HomeMy WebLinkAbout52865-Z '60f SOUryolo Town of Southold * P.O. Box 1179 �0 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 47290 Date: 08/14/2026 THIS CERTIFIES that the building SINGLE FAMILY DWELLING-ADDITION AND ALTERATION Location of Property: 1855 Greenwav E Orient, NY 11957 Sec/Block/Lot: 15.4-10 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 03/31/2026 Pursuant to which Building Permit No. 52865 and dated: 04/15/2026 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Rear covered porch addition to an existing single-family dwelling as applied for. The certificate is issued to: John Parisi ,Barbara Parisi Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: PLUMBERS CERTIFICATION: lutho - d Signatur �aofsooryO TOWN OF SOUTHOLD BUILDING DEPARTMENT N Y • e SOUTHOLD, NY ' VOUM BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52865 Date: 04/15/2026 Permission is hereby granted to: John P Parisi 48 Windsor Rd Rye Brook, NY 10573 To: construct additions and alterations to an existing single-family dwelling as applied for. Premises Located at: 1855 Greenway E, Orient, NY 11957 SCTM# 15.4-10 Pursuant to application dated 03/31/2026 and approved by the Building'lnspector. To expire on 04/14/2028. Contractors: Required Inspections: Fees: Single Family Dwelling- Addition &Alteration $271.00 CO-JRESINTIAL $100.00 Total 371.00 ----- ---- -------------- uildinglnspector ` / SAS OF So(/l�o TOWN OF SOUTHOLD BUILDING DEPT. `yco 631-765-1802 INSPECTION . [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] IN96LATIOWCAULKING [ ]. FRAMING-/STRAPPING [ FINAL .e , [ ] FIREPLACE.& CHIMNEY [ ] 'FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ], FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL �tIASk*� AJ '0/ cv :4REMARKS: �,�GUl n�c� DATE INSPECTOR FIELD INSPECTION REPORT I DATE COMMENTS FOUNDATION (IST) ------------------------------------ C FOUNDATION (2ND) P. z y ROUGH FRAMING& M PLUMBING SO r INSULATION PER N.Y. .6 H STATE ENERGY CODE tr •r •aG s a.s FINAL ADDITIONAL COMMENTS �5v O S m x � k 1 H �1 O o� z x H x C .b y S�fFoc,t TOWN OF SOUTHOLD—BUILDING DEPARTMENT y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 oy�ol ��4t Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownn .gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. Building Inspector: MAR 3 1 2026 Applications and forms must be filled out in their entirety.Incomplete ; applications.will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date:3/30/26 OWNER(S)OF PROPERTY: Name:Johnathan Parisi SCTM # 1000-15-01-10 Project Ad dress: 1855 Greenway East, Orient Phone#:646-36676618_ Email:john parisi@nm.com Mailing Address: 1855 Greenway East, Orient CONTACT PERSON: Name: Brooke Epperson Mailing.Add ress:PO Box 152, Mattituck, NY 11952 Phone#:631 603 9092 Email:bepperson@amparchitect.com DESIGN PROFESSIONAL INFORMATION: Name:Anthony Portillo Mailing Address:PO Box 152, Mattituck, N.Y. 11952 Phone#:631 603 9092 Email:aportillo@amparchitect.com CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ®Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $25,000 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ®No 1 PROPERTY INFORMATION Existing use of property: Intended use of property: n � Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to O this property? ❑Yes No IF YES, PROVIDE A COPY.Lq Check Box After Reading: The owner/contractor/design professional is responsible for all.drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable-Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name):& �Q �Y� (uthorized Agent ❑Owner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTYOF Sty-'FGLK ) -{ —W R) being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the (Contractor,Agent, Corporate Officer, etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of 20f it No ary Public ``.ZATEp.�� ;'r NOTARY ` ;'; " Notary Public,State of New Yorl; PROPERTY OWNER AUTHORIZATION' Luc 1* No,,�.�o�pio�xs2so r -Z QltaMW to SUM Cotatty (Where the applicant is not the owner) " " 'Yo��;`.�� Co,�tonEV nws residing at do hereby authorize �L� c�E t�N� to apply on my behalf to the T wn of Southold Building Department for approval as described herein. iff. ��` ner's Signature Date )O�V-Xca�� !oK=:Sl. Print Owner's Name 2 , U v ka S.C.T.M. NO. DISTRICT. 1000 SECTION: 15 BLOCK: 1 LOT(S): 10 0 If I If NORTH SEA DRIVE I WELL J #R-24-0688 VACANT I 15O DWELLING ILL LOT 43 WNVELL WATER IN FRONT YARD W N OVER 150' X e• DWELLING r WNVELL WATER r 0.9'E u~i N 89°32'10"E 132.00' SIX CL 159 CESSPOOL IN REAR OVER 150' - r n' EL 18.5 EL 18.6 1 EL 18.4 EL 17.3 r m r _ X 12.S PROPPED Z LL 150'NO SEPTIC DRYMU o I 1 �4��� i QO `_ 8'x5'DEEP / rn V a o 0 sns♦ ��• �, Na r EL 16.7 � m C11EL 18.6 m .8 a� .Z.I O(17.5) (17.0) I DWELLING 24.0' W VELL WATER �� a CESSPOOL IN REAR CONCRETE WASHOUTAREA I 15.D' GARAGE R INSMOFMOPOSEODRIVEWAY. CL14.7 OVER 150' PROPOSED DRAIEWAY ^ WELL WOOD ao' a.o' s 41.D' t 1 EL 18.3 POOL:.. STOOP N1855 o FOUNDATION EL 16.5 LOCATION DRY WELL 1 AUG.21.2024 ui LOT 44 8'x5'DEEP I TOP FND EL 17.8 of DWELLING .\� Oi �66 I WNVELL WATER 1N FRONT YARD OVER 150' 32.0' E N. 53.0' (16.55) L PANELANDAIRPUMP J (17.0) CELLAR ENT. I ELEC. ERVICET000NIROLPANEL EL 18.0 I / EL 17.0 � ELECTRICAND AI PPLYHOSETO OWiS I / F EL 15.0 / T SCH40 PVC VENTPIPE\F. I �/ (2�'IDx8'DEEPL.P�� SM78.5) C 1/ snc • � CLt3.5 LP a� \ F\ CD ZONED R-40 NON CONFORMING LOT Ca yiy OP a F o U.P. FRONT YARD: 40' MIN F I / SIDE YARD: 15' MIN. 35' TOTAL Be!g � i REAR YARD: So, MIN ¢]CP \ \ EL PIPES 0.5'S EL17.5 ���` EL15.7 EL14.\ REBAR GROSS FLOOR AREA 3,350 S.F. + (107x1780) = 3528 S.F. MAX. FENCE 1. S 89032'10"W - 132.00'_ _ U_P._ o.WE i 162, THE WATER SUPPLY, WELLS, DRYWELLS AND CESSPOOL LOT45 cL1zs I F DWELLING LOCAAONS SHO ARE FROM RELD OBSERVA77ONS AND OR DATA OBTAINED FROM OTHERS. S DWELLING O LP wNVELLwATER WELL WIWELL WATER O CESSPOOL IN REAR AREA: 21,780.00 SQ.FT.or 0.50 ACRES ELEVANON DATUM: NAVD88 OVER 150' I LP DWELLING_,,. OVER 150' UNAWHORRZED AL7ERA710N OR ADDIAON TO THIS SURVEY IS A WOLA77ON OF SEC71ON 7209 OF THE NEW YORK STATE EDUC47ION LAW. COPIES OF 7HIS SURVEY T• .._ wNVELL WATER MAP NOT BEARING 7HE LAND SURVEYORS EMBOSSED SEAL SHALL NOT BE CONSIDERED 7D BE A VAUD TRUE COPY. GUARANTEES INDIC47ED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED AND ON HIS BEHALF 70 7HE 777LE COMPANY, GOVERNMENTAL AGENCY AND LENDING INS177UT70N LP I WELL LIS70 HEREON, AND TO 7HE ASSIGNEES OF 7HE LENDING INS7U77ON, GUARANTEES ARE NOT 7RANSFERABLE D MC[20V THE OFFSETS OR DIMENSIONS SHOWN HEREON FROM 7HE PROPERTY LINES TO 7HE STRUCTURES ARE FOR A SPEGFIC PURPOSE AND USE 7HEREFORE 7HEY ARENOT INMNDSD TO MONUMENT 7HE PROPERTY LINES OR TO GUIDE THE EREC770M OF FENCES, ADDIRONAL STRUCTURES OR AND OTHER IMPROVEMENTS EASEMENTS D AND/OR SUBSURFACE"STRUCTURES RECORDED OR UNRECORDED ARE NOT GUARAN7F W UNLESS PHYMCALLY EVIDENT ON 7HE PREMISES AT THE 77ME OF SURVEY SURVEY OR LOT44 CERTIFIED TO: BURTDORFMAN; MAP OF:GREEN ACRES J A U G 2 2 2024 FILED:APRIL 13,1962 No.3540 s7TuATED AT ORIENT I TowN onsouTHotD BUILDING DEFT. SUFFOLK COUNTY, NEW YORK NTH M WOYCHi7K LAND SURVEl'IIdG, PLLC ' Professional Land Surveying and Design FND.LOCATION 08-21-24 TOE 7F$QU'THOI P.O. Box 153 Aquebogue, New York 11931 REVISED 05-31-24 FILE 0 224-43 SC@1"=30' DAIE:APRIL5,2024 N. USG NO. 050882 AL PHONE (83L)288-1888 FAX(631) 288-1585 5,?-S6 S 71 wee i ` 51TE PLAN HATCH KEY: PROPOSED BUILDING ADDITION Pad PROPOSED ACCESSORY STRUCTURE "` p 0- ® (FILED SEPARATELY) APP 0 ED AS NOTED ' {= a a DAB B.P.;# '�`' PROPOSED 2ND STORY Lu �. W ' W Cu FEE BY J M CV NCITIFYBUILDING DEPARTMENT AT OCI � ��C�l� � Q •-a-' 63'I 765-1802 8AM TO 41PM FOR THE C Lo FOLLOWING INSPECTIONS: 7.' I �,.,, 1. FOUNDATION-TWQREQUIRED ■ 1 � M �� '� r' +� t II��/ - r- FOR POURED CONCRETE J "I ^ .., a, = .' ;� ; ► ,: ; u w'.