Loading...
HomeMy WebLinkAbout52561-Z �o4"XOf s0(/Tyo(o Town of Southold P.O. Box 1179 • c4 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 47265 Date: . 08/04/2026 THIS CERTIFIES that the building SINGLE FAMILY DWELLING-ADDITION AND ALTERATION Location of Property: 710 Old Menhaden Rd CutchoQue, NY 11935 Sec/Block/Lot: 111.-4-19 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 10/27/2025 Pursuant to which Building Permit No. 52561 and dated: 12/17/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Additions and alterations including conversion of a portion of the attached garage to habitable space to an existing single-family dwelling as applied for. The certificate is issued to: Daniel McNeill , Sophie McNeill Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 52561 7/27/2026 PLUMBERS CERTIFICATION: Michael Ridolfi 7/22/2026 Aut ed ignature �aoFsoaTy° TOWN OF SOUTHOLD BUILDING DEPARTMENT `� • SOUTHOLD, NY .n y o�rCou�r�� BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52561 Date: 12/17/2025 Permission is hereby granted to: Daniel McNeill 17 Framfield Rd London, N51UU To: Construct additions and alterations to an existing single-family dwelling as applied for to include converting a portion of the garage to habitable space, relocating HVAC,interior alterations and creating a second story bedroom.Amended 4/14/26 to include basement egress stairwell. Premises Located at: 710 Old Menhaden Rd, Cutchogue, NY 11935 SCTM# 111.4-19 Pursuant to application dated 10/27/2025 and approved by the Building Inspector. To expire on 12/17/2027. Contractors: Required Inspections: i Fees: Single Family Dwelling- Addition&Alteration $1,227.00 CO Single Family Dwelling-Addition/Alteration $100.00 ELECTRIC -Residential $250.00 Amendment Fee $0 Total $1,S77.00 j�� Building Inspector pf BOO TOWN OF SOUTHOLD BUILDING DEPARTMENT SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52561 Date: 12/17/2025 Permission is hereby granted to: Daniel McNeill 17 Framfield Rd London, N51UU To: Construct additions and alterations to an existing single-family dwelling as applied for to include converting a portion of the garage to habitable space, relocating HVAC,interior alterations and creating a second story bedroom. Premises Located at: 710 Old Menhaden Rd, Cutchogue, NY 11935 SCTM# 111.4-19 Pursuant to application dated 10/27/2025 and approved by the Building Inspector. To expire on 12/17/2027. Contractors: Required Inspections: Fees: Single Family Dwelling- Addition&Alteration $1,227.00 CO Single Family Dwelling-Addition/Alteration $100.00 Total $1,327.00 Building Inspector o��pF SO(/j�ol � o Town Hall Annex Telephone(631)765-1802 54375 Main Road N P.O.Box 1179 Southold,New York 11971-0959 ��iYcom,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Daniel MvNeill Address: 710 Menhaden Rd City: Cutchogue st: NY zip: 11935 Building Permit#: 52561 Section: 111 Block: 4 Lot: 19 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Electrician: We Electric License No: 5230ME SITE DETAILS Office Use Only Commercial Indoor X Basement X Service Solar Residential X Outdoor X 1st Floor X Pool Battery Storage As-built Renovation X 2nd Floor X Hot Tub EV Charger New X Addition X Attic X Spa Generator Survey Mezzanine Garagel IDock INVENTORY Service 1 ph In-wall Heater Recpt 60 Ceiling Fixtures 5 Smoke Detectors 4 Pump Service 3 ph Hot Water Gas GFCI Recpt Wall Fixtures 3 CO Detectors Heater Main Panel A/C Condenser 2 Single Recpt RecessdFixtures 49 Combo Smoke/CO 3 Transformer Sub Panel 80A A/C Blower 2 Range Recpt 50A Ceiling Fan Heat Detectors 1 Salt Gen Transfer Switch Mini Split Dryer Recpt 30A UC Lights 6' Fridge 1 AutoCover ARC 6 Blower Heads Switches 53 Pucks Lights Dishwasher 1 Mini Fridge 1 GFI SepticDisconnect Emrgency Strobe 4'LED Microwave 1 Garbage Disp. ARC/GFI 8 ERV Exit Lights Bath Exhaust 6 Hood 1 Dehumidifier 1 Other Equipment: Towel Warmer(3), PlugMold 12', LED Mirror(3), 80A Panel 12 Circuit/11 Used Notes: Two Story House w/ Unfinished Basement Inspector Signature: — Date: July 27, 2026 Off' G Telephone(631)765-1802 Town Hall Annex � :,�T.��F F'' �. y� 54375 Main Road a ,J P.O.Box 1179. N Southold,NY 11971-0959 AUG 3 2026 BUILDING DEPARTMENT �4 TOWN OF SOUTHOLD Building Department i Town of Southold i CERTIFICATION i ) Date: Building Permit No. `Owner: SuQ`.�e--t h,�tsie,� til l (Please print) Plumber. � ;� (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1%lead. bers Signature) Sworn to before me this JZ • day of —� Notary Public, �o ( K County L' - LAURAMALL011 4 Notary Public,State of Neu York No.01MA6164238 Qualified In Suffolk County 1 Commission f xpires April 16,20.E 9 OF SOUIyo� _ # TOWN OF SOUTHOLD BUILDING DEPT. °yi'oorm,�'' 631-765-1802 INSPECTION [�UNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: ,nn DATE I ' INSPECTOR - �`� # TOWN OF SOUTHOLD BUILDING DEPT. coo rm��' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ]. RENTAL REMARKS: �[7 v eA 4-p �2"" DATE INSPECTOR a souryolo 5 2-G,- 71 C--) G rc� # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ], PRE C/O [ ] RENTAL REMARKS: E ci e � ZI , 1 k�s qj\c� w_t t /'e DATE INSPECTOR �OF SOUTyO� �/vcn N TOWN OF SOUTHOLD BUILDING DEPT. i'oum, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ OUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ RAMING /STRAPPING [ ] .FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: i&AIA (vlM- �� al!5-s-u1zp- a.i-es DATE r'�5�a� INSPECTOR OF SOpr�o� # # TOWN OF SOUTHOLD BUILDING DEPT. `ycourm, 631-765-1802 1 N S PECTION [ UNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: �"�Y� 0 K T-- I A-q c/1v DATE 1*7 OE SOUIyOlo TOWN OF SOUTHOLD BUILDING DEPT. C'oum��' 631-765-1802 INSPECTION [ ] FO NDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: U"tie I m/w �0 DATE S/ aVP INSPECTOR T _ OP SOUT,y�� # # TOWN OF SOUTHOLD BUILDING DEPT. co 631-765-1802 ( tNSPECTION [ -] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] -I LATION/CAULKING [ ] 'FRAMING/STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] ,FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL). [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: Q &On�f� CO . � cakt�& L DATE INSPECTOR pE SOUTyoI r . # . # TOWN OF SOUTHOLD BUILDING DEPT. ��TYOOUrm a�'�o 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) LECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O [ ] RENTAL REMARKS. r - f Crlg 00 cr-o_40• ko z r tovV - JATE Z© INSPECTOR ho��OF SOUIyOIo 525 0 C `71 G (3 rC( M en k4if, # * TOWN OF SOUTHOLD BUILDING DEPT. Coum,N 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ��LECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE 7 2 INSPECTOR t FIELD INSPECTION REPORT DATE COMNltKNTS nn 0 y- FOUNDATION (1ST) ------------------------------------ 04 o� /� FOUNDATION (2ND) � t� 20. God n z s av arth1 y ROUGH FRAMING& , y PLUMBING l S � r INSULATION PER N.Y. STATE ENERGY CODE or FINAL ADDITIONAL COMMENTS 12- a= 19 10+ C 0 ire G-Ak 111 14G9 �- -\ a Id K X J y N Z x y x d y I ��o�gOFFOIKcoGy TOWN OF SOUTHOLD—BUILDING DEPARTMENT y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 �y�oi ao� Telephone (631) 765-1802 Fax (631) 765-9502 hgps://www.southoldtonm.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only D PERMIT NO. Building Inspector: J4 L 0CT 7 2 2025 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an Building Department Owner's Authorization form(Page 2)shall be completed. Tovvn of Southold Date:08.26.25 OWNER(S)OF PROPERTY: Name:DANIEL & SOPHIE MCNEILL scTM# Z000-111-4-19 Project Address:710 OLD MENHADEN ROAD CUTCHOGUE NY 11935 Phone#:+44 755 594-7734 Email:SOPHIE.MCNEILL HOTMAIL.COM Mailing Address:710 OLD MENHADEN ROAD, CUTCHOGUE, NY 11935 CONTACT PERSON: Name:STEPHEN SCHEIBLY Mailing Address 255 MAIN STREET, SUITE 200, HUNT,INGTON, NY 11743 a_ y Phone#: Email SSCHEIBLY(631)_271-5400 x 102 r _ ..._�. @DDANY.NET DESIGN PROFESSIONAL INFORMATION: Name:STEPHEN SCHEIBLY, R.A. DIVERSIFIED DESIGN ASSOCIATES ARCHITECTS, P.C. Mailing Address 255 MAIN STREET, SUITE 200 HUNTINGTON NY 11743 Phone#: Email: Y DDANY.NET _.�__(631)_271-5400 x_102 _ - _ -a—_ SSCHEIBL_. @=M� _- -�_ CONTRACTOR INFORMATION: Name:T.B.D. Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure WAddition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $ Will the lot be re-graded? ❑Yes ONo Will excess fill be removed from premises? ❑Yes ®No 1 PROPERTY INFORMATION Existing use of property:SINGLE FAMILY RESIDENCE Intended use of property:SINGLE FAMILY RESIDENCE Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R-40 this property? ❑Yes WNo IF YES, PROVIDE A COPY. W Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues'as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk;County,New York and other applicable Laws;Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name):STE P H E N SC H E I B LY BAuthorized Agent El Owner Signature of Applicant: Date: Nevada ST eEac os r JomllaTan H STATE OF PAW)YxQR�) ��` F<<I�;; NOTARY PUBLIC SS: o STATE OF NEVADA ) COUNTY OF Clark "" Appt.N0.24-2299-01 •,NeVADP •• Expires November 21,2028 DANIEL OWEN MCNEILL being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)he is the AGENT (Contractor,Agent,Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 21 day of September 20 25 00— ___��'Notary Public,State of Nevada Notary Public Notarized remotely using audio-video communication technology via Proof. PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I, DANIEL OWEN MCNEILL residing at 710 OLD MENHADEN ROAD, CUTCHOGUE, NY,11217 do hereby authorize STEPHEN SCHEIBLY to apply on my behalf to the Town of Southold Building Department for approval as described herein. DANIEL OWN114CA16M 09/21/2025 Owner's Signature Date DANIEL OWEN MCNEILL Print Owner's Name 2 2 BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD '��i -'� : .`ryTown Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 +a gifts _�'3►'°` IT APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 03/12/2026 Company Name: Vue Electric Inc Electrician's Name: Joseph Piscatello License No.: 5230-ME Elec. email:joe@vueelectric.com Elec. Phone No: 5168052606 ❑✓ I request an email copy of Certificate of Compliance Elec. Address.: 365 Kirkup Ln Mattituck, NY 11952 JOB SITE INFORMATION (All Information Required) Name: McNeill Address: 710 Old Menhaden Cutchogue, NY Cross Street: Haywaters Phone No.: 631-926-4459 -Nautilus Contracting-Erik Johansen Bldg.Permit#: email: ericj@nautiluscontracting.com Tax Map District: 1000 Section: 111 Block: 4 Lot: 19 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Renovation Square Footage: 15 7 00 Circle All That Apply: Is job ready for inspection?: YES ❑ NO 0 Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals M 1 2 H Frame Pole Work done on Service? DY N Additional Information: PAYMENT DUE WITH APPLICATION WILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD ;;; n 'l"own Hall Annex- 54375 Main Road - PO Box 1179 } ` Southold, New York 11971-0959 _ 4"' Telephone (631) 765-1802 APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 03/12/2026 Company Name: Vue Electric Inc Electrician's Name: Joseph Piscatello License No.: 5230-ME Elec. email:joe@vueelectric.com Elec. Phone No: 5168052606 0✓ I request an email copy of Certificate of Compliance Elec. Address.: 365 Kirkup Ln Mattituck, NY 11952 JOB SITE INFORMATION (All Information Required) Name: McNeill Address: 710 Old Menhaden Cutchogue, NY Cross Street: Haywaters Phone No.: 631-926-4459 -Nautilus Contracting-Erik Johansen Bldg.Permit#: j�, ➢ email: ericj@nautiluscontracting.com Tax Map District: 1000 Section: 111 Block. 4 Lot: 19 BRIEF DESCRIPTION.OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Renovation Square Footage: Circle All That Apply: Is job ready for inspection?: YES ❑ NO 0 Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 0 1 2 H Frame Pole Work done on Service? Y F1N Additional Information: PAYMENT DUE WITH APPLICATION PERMIT# Address: S� Switches Sw Outlets GFI's v _ Surface J" t Sconces C r HH � I UC Lts f Fridge HW POOL Fans Mini Fr.�-- ...- W/D, Panel Pump � .Exhaust Ovene.]G-(-. Sump Heater Trnsfmr Smokes ( DW ( Generator Salt Gen. 1 1 Water Bond Carbon Micro P GrbDs Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo ' Cooktop Minisplit ,, Blower AC AH' ! Hood I Blower Service Amps Have Used Sub Amps ED Have t/2,,,Used Comments u4-1 h r� V� - eeryf D15T: /000 5ECTION: / / i BLOCK: 4 TAX LOT: 19 SURVEY NO. 25-28258 TITLE.NO. THE OFFSETS OR DIMENSIONS SHOWN HEREON. FROM THE PROPERTY LINES TO THE STRUCTURES. ARE FOR A SPECIFIC PURP65E AND' USE: c THEREFORE THEY ARE NOT INTENDED TO MONUMENT THE PROPERTY LINES OR70 GUIDE THE �p ERECTION OF FENCES. ADDITIONAL STRUCTURES OR ANY OTHER IMPROVEMENT `�nu, s��� 0, (y n.(/� po 3:0, tIT.5'-3" ibIQ�.N7. I'-9 PE. 3/t „ ., SHEZ =� & rvP W.� ,��J t07-Nl 34j n =c L0 20, 7-NO 346 /OL3n l7LIn 2 _ Q i COA4poOS7� KIALL U LOrN0 345 R � yT 0 L8" pq CK gyp. NCB " I G_s�„ GATC UN� Q �" 2nd 31Y O I3' 2 A(c' 7/0 9L/O p8V CCONY O STD G C° ER PLAY tt) 4 D�PwMRY ° GA7Lc E,OLl„-E. N /w/V ING tl 8L3o RIOW, ";�s 9`'ORCy a I J V �O Q 'o o z 0 J y f� A U V o; CVro ® �:o° NE WAS L `V L O � ti 5?AO�p 5? SY ,��• H7 �.3" D 4 7OIVF WA� FE O,/o, clu MAP OF PROPERTY ���� SITUATE AT ISLAND WIDE LAND SURVEYORS PROFE55IONAL LAND 4 CITY SURVEYORS C I TC.HOGLIE 199 LAFAYE7TE DRIVE,SY055ET, N.Y. 11791 6J Pi10NE: I-866-808-5'SOc? FAX: 516-496-1792 TOWN OF SOUTHOLD EMAIL: OFFICE@ISIANDWIDE5UPVEYOR5.COM RECORD5 OF WALTER I.BROWN,GU5TAVE A.ROULUM 3UFFOLK COUNTY, N. Y. 4 ROBERT A.HAYNES UNAUTHORIZED ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION OF SECTION 7209'OFTHE NEW YORKSTATE 5URVEYED :MAY 28, 2025 .,E EDUCATION LAW. a , COPIES OF THI5 SURVEY MAP NOT BEARING THE LAND SURVEYOR'S INKED 5EAL OR GUARANTEED TQ :- EM5055ED SEAL SHALL NOTE CONSIDERED To BE A VAUD TRUE COPY. FOR'BUILDING DEPARTMENT PURP05E ONLY GUARANTEES OR CERTI19CATION5 INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY I5' PREPARED, AND ��r°r.:;�; �V r ON HI5 BEHALF TO THE TITLE COMPANY, I•• ,�: ;, GOVERNMENTAL AGENCY AND LENDING IN5TITUTION U5TED HEREON, AND TO THE A551GNEES OF THE LENDING INSTITUTION. LOT N U MBER5: GUARANTEES OR CERTIFICATIONS ARE NOT LOT No. 346 TRANSFERABLE TO ADDITIONAL INSTITUTIONS �� OR SUBSEQUENT OWNERS. MAP OF 3ECTION D, MA55AU POINT CLUB PROPERTIES, I —;.,�r✓,�,/; .„;�,,,,,,,,,.�°;i��'" DRAFTED.BY P:G, MAY 31,zo25 FILED: MARCH 24, l 92G AB MAP No. COG ` •''�'�, gtl�v l� d do DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, PC LETTER OF TRANSMITTAL VIA FEDERAL EXPRESS TO: Town of Southold Building Dept. DATE: 10.23.25 P.O.Box 1179 JOB NO.: 2515 Southold,NY 11971-0959 RE: McNeill Residence 710 Old Menhaden Road Cutchogue, NY 11935 ATTN.: WE ARE SENDING YOU ® Attached ❑ Shop Drawings ❑ Copy of letter ❑ Blueprints ❑ Vellums COPIES DATE NO. DESCRIPTION 4 10.20.25 FULL SET Signed and sealed architectural drawings 4 05.28.25 Survey 1 08.26.25 Signed building permit application packet 1 ResCheck THESE ARE: ❑For approval ®For your use ❑As requested ❑For review and comment ❑As discussed TRANSMITTED: ❑Approved as submitted ❑Approved as noted ❑ Returned for corrections REMARKS: Enclosed please find our application package for building permit. If possible,please confirm receipt. Sharon Ernst sernst@_ddany.net 631.271.5400 x 105 COPY: SIGNED: Sharon Ernst 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 P 631.271.5400 F 631.271.4844 � RE'Sc- ,h�e-,, ,c-k,,* , ,�W,,,,,ebT" Compliance Certificate Project Information Project Title: McNeill Residence Energy Code: 2018 IECC Location: Cutchogue, New York Construction Type: Single Family Project Type: Addition Project Sub Type: None Glazing Area: 9% Climate Zone: 4a (5572 HDD) All Electric: false Is Renewable: false Has Battery: false Has Charger: false Has Heat Pump false Construction Site: Owner/Agent: Designer/Contractor: 710 Old Menhaden Road Dan&Sophie McNeill Stephen Scheibly Cutchogue, NY 11935 710 Old Menhaden Road 255 Main Street Cutchogue, NY 11935 Diversified Design Associates,Architects P.C. +44(755)594-7734 Huntington, NY 11743 sophie.mcneill@hotmail.com 631.271.5400 x 102 sscheibly@ddany.net Project Notes: Envelope Assemblies Prop. Req. Assembly Gross Area or Cavity Cont. U- U- Prop. Req. Perimeter R-Value R-Value Factor/ Factor/ UA UA F-Factor F-Factor Ceiling: Flat Ceiling or 294 30.0 0.0 0.035 0,026 10 8 Scissor Truss Floor:All-Wood 261 30.0 0.0 0.033 0.047 9 12 joist/Truss Wall: Wood Frame, 16" 673 21.0 0.0 0.057 0.060 34 36 O.C. Window:Wood Frame 73 0.310 0.320 23 23 SHGC:0.3 Wall 1:Wood Frame, 122 15.0 0.0 0.077 0.060 9 7 16"o.c. Compliance. Passes using UA trade-off' Compliance: 1.2%Better Than Code Max UA: Your UA: Max SHGC: i 0. The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Compliance Statement The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. $ S( °FI� ,A I D. ZO . ZoZS� Na e - Title Sig ure Date Inspection Checklist Energy Code:2018 IECC Requirements: 97%were addressed directly in the RESCheCk software Text in the"Comments/Assumptions"column is provided by the user in the REScheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented,or that an exception is being claimed.Where compliance is itemized in a separate table,a reference to that table is provided. Pre-Inspection/Plan Review Section Plans Field # Verified Verified & Req.ID Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions 103.1, Construction drawings and Q Complies 103.2 documentation demonstrate [PR111 energy code compliance for the Does Not building envelope.Thermal i Comply envelope represented on Not construction documents. I Observable Not Applicable 103.1, Construction drawings and I Complies 103.2, documentation demonstrate i 403.7 energy code compliance for [�Does Not [PR3]1 lighting and mechanical omply systems.Systems serving i ❑Not multiple dwelling units must Ogservable demonstrate compliance with the IECC Commercial Provisions. Q Not Applicable 302.1, Heating and cooling equipment Heating: Heating: Complies 403.7 is sized per AC( Manual S Btu/hr Btu/hr [PR2]2 based on loads calculated per 0Does Not ACCA Manual I or other methods Comply approved by the code official. Cooling: Cooling: [�Not Btu/hr Btu/hr O servable Q Not applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 1 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Foundation Inspection Section &Req.ID Foundation Inspection Complies? Comments/Assumptions 303.2.1 A protective covering is installed to Complies [F011]2 protect exposed exterior insulation and extends a minimum of 6 in. below O Does Not grade. Comply Not servable PNot licable 403.9 Snow-and ice-melting system controls 0 Complies [FO12]2 installed. Does Not Comply Not serva ble O Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Framing / Rough-In Inspection Section Plans Field # Framing/Rough-In Verified Verified & Req.ID Inspection Value Value Complies? Comments/Assumptions 402.1.1, Glazing U-factor(area-weighted U U Complies See the Envelope 402.3.1, average). � Assemblies table for 402.3.3, Does Not values 402.5 Comply [FR2]1 Not servable 0 Not Applicable 402.4.1.1 Air barrier and thermal barrier Complies [FR23]1 installed per manufacturer's instructions. Q Does Not C mply Not j O Not P Not Applicable 402.4.3 Fenestration that is not site built #" 0 Complies [FR20]1 is listed and labeled as meeting AAMA/WDMA/CSA i 0 Does Not 101/I.S.2/A440 or has infiltration Comply rates per NFRC 400 that do not Not exceed code limits. i 9servable '. Not Applicable 402.4.5 IC-rated recessed lighting 0 Complies [FR16]2 fixtures sealed at housing/interior finish and i Does Not labeled to indicate:52.0 cfm i omply leakage at 75 Pa. I Not Observable PNot plicable 403.3.1 Supply and return ducts in attics Complies [FR12]1 insulated>=R-8 where duct is I >=3 inches in diameter and ComplyD Does Not >= R-6 where<3 inches, a Supply and return ducts in other Not portions of the building servable insulated >= R-6 for diameter >=3 inches and R-4.2 for<3 0 Not inches in diameter. Applicable I 403.3.2 Ducts, air handlers and filter 0 Complies [FR13]1 boxes are sealed with joints/seams compliant with Does Not International Mechanical Code omply or International Residential (�Not Code,as applicable. O servable 0 Not Applicable 403.3.5 Building cavities are not used as Complies [FR15]3 ducts or plenums. , Does Not Comply Not O servable 0 Not Applicable E 403.4 HVAC piping conveying fluids R(� R OComplies [FR17]2 above 105-F or chilled fluids 11 [� below 55°F are insulated to?R- Does Not 3 omply o Not Observable Not pplicable Section Plans Field # Framing/Rough-In Verified Verified & Req.iD Inspection Value Value Complies? Comments/Assumptions 403.4.1 Protection of insulation on HVAC O Complies [FR2411 piping. O Does Not Comply ( qNot O servable Not Applicable 403.5.3 Hot water pipes are insulated to R( 1 R= 0 Complies [FR1812 �R-3• I l Does Not Comply Not servable O Not Applicable 403.6 Automatic or gravity dampers , Complies [FR19]2 are installed on all outdoor air Does Not intakes and exhausts. omply (�Not Ogservable PNot plicable 303.1.3 U-factors of fenestration Q Complies [FR4]1 products are determined in accordance with the NFRC test Does Not procedure or taken from the Comply default table. Not servable Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Insulation Inspection Section Plans Field # Verified Verified & Req.ID Insulation Inspection Value Value Complies? Comments/Assumptions 303.1 All installed insulation is labeled ! Complies [IN13]2 or the installed R-values Does Not provided. omply I _ Not servable O Not j Applicable 402.1.1, Floor insulation R-value. R i R Complies See the Envelope 402.2.6 Assemblies table for [IN1]1 O Wood ❑ Imply Wood Does Not values O Steel Steel Not Observable Not pplicable 303.2, Floor insulation installed per $ Complies 402.2.8 manufacturer's instructions and Does Not [IN2]1 in substantial contact with the I Comply underside of the subfloor,or i om y floor framing cavity insulation is Not in contact with the top side of I servable sheathing, or continuous insulation is installed on the ( Not underside of floor framing and pplicable extends from the bottom to the f top of all perimeter floor framing members. 402.1.1, Wall insulation R-value. If this is Complies See the Envelope 402.2.5, a mass wall with at least'/z of R R Assemblies table for 402.2.6 the wall insulation on the wall O Wood Wood Q Does Not values [IN3]1 exterior,the exterior insulation Comply requirement applies(FR10). Q Mass D Mass ❑Not O Steel O Steel Observable O Not Applicable 303.2 Wall insulation is installed per j Complies [IN4]1 manufacturer's instructions. Does Not Imply qNot servable i Not pplicable Additional Comments/Assumptions: 1 1 High Impact(Tier 1) 1 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Final Inspection Provisions Section Plans Field # Verified Verified & Req.ID Final Inspection Provisions Value Value Complies? Comments/Assumptions 402.1.1, Ceiling insulation R-value. J l R( R= Complies See the Envelope 402.2.1, l s Not Assemblies table for Doe 402.2.2, 0 Wood Wood Comply De values 402.2.E [Fill' 0 Steel 0 Steel Q Not Observable 0 Not Applicable 303.1.1.1, Ceiling insulation installed per 0 Complies 303.2 manufacturer's instructions. [FI21' Blown insulation marked every Does Not 300 ft2. Imply Q Not Observable Ppp Not 1 licable 403.1.2 Heat pump thermostat installed Complies [910]2 on heat pumps. 0 Does Not Comply Not servable 0 Not 1 Applicable 403.5.1 Circulating service hot water I 0 Complies [FI11]2 systems have automatic or accessible manual controls. Does Not omply Not { O servable Q Not Applicable 403.6.1 All mechanical ventilation f' OComplies [FI25]2 system fans not part of tested and listed HVAC equipment I' 0 Does Not meet efficacy and air flow limits Comply per Table R403.6.1. Not servable 0 Not a Applicable 403.2 Hot water boilers supplying heat 0 Complies [FI26]2 through one-or two-pipe heating systems have outdoor Does Not setback control to lower boiler i omply water temperature based on Not outdoor temperature. O servable No t tpplicable 403.5.1.1 Heated water circulation Complies (FI28li systems have a circulation pump:The system return pipe is Does Not a dedicated return pipe or a Comply cold water supply pipe.Gravity I (�Not and thermos-syphon circulation I O servable systems are not present. Controls for circulating hot 0 Not water system pumps start the Applicable pump with signal for hot water demand within the occupancy. Controls automatically turn off { the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems ( Complies [FI29]2 comply with IEEE 515.1 or UL 515.Controls automatically i O rpoi s Not adjust the energy input to the Comply heat tracing to maintain the # , []Not desired water temperature in i Observable the piping. ! 