Loading...
HomeMy WebLinkAbout8169 . Lvjvd ZONING BOARD OF APPEALS `�� ✓!. Received TOWN OF SOUTHOLD,NEW YORK --�_---- �. Phone(631)765-1809 (631)765-9064 OCT 21 ZOZ6 APPLICATION FOR SPECIAL EXCEPTION of Appeals Application No. Zoning Board Date Filed: TO THE ZONING BOARD OF APPEALS,SOUTHOLD,NEW)ORK: Applicant(s), G- bWn/ jL of Parcel Location: House No.3 Street V;:(e,-W • Hamlet All Contact phone numbers: V 1' T " 02/q /f v•3�. SCTM 1000 Section Block I Lot(s) Lot Sized Zone District ) I hereby apply to THE ZONING BOARD OF APPEALS for a SPECIAL EXCEPTION in acc//ordance with the ZONING ORDINANCE,ARTICLE ,SECTION29V_.Q SECTION-3('1) for the following uses and purposes: CO FJ S'f X0er1'0' A®P:r:f'-X--0AJ1 6 _.4Ur-M r-:t0A r Id co/V/ ��, Vyr 0rA,0 as shown on the attac ed sury /site lan awn to scale.Site Plan review[ ]IS orX IS NOT required. k A. Statement of Ownership and Interest: if"S(�re)the ovine of property known and referred to as 35r /1 C�9 (House No.,Sfreet,Hamlet) \ identified on the Suffolk County Tax Maps as District 1000,Section Block ,Lot • ,I J and shown on the attached deed. The above-described property was acquired by the owner on B. ey,The applicant alleges that the approval of this exception would be in harmony with the intent and purpose of said zoning ordinance and that the proposed use conforms to the standards prescribed therefore in said ordinance and would not be detrimental to property or persons in the neighborhood for the following reasons: . P-59. C. 'the property which is subject of this application is zoned� dxerith s consistent with the use(s) described in the CO(attach copy),or [ ]is not consistent with the CO beingfurnished for the followin reasons : g ( ) [ ]is vacant land. COUNTY OF SUFFOLK) pA � ss.: STATE OF YORK) S>gngatur f Sworn to be fo e m this l " "day of 0�Q r_ ,20 . v (Notary Publ c) Ryan R Gr(ffm ENOTARyUBLIC,STATE OFNEWPORK stration No.OIGR6376410 alified in Nassau County on Expires August 13th.2690 2� Received OCT 21 20N Zoning Board of Appeals ZONING BOARD OF APPEALS TOWN OF SOUTHOLD,NEW YORK Phone(631)765-1809 (631)765-9064 APPLICATION FOR SPECIAL EXCEPTION Application No. Date Filed: Page 2 General Standards, please answer the following as it pertains to your project: A. The use will not prevent the orderly and reasonable use of adjacent properties or of properties in adjacent use districts BECAUSE: "Oil .14(yuSi5 Ld (,&A)r-O ✓� ¢� at-jeek- #*I�gap4aaP -"W A��-*?o i4xtj t. 0 B. The use will not prevent the orderly and reasonable use of permitted or legally established uses in the district wherein the requested use is located or of permitted or legally established uses in adjacent use districts BECAUSE: 10�19 F` � 71- l Ay ADI-i57p--r gig (f�rS 0 C. The bafety, the health, the welfare, the comfort, the convenience or the order of the town will not be adversely affected by the proposed use and its location BECAUSE: leg � � r � w �� -�'�d' f�� �� .4 D. The use will be in harmony with and promote the general purposes and intent,of Chapter 280-142 BECAUSE fl lo'r-lk ®, wl� f P?A, Al E. The use will be compatible with its surroundings and with the character of the!,; neighborhood and of the community in general, particularly with regard to visibility, scale Fl and overall appearance BECAUSE: ED 0/ Jrs 'Vp�w PPTW VIV C 1 AAA t� -3�f0C- of- -f� �"' e4)49#9-000V, A/o StJ F. All proposed structures, equipment, and material shall be readily accessible for fire and police protection BECAUSE- V Y to G. The proposal shall comply with the requirements of Chapter 236, Stormwater Management BECAUSE: <1,qe fFOYA O W N/C 'e C,1,f, J WA'f6�-- t IL- f%/pT VT4 O-L oR 4WD j)0 fV C--, 5 212026 OCR APPLICANT'S PROJECT DESCRIPTION aoard ppealS (For ZBA Reference) APIAG V: Date Prepared: I. For Demolition of Existing Building Areas Please describe areas being removed: A)O RA" II. New Construction Areas (New Dwelling or New Additions/Extensions): Dimensions of first floor extension: f , Dimensions of new second floor: -L3 its af., Dimensions of floor above second level: : MA Height(from finished ground to top of ridge): S16, Is basement or lowest floor area being constructed? If yes,please provide height(above ground) measured from natural existing grade to first floor: }�L S ° ��riO*pc Ta tP P1 III. Proposed Construction Description (Alterations or Structural Changes) (attach extra sheet if necessary)- Please describe building areas: .5 -1A Number of Floors and Get ral Characte "Aics B FORE Alterations: �� " lF 1/ ,ocw1F- j G,qEnl 7t ?iiol GA�InI�� !/�►G A+ N- �/�h Number of Floors and Changes WIT Iterations:111jr J-rV;ZAq6qS ppoa r:ZpN A�JED fn (q/ W 2.S i DE B jai/iQAl ; ;*�L p OD GD f l� ��r J � /' -P 7���1Al"- W i4 jvov/bw, IV. Cal ulations of buildin areas and lot coverage (from surveyor): Existing square footage of buildings on your property: D Proposed increase of building coverage: , / °, ', e' -if_ Square footage of your lot: 00 Percentage of coverage of your lot by building area: V. Purpose of New.Construction: �!' �S?nll�yGis.• yr 1a�1 /� Coo �, q (al-AA-,- Y/1 ,J — 644Y 1JJ6 O i ZXftig Se AtVACAEV 99 LM, f ETC VI. Please describe the land contours (flat, slope %, heavily wooded, marsh area, etc.) on your land and holy it relates to the difficulty in meeting the code requirement(s): d� 1 Or J PO Please submit seven (7) photos, labeled to show different angles of yard areas after staking corners for new construction), and photos of building area to be altered with yard view. 7/2002; 2/2005; 1/2007 Received OCT 21 2026 Zoning Boala of Appeals QUESTIONNAIRE SPECIAL EXCEPTION FOR FILING WITH YOUR ZBA APPLICATION 1. Has a determination been made regarding Site Plan reviewXqu Yes No If no, please inquiry with the,ZBA office and if site plan isd,y u nay apply to the Planning Dept. at the same time so both applications can be reviewed concurrently. 2. Are ther a proposals to change or alter land contours? a. Y No Yes please explain on attached sheet. 3: Are there areas that contain sand or wetland grasses? A/0 a. 2.)Are those;At shown on the survey submitted with this application? b. 3.)Is the property b lk headed between the wetlands area and the upland building area? AA c. 4.) If your property contains wetlands or pond areas,have you q6yitacted the Office of the Town trustees for its determination of jurisdiction? Please confirm status of your inquiry or application with the trustees: and if issued,please attach copies of permit with conditions and approved survey. 4. Is there a depression or sloping elevation near the area of proposed construction at or below five feet above mean sea level? A/0 1 5. Are there any patios, concrete barriers,bulkheads or fences that exist that are not shown on the survey that you are submitting? ®, Please show area of the structures on a diagram if any exist or state none on the above line. 6. Do you have any construction taking place at this time concerning your premises? /tea% If yes, please submit a copy of your building permit and survey as approved by the Building Department and please describe: 7. Please attach all pre-certificates of occupancy and certificates of occupancy for the subject premises. If any are lacking,please apply to the Building Department to obtain copies of them. 8. Do you or any co-owner also own other land adjoining or close to this parcel? Aloe If yes, please label the proximity of your lands on your survey. 9. Please list present use or operations conducted at this parcel a�3� /✓ .JZAj - and the proposed use ➢ S �- C ���y Cv '� ex:existing single family,prop sed:same with J�'� garage,pool or oche o vacant proposed office with apa nts above,etc.) '4 r- 1'0-Ct- ';z_6 Authorized signa ure and Date Received OCT 2 1205 AGMCULTURAL DATA.STATEMENT ZONING BOARD OF APPEALS Zoning Board °f Appeals TOWN OF SOUTHOLD WHEN 7'O USE THIS FORM. The form must be completed by the applicant for any special use permit site plan approval, use variance,,,or subdivision approval on property within an.agricultural district OR within 500 feet of a farm.operation located in agricultural district:All applications.requiring an agricultural data statement must be referral to the Suffolk'County Department of Planning in accordance with sections 239= ;it dnd Z39=n of the GenerallKuiticipal Law. 1)Naive of Applicant: ; _7 _6 Address of Applicant: t Zip Al 3)Name of Land Owr or(if other than applt ant); 4)Address of Land Owner. :. r 5)Oescriptiori-of Ptopbsed Project: o v s .T Location'of Property(road and tax map umber.): A a O 10001 9L _ 7 Is.the par*'I within an agricultural district?XNo ElYes�If es A icultural District Number p - Y 8):Is this parcel actively.farmed?. No D.Yes 9) Name and address of tiny_ owner(s) of land within the agricultural district containing active farm operation(s)'located 500"feet of the.boundary of.the proposed project. (Information.may:be available through the Town Assessors Office,.Town Hall looatiori (765-1937) or from any public computer at the Town Ha11 locations by viewing the parcel numbers on the Town of Southold Real Property Tax System. Name and.Address 3. 4: 5: 6. (Please use back side of page if more than six property owners are identified) .. . . The lot numbers maybe obtained, in..advance.,when requested from the Office of the Planning Board at 765-• 1938 or theZ., oninq Board of Appeals at 765-18.09. .. . Signal a of Allpficant Date Note: 1.The local board will'solicit'com ients fiom•the owners of land identified above in order to consider the effect of the proposed action on their farm operation.Solicitation will be made by supplying,a copy of this statement.. 2:Comrhents returned to the local board will be taken into consideration as part of the overall review of this application. 3. The clerk to the local bosrd is respotisibI6 for sending copies of the completed Agricultural Data Statement to the property owners identified above.The cost for mailing shall be paid by the applicant at the time the application is submitted for review.Failure.to pay at such time,means the application is not complete and cannot be acted upon by the board. 1-14-09 Page 9—Use Variance Application,Revision Nov.2023 vkec- OCT 1 ZM Board of Zoninsz Appeals Application Zoning Board of Appeals OWNER'S AUTHORIZATION (Where the Applicant is not the Owner) residing at � (Print property owner's name) �(Mailinj Address) do hereb a thorl (Agent) cf to apply for avian on my behalf from the Southold Zoning Board of Appeals. By signing this document,the Property Owner understands that pursuant to Chapter 280- 146(B)of the Code of the Town of Southold any variance granted by the Board of Appeals shall become null and void where a Certificate of Occupancy has not been procured, and/or a subdivision map has not been filed with the Suffolk County Clerk,within three (3)years from the date such variance was granted. The Board of Appeals may, upon written request prior to the date of expiration,grant an extension not to exceed three(3) consecutive one (1)year terms. IT IS THE PROPERTY OWNER'S RESPONSIBILITY TO ENSURE COMPLIANCE WITH THE CODE REOUIRED TIME FRAME DESCRIBED HEREIN. Ak 1 -0 ( wner's Signature) (Dated) Ryan R Griffin NOTARY PUBLIC,STATE OF NEW PORK (Print Owner's N Registration No.01GR63764W Qualified in Nassau County 0 Commission Expire,August 13th,263_ A4751i e-044 /o Revised 12/30/2025 . ,� Received �� . � OCT 21 2026 Zoning Board of Appeals APPLICANT/ N TRANSACTIONAL DI SURE FORM The Town of Southold's Code of Ethics prohibits conflicts of interest on the cart of town officers and employees.The purpose of this form is to arovide information which can alert the town of possible conflicts of interest and allow it to take whatever action is necessary to avoid same. YOUR NAME: (Last name,first name,middle initial,unless you are applying in th name of someo a else or other entity,such as a company.If so,indicate the other person's or company's name.) TYPE OF APPLICATION: eck all that apply) Taxgrievance Building Permit art Trustee Permit Change of Zone Coastal Erosion Approval of tY)t ��M�,/ Mooring er activi �y Planning Do you personally(or through your company,spouse,sibling,parent,or child)have a relationship with any officer or employee of the Town of Southold?"Relationship"includes by blood,marriage,or business interest."Business interest"means a business,including a partnership,in which the town officer or employee has even a partial ownership of(or employment by)a corporation in which the town officer or employee owns more than 5%of the shares. YES NO If you answered"YES",complete the bala ce of this form:71A date and sign where indicated. Name of person employed by the Town of outhold Title or position of that person Describe the relationship between yourself(the applicant/agent/representative)and the town officer or employee. Either check the appropriate line A)through D)and/or describe in the space provided. The town officer or employee or his or her spouse,sibling,parent,or child is(check all that apply) A)the owner of greater that 5%of the shares of the corporate stock of the applicant(when the applicant is a corporation) B)the legal or beneficial owner of any interest in a non-corporate entity(when the applicant is not a corporation) C)an officer,director,partner,or employee of the applicant;or D)the actual applicant DESCRIP: N OF RELATIONSHIP %H Ryan R Griffin Submitted this d y of 001 ' ,20V NOTARY PUBLIC,STATE OFNEWYORK Registration No.OIGR637641© Qualified in Nassau County Signature r— Commission Expires August 13th,2030 Print Name l Received. OCT 21 2026 AGENT PRESENTATIVE TRA ONAL DISCLOSURE FORM Wing Board of Appeal$ The Town of Southold's Code of Ethics prohibits conflicts of interest on the part of town officers and emolovees.The purpose of this form is to provide information which can alert the town of possible conflicts of interest and allow it to take whatever action is necessary to avoid same. {� YOUR NAME : �f t/10 �' (Last name,first name,middl initial,unless you are applyingin the name o omeone else or of a entity,such as a company.If so,indicate the other person's or company's name.) TYPE OF APPLICATION: heck all that apply) TatjZxievance Building Permit arianc Trustee Permit ge of Zone Coastal Erosion . Approval of Plat Mooring Oth (activity) Planning Do you personally(or through your company,spouse,sibling, parent,or child)have a relationship with any officer or employee of the Town of Southold?"Relationship" includes by blood,marriage,or business interest."Business interest" means a business,including a partnership in which the town officer or employee has even a partial ownership of(or employment by)a corporati n in hich the town officer or employee owns more than 5%of the shares. YES NO If No,sign and date below. If Yes,complete he balance of his form and date and sign where indicated. Name of person employed by the Tow of Southold 91 Title or position of that person Describe the relationship between yourself(the applicant/agent/representative)and the town officer or employee. Either check the appropriate line A)through D)and/or describe in the space provided. The town officer or employee or his or her spouse,sibling,parent,or child is(check all that apply) A)the owner of greater that 5%of the shares of the corporate stock of the applicant(when the applicant is a corporation) B)the legal or beneficial owner of any interest in a non-corporate entity(when the applicant is not a corporation) C)an officer,director,partner,or employee of the applicant; or D)the actual applicant DESCRIPTION PF RELATIONSHIP ENOTARYPUBLIC, yan R Griffin Submitted this day 1' ,2 STATE OFNEWYORK iion No.OIGR637641Q Signature ed in Nassau County _ �i xpires August 13th,2� Print Name /�/�/��� Received Short Environmental jefflnlegt Form ��A Part 1 -Project I ormation �— Instructions for Com In eting Zoning Board of Appeals r� Part 1—Project Information.The applicant or project sponsor is responsible for the completion of Part 1.Responses become part of the application for approval or funding,are subject to public review,and may be subject to further verification.Complete Part 1 based on information currently available.If additional research or investigation would be needed to fully respond to any item,please answer as thoroughly as possible based on current information. Complete all items in Part 1.You may also provide any additional information you believe will be needed by or useful to the lead agency;attach additional pages as necessary to supplement any item. Part 1—Project and Sponsor Information Name of Action or Project: 355 Bayview Project Project Location(describe,and attach a location map): 355 Bayview Drive, East Marion, NY 11939/ 1000-037.00-01.00-007.000 Brief Description of Proposed Action: Proposed to construct additions & alterations to existing single-family home; convert to (2) family use only for Special Exception per Article III Section 280-1313(1). Name of Applicant or Sponsor: Telephone:516-513-8838 Michael Arato/ Captain Permit p E-Mail:info@captainpennit.com Address: 535 Broadhollow Road, Suite B-16 City/PO: State: Zip Code: Melville NY 11747 1. Does the proposed action only involve the legislative adoption of a plan,local law,ordinance, NO YES administrative rule,or regulation? If Yes,attach a narrative description of the intent of the proposed action and the environmental resources that ❑ may be affected in the municipality and proceed to Part 2. If No,continue to question 2. 2. Does the proposed action require a permit,appro�1 or funding from any other government Agency? NO YES If Yes,list agency(s)name and permit or approval: Ij 1 own of Southold Building/Zoning Department ❑ 3. a.Total acreage of the site of the proposed action? 0•32 acres b.Total acreage to be physically disturbed? 0 acres c.Total acreage(project site and any contiguous properties)owned or controlled by the applicant or project sponsor? 0•32 acres 4. Check all land uses that occur on,are adjoining or near the proposed action: Urban ❑ Rural(non-agriculture) ❑ Industrial ❑ Commercial Residential(suburban) ❑ Forest ❑ Agriculture ❑ Aquatic ❑ Other(Specify): ❑Parkland Page�of SERF 2026 eived 5. Is the proposed action, NO N/A a.A permitted use under the zoning regulations? OCT 2 1 ZON b.Consistent with the adopted comprehensive plan? 6. Is the proposed action consistent with the predomirtg,�gq'tih�a M he existing built or natural NO E landscape? 7. Is the site of!7v- ion located in,or does it adjoin,a state listed Critical Environmental Area? O YES If Yes, identify: 8. a.Will the proposed action result in a substantial increase in traffic above present levels? O YES b.Are public transportation service(s)available at or near the site of the proposed action? c.Are any pedestrian accommodations or bicycle routes available on or near site of the proposed action? 9:Does the proposed action meet or exceed the state energy code requirements? O YES If the proposed acti ill exceed requirements,describe design features and technologies: 10. Will the proposed action connect to an existin publi rivate water supply? NO YES If No,describe method for providing potable water: fat 11.Will the proposed action connect to existing wastewater utilities? NO YES If No,describe method for providing wastewater treatment 12. a.Does the site contain a structure that is listed on either the State or National Register of Historic rJO, YES Places? b.Is the proposed action located in an archeological sensitive area? 13.a.Does any portion of the site of the proposed action,or lands adjoining the proposed action,contain NO, YES wetlands or other waterbodies regulated by a federal,state or local agency? b.Would the proposed action physically alter,or encroach into,any existing wetland or wat body? If Yes,identify the wetland or waterbody and extent of alterations in square feet or acres: 14. Identify the typical habitat types that occur on,or are likely to be found on the project site. Check all that apply: ❑Shoreline ❑Forest NP Agricultural/grasslands ❑Early mid-successional ❑ Wetland ❑Urban. ASuburban 15.Does the site of the proposed action contain any species of animal,or associated habitats,listed NO. YES by the State or Federal government as threatened or endangered? AAV 16.Is the project site located in the 100 year flood plain? _` O YES 17.Will the-proposed action create storm water-discharge,either from point or non-point sources? NO YES If Yes, Will storm water discharges flow to adjacent properties? ❑NO❑YES Will storm water discharges be directed to established conveyance systems(runoff and storm drains)? I Yes,briefly describe: ❑NO❑YES ..max Page 2 of 4 I 18.Does the proposed action include co struction or other activities thaRSO&VAWundment of NO YES water or other liquids(e.g.retention ond,waste lagoon,dam)? If Yes,explain purpose and size: WIT 19.Has the site of the proposed action or an adjoining property been ion ot an active or closed NO YES solid waste management fad ity? If Yes,describe: 20.Has the site of the proposed actin or an adjoining property been the subject of remediation(ongoing or NO YES completed)for hazardous waste? If Yes,describe: VT I AFFIRM THAT THE INFORMATION PROVIDED ABOVE IS TRUE AND ACCURATE TO THE BEST OF MY KNOWLEDGE IC��4�A/ 2-6 Applicant/sponsor name:/9,46C � � /�� Date: Signature: Part 2-Impact Assessment. The Lead Agency is responsible for the completion of Part 2. Answer all of the following questions in Part 2 using the information contained in Part 1 and other materials submitted by the project sponsor or otherwise available to the reviewer. When answering the questions the reviewer should be guided by the concept"Have my �I responses been reasonable considering the scale and context of the proposed action?" - No,or Moderate .Y small to large impact impact may may occur occur 1. Will the proposed action create a material conflictwith an adopted land use plan or zoning regulations? 2. Will the proposed action result in a change in the use or intensity of use of land? 3. Will the proposed action impair the character or quality of the existing community? 4. Will the proposed action have an impact on the environmental characteristics that caused the establishment of a Critical Environmental Area(CEA)? 5. Will the proposed action result in an adverse change in the existing level of traffic or affect existing infrastructure for mass transit,biking or walkway? 6. Will the proposed action cause an increase in the use of energy and it fails to incorporate reasonably available energy conservation or renewable energy opportunities? 7. Will the proposed action impact existing: a.public/private water supplies? b.public/private wastewater treatment utilities? IS. Will the proposed action impair the character or quality of important historic,archaeological, architectural or aesthetic resources? 9. Will the proposed action result in an adverse change to natural resources(e.g.,wetlands, waterbodies,groundwater,air quality,flora and fauna)? i Page 3 of 4 i �� 4 ecelved OCT No,or Moderate small to large Appea Board ls of r � impact impact Zoning r„ fits; may may occur occur 10. Will the proposed action result in an increase in the potential for erosion,flooding or drainage problems? 11. Will the proposed action create a hazard to environmental resources or human health? Part 3-Determination of significance. The Lead Agency is responsible for the completion of Part 3. For every question in Part 2 that was answered"moderate to large impact may occur",or if there is a need to explain why a particular element of the proposed action may or will not result in a significant adverse environmental impact,please complete Part 3. Part 3 should,in sufficient detail,identify the impact,including any measures or design elements that have been included by the project sponsor to avoid or reduce impacts. Part 3 should also explain how the lead agency determined that the impact may or will not be significant.Each potential impact should be assessed considering its setting,probability of occurring, duration,irreversibility,geographic scope and magnitude. Also consider the potential for short-term,long-term and cumulative impacts. I ❑ Check this box if you have determined,based on the information and analysis above,and any supporting documentation, that the proposed action may result in one or more potentially large or significant adverse impacts and an environmental impact statement is required. ❑ Check this box if you have determined,based on the information and analysis above,and any supporting documentation, that the proposed action will not result in any significant adverse environmental impacts. Name of Lead Agency Date Print or Type Name of Responsible Officer in Lead Agency Title of Responsible Officer Signature of Responsible Officer in Lead Agency Signature of Preparer(if different from Responsible Officer) Page 4 of 4 Town of Southold _ LWRP CONSISTENCY ASSESSMENT FORM deceived " A. INSTRUCTIONS OCT 2 1 2026 Zoning rsoard of A�p� for 1. All applicants for permits* including Town of Southold agencies, shall complete this proposed actions that are subject to the Town of Southold Waterfront Consistency Review Law. This assessment is intended to supplement other infonnation used by a Town of Southold agency in making a determination of consistency. *Except minor exempt actions including Building Permits and other ministerial permits not located within the Coastal Erosion Hazard Area. 2. Before answering the questions in Section C, the preparer of this form should review the exempt minor action list, policies and explanations of each policy contained in the Town of Southold Local Waterfront Revitalization Program. A proposed action will be evaluated as to its significant bene fie ial-arid-adv-er-se-effects-upon-the-eoastal-uea-( eh-includes-all-af-Southold ---- 3. If any question in Section C on this form is answered "yes", then the proposed action may affect the achievement of the LWRP policy standards and conditions contained in the consistency review law. Thus, the action should be analyzed in more detail and, if necessary, modified prior to making a determination that it is consistent to the maximum extent practicable with the LWRP policy standards and conditions. If an action cannot be certified as consistent with the LWRP policy standards and conditions,it shall not be undertaken. A copy of the LWRP is available in the following places: online at the Town of Southold's website (southoldtown.northfork.net),the Board of Trustees Office,the Planning Department, all local libraries and the Town Clerk's office. B. DESCRIPTION OF SITE AND PROPOSED ACTION SCTM# 07 - - The Application has been submitted to (check appropriate response): Town Board ❑ Planning Dept. Building Dept. ❑ Board of Trustees ❑ 1. Category of Town of Southold agency action(check appropriate response): (a) Action undertaken directly by Town agency(e.g. capital construction,planning activity, agency regulation, land transaction) ❑ (b) Financial assistance (e.g. grant, loan, subsidy) (c) Permit, approval, license, certification: Nature and extent of action: ° Locatict VALn. C pea 0 \s Site accroea geo\ Pp . T('re ent land use: t\)C r N ( nra Present zoning classification: W O ' 2. If an application for the proposed action has been filed with the Town of Southold agency, the following information shall be provided: (a) Name of applicant: (b) Mailing address: ly b t12Tl �®00 (c) Telephone number: Area Code,(rj��—� / -- (d) Application number, if any: Will the actin be irectly undertaken, require funding, or approval by a state or federal agency? Yes ❑ No If yes, which state or federal agency? 