\r, � ''°; ,•::'''y „ � �"��cy►ma . -t '# % .� yq � +� �' co y 0 'le '4 t`• n r.. `i' . Y°.K'x r.s 2. ROUGH-FRAMINGI&PLUMBING t�i�i CER o i l��" � O C O 3. INSULATION ,:. :�':' ,. j *_. . #, :4 � , r�' ,s.: �F a L c cc �Y - 4. FINAL CONSTRUCTION MUST t „'. ° >) 0 . •. ,. PROJECT LOCATION &SCOPE ca d- + �!-e 4 ` r, 4. *& -e'r.�. T. '2<.. s R3 .s x N �. �'' > ,, ";; - �� '"- '� SITE PLAN & ZONING DATA O BE COMPLETE FOR C.O. rF IWL CONSTRUCTION ;�. �. i'. ?� a�y � p SMALL MEET THE '` ' + ;. °��t `"s? ,,� k, } r }¢° , 5 i m�:Y, ,� •.�r ,{ ,x .� ,� '. p m REQUIREMENTS OFTHE CODES OF NEW a,,:g j "=� r�,�e. >, , :,� �F �... 1 ��F �•.�±� ��a�+ A 4_ y'y'4.� a , N +� LO YORK STATE NOT RESPONSIBLE FOR ' �' "�� :�' ' ,� ``: „' '�. :� ' '�``�'�, co O a O DESIGN OR CONSTRUC'TON ERRORS y` SUBJE07 PROPERTY --�` 't`--=�` v y y Psp,, '1 w a° .` '-A ,, ' ,� 5�' r t r ` ? - Q" * . /s: fir. �:� , It GENERAL NOTES 'r ¢ - l , ►. � C-7 002.00 RETAIN ATE '.. .. � �r ,�-,.�� -�, .•�'-,�.. -�'�"`' ,":��y�,�. ,r' .. STORM WATER RUNOFF r . - t '�', �r ''Y.. ^ .'*' r �" " . ..•_ ;. �� "`;s ENERGY TABLE ANT TO e� �,z,+ '* '�'':�` Al t �... CHAPTER 236 ;. _; �� �* > ; wx ' . . �.. � ... .. STRUCTURAL DESIGN CHARTS COMPLY W ALL CODES N '� 1NEW Y WITH OF OF THE TOW CODE. ._ �`#t ,36 �f /^� ORK STATE&TOWN CODES /'►S R� � �= !:.s � * � .� r ���j �.-,f:�e4,; '{i.:¢'g°{tr�� ', .�4'''r� � �'�`'• :fir \.. �'.' ,./r�i: 'f'++':✓l� REQUIRED BOND NDITIONS 0� �t- I O .00 PROP. DEMOLITION ELEVATION TOV's",1ZB�, Y�� '; ^ F � * k . ;� EV TION x � ,. ,� . , ,.ti ;d; ;, , ,, f�` _ , , . ;"" ` PROP. DEMOLITION PLANS &OUTS! �D WAN PLMI ",�'3 BOARD `fib `�� .��'.`� �;�' � ; S •�f,.,. \ �. ' �"�,. :a�.� .: < .{;\ ;'. * c +� '. .., ,.w. �. PROP. ELEVATION & PLANS ..�J ... I, .31 0111.NTRUSTEES ► � , *;�� ` ,; < �- .: -* , ,t� ; , DEC p LEC�'RIC/"l �. � .,l x ; :r � s�f. f. I .00 S3' „OIDMu lNSI'7:;Cn0PW REQUIRED •, � ,� ` ,x . .q; ; `:, , ,4° z �,��, >", ., �� � PROP. BUILDING SECTION nn 11 ` ' " DESIGN DETAILS W �u I li i�.�..5 �i�:��\lT�i `0.�umfl��1\'f�„�i�• till exterior lighting LOC ATION MAP SCALE: N75 �j- I � •00 PROP. STRUCTURAL PLANS + Installed,replaced or N Q R T }-} 5 E A D R I � repaired shall conform DWELLING w/ WELL HATER repaired Chapter 172 (WELL OVER 150 FROM P - 7 SHARED PROPERTY LINE) I of the Torm COCK ,^ VACANT LOT W EL.=Ia.5' ° 132.00' EL. N5Q1 5210E _ X I o - DEMOLITION OF EX I ST 1 NC REAR WOOD 5700fi EXIST. WELL-----O N - PROPOSED REAR WOOD COVERED FORGH 4 ENTRY o _ I5' 510E YARC�) 57-75AGi< o - NOTE: PROPOSED POOL HOUSE FILED SEPARATELY AND 15 z I < I ° NOT FART OF TH 15 APPL I GAT 1 ON � I � N I FRO�E� I �A7A : J, EXIST. vi _ ./ BURIED J �PROP� GENERATOR W I�~-TANKANE J � I PROJECT / ZONINC DATA 1� EXIST. POOL. ���L�N� \��i TAX MAP # 1000-015-01-10 EQUIPMENT ZONING DISTRICT R-40 NC MI N• I �/ LOT AREA 0.5 ACRES CONTRPROP. BURIED i CofO - MAIN DWELLING PORCH, REPAIR EXIS TO _---ELEC_LINE_ #464225 ; 08/11/25 REPAIR 'EXISTING I I L--- -- � I DECK, OUT. SHWR., � GARAGE PATIO AS NECESSARY j EXIST. ND. I i EXIST. �� GofO -POOL #46424 ; FOR NEW PORCH I STOOP TO BE I OUTDOOR EXIST. BLUESTONE OS/IQ/25 FOOTINGS I DF-MOL15HED I SHOWER / DRIVEWAY w/ BELO. BLOCK CURB I SUFFOLK COUNTY HD APPROVAL R-26-052-7 6 BEDS EXIST. O IN-GROUND < Z DWELLING w/ WELL 1^IATER 0 POOL I Z (WELL OVER 150' FROM I I tea I 41.0' -' LOT COVERAGEtu o SHARED PROPERTY LINE) I d I TEST v I X I HOLE SOUTHOLD TOWN GODS 280-4 4 280-124 I J� , O ju O 0 EXIST. 2-5TORY v EL.=16.5 ( n/ DESCRIPTION (FOOTPRINT) AREA GOVERASE X 5.0' HD. FR. DWELLINS W BASEMENT B O 0 48.8' OARASE w/ TOTAL LOT AREA 21,'780.00 S.F. PROP. REAR SLAB-ON-GRADE - COVERED ( EXIST.) PORCH 4 ENTRY (5 BEDROOMS) f EXIST.1 I EXISTINS MAIN DWELLING 1880 S.F. 8.69b I L.P. I F.F. EL.=18.5' - -�� EXISTINS COVERED PORCH 256 S.F. 1.2`?6 PROJECT: 50.0 PROP. RED OAR. SLAB EL.=I-15 (Y u EXISTING POOL 512 S.F. 2.4% PARISI I WATER SUPPLY LINE I PROPOSED POOL HOUSE EXIST. I I r------- -- w O bqb S.F. 5.230 ND. I I 5' MIN. PR P. EXIST. I COVERED PORCH FENCE I I _ BURL D BASEMENT __ PROPOSED REAR COVERED COVERED PORCH OA5 L NE ENTRY 70 S.F. 0.3gb PORCH $ ENTRY TOTAL AREA OF ALL STRUCTURES 5,414 S.F. 15.19 I !PROP. MAXIMUM LOT COVERAGE ALLOWED: 203b 1855 GREENWAY EAST PROP. BURIED PATIO'COVERED i 1 �G I ORIENT, NY 11957 STORMWATER I I I �'Pi LEADERS i I 1 ��`o fi ZONING REGULATIONS MAIN BUILDING I 01 j \`�c�< I SOUTHOLD TOWN CODE 2&0-124 DRAWING TITLE: PROJECT LOCATION & SCOPE POOL I I ___ _ �\\ `�HOUSE NOT PART J MAIN DWELLING CODE EXIST. PROP. COMPLIES SITE PLAN & ZONING DATA HOUSE NOT � -- � � � �OF THIS FILING EXIST. ELEC. �- ' 0�51 aE AR SETBA K METER ON J I M FRONT YARD 40.0' 41.0' 41.0' YES O H-FRAME �\ N. SIDE'YARD 15.0' 47.4' 4'7.4' YES � j O MIN COMBINED , PAGE: SID11 1 10 55.0 100.0 100.0 YES � EL.=14.0' � � YARD5 - - - � - MIN. i�EAR YARD � 50.0' 48.8' 50.0' YES G-001w00 EL.=1-1.5' S8<q°32'10"W EXIST. I DWELLING w/ WELL WATER UTILITY DATE: 03 30 26 DWELLING W WELL WATER (WELL OVER 150' FROM POLE 1 OF 5 (WELL OVER 150' FROM SHARED PROPERTY LINE) SHARED PROPERTY LINE) I 51TE LAYOUT NOTES: I. TH15 15 AN ARCHITECT'S SITE PLAN d 15 SUBJECT TO VERIFICATION BY A LICENSED SURVEYOR. THE INFORMATION 1u j... REPRESENTED ON THIS SITE PLAN IS TO THE ARCHITECT'S BEST OF KNOWLEDGE. I 2. SURVEY INFORMATION WAS OBTAINED FROM A SURVEY DATED APRIL 5, 2024, r `` MOST RECENTLY REVISED JUNE 15, 2025, '' AND PREPARED BY: J KENNETH M. WOYCHUK LAND 5URVEYINS Pq P.O. BOX 153 ` S I TE �L�I `� AC�UEBOOUE, NY I1a31 PHONE: (651) 2a15-1588 SCALE: I" = I5'-0" NOTES $ SPEC I F 10A71 ONS CARPENTRY WOOD FRAMING MATERIAL STANDARDS FOUNDATION, CONCRETE, AND MASONRY A 35RE Y I AT I O I S IT 15 THE CONTRACTOR'S RESPONSIBILITY TO KEEP THIS CONSTRUCTION D>OOUMENT BINDER I. ALL LUMBER SHALL BE DOUGLAS FIR LARCH #2 $ BETTER (Fb = 875) UNLESS THE PROVISIONS OF THI5 STANDARD ARE NOT INTENDED TO PREVENT THE USE I. CONTRACTORS TO VERIFY ALL DIMENSIONS OF EXISTING FOUNDATION AS IT TOGETHER AT ALL TIMES. IT IS ALSO THE CONTRACTOR'S RESPONSIBILITY TO READ ALL NOTES, OTHERWISE NOTED. OF ANY MATERIAL OR METHOD OF CONSTRUCTION NOT SPECIFICALLY APPLIES TO THE NEW WORK EBEING PERFORMED AND SHALL COORDINATE THE BD. BOARD INSUL. INSULATION SPECIFICATIONS,AND BE FAMILIARIZED 11IITH THE PLANS PRIOR TO WORK PRE5GRIBED HEREIN. WHEN IT CAN BE SHOWN, AND THE AUTHORITY HAVING 5UB-CONTRACTOR5 IN SUCH AMANNER TO ASSURE THAT THE CONDITIONS OF a 2. ALL LUMBER IN CRAWL SPACES TO BE IS ABOVE SCRATCH GOAT. MAINTAIN JURISDICTION FINDS BY EXPERIENCE, MODELING, OR TESTING BY AN APPROVED THE FIRST AND SECOND FLOORS ARE TAKEN INTO ACCOUNT. BFE BASE FLOOD ELEVATION INT. INTERIOR 5" MIN. FOUNDATION EXPOSURE. AGENCY, THAT A PRODUCT OR PROCEDURE PROVIDES EQUIVALENT OR Q GENERAL GREATER STRUCTURAL SAFETY OR DURABILITY, SUCH PRODUCT OR PROCEDURE 2. ALL FOOTINGS TO BEAR OIN FIRM,VIRGIN,UNDISTURBED 501L BLDG. BUILDING K KIPS (1000 L55) 0 I. NO WORK TO START UNTIL APPROVED PLANS ARE OBTAINED FROM THE 3. SILLS TO BE P.T. AND SECURELY FLASHED WITH A TERMITE SHIELD, AL50 SHALL BE DEEMED TO CONFORM TO THE REQUIREMENTS OF THI5 DOCUMENT W APPLICABLE BUILDING DEPARTMENT. PROVIDE SILL SEAL/INSULATION. SIZE OF SILL TO BE (2) 2"xb", UNLE55 (1) 2"xb" (THIS DOCUMENT 15 TO MEAN A REFERENCE TO THE CURRENT AMERIGAN WOOD 3. 501L TO HAVE MIN. BEARINI6 CAPACITY OF (1) TOW50. FT., U.O.N. BM BEAM MANU. SPEG.'s MANUFACTURER'S SPEGIFIGATIONS W co 2. ALL CONSTRUCTION SHALL BE PERFORMED IN A WORKMANI LIKE MANNER. I5 NECESSARY TO MATCH FLOOR HEIGHTS WITH THE EXISTING STRUCTURE. COUNCILS WOOD FRAME CONSTRUCTION MANUAL AND THI5 P5 FORMAT, A5 J APPLICABLE AS A DERIVED WORK). 