0 Not Applicable Section Plans Field # Verified Verified & Req.ID Final Inspection Provisions Value Value Complies? Comments/Assumptions 403.5.2 Demand recirculation water O Complies [F130]2 systems have controls that Does Not manage operation of the pump and limit the temperature of the amply water entering the cold water ❑Not piping to<= 1049F. Observable PA Not 1 Pp 403.5.4 Drain water heat recovery units ' Complies [FI31]2 tested in accordance with CSA Does Not B55.1. Potable water-side pressure loss of drain water Imply heat recovery units< 3 psi for (❑�Not individual units connected to „ Observable one or two showers. Potable water-side pressure loss of drain Not water heat recovery units<2 Applicable psi for individual units connected to three or more showers. 404.1 90%or more of permanent Complies [FI6]1 fixtures have high efficacy 1 lamps, i Q Does Not I P omply Not servable Not Applicable 404.1.1 Fuel gas lighting systems have ( Q Complies Exception: Requirement [FI23]3 no continuous pilot light. O Does Not is not applicable. Comply Q Not OOservable Not Applicable 401.3 Compliance certificate posted. I Complies [FI7]2 lI Does Not i Comply i Not Observable I E)Not Applicable 303.3 Manufacturer manuals for ! Complies [FI18]3 mechanical and water heating systems have been provided. Does Not Comply Not O servable Not I�pplicable 402.2.3 Vented attics with air permeable Complies [F[22]2 insulation include baffle Does Not adjacent to soffit and eave vents that extends over I Comply insulation. 1 Not ❑ Uservable 1 Not l Applicable 402.2.4 Attic access hatch and door Complies [F13]1 insulation>_R-value of the R� R� adjacent assembly. Does Not omply Not O servable Not pplicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50= ACH 50= O Complies [FI17]1 ach in Climate Zones and O Does Not <=3 ach in Climate Zones 3-8. Comply Not servable Not Applicable Section Plans Field . # Verified Verified & Req.ID Final Inspection Provisions Value Value Complies? Comments/Assumptions 403.3.3 Ducts are pressure tested to Cj Complies [FI2711 determine air leakage with either: Rough-in test:Total cfm/100 ft2 cfm/100 ft2 []Does Not leakage measured with a Comply pressure differential of 0.1 inch (Q�Not w.g.across the system including Ogservable the manufacturer's air handler enclosure if installed at time of Not test. Postconstruction test:Total pplicable leakage measured with a pressure differential of 0.1 inch w.g.across the entire system including the manufacturer's air handler enclosure. 403.3.4 Duct tightness test result of Complies [FI411 <=4 cfm/100 ft2 across the Does Not system or<=3 cfm/100 ft2 cfm/100 ft2 cfm/100 ft2 without air handler @ 25 Pa. For Imply rough-in tests,verification may Not need to occur during Framing servable Inspection, Q Not Applicable 403.3.2.1 Air handler leakage desi nated I Complies [FI2411 by manufacturer at<=2"6/0 of i design air flow. 0 Does Not Comply I Q Not Observable I PPA Not p i 403.1.1 Programmable thermostats Complies [Flg]2 installed for control of primary heating and cooling systems ; Does Not and initially set by manufacturer i Comply to code specifications. ❑Not Observable 0 Not Applicable i Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) 2018 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 0.00 Floor 30.00 Ceiling/Roof 30.00 Ductwork(unconditioned spaces): Glass & Door Rating U-Factor S'HGC Window 0.31 0.30 Door 0.00 Skylight 0.00 Heating & Cooliing Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments: RD0,d 6ENERAL NOTE5 APPROVED AS NOTED i THEL DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY T,,, � �j THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECTS SERVICE,AND ARE AND SHALL I THE ARCHITECT SHALL ASSIST THE OWNER IN FILING AND OBTAINING ALL LOCAL BUILDING DEPARTMENT E ENCDA II C.�.�"B•P . 525REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE APPROVALS FOR THE CON5TRUGTION DOCUMENTS OF THI5 PROJECT. ALL FEES RELATED TO THIS B . INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER APPROVAL PROGE55 SHALL BE PAID FOR BY THE OWNER. UPON BUILDING DEPARTMENT APPROVAL, ANDCNI FEE1�3a�.�o Bt LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE PROCURING A BUILDING PERMIT, THE 6ENERAL CONTRACTOR 15 NOW RE5PON51BL.E FOR THE TAKING OUTLM ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL AND PAYMENT FOR ANY ADDITIONAL PERMITS AND/OR RELATED FEES REQUIRED TO SUCGESSFULLY NOTIFY BUILDING DEPARTMENT AT COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. COMPLETE THE PROJECT UNTIL THE "GERTIFIGATE OF OCCUPANCY" 15 SECURED. 631-765-1802 8AM TO 4PM FOR THE 2 CONTRACTOR SHALL PERFORM ALL WORK IN COMPLIANCE WITH ALL APPLICABLE CODES, CODE FOLLOWING INSPECTIONS: IT IS A VIOLATION THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I AMENDMENTS, STANDARDS, RULE5 AND REGULATIONS INGLUDIN6, BUT NOT LIMITED TO THE FOLLOWING:•. FOUNDATION-TWO REQUIRED ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING LOGAL ZONING ORDINANGES7100 NHAZ MARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION'ALTERED BY" -"'6' N T1 OAD THE NEW YORK STATE RE 51DENITIAL CODE - 2020 EDITION ELECTRICAL. FOR POURED CONCRETE FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE LOCAL BUILDING DEPARTMENT (REQUIREMENTS INSPECTION REQUIRED ROUGH-FRAMING&PLUMBING SPECIFIC DESCRIPTION OF THE ALTERATION. EC PER THE NEW YORK STATE EDUCATION WOOD FRAME: CON5TRUGTION HANUAL FOR ONE AND TWO FAMILY DWELLINGS (2018 EDITION) INSULATION LAW ARTICLE 147 ARCHITECTURE,SECTION 7307) 3 THE CONTRACTOR 15 RESPONSIBLE FOR "METHODS AND MEANS OF GON5TRUGTION". �, FINAL-CONSTRUCTION MUST Fire separation BE COMPLETE FOR C.O. ISSUANCE: 4 CON5HORIINN6GTOR AND BRALL NO% ASIDE, AND BE REQUIRED FOR 5A EE FR, ALL NECE55ARY CUTCnOGUh NY 1 1935 IN5TALLLATION OF H 5 WORK. ' �'equired as per N0. DATE: DESCRIPTION: _�- ALL CONSTRUCTION SHALL MEET THE NYS Code REQUIREMENTS OF THE CODES OF NEW 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING 5 SHOULD UNFORESEEN CONDITIONS OR OTHER GAU5E5 NEGE551TATE GON5TRUGTION DETAILS NOT IN ACCORDANCE WITH THESE PLANS, CONTRACTOR SHALL NOTIFY THE PROPER AUTHORITIES AND SUBMIT HIS 01; TIONEDETAILS SHOWING THE PROPOSED (METHOD TO AGGOMPLISH THE REQUIRED RESULT. N�"5 `2`� DESIGN OR CONSTRUCTION ERRORS 6 WHEN OWNER/CON.TRAGTOR 516N CONTRACT, THE AIA GENERAL GONDITION5 FORM A201 SHALL GOVERN. ry �oT COMPLY WITH ALL CODES OF NEW YORK STATE&TOWN CODES 7 NO NOTE OR LACK THEREOF SHALL- BE GONSTRUED A5 RELIEVING THE CONTRACTOR FROM THE EXECUTION 0 �� OF ALL WORK IN AGGORDANGE WI1TH ALL STATE AND/OR LOCAL GORES. '��w 3� f4S AEQ�IRED AND CONDITIONS 0 S $3 8 THE CONTRACTOR 15 NOT TO 5GALlE DRAWIN6(5) AND 15 TO U5E DIMEN51ONAL NOTATIONS ONLY. .._,.S4UTflOLDTOt IZBA y o Cy�/k 60W,0LDT0V.T.I PLMNIING BOAR q THE 6ENERAL CONTRACTOR AND AtLL 9UBG0NTRAGTOR5 SHALL VI51T THE 51TE AND VERIFY ALL 0IMEN51ON5 .....,,,,.MR.OLDTOY,';'�TRUSTEES AND JOB CONDITIONS PRIOR TO GCON5TRUGTION AND SHALL REPORT TO THE ARCHITECT FOR RESOLUTION V Cy 0 p PRIOR TO GOMMETIGEMENT OF NoRK ANY D15CREPANGIE:5 OR OMISSIONS WHIGH WOULD INTERFERE WITH THE Tft1 / ��W I•■,,._.."I'-YS.DEC - . '' - v k� FF FF�� St�1TF6OLDFif'u SATISFACTORY ..UMPLETION OF THE WORK. y �'I< ._'•'T � ,�' , �� � .. � � � T 3, F 10 THE GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY ERRORS OR AMBIGUITIES IN AND � � A,O OOL p��.� � FE. I'-3"!E � HD BETWEEN THE PLAN5, DRAWINGS AND 5PECIFIGATION5 PRIOR TO PROGEEDING WITH THAT PORTION OF THE !n N QUIP.El \'A WORK. IF 5UGH NOTICE 15 NOT FIJIRN15HED TO THE ARCHITECT, THE CONTRACTOR SHALL BE DEEMED TO HAVE �11 12' 0 PLU 4BING INSPECTED THE PLAN5, DRAWINGS„ SPEGIFIGATION5 AND HA5 FOUND THEM IN PROPER FORM FOR EXECUTION. Compliance Certificate ry v� '� EXIST. VINYL SHED RLL P'LU 31NG WASTE PLUMBER CERTIFICATION 11 CONTRACTOR TO PROVIDE ALL NEGE55ARY BARRICADES, 6UARD5, WARNING LIGHTS, 516N5, ETC., TO INSURE -C.�3" 14� 7" &WATER -INES NEED ON LEAD CONTENT BEFORE MIN. REQ'D. REAR TESTING BE )RECOVERING CERTIFICATE OF OCCUPANCY THE 5AFETY OF 17HE WORK AREA. Project Information 12 CONTRACTOR SHALL PROVIDE ALL MATERIALS, PERFORM ALL WORK AND INSTALL ALL MATERIALS IN YARD SETBACK O' SOLDER USED IN WATER ACCORDANCE WITH RECOGNIZED GOOD STANDARD PRACTICE. CONTRACTOR IS RE5PON51BLE FOR Project Title: McNeill Residence U TRUSS PU.ICA. ).'"IG REQU1'tED SUPPLY SYSTEM CANNOT INFORMATION THAT PERTAINS 50LELY TO THE FABRIGATION5 PROCESS OR THE TEGHNIO UE5 OF Energy Code: 2018 IECC u Q 0 �r z — EXCEED 2110 OF 1% LEAD. CON5TRUCTION AND FOR COORDINATION OF THE WORK OF ALL TRADES. Location: Cutchogue,New York O E- �-0 O (� I Ld M 13 ALL DISTURBED ,4REA5 TO BE REPAIRED IN KIND BY GENERAL CONTRACTOR. Construction Type: Single Family z ti J Project Type: Addition RELOCATED A/C UNIT O / o O O RETAIN STORM WATER RUNOFF Project Sub Type: None (COORD. IN FIELD) - o fY W_ O PURSUANT TO CHAPTER 236 . 14 MINOR ITEMS 5UGH AS PATCHING, E3LOGKIN6, TRIM, ETC. SHALL BE PERFORMED A5 REQUIRED !L TO MAKE THE WORK COMPLETE WHETHER SHOWN OR NOTED ON THE DOGUMENT5 OR NOT. Glazing Area: 9% REPLACE PVG TRASH/ '� W M / W LU z Y m OF THE TOWN CODE Climate Zone: 4a(5572 HDD) AG ENCLOSURE p — Z 15 CONTRACTOR SHALL MAINTAIN THE= 51TE IN A 5AFE, GLEAN AND ORDERLY FASHION FOR THE DURATION OF All Electric: false (GOORD. IN FIELD) 2 / J THE CON5TRUGTION PERIOD. ALL t'MATERIAL (GONCRETE, FILL, WOOD, ETC AND CONSTRUCTION DEBRI5 TO Is Renewable: false BE REMOVED AT THE END OF EAGf-1 WORK DAY AND SHALL BE DI5PO5ED OF RE6ULARLY AT A LEGAL OFF Has Battery: false MODIFY STEPPING STONE 4 ® G 20' Mechanical Ventilation 51TE WASTE FACILITY. BEL6IUM BLOCK TRASH/ AG v / "F LO No. 346 LOT No. 345 rystem shall be required • Has Charger: false Has Heat Pump false ACCESS AS REQ'D. BY NEW WORK SINGLE HATCH INDICATES AREA OF EST per NYS Energy Code 16 THE CONTRACTOR SHALL BE RE5PeON51BLE FOR ANY DAMAGE INCURRED ANYWHERE WITHIN THE / z BOUNDARIES OF THE PROPERTY AMD ANY DAMAGE SHALL BE PROMPTLY REPAIRED TO THE 5ATI5FAGTION 17- NAL FLOOR INTERIOR ALTERATION (345 5.F) OF THE ARCHITECT AND OWNER. = Provide windbornA d�brl� construction site: owner/Agent: Designer/contractor: LOT No. 34-1 EXIST. v DOUBLE HATCH INDICATES AREA OF 2ND 1-1 NOTATIONS ON ANY PLAN, El EVATIION, 5EGTION OR DETAIL ARE APPLICABLE TO 710 Old Menhaden Road Dan&Sophie McNeill Stephen Scheibly _ COMPOSITE EXIST. FLOOR INTERIOR ALTERATION (345 S.F) Protect!on for nE.'L'"!c2;tC:"o" ALL PLAN5, ELEVATIONS, 5ECTION5 AND DETAILS. Cutchogue,NY 11935 710 Old Menhaden Road 255 Main Street r DECK BRIGKI �, ��Q,.i , �IL€'"1Ct5 cS��. Cutchogue,NY 11935 Diversified Design Associates,Architects P.C. _ HT. O 8 PAT( XIST. 2nd STY. �'�' " �• +44(755)594-7734 Huntington, NY 11743 k BALCONY TO BE RENOVATED P��YS CQ�^.a IS PROVIDE 1/2" W.R. 6YP5(JM WALL BOARD ALL WALLS/GEILIN65 OF "WET" AREA5 sophie.mcneill@hotmail.com 631.271.5400 x 102 ?O,4 0�9 _N OVER PORCH TO REMAIN (SHOWERS, TUBS, ETC) y l0 STRUCTURAL KUROS SORB(-OVA ENGINEERING sscheibl @ddanynet 3-�' t y ` ENGINEER: 169 COMMACK ROAD .< SUITE H-362 Iq ALL NEW APPLIANCES ARE AS SEL OWNER ECTED BY AND SHALL BE INSTALLED l ' %'' ;' : `X; 'J�: q'-1O" FE. O I ±E. COMMACK NY 11725 BY THE CONTRACTOR AS PER THIS MANUFAGTURER5 5PEGIFIGATION5. Envelope Assemblies O; ;No:.x?10,: ;:;, 6 Oil 2 `� STORY.:;. =r GATE 631-355-5556 20 ALL INTERIOR HOOD TRIM/BASE ShHALL BE AS SELECTED BY OWNER Prop. Req. q FRAME,`, AND INSTALLED BY THE GENERAL IGONTRAGTOR. Assembly Gross Area or Cavity Cont. U- U- Prop. Req. /�DWELL1NG,:_ m y Perimeter R-Value R-Value Factor/ Factor/ UA UA HATCH INDICATES AREA OF FIRST FLOOR 21 TYPE/LOGATION/I=XTENT OF ALL NEW INTERIOR FINISHES (PAINT, CERAMIC TILE, F-Factor F-Factor ' 3 FF.. 0'-q"±W. VINYL TILE, CARPET, ETC) SHALL BE AS 5ELEGTED/DIRECTED BY OWNER. GARAGE ADDITION (117.74 5F) Ceiling: Fiat Ceiling or 294 30.0 0.0 0.035 0.026 10 8 - IL t: � ScissorTruss 27 4 I I 22 ALL ELECTRICAL., PLUMBING AND H.V.A.C. TO BE IN STRICT ACCORDANCE WITH THE 1. DOUBLE HATCH INDICATES AREA OF _ Floor:All-Wood 261 30.0 0.0 0.033 0.047 9 12 � < INTERNATIONAL FESIDENTIAL CODEAND ALL APPLICABLE LOCAL REGULATIONS. joist/Truss GARAGE CONVERTED TO HABITABLE CV SPACE (178.47 5.F) / 14'-6 4 ? r ` R/O WOOD PORG FE. O'-q"±11 � Wall:Wood Frame,16" 673 21.0 0.0 0.057 0.060 34 36 _ , n r 23 INSTALL SMOKE DETEGTOR5 AND (CARBON MONOXIDE DETECTORS IN ACCORDANCE E O.C. SOLID HATCH INDICATES AREA OF WITH ALL STATE AND LOCAL GODIE REQUIREMENTS. Window:Wood Frame 73 0.310 0.320 23 23 SECOND FLOOR ADDITION (222 5.F) Y SHGC:0.3 MODIFY PLANTING BED AS DIRECTED _MODIFY, REPAIR 4 REPLACE EXISTING DECK, 24 PRIVATE 6ARA6E 5HA1_L BE 5EPARATED HORIZONTALLY AND VERTICALLY FROM Wall 1:Wood Frame, 122 15.0 0.0 0.077 0.060 9 7 6 WALKWAY STONE LANDSCAPE WALL AS REQ'D. BY NEW WORK THE RE51DENGE WITH NOT LE-55 THAN 3/e TYPE X 6YP5UM BOARD 16"o.c. BY OWNER HATCH INDICATES AREA OF FIRST FLOOR 25 OPENINGS FROM A PRIVATE 6ARAtGE INTO A RESIDENCE SHALL BE EQUIPPED WITH . `f " LAUNDRY ROOM ADDITION (63.25 5F) 15' A 20 MINUTE FIRE RATED DOOR ASSEMBLY WITH A 5ELF-GL051N6 DEVICE. i I _ rr g t ¢ 26 CONTRACTOR TO 5GHEDUL.E AND OBTAIN ALL NEGE55ARY UTILITY 5TAKE OUTS Le. WATER, ELECTRIC:, 5EPTIC'4 6A5 PRIOR TO GOMMENCING WITH ANY 51TE WORK. The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.It DOES Q — _ — � DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. NOT provide an estimate of energy use or cost relative to a minimum-code home. J/I -*v MIN. REQ'D. SIDE O 1U - YARD SETBACK 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in P,EScheck. Each slab-on-grade � V J Z P. 6 31.2 71.54 0 0 WWW.DDANY.NET assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. oO Copyright ©zozs All i M T O O G RA F H I C � 51 G N C 1 TE I A ) p w SEAL: PROJECTryNORTH: Compliance Statement ry Wc�w SUBJECT TO IGE BARRIER FLOOD (Y fL1 (SJ GROUND WIND DESIGN 5EEI5MIG DAMAGE BY WINTER AIR MEAN The proposed building design described here is consistent with the building plans,specifications,and other calculations SNOW DDE516N UNDERLAY- HAZARDS DESIGN MEW FREEZINGANNU submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in Z� ��- LOAD SPEED f,RTAPO- WMa- BOfdE GA VEArclz L T T�2MITE ZONE X INDEX TEMP. REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. < A11 - (tEFFECTS i�oH »MW GIs °�H TEMPRE( 11RED EFFECTIVE MIN. REQ'D. 51DE / z X NI ,in ZI FIRM: YARD SETBACK / O w - m n �� MOD. CXf/25/20Oq 1500 �\ ry T O z O ry - 30 PSF 128 NO NO NO B 3-0 TO 15 YES PANEL #: OORS �'8 Name -Title Signature Date / � �• FE. 0'-104 E. HEAVY 36103W I64 THI5 PROJECT 15 IN COMPLIANCE WITTH: N 112•�8 STACKED STONE WALL PROJECT TITLE: THE RESIDENTIAL CODE OF NEW YORIK STATE - 2020 EDITION ti T 468 ± AFPA WOOD FRAME:. CONSTRUCTION HANUAL FOR ONE AND TWO FAMILY DWELLIN65 - 2018 EDITION O„ V�`� N '74��•4�2�4�� � RENOVATIONS & ALTERATIONS TO THE: THE ENERGY CONSERVATION CODE 01F NEW YORK STATE- 2020 EDITION Report Title: McNeill Residence Report Date: 8/29/25, 11:32 AM 2 of 11 i 5\0Ng THE ZONING GODS OF THE TOWN OF 5OUTHOLD yr N �-(p,G CLI�) �,HA� NMcNEILL RESIDENCE NFPA70 STANDARD - 201-1 EDITION 2; ROAat;) NATIONAL ELECTRICAL GODE 201-751TE PLAN( J I C�5 M5® L 6 I �� L15T O� RANII �67 I A CHITE0TV Aice. 5IT� FLAN SURVEYOR5N INFORMATION NY AND ATED MAY 25, 2025 FROM 50RVEY PREPARED BY 151AND WIDE LAND 710 OLD MENHADEN ROAD GS-I SITE PLAN, GENERAL NOTE5, RESGHECK COMPLIANCE CERTIFICATE CS 5 G A L E : 1 " = 2 0 ' - 0 " CUTCHOGUE , NEW YORK 11935 SYMBOL DESCRIPTION SYMBOL DE-5GRIPTION SYMBOL DESGRIPTION A-001 6RO55 FLOOR AREA DIAGRAMS, LOT COVERAGE DIAGRAM }� I DRAWING TITLE: A-100 GENERAL NOTES, PLUMBING RI5ER DIAGRAM, PLUMBING FIXTURE 5GHEDULE, REQUIRED 516N POSTINCa ZO I`I I NG INFORMATION GENERAL NOTES x A-101 FIRST FLOOR DEMOLITION PLAN, NOTES AND DETAILS PROPERTY ADDRE55: 710 OLD MENHADEN ROAD TAX MAP NO. 5EGT. II I BLOCK 4 LOT Iq L 15T OF DRAM I N65 SECTION REFERENCE DOOR REFERENCE x-x 5EE DWG. A5 NOTED X EL-EVATION TAG 5EE OX -5EE DOOR A-102 SECOND FLOOR DEMOLITION PLAN, NOTES AND DETAILS CUTCHOC-UE, NY IN35 PROPERTY ZONING: ZONE R-40 ARCHITECTURAL SITE PLAN DW6. A5 NOTED SCHEDULE A-103 FOUNDATION PLAN, NOTES AND DETAILS ITEM PERMITTED/ REOU I RED PROVIDED COMPLIANCE RESCHECK COMPLIANCE CERT. A-104 FIRST FLOOR CONSTRUCTION PLAN, NOTES AND DETAILS MINIMUM LOT AREA 40000 5•F• 14,316.33 5.F. * DOES NOT COMPLY DETAIL REFERENCE- NOTE REFERENCE- 5EE WINDOW REFERENCE x 5EE DWG. A5 NOTED XXX NOTE I E6EN0 FOR O - SEE WINDOW A-105 SECOND FLOOR CONSTRUCTION PLAN, NOTES AND DETAILS MINIMUM LOT WIDTH 150 FEET qq'-7" * DOES NOT COMPLY X-X ADD'TL INFO. 5GHEDULE A_106 ROOF PLAN, NOTE5 AND DETAILS, ROOF VENT DETAIL MINIMUM LOT DEPTH 175 FEET 225.82' COMPLIES ELEVATION NA-L TYPE REVISION A-107 SECOND FLOOR FRAMING PLAN, NOTES AND DETAILS MINIMUM FRONT YARD SETBACK 50 FEET " -lb'-4Y2 COMPLIES DRAWN BY: SDE SHEET N0. BENCHMARK XX REFERENCE - 5EE Ax TAG A-105 ROOF FRAMING PLAN NOTES AND DETAILS MINIMUM SIDE YARD SETBACK 15 FEET q'-10" * DOES NOT COMPLY f WALL TYPE5 A-200 EXTERIOR ELEVATIONS MINIMUM SIDE YARD A66RE6ATE 35 FEET 30'-2 CHECKED BY: 3/4" * DOES NOT COMPLY ROOM FURNITURE / EQUIPMENT PLUMBING FIXTURE A-201 EXTERIOR ELEVATIONS MINIMUM REAR YARD SETBACK 50 FEETAdMk 101 RECE 80 1 Y4 GOMPLIE5 DATE: 10.20.25 NUMBER RE N - 5EE SCHEDULE OX REFERENGE-5EE A-500 CRO55 SECTION, MODIFIED BIRDS MOUTH DETAIL MAXIMUM LOT GOVERA6E 20% (3,863.27 5.F) 18.5 5� (3,377.1 S.F.) GOMPLiES TAG SCALE: A5 NOTED PLUMBING FIXTURE A-400 STRAPPING DETAILS MAXIMUM 6RO55 FLOOR AREA 2,100 S.F. + (12.5% OF 61,316.33) = 3,264.54 S.F. 3,2 A3 S.F. GOMPLIES C5 SCHEDULE A-401 NAILING SCHEDULE MAXIMUM BUILDING HEIGHT 2 STORIES OR 35 FEET 2 5TORIE5; 31'-7" COMPLIES PROJECT NO. 2515 E-100 FIRST FLOOR LIGHTING PLAN NOTE: THI5 PROPERTY 15 AN EXI5TIN6 NON-GONFORMIN6 LOT * = EXISTING NON CONFORMING SECOND FLOOR LIGHTING PLAN �.��: :':°7,'�4 E 101 NOTE: 5EE A-001 FOR FLOOR AREA AND LOT COVERAGE DIA6RAM5 3 i 4 i LOT COVERAGE CALCULATION: GROSS FLOOR AREA CALCULATION: THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY PERMITTED LOT GOVERAGE = 20% LOT AREA THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE,AND ARE AND SHALL 30'-2 5/8" f LOT AREA = Ig,316.33 5.F. LOT AREA = Iq,316.33 5F REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE Iq,316.33 5F x 20 % = 3,86321 5.F. PERMITTED INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER GR055 FLOOR AREA (LOTS UP TO 20p00 S.FJ LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE ALLOWABLE: 2,100 5.F. + 12.5% OF LOT AREA IN EXCESS OF 10,000 5.F. EXISTING LOT COVERAGE AREAS: ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL 2,100 5.F. + (12.5% OF q,316.33) - 3,26454 5.F. � � COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. EXISTING TWO STORY DWELLING (INCLUDING GARAGE) = 1,615.36 5.F. IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION FIRST FLOOR: EXISTING R.O. PORCH #1 = 428.16 S.F. OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I AREA A = 14'-5" x 28'-5 3/e"= 410.12 5F EXISTING R.O. PORCH #2 = 66.35 5.F. ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING EXISTING DECK = 251.g6 5.F. ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION'ALTERED BY" I5TING VINYL SHED EXI5TING VINYL SHED = 101.31 S.F. FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE AREA B = 21'-4 �/g" X 22'-1 5/8"= 61 q.88 5F SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION AREA C = 30'-2 5/g' X 16'-I I Y8" = 51152 5F 13 101.31 5F EXI5TING 5WIMMING POOL = 1g2.85 5.F. AREA "I" AREA D = 8'-4 Ye," x -i'- 3 5/8" = 6OA3 5F EA5TI% 5TAGKED STONE WALL #1 = '7 31 5.F. LAW ARTICLE 147 ARCHITECTURE,SECTION 7307) AREA E = 6-0,Y2" x 5-1 I Y4" = 35.81 5F EXI511% STACKED 5TONE WALL #2 = 41.8 5.F. AREA F = 10-1 x 3-6 31.04 5F ISSUANCE: FIRST FLOOR EXISTING TOTAL = Ib15.36 5F TOTAL EXISTING LOT COVERAGE AREA = 3.311.1 5.F. NO. DATE: DESCRIPTION: SECOND FLOOR: I PROP05ED LOT GOVERAGE AREA5: 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING AREA G = 22'-6 3/4" x 28'-6 %8" = 644.68 5F PROP05ED GARAGE ADDITION = 111.14 5.F. AREA "H" AREA H = 13'-8 Y2" x 6-2 '/8" = 181.4q 5F PROP05ED LAUNDRY ADDITION = 83.25 5.F. AREA 1 = 30'-2 5/8' x 11'-O" = 332.41 5F TOTAL PROP05ED LOT GOVERAGE AREA = 200.gg 5.F. m � � 5ECOND FLOOR EXISTING TOTAL = 1.158.58 5F = AREA "G'" TOTAL LOT COVERAGE AREA= 3 18.Oq 5.F. < 3,863.21 5.F. COMPLIES r O AREA "Lrr EXISTING GRO55 FLOOR AREA TOTAL = 2,833.g4 5F EXISTING LOT COVERAGE 18.5 < 20 (COMPLIES) PAVER PATIO EXI5T1% 5WIMMIN6 (Z MOP05ED FIR5T FLOOR ADDITION5: (® GRADE) POOL 1g2.85 5F AREA J = 14'-5" x 8'-2" = 111.14 5F AREA K = 13'-10 Y2" x 6'-0" = 53.25 5F / FIRST FLOOR ADDITION5 TOTAL = 200.gg 5F PROP05ED SECOND FLOOR ADDITION: EXI5TIN6 DECK 251.g6 5F AREA L = 13'-10 Y2" x I6-0" = 222.0 5F L PROP05ED ADDITIONS TOTAL = 422.gg 5F 13'-10 1/2" 22'-6 5/4" 13'-8 1/2" TOTAL PROP05ED 6RO55 FLOOR AREA= 3.256.,,13 5.F. EXI5TIN(5 BRICK PATIO 15TING R.O. PORCH#2 3256A3 < 3264.54 5.F. (GOMPLIE5) PROPOSED LAUNDRY ADDITION (® GRADE) 66.35 5F SECOND FLOOR AREA DIAGRAM 8325 5F 13'-10 1/2" 30'-2 5/8" 6-0 1/2" 10'-1" I I m AREA "F" EXISTING TWO STORY DWELLING PROP05ED GARAGE 1,615.36 5F ADDITION 111.14 5F STRUCTURAL KUROS SORBI-AVA ENGINEERING ENGINEER: 169 COMMACK ROAD - EXISTING R.O. PORCH #I SUITE H-362 COMMACK, NY 11725 AREA "Go 428.16 SF 631-355-5556 zt AREA "K" AREA "Ell I 6J AREA rrDrr t- EXISTING DRIVEWAY ( (Z AREA 111311I ..,.:; . u� AREA "A" (Z DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 P. 631.271 .54 00 WWW.DDANY.NET Copyright 02025 All Rights Reserved. SEAL: PROJECT NORTH: EXI5TIN6 5TAGKED 15TIN6 STACKED STONE WALL #1 ( 5TONE WALL #2 1.31 5F 41.5 5F AREA "J° 14'-5" 21'-4 5/8" 8'-4 1/8" PROJECT TITLE: RENOVATIONS & ALTERATIONS TO THE: FIRST FLOOR AREA DIAGRAM McNEILL RESIDENCE 1 f=LCOR AREA 1:) 1A6RAM5 HATCH INDICATE-5 PROPOSED AREA 2 L07 CCVERA&E Z� I A6RAM 710 OLD MENHADEN ROAD A001 1/8" = I'-o" A001 me- = I'-o" CUTCHOGUE , NEW YORK 11935 DRAWING TITLE: FLOOR AREA D I A ORAMS LOT GOV ERA &E D I A &RAM DRAWN BY: 50E SHEET NO. CHECKED BY: SJS DATE: 10.20.25 A=001 SCALE: A5 NOTED PROJECT NO. 2515 77 77 m; S 1 TE WORK FRAM I NG - CONSTRUCTION LUMBER A I R BARRIER AND INSULATION INSTALLATION 6"0 516N W/ STROKE WIDTH OF Y2" CIRCLE SIGNS MAY BE PURCHASED AT 1. STAKEOUT 15 TO BE PERFORMED BY A LICENSED SURVEYOR. 5TAKING AND LAYOUT I FRAMING LUMBER SHALL BE SQUARE-EDGE, 5TRAIGHT, SOUND, WELL-SEASONED, WITH A [� To TABLE R402.4.1.1 of THE RESIDENTIAL GORE of NEW PORK sTATEI AND CONTENTS ARE TO BE REFLECTIVE WWW.5AFE-T-50LUTION5.00M OR THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED L ARE TO E5TABLI5H ALL LINE5 AND BENCHMARKS AND VERIFY ALL 61VEN DATA ON RED COLOR PM5 #157, BAGK6ROUND TO WWW.5TIGKY56RAPHIG5.COM OR SIMILAR SITE. THE ARCHITECT ARE INSTRUMENTS C THE ARCHITECT'S SERVICE,AND ARE AND SHALL MAXIMUM MOISTURE CONTENT OF NINETEEN (IgSG) PERCENT AT THE TIME OF INSULATION INSTALLATION REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE DRAWINGS. IN CASE OF DI5GREPANGY, RECEIVE CLARIFICATION FROM ARCHITECT INSTALLATION. LUMBER SHALL BEAR THE GRADE AND TRADEMARKS OF THE GOMPON NT AIR BARRIER CRITERIA CRITERIA BE REFLECTIVE WHITE INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER PRIOR TO PROGEEDIN6. ASSOCIATION BY WHOSE RULES IT 15 PRODUCED, SIZES INDICATED ARE NOMINAL CONSTRUCTION DESIGNATION; SUBJECT TO LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE STANDARD SIZES. GENERAL REQU AIR BARRIER SHALL BE CONSTRUCTION PROVISIONS OF RCNYS ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL INSTALLED IN THE BUILDING ENVELOPE AIR-PERMEABLE INSULATION SHALL NOT BE COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. 