0\%EVELOPED COAST POLICY Policy 1. Foster a pattern of development in the Town of Southold that enhances community character, preserves open space, makes efficient use of infrastructure, makes beneficial use of a coastal location, and minimizes adverse effects of development. See LWRP Section III—Policies; Page 2 for evaluation criteria. Yes No Not Applicable Attach additional sheets if necessary Policy 2. Protect and preserve historic and archaeological resources of the Town of Southold. See LWRP Section III—Policies Pages 3 through 6 for evaluation criteria ❑ Yes ❑ No ❑ Not Applicable Town of Southold,NYs` �j ' http://ecode360.com/print/SO0452?guid=5163472&children=truc Received OCR � 1 2026 rd of Appeals °fl�ll9 goa Town of Southold,NY Monday,November 27,2oi6 Chapter 280. Zoning Article XXV SS ecial Exce tion Uses [Added 1-to-1989 by L.L. No.1-1989] § 280-139. Purpose. The provisions of this article are designed to provide for administrative review of selected types of proposed land uses. Certain uses which are allowable under zoning are nevertheless so likely to significantly affect their surroundings that they require individual review to assure compatibility with existing land use patterns, community character and the natural environment before being permitted to come into existence. Similarly, certain authorized uses may take on such diverse forms in their actual implementation that it is wise to review and pass upon the adherence of each individual proposal to standards and guidelines previously established for the use involved. Finally, the case-by-case review achieved by use of the special exception approval mechanism can increase the flexibility and appropriateness of local development review and better enable local officials to avoid negative consequences which sometimes arise from the otherwise lawful development or use of a particular site. § 28o-140. Special exception uses; approval required. [Amended 11-24-1992 by L.L. No.22-1992] There is hereby created a category of land use approval to be known as"special exception uses. Said uses may not be commenced, created, undertaken, carried out or thereafter maintained or substantially expanded without a special exception approval first having been obtained therefor,which special exception approval shall be granted for the use by the Zoning Board of Appeals according to the provisions for the particular special exception use set forth in this article or elsewhere in this chapter.Any land use, including the erection, construction, reconstruction, alteration, demolition, moving, conversion or change of use of any structure, shall be a special exception use requiring a special exception approval if the text of this chapter or the use schedule hereof denotes the use as being either the subject of a special exception approval or simply a special exception use. No building permit for any such special exception use shall be issued until the required special exception approval shall have been granted for the same and the conditions imposed in such approval as prerequisites to a building permit,if there be any,have been met. § 280-141. Application; hearing; approval; violations of conditions. A. An application for a special exception approval shall be on the form for the same provided by the Zoning Board of Appeals and shall be submitted in triplicate to the Zoning Board of Appeals, which shall review the application for completeness and conformity with this chapter. The Zoning Board of Appeals shall reject the application if it is not complete or not in conformance with the Zoning Code I of 11/21/20163:21 PIN ' Town of Southold,NY Received http://ecode360.com/print/SO0452?guid=5163472&children=true OCT 21 2026 and shall notify the applicant as to the reason for such rejection. If the application is satisfactory,the applig6jj f dnb1g/0�9I&f Appeals shall set the application down for a public hearing.The fee for a special exception shall be$400,as set forth in §280-i49. [Amended 4-io-i990 by L.L. No.4-1990;12-ii-i990 by L.L. No.29-i990;9-5-1993 by L.L.No.i9-i9931 B. Prior to taking action on any special exception use,the Zoning Board of Appeals shall schedule a public hearing within 45 days after determination that the application is complete. Within 6o days following the close of the public hearing,the Board shall render a decision on the application. [Amended 6-i5-i993 by L.L. No.i0-i9931 C. Effect of approval.A special exception approval issued in accordance with the provisions of this article shall authorize only the special exception use for which the approval is granted. No use which is not a special exception use hereunder shall be authorized by any such approval. The approval may include reasonable conditions which the Zoning Board of Appeals determines to be necessary or appropriate to ensure that the applicable general and specific standards and safeguards set forth in this chapter for the use can and will be met and/or adhered to. A special exception approval shall be valid for a period of six months but may be extended for one additional six-month period by the Zoning Board of Appeals within the requirement of new public notice of hearing. A continuing or permanent land use authorized by a special exception approval, which use is undertaken or begun during the period of validity of such approval,shall thereafter be deemed a lawful use as if the same were permitted by this chapter without need for a special exception permit;provided,however,that: [Amended 6-i5-i993 by L.L. No.i0-i9931 (I) All conditions imposed by the special exception approval shall continue to apply unless they, by their express terms,are of limited duration. (2) All conditions imposed on special exception approval uses generally or specifically by this chapter shall continue to apply, regardless of whether any such conditions were expressly incorporated into the special exception approval. (3) The Zoning Board of Appeals shall retain continuing jurisdiction over the same. D. Violations of conditions. A violation of any limitation or condition of a special exception approval or of any provision of this chapter applicable to a special exception use shall constitute a violation of this chapter. The Zoning Board of Appeals shall retain jurisdiction and shall have the right, after a public hearing, to modify, suspend or revoke such approval or any term or condition thereof or to impose thereon one or more new conditions,all on the following grounds: [Amended 6-i5-i993 by L.L. No.to-i993] (1) False statements or mistake of material fact: materially false or inaccurate statements in the application, supporting papers or supporting testimony or ignorance or misunderstanding of a material fact by the Board,which fact, had it been known to the Board at the time of its review, would have resulted in a denial of the approval sought. (2) Noncompliance with the terms and conditions of such approval: failure of the applicant- permittee to comply with any conditions or terms of the approval. (3) Activity beyond such approval:exceeding the scope of the activity,use or project as the same was described in the application. § 280-142. General standards. [Amended 6-i5-1993 by L.L. No.i0-i9931 No special exception approval shall be granted unless the Zoning Board of Appeals specifically finds and determines the following: 2 of 11/21/2016 3:21 Pi` Received_*t\�O��/ htt //ecode360.com/ rint/SO0452?Quid=5163472&children=tru( Town of Southold,NY P� P b OCT. 2 12026 A. That the use will not prevent the orderly and reasonable use of adjacent properties or of properties in adjacent use districts. Zoning Board of Appeals B. That the use will not prevent the orderly and reasonable use of permitted or legally established uses in the district wherein the proposed use is to be located or of permitted or legally established uses in adjacent use districts. C. That the safety,the health,the welfare,the comfort,the convenience or the order of the Town will not be adversely affected by the proposed use and its location. D. That the use will be in harmony with and promote the general purposes and intent of this chapter. E. That the use will be compatible with its surroundings and with the character of the neighborhood and of the community in general,particularly with regard to visibility,scale and overall appearance. F. That all proposed structures, equipment and material shall be readily accessible for fire and police protection. G. That the proposal complies with the requirements of Chapter 236,Stormwater Management,or in the alternative, the Zoning Board of Appeals shall condition such approval on compliance with the requirements of Chapter 236,Stormwater Management. [Added 2-14-2012 by L.L. No.3-2012] § 28o-143. Matters to be considered. In making such determination,consideration shall also be given,among other things,to: A. The character of the existing and probable development of uses in the district and the peculiar suitability of such district for the location of any of such permitted uses. B. The conservation of property values and the encouragement of the most appropriate uses of land. C. The effect that the location of the proposed use and the location that entrances and exits may have upon the creation or undue increase of vehicular traffic congestion on public streets, highways or sidewalks to assure the public safety. D. The availability of adequate and proper public or private water supply and facilities for the treatment, removal or discharge of sewage, refuse or other effluent (whether liquid, solid,gaseous or otherwise) that may be caused or created by or as a result of the use. E. Whether the use or the materials incidental thereto or produced thereby may give off obnoxious gases,odors,smoke or soot. F. Whether the use will cause disturbing emissions of electrical discharges,dust, light,vibration or noise. G. Whether the operation in pursuance of the use will cause undue interference with the orderly enjoyment by the public of parking or of recreational facilities, if existing or if proposed by the Town or by other competent governmental agencies. H. The necessity for bituminous-surfaced space for purposes of off-street parking of vehicles incidental to the use and whether such space is reasonably adequate and appropriate and can be furnished by the owner of the plot sought to be used within or adjacent to the plot wherein the use shall be located. I. Whether a hazard to life, limb or property because of fire, flood, erosion or panic may be created by reason of or as a result of the use or by the structures to be used therefor or by the inaccessibility of the property or structures thereon for the convenient entry and operation of fire and other 3 of 4 11/21/2016 3:21 Ply Town of Southold,NY t http://ecode360.com/print/SO0452?quid=5163472&children=true ergency apparatus or by the undue concentration or assemblage of persons upon such plot. Jed Wh r the use or the structures to be used therefor will cause an overcrowding of land or undue C� IIo�§t"e tration of population. K. W Z * the plot area is sufficient, appropriate and adequate for the use and the reasonably of*`rg 'DO anticipated operation and expansion thereof. L. Whether the use to be operated is unreasonably near to a church,school,theater,recreational area or other place of public assembly. M. Whether the site of the proposed use is particularly suitable for such use. N. Whether adequate buffer yards and screening can and will be provided to protect adjacent properties and land uses from possible detrimental impacts of the proposed use. O. Whether adequate provision can and will be made for the collection and disposal of stormwater runoff,sewage,refuse and other liquid,solid or gaseous waste which the proposed use will generate. P. Whether the natural characteristics of the site are such that the proposed use may be introduced there without undue disturbance or disruption of important natural features, systems or processes and without risk of pollution to groundwater and surface waters on and off the site. § 28o-144. Additional conditions and safeguards. [Amended 6-15-1993 by L.L. No.io-1993] In deciding on any application for a special exception use, the Zoning Board of Appeals may impose such conditions and safeguards as it deems necessary or appropriate to preserve and protect the spirit and the objectives of this chapter. 4 of 11/21/2016 3:21 PN T � .FORM NO. 4 ` lq TOWN: AF SOUTHOLD .BUILDING DEPARTMENT Received Office of the Building Inspector Town Hall, o C r 1 2o2s Southold,. N.Y. Zoning Boara of Appeals ' PRE EXISTING CERTIFICATE. OF OCCUPANCY No_ 2-22732 Date__- NOVEMBER 18, 1993 THIS CERTIFIES' that the building ONE FAMILY DWELLING Location. of Property - 355 BAYVIEW DRIVE EAST-MARION, N.Y, House; :No. Street Hamlet t County Tax Map No. 1000 Section 37 _Block__ ...1 Lot 7 Subdivision Filed Map No.. Lot No. conforms substantially to the Requirements for a One :Famly Dwelling built Prior to: APRIL 91 1957 ,pursuant to which .CERTIFICATE OF OCCUPANCY NUMBER 2-22732._ dated NOVEM]IM 18- 1993 . was issued, and .conforms to all, of the;.requirements. of the.applicable. provisions of the law. The occupancy for which -this certificate is issued is ONE 7AMI1Y.DWE3Z-ING`WITS 1.M,GARAGE_UNDER HOUSE The certificate. is issued to,, .PETER -G'. BREUER` (owner} of the, aforesaid building. SUFFOLK COUNTY DEPARTMENT OF `HEALTH-APPROVAL -It A .UNDERWRITERS CERTIFICATE-NG. N/A. PLUMBERS CERTIFICATION DATED; N/A *PLEASE SEE ATTACHED INSPECTION; REPORT`. ul ing Inspector Rev. 1/81 i d® Town of Southold Rece11/24/2015 P.O.Bog 1179 53095-Main'Rd, !� y�Q� Southold,New York�1971 OCT 2 r ZOZ 6 ard_of _ a Appel/s CERTIFICATE OF OCCUPANCY No 37926 Date: 11/24/2015 THIS CERMUS:that the building RESIDENTIAL.ADDITION Location of Property,: 355 Bayview Dr,East Marion $crfm#: 473889- Sec/BlocWLot 37-1 7 a Subdivision; Filed Map No. Lot No. conforms substantially, to the Application for Building Permit heretofore filed in this office dated 9/30/2014 pursuant to which BuddingPern itNo. 39254 dated 10/7/2014 was issued,and conforms to all-of the regwrements.of the.apphcable.prov sions of the-law The occupancy for wlueh tlus certificate is.issued is ADDITIONS AND ALTERATIONS INCLUDING REAR:DECK TO:AN EXISTING:ONE FAMILY DWEL',LMG AS APPLIED The certificate is issued` o Breuer,Peter of the aforesaid:building SUFFOLK CO TV OF HEALTH APPROVAL ELECTRICAL 10ERTOTCAT,k NO. 39254 1049-20 15 TWOEW CERTIFICATION DATED` A ed gmur Received OCT 21 2026 BUTHM.,DING DEPARTNIENT VINOF SOUTHOLD Zoning Board 'of, Appeals SOUTHOLD,N.Y. NOTICE OF DISkP.PRONTAL DATE. September 3.2026 TO; Michael Arato(Breuer) 535 Broadhollow Rd,Suite 13-16 Melville,NY 11747 Please take notice that your application dated September 15,20.25; 'For permit:.to construct additions and alterations to an existing single-fainfl.r dwelline to be a two-family dwelling,and to leg sheds under 144 s L j�_ at: Location of,pr'operty: 355 Bavyiew Drive. East Marion,NY County Tax Map No. 1000—Section 37 Block 1. Lot .7.1 .Is returned herewith and.disapproved on the following grounds: The posed cons_tqqjiLpn op this nonconforining 22.033 K.& Igt jit the R40-Dist rict, is riot permitted.pursuant.to Article XXXVI Section 280-207A(l)(c),which,.states;"'the gross floor area shall not exceed the permitted square footage calculated as follows:Lots containing up to 30.000 square feet of lot area 3'50 squarq-f 10/o of the lot area in excess of 20,000 square feet up to a total of 4.350 square feet maximurni".The'Permitted gross floor area is 1553).3 sq.ft.and, the —roposed gross floor area is 3.77:1.46 qq�ft. Furthennord.the-existing 10.1'k]2.P shed.is nofpermitted pursuant to Article 111.Section 280- 1.5,-Which states lots measuring 20,000-39,999 sq ft in size must...hav e.rear and side yard setbacks of 10-feet I The shed has a side yard setback of 4.5 feet. Additionally.the existing 8.2'x.12' shed is not permitted pursuant to 290-1.5 which requires all accessory I Structures to be located in the rear vard. This shed is located in a vard other than a rear-yard. In addition, the proposed Avo-fandly diielling r-equires special exception approval fivm ZBA as per Arlicle III Secuon.280-13B(]). V Authorized Signature Note to Applicant:Any change or deviation to the above referenced.application may require'.further review by the Southold Town Building:Department. CC: file,Z.B.A. r a �" ��¢� 4'��r...+�" �. �:1 +'�i` a�' � � �",) �� `al �/l`� tY a4 •.'E et { re�, f-Fr r ,Y„r' e� a ay,t !+.ili ,.� ..ram ��°4� 't ''� �/ ik o•'Ati �3 �a�j�•�S Y-M t A`y`.,► 3 ,, 1`i e r-ti� * ,�q6 �,4 `�� 7 ,�� t�`� s ya 7 1 � l; 1 ` t F i ` Sri ^' �i •yAl��r'f`-��r ii { ! A , ,q �C+ B I��+ ..1 � 1 IT + � • LL { �Z1A. �� L d j�, ( � 1 I •�'� 6 �+ lam. �• � S p. I • ,alq �^wx,t.�3`�j•.'y�t�� 6 � ��k.J 4"r r �`✓ '�y 1 ` - -.r r r Y CC#-r C2"4487 Received COUNTY CLERK'S OFFICE OCT 21 2026 STATE OF NEW YORK Zoning Board of App eals COUNTY OF SUFFOLK I, VINCENT PULEO, Clerk of the County of Suffolk and the Court of Record thereof do hereby certify that 1 have compared the annexed with the original DEEDS recorded in my office on 6/11/1993 under Liber D00011632 and Page 768 and that the same is a true copy thereof, and of the whole of such original. In Testimony Whereof, I have hereunto set my hand and affixed the seal of said County and Court this 10M0/2025 2:35:05 PM SUFFOLK COUNTY CLERK VINCENT PULEO SEAL co . sstt R. _.. luelaa M.C.Lt.Y,lam.1111411ar,aoarsi fib Ywt rY►r+iw,e,Moon Q+o++w'+Mu.InL[[l hd w CNrwNIM i,tAn "+ ' G'e1r1AT ttexlt unwuf t1MOr Aelwq net► .. fuse tillfllYlMlMy bN0111�'N �M its eltll/ . 31758 TW VaNuf[m made tilt of March .aiaeteen bundled tied ni nety three 1119TVAM CHARLOTTE E. BREUER, as surviving tenant by the entirety, residing at.305 Bayvie►+ Drive!, East Marion. NY Party of the am Pon,and PETER G. BREUER, resitting at;305 Bayview Drive, East Marion. NY Rece11/e Party of the aeeoad VA OCT 2 j 2026 Wf f liii RM that the party of the aret pQarr,to cco ildentlan of Ten Dallas and other valuable cowideratlon paid by the party of the remd pan,does hetsby grant and release unto the pan,of-the tecond part.the hart on and or suettos "Mrs of thi party of the second part'forever, ALL1hat artsfn�ta� br�., of land.Ids the'buRdltrsa.nd improvements ttoavoo erected.slttuts, Zoning Board Of qpp@aj$ sting aodbdegCHito11 oft East Merton in the Town of Southold. County of Suffolk, State of New York, which plot is known as and by the-lots numbers one hundred four 000 and one hundred 005) and one!hundred six (106) as shown on a map .entitled "Map of Section Two 6ardinor's Bay Estates, situate at East Marion Long Island" which map was filed in Suffolk County Clerks Office on September 23rd, 1927. under the number 275. Subject.to Covenants, Easements and Restrictions of record. Being and intended to be the same premises as in Liber 3302 Page 554 and Liber 4228 Page 153. Sublf+ct to a life estate in favor of.the grantor herein. This is a correction deed to correct the middle initial of the grantee which was incorrectly referred to as Peter- 3.1Bheueh and should have been Peter G. Breuer In deed dated September 14. 1992 in fiber 11649 Page $65. � G.- rc f � uui 11 t94S strict ��Ell r�x 1000 Section TOGETHER with all-fight.title and interest,it any,of"-tie party,of 1be-arse��►paert in add to a+y-streete•sad 03700 toads abutting the above described premives to the center firm thereof;TOGETHER with the 111+"punenuiep and all the estate and rights of the_party,of the ant pan in and to n14,0 mmfeeal-TO HAW AND;TO Block 1101.1)the pren the'.party of the WWWl port forever.h%es i+ercin Qionted;unto the party of the second part.the°hairs oe.aixrnao»and YtiBtn of 0100 AND The roily of the brit port eoverunts that the,potty of the Ora pert has not done or suffered"anything -Lot wherthy the,+aid.0senlisps have been encumbered in any way whatever,except sa aforodd. 003.000 4ND Ito party of tie first Part,in compliance-with'Sectiom 13 of the lean Law;covermis.ihat the patty of i the firet part wilt nv6ve the consideration for this conveyaw and"will hood the right to receive eatrh consid- era)lon III is fund to ose be applied first tar the ppuurp ot,payinr the eastof the impravent"I and will apply 007.000 thd.Wits arst to the pa)n+ant of lWeast of The improvement before using any pail o the he told of the,unc for Vpurpother ose: , e avrd pill .riuR he construed as it lir read"panies"whenever the sense of this Indenture so requires.. -IN plF,the party of'JM_arse:pact has duty exsauhd W4 and the day and year ant stwre written. 1w MYLNcis or; CCH-ALOTTE-E. BREUER' a_ am etr SUFFOLK IN HATI eo WW vam eownv 00 gar day of. March t9.92 .Eelon me On the i day of 19 .below me 'Pervaidly am Pelhonally CAM CHARLOTTE E. UER to eir known to be a j indirldind dwfibed in told who to MR Illidwn to be"the individual dtltNhed in end who elgaehuted the fo Ra inlu nm"L W adinowledded flat exeeak tht for Imlrltmenk and adrnowledted that eieewted MUM "leafed tat war, o ary ruol IC ({ram QAIlr Mk,MMiII pl�eM i Na m"k dTAf1 eK NIM►r0if.t.Ot111/1<q wl Sm"at MW van.COUNT v ee ur. Oft the day of 19 ,before m. On the 1 day of 19 t,./ore me Perto me known,who,bet b me dii swam,did de thePer a tUy rune Y y polo sad the aubserlbillg witnew to the fetegalyf imtnuneet, with say flue hw eaMau o. CC: IBDM -RDMY-EDKB-EHVGb me duty that he is the _ of y. � in and whleh,nteeated the le elie corporation described ta`°� 'INN r-----.— tYgoing insmuntem.that he 2� { �I to'be the IfldiWdad knows the eal of said rbrporulon: that the wax affixed da ��— ,N r11e exedtted the feeteft Inttrumrnt: to said instrument is sur'4 Corp me oat: that It was so tha vY_' wribing1wlmese,"wrt presem and saw Affixed by Order of the board of directors of Bald gorporo• .e the ndle:and that he,old witrrm, tine,ad 44 he signed It flame Owego by Uko order. at the.acne time subsedbd h name as witews thereto.- Received OCT 212026 Zoriiriy Board Of Appeals W11H COVRNANt�AAGAINII C hkota'I ACII, elf t;lON TITta Nix ILOCK LOT BREUER COUNTY Or TOWN TO nuorded At Ratwel of BREUER PWAatartr hnoem orewvarpm.riRewYork' 1111TUAM ST.MAIL TO ITNw,1ea rely Q•wM'tOM salve a;"M wl_ ww"M u Gary Manner Olsen, Esq. First A►serrieae70:/nauraneeCompany- P..O.,Box 706- 4&v York Cutchogue; NY.1:1935 FIrnAherlo Title Inituronw_Company- Z to Vf 1: r fi - � q S t OWNER -- STfZEET VILLAGE , LAGS DIST U.B. LOT- ire+°`r ' F��, 1=(31MER C7Wt "I R N' AGR. S /... TYPE OF BUILDING RESu t SEAS: VL. FARM I COMM. CB. Iv1IC5 Mkt: Value 'LAND j IMP, TOTAL � � DATE REMARKS � /{� ' a eV f# p � sir ,-1' i l�ftf, ':. `' '�. "' y ;' '" 1 �'°, t.,l, AG1=, �. BUILDING CONDITION N NEw I NORMAL, BELOW A13OV FARM-, Acre Value, Per Value - 7�.», N Acre i Tillable ° FRONTAGE ON WATER wailan_� •_ _ -- -- -- --. (]) ,= c FRONTAGE ON ROAD g: / - DEPTH Meadow land I �.. - __ .. _..... House P{ot N �, .BULKHEAD Total- ... DOCK :. „ a. i " G©LOR 7 711 i t , � j a t 37-1-7 01/201517 t-- 1 _ M. BIC j Extension - t , - I l tit 11 Extension I � '- I Extension -j- _ d - _ Foundation . B6:th � irretfe Porchµ °i ' a ,' - i ement j � .�`F -floors , �-, �< iC _ -�z , }nterfot Ti r_<Y LF2. Porch . A ells w Fire :Place w DR': BreezewayId H'eat � ii' - Gcirac�: � hYP,. � s }P.00ms 1st. Floor T e'•Roof - Retreat ton `Room ` Rooms 2n I^Floor i f 9 �Dorrrer, ,� !Dr`'ivew�ry a Totaly. _ W6 x E '�.- .�-� -.t . -:_ ; - � � .- =�� Ali®® �iiii��ii®®®il�il®®i■ o o. ®i® ��®■®®�i��i■®�iiirii■ .__ ■111 � .__ _ � ®■ice■■i■®®iii�l■®■ ° �° : •° - lii■®iiii��� il�i��■®�I�®riii��i JI MEAN iiii®i■ ®i■®®®i®®® MEN ®ii®iii■■iii■®iii■®Ili®®®riiii�i • °� •• • „ Ext. Walls • -a` Fire.Place Heat 1 IWood stove Rooms •• Driveway it u SURVEY OF g1°2g'50"� Received LOTS 104- 106 N .00' ed MAP OF 46 OCT 1 zozs SECTION TWO GARDINER'S SNf9 LOT 101 FQiN ` 6'" 3�uTRaL 2253 1 � Zoning Board of Appeal3 BAY ESTATES z2 29 Zo FILED ON SEPTEMBER 23, 1927 (5 AS MAP No. 275 FE 1.5E N O� SI TUA TE FED•9-E EAST M ARI ON , TOWN OF SOUTH OLD SUFFOLK COUNTY, NEW YORK t9 TAX No. 1000-03700-0100-007000 SCALE 1"=30' 3t- JANUARY 23, 2026 00 21 S83°14'1 ,r AREA = ±22,033 sq. ft. 0 F�` °' OE t0.506 ac. 'N HOUSE'' ? 146. 10) 21.f2 s'wOO11FENCEo LOT \ 0'N LOT 106. REPLACE X19.09 W FE 0 sL 9 ��� ^� 0.61S \ �9TF W " Te y 16.67 XCL16.12 cA �hN O� FE 1.4E \ 20.78 17 SEA f S f LOT I � W.ly 620.1 fly1¢s.% o\ 19 4' 1&66 // o � 1 o, ACO 00 SPRY ,y9 p8/ �6 �6J M 15-- WW S Uq�Gf / I CL14.770 ND S OONC 191 \ \2a �0 .1 w Ave t59.0 0 \ FE 0.3'EASPHALDR1AT W.W W.1„ 33?' 19 b �� �/ E STD 0' 10 0 1' J L�T* I w XCL13.91 q7 _/� OF P ^ ll � XCL1a92 LEGEND: v_.V1 �� _I C�R °yr LAMP POST �l V?96�rq " XCL1µ4!59 XCLia.24 I � � A — — — OVERHEAD UTILITY WIRES UTILITY POLE ® MANHOLE TREE SIGN CONC. MONUMENT NOTES: 1. ELEVATIONS ARE REFERENCED TO N.A.V.D. 1988 DATUM EM ELEC. METER EXISTING ELEVATIONS ARE SHOWN THUS: o�oo AERIAL LAND SURVEYING D.P.C. NOTES: LOCATIONS AND EXISTENCE OF ANY SUBSURFACE UTILITIES AND/OR STRUCTURES NOT READILY VISIBLE, ARE NOT 53 PROBST DRIVE CERTIFIED. THE CERTIFICATIONS HEREON ARE NOT SHIRLEY, NY 11967 TRANSFERABLE. PHONE: 833-787-8393 ANY SYMBOLS SHOWN ARE NOT TO SCALE AND ARE FOR E-MAIL: SURVEYSOAERIALLANDSURVEYING.COM INFORMATIONAL PURPOSES ONLY. WEBSITE: WWW.AERIALLANDSURVEYING.COM THIS SURVEY IS SUBJECT TO ANY EASEMENT OF RECORD AND ANY OTHER PERTINENT FACTS WHICH A TITLE SEARCH MIGHT DISCLOSE DISTRICT:1000 LOT:007.000 BLOCK:01.00 SECTION:037.00 *UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY MAP BEARING A MAP/FILE NO.: 275 SECTIOND72099,SUBDM9O1 Z OF SEAL IiHE NVIOLATION W YORRK STAEnEDUCATION LAWr 'Copies from the original of this survey map not marked with an original „ , „ of the land surveyor a inked seal or his embossed seal shall not be MAP OF: Section Two Gardiner s Bay Estates considered a valid true copy.* •Certification indicated hereon signify that this survey was prepared In accordance with the existing Cade of Practice for Land Surveys adopted by the New York State Association of Profeslonal Land Surveyors. Said certifications shall run only to the TITLE NO.: N/A person for whom the survey Is prepared. and an his behalf to the title company, governmental agency and lending Institution. Certifications are N MAP FILED DATE: SEPTEMBER 23, 1927 not transferable to additional institutions or subsequent owners.' COUNTY TAX MAP ID: 1000-03700-0100-007000 SITUATED AT: EAST MARION, TOWN OF SOUTHOLD SUBDIVISION MAP LOT & BLOCK S: LOTS 104-106 riN ,p W_ Lt.O COPYRIGHT DOUR HEIL, v � f-f Charlene Lea and Peter Breuer AERIAL LAND SURVEYINVEYIN G, D.P.0 U JOB NO.: 26_558 DATE: JANUARY 23, 2026 LAND pop, i Received ��q �L � „ E REVISION BY N B I 028 5 PROPOSED 2 STY Z 0 N I N G A N A L I S Y S Zoning Board of pp alr GENERAL MOTES 46 .00, DECK/BALCONY 8N 2. LARGE SCALE DETAILS SHALL TAKE PRECEDENCE OVER SMALLER SCALE DRAWINGS. .6N 225 S.F. EACH FLOOR PROJECT NAME: 355 BAYVIEW DR. 1. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. SHED LOT 101 ONCE FE , 3,SPUT RA11- ...