4. FOOTINGS TO REST A MIN. OF 4'-0" BELOW GRADE, UNLE55 B.O. BOTTOM OF MAX. MAXIMUM (y) ALL DIMENSIONS, CONDITIONS, AND APPLICABLE INFORMATION OF EXISTING 4. AT FLUSH FRAMING USE 16 6AOE METAL JOISTS HANGERS BY "TE0011 OR OTHERWISE NOTED Q 4-+ (\j STRUCTURE/SITE SHALL BE FIELD VERIFIED BY GENERAL GOMTRAGTOR. EQUAL. I. IDENTIFICATION: ALL SOLID-SAWN LUMBER, GLUED LAMINATED TIMBER, BOT. BOTTOM MECH. MEGHANIGAL Ir •C Lo PREFABRICATED WOOD I-JOISTS, STRUCTURAL COMPOSITE LUMBER, 5. WALLS TO BE POURED CONICR.ETE OF SIZE SHOWN ON DRAWINGS, U.O.N. _ 0) 5. MINIMUM, DOUBLE HEADERS AND TRIMMERS AROUND ALL OPENIN05 IN PREFABRICATED WOOD TRUSSES, GYPSUM, HARDBOARD, AND STRUCTURAL B.O.W. BOTTOM OF WALL MIN. MINIMUM O 3. ALL WORK SHALL CONFORM TO NATIONAL, STATE, AND LO+GAL CODES FLOORS, ROOFS, AND WALLS. PANELS, SHALL CONFORM TO THE APPLICABLE STANDARDS OR GRADING, 6. NO BACK FILL SHALL BE PLACED AGAIN5T FOUNDATION WALLS `� O AND AUTHORITIES HAVING JURISDICTION. RULES SPECIFIED IN 1.1 THROUGH I.B. UNTIL 151 TIER OF FRAMING 15: IN PLACE. G.J. CEILING JOIST NAVD88 NORTH AMERIGAN VERTICAL DATUM OF Ig88 +� b. DOUBLE ALL JOISTS UNDER PARALLEL PARTITIONS, POSTS, AND BATH TUBS, i � � 4. ALL UNNOTED OR NON-VISIBLE EA5EMENT5 ARE THE RESPONSIBILITY U.O.N. I.I. LUMBER: ALL WOOD MEMBERS USED FOR LOAD-BEARING PURPOSES, 7. FOOTINGS TO BE POURED CONCRETE OF SIZE SHOWN ON DRAWIN65. O C (\j z O OF THE OWNER/BUILDER [COL. COLUMN NYC, BG NEW YORK CITY BUILDING CODE INCLUDING END-JOINTED AND EDGE-GLUED LUMBER, SHALL BE IDENTIFIED d '(D Lo --,e 5. ANY OMISSIONS OR DISCREPANCIES O'= PLANS AND/OR JOB CONDITIONS 7. ALL BEAMS, GIRDERS, ETC. TO HAVE MIN. OF 5-1/2" BEARING BY THE GRADEMARK OF A LUMBER GRADING OR INSPECTION AGENCY 8. ALL OPENINGS FOR BEAM IPOCKET5, UTILITIES, ETC. TO BE FILLED C r- U r- CONT. CONTINUOUS O.G. ON CENTER � SHALL BE CLARIFIED WITH THE ARCH ITEGT/ENGINEER BEFORE PROCEEDING WHICH PARTICIPATES IN AN ACCREDITATION PROGRAM, SUCH AS THE SOLID WITH CONCRETE. C G X = N WITH THE WORK. 5. MIN. HEADER TO BE (2) 2 xIO UNLESS OTHERWISE NOTED. AMERIGAN LUMBER STANDARDS COMMITTEE OR EQUIVALENT. THE O 4-+ GRADEMARK SHALL INCLUDE AN EASILY DISTINGUISHABLE MARK OR q. ANCHOR BOLTS SHALL BE IIN ACCORDANCE WITH PAGE 6-005. DEL. DOUBLE OGG. OCCUPANCY O m (9 g. ALL WOOD SILLS AND WOOD IN CONTACT WITH MASONRY/CONCRETE TO BE INSIGNIA OF THE GRADING AGENCY WHICH COMPLIES WITH THE 4-J 4✓ M� b. NO DEVIATIONS OR GRANGES TO THE STRUCTURAL 5Y5TEN�1 SHALL BE MADE P T REQUIREMENTS OF U.S. DEPARTMENT OF COMMERCE P520-qq. 10. ALL CONCRETE TO HAVE AN ULTIMATE COMPRESSIVE 5TRENGTH AT 28 DFZ DESIGN FLOOD ELEVATION O.H. OVERHANG c N p cc UNLE55 APPROVED BY THE ARCH 77ECT/EN5INEER.1. CONTRACTOR Q O d 6 DAYS OF 4,000 Ps.1., U.O.N. DIM. DIMENSION PBFE PRELIMINARY BASE FLOOD ELEVATIONI B 10. ALL EXTERIOR SHEATHING SHALL BE NAILED AS, PER FASTENING SCHEDULE 1.2. GLUED LAMINATED TIMBERS: GLUED LAMINATED TIMBERS SHALL MEET BEFORE THE START VERIFY DIMENSIONS OF FOUNDATION WIT+'H FLOOR PLANS T OF FRAMING ON PAGE 0-003. GENERALLY, SHEATHING IS OF I/2„ THICKNESS ON WALLS AND THE PROVISIONS OF AN51/ALTG A I q0.1 STRUCTURAL GLUED LAMINATED II. GONG. SLABS TO REST ON IMIN. OF 6 FINE GRAVEL OR SAND WITH D.J. DECK JOISTS P. GONG. POURED CONCRETE ROOF AND 15 OF GDX GRADE, UNLESS OTHERWISE NOTED. SEE FLOOR PLANS TIMBERS. 6 MIL. POLYETHYLENE VAPORZ BARRIER UNDER FOR ADDITIONAL NAILING OR DIFFERENT NAILING REOUIREMEN75 WHEN EA. EACH PL. PLATE 8. DRY WELLS AS REQUIRED BY STATE ��ND LOCAL CODES. APPLICABLE. 1.5. PREFABRICATED WOOD I-JOISTS: ASSEMBLIES U51NO PREFABRICATED 12. COPPER FLASH ALL JOINTS WHERE SLAB ABUTS FRAMING. g. DO NOT 50ALE DRAWINGS, WRITTEN DIMENSIONS TAKE PRECEDENCE WOOD I-JOISTS SHALL MEET THE PROVISIONS OF ASTM V5055 ELEV. ELEVATION PLYWD. PLYWOOD II. SUB FLOORING, GENERALLY, TO BE OF 5/4 THICKNESS AND OF GDX GRADE. STANDARD SPECIFICATION FOR ESTABLISHING AND MONITORING 15. BRICK VENEER TO BE ANCHORED WITH CORROSION RESISTANT TIES - 10. TIFICABUI, CE ARE RESPONSIBLE FOR ALL INSPECTIONS, APPROVALS, NAILING AS PER FASTENING SCHEDULE ON PAGE G-005 AND GLUED, U.O.N. STRUCTURAL CAPACITIES OF PREFABRICATED HOOD I-JOISTS, THIS (1) HALL TIE PER (5) 50. FT. EC�UIP. EQUIPMENT P.T. PRESSURE TREATED CERTIFICATES, CERT. OF OCCUPANCY OR. COMPLETION AND UJ.L. APPROVAL DOCUMENT, THE GOVERNING BUILDING CODE AND ANY ADDITIONAL 12. EXTERIOR SHEATHING TO BE COVERED WITH 'TYVEK' HOUSE WRAP OR REQUIREMENTS AS SET FORTH IN THE MANUFACTURER'S GORE 14. FLASH JOINT AT BRICK LEEVOE AND PROVIDE WEEP HOLES, EXIST. EXISTING REQ'D REQUIRED 11. THESE SET OF DRAWINGS ARE THE PROPERTY OF ANTHONI'( PORTILLO, RA APPROVED EQUAL. EVALUATION REPORT. MAX. 52'-0" O.G., TO DIRECT ,ANY CONDENSATION TO THE EXTERIOR. AND SHALL NOT BE ALTERED OR BE REPRODUCED WITHOUT WRRITTEN 15. BLOCK EXTERIOR STUD WALLS AT HALF STORY HEIGHTS AND AT 1.4. STRUCTURAL COMPOSITE LUMBER: SINGLE MEMBERS OR A55EMBLIE5 15. APPLY (1) GOAT OF TAR BASED WATERPROOFING TO EXTERIOR OF FOUND. EXT. EXTERIOR Ri RISER PERMISSION FROM THE ARCHITECT. UNSUPPORTED EDGE SEAMS OF EXTERIOR SHEATHING. U51NG STRUCTURAL COMPOSITE LUMBER SHALL MEET THE PROVISIONS OF FROM FOOTING TO 2" ABOVE: FIN15H GRADE. U ASTM D5456 STANDARD SPECIFICATION FOR FRESH EVALUATION OF F.A.I. AIR INTAKE RM. ROOM R THE ARCHITECT IS NOT RETAINED FOR: SUPERVISION OF THE WORK AND IS - 14. PROVIDE 'X' CROSS BRACING AT JOISTS, STUDS, AND RAFTERS WHEN SPANS STRUCTURAL COMPOSITE LUMBER PRODUCTS, THI5 DOCUMEN, THE I6. NO CONCRETE OR MASONRY WORK 15 TO BE PERFORMED IN TEMPERATURES rI \ RESPONSIBLE FOR DESIGN INTENT ONLY. EXCEED 5'-0" AND AT EVERY 8'-O". GOVERNING BUILDING CODE, AND ANY ADDITIONAL R:EQUIREMENT5 AS OF 40OF AND FALLING, UNLE5i5 APPROVED BY ARCHITEGT/ENOINEER. NO FAR FLOOR AREA RATIO R.R. ROOF RAFTER of m 15. THE CONTRACTOR SHALL OBTAIN CERTIFICATE OF OCCUPANCY. SET FORTH IN THE MANUFACTURER'S GORE EVALUATION REPORT. CONCRETE SHALL BE PLACEL7 ON FROZEN SURFACES. F.A.V. FRESH AIR VENT STL. STEEL "'� W 15. TOP PLATES TO BE DOUBLED AND LAPPED AT CORNERS, SEE ALSO PAGE 14. THE CONTRACTOR SHALL KEEP PREMISES REASONABLY CLEAN AT ALL 0-004. 1.5. PREFABRICATED WOOD TRUSSES: ASSEMBLIES USING PREFABRICATED 11. NO ADDITIVES SHALL BE IPLAGED IN CONCRETE UNLESS SPECIFIED BY FF � FINISHED FLOOR S.V. SMART VENT • TIMES. AT THE COMPLETION OF WORK, THE CONTRACTOR SHALL REMOVE ALL WOOD TRUSSES SHALL MEET THE PROVISIONS OF THIS DOCUMENT, THE ARCHITECT/ ENGINEER. RUBBISH, WASTE MATERIALS, TOOLS, ETC., GLEAN &LASS ANC�l LEAVE WORK 16. APPLY ALL GONDITION5 ADDRESSED IN FASTENING SCHEDULE A5 GOVERNING BUILDING GORE, AND ANY ADDITIONAL R.EQUIREMENT5 AS BROOM GLEAN. NECESSARY. SET FORTH IN AN51/TPI I NATIONAL DESIGN 5TANDARD FOR METAL PLATE I8. PROVIDE BITUMINOUS JOINIT5 BETWEEN SLABS AND FOUNDATION WALLS AND FF ELEV. FIR5T FLOOR ELEVATION TBD TO BE DETERMINED CONNECTED WOOD TRUSS CONSTRUCTION, THE TRUSS DESIGN DRAWINGS, WHERE EVER APPLICABLE. r l 15. THE CONTRACTOR SHALL CARRY WORKMAN'S COMPENSATION AND GENERAL 17. PROVIDE ALL NAILING AND STRAPPING ADDRESSED ON PAGE5 6-005. OR THE MANUFACTURER'S CODE EVALUATION REPORT. F.J. FLOOR .JOI5T5 TEMP GL. TEMPERED OLA55 `.J c LIABILITY INSURANCE. ALL SHALL COMPLY WITH STATE AND LOCAL CODES Iq. UNLESS OTHERWISE INDIGA:TED, ALL FOUNDATION FOOTINGS ARE TO BE A AND ORDINANCES. 15. AT WET WALL PARALLEL TO JOISTS FRAME DOUBLE J015T AS PER GORE. 1.6. 6YP5UM: GYPSUM MATERIAL USED IN A STRUCTURAL APPLICATION SHALL MIN. 10 DEEP PROJECTING 6 ON EACH SIDE OF THE FOUNDATION WALL. FOUND. FOUNDATION THK. THICK GENERALLY, SEPARATE DOUBLE J015T THE THICKNESS OF WALL ABOVE. SUB MEET THE PROVISIONS OF ASTM 056 SPECIFICATION FOR 6YP5UM PROVIDE TWO #4 DEFORMED BARS CONTINUOUS IN THE FOOTING. ALL 4" THICK 16. THE CONTRACTOR SHOULD FULLY GUARANTEE HIS WORK AND THE WORK OF FLOOR SHALL NEVER EXCEED A 16" SPAN. WALLBOARD,ASTM C37 SPECIFICATION FOR GYPSUM LATH, OR A5TM G7g CONCRETE SLABS TO HAVE 6ix6 10/10 WELDED WIRE REINFORCING. FRCS FLOOD RESISTANT CONSTRUCTION ELEVATION T.O.W. TOP OF WALL !