h h 2 X 6 TREA (4) 8d NAILS INTO SILL PLATE. PROJECT: NAIL SHEATHING TO SILL FOR NEW CONSTRUCTION , EXTERIOR WINDOWS(MUST BE PROTECTED VIA GLAZING MEETING 0 < 10 0 PLATE USING 8d NAILS @ 4" O.C. THE LARGE MISSILE TEST CERTIFICATION OF ZONIE II ASTM E 1886-97 AND ASTM E 1996-99 1(0 0 0 < 30 0 (2) #5 REBAR CONTINUOUS Motto-Kalich Residence OR VIA STRUCTURAL SHUTTERS WITH ATTACHMENT HARDWARE PROVIDED. NEW STRUCTURES a a ° fRMITE SHIELD AND SILL SEAL. LOCATED WITHIN ONE(1) MILE OF THE MEAN HIGH WATER MUST HAVE GLAZING CONFORMING 5/8" DIA. x12" A.B. @48" TO WIND ZONE III, MISSILES DEFINED IN PARAGRAPHI 6 OF ASTM E 1996-99. GLAZING CONFORMING GABLE ROOFS HIP ROOFS EACH CORNER. W/ FENDER WASHER. O.C. — TYP. + .B. FROM GRADE 6" MIN. BELOW TO WIND ZONE II, MISSILES CAN BE USED AT A DISTANCE GREATER THAN ONE MILE OF THE COASTLINE. 0 10 0 PROVIDE 8d COMMON NA41LS @ 4" O.C. °o D p p TOP OF CONC. AT HIGH PRESSURE ZONIE. ° p D D D /�/�/�/� r�r�r /�/� D p °Dp • DD D p0..p,• D, ° DDD p , p \ \ \ \ %�iT�,�Y,�i,��i,��/,� �//\�//�� @ 6" O.C. AT ALL OTHER PORTIONS OF THE PROTECTIVE PANELS TO BE PROVIDED FOR ALL AREAS BY : ° ° ° ° ROOF TYP. D D ° D ♦ D ° °°DDa WATERPROOF ALL A-CLEAR SHIELD HURRICANE+ SECURITY PANELS -631 -287 5060 OR ° 1/2" EXPANSION SEAL •oDooQ , URFACES BELOW Z MattltuCk, NY B-QUICK GUARD STORM PANELS. 631 -287 5330 D ° GRADE (TYP.) p ° D D D OR D PER PLANS o C-PLYWOOD PANELS AS PER CODE 4 CONC. SLAB ff ° II I W/6X6 #10/#10 WWM D` DD ' ;,;° .p°< DRAWING NAME: D p D PROTECTION DEVICES TO BE IN ACCORDANCE WITH LARGE MISSILE TEST OF ° SHED ASTM E 1996 AND OF ASTM 1886. AS NOTED IN 201l5 International Residential Code. PROVIDE 8d NAILS @ 4" O.C. AT PERIWETER INTERIOR 2" X 4" KEYWAY ° D a 10 0 0 < 45 0 PORTIONS OF PANELS IN HIGH PRESSURE ZONES. D; • D a D , D a a p D p (2) 15 REBAR ° D♦ DD°° WIND DIAGRAMS NOTE : a = 4 FT. IN ALL CASES CONTINUOUS ° D` GABLE ROOFS X 16 PC. FTG. SET ON 10< 0 < 45 0 UNDISTURBED SOIL DRAWING NUMBER: SET 36" BELOW GRADE DRAWN BY: ACC' SET: NAILING DIAGRAM FOR COMPONENT AND CLADDING PRESSUIRE ZONES FOUNDATION SECTION DIAGRAM CHECKED BY: ACC' A SCALE: 1/4"=V-0" SHEET: CURRENT O . 3 ISSUE DATE: 11-10-2006 i Lot Zoning/Area ARCHITECT LOT AREA: 22,500 sf- 0.517 ACRES 528 SOUTH HARBOR ROAD SOUTHOLD, NY 631 806 2537 C�5-FERN CURRENT ZONING: R-40 30 co M COgpX Lot Coverage pRMER2y OF ' �/— `S� • l� pRF RPN �� � 2 Allowable: 0W MEy / � 1� �� � - PNpS N �``�NO � 22,500 X 20% - 4500 sf bL BPR�PR �� 22 � j� ��` �o Dwelling 1618 sf o O'�j0E �E 56 l.P 7 Deck 487 sf ^` �j �R F�NGEI EEC Porch 81 sf �HERS�°M 6� ,v� 2nd Floor Cantilever 24 sf 5\\.