-- .53 ) '' nn PROPOSED SITE ADDRESS: 355 BAYVIEW DR. EAST MARION NY 11939 3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS & CONDITIONS AT THE JOB AND THE ARCHITECTS OFFICE MUST BE NOTIFIED 22 29 / un BASEMENT EGRESS WINDOW MUNICIPALITY: TOWN OF S 0 UTH 0 LD OF ANY VARIATION FROM THE DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS. FE 4. CONSTRUCTION SHALL COMPLY WITH ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, RULES AND REGULATIONS. 0'1W - ���� '0 5. CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY BRACING, SHORING AND PROTECTING ALL WORK DURING � � 3 �. TAX MAP: � W � CONSTRUCTION, AGAINST DAMAGE, BREAKAGE, COLLAPSE, DISTORTION AND MISALIGNMENT IN ACCORDANCE WITH APPLICABLE ° FE 1.5E O DIST: SECTION: w 0 >_ � 20 CODES, STANDARDS & GOOD PRACTICE. C j p., PROPOSED 2 STY ADDITION (� BLOCK. LOT. � o >. m 6. THESE PLANS HAVE BEEN PREPARED IN ACCORDANCE WITH THE 2020 IRC, 2020 NYS UNIFORM CODE AND 2018 IECC. j FE 0 9,E 84 4.1 SQ.FT EACH FLOOR 1000 0 3 7.0 0 01 .00 007.001 z o Lu W v- 7. APPLICABLE NATIONAL STANDARDS WHEN APPLIED 'TO THIS WORK SHALL BE VERIFIED TO BE INCORPORATED BY REFERENCE O,, ZONE: RESIDENCE (R-40)W��UNFINISHED BASEMENT Q Q LO IN THIS STATES BUILDING CODE. m W 8. OWNER AND CONTRACTOR SHALL BE RESPONSIBLE: FOR TIMELY NOTIFICATION OF THE ARCHITECT RELATED TO CHANGES, JOB CONDITIONS OR ANY CONFLICT WHICH EFFECTS THIE SERVICE OF THIS ARCHITECT. r PERMITTED USE(S): SINGLE FAMILY U Lco LO O �� sy O PROPOSED FIRE PLACE 9. THE CONTRACTOR ASSUMES FULL RESPONSIBILITY FOR WORK OPERATIONS AND SAFETY FEATURES RELATED TO CONTINUITY Gj Ea. OF SURFACES, RAILINGS, PLACEMENT AND SWING (OF DOORS, MATERIAL, SIZE, QUANTITIES ORDERED AND INCORPORATED IN o CONSTRUCTION. r0 as O� PROVIDED 10. THE CONTRACTOR SHALL PREPARE:, SUBMIT, ADHERE TO AND COORDINATE AN APPROVED WORK PROGRAM. ASNE� (930, AREA OF LOT (TOTAL): 22,033 S.F. 11. SUBSTITUTIONS MAY ONLY 13E MADE WITH THE APFPROVAL OF THE OWNER OR HIS AGENT AND WITH NOTIFICATION OF THE 101 10 10 E AREA OF HOUSE: 2,085.26 S.F. ARCHITECT ) H SE FE 0.2'E �` AREA OF REAR DECK: 476 S.F. 12. EACH CONTRACTOR SHALL COOPERATE, COORDINATE, SCHEDULE AND CONTROL HIS WORK WITH ALL TRADES WHO's WORK 6.4'N ( 1 4 6. 1 0 ADJOINS, CONNECTS OR INTERFACES WITH HIS OWJN AND WORK TOWARD THE HIGHEST STANDARDS OF EXCELLENCE AND 21.12 6'W00 FENCE LOT 103 I PA AREA OF SHED 1 : 10 0.8 6 S.F. WORKMANSHIP. .0'NLn 00 13. ALL EXISTING SPACES SHALL BE KEPT CLEAN, CLEEAR, ACCESSIBLE AND USABLE DURING CONSTRUCTION AND PREMISE C) %� LAC X AREA OF SHED #2: 125.46 S.F. .� LOT 1 6 a 19.09 SHALL BE BROOM CLEANED AT THE END OF EACHi WORK DAY. Wq�Wgy °p a SLq� I1 6'S AREA OF EXISTING LOT COVERAGE: 12.78%/ 2,787.58 S.F. 14. MATERIAL STORAGE OR PLACEMENT SHALL NOT EXCEED LOADING CONDITIONS FOR ANY SPECIFIC LOCATION. VERIFY 1�0 W KWgy ` 16.67 xCL16.12 CONDMONS WHEN IN DOUBT. cq 6 N .�� PROPOSED ADDITION: 844. 1 S.F. 'vr P.O.B. � 15. GLASS WHICH IS WITHIN 18 OF A FINISHED FLOOROR PLATFORM, OR WHEN LOCATED OVERHEAD, SHALL B .% E TEMPERED OR ni �NCe WOOD , PROPOSED SECOND FLOOR BALCONY: 225 S.F. SAFETY. FE 1.4E `�' �� '20.78 1 SDK & Oa '; �620.18 N r4 PS LO 5� �' ® PROPOSED TOTAL LOT COVERAGE: 17.5%/ 3,856. 68 S.F. ; , � ' ( ti 16. ALL EQUIPMENT SPECIFICATIONS, INFORMATION, WARRANTIES AND GUARANTEES, ARE To BE PRESENTED TO THE OWNER IN A ] / /" ; M 6 c� . co / /'/ o ^ �..�... r CLEAN, USABLE MANNER UPON COMPLETION OF THE WORK. cx, q NEW lg 4' 66 /� 1 1 r 4`h ,. .'.:, N 5 DD1T10 % � �� / GROSS AREA APPLICABLE TO MAIN BUILDINGPROPOSED . ;'� '� `% ' 17. SMOKE DETECTOR SYSTEMS TO BE HARDWIRED AN INTER ALARMED. C,A a N ?� '�h� o ; 16g8 N STO ry' J6 0 ( ) EXISTING •f ,.s ;_, •-J �, poSE ' SQ.F M No Use�'Y `� B19 0$ �36 f� 18. CONTRACTOR SHALL ARRANGE FOR ALL NECESSARY PERMITS AND INSPECTIONS INCLUDING THE CERTIFICATE OF COMPLETION, T z.. ... ._.. / './ ; , 1s3s5 �qR �i' X GROSS AREA FIRST FLOOR: 2,085.26 S.F. 2,9291.36 S.F. AND ANY NECESSARY ASSOCIATED FEES. �� 0' 20.4 %j/ � 2• '`�� UNCFR E S CON CL14.77® 6• 9 ` '; " RC 9.o GROSS AREA SECOND FLOOR. 0 S.F. 844. 1 S F. 19. SITE PLAN DATA IS AS INDICATED ON SURVEY PROVIDED BY OWNER AND SHALL PREVAIL. SITE PLAN BY ARCHITECT IS \ 23 \�' o ��� Wq q/iV f5 ® `•` 0'; I.IE'"= ,. PURELY SCHEMATIC. \ 19� p3E ���� O '`�Q104 �8.?' "`� 98eM� CC ASPHALT GROSS AREA (TOTAL): 2,085,26 S,F, 3,773I 6 S.F. � 3SA N o \ W 33?' 19�8 ,86 WRIVEWAY VT :, W. �( ►qr q� B 33� /STONE VISUAL INSPECTIONS & VERIFICATION Rq�� �� v7 ''' e(►Rs R/Ck M ,� °� E Rq O �` `^ E �o' e BPS & 10�' 9.58 I R SETBACKS (APPLICABLE TO MAIN BUILDING) REQUIRED PROPOSED a � °�. THESE DRAWINGS REPRESENT ASV ACCURATE DIMENSIONAL REPRESENTATION OF XCL1 .21 \� \ J I ) ' ' -C (Dti d' EXISTING CONDITIONS. THE ARCHITECT AND OR HIS REPRESENTATIVE(S) MADE .��� �.� / / ) PRIMARY FRONT ( DOGWOOD LN): 40 57.08 NO CHANGE L .= T- o .� A VISUAL INSPECTION OF THE PREMISES ONLY. NO DESTRUCTIVE INVESTIGATIONS l /T Rq�L �_ - r L T 1 / �,, > > Q `- WERE MADE AS TO THE EXISTING CONSTRUCTION. OWNER SHALL BE RESPONSIBLE d� �, XCL13.91 SECONDARY FRONT( BAYVIEW DR): 25 2�I .83 >, c >- I -�- FOR THE FUTURE SAFE USE ANTD MAINTENANCE OF THE PROJECT & DWELLING. 1 o . I SIDE YARD: '/ > `� C "' \ 93SA � � 15 16.8 16.3 C. o � o �` co GENERAL CONTRACTOR AND SUB CONTRACTORS SHALL REVIEW THESE UT Rq�L °�, ' ,= M , , Cn 4- M CONSTRUCTION DRAWINGS AND ALLL DOCUMENTS UPON RECEIPT FROM THE \ �/4 Y X REAR: 50 44.5 a� Co � C ARCHITECT AND REPORT ANY ANTD ALL DISCREPANCIES INCLUDING DIMENSIONAL \ R�n J , , J }, , , CONFLICTS, FOOTINGS, FOUNDATICDNS, MEMBER SIZES, AND OTHER CONDITIONS vv/ - ' MAX HEIGHT - MAIN: 35 2 6.42 CO (0 C Fco - IMMEDIATELY TO THE ARCHITECT IFOR CORRECTIVE MEASURES PRIOR TO `� �Q XCL18.92 Co LO CONSTRUCTION. DO NOT SCALE (DRAWINGS /�' c LOT AREA: 22 , 033 S . E. NOTES: �I .T R CU SURVEYOR DATE: JANUARY 23 2026 ,�96 / 1 . ALL DESIGN IS BASED UPON OWNER-PROVIDED SURVEY DATA. (CATION Eagle Eye Land Surveying P.C. r;1 XCL1 .59 2, -- OWNER IS RESPONSIBLE FOR ITS ACCURACY & CONTENTSTAKE OUT VERIF 9 Y Y 9 T� 9 XCL13.24 PO Box 483 .� '� 3. CONTRACTOR IS RESPONSIBLE FOR CORRECTLY LOCATING PROPOSED 0 East Islip, NY 11730 "'9 p CONTRACTOR IS RESPONSIBLE F(OR CORRECTLY LOCATING PROPOSED CONSTRUCTION p, /�-- CONSTRUCTION PERIMETER AS PER DESIGN DRAWINGS PRIOR TO 0 PERIMETER AS PER DESIGN DRAWINGS PRIOR TO CONSTRUCTION BY OBTAINING & (631) 277-1726 VERIFYING ALL NECESSARY STAKIE-OUT & MUNICIPALLY-REQUIRED SETBACKS FROM �� CONSTRUCTION BY OBTAINING & VERIFYING ALL NECESSARY STAKE-OUT & Z m A LICENSED SURVEYOR. MUNICIPALLY-REQUIRED SETBACKS FROM A LICENSED SURVEYOR. rn COPYRIGHT SITE PLAN U) 1 0 z SCALE: RETIRED ASSEMBLED PARCEL(S) W z THE DRAWINGS, SPECIFICATIONS AND OTHER DOCUMENTS PREPARED BY THE 1 0 0 0 - 0 3 7 , 0 0- O 1 . O 0- 0 0 3.0 0 0 8c 007 .000 < PETER G. BREUER > O ARCHITECT FOR' THIS PROJECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE FOR USE SOLELY WITH RESPECT TO THIS PROJECT AND UNLESS OTHERWISE PROVIDED TABLE R301.2 (1) BY L - 1 1 6 3 2 P - 768 W Q THE ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS INCLUDING CLIMATE AND GEOGRAPHIC DESIGN CRITERIA THE COPYRIGHT 7. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES OF THE CREATED PARCEL(S) z z ARCHITECT'S DRAWINGS, SPECIFICATIONS AND OTHER DOCUMENTS FOR INFORMATION WIND DESIGN SUBJECT TO DAMAGE FROM AND REFERENCE IN CONNECTION WITH THE OWNERS USE AND OCCUPANCY OF THE WINTER ICE BARRIER FLOOD AIR MEAN 10 0 0 - 0 3 7 . 0 0 - 01 .0 0 - 0 0 7 .0 01 < PETER G . BREUER > I- 0 Q PROJECT. THE ARCHITECTS DRAWINGS, SPECIFICATIONS AND OTHER DOCUMENTS GROUND SPEED TOPOGRAPHIC SPECIAL WIND-BORNESEISMIC FROST DESIGN UNDERLAYMENT HAZARDS FREEZING ANNUAL BY L - 11632 P - 768 U W SHALL NOT BE USED BY THE OWNER OR OTHERS ON OTHER PROJECTS FOR SNOW LOAD DESIGN WEATHERING LINE TERMITE TEMP. REQUIRED INDEX TEMP p ,J ADDITIONS TO 'THIS PROJECT OR FOR COMPLETION OF THIS PROJECT FOR OTHERS (MPH) EFFECTS WIND REGION DEBRIS ZONE CATEGORY DEPTH WITHOUT WRITTEN CONSENT FROM ARCHITECT. I I I 1 Q Q � 20 PSF 130 NO NO NO B SEVERE 3'-0" MOD. TO HEAIVY 15• YES N/A 599 51' MAPPED : D . BECK Q C0 v 3: 6 - 12 - 2026 W � > NOTES: 0 0 W Q 1. REFER TO APPROVED HEALTH DEPARTMENT FOR SEPTIC INFORMATION F- I- W 00 2. REFER TO ENERGY REPORT MANUAL S,J,D, FOR INSULATION & MECHANICAL REQUIREMENTS. w w Ln 3. REFER TO SOIL TEST FOR ALLOWABLE SOIL BEARING AND WATER TABLE. 4. LOCATION AND E=XISTING SUB SERVIICE UTILITIES ARE NOT CERTIFIED. CODE REFERENCE cv c\l ``' "' 0 0 0 Q WW W CODE COMPLIANCE UNIFORM CODE: U) U) U 1. 2025 RESIDENTIAL CODE OF NEW YORK STATE (2025 RCNYS). 0- 0- 0 W 2. 2025 BUILDING CODE OF NEW YORK STATE (2025 BCNYS). 3. 2025 EXISTING BUILDING CODE OF NEW YORK STATE (2025 EBCNYS). O O 0 4. 2025 FIRE CODE OF NEW YORK STATE (2025 FCNYS). 5. 2025 FUEL GAS CODE OF NEW YORK STATE (2025 FGCNYS). 0 0 0 O CL 6. 2025 PROPERTY MAINTENANCE CODE OR NEW YORK STATE (2025 PMNYS). 0 7. 2020 ELECTRICAL CODE OF NEW YORK STATE (2025 ECNYS). ^ LL 8. 2025 ENERGY CONSERVATION CONSTRUCTION CODE (2025 ECCCNYS). 0- 1. - a- ILL 9. 2025 ENERGY STANDARD FOR BUILDINGS EXCEPT LOW RISE. 10. 2025 RES CHECK WEB - RESIDENTAIL DWELLINGS. _WRITTEN ENERGY COMPLIANCE STATEMENT Date: 02/02/26 THE ENCLOSED ARCHITECTURAL PLANS AND SPECIFICATIONS Scale: NOTED HAVE BEEN PREPARED BY THE UNDERSIGNED NYS REGISTERED ARCHITECT AND IN THE BEST PROFESSIONAL OPINION, KNOWLELATEST ISSUEAND BELIEF SATISFY THE CODE AND ENERGY CODE.EQUIREMENTS OF THE Drawn: BAJ/LETKOV Job: Sheet A � of - Sheets Received OCT 21 2026 REVISION BY Zoning guard Of Appeals ----- T 36'HANDRAIL IL -- UP OUTLINE OF REAR I I I I I I I DECK ABOVE � I I I I I I I --- REAR DECK - 36'HANDRAIL EL (+)3'-8" ABOVE GRADE----- 36'HANDRAIL I T F- UP ---- --- ---- ---- � IIII Q I - - -- -- - - _ ----- -- - IIII I 0 co ---- ------ - -- ---. IIII - -- --- _ W O co CO - --- II r------------------------------ -1 >- C? � .__I Z m 1 I Z 0 uj W n I < Q -I U) CO EX DEN EX. STORAGE I of v EX, KITCHEN I I �- m 1 I Q LID I I co Ln Ex ROOM I I BATH I o NC s 'o o EX. BEDROOM 3 a ,o o I KITCHEN I I ISLAND L EX, BAT I L I CL I CL. � I I EX, UNFINISHED BASEMENT I � I I I I a © HALLWAY A I I —�V 3 HALLWAY I J 36 HANDRAIL I L 6 I `r � �• C� /�_"� CLOSET CLOSET D -- _ __ U I I 36" ;fa P CLOSET CLOSET - j - - { FlPEPLACE I I -------- ---c��-�- I I I I I I L KNH I BEDROOM t EX, SITTING j I a eaeN EX, LIVING ROOM ROOM EX, BEDROOM 2 UNEXCAVATED I I � I I Cr. I ! yl - I I rI -I ff V------------------ ------- = %-----------EOUNDATION WALL (2)DH 2�4 CONC. < ---- - -- -- I BELOW 5 r o OOP OUTLINE OF CONC. STOOP ABOVE UP IROM HANDRAIL I— — _ —I y r{tlip t'V C�'�° • W E EXISTING FIRST FLOOR PLAN c� .EXISTING PASEMENT FLOOR PLAN �, r 1 SCALE: 2 SCALE: 1/8" = 1' U O Q U) r- 04 U � .0 —? 2 tCL� LO E G L - O W E V Cu LO T a) 2 L L Q i; I' � FIE, i D i`i'� -- I O -- _________--________� T 1 W rn GRAD i � GRADE GRADE GRADE ` T co L - - - - - - - - II - - - - - - - -II- - - I - - I - - - J u - rtl- I ; I U) > T = = = = � z EXISTING FRONT ELEVATION EXISTING WEST SIDE ELEVATION W W 3 SCALE: 4 SCALE: 1/8" = 1' < 00 Q I— U w OJ W Q m W 0 U F-71 � � J w OOW m (o C/) LO NNLL LO I_ -- 0 0 LIU I W W W Q a --- -- -- I--- I -------- I c) U) 000 � - - - — — — — - - -r -- — — — _ — — _ — _ _ _ _ _ _ _ _ _ _ � TF ?- -- -- -- - -- -F ';- — — — — — — — — — — — — — - - - - - - -: C� �1 TZ O GRADE O i , GRADE L - I I ► 1 I I I I I I I I W dN a Al -- �_7- - - -_-- t T>- - - - Date: 02/02/26 Scale: NOTED EXISTING REAR ELEVATION 6 EXISTING EAST SIDE ELEVATION Drawn: BAJ/LETKOV 5 SCALE: SCALE: 1/8" = 1' Job: Sheet A2 of - She I' Received F_ - -- -- OCT 21 2 6 REVISION BY FOUNDATION NOTES Zornng Board of a per - ► 75 OUTLINE OF REAR SECTION R301 — DESIGN CRITERIA DECK ABOVE ❑ FIREBLOCKING — PROVIDE TO CUT OFF TO VERTICAL & HORIZONTAL CONCEALED j DRAFT OPENINGS TO FORM AN EFFECTIVE FIRE BARRIER EXIST'G BETWEEN STORIES AND BETWEEN TOP STORY AND - - _ - DECK I ; 1 _ __L S ROOF..... [R301.1 1] I ABOVE (( ❑ DRAFTSTOPPING - USABLE SPACE IN CONCEALED AREAS NOT TO EXCEED 1000 SQ.FT. ..... [R301.12] O ❑ MIN. HEIGHT - HABITABLE SPACES & BASEMENTS NOT LESS W O `r° � THAN 7'-0.. ..... [R305.1] J Z 00 A z o � - Lo ❑ MIN. HEIGHT - NON HABITABLE BASEMENTS NOT LESS THAN 6'-8....... [R305.1] Q Q : O _ J SECTION R403 — FOOTINGS Q LO 10" 10'--0" SEE DETAIL NEW FOUNDATION CONSTRUCTION TYP. NOTE : I U LO I __ ❑ GENERAL - WALL SHALL BE SUPPORTED ON CONTINUOUS MASONRY FOR PROPOSED OR CONCRETE FOOTINGS OR OTHER APPROVED STRUCTURAL EGRESS WINDOW 8" POURED PROVIDE #5 REBAR 1'-0" LONG �- ---------------------------'� PAD FOOTING CONCRETE FND. 6" INTO EXIST. FOUNDATION WALL ----------------------J I SYSTEMS OF SUFFICIENT DESIGN TO ACCOMMODATE ALL LOADS 36"X36"X18" 1,2/ A10 8%16" POURED CONCRETE AT 12" O.C. VERTICAL SECURED I ACCORDING TO SECTION R301..... [R403.1] POURED CONCRETE PAD SPREAD FOOTING W/ HIGH STRENGTH, NON-SHRINK 1 - FOOTING-UNDER— `" I --------------------- I I I EPDXY GROUT. I z 00 8 6 I <o ► I SECTION R406 — WATERPROOF & DAMPROOF ----HOP 2 1 w l I I SON ; �` ;I-- ------ ------- ----- --------------- ---------- (3UJ U I - (2)2" 8" RIM JST ❑ DAMPROOFING - INTERIOR a• I"I C5 o I I FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE -� I ---- ----------- — --- ---- I1 -------- -- — ---------- EX. STORAGE SPACE ro I I SPACE BELOW GRADE SHALL BE DAMPPROOFED..... [R406.1) DTT2Z I I _ I I I I ENCH FOOTING 4'-0" INSTALL EGRESS I o I ( I I ' _ o cn to � 11 I I I I SECTION R407 — COLUMNS WINDOW. _OWIL2"x8" @ 12"0 J - I I I I 16'-9" I N �, � - o I AS PER R319.2 ADD FJ a zo I �� _ _ m I I ❑ WOOD COLUMNS - WOOD COLUMNS SHALLBE PROTECTED AGAINST , w I MIN STILL HT. 44" I w I I I= z- w w X 00 I ( I r_ �' z �_ �i � I " ( ( DECAY..... [R407.1] I I I I w CD- I I I ❑ STEEL COLUMNS — STEEL COLUMNS SHALL BE GIVEN RUST INHIBITIVE DTT2Z`� 11 I z I I �' o CDI I PAINT.....[R407.2] TYP FOOTING I I DN. I - - -I PAD F OTING ( I 36"X36"X18" -- w LL I I SAW CUT AND F_ 36"X3 "X18" I POURED CONCRETE II II REMOVE FOUNDATION WALL I� POUR CONCRETE PA I FOOTING I o I I� TO CREATE OPENING TO I SECTION R408 — UNDER FLOOR SPACE FOOTI G UNDER I L J w I o I I �'y '.1=_O t"il�;�(""( STL. COL. TO BE w I I= NEW ADDITION ❑ VENTILATION - UNDER FLOOR SPACE SHALL BE VENTILATED EXCEPT �`y- `--`SONOT BEEMBEDDED � oI _ I I j, o X' I N I I BASEMENTS ....[R408.1] I w I1<<.i. 4:f t - I I NEW 8" REMOVE (EXISTING - —I— —� _I I I ❑ OPENINGS - ONE VENT OPENING PERT EACH 150 SQ.FT. ..... [R408.2] `fl I WINDOW T T_ T n I I PC WALL I b I I II i z N I X i\ N I I W/ 8"X16" 00 r- I , I ( III L ! �- -I I ADD 3 LALLY & �o I N I FOOTING - I 3'-3" I 5'-1" w EX. UNFINIISHED BASEMENT � � I I SECTION R317 PROTECTION OF WOOD 1 1 1 I I I I 30X30X15 P.C. FTG. (4) t o ,k , . z ✓ r /0o I I II (SEE DETAIL) v o o� I I Tl I o _ 2X8 GIRDER FOR STAIR - = - 2"x8" (� 16"OC I) _ _ �' _� I I ❑ GROUND - APPROVED PRESSURE PRESERVATIVE TREATED ..... [R317.1.2] AD� J I I _i 1- -1 1 I 11 1 I ABOVE (, _ _ -- 1 I — -I IF- ® Cn I I SILL MATERIAL TREATED OR NATURALLY DECAY RESISTANT .... [323.11 i I 8"X16" +- — — -I I (� 11 x (D I co III II I PC FrG I b "' I I I I�- — — II I,x 0 �o \ - 1 DTT2 z I I L- - - U J -l- _ � o N o I i { l Q II III_ � c I 3Y2" DIA. STL. scM Wm i i GENERAL FOUNDATION NOTES 2 N I w w I PROPOSED I o o 11 ITz _I -_ - - _ PIPE COL. TYP. I _ ❑ DOWELING BETWEEN NEW AND EXISTING FOUNDATIONS: I -- - � -- - -�- - - (TYP.) a I _ �, I I I -1 I-I F- -- -- - - o I w p a� .�.. A7 - I UNFINISHED BASEMENT z r7 o I I 36" HANDRAIL I ��� (D d' 6 J i I 1 z II II( - __ _ _ UP PROVIDE 8 EPDXY COATED DOWELS, 12 LONG, WITH L N I I 854 sq. ft. z� -�_ - - WALLS ABOVE i a 6" MIN EMBEDMENT, SPACED 12" VERTICALLY, FILL GAPS L - � o 00 co_X X x I HT TO MATCH EXISTING I w _ II IIz —I I EXISTING (3)2"x8" CDER� REMA�I� WITH HIGH STRENGTH EPDXY MORTAR TYPICAL THREE Q c� �- N U N^, I DTT2Z II I BASEMENT o I I _ _i Im - - - - - - - - - - I I - - - - - - - CHIMNEYI- 1-J" - - - I I (3) PLACES. >+ .� >- � -III-) - I HT UNDER JOIST 6'-10" r-- - - ---1 w ;r, I I -I E�- --- -- -- - - -- - -- _ - - - I HT UNDER JOIST 6'1'10" L STACK I I c� z W — N(2)2 8 RIM J - i I Q � m- IIN 8'-4" I I I I I ❑ PROVIDE 4" MIN THICK BASE COURSE IN ACCORDANCE p �.. p ~ (B I L - ---1 - iI II` ' I I I I WITH CODE: CONSISTING OF CLEAN GRADED SAND Y � -#-5 CO CU J ( 2"x8" @ 1 6"OC .,� 2"x8" @ 16"OC a I I 2"x8" @16" O.C. 2"x8" @16" O.C. I ° z I I GRAVEL, CRUSHED STONE OR CRUSHED BLAST FURNACE W _� C° ADD FJ o ADD FJ 11 I CEI ING JOISTS TO R MAIN FILING JOISTS TO REMAIN I 1 0o H.W.H �o I I SLAG PASSING A 2" SIEVE. cn � f- cu B 0. JOIST HT. 6'- 0" I B.O. JOIST HT. 6'-10" I I i I I LO : o ( i TYP. FOOTING `i ( I co ' I I i I OIL BOILER EXIST'G - j j ❑ PROVIDE VAPOR RETARDER IN ACCORDANCE WITH L _ _ I I CODE: A 6 MIL POLYETHYLENE OR APPROVED VAPOR � co _ I MECHANICAL ® N� RETARDER WITH JOINTS LAPPED NOT LESS THAN 6" SHALL Q 20"D X36" co I I 11'-2" �, r 11'-2" co 11 `_ SONOTUBE I I `", I I I I I EXISTING 00 oo I FOOTING i i TYP FOOTING _ w - I I FOUNDATION N z� I I UNEXCAVATED BE PLACED BETWEEN THE CONCRETE FLOOR SLAB AND 6 X6 P.T. POST I 36 X36 X18 o I I I I I o I I THE BASE COURSE OR THE PREPARED SUBGRADE WHERE II II I I � NO BASE COURSE EXISTS. W/ SIMPSON - I POURED CONCRETE if z o I J ABA66Z CONN. I I FOOTING L I m I I I STL. COL. TO BE I I I O I I I II II I 1 ❑ PROVIDE J" DIA ANCHOR BOLTS AT 39" O.C. 1 ' FROM EACH CORNER. 0 INSTALL 2"X8" EMBEDDED LU m- I I OIL TANK I I / LEDGER PLATE BOLTED z I I _------� I ❑ PROVIDE A CLASS A VAPOR RETARDER UNDER ALL FLOOR CAVITES. z M WITH SIMPSON JOIST _ � ( I � � o II II I � 1 �-------------------------------------------- I I I NEW 4" P.C. I w 1 11 II HANGER LU210 I I SLAB W/ VAP. � (SEE DETAIL) co I 1 BARRIER I I i _ i I I ------------------- -------- -------------- ------- ❑ PROVIDE CRAWLSPACE VENTS AS/IF REQUIRED. l I I o I I I I ENCH FOOTING 4'-0" I I I -1 11 1 I 1 I EXISTING W Z --- I U-------- -- - ----------J I FOUNDATION W z ----- ----------- ——————— ---------------------------� (D O HOP 2816 �� HOP 2616 OUTLINE OF CONC. STOOP ABOVE —�` (4)2X8 WOOD W Q 23'-0" ADDITION 51'-2" —I GIRDER ZALL FOOTINGS ON UNDISTURBED SOIL I I Z (n 2" X 6" STL --� O Q D O U G E I R # 2 --- - -- L_ ---- LAG BOLTS �— U W 1 PR ®PO��ED BASEMENT FLOOR PLAN 0 Q Q 00 U 1/2 PLYWOOD SHEATHING �� W HOUSE WRAP OR BUILDING PAPER 3.5 STL. COL.L. —� � Of J _ FLASHING MEMBRANE ALUMINUM FLASHING O O Q ��: , , \��, 6X6 DECK POST �-- �— W m 1/2 DECK DRAINAGE GAP �,� \ 1/2 X 4 LAG SCREWS (GALVANIZED) \- \��� ABA66Z POST TABLE 402.2 LO PROPOSED BOTTOM �, \ BASE W/ 1" STANDOFF INSTALL USING (N N LL C�� 15" O.C. MAX SPACING 2X4 STUD BOTTOM PLATE SIMPSON HANGER LU210 0 16" OC 2X4 STUD WALL I 8-10D NAILS MINIMUM SPECIFf IED COMPRESSIVE STRENGTH OF CONCRETE MINIMUM SPECIFIED COMPRESSIVE STRENGTH.a(fc) W W W Q EACH FLR JOIST — 1 „ `� I CONCRETE SONOTUBE MIN. 36" BELOW mra I GRADE TYPE OR LOCATION OF CONCRETE(CONSTRUCTION (n (n (n D7 u�u Irc C, I WEATHERING POTENTIAL O O O N umiu L1 camtxfat V �g rr NEGLIGIBLE MODERATE SEVERE BASE PLATE THREADED ROD EMBEDDED LAG SCREWSn- o m INTO P.C. SONOTUBE MIN 12" AND BASEMENT WALLS, FOUNDATION AND OTHER CONCRETE NOT EXPO`9SED TO THE WEATHER 2,500 2,500 2,500` BOLTED TO POST BASE PROPOSED FLOOR JOISTS z eO�// O�// O�// O (TREATED) CONT LEDGER BASEMENT SLABS AND INTERIOR SLABS ON GRACE, EXCEPT GARAGGE FLOOR SLABS 2,500 2,500 2,500` LL LL LL (TREATED) PROPOSED SILL m Simpson Strong-Tie 3 6"X 3 6"X 18 0- FLASHING BASEMENT WALLS, FOUNDATION WALLS, EXTERIOR WALLS AND OTHHER VERTICAL CONCRETE WORK 2,500 3,000' 3,00c° (2) J" DIA X 3" LAG SCREWS Q ABA66Z (STUDS FOR DIRECT DC INTO d ° o ® EXPOSED TO THE WEATHER e,r e,t POURED D CONC. / / Date: 02 02 26 PORCHES, CARPORT SLABS AND STEPS EXPOSED TO THE WEATHEER, AND GARAGE FLOOR SLABS 2,500 3,0001 3,000° ANCHORAGE MIN. 4000LBS. Scale: NOTED FOR SI: 1 POUND PER SQUARE INCH = 6.895 kPa. a a. Strength at 28 days psi. PSI° a b. See table R301.2(1) for weathering potential Drawn: p =FER TO NYS R507.9.2 ° ° ' ° ° C. Concrete in these locations that is subject to freezing and thawing during construction shall be air—entrained concrete in accordance with footnote d. BAJ d. Concrete shall be air—entrained. total air content (percent by voluume of concrete) shall be not less than 5 percent or more than 7 percent. s °° e. See section R402.2 for maximum cementitious materials content. f. For garage floors with a steel—troweled finish, reduction of the taotal air content (percent by volume of concrete) to not less than 3 percent is permitted if Job: the specified compressive strength of the concrete is increased No not less than 4,000 psi. Sheet LEDGER DETAIL 3 DETAIL: POST PASS 4 DETAIL: COLUMN A � E):SCALE. N.T.S SCALE. N.T.S SCALE. N.T.S of — Sheets i Received CC 12 12026 REVISION BY 36" HANDRAIL Zoning Board of Appe f;a LIFE SAFETY NOTES 36" HANDRAIL SECTION R319 — EMERGENCY ESCAPE UP ❑ SLEEPING ROOMS - AN EMERGENCY ESCAPE AND RESCUE OPENING SHALL BE PROVIDED IN EACH NEW SLEEPING ROOM.....[319.1] ❑ EMERGENCY ESCAPE - BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM AREA: = 182.7 SF EXISTING REAR DECK ROOM ..... [R319.1] ❑ MIN. OPENING - 5.7 SQ.FT. MIN ..... [R319.2.1] 1- Q REQUIRED I 8% = 14.7 SF 36" HANDRAIL ( ) ' " 36" HANDRAIL NATURAL LIGHT PROVIDED = 23.77 SF+ARTIF. EL. +- 3 -8 ABOVE GRADE ❑ SILL HEIGHT - 44 INCHES MAX .. .. [R319.2.3] 0 � REQUIRED X RO = 14. SF ❑ WINDOW WELLS - AREAS NOT LESS THAN 9 SQ.FT. WITH A HORIZONTAL � W VENT AREA PROVIDED = 14.6 SF+ARTiF NOTE: WHERE LIGHT AND VENT REQUIREMENTS a PROJECTION NOT LESS THAN 36......[319.4.1]. W O CO ARE NOT MET, ARTIFICIAL LIGHT AND o ❑ WINDOW WELLS - DEPTH GREATER THAN 44" SHALL HAVE A PERMANENTLY 0- -5 Z °� C? VENTILATION IS TO BE PROVIDED Q � W - AS PER NYSRC R303 = AFFIXED LADDER OR STEPS......(R319.4.2] _Z = J ^ UP ❑ WINDOW WELLS - SHALL HAVE PROPER DRAINAGE CONNECTED TO THE BUILDINGS -' Q 0 , 5co Cn ANDERSEN 210410 - EGRESS "' FOUNDATION DRAINAGE SYSTEM.....[R319.4.3] I- O0 w LIGHT = 10.45 SF VENT = 5.83 SF - 6" SECTION R318 — Q m_ MEANS OF EGRESS STEPS 10'-0" 23' 0" ADDITION (� � EGRESS WINDOW ❑ RISERS - RISERS NOT TO EXCEED MORE THAN 8 1" HIGH......[R318.7.5.1] 10" TREATED POST WELL BELOW 2'-6" ❑ OPEN RISER: - DO NOT PERMIT PASSAGE OF 4" DIA SPHERE ..... [R318.7.5.1] \ ❑ TREADS - TREADS NOT LESS THAN 9" WIDE ..... [R318.7.5.2] ❑ HEADROOM - NOT LESS THAN 6'-8" HIGH FROM STAIR NOSING ..... [R318.7.2] UP ❑ WIDTH - 36" MINIMUM WIDTH ..... [R311.7.1] `O o o \ I I ❑ ILLUMINATION - IS REQUIRED AT ALL STAIR AREA ..... [R318.7.10] DH 5 \ ❑ HANDRAILS - REQUIRED 4 OR MORE RISERS ..... R318.7.8] (2)2X8 RIM EGR SS AW °14 ❑ HEIGHT - NOT LESS THAN 34" HIGH ..... [R320.2] U 2 2X8 HDR. (2)2X6 HDR. DTT2z 3 EX. DEN 0'-0" 13'-4" 3'-6": 5'-0" 12' 3" I - Y to I SHOWER EX. SECTION R321 GUARDS FALL PROTECTION f--(V ( l N \ EX. KI CHEN t ,t BATH [ ] N 24 N CL \ Z j YZ ❑ HANDRAILS - HEIGHT NOT LESS THAN 36' HEIGHT ..... 321.1.2 Iv z® - a • EX. \ �w / m a NEW o LAUNDRY ( ❑ FALL PROTECTION - GUARDS AND WINDOW FALL PROTECTION AS PER ..... [R321.1]] 2"x8 ' @ 16"pCDTT2Z CL BATH �o v ROOM o _ 0 50.0 sq.ft. > � I �Q i I ❑ OPENING HEIGHT - WINDOW FALL PROTECTION AS PER ....[R321.1.1] z ADD FJ a� Z © g CRICKET �' x Q w S 1—ice m o \ SHOWER ® WC N - ❑ HEIGHTS - GUARDS HEIGHT NOT LESS THAN 36" ..... [R3211.1.1] CV I NEW DECK g -X \� o o=o ^I 24 N N w \Q I li 2.24.0 sq. ft. 30 nl °„ II KITCHEN `r'n/+t '�':,, t« . I NEW BEDROOM 30 EEC. BED,I�OOM 3 \ I ISLAND yi `} C 182.7 sq. ft. C ILING HE GHT: 8'-0" W SECTION R 310 — SMOKE ALARM L I �` a# ' I X x - sc J EX. BATH / -- N � � N o� � CEILING HEIGHT: 8'-0" SC ' j LANDIN / I" INST,L CEILING HEIGHT: Q cr Co oO NEW ❑ LOCATIONS - EACH SLEEPING ROOM, OUTSIDE OF SLEEPING ROOMS, EACH N 24 \ CL `v I \ I / >N 7 -10 \ I STORY INCLUDING BASEMENTS/CELLARS AND HAIBITABLE ATTICS. c.i STAI WAY m , = - (CL. 3 MAX. FROM BATHROOMS..... [R310.3] I 3 ' HANDRAIL Ln 3'-6" °, N PROP EXIST'G EXIST'G ❑ INTERCONNECTED - ACTIVATE ALL ALARMS TO BE AUDIBLE ..... [R31 i0.4] RIDGE RI RIDGE ❑ POWER SOURCE TO BE DIRECT HARD WIRED & INTERCONNECTED ..... [R314.6] 2 _ - (D D \ Q SCM =3 A < o TT2Z o 14" TJI 560 @ 12"OC / SC HALLWAY' I — U o I� � ADD FJ - HALLWAY SECTION R31 1 CARBON MONIXIDE ALARMS (DI- � N z�'CIO N 2 2X8 _ I. W HALL Y I I Q DN 36" HANDRAIL J - ❑ LOCATIONS - OUTSIDE OF EACH SLEEPING ROOM ..... [FC 915] U O .� o x z I I I I = U ❑ POWER SOURCE - TO BE DIRECT HARD WIRED & INTERCONNECTED i" (n T- N U w N I 3'-4" 1 I I I CLOSET CLOSET = -- C } DTT2Z 1 1 1 26x68 z U EXIST'G I I > C ti L- 36" ANDRAIL CLOSE OORFILL SC SC FIREPLACE SECTION R324 — GLASS � � o t- cc 36"WIDE UL / I \ I ❑ ING WET SURFACE - HAZA Co O W .� � (2)2X8 RIM APPROVED GLAZ ( ) RDOUS LOCATIONS REQUIRE: FULLY TEMPERED J }, FIREPLACE a w o REMOVE SAFETY GLASS..... [R324] rn EICU - W a � r CRICKET tO = O / EXISTING _ Q S CLOSETS TO \ N I _I @ �/ I CREATE ca � o HALLWAY \ EX• EX. SITTING Q w N NEW LIVING NEW KITCHEN _X o Q/ F, BEDROOM 1 z 197.06 sq. ft. 208.86 sq. ft. J N Q� I EX. LIVING ROOM ROOM 20" HEARTH CEILING HEIGHT: 8'-0" <�� I V I ISC F� RAMING NOTES o g �� / I rEX BED OOM 2 0 \ - ❑ ALL STRUCTURAL LUMBER TO BE DOUG - FIR 2 MINIMUM. 0 �, C ILING HEI HT: 8'-0" w c��jJ ( - Z 3 4" ❑ PROVIDE DRAFTSTOPPING. — C0 1'-7�" - 6„ 22'-7" 2"x8" 16"OC I o a 9, 1>, Ex15 'G CJ ❑ PROVIDE CROSS BRIDGING. 00 2"x6" @ 16"O ( 2"x6" @ 16"OC o N EXIST RR EXIST RR ❑ MAX. CANTILEVER SPAN 32 AS PER TABLE R502.3.3(1). W Z N 61SHWASHERi I I I Z (2)2X8 HDR. o ❑ MAX . CANTILEVER SPAN DOES NOT EXCEED ALLOWANCE 4 TIMES =EXISTINGQ DEPTH OF JOIST. (� 0 (2)D 3 5 DH 3030 2 DH 2 CDNC• o W (2)2X HDR. STOOP ❑ PROVIDE FIRESTOPPING AS PER ....[R602.81 Q 6'-6" 11'-8' 4'-10" CD Z �_ 1 . CONCEALED VERTICAL SPACES. 23'-0" ADDITION L6_ 51'-8" EXIST'G UP 2. VERTICALLY AT EDGE OF FLOOR LEVELS 0 z W -- 3. HORIZONTALLY AT INTERVALS NOT EXCEEDING 1OFEET. — 0 W ROM HANDRAIL ❑ ALL STAIRS TO BE CONSTRUCTED IN ACCORDANCE WITH [R311 .51 & [R3111. 