^ THE SUB-CONTRACTORS FOR A PERIOD of AT LEAST ONE YEEAR AFTER SPECIFICATION FOR GYPSUM 5HEATHIN6 BOARD. v J COMPLETION OF PROJECT. Iq. AT ROUGH OPENINGS PROVIDE ALL APPLICABLE NAILING AND STRAPPING 20. FOR SECOND STORY ADL7ITIONS, EXIST. FOUNDATIONS ARE TO BE VERIFIED FR. FRAME Tr TREAD n 1 AS PER PAGE 6-005. 1.7. HARDBOARD: HARDBOARD USED IN A STRUCTURAL APPLICATION SHALL AS IN SOLID B SOUND GONDITTION WITH AN EXIST. FOOTING OF MIN. I6 WIDE x 5 VJ I'I. THE CONTRACTOR SHALL INDEMNIFY AND HOLD HARMLESS THE OWNER, MEET THE PROVISIONS OF AN51/AHA A135.4 BASIC HARDBOARD OF DEEP $ V-O" BELOW GRADE., FRPR. FIREPROOF TYP. TYPICAL Q ARCHITECT/ENGINEER, AND THEIR AGENTS AND EMPLOYEES FROM AND 20. "P.T." SPECIFIES PRE55URE PRE5ERVATIVELY TREATED LUMBER IN ANSI/AHA AL55.6 HARDBOARD 51DIN6. A6AIN5T ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES, INCCLUDIN& ACCORDANCE w/ AWPA 022;WHERE DRILLING AND/OR GUTTING OCCURS, FIELD FTC. FOOTING U.O.N. UNLESS OTHERWISE NOTED TREAT LUMBER w/ COPPER NAPTHENATE WHICH SHALL CONTAIN 2% COPPER 1.8 STRUCTURAL PANELS: MECHANICAL CONNECTIONS: ATTORNEYS FEES ARISING OUT OF OR RESULTING FROM THE PERFORMANCE OF METAL LUMBER REPEATED BRUSHING, DIPPING, HI SOAKING UNTIL THE WOOD „ GYP. BD. GYPSUM BOARD VERT. VERTICAL THE WORK PROVIDED THAT ANY SUCH CLAIM, DAMAGE, LO R OR EXPENSE (A) ABSORBS NO MORE. ALSO, FOR HARDWARE USED WITH P.T. LUMBER, Led. PLYWOOD: PLYWOOD USED IN STRUCTURAL APPLICATIONS SHALL I. ALL MECHANICAL G N AFF`ROVE SPECIFIED O SIMPSON MAY BE IS ATTRIBUTABLE TO BODILY INJURY, SICKNESS, DISEASE OR DEATH OR TO SUBSTITUTED WITH AN APPROVED EQUAL PRODUCT. INJURY TO OR DESTRUCTION OF TAN61BL!= PROPERTY (OTHERZ THAN THE WORK CONTRACTOR 15 TO INSTALL HARDWARE THAT 15 SPECIFIED BY P.T. LUMBER MEET THE PROVISIONS OF U.S. DEPARTMENT OF COMMERCE H.D. HOLD DOWN V.I.F. VERIFY IN FIELD ITSELF INGLUDIN6 THE LO55 OR USE RESULTING THEREFROM).. (B) IS CAUSED IN MANUFACTURER SUCH A5: HANGERS, NAILS, SCR.EW5, FLASHING, ANCHOR BOLTS, VOLUNTARY PRODUCT STANDARD I (PS 1) CONSTRUCTION AND 2. THE SUBSTITUTION SHALL MMEET ALL OF THE MINIMUM CRITERIA SPECIFIED WHOLE OR IN PART BY ANY NEGLIGENT ULT OR OMISSION ).. THE ETC. FOR LOCATIONS SUCH A5: LEDGER BD., SILL PLATE, DECK CONSTRUCTION, INDUSTRIAL PLYWOOD, U.S. DEPARTMENT OF COMMERCE VOLUNTARY BY "SIMPSON" MN SHAGTU'JRER. HDR HEADER w/ WITH CONTRACTOR,IN ANY BY ANY ANYONE DIRECTLY O INDIRECTLY ETC. ANY REFERENCES TO GGA ARE TO REPLACED WITH P.T. PRODUCT STANDARD 2 (P52) PERFORMANCE STANDARD FOR WOOD-BASED STRUCTURAL- USE PANELS, APPLICABLE GODS HNGR HANGER WD. WOOD EMPLOYED BY ANY OF THEM, OR ANYONE FOR WHOSE ACTS ANY OF THEM MAY 21. LVL (LAMINATED VENEER LUMBER) DENOTES EITHER OF THE FOLLOWING: EVALUATION REPORTS. 5. ALL LOADING CAPACITIES SHALL MATCH EXACTLY OR EXCEED VALUES BE LIABLE REOAROLE55 OF WHETHER OR NOT IT 15 CAUSED IN PART BY A A. WEYERHAEUSER TRUS J015T 2.OE MIGROLLAM LVL INDICATED IN "SIMPSON" PRODUCT LITERATURE. THERE MAY BE SEVERAL HOR. HORIZONTAL ZR ZONING RESOLUTION PARTY INDEMNIFIED HEREUNDER. B. OEOR6IA PACIFIC 2.OE G-P LAM LVL 1.5.2. ORIENTED-STRAND BOARD (055), WAFERBOARD ORIENTED-STRAND LOADING VALUES, CONTR.ACTOR SHALL CONTACT ARCHITECT IF ANY P5L (PARALLEL STRAND LUMBER) DENOTES: BOARD OR WAFERBOARD USED IN STRUCTURAL IONS SHALL MEET LOADING VALUES ARE LE'55 THAN WHAT 15 SPECIFIED BY "SIMPSON" BU ALL MATERIALS, ASSEMBLIES, AND METHOD of CONSTRUCTION INGLUDIN6 A. WEYERHAEU5ER TRU5 J015T 2.2E PARALLAM P5L THE PROVISIONS OF U.S. DEPARTMENT OF COMMERCE VOLUNTARY BUT NOT LIMITED TO FORM-WORK, :WORK, FRAMING, N,AILIN6, PLACING ALL TO BE INSTALLED AS PER MANU. SPEC.'S PRODUCT STANDARD 2 (P52) PERFORMANCE VOLUNTARY PRODUCT 4. ALL MECHANICAL CONNECTIONS SHALL BE HOT DIPPED GALVANIZED OF CONCRETE, ETC. ARE TO BE CAREFULLY SUPERVISED BY THE CONTRACTOR STANDARD FOR WOOD-BASED STRUCTURAL- USE PANELS OR /� '�/�' '�A LI SURE THEY ARE IN ACCORDANCE WITH THE DRAWINGS„ SPECIFICATIONS,DRATIONS, 22 I-JOIST FLOOR SYSTEMS SHALL BE IN ACCORDANCE WITH THE WOOD APPLICABLE GORE EVALUATION REPORTS. 5. INSTALLATION 5PECI ICEA SHALL ALWAYS BE CARRIED OUT AS PER INSULATION � FENESTRATION RE O U I RE I " I E I �l TS APPLICABLE CODES AND GOOD PRACTICE. DEVIATIONS FROM THE DRAWINGS FRAMING MATERIAL STANDARDS SECTION, THE GOVERNING BUILDING CODE, MANUFACTURER SPECIFIC/ATIONS OF THE PRODUCT BEING INSTALLED. AND SPECIFICATIONS OF WILL NOT BE PERMITTED WITHOUT WRITTEN AND ANY ADDITIONAL REQUIREMENTS SET FORTH IN THE MANUFACTURER'S 1.5.3. PARTICLE BOARD: PARTICLE BOARD USED IN STRUCTURAL AUTHORIZATION OF THE ARGHITEGT/ENGIIaEER. CODE EVALUATION REPORT. APPLICATIONS SHALL CONFORM TO ANSI A205.1 AND ANY 6. ALL FASTENING CRITERIA SHALL BE CARRIED OUT AS PER MANUFACTURER Iq. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY SHOP DRAWINGS REQUIREMENTS AS SET FORTH IN THE MANUFACTURER'S CODE SPECIFICATIONS OF THE PRODUCT BEING INSTALLED PROPOSED DESIGN GORE PRESCRIPTIVE VALUE NEEDED, UNLESS OTHERWISE SPECIFIED. ALL DIMENSIONS AND CONDITIONS N0 NOTCHES IN THE TOPE BOTTOM EDGE OF SOLID SAWN RAFTERS SHALL EVALUATION REPORT. 7. VARIATIONS IN GONNEGTO)R CONFIGURATION SHALL BE APPROVED BY COMPONENT GOMP'L I ES PERTAINING ARE TO BE FIELD VERIFIED. NOT GUT IN THE MIDDLE ONE-THIRD OF THE RAFTER SPAN. NOTCHES IN THE ARCHITECT VALUE CITATION (PER 2020 NYSEGGG) OUTERR OUT OF THE SPAN SHALL NOT EXCEED ONE-SIXTH OF THE ACTUAL 1.8.4. FIBERBOARD: FIBERBOARD USED IN STRUCTURAL APPLICATIONS 20. CONTRACTOR TO REMOVE 4 RELOCATE AS REQUIRED ALL EXISTING WORK RAFTER DEPTH. WHERE NOTCHES ARE MADE AT SUPPORTS THEY SHALL NOT SHALL MEET THE PROVISIONS OF ANSI/AHA AIg4.1 CELLULOSIC 8. ALL CONNECTORS SPECIFIED AS A "SIMPSON" TOP MOUNTED BEAM EXCEED ONE-FORTH THE ACTUAL RAFTER DEPTH. BORED HOLES ARE LIMITED FIBERBOARD OR ASTM C208 STANDARD SPECIFICATION FOR WHICH INTERFERES WITH NEW GONSTRUGT�ON IN A WORKMAN LIKE MANNER. HANGER SHALL BE ALLOWdED TO BE SUBSTITUTED WITH A TOP MOUNTED IN DIAMETER TO ONE-THIRD THE ACTUAL RAFTER DEPTH AND THE EDGE OF THE CELLULOSIC, FIBER IN5ULATIN6 BOARD. MAX. U-VALUE = 0.27 BEAM HANGER ONLY ALOFN6 WITH SPECIFICATIONS LISTED ABOVE. FENESTRATION U-VALUE U-VALUE = 0.25 21. ALL MATERIALS ARE TO BE INSTALLED AS PER MANUFAG:TURER'S HOLE SHALL NOT BE CLOSER THAN 2 INCHES TO THE TOP OR BOTTOM WOES. (VERTICAL FENESTRATION) AIR LEAKAGE = 0.50 GFM/5F MAX. AIR LEAKAGE = 0.50 GFM/5F YES SPECIFICATIONS, UNLE55 NOTED OTHERWISE. 1.5.5. STRUCTURAL PANEL 51DING STRUCTURAL PANEL 51DIN6 USED IN PER R402.5.3 Q TABLE R402.1.2 - CLIMATE ZONE 4 24. NOTCHES IN EITHER EDGE OF STUDS SHALL NOT BE LOCATED IN THE STRUCTURAL APPLICATIONS SHALL MEET THE REQUIREMENTS OF U.S. 22. PROVIDE FIREBLOCKING AS PER NE?4 YORK AGGE551511-11TY STANDARDS. MIDDLE ONE-THIRD OF THE STUD LENGTH. NOTCHES IN THE OUTER THIRDS OF DEPARTMENT OF COMMERCE VOLUNTARY PRODUCT STANDARD I ALTERATIONS INVOLVING BUILDING ENVELOPE THE STUD LENGTH SHALL NOT EXCEED 25% OF THE ACTUAL DEPTH. BORED (P5- 1), THE GOVERNING BUILDING CODE, AND ANY ADDITIONAL ASSEMBLIES SHALL NOT BE REQUIRED TO COMPLY 25. PLEASE NOTE THAT THESE PLANS ARE PROTECTED A6AIIN5T ANY HOLES SHALL NOT EXCEED 40% OF THE ACTUAL STUD DEPTH AND THE EDGE R:EOUIREMENTS AS SET FORTH IN APPLICABLE CODE EVALUATION WITH THE REQUIREMENTS FOR NEW CONSTRUCTION, UNAUTHORIZED USE UNDER FEDERAL LAW BY THE ARCHITECTURAL WORK5 OF THE HOLE SHALL NOT BE CLOSER THAN 5/8 TO THE EDGE OF THE STUD. REPORTS. EXISTING CAVITIES SHALL BE PROVIDED THE ENERGY USE OF THE BUILDING 15 COPYRIGHT PROTECTION ACT OF IggO (AWGPA), WHICH HAS SEVERE PENALTIES. NOTCHES AND HOLES SHALL NOT OGGUR IN THE SAME GRO55-5ECTION. 