�FEN �i�� ��` ey° °oE �; on Covered Concrete 55 sf N`�5 Hot Tub 46 sf \\sH �� pRIVEWAy em Sub Total - Existing 2311 sf EX\SBA p MO ED � \ , ASPHA • �° U�p00R / , � �Y�PR°P R��� � �o A�PNK Q !" Ep °�� v �, Proposed Cabana 342 sf �pR���R�`l PROo0ER -; W P5H 1 �0 24 2 �' ----- Proposed Outdoor Shower 48 sf 0W 0R `v�p S \; 1 S�oRy �� ,J o Proposed Shed 555 sf P Np5 N pMp,S L\ p -o Sub Total 945 sf ``gyp PbL - pSEp -,--, 0 � �,,o O o Proposed Pool 1243 sf S 18 N\G\A - ;" PR 'pp� rn n O 0 \ pWAU 787a �,o y N Total Coverage 4499sf Aq QROp � �00 SN\ o m� • \ Gross Floor Area Calc —41 --==-r ED N EEP 0 Pg o\P. `�D w � 5' EXEC � � Allowable: Z \ oR E HAM M��ER ` ` V ERHEAD UPI RES ONE MON 'S 3,350 + 250 = 3600 sf o GAS C C . E l 15- Q°°\ NE��I00�1 �IERN�PID First Floor Area 1618 sf t-Q6N°C°oS 00 / _o� O s / go / �\�\,�y Qp��R Second Floor Area 853 sf v CM 0 E� 'o 2 13'Xa� POO` 00 / I Total Gross Floor Area 2471 sf � O O 2 a FN CIE; � 5 PERM T SET 05 MAY 2025 Drainage Calculations 4 PROGRESS SET 02 MARCH 2O25 2 PROGRESS SET 02 FEBRUARY 2025 / 1 CLIENT REVIEW 24 JANUARY 2025 897 S.F. X 0.166 = 148 C.F. N0. ISSUANCE DATE � S Vol 2 Total Required = 148 C.F RELEASES O , 3oOO��jO �� 1 - 8' Dia. X 6' Deep drywell provided = 265 C.F. SQL. EDi AR p 3, NC. 0 , ' S Ps:))• �5� c.voc cti F % N o 4, C 66 oP� 0 j032421 OF NEW N 5� �P R� \I P EC PROJECT: SITE PLAN SCALE: V=16' Motto-Kalich Residence HEAVY DUTY CAST IRON FRAME&COVER TO GRADE 6"$LAB FOR NON-TRAFFIC BEARING 8"SLAB FOR TRAFFIC BEARING GEOTEXTILE APPROVED OUTLET PIPE AS REQ'D M *** }}i. C7.lLL FABRIC APPROVEDINLETPIPE O ❑ MIN.I'DIA.PITCHED}'PER FOOT l,UCk, NY WOOD OR METAL SUPPORT POSTYS MIN 4'DIA.PITCHED PER FOOT FLOW DIRECTION EXIST EXCAVATED& BACKFILLED GRADE DRAWING NAME: TRENCH SITE PLAN 1 Vd 4 _ = N 5 15 35 75 4' DIA. BACKFILL W/CLEAN SAND&GRAVEL DRAWING NUMBER: DRAWN BY: SET: SILT FENCE DETAIL D)RYWELL DETAIL CHECKED BY: A 2 . 3. SCALE: 1/161f=11-0" SHEET: PROJECT No 1 1 �.�.,,•F I:; sy„ "Ara' t'z A)dul I I ARCHITECT 528 SOUTH HARBOR ROAD SOUTHOLD, NY 631 806 2537 I I I I I I 221-3" 01 11 22'13" ol I I — — — — — — — — — — — — — I — — — — — — — ——— — — — — I �n � I I I I I I i 51/2" 21}-4" 1 2" 1 " R 5 1i/2" 6 „ C @ 6 20' 11 All I 14"T11 5 0 SERIES @ 16' O.C. I I I 1 4"X 14 LVL LEDGER BD -CONT. SHED 4" P.C. SLAO ON GRADE I I 4" P.C. SLA ON GRAIDE W/6x6 Wl A4 VV1.4 WWM I ( EW-I V\ 6x6 W1.4I VV1.4 VVV'VM PULL DOWN STAIR i w I m N I I N I I r\j LU I I I , N TOP OF FIN SHED FLOOR I I N _j ELEV:60'-0" I I I I J I I I IIIIIIIIIIII IIII I I� IIIII Iji �Ii X co 5 ( PERMIT 4 PROGRESS SET 02 MARCH 2025 3 PROGR SS SET 27 FEBRUARY 20258" P.C.FOUNDATION LL TOP OF F SSHED FLOOR 2 PROGRESSSET 02 FEBRUARY 2025 W/ 245 REBAR TOP WALL 1 CLIENT REVIEW 24 JANUARY 2025ELEV:60.0' NO. ISSUANCE DATE 8"x16" P.C. I I FOOTING W RELEASES BA345 RERj DROP WALL III I I m j ifl SEAL: Ln- - - - - - - - - - - - - - - - - - - -- - - - � I 21 ,. 