2. EXCAVATE AND BACK FILL FOR WORK INDICATED ON DRAWINGS. STOCKPILE 2 FRAMING LUMBER SHALL BE STRESS-RATED DOU6LA5 FIR LARCH NO. 2 WITH A EXTERIOR THERMAL ENVELOPE CONTAINS USED AS A SEALING MATERIAL LOCATION DESIGNATION TOPSOIL OBTAINED FROM STRIPPING BUILDIN6 51TE AND STOCKPILE ALL EXCAVATED 5TRE-55 RATING OF 675 P51 RESPECTIVELY FOR BENDING FOR SINGLE MEMBER USE A CONTINUOUS AIR BARRIER IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION MATERIAL AT THE SITE. AND a0 PSI MINIMUM FOR SHEAR. BREAKS OR JOINT5 I THE AIR BARRIER 5HALL OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I E 5EALED ,k ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING 3• NEW AND EXISTING BACK FILL MATERIAL AND TOP501L ARE TO BE FREE OF WEEDS, 5 PROVIDE DOUBLE FRAMING AROUND ALL OPENINGS, UNDER ALL PARALLEL WALLS AND THE AIR BARRIER IN ANY DROPPED CEILING/ NOTE: 516N 15 TO BE AFFIXED TO EXTERIOR ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION'ALTERED BY" TREE ROOTS, ROCKS AND DEBRIS. UNDER BATHTUBS. PROVIDE 51MP50N HANGER CONNECTIONS AT ALL FLUSH CEILING/ATTIC SOFFIT SHALL ELECTRICAL BOX. 516N 15 TO BE OF STURDY, FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE THE INSULATION IN ANY DROPPED CEILING/ ,J NO FADING, WEATHER RESISTANT MATERIAL. SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION SEALEDSTRUCTURAL LOAD BEARING CONDITIONS. AND ANY GAPS IN THE AIR BARRIER SHALL ALIGNED w/THE INSULATION SOFFIT SHALL BE ALIGNED w/THE AIR - LAW ARTICLE 147-ARCHITECTURE,SECTION 7307) 4. ALL 5URPLU5 MATERIAL THAT 15 UNSUITABLE FOR BACK FILL MATERIAL SHALL BE 4 PROVIDE SOLID BRIDGING BETWEEN JOISTS AT 6'-0" o.c. MAXIMUM. BE BARRIER. REMOVED FROM THE SITE. ACCESS OPENINGS,DROP DOWN STAIRS OR 5 UNLESS OTHERWISE NOTED, ALL WINDOW AND DOOR OPENINGS SHALL HAVE (2) 2" X 10" KNEE HALL DOORS TO AGES SHALL BE SEALED.UNCONDITIONED ATTIC I Q U I � I ON f=05T I NO ISSUANCE: 5. PROTECT ALL TREES WITHIN EIGHT FEET OF THE BUILDING. HEADERS ABOVE. WALLS THE JUNCTION OF HE FOUNDATION AND SILL CAVITIES w/CORNERS AND HEADERS OF NO. DATE: DESCRIPTION: 6. PROPER APPROVAL MUST BE OBTAINED BEFORE COVERING (BACK FILLING) ANY b ALL PLATES IN CONTACT WITH FOUNDATION WALLS TO BE PRESSURE TREATED AND ATE FLED co�MPLETEY FIH IN HALLS NGG THHE BE INSULATED CAAVIITY KITH A A100 3" = I'-O" 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING HAVE CONTINUOUS METAL TERMITE SHIELDS. PLATE5 SHALL BE BOLTED TO THE JUNCTION OF THE TOP PLATE AND THE MATERIAL HAVING A THERMAL RE51STANG EXCAVATED WORK. FOUNDATION WALL5 WITH 5/8" DIAMETER BOLTS AT 48" o.c. MAXIMUM AND 1'-0" TOP OF EXTERIOR WALLS SHALL BE SEALED. OF R-3 PER INCH MINIMUM. MAXIMUM FROM EACH CORNER. BOLTS MUST BE EMBEDDED A MINIMUM OF 7" INTO KNEE WALLS SEALED. EXTERIOR THERMAL ENVELOPE INSULATION 7• CONTRACTOR 15 RES:PO R TO TO CONTACT ALL UTILITY COMPANIES AND REQUEST FOUNDATION WALLS. FORGE MORTAR INTO THE JOINT BETWEEN SILL BOTTOM AND FOR FRAMED WALLS 54ALL BE INSTALLED UTILITY STAKEOUTS PRIOR TO GOMMETIGIN6 WITH EXCAVATION. IN SUBSTANTIAL CONTACT AND CONTINUOUS FLUMBIN6 f= IX7URE CONCRETE AND FOUNDATION TOP OF FOUNDATION. ALIGNMENT WITH THE AIR BARRIER 5CHr=r:)ULE 7 ALL 5lU13-FLOORIN6, WALL AND ROOF SHEATHING SHALL BE EXTERIOR GRADE GDX WINDOWS,SKYL PAGE BETWEEN WINDOW/DOOR JAM65 I. ALL CONCRETE OR MASONRY WORK SHALL BE DONE DURING TEMPERATURES OF 32 PLYWOOD, 511,1113-FLOORIN6 - 3/4", WALL 5HEATHIN6 - 1/2% ROOFING SHEATHING - 5/8". AND DOORS AND FRAMING AND SKYLIGHTS AND FRAMING RE5PON51BLE FOR DE6REE5 FAHRENHEIT AND R151N6 MINIMUM. SHALL BE SEALED TA& FIXTURE LOOAT1 ON SPEC I F I OATI ON PURGHA5E 8 ALL BUILT-UP WOOD GIRDERS AND HEADERS SHALL NOT HAVE ANY SPLIT ON THE RIM J015T5 RIM JOISTS SHALL INCLUDE THE AIR BARRIER RIM JOISTS SHALL BE INSULATED INSTALLATION 2. NO CONCRETE SHALL BE PLACED ON FROZEN SURFACES. WIDE FACE OF ANY MEMBER GREATER THAN 1/2 TIMES THE WIDE FACE. TO BE SELECTED 3. NO ADDITIVES SHALL BE ALLOWED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT. Q ALL EXPOSED WOOD FOR SOFFITS, OVERHAN65, ETC. SHALL BE APPROVED FLOORS THE AIR BARRIER SHALL BE INSTALLED AT FLOOR FRAMING CAVITY INSULATION O LAVATORY 4 RENO BATH #1 7!-CONTRAGTOR EXTERIOR GRADE. (INCLUDING ANY EXPOSED EDGE OF INSULATION BE INSTALLED TO MAINTAIN PERMANENT FAUCETABOVE CONTACT WITH THE UNDERSIDE OF 4• ALL CONCRETE WORK SHALL CONFORM TO REQUIREMENTS AND RECOMMENDATIONS 10 ALL FLUSH FRAMING CONNECTIONS SHALL BE MADE WITH JOIST HANGERS, FRAMING GARAGE 4 5UBFLOOR DECKING,OR FLOOR FRAMING HALL HUN6 TO BE SELECTED OWNER OF AGI-301-G9 "5PECIFIGATION5 FOR STRUCTURAL CONCRETE FOR BUILDIN65" ANCHORS, OR RAFTER ANCHORS OF MINIMUM IS 6AU6E PRIME 6ALVANIZED STEEL AS CANTILEVERED CAVITY INSULATION SHALL BE PERMITTED (fc'=3000 P50. ALL EXPOSED 5LAB5, 6ARA6E SLABS AND STEPS SHALL BE 3500 MANUFACTURED BY "SIMPSON" 5TRONG TIE CONNECTORS. 51ZED AND NAILED AS PER FLOOR5) TO BE IN CONTACT WITH THE TOP 51DE OF 2 TOILET KENO BATH #I CONTRACTOR SHEATHING,OR CONTINUOUS INSULATION PSI AIR-ENTRAINED. REINFORCING STEEL SHALL CONFORM TO A5TM A-615 GRADE 60 REACTIVE LOAD. INSTALLED ON THE UNDERSIDE OF FLOOR SHOWER BASE 4 TO BE SELECTED OWNER O3 II NAILING TO CONFORM TO SCHEDULE INDICATED IN THE W FRAMING AND EXTENDS FROM THE BOTTOM WOOD FRAME CONSTRUCTION TO THE TOP OF ALL PERIMETER FLOOR SHOWER BODY RENO BATH #1 5. PROVIDE ALL SLEEVES AND FOUNDATION VENTS AS REQUIRED BY RESIDENTIAL MANUAL FOR ONE AND TWO FAMILY DWELL IN65 UNLESS OTHERWISE NOTED. FRAMING MEMBERS CONTRACTOR GODS OF N.Y.S. TO BE SELECTED WHERE PROVIDED INSTEAD OF FLOOR O UTILITY SINK 4 OWNER :� 12 LEAVE Me," SPACE AT ALL PLYWOOD PANEL END JOINTS AND 1/8" SPACE AT ALL CRAWL SPACE D EARTH E HITH ED CRAWL SPARES INSULATION, INSULATION SHALL BE `F FAUCET 1"1 LAUNDRY 6• UNLESS OTHERWISE INDICATED, ALL FOUNDATION FOOTING ARE TO BE MINIMUM 12 PANEL EDGE JOINTS. SHALL BE COVERED WITH A GLASS I VAPOR PERMANENTLY ATTACHED TO THE CONTRACTOR DEEP X 24" WIDE, CENTERED UNDER THE FOUNDATION WALL (OR AS PER DETAILS) RETARDER WITH OVERLAPPING JOINTS TAPED PERMANENTLY WALLS O EXISTING TO BE RE-USED 13 PROVIDE SOLID BLOCKING FROM TOP/61RDER OR FOUNDATION WALL TO THE 5 KITCHEN SINK 4 RENOVATED OWNER 7• PROVIDE TWO #5 DEFORMED BARS CONTINUOUS IN THE FOOTING AND A CONTINUOUS UNDERSIDE OF FLOOR AT WOOD POSTS. ALL WOOD P05T5 SHALL BE 4"X4" MINIMUM. SHAFTS, SHAFTS,UTILITY PENETRATIONS,AND FAUCET KITCHEN 2"x4" KEY BETWEEN THE FOOTING AND FOUNDATION WALL EXCEPT A5 NOTED FLUE SHAFTS OPENING To SHALL OR CONTRACTOR UNCONDITIONED SPACES SHALL BE SEALED TO BE SELECTED OTHERWISE. 14 NOTATIONS ON ANY PLAN, ELEVATION, SECTION OR DETAIL ARE APPLICABLE TO ALL BATTS IN NARROW GAVITIE5 SHALL. BE GUT O HOSE BIB EXTERIOR (I AT OWNER PLANS ELEVATIONS 5EGTION5 AND DETAILS. NARROW CAVI FRONT I AT REAR) 8. PROVIDE 5/8" X 12" ANCHOR BOLTS. ALL FOUNDATION WALLS SHALL HAVE ANCHOR TO FIT,OR NARROW CAVITIES SHALL BE CONTRACTOR FILLED BY INSULATION THAT ON BOLTS SET APPROXIMATELY ONE FOOT FROM EACH CORNER AND SPACED 48" ON IS JOISTS ARE NOT TO BE NOTCHED. ALL HOLES FOR PLUMBING MUST BE DONE IN INSTALLATION READILY CONFORMS TO THE O LAVATORY 4 NEW BATH #2 TO BE SELECTED 7!�_ CENTER. THERE SHALL BE ANCHOR BOLT5 ON EITHER SIDE OF ANY OPENING AND AT ACCORDANCE WITH WESTERN WOODS GUIDELINES FOR DIMENSIONAL LUMBER. GARAGE SEPA lFOSEALING SHALL BE PROVIDED BETWEEN AVAILABLE CAVITY SPACE FAUCET LEAST TWO BOLTS IN ANY ONE SILL. THE GARAGE AND CONDITIONED SPACES CONTRACTOR 16 INSTALL FIRE5TOPPIN6 AT ALL REQUIRED LOCATIONS COMPLY WITH GOVERNING TO BE SELECTED RECESSED LIGHT FIXTURES INSTALLED IN WALL HUNG OWNER a. PROVIDE PREMOLDED JOINT FILLER BETWEEN SLABS AND FOUNDATION WALLS. CODES. RECESSED LI ESSED LIGHT FIXTURES INSTALLED IN THE THE BUILDING .THERMAL ENVELOPE SHALL 8 NEW BATH #2 BUILDING THERMAL ENVELOPE SHALL BE TOILET 17 ALL HORIZONTAL FRAMING BEARING ON BEAMS, 61RDER5 OR PARTITION TOP PLATES SEALED To THE DRYWALL BE AIR TIGHT AND IG RATED. CONTRACTOR IO• ALL FOOTINGS SHALL BEAR ON UNDISTURBED 501E WITH MINIMUM BEARING CAPACITY TO BE SELECTED SHALL BE LAPPED 4 MINIMUM. BATT INSULATION SHALL 13E GUT NEATLY T SHOWER BODY OWNER OF I TONS/SF BEARING CAPACITY. CONTRACTOR SHALL HAVE THE LEVEL OF PLUMBING AND MIRING a NEW BATH #2 FIT AROUND WIRING AND PLUMBING IN ACCEPTABLE BEARII�16 STRATA VERIFIED IN FIELD. 18 ALL HEADERS TO BE SUPPORTED BY MINIMUM (2) 2"x4" OR 4"x4" P05T5 UNLE55 EXTERIOR WALLS,OR INSULATION THAT ON CONTRACTOR „ OTHERWISE NOTED. INSTALLATION READILY CONFORMS TO TO BE SELECTED II. ALL POURED CONCRETE SLABS ARE TO BE 4 THICK WITH 6X6, 10/10 W.W.M. OVER 6 AVAILABLE SPACE SHALL EXTEND BEHIND 1O LAVATORY # NEW BATH #3 OWNER MIL. POLYETHENE VAPOR BARRIER OVER 6 COMPACTED GRAVEL. UNLESS INSULATION / VENTILATION NOTES PIPING AND WIRING FAUCET CONTRACTOR OTHERWISE NOTED. 5HOhER/TUB O THE AIR BARRIER INSTALLED AT EXTERIOR RECESSED LIGHT FIXTURES INSTALLED IN 1 THIS PROJECT HAS BEENDESIGNED TO MEET THE REQUIREMENTS OF THE NEW PORK EEXTERIOR Wa WALLS ADJACENT TO SHOWERS AND TUBS BE AIR TIGHT AND IG RATED. I I TOILET NEW BATH #3 THE BUILDING THERMAL ENVELOPE SHALL TO BE SELECTED OWNER 12• ALL CONCRETE 5HA-L BE VIBRATED IN ACCORDANCE WITH STANDARDS SET FORTH SHALL SEPARATE THEM FROM THE SHOWERS STRUCTURAL KUROS SORBI-AVA ENGINEERING STATE ENERGY CODE. THERE SHALL BE NO DEVIATION FROM THE R VALUES INDICATED AND TUBS CONTRACTOR BY THE AGI AND GENERALLY ACCEPTED BUILDING PRACTICE. ON THE DRAWIN65. TO BE SELECTED ENGINEER: 169 COMMACK ROAD FI FrTRIGAV THE AIR BARRIER SHALL BE INSTALLED BEHIND 12 SHOWER BASE 4 NEW BATH #3 OWNER SUITE H-362 13. ALL CONCRETE BLOCK SHALL CONFORM TO A5TM G90; MORTAR SHALL BE TYPE "M" 2 ALL PENETRATIONS THROUGH FLOORS AND RIM BOARD5 FOR ELECTRICAL AND PHONE BOX ON ELECTRICAL OR GOMMUNIGATION5 BOXE5 OR SHOWER BODY CONTRAGTOR COMMACK, NY 11725 MECHANICAL/PLUMBIN6 AGGE55 ARE TO BE FILLED COMPLETELY WITH EXPANDING EXTERIOR AIR SEALED BOXES SHALL BE INSTALLED FOAM SEALANT. O TO BE SELECTED OWNER 631-355-5556 LAVATORY 4 HVAG REGIS HVAG REGISTER BOOTS THAT PENETRATE 13 RENO. BATH #4 FOUNDATION W>4TERPROOFING 3 ALL GAVITIE5 AT WINDOW AND DOOR OPENIN65 SHALL BE FILLED WITH MINIMAL BOOTS �N TO THE THERMAL ENVELOPE E DRYWALL FAUCET GONTRAGTOR EXPANDING FOAM SEALANT SPECIFICALLY DE516NED FOR WINDOW AND DOOR USE. WALL HUNG TO BE SELECTED OWNER 1• FOUNDATION WALL EXTERIOR SURFACES TO BE PROTECTED FROM BOTTOM OF CONCEALED WHEN REQUIRED TO BE SEALED CONGEALED FIRE14 RENO. BATH #4 4 INSTALL INSULATION BAFFLES AT ALL VAULTED CEILINGS AND AT SOFFIT ENDS NEAR SPRINKLERS SHALL ONLY BE SEALED IN A TOILET FOOTING TO WITHIN V OF FINISHED GRADE WITH THE SPRAYED APPLICATION OF SPRINKLERS CONTRACTOR TOP PLATES TO PROVIDE UNINTERRUPTED AIR FLOW TO RIDGE VENT. THAT IS RECOMMENDED BY THE > 'TUFF N DRI'. PROVIDE BACK FILL PROTECTION BOARD. MANUFACTURER. CAULKING OR OTHER ADHESIVE BATHTUB 4 TO BE SELECTED OWNER " 5 R106E VENTS AS INDICATED ARE TO BE SHINGLE-VENT it AS MANUFACTURED BY SEALANTS SHALL NOT BE USED TO FILL VOIDS 15 RENO. BATH #4 5HOWER BODY "AIR-VENT" BETWEEN FIRE SPRINKLER COVER PLATES AND CONTRACTOR STRUCTURAL STEEL ROOFING NOTES WALLS OR CEILINGS 16 SHOWER BASE KENO. BATH #5 TO BE SELECTED OWNER O SHOWER BODY CONTRACTOR I. ALL STEEL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE A15G I A5 PER SECTION R905.1.2 OF THE NYS RESIDENTIAL BUILDING CODE AN ICE BARRIER TO BE SELECTED "SPECIFICATIONS FOR DE516N, FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL BE INSTALLED FOR ASPHALT 5HIN6LE5, METAL ROOF SHINGLES, 17 LAVATORY 4 RENO. BATH #5 OWNER FOR BUILDIN65". STEEL SHALL CONFORM TO A5TM A-572 (GRADE 50) AND A-501 MINERAL-SURFACED ROLL ROOFING, SLATE AND SLATE-TYPE SHINGLES, WOOD O FAUCET 5HIN&LE5 AND WOOD SHAKES. THE ICE BARRIER SHALL GON515T OF NOT FEWER THAN CONTRACTOR M TWO LAYER-5 OFUNDERLAYMENT CEMENTED TOGETHER, OR A SELF ADHERING TO BE SELECTED OWNER y DEMOLITION POLYMER-MODIFIED BITUMEN SHEET SHALL BE USE IN PLACE OF NORMAL IS TOILET KENO. BATH #5 UNDERLAYMENT AND EXTEND FROM THE LOWEST EDGES OF ALL ROOF SURFAGES TO A CONTRACTOR I I REFER TO CONSTRUCTION DOCUMENTS FOR SPECIFIC DEMOLITION LOCATION/NOTE5. POINT NOT LE55 THAN 24 INCHES INSIDE THE EXTERIOR WALL OF THE BUILDIN6. ON ROOFS WITH SLOPE EQUAL TO OR GREATER THAN 8 UNITS VERTICAL IN 12 UNITS 2 WHERE EXISTING WA15 ARE SHOWN TO BE REMOVED AND/OR NEW OPENIN65 ARE HORIZONTAL, THE ICE BARRIER SHALL AL50 BE APPLIED NOT LE55 THAN 36 INCHES DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. GALLED FOR IN EX15TIN6 WALLS, THE CONTRACTOR SHALL BRACE/51UPPORT ROOF, MEA54JRED ALONG THE ROOF SLOPE FROM THE SAVE E06E OF THE BUILDING. GEILIN6 AND/OR WALL PRIOR TO REMOVAL OF EXISTING WALLS, GEILIN6 J015T5 AND 255 MAIN STREET SUITE 200 H U N T I N G T O N, NY 1 1 7 4 3 ROOF RAFTERS, AND MAINTAIN SUCH GONDITION(5) UNTIL NEW HEADERS OR BEAMS Per I NTI NG NOTES P. 631.271.5400 WWW.DDANY.NET ARE INSTALLED AS SPECIFIED. EXIST. coPy:i�nc ©2oz5 AIIRightsResenred. I EXTERIOR TRIM MUST BE PREPPED AND PAINTED AS PER MANUFACTURERS " VENT 3 THE GENERAL CONTRACTOR 15 RESPONSIBLE FOR MAINTAINING THE STRUCTURAL REQUIREMENTS, IN OWNER SELECTED COLOR 3" VENT THRU OOF SEAL: - _ PROJECT NORTH: WN THRU ROOF ROOF LINE INTEGRITY OF THE PROJECT AT ALL TIMES. 2 ALL EXTERIOR COLUMNS AND COLUMN WRAPS MUST BE PREPPED AND PAINTED A5 PER MANUFACTURERS REQUIREMENTS, IN OWNER SELECTED COLOR 4 ANY DISC REPANCIE-5 RELATED TO THE DRAWINGS WITH THE ACTUAL STRUCTURAL 1 CONDITIONS THAT EXI5T SHALL BE REPORTED TO THE ARCHITECT PRIOR TO SIZE OF TRAPS FOR PLUMBING FIXTURES COMMENCEMENT WITH SAID WORK. RENO. BATH #4 i NEW BATH #2 NEW BATH #3 I RENO. BATH #5 P3[REFER TO TABLE 201.'1 OF THE RESIDENTIAL CODE OF NYS] a, _ 211 PLUMBING FIXTURE -C2��-r �2�� r--� �,I �2„ ARCHITECTURAL NOTES r I I I I 2" IZ-2" r t2 I i „� 11/2" 1 1/2" 1 1/2" 1 1/2 1 1/2 11/2 1 1/2 1 1/2 --1 BATHTUB (WITH OR WITHOUT SHOWER HEAD I I �' "� �' I THE DUTIES OF THE ARCHITECT, H15 EMPLOYEES AND A6ENT5 SHALL TERMINATE WITH AND/OR WHIRLPOOL ATTACHMENTS I Y2" r 1 1/2" I i 1 1/2"--1 1 I I I r 1 1/2" �-1 1/2" THE COMPLETION AND DELIVERY OF CONSTRUCTION DOCUMENTS. THE ARCHITECT I I I I I II � I PROJECT TITLE: HAS NOT BEEN RETAINED FOR AND 15 NOT RESPONSIBLE FOR CONSTRUCTION BIDET I Y4" I WATER LAVAITORY I I WATER I LAVATORY LAVAITORY I WATER I LA TORY I WATER OBSERVATION FOR THI5 PROJECT NOR DOES THE ARCHITECT HAVE THE AUTHORITY I I CLOSET I (CLOSET I I OL05ETI I I CLOSET RENOVATIONS & ALTERATIONS TO THE: TO ACT ON BEHALF OF THE OWNEP, ANY DEVIATION FROM THE GON5TRUCTION CLOTHES WASHER STANDPIPE 2" NEW I BATHTUB I I 1 I I I I 1 DOCUMENTS SHALL BE PRE-APPROVED IN WRITING BY THE ARCHITECT OF RECORD. 31 VENT IT SHALL BE THE 50LE RESPONSIBILITY OF THE CONTRACTOR TO RETAIN A DISHWASHER (ON SEPARATE TRAP) 1 Y2" THRu OF I I I SHOWER I I I I SHOWER 15HOWER I M I N E ILL RESIDENCE 1 I 11/2" I I 11/2" 11/2" I 1 11/2" LICENSED PROFE55IONAL TO LEGALIZE AND MAINTAIN ANY MODIFICATION TO THE FLOOR DRAIN 2" I I -J �4 w , I I FINISHED SECOND CONSTRUCTION DOCUMENTS WHICH HAS NOT BEEN PRE-APPROVED BY THE - - " - - - - - FLOOR ARCHITECT OF RECORD. KITCHEN SINK ONE OR TWO TRAPS, W/ OR „ I 2 3" 1 2 3" 3" 211 211 3" W/o D15HWA5HER 4 FOOD WASTE DISPOSER 1 Y2 RY I 3, 710 OLD MENHADEN ROAD 2 THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR THE ACTS OR OMI5510N5 OF THE LAUNDRY TUB (ONE OR MORE COMPARTMENTS) 1 Y2" NEW LAUND RENO. BATH #I_ _ _ _ 1 RENO. KITCHEN CUTCHOGUE , NEW YORK 11935 CONTRACTOR OR ANY OTHER SUBCONTRACTOR OR ANY OF THE CONTRACTOR'S OR LAVATORY I Y4" r2 i _-7 i 2 i C 5UBC.ONTRAGTOR'5 EMPLOYEES OR AGENTS, OR ANY OTHER PERSONS PERFORMING ��r 2 t 2 2 DRAWING TITLE: ANY OF THE WORK. SHOWER (BASED ON THE TOTAL FLOW RA {-1 1/2 1--1 1/2 11/2,. " t-1 1/2" 1 1/2" AIR ADMITTANCE GENERAL NOTES 3 THE ARCHITECT 15 NOT RE5PON51BLE FOR THE MEANS AND METHODS OF THROUGH 5HOWERHEAD5 4 BODY5PRAY5) I I I I I VALVE REOU I RED SIGN POSTING CONSTRUCTION NOR FOR SAFETY ON THE JOB SITE, AND THAT THESE FLOW RATE: 11 51 K 1 I 1 WATER LAVAITORY 51TTK RESPONSIBILITIES ARE INTENDED TO BE AND SHALL REMAIN SOLELY THE 5.1 GPM AND LE55 I Y2 1 I I CLOSET D w PLUMS I NG FIXTURE SCHEDULE RESPONSIBILITY OF THE GENERAL CONTRACTOR. MORE THAN 5.1 GPM UP TO 12.3 GPM 2 I WASHER I MORE THAN 12.3 GPM UP TO 25.5 GPM 3" I I PLUMBING RISER D I>�GR>4M 4 BY ACCEPTANCE OF THESE DRAWIN65, THE OWNER A6REE5 TO A58UME FULL MORE THAN 25.8 6PM UP TO 55.b GPM 4" EXISTING 3" FAI 1 1/2" 2" SHOWER 1 1/2" RESPONSIBILITY FOR ANY DAMAGE OR SETTLEMENT, OR GRAGKIN6 (ETC) OF NEW ( I 71 FINISHED FIRST GON5TRUGTION AND WILL NOT HOLD THE ARCHITECT RESPONSIBLE FOR THI5 NOTE-• ------ --- _1 3" T_- 2„ 3„ 2„ FLOOR P0551BILITY. AS PER NYS RESIDENTIAL CODE SECTION P3103.2 FROST GL05URE. WHERE THE Q7.5% 4" G.O. 5 ALL SURVEYS, TEST BORINGS, ENGINEERING REPORTS OR OTHER 51MILAR STUDIES VALUE FOR OUTSIDE DE516N TEMPERATURE 15 0°F OR LESS, VENT EXTENSIONS C Tu 3" 3" 3" 3" 3° DRAWN BY: 5DE SHEET NO. REQUIRED FOR THE PREPARATIONS OF THESE CONSTRUCTION DOCUMENTS AND/OR THROU6H ROOF OR WALL SHALL BE NOT LE55 THAN 3" IN DIA. ANY INCREASE IN THE TO EX15T Q REQUIRED DURING THE SUBSEQUENT CONSTRUCTION PHASE OF THE PROJECT SHALL SIZE OF THE VENT SHALL BE MADE NOT LE55 THAN I' IN51DE THE THERMAL ENVELOPE SEPTIC CHECKED BY: 5J5 BE PROVIDED BY Tf-1E OWNER. OF THE BUILDING. SYSTEM DATE: 10.20.25 6 ALL CONTRACTORS THAT HAVE 516NED CONTRACTS WITH THE OWNER SHALL HAVE NOTE: Aml 00 THE OWNER AND ARCHITECT OF RECORD LISTED AS AN ADDITIONAL INSURED AND AS PER NY5 RESIDENTIAL CODE SECTION P3103.1.1 ROOF EXTENSION. OPEN VENT PIPES BASEMENT SCALE: A5 NOTED SHALL CARRY POSITIVE STATEMENT THAT THE SPECIFIC COVERAGE REQUIRED ARE THAT EXTEND THROUGH A ROOF SHALL BE TERMINATED NOT LE55 THAN b" ABOVE THE NOTE: (2) H05E 6165 ARE TO BE INSTALLED ON THE EXTERIOR OF HOUSE FLOOR PROVIDED. HE SHALL HOLD HARMLE:55 THE ARCHITECT AND OWNER AGAINST ANY ROOF OR 6" ABOVE THE ANTICIPATED 5NOW ACCUMULATION, WHIGHEVER 15 GREATER. 2 FLO�-*15IN6 R15ER1:;) 1A6RAM AND ALL CLAIMS ARISING FROM WORK PERFORMED BY HIS EMPLOYEES AND ANY NOTE: PROJECT N0. 2515 SUBCONTRACTOR AND HI5 EMPLOYEE5 BY ACCEPTANCE OF THESE DOCUMENTS. AI OO N.T.S. PLUMBER TO EVALUATE EXI5TIN6 DOMESTIC HOT WATER CAPACITY AND PIPING SUPPLY SIZES AND INCREASE SAME AS R.EOV. L 777 Z EEMCLITION NOTESz, THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY LINE OF WALLS, DOORS, WINDOWS, ETC. TO BE REMOVED; PROVIDE ALL TEMPORARY SHORIN& AS THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE,AND ARE AND SHALL REQUIRED (TYPJ REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER (DLINE OF DOORS, WINDOWS, ETC. TO BE REMOVED; STORE SECURELY ON SITE FOR RELOCATION LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE (COOFIDINATE STORAGE v4/ OWNER) ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. CREMOVE EXIST. CABINETS, AND APPLIANCES IN THEIR ENTIRETY; REFRIGERATOR AND DISHWASHER IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION DTO BE STORED SECURELY ON SITE FOR REU5E (COORDINATE STORAGE Pq/ OWNER) OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL IO N REMOVE EXIST. SINK GAP LINES AS REQUIRED; STORE SINK AND FAUCET ON SITE FOR POSSIBLE ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION"ALTERED BY REUSE (COORDINATE STORAGE P4/ OWNER) FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE O REMOVE EXIST. PLUMBING FIXTURES IN THEIR ENTIRETY; CAP LINES AS REQUIRED SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION LAW ARTICLE 147-ARCHITECTURE,SECTION 7307) REMOVE EXIST. TILE FLOORING; PATCH AND REPAIR AS REQ'D. TO PREP FOR NEW FLOORING; COORDINATE Pi/ CONSTRUCTION PLAN ISSUANCE: (D EXISTING ROOF TO BE REMOVED FROM THIS POINT BACK FOR ADDITIONS; COORDINATE EXTENT NO. DATE: DESCRIPTION:WITH CON5TRUGTION PLAN 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING OEXISTING WASHER AND DRYER TO BE REMOVED; STORE SECURELY ON 51TE FOR RELOCATION TO NEW LAUNDRY ROOM; CUT AND CAP LINES AS REG-D. EXIST. LINE OF ROOF ABOVE TO REMAIN SHOWN DOTTED (TYP) PECK OSHOWN EL. (-)1'-3 1/2" 10 EXIST. H05E BIB TO BE REMOVED; CUT AND CAP LINES AS REO'D. 11 EXIST. REF. TO BE REMOVED; STORE SECURELY ON 51TE FOR RELOCATION TO NEW 6ARA6E EXIST. PATIO 12 EXIST. DEEP FREEZER TO BE REMOVED; STORE SECURELY ON SITE FOR RELOCATION TO NEW �EL. 5/4" GARAGE 13 EXIST. POT HANGING RACK TO BE REMOVED; PATCH AND REPAIR CEILING AS REQD. 14 REMOVE GARAGE SLAB AS REO'D. FOR NEW GARAGE SLAB PITCH. 1 2 1 TF T— fr===L1 EXIST. EXIST. EXIST. j j II I DEN PORCH KITCHEN 2 III II I 4 F--1 it 7 7 2 II ---------------------------- -T- Li r 0 STRUCTURAL KUROS SORBI-AVA ENGINEERING ENGINEER: 169 COMMACK ROAD LA SUITE H-362 EXIST. COMMACK, NY 11725 DINING ROOM 631-355-5556 ------- 1 100, F- L----A n NEXI� Y e, I X15T.kcg I NTH #1 1 00 EX L----- 2 10 L 2� 1114' 111,11 IL_j I I I I III EXIST, AN. CLO5. DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. 4------------------------------------ ---- ----- 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 EX15TIN6 EXIST. P. 631.271.5400 WWW.DDANY.NET GARAGE EXISTING LIVIN(5 ROOM Copyright @ 2025 All Rights Reserved. FOYER SEAL: PROJECT NORTH: ------- *EL. 01-011 L F----------------- PROJECT TITLE: EXIST.' PORCH Lz RENOVATIONS & ALTERATIONS TO THE: LO`--7 IL2- NOTE: GENERAL GONTRAGTOR TO COORDINATE 4 SUPERVISE W OWNER RETAINED MOVING McNEILL RESIDENCE ------ COMPANY TO REMOVE 4 STORE OWNER F"15HIN65. GENERAL CONTRACTOR TO COORDINATE 4 5LFERV15E RETURN OF OWNER FURN15HIN6 AT GOMPLETION OF a FO-1 CONSTRUCTION. 111 710 OLD MENHADEN ROAD WALL LEGEND CUTCHOGUE , NEW YORK 11935 N.T.S. DRAWING TITLE: KALL5/GON5TRUGTION TO BE REMOVED. PATGH/REPAIR ALL SURFACES ADJACENT TO DEMO WITH MATERIALS TO MATCH FIRST FLOOR AND ALIGN FLUSH WITH EXISTING. DEMOLITION PLAN NEW HALL CONSTRUCTION: INTERIOR V4ALL5: U.O.N. NOTES AND DETAILS YY GYPSUM WALL BOARD OVER 2"X4" V400D STUDS @ 16"o.c. EXTERIOR HALLS:-U.O.N. 'HYDR06AP' HOUSE WRAP AS MANUF. BY BENJAMIN OBDYKE OVERY2" CDX PLYWOOD OVER 2"xb" WOOD STUDS @ 16" o.c. I/V %" R-21 BATT INSULATION AND XY GYPSUM WALL BOARD. DRAWN BY: 5DE SHEET NO. NEW FOUNDATION WALL CHECKED BY: SJS EXISTING WALL CONSTRUCTION TO REMAIN DATE: 10.20.25 Am101 f I fi S T f-02 L O O �EMCL M C N PLAN NOTE:- SCALE: AS NO-FED ALL GYPSUM WALLS AND CEILINGS ARE TO BE TAPED AND 5PACKLED (THREE A101 1/4-, = v—o-, GOAT5) AND PAINTED WITH ONE COAT PRIMER AND TWO GOATS FIN15HED COLOR PROJECT No. 2515 AS SELECTED BY OWNER. PROVIDE WATER RE-515TANT GYPSUM WALL BOARD IN REFER TO DEMOLITION NOTES FOR ADDITIONAL REQUIREMENTS ALL DAMP/ NET LOCATIONS. 77 IL Lj I 1:)EMOL1710N. NOTES a77-7-7 THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY OLINE OF WALLS, DOORS, WINDOWS, ETC. TO BE REMOVED; PROVIDE ALL TEMPORARY THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE,AND ARE AND SHALL 1 REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE 5HORIN6 AS REQUIRED (TYP) INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE GD EXIST. WINDOW TO BE REMOVED; STORE ON 51TE FOR RELOCATION ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. - O3 REMOVE EXIST. PLUMBING FIXTURES IN THEIR ENTIRETY; GAP LINES AS REQUIRED IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING 4 REMOVE EXIST. TILE FLOORING; PATCH AND REPAIR AS REQ D. TO PREP FOR NEW FLOORING ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION"ALTERED BY' FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE -- ---- ------ - -- O EXIST. PULL DOWN ATTIC ACCESS TO BE REMOVED; STORE ON 51TE FOR RELOGATION SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION LAW ARTICLE 147-ARCHITECTURE,SECTION 7307) I ' OLINE OF ROOF ABOVE TO REMAIN SHOWN DOTTED (TYP) ISSUANCE: I OEXISTING ROOF TO BE REMOVED FROM HERE BACK FOR ADDITIONS; COORDINATE NO. DATE: DESCRIPTION: EXTENT WITH CONSTRUCTION PLAN � i i 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING I gO REMOVE EXISTING DEGKIN6 MATERIAL TO BE REPLACED; GUARD RAIL TO BE REMOVED AND STORED ON 51TE FOR RE-INSTALLATION O9 REMOVE EXISTING WINDOW TO BE REPLACED WITH LARGER UNIT i i I 1 / I - - - - - - - - 6 - - - - - - - - - I i II II I t - - - - - - - - - - - -I - - - - - - - -- ----- 1 =41 --- -_------� I I � Ii I III I I 3 II I I `>> I EXIST. I II I I j PRIMARY BATH I 11 I I I EXIST. I I (BATH #2) EXIST. II I WALK-IN GLOS. I I BALCONY II r , L----- FF-- I I I 4 II I I q EXIST. )III BEDROOM #3 I i II II o LJ II I IIII - - - - - - 1- 4 I I II __ ii I I L--J � - - - 1fi1— � \\ I II��y I I 1 L - - - - - - - - - - II ------------ G - - - - - - - - - - - - - ——————————— � LL.�� \ I I STRUCTURAL KUROS SORBI-AVA ENGINEERING I �\ \ I I ENGINEER: 169 COMMACK ROAD SUITE H-362 — — 6 3 3 I \\ I I COMMACK, NY 11725 � - - - - - - - - -'� - - - - - I \ EXIST. L _ 631-355-5556 1 I I I I PRIMARY BEDROOM (BEDROOM #1) I I �� IIII L HALL __ EXIST. I I I I FI - G'-11 I/8" I I 1 \ '°° I #3 I I II I \ 11 i 41 I I \ I I EXIST. I I I I EXIST. I EXIST. \ II t_I GLO5• I ❑ ❑ - - - - - - - - ', I . I t� I I I I 1 I DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. I I 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 I 2 EXIST. I I P. 631.271 .5400 WWW'DDANY.NET Copyright ©2025 All Rights Reserved. BEDROOM #2 I I SEAL: PROJECT NORTH: E�15T. I I = - - - - - I PROJECT TITLE: i I RENOVATIONS & ALTERATIONS TO THE: I � it L I McNEILL RESIDENCE — J 710 OLD MENHADEN ROAD WALL LEGEND CUTCHOGUE , NEW YORK 11935 N.T.S. DRAWING TITLE: WALLS/CONSTRUCTION TO BE REMOVED. PATCH/REPAIR ALL SURFAGE5 ADJACENT TO DEMO WITH MATERIALS TO MATCH SECOND FLOOR AND ALIGN FLUSH WITH EXISTING. DEMOLITION PLAN NEW WALL CONSTRUCTION: NOT E5 AND DETAILS INTERIOR WALLS: U.O.N. Y2" GYPSUM WALL BOARD OVER 2"x4" WOOD STUDS ® I6"o.c. EXTERIOR WALL5: U.O.N. 