2.2. FAS TENERS AND CONNECTORS: ALL FASTENERS AND CONNECTORS SHALL ABOVE-GRADE WALL FILLED WITH NEW R-21 GATT NOT INCREASED, WHEN EXISTING CEILING, WALL, OR YES 25. FOR NEW WALLS, A PERFORATED 5HEARWALL SYSTEM 15 USED. THE CONFORM TO THE STANDARDS SPECIFIED IN M 2.2.1 THROUGH M 2.2.1. ALTERATIONS INSULATION OCR CAVITIES EXPOSED DURING CONSTRUCTION GENERAL WIND PROTECTION CONNECTION NOTES: CONTRACTORS ATTENTION 15 DIRECTED TO THE APPLICABLE DETAILS, ARE FILLED WITH INSULATION HAVING A NOMINAL ADAPTED FROM STANDARD FOR HURRICANE RESISTANT RESIDENTIAL NOTES, AND TABLES ON PAGE 6-005 $ 6-004. THE FASTENING 50HEDULE 2.2.1. BOLTS: BOLTS SHALL COMPLY WITH ANSI/ASME B I8.2.1 SQUARE AND VALUE OF R-3/INCH. N CONSTRUCTION;SST'D 10-qq AND 2018 SBC. HIGH WIND EDITIONI WOOD FRAME SPECIFIES THE REQ'D NAILING FOR THE 5HEATHIN6(ANY NAILING HEX BOLTS AND SCREWS (INCH SERIES). PER R503.1.1.3 Z CONSTRUCTION SPECIFICATIONS ON THE FLOOR PLANS SHALL 5UPER5EDE THE FASTENING I. A CONTINUOUS LOAD PATH BETWEEN FOOTIN65, FOUNDATIION WALLS, SCHEDULE). HOLDOWNS OPERATE IN CONJUNCTION WITH THE PERFORATED 2.2.2. LAG SCREWS: LAG SCREWS OR LAG, BOLTS SHALL COMPLY WITH ANSI/ COMPLIANCE STATEMENT: FLOORS, STUDS AND ROOF FRAMING SHALL BE PROVIDEED. 5HEARWALL SYSTEM (INSTALL AS PER APPLICABLE DETAILS d MANU. SPEC.'S). A5ME 515.2.1 5OUARE AND HEX BOLTS AND SCREWS (INCH SERIES). TO THE BEST OF MY KNOWLEDGE, BELIEF, AND PROFESSIONAL JUDGMENT, THESE PLANS AND SPECIFICATIONS ARE IN 0 2. APPROVED CONNECTORS, ANCHORS ,AND OTHER FASTENIINb DEVICES NOT HOLDOWN LOCATIONS ARE SPECIFIED ON THE FOUND✓FLOOR PLANS. 2.2.3. TRUSS METAL CONNECTOR PLATES: TRU55 METAL CONNECTOR PLATES COMPLIANCE WITH THE 2025 NYS ENERGY CONSERVATION CONSTRUCTION GORE U5INO CHAPTER 4 [RE]. INCLUDED IN THE STANDARD BUILDING CODE, SECTION 23106 OF IBC SHALL 26. COLUMN BEARING AS FOLLOWS: SHALL MEET THE REQUIREMENTS OF ANSI/TPI I NATIONAL DESIGN BE USED IN ACCORDANCE WITH MANUFACTURER'S RECOMtMENDATIONS. WOOD P05TIN6 TO BE BLOCKED SOLID TO FOUND. WALL W END &RAIN, STANDARD FOR METAL PLATE CONNECTED WOOD TRUSS CONSTRUCTION, TREATED WOOD b FLASHING. STEEL COLUMNS ARE TO BEAR UPON FOUND. THE GOVERNING BUILDING CODE AND ANY ADDITIONAL REQUIREMENTS 3. METAL PLATES, CONNECTORS, SGREhS, BOLTS AND NAILS EXPOSED WALL w/STEEL SHIMS 8 A MIN. 3/4" OF NON-SHRINK GROUT. A5 SET FORTH IN THE MANUFACTURER'S CODE EVALUATION REPORTS. T>4E;LE R501 .1 DIRECTLY TO THE WEATHER OR SUBJECT TO SALT CORROSION IN COASTAL SECURE 1-4/ (2) 1/2" 0 ANCHOR BOLTS (4" LONG EXPAN51ON BOLTS ® CLIMATIC $ OEOORAPHIC DESIGN CRITERIA w AREAS SHALL BE STAINLESS STEEL OR HOT DIPPED GALVANIZED. EXIST. WALLS $ 12" LONG HOOKED BOLTS ® NEW FOUND. WALLS). FOR ANY 2.2.4. METAL CONNECTORS WHERE METAL PLATE OR STRAPPING SIZE AND Q POSTING ® G.M.U. WALL SEE PLAN FOR REQUIRED REINFORCING (® MIN. 16" GAGE ARE SPECIFIED, ALLOWABLE DEFLECTION OF STRUCTURAL MEMBERS 4. WHERE WINDOWS AND DOORS INTERRUPT WOOD STRUCTURAL PANEL MINIMUM ASTM A653 STRUCTURAL QUALITY GROUND SNOW LOAD � 5HEATHIN6 AND SIDING, FRAMING ANCHORS OR CONNECTORS SHALL BE WIDE 5 COURSES OF SOLID BRICK MASONRY CENTERED ® POSTING,U.O.N). GRADE 55 STEEL SHALL BE USED. OTHER METAL CONNECTORS SHALL (p PER A50E 7-22) 50 L55 PROVIDED AT THE TOP AND BOTTOM OF CRIPPLE STUDS„ HEADER STUDS HOWEVER, WHEN COLUMN OR POSTING 15 PART OF THE LOAD PATH FOR USE MEET THE REQUIREMENTS OF THE GOVERNING BUILDING GODS AND ANY ALLOWABLE AND AT LEAST ONE STUD AT EACH 51DE OF OPENING. IN A SHEARNALL, ALL ANCHORS MAKING AN ATTACHMENT ARE TO BE w/ ADDITIONAL REQUIREMENT5 AS SET FORTH IN THE MANUFACTURER'S STRUCTURAL MEMBER BA510 WIND SPEED 150 MPH PROJECT: STANDARD 5HEARWALL HARDWARE (W NOTED VALUES) S ANCHOR BOLTS, CODE EVALUATION REPORTS. DEFLECTION 5. RIDGE STRAPS SHALL BE ATTACHED TO EACH PAIR OF OPP051N6, U.O.N. WITH TOP GAPS ® STEEL COLUMNS TO BE MIN.Y4" BENT PLATE 5" LONG NAILS: NAILS SHALL COMPLY HITH ASTM F EXPOSURE CATEGORY B RAFTERS EXCEPT WHERE COLLAR TIE-5 OF 1"xb" OR 2"x4'•" LUMBER 15 w/6" RISE 6 W (2) s/4"(P BOLTS THROUGH CENTER LINE OF VERTICAL LEGS 2.2.5.5PE SPECIFICATION FOR DRIVEN FASTENERS: NAILS,r SPIKES, AND STAPLES. RAFTERS HAVING SLOPES GREATER THEN 3/12 L/150 PAR I S LOCATED IN UPPER THIRD OF ATTIC SPACE AND ATTACHI TO EACH PAIR OF SET 6 DIST., U.O.N. - ADDITIONAL INFO. 15 FOUND ON PAGE 6-005. W/ NO FIN15HED CEILING ATTACHED TO RAFTERS RAFTERS. 2.2.6. PNEUMATIC, NAILS AND STAPLES: PNEUMATIC NAILS AND STAPLES SEISMIC DESIGN CATEGORY B COVERED PORCH 6. UPLIFT CONNECTORS SHALL BE PROVIDED AT EACH RAFTER BEARING. GLASS WINDOWS AND DOORS SHALL MEET THE REQUIREMENTS OF THE GOVERNING BUILDING CODE INTERIOR WALLS d PARTITIONS H/I80 I. ALL GLA55 TO BE INSULATED LOW-E, UNLESS OTHERWISE SPECIFIED. AND ANY ADDITIONAL REQUIREMENTS AS SET FORTH IN THE WEATHERING SEVERE '1. FLOOR TO FLOOR HOLD-DOWNS TO BE PROVIDED EVERIY 48" AND EVERY I6" WITHIN 4' OF EXTERIOR CORNERS. 2. GLASS DOORS AND WINDOW MANUFACTURER'S GORE EVALUATION REPORTS. FLOORS 6 PLASTERED CEILIN65 L/560 S SHALL NOT BE INSTALLED UNTIL PROPER FR05T LINE DEPTH 51-011 CLEARANCES ARE PROVIDED. 2.2.1. SCREWS: 5CR.EW5 SHALL COMPLY WITH AN51/A5ME B I8.6.1 8. SILL PLATE TO FOUNDATION ANCHORAGE;SILL PLATE SHAALL BE ANCHORED WOOD5CR.EW5 (INCH SERIES). ALL OTHER STRUCTURAL MEMBERS L/240 1855 GREENWAY EAST 3. ALL SLIDING GLA55 DOORS, SKYLIGHTS, AND ANY GLA55 UNIT INSTALLED TERMITE MODERATE TO HEAVY ORIENT NY 11957 TO THE FOUNDATION WITH ANCHOR BOLT5 HAYING A MIN., BOLT DIAMETER WITHIN IS" OF FINISHED FLOOR SHALL BE OF INSULATED TEMPERED GLASS, OF J" AND V'xV'x�" WASHERS. A MINIMUM OF ONE ANGHOFR BOLT SHALL BE UNLESS OTHERWISE NOTED. ASPHALT ROOFING SHINGLES EXTERIOR WALLS W/ PLASTER OR STUCCO FINISH H/360 PROVIDED WITHIN b TO 12 INCHES OF EACH END OF EACH PLATE. ANCHOR I. ALL SLOPED ROOFING SHINGLES SHALL BE GAF-CLASS-A ASPHALT ROOFING ICE BARRIER REQUIRED YE5 SHINGLES OR APPROVED EQUAL. BOLTS SHALL HAVE A MINIMUM EMBEDMENT OFT' IN CON40R.ETE/MA5ONRY 4. ALL GLA55 UNITS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH EXTERIOR WALLS - WIND LOADS W/ BRITTLE FINISHES L/240 FOUNDATIONS. ANCHOR BOLTS SHALL. BE LOCATED WITHIIN 12" OR CORNERS MANUFACTURERS SPECIFICATIONS. DRAWING TITLE: 2. SHINGLES SHALL BE APPLIED OVER 15# BUILDING FELT, UNLESS OTHERWISE AND AT SPACING NOT EXGEEDIN5 4 ON CENTER. NOTED. ALSO, CONTRACTORS OPTION TO APPLY GAF-WEATHER-WATCH ICE EXTERIOR WALLS - WIND LOADS W/ FLEXIBLE FINISHES L/120 GENERAL NOTES 5. ALL WINDOWS TO BE CAULKED AND SEALED AS PER NEW YORK STATE AND WATER BARRIER FROM EDGE OF EAVE TO 24" INSIDE EXTERIOR WALL CODES AND REFERENCE STANDARD: ENERGY CONSERVATION CONSTRUCTION GORE. LINE. b 24" FROM ALL VALLEYS, AND ROOF FLASHING CONDITIONS. ENERGY TABLE 1.STL NFkq ATE BUILDO G GODS, 202E NEW RK PERFORMED SHALL CONFORM TO RESIDENTIAL HE2025 NEA YORK 6. PROVIDE FLASHING PANS UNDER ALL SLIDING GLA55 DOORS, WINDOWS, OR 5. PROVIDE FLASHING NECESSARY FOR WATER TIGHT AND WEATHERPROOF NEW BUI STATE PROPERTY NENMAI YORK STATE GODS, AND 202E5 NEW PORK ANY OTHER TYPE OF 6LAS5 UNIT WHEN WITHIN 6 OF AN EXTERIOR SURFACE. CONSTRUCTION. STRUCTURAL DESIGN CHARTS STATE ENERGY CONSERVATION CONSTRUCTION CODE. 1. ALL EXTERIOR DOORS ARE TO BE WEATHERED STRIPPED AND PROVIDE ALL 4, ROOFING IS TO BE APPLIED IN STRICT ACCORDANCE WITH MANUFACTURER'S 2. REFERENCE STANDARD USED FOR ALL WOOD FRAMING, CONNECTIONS OF SCREENS AND HARDWARE NECESSARY FOR PROPER FUNCTION OF SUCH UNITS. SPECIFICATIONS. STRUGTURL DESIGN LOADS WOOD FRAMING, AND CONNECTION TO FOUNDATION - 2024 HOOP FRAME g, ALL GLASS 15 TO BE FREE OF SCRATCHES AND IMPERFECTIONS. GLASS CONSTRUCTION MANUAL BY THE AMERIGAN FOREST $ PAPER: A550CIATION SHOULD BE GUARANTEED BY THE MANUFACTURER FOR A PERIOD OF 5 YEARS. 5. NAILING OF ROOFING SHALL BE TO CODE. USE LIVE LOAD DEAD LOAD PAGE: (AFPA) AMERIGAN WOOD COUNCIL (AWC:). 