0 J � DOUG FIR # 2 oQ o ❑ ALL HANDRAILS AND GUARDS TO BE CONSTRUCTED IN ACCORDANCE PROPOSED aC m � WITH SECTION R312. V 1 SCALE: >- >- Q W 1 1 LEGEND � � 4Y2 6/2 0 0 W Q scot SMOKE/CARBON MONOXIDE {� m DETECTOR 1 LO Y" EXT. GD. PLY. p TOILET EXHAUST LO HEATSENSOR 6" DIAMETER N N C� WD. SHEATHING ® ENGINEERED 0 0 Q Q 2"x4" WD. STUD CEILING LIGHT W W W LUMBER @16" O.C. Y" GYPSUM BOARD ON EACH Y2 GYPSUM BOARD ON EACH P REFLECTIVE 2 10 A/C VENT RESIDENTIAL STRUCTURES WITH y' R-15 BATT. SIDE (W�" GYPSUM BO. @ SIIIDE (W�" GYPSUM BO. @ TRUSS TYPE CONSTRUCTION, 0 0 0 TOILET SIDE & TUB SURROUND) TCOILET SIDE & TUB SURROUND) PRE-ENGINEERED WOOD CL 0- 0- W CONSTRUCTION AND/OR TIMBER 0 0 0 Y" RIGID INSULATION CONSTRUCTION LEGEND CONSTRUCTION FOR NEW 9 1 W/ n/ n/ 1 LAYER Yz" GYP. 0 EXIST FOUNDATION 8•P.c DWELLING AND/OR ANY W LDL W 0- ✓� O ADDITION, ALTERATION A SIGN �- OR SYMBOL DESIGNED IN AIR INFILTRATION BARRIER 0 NEW FOUNDATION 8"P.c ACCORDANCE WITH TITLE 10 ,NE ram+TYRE BY "TYVEK" OR EQUIVALENT °T°'.n°"ATE'm' �\ Y" STROKE Date: 02/02/26 2"x4" WD. STUD Zx6" WD. STUD NYCRR PART 1265 SHALL BE T'•" A'. T'�V TO RIIMICATI TIE TIiR CONSTRUCTION @ 16" O.C. @)16" O.C. ON I EX.WALLS AFFIXED TO ANY ELECTRIC BOX UNDER SECTION�z 0EFs�`cT� CE51GNANON FOR S RUCTURAI • "� ATTACHED TO THE EXTERIOR ;°PE CONSTRUCTION° °F MUSS Scale: NOTED OF THE STRUCTURE FOR FIELD ;; F• FLOORFRAMING,AND INCLUDING VINYL SIDING (OWNERS SELECTED) 0 NEW WALL INSPECTION '� R ROOF FRAMING Drawn: BAJ » » HTTP://WWW.DOS.NY.GOV/DCEA/ STAaUU Aa1NcS FR FLOOR ANDROOF-- FACE OF STUD 4 � INTERIOR 6 � Il �1 1 E1��A1 OR '�XT RR WALL T �/T ��/A�/T /q` /m �(T T�/��/7�� � EX.PLUMBING WALL NOTICADOPT.HTML#TRUSS Job: EXTERIOR V / ► ALL — P�R 1 I®1 I I �LL _ PL�1R 1 IO1 tl I I �LL © NEW PLUMBING WALL Sheet (PLUM4BING WALL) A 4 of — Sheets i Received OCT 21 2026 REVISION BY Zoning Board of Appeals 9'-10" 23'-1" 6„ 5'-9" 14'-9" 2'-6„ E-- o AW 21114 o 2 DH 3°5° 2 2X6 HDR. 0 >- m °° 35" H NDRAIL (2)2X8 HDR. ® -j z ' M 5'-0" z J 5 . (0SHOWER Q Q (q r �-- O J W W i � CD �" m � - 1�' " NEW-2 - I 9�0 `� W U � co ' I BATH oG CD i ( _ li �II LOUNGE = 50 0 sq. 6' j I SITTING AREA NO N 1.Y I 303 sq. ft. I I3 -4' 4„ BALCONY mzc I Z I00 N = N o ( - 00 LANDING - f r_� c0 N N p r7 N 3 " ANRAL " o i DN EXIST'G � `�2x8 16" RIDGE 2"X10 @ 2" O.C. ( ;� � o ADD CJ C'i AR SPAN � o = c o o�I 00 x o I 2"x8" @ 16"OC 2"x8" @ 16"OC w v ADD R.R. scM ADD R.R. OFFICE 104 sq. ft. 3 -4" ,ZC M J ACCESS/SDOUBLE H HANDRAIL I CL / 22'-6" N AME R49 ly ADD ROOF . � 48 30 '' CRICKET L J o '� FLUE - �'-4" 30 3'-4" 30 0 N CL ^1 I o0 1 % N Q 00 4„ 4„ I N scM 48 - SCM I w U O � c (D �, M U 7'-4" 3'-9" 4'-0" 7'-1" 6' W ti CD U) U 0o I �c � Z ►� NEW BEDROOM '� NEW BEDROOM EXIST'G LO ExisT'c Cu 0 0o ROOF ROOF }' O �- j C ti I132.43 sq. ft. 133 sq. ft. I Co m � W C: I CoCn F- Cu ±' Nam = a)2 2X8 HDR. (2)2X8 HDR. ( -p c ca (2)DH 3°5° (2)DH 3°5° - Q EGR SS EGRESS 6'-9" 10'-0" 6'-9" 0 23'-6" - z M s d� U PRO �' OSED SEC0IVD FLOOR FLAN w ll z 0/ z 4•SPHERE UNABLE TO PASS THRU 4'SPHERE UNABLE TO PASS THRU (D O W Of I•- 0 z cn SECTION N 1 101 ENERGY EFFICIENCY - Q S E BALUSTERS 0 MAX. 4•U.G. GUARDRAIL SYSTEM BY SECTION R 5 0 7 EXTERIOR DECKS ! TIMBERTECH' OF f--• W EQUAL 5.WIDE ❑ WOOD MATERIALS - WOOD MATERIALS SHALL BE N0.2 GRADE OR BETTER [ R507.2.1 ]. ❑ MECH. VENTILATION - PROVIDE VENTILATION THAT MEETS SECTION M 1507 OUTDOOR AIR to TOP HANDRAIL 0 J Q INTAKES AND EXHAUSTS SHALL H1AVE AUTOMATICE OR GRAVITY "' S .X 5�. 0 Q W DAMPERS ..... [R1403.61 COMPOSE NIEWEL < POS❑ DECAY RESISTANCE - PLASTIC COMPOSITE DECK BOARDS, STAIR TREADS GAURDS SHALL ADD (2) CORINERS ADD (2)LT DDIN TO < W BE DECAY RESISTANT R507.2.2.3 ] _ z - TM� SLIM I IS —I > [ ❑ LIGHTING EQUIPMENT NO LESS THAN 75 PERCENT OF LAMPS IN PERMANENT LIGHT o a -'— _ DOUBLE RIM FIXTURES SHALL BE HIGH EFFECIIANCE LAMPS .....R404.1 N PROVIDE 4•X44• O O '" Q N i� ; SLEEVE IN POURED — L IJ m ❑ FASTENERS - M(ETAL FASTENERS AND CONNECTORS USED FOR ALL DECKS SHALL TOP O DECKING � LO \ CONCRETE FOR POSE I � BE IN ACCORDANCE WITH [ R317.3 AND TABLE R507.2.3 ] ❑ MECH. VENTILATION - PROVIDE VENTILATION THAT MEETS SECTION M 1507 OUTDOOR AIR co ��SEE PLANS (p) CCOMPPOOSt�TE — L0 DECKING/FLOORING (lYP) ` v ` V INTAKES AND EXHAISTS SHALL HAVE AUTOMATICE OR GRAVITY MIN 1> COBOTTOM MPOSITE � a& RIM FLOOR Q Q 0 ❑ FLASHING - FLASHING SHALL BE CORROSION RESISTANT METAL [ R507.2.4 1 DAMPERS ..... [R1403.6] sPINDELS (T,P) 'AZEKJOISTGOV R BY W W W Q 6•SPHERE UNABLE TO PASS THRU APPROVED EQUAL '^ ' - ❑ CERTIFICATE - A PERMANENT CERTIFICATE SHALL BE COMPLETED BY THE BUILDER 6• DIA POURED CONC SONOTUBE 000 W ❑ FOOTINGS DECKS SHALL BE SUPPORTED ON CONCRETE FOOTINGS OR OTHER OR REGISTERED DESIGN PROFESS3IONAL AND IS TO BE POSTED FOOTING UNDER STRINGERS (IYP) APPROVED STRUCTURAL SYSTEMS. THE FOOTING DEPTH SHALL ON THE WALL WHERE THE FURNACE IS LOCATED. IT SHALL NOTES: 000 0- > > 1 1 HANDRAILS AND GUARDRAILS SHALL BE ASSEMBLED AND BE IN ACCORDANCE WITH [ R403.1 .4 ] LIST THE PREDOMINANT R VALU[ES OR INSULATION CONSTRUCTED TO WITHSTAND A LIVE LOAD OF 200 Ibs. (y- INSTALLED ..... [R401 .3] CONCENTRATED LOAD IN ACCORDANCE TABLE - R.301.5. Q� n 2 GUARDS (HANDRAILS) HEIGHT TO BE NOT LESS THAN U 34• 3 GUARDS MAXIMUM SHALL BE PROVIDED THERE WALKING SURFACES Date: 02 ❑ MINIMUM SIZE - MIINIMUM SIZE OF CONCRETE FOOTINGS AS PER [ R403.1 .4 ] a ARE OFFSET VERTICALLY BY DISTANCE OF MORE /02/26 ❑ CONTROLS - AT LEAST ONE THERMOSTATIC SHALL BE PROVIDED FOR EACH THAN 30• - R321.1.1 SEPERATE HEATING AND COOLING SYSTEM ..... [R403.1 ] 3 ALL NEWLY CONSTRUCTED STAIRS, HANDRAILS AND Scale: NOTED ❑ DECK POSTS - SINGLE LEVEL DECK POST SIZE AS PER [ R 507.4 ] GUARDRAILS SHALL CONFORM TO SECTION R320 do R321 OF THE 2025 RESIDENTIAL CODE Drawn: BAJ ❑ FTG CONNECTION - SIINGLE LEVEL DE [ R507.4 ] ❑ DUCT TESTING - DUCTS SHALL BE PRESIURE TESITED TO DETERMINE AIR LEAKAGE Job: BY EITHER: A) ROUGH IN TEST OR, B) POST CONTRACTORS TEST. A WRITTEN REPORT IS TP+O BE PROVIDED TO THE LOCAL DETAIL: HANDRAIL. Sheet BUILDING OFFICIAL. ..... [R403.3i.3.] 1 A5 SCALE: 1/4" = 1 ' of - Sheets i Al�_ Received 10'-0" OCT 2 12026 REVISION BY Zaning Board of gppe RIDGE VENT (TYP) XEL+ 46.28' i' o � EXIST'G RIDGE / \ \ W p OCO -jZCOC) STAIR - - --. _ LQ_ Oa J U ENCLOSURE - Ow w BEYOND ` VENTED q- m Z' LO SIDING i SOF IT TYP. U co AW 2014 TO MATCH 11-U-L 1 LL t BANISTERS 0 4" O.C. L1L1 u LI_ll11.11-1LJ�1 1Ll _--- ----------- HANDRAIL 36" IL' LL1 II li i 1l lLL- ROOF 1 Il ill (2)DH 305° ------ HANDRAIL BOLTED CD `I TO DECK FRAME CRICKET( h EGRESS AND I N / \ RIM JOIST i — ----00NT. 2"X10" 2X8 FJ I "O.C. r. l ER / --- -- --�-0GDEfAIL _ (2)2"X8" ti v CCA (2)2X12 BEAM—/ RIM JOIST(TV) ----- - 0 0 CCA 6X6 POSTS { DH 3 5� -- (2)rx12" \ j ' EGRESS GIRDER(TYP) -- AW 2114CD �v [EXIST — __ 36" HANDRAIL o0 J DWELLING I � - - -- --SEE DETAIL LLrT .. T__. t �_ _ - -- - - -- -- FOR�T2OPO�ED Ly- LILLLLLLLLLI_LLLLI_LLLLLLLLLL�LLLLL; LLL LI LLLLLLLL L_I_I_LL LLLLLLLLLLLLLLLLLLLLLLLLLLL '_LLLLLLLLI_LLLLLLLLLLLi-_LLLLLLLLL LI LLLLLLL L_LLLLL�LLLL_Y�LL,_ EGRESS WINDOW - — IIIj +%�' � q L ..� t L_LLLLLLLLI_LLLLLLLLLLLLLLLLLLLLLi.LLLLLLLLLLLLLL_-LLLLL LLLL_LI_LLLL_I L_LLLLI I LLLL - L _LILL LLLLLLLLLLL LL LLLLLLLLLLL LLL LLLLLLLL LLLLL_LLLL'. ; LLL.; LijiLLLLLLLLLLLLLLLLLLLLL_LLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLL,I.L LL__L LLLLLLLLI I!'.' '_LLLLLLLLL L-LLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLL �LI L'(_LLLLLLLLLLL LLLi_LLLLi_LLLLLLL LL LL LLL LL LLL LLL LI.1_LLLLLLLLLLLI_LLLL_L LLLLLLLLLLL'Lt_ -LLLL LLLLL L' LLLL L_LLLLL LL LL LLLLLLLLLLLLLLLLL L LI_LLLLLLL LLL LLLL 1�2/ A10 �I-LLI LLLLL.LLL:-.-LLLLLLLLLL!_LLLLLL_LLLt-LLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLL LL iLL L'_LLLLLLLLLLLLLI_LLLLILL__LLL LLLLLL!_L LL LLLLL LLLLLLL LLLLLLLLLL CV 'ayj"� t 'LLLL LI_LL.L_LLLLLLLLLLLLLLI_LLLLLLLLI-i I _Li LLLLLLL'I I-!-LLI-LLLLLLLL LLLLLLL LLLLLLL LLLLL L'_LLLL._ILLI_LLLLLLt_LLLLL LLLLLLLLI_L_LLLLL�L _'_LLLL1LLLL.LL_'y LLLL I EL+ 20.78' E + 20.78' r " ,,I t LLL L.Lt LLLLLLL LLLLLLLLLLLL LLLL-LLLL LLLLL LLL L_L_ 1_LLLL.LLLLL -, L I-t-I _-__'_I_ - - - --- — I- LLLLL l LLL L L LLLt_L LL! LL_L L L LLL LLLLLLLLL.1 LLt LLLLLLLLLLLLLLL.LLLLLLLLLLLLLLLLLI LLLLLLLL I I '1 LLL�L._LLL LLLLLLLLLLLLLL I L LLLLLLLLLLLLLL_LLL, L LLLLLLL I-L_LLLI I LLLL[LLLL'LLLLL LLLLLL-�L I l �LLLLLL_L LLL LLLLL LLLLLLLL LLLLLLLLLLLLLLLLLL L_LLLLLLLLLLLI L I L LILL__LLL 1_'_'L LI_L__I_t _LLLLLL L 'LLL LLLLLLLLL_L_ .LLLLLL LLLLLLLLLLLLLLLLLLLLLLLLL-LLLLL LLLLLLLL LLL LLLLLLLL L_; l LLLL' LLLL L_t_LL -L STEEL REMOVABLE CHECKER I II II I O LL_LLLLLL I_i_L_L -II_Lt_I_L.LLL LLLLLLLLLLLLLLLLLLLLLLLLLLLL I_LLLLLLLLLI_L LLLLLLLLLLLLLL'. LLLL.LLLL I I J — LLLLLLLLLLLLLLI_I_LLLLLLLI L LLLLLLLLLLLLLL PLATE SAFETY GRILL ON GRADE LLLLLLLLLLLLLLLLLL 'LLLLLLLL_L LLLLLLLLLLLLLLLL._LLLL_._I_t_L L LLLLLLLLI L Lt_LL_LLLLLLI_L_ _ -L_ TYP. FOOTING GRADE LL EL+ 18.66' LLLLLLLLLLLLu I LLL L_LLLLL_LLLI_LLLLL - --- - EGRESS ESCAPE IIIL__..11Ii 20"D X36" WINDOW WELL I AllI�--JI I FOOTINGBE �_ -- �� --- - — 6„X6" P.T. POST W/ SIMPSON PAD FOOTING L_ 36"X36"X18" � ABA66Z CONN. POURED CONCRETE PAD =3 FOOTING UNDER CD .,., Co - SONOTUBE _C N � N Q (1) 04 � SCALE. ~ � p ~ 2 CIOJw �' (.0@) LO ~ N RIDGE Cl) _ _0 oI VENT "' EL+ 46.28 (TYP) Q Cu i 12 / \ a7 O 0 EXIST'G RIDGE z d) _,I - - --- ---- --- -- - - - STAIR (n >' VENTED ENCLOSURE Z SOFFIT TYP. BEYOND W� z V � HANDRAIL BOLTED BANISTERS @ 4" O.C. - - - Lu - TO DECK FRAME AND HANDRAIL 36° II Il illi II 11 '�1.I,I RIM JOIST _ —._ _.. IJ1 ----._-_-_ Illll' r [ mil]i 11 i z �- `i' o — o ° o o -- - - 11_l. iIL1I EXIST TIE IN (2)DH 3 5 (2)DH 3 5 110 EGRESS EGRESS---_-_--__ ROOF DWELLING O z < 5/4X6 COMPOSITE DECKING CRICKET O Lli 2X8 FJ 16" O.C.- - -.-- - ---- --- ------i TYP RIM JOIST -I W c ) �� - � � U w 0 0 I Q - (2)2"X12"—� DH 3 3 �__ L2 (TYP) oo e 36" HANDRAIL O O W GIRDER Q- CCA 6X6 POSTS - J - �' E- I--- W m ---- � � �_ In (2)DH 3°5° SIDING (2)DH 2845 EGRESS TO MATCH EXIST'G CN CAI LL � — ---- ---- --- - - - - -� - - 0 0 0 I.:_: - - ---- - ---- -- --- - -- -- - - - - - --- W W W 00 N I HOP 2816 HOP 28161 GRADE 000 0� Imo—SIMPSON AB66 GALV L+j . - - EL+ 20.43 EL+ 19.58 W 0- 0- W o POST BASE W/ DOA. �� O O O TYP. FOOTING �, i ANCHOR BOLT W/ 7" I 20"D X36" MIN. EMBEDMENT I W W 0- SONOTUBE PAD FOOTING FOOTING 36"X36"X18" Date: 02/02/26 6"X6" P.T. POST -- _ - - - POURED CONCRETE PAD -- --- --- --- ----- - f W/ SIMPSON FOOTING UNDER --- -- -- �� f ABA66Z CONN. SONOTUBE Scale:SEE NOTED UNDERPINNING DETAIL Drawn: BAJ Job: Sheet �� oPosE� READ �L�v� T�oiv A ("OD" of - Sheets i ROCCiv ,ed S , OCT 2 12026 Zoning goord of q ea REVISION BY RIDGE VENT (TYP) . EL+ 46.28' 1-LIp:iLL111 _u �;; ASPHALT B-1L JJII GENERAL MATER ALS ROOF 1 1#l1 Ltlu U4 1� SHINGLES 1l 1�� L11 1 ��# I— p i Q TABLE R402 . 1 . 3 PRESCIPTIVE 01- u> li Flu L L - INSULATION MINIMUM BY COMPONENT W Z m c j Q W .— ���Q� o o PROP SED Lo ❑ R-30 @ WALLS WOOD FRAME W/ V.B. OR, R20+R5 CONT., R13 + R10 CONT. z o J 2 D 5 VENTED SOFFIT Q Q - ��� O LANT RN (TYP) ❑ R-49 @CEILING FLAT ATTICS W/ V.B. OR, R38 UNCOMPRESSED OVER EAVE (R402.2.1) F-- 0 wLO ❑ R-49 @ ROOF/CEILING NO ATTIC W/ V.B. OR R38 IF < 500 SQ.FT. (UNCOMPRESS) (R402.2.2) Q m BANISTERS ® 4" O.C. i I �\� _ ____SIDING U M 4v- ���Q� HANDRAIL 36" _ — _ _ _ TO MATCH ❑ R-30 @ FLOORS W/ V.B. OR, 19 & 7.5 CONT. OR, R20 CONT. `') Ln ❑ R-19 @ CRAWLSPACE WALL W/ V.B. OR, R15 CONT. OR, R13 + R5 CONT. Y, C„ ❑ R-10 @ SLAB UNHEATED PERIMETERS TO 4 FT. ❑ R-19 @ BASEMENT WALL OR, R15 CONT OR, R13 + 5 CONT. -- - - - - -- _ -- ❑ 0.27=U @ FENESTRATION / .40=SHGC ❑ 303.1.3 U-FACTORS OF FENESTRATION _ �+ DH 3151 SED o o -- - PRODUCTS ARE DETERMINED IN �! EGRESS T RN DH 3 5 ACCORDANCE WITH THE NFRC TEST. 24" ^ 36' HANDRAIL - - ROOF CONSTRUCT - ION . __---- - _-- �_- ❑ ALUMINUM LEADERS AND GUTTERS zLLLL—Lr: �-- I - — ---- -- --.— LLLLLLLLLL i.LLLLL- LLLLLL L�LLLLLLL ___ - _____ _ ❑ 1" X 6" SOFFITS OR EQUAL LLLLLLLLLLL _LLLLL LLLLLLLLLLLLLLL" - �-' �- LLLLLLLLLL ._LL_LLL. LLLLLL_LLL L LLLLI, I I . LLLLLLLLLL _LLLLL' LL-LLL:LLLLLLLLi - , LL LLLLLLLLL_LLLLL_ LLLLLLLLLLLLLLL� N GRADE LLLL::_LILLI_ L;LI_I L LLLLLLLLLL LLyy� EL+ 20.7 ' ❑ VENTED CONTINUOUS SOFFIT EL+ 20.43' ❑ ROOF OVERHANG (SEE PLANS) SIMPSON AB66 GALV , ❑ ASPHALT SHINGLES 30 YEAR (SEE FINISH SCHEDULE) ,`` '; POST BASE W/ DOA. El 15# BUILDING PAPER ANCHOR BOLT W/ 7 MIN. EMBEDMENT (TYP.) ❑ 1/2" EXT. PLYWOOD SHEATHING �P r.• - � i f _ / ❑ 2X8 ROOF RAFTERS @ 16 O.C. (PROPOSED) --� TYP. FOOTING PAD FOOTING ❑ 9 1/4" TJI 230" CEILING JOISTS @ 12" O.C. (PROPOSED) 20"D X36" 36"X36"X18" ❑ R-49 FIBERGLASS INSULATION BATTS 18'-3" SONOTUBE POURED CONCRETE PAD 24'-10" [1 1/2" GYPSUM BOARD ALL WALLS & CLG O FOOTING FOOTING UNDER 6"X6" P.T. POST SONOTUBE W W/ SIMPSON O ABA66Z CONN. WALL CONSTRUCTION : Q � " PROPOSED SIDE ELEVATION � F � E > 2 c '� 1 SCALE: 1/4" = 1 ' 2X10 RIDGE ❑ ALUMINUM LEADERS AND GUTTERS � 0 oCo 75 RIDGE VENT ❑ 1" X 6" SOFFITS OR EQUAL M COL. TIE _I W r U� �/-- RIDGE STRAP 2"x6"@48" ❑ VENTED CONTINUOUS SOFFIT Cn � (-- ASPHALT ROOF ❑ SIDING (SEE FINISH SCHEDULE) (DT = �k8 SHINGLES 12 ❑ 15# BUILDING PAPER c 2"X10"@12" OC 7 Q CLEAR SPAN C ROOF ASSEMBLY / I oc ❑ 1 2 EXT. PLYWOOD SHEATHING (SEE TYP NOTE) El2"X6" WALL STUDS @ 16" O.C. (PROPOSED) SACE STOIRAGE ONLY SIMPSON ❑ R-20 FIBERGLASS INSULATION BATTS + R5 MTL CONNECTORS O (LIMITED) 4 ❑ 1/2" GYPSUM BOARD ALL WALLS & CLG � n( !i r r ,; l(1t11� r t)n�,; r x ti i TYP. 6" Iji(klil+1�i!(`?�111�`r4�itJ (��1(i`,}!��`i1it�1,�1!11_l!}f -111)O!}�f',,!\(i�l1�l(11, �11f1�')il� UU�;1O�`il�(f`'ii�'1/���tj�i`llt/\.(/'��(1(rS/d illi - FASCIA z 0) t` EXIST RIDGE VENTED R5 R20 14" TJI 560 SOFFIT TYP. FOUNDATION CONSTRUCTION : U) �- @ 12"OC F.J. RS R49 BANISTERS 4" O.C. - I �20 cor�T. �� �� u) HANDRAIL AD HANDRAIL 36" y CLEAR SPAN o NEW �FFICE EXIST RR ❑ 5/8 DIAM. ANCHOR BOLTS 12 LONG W Z TO DECK ` RIM JOIST _ _ NEW LOUNGE i @ 39" O.C. MAX 12" FROM CORNERS 0 �, WALL ASSEMBLY ADD LEDGER „ „ V (SEE TYP NOTE) 2"X8" CONT. EXIST( G ❑ ANCHOR BOLTS ARE ALSO TO BE PLACED 6 TO 12 W10 Q R20 Rs CUT R.R. ATTICFROM THE END OF EACH PLATE (SECT. PER 3.2.1.7) �2)2"X8" CONT. ❑ STEEL PLATES 1/2" - 3"X3"x1/2" BEARING PLATES UNDER BOLTS IM JOIST2X8 FJ 16" O).C. z ~ � ❑ 8" THICK POURED CONCRETE FOUNDATION WALLS O Z � (3)2"X10„ CJ (SDEER _ STEPS UP ADDEXISTLEDGER ❑ 8X16 POURED CONCRETE FOOTING MINIMUM (3000 PSI MIN) W GIRDER (TYP) 6 X6 POST DETAIL) 2"X8" CONT. ElAPPLY WATERPROOFING TO EXTERIOR OF FOUNDATION 0 J R5 R20 _ Z ❑ BOTTOM OF FOOTING TO BEAR ON 0 Q 0 0 o ADD WALL N EXI9ST'G CONC. STAIR ENCLOSURE W HALL LAND( G FOR STAIR x UNDISTURBED SOIL AT MIN 3 BELOW GRADE Q 00 36" HANDRAIL NEW LIVING oo FOIUNDATION U W c Q ALL ASSEMBLY ADD/GIRDER UNDER W LL _l ADD GIRDER UNDER WALL (SEE TYP NOTE) LEDGER (3)2"X8"@16"OC (3) 2"X8"@16"0.C. (SEE DETAIL) O O R30 R30 R30 ENGINEERS 0 EXIST'G FJ - m S 2X8 F.J.@16"O.C.�1x - r' �1h EER NOTE FRAMED FLOOR CONSTRUCTION . _ EXIST G F.J. LO EXISTING PC FOOTING PROP. UNDERPINNING DOWN M N --(2)2X12 BEAM LEDGER EDETAIL ALUMINUM TERMITE SHIELD NEW (4) 2"X8" TO A LEVEL OF ACCEPTABLE SOIL 8"X16" (VIF) ❑ 3/4" PLYWOOD SUB FLOOR CV CV L1- ( ) GIRDER STRATA THAT IS TO BE GRADE NEW 3.5" STL COL. DETERMINED BY A QUALIFIED o ;� EXISTING o ❑ 14" TJI 560" FLOOR JOISTS @ 12" O.C. (SEE PLANS FOR SIZE) Q 5/8" DIA. ANCHOR BOLTS o BOLTED TO .GIRDER o z SOILS ENGINEER. i UNFINISHED o AS PER CODE SEE DETAIL '- Lo o � / SIMPSON ABA66iZ GALV (SEE FOUND. NOTES) I i � BASEMENT ❑ CROSS BRIDGING @ 1 3 SPAN _ w INSTALL 36" WIDE POURED I ❑ CLASS 1 VAPOR BARRIER OVER ALL SLABS 000 �POST BASE W/ >" DIA. - PROPOSED o EXISTING CONCRETE SEGMENTS MAX. d W ANCHOR BOLT VW/ °; UNFINISHED UNFINISHED (SEE PLAN) X 24" WIDE (THICK) NEW EXISTING 7" MINIMUM EMbBEDMENT 9 MINIMUM FOOTING(S) UP TO 3" SLAB SLABCL TYP. FOOTING 10'-01" BASEMENT BASEMENT BELOW BOTTOM OF THE EXISTING O O 00 L_ 20" DIA X36" 8"X16" PC FOOTING. PROVIDE r---ADD FTG 30"X30"X15" SONOTUBE _ __ NON SHRINK GROUT AFTER 3 DAY:'S - - a- 0 PAD FOOTING — BETWEEN NEW UNDER- L PROVIDE 3" THICK FOOTING � � 2'-O' 36'X36"X18' ADD 4' xl PINNING AND EXISTING FOOTING. NON SHRINK Date: 02/02/26 POURED COINCRETE PAD LPC SLAB 2'-0 SLAB GROUT AFTER FOOTING UNIDER NEW 36"X36"X18" 3 DAYS EXISTING 8"X16" SONOTUBE FOUNDATION CONSTRUCTION CAST IN PLACE (2) NUMBER 4 STEEL REQUIRED _x CONCRETE FOOTING FOUNDATION REINFORCEMENT BARS CONTINUOSLLY EXISTING PC FOOTING Scale: NOTED 8" CAST-IN-PLACE (VIF) AND PLACE THEN A MINIMUM OF :2" UP 8"X16" (VIF) CONCRETE FND. FROM THE BASE OF THE FOOTING AS Drawn: BAJ 8"X16" CAST-IN-PLACE CONCRETE ADD UNDERPINNING NOT TO COME INTO CONTACT WITHi GRADE. D O U G f C I IR # 2 SPREAD FOOTING (SEE DETAIL) Job: EXISTING 8" CONC FOUNDATION REQ'D Sheet SECTION DETAIL: UNDERPINNING A 7 2 of - Sheets SCALE: 1/4" = 1 ' SCALE: 1/4" = 1'-0" Received OCT 21 202 REVISION BY Zoning Board of Ap eal • RIDGE o VENT N 12 \ Q7 \ EXIST'G RIDGE / — — — — — — — — — — —-- STAIR I— SOFFFITTTTYR. �— _ -- BEYOND Po C HANDRAIL BOLTED 8111 0 4'OC. Gr' TO DECK FRAME AND ---- r_ {.I.. ti RIM JEST NN+ORAI�• I J EXIST `� I (2)DH IV (2)DH 3°5°---- O r 5/4X6 COMPOSITE DECKING EGRESS EGRESS — — ROOF DWELLING OZWM Ld 2X8 FJ 16"O.C. o - — — — — — — — — — — — LO (z)z xe ( r , i RIM JOIST(fYP) j ---- `i I--� 0 �I (2)2•X12• I i ON 3°3° I j -_-� I A m W — _ 6J� GIRDER(TYP) •I 1 1 ' CCA 6X6 POSTS 38"HANDRAA_ I EGRESS TO MATCH--_— �_ - I -- -_ j -- - - — L I ch 0 t I (2)DH 3W SIDING _ (2)DH 2845 EXIST'G I - - - -- - - - - -- _ _ _-- - - - - - - - - - - - - - - — — — — HOP 2°iai HOP 2°la GRADE ') SIMPSON A866 GALV ..__ __ �.' I +i1 o POST BASE W/}'DOA TYP.EoonNc �, . .ANCHOR Bar w/7' 20'D X36' MIN.EMBEDMENT SONOTUBE PAD FOOTING I I I I I I I I FOOTING 6"x36X18" P.T.POSE 3NG CONCRETE PAD W/SIMPSON FOOTING UNDER — — — — _ _ — — — — — — — _— —_—�L�— _l _J_._ — (\•�Y\]\ ABA66Z CONN. SONOTUBE SEE 44-6" DETAIRPINNING 5T-1• �', `_(_ 4,} 1 SKY PLANE ELEVATION SCALE. 1/8" = 1' RENT (lyP) r �' 4i' 4.�- EL+46.28' RIDGE FT- ` r ASPHALT XMt ` �'4•t` �, A" r ROM sHn4GLEsi" �R,'o'�+-, aG4 (2)D 5° R � z—� Idi - - --- �VQAm SOMELANTI J tl �J N —._— C") 8W61ERS 0 4"O.C. i � i /\ _------- z --TO MATCH :3 E or'oi� - I •n �_ � —__ N V a � C� - - - - - - - - - - q N Q L) � �- (0 1 I _6" (� z r- :F: LO --- -�--,- — — — _ — — — —_ �C U) - - - - - - - - - - - - - -- I 4- (0 0) � GRADE ---==tea El+ 07 v EL+20.43. Cn SIMPSGON AB66 GALV I:: j I u' / POST I BASE W/r DOA I CoC r ^ V -F•-4 W ANCHOOR BOLT W 7' MIN.EEMBEDMENT(tYPJ I•' 16'-10• - — 7YP.77 rt�a 20"D X36" 36X36"X18• `V Q 18'-3• SODTUSE POURED CONCRETE PAD 24'-10' FOOTING FOOTING UNDER 6'X6'P.T.POST SONOTUBE W/SIMPSON ABA667 CONN O 7' T r f /J ►SKY PLANE ELEVATION 2 SCALE: 1/8" = 1' W zz r� O V � W Q b RIDGE VENT \ \ 12 O Z U) Q7 �- W EXiSrG RIDGE - - - - - - - - - - 0 J STAIR Q Q VENTED �— r ENCLOSURE M W SOFFIT TYR. ; BEYOND < W HANDRAIL BOLTED EMIS1ITb 0 4'or — TO DECK FRAME AND RIM JOIST (2)DH 3454 - - (2)DH 3°5° _- 7r. EXIST 5/4X6 COMPOSITE DECKING EGRESS EGRESS- ROOF DWELLING T — — n CRICKET 2X8 FJ 16'O.C. o — — — v-®v®- — — — — _ _ ___ _ _ ��•yy�� (2)2-XB- ( ' r '^ 1 RIM JOIST(IYR) �--- -_.----- L I i I •� I W CD Ir �1 NNLL (2)2•X12• ( 'Ofi 3°3° ---- — ;HH ' GIRDER(TYP) -m 36"HANDRAIL I --- -— —I I =_� - 1 LO `., • I CG 6X6 PoSTS 0 I I c I (2)DH 3°59 SIDING - - 5 -- -� - -4 (2)DH 'G — EGRESS — — — — —"--TO MATCH---= EXISTG I — — _— -- - --- -- I WWW U) U) U) I,. J SIMPSON AB66 GALV +,_-' +1 y 1 4I I I j l j L+ O O O 0— a POST BASE W/J•DOA NP. FOOTING ANCHOR BOLT W/7" I I� I I I I — El- 20"D X36• '� - MIN.EMBEDMENIi ( , J OTIUBE ---��pAO FOOTIN F G I _— FOOTINNG 36"X36"X18" �lT 6•X6'P.T.POST POURED CONCRETE PAD _ — — — — _ _ — — — — — — W/SIMPSON FOOTING UNDER L_L— —�� — — — — — � I _ � — �_ — — � LL ARA66Z CONN- SONOTUBE J— A SEE L3� t4•-6• UNDERPINNING 57'-1' DETAIL Date: 02/02/26 Scale: NOTED Drawn: BAJ (D- §SCALE: T PL ANE LANE ELEVATION Job: Sheet A B of — Sheets II Received ec 20 REVISION BY ON c AILS 0 6- Zoning Board of Ap ea t8d NAILS Y TABLE R301.5 TABLE R301. 7 i2-ON CENTER MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS ALLOWABLE DEFLECTION OF RATIO LIMITS = H / L < 3 , /2 °O (In pounds per square foot} STRUCTURAL MEMBERSb'C L- (SEE PLAN) TRIPLE PLYWOOD LEaani DOUBLE TOP _ PLATE CORNER - oo USE LIVE LOAD STRUCTURAL MEMBER LIVE LOAD STUD _I RAFTERS HAVING SLOPES GREATER THAN 3:12 WITH UNINHABITABLE ATTICS WITHOUT STORAGEb 10 L/180 uNE OF SECONDFf�F FINISHED CEILING NOT ATTACHED TO RAFTERS 2"x4"®16 O.C. (min) OR THIRDBOX Q UNINHABITABLE ATTICS WITH LIMITED STORAGE�9 20 INTERIOR WALLS AND PARTITIONS H 180 1/2" CDX PLYWOOD 8'-0" "�4 SHEATHING (WOODol STRUCTURAL PANEL) HABITABLE ATTICS AND ATTICS SERVED WITH FIXED STAIRS 30 FLOORS L/360 w 3 � M OD "CATS" AT MID-SPAN / J OD = 4 -0 8 -0 1 CEILINGS WITH BRITTLE FINISHES z m M a 3 SOLID BLOCKING ® BALCONIES (EXTERIOR) AND DECKSe 40 L 360 O W SEAMS 31 I/2• INCLUDING PLASTER AND STUCCO Z W LU Ln ( ) o _J 8d COMMON NAILS ® 4" _ 5TRETCH-N-5EAL STRETCH-N-SEAL FIRE ESCAPES 40 CEILINGS WITH FLEXIBLE FINISHES L/240 fa- Op J n O.C. EDGE AND 12" O.C. ° . ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° o INDOYV PAN FLASHING, WINDOW PAN FLASHING (INCLUDING GYPSUM BOARD) W I FIELD MIN. `D� GUARDS AND HANDRAIL Sd m2 200' ALL OTHER STRUCTURAL MEMBERS L/240 V M d Box WL/RIM,IST. BOTTOM SILL PLATE I n EXTERIOR WALLS-WIND LOADS° WITH PLASTER OR H 360 o CORNER ° ° ° ° ° ° GUARD IN-FILL COMPONENTS 50 STUCCO FINISH / HOLDOWN _ ° ° ° ° LOCATION 1/2" CDX PLYWOOD o a a H EXTERIOR WALLS-WIND LOADS° WITH OTHER BRITTLE m SHEATHING (WOOD olo ° ° PASSENGER VEHICLE GARAGES 50 FINISHES /240 STRUCTURAL PANEL) tea NAILS o ,z•ON coo ROOMS OTHER THAN SLEEPING ROOMS 40 d L ° ° Dee w�uLs oo e• EXTERIOR WALLS-WIND LOADS° WITH FLEXIBLE FINISHES H/120 "CATS" AT MID-SPAN / TOP-SEAL TAPE TOP-SEAL TAPE SOLID BLOCKING @ ° ° 1 -4 OVER-FLANC7E TAPE OVER-FLANGE TAPE SLEEPING ROOMS 30 LINTELS SUPPORTING MASONRY VENEER WALLSe L/600 " SEAMS "Ir 4 -0 c Note: L span length, H span height. STAIRS 40 = P 9 = P1, FIRST FLOOR WALL a. For the purpose of the determining deflection limits herein, the wind load shall Y O M AT CORNER be FOR SI: 1 pound per square foot= 0.0479 I::pa, 1 square inch= 645 mm2, 1 ASDe loads obtained from Table R301 to be token as 0.7 se component and cladding 2t2 WALL SHEATHING NAILING PATTERN 3 `-I— e4` w pound = 4.45 n. b For cantilever members, L shall be taken as twice the length of the cantilever. 1. SHEATHING AS PART OF SHEARWVALL SEGMENT WHERE NOTED a. Elevated garage floors shall be capable of supporting a 2,OCO-pound load C. For aluminum structural members or panels used in roofs or walls of sunroom ON FLOOR PLAN, SHALL BE COMTINUOUS FROM SILL TO TOP SIMPSON STRONG TIE HTT22 & LSTA 21 applied over a 20-square-Inch area. additions or patio covers, not supporting edge of glass or sandwich panels, the PLATE OR ADEQUATELY BLOCKED) AT JOINTS. g b. Uninhabitable attics without storage are those where the clear height between total load deflection shall not exceed 1/60. For continuous aluminum structural 2. HOLDOWNS REQUIRED AT ALL CORNERS OF STRUCTURE, SEE joists and rafters is not more than 42 inches, or where there are not two or members supporting edge of lass, the total load deflection shall not exceed DETAILS ON PLANS. 1. SHEATHING TO BE INSTALLED WITH 8d NAILS more adjacent trusses with web configurations capable of accommodating an L 175 for each lass ligte or g 60 for the entire length of the member, 3. REFER TO THE NAILING AND STRAPPING DETAILS FOR A 2. INSTALL PLYWOOD VERTICALLY AT ALL CORNERS / 9 / 9 „ assumed rectangle 42 inches in height by 24- inches in width, or greater, whichever is more stringent. For sandwich panels used In roofs or walls of CONTINUIOUS LOAD PATH. 3. SPACE NAILS � 6 O.C. AT PLYWOOD EDGES 9 " within the plane of the trusses. This live load need not be assumed to act sunroom addl 1 tons or patio covers. the total load deflection sholll 4. SPACE NAILS ® 12 O.C. VERTICALLY IN PLYWOOD FIELD 5TRE1C4i-N-51=AL STRETCH-N-SEALIING p concurrently with any other live load requirements. j r(�,^n WINDOW PAN FLASHINCG WINDOW PAN FLA5i- not exceed L/120. fit.'. _ 2 STORY C. Individual stair treads shall be designed for the uniformly distributed live load ,r`�'� d. Deflection for exterior walls with Interior sum A or a 300--pound concentrated load acting over an area of 4 square inches, 9YP board finish shall be limited to whichever produces the greater stresses. an allowable deflection of H/180. r ! k r'a1 - WIND BRACING HAS BEEN DESIGINED IN ACCORDANCE WITH d. A single concentrated load applied in an direction at an point along the top. e. Refer to Section R703.6.2. 9 PP Y Y P 9 P '. 4 .1 IRC SECTION R 602.10 METHOD CS-WSP & ABW e. See Section R507. I for decks attached to exterior walls. f. Guard in-fill components fall those except the handrail), baluster and panel V �d TYPICAL BRACED WALL DETAIL fillers shall be designed to withstand o horizontally applied normal load of 50 pounds TABLE R301.6 u7 r on on area equal to 1 square foot. This load need not be assumed to MWFRS (MSFRS ) act concurrently with any other live load requirement. MINIMUM ROOF LIVE LOADS IN POUNDS-FORCE PER `c, g. Uninhabitable attics with limited storage ore those where the clear height between joists and rafters is 42 inches or greater, or where there are two or SQUARE FOOT OF HORIZONTAL PROJECTION more adjacent trusses with web configurations capable of accommodating an g� WALE �j�rT p ^ c g� �T r� q assumed rectangle 42 inches in height by 24 inches in width, or greater, within Y►' ALL ►'F' 1 ND O W FL1 1►J 11..E V G D E 1 H�L the plane d the trusses. TRIBUTARY LOADED AREA IN � h. Glazing used in handrail assemblies and guards shall be designed with a safety SQUARE FEET FOR ANY � E .�. @is SCALE: 1/4" = 1 factor of 4 The safety factor shall be opened to each of the concentrated loads ROOF SLOPECALE: STRUCTURAL MEMBER OU applied to the top of the ran. and to the load on the Ids components. These loads � � 't a) shall w determined independent of one another, and loads are assumed not to 0 TO 200 201 TO 600 OVER 600 -� (D ~ L occur with any other live load. O The live load need only be applied to those portions of the joists or truss bottom chords L- U) N U FLAT OR RISE LESS THAN 4 INCHES Q where all of the following conditions ore met: 20 16 12 C �- 2 1. The attic area is accessed from an opening not less than 20 inches in width by PER FOOT (1:3) .- z ti 30 inches in len th that is located where the clear hei ht in the attic is not less Ln g g RISE 4 INCHES PER FOOT (1:3) TO > L than 30 inches. 16 14 12 2. The slopes of the joists or truss bottom chords ore not greater than 2 inches LESS THAN 12 INCHES PER FOOT (1:1) O «� p V vertical to 12 units horizontal. RISE 12 INCHES PER FOOT (1:1) — Co0) ce) 3. Required insulation depth is less than the joist or truss bottom chord member depth. AND GREATER 12 12 12 J W C V fl The remaining portions of the joists or truss bottom chords shall be CO U) co designed for a uniformly distributed concurrent live load of not less than 10 pounds For SI: 1 square foot= 0.0929 m2. 1 pound per square foot= 0.0479 kPo, co LO � ~ a)BRACED WALL LINE TINI In[LSIY SHFATHFn per square foot. 1 Inch per foot= 83.3 mm/m. = L- E3RACED WALL LINE _ C Q cu 0 RETURN PANEL BRACED WALL PANEL AT HOLD DEVICE BRACED WALL PANEL AT Z DID OF BRACED WALL LINE END OF BRACED WALL LINE O 1/3 OF SPAN 1/3 OF SPAN 1/3 OF SPAN _ co it 'e1 3 OF SPAN 113 OF SPAN 113 OF SPAN Ea CONDITION END CONDITION 2 Q O N, NOTCHES OR HOL S / / / 1/4DEPTH PERMITTED 1/3DEPTH NO NOTCHES �- OF JOIST OF JOIST OR HOLES IIISIY L LINE DAMAGED PIP ("U PERMITTED U Z BRACED WALL LINE BRACED WALL LINE NOTCHES NO GREATER 0 1/4 OF DEPTH PENETRATION GREATED ct O Z THAN 25% DEPTH OF THAN 2 DI CD LLJ STUD. OF DEPTH 2 W � O OF JOIST /�- Q (n PROVIDE A MINIMUM OF 2" -- I LJ N OTC H ES NOT PERMITTED SEPERATION BETWEEN ,>a�v � Z n 1LIJ HOLES AND NOTCHES NOTCHED ARE NOT PERMnTED c- Cr rn RETURN I U I N THE SAME LO CATI 0 N FROM EACH OTHER AND IN THE SAME LOCATION AS HOLES I� ° O Z "+ PANEL ( n j FROM THE ENDS OF FIRST BRACED v AS HOLES MEMBERS O 48" MINIMUM BRACED WALL PANEL FIRSWALL BRAG (n I -- W AT END OF BRACED WALL LUNE *SEE REQUIREMENTS z LU RAFTER / CEILING JOIST 0 (S) — OD—CONDITION 3 END CONDITION 4 I O I F BORED HOLE IS J z = BETWEEN 40% AND 60% Q UJ JI InI ISI Y SHFATHFn REQUIREMENTS OF THE STUD DEPTH < m 0 �eBRRkCED WALL LINE N ' PROVIDE STEEL ANGLES TOP AND BOTTOM _ RETURN PfWEI: 24• FOR BRACED WALL LINES SHEATHED � � THEN STUD MUST BE 1/3 OF SPAN 1/3 OF SPAN 1/3 OF SPAN � � J W WITH WOOD STRUCTURAL PANELS AND BOTH SIDES OF ALL EXISTING DAMAGED DISTANCE D: 24' FOR BRACED WALL ONES SHEATHED DOUBLED N NOTCHES OR HOL S FLOOR JOISTS WITH PIPE PENETRATIONS 0 W WITH WOOD STRUCTURAL PANELS l� 114 DEPTH PERMITTED 1/3 DEPTH „ 32" FOR BRACED WALL LINES SHEATHED OF JOIST OF JOIST GREATER THAN 2 DIA. I"— I"— W m WITH STRUCTURAL FIBERBOARD. BORED HOLE NOT TO BE U) W _ LO DEVICE-HOLD- F°ASTENETO THE EDGE THE BRACED �I� GREATER THAN 40% OF O 114DEPTH -1" ?" 