'HYDROGAP' HOUSE WRAP AS MANUF. BY BENJAMIN OBDYKE OVER Y2' CDX PLYWOOD OVER 2"x6" WOOD STUDS ® 16" o.c. W/ 5412" R-21 BATT INSULATION AND Y2" GYPSUM WALL BOARD. DRAWN BY: SDE SHEET NO. NEW FOUNDATION WALL CHECKED BY: S.IS Aml 02 NOTE: EXISTING WALL CONSTRUCTION TO REMAIN DATE: 10.20.25 5ECONI:) r—LOOR 1:) FLAN— ALL GYPSUM WALLS AND GEILIN65 ARE TO BE TAPED AND 5PAGKLED (THREE SCALE: A5 NOTED AI02 1/4" = I'-O" GOATS) AND PAINTED WITH ONE COAT PRIMER AND TWO COATS FINISHED COLOR PROJECT NO. 2515 AS SELECTED BY OWNER. PROVIDE WATER RESISTANT GYPSUM WALL BOARD IN REFER TO DEMOLITION NOTES FOR ADDITIONAL REQUIREMENTS ALL DAMP/ NET LOGATION5. CON57RUC71 ON NOTES7777777,7 THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE,AND ARE AND SHALL 1 REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE LINE OF EXIST. FDN. WALL TO BE REMOVED/ CHOPPED TO BE BELOW NEW SLAB INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER (DTECT. THE 8" WIDE POURED CONCRETE FOUNDATION WALL W/ #4 CONTINUOUS HORIZONTAL BAR WITHIN 6" OF TOP OF ARCOHI ECTT SHALL BEODEEMED THE AUTHOR OFUT THE EXPRESS ITHEESE DOCUCONSENT OMENTS AND F THE I RETAINS ALL WALL W/ 50" OVERLAPPING a SPLICE POINTS$ #4 VERTICAL BARS a 48" O.G. W/ 6" EMBEDMENT INTO COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. FOOTING. W/12"x24" CONTINUOUS FOOTING TO BE 3'-0" BELOW GRADE MINIMUM W/ (2) #5 REBAR5 IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION CONTINUOUS, 5/a" 6ALV. ANCHOR BOLTS a 48" O.G. SEAM SEAL, COPPER FLASHING BETWEEN FOUNDATION $ OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I (1) 2x6 AGO. SILL PLATE $ (1) D. FIR 2x6 SILL PLATE; TUFF 4 DRY WATER PROOFING ON NEW FND. WALL; ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING TOP OF WALL TO AL16N W/ EXIST. ADJACENT; PROVIDE (R-10) RIGID IN5UL. ON IN51DE OF FND. WALL ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION'ALTERED BY' T - 8" WIDE POURED CONCRETE FOUNDATION WALL W/ (1) #4 VERTICAL BAR a 72" O.G. EXTENDED INTO FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE GD FOOTING, (I) WITHIN 6�� OF CORNERS AND OPENINGS, (I) #4 HORIZONTAL REPAR AT TOP w/ 3" COVER W/ SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION � LAW ARTICLE 147-ARCHITECTURE,SECTION 7307) 12"x24" CONTINUOUS FOOTING TO BE 3'-0" BELOW GRADE W/ (2) #5 REBAR5 CONTINUOUS; 5/a" 6ALV. ANCHOR BOLTS a 23" O.G. SEAM SEAL, COPPER FLASHING BETWEEN FOUNDATION 4 (1) 2x4 AGO. SILL ISSUANCE: PLATE $ (1) D. FIR 2x4 SILL PLATE i i OPROVIDE #5 DOWELS a 12" O.G. VERTICALLY. DRILL$ EPDXY GROUT 6" INTO N0. DATE: DESCRIPTION: EXISTING FOUNDATION WALL $ (2) #5 DOWELS INTO EXISTING FOOTING. 1. 10.20.21 ISSUED FOR BUILDING DEPARTMENT FILING O PROVIDE 2" THICK POURED CONCRETE VERMIN SLAB OVER 6 MIL POLYETHYLENE VAPOR RETARDER, 12 JOINTS LAPPED 6" MIN., OVER 4" COMPACTED COURSE GRAVEL; MAINTAIN MIN. 3'-0" UNDER FLOOR SPACE I � i CD PROVIDE STEP FOOTING AT 2'-0" MAX. HORIZONTAL AND 1'-0" MAX. VERTICAL I � I PROVIDE MIN. 4" P.G. SLAB W/ 6 MIL V.B. W/ bxbloxo NM OVER 6" COMPACTED POROUS FILL 7 COMPACTED TO c15% DENSITY W/ Y EXPANSION JOINT a PERIMETER WHERE SLAB MEETS FND. WALLS SEE GONG. $ FND. NOTES FOR ADDITIONAL REQUIREMENT5; PITCH SLAB TO GARAGE DOORYa" PER FOOT. SLAB TO MATCH AND ALIGN W/ EXIST. GARAGE SLAB; DOWEL INTO EXIST. SLAB 8 PROVIDE 16"x8" CRAWL 5PAGE VENT W/ IN5EGT SCREEN; PROVIDE (2) BOX BEAM OVER OPENING; VENT TO BE LOCATED WITHIN 36" OF CORNER AND BE INSTALLED WITHOUT OBSTRUCTION I i (�D SAW GUT FDN. AS REQ'D. TO PROVIDE 24"AW MIN. OPENING; PROVIDE (2) BOX BEAM OVER OPENING 4 INSULATED ACCESS PANEL ON FULL BASEMENT SIDE — — — — — — — — — O ATTACH 'SIMPSON' (HTT22) HOLD DOWN TO CORNER POST IMBED IN FND. 10 WALL W/ 'SIMP50N' (55TB) BOLT (SEE 4 ON A-400 FOR DETAILS) IF — — — — — — - I 11 ATTACH 'SIMP50N' (HTT22) HOLD DOWN TO KING POST IMBED IN FND. WALL W/ 'S1MP50N' (55TB) BOLT (SEE 4 ON A-400 FOR DETAILS) SEE FIRST FLOOR PLAN FOR LOCATION LINE OF STAIR/ DEGK ABOVE SHOWN DOTTED (TYP) 1 I _ J I- - - - - - - - - - - - I it LINE OF CRIPPLE WALL ABOVE (SHOWN DOTTED) TO BE 2"x4" WOOD STUDS a 16"o.c. W/ (1) 2x4 AGQ. 51LL A-300 I F -4 — — — — — — — — — 1 13 PLATE 4 (1) D. FIR 2x4 SILL PLATE SECURED TO EXIST. SLAB W/ P.A.F. PROVIDE COPPER TERMITE SHIELD i PROVIDE MIN. R-30 BATT IN5UL. IN F.J. BAYS v >x� I 15 POST FROM ABOVE TO BEAR SOLIDLY ON FDN. WALL I = o I I O ic14 EXISTING FULL BASEMENT (— 16 POST FROM ABOVE TO BEAR SOLIDLY ON GIRDER (SHOWN DOTTED) (UNFINISHED) I � 1 I 1 , 12 O STEEL COLUMN FROM ABOVE TO BEAR 50LIDLY ON FDN. WALL; PROVIDE 8"x 8"x 3/4" STEEL BASE PLATE, 13'-10 1/2" (+/- V.I.FJ lx �� I i 17 IF PLATE WILL BE OVER BEAM POCKET NOTIFY ARCHITECT 8" 13'-2 1/2"+/- 1 I w) 2'-O" 2'-0" I I 18 EXIST. 5TL. GOL 4 FOOTING TO REMAIN (TYP. U.O.N) 3-0 I I _ 8 I 1 17 I 1 ; 19 EXIST. 5TL. GOL TO REMAIN, FOOTING TO BE REMOVED (SEE NOTE #20 FOR NEW FOOTIN(5); PROVIDE TEMP — — —— ————— — —— I —— 22 I _ _ _ _ _ _ _' 5HORIN6 AS REQ'D. EXISTT�(3) 13/4"xil ?/8' L. .L. _ L NEW 3Y2 5GH. 40 (O.D. 4 ) 5TL. POST UNDER POST/ GIRDER ABOVE TO BEAR SOLIDLY ON 48 x48 xi2 DEEP O FOOTING W/ (4) #5 BARS EA WAY TO BEAR ON UNDISTURBED SOIL; PROVIDE GAP 4 BASE PLATE FOR FULL o I —I - - L — -- -- -- - - - - - - -� _ L _ 16 l 20 I I NEW I I BEARIN6 (INCLUDING EXIST. ADJACENT COL. TO REMAIN); WELD TO BE Y4" FILLET WELD. GAP PLATE LAG m �? GRAWL SPACE 2 4 18 18 L_— — J Ia I I BOLTS TO BE 3/a" IN PREDRILLED HOLES; 5/a" ANCHOR BOLTS FOR BASE PLATE W/ V EDGE DISTANCE. ]EXIST. 20 I I REPAIR P. GONG. SLAB AS REQ'D. SEE DETAIL THI5 SHEET FOR P05T GAP " 6 2 X ELEG. 21 I 21 5TL. COLUMN FROM ABOVE TO BEAR SOLIDLY ON 61RDER (SHOWN DOTTED). PROVIDE 5 Y4 (MIN)x8 x Y2 5TL. STRUCTURAL KUROS SORBI-AVA ENGINEERING N 5 14 23 (PANEL I I BASE PLATE FOR FULL BEARING; ATTACH W/ (4) %" DIA. LAG 5GREW5 INTO PREDRILLED HOLES ENGINEER: 169 COMMACK ROAD I O INSTALL '51MP50N' HIOA TIE ON F.J. WITHIN 2'-O" EA. 51DE OF NEW 5TL. COL. FROM ABOVE TO CONNECT TO SUITE H-362 1 J I ~O I 1 22 GIRDER COMMACK, NY 11725 _ _ _ _ _ J I I 23 PROVIDE 5/4" T46 PLY ND. W/ 6LUE/NAIL W/ PAGK UP AS REQ'D. FOR NEW FINISHED FLOOR TO ALIGN W/ 631-355-5556 Q I I 4 -I � ® I I EXIST. ADJACENT (TYP.) ALTERNATIVELY- 13/4"xc Y1' L.Y.L. OR a Y2" TJI F.J. MAY BE USED TO AVOID PACK UP I I I v Q EXIST. I I 24 PROVIDE MIN. 18x24 AG( TO BELOW FLOOR SPACE. COORDINATE LOCATION IN FIELD = 0 w 16 OIL TANK I 1 I I 2x10 F.J. I 1 �� I I ,.,. 1 a O G I IS EXIST. I I I 1 I I N ® I6 HVAC 18 EXIST. I I I I X OIL TANK 1 Lam, - - - - - - - — - - - - - - 1 l EXIT-T. (3 3/4"xi I �/8" L .L. I- - - - - , - - — — I � I . EXISTING T11 — 5LA13 ON GRADE I 2x10 F.J. NpE�13rYE2" SGH. 40 5TL. POST FROM I I a O.G. L---- I - - - � I 1 I L u rr rr 1 I 14 23 1 ----- I IS 18 I , 5 Y4 x8 x Y2 STEEL BA5EPLATE I 24 I 15 13 EXI5T. I ___ , ~p EXISTING I (4) 3/a" DIA. LA6 5GREW5 INTO _ __ DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. LAB i I I FULL BASEMENT I PREDRILLED HOLES U----� (UNFINISHED) I J i 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 — — — — — — �,L - - - - - - - I F- a I I i P. 631.271.5400 WWW.DDANY.NET 1 i Copyright ©2025 All Rights Reserved. IS Y - --- w I EXISTING L.Y.L. GIRDER TO REMAIN SEAL: ;, PROJECT NORTH: I NEW 1 SLAB I o I 1 1 I I � 3/brr UP EXTERIOR SIDES BOTH PLATES i I 7 L - - - - — — — — - - - - - - - - J L —I d 7"x8"xYY STEEL GAP PLATE II - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -� � � ; (4) 3/a" DIA. LA6 5GREW5 INTO I 1 I I i PREDRILLED HOLES PROJECT TITLE: SLAB ON6RADE D I I ' S _ RENOVATIONS & ALTERATIONS TO THE: I I I I i P05T Y2" SGH. 40 (O.D. 4") 5TL. �- INSTALL SMOKE DETECTOR AND CARBON L __ � MONOXIDE DETECTORS IN ACCORDANCE WITH ALL M c N E I LL RESIDENCE — —_— _ J STATE AND LOCAL CODE REQUIREMENTS. SINGLE I __ _ ___________ __ I AND MULTIPLE STATION SMOKE ALARMS AS PER THE RE51DENTIAL CODE OF NY5 R-314, R-515 AND L q I 4 F -1 F -1 12 F - i AJ801.3.1, WIRED IN SERIES I L —I L J L I L I L -1 ; L 710 OLD MENHADEN ROAD Q0. I I `; -I---15--------------------------- ---- ----- ----------------------J 2 F057 C P 1:)E!7 1 NALL LEGEND CUTCHOGUE NEW YORK 11935 cV r I3 7 3 N.T.S. DRAWING TITLE: A103 1 1/2" = 1'-0" WALLS/CONSTRUGTION TO BE REMOVED. PATCH/REPAIR ALL SURFAGE5 ADJACENT TO DEMO WITH MATERIALS TO MATCH FOUNDATION PLAN AND ALIGN FLUSH WITH EXI5TIN6. I r/,� 10 I NOTES AND DET�IL5 - -- - -- 11 J NEW WALL CONSTRUCTION: INTERIOR WALLS: U.O.N. L — — — —— —— —————— — — Y2" 6YP5UM WALL BOARD OVER 2"x4" WOOD STUDS a 16"o.c. a'-4"+/- I'-10" 8' EXTERIOR WALL5: U.O.N. 14'-4" (+/- V.I.F) 'HYDR06AP' HOUSE WRAP AS MANUF. BY BENJAMIN OBDYKE OVER Y2" GDX PLYWOOD OVER 2"xb" WOOD STUDS a 16" o.c. W/ 5v2" R-21 BATT INSULATION AND Y2" GYPSUM WALL BOARD. DRAWN BY: 5DE SHEET NO. • -. .: NEW FOUNDATION WALL CHECKED BY: rj,I5 EXISTING WALL CONSTRUCTION TO REMAIN DATE: 10.20.25 f=CUN=�A71 ON FLAN NOTE: NOTE: NOTE: ®103 PROVIDE 'GETGO' YOLGLAY WATERSTOP-RX 101 CONCRETE JOINT WATERSTOP A-F- DIMENSION TAKEN TO GONG. POUR ALL GYPSUM WALLS AND CEILINGS ARE TO BE TAPED AND SPAGKLED (THREE SCALE: A5 NOTED A103 1/4" = 1'-O° VERTICALLY WHERE NEW CONCRETE POUR JOINS EXISTING POURED CONCRETE. GOATS) AND PAINTED WITH ONE GOAT PRIMER AND TWO GOATS FINISHED COLOR INSTALL AS PER MANUFAGTURE5 5PEGIFIGATION5. PROVIDE WATERPROOF MEMBRANE FLASHING NOTE: PROJECT N0. 2515 PROVIDE 'YORKSHIELD' IO&T5 COPPER FLA5HIN6 WHERE WOOD MEETS MASONRY (TYPJ AS SELECTED OWNER. PROVIDE WATER RESISTANT GYPSUM WALL BOARD IN 22'-On TO EACH SIDE WHERE NEW CONCRETE JOINS EXIST. POURED CONCRETE ALL DAMP/ NET LOCATIONS. I i CON57RUC71 ON NOES L16H7/\/EN7 CALOULA710NS ; : THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY NEW DEN REQUIRED LIGHT TRANSMITTING AREA = THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE,AND ARE AND SHALL PROVIDE 5/e" GYP. BD. ON WALL5 AND GEILIN6 OF GARAGE (TYP.) REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE 1 AREA = 202.5 50.F7. 202.5 50.FT. X b% = 16.2 50.FT _ / INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER PROPOSED WINDOW L16HT TRANSMITTING AREA=36.2 5Q.FT. V LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE O LINE OF FND. WALL BELOW ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL REQUIRED AIR VENTILATION AREA = COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. O LINE OF WALL ABOVE SHOWN DOTTED 202.5 50.FT. X 4% = 5.1 50.FT IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION PROPOSED WINDOW AIR VENTILATION = 15.3 50.FT. ✓ OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I 4O LINE OF ROOF ABOVE SHOWN DOTTED (TYPJ ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING NEW LAUNDRY REQUIRED LIGHT TRANSMITTING AREA = ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION'ALTERED BY" AREA = 71.7 5Q.FT. 71.1 5Q.FT. X 8% = 5.7 5Q.FT FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE 5 RELOCATED GARAGE DOOR PROPOSED WINDOW LIGHT TRANSMITTING AREA=5.74 SQ.FT. SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION LAW ARTICLE 147-ARCHITECTURE,SECTION 7307) CD INSTALL WINDOW UNIT RELOCATED FROM EXIST. 6ARA6E REQUIRED AIR VENTILATION AREA = ISSUANCE: 11.1 50.FT. X 4% = 2.11 50.FT. 7 PROVIDE STEPS TO HAVE ACQ. 5TRIN6ER, FINISH TREADS w/ OAK OR APPROVED EQUAL TO PROPOSED WINDOW AIR VENTILATION = 32 50.FT. ✓ NO. DATE: DESCRIPTION: COMPLY W/ NY5 RESIDENTIAL CODE 8 INSTALL RELOCATED FRID6E FROM EXISTING GARAGE RENO. KITCHEN/ REQUIRED L16HT TRANSMITTING 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING AREA = EAT IN AREA 436A 50.FT. X 8% = 35.0 50.FT EXIST DECK. 9O INSTALL RELOCATED FREEZER FROM EXISTING GARAGE AREA= 436A 50.FT. PROPOSED WINDOW/DOOR L16HT TRAN5MITTIN6 AREA=82.q 50.FT. _I$)_EL. (-)1'-3 1/2" REQUIRED AIR VENTILATION AREA = 10 INSTALL OWNER SELECTED STORAGE 5HELVIN6; PROVIDE BLOGKIN6 AS REQ'D. 43bA 50.FT. X 4% = 17.5 50.FT. PROPOSED WINDOWS DOOR AIR VENTILATION = 40D 50.FT. 11 PATCH 4 REPAIR WALL TO MATCH 4 AL16N w/ EXIST. ADJACENT EXIST. NEW HOME OFFICE REQUIRED LIGHT TRANSMITTING AREA = PATIO FURR OUT WALL AS REQ'D. TO ALG6N w/ NEW 2x6 WALL FRAMIN6; PROVIDE 4 �EL. (-)I'-6 3/4" 12 R-21 BATT IN5UL. IN STUD BAYS AREA - 82 Q SQ FT PROPOSED WINDOW LIGHT TRANSMITT N6 AREAS--2 .O SQ.FT. 13 PROVIDE AND INSTALL NEW WOOD FLOORING TO MATCH EXISTING; FINISH w/ OWNER SELECTED WATER BASED FINISHES REQUIRED AIR VENTILATION AREA = 82A 50.FT. X 4% = 3.3 5Q.FT. ON, 14 RE-INSTALL DRYER;VENT TO OUTSIDE PER NY5 RESIDENTIAL CODE PROPOSED WINDOW AIR VENTILATION = q.0 50.FT. ✓ I'-7" 11Z4 112" 7'-q 5/8"+/- 15 RE-INSTALL WASHING MACHINE TIE INTO EXIST. WA5TE LINE (V.I.F) 31 I II II 32 O PROVIDE AND INSTALL OWNER SELECTED 5TORA6E ABOVE w/ DRYING RACK; 16 PROVIDE BLOCKING AS REQ'D. 52C TW2 2G 1 +I --I-_y 28 DN. 17 PROVIDE AND INSTALL OWNER SELECTED TILE FLOORING - I 1 A-300 _J I 2'6"x6'8, �, SD I 18 PROVIDE EXHAUST FAN VENTED TO EXTERIOR ELECTRICAL NOTE: `r -----a I I � I PROVIDE ALL ELECTRICAL OUTLETS, SWITCHES, ETC. Li PATCH AND REPAIR WOOD FLOORING AS REQ'D. (TYP. OF AREA OF WORK, EXGLUDIN6 AGCORDIN6 TO ALL STATE AND LOCAL CODES. 19 BATHROOMS) COORDINATE WITH ITH OWNER, LOCATIONS OF ALL ADDITIONAL 23 5WITGHIN6, OUTLETS AND L16HTING. 11 0 i i i NEW NEW EXIST. I Zp REMOVE EXIST. SIDING 4 SHEATHING; GAT ® MID-SPAN PROVIDE Y2" GYP. BD. 25 I I EAT-IN HOME OFFICE PORCH I I- PROVIDE R EGTRIGAL CONVENIENCE RECEPTACLE 13'-10 I/2" (+/- V.I.FJ I ' AREA (NO SLEEPING) I 21 OWNER SELECTED FOLDING TABLE Pi/ STORAGE CABINET d SINK (SEE PLUMBING OUTLETS PER E3g01 6 I/ 13'-4"(+/-) i I 271 34 I FIXTURE SCHEDULE) 5-II I/2 4 I/2 7-0 " I I I 22 OWNER SELECTED 2'-6" FIRE RATED DOOR 4 A55EMBLY w/ SELF CLOSING HARDWARE TO 2- PROVIDE CONVENIENCE RECEPTACLE OUTLET IN I 26 i I BE 20 MINUTE RATED; DOOR STYLE TO MATCH EXI5TIN6 DOOR STYLE 4 PROFILES GARAGE, PER E3aOI.q WITH 6FGI, PER E3g022 4 U i i Iq I GDDE516NER RELOCATED KITCHEN WINDOW TO BE CENTERED ON SINK; COORDINATE w/ KITCHEN 3- PROVIDE ONE WALL SWITCH CONTROLLED LIGHTING ON 0 HAV NEXTERIOR GRRADE 51DE OF EACH AC-GE55 OUTDOOR DACCORDANCE WIOR TH All - 10 -,-� I L____1--J 24 RE-INSTALL REFRIGERATOR E3gO3.3 5T0. i i RENOVATED - L_'." 'z KITCHEN Iq d� u�l 25 OWNER SELECTED MILLWORK COORDINATE w/ KITCHEN DESIGNER 4- 6FGI's ARE TO BE PROVIDED, PER E3g02 x O Iq O OWNER SELECTED 36" INDUCTION RANGE w/ OWNER SELECTED RAN6E HOOD PIPED ml !!p;" 14 I7 O z6 TO EXTERIOR PER NY5 RESIDENTIAL CODE. 25 Za m PLUMBIN6 NOTE: STRUCTURAL KUROS SORBI-AVA ENGINEERING NEW LAUNDRY E 0 I O q� w I- MATERIALS FOR WATER SUPPLY AND D15TRIBUTION ENGINEER: 169 COMMACK ROAD �--I 20 cV °- - 27 OWNER SELECTED 3'-4"xq'-4" ISLAND COORDINATE w/ KITCHEN DESIGNER SYSTEMS, PER TABLES P2g06.4., P2a06.5, P2g06.6 SUITE H-362 m -- ------- +�° iv COMMACK, NY 11725 -__I_-- � z RENO.� 24 -------- I I tt 28 RE-INSTALL DISHWASHER 2- MATERIALS FOR DRAINS, WASTE AND VENTS PER 631-355-5556 4'-0" 411211 DINING ROOM TABLE5 P3002.1 AND P31113 Q 12 II 25 OWNER'S 29 OWNER SELECTED WINE/ BEVERA6E FRIDGE 11 "I CLOSET WINDOW/ DOOR NOTE: -�I= 71 2 3O 30 INSTALL OWNER SELECTED STORAGE SHELVING; PROVIDE LOCK ON DOOR TO BE ALL NEW WINDOWS TO BE MANUFACTURED BY "ANDERSEN". SD 30 % O KEYED TO OWNER KEY MODEL NUMBER AS INDICATED ON PLANS. ALL NEW WINDOWS x Q SD ® TO COMPLY WITH THE RESIDENTIAL CODE OF NEW YORK 31 PROVIDE AND INSTALL NEW OWNER SELECTED SCREEN DOOR ASSEMBLY II _ L 18 STOR. STATE. TO BE 400 SERIES WITH �Yb' PERMANENT INTERIOR d F tV ! EXTERIOR 6RILLE5;FDL SPACER BAR;LOW-E 6LA55 AND NEW DEN - BINS 32 INSTALL WINDOW UNIT RELOCATED FROM EXIST. DEN; PROVIDE NEW TEMPERED INSECT SGRIEENS. HARDWARE A5 SELECTED BY OWNER, (T) I. - 6LA55 SASHES d MULL KIT; TO BE MULLED w/ EXIST. WINDOW TO REMAIN AFTER MODEL # INDICATES TEMPERED 6LA55 UNIT PROVIDE I *' 13 RE I 33 3'-0" DOOR TO MATCH AND BE INTE6RATED w/ KITCHEN MILLWORK EXTEN5ION JAMBS AS REQ'D. WHEN LOCATED IN A NET AREA (I.E. SHOWER) PROVIDE PREFIN15HED INTERIOR w/VINYL 1 P EXISTING I5T 4 2ND FLOOR DECK TO EVALUATE STRUCTURAL EXIST. CONTRACTOR TO OPEN U I 34 EXTENSION JAMBS. I AN F _ GLOS_ I O INTEGRITY OF COLUMN/ WOOD POST/ DECK J015T5 d 2x TRIM BOARDS. NOTIFY ARCHITECT NOTE: OF EXISTING CONDITIONS; PROVIDE $10 K ALLOWANCE FOR REPAIR CONTRACTOR TO VERIFY ALL GEILIN6 4 FRAMING HE16HT5 AS WELL AS GABINETRY AND BUILT IN HE16HT5 PRIOR TO77 ORDERING DOORS OR WINDOWS. I GENERAL UTILITY NOTES: 12 3 ___ ___ I I I. THE HVAG CONTRACTOR SHALL VERIFY THE 517E AND DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. - --- --- THENEN REQUIREMEN S TO DETERMINE F(STHE EXISTIN6 AT 255 MAIN STREET SUITE 200 H U N T I N G T 0 N, NY 1 1 7 4 3 -cw - - - - - - - - - - - - I EXIST. EXISTING LIVIN6 ROOM I 5YSTEM(S) WILL BE ADEQUATE TO ACCOMMODATE THE NEW I 8 FOYER I ADDITION. IF THE 5Y5TEM(S) ARE NOT ADEQUATE, THE P. 631.271.5400 Ce WWW.DDANY.NET pyright ©2025 All Rights fleserved. �t 6ENERAL CONTRACTOR SHALL INCLUDE IN HI5 BID THE COST SEAL: PROJECT NORTH: 4 i 7 -- ---- I EL. O-O i OF EXPANDIN6 THE 5Y5TEM(S) A5 REQUIRED FOR PROPER PERFORMANCE. UP I I 2. THE PLUMBIN6 CONTRACTOR TO VERIFY THE 51ZE OF f DN. 22 I EXISTING DOMESTIC HOT WATER SYSTEM AND DETERMINE IF le I I THE EXISTING SYSTEM WILL BE ADEQUATE FOR THE NEW AND I I EXISTING LOADS COMBINED. IF SYSTEM 15 NOT ADEQUATE, i ❑Q THE GENERAL CONTRACTOR SHALL INCLUDE IN HI5 BID THE C05T OF EXPANDING THE SYSTEM AS REQUIRED FOR PROPER NEW a I PERFORMANCE. GARAGE 4 / EXIST. \ I 3. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE 51ZE OF PROJECT TITLE: PORCH I THE EXISTING ELECTRIC SERVICE FOR ADEQUACY IN O'-7 I/2" I PROVIDIN6 NEW ELECTRICAL INSTALLATIONS AS SHOWN. 10 i UPGRADE SERVICE, METER, PANEL, ETC. AS REQUIRED. ALL RENOVATIONS & ALTERATIONS TO THE: z I 2 I \ I z I ELECTRICAL WORK TO BE FIRE UNDERWRITER5 INSPECTED AND APPROVED. SUBMIT CERTIFICATE TO OWNER UPON M c N E I LL RESIDENCE < I I < RECEIPT. THE GENERAL CONTRACTOR SHALL INCLUDE IN HI5 BID THE COST FOR THE UP6RADE AND ALL RELATED I 1 6 I I i Q a 0 �� I ELECTRICAL REQUIREMENTS. - - - - - - - - - - - - - - - - - - - - - - -� 710 OLD MENHADEN ROAD WALL LEGEND CUTCHOGUE , NEW YORK 11935 I N.T.S.4 4 DRAWING TITLE: WALLS/CONSTRUCTION TO BE REMOVED. PATCH/REPAIR ALL FIRST FLOOR PLAN SURFAGE5 ADJACENT TO DEMO WITH MATERIALS TO MATCH `r (' / 5 \ I I I SD AND AL1614 FLUSH WITH EXISTING. NOTES AND DETAILS INSTALL SMOKE DETECTOR AND CARBON N I MONOXIDE DETECTORS IN ACCORDANCE WITH ALL NEW WALL CONSTRUCTION: STATE AND LOCAL CODE REQUIREMENTS. 51NGLE INTERIOR WALLS: U.O.N. `r I AND MULTIPLE STATION SMOKE ALARMS AS PER THE RESIDENTIAL CODE OF NY5 R-314, R-315 AND Y2' GYPSUM WALL BOARD OVER 2"x4" WOOD STUDS ® I6"o.c. 4112" 13'-8" (+/-) 4 T12" AJ801.3.1, WIRED IN SERIES EXTERIOR WALLS: U.O.N. 14'-5" V.I.Fa NOTE: 'HYDRO6AP' HOUSE WRAP AS MANUF. BY BENJAMIN OBDYKE (+/- FIRST FLOOR TOP PLATE TO BE SET 50 NEW SECOND INTERIOR DOOR NOTE: OVER Y2" GDX PLYWOOD OVER 2"xb" WOOD STUDS ® I6" o.c.W/ 5V2" R-21 GATT INSULATION AND Y2° GYPSUM WALL BOARD. FLOOR ALIGNS w/ EXIST. (V.I.FJ PROVIDE AND INSTALL SOLID GORE 13/8' PRE HUN6 PRIMED DRAWN BY: 5DE SHEET NO. INTERIOR DOORS STYLE 4 STICKING TO MATCH EX15TIN6. 5UBFLOOR NOTE: NOTE: PROVIDE AND INSTALL DOOR HARDWARE TO MATCH EXISTING. NEW FOUNDATION WALL CHECKED BY: 5,15 WHERE NEW F.J. AND EXIST. F.J. MEET, 5UBFL00R 15 TO PREP 4 PAINT ENTIRE INTERIOR GEILIN6,5/ WALL5/ TRIM IN DOORS ADJACENT TO INTERIOR AND EXTERIOR CORNERS STRADDLE POINT OF BEARING (TYPJ OWNER SELECTED COLORS SHALL BE SET 4 y2" TO R.O. TO ALLOW FOR OWNER SELECTED EXI5TIN6 WALL CONSTRUCTION TO REMAIN DATE: 10.20.25 l 04 F21RI57 TRIM. DOORS FOR CLOSETS, LINEN CLOSETS, PANTRIES ETC. a r-LOORFLA EE E: NOTE: SHALL BE CENTERED WITHIN WALL LENGTH U.O.N. EXISTING WOOD FLOORS ARE TO BE SANDED AND REFINISHED NOTE. SCALE: A5 NOTED DIMENSIONS TAKEN TO FIN15H MATERIALS - GYP. IN OWNER SELECTED COLOR WATER BASED FINISHES ARE TO MIN. TRIM ALLOWANGE- PAINT GRADE TO MATCH EXISTING (NO ALL 6YP5UM WALL5 AND GEILIN65 ARE TO BE TAPED AND 5PAGKLED (THREE ,4IO4 I/4" = I'-0" 8 PLYWOOD BE USED. MDF TRIM): COATS) AND PAINTED WITH ONE GOAT PRIMER AND TWO GOATS FINISHED COLOR PROJECT N0. 2515 -3Y2" DOOR 4 WINDOW CASING AS SELECTED BY OWNER. PROVIDE WATER RESISTANT 6YP5UM WALL BOARD IN -5Y2" BASE w/ SHOE MOULDING ALL DAMP/ NET LOCATIONS. CON57RUC71 ON MOTES77 THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY- LINE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE,AND ARE AND SHALL 1 LINE OF WALLS BELOW REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE 2 LINE OF ROOF ABOVE SHOWN DOTTED (TYPa ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. O LINE OF CEILIN6 TRANSITION IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I 4 ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING PATCH AND REPAIR WALL TO MATCH AND ALIGN w/ EXIST. ADJACENT ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION'ALTERED BY FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE T 5 RELOCATED ATTIC AGCE55 PULL DOWN STAIR, DBL. G.J. CONSTRUCTION AROUND OPENING SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION i � I LAW ARTICLE 147-ARCHITECTURE,SECTION 7307) RELOCATED WINDOW UNIT FROM HALLWAY; PROVIDE NEW GA51N6 TO MATCH EXISTING O6 ISSUANCE: RELOCATED WINDOW UNIT FROM EXISTING LAUNDRY ROOM; PROVIDE NEW CASING TO O MATCH EXISTING N0. DATE: DESCRIPTION: O FURR OUT WALL A5 REQ'D. TO ACCOMMODATE SHOWER NICHE AND AL16N w/ 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING i 8 ADJACENT A5 SHOWN O9 REMOVE EXIST. SIDING d SHEATHING; GAT ® MID-SPAN PROVIDE Y2" GYP. BD. I 10 PROVIDE AND INSTALL OWNER SELECTED CLOSET 5Y5T EM I D PROVIDE AND INSTALL CHROME HANGING ROD AND SHELF CDPATCH AND REPAIR WOOD FLOORING A5 REQ'D. (TYP. OF AREA OF WORK, EXCLUDING BATHROOMS) I i 13 PROVIDE AND INSTALL NEW WOOD FLOORING TO MATCH EXISTING; FINISH w/ OWNER SELECTED WATER BASED FINISHES I I _ _ _ _ _ _ _ _ 14 PROVIDE AND INSTALL OWNER SELECTED TILE FLOORING AND WALL TILE IN WET AREAS I 5-6" 15 OWNER SELECTED 36" VANITY WITH LAV SINK (5EE PLUMBING FIXTURE SCHEDULE) i I 1? 20 16 OWNER SELECTED 30" VANITY WITH LAV SINK (SEE PLUMBING FIXTURE SCHEDULE) I ' OWNER SELECTED 48" VANITY WITH LAV SINK (SEE PLUMBING FIXTURE SCHEDULE) CONTRACTOR TO OPEN UP EXISTING I5T 4 2ND FLOOR DECK TO EVALUATE STRUCTURAL p NE I O INTEGRITY OF COLUMN/ WOOD POST/ DECK J0I5T5 d 2x TRIM BOARDS. NOTIFY ARCHITECT OF I I ' BATH `{ 15 EXISTING CONDITIONS; PROVIDE $10 K ALLOWANCE FOR REPAIR A-300 l 23 #3 12 g�h}�5 i--- I 19 OWNER SELECTED TILE SHOWER PITCHED TO DRAIN; COORDINATE OWNER REQUIREMENTS 2'4"xb'8' 14 0 23 I�--�I 21 FOR PLUMBING ACCESSORIES;SEE PLUMBING FIXTURE 50HEDULE I - ' l i 1� RENO. 20 OWNER SELECTED TEMPERED GLASS SHOWER SURROUND 24 BEDROOM #3 4'-II 1/8" (EQ) 4'-II 1/1 (EQ) d I i BALCONY 21 42" H16H WALL TO BE GAPPED w/ OWNER SELECTED MATERIAL 4 TEMPERED GLASS Q 20 I SHOWER SURROUND I m t 10 RENO. 18 WALK_. I 22 REPLACE EXISTING WINDOW SASH w/ TEMPERED UNIT x _ GLO5. 7 16 j - - - - - - GD PROVIDE BATHROOM EXHAUST FAN VENTED TO EXTERIOR =_- NEW IO z- _ - _ - --� \ 5D I / K-IN 0 LG O5. 24 NEW WINDOW IN EXIST. WINDOW LOCATION -I= —_ - — -- ---- - - - - - - - - - � z- - - - - a3 — � — - - — — — — — — — — — I 2 61 " - 6'-6"--=--4 I/2" 6'-5 1/2" Q1-7 \ STRUCTURAL KUROS SORBI-AVA ENGINEERING 5 r - - T - - AL N Sp 12 z ENGINEER: 169 COMMACK ROAD SD I \ 0 I I SUITE H-362 --- - - 7 4 I ALIGN EEi6'1 COMMACK, NY RENO, L - - - - - 631-355 5556725 O II 2 BEDROOM #1 CLO5. '� // No 715N I \ I I (2) 2'b"xb'8" I / / 2 BATH #4 48Ia�SD EXIST. HALLI % ��� \\B TH #2/ �\ 20 i rn-�I� 2 9 EX15T I is \ INJ I6 . ON. \ LNNN_JJJJa++ I � I Y I - - - - - - - - - - - -- - - - 23 \ 23 16H7/\/EN7 CALCULA71 ONS N I NEW / � ITS -1- - - - - - - - - - - - - - - - - - � � I BEDROOM #4 --- -- cv I A. 14 NEW BEDROOM #4 REQUIRED L16HT TRANSMITTING AREA 5'-0"I I I AREA = 182.6 SQ.FT. 182.E SQ.FT. X 8% = 14.6 SQ.FT --- _-- -- / I i MOP05ED WINDOW L16HT TRANSMITTING AREA=30.9 5Q.FT. REQUIRED AIR VENTILATION AREA = 12 I I PROPOSED WINDOW AIR VENTILATION 1-1 5Q.FT. DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. I 4 -- 1 I -0 4 I/2 - i RENO. I BEDROOM #2 cv I I I NEW 4 RENO, REQUIRED L16HT TRANSMITTING AREA = 255 MAIN STREET SUITE 200 H U N T I N G T O N, N Y 11743 1 '! ! I, BATHROOMS NOT REQUIRED WHERE ARTIFIGIAL L16HT I5 PROVIDED P. 631.271.5400 WWW.DDANY.NET Copyright ©2025 All Rights Reserved. REQUIRED AIR VENTILATION AREA = SEAL: PROJECT NORTH: ! Ili !I ( TVy3 2 I? r NOT REQUIRED WHERE LOCAL EXHAUST 15 PROVIDED d) EQ. EQ' ► I -- -- I � l 1 I F l b I I 2 2 NOTE: r cv I 1 I DOOR R.O. TO BE SET 4f'2' OFF OF INTERIOR 13'-10 1/2" 1 RNO. I I I I AND EXTERIOR CORNERS TO PROVIDE ROOM FOR OWNER SELECTED TRIM. MIN. TRIM ALLOWANGE- PAINT GRADE AS I I 3 I SELECTED BY OWNER: I LI { - - - - - - - - - -I- - - - - - - - - - - - J -3YY DOOR 4WINDOWGA5ING I � 11 22 -5 Y2" BASE w/SHOE MOULDING 11 III ! II PROJECT TITLE: I 1 III,,; !'I,I I! _---._-- � ( G = INSTALL SMOKE DETECTOR AND CARBON RENOVATIONS & ALTERATIONS TO THE: Di - ! jl l I I -- I MONOXIDE DETECTORS IN ACCORDANCE WITH ALL STATE AND LOCAL CODE REQUIREMENTS. SINGLE AND MULTIPLE STATION SMOKE ALARMS AS PER M c N E I LL RESIDENCE THE RESIDENTIAL CODE OF NYS R-314, R-315 AND AJ801.3.1 WIRED IN SERIES 710 OLD MENHADEN ROAD WALL LEGEND CUTCHOGUE NEW YORK 11935 ' ! N.T.S. I I l ,�I ! I I, �I '� DRAWING TITLE: � ;! '' ; I �; ! � j I , I I - WALLS/CONSTRUCTION TO BE REMOVED. PATCH/REPAIR ALL ! I I l II I SURFACES ADJACENT TO DEMO WITH MATERIALS TO MATCH SECOND FLOOR PLAN -_ _ ! i AND AL16N FLUSH WITH EXISTING. II NOTES AND DETAILS II - _ i i NEW WALL CONSTRUCTION: l 1 INTERIOR U.O.N. -`- - --- - j Y2" 6YPSUM WALL BOARD OVER 2'l WOOD 5TUD5 ® 16"o.c. -- -- -- - -------- ---- - EXTERIOR WALLS: U.O.N. 