6. CORROSION RESISTANT 11 GAGE ROOFING NAILS AND 16 GAGE STAPLES ARE g. ALL WINDOWS To BE ANDERSEN. IF CONTRACTOR IS TO SUBSTITUTE WITH PERMITTED 3. ALL PLUMBING WORK SHALL CONFORMTO THE 2025 NEW'YORK STATE ANOTHER WINDOWMANUFACTURER, IT IS THE RESPONSIBILITY OF THEEXTERIOR BALCONIES 40 psf 15 psfG-002mOO PLUMBING CODE. CONTRACTOR TO VERIFY THAT THE CHARACTERISTICS OF THE WINDOW MATCH THE CHARACTERISTICS OF THE ANDERSEN WINDOW SPECIFIED. THE "1. PROVIDE (2) LAYERS OF 15# ASPHALT BUILDING FELT UNDERLAYMENT FOR 4. ALL MECHANICAL WORK SHALL CONFORM TO THE 2025 NEW YORK STATE CHARACTERISTICS ARE AS FOLLOWS, BUT NOT LIMITED TO: DE51ON PRESSURE, 2:12 PITCHES TO 4:12 PITCHES DECKS 40 psf 15 psf MECHANICAL CODE AND 2025 NEW YORK STATE FUEL GAS CODE. ROUGH OPENING,U-FACTOR, LIGHT AREA, VENT AREA, AND EGRESS 8. ASPHALT SHINGLES SHALL BE TESTED TO DETERMINE THE RESISTANCE OF 5. ALL ELECTRICAL WORK SHALL CONFORM TO 2011 NATIONAL ELE07RIG REQUIREMENTS. THE SEALANT TO UPLIFT FORGES U51NG A5TM D 6551. PASSENGER VEHICLE GARAGES 50 psf AS PER PLAN 10. WINDOWS IN TUB/SHOWER ENCLOSURES AND WITHIN STAIRWAYS SHALL BE DATE: 03 30 26 GODS, NFPA 70 AND 2025 NEW YORK 51'ATE ENERGY CONSERVATION UNINHABITABLE ATTICS WITHOUT STORAGE 2 OF 5 CONSTRUCTION GODS. TEMPERED &LASS. (MAX CLEAR HOT< 42") 10 psf 15 psf GYPSUM WALL BOARD ATTICS WITH STORAG E 11. EXTERIOR GLAZING IN BUILDIN65 LOCATED IN WINDBORNE DEBRIS R.EGION5 1. GYPSUM WALL BOARD SYSTEMS SHALL BE OF A TAPE JOINT AND JOINT UNINHABITABLE20 psf 15 psf SHALL BE PROTECTED FROM WINMBORNE DEBRIS. GLAZED OPENING COMPOUND METHOD. (MAX CLEAR HOT > 42 ) SITE WORK PROTECTION SHALL MEET THE R'.EOUIREMENTS OF THE LARGE M1551LE TEST OF HABITABLE ATTICS d I. STAKEOUT 15 TO BE PERFORMED BY A LICENSED SURVEYOR ASTM Eiggb AND ASTM E1886. GARAGE DOOR GLAZED OPENING PROTECTION 2. ALL 6YPSUM BOARD SHALL BE 1/2" ON WALLS AND GEILIN6, UNLESS ATTICS SERVED BY FIXED STAIRS 30 psf 15 psf 2. VERIFY ALL GIVEN DATA ON DRAWINGS. IF THERE 15 A D>ISGREPANCY, SHALL MEET THE REQUIREMENTS OF AN APPROVED IMPACT-R.E515TANT OTHERWISE NOTED. WATER RESISTANT (W.R) AT BATHROOMS AND WHERE RECEIVE CLARIFICATION FROM ARCHITEC T/ENOINEER PRIOR TO PROCEEDING. STANDARD OR AN51/DASMA 115. (NYS RG R501.2.1.2) DEEMED APPLICABLE. ROOMS OTHER THAN SLEEPING ROOMS 40 psf 15 psf � � r 3. EXCAVATE AND BACK FILL FOR WORK: INDICATED ON DRAWINGS. 12. AS AN ALTERNATIVE TO NOTE #II ABOVE, WOOD STRUCTURAL PANELS WITH 5. 5/8", ONE HOUR RATED, TYPE 'X' 6YP5UM BOARD ON GEILIN6 AND WALLS 9. SLEEPING ROOMS 30 psf 15 psf (WHERE APPLICABLE) AT HEAT PRODUCING EQUIPMENT TO EXTEND THREE FEET _ STOCKPILE TOPSOIL OBTAINED FROM 57RIPPING DRIVEWAY AND BUILDING A THIGKNE55 OF NOT LESS THAN AND A SPAN OF NOT MORE THAN 8 SHALL IN EACH DIRECTION BEYOND THE UNIT(5). ALSO AT HEAT PRODUCING SITE. STOCKPILE ALL EXCAVATED MATERIALS. BE PERMITTED AS GLAZING PROTECTION. PANELS SHALL BE PRECUT AND EQUIPMENT, CONCRETE FLOOR OR IF PLACED ON WOOD FRAME, INSTALL STAIRS 40 psf 15 psf � ATTACHED TO THE FRAMING SURROUNDING THE OPENING. PANELS SHALL BE 4. NEW AND EXISTING BACK FILL MATERIAL ARE TO BE FREE OF WEEDS, TREE PR.EDRILLED AND SECURED WITH THE ATTACHMENT HARDWARE PROVIDED AS CONCRETE PANELS OF 5/8" THICKNESS MINIMUM. ROOTS, ROCKS, AND DEBRIS. ALL SURPLUS MATERIAL THAT 15 UNSUITABLE PER THE ANCHORAGE METHOD SELECTED IN ACCORDANCE WITH TABLE GUARDRAILS AND HANDRAILS 200 psf 15 psf 4. FINISH JOINTS J-BEADS, NAIL DIMPLES, CORNERS AND EDGES SHALL BE p p ` FOR BACK FILL MATERIAL SHALL BE REMOVED FROM SITE. R501.2.1.2. ATTACHMENT HARDWARE SHALL BE PERMANENT TAPED AND RECEIVE THREE GOATS OF JOINT COMPOUND. ALLOW 24 HOURS o a°1 CORROSION-RESISTANT AND THE ANCHORS SHALL BE PERMANENTLY INSTALLED ara TO DRY BETYJEEN GOATS. FINAL GOAT TO BE SANDED SMOOTH. �'��' 5. PROTECT TREES WITHIN EIGHT FEET OF THE BUILDING. ON THE BUILDING. ROOF LOADING (LIVE = GROUND SNOW LOAD, p� 50 psf 15 psf F [gip u ,F 5. METAL CORNER BEAD TO BE USED ON ALL OUTSIDE CORNERS AND AROUND NOTE: ASD GROUND SNOW LOADS, pgrAs�J=o.7p9 ' (� ALL OPENINGS. 6. FASTEN 6YP5UM BOARD AS PER FASTENING 5GHEDULE ON PAGE 6-003. 'BALL STRUCTURAL DESIGN CONSIDERATIONS ARE IN CONFORMANCE WITH ASGE "1-22 (MINIMUM ME51ON LOADS FOR BUILDIN65 AND OTHER 5TRUCTURES) (5E I `AF_f;P,AL 5""r�450 - <E**�r EXISTING TO BE DEMOLISHED / NEW PARTIAL HEIGHT - WOOD FRAME (L.G. STL. Q EXISTING TO REMAIN WHEN APPLICABLE) DEMOLITION NOTE: EXIST. POOL ui PROVIDE SHORING AND SUPPORT TO ALL AFF`EGTED - NEW FOUNDATION WALL STRUCTURAL MEMBERS PRIOR TO THE GOMMEtNCEMENT NEW WOOD FRAME (L..G. J STL. WHEN APPLICABLE) OF ANY DEMOLITION OR CONSTRUCTION. cu m MIN. (2) 2"x4" 5TRUGTURAL fV NEW I-HR FIRE RATED W ® P05T FOR 4" ALLS C � WOOD FRAME (L.G. STL. (MIN. (2) 2"x6" STRUCTURAL � WHEN APPLICABLE) P05T FOR 6" WALL5), U.O.N. O 7F 0 NEW 2-HR FIRE RATED C9 WOOD FRAME (L.G. STL. � � NEW PLUMBING WALL •L WHEN APPLICABLE) a •� i X N EXIST. SLATE PATIO O O O O m cj �,, c NO cB Q C.� O Ll : ILI X wr 1 ------t ------,I RE-REROUTE EXIST. BATHROOM DEMOLISH PORTION OF _ EXIST. BATHROOM VENTS (V.I.F)� VENT THROUGH NEW ROOF SOFFIT EXIST. WALL AS REO'V FOR PROP. DOOR5 ail EXIST. WD. STOOP 111 DEMOLISH EXIST. STOOP F RELOCATE EXIST. U I1 I1 MULLED WINDOWS EXIST. OVEN HOOD VENT N.I.F.)�II"I IIIII lIIIIrIIfII lI11 I111rf11 111�--_-----III1II------1-J��1III 1IIII1 1IlI1 REMOVE d RELOCATE -- IIlI 11 >� II II1 DEMOLISH PORTION OF - -----------, EXI53T. MULLED WINDOW51 111 O~ I EXIST. WALL AS REQ.'D FOR � Q11 RELOCATED WINDOWS In • } L 1 1 1 11 1 IL--I--J1 ---- EXIST. OUTDOOR SHOWER REMOVE EXIST. n I 1 1 1 1 1 1 1 rl 1111 I II 111 I IIl I / , DOORS, EXTERIOR -i IIIII LL__I=_J�ILL:__I_=Ji1 1 v LIGHTS, 4 REAR STOOP H i i i 1 11 i H L------------- j 11111 11 11111 IIIII 11 IIIII IIIII 11 III II F.F. I I L___J L.___I I i 1 I — — — — — — — — — — EXIST. DWELLING (NO WORK PROPOSED WITHIN)— FROFCSE1�) r>)EMOL I TI ON - NEST ELEVATION (REAR) PROPOSED I�)EMOL I TI ON PLAN 50ALE: 1/4" = 1'-0" SCALE: 1/4" = I'-O" EXIST. POOL D 0 EXIST. SLATE PATIO H NATURAL WOOD DEGKIN6 AND STEPS TO MATCH FRONT Z LEI w PORCH;STAIN TIED;WRAP SIDES OF NEW STEPS WITH g NEW 5TANDING DEGKIN6 g 12 SEAM METAL ROOF 14'-0" II'-3" 0 EXIST. BATHROOM VENT N.I.F.) 1 4 UNDERSIDE PROVIDE CEDAR FINISH AT ERSIDE OF ROOF;FINISH TO PROVIDE NEW COVER FOR MATCH EXISTING FRONT PORCH EXISTING VENTS F EXIST. OVEN HOOD VENT (V.LFJ H (V.I.FJ Q N — — — — — — — — — 5 O 5 &-8" CLC. H6T. O PROJECT: Ll Eln m T rn PROP. REAR (V ATSOFFIT) - ----- ib COVERED PORCH 6PA R I S >-L �\ RELOCATED INFILL WALL WHERE DOORS 4 �\ RELOCATED COVERED PORCH WINDOWS WINDOWS REMOVED; INSTALL 1-`I 6 O (V.I.FJ WINDOWS EXIST. OUTDOOR SHOWER I _ NEW 51DINO TO MATCH EX15TING N.I.FJ WALL INFILL — — — — — — — — — CENTER DOORS ✓! lx - - -- - - - PROP. RE°AR COVERED WINDOWS BELOW 2ND 1855 GREEN WAY EAST PORCH k ENTRY FLOOR WINDOWS ABOVE EXIST. DWELLING ORIENT, NY 11957 (NO WORK PROPOSED WITHIN) m DRAWING TITLE: PROP. DEMOLITION ELEVATION FRCFOSETD NEST ELEVATION (REAR) FROFOSED F I R57 FLOOR PLAN PROP. DEMOLITION PLAN PROP. ELEVATION & FLOOR PLANS SCALE: 1/4" = 1'-0" SCALE: 1/4" = I'-O" FLOOR PLAN NOTES PAGE: DOOR NOTE: VIEW GUTTER D Oj 1. INSTALL NEW ANDERSEN 400 SERIES FWH6080 O TO MATCH EX15TINO CUTTERS p FRENCH IDOORS — A-101m00 2.INSTALL AS PER MANUJ SPEG.'s 4 3 5. SEE PAGE 5-101 FOR BALL FRAMING ELEMENTS AROUND O4 GUTTER HIGH POINT (TYP.) DOORS (TYP. FOR ALL DOORS $ WINDOWS) U.O.N. 5 OSTAIR NOTE: O NEW DOWNSPOUT s �DATE: 03 30/26 1. ALL NEW STAIRS SHALL HAVE MAX. 5-1/4" RI a MIN. 10" TO MATCH EXISTING DOWNSPOUTS Sy2 (TYP. OVERHANG) 3 OF 5 Tr - RISERS SHALL BE CLOSED EXTERIOR WALL IN-FILL: 2. GREATEST R15ER HEIIGHT IN A FLIGHT OF STAIRS SHALL \1:2 tV NOT EXCEED THE SMALLEST BY MORE THAN O IN-FILL EXTERIOR WALL WHERE DOORS/WINDOW5 REMOVED: • �Y 3. HEADROOM SHALL BE AT LEAST 6'-8" I. NEW SIDING TO MATCH EXISTING,UPON 4:12 4. HANDRAILS SHALL BiE YV PROVIDED ON NOT LESS THAN 2• TEK HOUSE WRAP (VENTED) (OR EQUAL), 4 4 ONE SIDE OF EACH FLIGHT OF STAIRS CONTAINING FOUR OVERLAPPING EXISTING HOUSE WRAP 12" MIN., UPON OR MORE RISERS, AND WHERE SHOWN ON PLANS. 5.J" CDX PLYWOOD SHEATHING(PROVIDE BLOCKING AT 5. 