1" N N L�- M WALL PANEL CLOSET TO THE CORNER AND — - - -- - - - ----- --- OF JOIST STEEL ANGLES TO BE: 1 2 X 1 2 X 4 TO THE FOUNDATION OR FLOOR FRAMING THE STUD (MIN) AND 2' LONG (MIN) CENTERED AT 0 0 0 I— Q HOLD-DOWN DEVICE- FIRST BRACED WALL PANEL BELOW 3„ 1/6 DEPTH ALL PIPE P EN ERATI O N HOLES (TYP) W W W IN CONDITION 5 N 4 MIN OF JOIST PROVIDE A MINIMUM TWEEN ' USE #10 WOOD SCREWS 3" oc (TYP) O O O SEPERATION BETWEEN n 0n n HOLES AND NOTCHES NOTCHED ARE NOT PERMITTED 1..L - 1..✓1... W END CONDITIONS FOR BRACED WALL LINES FROM MEMBERS FROM EACH OTHER AND IN THE SAME LOCATION AS HOLES EENDS OF 000 OO MINIMUM OF 2" SEPERATION BETWEEN 0 EMBER WITH CONTINUOUS SHEATHING HOLES AND NOTCHES FROM EACH OTHER REINFORCED DAMAGED FLOOR JOISTS � AND FROM THE ENDS OF MEMBERS FLOOR JOISTS) ❑WIND ANALYSIS - WIND ANALYSIS HAGS BEEN PERFORMED IN ACCORDANCE WITH SECT. R301.2.1.1 METHOD '3' (ASCE 7-16 ' MINIIMUM DESIGN LOADS FOR EXTERIOR AND BEARING WALL STUD(S) ate: 02 02 26 BUILDING AND OTHIER STRUCTURES)..... [R322.2.] Scale: NOTED Drawn: BAJ Job: 3 B_RA CED WALL DETAIL: ALLOWABLE NOTCHING'SCALE. 1/4" _= 1' 4 SCALE: 3/4" = 1 ' sheet A 9 of — Sheets i Received OCT 21 2026 REVISION BY Zoning Board of Appeals 6" MIN. 12" RECOMMENDED 4" VENT THRU ROOF 4" VENT THRU ROOF I— ROOF I Q FROST CLOSURE NOTE RESIDENTIAL CODE OF N.Y.S. P3101.2: OC) WHERE THE 97.5-PERCENT VALUE FOR OUTSIDE W � 0000 3" 3" DESIGN TEMPERATURE IS 07 OR LESS, VENT W OJ } CO 00 EXTENSIONS THROUGH A ROOF OR 'WALL SHALL p Z W NEW BATH 1 BE NOT LESS THAN 3 INCHES IN DIAMETER. Q W = LO C ANY INCREASE IN THE SIZE SHALL BE MADE = J H A2 NOT LESS THAN 1 FOOT INSIDE THE THERMAL Q Q — U) , 2" ENVELOPE OF THE BUILDING. O J L W W Q 2" 1 1/2 M 3 0" 11/2" c.� FOUNDATION LINE We v LO ROOF EXTENSION NOTE RESIDENTIAL CODE OF N.Y.S. P3101.1: 2 2"X10" HDR. 2ND FL [—TUB—] OPEN VENT PIPES THAT EXTEND THROUGH A ROOF SHALL BE TERMINATED NOT LESS THAN 6 INCHES ABOVE THE ROOF OR 6 INCHES ABOVE THE ANTICIPATED SNOW G e a C.O. 2" 3" 1 1/2 ACCUMULATION, WHICHEVER IS GREATER. a , 3" 2" 4" _O 3' X 3' TAFCO 88000 30"x48" CASEMENT W ~ CLEAR OPENING NEW MASTER BATH " EX. KITCHEN " � '. , . U 2. 2 SHAPE PRODUCTS: " 4" 1 1 2" CY)zo 0 50 IN. W x 36 IN. D x 60 IN. H WHITE 2" 1 1/2 / °- STEEL EGRESS WINDOW WELL v WC ss DW z \ CX1 2" 3" FAI ABOVE SHAPEPRODUCTS: 3-STEP GALVANIZED STEEL BASEMENT WINDOW 1ST Ft sH. GRADE 2" 52 IN. X 38 IN. POLYCAARBONATE 50" WELL WELL EGRESS ESCAPE LADDER C.O. 2" 3" 2" c o 3" SQUARE EGRESS COVER WIDTH C.O. EX. BATH ##1 4 '' - �-x ~ tC. ?:, '00�\ 4" PVC ® 1/4"/PF. N1 VIEW EGRESS WINDOW ' 1 PLAN ; 36" PROJECTION REQ.. FOR EGRESS. TO BE INSTALLED AS PER R319.2 4" CELLAR TO EXISTING N S.C.D.H.S. APPROVED SANITARY SYSTEM }, M O +� O I'll- N L L " r- Q U) r 04 U � z C0 1 (13 !E _ LO j � � � i (0 � � r W S (.0 U CU ~ N N � 2 L- BUILDING LINE c � T-0" 1 DETAIL: PLUMBING RISER Q SHAPE PRODUCTS: SCALE. NTS (2) 2"X10" HDR. 52 IN. X 38 IN. POLYCARBONATE O SQUARE EGRESS COVER 2X6 ACQ PERIMETER y, MINIMUM PIPE INSULATION 1'-3" FINISHED GRADE LINE APPROX. 3" BELOW WELL Z a� -- SLOPE GRADE AWAY FROM WELL MIN j M TABLE 503.3.3.1 2X4 STUD PARTI1fION r —_-_ I— PIPING FLUID PIPE SIZES T— I—i I I--III 1=III---I I II- SYSTEMS TEMPERATURE �- --- w.c. —' TYPES RANGE, ?F. RUNOUTS 1" AND 1.25" TO 2.5" TO 5" TO 6" 8" AND o I I A I I !i! UP TO LESS 2" 4" LARGER W z I11111 SHAPE PRODUCTS: 2" �b> V® BASIN SHOWER z 50 IN. W x 36 IN. D x 60 IN. H WHITE HEATING SYSTEMS �, z , - MIN (' --- _ STEEL EGRESS WINDOW WELL HOT TER -I VAN z W < Q :1351 TAFCO 88000 30"X48"CASEMENT/OR EQUIL -- _ = 3-STEP GALVANIZED STEEL BASEMENT HIGH PRESSURE/ I_ TEMP. 306-450 1-1/2" 2-1/2" 2-1/2" 3" 3-1/2" 3-1/2" \ WINDOW WELL EGRESS ESCAPE LADDER MEDUIM PRESSURE/ 251-305 1-1/2" 2" 2—,/2" 2-1/2" 3" 3" Z f- -- II TEMP. > -- LOW PRESSURE/ 201-250 1" 1-1/2" 1-1/2" 2" 2" 2" m O z _ __-III GRAVEL BASE TEMP. _ Q LOW m COMPLY WITH R307.1 U W W - TEMPERATURE 106-200 1/2" 1" 1" 1-1/2* 1-1/2- 1-1/2- U) U) FOR MINIMUM FIXTURESTEAM J ' _ z -;<_> :, �_I I I CONDENSATE / 2" CLEARANCES LL _ I— (FOR ANY 1" 1" 1-1 2' 2" 2" W t�`„' :s GRAVEL FEED wATER> Q W — Q m u r- `t' _ `I COOLING SYSTEMS U W a � >- >-- 1 W ,'; � . CHILLED WATER, 40-55 1/2" 1/2" 3/4" -� I�1=� I� ,I�- iI- REFRIGERANT J I_li -_)) I_ I AND BRINE: BELOW 40 1" 1" 1-1/2" 1-1/2" 1-1/2" 1-1/2" t ° _I_'I-III-Ili-1 1 1-I O O 0- Q FOR Sk 1 INCH = 25.4 mm, 1 FOOT = 304.8 mm, C = [ .(F)-30]/1 8 W m FOR PIPING EXPOSED TO OUTDOOR AIR, INCREASE INSULATION THICKNESS BY 0.5 INCH ^ ^ (� -j-1 --I b. RUNOUTS NOT EXCEEDING 12 FEET IN LENGTH TO INDIVIDUAL TERMINAL UNITS. V) V J �+— LC) I I-1 -1I III- -I 1=1 -I �- LO III III=III-I11- III- MINIMUM PIPE INSULATION N N M li —i � I TABLE 504.5 0 2X4 STUD PARTITION III-11I-.1I I1 i1-1I1 _�, ,;III- Q I—III-11 x —� PIPE SIZES W W W SERVICE WATER NON—CIRCULATING CII2CVLATING MAINS AND RUNOUTS HEATING TEMPERATURES ?F RUNOUTS UP TO 1" UP TO 1.25" 1.50" TO 2" OVER 2" m 0— CL W 170-180 0.5" 1.0" 1.5" 2.0" 000 0 140-139 0.5" 0.5" 1.0" 1.5" LJ— O. cl+ WALL SECTION TROUGHIE WINDOW WELL 100-139 0.5" 0.5" 0.5" 1.0" �- 0- 0- °- 2 SCALE: NTS FOR Sk 1 INCH = 25.4 mm, C = [ ?F)-30]/1.8, Date: 02/02/26 1 BTU/H/INCH ft2 ?F = 0.144 WRm—K). a. NOMINAL IRON PIPE SIZE AND INSULATION THICKNESS. CONDUCTNfIY, k = .027 Scale: NOTED Drawn: BAJ Job: Sheet A10 of - Sheets i Received OCT 2 12026 REVISION BY Zoning Board of Appeals IC� r C 0 ti W > OMO Air staling key points n�'n'w'dr� Air sealing key points tm=awed Air sealing key points Air scaling key points LrrlUrlvNU Air sealing key points c+ondntied _z ° W F- u J Wall cross-section &sa!1gt+a.na Q � �' Ce h~t 9nt �w�"e s opt i-- J V. cai:rrlp dywtrl + Combustion chase Combustion closet t 2 Chases end common by-passes crp>naal�r>,ea"t Window rough opening !" Gaapa tC npuaa6�:•• A m ' th All,to 1 a r oa ,• Awe penetrations , LO We.na„era ttino.� '- CcrMt»^t,r "41 •s per N>, A,t+pa s oc" C,a ape to llt'+it wa.n Dawo srd da•n hr I ' can vra toe Sea a^ound (uncone<nrsc) r' I Sir-p'Tea de ina i s.`•W firoupn axlarb+ C!tr no-/toes Sm' - - -- -�_. -_._ ( \ 4. Willsoo'ee at I� wnnNra� 1;". 0110 . �I r— 1 t i Po,v:'aaon p r"etal'�n Fl.re eta:x r ^rr-,r^ r.' n nur ewts M+ 111Iff1��I1I1I1II{( ' - {I' SW !�_1 L `+AIY• '+ i ,i I 1 '.i ,� 't,,11a, /+t • �-�t:�1, .la^+n'o••a*ura• -�f '� J- c-`3 .r'•�' �I 1 r _ a -S1 nf•.FRV7 wN It I { t / - - - 7�. -'f .:.t_ - - - -- __ ' Ssal r v±S lots ___� Santa ,r ICta'a4 w*AAl'e sh,tr bll a Irn3�Mte i,t lnam ga.c.T / i 1 /'. S•IrR vIW t acoaaad t sheet ma�ral m arti x,mena x>rtr M Intema'A"Dt^nnl . ! San' a and -- - , tisnrtssrodryw•al MntrdDamty4 I� pvrtvy� �\•°L°�\?� i all W ee.erakeMrtertm-.r.,Ile tr�io-i-l€•n-8dIW:Yt trvsMsf 1 Y ± Ir,a g•.YAlle ceJal _,, ❑�! Sae' Iratlst:adarto^gar ry•-k. 1 - +„ --,.'.. '��-,1 V a e'M t•kal MsRn r � Sea MV6„ G'uc QrylAy,.M �/ t:�` { yy � i � +C �? ,�s•�_ / . end atrurot tt - � pa-•st+s«a�e ,,Y' , •sl �_+.._.__�---.- � t'RComr-pyr.d o'J'ww.7 wlw• tom. t ,_/ drynall 1 pen.¢Tarans f ' (1+rr^d'ienrMrS o'a� tr area g s rs 1•rys. ! 5 I like- ,py'}' i {r-- r�f.�r tra^+a'.M rt L MSI }, It �:.� = -•""'' � _ r Z I awelr+s^l y N? `} �A•4x :� I � ' ( Aasert+mt rr� .,.,r_- .. z00 Ca <Datrorr >:w .0 ,t r I i r n ..�•- � �; � i ecnaa,•yed �" 10 autN Sella ectnca, f` / I _ ii I ,,.--�-1 iI^. ( `".,�,�.—.�,- ° �,.A ! a•p - �t.�" atcvt � ," � int arsd � prnatratcrs ..� :- -' , ' j � ++ss _'r n sti Mr - lI- / ti�+ t>s' . rod t a 1 t (I 4� C 11 i "�` �"`••, i G3ntt8v4'rQ M1bar 1�"'ti J V \ •r...i_ +A't�'tr trwY'\w{.e•«r S�panMrat one I^xmr•wn wsl D**♦ a nr,r t i-; rei F i �t..r.e i `� �`� c i . ; 1 PaR d tA,W:^g o v,-• MsR !n•en4plrtas i ! \ c tf (msQu1w1} � • DCnom �_-._— �J r f i •` \`� !.�,,J _ _ 1 `P6{ r 1 �Ga Soot pf Me`_ ( M .. • _ _ jj j�/K�11'�� I `- - 4 �!��` Nttr•Gvr stud '1 I k jp'h j(,I/ 'x} ` t i U"(ill MA M W00Y kWM C ROW goii r'J�rs�"ft� i I � `� erg tty to!It lna i� ` tw, a It 1! t Inf::�MeQ (eoomprate 1cr w,ndeyrs)to rFr paps d� „ wa neerr, CN N:A,^atklt 'i !'ittwe9•T WroCW,aacr art:rough n , t� I aulY 4'x:re IT (1F:da'ttrar rsWatlnn A=JY be I I I �.1.�-. ° (net tv7u rt♦al t^ae•pA•aa•"-O ntvSB do[r _ O:ua dr alto t-a late �/• ! C Ir hs a e t pa+*wrrorl�r NC1 tr•r r nry. o^rtnr p Yw n k atancr I F `fl3f; \% da's o will M r •r ++k. i troCM'cnRfR}vft TaOo WCA\1f e � , au, oa 4e t+e arnlr r,st\e-e i 'F, sult9crOnt rea\rred al sry On--"se enge -- {Irr7 rn xuH i r t- j 1 L7 • CaJ1K - k^_D fifal - :i .�. I. f I I II+' •tlI:'>.: " t �C'if . t ,�� I Otro+coseaA' �'.i' d�'1i [�Smtat an7 soot•r b-M,0.4'.,a I-& s �7 ! ' I- I ads,^tr epld cW0,11hXa Bortcrr.p+e•e Showerltt.lb drain rough �i',J Ire o-� I (� I tralw q G'ue drywsl fa frnrrrrl pia+e opening (n+cor'rForxSe9t C`aurstmttrnFists "�-�► {rl IJ�, Exterior penetrations A6rsessl �, }C ?� 1nvor erw-W 1 1 Co J$e.ts'tar wax po•etm%0—e►_r »'�'nc��c1N+Mi dao•wa\nsN^a Tar17-- n F)( l/ wa:e r0.vstiva - t Mr+fgrve•rut xt:ey.rJ^tY_mote x e.!W' J �` �r '' '" t j ' Sdgr�♦r+nrd•1d•I.+G.:wIIIc.nttlltur�n'tTrv'nt+�n!r if3Cr3?2 1-.L:-i' �.�i I ,.• Eror:orvro\Cktsstaiat �� � �',✓y Soh*ire •�i�.� =t.�`°` ti31 II / U+.�U�l' " � 1. r tOnO•(rJn•nOaLrt:o' Yaax 9-n�+4wrapa�ctl''r+pMs i M ins'!-*t n*,ea.+enCr tJ1 -w�+- •..•.—' "ng hA1+�irod IMx a eel•-M+11rM7 t: ' tint A •ri---- !r Seat w tM Y term ort bN r s,p rn,u rsdl + ,._- /�// •}, i !`�irtl:i4ibNf b U"M�ocr MwMKc+n yurtWp Pe^d•ena+♦ tzar sfw't»rt"+rleJ � � j{ (rcco r++enlaoswr•np wrp' attached nua:be etat3l'eQn sd to w'1!a portnanarY CEn•4C1 wit+ -•� L suMaor Sa•T Mf'i+St .� "� (CMdt"�r +�•i } O ScaaM CLASS I re:Lt+e•:at air e.�aaea r rapes re'a•l1e• v'po of InsvNnOr•l5s•r,•r•..a o•s, w r d r^7 v fired In aaw'spsas Y U 11 L C5 CO C-4 AIR SEALING BEHIND SHOWER WITH THIN- Q T AIR 5EALING AT DOUBLE WALL5 PROFILE SHEATHING U) z ~ LO iY?llUt aLxltlW_Al C SI UU:.Afil•'4 SI!]MtN AI t1lIF OH MALL > G 0 1 L ICU 'JNIINUa U$tlt AU aY ♦/ ( O �� 76 INSJ-:TED IMEPoDR StnL9NI i STJUA. cy) CO R1Y<M}ASRG21wEU J W � � v/� LOIiTIN..r)J56E:U OF$FJ.JdrT VJ co co I It SUNr!'J1111U MNISX ♦y J""LN'aRtHH�HV Air sealing key points ��:�t�d Air sealing key punts �rt1=,K,«f Roofline installed Insulation Options Ceiling Insulation Details Q `o = Q) NsuLAl to rxltHHxl Kota W,nd wean bathe she u- ermeable Insulation oe�m F_,I e�•utl^rat♦n r SI UU MALL I enN-I'X(xat e!..0 L NST.A_NTEWIOR$XEATHM9 SXtAI HIN'.: In1.,a•lfr-.'„Ktea t^IL! :a \YY'Ca.-rNu e•:Id•etK°'rC e!Y4•a^,e eE+e f�df'Pr Ar,tl 1'ru45 w_,s,t nx•}xrr+^t c'a t..,J t,r I(M:-9 s'all ea yc:aid h7-wWf"+•,a t-rr aaan FROM TO INST.�4rION tIF ((�q F}�(flNISH Er�lJSJPE a,•- t-IUri tt�p.�•r',S'a^.7•era•ba^-a't] and!-*,W{•aaMYi�a'M N•+'.f t7'!aFJ1 of r•kr fd�! tf a tNat'la t•dl a•ef (p{ * F°, w ww'v w�d-+'atr.rtaL nr,late7 on•r a ic:G O'7 a a ar,ta•vr r,w�o.Ir•, .t r a• eea,s 4,cr"6 *,?clot r N�r..v rr,e :ANTINJOJS 8E-0•JF ^a \,�, `� Attic t t� $EzAni Hrv-:�,�',. d '~ •O;l'i•elh:.s'Y?� M411 ri $r.'V�lifl AM fmpermeabfe tx+c+7•eesrFa!r•. ,Sr;.x.�d•'t.wN t,Fr aN r,9r v,e'd C•t•Ie,r.a to R _ (or 0M insulation ,,__ _�. pFownr:lc'asa�1 (e?. '�Y teem Ina;,era+) Snt,pw-s w�lh tap6'E1� s!sen ng s^.a t N petm•sam+e is Y.t t»"a 5tandardTruts `. F.fX]R•SSEIXC_Y rxlbwumc I 1 .tom ,, ���,.} •', $.a'va snr.vae a,parr ,: Hatch lb tAt5hC5 UP anC ---r�tYJu rNawt '�! Imo. t"EtiAYM k,r'1 GR?t 79 My be 4:11r4! �'••'•'^" _ I 1r�5•,;'t1'NJr'1 Q9t.`tlt _ �'iti`A -•. FIsx;X.4ssL t• .` 0.13 ria,la•eo t'+ea:f.-.g al[ i P•18 ir.soWT-or ---1r `", s1{tt:a �L f1j a'e:A'e^'s^F� '`�^,�... � { +_�<, .'—."^�""�-,..�f• i p (/A ��, i'\t�tN•.n t>et'1a \`�, P,0r3 inau+9S'•n k'�E C.',t't 'rMrNJb9,. -` f k•NaJa - f ! O Gv,%,t p�uNa e*narti /1 1 NA 1 t txatg •�,5 f `�r��� �\ /� R /� 5 it i Jt l ), r, �1. � 7 "� aabtaa•glti AIR 5EALING,AT RECE55ED LIGHTING IN ATTIC t _ f i� ONtivrq .,w,.w '}{i1 M AIR SEALING AT t '� ` , CORNER VERTICAL P "o i� _ �r f/ Enw9yTruas l� CHASE / - A.r Wt ,: mstehle re\aa-+c- 7 ^--' jtt` HiNJFA.'.TJREU RFi ES`_ED�rrr EH.'-lJSJRE / -.r-�.` Au"Mnadb;*t\aulat!on y Qh tutj he r,,nidatio� :.Tfl`IrrSJ_TOr1 „f (a. ,cow,O':!,7wl- R11tXIJH`ItXll"' AT7ICTR 5 r _� Trm p -e R•1@mlr w / f'~� !- f pas><9t ce,Sorely 108m) `\' ' f �_ Inv:tllon Da • lw-7nut INI tNY,xe SXte HI (I mu'r1 R fildv0�!aA tRt"C 1 .MlPAMINI/M.ALL11tl• .,,, - (reCOR'zn9't79C. �``� — - -- F• IJ lnl tnaN'rwL cr nL /'�'�r} ,,,/�-`` .. 1, }• (GoCayta rQ�t1,QRTUrSi} �. mil. .-'-r. ' J z `" Attic pull-down stairs . 7 ` -' W p "'.� r SI` � ;;1, w/ z ,Mt Y- •,�-'J�- / /'/ �f , Air-permeable SM los Al'1 ^•tYeti+:h5l>'i'�:rt 1, �1 , + (/jt' Jd �'} r.r°w. IL�i1r'�1� O r �,� 4— (a G.rigid Item Merl 1 t ) "�' E%P.�lans Fow'.E�AWi Ar rEwneTER '''� �.�- P,- d InfWetlrw,iY,r MrmS W tCr Of+-4owR Bt!'r•at3'rCa4e Qrrryy pn_"L"'+:.tO i'17r � m�0 ti ,1 k (ry�pr•\TtardK) tngtalledlnaulatiOn ;• . . a._,.,_: 1 _ u•2w'aw ,qn n/ :AMnJOJ56EaUOF SEi_Vtf ,/ / ./' a ftal"CSS�t RAa ftj�tt h l'1(etld 1....�` _ R 5 m n:°rn^Ir c3'rara rows 2 3 9 �,•iv !.'+a att,lY9t♦rh+soi 1' Old w+trt trs,�la•*X•on 107 �/ ? "� �J}-�-. , { J ,r } ) F. I+ELFSSEO-1_-HfIN1 FKTJRE f � / /•� - `�^^.R -V.,y,- •`•^-Jr j•�� R'15 R1irY•+4F�/1 C�ITytO 2t7rrt'li /11 !°. f', J�' .\ W LAUUn1l rSLY'KIN'.•.AS XLVUXtU /•' •. , tr♦ar�ia;hn drarRb pftirent I;o�r t1aA PJaneS UO INSULAI EU t%I t:HYJIt MALL -t. 5 � aaae-^t'lrtsi3tirF�n F'0r•I � pN dV'd t!^a srry ICr } ta►F S it-o ran access s xoss N. Watlon tact - !f - St IV•"' mm«arnR-5 OptIon1 Roaf:^pt>Y cer.od7,'oa,rrd �t �1l'` t/ti 1/` 1` tt7ao+garwqura^snn 1 (Crrr,,orapuron+ertl �w / r 7 o /( '�` / Standard rafter t L p (n A!rwwrrreetYernsuta�tr:+t ' and top late / le.p ph L _ .� O Q with lapel®d W I Wwa:krrst•eitt; II) r,-- y�f J� \: !f tnsl]'A•On dPptl +);�*e+" Attic knee-welts Two-'suet attic ,I waatnerGtrlpO'nr . �_ ., ! trams YY t` 1 ..,rF., n r ��/'�t An" �t - •.} L`-_..,�' IN'rJci'N� '�--- �"--- :( / t_�_�1 i .j...} .'•-���� ^5 f at A r°permaab•e trsutaticrt A {+enrnert et r aNa. rt , Q • 'r ` _ tl 1 1'Mi w P 1 g rrr:mtr+ t<tv�!tiwsa e r+•xi I { t' `� ( , t 0 tr•..• \...•a...e+ryt,r..y' '� .met foot 9�►arwnon a'aTa i ^�"`..-'-...:..' �� l4 +` --- - k t i t v Q v �/ i.a I ,,�+, t'r !, fGa+xOta nnu'mmorcst � � �i � t .t !,l`7 J�� � +r[•�sna'd.r •t G/1 W 1 -+.•� or y rolrr ODeftirtp wM t --- ---- --- \ M gNJk M:3Mva,atfrom ---�.,. ` '•` '•.(Lama,e•r� W W 'I � - •�---�/I��Ceu•era sues �' C a..,• � ,-,^_'7 4 v QI Ij `� Attic pull-down stairs o ' "" ^y.v}rr,rrw.dege { !-P+e wNnr ` Rafter on falsed lop plate ]p� O O '� 1 Q jll r s tJ'rp t•!'°MelA+trTv'r++o a-.'i wlln Suh I- Mf I 110r, !'' � r . tune -it-0 —Pravtat dada O BBnt I _ kt-r L �M\ PYJ'M-ra haoaz.r tf�"I Sea •M`.Canr,.y, option 2 (recorrmF Oedi 1.3 e _ (� W yam' Car,'s rough oper+nq a '.y '-- .i: fc,rwNat.;n� In 'v^J i hc.+r?r\m ly-Somali rod a lark^^ a. " jf/ __ R_ a ten, ! ,� wa.oam j ' Yicat•oo stryp'^7 • ; ' _ ..-�.`�� o N L V U M 0 0 s+ercr' tMost»e.srnaQvc eta x"c. �tr` ~ _ r>7 f a gl rin�dkartDrJava[n {.arJ,..,]wr°ctv!. rxta•^RY,�snrt t•' l -� -t.t-- PeQ•t r, t //' � "��"�«.. P.•5 M�InRJ'n In cf riM9 mrtea?d 3 ?-. _ � ! ..-: "'t ta,sea top Ola a Q +J•r tr,,r a•5 t'+as^cv] / /%' P•15 r•9n>t.surn.r Cfntth 7orly as 4 - W W W Ad 1(;gry y•'rlWn+•I whit alit as.w Irsuwt.c'+ f' � �,'�,,�'� �'4`.1tt �/� �/� �/) Ins:M. . isttr at to g n W e,am boats• --- t �I f ,4' ! �+/ v 'Irm t'a1rM mtntrtum a-5 A:ngar+r6e♦DW t•aula9cn �i�.`�"F•--.- 'r --=-_- --__- -- ---- - �/ Ir�gryrrfa rr ,oratrartt) r;; t'l ,,' -'�`. / A<'r�+ssrrwgflte t^rJatun �_ 0 0 0 L1� R-19 rraN-url n tralo-tr•s e' F '°"r W arms twod(t3eargta � tYOt.IrTTter':ta) 000 O CL , 1 0— Date: 02/02/26 Scale: NOTED Drawn: BAJ Job: Sheet A 1 �1 of - Sheets i Received eCT 2026 REVISION BY Zoning Board Of App is ROOF RAFTER HURRICANE CLIP (SIMPSON STRONG TIE—H-15 OR EQUAL) INSTALL TYP. AT EVERY OTHER RAFTER FLOOR OR CEILING JOIST Q"COR—A—VENT" V-300 RIDGE VENT OR EQUAL o� SHINGLE RIDGE CAP �° _ � CO DOUBLE TOP PLATE Oti -= EXHAUST WOOD POST (SEE PLANS FOR SIZE AND \`, W O w SHINGLES C; LOCATION) J Z m ch ROOF SHEATHING TRIPLE STUD O _W Z C BASE (SIMPSON STRONG (18) 16d _ = J F— COLUMN FELT PAPER RAFTER TIE—CCQ SERIES OR EQUAL) SIZE NAILS Q Q J U ACCORDING TO POST SIZE (2) 16d COMMON �. 0 WLO RIDGE BOARD •. � P NAILS ® 6" o.c. 3" MINIMUM FOR FULL HEIGHT co OF STUD LO SIDECOVER ;\ FASTEN TO POST AND BEAM WITH 2 U p MANUFACTURER PROVIDED SDS 1/4 x 2 ° MIN. LO ! 1/2" WOOD SCREWS, TYP. ° ° END DIST. ° o STUD •• 4 HURRICANE CLIP DETAIL 1 TYPICAL RIDGE VENT DETAIL — •• NOT TO SCALE ' S NOT TO SCALE SIMP'SON "HT 16' t, WOOD BEAM (SEE PLANS FOR SIZE AND i w, LOCATION) •ti ® COLUMN CAP (SIMPSON STRONG TIE—CCQ ° \ SERIES OR EQUAL) SIZE ACCORDING TO POST AND BEAM SIZES — ROOF RAFTER i o HURRICANE CLIP (SIMPSON STRONG \ cIlk TIE—H-5 OR EQUAL INSTALL TYP. AT TH U—BOLT ) \ \ EVERY RAFTER WHERE STUD IS OFFSET . C. 4 2'-0" ICE SHIELD WOOD POST (SEE PLANS FOR SIZE AND LOCATION) SNOW & ICE SHIELD FROM \ \ HURRICANE CLIP (SIMPSON STRONG EVES EDGE TO POINT A, �° TIE—H-6 OR EQUAL) INSTALL TYP. AT \ ... MIN. OF 24" PAST THE ° FASTEN TO POST AND BEAM WITH SIMPSON "HTT16" 0 0 0 EVERY STUD WHERE ROOF RAFTER IS WARM SIDE OF WALL LINES o MANUFACTURER PROVIDED SDS 1/4 x 2 \ \ 0 OFFSET 1 2" WOOD SCREWS, TYP. 1r / \ I DOUBLE TOP PLATE r'a.` `3_`' r Z( s ' fid�t4" . `� STUD - -- - ROOFING TYPICAL WOOD POST EASE \ 3 2,n d FLOOR SHEAR HOLDD OWN \i a FELT PAPER 2 AND CAP PLATE DETAILS - °°` �, CO \ NOT' TO SCALE o .+.. ,d T ROOF SHEATHING NOT TO SCALE � 0 T/ON Q \� INSULATION cy�TF N Z U LO HURRICANE CLIP DETAIL > � ti 5 P OFFSET STUD / RAFTER ° — _ (Dw E' � U� \\ - DRIP EDGE NOT TO SCALE PROVIDE MIN. 12" U) �- Cu BEARING ON STUD FACE, Co LO CD N L _ N R (TYP.)\\ L_ _0 "a B C OARD Q USE EVERY OTHER NAIL HOLE IN DSP SILL PLATE TIE (WALL SOFFIT A ROW TO PROVIDE THE (6 11/16"x 2 3/4", CODE-REQUIRED MINIMUM 001 TYP. AT EACH STUD VENT" CENTER-TO-CENTER SPACING "OFFIT a FOR NAILS S-400 SOFFIT r ` VENT OR EQUAL Q I 00 I _,CD (_6 TYPICAL SOFFIT VENT DETAIL o •-� •I WRAPPED UNDER � '. •° SILL PLATE �J NOT TO SCALE (TYP.) ° �° o y W Z NOTE: HOLD DOWN ANCHORS SHALL BE � 00 z INSTALLED AS NOTED ON THE FLOOR PLANS. o O WHERE HOLD DOWN ANCHORS ARE INSTALLED AT THE FOUNDATION, SUBSEQUENT HOLD DOWN W of ANCHORS SHALL BE INSTALLED IN THE SAME HEADER SEE PLAN FOR DBL. SILL PLATE-FLOOR—STUD CONNECTION Q LOCATION FOR EACH FLOOR ABOVE. FRAMED WINDOW EXACT SIZE 1 O DETAIL: SIMPSON DSP STUD PLATE TIE HDU5-SDS2.5 (OR EXTERIOR z 14 GA. 3" (W) X 11 9/16 (H) 2 7/8" (B) - TYP. STUD - ;G ' (BOTTOM) SIMPSON RFB#5x16 EMBEDDED 12" W/ DOOR) NOT TO SCALE _O L O Q SET EPDXY. CNW 5/8" DIA. COUPLER NUT W/ f W ° A-36 THREADED ROD, MINIMUM 14-SDS 1/4" x3" SIMPSON STRONG-TIE USE EVERY OTHER NAIL HOLE IN A ROW TO — U USE EVERY OTHER NAIL HOLE IN A ROW TO PROVIDE THE � !�''� WOOD SCREWS (TOP) SIMPSON PHD5-SDS3 W/ CS20 AT EACH END OF PROVIDE THE CODE-REQUIRED MINIMUM ..I L.LI � CODE-REQUIRED MINIMUM I 5/8" NYLON LOCKING NUT ALL EXTERIOR WALL CENTER-TO-CENTER SPACING FOR NAILS Q 0 CENTER-TO-CENTER SPACING A - HEADERS RIDGE Q FOR NAILS m U \, CS20 STRAP 20 GA. �\ \ ° . 00 �/ J W dO 24" L., USE 8-8d TYP. RAFTER I� ® � NO SPECIAL UPLIFT NAILS AT EACH RAFTER �\ \ �\ O O W Q CONNECTORS / m REQUIRED, THIS (TOTAL OF 16-8d ;� ®I AREA NAILS) )� U) (f) LO LO I e /" (, LLco Cd LTP4 20 GA. 3"x4 1/4" o W W W % LATERAL TIE PLATES \' USE 12-8dx 1 1/2" NAILS (6 NAILS INTO PLATE, 6 NAILS INTO 000 BOX) %i \\\SIMPSON STRONG-TIE DETAIL AT FOUNDATION NN NN �Ny O � � � L.L. L.(_ L.L CS COILED STRAP AND EXTERIOR HEADER TJI RAFTER SHOWN (SIMILAR FOR DIMENSIONAL LUMBER) a, 0- a- a LTP4 LATERAL TIE PLATE PREDEFLECTED HOLDOWN 9 TIE DETAIL (SIMPSON CS20) ( � - RAFTER —RIDGE � RAFTER Date: 02/02/26 (_�711URRICANE STRAP DETAIL ('8__� ANCHOR DETAILS SIMPSON PHD NOT TO SCALE _ NOT TO SCALE ('11 � TIE DETAIL (SIMPSON CS20) Scale: NOTED NOT TO SCALE NOT TO SCALE Drawn: BAJ Job: Sheet Al2 of - Sheets i Re ce1veri 202 REVISION BY Zoning Board of Ap eal 2x P.T. DECK JOISTS SEE PLAN FOR SIZE AND DIRECTION H1 HOLDOWN INSTALL USING 6-8D 1-21" NAILS 'TO BCS2-2/4 POST CAP INSTALL USING 2X P.T. LEDGER BOARD JOISTS AND NAILS NAILS TO GIRDER AND 6-tOD � � " ` NAILS TO POST L.._. SEE PLAN FOR SIZE 3-#10 NAILS TO GIRDER , ' j t.J °q CC a o 2X P.T. GIRDER m m G O t` \! ST / 2x P.T. GIRDER " a :120 SEE PLAN FOR SIZEINSAWS2BLL UOSI NG 10DGER 4 \ Wco SEE PLAN FOR SIZE o ® m � � MCOMMON NAILS o a ! ;jj � oo _jzC° M Ui' 2X P.T. DECK JOISTS Q ' `` % I m -�' ;i Q Q co �' ' SEE PLAN FOR SIZE i \ i` ! I lI �'r' I'iii 4X4 DECK POST O Lf) - `\� m Q I \ _ i I - ® BC4 eCao m Simpson Strong-Tie SimpsonStrrong-Tie H1 ® � •� 4 LUS28 1 TYPICAL JOIST HANGER DETAIL (2X) z TYPICAL SEISMIC & HURRICANE ANCHOR (2X) 3 TYPICAL POST CLIP 4 TYPICAL HALF POST BASE NOT TO SCALE NOT TO SCALE NOT TO SCALE — NOT TO SCALE L fry 1 6X6 DECK POST MODELS USE (12) 0.162 X _ MODELS USE (12) 0.162" X \ /\\' :% `<�.. ,: 3 1 2" NAILS ONLY. A 2,. 1 2" NAILS ONLY. \, \ '' , - 3 / LS 0 Y. A 2" \ \ MINIMUM SIDECOVER IS `1,_ v= ABA66Z POST REQUIRED TO OBTAIN THE REQUIRED TO OBTAIN THE �\ BASE W/ 1" STANDOFF INSTALL USING FULL LOAD. MINIMUM SIDECOVER IS 8 10D NAILS FULL LOAD. ° 0 ° CONCRETE SONOTUBE MIN. 36" BELOW I 0 L GRADE ® l i® �a °II ° 0 ° 0 ) 0 ° o n o ° ° V ® . lr ° �.I� roll ° u^ ° (� i!�..�' ° ° ° ° +� O ,�, � m INTO P.C. SONOTUBE MIN 12" AND i c- THREADED ROD EMBEDDED I ® � p I ` I i a ,� � � N BOLTED TO POST BASE e yl I �, ° 5 ° Q c �- cNo ID o Se 0 �( O � O ~ Cu cu Co _0) V d I I a a e u n d J J d /0) W /�[[ de < n c a n a s d d d O / (0 Cn d O ed a d V '^ ' ev e ° d e a 4 d � \ID/�a e �, d c a � c Li Q ae O Q Simpson Strong-Tie d ABA44 Simpson Strong-Tie ' PB46 Simpson Strong-Tie Simpson Strong-Tie PB66 PBS44AZ 0 z co ('5_ TYPICAL ECONOMY ADJUSTABLE POST BASE s TYPICAL STANDOFF POST BASE 7 TYPICAL STANDOFF POST BASE s TYPICAL STANDOFF POST BASE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE U) W z 0 V W Q z � O O Q I— U w � _j d MIN. 2X8 DECK TWO GALV. 0 a 0 ® JOIST LAGS OR LAGS MM ® OR LEDGERLOKS < a11 MIN. 2X8 w ® DECK JOIST o 0 00 ® ® 2X FULL-DEPTH co O 2X FULL-DEPTH BLOCKING rr BLOCKING � 7 N N U- c� 0 0 0 W W W Q AU) ( MIN. 2X8 TWO " GALV. 000 END JOIST TWO GALV. BOLTS LAGS OR LAGS TVWO GALV. BOLTS ^ ^ OR LEDGERLOKS a- 0- 12- W 000 0— TWO 4" GALV. MIN. 2X8 fy 0� 0� 0 LAGS OR LAGS END JOIST ^ 0 OR LEDGERLOKS LL L 0- A35 Date: 02/02/26 Scale: NOTED r 9 TYPICAL FRAMING ANCHOR to DECK GUARD POST DETAILS Drawn: BAJ ° NOT TO SCALE NOT TO SCALE alOu: Sheet A 1 06--3" of - Sheets f i � r�� s ReCe1Ved T 21 2026 REVISION BY . PROJECT LOCATION: BAYPORT, N.Y. ATTIC FLOOR ABOVE CONDITIONED SPACE DOES NOT COMPLY WITH TABLE R402.1.3. NOT EXCEED 0..5 AND THE SNKYLIGHT U-FFACTOR SHALL NOT EXCEED 0.70. NEW FENESTRATION SEPARATING A SUNROOM OR HEATED GARAGE WITH 1. THE SUPPLY AND RETURN DUCTWORK SHALL BE INSULATED WITH NOT LESS THAN R-8 INSULATION. Zoning guard oT Ap e SUFFDLK COUNTY, NY 2. ROOF REPLACEMENTS OR A ROOF ALTERATION THAT INCLUDES REMOVING AND REPLACING THE ROOF COVERING WHERE THE ROOF ASSEMBLY THERMAL ISOLA ON ROM CO DTIO ED S ACE SHALL COM LY WITH THE BUILDING THERMAL ENVELOPE REQUIREMENTS OF THIS CODE. A is CLIMATE ZONE 4 INCLUDES INSULATION ENTIRELY ABOVE THE ROOF DECK. R402.5 AIR LEAKAGE. THIE BUILDING THERMAL ENVELOPE SHALL BE CONSTRUCTED TO LIMIT AIR LEAKAGE IN ACCORDANCE WITH THE REQUIREMENTS OF 2. AT ALL POINTS ALONG THE DUCTWORK, THE SUM OF THE CEILING INSULATION R-VALUE AGAINST AND ABOVE THE TOP H THE DUCTWORK, AND AGAINST AND BELOW THE BOTTOM OF THE DUCTWORK, SHALL BE NOT LESS THAN R-19, EXCLUDING THE R-VALUE OF THE DUCT INSULATION. THIS BUILDING IS IRES DENTAL AS DEFINED IN THE 2025 NEW YOORK STATE ENERGY CONSERVATION CONSTRUCTION CODE. 3. CONVERSION OF AN UNCONDITIONED ATTIC SPACE INTO CONDITIONED SPACE. SECTIONS R402.5.1 THROUGH R402.5.4. R403.3.5.1 EFFECTIVE R-VALUE OF DEEPLY BURIED DUCTS. WHERE COMPLYING USING SECTION R405, SECTIONS OF DUCTWORK THAT ARE INSTALLED IN [NY] R503.1.1.3 ABOVE-GRADE WALL ALTERATIONS. ABOVE-GRADE WALL ALTERATIONS SHALL COMPLY WITH THE FOLLOWING AS APPLICABLE: R402.5.1 BUILDING THERIMAL ENVELOPE. THE BUILDING THERMAL ENVELOPE SHALL COMPLY WITH SECTIONS R402.5.1.1 THROUGH R402.5.1.3. THE ACCORDANCE WITH SECTION R403.3.5 SURROUNDED WITH BLOWN-IN ATTIC INSULATION HAVING AN R-VALUE OF R-30 OR GREATER AND LOCATED SUCH SEALING METHODS BETWEEN DISSIMILAR MATERIALS SHALL ALLOW FOR DIFFERENTIAL EXPANSION AND CONTRACTION. STATEMENT OF COMPLIANCE: THE PROPOSED BUILDING DESIIGN REPRESENTED IN THESE CONSTRUCTION DOCUMENTS IS CONSISTENT WITH THE 1. WHERE WALL CAVITIES ARE EXPOSED, THE EXPOSED CAVITIES SHALL BE INSULATED TO FULL DEPTH WITH NEW OR EXISTING INSULATION THAT THAT THE TOP OF THE DUCTWORK IS NOT LESS THAN 3.5 INCHES (89 MM) BELOW THE TOP OF THE INSULATION SHALL BE CONSIDERED AS HAVING AN BUILDING PLANS, SPECIFICATIONS AND OTHER CALCULATIONS SUBMITTED WITH THE PERMIT APPLICATION. TO THE BEST OF MY KNOWLEDGE, BELIEF AND COMPLIES WITH SECTION R303.1.4 AND HAVING A MINIMUM NOMINAL VALUE OF R-3 PER INCH. NEW CAVITIES CREATED SHALL BE INSULATED IN [NY] R402.5.1.1 INSTALILATION. THE COMPONENTS OF THE BUILDING THERMAL ENVELOPE AS INDICATED IN TABLE R402.5.1.1 SHALL BE EFFECTIVE DUCT INSULATION R-VALUE OF R-25. PROFESSIONAL JUDGEMENT, THE PROPCSED BUILDING HAS BEEN DESIGNED TO MEET THE REQUIREMENTS OF THE 2025 NEW YORK STATE ENERGY CODE ACCORDANCE WITH SECTION R402.1. AN INTERIOR VAPOR RETARDER OR SHALL BE PROVIDED WHERE REQUIRED IN ACCORDANCE WITH SECTION INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND THE CRITERIA INDICATED IN TABLE R402.5.1.1, AS APPLICABLE TO THE R403.3.6 SEALING. DUCTWORK, AIR-HANDLING UNITS AND FILTER BOXES SHALL BE SEALED. JOINTS AND SEAMS SHALL COMPLY WITH THE MECHANICAL AND COMPLIANCE HAS BEEN DEMONSTRATED BY USING THE PRESCRIPTIVE METHOD. R702.7 OF THE RESIDENTIAL CODE OF NEW YORK STATE OR SECTION 1404.3 OF THE BUILDING CODE OF NEW YORK STATE, AS APPLICABLE. METHOD OF CONSTRUCTION. WHERE REQUIRED BY THE BUILDING OFFICIAL, AN APPROVED THIRD PARTY SHALL INSPECT ALL COMPONENTS AND VERIFY CODE OF NEW YORK STATE OR THE RESIDENTIAL CODE OF NEW YORK STATE, OR THE NEW YORK CITY CONSTRUCTION CODE, AS APPLICABLE. 