'HYDR06AP' HOUSE WRAP A5 MANUF. BY 13ENJAMIN OBDYKE NOTE. OVERY2" COX PLYWOOD OVER 2"xb" WOOD STUDS ® 16" o.c. PREP � PAINT ENTIRE INTERIOR CEILINGS/ WALLS/ TRIM IN OWNER SELECTED COLORS W/ 5(/2' R-21 BATT INSULATION AND Y2" GYPSUM WALL BOARD. DRAWN BY: 5DE SHEET NO. NOTE: NEW FOUNDATION WALL EXI5TIN6 WOOD FLOORS ARE TO BE SANDED AND REFINISHED NOTE: CHECKED BY: 5_J5 IN OWNER SELECTED COLOR. WATER BASED FIN15HE5 ARE TO PROVIDE 22"x30 AGCE55 INTO EXIST. ATTIC EX15TING WALL CONSTRUCTION TO REMAIN BE USED. SPACE ROUGH NEW ATTIC DATE: 10.20.25 AS 5EC0N1:) -1 5 r—LOOR FLAN SUBFLOOR NOTE: NOS: NOTE: SCALE: AS NOTED WHERE NEW F.J. AND EXIST. F.J. MEET, SUBFLOOR IS TO ALL DIMENSIONS TAKEN TO FINISH MATERIALS ALL GYPSUM WALLS AND CEILINGS ARE TO BE TAPED AND SPAGKLED (TFIREE A105 I/4" = i'-0" STRADDLE POINT OF BEARING (TYP) - GYP. BO. 8 PLYWOOD COATS) AND PAINTED WITH ONE GOAT PRIMER AND TWO GOATS FINISHED COLOR PROJECT NO. 2515 AS SELECTED BY OWNER. PROVIDE WATER RE515TANT 6YP5UM WALL BOARD IN ALL DAMP/ WET LOCATIONS. i CON57RUC71ON N07ES E]Y' 71 THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE,AND ARE AND SHALL 1 ROOF CON5TRUGTION REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE - 5/8" COX PLYWOOD 5HEATHINC6 INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER — IQ" WIDE FELT PARALLEL TO EAVES LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE — 36 WIDE STARTER STRIP OF WEATHER WATCH (MIN. REFER TO ROOFING ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL NOTE #I ON A-100)— (1) # 30 FELT UNDERLAYMENT COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. — LIFETIME ARCHITECTURAL A5PHALT SHINGLES TO MATCH EXISTING IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I CONT. LOW PROFILE RIDGE VENT. RIDGE VENT SHALL BE SHINGLE VENT ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING _ 2 I I A5 MANUFACTURED BY 'AIR VENT' ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION"ALTERED BY' FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION O3 SUPPLY 36" WIDE WEATHER WATCH VALLEY FLASHING IN ALL VALLEYS (TYPE LAW ARTICLE 147-ARCHITECTURE,SECTION 7307) O4 LINE OF WALL BELOW (TYPJ ISSUANCE: I NO. DATE: DESCRIPTION: OS WEAVE NEW ROOF 5HIN6LE5 INTO EXIST. 1. 10.20.2S ISSUED FOR BUILDING DEPARTMENT FILING O PROVIDE LAY—ON ROOF OVER VALLEY CREATED WHERE NEW ROOF MEETS I EXISTING FOR PROPER DRAINAGE (MIN. 3 PITCH) OPATCH AND REPAIR EXI5T. ROOF A5 REO'D. - - - - - - - - - - - - - I i II I itI I ; � II II I I - - - - - - - - - - - - - - - I � II I II I II II A-300 I I I II I � II II II II II 1 I II 4 II II I � it II II r -- L - -- - - -1 A- 3 I I STRUCTURAL KUROS SORBI—AVA ENGINEERING -- — -- — -- I I ENGINEER: 169 COMMACK ROAD I SUITE H-362 - - - - - - - - - - - - - - -I I I COMMACK, NY 11725 —1 I 631-355-5556 I II II - - - - - - .r \ - - - - - - - - - - - - - - - - _ I II I I I N I 3 I I II I DIVERSIFIED DESIGN ASSOCIATES — ARCHITECTS, P.C. I 5 I I 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 P. 631.271.5400 WWW.DDANY.NET Copyright ©2025 All Rights Reserved. / II SEAL: f PROJECT NORTH: I I I I i INSTALL NEW PLUMBING VENTING SYSTEM. IL A I I I INSTALL AT LOCATION ABOVE ROOF. ; L - - - - I I I — _I T TIONS ARE TO COMPLY w/ — — — — — — — — — _ _ _ _ _ — — J THE NY5 RESIDENTIAL GODE4 NYS PLUMBING CODE. \ L PROVIDE WEATHERPROOFING ROOF I 3 I I 4 JACK W/ NEOPRENE GASKET PROJECT TITLE: - AROUND VENT. RENOVATIONS & ALTERATIONS TO THE: z I j 1,1 _ McNEILL RESIDENCE Q FLASHING ® ROOF. --- , 14 710 OLD j MENHADEN CUTCHOGUE NEW D W YORK11935 l it I ( I III it i i ! i s t I DRAWING TITLE: ROOF PLAN NOTES AND DETAILS ROOF VENT DETAIL i INSTALL ROOFING SHINGLE 5Y5TEM TO LAP OVER DRAWN BY: SDE SHEET NO. FLASHING ® 51DE-5 AND TOP. CHECKED BY: SJS DATE: 10.20.25 �i0Of FLAN 2 ROOF: VENT 17)ETAIL NOTE: SCALE: AS NOTED Aml 06 VENT TERMINAL TO COMPLY WITH NY5 5EGTION A106 N.T.5. P3103.2 4 P3103.1.1;5EE A-100 PROJECT N0. 2515 ., !"RAMIN6 NOTES - THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY Ol LINE OF ROOF ABOVE SHOWN DOTTED (TYPa THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE,AND ARE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE O P05T FROM ABOVE TO BEAR 50LIDLY ON HDR. SHOWN DOTTED (TYPa INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL 3 P05T FROM ABOVE TO BEAR 50LIDLY ON 61RDER/ FDN. BELOW (TYP) COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION O4 PROVIDE 50LID 4x4 POST IN HALL UNDER HDR. ABOVE OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING S ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION"ALTERED BY'PROVIDE SOLID bxb P05T IN WALL UNDER HDR. ABOVE FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION (DPROVIDE 4x6 PARALAM P05T IN WALL UNDER HDR. ABOVE LAW ARTICLE 147-ARCHITECTURE,SECTION 7307) 7 SET TAIL TO ALIGN w/ ADJACENT (SEE ELEVATIONS) ISSUANCE: NO. DATE: DESCRIPTION: O8 ATTACH F.J. TO HDR. ABOVE w/ 'SIMP50N' (HU210) 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING EXIST. O DECK NEW 3Y2" 5GH. 40 5TL. P05T HDR. ABOVE TO BEAR SOLIDLY ON FDNJ GIRDER BELOW; PROVIDE 9(NO WORK)) 7"x8"x YY 5TL. GAP PLATE FOR FULL BEARING; SECURE 5TEEL BEAM w/ (4)YY DIA. BOLTS *EL. (-)I'-3 1/2" 10 PACK 5TL. BEAM SOLID w/ 2x A5 REQ'D. FOR J015T ATTACHMENT 11 EXIST. ATTACH 2x6 G.J. TO BOX BM. w/ 'SIMP50N' (HU26) 1 ELNPATIO 12 ATTACH FLU5H HDR. TO FLU5H HDR. w/ 'SIMPSON' (HU51.81/l0) )Q)"`6R3/4° 13 ATTACH EX15T. FLUSH HDR. TO FLUSH HDR. w/ 'SIMP50N' (HU210-2) pN G VERIFY IN FIELD AND NOTIFY ARCHITECT OF ANY DI5CREPANGIE5 I I 5 (2) 2AO (2) 2x10 _EXIST. FLUSH HDR. HDR. HDR. (2) 2AO HDR. TO REMAIN — 1 ON. Q III a � I III A-300 O 8 U- O v I I x I X0 III W EXIST. EAT-IN HOME OFFICE PORCH EXIST. 2x10 F.J. NEN ' �j AREA (NO WORK) I I I ® 16 O.G. -�. I I I I � 1 w 12 x 8 III — _ - - - - - - a- - 2 m I to a III I II F_ �_ 2 III W8x28 FLU5H HDR. RENOVATED 4 8 O Q KITCHEN N p 3 O � A - EX15T. 2x10 F.J. 13 �i ® NEW LAUNDRY j ® ® (b" O.G. STRUCTURAL KUROS SORBI-AVA ENGINEERING ENGINEER: COMMACK ROAD Lu SUITE H-362 ^y 2x10 LEDGER BD. 169�- t� COMMACK, NY 11725 O O REND 631-355-5556 x DINING ROOM N \Z — OWNER'S N ® G 05ET QC X Lu pi Q RENO. Q t_v I BATH #1 —i Xi :., — NEW DEN u- O I - - - - - ' x x — v N ® I EXIST. I I I I m G o5. 1 1 1 1 1 ti 4 A I ' I I III 1 I -- 6 I --- I I 1 I Jill (2) 13/4"xa Y4"" L.V.L. IN I' 9" 5TL. PLT. I --- -- I I U- `j 1 1 1 1 1 © FLUSH HDR. --- - O 1 1 1 —UNDER WALL ABOVE --- -- � I I X O DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 EXI5T.:o 1 Copyright ©2025 All Rights Reserved. --- --- EXI5TIN6 I I �i ® LIVING ROOM 1 1 1 1 1 P. 631.271.5400 WWW.DDANY.NET E .0-0 I I (NO WORK) 1 1 1 1 1 SEAL: PROJECT NORTH: r " 1 1 I �I I EXIST. 2x6 G.J. � 1 Q I — —-j ON. EX15T. 2x8 R.R. N I I 1 I 1 I ® 16" O.G. NEW 6ARA6E D; 1 \0 � IY v v U EXIST. 1 I I �e- O � O cx PORCH I I 1 I PROJECT TITLE: (No woRK) III 1 RENOVATIONS & ALTERATIONS TO THE: z 1 0 �1 <,�ro�\max ® w IS ® REMAIN R. TO H Lu 1 _TO I.I 1 McNEILL RESIDENCE — — -- EXT. (2) 2x10 D R 1 __- �-- - - - N- _ - _- - - - - - - - - - - - - E IST �2T2x10 MXIITI A 1 — — — — — — — — — — — — — — — I - - - - - - - - _ - -- 4 2x6 G.J 14 710 OLD MENHADEN ROAD I 1 CUTCHOGUE , NEW YORK 11935 2x8 R.R. ® I6 O.G. 2x8 R.R. 1 4 I6 NOTE: DRAWING TITLE: N r " O.G ® I6" O.G. .11¢ • �� I 1 ALL EX15T. MEMBER5 ARE A55UMED; NOTIFY ARCHITECT OF ANY D15GREPANGIE5 UPON DEMOLITION SEGONID FLOOR FRAM I NG I 2 ' � - I NOTES AND DETAILS NOTE: 1 O (2) 2x12 HDR. 7 1 PROVIDE ALL 'SIMP50N' JOI5T HAN6ER5 A5 REQV. PROVIDE CONGEALED HAN6ER5 - - -� WHERE REQUIRED. - - - - - - - - - - - - - - - - - NOTE: ALL P05T5 SHALL CON515T OF (1) KIN6 5TUD 4 (2) JACK 5TUD5 U.O.N. ,5TA N=�A I:) Hr=A�ER 6L) 11:)E DRAWN BY: 5DE SHEET NO. (NOTE: ONLY APPLICABLE FOR HEADER5 NOT GALLED OUT ON DRAWIN65) CHECKED BY: 5J5 MAX. SPAN HEADER SIZE I S GON1� f=L00RI=RAMIN6 FLAN 2'-0rr (2) 2x6 D.F. #2 DATE: 10.20.25 3'-0r (2) 2x8 D.F. #2 4-0�r (2) 2AO D.F. #2 SCALE: AS NOTED Aml 07 6-01r (2) 2x12 D.F. #2 8'-0" PROJECT N0. 25i5 (2) 1 3/4"x 9 1/4" L.V.L. 10.-0'. (2) 1 3/4"x II 1/4" L.Y.L. i i r-RAM I N6 NOTES _ THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY 1 LINE OF ROOF ABOVE SHOWN DOTTED (TYPa THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE,AND ARE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER 2 LINE OF WALL BELOW (TYPJ LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL 3 PROVIDE SOLID 4x4 POST IN WALL UNDER HDR. ABOVE COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION 4 OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I ATTACH EXIST. G.J. TO NEW FLUSH HDR. w/ 'SIMPSON (HU28) ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION"ALTERED BY' S SET TAIL TO ALI6N w/ ADJAGENT (SEE ELEVATIONS) FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE - -- - - SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION i LAW ARTICLE 147-ARCHITECTURE,SECTION 7307) i ISSUANCE: NO. DATE: DESCRIPTION: i 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING I i I i i i I I 2 - I - - - - - II I I - - - - - fi - - - - - - - - - - - -I - - - _- - — - - � --- (2) 2x8 HDR. I I I I I I NEW BATH #3 A-300 I d) v I x � I v v � p - I EX15T. Q O EXIST. NEW v RENO. ® I BALCONY BEDROOM #3 WALK-IN `? WALK-IN uj - O N- C O5. x 01-05• x ® RENO. x X ® x BATH #5 Lu C2 I ry 4 x ® 3 I 3 —I— — — x \ I 2)12x8 GONT FLUSH HDR. I \ I I J_-_ =__ -- _ _--_---- _ / I 4 4 I --� __- ----_ 1_ _ _ _ _ I \ I STRUCTURAL KUROS SORBI-AVA ENGINEERING - + -- - -- -- - I I- / ? U H? I I ENGINEER: I v v 169 COMMACK ROAD I - - P - _ - - I I SUITE H-362 (2) 2x8 HDR. T- � �� I x � x dJ� - -- — —('O �c ® u cxv ® COMMACK, NY 11725 x \ x O x O NO• - - - - - _ 631-355-5556 GLOS• 2x8 R.R. - N BEDROOM #I /� i ® I6"I O.G T ® i \\ �( I x �, x x NEPq I \ w w RENo. O Lu Q ?+�o EIST.4 ALL BATH #4 B� #2 I X � �L-4}.. �EU. a'-I I I/8" 311 3 (2) 13/4" 7 y4" 2 I '1 L.V.L. F�LSH 3/4"x Y" HQP I .V.L. FLM4 HDR 3�4'X a Y4" L.V.L. R.B.� i — — — NEW # � � --- -- / I LE] ❑ 4 3 - - - - - - J BEDROOM 4 Lj o --- -- / --- -� EXIST. 12x8 G.J. DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 ® I6�' O.G. I P. 6 31.2 71.5 4 0 0 WWW.DDANY.NET '(2) � ,3�4'X'Y4"(L.L.V. HDR.I II' �/ — -- I I RENO. BED # I I Copyright ©2025 All Rights Reserved. OOM 2 I I SEAL: PROJECT NORTH: EX15T. x8 R.R. EX15T. 2x8 F .R. ® 16" O.G. I ® I6" adI � 5 R�NO. I I I I Coos. I I I II I I — — — — — — - - I- - - - - - - - - - - - - - - - :. Ii II 2 I I ,,; I' I I I PROJECT TITLE: I ' Il; j I I RENOVATIONS & ALTERATIONS TO THE: - - - - � McNEILL RESIDENCE �10 OLD MENHADEN ROAD I CUTC rnRAw NHOGUE , NEW YORK 11935 NOTE: i III I I I ALL EX15T. MEMBER5 ARE A55UMED; NOTIFY ARGHITECT OF ANY D15GREPANGIE5 UPON DEMOLITION !''i I - _ - I ROOF FRAMING PLAN !I I � I NOTE: NOTES AND DETAILS LI _ - -_ - _ - -_ ___ — ,' J PROVIDE ALL 'S1MP50N' JO15T HAN6ER5 A5 REOV. PROVIDE CONGEALED HAN6ER5 -=- - --=--- -- _-- _ -- --- -- I WHERE REQUIRED. NOTE: ALL PO5T5 5HALL C-ON515T OF (1) KIN6 5TUD d (2) JACK 5TUD5 U.O.N. . 5TA N Z�A =� Hr=A�ER 6UI �r= DIRAWN BY: 5DE SHEET NO. (NOTE: ONLY APPLIGABLE FOR HEADER5 NOT GALLED OUT ON DRAWINGS) CHECKED BY: 5JS MAX. SPAN HEADER SIZE '2-O" I (2) 2x6 D.F. #2 DATE: 10.20.25 FIV4 Al 08 001= f=RAMIN6 FLAN 4-011 (2) 2x8 D.F. #2 e - ,4108 I/4" = I'-0" � '�r (2) 2x10 D.F. #2 SCALE: AS NOTED (2) 2x12 D.F. #2 PROJECT NO. 2515 81-0" (2) 1 3/4"x q 1/4" L.Y.L. 10'-0" (2) 1 3/4"x 11 1/4" L.V.L. r, ROOF CONSTRUCTION NOTES: NEW ROOF CONSTRUCTION THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY GONT. LOW PROFILE RIDGE VENT. RIDGE / / - /e" GDX PLYWOOD SHEATHING THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE,AND ARE AND SHALL _ REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE VENT SHALL BE SHINGLE VENT II AS INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER MANUFACTURED BY 'AIR VENT' / / - 36" HIDEISTARTER STRIP OF EAVES WATCH (MIN. REFER TO LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE ROOFING NOTE #1 ON A-100) ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL - (1) 30 LB. FELT UNDERLAYMENT COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. / I —LIFETIME WARRANTY ASPHALT ROOF SHINGLES TO MATCH EXIST. IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING 36" WIDE WEATHER WATCH VALLEY - 00 FLASHING IN ALL VALLEYS (TYP) INA�LL CONSTRUCTION NOTES: ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION"ALTERED BY" Jl.J FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE NEW WALL CONSTRUCTION SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION O / / �2" GYP. BD. LAW ARTICLE 147-ARCHITECTURE,SECTION 7307► -2"xb" WALL STUDS ® 16" O.G. w/ R-21 BATT INU5L. IL O / / - 1 'HYDROGAAP'' HOU5ETMWRAP A5 MANUF. BY BENJAMIN OBDYKE ISSUANCE: lLu _ 6 :VINYL 5 DING TO MATCH EXIST N0. DATE: DESCRIPTION: - - - 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING o / / / / -- _ —;-- - =f-' TRIM AND FA501 A NOTES: z - - --_ --- _ -- -- -- _-_;- ---_---- FASCIA: 2x 5UB-FA5CIA WRAPPED w/ WHITE ALUM. UNDER NEW Lu ---- __ GUTTERS (TYP)- - __ _ �' FLYER: Ixb 'VERSATEX' TRIM BD. OVER 2xb FLYER (TYP) u al ® j EH I X15T. SECOND F/OOR LATE EIGHT EL: 17'-11 1/2" _- _ -� _ - -- - -- _ --�__ _ CORNER BOARDS: CORNER BOARDS TO MATCH EXISTING WINDOW SURROUNDS: VINYL WINDOW SURROUND TO MATCH EXISTING l z zi lu SOFFIT: VINYL VENTED BEAD BOARD SOFFIT TO MATCH EXISTING 1�04, E PROVIDE AND INSTALL 5" WIDE GUTTERS AND LEADERS TO BE TIED INTO EXIST. DRYWELL (TYPJ zLai- DOO tY I zriY I WEAVE NEW ROOFING = EXISTING WINDO INTO EXIST. (TYP) Q W1 R N = NEW WINDOW ,EXIST. SECOND FLOOR HEIGHT EL: a'-II I/8" RELOCATED WINDOW . _ . 1 - --: =- PROVIDE ROOF TO WALL FLA5HIN6 8 51DENALL STEP FLASHING AS REQ'D. I -O 0-0" (TYP) E 111E a ®® ®M ® m mmI� LM E E E E 10E OWNER SELECTED LIGHT FIXTURE WIRED aTO SWITCH (TYP) M � MM ❑ E E PAR6E EXPOSED FDN. AS REQ'D. TO 1110 MATCH EXIST. (TYP) — M L== 110 4 EXIST. FIRST FLOOR HE16HT EL: 0'-0" EXIST. AVG. GRADE EL•.(- I'-9 2° ; 1 1 1 1 I 1 1 1 1 1 I 1 I I 1 I 1 20' 1 /'� 1 I I O I 1 I I ; 21'-10 1/2" rT -------- ----------------------------------------------------------------L--, I ; I 1 I I I 1 1 I I I 1 1 I I I r _____________ ------T____________________________________-____ 1 1 I I I 1 ' 1 STRUCTURAL KUROS SORBI-AVA ENGINEERING LINE OF FOUNDATION/ FOOTING SHOWN i I ENGINEER: 169 COMMACK ROAD DOTTED (TYP) L----; ---------- SUITE H-362 ' COMMACKI NY 11725 631-355-5556 I I 1 1 1 I I I I 1 I PROVIDESTEP FOOTING AT 2'-0" MAX. --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- HORIZONTAL AND V-O" MAX. VERTICAL ALIGN \ \ I FRONT ELEVATION A<200 im, = v-o" (SOUTH ELEVATION) c, . I \ \ I I A-300 \ \ CONT. LOW PROFILE RIDGE VENT. RIDGE VENT SHALL BE SHINGLE VENT 11 AS MANUFACTURED BY 'AIR VENT' \ \ z � \ \ O O I� DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. IO 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 \ \ O P. 631.271.5400 WWW.DDANY.NET \ \ w Z Copyright ©2025 All Rights Reserved. - - -=_- SEAL: PROJECT NORTH: EXIST. SECOND FLOOR PLATE HEIGHT EL: 17'-II I/2" z U ® r ri ALIGN I 11 A —1 CONTRACTOR TO OPEN UP EXISTING 15T E R E E 0 2ND FLOOR DECK TO EVALUATE E ®u ` \ aw a STRUCTURAL INTEGRITY OF COLUMN/ WOOD ®r ®� '** POST/ FY ARCHITECT EXIS IM BOARDS. ING NOTIFY OF Lv \ \ CONDITIONS; PROVIDE $10 K ALLOWANGE ------ ------------------- ----------------------------- ------------- I I FOR REPAIR PROJECT TITLE: T. SECOND FLOOR HE16HT EL: a'-II Va° _ _ RENOVATIONS & ALTERATIONS TO THE: PROVIDE ROOF TO WALL FLASHING 4 McNEILL RESIDENCE 51DEWALL STEP FLASHING AS REQ'D. (TYP) I i 710 OLD MENHADEN ROAD 16"xb" GRAWL SPACE VENT w/ INSECT CUTCHOGUE , NEW YORK 11935 E *, N SCREEN E � iE._ Jl�.l E _ DRAWING TITLE: ®® Lr � EXTERIOR ELEVATIONS _]E 71,r7 r1 I I ° PAR6E EXPOSED FDN. AS REQ D. TO 11 IL T MATCH EXIST. (TYP) SEXIST. FIRST FLOOR HEIGHT EL: 0-0 �� I I f =4 LINE OF FOUNDATION/ FOOTING SHOWN EXIST. AV6. GRADE DOTTED (TYP) • z I I I I EXI5T. 1 NEW 201-011 DRAWN BY: 5DE SHEET NO. I I I I I I I I O I I 1 I 1 m ;------ --; 21'-10 1/2" I I I I I CHECKED BY: 5J5 I I I I I I I I I I I I 1 I I 1 1 1 1 I I I I I 1 I--------- DATE: 10.20.25 e I I I I I 1 1 1 ; I I I 1 I I I I I I 1 ---------J ;----� A200 SCALE: Ac5 NOTED II I I L------------------------------------------------------J F---- --J ------1 2 IREAR ELEVA71 Oil --------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------ ----------------�' ROVIDE STEP FOOTING AT 2'-0" MAX. PROJECT N0. 25I5 1 I 1 I A200 im, = r-0" (NORTH ELEVATION) IAL16NI HORIZONTAL AND I'-O" MAX. VERTICAL i ROOF CONSTRUCTION NOTES: NEW ROOF CONSTRUCTION THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY - /8 COX PLYWOOD SHEATHING THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECTS SERVICE,AND ARE AND SHALL CONT. LOW PROFILE RIDGE VENT. RIDGE 5 REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE VENT SHALL BE SHINGLE VENT 11 AS - IQ" WIDE FELT PARALLEL TO EAVES INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER MANUFACTURED BY 'AIR VENT' - 3b" WIDE STARTER STRIP OF WEATHER WATCH (MIN. REFER TO LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE ROOFING NOTE #1 ON A-100) ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL - (1) 30 LB. FELT UNDERLAYMENT COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. -LIFETIME WARRANTY ASPHALT ROOF SHINGLES TO MATCH EXIST. IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I 36" WIDE WEATHER WATCH VALLEY ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING WALL GONSTRUGTI ON NOTES: ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION"ALTERED BY FLASHING IN ALL VALLEYS (TYP) FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE NEW WALL CONSTRUCTION SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION -- ---__-_ _ Y2" GYP. BD. LAW ARTICLE 147-ARCHITECTURE,SECTION 7307) -`�`— -- - - -2"xb" WALL STUDS ® 16" O.G. w/ R-21 BATT INU5L. Y2" GDX WALL SHEATHING ISSUANCE: -'HYDROGAP' HOUSE WRAP AS MANUF. BY BENJAMIN OBDYKE - =-- 12 NO. DATE: DESCRIPTION: -SIDING :VINYL SIDING TO MATCH EXIST. PATCH AND REPAIR SIDING TO MATCH 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING AND ALIGN w/ EXIST. ADJACENT (TYP) TRIM AND FASCIA NOTES: -- - FA5GIA: 2x 50-FA50IA WRAPPED w/ WHITE ALUM. UNDER NEW =' = PROVIDE ROOF TO WALL FLASHING 4 GUTTERS (TYPJFLYER: Ixb 'VERSATEX TRIM BD. OVER 2xb FLYER (TYP) ,EXIST. SECOND FLOOR PLATE HEIGHT EL: 17'-II 1/2" — _ SIDEWALL STEP FLASHING AS REQ'D.`_� 51DE CORNER BOARDS: CORNER BOARDS TO MATCH EXISTING - _ WINDOW 5URROUN05: VINYL WINDOW SURROUND TO MATCH EXISTING ALIGN I'-b"± _ ��-6"± SOFFIT: VINYL VENTED BEAD BOARD SOFFIT TO MATCH EXISTING PROVIDE ROOF TO WALL FLASHING 4 ®rpm CONT. LOW PROFILE RIDGE VENT. NOTE: 51DEWALL STEP FLASHING AS REQ'D. RIDGE VENT SHALL BE SHINGLE PROVIDE AND INSTALL 5" WIDE GUTTERS AND LEADERS TO BE (TYPJ N1 ® VENT II A5 MANUFACTURED BY'AIR VENT' TIED INTO EXIST. DRYWELL (TYPJ ----------------------- -------- Q = EXISTING WINDOW/ DOOR LINE OF EXIST. ROOF SHOWN DOTTED NN = NEW WINDOW a 12 EXIST. SECOND FLOOR HEIGHT EL: '-II I/8" - ' - _ _ _ ® = RELOCATED WINDOW — . — . — . — . — . — . — . — -O' - '-0 I'-611 1jW Lj -A to � E�J ALIG Or E Liu 17 7117 CEni 17 PARGE EXPOSED FON. AS REQ'D. TO O - � ' rr MATCH EXIST. (TYP) SEXIST. FIRST FLOOR HEIGHT EL: 0'-0" — . — . EXIST, AVG. GRADE E -)II_a y211 - - - - - - - ------------- I I I I z NEW EXIST. EXIST. NEW 16"xb" GRAWL SPACE VENT w/ INSECT ------------ --- ----------------------------------------- SCREEN p -------------------------------------------------------------------------- m = I I --------------------------------------------------------------------- I I I STRUCTURAL KUR0 RING LINE OF FOUNDATION/ FOOTING SHOWN -- ---- ;-------- ; ALIGN ALIGN ENGINEER169 CCOMMACK ROAD DOTTED (TYPJ ------ --- I SUITE H-362 1 I I I I I ; 1 COMMACK, NY 11725 ---------- I I -----------------1----- ------------------------------------------; -----------------------1---------------------------- - ------------------------------------------------------------------------------- 631-355-5556 1 1 1 PROVIDESTEP FOOTING AT 2'-0" MAX. -------------- ------------------------------------------------------- --------- ---------------------- ---------------------------------------1------------------------------------------------------------------------------- HORIZONTAL AND P-O" MAX. VERTICAL ALIGN L.r=1T ELE\/AT10N A201 1/4" = r-0" (WEST ELEVATION) Ll I j; DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 P. 631.271.5400 WWW.DDANY.NET Copyright 02025 All Rights Reserved. SEAL: PROJECT NORTH: hEXIST. SECOND FLOOR PLATE HEIGHT EL: 17'-I I I/2" CONT. LOW PROFILE RIDGE VENT. RIDGE l i VENT SHALL BE SHINGLE VENT 11 AS ® t MANUFACTURED BY 'AIR VENT' 3611 WIDE WEATHER WATCH VALLEY E E E FLASHING IN ALL VALLEYS (TYP) 0 EO PROJECT TITLE: RENOVATIONS & ALTERATIONS TO THE: hEXIST. SECOND FLOOR HEIGHT - a'-I I. 1/8" . — . 12 . — M c N E I LL RESIDENCE 710 OLD MENHADEN ROAD I-0' CUTCHOGUE NEW YORK 11935 WEAVE NEW SIDING IN w/ EXIST. (TYPJ ALIG , DRAWING TITLE: E E E E E E EXTERIOR ELEYATION5 PARGE EXPOSED FDN. AS REQ'D. TO MATCH EXIST. (TYPJ EXIST. FIRST FLOOR HEIGHT EL: O'-O" — — XIST_AVG. GRADE EL:. (- I'-a. " I I I I ------------' 1 DRAWN BY: 5DE SHEET N0. NEW EXIST. O1 1 1 1 I I I i I I CHECKED BY: 5,J5 ------------------------------------------- 11! 1 t 1 1 1 1 1 I 1 I DATE: �0.20.25 A=201 L--------------------- -------------------L------------------- t 1 i 1 LINE OF FOUNDATION/ FOOTING SHOWN ALIGN 1 DOTTED (TYP) SCALE: A5 NOTED 1 1 I 2 R16HT ELEVATION PROJECT N0. 2515 r-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------r-------------- A201 1/4" = 1'-o" (EA5T ELEVATION) L-------------------------------------------------------------------------------J------------------------------------------------------------------------1---------------------------------------------------------1------_----------J i l I 7771 3/4"x a Y4" L.V.L. R.B. ROOF CONSTRUCTION THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY - 5/g" GDX PLYWOOD SHEATHING THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE,AND ARE AND SHALL 2x8 R.R. ® I6" O.G. REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE - 19 ��WIDE FELT PARALLEL TO EAVES INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER - 36 WIDE STARTER STRIP OF WEATHER WATCH LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE 2x4 G.T. ® 32" O.G. (TYPJ (MIN. REFER TO ROOFING NOTE #1 ON A-100) ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL 2x4 CAMEL BACK ® MID-SPAN MAX. - (1) 30 LB. FELT UNDERLAYMENT COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. 81-0" O.G. (TYPJ - LIFETIME ARGHITEGTURAL ASPHALT 5HIN6LE5 TO IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION MATCH EXISTING OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING 2x8 G.J. ® I6" O.G. w/ R-30G BAIT INSULATION IN WINDOW HDR. SEE FRAMING PLAN (TYPJARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION'ALTERED BY' BAYS. FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE WALL CONSTRUCTION SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION SIMPSON' HOLD DN. (TYPJ -I/2" GYP. BD. LAW ARTICLE 147-ARCHITECTURE,SECTION 7307) -2"xb" WALL STUDS ® 16" O.G. w/ R-21 BATT IN5UL. 2x SUB-FASCIA WRAPPED w/ WHITE ALUM. (TYP) Y2" GDX WALL SHEATHING ISSUANCE: - _-- -'HYDRO6AP' HOU5E WRAP AS MANUF. BY N0. DATE: DESCRIPTION: 2x10 F.J. ® 16" O.G. w/ SOLID BRID61N6 ® MID-SPAN 12 BENJAMIN OBDYKE 8'-0" MAX. ATTACH TO UPSET HDR. w/ 'SIMP50N' _-- - -VINYL 51DIN6 TO MATCH EXISTING 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING (HU210) (TYP) (2) 1 3/4"x4 Y4" L.V.L. w/ I" x a" 5TL. PLT. FLUSH HDR. ATTIC UNDER WALL ABOVE — — - — - — — EXIST. SECOND FLOOR PLATE HEIGHT EL: 17'-II I/2;` 2 Ir_brr WALL CONSTRUCTION �V ' A-300 -2'x4G WALL STUDS ® 16" O.G. w/ R-15 BATT IN50L. 2x8 R.R. ® 16" O.G. ATTACHED TO 2x10 LEDGER BD. EEL] '-6"+ 2x6 G.J. ® I6" O.G. w/ R-30G GATT INSULATION IN G O5. NEW � -5/8" GYP. BD. ON GARAGE SIDE OF WALL BEDROOM #4 >- BAYS. 3/4" T8 6 PLY NO. w/ ir 2x8 R.R. ® I6" O.G. SIMPSON' HOLD DN. (TYP) 6LUE/NAIL (TYPJ • REMOVE EXIST. 51DIN6 4 SHEATHING;GAT 4� GUT BACK EXIST. R.R. AS REQ'D. FOR NEW LAY-ON ROOF MID-SPAN PROVIDE)Y GYP. BD. ---- - --- --- - a' II y8",� — EXIST. SECOND FLOOR HEIGHT EL: - 2x10 F.J. @16" O.G. w/ SOLID = -- - - - ®+ 5 EXIST. HDR. TO REMAIN Y.I.F. 4 NOTIFY ARCHITECT OF ANY DI5GREPANGIES BRIDGING ® MID-SPAN 8'-0" MAX. d PACK UP AS REG'D. FOR NEW R.R. TO AL16N w/ EXIST. ADJAGENT R.R. R-30G BATT INSUL. IN BAYS PROVIDE 5/8" GYP. BD. ON WALL5 AND GEILIN6 OF GARAGE (TYPJ SOLID BLOCK BELOW WALL I'-6° GRIPPLE WALL TO BE 2"x4" WOOD STUDS ® 16"o.c. w/ (1) 2x4 AGO. SILL PLATE d (1) D. FIR 2x4 SILL PLATE SECURED TO EXIST. SLAB w/ P.A.F. 2x10 F.J. ®16" O.G. w/ SOLID BRIDGING ® MID-SPAN 8'-0" MAX. d NEW NEW DEN f `� PROVIDE COPPER TERMITE SHIELD R-30C BATT IN5UL. IN BAYS LAUNDRY 7 \` NEW GARAGE PROVIDE 4" P.G. SLAB w/ 6 MIL V.B. w/ bxb1O,(o WWM OVER 6" COMPACTED POROUS FILL COMPACTED TO a5% DENSITY w/Y2" EXPANSION JOINT ® PERIMETER PROVIDE (R-10) R161D IN5UL. ON 3/4" T6 PLY NO. w/ �, WHERE SLAB MEETS FND. WALLS SEE GONG. FND. NOTES FOR ADDITIONAL INSIDE OF FND. WALL 6LUE/NAIL (TYPJ , REOUIREMENT5; PITCH SLAB TO GARAGE DOORYa' PER FOOT. SLAB TO MATCH AND AL16N w/ EXIST. GARAGE SLAB; DOWEL INTO EXIST. SLAB - — - — — EXIST. FIRST FLOOR HEIGHT EL: - NEW — — — - -EXIST. AV6. GRADE EL: -------------------------- r------------------ --------- -- ---�-- 0 2! GRAW - I EXIST. 