5UARDRAILS SHALL BE PROVIDED FOR OPEN-SIDED ALL PLYWOOD 5EAM5),UPON WALKING SURFACES LOCATED MORE THAN 50" ABOVE 4.2"xb" STUDS ® 16" O.G. (PROVIDE NEW AS REQ.'D), UPON FINISHED FLOOR OR GRADE, 8 WHERE SHOWN ON PLANS. 5. GYPSUM WALL BOARD, FINISHED TO MATCH EXISTING g 6. 56" HIGH GUARDRAIL d SPINDLE SPACING NOT TO (o.FILL ALL CAVITIES w/R-21 BATT INSULATION .ALLOW PASSAGE OF: A 4" 0 SPHERE;56" HIGH '1. INSTALL ALL AS PER MANU 5PEG.'s HANDRAIL. -I. CRIPPABLE RAIL AS PER CODE s = EXIST. DWELLING (NO WORK PROPOSED WITHIN) Xvxvx\\� �rF2` FROFOSF_17 ROOF PLAN 5GALE: 1/4" = 1'-0" BUILDING SECTION NOTES ONEW ROOFING NOTE (TYPJ: I. INSTALL NEW STANDING SEAM METAL ROOFING. 2.INSTALL ICE AND WATER SHIELD FROM FASCIA UP TO a 24" FROM INSIDE FACE OF STUD WALL AND AT VALLEYS Q 5.INSTALL HENRY BLUESKIN PE20OHT SYNTHETIC ROOF' UNDERLAYMENT (OR APPROVED EO) OVER W 4.I/2" GDX PLYWOOD SHEATHING (BLOCK ALL SEAMS) J co 5. 6ALV. METAL GAP OVER RIDGE b HIPS (AS REO'D) 6.PROVIDE RIDGE VENT (A5 REO'D) m 7. FLASH ALL VALLEYS Q :t N &.INSTALL DRIP EDGE AS REO'D I cl� O Lr) a. INSTALL ALL AS PER MANU. SPEC.'s 12 GO-ORDINATE BIR05MOUTH TO 4 O EXTERIOR WALL IN-FILL: ENSURE R.R. NOTCHED LE55 THAN O IN-FILL EXTERIOR WALL WHERE DOORS/WINDOWS REMO\\/ED: 25% OF RAFTER DEPTH (TYP) a--� 0 �- 0 I. NEW SIDING TO MATCH EXISTING, UPON EXIST. F.J. i z O 2."TY,/EK" HOUSE WRAP (VENTED) (OR EQUAL), OVERLAPPING EXISTING HOUSE WRAP 12" MIN., UPON O O N 5. �" GDX PLYWOOD SHEATHING (PROVIDE BLOGKIN6 A'T CD' Lr) s_ ALL PLYWOOD SEAMS),UPON c 4.2"xb" STUDS ® 16" O.G. (PROVIDE: NEW A5 REQ.'D),UPON O G X O (V 5. GYPSUM WALL BOARD, FINISHED TO MATCH EXISTING, 0 m '.�3 C0 6.FILL ALL CAVITIES w/R-21 BATT INSULATION EXIST. ° a-J N � _ ° / o'7. INSTALL ALL AS PER MANU SPEC:.'s DWELLING Q � L 2: O N 2 I I W }EXIST. F.J. EXI5T. SLATE PATIO j v • � D / W ° U c Q . - 1. CREATE WINDOW OPENING 2. APPLY WATER-RESISTIVE BARRIER; 5. APPLY SILL FLASHING AND 4. INSTALL WINDOW AND APPLY 5. APPLY HEAD FLASHIN6 6. FOLD WATER-RESISTIVE BARRIIER �+ GUT MODIFIED AND WRAP AROUND SILL WINDOW SEALANT JAMB FLASHIN6 DOWN AND TAPE OVER GUTS r1 AND SIDE5 OF WINDOW OPENING (D GPM SECTION I - I/A-201 NATER-RESISTIVE BARRIER N I NDON FL A5H I NO (EXTERIOR DOORS FROM N I MOON MANUfAOTURrZR) &GALE: 1/4" = 1'-0" A-201.00 SCALE: NTS PROVIDE 5'-6" HIGH GUARDRAILS w/ MAX. 4" BETWEEN ED6E5 OF 1-1/2" SQUARE BALUSTERS AT DEGK5 50" OR MORE ABOVE 6RADE. PROVIDE 5'-0" HIGH HANDRAIL5 AT STAIRS w/FOUR OR MORE RISERS P.T. D.J. AS WRAPPED POST OR COLUMN ABOVE, A5 PER PLAN NOTED SEPARATELY ON STRUCTURAL EXTERIOR SHEATHING AS PLANS. FASTEN P05T TO BEAM BELOW PER SECTION NOTES J"xb" P.T. AS NOTED ON STRUCTURAL PLANS. TYP. ROOFING (SEE DECK BOARDS 51DIN6 MATERIAL AS NOTE: SECTION NOTES) P.T. BEAM AS NOTED ON STRUCTURAL PLANS PER SECTION NOTES HANDRAIL TO BE PROVIDED 5/4" x REO'D BUILDING PAPER t HOUSE WRAP WITH (4) OR MORE RISERS HEIGHT P.T. RISER SIMPSON 6ALV. H2.5A TO FULLY OVERLAP FLASHING RAFTER TIE FASTEN STRINGERS TO DROPPED BM. w/ SIMPSON L50" ADJUSTABLE STRINGER CONNECTORS STUD WALL 5/4" THK. P.T. GO-eORPINATE BIRD5MOUTH 51MP50N 6ALV. ABU66Z P05T BASE (OR EQUAL); NOTE' DECK BOARDS TOENSURE R.R. NOTCHED pyp•� ENSURE 2" MIN. GONG. COVER ON ALL SIDES d ALL DEGKIN6 SHALL BE FASTENED LESS THAN 25% OF p�� 51MP50N H2.5A HURRICANE "Z" FLASHIN6 5/4"xb" P.T. DEGKIN6 w/COATED DEGKIN6 SCREWS BY 1" RAFTER DEPTH (TYP) R'�' TIE (OR EQUAL) PROVIDE (2) �"x'1"xl0" WD. STRUCTURAL PANEL "DECK MATE" (OR EQUAL) � SHIM ALONGSIDE BEAM, PER MANU DOG.S N.O.N. ON PLAN/ NOSING GAP FOR 5EGTION/DETAIL5) (TYF ' DRAINAGE 4" THK. x 12" WIDE x WIDTH OF STAIR P. GONG. PAD i5" V.I.F ° G.J. PER PLAN GRADE W.F. (11I EXIST. SLATE PATIO _ V7, " FASCIA BOARD 12"� "SONOTUBE" FILLED jlljll N 2"xb" P.T. BLOCK IN BETWEEN _ SOLID w/P. GONG. IIIIIi% w BEAM AS PER 51MP50N LU5 (MIN. 4,000 PSI) 11111 "m ANCHOR BOLT w/ I&" EA. 5TRINGER. FASTENED TO 2"xl2" P.T. 5TRIN6ER5 ® 16" STRUCTURAL PLAN 6ALV. JOIST .111111 P. GONG. PAD w/ la/64" x tt1 O.G. (MIN. 5 STRINGERS ® HANGERS AT d p 1'd MIN. EMBEDMENT DEPTH p METAL DTT DECK (2) #5 BENT REBAR c� 5-1/2 CONCRETE 5GREWS BY t' EA. STAIRWAY) FLUSH BM. 4 (CENTER BETWEEN SQUARE FOOT SF-28 JOISTS AS PER PLAN FASTENED w/ (2) TENSION TIE BY "CALIBURN" (OR EQUAL) - MIN. LEDGER BD. PARALLEL REBAR IN FTC) 5/&" 0 x 5" LONG HEAVY DUTY GAL. 'SIMPSON' (OR EQUAL) (5) 5GREWS PER BLOCK 10" MIN. CONCRETE FOOTING _ LAG BOLTS ® I6 D.G. INTO MUD SILL P.T. DECK JOIST 'I IL FORM FILLED SOLID w/ RIM BD.;WHEN ® FOUND. WALL FASTEN AS PER PLAN EXIST. SLATE PATIO (5) #5 HOR. REBAR 11•11 P. GONG. (MIN. 4,000 w/(2) 5/&"0 x 5" LONG APPROVED SIMPSON F05T GAP AS UPON (2) #5 HOPTAL eALV. JOIST , REBAR • d .11 d P51); INSTALL PER MASONRY ANCHORS ® I6" O.G. FLA514 NG HANGER BY 51MPSON' PER STRUCTURAL PLAN W FOUNDATION WALL (OR EQUAL) ® EA. JOIST (5 TOTAL) COORDINATE 1 MANU. SPECS. w/PLACEMENT OF BENT III d d REBAR •. I I• d ••dll 11 ---- ---ra PROJECT: in �4" 4" PARISI 2 LEI7OER OONNEOTI ON I7ETA I L. EXTERIOR V400D STAIR I7E7A I L- COVERED FORCH DE7A I L- 00\/EREl�) FOROH FOUNI7A.71 ON UETA I L_ COVERED PORCH A-20I.00 _ A-201.00 _ „ -2C>I.00 -201.00 SCALE: I" - I O &GALE: 3/4„ - I -O &GALE: 3/4" = I'-O" &GALE: 3/4" = I"-O" 1855 GREENWAY EAST ORIENT, NY 11957 DRAWING TITLE: PROP. BUILDING SECTION DESIGN DETAILS PAGE: A-201. 00 DATE: 03/30/26 4 OF 5 :'rye.^'�>.�F,-..,,• °�.;',a Cie) o n t POURED CONCRETE AND STEEL REINFORCEMENT NOTES: I. ALL EXCAVATIONS SHALL NOT UNDERMINE EXIST. ADJACENT FOUNDATIONS BY AN ANGLE OF 45° PROJECTED OUTWARD AND NEW PARTIAL HEIGHT DOWNWARD FROM THE BOTTOM OF EXISTING ADJACENT FOOTINGS. a _ EXISTING TO BE DEMOLISHED , , WOOD FRAME (L.G. STL. 2. IF WATER ENCOUNTERED DURING POURING OF GONG., EXCAVATION Q EXISTING TO REMAIN WHEN APPLICABLE) SHALL BE DE-WATERED. THE POUR SITE SHALL REMAIN DRY FOR c) ENTIRETY NEW WOOD FRAME (L.6. NEW FOUNDATION WALL ENCOU OUR. CONTACT ARCHITECT WHEN WATER W ENCOUNTERED. I- �-I W � STL. WHEN APPLIGABL;=) J 3. POURED CONCRETE SHALL BE KEPT MOIST FOR A MIN. OF 14 DAYS. cy) MIN. (2) 2"x4" STRUCTURAL Q N ® 4. ALL FOUNDATION WORK SHALL BE 4,000 P51 POURED CONCRETE AT - NEW I-HR FIRE RATED POST FOR 4 WALLS 25 DAYS AND SHALL CONFORM TO THE CURRENT AGI 318 CODE. .� WOOD FRAME (L.6. 5TL. (MIN. (2) 2"xb" STRUCTURAL WHEN APPLICABLE) P05T FOR b" WALLS), U.O.N. 5. ALL REINFORCEMENT BARS SHALL BE DEFORMED CARBON STEEL A5TMA615 GRADE 60. WWM FOR 5LA55 DO NOT NEED TO BE y. NEW 2-HR FIRE RATED COATED. 4-J WOOD FRAME (L.G. STL. NEW PLUMBING WALL L O fV z 0 WHEN APPLICABLE) 6. U.O.N., REBAR LAPS SHALL BE A MIN. OF 40 DIAMETERS. ALL LAPS 0 - C\j Y 1 SHALL BE 5TA66ERED. •f6 r 1. PROVIDE MECHANICAL DEVICES TO HOLD STEEL 4 HARDWARE IN C 2 X :3 (V 1 TYPICAL DOOR/WINDOW HEADER NOTE: PLACE AT TIME OF POURING a MAINTAIN REQUIRED CLEARANCES, C9 STRUCTURAL FLAN NOTES PROVIDE (2) 2"xIO" HEADERS AT ALL DOORS 8 WINDOWS, U.O.N. +� 0 SEE PACE 6-003 FOR NAILING/5TRAPPIN6/FRAMIN6 REQUIREMENTS COVERAGES, AND PLUMBNESS. � � m �} ' � O6 xb P05T w/ COLUMN 0651N(5: (BY OPENING WIDTH) THAT SHALL BE PROVIDED,U.O.N. I. PROVIDE 6'xb" P.T. PO5T INSIDE Ix AZEK COLUMN WRAP. SUCH TYPICAL HEADERS ARE PORTRAYED ON PLANS AS SUCH: 8. CEMENT SHALL CONFORM TO ASTM C-33 FOR STANDARD WEI6FiT Q � c� 2. CONNECT POST TO BEAM w/SIMPSON ACH6Z POST GAP 18'-3" 2NV F CONCRETE. Q d G O (PROVIDE 5HIMMIN6 AS REWD TO MATCH BEAM WIDTH CENTER COVERED PORCH w/ 2ND FLOOR WINDOWS ABOVE TO POST GAP WIDTH). 3. CONNECT POST TO 5UPPORTIN6 BEAM w/ SIMP50N I'-O I'-O" CONCETE - GOLD WEATHER POURING a CONCRETE MIXTURE M5TC6653Z PRE-BENT STRAP (w/MAXIMUM NAILING). 4. SEE ALSO DETAIL 4/A-201. 