12"LVL I I N EREDAR — — — — — — — — — — — — — — — — — — — — — — — — — — — — ra IL -----_(2)jAC.K POST&-------------------- ------ L (2)JACK POST&------ --j 4'-3" 01 4'-3" (3) KING POSTS (3) KING POSTS 22' 3" 22'-3" 09 032427 Q� rF OF IN I I I FOUNDATION PLAN 1 FLOOR PLAN ROOF PLAN 1 . SCALE: 1/4"=1'-0" 1 . SCALE: 1/4"=V-0" 2 . SCALE:1l4"=V-0" ASSEMBLY/PARTITION TAGS: EW-I 2"X6" STUDS @ 16" O.C. W/ R21 BATT INSULATION W/ e" APA RATED PROJECT: PLYWOOD SHEATHING EXT & 2" AC GRADE PAINTED PLYWOOD INTERIOR Motto-Kahch Residence SCHEDULED ITEM TAGS: 07 WS-01 WOOD SIDING 01: I"X4" T&G VERTICAL SIDING OVER BENJAMIN OBDYKE RAINSLICKER OVER HENRY BLUESKIN 07 WD-01 WOOD TRIM 01: Mattituck, NY SOLID PVC TRIM VERSATEX OR EQUAL SIZE AS NOTED ON DRAWINGS 07 RF-01 ROOFING 01: DRAWING NAME: GAF TIMBERLINE - COLOR TBD ASPHALT SHINGLE ROOFING OVER SHED e" APA RATED CDX PLYWOOD , t Jr PLANS 09 WB-01 WALLBOARD 01: 112" APA RATED AC PLYWOOD 09 WB-02 WALLBOARD 02: 112" GYPSUM WALL BOARD LEVEL 4 FINISH DRAWING NUMBER: DRAWN BY: SET: fl9 P-01 PAINT 01: A I COAT OF PRIMER-BENJAMIN MOORE CHECKED BY: A 2 COATS OF PAINT-BENJAMIN MOORE SCALE: 1/4"=1'-0" SHEET: PROJECT No 2 • 1 I ld ARCHITECT 528 SOUTH HARBOR ROAD SOUTHOLD, NY 631 806 2537 I ASSEMBLY/PARTITION TAGS: EW_1 2"X6" STUDS @ 16" O.C. W/ R21 BATT INSULATION 07 RF-01 W/ 5" APA RATED PLYWOOD SHEATHING EXT & 2" AC GRADE PAINTED PLYWOOD INTERIOR s" 4 4 SCHEDULED ITEM TAGS: 07 WS-01 07 WD-01 El 07 WD-01 4 Q7 WD-01 ALUM.GUTTER 07 WS-01 WOOD SIDING 01: LEADER I"X4" T&G VERTICAL SIDING OVER BENJAMIN OBDYKE RAINSLICKER OVER HENRY BLUESKIN I 5 07 WD-01 WOOD TRIM 01: 07 WS-01 SOLID PVC TRIM VERSATEX OR EQUAL 4 SIZE AS NOTED ON DRAWINGS 8-WIDE 7' HIGH OVERHEAD GARAGE DOOR 07 RF-01 ROOFING 01: GAF TIMBERLINE - COLOR TBD 2\ ASPHALT SHINGLE ROOFING OVER g" APA RATED CDX PLYWOOD 09 WB-01 WALLBOARD 01: 1/2" APA RATED AC PLYWOOD 09 WB-02 WALLBOARD 02: 112" GYPSUM WALL BOARD LEVEL 4 FINISH - - - - - - - - - - - - - - - - - - - - - - - - - -_ —f� — -- - - - - - - - - - - - - - - - - - - - - - - - - - - -_ � J 09 P-01 PAINT 01: I COAT OF PRIMER-BENJAMIN MOORE 2 COATS OF PAINT-BENJAMIN MOORE 5 PERMIT SET 05 MAY 2025 4 PROGRESS SET 02 MARCH 2O25 3 PROGRESS SET 27 FEBRUARY 2025 I 2 PROGRESS SET 02 FEBRUARY 2025 1 CLIENT