2. WHERE EXTERIOR WALL COVERINGS AND FENESTRATION ARE ADDED OR REPLACED FOR THE FULL EXTENT OF ANY EXTERIOR FACADE OF ONE OR COMPLIANCE. THE INSPECTION SHALL INCLUDE AN OPEN WALL VISUAL INSPECT10N OF ALL COMPONENTS INCLUDED IN TABLE R402.5.1.1 AND SHALL BE R403.3.6.1 SEALED AIR-HANDLING UNIT. AIR-HANDLING UNITS SHALL HAVE A MANUFACTURER'S DESIGNATION FOR AN AIR LEAKAGE OF NOT GREATER R302.1 INTERIOR DESIGN CONDITIONS. MORE ELEVATIONS OF THE BUILDING, CONTINUOUS INSULATION SHALL BE PROVIDED WHERE REQUIRED IN ACCORDANCE WITH SECTION R402.1. INSTALLED SO THAT THE INSULATION MATERIAL UNIFORMLY FILLS EACH CAVITY SIDE-TO-SIDE AND TOP-TO-BOTTOM, WITHOUT GAPS OR VOIDS AROUND THAN 2 PERCENT OF THE DESIGN AIRFLOW RATE WHEN TESTED IN ACCORDANCE WITH ASHRAE 193. I TH NTINU US INSULATION RE UIREMENT ALSO SHALL COMPLY WITH SECTION R702.7 OF THE RESIDENTIAL CODE OF NEW OBSTRUCTIONS, AND IS SPLIT, INSTALLED, OR FITTED TIGHTLY AROUND WIRING AND OTHER PENETRATIONS IN THE CAVITY. NO MORE THAN 2 PERCENT THE INTERIOR DESIGN TEMPERATURES 11SED FOR HEATING AND COOLING LOAD CALCULATIONS SHALL BE A MAXIMUM OF 72'F (22'C) FOR HEATING AND WHERE SPECIFED, E CO 0 Q OF THE TOTAL INSULATED AREA SHALL CONTAIN GAPS OR VOIDS IN THE INSULATION OR BE COMPRESSED BELOW THE THICKNESS REQUIRED TO ATTAIN R403.3.7 DUCT SYSTEM TESTING. EACH DUCT SYSTEM SHALL BE TESTED FOR AIR LEAKAGE IN ACCORDANCE WITH ANSI/RESNET/ICC 380 OR ASTM I- p YORK STATE. REPLACEMENT EXTERIOR WALL COVERINGS SHALL COMPLY WITH THE WATER-RESISTANCE REQUIREMENTS OF SECTION R703.1.1 OF THE THE LABELED R-VALUE. MINIMUM OF 75'F (24'C) FOR COOLING E1554. TOTAL LEAKAGE SHALL BE MEASURED WITH A PRESSURE DIFFERENTIAL OF 0.1 INCH WATER GAUGE (25 PA) ACROSS THE DUCT SYSTEM AND cc Q RESIDENTIAL CODE OF NEW YORK STATE OR SECTION 1402.2 OF THE BUILDING CODE OF NEW YORK STATE, AS APPLICABLE, AND MANUFACTURERS' SHALL INCLUDE THE MEASURED LEAKAGE FROM THE SUPPLY AND RETURN DUCTWORK. A WRITTEN REPORT OF THE TEST RESULTS SHALL BE SIGNED BY G O � SECTION R4012 BUILDING THERMAL ENVELOPE INSTRUCTIONS. [NY] R402.5.L2 AIR LEAKAGE TESTING. THE BUILDING OR EACH DWELLING UNIT OR SLEEPING UNIT IN THE BUILDING SHALL BE TESTED FOR AIR THE PARTY CONDUCTING THE TEST AND PROVIDED TO THE BUILDING OFFICIAL. DUCT SYSTEM LEAKAGE TESTING AT EITHER ROUGH-IN OR POST � o0 I IN TH MA ENVELOPE SHALL COMPLY WITH THE VAPOR RETARDER REQUIREMENTS OF 3. WHERE NEW INTERIOR FINISHES OR EXTERIOR WALL COVERINGS ARE APPLIED TO THE FULL EXTENT OF ANY EXTERIOR WALL ASSEMBLY OF MASS LEAKAGE. TESTING SHALL BE CONDUCTED IN ACCORDANCE WITH ANSI/RESNET/ICC 380, ASTM E779, ASTM E1827 OR ASTM E3158 AND REPORTED AT A CONSTRUCTION SHALL BE PERMITTED WITH OR WITHOUT THE INSTALLATION OF REGISTERS OR GRILLES. WHERE INSTALLED, REGISTERS AND GRILLES W 0 M VAPOR RETARDER: WALL ASSEMBLIES IN THE Bu LD G ER L CONSTRUCTION, INSULATION SHALL BE PROVIDED IN ACCORDANCE WITH SECTION R402.1. PRESSURE DIFFERENTIAL OF 0.2 INCH WATER GAUGE (50 PA). WHERE REQUIRED BY THE BUILDING OFFICIAL, TESTING SHALL BE CONDUCTED BY AN SHALL BE SEALED DURING THE TEST. WHERE REGISTERS AND GRILLES ARE NOT INSTALLED, THE FACE OF THE REGISTER BOOTS SHALL BE SEALED O-i } � co SECTfON R702.7 OF THE RESIDENTIAL CODE OF NEW YORK STATE OR SECTION 1404.3 OF THE BUILDING CODE OF NEW YORK STATE, AS APPLICABLE. VAPOR RETARDER MATERIALS SHALL BE CLASSIFIED IN ACCORD4NCE WITH TABLE R702.7(1). A VAPOR RETARDER SHALL BE PROVIDED ON THE [NY] R702.7 VAPOR RETARDERS. INTERIOR SIDE [NY] R503.1.1.4 FLOOR ALTERATIONS. WHERE CAVITIES IN A FLOOR OR FLOOR OVERHANG ARE EXPOSED AND THE FLOOR OR FLOOR OVERHANG IS APPROVED THIRD PARTY., A WRITTEN REPORT OF THE RESULTS OF THE TEST SHALL BE SIGNED BY THE PARTY CONDUCTING THE TEST AND PROVIDED DURING THE TEST. m TO THE BUILDING OFFICIA1L. TESTING SHALL BE PERFORMED AT ANY TIME AFTER CREATION OF ALL PENETRATIONS OF THE BUILDING THERMAL ENVELOPE z O W F- L i OF FRAME WALLS OF THE CLASS INDICATED IN TABLE R702.7(2), INCLUDING COMPLIANCE WITH TABLE R702.7(3) OR R702.7(4} WHERE APPLICABLE. AN APPROVED DESIGN PART OF THE BUILDING THERMAL ENVELOPE, THE CAVITIES SHALL BE INSULATED TO FULL DEPTH WITH NEW OR EXISTING INSULATION THAT COMPLIES EXCEPTIONS: _ = J - USING ACCEPTED ENGINEERING PRACTICE FOR HYGROTHERMAL ANALYSIS SHALL BE PERMITTED AS AN ALTERNATIVE. VAPOR RETARDERS SHALL BE INSTALLED IN ACCORDANCE WITH SECTION R303.1.4. AND HAVING A MINIMUM NOMINAL VALUE OF R-3 PER INCH. NEW CAVITIES CREATED IN THE FLOOR OR FLOOR OVERHANG HAVE SEEN SEALED. p J U) m WITH SECTION R702.7.2. PROVIDE KRAFT-FACED FIBERGLASS BATT INSULATION AT EXTERIOR WALLS IN ACCORDANCE WITH R702.7 OF RCNYS SHALL COMPLY WITH SECTION R402.1.WHERE AN UNCONDITIONED BELOW-GRADE SPACE IS CHANGED TO CONDITIONED SPACE, FLOORS THAT ARE PART OF DURING TESTING: 1. TESTING SHALL NOT BE REQUIRED FOR DUCT SYSTEMS SERVING VENTILATION SYSTEMS THAT ARE NOT INTEGRATED WITH DUCT SYSTEMS SERVING Q Q - cA HEATING OR COOLING SYSTEMS. m W INSULATION AND FENESTRATION CRITERA:COMPLY WITH TABLE R4402.1.3 (BELOW) FOR MINIMUM REQUIREMENTS THE BUILDING THERMAL ENVELOPE ENCLOSING SUCH SPACE SHALL COMPLY WITH SECTION R502. 1. EXTERIOR WINDOWS AND DOORS, FIREPLACE AND STOVE DOORS SHALL BE CLOSED, BUT NOT SEALED, BEYOND THE INTENDED WEATHERSTRIPPING 2. TESTING SHALL NOT BE REQUIRED WHERE THERE IS NOT MORE THAN 10 FEET (3048 MM) OF TOTAL DUCTWORK EXTERNAL TO THE SPACE 2E OR OTHER INFILTRATTION CONTROL MEASURES. [NY] R503.1.1.5 BELOW-GRADE WALL ALTERATIONS. WHERE AN UNCONDITIONED BELOW-GRADE SPACE IS CHANGED TO CONDITIONED SPACE, THE COND1110NING EQUIPMENT AND BOTH THE FOLLOWING ARE MET: Q � [NY]TIABLE R402.1.3 M BUILDING THERMAL ENVELOPE WALLS ENCLOSING SUCH SPACE SHALL COMPLY WITH SECTION R502. WHERE THE BELOW-GRADE SPACE IS CONDITIONED 2. DAMPERS INCLUDING) EXHAUST, INTAKE, MAKEUP AIR, BACKDRAFT AND FLUE DAMPERS SHALL BE CLOSED, BUT NOT SEALED BEYOND INTENDED LO INSULATION MINIMUM N-VALUES AND FENESTRATION SPACE AND WHERE BUILDING THERMAL ENVELOPE WALLS ENCLOSING SUCH SPACE ARE ALTERED, THEY SHALL BE INSULATED IN ACCORDANCE WITH INFILTRATION CONTR?OL MEASURES. 2.1. THE DUCT SYSTEM IS LOCATED ENTIRELY WITHIN CONDITIONED SPACE. V REQUIREMENTS BY COMPONENTa SECTION R402.1. 3. INTERIOR DOORS, WEHERE INSTALLED AT THE TIME OF THE TEST, SHALL BE OPEN. 2.2. THE DUCTWORK DOES NOT INCLUDE PLENUMS CONSTRUCTED OF BUILDING CAVITIES OR GYPSUM BOARD. R503.1.1.6 AIR BARRIER. ALTERED BUILDING THERMAL ENVELOPE ASSEMBLIES SHALL BE PROVIDED WITH AN AIR BARRIER IN ACCORDANCE WITH SECTION 4. EXTERIOR OR INTERIIOR TERMINATIONS FOR CONTINUOUS VENTILATION SYSTEMS SHALL BE SEALED. 3. WHERE THE SPACE CONDITIONING EQUIPMENT IS NOT INSTALLED, TESTING SHALL BE PERMITTED. THE TOTAL MEASURED LEAKAGE OF THE SUPPLY R402.5. SUCH AN AIR BARRIER NEED NOT BE CONTINUOUS WITH UNALTERED PORTIONS OF THE BUILDING THERMAL ENVELOPE. TESTING REQUIREMENTS 5. HEATING AND COOLIING SYSTEMS, WHERE INSTALLED AT THE TIME OF THE TEST, SHALL BE TURNED OFF. AND RETURN DUCTWORK SHALL BE LESS THAN OR EQUAL TO 3.0 CUBIC FEET PER MINUTE (85 L/MIN) PER 100 SQUARE FEET (9.29 M2) OF CLI]viATE ZONE q 5 6 OF SECTION R402.5.1.2 SHALL NOT BE REQUIRED. 6. SUPPLY AND RETURN REGISTERS, WHERE INSTALLED AT THE TIME OF THE TEST, SHALL BE FULLY OPEN. CONDITIONED FLOOR AREA. R503.1.2 HEATING AND COOLING SYSTEMS. NEW HEATING, COOLING AND DUCT SYSTEMS THAT ARE PART OF THE ALTERATION SHALL COMPLY WITH 4. WHERE TESTED IN ACCORDANCE WITH SECTION R403.3.9, TESTING OF EACH DUCT SYSTEM IS NOT REQUIRED. SECTION R403 AND THIS SECTION. ALTERATIONS TO EXISTING HEATING AND COOLING SYSTEMS AND DUCTWORK SHALL COMPLY WITH THIS SECTION. EXCEPTIONS: R403.3.8 DUCT SYSTEM LEAKAGE. THE TOTAL MEASURED DUCT SYSTEM LEAKAGE SHALL NOT BE GREATER THAN THE VALUES IN TABLE R403.3�.8, VERTICAL FENESTRATION EXCEPTION: WHERE DUCTWORK FROM AN EXISTING HEATING AND COOLING SYSTEM IS EXTENDED. 1. FOR HEATED SUNRO)OMS AND HEATED ATTACHED OR DETACHED PRIVATE GARAGES ACCESSORY TO RESIDENTIAL BUILDINGS, BUILDING THERMAL BASED ON THE CONDITIONED FLOOR AREA, NUMBER OF DUCTED RETURNS, AND LOCATION OF THE DUCT SYSTEM. FOR BUILDINGS COMPLYING WIITH U-FACTOR 0.27 0.279 0.27 R503.1.2.1 DUCTWORK. HVAC DUCTWORK NEWLY INSTALLED AS PART OF AN ALTERATION SHALL COMPLY WITH SECTION R403. ENVELOPE TIGHTNESS AND INSULATION INSTALLATION SHALL BE CONSIDERED ACCEPTABLE WHERE THE ITEMS IN TABLE R402.5.1.1, APPLICABLE TO SECTION R405 OR R406, WHERE DUCT SYSTEM LEAKAGE TO OUTSIDE IS TESTED IN ACCORDANCE WITH ANSI/RESNET/ICC 380 OR ASTM E1554, THE THE METHOD OF CONSTRUCTION, ARE FIELD VERIFIED. WHERE REQUIRED BY THE BUILDING OFFICIAL, AN APPROVED THIRD PARTY INDEPENDENT tl,. a . 1 EXCEPTION: WHERE DUCTWORK FROM AN EXISTING HEATING AND COOLING SYSTEM IS EXTENDED. LEAKAGE TO OUTSIDE VALUE SHALL NOT BE USED FOR COMPLIANCE WITH THIS SECTION, BUT SHALL BE PERMITTED TO BE USED IN THE CALCUILATION t .) ,k, FROM THE INSTALLER SHALL INSPECT BOTH AIR BARRIER AND INSULATION INSTALLATION CRITERIA. HEATED SUNROOMS AND HEATED ATTACHED OR PROCEDURES OF SECTION R405 AND R406. ��1 R503.1.2.2 SYSTEM SIZING. NEW HEATING AND COOLING EQUIPMENT THAT IS PART OF AN ALTERATION SHALL BE SIZED IN ACCORDANCE WITH SECTION DETACHED PRIVATE GARAGE SPACE SHALL BE THERMALLY ISOLATED FROM ALL OTHER CONDITIONED SPACES IN ACCORDANCE WITH SECTIONS g '' :_ SKYLIGHT U-FACTOR 0.50 .50 0. R403.7 BASED ON THE EXISTING BUILDING FEATURES AS MODIFIED BY THE ALTERATION. R402.2.13 AND R40)2.4.5, AS APPLICABLE. R403.4 MECHANICAL SYSTEM PIPING INSULATION. MECHANICAL SYSTEM PIPING CAPABLE OF CARRYING FLUIDS GREATER THAN 105E (41'C) OR LESS t' }f_. -, '. THAN 55-F (13'C) SHALL BE INSULATED TO AN R-VALUE OF NOT LESS THAN R-3. - EXCEPTION: WHERE IT HAS BEEN DEMONSTRATED TO THE BUILDING OFFICIAL THAT COMPLIANCE WITH THIS SECTION WOULD RESULT IN HEATING OR 2. WHERE TESTED IN ACCCORDANCE WITH SECTION R402.5.1.2.1, TESTING OF EACH DWELLING UNIT OR SLEEPING UNIT IS NOT REQUIRED. 1 GLAZED VERTICAL 0.40 0. 0 !R COOLING EQUIPMENT THAT IS INCOMPATIBLE WITH THE REMAINING PORTIONS OF THE EXISTING HEATING OR COOLING SYSTEM. -1-1 FENESTRATION SHGC [NY] R402.5.1.3 MAXIMWM AIR LEAKAGE RAIT=. THE AIR LEAKAGE RATE FOR BUILDINGS, DWELLING UNITS OR SLEEPING UNITS SHALL BE NOT GREATER R503.1.2.3 DUCT SYSTEM LEAKAGE. WHERE AN ALTERATION INCLUDES ANY OF THE FOLLOWING, DUCT SYSTEMS SHALL BE TESTED IN ACCORDANCE WITH THAN 3.0 AIR CHANGES IPER HOUR IN CLIMATE ZONES 4 AND 5, OR 0.19 CUBIC FOOT [1.1AS xM2)] OF THE BUILDING THERMAL ENVELOPE AREA; AND R403.4.1 PROTECTION OF PIPING INSULATION. PIPING INSULATION EXPOSED TO WEATHER SHALL BE PROTECTED FROM DAMAGE, INCLUDING THAT iCAUSED SECTION R403.3.7 AND SHALL HAVE A TOTAL LEAKAGE LESS THAN OR EQUAL TO 12.0 CUBIC FEET PER MINUTE (339.9 L/MIN) PER 100 SQUARE FEET NOT GREATER THAN 2.5 AIR CHANGES PER HOUR IN CLIMATE ZONE 6, OR 0.16 CUBIC FOOT [O.8AS xM2)] OF THE BUILDING THERMAL ENVELOPE AREA. BY SUNLIGHT, MOISTURE, PHYSICAL CONTACT AND WIND. THE PROTECTION SHALL PROVIDE SHIELDING FROM SOLAR RADIATION THAT CAN CAUSE SKYLIGHT SHGC 0.40 N NR (9.29 M2) OF CONDITIONED FLOOR AREA: DEGRADATION OF THE MATERIAL AND SHALL BE REMOVABLE NOT LESS THAN 6 FEET (1828 MM) FROM THE EQUIPMENT FOR MAINTENANCE. ADHESIVE EXCEPTIONS: TAPE SHALL BE PROHIBITED. - IST R THAT ARE PART OF THE DUCT SYSTEM ARE RELOCATED. 1. TWENTY FIVE PERCENT OR MORE OF THE REG E S 1. WHERE DWELLING UNVITS OR SLEEPING UNITS ARE ATTACHED OR LOCATED IN AN R-2 OCCUPANCY, AND ARE TESTED WITHOUT SIMULTANEOUSLY CEILING R-VALUE 49 49 49 2. TWENTY-FIVE PERCENT OR MORE OF THE TOTAL LENGTH OF ALL DUCTWORK IN THE DUCT SYSTEM IS RELOCATED. TESTING ADJACENT IDWELUNG UNITS OR SLEEPING UNITS, THE AIR LEAKAGE RATE IS PERMITTED TO BE NOT GREATER THAN 0.27 CUBIC FEET PER R403.5 SERVICE HOT WATER SYSTEMS. ENERGY CONSERVATION MEASURES FOR SERVICE HOT WATER SYSTEMS SHALL BE IN ACCORDANCE WITH SECTIONS INSULATION ENTIRELY 3. THE TOTAL LENGTH OF ALL DUCTWORK IN THE DUCT SYSTEM IS INCREASED BY 25 PERCENT OR MORE. MINUTE PER SQUARE FOOT [1.4 LAS xM2)] OF THE TESTING UNIT ENCLOSURE AREA. WHERE ADJACENT DWELLING UNITS ARE SIMULTANEOUSLY R403.5.1 THROUGH TER C.3. ABOVE ROOF DECK 30ci 30ci 30ci R403.5.1 HEATED WATER CIRCULATION AND TEMPERATURE MAINTENANCE SYSTEMS. HEATED WATER CIRCULATION SYSTEMS SHALL BE IN f Y TT.D 7,l EXCEPTION: DUCT SYSTEMS LOCATED ENTIRELY INSIDE A CONDITIONED SPACE IN ACCORDANCE WITH SECTION R403.3.4. TESTED IN ACCORDAANCE WITH ASTM E779, THE AIR LEAKAGE RATE IS PERMITTED TO BE NOT GREATER THAN 0.27 CUBIC FEET PER MINUTE PER SQUARE FOOT [1.4 ILAS xM2)] OF THE TESTING UNIT ENCLOSURE AREA THAT SEPARATES CONDITIONED SPACE FROM 1HE EXTERIOR. ACCORDANCE WITH SECTION R403.5.1.1. HEAT TRACE TEMPERATURE MAINTENANCE SYSTEMS SHALL BE IN ACCORDANCE WITH SECTION R403.5.1.2'. ,-,�+,tJ ___ ` �. 30 OR 30 OR 30 OR R503.1.2.4 CONTROLS. NEW HEATING AND COOLING EQUIPMENT THAT IS PART OF THE ALTERATION SHALL COMPLY WITH SECTIONS R403.1 AND R403.2. AUTOMATIC CONTROLS, TEMPERATURE SENSORS AND PUMPS SHALL BE IN A LOCATION WITH ACCESS. MANUAL CONTROLS SHALL BE IN A LOCATION WITH ' ;.1^-_ L_� ," WOOD FRAMED WALL 20&5ci OR 20&5ci OR 20&5ci OR 2. WHERE BUILDINGS WAVE 1,500 SQUARE FEET (139.4 M2) OR LESS OF CONDITIONED FLOOR AREA, THE AIR LEAKAGE RATE IS PERMITTED TO BE NOT READY ACCESS. _ � R503.1.3 SERVICE HOT WATER SYSTEMS. NEW SERVICE HOT WATER SYSTEMS THAT ARE PART OF THE ALTERATION SHALL COMPLY WITH SECTION R403.5. " �.. . GREATER THAN 0.271 CUBIC FEET PER MINUTE PER SQUARE FOOT 1.4 L S xM2 OF THE TESTING UNIT ENCLOSURE AREA. y,.. ^ ! �• / R-VALUEe 13&1Oci OR 13&10ci 0 " 13&10ci OR R503.1.4 LIGHTING. NEW LIGHTING SYSTEMS THAT ARE PART OF THE ALTERATION SHALL COMPLY WITH SECTION R404.1. [ /( )] R403.5.1.1 CIRCULATION SYSTEMS. HEATED WATER CIRCULATION SYSTEMS SHALL BE PROVIDED WITH A CIRCULATION PUMP. GRAVITY AND THERMO'SYPHON ri_: �w 0&20ci O&2Oci 0&20ci R402.5.2 FIREPLACES. CIRCULATION SYSTEMS SHALL BE PROHIBITED. CONTROLS FOR CIRCULATING HOT WATER SYSTEM PUMPS SHALL AUTOMATICALLY TURN OFF THE PUMP I , I � � =.,... a * EXCEPTION: ALTERATIONS THAT REPLACE LESS THAN 10 PERCENT OF THE LUMINAIRES IN A SPACE, PROVIDED THAT SUCH ALTERATIONS DO NOT `` �4 ��� ,; , INCREASE THE INSTALLED INTERIOR LIGHTING POWER. NEW WOOD-BURNING FIfiREPLACES SHALL HAVE TIGHT-FITTING FLUE DAMPERS OR DOORS, AND OUTDOOR COMBUS110N AIR. WHERE USING WHEN THE WATER IN THE CIRCULATION LOOP IS AT THE DESIRED TEMPERATURE AND WHEN THERE IS NO DEMAND FOR HOT WATER THE SYSTEMI RETURN .,'._. PIPE SHALL BE A DEDICATED RETURN PIPE OR A COLD WATER SUPPLY PIPE. WHERE A COLD WATER SUPPLY PIPE IS USED AS THE RETURN PIPE, A �P • , './'l�- MASS WALL R-VALUEf 15/20 15/20 15/20 R503.1.5 ADDITIONAL EFFICIENCY CREDIT REQUIREMENTS FOR SUBSTANTIAL IMPROVEMENTS. SUBSTANTIAL IMPROVEMENTS SHALL COMPLY WITH SUFFICIENT TIGHT-FITTING DOORS ON FACTORY-BUILT FIREPLACES LISTED AND LABELED IN ACCORDANCE WITH UL 127, THE DOORS SHALL BE TESTED AND , 7A`l�.,vs{ ,, f 16._ LISTED FOR THE FIREPLACE. TEMPERATURE SENSOR CONNECTED TO THE CONTROLS SHALL BE LOCATED ON THE HOT WATER SUPPLY NOT MORE THAN TWO FEET (305 MM) FROM _ -_ - Cj 30 OR 30 0 0 OR MEASURES FROM TABLE R408.2 TO ACHIEVE NOT LESS THAN THREE CREDITS. THE CONNECTION TO THE COLD WATER SUPPLY PIPE. THE CONTROLS SHALL LIMIT THE TEMPERATURE OF THE WATER ENTERING THE COLD WATER PIPING , 0;r- P.�,_`Tj _' / FLOOR R-VALU(P 19&7.56 OR 19&7.5 OR 19 7.5ci OR EXCEPTIONS: R402.5.3 FENESTRATION) AIR LEAKAGE. TO NOT GREATER THAN 104-F (40'C). _______ 20ci 20 Oci 1. ALTERATIONS THAT ARE PERMITTED WITH AN ADDITION COMPLYING WITH SECTION R502.2.5. WINDOWS, SKYLIGHTS ANND SLIDING GLASS DOORS SHALL HAVE AN AIR INFILTRATION RATE OF NO MORE THAN 0.3 CFM PER SQUARE FOOT (1.5 R403.5.1.1.1 DEMAND RECIRCULATION WATER SYSTEMS. DEMAND RECIRCULATION WATER SYSTEMS SHALL HAVE CONTROLS THAT START THE PUMP UPON 15ci OR 156 R 1 i OR 2. ALTERATIONS THAT COMPLY WITH SECTION R405 OR R406. L/S/M2), AND SWINGING DOORS NO MORE THAN 0.5 CFM PER SQUARE FOOT (2.6 L/S/M2), WHEN TESTED ACCORDING TO NFRC 400 OR RECEIVING A SIGNAL FROM THE ACTION OF A USER OF A FIXTURE OR APPLIANCE, SENSING THE PRESENCE OF A USER OF A FIXTURE OR SENSING THE BASEMENT WALL R-VALUE�'e 19 OR 19 R 1 OR 3. SUBSTANTIAL IMPROVEMENTS THAT DO NOT INCLUDE THE ADDITION OR REPLACEMENT OF EQUIPMENT COVERED IN EITHER SECTION R403.5 OR AAMA/WDMA/CSA 101/1'I.S.2/A440 BY AN ACCREDITED, INDEPENDENT LABORATORY AND LISTED AND LABELED BY THE MANUFACTURER. FLOW OF HOT OR TEMPERED WATER TO A FIXTURE FITTING OR APPLIANCE. THE CONTROLS SHALL LIMIT PUMP OPERATION BY: N 13&5ci 13 5ci 13 5ci R403.7. EXCEPTION: SITE-BUILT- WINDOWS, SKYLIGHTS AND DOORS. 1. SHUTTING OFF THE PUMP WHEN THE TEMPERATURE SENSOR DETECTS ONE OF THE FOLLOWING: .� SECTION R504 REPAIRS R402.5.4 RECESSED LIGHITING. RECESSED LUMINAIRES INSTALLED IN THE BUILDING THERMAL ENVELOPE SHALL BE SEALED TO LIMIT AIR LEAKAGE 1.1• AN INCREASE IN THE WATER TEMPERATURE OF NOT MORE THAN 10'F (5.6'C) ABOVE THE INITIAL TEMPERATURE OF THE N +, cy) OU UNHEATED SLAB R-VALUE loci, 4FT 10 i, 4FT l Oci, FT & DEPTH` R504.1 GENERAL. BUILDINGS, STRUCTURES AND PARTS THEREOF SHALL BE REPAIRED IN COMPLIANCE WITH SECTION R501.3 AND THIS SECTION. WORK BETWEEN CONDITIONED A1ND UNCONDITIONED SPACES. RECESSED LUMINAIRES SHALL BE IC-RATED AND LABELED AS HAVING AN AIR LEAKAGE RATE OF WATER IN THE PIPE. L N � N ON NONDAMAGED COMPONENTS NECESSARY FOR THE REQUIRED REPAIR OF DAMAGED COMPONENTS SHALL BE CONSIDERED TO BE PART OF THE REPAIR NOT GREATER THAN 2.0 CFM (0.944 L/S) WHEN TESTED IN ACCORDANCE WITH ASTM E283 AT A PRESSURE DIFFERENTIAL OF 1.57 PSF (75 PA). 1.2. THE TEMPERATURE OF THE WATER IN THE PIPE REACHES 104-F (40'C). U - c- O 3 R-106, 4FT R lOci, 4FT R-106, FT AND SHALL NOT BE SUBJECT TO THE REQUIREMENTS FOR ALTERATIONS IN THIS CHAPTER. ROUTINE MAINTENANCE REQUIRED BY SECTION R501.3, RECESSED LUMINAIRES SFHALL BE SEALED WITH A GASKET OR CAULKED BETWEEN THE HOUSING AND THE INTERIOR WALL OR CEILING COVERING. Q (n r 64 U HEATED STAB R-VALUE AND AND AND ORDINARY REPAIRS EXEMPT FROM PERMIT, AND ABATEMENT OF WEAR DUE TO NORMAL SERVICE CONDITIONS. SHALL NOT BE SUBJECT TO THE 2. LIMITING PUMP OPERATION TO A MAXIMUM OF 5 MINUTES FOLLOWING ACTIVATION. R402.5.5 AIR-SEALED ELECTRICAL AND COMMUNICATION OUTLET BOXES. AIR-SEALED ELECTRICAL AND COMMUNICATION OUTLET BOXES THAT � �- � & DEPTH REQUIREMENTS FOR REPAIRS IN THIS SECTION. 3. NOT ACTIVATING THE PUMP FOR AT LEAST 5 MINUTES FOLLOWING SHUTOFF OR WHEN THE TEMPERATURE OF THE WATER IN THE PIPE EXCEEDS >+ •- R-10 FULL SlA6 10 FULL SLAB R-10 FULL B PENETRATED THE AIR BAWRRIER OF THE BUILDING THERMAL ENVELOPE SHALL BE CAULKED, TAPED, GASKETED OR OTHERWISE SEALED TO THE AIR �C Z ti - 104-F (40'C). R504.2 APPLICATION. FOR THE PURPOSES OF THIS CODE, THE FOLLOW"DING SHALL BE CONSIDERED TO BE REPAIRS: BARRIER ELEMENT BEING PENETRATED. AIR-SEALED BOXES SHALL BE BURIED IN OR SURROUNDED BY INSULATION. AIR-SEALED BOXES SHALL BE i 156 OR 156 OR 156 OR > C ti CRAWL SFACE WALL R-VALUEb'e 19 OR 19 OR 19 OR 1. GLASS-ONLY REPLACEMENTS IN AN EXISTING SASH AND FRAME. TESTED AND MARKED IN ACCORDANCE WITH NEMA OS 4. AIR-SEALED BOXES SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS R403.5.1.2 HEAT TRACE SYSTEMS. ELECTRIC HEAT TRACE SYSTEMS SHALL COMPLY WITH IEEE 515.1 OR UL 515. CONTROLS FOR SUCH SYSTEMS. SHALL O 4r O Cu INSTRUCTIONS. AUTOMATICALLY ADJUST THE ENERGY INPUT TO THE HEAT TRACING TO MAINTAIN THE DESIRED WATER TEMPERATURE IN THE PIPING IN ACCORDANICE WITH _.a to -+-� 1 13&5ci 13&5ci 13&5ci 2. ROOF REPAIRS. THE TIMES WHEN HEATED WATER IS USED IN THE OCCUPANCY. �'' (� M [NY] R402.5.6 TENANT SEPARATION WALLS. WALL AND FLOOR ASSEMBLIES BETWEEN DWELLING UNITS IN TWO-FAMILY DWELLINGS AND TOWNHOUSES N W S Cfl 3. REPAIRS WHERE ONLY THE BULB, BALLAST OR BOTH WITHIN THE EXISTING LUMINAIRES IN A SPACE ARE REPLACED PROVIDED THAT THE SHALL BE INSULATED TOE NO LESS THAN R-10 AND AIR SEALED IN ACCORDANCE WITH SECTION R402.5.1.1 AND TABLE R402.5.1.1. WHERE INSTALLED IN R403.5.2 HOT WATER PIPE INSULATION. INSULATION FOR SERVICE HOT WATER PIPING SHALL COMPLY WITH TABLE R403.5.2 AND BE APPLIED TO THE -J ',- • • � PROJECT SPECIFIC BUILDING THERMAL, ENVELOPE REQUIREMENTS IN ACCORDANCE WITH R402.1.3: REPLACEMENT DOES NOT INCREASE THE INSTALLED INTERIOR LIGHTING POWER. FOLLOWING: U) CD C F-- (6 A FIRE-RESISTANCE-RA1[ED WALL OR FLOOR ASSEMBLY, INSULATION SHALL COMPLY WITH ONE OF THE FOLLOWING: PROPOSED EXTERIOR WALLS: CLOSED CELL SPRAY FOAM (R-20 MIN.) + R-5 CONTINUOUS RIGID INSULATION SECTION R402 1. BE IN ACCORDANCE WITH AN APPROVED DESIGN FOR THE FIRE-RESISTANCE-RATED ASSEMBLY. 1. PIPING 3/4 INCH (19.1 MM) AND LARGER IN NOMINAL DIAMETER LOCATED INSIDE THE CONDITIONED SPACE. N - _ L_ CEILINGS: 14" R-49 FIBERGLAS`.i INSULATION R402.2 SPECIFIC INSULATION REQUIREMENTS. IN ADDITION TO THE REQUIREMENTS OF SECTION R402.1, INSULATION SHALL MEET THE SPECIFIC 2. BE SUPPORTED BY APPROVED DATA THAT SHOWS THE ASSEMBLY AS INSTALLED COMPLIES WITH THE REQUIRED FIRE-RESISTANCE RATING. 2. PIPING LOCATED OUTSIDE THE CONDITIONED SPACE. � FLOORS: 9.5" R-30 FIBERGLASS INSULATION REQUIREMENTS OF SECTIONS R402.2.1 THROUGH R402.2.13. [NY] R402.6 MAXIMUM IFENESTRATION U-FACTOR. THE AREA-WEIGHTED AVERAGE MAXIMUM FENESTRATION U-FACTOR PERMITTED USING TRADEOFFS 3. PIPING FROM THE WATER HEATER TO A DISTRIBUTION MANIFOLD. Q (u FENESTRATION: U=.27 (MAX) [NY] R402.2.1 CEILINGS WITH ATTICS. WHERE SECTION R402.1.3 REQUIRES R-49 INSULATION IN THE CEILING OR ATTIC, INSTALLING R-38 OVER 100 FROM SECTION R402.1.5 OR R405 SHALL BE 0.45 IN CLIMATE ZONES 4 AND 5 AND 0.37 IN CLIMATE ZONE 6 FOR VERTICAL FENESTRATION, AND 0.72 4. PIPING LOCATED UNDER A FLOOR SLAB. NYSECCC CHAPTER 5 EXISTING BUILDINGS PERCENT OF THE CEILING OR ATTIC AREA REQUIRING INSULATION SHALL SATISFY THE REQUIREMENT FOR R-49 INSULATION WHEREVER THE FULL HEIGHT IN CLIMATE ZONES 4 THFROUGH 6 FOR SKYLIGHTS. 5. BURIED PIPING. OF UNCOMPRESSED R-38 INSULATION EXTENDS OVER THE WALL TOP PLATE AT THE EAVES. THIS REDUCTION SHALL NOT APPLY TO THE INSULATION AND EXCEPTION: THE MAXIMUNM U-FACTOR FOR FENESTRATION SHALL NOT BE REQUIRED IN STORM SHELTERS COMPLYING WITH ICC 500. R501.1.1 GENERAL. EXCEPT AS SPECIFIED IN THIS CHAPTER, THIS CODE SHALL NOT BE USED TO REQUIRE THE REMOVAL, ALTERATION FENESTRATION CRITERIA IN SECTION R402.1.2 AND THE COMPONENT PERFORMANCE ALTERNATIVE IN SECTION R402.1.5. 6. SUPPLY AND RETURN PIPING IN CIRCULATING HOT WATER SYSTEMS. OR ABANDONMENT OF, NOR PREVENT THE CONTINUED USE AND, MAINTENANCE OF, AN EXISTING BUILDING OR BUILDING SYSTEM LAWFULLY IN EXISTENCE [NY] R402.2.2 CEILINGS WITHOUT ATTICS. WHERE SECTION R402.1.3 REQUIRES INSULATION R-VALUES GREATER THAN R-38 IN THE INTERSTITIAL SPACE SECTION R403 SYSTEMS EXCEPTION: COLD WATER RETURNS IN DEMAND RECIRCULATION WATER SYSTEMS. AT THE TIME OF ADOPTION OF THIS CODE. ABOVE A CEILING AND BELOW THE STRUCTURAL ROOF DECK, AND THE DESIGN OF THE ROOF/CEILING ASSEMBLY DOES NOT ALLOW SUFFICIENT SPACE R403.1 CONTROLS. NOT LLESS THAN ONE THERMOSTAT SHALL BE PROVIDED FOR EACH SEPARATE HEATING AND COOLING SYSTEM. R403.5.3 DRAIN WATER HEAT RECOVERY UNITS. WHERE INSTALLED, DRAIN WATER HEAT RECOVERY UNITS SHALL COMPLY WITH CSA B55.2. DRAIN WATER O NY R501.2 COMPLIANCE. ALTERATIONS REPAIRS, ADDITIONS /AND CHANGES OF OCCUPANCY TO, OR RELOCATION OF, EXISTING BUILDINGS AND FOR THE REQUIRED INSULATION, THE MINIMUM REQUIRED INSULATION R-VALUE FOR SUCH ROOF/CEILING ASSEMBLIES SHALL BE R-38. INSULATION R403.1.1 PROGRAMMABLE' THERMOSTAT. THE THERMOSTAT CONTROLLING THE PRIMARY HEATING OR COOLING SYSTEM OF THE DWELLING UNIT SHALL BE HEAT RECOVERY UNITS SHALL BE TESTED IN ACCORDANCE WITH CSA B55.1. POTABLE WATER-SIDE PRESSURE LOSS OF DRAIN WATER HEAT RECOVERY ST UCTURES SHALL COMPLY WITH THE PROVISIONS FOR ALTERAITIONS, REPAIRS, ADDITIONS AND CHANGES OF OCCUPANCY OR RELOCATION, RESPECTIVELY, SHALL EXTEND OVER THE TOP QF THE WALL PLATE TO THE OUTER EDGE OF SUCH PLATE AND SHALL NOT BE COMPRESSED. THIS REDUCTION OF CAPABLE OF CONTROLUNJG THE HEATING AND COOLING SYSTEM ON A DAILY SCHEDULE TO MAINTAIN DIFFERENT TEMPERATURE SET POINTS AT UNITS SHALL BE LESS THAN 3 PSI (20.7 KPA) FOR INDIVIDUAL UNITS CONNECTED TO ONE OR TWO SHOWERS. POTABLE WATER-SIDE PRESSURE LOSS IN THIS CODE AND THE RESIDENTIAL CODE OF NEW YORK STATEE, BUILDING CODE OF NEW YORK STATE, EXISTING BUILDING CODE OF NEW YORK STATE, INSULATION FROM THE REQUIREMENTS OF SECTION R402.1.3 SHALL BE LIMITED TO 500 SQUARE FEET (46 M2) OR 20 PERCENT OF THE TOTAL DIFFERENT TIMES OF DAYY AND DIFFERENT DAYS OF THE WEEK. THIS THERMOSTAT SHALL INCLUDE THE CAPABILITY TO SET BACK QR TEMPORARILY OF DRAIN WATER HEAT RECOVERY UNITS SHALL BE LESS THAN 2 PSI (13.8 KPA) FOR INDIVIDUAL UNITS CONNECTED TO THREE OR MORE SHOWERS. _z m FIRE CODE OF NEW YORK STATE, FUEL_ GAS CODE OF NEW YOR2K STATE, MECHANICAL CODE OF NEW YORK STATE, PLUMBING CODE OF NEW YORK INSULATED CEILING AREA, WHICHEVER IS LESS. THIS REDUCTION SHALL NOT APPLY TO THE COMPONENT PERFORMANCE ALTERNATIVE IN SECTION OPERATE THE SYSTEM TCO MAINTAIN ZONE TEMPERATURES OF NOT LESS THAN 55-F (13'C) TO NOT GREATER THAN 85-F (29'C). THE THERMOSTAT SHALL [NY] R403.5.4 DEMAND RESPONSIVE WATER HEATING. ALL ELECTRIC STORAGE WATER HEATERS WITH A RATED WATER STORAGE VOLUME OF 40 GALLONS M STATE, PROPERTY MAINTENANCE CODE OF NEW YORK STATE AN[D NFPA 70. R402.1.5. BE PROGRAMMED INITIALLLY BY THE MANUFACTURER WITH A HEATING TEMPERATURE SETPOINT OF NOT GREATER THAN 70-F (21'C) AND A COOLING (15OL) TO 120 GALLONS (450L) AND A NAMEPLATE INPUT RATING EQUAL TO OR LESS THAN 12KW SHALL BE PROVIDED WITH DEMAND RESPONSIVE � T_ SECCTION R502 ADDITIONS R402.2.3 ATTIC KNEE WALL. WOOD ATTIC KNEE WALL ASSEMBLIES THAT SEPARATE CONDITIONED SPACE FROM UNCONDITIONED ATTIC SPACES SHALL TEMPERATURE SETPOINT OF NOT LESS THAN 78-F (26'C). CONTROLS IN ACCORDANCE WITH TABLE R403.5.4. '^ � R502.1 GENERAL. ADDITIONS TO AN EXISTING BUILDING, BUILDINJG SYSTEM OR PORTION THEREOF SHALL CONFORM TO THE PROVISIONS OF THIS CODE AS COMPLY WITH TABLE R402.1.3 FOR WOOD FRAMED WALLS. STEEL ATTIC KNEE WALL ASSEMBLIES SHALL COMPLY WITH SECTION R402.2.7. SUCH KNEE [NY] R403.1.2 HEAT PUJPP SUPPLEMENTARY HEAT. WHERE PERMITTED, HEAT PUMPS HAVING SUPPLEMENTARY ELECTRIC-RESISTANCE, FUEL GAS OR EXCEPTIONS: ''U^) THOSE PROVISIONS RELATE TO NEW CONSTRUCTION WITHOUT REQUIRING THE UNALTERED PORTION OF THE EXISTING BUILDING OR BUILDING SYSTEM TO WALLS SHALL HAVE AN AIR BARRIER BETWEEN CONDITIONED AND UNCONDITIONED SPACE. LIQUID FUEL HEATING SY°STEMS SHALL HAVE CONTROLS THAT ARE CONFIGURED TO PREVENT SUPPLEMENTAL HEAT OPERATION WHEN THE CAPACITY OF Cn 1. WATER HEATERS THAT ARE CAPABLE OF DELIVERING WATER AT A TEMPERATURE OF 180'F (82'C) OR GREATER. Z COMPLY WITH THIS CODE. ADDITIONS `SHALL NOT CREATE AN UNSAFE OR HAZARDOUS CONDITION OR OVERLOAD EXISTING BUILDING SYSTEMS. R402.2.3.1 ROOF TRUSS FRAMING SEPARATING CONDITIONED AND UNCONDITIONED SPACE. WHERE WOOD VERTICAL ROOF TRUSS FRAMING MEMBERS ARE THE HEAT PUMP COMPRESSOR CAN MEET THE HEATING LOAD. SUPPLEMENTAL HEAT OPERATION SHALL BE LIMITED TO ONLY WHERE ONE OF THE ui USED TO SEPARATE CONDITIONED SPACE AND UNCONDITIONED SPACE, THEY SHALL COMPLY WITH TABLE R402.1.3 FOR WOODFRAMED WALLS. STEEL FOLLOWING APPLIES: 2. WATER HEATERS THAT COMPLY WITH SECTION IV, PART HLW OR SECTION X OF THE ASME BOILER AND PRESSURE VESSEL CODE. 00-0 z R502.2 PRESCRIPTIVE COMPLIANCE. ACDITIONS SHALL COMPLY WNITH SECTIONS R502.2.1 THROUGH R502.2.5 FRAME VERTICAL ROOF TRUSS FRAMING MEMBERS USED TO SEPARATE CONDITIONED SPACE AND UNCONDITIONED SPACE SHALL COMPLY WITH SECTION 3. WATER HEATERS THAT USE 3-PHASE ELECTRIC POWER. R502.2.1 BUILDING THERMAL ENVELOP_ NEW BUILDING THERMAI"L ENVELOPE ASSEMBLIES THAT ARE PART OF THE ADDITION SHALL COMPLY WITH SECTIONS FRAME V 1. THE VAPOR COMPRESSION CYCLE CANNOT PROVIDE THE NECESSARY HEATING ENERGY TO SATISFY THE THERMOSTAT SETTING. (� O R402.1, R402.2, R402.4.1 THROUGH R402.4.5, AND R402.5. 