6ARA6E SLAB 1 1 `----------- r SPACE m `�' z 8" WIDE POURED CONCRETE FOUNDATION WALL w/ (1) #4 VERTICAL BAR ® 72" O.G. EXTENDED INTO FOOTING, (1) WITHIN b" OF CORNERS AND y I p OPENINGS, (1) #4 HORIZONTAL REBAR AT TOP w/ 3" COVER w/ 12"x24" CONTINUOUS FOOTING TO BE 3'-0" BELOW GRADE w/ (2) #5 REBAR5 EXIST. FDN. TO BE REMOVED/ m CONTINUOUS 5/8" 6ALV. ANCHOR BOLTS ® 25" O.G. SEAM SEAL, COPPER CHOPPED TO BE BELOW NEW SLAB FLASHING BETWEEN FOUNDATION 4 (1) 2x4 AGO. SILL PLATE 4 (1) D. FIR STRUCTURAL KUROS SORBI-AVA ENGINEERING ' 2x4 SILL PLATE ENGINEER: 169 COMMACK ROAD I ISUITE I H-3 2 I ; COMMACK NY 11725 -------------------1--------------------------------------- ------------t i---------------------�1------------------------------------L------------------------------------------------------------------------ ---- 631-355-5556 8" WIDE POURED CONCRETE FOUNDATION WALL w/ #4 CONTINUOUS HORIZONTAL BAR WITHIN 6" OF TOP OF WALL w/ 50" OVERLAPPING ® SPLICE POINTSB #4 VERTICAL BARS ® 46" O.G. w/ 6" EMBEDMENT INTO FOOTING. w/12"x24" CONTINUOUS FOOTING TO BE 3'-0" BELOW ,, GRADE MINIMUM w/ (2) #5 REBAR5 CONTINUOUS; 5/8" 6ALV. ANCHOR BOLTS ® 48" O.G. SEAM SEAL, COPPER FLA5141146 BETWEEN x,. FOUNDATION $ (1) 2x6 AGO. SILL PLATE 4 (1) D. FIR 2x6 SILL PLATE; TUFF 4 DRY WATER PROOFING ON NEW FND. WALL; TOP OF WALL TO ALIGN w/ EXIST. ADJACENT PROVIDE 2" THIGK POURED CONGRETE VERMIN SLAB OVER 6 MIL POLYETHYLENE VAPOR RETARDER, JOINTS LAPPED b" MIN., OVER 4" Lj LA COMPACTED COURSE GRAVEL; MAINTAIN MIN. 3'-0" UNDER FLOOR SPACE DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 GROSS SECTI ON P. 631.271.5400 WWW.DDANY.NET I Copyright 02025 All Rights Reserved. SEAL: ;r. PROJECT NORTH: 00 1/4" = I'-O" 4 Pr, ` P y f l 2x8 R.R. G.J. (SEE FRAMING PLAN FOR SIZE) PROJECTITLE: 'SIMPSON' H3 HURRICANE TIE RENOVATIONS & ALTERATIONS TO THE: 2x(b TOP PLATE :----- -------------- M cNE ILL RESIDENCE r ;err 20 0 r 0 710 OLD MENHADEN ROAD CUTCHOGUE , NEW YORK 11935 DRAWING TITLE: GROSS SECTION + MODIFIED BIRDS MOUTH DETAIL DRAWN BY: SDE SHEET NO. 2 1�O� i l i� 51RI:)5 MOUTH DETAIL CHECKED BY: A500 I" = I'-O" (TYPICAL FOR 2x6 FRAMED WALLS) DATE: 1 0.20.25 Ae 1mk 300 SCALE: A5 NOTED PROJECT N0. 2515 777 ,7 I OPTION FOR: JACK STUDS ® WINDOWS 4 777 DOORS AND/OR ® ENDS SOLID 2x FULL BLOCKING HEIGHT O.G. or OF SE6MENTED 5HEARWALL THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY FULL H ENDWALL AS SPECIFIED ON PLANS THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE,AND ARE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER HOEDOWN ANCHOR ® ALL CORNER STUD CONNECTED TO 1 LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE TRANSFER SHEAR HOEDOWN ANCHOR ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL CORNER POSTS 51MP50N HTT22 i i i COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. 5IMP50N HTT22 ' IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION • � � � ' OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING . 6" O.G. $ 10" O.G. IF , BLOCKED CORNER POST -- - ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION"ALTERED BY" 2-I6d COMMON NAILS ® _--'"" �" FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE ° - - SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION ° LAW ARTICLE 147-ARCHITECTURE,SECTION 7307) THREADED ROD THREADED ROD ISSUANCE: STRUCTURAL RIDGE RIDGE BLOCKING ® ENDWALLS NO. DATE: DESCRIPTION: =_ '' 51MP50N STRONG TIE SIMP50N STRONG TIE 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING CATHEDRAL CEILIN65 1 LRU28 - 2"X8" X 10" OR 2"XI2" WITH COLLAR TIES AT 32" O.G. ; STUD TO TOP PLATE PROVIDE (FACE) (10) IOD X V2" NAILS 65-20 X 18" MIN. ® 16" O.G. WITTY (7) IOD ' PROVIDE (JO15T)(10) 50 X 1 Y2" NAILS COMMON NAIL PER RAFTER INSTALLED 51MPSON STRONG TIE H8 ® I6 O.G. OVER PLYWOOD W/ (5) IOD X I Y2' EACH END G5-20 X 18" MIN. WITH (7) IOD COMMON NAIL PER RAFTER INSTALLED OVER PLYWOOD • • SECOND FLOOR . • ATTACHMENT POINT ------------ JACK STUDS ® WINDOWS 4 DOORS AND/OR ® ENDS OPTION FOR: OF 5E6MENTED SHEARWALL BLOGKIN6 ® 24" O.G. or AS SPECIFIED ON PLANS SOLID 2x FULL HEIGHT ENDWALL HOEDOWN ANCHOR 5IMP50N HTT5 1 ^ MTSI6 CORNER STUD CONNECTED TO ' HOEDOWN ANCHOR ® ALL TRANSFER SHEAR CORNER POSTS i ' 11 51MP50N HTT5 EFTA 2-16d COMMON NAILS ® - - 6" O.G. 8 10" O.G. IF BLOCKED CORNER POST ° = ADJUSTABLE HANGER ADJUSTABLE HANGER ALL THREADED ROD ° ALL THREADED ROD • " 51MP50N 5TRON6 TIE SIMPSON STRONG TIE " 1-5-10 PROVIDE (10) IOD I Y2" NAILS L55U28 - 2 XS , 2 XIO AND 2 XI2 51MP50N GNW COUPLER - PROVIDE (FACE) (10) IOD X U'2' NAILS ;; 51MP50N GNW COUPLER - PROVIDE (JOI5T)(10) IOD X I Y2" NAILS BLOGKIN6 ® ENDWALLS 51MP50N 55TB " CLEAR 'SPAN ANCHOR BOLT 51MP50N 55TB " ANCHOR BOLT t v i STUD TO STUD CONNECTIONS ,,� �. : . ' .:` � e FIRST FLOOR 51MP50N 5TRON6 TIE LFTA ® 16' O.G. MIN. ae ATTACHMENT POINT (PROVIDE (8) IOD I Y2' NAILS EACH END OR (2) h1T512 STRUCTURAL KUROS SORBI-AVA ENGINEERING a ENGINEER: 169 COMMACK ROAD MT5I6 ® 16" O.G. MIN. (PROVIDE (7) IOD X 1 Y2" NAILS "` SUITE H-362 AT EACH END OR "05" COIL STRAP FLOOR TO CO NY 11725 FLOOR BAND WFGM TABLE 3.38 631-35 INSTALLED AT 16" 31-355-5556 O.G. (4) IOD I Y2" NAILS EACH END OD STRAP. 7 **Too' F I C A L 5 H E A R JIoN A L L A N 1:) 11-011 r4 ri `� 7*Arf= I GAL fo'LOOR4O � �O = 0F, E N I NO H0 �. 0w N A I L5 RAMINO 1:)E7AIL HURRICANE CLIP HIP CORNER PLATE ` 51MP50N STRONG TIE H8 ® 16" O.G. SIMPSON 5TRON6 TIE (HOP) A�� \A -� L41 W/ (5) IOD X 1 Y2" EACH END HGP - 2X MEMBER SIZE 2 : INSTALLATION OVER PLYWOOD IS HGP - 4X MEMBER ACCEPTABLE AS PER MIN. NAIL PROVIDE (6) IOD X I Y2" TO RAFTER PENETRATION (G-2003 P6.11) PROVIDE (6) IOD X I Y2" TO PLATES D13 / D14 MAX. OR SIMPSON STRONG TIE (MT512) ya Q Q NO NOTCHES PERMITTED 0/5 MAX. PROVIDE (7) IOD X I Y2" TO RAFTER p PROVIDE (7) IOD X I Y2" TO PLATES Q DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. 3 I Z�6E / RAf=7ER 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 T**fo'f= I CAL P. 631.271.5400 WWW.DDANY.NET Copyright ©2025 All Rights Reserved. 40 57RAFF I NO 1;)r TA I L S 1 I'-O" = FOR MEMBERS LESS THAN 4 IN. SEAL: f: r PROJECT NORTH: GNTILEVERED PORTION R.R. NOMINAL DIMENSION FLOOR JOIST— CENTER GUTS ~ ' DEPTH OF TAPER ' CUT 0/4 MAX. MEASURE AT 1 i L INSIDE FACE OF e SUPPORT J015f DEPTH TAPER CUT NO NOTCHES PERMITTED PROJECT TITLE: � Ca LBPS p RENOVATIONS & ALTERATIONS TO THE: McNEILL RESIDENCE D14 MAX. „VI GE I L I NS JO 1ST TAPER GUT 710 OLD MENHADEN ROAD 1 z o.c. *= FOR MEMBERS LE55 THAN 4 IN. CUTCHOGUE , NEW YORK 11935 Y2" V LAG I6" 51MP50N NOMINAL DIMENSION DRAWING TITLE: sIMP50N u210 u26 16" O FLOOR JOIST— END GUTS 10 IOD I PROVIDE , a PROVIDE 10 IOD 5/a" "ANCHOR 13OLT STRAPP I NCB DETAILS PROVIDE 5/8" X 12" ANCHOR BOLTS. ALL I Y2" NAILS ® 23 O.G. GUTTING, NOTCHING, DRI LL I NS FOUNDATION WALLS SHALL HAVE ANCHOR BOLTS FOR COLUMN TO 61RDER SET APPROXIMATELY ONE FOOT FROM EACH —_ _= CONNECTION SEE ADJACENT D/3 MAX. FRAM I NS DETAILS CORNER AND 6 TO 12 FROM EACH END, SPACED — 23" ON CENTER. THERE SHALL BE ANCHOR BOLTS DETAIL ON EITHER 51DE Of: ANY OPENING AND AT LEAST TWO BOLTS IN ANY' ONE SILL. PORCH/DEG /HOUSE PORGY/� I RDER �, FLOOR MASONRY/ CONCRETE CONNECTIONS G0NNEG710N ]SETA I LCONNECT 1 <2N DETAIL 2" MIN. FROM TOP 4 DRAWN BY: 5DE SHEET NO. 51MP50N STRONG TIE 5/8" DIA. LBPS WITH 3"x3" BEARING BOT. OF JOIST PLATE ® 23" o.c. AND C5 016" O.G. (FILL ALL NAIL HOLES CHECKED BY: 5J5 w/ 80 X I Y2" NAIL5) TO RUN UNDER 51LL PLATE AND WRAP D (ACTUAL DEPTH) UP AND OVER SILL. PLATE GUTTI NG NOTCHI NO I DRILLING DATE: 10.20.25 Am4A 002 r—RAMIN6 1:)r:7A1L51I1 = 1I-OII = SCALE: A5 NOTED T**�rf= ICAL CU771N6 , N07CHIN6 , 12RILLINS ETAILSI" 1'-0" PROJECT NO. 2515 f=RAM I NO r;�E7`A I L lto� �O µ; I THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY / THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE,AND ARE AND SHALL P.S.F. VALUES TO BE USED IN SELECTING ALL EXTERIOR MATERIALS FOR ROOFS 8 SIDEWALLS '�I I ( Jam, I I / �( G I I Q I I I 1 REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE I �L I I. I I T I V l /� O �../V I\ > INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER 1/ \�/ -- �.y / / (RESIDENTIAL CODE OF NEW YORK STATE) LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE /� / l ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL / / \ BASIC WIND SPEED BASIC WIND SPEED ✓�� f� Z RppF EFFECTIVE RppF EFFECTIVE COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. / l I fO PIrGH zoNE WIND AREA PITCH zoNE WIND AREA NUMBER OF NUMBER OF // / (50. FT) 110 F120 ( �� 110 120 JOINT DESGRI PTI ON COMMON NAIL BOX NAILS NAIL SPAG I NG IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I ANYWAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING 1 10 10.0 -21.5 105 -25A 1 10 la.a -21.6 29.7 -25.a ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION"ALTERED BY' T� I FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE 1 20 10.0 -212 10.0 -25.2 1 20 1a.4 -20.7 25.0 -24.6 SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION LAW ARTICLE 14TARCHITECTURE,SECTION 7307) RAFTER TO TOP PLATE (TOE-NAILED) 3 - Sd 3 - lod PER RAFTER %_,L% 1 50 10.0 -205 10.0 -24.4 1 5o 15.6 -1a.2 222 -22.0 7 J� I(� ISSUANCE: CEILING JOIST TO TOP PLATE TOE-NAILED 3 - ad - „�- � ,J ^ i 100 10.0 -la.a 10.0 -23.'1 N-� I loo I8.1 -I8.1 215 -215 ( ) 3 iOd PER JOIST -4_, 0 t - ul N0. DATE: DESCRIPTION: \, � Q � 2 10 10.0 -36s los -435 `� 2 10 IcIA -255 23.-► -30.3 CEILING JOIST TO PARALLEL RAFTER (PAGE-NAILED) (HEEL JOINT) ,, �\/ / 1 ��/• 0: O O 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING 4 r � A �_% ' F- � RAFTER SLOPE: 3:12 22 - Ibd 22 - 40d l t � / (`I o 2 20 10.0 -52.6 10.0 -58.8 (� o \ O 2 20 1a.4 -24 3 23.0 -2a.0 4:12 17 - Ibd 1-7 - 40d - - r m b - 2 a 22 -2-72 5:12 14 - 16d 14 - 40d EACH LAP � ��� J, 2 50 10.0 2"fS 10.0 32.7 2 5o I8. 2 2 �� t 7:12 10 - Ibd IO - 4od -� 2 100 10.0 -25.6 10.0 -26.1 2 100 18.1 -21.8 215 -25A 9:12 AND GREATER 8 - 16d 8 - 40d I 3 Io 10.0 -55.0 los -b6.4 3 io 1a.a -255 23.7 -303 GEILIN6 JOIST LAPS OVER PARTITION (PAGE-NAILED) ® INTERIOR ZONE 3 20 10.0 -455 10.0 -542 3 20 ILIA -24.3 25.0 -2a.0 RAFTER SLOPE: 3:12 22 - ibd 22 - 40d 4 ® PERIMETER ZONE 4:12 17 - 16d 17 - 40d �TE 3 so 10.0 -55.1 10.0 -3a.5 3 50 18.b -22.a 222 -2'12 5:12 14 - Ibd 14 - 40d EACH LAP I. FOR GABLE ROOFS ioy6 TO 45 6 PITCHES 7:12 l o - 16d 10 - 40d 3 100 t0.0 -23b 10.0 -28.1 3 100 I8.1 -21.8 215 -25.a ci:12 AND GREATER a - Ibd 8 - 40d 2. SEE FASTENING SCHEDULE A FOR NAILING IN EA. ZONE 1 10 12.5 -Ia.a 14A -23.'1 4 10 21.8 -25.6 25A -26.1 COLLAR TIE TO RAFTER (FAGS-NAILED) 3. AN EDGE INDICATES THE EDGE OF EA. PANEL RAFTER SLOPE: 3:12 7 - 10d 7 - l2d A FIELD INDICATES THE FIELD OF EA. PANEL 1 20 11.4 -ILIA 15.6 -23.0 4 20 20b -22.6 24.'1 -26.a 4:12 6 - lod 6 - 12d 4 - IOd 4 - 12d PER TIE I 50 10.0 -18.6 Il.a -222 4 50 lay -21.3 232 -25.4 6:12 AND GREATER 4 - IOd 4 - 12d I 100 10.0 -I8.1 IOS -215 4 100 18.5 -20.4 22.0 -242 �,- BLOCKING TO RAFTER (TOE-NAILED) 2 - ad 2 - IOd EACH END k// 2 10 125 -42.1 14A -50.1 1 5 10 21.0 -2a.1 25.a -34.'1 _ O ,/ �� J , N o 2 20 11.4 -382 15.6 -45.4 5 20 20.8 -212 24.1 -52.4 RIM BOARD TO RAFTER (END-NAILED) 2 - 16d 5 - 16d EACH END �( 2 50 10.0 -55.0 I1A -SCIZ 5 50 lay -24b 23 2 -2a 3 2 2 Ioo 10.0 -2a.1 105 -34.7 5 100 185 -22.6 22.0 -26.a - TOP PLATE TO TOP PLATE (FACE-NAILED) 2 -16d I 2 - Ibd I PER FOOT Z , 3 10 125 -42.1 14.a -50.1 FOR 51: I FOOT = 304.6mm, 150. FT. - O.Oa2a 50. METERS, • \� y If / Z / /=( "rJ I / I MPH - I bOa KM/H - \� 0 / O f� J TOP PLATES AT INTERSECTIONS (FACE-NAILED) 4 - 16d 5 Ibd JOINTS -EACH SIDE g � 2 \-y� I �� l t i���! � 3 20 11.4 -382 13.6 -45.4 NOTES: FOR EFFECTIVE WIND AREAS BETWEEN THOSE GIVEN ;\O ABOVE THE LOAD MAY BE INTERPOLATED;OTHERWISE USE , / 3 50 10.0 -55.0 Il.a -3a.3 THE LOAD ASSOCIATED WITH THE LOWER EFFECTIVE AREA. STUD TO STUD (FAGS-NAILED) 2 -16d 2 - Ibd 24" O.G. __� j� TABLE VALUES SHALL BE ADJUSTED FOR HEIGHT AND EXPOSURE / / -� _ BY NNLTIPLYING BY THE ADJUSTMENT COEFFICIENT IN TABLE/ / , f � �, 3 100 10.0 -2a.1 IOS -34.'I �� RSO12(3). SEE FIGURE R3OI20) FOR LOCATION OF ZONES. HEADER TO HEADER (FACE-NAILED) 16d 16d I6 OG ALONG ED&E5 PLUS AND MINUS SIGNS SIGNIFY PRESSURE ACTING TOWARD AND AWAY FROM THE BUILDING SURFACES. TOP OR BOTTOM PLATE TO STUD (END-NAILED) 2 - Ibd 2 - 4od PER STUD ,0 O' BOTTOM PLATE TO FLOOR JOIST, BANDJO 15T, ENDJO 1ST OR BLOCK I N 2 - 16d 1,2 2 - Ibd I,2 PER FOOT ® INTERIOR ZONE FRE (PAGE-NAILED) STRUCTURAL KUROSSORBI-AVAENGINEERING PERIMETER ZONE I ✓✓VRE ZONES ENGINEER: 169 COMMACK ROAD g�NOTE: `K k 4O1 O O R � R �c l-II I N SUITE H-362 I. FOR HIPPED ROOFS 10� TO 4516 PITCHES COMMACK, NY 11725 JOIST TO SILL, TOP PLATE OR GIRDER (TOE-NAILED) 4 -8d 4 - 10d PER JOIST 631-355-5556 2. SEE FASTENING SCHEDULE A FOR NAILING IN EA. ZONE BRIDGING TO JOIST (TOE-NAILED) 2 - ad 2 - 10d EACH END 3. AN EDGE INDICATES THE EDGE OF EA. PANEL A FIELD INDICATES THE FIELD OF EA. PANEL BLOGKING TO JOIST (TOE-NAILED) 2 - ad 2 - lod EACH END 1�1A L_ 11�1� 1�lOT�s WINDBORNE DEBRIS PROTECTION FASTENING BLOCKING TO SILL OR TOP PLATE (TOE-NAILED) 3 - Ibd 4 - 16ci EACH BLOCK i SCHEDULE FOR WOOD STRUCTURAL PANELS I I. NAILING REQUIREMENTS ARE BASED ON WALL SHEATHING NAILED 6 ON CENTER AT THE PANEL EDGE. IF LEDGER STRIP TO BEAM (FAGE-NAILED) 3 - 16d 4 - 16d EACH JOIST [REFER TO TABLE R3012.12 OF THE RESIDENTIAL CODE OF NEW PORK STATE] WALL SHEATHING 15 NAILED 5" ON CENTER AT THE PANEL EDGE TO OBTAIN HIGHER SHEAR GAPAG I TI ES, NAILING REQUIREMENTS FOR STRUCTURAL MEMBERS SHALL BE DOUBLED, OR ALTERNATE CONNECTORS, FASTENER SPADING INCHES JOIST ON LEDGER TO BEAM (TOE-NAILED) 3 - ad 3 - IOd PER JOIST FASTENER TYPE PANEL SPAN 4 FEET < 6 FEET < •. SUCH AS SHEAR PLATES, SHALL BE USED < 4 FEET PANEL SPAN PANEL SPAN _ BAND JOIST TO JOIST (END-NAILED) 3 - Ibd 4 16d PER JOIST TO MAINTAIN THE LOAD PATH. <6 FEET < s FEET NO. 8 WOOD SCREW BASED ANCHOR w/ 2" 16 10 8 EMBEDMENT LENGTH BAND JOIST TO SILL OR TOP PLATE (TOE-NAILED) 2 - l6d 2 - 16d PER FOOT w- 2. WHEN WALL SHEATHING IS CONTINUOUS OVER CONNECTED MEMBERS, THE TABULATED NUMBER OF NAILS NO. 10 WOOD SCREW BASED ANCHOR w/2" SHALL BE PERMITTED TO BE REDUGED TO I - 16d PER FOOT. EMBEDMENT LENGTH 16 12 a R O O F= � �-t E= A T 1-4 I i�l C� 3. CORROSION RES 15TANT 11 GAGE ROOFING NAILS AND 16 GAGE STAPLES ARE PERMITTED; GHEGK I BG FOR 440 LA 5 �� G� ANCHOR `12. 16 16 16 ADDITIONAL REQUIREMENTS. STRUCTURAL PANELS: PANEL INTERMEDIATEDIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. EDGES SUPPORTS 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 4. ALL GUANTI TI ES ARE BASED ON 16" OG SPAG I NG FOR RAFTERS, JOISTS AND STUDS. MINIMUM UNIFORMLY DISTRIBUTED DESIGN LOADS INTERIOR ZONE ad IOd 411 6" P. 631.271.5400 WWW.DDANY.NET [REFER TO TABLE R301S OF THE RESIDENTIAL CODE OF NEW PORK STATE] Copyright ©2025 Ali Rights Reserved. 5. FOR ROOF SHEATHING WITHIN 4 FEET OF THE PERIMETER EDGE OF THE ROOF, INGLUDING 4 FEET ON EACH PERIMETER EDGE ZONE ad lod 411 4,:: SEAL: PROJECT NORTH: SIDE OF THE ROOF PEAK, THE 4 FOOT PERIMETER EDGE ZONE ATTACHMENT REQUIREMENTS SHALL BE USE =FLI\/E LOAD DEAD LOAD F USED. GABLE ENDWALL RAKE WITH LOOKOUT BLOCK ad IOd .� q EXTERIOR BALCONIE54DEGKS 40 psf 10 psf tr 6. FOR WALL SHEATHING WITHIN 4 FEET OF THE GORNERS, THE 4 FOOT EDGE ZONES ATTACHMENT ATTICS WITHOUT STORAGE ('ROOF BELOW 3 PITCH) 10 psf 10 psf G E= I L I 1�1 G S }-� E_ T 1-•I' 1 1�l G '' REQUIREMENTS SHALL BE USED. ATTICS WITH STORAGE (ROOF ABOVE 3 PITCH) 20 psf 10 psf GYPSUM WALLBOARD 5d COOLERS 5d COOLERS 7" EDGE / 10" FIELD 4 ROOMS OTHER THAN SLEEPING ROOMS 40 psf 10 psf SLEEPING ROOMS 30 psf 10 psf �-- L- � H E T H 1 STAIRS 40 psf 10 psf STRUCTURAL PANELS/HARDBOARD PANEL INTERMEDIA PROJECT TITLE: NOTE: EDGES SUPPORTS ALL STRAPPING TO BE V4"x20 GAUGE STEEL OR 'SIMPSON' EQUIVALENT GUARDRAILS AND HANDRAILS 200 psf 10 psf RENOVATIONS & ALTERATIONS TO THE: - 0520 (COILED STRAP) INTERIOR ZONE6 ad lod 6" 6" (ALL STRAPPING SHALL BE INSTALLED PRIOR TO SHEATH I NGZ 4' EDGE ZONE 6 ad lod 6 (oil M c N E I LL RESIDENCE MINIMUM ROOF L11�E LOADS NOTATION: [REFER TO TABLE R3015 OF THE RESIDENTIAL CODE OF NEW YORK STATE] A- NUMBER OF 8d NAILS ® EA. END OF STRAPPING (TABLE 3."1, P. 157) FIBERBOARD PANELS: A D B- NUMBER OF SILL STUDS-ON FLAT(DOES NOT APPLY TO DOORS) (TABLE 3.238, P. la3) TRIBUTARY LOADED 7/16" (rid - 3" EDGE / 6" FIELD 710 OLD MENHADEN ROAD C- NUMBER OF FULL HEIGHT KING STUDS ROOF SLOPE AREA IN S.F. FOR ANY 25/32" ad - 3" EDGE / 6" FIELD 0 EA. SIDE OF HEADER (TABLE 5.250, P. Ia8) CUTCHOGUE , NEW YORK 11935 D- NUMBER OF Ibd NAILS, END-NAILED THROUGH ADJACENT KING STUD STRUCTURAL MEMBER C TO END OF HEADER ® EA. SIDE (TABLE 3.'1, P. 15-) GYPSUM WALLBOARD 5d COOLERS 5d COOLERSE- NUMBER OF JACK STUDS 7" EDGE / 10" FIELD DRAWING TITLE: F- NUMBER OF Ibd NAILS, END®-NAILED THROUGH ADJA EA. END OF HEADER CENT JACK STUD I) O TO 200 OI TO 60 OVER 600 NAB I L I NG SCHEDULE TO END OF SILLS) ® EA. SIDE (DOES NOT APPLY TO DOORS) (TABLE 5.8, P. 15'1) FLAT OR RISE LESS THAN 4 INCHES 20 16 12 PARTICLE BOARD PANELS 8d ad SEE MANUFACTURER B � PER FOOT(1:3) FASTENING SCHEDULE B RISE 4 INCHES PER FOOT(1:3) TO LESS 16 14 12 L O O R A T 1 G ROUGH OPENING FRAMING REQUIREMENTS FOR WINDOW/DOOR OPENINGS THAN 12 INCHES PER FOOT(I:I) RISE 12 INCHES PER FOOT(1:1) AND [IN ACCORDANCE WITH GREATER 12 12 12 GONSTRI1GT10N MANUAL 2015 WITIoNI STRUCTURAL PANELS: F I" OR LESS ad IOd 6" EDGE / 12" FIELD NOTATION ALLOWABLE DEFLECTION OF STRUCTURAL MEMBERS GREATER THAN I" loci ibd 6" EDGE / 6" FIELD ROUGH A B G D E F OPNG [REFER TO TABLE R301.'1 OF THE RESIDENTIAL CODE OF NEW YORK STATE] DRAWN BY: SDE SHEET NO. 2'-0" 2 (1) 2x4 I I I I STRUCTURAL MEMBER ALLOWABLE DEFLECTION CHECKED BY: 5JS 4'-0" 4 (1) 2x4 2 2 2 2 RAFTERS HAVING SLOPES GREATER THAN s(2 WITH NO GEILIN6 ATTACHED TO GEILIN6 LA 50 DATE: 10.20.25 ®1 (2) 2x4 OR (I) 2x6 3 3 3 3 INTERIOR WALLS AND PARTITIONS H/I80 Aa4 8'-0" 8 1 (2) 2x4 OR (I) 2x6 3 3 3 3 FLOORS AND PLASTER CEILINGS L/360 SCALE: AS NOTED 10'-O" 10 (2) 2xb 4 4 4 4 ALL OTHER STRUCTURAL MEMBERS L/240 PROJECT N0. 2515 12'-0" 12 (2) 2xb 5 5 5 5 EXTERIOR WALL-WIND LOADS WITH FLEXIBLE FINISHES L/120 777-1 I E S THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE,AND ARE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. ELEGTR I GAL LEGEND IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING "Z" "Z" = FIXTURE DESIGNATION - SEE FIXTURE TYPE BELOW ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION"ALTERED BY a a = CIRCUIT DESIGNATION FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION DUPLEX RECEPTACLE - WP INDICATES WATER PROOF LAW ARTICLE 147-ARCHITECTURE,SECTION 7307) GFI DUPLEX RECEPTACLE WATER RE-515TANCE GFI ISSUANCE: QUAD RECEPTACLE NO. DATE: DESCRIPTION: PTV (GABLE) CONNECTION 1. 110-7075 ISSUED FOR BUILDING DEPARTMENT FILING SINGLE POLE SWITCH "DEGORA TYPE" SINGLE POLE DIMMER 5WITGH "DECORA TYPE" $ $3 3-WAY 5WITGH "DECORA TYPE" $a 4-WAY 5WITGH "DEC ORA TYPE" $,i JAMB 5WITGH $1L SINGLE POLE 5WITGH W/ INDICATOR LIGHT ,DECoRA,, EX EXISTING LIGHT FIXTURE/ 5WITGH TO REMAIN PROVIDE JUNCTION BOX FOR OWNER PROVIDED A GEILING FAN (10IF INDICATED MEANS W/ LIGHT B - - 5" CEILING RECESSED C � 4"GEILING RECESSED \ D 40 4"GEILING RECESSED w/EYEBALL -- \\ GFI ® 42" i i �\ DN. a E p OWNER PROVIDED WALL MOUNTED 50ONGE A.F.F. C SD G F O OWNER PROVIDED VANITY WALL MOUNTED LIGHT GFI G / i I r1 K i \ nAR-EA / NEW \ G JO JUNCTION BOX FOR OWNER PROVIDED HANGING FIXTURE qHOME OFFICEEXIST. H 4- 4" RECESSED w/ SHOWER LEN5E GFI ® 42" I i / i / / PORCHA.F.F. / K�j / / I OWNER PROVIDED EXTERIOR WALL MOUNTED LIGHT T I OWNER PROVIDED GHANDELIER O \I G I G� G _ J O (mp) INDICATES MOTOR POWERED LOWERING DEVICE i i ¢) ' G� G I WIRED TO SEPARATE 5WITGH � i K GFI ® 42" Q / ; �; I K 0 OWNER SELECTED HANGING PENDANT LIGHT A.F.F. O I � � � I L E----� UNDER CABINET LED LIGHT i I �' I RENOVATED \ -- - -- \ 4 Ft. LED STRIP LIGHT W/ COVER ------------ _-�\ \ KITCHEN I ENO M DINING ROOM �-- - - - N GEILING MOUNTED PORCELAIN FIXTURE STRUCTURAL KUROS SORBI-AVA ENGINEERING \NEW LAUNDRY\J�j � � - - -- ---CFI ® 42" \ M- ENGINEER: 169 COMMACK ROAD ------ -------- A.F.F..F. W - ' 0 CABINET LIGHT SUITE H-362 I `` w L------ - �-- CK, NY 11725 i i \ \ O P ------ UNDER GABINET LED TAPE LIGHTING 631-355-5556 OWNER'S G 7. i CLOSET Q OWNER PROVIDED ARTWORK LIGHTING \ �l SD G J G C� I R O OWNER PROVIDED SURFACE MOUNTED LIGHT 77 l\ I Sp ® RELOCATED / N0 LIGHT FIXTURE / 5 o OWNER PROVIDED LED LIGHT BAR WITH COVER / NEW DEN \ BATH #I £ / EX TOILET EXHAUST FAN CONNECTED TO LIGHT 5WITGH ;,. / \ ---- � (It) IF INDICATED MEANS WITH LIGHT (t) MEANS TIMER ® 42" l EXIST. A.F.F. NOTE: _ �= PROVIDE DIMMERS ON ALL 5WITGHE5 WHENEVER POSSIBLE Fol DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. --- — 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 EXIST• P. 631.271.5400 WWW.DDANY.NET dbEXISTING I I LIVING ROOM Copyright 02025 All Rights Resemd. --- --- FOYER I I SEAL: PROJECT NORTH: UTILITY NOTES: I. THE HVAG CONTRACTOR SHALL VERIFY THE 51ZE AND - - -- / - --j I ( PERFORMANCE OF THE EXISTING 5Y5M(5) AND CALCULATE / 1.1 THE NEW REQUIREMENTS TO DETERMINE IF THE EXISTING . I DN' SY5M(5) WILL BE ADEQUATE TO ACCOMMODATE THE NEW I \ / ADDITION. IF THE SY5TEM(5) ARE NOT ADEQUATE, THE G-ENERAL CONTRACTOR SHALL INGLUDE IN HIS BID THE C05T ' \ a OF EXPANDING THE 5Y5TEM(5) A5 REQUIRED FOR PROPER I PERFORMANCE. f I NEW \\ I � GARAGE I I 2. THE PLUMBING CONTRACTOR TO VERIFY THE 51ZE OF RELOCATED \ I EXIST. EXISTING DOME5TIG HOT WATER SYSTEM AND DETERMINE IF PROJECT TITLE: GARAGE DOOR / PORCH THE EXISTING 5Y5M WILL BE ADEQUATE FOR THE NEW AND RENOVATIONS & ALTERATIONS TO THE: OPENER / i / EXISTING LOADS COMBINED. IF SYSTEM 15 NOT ADEQUATE, COST OFO EXP RAL CONTRACTOR TGHTE SYSTEM AS REQUIRED FOR PRALL INCLUDE IN H15 BID OPER M c NE ILL RESIDENCE ' I ' PERFORMANCE. r- 3. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE 51ZE OF M / I m 0 a a ❑O THE EXISTING ELECTRIC SERVICE FOR ADEQUACY IN 710 OLD MENHADEN ROAD (�� ( PROVIDING NEW ELECTRICAL INSTALLATIONS AS 5140WN. L-J I i I UPGRADE SERVICE, METER, PANEL, ETC. AS REQUIRED. ALL CUTCHOGUE , NEW YORK 11935 I I i ELECTRICAL WORK TO BE FIRE UNDERWRITERS INSPECTED I DRAWING TITLE: AND APPROVED. SUBMIT CERTIFICATE TO OWNER UPON WN I I RECEIPT. THE GENERAL CONTRACTOR SHALL INCLUDE IN HI5 I ST FLOOR LIGHTING I i i ELF THE REQUIREMENTS.THE UP6RADE AND ALL RELATED ELECTRICAL PLAN / ELECTRICAL NOTE: PROVIDE ALL ELECTRICAL OUTLETS, SWITCHES, ETC. 1 \ / AGGORDING TO ALL STATE AND LOCAL CODES. -_ COORDINATE WITH OWNER, LOCATIONS OF ALL ADDITIONAL 5WITGHIN6, OUTLETS AND LIGHTING. I- PROVIDE ELECTRICAL CONVENIENCE RECEPTACLE OUTLETS PER E3a01. COORDINATE WITH OWNER DRAWN BY: 5DE SHEET NO. ADDITIONAL REQUIREMENTS. 2- PROVIDE CONVENIENCE RECEPTAGLE OUTLET IN CHECKED BY: 5,.15 GARAGE, PER E3CTOIA WITH GFCI, PER E3a02.2 DATE: 10.20.25 Ell 3- PROVIDE ONE WALL 5WITGH CONTROLLED LIGHTINGON f:: 1R!5T f:: L16HTINO I$ ELECTRICAL FLAN NOTE' NOTE: THE EXTERIOR 51DE OF EACH OUTDOOR EGRESS DOOR SCALE: A5 NOTED ELECTRICAL CONTRACTOR TO REVIEW LIGHTING AND 5WITGHING ELECTRICAL CONTRACTOR TO COORDINATE ANY ADDITIONAL HAVING GRADE LEVEL ACCESS IN ACCORDANCE WITH E100 1/4" = 1'-0" LAYOUT WITH CLIENT IN FIELD PRIOR TO INSTALLATION EXTERIOR LIGHTING REQUIREMENTS WITH OWNER E3903.3 PROJECT N0. 