REVIEW 24 JANUARY 2025 NO. ISSUANCE DATE RELEASES SOUTH ELEVATION EAST ELEVATION SEAL: 2. SCALE: 1/4"=V-0" SCALE: 1/4"=l'-0" 54% E. N C. ogcy� � �3242Z OF NEW 07 RF-01 2 _ 07 WD-01 A 10—SM LO 07 WD-09 1 4 - ALUM.GUTTER LEADER IQ-2W � 07 WS-01 PROJECT: Motto-Kahch Residence Mattituck NY_ _ _ _ _ _ _ _ _ _ _ _ _ I _ _ I DRAWING NAME: i SHED ELEVATIONS 4 NORTH ELEVATION WEST ELEVATION SCALE: 1/4"=l'-0" 5 ., SCALE: 1l4"=l'-0" DRAWING NUMBER: DRAWN BY: SET: CHECKED BY: A SCALE: 1�4"=1'-n" SHEET: PROJECT No 391 �I Qf*rl7%' ARCHITECT 528 SOUTH HARBOR ROAD SOUTHOLD, NY 631 806 2537 I I i ASSEMBLY/PARTITION TAGS: 07 RF-01 I 2"X6" STUDS @ 16" 0.C. EW-1 12 W/ R2 INSULATION APA RATED rn 6F I PLYWOOD SHEATHING EXT & 4"PLYWOOD OVER 2" AC GRADE PAINTED PLYWOOD INTERIOR rw ® 14"-560 TJIs @ 16"O.C. o SCHEDULED ITEM TAGS: N 2 3 I HURRICANE 07 WS 01 WOOD SIDING 01: 1 4'X14" LVL LEDGER CONT. "CLIPS" 09 WB-01 I"X4" T&G VERTICAL SIDING ATTACH W/(2)TIMBERLOCK OVER BENJAMIN OBDYKE RAINSLICKER q SCREWS @ 16"OC SIMPSON HGU3.63-SDS HANGER I OVER HENRY BLUESKIN m W/WEB STIFFNERS WOOD TRIM 01: EXIST.GRADE 00 7 1/4' 07 WD-01 EW-I SOLID PVC TRIM VERSATEX OR EQUAL 3/4" 4" PLYWOOD SIZE AS NOTED ON DRAWINGS 62 _ ROOFING -r - _ _ - - I 07 RF-01 GAF TIMBERLINEMBERLINE - COLOR TBD TOP OF FINISHED FLOOR - _ - - - _ _ _ 60 SIDING OVER ASPHALT SHINGLE ROOFING OVER ELEV:60.0' g APA RATED CDX PLYWOOD BENJAMIN OBDKE s ' SLICKER CLASSIC RAINSCREEN �o 09 WB-01 WALLBOARD 01: 5„PLYWOOD SHEATHING 112" APA RATED AC PLYWOOD _ I 09 WB-02 WALLBOARD 02: EW 1 S 112" GYPSUM WALL BOARD (( LEVEL 4 FINISH I 09 P-01 PAINT 01: I COAT OF PRIMER-BENJAMIN MOORE 5 PERMIT SET 05 MAY 2025 2 COATS OF PAINT-BENJAMIN MOORE 4 PROGRESS SET 02 MARCH 2O25 q"X14" LVL LEDGER-CONT. s PROGRESS SET 27 FEBRUARY 2025 ATTACH W/(2)TIMBERLOCK 2 PROGRESS SET 02 FEBRUARY 2025 1 CLIENTREVIEW 24 JANUARY 2025 SCREWS @ 16"OC CROSS SECTION � SIMPSON HGU3.63-SDS HANGER NO. ISSUANCE DATE W/WEB STIFFNERS RELEASES 1 . SCALE: 1/4"=V-0" SEAL: ED ARC, t 4P 03242� y�Q� Z'ANCHOR BOLTS OF NE`N 32"O.C.& 12" 4" P.C. SLAB ON GRADE FROM EACH CORNER d W/6x6 W1.4xW1.4 VWVM 8" P.C.FOUNDATION ° 40 6"SAND WALL W/245 REBARS ° d °° ° d 74 ° ° \ ° ° d ° ° d ° d ° // �� \ \ \ \ \ ° °° X\ PROJECT: ° \\ N \\ \\ ° ° ° Motto-Kalich Residence \ \\ \\ \\ \ a 4,4 \\ \\ \\ x /Z 2"X4" KEYWAY d \ • °: ° ° d • X Matdtuck, NY 00 ° ° ° ° ° ° DRAWING NAME: V-4" WX16" P.C.FOOTING SHED W/3#5 REBAR BUILD-ING SECTIONS WALL SECTIONS DRAWING NUMBER: 2 . LON4 _ GITUDNAL SECTION WALL SECTION- DRAWN BY: SET: SCALE. 1 1/2 1 O CHECKED BY: A SCALE: 1/4"==1'-0" SHEET: PROJECT No 302