2. THE HEAT PUMP IS OPERATING IN DEFROST MODE. [NY] R403.6 MECHANICAL VENTILATION. THE BUILDINGS AND DWELLING UNITS COMPLYING WITH SECTION R402.5.1.1 SHALL BE PROVIDED WITH v Of R402.2.4 EAVE BAFFLE. FOR AIR-PERMEABLE INSULATION IN VENTED ATTICS, A BAFFLE SHALL BE INSTALLED ADJACENT TO SOFFIT AND EAVE VENTS. MECHANICAL VENTILATION THAT COMPLIES WITH THE REQUIREMENTS OF SECTION M1505 OF THE RESIDENTIAL CODE OF NEW YORK STATE, MECHANICAL W EXCEPTION: NEW BUILDING THERMAL ENVELOPE ASSEMBLIES ARE EXEMPT FROM THE REQUIREMENTS OF SECTION R402.5.1.2. BAFFLES SHALL MAINTAIN A NET FREE AREA OPENING EQUAL TO OR GREATER THAN THE SIZE OF THE VENT. THE BAFFLE SHALL EXTEND OVER THE TOP 3. THE VAPOR COMPRESSION CYCLE MALFUNCTIONS. CODE OF NEW YORK STATE, OR NEW YORK CITY CONSTRUCTION CODE, AS APPLICABLE, OR WITH OTHER APPROVED MEANS OF VENTILATION. OUTDOOR Q R502.2.2 HEATING AND COOLING SYSTEMS. HVAC DUCTWORK NEWLY INSTALLED AS PART OF AN ADDITION SHALL COMPLY WITH SECTION R403. OF THE ATTIC INSULATION. THE BAFFLE SHALL BE PERMITTED TO BE ANY SOL►D MATERIAL. THE BAFFLE SHALL BE INSTALLED TO THE OUTER EDGE OF 4. THE THERMOSTAT ViALFUNCTIONS. AIR INTAKES AND EXHAUSTS SHALL HAVE AUTOMATIC OR GRAVITY DAMPERS THAT CLOSE WHEN THE VENTILATION SYSTEM IS NOT OPERATING. \ 2 RK FROM AN EXISTING HEATING AND) COOLING SYSTEM IS EXTENDED TO AN ADDITION, SECTIONS R403.3.7 AND R403.3.8 THE EXTERIOR WALL TOP PLATE SO AS TO PROVIDE MAXIMUM SPACE FOR ATTIC INSULATION COVERAGE OVER THE TOP PLATE. WHERE SOFFIT VENTING IS R403.2 HOT WATER BOILEER TEMPERATURE RESET. OTHER THAN WHERE EQUIPPED WITH TANKLESS DOMESTIC WATER HEATING COILS, THE MANUFACTURER R403.6.2 FAN FFICACY FOR WHOL -HOU M HANI A EXCEPTION: WHERE DUCTWO E E SE EC C L VENTILATION SYSTEMS AND OUTDOOR AIR VENTILATION SYSTEMS. FANS USED TO PROVIDE Z � (- SHALL NOT BE REQUIRED. NOT CONTINUOUS, BAFFLES SHALL BE INSTALLED CONTINUOUSLY TO PREVENT VENTILATION AIR IN THE EAVE SOFFIT FROM BYPASSING THE BAFFLE. SHALL EQUIP EACH GAS, LIQUID FUEL AND ELECTRIC BOILER WITH AUTOMATIC MEANS OF ADJUSTING THE WATER TEMPERATURE SUPPLIED BY THE WHOLE-DWELLING MECHANICAL VENTILATION SHALL MEET THE EFFICACY REQUIREMENTS OF TABLE R403.6.2 AT ONE OR MORE RATING POINTS. FANS (n T M TAT AR PART OF TH ADDITION SHALL COMPLY WITH SECTION R403.5. NY R402.2.5 ACCESS HATCHES AND DOORS. ACCESS HATCHES AND DOORS FROM CONDITIONED TO UNCONDITIONED SPACES SUCH AS ATTICS AND BOILER SO THAT INCREMEENTAL CHANGE OF THE INFERRED HEAT LOAD WILL CAUSE AN INCREMENTAL CHANGE IN THE TEMPERATURE OF THE WATER SHALL BE TESTED IN ACCORDANCE WITH THE TEST PROCEDURE REFERENCED BY TABLE R403.6.2 AND LISTED. THE AIRFLOW SHALL BE REPORTED IN THE O Z R502.2.3 SERVICE HOT WATER SYSTEMS. NEW SERVICE HOT WAITER SYS E S H E E [ ] _ O Q CRAWL SPACES SHALL BE INSULATED TO THE SAME R-VALUE REQUIRED BY TABLE R402.1.3 FOR THE WALL OR CEILING IN WHICH THEY ARE INSTALLED. SUPPLIED BY THE BOILERR. THIS CAN BE ACCOMPLISHED WITH OUTDOOR RESET, INDOOR RESET OR WATER TEMPERATURE SENSING. PRODUCT LISTING OR ON THE LABEL. FAN EFFICACY SHALL BE REPORTED IN THE PRODUCT LISTING OR SHALL BE DERIVED FROM THE INPUT POWER L W [NY] R502.2.4 LIGHTING. NEW LIGHTING SYSTEMS THAT ARE PAART OF THE ADDITION SHALL COMPLY WITH SECTION R404.1 THROUGH R404.3.1. AND AIRFLOW VALUES REPORTED IN THE PRODUCT LISTING OR ON THE LABEL. FAN EFFICACY FOR FULLY DUCTED HRV, ERV, BALANCED VENTILATION I- I NICY CREDIT RE UIREMENTS FOR ADDITIONS. ADDITIONS SHALL COMPLY WITH SUFFICIENT MEASURES FROM TABLE EXCEPTIONS: [NY] R403.3 DUCT SYSTTEMS. DUCT SYSTEMS SHALL BE INSTALLED IN ACCORDANCE W9TH SEC110NS R403.3.1 THROUGH R403.3.9. THE DUCT SYSTEM IN - - U R502.2.5 ADDITIONAL ENERGY EFFIC E Q NEW BUILDINGS AND ADDDITIONS SHALL BE LOCATED IN CONDITIONED SPACE IN ACCORDANCE WITH SECTION R403.3.4. SYSTEMS AND IN LINE FANS SHALL BE DETERMINED AT A STATIC PRESSURE OF NOT LESS THAN 0.2 INCH WATER GAUGE (50 PA). FAN EFFICACY FOR R408.2 TO ACHIEVE NOT LESS THAN FIVE CREDITS. ALTERATIONS TO THE EXISTING BUILDING THAT ARE NOT PART OF THE ADDITION BUT ARE PERMITTED 1. VERTICAL DOORS PROVIDING ACCESS FROM CONDITIONED SPACES TO UNCONDITIONED SPACES THAT COMPLY WITH THE FENESTRATION REQUIREMENTS J OF TABLE R402.1.3 BASED ON THE APPLICABLE CLIMATE ZONE SPECIFIED IN CHAPTER 3. EXCEPTION: VENTILATION DUCTWORK THAT IS NOT INTEGRATED WITH DUCT SYSTEMS SERVING HEATING OR COOLING SYSTEMS. DUCTED RANGE HOODS, BATHROOM AND UTILITY ROOM FANS SHALL BE DETERMINED AT A STATIC PRESSURE OF NOT LESS THAN 0.1 INCH WATER GAUGE WITH AN ADDITION SHALL BE PERMIITI'D TO BE USED TO ACHIEVE THIS REQUIREMENT. (25 PA) � Q W � EXCEPTIONS: 2. HORIZONTAL PULL-DOWN, STAIR-TYPE ACCESS HATCHES IN CEILING ASSEMBLIES THAT PROVIDE ACCESS FROM CONDITIONED TO UNCONDITIONED [NY] R403.3.1 DUCT SYYSTEM DESIGN. DUCT SYSTEMS SERVING ONE OR TWO DWELLING UNITS OR SLEEPING UNITS SHALL BE DESIGNED AND SIZED IN m SPACES IN CLIMATE ZONE 4 SHALL NOT BE REQUIRED TO COMPLY WITH THE INSULATION LEVEL OF THE SURROUNDING SURFACES PROVIDED THE R403.6.3 TESTING. MECHANICAL VENTILATION SYSTEMS SHALL BE TESTED AND VERIFIED TO PROVIDE THE MINIMUM VENTILATION FLOW RATES REQUIRED BY ?j 1. ADDITIONS TH T INCREASE THE BUILDING'S TOTAL CONDITIONED FLOOR AREA BY LESS THAN 25 PERCENT. ACCORDANCE WITH ANSI !ACCA MANUAL D BASED ON CALCULATIONS MADE IN ACCORDANCE WITH SECTION R FUN DUCT SYSTEMS SERVING MORE THAN SECTION R403.6, IN ACCORDANCE WITH ANSI/RESNET/ICC 380. WHERE REQUIRED BY THE BUILDING OFFICIAL, TESTING SHALL BE CONDUCTED BY AN W HATCH MEETS ALL OF THE FOLLOWING: TWO DWELLING UNITS OR; SLEEPING UNITS SHALL BE SIZED IN ACCORDANCE WITH THE ASHRAE HANDBOOK OF FUNDAMENTALS, ANSI/ACCA MANUAL D APPROVED THIRD PARTY. A WRITT N REPORT F TH T 2. ADDITIONS THAT DO NOT INCLUDI_ THE ADDITION OR REPUACEMENT OF EQUIPMENT COVERED IN SECTION R4D3.5 OR R403.7 2.1. THE AVERAGE U-FACTOR OF THE HATCH SHALL BE LESS THAN OR EQUAL TO U-0.10 OR HAVE AN AVERAGE INSULATION R-VALUE OF R-10 OR OR OTHER EQUIVALENT COMPUTATION PROCEDURE BASED ON CALCULATIONS MADE IN ACCORDANCE WITH SECTION R403.7. E 0 E RESUL S OF THE TEST SHALL BE SIGNED BY THE PARTY CONDUCTING THE TEST AND PROVIDED TO >y THE BUILDING OFFICIAL. 0L 3. ADDITIONS THAT DO NOT INCREA`.�E CONDITIONED SPACE GREATER. R403.3.2 BUILDING CAVITTIES. BUILDING FRAMING CAVITIES SHALL NOT BE USED AS DUCTWORK OR PLENUMS. 4. WHERE THE ADDITION ALONE OR THE EXISTING BUILDING A1ND ADDITION TOGETHER COMPLY WITH SECTION R405 OR R406. 2.2. NOT LESS THAN 75 PERCENT OF THE PANEL AREA SHALL HAVE AN INSULATION R-VALUE OF R-13 OR GREATER. EXCEPTIONS: O O a Q R403.3.3 DUCTWORK LOCATED OUTSIDE CONDITIONED SPACE. SUPPLY AND RETURN DUCTWORK LOCATED OUTSIDE CONDITIONED SPACE SHALL BE 1. KITCHEN RANGE HOODS THAT ARE DUCTED TO THE OUTSIDE WITH DUCTING HAVING A DIAMETER OF 6 INCHES (152 MM) OR LARGER, A LENGTH OF I- �- W Im SECTION R503 ALTERATIONS 2.3. THE NET AREA OF THE FRAMED OPENING SHALL BE LESS THAN OR EQUAL TO 13.5 SQUARE FEET (1.25 M2). INSULATED TO AN R-VALLUE OF NOT LESS THAN R-8 FOR DUCTS 3 INCHES (76 MM) IN DIAMETER AND LARGER AND NOT LESS THAN R-6 FOR DUCTS 10 FEET (3028 MM) OR LESS, AND NOT MORE THAN TWO 90-DEGREE (1.57 RAD) ELBOWS OR EQUIVALENT SHALL NOT REQUIRE TESTING. ff-^ !!-^ N R503.1 GENERAL. ALTERATIONS TO ANY BUILDING OR STRUCTURE SHALL COMPLY WITH THE REQUIREMENTS OF THE CODE FOR NEW CONSTRUCTION. 2.4. THE PERIMETER OF THE HATCH EDGE SHALL BE WEATHER-STRIPPED. SMALLER THAN 3 INCHESS (76 MM) IN DIAMETER. DUCTWORK BURIED BENEATH A BUILDING SHALL BE INSULATED AS REQUIRED PER THIS SECTION OR W v! fli LO ALTERATIONS SHALL BE SUCH THAT THE EXISTING BUILDING OR STRUCTURE IS NOT LESS CONFORMING TO THE PROVISIONS OF THIS CODE THAN THE HAVE AN EQUIVALENT THiERMAL DISTRIBUTION EFFICIENCY. UNDERGROUND DUCTWORK UTILIZING THE THERMAL DISTRIBUTION EFFICIENCY METHOD SHALL 2. A THIRD PARTY TEST SHALL NOT BE REQUIRED WHERE THE VENTILATION SYSTEM HAS AN INTEGRATED DIAGNOSTIC TOOL USED FOR AIRFLOW - Ln THE REDUCTION SHALL NOT APPLY TO THE COMPONENT PERFORMANCE ALTERNATIVE IN SECTION R402.1.5. MEASUREMENT, AND A USER INTERFACE THAT COMMUNICATES THE INSTALLED AIRFLOW RATE. CV CV IL (� EXISTING BUILDING OR STRUCTURE WAS PRIOR TO THE ALTERATION. ALTERATIONS SHALL NOT CREATE AN UNSAFE OR HAZARDOUS CONDITION OR R402.2.5.1 ACCESS HATCHES AND DOOR INSULATION INSTALLATION AND RETENTION. VERTICAL OR HORIZONTAL ACCESS HATCHES AND DOORS FROM BE LISTED AND LABELED TO INDICATE THE R-VALUE EQUIVALENCY. , OVERLOAD EXISTING BUILDING SYSTEMS. ALTERATIONS TO EXISTIPNG BUILDINGS SHALL COMPLY WITH SECTIONS R503.1.1 THROUGH R503.1.5. - P NT R403.3.4 DUCT SYSTEMS' LOCATED IN CONDITIONED SPACE. FOR DUCT SYSTEMS TO BE CONSIDERED INSIDE A CONDITIONED SPACE, THE SPACE 3. WHERE TESTED IN ACCORDANCE WITH SECTION R403.6.4, TESTING OF EACH MECHANICAL VENTILATION SYSTEM IS NOT REQUIRED. Q 0 Q (- CONDITIONED SPACES TO UNCONDITIONED SPACES SUCH AS ATTICS AND CRAWL SPACES SHALL BE WEATHER STRIPPED. ACCESS THAT REV' S I I TH RMAL ENVELOPE ASSEMBLIES SHALL COMPLY WITH THIS SECTION. _ CONDITIONING EQUIPMENT[ SHALL BE LOCATED COMPLETELY ON THE CONDITIONED SIDE OF THE BUILDING THERMAL ENVELOPE. THE DUCTWORK SHALL R403.6.5 INTERMITTENT EXHAUST CONTROL FOR BATHROOMS AND TOILET ROOMS. WHERE AN EXHAUST SYSTEM SERVING A BATHROOM OR TOILET ROOM IS Q [NY] R503.1.1 BUILDING THERMAL ENJVELOPE. ALTERATIONS OFF EXISTING BU LD NG E DAMAGING OR COMPRESSING THE INSULATION SHALL BE PROVIDED TO ALL EQUIPMENT. WHERE LOOSE-FILL INSULATION IS INSTALLED, A WOOD FRAMED W W W NEW BUILDING THERMAL ENVELOPE ASSEMBLIES THAT ARE PART- OF THE ALTERATION SHALL COMPLY WITH SECTION R402. THE R-VALUE OF INSULATION OR EQUIVALENT BAFFLE, RETAINER OR DAM SHALL BE INSTALLED TO PREVENT LOOSE-FILL INSULATION FROM SPILLING INTO LIVING SPACE FROM HIGHER COMPLY WITH THE FOLLOWING, AS APPLICABLE: DESIGNED FOR INTERMITTENT OPERATION, THE EXHAUST SYSTEM CONTROLS SHALL INCLUDE ONE OR MORE OF THE FOLLOWING: u�^^ W'^ SHALL NOT BE REDUCED, NOR THE U-FACTOR OF A BUILDING THERMAL ENVELOPE ASSEMBLY INCREASED AS PART OF A BUILDING THERMAL ENVELOPE TO LOWER SECTIONS OF THE ATTIC AND FROM ATTICS COVERING CONDITIONED SPACES TO UNCONDITIONED SPACES. THE BAFFLE OR RETAINER SHALL 1. THE DUCTWORK SHAALL BE LOCATED COMPLETELY ON THE CONDITIONED SIDE OF THE BUILDING THERMAL ENVELOPE. 1. A TIMER CONTROL WITH ONE OR MORE DELAY SEFPOINTS THAT AUTOMATICALLY TURNS OFF EXHAUST FANS WHEN THE SELECTED SETPOINT IS U) W vJ [_ ALTERATION EXCEPT WHERE THE BUILDING AFTER THE ALTERATION COMPLIES WITH SECTION R405 OR R406. PROVIDE A PERMANENT MEANS OF MAINTAINING THE INSTALLED R-VALUE OF THE LOOSE-FILL INSULATION. 2. DUCTWORK IN VENTHLATED ATTIC SPACES OR UNVENTED ATTICS WITH VAPOR DIFFUSION PORTS SHALL BE BURIED WITHIN CEILING INSULATION IN REACHED. NOT FEWER THAN ONE DELAY-OFF SETPOINT SHALL BE 30 MINUTES OR LESS. O O O � 1. STORM WINDOWS INSTALLED OVER EXISTING FENESTRATION.. R402.4 FENESTRATION. IN ADDITION TO THE REQUIREMENTS OF SECTION R402, FENESTRATION SHALL COMPLY WITH SECTIONS R402.4.1 THROUGH ACCORDANCE WITH !SECTION R403.3.5 AND SHALL COMPLY WITH THE FOLLOWING: 2. AN OCCUPANT SENSOR CONTROL WITH ONE OR MORE DELAY SETPOINTS THAT AUTOMATICALLY TURNS OFF EXHAUST FANS IN ACCORDANCE WITH THE � m � W R402.4.5. SELECTED DELAY SETPOINT AFTER ALL OCCUPANTS HAVE VACATED THE SPACE. NOT FEWER THAN ONE DELAY-OFF SETPOINT SHALL BE 30 (MINUTES 2. ROOF RE-COVER. 2.1. THE DUCTWORK I LEAKAGE, AS MEASURED EITHER BY A ROUGH-IN TEST OF THE SUPPLY AND RETURN DUCTWORK OR A POSTCONSTRUCTION O O O 0- 3. SURFACE-APPLIED WINDOW FILM INSTALLED ON EXISTING SINGLE PANE FENESTRATION ASSEMBLIES TO REDUCE SOLAR HEAT GAIN PROVIDED THAT R402.4.1 U-FACTOR. AN AREA-WEIGHTED AVERAGE OF FENESTRATION PRODUCTS SHALL BE PERMITTED TO SATISFY THE U-FACTOR REQUIREMENTS. DUCT SYSTEM LEEAKAGE TEST TO OUTSIDE THE BUILDING THERMAL ENVELOPE IN ACCORDANCE WITH SECTION R403.3.7, IS NOT GREATER THAN OR LESS. ��// �/ O THE CODE DOES NOT REQUIRE THE GLAZING OR FENESTRIATION ASSEMBLY TO BE REPLACED. R402.4.2 GLAZED FENESTRATION SHGC. AN AREA-WEIGHTED AVERAGE OF FENESTRATION PRODUCTS MORE THAN 50 PERCENT GLAZED SHALL BE 1.5 CUBIC FEET I PER MINUTE (42.5 L/MIN) PER 100 SQUARE FEET (9.29 M2) OF CONDITIONED FLOOR AREA SERVED BY THE DUCT SYSTEM. 3. A HUMIDITY CONTROL WITH AN ADJUSTABLE SETPOINT RANGING BETWEEN 50 PERCENT OR MORE AND 80 PERCENT OR LESS RELATIVE HUMIiDITY OL � W THAT AUTOMATICALLY TURNS OFF EXHAUST FANS WHEN THE SELECTED SETPOINT IS REACHED. 4. GLASS ONLY REPLACEMENTS IN AN EXISTING SASH AND FRAME. PERMITTED TO SATISFY THE SHGC REQUIREMENTS. DYNAMIC GLAZING SHALL BE PERMITTED TO SATISFY THE SHGC REQUIREMENTS OF TABLE R402.1.2 2.2. THE CEILING INSI;ULATION R-VALUE INSTALLED AGAINST AND ABOVE THE INSULATED DUCTWORK IS GREATER THAN OR EQUAL TO 7HE PROPOSED � a. � � I IN PROVIDED THAT THE RATIO OF THE HIGHER TO LOWER LABELED SHGC IS GREATER THAN OR EQUAL TO 2.4, AND THE DYNAMIC GLAZING IS CEILING INSULATITON R-VALUE, LESS THE R-VALUE OF THE INSULATION ON THE DUCTWORK. 4. A CONTAMINANT CONTROL THAT RESPONDS TO A PARTICLE OR GASEOUS CONCENTRATION AND AUTOMATICALLY TURNS OFF EXHAUST FANS WHEN A 5. AIR BARRIERS SHALL NOT BE REQUIRED FOR ROOF RECOWER AND ROOF REPLACEMENT WHERE THE ALTERATIONS OR RENOVATIONS TO THE BU LD G AUTOMATICALLY CONTROLLED TO MODULATE THE AMOUNT OF SOLAR GAIN INTO THE SPACE IN MULTIPLE STEPS. DYNAMIC GLAZING SHALL BE CONSIDERED DESIGN SETPOINT IS REACHED. DO NOT INCLUDE ALTERATIONS, RENOVATIONS, OR REPAIRS> TO THE REMAINDER OF THE BUILDING THERMAL ENVELOPE. 3. DUCTWORK CONTAINIJED WITHIN WALL OR FLOOR ASSEMBLIES SEPARATING UNCONDI110NED FROM CONDITIONED SPACE SHALL COMPLY WITH THE SEPARATELY FROM OTHER FENESTRATION, AND AREAWEIGHTED AVERAGING WITH OTHER FENESTRATION THAT IS NOT DYNAMIC GLAZING SHALL BE FOLLOWING: MANUAL OFF FUNCTIONALITY SHALL NOT BE USED IN LIEU OF THE MINIMUM SETPOINT FUNCTIONALITY REQUIRED BY THIS SECTION. Date: OZ�OZ�Z6 6. REPLACEMENT OF EXISTING DOOF'S THAT SEPARATE CONDIITIONED SPACE FROM THE EXTERIOR SHALL NOT REQUIRE THE INSTALLATION OF A PROHIBITED. R F H I M EXCEPTION: BATHROOM AND TOILET ROOM EXHAUST SYSTEMS SERVING AS AN INTEGRAL COMPONENT OF AN OUTDOOR AIR VENTILATION SYSTEM OIR A R VESTIBULE OR REVOLVING DOOR, PROVIDED, HOWEVER, THAT AN EXISTING VESTIBULE THAT SEPARATES SUCH CONDITIONED SPACE FROM THE EXCEPTION: DYNAMIC GLAZING SHALL NOT BE REQUIRED TO COMPLY WITH THIS SECTION WHERE BOTH THE LOWER AND HIGHER LABELED SHGC COMPLY 3.1. A CONTINUOUS /AIR BARRIER SHALL BE INSTALLED AS PAT 0 T E BU LDNG ASS' BLY BETWEEN THE DUCTWORK AND THE UNCONDITIONED EXCEPTI HOUSE MECHANICAL VENTILATION SYSTEM. EXTERIOR SHALL NOT BE REMOVI=D. WITH THE REQUIREMENTS OF TABLE R402.1.2. SPACE. Scale: NOTED R503.1.1.1 FENESTRATION ALTERATION`S. WHERE NEW FENESTRATION IS ADDED TO AN EXISTING BUILDING, THE NEW FENESTRATION SHALL COMPLY WITH 3.2. DUCTWORK SHAL'_L BE INSTALLED IN ACCORDANCE WITH SECTION R403.3.3. SECTION R402.4. WHERE SOME OR AL.L OF AN EXISTING FENESTRATION UNIT IS REPLACED WITH A NEW FENESTRATION PRODUCT, INCLUDING SASH AND R402.4.3 GLAZED FENESTRATION EXEMPTION. NOT GREATER THAN 15 SQUARE FEET (1.4 M2) OF GLAZED FENESTRATION PER DWELLING UNIT SHALL BE EXCEPTION: WHEERE THE BUILDING ASSEMBLY CAVITIES CONTAINING DUCTWORK HAVE BEEN AIR SEALED IN ACCORDANCE WITH SECTION Drawn: GLAZING, THE REPLACEMENT FENESTRATION SHALL MEET THE AIPPLICABLE REQUIREMENTS FOR U-FACTOR AND SOLAR HEAT GAIN COEFFICIENT (SHGC) AS EXEMPT FROM THE U FACTOR AND SHGC REQUIREMENTS IN SECTION R402.1.2. THIS EXEMPTION SHALL NOT APPLY TO THE COMPONENT PERFORMANCE BAJ SPECIFIED IN TABLE R402.1.3. WHERE MORE THAN ONE REPLACEMENT FENESTRATION UNIT IS TO BE INSTALLED, AN AREA-WEIGHTED AVERAGE OF THE ALTERNATIVE IN SECTION R402.1.5. R402.5.1 AND INSULATED) IN ACCORDANCE WITH ITEM ES DUCT INSULATION IS NOT REQUIRED. 3.3. NOT LESS THAN R-10 INSULATION, OR NOT LESS THAN 50 PERCENT OF THE REQUIRED INSULATION R-VALUE SPECIFIED IN TABLE R402.1.3, U-FACTOR, SHGC, OR BOTH OF ALL REPLACEMENT FENESTRATION UNITS SHALL BE AN ALTERNATIVE THAT CAN BE USED TO SHOW COMPLIANCE. R402.4.4 OPAQUE DOOR EXEMPTION. ONE SIDE-HINGED OPAQUE DOOR ASSEMBLY NOT GREATER THAN 24 SQUARE FEET (2.22 M2) IN AREA SHALL BE WHICHEVER IS GBREATER, SHALL BE LOCATED BETWEEN THE DUCTWORK AND THE UNCONDITIONED SPACE. Job: [NY] R503.1.1.2 ROOF. CEILING, AN[) ATTIC ALTERATIONS. WHERE REPLACEMENT OF CEILING FINISHES EXPOSES CAVITIES OF THE ROOF-CEILING EXEMPT FROM THE U-FACTOR REQUIREMENT IN SECTION R402.1.2. THIS EXEMPTION SHALL NOT APPLY TO THE COMPONENT PERFORMANCE ALTERNATIVE IN SECTION R402.1.5. 3.4. SEGMENTS OF DUUCTWORK CONTAINED WITHIN THESE BUILDING ASSEMBLIES SHALL NOT BE CONSIDERED COMPLETELY INSIDE CONDITIONED SPACE CONSTRUCTION, THAT IS PART OF THE BUILDING THERMAL ENVELOPE, THE CAVITIES SHALL BE INSULATED TO FULL DEPTH WITH NEW OR EXISTING Sheet INSULATION THAT COMPLIES WITH SECTION R303.1.4. AND HAVINJG A MINIMUM NOMINAL VALUE OF R-3 PER INCH. INSULATION SHALL COMPLY WITH [NY] R402.4.5 SUNROOM AND HEATED GARAGE FENESTRATION. SUNROOMS AND HEATED GARAGES ENCLOSING CONDITIONED SPACE SHALL COMPLY WITH FOR COMPLIANCE' WITH SECTION R405 IN R406. �/(� SECTION R402.1 FOR NEW CAVITIES CREATED AND THE FOLLOWING ALTERATIONS: THE FENESTRATION REQUIREMENTS OF THIS CODE. [NY] RINSUL 5 ON, SU FRK BURIED WITHIN CEILING INSULATION. WHERE SUPPLY AND RETURN DUCTWORK IS PARTIALLY OR COMPLETELY BURIED IN A �(� 4 1. AN ALTERATION TO ROOF/CEILING; CONSTRUCTION OTHER THAN REROOFING WHERE EXISTING INSULATION LOCATED BELOW THE ROOF DECK OR AN EXCEPTION: FOR SUNROOMS AND HEATED GARAGES WITH THERMAL ISOLATION AND ENCLOSING CONDITIONED SPACE, THE FENESTRATION U-FACTOR SHALL CEILING INSULATION), SUCCH DUCTWORK SHALL COMPLY WITH THE FOLLOWING: LLLL���� l!! of - Sheets - I i Receive(i OCT 21 2026 REVISION BY TABLE R403.6.2 FAN EFFICACY FOR WHOLE-HOUSE MECHANICAL VENTILATION SYSTEMS AND OUTDOOR AIR VENTILATION SYSTEMS Zoning Board of Appeals TABLE R403.6.2 - FAN EFFICACY FOR WHOLE HOUSE MECHANICAL VENTH ATIO14 SYSTEMS AND OUTDOOR VENTILATION SYSTEMSa TABLE R402.5.1.1 AIR BARRIER, AIR SEALING AND INSULATION INSTALL ATIONa SYSTEM TYPE AIRFLOW RATE (ICFM) MINIMUM EFFICACY TEST PROCEDURE (CFI/WATT) COMPONENT AIR BARRIER, AIR INSULATION HRV OR ERV ANY 1.20 CAN/CSA C439 SEALING CRITERIA INSTALLATION CRITERIA I... p BALANCED VENTILATION A CONTINUOUS AIR BARRIER SHALL BE INSTALLED IN THE AIR-PERMEABLE INSULATION SHALL NOT BE USED AS A SYSTEM WITHOUT HEAT ANY 1.2° - A H 1 GENERAL REQUIREMENTS BUILDING THERMAL ENVELOPE. BREAKS OR JOINTS IN THE AIR SEALING MATERIAL. W ANSI/AMCA 210 ANSI/ S RA E 5 BARRIER SHALL BE SEALED. OR ENERGY RECOVERY W 0 00 AN AIR BARRIER SHALL BE INSTALLED IN ANY DROPPED CEILING THE INSULATION IN ANY DROPPED CEILING/SOFFIT SHALL BE J Z m C9 RANGE HOOD ANY 2.8 OR SOFFIT TO SEPARATE IT FROM UNCONDITIONED SPACE. ALIGNED WITH THE AIR BARRIER. ACCESS HATCHES AND O w LO ACCESS OPENINGS, DROP DOWN STAIRS OR KNEE WALL DOORS DOORS S HALL BE INSTALLED AND INSULATED IN ACCORDANCE _z = J F- CEILING/ATTIC O .� O co IN-LINE SUPPLY OR TO UNCONDITIONED ATTIC SPACES SHALL BE SEALED WITH WITH SECTION R402.2.5. Q Q - cn EXHAUST FAN ANY 3.8 GASKETING MATERIALS THAT ALLOW FOR REPEATED ENTRANCE EAVE BAFFLES SHALL BE INSTALLED IN ACCORDANCE WITH l- O OVER TIME. SECTION R402.2.4. mw < 90 2.8 ANSI/AMCA 210-ANSI/ASHRAE 51 Q M CAVITIES WITHIN CORNERS AND HEADERS OF FRAME WALLS U � OTHER EXHAUST FAN THE JUNCTION OF THE FOUNDATION AND SILL PLATE SHALL BE SHALL BE INSULATED BY COMPLETELY FILLING THE CAVITY z 90 OR < 200 3.5 SEALED. WALLS WITH A MATERIAL HAVING A THERMAL RESISTANCE, R-VALUE, >_ 200 4.0 THE JUNCTION OF THE TOP PLATE AND THE TOP OF EXTERIOR OF NOT [LESS THAN R-3 PER INCH. EXTERIOR BUILDING WALLS SHALL BE SEALED. THERMAL ENVELOPE INSULATION FOR FRAMED WALLS SHALL KNEE WALLS SHALL BE SEALED. BE INSTAILLED IN SUBSTANTIAL CONTACT AND CONTINUOUS OUTDOOR AIRFLOW AS SPECIFIED. ALIGNMENT WITH THE AIR BARRIER. AIR-HANDLING UNIT FAN POWER AIR HANDLING UNIT DETERMINED IN ACCORDANCE WITH INSULATIO)N INSTALLED IN A KNEE WALL ASSEMBLY SHALL BE THAT IS INTEGRATED ANY 1.2 THE APPLICABLE US DEPARTMENT KNEE WALLS SHALL HAVE AN AIR BARRIER BETWEEN CONDITIONED INSTALLED IN ACCORDANCE WITH SECTION R402.2.3. �A TO TESTED AND LISTED OF ENERGY CODE OF FEDERAL KNEE WALL AND UNCONDITIONED SPACE AIR-PERMEABLE INSULATION SHALL BE ENCLOSED INSIDE HVAC EQUIPMENT REGULATIONS DOE10 CFR430 OR AN AIR BARRIER ASSEMBLY. OTHER APPROVED TEST METHOD THE ROUGH OPENING GAP BETWEEN FRAMING AND THE INSULATION SHALL NOT BE REQUIRED IN THE ROUGH OPENING �! WINDOWS, SKYLIGHTS FRAMES OF SKYLIGHTS, WINDOWS AND DOORS, SHALL BE For SI: 1 cubic foot per minute 28.3 L/min. AND DOORS SEALED IN ACCORDANCE WITH FENESTRATION MANUFACTURER'S GAP EXCEPT AS REQUIRED BY THE FENESTRATION a. For balanced ventilation systems, HRVs and ERVs, determine the efficacy as the outdoor INSTRUCTIONS. MANUFACTFURER'S INSTRUCTIONS. airflow divided by the total fan power. RIM JOISTS SHALL INCLUDE AN AIR BARRIER. RIM JOISTFS SHALL BE INSULATED SO THAT THE INSULATION R403.7 EQUIPMENT SIZING AND EFFICIENCY RATING. HEATING AIND COOLING EQUIPMENT SHALL BE SIZED IN ACCORDANCE WITH ACCA MANUAL S RIM JOISTS THE JUNCTIONS OF THE RIM BOARD TO THE SILL PLATE AND MAINTAINS PERMANENT CONTACT WITH THE EXTERIOR RIM BASED ON BUILDING LOADS CALCULATED IN ACCORDANCE WITHI ACCA MANUAL J OR OTHER APPROVED HEATING AND COOLING CALCULATION THE RIM BOARD AND THE SUBFLOOR SHALL BE AIR SEALED. BOARD' METHODOLOGIES. NEW OR REPLACEMENT HEATING AND COOLINGS EQUIPMENT SHALL HAVE AN EFFICIENCY RATING EQUAL TO OR GREATER THAN FLOOR FRAMING MEMBERS THAT ARE PART OF THE BUILDING THE MINIMUM REQUIRED BY FEDERAL LAW FOR THE GEOGRAPHIC LOCATION WHERE THE EQUIPMENT IS INSTALLED. FLOORS, INCLUDING THERMAL ENVELOPE SHALL BE AIR SEALED TO MAINTAIN A [NY] R403.7.1 ELECTRIC-RESISTANCE SPACE HEATING. DWELLLING UNITS, SLEEPING UNITS, AND OTHER OCCUPIABLE SPACES WITHIN THE BUILDING CANTILEVERED FLOORS AND FLOOR INISULATION SHALL BE INSTALLED IN ACCORDANCE CONTINUOUS AIR BARRIER. r �F USING ELECTRIC-RESISTANCE SPACE HEATING SHALL LIMIT THE: TOTAL INSTALLED HEATING CAPACITY OF ALL ELECTRIC-RESISTANCE SPACE HEATING WITH THE REQUIREMENTS OF SECTION R402.2.8. SERVING THE DWELLING UNIT TO NOT MORE THAN 2.0 KW OR SHALL INSTALL A HEAT PUMP IN THE LARGEST SPACE THAT IS NOT USED AS A FLOORS ABOVE GARAGES AIR PERMEABLE FLOOR CAVITY INSULATION SHALL BE BEDROOM. ENCLOSED. T SERVING MULTIPLE DWELLING UNITS. EXCEPT FOR SYSTEMS COMPLYING WITH SECTION R403.9 SYSTEMS SERVING MULTIPLE + M R403.8 SYSTEMS SE EXPOSED EARTH IN CRAWL SPACES SHALL BE COVERED WITH DWELLING UNITS SHALL COMPLY WITH SECTIONS C403 AND C4E04 OF THE ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK CRAWL SPPACE INSULATION, WHERE PROVIDED INSTEAD OF STATE-COMMERCIAL PROVISIONS INSTEAD OF SECTION R403. A CLASS I VAPOR RETARDER/AIR BARRIER IN ACCORDANCE FLOOR INISULATION, SHALL BE INSTALLED IN ACCORDANCE EXCEPTION: SYSTEMS COMPLYING WITH SECTION R403.9. WITH SECTION R402.2.11. WITH SECTION R402.2.11. PENETRATIONS THROUGH CONCRETE FOUNDATION WALLS CONDITIONED BASEMENT FOUNDATION WALL INSULATION BASEMENT, CRAWL SPACE SECTION R404 ELECTRICAL POWER, LIGHTING AND RENEWABLE ENERGY SYSTEMS AND SLAB FOUNDATIONS AND SLABS SHALL BE AIR SEALED. SHALL BE INSTALLED IN ACCORDANCE WITH SECTION R404.1 LIGHTING EQUIPMENT. ALL PERMANENTLY INSTALLED LUJMINAIRES SHALL BE CAPABLE OF OPERATION WITH AN EFFICACY OF NOT LESS CLASS 1 VAPOR RETARDERS SHALL NOT BE USED AS AN AIR R402.2.9.1. -THAN 45 LUMENS PER WATT OR SHALL CONTAIN LAMPS CAPAVBLE OF OPERATION WITH AN EFFICACY OF NOT LESS THAN 65 LUMENS PER WATT. BARRIER ON BELOW-GRADE WALLS AND SHALL BE INSTALLED SLAB-ONI-GRADE FLOOR INSULATION SHALL BE INSTALLED IN EXCEPTIONS: IN ACCORDANCE WITH SECTION R702.7 OF THE RESIDENTIAL ACCORDANCE WITH SECTION R402.2.10.CODE OF NEW YORK STATE. (D 1. APPLIANCE LAMPS. 2. ANTIMICROBIAL LIGHTING USED FOR THE SOLE PURPOSE OF DISINFECTING. DUCT AND FLUE SHAFTS TO EXTERIOR OR UNCONDITIONED -� E 3. GENERAL SERVICE LAMPS CONPLYING WITH DOE 10 CFRt, PART 430.32. SPACE SHALL BE SEALED. INSULATIO)N SHALL BE FITTED TIGHTLY AROUND UTILITIES U O CD CY) UTILITY PENETRATIONS OF THE AIR BARRIER SHALL BE PASSING THROUGH SHAFTS AND PENETRATIONS IN THE V 4. LUMINAIRES WITH A RATED ELECTRIC INPUT OF NOT GREATER THAN 3.0 WATTS. SHAFTS, PENETRATIONS CAULKED, GASKETED OR OTHERWISE SEALED AND SHALL BUILDING THERMAL ENVELOPE TO MAINTAIN REQUIRED _C N ti a)d' L R404.1.1 EXTERIOR LIGHTING. CONNECTED EXTERIOR LIGHTING FOR GROUP R-2, R-3 AND R-4 RESIDENTIAL BUILDINGS SHALL COMPLY WITH ALLOW FOR EXPANSION, CONTRACTION OF MATERIALS AND R-VALUE.. Q (n N U SECTIONS R404.1.2 THROUGH R404.1.5. EXCEPTIONS: MECHANICAL VIBRATION. � � � � � �c Z ti z 1. DETACHED ONE- AND TWO- FAMILY DWELLINGS. BATTS TO) BE INSTALLED IN NARROW CAVITIES SHALL BE CUT > LO L 2. TOWNHOUSES. NARROW CAVITIES OF 1 INCH OR LESS THAT ARE NOT ABLE TO TO FIT OIR NARROW CAVITIES SHALL BE FILLED WITH NARROW CAVITIES O THE AVAILLABLE CAVITY SPACE. +- O � 3. GROUP R-3 BUILDINGS THAT DO NOT CONTAIN MORE TFHAN TWO DWELLING UNITS. BE INSULATED SHALL BE AIR SEALED. INSULATIO)N THAT ON INSTALLATION READILY CONFORMS TO �_ C -0 `- (U O 4. SOLAR-POWERED LAMPS NOT CONNECTED TO ANY ELECTRICAL SERVICE. J W 5. LUMINAIRES CONTROLLED BY A MOTION SENSOR. INSULATED PORTIONS OF THE GARAGE SEPARATION ASSEMBLY 6. LAMPS AND LUMINAIRES THAT COMPLY WITH SECTION R2404.1. GARAGE SEPARATION AIR SEALING SHALL BE PROVIDED BETWEEN THE GARAGE N LO � ~ AND CONDITIONED SPACES. SHALL BE INSTALLED IN ACCORDANCE WITH SECTIONS _ R404.1.2 EXTERIOR LIGHTING POWER REQUIREMENTS. THE TOTAL EXTERIOR CONNECTED LIGHTING POWER SHALL BE NOT GREATER THAN THE R303 AND R402.2.8. "a EXTERIOR LIGHTING POWER ALLOWANCE CALCULATED IN ACCORDANCE WITH SECTION R404.1.3. THE TOTAL EXTERIOR CONNECTED LIGHTING POWER RECESSED LIGHT FIXTURES INSTALLED IN THE BUILDING THERMAL RECESSED LIGHT FIXTURES INSTALLED IN THE BUILDING SHALL BE THE TOTAL MAXIMUM RATED WATTAGE OF ALL LIGHITING THAT IS POWERED THROUGH THE ENERGY SERVICE FOR THE BUILDING. Q EXCEPTIONS: LIGHTING USED FOR THE FOLLOWING APPLICATIONS SHALL NOT BE INCLUDED. RECESSED LIGHTING ENVELOPE SHALL BE AIR SEALED IN ACCORDANCE WITH THERMAL ENVELOPE SHALL BE AIRTIGHT AND IC RATED, AND SECTION R402.5.4. SHALL BE BURIED IN OR SURROUNDED WITH INSULATION. 1. LIGHTING APPROVED FOR SAFETY REASONS. 2. EMERGENCY LIGHTING THAT IS AUTOMATICALLY OFF DURING NORMAL OPERATIONS. INSULATION SHALL BE INSTALLED TO FILL THE AVAILABLE ALL HOLES CREATED BY WIRING, PLUMBING OR OTHER SPACE AND SURROUND WIRING, PLUMBING, OR OTHER 3. EXIT SIGNS. PLUMBING, WIRING OR OBSTRUCTIONS IN THE AIR BARRIER ASSEMBLY SHALL BE AIR OBSTRUCITIONS, UNLESS THE REQUIRED R-VALUE CAN BE O 4. SPECIALIZED SIGNAL, DIRECTIONAL AND MARKER LIGHTING ASSOCIATED NTH TRANSPORTATION. OTHER OBSTRUCTIONS SEALED. MET BY INSTALLING INSULATION AND AIR BARRIER SYSTEMS 5. LIGHTING FOR ATHLETIC PLAYING AREAS. COMPLETEELY TO THE EXTERIOR SIDE OF THE OBSTRUCTIONS. 6. TEMPORARY LIGHTING. z 0) 7. LIGHTING USED TO HIGHLIGHT FEATURES OF ART, PUBLIIC MONUMENTS AND THE NATIONAL FLAG. SHOWERS, TUBS AND AN AIR BARRIER SHALL SEPARATE INSULATION IN THE BUILDING M FIREPLACES ADJACENT TO THERMAL ENVELOPE FROM THE SHOWER, TUB OR EXTERIOR' FRAMED WALLS ADJACENT TO SHOWERS, TUBS AND d� 8. LIGHTING FOR WATER FEATURES AND SWIMMING POOLS. THE BUILDING THERMAL FIREPLACE ASSEMBLIES. FIREPLACEES SHALL BE INSULATED. r 9. LIGHTING CONTROLLED FROM WITHIN SLEEPING UNITS ANVD DWELLING UNITS. ENVELOPE 10. LIGHTING OF THE EXTERIOR MEANS OF EGRESS AS REOWIRED BY THE BUILDING CODE OF NEW YORK STATE. U) R404.1.3 EXTERIOR LIGHTING POWER ALLOWANCE. THE TOTAL AREA OR LENGTH OF EACH AREA TYPE MULTIPLIED BY THE VALUE FOR THE AREA BOXES, HOUSING AND ENCLOSURES THAT PENETRATE THE W z TYPE IN TABLE R404.1 SHALL BE THE LIGHTING POWER (WATT(S) ALLOWED FOR EACH AREA TYPE. FOR AREA TYPES NOT LISTED, THE AREA ELECTRICAL, COMMUNICATION AIR BARRIER SHALL BE CAULKED, TAPED, ELEMENT TED OR TYPE THAT MOST CLOSELY REPRESENTS THE PROPOSED USE iOF THE AREA SHALL BE SELECTED. THE TOTAL EXTERIOR LIGHTING POWER AND OTHER EQUIPMENT OTHERWISE SEALED TO THE AIR BARRIER ELEMENT BEING BOXES, IDED HOUSING AND ENCLOSURES SHALL BE BURIED IN OR z ALLOWANCE (WATTS) SHALL BE THE SUM OF THE BASE SITE ALLOWANCE PLUS THE WATTS FROM EACH AREA TYPE. BOXES, HOUSINGS PENETRATED. ALL CONCEALED OPENINGS INTO THE BOX, HOUSING SURROUNJDED BY INSULATION. R404.1.4 ADDITIONAL EXTERIOR LIGH'ING POWER. ADDITIONAL (EXTERIOR LIGHTING POWER ALLOWANCES SHALL BE AVAILABLE FOR THE BUILDING AND ENCLOSURES OR ENCLOSURE SHALL BE SEALED. ALTERNATIVELY, AIR-SEALED W � BOXES SHALL BE INSTALLED IN ACCORDANCE WITH SECTION FACADES AT 0.075 W/FT2 (0.807 W/M2) OF GROSS ABOVE-(GRADE WALL AREA. THESE ADDITIONAL POWER ALLOWANCES SHALL BE USED ONLY R402.5.5. Q FOR THE LUMINAIRES SERVING THE FACADE AND SHALL NOT [BE USED TO INCREASE ANY OTHER LIGHTING POWER ALLOWANCE. 