2515 4- GFCI's ARE TO BE PROVIDED, PER E3C102 7777 9 THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECTS SERVICE,AND ARE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT, ELECTRICAL LEGEND IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING - -- - "Z" "Z" = FIXTURE DESIGNATION - SEE FIXTURE TYPE BELOW ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION'ALTERED BY _ a a = CIRCUIT DE516NATION FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION �@ DUPLEX RECEPTACLE - WP INDICATES WATER PROOF LAW ARTICLE 147-ARCHITECTURE,SECTION 7307) =@GFI DUPLEX RECEPTACLE WATER RESISTANCE GFI ISSUANCE: QUAD RECEPTACLE F1.N0. DATE: DESCRIPTION: TV (GABLE) CONNECTION 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING I � $ SINGLE POLE SWITCH "DECORA TYPE" 51NGLE POLE DIMMER SWITCH "DECORA TYPE" $3 3-WAY SWITCH "DECORA TYPE-- 4-NAY 5WITGH "DECORA TYPE" $j JAMB 5WITGH 1� SINGLE POLE 5WITGH W/ INDICATOR LIGHT "DECORA" I --------- EX EXISTING LIGHT FIXTURE/ 5WITGH TO REMAIN PROVIDE JUNCTION BOX FOR OWNER PROVIDED I A CEILING FAN j (10IF INDICATED MEANS W/ LIGHT B 5" GEILING RECESSED I i G � 4"GEILIN6 RECESSED D 40 4"GEILING RECESSED w/EYEBALL Fq I a•• s E 0 OWNER PROVIDED WALL MOUNTED SCONCE NEW G---- ' 0 It) Oo • ' F OWNER PROVIDED VANITY WALL MOUNTED � TED L I6HT G JO JUNCTION BOX FOR OWNER PROVIDED HANGING FIXTURE RENO. BATH #5// i i H -�- 4" RECESSED w/ 5HOWER LEN5E _ _ I RENO. EXIST. _ _ _ / — — i 'FI BALCONY i OWNER PROVIDED EXTERIOR WALL MOUNTED LIGHT BEDROOM #3 T T I/o J OWNER PROVIDED CHANDELIER G (It) NEW G� I I (mp) INDICATES MOTOR POWERED LOWERING DEVICE � i RENO� i O WIRED TO SEPARATE 5WITGH \ K-IN\ K O OWNER SELECTED HANGING PENDANT LIGHT - - - - - - - - - - - - SD I GLOS. I F G� I G I L UNDER CABINET LED LIGHT — I- I M 4 Ft. LED STRIP LIGHT W/ COVER II EX RENO. N � GEILING MOUNTED PORCELAIN FIXTURE STRUCTURAL KUROS SORBI-AVA ENGINEERING BEDROOM #1 ENGINEER: 169 COMMACK ROAD 0 � CABINET LIGHT SUITE H-362 FI B EX COMMACK, NY 11725 631-355-5556 —' P -----. UNDER CABINET LED TAPE LIGHTING • Ea. Ea. I ` � J (It) Q J— OWNER PROVIDED ARTWORK LIGHTING SD EXIST. HALL - G RENO. ccc( `t BATH #4 \ i -- R OWNER PROVIDED SURFACE MOUNTED LIGHT G s x.; � NEW � I r �� � 7 � ��\ BATH #2 OWNER PROVIDED LED LIGHT BAR WITH COVERLj fi TOILET EXHAUST FAN CONNECTED TO LIGHT 5WITGH --- ; I \ (It) IF INDICATED MEANS WITH LIGHT (t) MEANS TIMER i NEW --- -- \ ) 1 /BEDROOM #4 ___ __ Lo NOTE: _-- -- PROVIDE DIMMERS ON ALL SWITCHES WHENEVER P0551BLE G .,. RENO. I BEDROOM #2 DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. -- --- ;�." I 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 P. 6 31.2 71.5 4 0 0 WWW.DDANY.NET Copyright ©2025 All Rights Reserved. - -1--- I I S „ PROJECT NORTH: UTILITY NOTES: '` I I. THE HVAG CONTRACTOR SHALL VERIFY THE SIZE AND PERFORMANCE OF THE EXISTING 5Y5TEM(5) AND CALCULATE RNO. I THE NEW REQUIREMENTS TO DETERMINE IF THE EXISTING G1�05. I SYSTEMS) WILL BE ADEQUATE TO ACCOMMODATE THE NEW f ADDITION. IF THE 5Y5TEM(5) ARE NOT ADEQUATE, THE �. a 11 GENERAL CONTRACTOR SHALL INCLUDE IN HI5 BID THE COST OF EXPANDING THE SY5TEM(5) AS REQUIRED FOR PROPER PERFORMANCE. t. 2.THE PLUMBING CONTRACTOR TO VERIFY THE 51ZE OF EXI5TING DOMESTIC HOT WATER SYSTEM AND DETERMINE IF PROJECT TITLE: THE EXISTING SYSTEM WILL BE ADEQUATE FOR THE NEW AND RENOVATIONS & ALTERATIONS TO THE: EXISTING LOADS COMBINED. IF SYSTEM IS NOT ADEQUATE, THE GENERAL CONTRACTOR SHALL INCLUDE IN HI5 BID THE G05T OF f:E ORMANGE.�ING THE SYSTEM AS REQUIRED FOR PROPER M c N E I LL RESIDENCE 3.THE II II SHALLCTR VERIFY TH THE EXIS NG EILECTRIC S CAL CONT RVI CE FORADEQ AGY IN E SIZE of �10 OLD PROVIDING NEW ELECTRICAL INSTALLATIONS AS SHOWN. MENHADEN ROAD I UPGRADE SERVICE, METER, PANEL, ETC. AS REQUIRED. ALL CUTCHOGUE , NEW YORK 11935 ELECTRICAL WORK TO BE FIRE UNDERWRITERS INSPECTED AND APPROVED. SUBMIT CERTIFICATE TO OWNER UPON DRAWING TITLE: IPT. THE ERAL CONTRACTOR SHALL INCLUDE BID En-EE COST FOUR THE UPGRADE AND ALL RELATED IN HIS 2ND FLOOR LIGHTING � II II ELEGTRICAL REQUIREMENTS. ELECTRICAL PLAN LL . . . . . . . — — — — — — —— . . . - - — — J J ELECTRICAL NOTE: PROVIDE ALL ELECTRICAL OUTLETS, 5WITGHE5, ETC. ACCORDING TO ALL STATE AND LOCAL CODES. COORDINATE WITH OWNER, LOCATIONS OF ALL ADDITIONAL SWITCHING, OUTLETS AND LIGHTING. I- PROVIDE ELECTRICAL CONVENIENCE REGEPTAGLE OUTLETS PER E3901. COORDINATE WITH OWNER DRAWN BY: SDE SHEET NO. ADDITIONAL REQUIREMENTS. 2- PROVIDE CONVENIENCE RECEPTACLE OUTLET IN CHECKED BY: GARAGE, PER E3a01A WITH GFGI, PER E31102.2 /`� NOTE: DATE: 10.20.25 I EB ECCN� f L O O L i G H T I N G I$ E L E G T I A L FLAN NOS 3- PROVIDE ONE WALL 5WITGH CONTROLLED LIGHTING ON Em101 THE EXTERIOR SIDE OF EACH OUTDOOR EGRESS DOOR SCALE: A5 NOTED ELECTRICAL CONTRACTOR TO REVIEW LIGHTING AND SWITCHING ELEGTRICAL CONTRACTOR TO COORDINATE ANY ADDITIONAL HAVING GRADE LEVEL ACCESS IN ACCORDANCE WITH • I O I i/4" = I'-O" LAYOUT WITH CLIENT IN FIELD PRIOR TO INSTALLATION EXTERIOR LIGHTING REQUIREMENTS WITH OWNER E3903.3 PROJECT N0. 25I5 4- GFGI's ARE TO BE PROVIDED, PER E3c102 ,. ,. . i --moo &ENERAL N07E5 T""IT"N THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS hNC I THE ARCHITECT SHALL ASSIST THE OWNER IN FILING AND OBTAINING ALL LOCAL BUILDING DEPARTMENT THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECTS SERVICE,AND ARCED B y REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEiNqlt INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED APPROVALS FOR THE GONSTRU�GTION DOCUMENTS OF THIS PROJECT. ALL FEES RELATED TO THIS �LID E ,l" ,�„ E ;�" ,., '"� LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT.APPROVAL PFZOGE-55 SHALL BE PAID FOR BY THE OWNER. UPON BUILDING DEPARTMENT APPROVAL, AND � '' `t PROCURING A BUILDING PERMIT„ THE GENERAL CONTRACTOR 15 NOW RE5PON51BLE FOR THE TAKING OUT �'`��"t.A� ��� ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAI AND PAYMENT FOR ANY ADDITIONAL PERMITS AND/OR RELATED FEES REQUIRED TO 5UGGE55FULLY ' '' '' COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPY � UPANCY" IS SECURED. R rA OK—�� IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRE, COMPLETE THI= PROJECT UNTIL 'THE "GERTIFIGATE OF OCC No ��_ J�� Of A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SE 2 CONTRACTOR SHALL PERFORM ALL WORK IN COMPLIANCE WITH ALL APPLICABLE CODES,CODE AMENDMENT5, 5TANDARD5, RULES AND REGULATIONS INGLUDIN6, BUT NOT LIMITED TO THE FOLLOWING: ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTEh M AD ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION'ALTERED B', FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE LOCAL ZONING ORDINANCE SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION THE NEW '(ORK STATE RESIIDENTIAL GODS - 2020 EDITION LOCAL BUILDING DEPARTMENT REQUIREMENTS WOOD FRAME CONSTRUCTION MANUAL FOR ONE AND TWO FAMILY DWELLINGS (2018 EDITION) 7100 EN N ROAD W ARTICLE 147-ARCHITECTURE,SECTION 7307) 3 THE CONTRACTOR 15 RE5PON51IBLE FOR "METHODS AND MEANS OF CONSTRUCTION". CUTCHOGU Y 11935 ISSUANCE: 4 CONTRACTOR SHALL PROVIDE, AND BE RESPONSIBLE FOR, ALL NEGE55ARY E � N 5HORIN(5 AND BRAGIN6 AS REGUIRED FOR THE SAFE INSTALLATION OF HI5 WORK. NO. DATE: DESCRIPTION: 5 SHOULD UNFORESEEN CONDITIONS OR OTHER CAU5E5 NECE-551TATE CONSTRUCTION DETAILS NOT IN 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING ACCORDANCE WITH THESE PLAINS, CONTRACTOR SHALL NOTIFY THE PROPER AUTHORITIES AND SUBMIT HIS N LVISED PER OWNER CHANGES DETAILS SHOI^IING THE PROPOSED METHOD TO AC-COMPL15H THE REQUIRED RESULT. EN:E-�R6­' ® 04.09.26 ADD BASEMENT EGRESS STAIR 6 WHEN OWNER/CONTRACTOR 516IN CONTRACT, THE AIA GENERAL CONDITIONS FORM A201 SHALL GOVERN. 0 ry <o 0� NO. 7 NO NOTE OR LACK THEREOF 5HIALL BE CONSTRUED A5 RELIEVING THE CONTRACTOR FROM THE EXECUTION ski o 3qo OF ALL WORk- IN ACCORDANCE WITH ALL STATE AND/OR LOCAL CODES. S 8 THE GONTRAC;TOR IS NOT TO ScGALE DRAWIN6(5) AND 15 TO USE DIMEN51ONAL NOTATIONS ONLY. FF o_ „ Cy $3 00 V. q THE GENERAL., CONTRACTOR AMD ALL SUBCONTRACTORS SHALL VISIT THE SITE AND VERIFY ALL DIMENSIONS C� /y� 0p /N � � AND JOB CONDITIONS PRIOR TO CONSTRUCTION AND SHALL REPORT TO THE ARCHITECT FOR RESOLUTION U y TOR TO COMMENCEMENT OF IWORK ANY DISCREPANCIES OR OMI5510N5 WHICH WOULD INTERFERE WITH THE TTM SATISFACTORY COMPLETION OF THE WORK. 10 THE GENERAL-. CONTRACTOR SMALL NOTIFY THE ARCHITECT OF ANY ERRORS OR AMBIC-UITIE`.5 IN AND -' �U N'C• A,O OOL FE. I'-3" . BETWEEN THE PLANS, DRAWINGS AND SPECIFICATIONS PRIOR TO PROGEEDING WITH THAT PORTION OF THE WORK. IF SUCH NOTICE 15 NOT FURNISHED To THEDEEMED ARCHITECT, THE CONTRACTOR SHALL BE DMED TO HAVE QUIP. \'a INSPECTED THE PLANS, DRAWIINGS, 5PEGIFIGATION5 AND HAS FOUND THEM IN PROPER FORM FOR EXECUTION. Compliance c e I c a @ ry 12 0 3:� � -� EXIST. VINYL SHED II GONTRAGTOR TO PROVIDE ALL NECESSARY BARRICADES, GUARDS, WARNING LIGHTS, SIGNS, ETC,., TO INSURE REOV. R " THE SAFETY OF THE WORK AREA. Project Information YARD SETBACK 5' 14 0' 12 CONTRACTOr,, SHALL PROVIDE ALL MATERIALS, PERFORM ALL WORK AND INSTALL ALL MATERIALS IN v ACCORDANCE WITH RECOGNIZED GOOD STANDARD PRACTICE. CONTRACTOR IS RESPONSIBLE FOR Project Title: McNeill Residence LLt INFORMATION THAT PERTAINS SOLELY TO THE FABRICATIONS PROCESS OR THE TECHNIQUES OF Energy Code: 2018 IECC 4W v-4 O ,;°` Z CONSTRUCTION AND FOR COORDINATION OF THE WORK OF ALL TRADES. Location: Cutchogue,New York 2 Lv LOT No. 347 0 --co,oItJ Q Construction LL m ALL Cttion Type: Single Family _ Z J 13 A DISTURBED AREAS TO BE REPAIRED IN KIND BY GENERAL CONTRACTOR. U lT Project Type: Addition U ;•O 14 MINOR ITEMS SUCH AS PATCHING, BLOCKING, TRIM, ETC. SHALL BE PERFORMED AS REQUIRED Project Sub Type: None ° LU TO MAKE THE: WORK COMPLETE WFfETHER SHOWN OR NOTED ON THE DOCUMENTS OR NOT. Glazing Area: 9% REPLACE PVC, TRASH J UJ M / I I z' (n Climate Zone: 4a(5572 HDD) ENCLOSURE � — Z � 15 CONTRACTOR SHALL MAINTAIN THE SITE IN A SAFE, GLEAN AND ORDERLY FASHION FOR THE DURATION OF All Electric: false (COORD. IN FIELD) / J THE CONSTRUCTION PERIOD. ALL MATERIAL (CONCRETE, FILL, WOOD, ETC AND CONSTRUCTION DEBRIS TO Is Renewable: false BE REMOVED AT THE END OF EACH WORK DAY AND SHALL BE DISPOSED OF REGULARLY AT A LEGAL OFF Has Battery: false MODIFY STEPPING STONE G ® G 20' I 10'-3" BEL6IUM BLOCK TRASH/ AG LOT No. 345 SITE WASTE FACILITY.. Has Charger: false A LO No 346 Y NEW WORK ' 16 THE GONTRAGTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE INCURRED ANYWHERE WITHIN THE Has Heat Pump false W GENERATOR / SINGLE HATCH INDICATES AREA OF 15T BOUNDARIES OF THE PROPERTY AND ANY DAMAGE SHALL BE PROMPTLY REPAIRED TO THE 5AT15FACTION (COORD. IN FIELD) _I 17- WAL FLOOR INTERIOR ALTERATION (345 S.F) OF THE ARCHITECT AND OWNER. Construction Site: Owner/Agent: Designer/Contractor: RELOCATED A/G UNIT EXIST. DOUBLE HATCH INDICATES AREA OF 2ND RE OCA E FIELD) = COMPOSITE EXIST. FLOOR INTERIOR ALTERATION (345 S.F) 17 NOTATIONS ON ANY PLAN, ELEVATION, SECTION OR DETAIL ARE APPLICABLE TO 710 Old Menhaden Road Dan&Sophie McNeill Stephen Scheibly i DECK BRICKI ALL PLANS, E•LEVATION5, 5ECTIIONS AND DETAILS. Cutchogue,NY 11935 710 Old Menhaden Road 255 Main Street NEW A/C UNIT /choque,NY 11935 Diversified Design Associates,Architects P.C. 1— HT. O'—8 PATI EXIST. 2nd STY. Cut Cut (755)594-7734 Huntington,NY 11743 1 (COORD. IN FIELD) BALCONY TO BE RENOVATED +44 IS PROVIDE 1/2" W.R. GYPSUM WALLL BOARD ALL WALLS/GEILIN65 OF "WET" AREAS sophie.mcneill@hotmail.com 631.271.5400 x 102 / 0-q ry OVER PORCH TO REMAIN sscheibly@ddany.net (SHOWERS, TUBS, ETC) Q cI";, i6ti. , ,,._ STRUCTURAL KUROS SORBI-AVA ENGINEERING NEW BASEMENT EGRESS w/RESS STAIR DRYWELL (77.6 S.F) - I ENGINEER: 169 COMMACK ROAD Iq ALL NEW APPLIANCES ARE AS SELECTED BY OWNER AND SHALL BE INSTALLED ".'' SUITE H-362 BY THE CONTRACTOR AS PER: THE MANUFACTURERS 5PEGIFIGATION5. Envelope Assemblies F _ Oil COMMACK, NY 11725 h O 2„ O 4 j NOt�710 <,, �6 C I E 631-355-5556 _ SHALL � �j2'STORY�,;' Prop. Req. RPRT�IE +.x; I 20 AND INSSTRALLED BY THE IGENER:AL CONTRACTOR.SELECTED BY OWNER Gross Area or Cavity Cont. U_ U_ Prop. Req. all //�DY�lELL1N { ; I m I 21 TYPE/LOCATION/EXTENT OF ALL NEW INTERIOR FINISHES (PAINT, CERAMIC TILE, Assembly Perimeter R-Value R-Value Factor/ Factor/ UA UA HATCH INDICATES AREA OF FIRST FLOOR '' ' 3 I FE. O'-q"+W, - VINYL TILE, CARPET, ETC) 51­! WN AkLL BE AS 5ELECTED/DIREGTED BY OER. F-Factor F-Factor GARAGE ADDITION (117.74 SF) - Ceiling: Flat Ceiling or 294 30.0 0.0 0.035 0.026 10 8 03 IL Scissor Truss 03 n I J J DOUBLE HATCH INDICATES AREA OF 22 ALL ELEGTRIGAL, PLUMBING AND H.VA.C. TO BE IN STRICT ACCORDANCE WITH THE - INTERNATIOKL RESIDENTIAL G:ODE AND ALL APPLICABLE LOCAL REGULATIONS. Floor:All-wood 261 30.0 0.0 0.033 0.047 9 12 GARAGE CONVERTED TO HABITABLE 27-4 N JoistlTruss I SPACE (178.47 S.F.) / 14'-6 W " 21.0 0.0 0.057 0.060 34 36 R/0 WOOD PORC, FE. 0'-q" Wall:Wood Frame,16 673 ±W, 23 INSTALL SMOKE DETECTORS AIND CARBON MONOXIDE DETECTORS IN ACCORDANCE O.C. - SOLID HATCH INDICATES AREA OF WITH ALL STATE AND LOCAL CODE REQUIREMENTS. window:wood Frame 73 0.310 0.320 23 23 SECOND FLOOR ADDITION (222 5.F) %/% V_ r ;y SHGC:0.3 24 PRIVATE 6AIZAGE SHAM BE SEPARATED HORIZONTALLY AND VERTICALLY FROM wall 1:wood Frame, 122 15.0 0.0 0.077 0.060 9 7 MODIFY PLANTING BED AS DIRECTED o� MODIFY, REPAIR a( REPLACE EXISTING DECK, r s " 16"o.c. BY OWNER / WALKWAY $ STONE LANDSCAPE WALL AS THE RE:SIDEWSE WITH NOT LE55 THAN /e TYPE X GYPSUM BOARD � I READ. BY NEW WORK HATCH INDICATES AREA OF FIRST FLOOR / 25 OPENINGS FROM A PRIVATE GARAGE INTO A RESIDENCE SHALL BE EQUIPPED WITH ; LLL. tj a LAUNDRY ROOM ADDITION (83.25 SF) 15 A 20 MINUTE FIRE RATED DOOR A55EMBLY WITH A SELF-CLOSING DEVICE. :. .�. t �4 26 CONTRACTOR TO SCHEDULE AND OBTAIN ALL NECESSARY UTILITY STAKE OUTS I.e. - Q _ J WATER, ELECTRIC, SEPTIC d 6/A5 PRIOR TO COMMENCING WITH ANY SITE WORK. The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES 0 — — DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. NOT provide an estimate of energy use or cost relative to a minimum-code home. Y) MIN. REQ'D. SIDE Iu - YARD SETBAGK 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade CO �[ z assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. °O • Q O I P. 631.27E.5400 WWW.DDANY.NET �` �I Copyright ©2025 All Rights Resented. G L I •I I G 06 P I G � S I6 I �t G FZ I T R I A � Q W ( _ SEAL: PROJECT NORTH: Compliance Statement ry �� � m n ,,-::-,a�y-,,; ., SUBJECT TO ICE 13AMER FLOOD ,Z GROUND W1HO DESIGN `585MIG AIR MEAN The proposed building design described here is consistent with the building plans,specifications,and other calculations 0 DAMAGE BY WINTER 11NpC-RLAY- HAZARDS _ SNOW DF51GN FFZEE:ZIN ANNU submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in T010- SPECdAi_ DE516N MENT < (V LOAD 5P® 6RePHIG Wl$� gpME GA hFJ1TFB2 FR05T TERMITE ZONE X INDEX TEMP. REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. R>PIU EHWT5 RIETAO i �5' LNG LDEPTH TEMP REQUIRED MIN. REOV. SIDE X +il Z EFFECTIVE YARD SETBACK LLI 0 +I Z FIRM: MOD. Oq/25/2oOq 1500 O y 1 ry , \/oh O�. O ry 30 PSF 128 1�10 NO NO "B" 3'-0" TO IS YC-5 PANEL #: OR 50.8 g x FE. O 10 ± E. LE55 Name -Title Signature Date �• :_ :� HEAVY 36103GO16 TH15 PROJECT 15 IN COMPLIANCE WITH: 112.58 N STACKED STONE WALL � PROJECT TITLE: THE RESIDENTIAL. CODE OF NEW YORK STATE - 2020 EDITION N y7- L ° i2 n �'6S ± AFPA WOOD FRAME CONSTRUCTION MANUAL FOR ONE AND TWO FAMILY DWELLINGS - 2018 EDITION �� N "7� 54 � W RENOVATIONS Report Title: McNeill Residence Report Date: 8/29/25, 11:32 AM 2 of 11 o N�V ALTERATIONS TO THE: THE ENERGY CONSERVATION GORE OF NEW YORK STATE- 2020 EDITION IN SRO yT ���GMENHADENMcNEILL® THE ZONING CODE OF THE TOWN OFF SOUTHOLD NFPA -10 STANDARD - 2017 EDITION •��o, OLD RESIDENCE NATIONAL ELECTRICAL CODE 20I7 '�I U L15T OF DRA II V��5 IA �H IT E G T A L 517E PLAN SURVEYORS,5Y055ET NY DAPTED FROM SURVEY AND DATED MAY 26, 20P25 RET'ARED BY ISLAND WIDE LAND GS-I 710 OLD MENHADEN ROAD S G A L E : I 51TE PLAN, GENERAL NOTES, RESC14ECK COMPLIANCE CERTIFICATE 2 0 o" GS = - CUTCHOGUE , NEW YORK 11935 SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DE-56RIPTION A-001 6RO55 FLOOR AREA DIAGRAMS, LOT C•OVERA6E DIAGRAM DRAWING TITLE: A-100 GENERAL NOTES, PLUMBING RISER DIAGRAM, PLUMBING FIXTURE SCHEDULE, REQUIRED 516N POSTING ZONING I NFORMAT 1 ON GENERAL NOTES x A-101 FIRST FLOOR DEMOLITION PLAN, NOTES AND DETAILS PROPERTY ADDRESS: 710 OLD MENHADEN ROAD TAX MAP NO. SECT. III BLOCK 4 LOT Iq L 15T OF DRAW I NG5 X-X SECTION REFERENCE O DOOR O REFERENCE 1 ARCHITECTURAL SITE PLAN SEE DWG. AS NOTED X ELEVATION TAG SEE X -SEE DOOR A-102 SECOND FLOOR DEMOLITION PLAN, NOTE I GUTGHOGUE, NY IIg35 PROPERTY ZONING: ZONE R-40 DWG. AS NOTED SCHEDULE A-103 FOUNDATION PLAN, NOTES AND DETAILS UNDERPINNING DETAIL ITEM PERMITTED/ REOU I RED PROVIDED COMPLIANCE RESGHEGK COMPLIANCE CERT. A-104 FIRST FLOOR GON5TRUGTION PLAN, NOTES AND DETAILS MINIMUM LOT AREA 40000 S.F. I1,31633 S.F. * DOES NOT COMPLY DETAIL REFERENCE- NOTE REFERENCE- SEE WINDOW REFERENCE X O X A-105 SECOND FLOOR CONSTRUCTION PLAN, NOTES AND DETAILS MINIMUM LOT WIDTH 150 FEET qq'-7" * DOES NOT COMPLY SEE DWG. AS NOTED XXX NOTE LE6END FOR - SEE WINDOW X-X ADD'TL INFO. SCHEDULE A-106 ROOF PLAN, NOTES AND DETAILS, ROOF VENT DETAIL MINIMUM LOT DEPTH 115 FEET 225.82' COMPLIES A-101 SECOND FLOOR FRAMING PLAN, NOTES AND DETAILS MINIMUM FRONT YARD SETBACK 50 FEET 761-4Y2" COMPLIES DRAWN BY: 5DE SHEET NO. BENCHMARK xx A ELEVATION REFERENCE - SEE TAG NALL TYPE REVISION A-105 ROOF FRAMING PLAN NOTES AND DETAILS MINIMUM SIDE YARD 5ET13ACK 15 FEET q-10 DOES NOT COMPLY r1 WALL TYPES CHECKED BY: S.1S A-200 EXTERIOR ELEVATIONS MINIMUM SIDE YARD AGGREGATE 35 FEET 30'-2 3/4" * DOES NOT COMPLY ROOM a FURNITURE / EQUIPMENT PLUMBING FIXTURE A-201 EXTERIOR ELEVATIONS MINIMUM REAR YARD SETBACK 50 FEET NUMBER REFERENCE - SEE 80 I Y4 COMPLIES DATE: 10.20.25 R • 101 TAG REFDUI ERENCE XO REFERENGE-5EE A-300 GRO55 SECTION, MODIFIED BIRDS MOUTH DETAIL MAXIMUM LOT WVE:RA6E 20% (3,863.27 5.F) 18.5 % (3,377.1 S.F.) GOMPLIES CSM1 PLUMBING FIXTURE SCALE: A5 NOTED p�-4O0 STRAPPING DETAILS MAXIMUM GR055 FLOOR AREA 2,100 S.F. + (12.55K OF q,316.33) = 3,264.54 S.F. 3,256.g3 S.F. COMPLIES SCHEDULE A-401 NAILING SCHEDULE MAXIMUM BUILDING HEIGHT 2 STORIES OR 35 FEET 2 STORIES; 31'-7" COMPLIES PROJECT NO. 2515 E-100 FIRST FLOOR LIGHTING PLAN NOTE: TH15 PROPERTY IS AN EXI5TIN6 NON-CONFORMING LOT = EXISTING NON GONFORMIN6 E-101 SECOND FLOOR LIGHTING PLAN NOTE: SEE A-001 FOR FLOOR AREA AND LOT GOVERA(5E DIAGRAMS 777 LOT COVERAGE CALCULATION: V + GROSS FLOOR AREA CALCULATION: THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY PERMITTED LOT COVERAGE = 20% LOT AREA THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE,AND ARE AND SHALL 41 30'-2 5/8" f LOT AREA = Iq,316.33 5F REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE LOT AREA = Iq,316.33 S.F. 1,1,316.33 5F x 20 % = 3,863.21 5.F. PERMITTED INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER 6RO55 FLOOR AREA (LOTS UP TO 20,000 S.F.) LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE ALLOWABLE: 2,100 S.F. + 12.5% OF LOT AREA IN EXGE56 OF 10,000 S.F. EXISTING LOT COVERAGE AREAS: ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL 2,100 S.F. + (125% OF q,316.33) = 3,26454 S.F. \ COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. EXISTING TWO STORY DWELLING (INGLUDIN6 GARAGE) = 1,675.36 S.F. IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION FIRST FLOOR: EXISTING R.O. PORCH #1 = 428.16 S.F. OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I \ \ EXISTING R.O. PORCH #2 = 66.35 S.F. ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING AREA A = 14'-5" x 28'-5 3/8°= 410.12 5F EXISTING DECK = 251A( S.F. ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION'ALTERED BY AREA B = 27'-4 5/g" X 22'--I 5/s"= 61 q.88 5F I FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE 15TING VINYL SHED EXISTING VINYL SHED = 10131 S.F. SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION AREA G = 30'-2 5/a" x Ib'-II Y8" = 51152 5F 101.31 5F EXISTING SWIMMING POOL = 7g2.85 S.F.O AREA "I" AREA D = 8'-4 Y8" x 7'- 3 5/8" = bOA3 5F LAW ARTICLE 147 ARCHITECTURE,SECTION 7307) EXISTING STACKED STONE WALL #I 7= .31 S.F. AREA E = 6-o,Y2" x 5� Y4 II ' = 35.87 5F N6 EXI5T7 STACKED STONE WALL #2 = 41.6 S.F. AREA F = 10-7 x 3-b = 37.04 5F ISSUANCE: FIRST FLOOR EXISTING TOTAL = Ib75.36 5F I TOTAL EXISTING LOT COVERAGE AREA = 3.377.1 S.F. NO. DATE: DESCRIPTION: SECOND FLOOR: I f PROPOSED LOT COVERAGE AREAS: 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING -17VISED PER OWNER CHANUES PROPOSED GARAGE ADDITION = 111.14 S.F. ® 04.09.26 ADD BASEMENT EGRESS STAIR AREA 6 = 22'-6 3/4" x 28'-6 �/e" = 644.68 5F _ AREA H = 13'-8 Y2' x 6-2 'Yb" = 181.4q 5F AREA "H" 1 PROPOSED BASEMENT EGRESS STAIR = 77.6 S.F. AREA 1 = 30'-2 5/e' x II'-0" = 332.41 5F m I TOTAL PROPOSED LOT COVERAGE AREA = 2-18.6 S.F. _ SECOND FLOOR EXISTING TOTAL = 1,158.58 SF d) _ AREA "6" " " EXISTING GRO55 FLOOR AREA TOTAL = 2 833.g4 SF EXISTING TOTAL LOT COVERAGE AREA= 3.655.7 S.F. t 3,863.2-1 S.F. (GOMPLfES) r AREA L LOT COVERAGE % = 8 < O GO IE5 PAYER PAT10 EXISTING SWIMMING N PROPOSED FIRST FLOOR ADDITIONS: (0 GRADE) POOL 1 .q X' 2 X' ( MPL ) 7g2.85 5F AREA J = 14'-5" x 8'-2" = 117.74 5F AREA K = 13'-10 Y2" x 6'-0" = 53.25 5F I I FIRST FLOOR ADDITIONS TOTAL = 200.gq 5F PROPOSED SECOND FLOOR ADDITION: EX15T1N6 DECK 257.g16 5F AREA L = 13'-IO Y2" x Ib'-0" = 222D 5F I � PROP05ED ADDITIONS TOTAL = 422.gq SF 13'-10 I/2" 22'-6 3/4" 13'-8 I/2" TOTAL PROPOSED 6RO55 FLOOR AREA= 325663 S.F. 1 PROPOSED BASEMENTr E6RE55 EXISTING BRICK 3256.g3 < 326454 S.F. (COMPLIES) STAIR-17.6 S.F. PATIO 15TIN6 R0. PORCH #2 (0 GRADE) 66.35 5F SECOND FLOOR AREA DIAGRAM PROP05M LAUNDRY ,ADDITION I 83.25 5F 13'-10 1/2" 30'-2 5/8" 6-0 1/2" / I m AREA "F" EXISTING TP40 STORY DWELLING 1,675.36 5F PROP05ED GARAGE -� ADDITION STRUCTURAL KUROS SORBI-AVA ENGINEERING 111.14 5F I I ENGINEER: 169 COMMACK ROAD EXISTING R.O. PORGH#1 SUITE H-362 AREA "ON � ( 428.16 SF COMMACK 631-355 5556 725 AREA "K" AREA "Ell `n / AREA "D" u� , r- EXISTING DRIVEWAY a� AREA "B" AREA "A" N I DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 P. 631.271.5400 WWW.DDANY.NET Copyright ep 2025 All Rights Reserved. SEAL: PROJECT NORTH: EXI5TIN6 5TAGKED I5TIN6 5TAGKED ^ n / STONE WALL#1 ( STONE WALL #2 W 7.31 5F 47.8 SF i N AREA "J" 14'-5" 27'-4 5/8" 8'-4 I/8" PROJECT TITLE: RENOVATIONS & ALTERATIONS TO THE: FIRST FLOOR AREA tPIAGRAM McNEILL RESIDENCE I=LCOR AREA 1:) 1A6RAM5 HATCH INDICATE-5 PROPOSED AREA 2 1 LOT CICIVERA6F. 1:) ( A&RAM 710 OLD MENHADEN ROAD AOOI I/8" = I'-o" AOOI me, = r-oll CUTCHOGUE , NEW YORK 11935 DRAWING TITLE: FLOOR AREA D I AGRAM5 DRAINAOE r=,,A L�U L A T 10 N 5 LOT COVERAGE DIAGRAM ZONE-i -7-7.6 50. FT. FORMULA = AREA x 2" RAINFALL x RUNOFF COEFFICIENT = CUBIC FEET OF RETENTION REQU I RED ZONE-I ll h S.E. x 10.1-7 x 1.0 = 13.1 1�1 CUBIC FEET DRAWN BY: 5DE SHEET NO. USING 4'-0" D I A. RINGS AT 5.12 CUBIC FEET PER FOOT OF DEPTH CHECKED BY: 5,J5 13.1 Q CUBIC FEET / 5.-12 = 1.51 FT. OF DEPTH REOU I RED = DATE: 10.20.25 A e®® PROVIDE (l) 4'-0" D I A. x 2'-0" DEEP DRYWELL SCALE: A5 NOTED PROJECT NO. 2515 xxr�'`''K«,�^ " °`.'u� >i,k`m�Pf'• „ :,,,r=4 77 S I TE WORK FRAM I NG - CONSTRUCTION LUMBER AIR BARRIER AND INSULATION INSTALLATION 6 : u ". r . "0 SIGN w/ STROKE WIDTH OF Y2' GURGLE SIGNS MAY BE PURCHASED AT , 1. STAKEOUT 15 TO BE PERFORMED BY A LICENSED SURVEYOR. 5TAKIN6 AND LAYOUT I FRAMING LUMBER SHALL BE SQUARE-EDGE, 5TRA16HT, SOUND, WELL-SEASONED, WITH A [REFER TO TABLE R402.4.1.1 OF THE RESIDENTIAL GORE OF NEW YORK STATE] AND CONTENTS ARE TO BE REFLECTIVE WWW.5AFE-T-50LUTION5.COM OR THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY ARE TO ESTABLISH ALL LINES AND 'BENCHMARKS AND VERIFY ALL CIVET! DATA ON RED COLOR PM5 #187, BACKGROUND TO WWW.5TIGKY5GRAPHICS.COM OR SIMILAR SITE. THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE,AND ARE AND SHALL MAXIMUM MOISTURE CONTENT OF NINETEEN (Iq%) PERCENT AT THE TIME OF I 5U TIQ INSTALLATION Q REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE DRAWINGS. IN CASE OF DISCREPANCY, RECEIVE CLARIFICATION FROM ARCHITECT INSTALLATION. LUMBER SHALL BEAR THE GRADE AND TRADEMARKS OF THE GOMFON NT AIR BARRIER CRITERIA CRITERIA BE REFLECTIVE WHITE INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER CONSTRUCTION DE SUBJECT TD PRIOR TO PROGEEDIN6. ASSOCIATION BY NH05E RULES IT IS PRODUCED, SIZES INDICATED ARE NOMINAL LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE - STANDARD SIZES. GENERAL REQU AIR BARRIER SHALL BE E PROVISIONS OF IRGNY5 ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL INSTALLED IN THE BUILDING ENVELOIPE AIR—PERMEABLE INSULATION SHALL NOT BE COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. 