1. THESE SPECIFICATIONS SHALL APPLY FOR THE POURING OF NEW 2 xl2 P.T. CONCRETE IN TEMPERATURES UNDER 45° F IF THAT TEMPERATURE OCOVERED PORCH FOUNDATION: STR G PIS HAS BEEN SUSTAINED FORA 24 HOUR PERIOD OR MORE. 2 - WD. P.T. BM. (PER PLAN), UPON 501E BEARING CAPACITY NOTE: alb" O.G. - SIMPSON ABU66Z POST BASE, UPON STRUCTURAL DESIGN OF FOOTINC75 A55UMES A SOIL _ _ _ _ _ - 12"cP P. GONG. PIER,UPON BEARIN6 CAPACITY OF 1.0 TON/S.F. NEW 2"xb" P.T. 2. SPECIFICITY OF CONCRETE DESIGN MIX SHALL BE BY OTHERS. - "SQUARE FOOT" 5F-28 GONG. PAD FTC. BEARIN6 6'-6" 2 - - - P.J. a O.G. 3. ALL GOLD WEATHER PREPARATIONS AND CONCRETE POURING SHALL ••}-•J BELOW GRADE. ROOF RAFTER TO SUPPORTING MEMBER CONNECTION: CONFORM TO AGI 506. AS PER DETAIL 5/A-201. FASTEN EACH RAFTER TO SUPPORTING MEMBER (RIDGE BEAM, - - - - - - - U O TYPICAL LEDGER BOARD a EXT. DECK: HIP,VALLEY,OR LEDGER) w/SIMPSON LRUZ FACE-MOUNT - „ „ - 4. IN NO CASE SHALL GONGRND A FLARED ON FROZEN GROUND /3 I. (1) 2"x P.T. BD. TO MATCH DEPTH OF JOISTS RAFTER HANGER (SELECT MAXIMUM HANGER 51ZE COMPATIBLE NEW DROPPED BM.P.T. SURFACES. FROZEN GROUND MA TEMPERATURES WITHIN 10° F OF CONCRETE. WY BE REMOVED OR HEATED TO ( 2. SECURED w/(2) 5/8" 0 x 5" LONG H.D. GAL. LAG BOLTS w/ RAFTER DEPTH),UNLESS NOTED OTHERWISE. - a I6" O.G. 00 S 3 W 3. INSTALL H.D. 6ALV. JOIST HANCER5 BY 'SIMP5ON' (OR NASE HALL CONCRETE BE PLACED ON ICE OR SNOW. -"�--J - - - - REMOVE AS REQ'D. . EQUAL) 4. FOR EXTERIOR INSTALLATIONS,PROVIDE FLASHING 6. THE USE OF HEAT BLANKETS OR ELECTRIC BLANKETS ARE TUCKED UNDERNEATH 51MINO # BENT OVER TOP EDGE PERMITTED WHEN NECESSARY. OF LEDGER BD. ' ` 5. SEE DETAIL 2/A-201 -I. FORMWORK SHALL BE AT A MIN. TEMPERATURE OF 33° FOR HIGHER v AND SHALL BE WITHIN 10° F OF CONCRETE TEMPERATURE. 8. CONCRETE SHALL BE AIR ENTRAINED FOR GOLD WEATHER POURING. EXIST. DWELLING q. NON-CHLORIDE, NON-CORROSIVE ACCELERANT ADMIXTURES ARE Q • (NO WORK PROPOSED WITHIN) PERMITTED TO BE ADDED TO CONCRETE MIXTURE AS PER AGII 306 (A5TM C494/C4Q4M, TYPES G AND E). W (GONTI NUOUS E3U I LT-UP O I R17)ERS, 5 OR MORE SUPPORTS 10. CONSULT ARCHITECT WHEN STEEL EMBEDDMENT GROSS SECTIONAL Q GONNEGTION PATTERN 5GHEIDULE AREAS EXCEED ONE SQUARE INCH. BETWEEN I/6 ASSEMBLY REQUIREMENTS: II. ONCE CONCRETE 15 PLACED. CONCRETE SHALL NOT BE EXPOSED a of A WHEN GIRDERS MADE UP OF JOISTS NAILED TO REPEATED FREEZING AND THAWING UNTIL CONCRETE HAS CONNECTION DESCRIPTION TOGETHER SIDE BY SIDE ARE CONTINUOUS OVER REACHED A COMPRESSIVE STRENGTH OF 800 PSI. PATTERN THREE OR MORE SUPPORTS, JOINTS ARE TO BE MAX.52" LOCATED BETWEEN ONE SIXTH AND ONE QUARTER 12. PLACEMENT TEMPERATURES SHALL CONFORM TO AGI 306. A (2)ROWS IOd NAILS m 12"o.G. THE SPAN LENGTH FROM AN INTERMEDIATE B (3)ROWS IOd NAILS a 12"O.C. SUPPORT. NO TWO ADJOINING JOISTS, NOR MORE PROPOSED FOI V IN�AT 1 ON FLAN L /'\l-t N P` THAN ONE THIRD THE TOTAL NUMBER, ARE TO BE G (2)ROWS 1/2" m BOLTS• 12"O.G.STA66ERED; JOINTED ON THE SAME SIDE OF THE SUPPORT. TWO-PIECE SCALE: I/4" = I'-O" DBE.a ENDS ;BUILT UP 61RDER P` MAX.32" D (2)ROWS 1/2" m BOLTS• 16"O.G. NAILING: TWO-PIECE GIRDERS ARE TO BE NAILED FROM ONE E 11(2)ROWS 1/2" m BOLTS• 24"O.G. 51DE WITH lod NAILS, TWO NEAR EACH END OF BETWEEN 1/6 EACH PIECE, OTHERS STAGGERED WITH A DISTANCE Rows F (2) 5-3/a"TRUSSLOGK 5GREKs• 12°O.C. a V4 of A OF 16 INCHES BETWEEN NAILS IN A HORIZONTAL SCREWED ON(1)SIDE OF MEMBER LINE; OR GIRDERS ARE TO BE NAILED FROM EACH G (2)ROWS 5-3/8"TRUSSLOGK SCREWS a 16"O.G. < SIDE w/ IOd NAILS, TWO NEAR EACH END OF EACH EXIST. POOL 50REWED ON(1)SIDE OF MEMBER JOIST, OTHERS 5TA66ERED w/ A DISTANCE OF !2V H (2)ROWS 3-515"TRUSSLOGK SCREWS® 24'o.G. P, BETWEEN NAILS IN A HORIZONTAL LINE. SCREWED ON(1)SIDE OF MEMBER (2)ROWS 5"TRUSSLOCK SCREWS a: 12"O.G. 'THREE-PIECE � SCREWED ON BOTH SIDE OF MEMBER ]BUILT UP GIRDER � MAX.52-- THREE-PIECE GIRDERS ARE TO BE NAILED W20d 16"O.G. NAILS ON EA. SIDE w/ TWO NEAR EA. END OF EA. K (2)ROW5 5"TRUSSLOCK SGRE NS V SCREWED ON BOTH SIDE OF MEMBER PIECE, INCLUDING INTERMIDIATE JOINTS, AND W THE (2)ROWS 5"TRUSSLOCK SCREWS a. 24"O.G. BETWEEN 1/6 OTHERS 5TA66ERED W A DISTANCE OF NOT MORE L SCREWED ON E30TH SIDE OF MEMBER- a 1/4 OF A THAN 52" BETWEEN NAILS IN A HORIZONTAL LINE. EA FOUR-PIECE CIDERS ARE TO BE A55EML.ED AS 1.NOTE: S a HEADERS NOT NOTED KITH CONNECTION PATTERN ON SHOWN, AND NAILED w/ 20d NAILS AS SPECIFIED PLAN SHALL USE CONNECTION PATTERN 'A'WHEN 8"OR SMALLER FOR THE THREE-PIECE GIRDER. a CONNECTION PATTERN 'B'WHEN 10"OR LARGER P. 2.WHEN SCREKIN6 OR NAILING FROM BOTH SIDES OF MEMBER- ]FOUR-PIECE ANCHORING: OFFSET FASTENERS 1/2"FROM ONE SIDE TO THE OTHER (BUILT UP 61RDER P, GIRDERS ARE TO BE SECURELY ANCHORED TO EXIST. SLATE PATIO MASONRY PIERS, NAILED TO WOOD POSTS OR BOLTED TO STEEL COLUMNS, rn F- Z w NA I L I NO FATTERNS FOR S 11�)E LOAF,)E E�) SEAMS (10 . FLUSH SEAMS) CENTER COVERED PORCH w/ 2ND FLOOR WINDOWS ABOVE p CU NEW (5) II- "x'1- " T.J. 2.OE MIGROLLAM ILVL BM. WRAPPED w/ NEW 2"xb" G.J. a 16" O.G. w/ FASTENING RECOMMENDATIONS FOR SIDE-LOADED„ Ix AZEK (FLUSH w/BOTTOM OF C.JJ LU526 HANGERS a FLUSH MULTIPLE-PIECE MEMBERS BM. a LEDGER BOARD NAILED' E30LTED' N IN 1 Y N Q LU 2 ROWS Ibd 5 ROWS Ibd 2 V OakT ' 2 ROWS V 2 ROWS N. COMMON COMMON Ba Ts 24• BOLTS BOLTS •12"O.G. O 12"O.G. STAGGERED° O 12"O.G. O b"O.G. Two ROWS 12"D.G. THREE ROWS 12"D.G. PROJECT: BEAM SELECTION W5TL'. NAILING ° ° ° ° NEW (2) 2"x8�� BM. AS NOTED IN NOTES 1 8 5 ° ° ° ° ° ° ° NEW (2) 2"xW BM. I I I I WRAPPED w/ Ix AZEK WRAPPED w/ Ix AZEK I i PROP. REAR _ I.TOP AND BOTTOM ROWS SHOULD BE 2"FROM ED6ES (V (FLUSH w/BOTTOM OF C.JJ COVERED PORCH (FLUSH w/ BOTTOM OF G.JJ PA R I S 2.BOLT HOLES ARE TO BE THE SAME DIAMETER A9 THl:BOLT AND SHOULD BE 'THE 2' TWO ROWS 24"O.G.5TA66ERED TWO ROWS 6"D.G. COVERED PORCH FROM THE TOP AND BOTTOM Or THE MEMBER.EVERY BOLT MUST EXTEND TMR0U&H U6H'THE FULL THICKNESS OF THE MEMBER.USE WASHERS UNDER HEAD AND NUT. O O O O O O O O O O NEW (5) I- °X�I- " T.J. 2.OE NEW (2) I- "Xa- " T.J. 2.OE 5.STAGGER EACH ROW OF FASTENERS BY 12'. O o 0 0 0 0 0 0 o MIGROLLAM LVL HDR MICROLLAM LVL HDR 4.FOR A THREE-PIECE MEMBER,THE SPECIFIED NAILINE.IS FROM EACH SIDE. D.FOUR-PIECE MEMBERS SHOULD ONLY BE USED WHEN LOADS ARE APPLIED TO BOTH SIDE OF THE MEMBER. 1855 GREEN WAY EAST 6.VALUES FOR NAILING CONNECTIONS MAY BE DOUBLED FOR W O.G.OR TRIPLED FOR 4'O.G.NAIL SPAGINS. STD,NAILING FOR TOP LOADED MULTIPLE:-PIECE BEAMS: EXIST. DWELLING ORIENT, NY 19 57 (NO WORK PROPOSED WITHIN) -7.2 ROWS OF Ibd COMMON NAILS(12"O.G)FOR DEPTHS 12'OR LESS 6.a ROWS of Ibd COMMON NAILS(12"O.G)FOR DEPTHS OF 14",16' 4 16'. DRAWING TITLE: PROP. STRUCTURAL PLANS N LINO/STRAF F NO @ N I N17)0N/DOOR HEADER PROPOSED FIRST FLOOR STRUCTURAL PLAN AN NOTATION: SCALE: 1/4" = 1'-0" A - NUMBER OF bd NAILS a EA. END OF STRAPPING (2024 WFGM,TABLE 3.1,P. 189);WHEN 5TRAPPIN6 REQUIRES OVER 14 NAILS, USE SIMPSON 0516 STRAPPIN6 (OR EQUAL). B - NUMBER:OF SILL STUDS-ON FLAT(DOES NOT APPLY TO DOORS) (2024 WFGM, TABLE 3.2315,P. 2q 7) 0 - NUMBER' OF FULL HEIGHT KING STUDS a EA. SIDE OF HEADER(2024 WFGM,TABLE 3.230,P. 2a8 PAGE: ALTERNATE AS PER TABLE 3.23D, P. 2a4) A D D - NUMBEROF 16d NAILS, END-NAILED THROUGH ADJACENT KING STUD TO END OF HEADER a EA. SIDE (2024 (WFGM,TABLE 3 P. 189) 10 G E (2-PLY) - NUMBER OF JACK STUDS a EA. END OF 2-PLY HEADER (2024 WFGM,TABLE 3.22F, P. 2a4) E (5-PLY) - NUMBER OF JACK STUDS a EA. END OF 3-PLY HEADER(2024 WFGM, TABLE 3.22F,P. 2Q4) B F - NUMBER: OF 16d NAILS, END-NAILED THROUGH ADJACENT JACK STUD TO END OF SILL(5) a EA. SIDE (DOES INOT APPLY TO DOORS) (2024 WFGM,TABLE 5b, P. 1411) FASTENINO 5GHEDULE B m m DATE: 03/30/26 5 OF 5 F ROUGH OPENING FRAMING REQUIREMEN75 FOR WINDOW/DOOR OPENINGS (IN ACCORDANCE WITH WOOD FRAME CONSTRUCTION MANUAL 2018 EDITIOAll L, p Q r NEW 2 xb 8j� ��p NEW 2 xb 12 A MAX NOTATION E E R.R. a I6" O.G. y 3 iv® +� �� R.R. a 161 O.G. ROUGH A B G D (2_PLY (3-PLY F OPENING HVR� HvR) 4'-0" PROVIDE: (2) 2"xl0" HDR (MIN.) U.O.N. 6'-0" Q I 3 4 3 12 4 EXIST. DWELLING 8'-O" 12 2 5 5 3 2 5 (NO WORK PROPOSED WITHIN) aN�--:,: ==- lo -0 " 12"-0" I6 2 5 b 5 3 a FROPOSEl7 ROOF FRAM I NO PLAN SCALE: 1/4" = I'-O" I