2 R404.1.5 GAS LIGHTING. GAS-FIRED LIGHTING APPLIANCES SHAALL NOT BE EQUIPPED WITH A CONTINUOUS PILOT AND SHALL BE EQUIPPED WITH HVAC SUPPLY AND RETURN REGISTER BOOTS SHALL BE HVAC SUPPLY AND RETURN REGISTER BOOTS LOCATED z I-_ AN ON-DEMAND PILOT, INTERMITTENT IGNITION OR INTERRUPTED IGNITION AS DEFINED BY ANSI Z21.20. HVAC REGISTER BOOTS SEALED TO THE SUBFLOOR, WALL COVERING OR CEILING WITHIN A BUILDING THERMAL ENVELOPE ASSEMBLY SHALL R404.2 INTERIOR LIGHTING CONTROLS_ ALL PERMANENTLY INSIALLED LUMINAIRES SHALL BE CONTROLLED AS REQUIRED IN SECTIONS R404.2.1 PENETRATED BY THE BOOT. BE BURIED IN OR SURROUNDED BY INSULATION. O O Q AND R404.2.2. WHERE REQUIRED TO BE SEALED, CONCEALED FIRE SPRINKLERS W EXCEPTION: LIGHTING CONTROLS SHALL NOT BE REQUIRED FOR SAFETY OR SECURITY LIGHTING. SHALL ONLY BE SEALED IN A MANNER THAT IS R404.2.1 HABITABLE SPACES. ALL PERMANENTLY INSTALLED LUMINAIRES IN HABITABLE SPACES SHALL BE CONTROLLED WITH A MANUAL DIMMER RECOMMENDED BY THE MANUFACTURER. CAULKING OR OR WITH AN AUTOMATIC SHUTOFF CONTROL THAT AUTOMATICALLY TURNS OFF LIGHTS WITHIN 20 MINUTES AFTER ALL OCCUPANTS HAVE LEFT CONCEALED SPRINKLERS Q Q OTHER ADHESIVE SEALANTS SHALL NOT BE USED TO FILL THE SPACE AND SHALL INCORPORATE A MANUAL CONTROL TO ALLOW OCCUPANTS TO TURN THE LIGHTS ON OR OFF. Q m VOIDS BETWEEN FIRE SPRINKLER COVER PLATES AND WALLS R404.2.2 SPECIFIC LOCATIONS. ALL PERMANENTLY INSTALLED LUMINAIRES IN GARAGES, UNFINISHED BASEMENTS, LAUNDRY ROOMS AND UTILITY OR CEILINGS. W ROOMS SHALL BE CONTROLLED BY AN AUTOMATIC SHUTOFF CONTROL THAT AUTOMATICALLY TURNS OFF LIGHTS WITHIN 20 MINUTES AFTER ALL OCCUPANTS HAVE LEFT THE SPACE AND SHALL INCORPORATE: A MANUAL CONTROL TO ALLOW OCCUPANTS TO TURN THE LIGHTS ON OR OFF. AN INTERIOR AIR BARRIER SHALL BE PROVIDED. AIR SEALING L.L.. J R404.3 EXTERIOR LIGHTING CONTROLS. EXTERIOR LIGHTING CONTROLS SHALL COMPLY WITH SECTION R404.3.1. AT THE INTERSECTIONS WITH BUILDING THERMAL ENVELOPE R404.3.1 CONTROLS FOR INDIVIDUAL DWELLING UNITS. WHERE THE TOTAL PERMANENTLY INSTALLED EXTERIOR LIGHTING POWER IS GREATER THAN SHALL BE PROVIDED. WHERE INSTALLED IN A O O Q 30 WATTS, THE PERMANENTLY INSTALLED EXTERIOR LIGHTING SHALL COMPLY WITH THE FOLLOWING: COMMON WALLS OR DOUBLE FIRE-RESISTANCE-RATED WALL ASSEMBLY, AIR SEALING MATERIALS INSULATION MATERIALS RECOGNIZED IN THE APPROVED I- I- W m �/ 1. LIGHTING SHALL BE CONTROLLED BY A MANUAL ON ANID OFF SWITCH WHICH PERMITS AUTOMATIC SHUTOFF ACTIONS. WALLS SEPARATING SHALL COMPLY WITH ONE OF THE FOLLOWING: COMMON WALL OR DOUBLE-WALL DESIGN AND INSTALLED IN Ln 2. LIGHTING SHALL BE AUTOMATICALLY SHUT OFF WHEN DAYLIGHT IS PRESENT AND SATISFIES THE LIGHTING NEEDS. ATTACHED SINGLE-FAMILY 1. BE IN ACCORDANCE WITH AN APPROVED DESIGN FOR THE ACCORDANCE WITH THE APPROVED DESIGN SHALL BE LO 3. CONTROLS THAT OVERRIDE AUTOMATIC SHUTOFF ACTIONS SHALL NOT BE ALLOWED UNLESS THE OVERRIDE AUTOMATICALLY RETURNS DWELLINGS OR TOWNHOUSES FIRE-RESISTANCE-RATED ASSEMBLY. PERMITTED TO BE USED. CV CV Ll- c'? AUTOMATIC CONTROL TO ITS NORMAL. OPERATION WITHIN 24 HOURS, 2. BE SUPPORTED BY APPROVED DATA THAT SHOWS THE Q Q Q I- [NY] R404.4 RENEWABLE ENERGY CERTIFICATE (REC) DOCUMENTATION. WHERE RENEWABLE ENERGY GENERATION IS USED TO COMPLY WITH THIS ASSEMBLY AS INSTALLED COMPLIES WITH THE REQUIRED CODE, A SIGNED ATTESTATION SHALL BE PROVIDED TO THE BUILDING OFFICIAL BY THE PROPERTY OWNER OR OWNERS AUTHORIZED AGENT FIRE-RESISTANCE RATING. W rr v!0/^�1 LU) DEMONSTRATING THAT WHERE RENEWABLE ENERGY CERTIFICATES (RECS) OR ENERGY ATTRIBUTABLE CERTIFICATES (EACS) ARE ASSOCIATED WITH a. Inspection of log walls shall be in accordance with the provisions of ICC400. THAT PORTION OF RENEWABLE ENERGY USED TO COMPLY WITH THIS CODE, THE OWNER HAS ENTERED INTO A REC OR EAC AGREEMENT THAT b. insulation full enclosure is not required in unconditioned/ventilated attic spaces and at rim joists. O O O COMPLIES WITH THE APPLICABLE PROVISIONS OF THIS CODE, INCLUDING THAT THE RECS OR EACS SHALL BE RETAINED, OR RETIRED, ON BEHALF D_ W D_ W OF THE PROPERTY OWNER. O 0 NO [NY] R404.5 DWELLING ELECTRICAL METER. EACH DWELLING (UNIT LOCATED IN A GROUP R-2 BUILDING SHALL HAVE A SEPARATE ELECTRICAL L.L L1. O METER OR SUBMETER. W W W W 0- Date: 02/02/26 Scale: NOTED Drawn: BAJ Job: Sheet A15 of - Sheets Received FRAMING NOTES: CONCRETE NOTES: NOTICE OF UTILIZATION OF TABLE R301.5 OCT 2 Y z 26 REVISION BY PRE-ENGINEERED WOOD CONSTRUCTION MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS 1. ALL DIMENSIONAL FRAMING LUMBER SHALL BE DOUGLAS FIR LARCH NO. 2 (OR SELECT 1. ALL CONCRETE TO BE CONTROLLED STONE CONCRETE HAVING A MINIMUM (in pounds per square foot) zoning Board o fPp als FASTENIrAG SCHED1ULE(R602.3(1)) STRUCTURAL GRADE OR BETTER) WITH MINIMUM ALLOWABLE BENDING STRESS OF 900 COMPRESSIVE STRENGTH OF 3,500 PSI @ 28 DAYS. (ACI 318 & 301). PLEASE TAKE NOTICE THAT THE CONSTRUCTION OF THIS RESIDENTIAL (PER 2020 RESIDENTIAL CODE NEW YORK STATE) Fb FOR REPETITIVE USE AND AN E OF 1,600,000 AS PER WESTERN WOOD PRODUCTS STRUCTURE TO BE CONSTRUCTED IN ACCORDANCE WITH THESE DOCUMENTS WILL UTILIZE PRE-ENGINEERED WOOD CONSTRUCTION FOR FLOOR AND UNIFORM LOAD CONCENTRATED ASSOCIATION SPAN TABLES. NUMBER OF NAIL SPACING 2. CAST-IN-PLACE CONCRETE SLABS SHALL BE REINFORCED W/ 1 LAYER OIF /DR USE (psf) LOAD (psf) JOINT DESCRIPTION COMMON NAILS 2. ALL PRE-ENGINEERED FRAMING LUMBER SHALL BE TJI SERIES WOOD I-BEAMS, 6x6-6/6 WWM (AS A MINIMUM IF NOT INDICATED OTHERWISE ON THE DRAWINGS) FRAMING. MICROLLAM LVL OR PARALLAM PSL (AS SPECIFIED ON THE DRAWINGS) AS W/ 6 MIL POLYETHYLENE VAPOR BARRIER OVER 6" COMPACTED FILL. INSTALL UNINHABITABLE ATTICS WITHOUT STORAGE 10 - R O O F FRAM I N Ca MICROLLAM MANUFACTURED BY WEYERHAUSER OR APPROVED EQUAL WITH THE FOLLOWING DESIGN CHAIRS AS REQUIRED. TO MAINTAIN CORRECT MESH PLACEMENT PRIOR TO POURING . THE OWNER SHALL: NOTIFY THE AUTHORITY HAVING JURISDICTION IN WRITING WITH THE APPLICATION FOR BUILDING PERMIT. UNINHABITABLE ATTICS WITH LIMITED STORAGE-9 20 1. BLOCKING BETWEEN CEILING JOISTS OR RAFTERS TO PROPERTIES: CONCRETE. - TOP PLATE 3-8d TOE NAIL 6 HABITABLE ATTICS AND ATTICS SERVED WITH FIXED STAIRS 30 - 3_ MICROLLAM BEAM: Fb=2,600psi E= 2.Ox10 e 3. ALL FOUNDATION ANCHOR BOLTS SHALL BE SIZED AS INDICATED ON DRAWINGS. 2. THE CONTRACTOR SHALL: PROVIDE AND INSTALL A SIGN NOTING PARALLAM BEAM: Fb=2,900psi E= 2.Ox10 ANY DEVIATION FROM THAT WHICH IS INDICATED ON THE DRAWINGS SHALL, NOT BE THE FOLLOWING PROVISIONS, WHICH SHALL CONFORM TO THE �_ 2. CEILING JOIST TO TOP PLATE 3-8d PER JOIST, TOE NAILPERMITTED. ANCHOR BOLTS SHALL BE EMBEDDED 8" MIN. FORMAT REQUIRED BY EXECUTIVE LAW 382-b. THE SIGN SHALL BALCONIES (EXTERIOR) AND DECKSe 40 - Q 4. ALL JOISTS, GIRDERS AND HEADERS SHALL HAVE BEARING STIFFENERS INSTALLED AS BE LOCATED AS DICTATED BY THE LOCAL PERMITTING AUTHORITY. O FIRE ESCAPES 40 - ao 3. CEILING JOIST NOT ATTACHED TO PARALLEL RAFTER, LAPS 3-16d FACE NAIL PER THE MANUFACTURER'S RECOMMENDATIONS. WEB STIFFENERS SHALL BE 4. ALL CONCRETE WORK SHALL CONFORM TO ALL THE REQUIREMENTS OF A.C.I. 301-10, W m ``' OVER PARTITIONS [SEE SECTIONS 'R802.3.1 R802.3.2 AND REQUIRED AT ALL LOAD AND LOAD BEARING POINTS AT A MINIMUM. A SINGLE 1 00 (1) THE SIGN OR SYMBOL SHALL CONSIST OF A CIRCLE SIX INCHES GUARDS - 200E JO } coo 3/4" LVL RIM JOIST SHALL BE REQUIRED AT FLOOR PERIMETERS. HANDLING, "SPECIFICATIONS FOR STRUCTURAL CONCRETE IN BUILDINGS". (152.4 MM IN DIAMETER, WITH A STROKE WIDTH OF 1 2 INCH 12.7 0- -� Z CO M TABLE R802.5.1(9)] ) / ( w STORAGE AND THE ERECTION OF ALL COMPONENTS SHALL BE AS PER THE MM). THE BACKGROUND OF THE SIGN OR SYMBOL SHALL BE GUARD IN-FILL COMPONENTSf 5CP Z =O W I- Lo 4. CEILING JOIST ATTACHED TO PARALLEL RAFTER PER TABLE FACE NAIL MANUFACTURER'S RECOMMENDATIONS. REFLECTIVE WHITE IN COLOR. THE CIRCLE AND CONTENTS SHALL BE 1 5. ALL DETAILING, FABRICATION AND ERECTION OF REINFORCING BARS, UNLESS d Q Q - � T (HEEL JOINT) [SEE SECTIONS R802.3.1 R802.3.2 AND R802.5.1(9) OTHERWISE NOTED, MUST FOLLOW THE LATEST ACI CODE AND THE LATTEST ACI REFLECTIVE RED IN COLOR, CONFORMING TO PANTONE MATCHING HANDRAIL 200h O JLO TABLE R802.5.1(9)] 5. ALL MULTIPLE LVL PRODUCTS SHALL HAVE (2) ROWS OF 1/2" DIA. GALVANIZED SYSTEM (PMS)#187. ~ w FACE NAIL "MANUAL OF STANDARD PRACTICE FOR DETAIUNG REINFORCED CONCRETE PASSENGER VEHICLE GARAGES 50 0- ca MACHINE BOLTS @ 12" O.C. 2,000° 5. COLLAR TIE TO RAFTER 3-1Od EACH RAFTER STRUCTURES". ALL EXTERIOR SHEATHING SHALL BE EXTERIOR GRADE, CDX PLYWOOD, 1 2 MINIMUM (2) THE SIGN OR SYMBOL SHALL BE OF STURDY, NON-FADING, - Q C0 6. / WEATHER-RESISTANT MATERIAL; PROVIDED, HOWEVER, THAT A SIGN OR AREAS OTHER THAN SLEEPING AREAS 40 (� LO 6. RAFTER OR ROOF TRUSS TO PLATE 2 TOE NAILS ON ONE 6. CONCRETE DESIGN MIX WILL BE SUBMITTED TO THE ENGINEER FOR REVIEW, SYMBOL APPLIED DIRECTLY TO A DOOR OR SIDELIGHT MAY BE A 3-10d THICKNESS. ALL SHEATHING SHALL BE NAILED 6D NAILS, 4" CENTERS AT EDGES AND SIDE AND 1 TOE NAIL 6" CENTERS IN THE FIELD. TOGETHER WITH LABORATORY REPORTS ATTESTING THAT THE MIXES CAN ATTAIN THE PERMANENT NON-FADING STICKER OR DECAL. SLEEPING AREAS 30 ON OPPOSITE SIDE OF MINIMUM STRENGTH REQUIRED IN ACCORDANCE WITH CHAPTER 3 OF A.C.I. 301-10. EACH RAFTER/TRUSS 7, ALL SUBFLOORING TO BE 3/4" T. & G. PLYWOOD. ALL EDGES OF (3) THE SIGN OR SYMBOL SHALL CONTAIN AN ALPHABETIC STAIRS 40c 300` 7. ROOF RAFTERS TO RIDGE. VALLEY OR HIP RAFTERS; OR 3-10d TOE NAIL PLYWOOD TO BE SET ON SOLID BLOCKING. GLUE AND NAIL PLYWOOD 7. NO ADMIXTURES ARE PERMITTED WITHOUT THE ENGINEER'S WRITTEN PERMIISSION CONSTRUCTION TYPE DESIGNATION TO INDICATE THE CONSTRUCTION For Sk 1 inch = 25.4 mm, 1 pound per square foot = 0.0479 kPa, 1 square inch = 645 mm2, 1 ROOF RAFTER TO 2-INCH RIDGE BEAM SUBFLOOR TO FLOOR JOISTS. OTHER THAN ENTRAINED AIR. CONCRETE EXPOSED TO THE WEATHER, SUCH AS TYPE OF THE RESIDENTIAL STRUCTURE, AS FOLLOWS: pound = 4.45N. THAT USED IN FOUNDATION WALLS, SHALL CONTAIN 5% + 1 ENTRAINED AIR2. a. Elevated garage floors shall be capable of supporting the uniformly distributed live load or a 2-16d END NAIL 8 ALL HEADERS 6'-0" AND OVER SHALL BE SUPPORTED WITH DOUBLE JACK (1) IF THE RESIDENTIAL STRUCTURE IS SUBJECT TO THE PROVISIONS 2,000-pound concentrated load applied on an area of 41 inches by 421 inches, whichever resses.er s ea g p ,OF THE RCNYS THE CONSTRUCTION TYPE DESIGNATION SHALL BE "V" produces the greater 1 STUDS. ALL HEADERS SHALL BE SIZED AS FOLLOWS, UNLESS SPECIFICALLY W A L_ L. F R A M II Iv G NOTED OTHERWISE ON THE DRAWINGS: 8. REINFORCING STEEL SHALL CONFORM TO ASTM A 615, GRADE 60. b. Uninhabitable attics without storage are those where the clear height between joists and (4) THE SIGN OR SYMBOL SHALL CONTAIN AN ALPHABETIC LOCATION rafters is not more than 42 inches, or where there are not two or more adjacent trusses 8. STUD TO STUD (NOT AT BRACED WALL PANELS) 16d 24„ O.C. FACE NAIL " DESIGNATION TO INDICATE THE LOCATIONS(S) CONTAINING TRUSS TYPE with web configurations capable of accommodating an assumed rectangle 42 inchesin height ~ g. OPENING SIZE: <3'-0" 3'-0" TO 6'-D" >6'-0-8'-0" 9. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR , 9. STUD TO STUD AND ABUTTING STUDS AT INTERES71ING 16 O.C. FACE NAIL HEADER SIZE: 2 2"x8" 2 2"x10" 2 2"x12 REINFORCEMENT: 16d ( ) ( ) ( ) CONSTRUCTION, PRE-ENGINEERED WOOD CONSTRUCTION AND/OR by 24 inches in width, or greater, within the plane of the trusses. This live load need not be y WALL CORNERS AT BRACED WALL PANELS R. " ( ) TIMBER CONSTRUCTION STRUCTURAL COMPONENTS, AS FOLLOWS: assumed to act concurrently with any other live load requirements. MINIMUM COVER (INCHES) 10. BUILT-UP HEADER (2" TO 2" HEADER WITH Xi" SIPACER) 16d 16" O.C. EACH EDGE 10. JOISTS AND GIRDERS SHALL HAVE FULL 3.5" MINIMUM BEARING OR AS PER c. Individual stair treads shall be capable of supporting the uniformly distributed live load or a FACE NAIL MAUNFACTURER'S SPECIFICATIONS. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO (1) "F"SHALL MEAN FLOOR FRAMING, INCLUDING GIRDERS AND BEAMS; 300-pound concentrated load applied on an area of 2 inches by 2 inches, whichever EARTH................................................................... 3 (II) "R"SHALL MEAN ROOF FRAMING; AND produces the greater stresses. 11. CONTINUOUS HEADER TO STUD 4-8d TOE NAIL 11. SOLID BLOCKING SHALL BE PROVIDED FOR ALL JOISTS AND FLOOR BEAMS AT (I11) "FR"SHALL MEAN FLOOR FRAMING AND ROOF FRAMING. d. A single concentrated load applied in any direction at any point along the top. For a guard 12. TOP PLATE TO TOP PLATE 16d 16" O.C. FACE NAIL CONCRETE EXPOSED TO EARTH OR WEATHER: 8'-0" O.C. OR AS PER THE WOOD FRAME CONSTRUCTION MANUAL, 1995 not required to serve as a handrail, the load need not be applied to the top element of the FACE NAIL ON EACH EDITION. #6 THROUGH #18 BARS............................................ 2 (5) THE CONSTRUCTION TYPE DESIGNATION SHALL BE PLACED AT THE guard in a direction parallel to such element. SIDE OF END JOINT #5 BAR AND SMALLER....................................... 1 1/2 12 O'CLOCK POSITION OF THE SIGN OR SYMBOL, OVER THE LOCATION e. See Section R507.1 for decks attached to exterior walls. --- 13. DOUBLE TOP PALTE SPLICE 8-16d (MINIMUM 24" LAP DESIGNATION WHICH SHALL BE PLACED AT THE SIX O'CLOCK f. Guard in-fill components all those except the handrail), balusters and panel fillers shall be ' t°L^O�.`if,. 12. ALL FRAMING SHALL BE DOUBLED UP AROUND ALL OPENINGS (SKYLIGHTS, P ( P ) P .c r. f'{ SPLICE LENGTH EACH CONCRETE NOT EXPOSED TO WEATHER POSITION OF THE SIGN OR SYMBOL. designed to withstand a horizontally applied normal load of 50 pounds on an area equal to 1 SIDE OF END JOINT STAIRS, ETC.) OR IN CONTACT WITH GROUND: square foot. This load need not be assumed to act concurrently with any other live load 14. BOTTOMPLATE TO BRACEDJOIST, RIMALL JOIST,PANEL )AND JOIST OR SLABS, 4BANDALI8 JOISTS: ........................................ 1 1 2 3. SIGNS CAN BE PURCHASED AT WWW.TRUSSID.ORG. g. Uninhabitable attics with limited storage are those where the clear height between joists and 16d 16 O.C. FACE NAIL 13. ALL FRAMING SHALL BE DOUBLED UP UNDER ALL PARTITION WALLS. # # / KING (NOT #1 1 BAR AND SMALLER......................................... 3/4 rafters is 42 inches or greater, or where there are two or more adjacent trusses with web ` 15. BOTTOM PLATE TO JOIST, RIM JOIST, BAND JOIST 2_16d (2) EACH 16" O.C. 14. TOE NAILING OF JOIST TO HEADER IS NOT PERMITTED; USE 16 GA. STANDARD g 1 <... .»'. configurations capable of accommodating an assumed rectangle 42 inches in height by 24 OR BLOCKING (AT BRACED WALL PANELS) FACE NAIL JOIST HANGERS WHEREVER JOISTS FRAME TO SIDE OF HEADER. BEAMS, COLUMNS: tii ,✓ a inches in width, or greater, within the plane of the trusses. `.;'=�f>:;`.�'>,?..,A",='�� PRIMARY REINFORCEMENT, TIES, 16. TOP OR BOTTOM PLATE TO STUD 4-8d TOE NAIL STIRRUPS, SPIRALS 1 1 2 The live load need only be applied to those portions of the joists or truss bottom chords where all ............ ...................... 15. ALL WOOD EXPOSED TO WEATHER SHALL BE 'ACQ TREATED IN of the followin conditions are met: 1 K 2-16d END NAIL ACCORDANCE WITH AWPA STANDARDS. g -`-- - 10. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A 185 WITH A MINIMUM YIELD 1. The attic area is accessed from an opening not less than 20 inches in width by 30 inches in 17. TOP PLATES, LAPS AT CORNERS AND INTERSECTIO)NS 2-16d FACE NAIL 18. 1" BRACE TO EACH STUD AND PLATE 2-8d FACE NAIL CONTRACTOR SHALL SUPPLY ALL TEMPORARY BRACING OF THE STRUCTURE, AS STRENGTH OF 70 KSI. LAP ONE MESH SIZE AT SIDES AND ENDS, APND WIRE length that is located where the clear height of the attic is not less than 30 inches. 16. TOGETHER. 2. The slopes of the joists or truss bottom chords are not greater than 2 units vertical in 12 N REQUIRED, UNTIL ALL EXTERIOR SHEATHING HAS BEEN INSTALLED. P ) g L_ 19. 1"W SHEATHING TO EACH BEARING 2-8d FACE NAIL units horizontal. 11. CONCRETE SLABS SHALL BE PROTECTED FROM LOSS OF SURFACE MOISTURE FOR =3 20. 1"X8" AND WIDER SHEATHINGEACH O TO CH BEARING 3-8d FACE NAIL 17 ALL WOOD CONNECTIONS SHALL BE MANUFACTURED BY SIMPSON STRONG TIE NOT LESS THAN 7 DAYS BY USING A CURING COMPOUND CONFORMINIG TO ASTM 3. Required insulation depth is less than the joist or truss bottom chord member depth. U 0 AND INSTALLED PER THE MANUFACTURER'S SPECIFICATIONS. C-309 OR BY WET BURLAP OR A PLASTIC MEMBRANE. The remaining portions of the joists or truss bottom chords shall be designed for uniformly � -�-' M FLOOR FRAM II N G distributed concurrent live load of not less than 10 pounds per square foot. ,� (D ti 21. JOIST TO SILL, TOP PLATE OR GIRDER 3-8d TOE NAIL 18. ALL CONNECTIONS SHALL BE MADE AS INDICATED IN THE NAILING SCHEDULE. h. Glazing used in handrail assemblies and guards shall be designed with a load adjustment -� C) .� ALL NAILS SHALL BE GALVANIZED. 12. NO WELDING OF REINFORCING WILL BE PERMITTED. factor of 4. The load adjustment factor shall be applied to each of the concentrated loads Q (n ",- C\I U 22. RIM JOIST, BAND JOIST, OR BLOCKING TO SILL 8d 6" O.C. TOE NAIL applied to the top of the rail, and to the load on the in-fill components. These loads shall >- CD 2 OR TOP PLATE OR OTHER FRAMING BELOW 19. ALL ROOF RAFTERS SHALL BE ATTACHED TO THE TOP PLATE AND STUD WITH be determined independent of one another, and loads are assumed not to occur with any t6 z I` 23. 1"X6" SUBFLOOR OR LESS TO EACH JOIST 2-8d FACE NAIL (n LO i GALVANIZED HURRICANE CONNECTORS AS INDICATED ON THE DRAWINGS. other live load. > � ti 24. 2" SUBFLOOR TO JOIST OR GRIDER 2-16d BLIND AND FACE NAIL i. Where the top of a guard system is not required to serve as a handrail, the single 0O r' CU 20. PROVIDE 'SIMPSON' POST CAP AND BASE CONNECTIONS FOR ALL POST TO concentrated load shall be applied at any point along the top, in the vertical downward +r N M CO 25. 2" PLANKS (PLANK AND BEAM -FLOOR AND R00)F) 2-16d EACH BEARING, GIRDER/HEADER CONNECTIONS TYPICAL THROUGHOUT. REFER TO PLANS FOR SPECIFIC direction and in the horizontal direction away from the walking surface. Where the top of a J W O V FACE NAIL TYPE AND A?PLICATION. guard is also serving as the handrail, a single concentrated load shall be applied in any (.0 � rn 26. BAND OR RIM JOIST TO JOIST 3-16d END NAIL MINIMUM PIPE INSULATION co ~ � NAIL EACH LAYER AS 21. PROVIDE 'SIMPSON' HURRICANE TIES FROM RAFTERS TO STUDS AT EXTERIOR WALLS direction at any point along the top. Concentrated loads shall not be applied concurrently. _ 20d FOLLOWS: 32" O.C. AND CS20 COIL STRAPPING FROM FLOOR-TO-FLOOR AND WALL TO PLATE CONNECTIOS. 27. BUILT-UP GIRDERS AND BEAMS, 2" LUMBER LAYEERS AT TOP AND BOTTOM REFER TO STANDARD STRAPPING DETAILS. TABLE 503.3.3.1 CU AND STAGGERED Q 2-20d FACE NAIL AT ENDS 22- PROVIDE SPECIAL HEAVY DUTY AND SKEWED METAL HANGERS AS MAY BE REQUIRED TO TABLE R301.6 AND AT EACH SPLICE TRANSFER ALL LOADS. PPIPE SIZES PIPING FLUID MINIMUM ROOF LIVE LOADS IN POUNDS-FORCE 28. LEDGER STRIP SUPPORTING JOISTS OR RAFTERS 3-16d AT EACH JOIST OR SYSTEMS TEMPERATURE RAFTER, FACE NAIL TYPES RANGE, ?F. RUNOUTS 1" AND 1.25" 'TO 2.5" TO 5" TO 6" 8" AND PER SQUARE FOOT OF HORIZONTAL PROJECTION UP TO LESS 2" 4" LARGER TABLE R301.7 29. BRIDGING OR BLOCKING TO JOIST 2-10d EACH END. TOE NAIL 2" (b) ALLOWABLE DEFLECTION OF 0 EDGES INTERMEDIATEROOFING NOTES: TRIBUTARY LOADED AREA IN SQUARE 0 (INCH.) SUPPORTS HEATING SYSTEMS ROOF SLOPE FEET FOR ANY STRUCTURAL MEMBER STRUCTURAL MEMBERS" Z () 30. - Yz" 6d (SUBFLOOR, WAALL), 8d (ROOF) 6 12 1, ALL ROOFS WITH A PITCH LESS THAN 3:12 SHALL HAVE A FULLY ADHERED 60 STEAM AND OR RSRS-01 RO)OF MIL. EPDM ROOF MEMBRANE. HOT WATER 0 TO 200 201 TO 600 OVER 600 ALLOWABLE » HIGH PRESSURE/ STRUCTURAL MEMBER DEFLECTION 31. 12 - 1 8d OR RSRS;-01 (ROOF) 6 12 2. ALL ROOF SYSTEMS SHALL BE INSTALLED AS PER THE MANUFACTURER'S TEMP. 306-450 1-1/2" 2-1/2" 2-1/�" 3" 3-1/2" 3-1/2" FLAT OR RISE LESS THAN 4 INCHES 32. 17�"- %* 10d1 6 12 SPECIFICATIONS. MEDUIM PRESSURE/ 251-305 1-1/2" 2" 2-1/22" 2-1/2" 3" 3" PER FOOT (1:3) 20 16 12 RAFTER HAVING SLOPES GREATER THAN }' OT R HE 1-XTE OR L L S EAT G TEMP. RI VWAHHIN 3:12 WITH FINISHED CEILING NOT ATTACHED L/180 z 3. ALL FLASHING REQUIRED AT VALLEYS, CHIMNEYS, CRICKETS AND ROOF LOW PRESSURE/ TO RAFTERS W 2oi-25o 1" 1-1/2" t-1/7Z" 2" 2" 2" RISE 4 INCHES PER FOOT (1:3) TO nn// z 33. Y2" STRUCTURAL CELLULOSIC " 3 6 PENETRATIONS SHALL BE COPPER. TEMP. 16 14 12 LLL 1Xz GALVANIZED IROOFlNG NAIL LESS THAN 12 INCHES PER FOOT (1:1) INTERIOR WALLS AND PARTITIONS H/180 0 FIBERBOARD SHEATHING LOW 1 o6-200 1/ / / /2" 1" 1" 1-1 2" 1-1 2" 1-1 2" 4. ROOF DRAINS SHALL BE INSTALLED ON LOW PITCHED ROOFS. THESE DRAINS TEMPERATURE W FIB 2ERBOARD SHEATHING STEAM�32" STRUCTURAL CELLULOSIC 13'a" GALVANIZED ROOFING NAIL 3 6 SHALL BE PIPED TO AN EXTERIOR WALL OF THE DWELLING AND CONNECTED TO RISE 12 INCHES PER FOOT (1:1) FLOORS FIB 12 12 12 L/360 W Q THE UNDERGROUND STORM WATER SYSTEM. ALL PIPING SHALL BE PVC AND GREATER " CONDENSATE ANY 1" 1" 1-1/22" 2" 2" 2"35. Y2" GYPSUM SHEATHING GALVANIZED WOOFING WITH BRITTLE FINISHES (INCLUDING NAIL 7 7 SCHEDULE-40. (FOR FEED WATER) ( CLUDING L/360 � For SI: 1 square foot= 0.0929 m2. 1 pound per square foot= 0.0479 kPo, PLASTER AND STUCCO) Z >_ F- 36. X2" GYPSUM SHEATHING 1�i'4" GALVANIZED Fi200FlNG NAIL 7 7 COOLING SYSTEMS 1 inch per foot= 83.3 mm/m. WOOD STRUCTURAL PANIELS, COMBINATION INSULATION / VENTILATION NOTES: CEILINGS WITH FLEXIBLE FINISHES L/240 O z Q CHILLED WATER, 40-55 1/2" 1/2' 3/4' t' 1' 1' (INCLUDING GYPSUM BOARD) � W SUBFLOOR IJNI:3ERLAYME-=NT TO FRAMING REFRIGERANT ALL OTHER STRUCTURAL MEMBERS Q 0 1. THIS PROJECT HAS BEEN DESIGNED TO MEET THE NEW YORK STATE ENERGY CODE, AND BRINE: BELOW 40 1" 1" t-t/22" 1-1/2" 1-1/2" 1-1/2" L/240 37. -Y4" AND LESS 8d 6 12 LATEST EDITION. THERE SHALL BE NO DEVIATION IN STATED VALUES OF ANY EXCLUDING GUARDS AND HANDRAILS "- 1 8d 6 12" INSULATION COMPONENT INDICATED ON THESE DRAWINGS. EXTERIOR WALLS-WIND LOADS" WITH Q W 0 38, �� FOR SI: 1 INCH = 25.4 mm, 1 FOOT = 304.8 mm, C = [(-F`)-30]/1.8 TABLE R402.2 H/360 Q co a. FOR PIPING EXPOSED TO OUTDOOR AIR, INCREASE INSULATIOPN THICKNESS BY 0.5 INCH PLASTER OR STUCCO FINISH 39. 1X"-1Y4" 1Od 6 12 2. ALL PENETRATIONS THROUGH FLOORS AND RIM JOISTS FOR ELECTRICAL AND b. RUNOUTS NOT EXCEEDING 12 FEET IN LENGTH TO INDIVIDUAL TERMINAL UNITS. MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE U W MECHANICAL / PLUMBING ACCESS ARE TO BE FILLED COMPLETELY WITH EXTERIOR WALLS-WIND LOADS° WITH OTHER H/240 EXPANDING FOAM SEALANT AFTER WORK HAS BEEN COMPLETED. MINIMUM PIPE INSULATION BRITTLE FINISHES J TABLE 504.5 MINIMUM SPECIFIED COMPRESSIVE STRENGTHa f' 0 0 Q TYPE OR LOCATION OF ( �) EXTERIOR WALLS-WIND LOADS° WITH H/120d 3. ALL CAVITIES AT WINDOW AND DOOR ROUGH OPENINGS ARE TO BE FILLED PIPE SIZES CONCRETE CONSTRUCTION WEATHERING POTENTIALb FLEXIBLE FINISHES COMPLETELY WITH MINIMAL EXPANDING FOAM SEALANT SPECIFICALLY DESIGNED SERVICE WATER LINTELS SUPPORTING MASONRY VENEER W U LO FOR WINDOW AND DOOR USE. HEATING NON-CIRCULATING LTING CIRCUI.ATIN(G MAINS AND RUNOUTS NEGLIGIBLE MODERATE SEVERE WALLSe L/600 N N L1- M TEMPERATURES ?F 4. ALL DOOR UNITS SHALL BE SET IN SEALANT AS PER THE INSTALLATION UP TO 1" UP TO 1.25" 1.50" TO 2" OVER 2" BASEMENT WALLS, FOUNDATION AND OTHER 2500 2500 2500� NOTE: L = span length, H = span height. 1- a.CONCRETE NOT EXPOSED TO WEATHER , , , For the purpose of determining deflection limits herein, the GUIDELINES PROVIDED BY THE MANUFACTURER. wind load shall be permitted to be taken as 0.7 times the W W W Q 170-180 0.5" 1.0" 1.5" 2'0 BASEMENT SLABS AND INTERIOR SLABS ON component and cladding (ASD) loads obtained from Table W U) W 140-139 0.5" 0.5" 1.0" 1.5" GRADE, EXCEPT GARAGE FLOOR SLABS 2,500 2,500 2,500` R301.2.1(1). O O 0 WINDOWS AND DOORS: b. For cantilever members, L shall be taken as twice the length 0- W 0- W BASEMENT WALLS, FOUNDATION WALLS, 100-139 0.5" 0.5" 0.5" 1.0" of the cantilever. 2,500 3,000' 3,000' c. For aluminum structural members or panels used in roofs or O O 0 0- 1. WINDOWS AND DOORS SHALL BE INSTALLED IN ACCORDANCE WITH THE FENESTRATION EXTERIOR WALLS AND OTHER VERTICAL p 0 MANUFACTURERS' INSTALLATION INSTRUCTIONS AND FLASHED IN ACCORDANCE WITH CONCRETE WORK EXPOSED walls of sunroom additions or patio covers, not supporting the n/ n/ n/ FOR Sk 1 INCH = 25.4 mm, C = [(?F)-30]/1.8, edge of glass or sandwich panels, the total load deflection LL LL LL SECTION R703.4. 1 BTU H INCH ft2 ?F = 0.144 W m-K . / / /( ) PORCHES, CARPORT SLABS AND STEPS of def shall not exceed L/60. For continuous aluminum structural o. NOMINAL IRON PIPE SIZE AND INSULATION THICKNESS. CONLDUCTIVITY, k = .027 EXPOSED TO THE WEATHER, AND GARAGE 2,500 3,000d 3,000 members supporting edge of glass, the total load deflection 2. EXTERIOR WINDOWS AND DOORS SHALL BE DESIGNED TO RESIST THE DESIGN WIND FLOOR SLABS shall not exceed L/175 for each glass lite or L/60 for the LOADS SPECIFIED IN TABLE R301.2(2) ADJUSTED FOR HEIGHT AND EXPOSURE IN Date: 02/02/26 ACCORDANCE WITH TABLE R301.2.12 FOR SI: 1 POUND PER SQUARE INCH = 6.895 kPa. entire length of the member, whichever i more stringent. For ( ) OR DETERMINED IN ACCORDANCE WITH ASCE 7 a. Strength at 28 days si sandwich panels used in roofs or walls off sunroom auditions USING THE ALLOWABLE STRESS DESIGN LOAD COMBINATIONS OF ASCE 7. DESIGN WIND g y psi. or patio covers, the total load deflection shall not exceed Scale: b. See Table R301.2 for weathering potential. NOTED LOADS FOR EXTERIOR GLAZING NOT PART OF A LABELED ASSEMBLY SHALL BE g p L/120. PERMITTED TO BE DETERMINED IN ACCORDANCE WITH CHAPTER 24 OF THE c. Concrete in these locations that is subject to freezing and thawing during construction shall be air-entrained d. Deflection for exterior walls with interior gypsum finish shall be INTERNATIONAL BUILDING CODE. concrete in accordance with Note d. limited to an allowable deflection of H/180. Drawn: BAJ d. Concrete shall be air-entrained. Total air content (percent by volume of concrete) shall be not less than 5 e. Refer to Section R703.8.2. The dead load of supported 3. EXTERIOR WINDOWS AND SLIDING DOORS SHALL BE TESTED BY AN APPROVED percent or more than 7 percent. materials shall be included when calculating the deflection of Job: INDEPENDENT LABORATORY, AND BEAR A LABEL IDENTIFYING MANUFACTURER, e. See Section R402.2 for maximum cementitious materials content. these members. PERFORMANCE CHARACTERISTICS AND APPROVED INSPECTION AGENCY TO INDICATE f. For garage floors with a steel-troweled finish, reduction of the total air content (percent by volume of Sheet COMPLIANCE WITH AAMA/WDMA/CSA 101/I.S.2/A440. EXTERIOR SIDE-HINGED DOORS concrete) to not less than 3 percent is permitted if the specified compressive strength of the concrete is SHALL BE TESTED AND LABELED AS CONFORMING TO AAMA/WDMA/CSA 101/I.S.2/A440 A 1 OR AMD 100, OR COMPLY WITH SECTION R609.5.OR to not less than 4,000 psi. of - Sheets