2. EXCAVATE AND BACK FILL FOR WORK INDICATED ON DRAWINGS. STOCKPILE 2 FRAMING LUMBER SHALL BE 5TRE55-RATED DOU6LA5 FIR LARCH NO. 2 WITH A THE EXTERIOR THERMAL ENVELOPE CONTAINS USED AS A SEALING MATERIAL LOCATION DESIGNATION TOPSOIL OBTAINED FROM STRIPPING BUILDING SITE AND STOCKPILE ALL EXCAVATED STRESS RATING OF 575 P51 RESPECTIVELY FOR BENDING FOR 51N6LE MEMBER USE A CONTINUOUS AIR BARRIER IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION MATERIAL AT THE SITE. REAKS OR JOINTS I THE AIR BARRIER SHALL OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I AND q0 PSI MINIMUM FOR SHEAR. E SEALED �. ;t ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING 3. NEW AND EXISTING BACK FILL MATERIAL AND TOP501L ARE TO BE FREE OF WEEDS, 3 PROVIDE DOUBLE FRAMING AROUND ALL OPENINGS, UNDER ALL PARALLEL WALL5 AND THE AIR BARRIER IN ANY DROPPED CEILING/ \ NOTE: SIGN I5 TO BE AFFIXED TO EXTERIOR ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION'ALTERED BY' TREE ROOTS, ROCKS AND DEBRIS. UNDER BATHTUBS. PROVIDE SIMF'SON HANGER CONNECTIONS AT ALL FLUSH CEILING/ATTIC SOFFIT SHALL BE ALIGNED w/THE ]INSULATION ` ELECTRICAL BOX. SIGN I5 TO BE OF STURDY, FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE THE INSULATION IN ANY DROPPED CEILING/ NO FADING, WEATHER RE-515TANT MATERIAL. SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION STRUCTURAL LOAD BEARING CONDITIONS. AND ANY GAPS IN THE AIR BARRIER SHALL SOFFIT SHALL BE ALIGNED w/THE AIR LAW ARTICLE 147 ARCHITECTURE,SECTION 7307) 4. ALL SURPLUS MATERIAL THAT 15 UNSUITABLE FOR BACK FILL MATERIAL SHALL BE 4 PROVIDE SOLID BRIDGING BETWEEN JOISTS AT 6'-0" o.c. MAXIMUM. E SEALED. BARRIER. REMOVED FROM THE SITE. ACCESS OPENIN65,DROP DOWN STAIRS OR KNEE5 UNLESS OTHERWISE NOTED, ALL WINDOW AND DOOR OPENINGS SHALL HAVE (2) 2" X 10" SPACES WALL DOORS ONDITIOT�IED ATTIC IREOU IRr=l;) S 1 ON f"0571 N 6 ISSUANCE: 5. PROTECT ALL TREES WITHIN EIGHT FEET OF THE BUILDING. HEADERS ABOVE. A SHALL BESEALEDLED• WALLS THE JUNCTION OF HE FOUNDATION AND SILL CAVITIES w/CORNERS AND HEADERS of NO. DATE: DESCRIPTION: b. PROPER APPROVAL MUST BE OBTAINED BEFORE GOVERIN6 (BACK FILLING) ANY 6 ALL PLATES IN CONTACT WITH FOUNDATION WALLS TO BE PRESSURE TREATED AND ATE SHALL BE SEALED- FRAME KALLSLY FIL�LIN�G THE EINSULATED A AIOO 3" = I'-0" 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING EXCAVATED WORK. HAVE CONTINUOUS METAL TERMITE SHIELDS. PLATES SHALL BE BOLTED TO JUNCTION OF THE TOP PLATE AND THE MATERIAL HAVING A THERMAL RESISTANCE " n TOP OF EXTERIOR WALLS SHALL BE SEALED. ® 040926 _17VISED PER OWNER CHANGES FOUNDATION WALL5 WITH 5/8 DIAMETER BOLTS AT 48 o.c. MAXIMUM AND I-0 KNEE WALLS SHALL BE SEALED. OF R-3 PER INCH MINIMUM. . . ADD BASEMENT EGRESS STAIR 7• CONTRACTOR 15 RESPONSIBLE TO CONTACT ALL UTILITY COMPANIES AND REQUEST MAXIMUM FROM EACH CORNER. BOLTS MUST BE EMBEDDED A MINIMUM OF 7" INTO EXTERIOR THERMAL ENVELOPE INSULATION UTILITY STAKEOUTS PRIOR TO COMM4ENGIN6 WITH EXCAVATION. FOUNDATIO N&N WALLS. FORGE MORTAR INTO THE JOINT BETWEEN SILL BOTTOM AND FOR FRAMED WALLS SHALL BE INSTALL I 1221 �.TUSGUi�i_IN SUBSTANTIAL CONTACT AND GONTI LED TOP OF FOUNDATION. ALIGNMENT WITH THE AIR BARRIER CONCRETE AND FOUNDATION 7 ALL SUB-FLOORING, WALL AND ROOF 5HEATHIN6 SHALL BE EXTERIOR GRADE CDX WINDOWS,5KYL AGE BETWEEN WINDOW/DOOR JAMBS I. ALL CONCRETE OR MASONRY WORK SHALL BE DONE DURING TEMPERATURES OF 32 PLYWOOD, 511JIB-FLOORIN6 - 3/4", WALL 5HEATHING - 1/2", ROOFING 5HEATHIN6 - 5/8". AND DOORS AND FRAMING AND SKYLIGHTS AND FRAMING RE5FON515LE FOR: DEGREES FAHRENHEIT AND RISING T-1INIMUM. SHALLBE QED TAG FIXTURE LOCATION SPECIFICATION PURCHASE 8 ALL BUILT-UP WOOD GIRDERS AND HEADERS SHALL NOT HAVE ANY SPLIT ON THE RIM JOISTS RIM JOISTS SHALL INCLUDE THE AIR:BARRIER RIM JOISTS SHALL BE INSULATED INSTALLATION 2• NO CONCRETE SHALL BE PLACED ON FROZEN SURFACES. WIDE FACE OF ANY MEMBER GREATER THAN 1/2 TIMES THE WIDE FACE. Cl ALL EXPOSED WOOD FOR SOFFITS, OVERHANGS, ETC. SHALL BE APPROVED TO BE SELECTED 3. NO ADDITIVES SHALL BE ALLOWED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT. FLOOR FRAMING CAVITY INSULATION O LAVATORY � OWNER FLOORS THE AIR BARRIER SHALL BE INSTALLED AT I RENO BATH #I EXTERIOR GRADE. (INCLUDING ANY EXPOSED EDGE OF INSULATION] BE INSTALLED TO MAINTAIN PERMANENT FAUCET CONTRACTOR CONTACT WITH THE UNDERSIDE OF 4. ALL CONCRETE WORK SHALL CONFORM TO REQUIREMENTS AND RECOMMENDATIONS 10 ALL FLUSH FRAMING CONNECTIONS SHALL BE MADE WITH J015T HANGERS, FRAMING C7 RA� 4 SUBFLOOR DECKING,OR FLOOR FRAMING HALL �G TO BE SELECTED OWNER OF AGI-301-gq ■SPEGIFIGATIONS FOR STRUCTURAL GONGRET'E FOR BUILDINGSn CAVITY INSULATION SHALL BE PERMITTED ANCHORS, OR RAFTER ANCHORS OF MINIMUM 18 GAUGE PRIME GALVANIZED STEEL AS CANTILEVERED TO BE IN CONTACT WITH THE TOP SIDE OF 2 TOILET RENO BATH #I (fc'=3000 P51). ALL EXPOSED 5LAB5, GARAGE SLABS AND STEPS SHALL BE 5500 MANUFACTURED BY "SIMPSON" STRONG TIE GONNEGTOR5. 51ZED AND NAILED AS PER FLOORS) SHEATHING,OR CONTINUOUS INSULATION CONTRAGTOR P51 AIR-ENTRAINED. REINFORGIN6 STEEL SHALL CONFORM TO A5TM A-615 GRADE 60 REACTIVE LOAD. INSTALLED ON THE UNDERSIDE OF FLOOR TO BE SELECTED SHOWER BASE 4 OWNER FRAMING AND EXTENDS FROM THE BOTTOM 3 RENO BATH #I II NAILING TO CONFORM TO SCHEDULE INDICATED IN THE WOOD FRAME CON5TRUGTION FR THE TOP OF ALL D5 FROM T FLOOR SHOWER BODY 5. PROVIDE ALL SLEEVES AND FOUNDATION VENTS AS REQUIRED BY RESIDENTIAL MANUAL FOR ONE AND TWO FAMILY DWELLINGS UNLESS OTHERWISE NOTED. FRAMING MEMBERS CONTRACTOR CODE OF N.Y.5. TO BE SELECTED WHERE PROVIDED INSTEAD OF FLOOR O UTILITY SINK OWNER n 12 LEAVE I/I6" SPACE AT ALL PLYWOOD PANEL END JOINTS AND 1/8" SPACE AT ALL CRAWL SPACE EARTH IN UNVENTID GRAVNL SPARES INSULATION, INSULATION SHALL BE 4 FAUCET NEW LAUNDRY b. UNLESS OTHERWISE INDICATED, ALL FOUNDATION FOOTING ARE TO BE MINIMUM 12 PANEL EDGE JOINTS. SHALL BE COVERED WITH A G1A55 I VAPOR PERMANENTLY ATTACHED TO THE CONTRACTOR DEEP X 24 WIDE, CENTERED UNDER THE FOUNDATION WALL (OR AS PER DETAILS) RETARDER WITH OVERLAPPING JOINTS TAPED PERMANENTLY WALLS O EXISTING TO BE RE-USED 13 PROVIDE 50LID BLOGKING FROM TOP/GIRDER OR FOUNDATION WALL TO THE 5 KITCHEN SINK 4 RENOVATED OWNER -1. PROVIDE TWO #5 DEFORMED BARS CONTINUOUS IN THE FOOTING AND A CONTINUOUS UNDER51DE OF FLOOR AT WOOD POSTS. ALL WOOD POSTS SHALL BE 4"X4" MINIMUM. SHAFTS, FTs,PANTY PENETRATI AND FAUCET KITCHEN FLUE SHAFTS OPENING TO EXTERIOR OR CONTRACTOR 2"x4" KEY BETWEEN THE FOOTING AND FOUNDATION WALL EXCEPT A5 NOTED UNCONDITIONED SPACES SHALL SE!SEALED TO BE SELECTED OTHERWISE. 14 NOTATIONS ON ANY PLAN, ELEVATION, SECTION OR DETAIL ARE APPLICABLE TO ALL BATTS IN NARROW CAVITIES SHALL BE GUT O H05E BIB EXTERIOR (I AT OWNER PLANS,ELEVATIONS, 5EGTION5 AND DETAILS. NARROW GAVI FRONT I AT REAR) 8. PROVIDE 5/8" X 12" ANCHOR BOLTS. ALL FOUNDATION WALLS SHALL HAVE ANCHOR To FIT,OR NARROW CAVITIES SHALL BE GONTRACTOR FILLED BY INSULATION THAT ON BOLTS SET APPROXIMATELY ONE FOOT FROM EACH CORNER AND SPACED 48" ON 15 ACCORDANCE WITH WESTERN WOODS GUIDELINES FOR DIMENSIONAL LUMBER.JOISTS ARE NOT TO BE NOTCHED. ALL HOLES FOR PLUMBING MUST BE DONE IN INSTALLATION READILY CONFORMS TO THE O LAVATORY 4 NEW BATH #2 TO BE SELECTED OWNER CENTER. THERE SHALL BE ANCHOR: BOLTS ON EITHER 51DE OF ANY OPENING AND AT AVAI CAVITYSPACE 7 LEAST TWO BOLTS IN ANY ONE SILL. GARAGE sEPA T< ALIN6 SHALL BE PROVIDED �ETV�N FAUCET CONTRACTOR 16 INSTALL FIRE5TOPPING AT ALL REQUIRED LOCATIONS COMPLY WITH GOVERNING THE GARAGE AND CONDITIONED SP/AGES TO BE 5ELECTED CODES. RECESSED LI ESSED LIGHT FIXTURES INSTALLIED IN THE RECESSED LIGHT FIXTURES INSTALLED IN y�L I�J1.I(� OWNER q. PROVIDE PREMOLDED JOINT FILLER BETWEEN SLABS AND FOUNDATION WALLS. THE BUILDING THERMAL ENVELOPE BUILDING THERMAL ENVELOPE SHALL BE SHALL TOILET NEW BATH #2 17 ALL HORIZONTAL FRAMING BEARING ON BEAMS, GIRDERS OR PARTITION TOP PLATES To THE DRYWALL BE AIR TIGHT AND IG RATED. CONTRACTOR 10. ALL FOOTINGS SHALL BEAR ON UNDISTURBED SOIL WITH MINIMUM BEARING CAPACITY SHALL BE LAPPED 4" MINIMUM. TO BE SELECTED GATT INSULATION SHALL BE GUT NEATLY T SHOWER BODY OWNER OF I TON5/5F BEARING CAPACITY. (CONTRACTOR SHALL HAVE THE LEVEL OF PLUMBING AND ]RING q NEW BATH #2 FIT AROUND WIRING AND PLUMBING IN ACCEPTABLE BEARING STRATA VERIFIED IN FIELD. 18 ALL HEADERS TO BE SUPPORTED BY MINIMUM (2) 2"x4" OR 4"x4" POSTS UNLE55 EXTERIOR WALL5,OR INSULATION THAT ON CONTRACTOR OTHERWISE NOTED. INSTALLATION READILY CONFORMS TO TO BE SELECTED Ii. ALL POURED CONCRETE SLABS ARC TO BE 4" THICK WITH 6X6, 10/I0 W.W.M. OVER 6 AVAIL.ABLE SPACE SHALL EXTEND BEHIND Ip LAVATORY 4 NEW BATH #3 OWNER MIL. POLYETHENE VAPOR BARRIER OVER 6" COMPACTED GRAVEL. UNLE55 INSULATION / VENTILATION NOTES PIPING ND IRIN6 FAUCET -CONTRACTOR OTHERWISE NOTED. 5HONER/T UB O THE AIR BARRIER INSTALLED AT E.X(TERIOR RECESSED LIGHT FIXTURES INSTALLED IN THE BUILDING THERMAL ENVELOPE SHALL TO BE 5ELEGTED EXTERIOR WALLS ADJACENT TO SHOWERS ANiD TUBS OWNER i THI5 PROJECT HAS BEEN DESIGNED TO MEET THE REQUIREMENTS OF THE NEW YORK ALL SEPARATE THEM FROM.THE SHOWERS BE AIR TIGHT AND IC RATED. I I TOILET NEW BATH #3 12. ALL CONCRETE SHALL BE VIBRATED IN ACCORDANCE WITH STANDARDS SET FORTH STATE ENERGY CODE. THERE SHALL BE NO DEVIATION FROM THE R VALUES INDICATED AND TUBS GONTRACTOR STRUCTURAL KUROS SORBI-AVA ENGINEERING BY THE AGI AND C-�ENERALLY AGGE:PTED BUILDING PRACTICE. ENGINEER: 169 COMMACK ROAD ON THE DRAWINGS. TO BE 5ELEGTED ELEGTRIGAV THE AIR BARRIER SHALL BE INSTALLID BEHIND 12 SHOWER BASE 4 OWNER SUITE 13. ALL CONCRETE BLOCK SHALL CONFORM TO A5TM 0-10;MORTAR SHALL BE TYPE "M" 2 ALL PENETRATIONS THROUGH FLOORS AND RIM BOARDS FOR ELECTRICAL AND PHONE B BOX ON ELECTRICAL OR COMM UNICATIONS BO)XE NEW BATH #3 H-362 5 OR SHOWER BODY CONTRACTOR COMMA -3 11725 MEGHANIGAL/PLUMBING AGGES5 ARE TO BE FILLED COMPLETELY WITH EXPANDING EXTERIOR AIR SEALED BOXES SHALL BE INSTALLED FOAM SEALANT. O HVAG REGISTER HVAG REGISTER BOOTS THAT PETIETRI:ATE 13 LAVATORY 4 RENO. BATH #4 TO BE SELECTED OWNER 631-355-5556 3 ALL CAVITIES AT WINDOW AND DOOR OPENINGS SHALL BE FILLED WITH MINIMAL BOOTS BIIALDIN&THERMAL ENVELOPE SHALL IBE FAUCET CONTRACTOR FOUNDATION WATERFROOFING SEALED TO THE SUBFLOOR OR DRYI^UALL EXPANDING FOAM SEALANT SPECIFICALLY DESIGNED FOR WINDOW AND DOOR USE. TO BE SELECTED 1- FOUNDATION WALL EXTERIOR SURFACES TO BE PROTECTED FROM BOTTOM OF CONCEALED BEN REQUIRED TO BE SEALED CONG:EA FI 14 WALL �C' RENO. BATH #4 OWNER 4 INSTALL INSULATION BAFFLES AT ALL VAULTED CEILINGS AND AT SOFFIT EN05 NEAR SPRINKLERS SPRINKLERS SHALL ONLY BE SEALED, IN A TOILET CONTRACTOR FOOTING TO WITHIN I OF FINISHED l6RADE WITH THE SPRAYED APPLICATION OF TOP PLATES TO PROVIDE UNINTERRUPTED AIR FLOW TO RIDGE VENT. MANNER THAT IS RECOMMENDED BY TI-E 'TUFF N DRI'. PROVIDE BACK FILL PROTECTION BOARD. BATHTUB 4 OWNER 5 MANUFACTURER CAULKING OR OTHER ADHESIVE TO BE SELECTED IS KENO , } RIDGE VENTS AS INDICATED ARE TO BE SHINGLE-VENT Ii AS MANUFACTURED BY SEALANTS SHALL NOT BE USED TO FILLL VOIDS O SHOWER BODY • BATH #4 "AIR-VENT" BETYEEN FIRE SPRINKLER COVER PLIATES AND « t AWALLS OR CEILINGS CONTRACTOR71 $ STRUCTURAL STEEL ROOFING NOTES 16 SHOWE_lR BASE 4 RENO BATH #5 TO BE SELECTED OWNER SHOWER BODY 'CONTRACTOR I. ALL STEEL WORK SHALL GONFORMI TO THE REQUIREMENT5 OF THE A15G I AS PER SECTION R0105.1.2 OF THE NY5 RESIDENTIAL BUILDING CODE AN IGE BARRIER "SPECIFICATIONS FOR DE516N, FABIRIGATION AND ERECTION OF STRUCTURAL STEEL 514ALL BE INSTALLED FOR ASPHALT 5HIN6LE5, METAL ROOF 5HIN6LE5, LAVATORY 4 TO BE SELECTED OWNER ` FOR BUILDINGS". STEEL SHALL CONFFORM TO A5TM A-572 (GRADE 50) AND A-501 MINERAL-5URFAGED ROLL ROOFING, SLATE AND SLATE-TYPE 5HIN6LE5, WOOD 17 FAUCET KENO. BATH #5 ,. CONTRACTOR ' 5HIN6LE5 AND WOOD SHAKES. THE IGE BARRIER SHALL WN515T OF NOT FEWER THAN TWO LAYERS OF UNDERLAYMENT CEMENTED TOGETHER, OR A SELF ADHERING TO BE SELECTED ; DEMIOL I TI ON POLYMER-MODIFIED BITUMEN SHEET SHALL BE USE IN PLACE OF NORMAL 18 TOILET RENO. BATH #5 OWNER " # REFER TO CONSTRUCTION DOGUMEf`yT5 FOR SPECIFIC DEMOLITION LOGATION/NOTES. UNDERLAYMENT AND EXTEND FROM THE LOWEST EDGES OF ALL ROOF SURFACES TO A CONTRACTOR ' s'> _•;, ,;r. POINT NOT LE-55 THAN 24 INCHES INSIDE THE EXTERIOR WALL OF THE BUILDING. ON ROOFS WITH SLOPE EQUAL TO OR GREATER THAN 8 UNITS VERTICAL IN 12 UNITS 2 WHERE EXI5TI N6 WALL5 ARE 5HOWTN TO BE REMOVED AND/OR NEW OPENI N65 ARE HORIZONTAL, THE IGE BARRIER SHALL AL50 BE APPLIED NOT LE55 THAN 36 INCHES DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. GALLED FOR IN EXISTING WA.LL5, TINE CONTRACTOR SHALL BRACE/5UPPORT ROOF, MEASURED ALONG THE ROOF SLOPE FROM THE SAVE EDGE OF THE BUILDING. CEILING AND/OR WALL PRIOR TO REMOVAL OF EXI5TIN6 WALLS, CEILING JOISTS AND 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 ROOF RAFTERS, AND MAINTAIN 5UGH CONDITION(5) UNTIL NEW HEADERS OR BEAMS FAINTING NOTES ARE INSTALLED AS SPECIFIED. EXIST. P. 631.271.5400 Copyright 02025 All Rights Reserved. WWW.DDANY.NET I EXTERIOR TRIM MUST BE PREPPED AND PAINTED AS PER MANUFACTURERS EXIST. 3" VENT 3 THE GENERAL CONTRACTOR 15 RESPONSIBLE FOR MAINTAINING OWNER THE STRUGTURAL REQUIREMENT5, IN SELECTED COLOR 3" VENT THRU j20OF SEAL: PROJECT NORTH: THRU OF I ROOF LINE INTEGRITY OF THE PROJECT AT ALIL TIMES. 2 ALL EXTERIOR COLUMNS AND COLUMN WRAPS MUST BE PREPPED AND PAINTED AS I 1 PER MANUFACTURERS REQUIREMENT5, IN OWNER SELECTED COLOR 4 ANY 0I5GREPANCIE5 RELATED TO THE DRAWINGS WITH THE ACTUAL STRUCTURAL I I CONDITIONS THAT EXIST SHALL BE REPORTED TO THE ARCHITECT PRIOR TO SIZE OF TRAPS FOR PLUMBING FIXTURES I COMMENCEMENT WITH SAID WORK. [REFER TO TABLE P3201.1 OF THE RESIDENTIAL CODE OF NY5] KENO. BATH #4 I NEW BATH #2 NEW BATH #3 ( RENO. BATH #5 IZE TRAP 5 �2u ARGHITEGTURAL NOTES PLUMBING FIXTUREIFMINIMUM CCHFQ ° —�—�2„ —�t2„ I —�2„ �-2" (Z2„ rt2nl— 2' r— 2 -- —�— 2 I 1 1/2" 1 1/2"-� 1 1 1/2"-1 1 1/2' 1 1/2"-1 r 1 1/2" I 1 1/2"--j 1 1/2"-� I THE DUTIES OF THE ARCHITECT, HIS EMPLOYEES AND A6ENT5 SHALL TERMINATE WITH AND/OR WHIBATHTUB IRLPOOL TH OR IATTACHMENTS HEAD 1 Y2" 1r-1 1/2" I I 1 1/2" I I I I r 1 1/2" 1 1/2" 1 THE COMPLETION AND DELIVERY OF CONSTRUCTION DOCUMENTS. THE ARCHITECT I I I I.,_ HAS NOT BEEN RETAINED FOR AND I5 NOT RESPONSIBLE FOR CONSTRUCTION BIDET 1 Y4" 1 1 WATER LAV*ORY I I WATER I LAVAITORY LAVAITORY I WATER I I LAV I ORY I WATER PROJECT TITLE: OBSERVATION FOR THIS PROJECT NOR DOES THE ARCHITECT HAVE THE AUTHORITY I I CLOSET I ]CLOSET I I CLOSETI I I CLOSET RENOVATIONS & ALTERATIONS TO THE: TO ACT ON BEHALF OF THE OWNER. ANY DEVIATION FROM THE CONSTRUCTION CLOTHES WASHER STANDPIPE 2„ NEH3" VENT I BATHTUB I I I I I ( I DOCUMENTS SHALL BE PRE-APPROVED IN WRITING BY THE ARCHITECT OF RECORD. DISHWASHER (ON SEPARATE TRAP) I y2' THRU OOF ' i ' I ' 101 I ' M c N E I LL RESIDENCE IT SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO RETAIN A I 1 1/2° 1 SHOWER I 1 1/2" 1 1/2" 1 I �I"�R SHOWER 1 1/2" LICENSED PROFE-5510NAL TO LEGALIZE AND MAINTAIN ANY MODIFICATION TO THE FLOOR DRAIN 2° I I I I I FINISHED SECOND CONSTRUCTION DOCUMENTS WHIGH HAS NOT BEEN PRE-APPROVED BY THE — 2" — 2" —J — 2" 2" ARCHITECT OF RECORD. KITCHEN SINK ONE OR TWO TRAPS, w/ OR „ I 3" I 3" 3" 3„ FLOOR w/o D15HWA5HER 4 FOOD WASTE DISPOSER 1 NEW LAUNDRY I REND. BATH #I 3" I 3" 3" 3° 3�� 710 OLD MENHADEN ROAD 2 THE ARCHITECT SHALL NOT BE RE5PON51BLE FOR THE ACTS OR OMIS51ON5 OF THE LAUNDRY TUB (ONE OR MORE COMPARTMENTS) I )y CUTCHOGUE , NEW YORK 11935 CONTRACTOR OR ANY OTHER SUBCONTRACTOR OR ANY OF THE CONTRACTOR'S OR RENO. KITCHEN SUBCONTRACTOR'S EMPLOYEES OR AGENTS, OR ANY OTHER PERSONS PERFORMING LAVATORY 1 y4" r2" �2„ 1 �2„ I C2" DRAWING TITLE: I ANY OF THE WO1;.K. SHOWER (BASED ON THE TOTAL FLOW RATE r II 1/2" j..1 1/2" T-1 1/2" 1 1/2" AIR ADMITTANCE GENERAL NOTES 3 THE ARCHITECT 15 NOT RESPONSIBLE FOR THE MEANS AND METHODS OF THROUGH 5HOWERHEAD5 4 BODYSPRAY5) I I I I I VALVE CONSTRUCTION NOR FOR SAFETY ON THE JOB SITE, AND THAT THESE FLOW RATE: „ 51 K I I I WATER LAVATORY " 51TTK REQUIRED SIGN POSTING RESPONSIBILITIES ARE INTENDED TO BE AND SHALL REMAIN SOLELY THE 5.-1 GPM AND LE55 CLOSET D W PLUMB I NCG FIXTURE SCHEDULE RESPONSIBILITY OF THE GENERAL CONTRAGTOR. MORE THAN 5.1 GPM UP TO 12.3 GPM 2° i MASHER MORE THAN 12.3 6PM UP TO 25.8 GPM 3° I 1 PLUMBING RISER DIAGRAM 4 BY ACCEPTANCE OF THESE DRAWIIN65, THE OWNER AGREES TO ASSUME FULL MORE THAN 25.8 GPM UP TO 55.6 GPM 4° EXISTING 3" FAI 1 1/2" 2" SHOWER 1 1/2" RESPONSIBILITY FOR ANY DAMAGE OR SETTLEMENT, OR GRAGKIN6 (ETG) OF NEW I I FINISHED FIRST GON5TRUGTION AND WILL NOT HOLD THE ARCHITECT RESPONSIBLE FOR THI5 NOTE —————— ——— � 3, L_— 2" L 3r, 21 FLOOR POSSIBILITY. AS PER NY5 RESIDENTIAL CODE SECTION P3103.2 FR05T CLOSURE. WHERE THE g7.5% 4" C.O. VALUE FOR OUTSIDE DE516N TEMPERATURE 15 O°F OR LESS, VENT EXTENSIONS C w 3„ 3" 3" 3" 3" DRAWN BY: 5DE SHEET NO. 5 ALL SURVEYS, TEST BORINGS, EN6nNEERIN6 REPORTS OR OTHER SIMILAR STUDIES ��� ROOF OR WALL SHALL BE NOT LE55 THAN 3" IN DIA. ANY INCREASE IN THE TO EXIST Q REQUIRED FOR THE PREPARATIONS OF THESE CONSTRUCTION DOCUMENTS AND/OR REQUIRED DURING THE SUBSEQUENT CONSTRUCTION PHASE OF THE PROJECT SHALL 51ZE OF THE VENT SHALL BE MADE NOT LE55 THAN I' IN51DE THE THERMAL ENVELOPE SEPTIC ? CHECKED BY: 5J5 OF THE BUILDING. SYSTEM BE PROVIDED BY THE OWNER DATE: 10.20.25 6 ALL CONTRACTORS THAT HAVE SIGNED CONTRACTS WITH THE OWNER SHALL HAVE NOTE: ®� THE OWNER AND ARCHITECT OF RECORD L15TED AS AN ADDITIONAL INSURED AND AS PER NY5 RESIDENTIAL CODE SECTION P3103.1.1 ROOF EXTENSION. OPEN VENT PIPES BASEMENT 00 SHALL CARRY POSITIVE STATEMENT THAT THE SPECIFIC COVERA6E REQUIRED ARE THAT EXTEND THROUGH A ROOF SHALL BE TERMINATED NOT LE55 THAN 6" ABOVE THE NOTE: (2) H05E BIBS ARE TO BE INSTALLED ON THE EXTERIOR OF HOUSE FLOOR SCALE: AS NOTED PROVIDED. HE SHALL HOLD HARMLESS THE ARCHITECT AND OWNER AGAINST ANY ROOF OR b" ABOVE THE ANTICIPATED SNOW ACCUMULATION, WHIGHEVER 15 GREATER. 2 FLUMBIN6 RIBER 1:) IA&RAM AND ALL CLAIMS ARISING FROM WIORK PERFORMED BY HIS EMPLOYEES AND ANY NOTE: PROJECT N0. 2515 SUBCONTRACTOR AND HIS EMPLOYEES BY ACCEPTANCE OF THESE DOCUMENTS. AIOO N.T.5. PLUMBER TO EVALUATE EXISTING DOMESTIC HOT WATER CAPACITY AND PIPING SUPPLY SIZES AND INCREASE SAME AS REQ'D. 1*;)EMOL 171 ON. MOTES THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY 1 LINE OF WALLS, DOORS, WINDOWS, ETC. TO BE REMOVED; PROVIDE ALL TEMPORARY SHORING THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE,AND ARE AND SHALL AS REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE REQUIRED (TYPJ INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER LINE OF DOORS, WINDOWS, ETC. TO BE REMOVED;STORE SECURELY ON SITE FOR RELOCATION LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE 2 (COORDINATE STORAGE W/ OWNER) ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. DREMOVE EXIST. CABINETS, AND APPLIANCES IN THEIR ENTIRETY, REFRIGERATOR AND DISHWASHER IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION TO BE STORED SECURELY ON SITE FOR REUSE (GOORDINATE STORAGE r1/ OWNER) OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I O REMOVE EXIST. SINK GAP LINES AS REQUIRED;STORE SINK AND FAUCET ON 51TE FOR POSSIBLE ANY WAY, IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION'ALTERED BY' REUSE (GOORDINATE STORAGE w/ OWNER) FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE S SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION REMOVE EXIST. PLUMBING FIXTURES IN THEIR ENTIRETY;GAP LINES AS REQUIRED LAW ARTICLE 147-ARCHITECTURE,SECTION 7307) 6 REMOVE EXIST. TILE FLOORING; PATCH AND REPAIR AS REQ'D. TO PREP FOR NEW FLOORING; ISSUANCE: COORDINATE W CONSTRUCTION PLAN OEXISTING ROOF TO BE REMOVED FROM THI5 POINT BACK FOR ADDITIONS; COORDINATE EXTENT NO. DATE: DESCRIPTION: WITH CONSTRUCTION PLAN 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING DNEPq EXISTING WASHER AND DRYER TO BE REMOVED; STORE SECURELY ON SITE FOR RELOCATION TO LAUNDRY ROOM; CUT AND GAP LINE-5 AS REQ'D. ® 04.09.26 ADD BASEMENT EGRESS STAIR EXIST. O9 LINE OF ROOF ABOVE TO REMAIN SHOWN DOTTED (TYP) DECK -40-EL, (-)I'-3 112" 10 EXIST. HOSE BIB TO BE REMOVED; GUT AND GAP LINES AS REQ'D. 11 EXIST. REF. TO BE REMOVED; STORE 5ECURELY ON SITE FOR RELOCATION TO NEW GARAGE EXIST. PATIO 12 EXIST. DEEP FREEZER TO BE REMOVED; STORE SECURELY ON 51TE FOR RELOCATION TO NEW a -40-EL. (-)I'-6 5/4" GARAGE 13 EXIST. POT HANGING RACK TO BE REMOVED; PATCH AND REPAIR CEILING AS REO'D. DN. 14 REMOVE GARAGE SLAB AS REQ'D. FOR NEW GARAGE SLAB PITCH. I I I 1 1 2 1 I II I I I I DN' I II a i I 1 EXIST. I a J EXIST. ----jI EXIST. DEN PORCH IIKITCHEN 2 illirF=��ll I!�IfIL— 11Ur— II I II I I IIII � II I I IIII \ -I �I 3 I I 15 IIII 1 /rill I -------- ------- -- I II I I I I � LJ 1 u I 5 / t--,jk 0 1 STRUCTURAL KUROS SORBI-AVA ENGINEERING \\ I 111 ENGINEER: 169 COM MACK ROAD SUITE H-362 EXIST. COMMACK, NY 11725 I L----- --_ DINING ROOM 631-355-5556 I � I II I �__�r====11 I =�� I i �. �----i 5 I I I I I IIII T" __ I I I II I I 12 I I I I b 5 ot I I L--J L----J� XIS\�� I I 8 LAUNDRY II 1 IIIIIIIIIIIf II II IjI Il II jI I II II ��� Il1 EXITH 5 Y.;tI BA C 10 EXIST. , IL----- .. I IIII I I r -- -- EXIST. I I GLO5• I III I I --- --- DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. ------------------------------------ I I 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 P. 631.271.5400 WWW.DDANY.NET EXISTING LIVING ROOM I EXIST. ICopyright 02025 All Rights Reserved.I GARAGE --- --- I --- --- FOYER SEAL: PROJECT NORTH: I I I I II I I—----------------I I I r � I PROJECT TITLE: PORCH \ I RENOVATIONS & ALTERATIONS TO THE: I L. (-) O-7 I/2 � \ i NOTE: _ _______ GENERAL CONTRACTOR TO COORDINATE 4 SUPERVISE VV OWNER RETAINED MOVIING T -___----- a \ I COMPANY TO REMOVE d STORE OWNER FURNISHINGS. GENERAL CONTRACTOR TO M c N E I LL RESIDENCE COORDINATE 4 SUPERVISE RETURN OF OWNER FURNISHING AT COMPLETION OF I �,'" � ❑a a Fol ��\❑O ' CONSTRUCTION. =�/ ------------------------ I - - - — - - - - - - - - - - - - - - - - - - - - - - - - - - -�I 710 OLD MENHADEN ROAD WALL LEGEND CUTCHOGUE , NEW YORK 11935 a .T.S. DRAWING TITLE: RU6TION TO BE 5URFAGE5 ADJACENT TO DEMO NI REMOVED.ATERIALS TTO MIATCH FIRST FLOOR AND ALIGN FLUSH WITH EXISTING. DEMOLITION PLAN NEW WALL CONSTRUCTION: INTERIOR WALLS: U.O.N. NOTES AND DETAILS Y2" GYPSUM WALL BOARD OVER 2"x4" WOOD 5TUD5 ® lb"o.c. EXTERIOR WALLS: U.O.N. 'HYDROCGAP' HOUSE WRAP AS MANUF. BY BENJAMIN OBDYKE OVER YY GDX PLYWOOD OVER 2"xb" WOOD STUDS ® 16" ox— W/ 5" R-21 BATT INSULATION AND Y2" GYPSUM WALL BOARD. DRAWN BY: 50E SHEET NO. NEW FOUNDATION WALL CHECKED BY: 5_I5 EXISTING WALL GON5TRUGTION TO REMAIN DATE: 10.20.25 -101 f= 1R!5T f"LOOR ::)EMOLITION FLAN NOTE: SCALE: A5 NOTED ALL GYPSUM WALL5 AND CEILINGS ARE TO BE TAPED AND SPAGKLIED (THREE AIUI I/4" = I'-0° GOAT5) AND PAINTED WITH ONE COAT PRIMER AND TWO GOATS FINISHED COLOR PROJECT NO. 2515 REFER TO DEMOLITION NOTES FOR ADDITIONAL REOUIREMENT5 AS SELECTED BY OWNER PROVIDE WATER RE-515TANT GYPSUM WALL BOARD IN ALL DAMP/ NET LOGATION5. I a I 1;)EMOLITION MOTES THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY OLINE OF WALL5, DOORS, WINDOWS, ETC. TO BE REMOVED; PROVIDE ALL TEMPORARY THE ARCHITECT ARE INSTRUMENTS THE ARCHITECT'S SERVICE,AND ARE AND SHALL 1 REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE SHORING A5 REQUIRED (TYPJ INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE 2 EXIST. WINDOW TO BE REMOVED; STORE ON 51TE FOR RELOCATION ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. OREMOVE EXI5T. PLUMBING FIXTURES IN THEIR ENTIRETY;GAP LINES A5 REQUIRED IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I 4 REMOVE EXIST. TILE FLOORING ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING; PATCH AND REPAIR A5 REQ'D. TO PREP FOR NEW FLOORING ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION'ALTERED BY' FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE O EX15T. PULL DOWN ATTIC ACCESS TO BE REMOVED; STORE ON 51TE FOR RELOCATION SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION LAW ARTICLE 147-ARCHITECTURE,SECTION 7307) 6 LINE OF ROOF ABOVE TO REMAIN SHOWN DOTTED (TYP) ISSUANCE: I O OEXI5TIN6 ROOF TO BE REMOVED FROM HERE BACK FOR ADDITIONS; COORDINATE NO. DATE: DESCRIPTION: EXTENT WITH CON5TRUGTION PLAN 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING 8 REMOVE EXISTING DECKING MATERIAL TO BE REPLACED; GUARD RAIL TO BE REMOVED REVISED PER OWNER CHANGES AND-5TORED ON 51TE FOR RE—INSTALLATION ® 04.09.26 ADD BASEMENT EGRESS STAIR NOT U5ED 9 1 l I _ r — — — — — — — — — — 6 — — — — — — — — — — — - I I - I - - - - - -I - - - - - - - - - - - - - - - - - r � I 1 1 --- -______= I 3 I II 3 XIST j I PRIMARY BATH II I I WALK IN GLO5. I I BALCONY (BATH #2) I EX ST I I i r----� L————— EXIST. I I 4 II 5 I I BEDROOM #3 ii ( —�I 1 g II 1 I IIII I I li 01i I II I LJ II I IIII - - - - - - 1- - 4 EX1 1 I � I I 1 L 1 -------- I I 1 L u I � \LL STRUCTURAL KUROS SORBI-AVA ENGINEERING ENGINEER: 169 COMMACK ROAD SUITE H-362 - - 3 3 I \ I 1 COMMACK, NY 11725 - - - - - - - -� - - - - - I \ EXIST - - - - - 631-355-5556 11 I I I PRIMARY BEDROOM 1 I (BE ROOM #I) I III; L_J J I l(ul) I I I ( ► \ 3 1 EXIST, HALL 4AX #3- �EL. q'-II I/8° j I I j EXIST. 11 _ I EXIST. I EXIST. \ I GLO5• ( ❑ nEl CLO5. - - - - - - - - - - - - - - - - - - - - ki 1 III / I 6 r 3 'j. ,. I 1 III---- -- ILL �/ I �n; DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. I I 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 I 2 -- -- I I EXIST. P. 631.271 .5400 WWW.DDANY.NET Copyright ©2025 All Rights Reserved. __ i BEDROOM #2 I I SEAL: PROJECT NORTH: E�,IST. II I - 1 1I I I 11 LI- - - - - - - - - - - - - - - - - � I - - - - - - - - - - - - -I I i PROJECT TITLE: RENOVATIONS & ALTERATIONS TO THE: I � II II McNEILL RESIDENCE LL- _ __ - - _____=-J� 710 OLD MENHADEN ROAD NALL LEGEND CUTCHOGUE , NEW YORK 11935 N.T.S. DRAWING TITLE: SURFAGES ADDJJA ENT TO DEMO WTIN TO BE �MATERiAL5�TO MIHAT L 5EGOND FLOOR AND ALIGN FLU5H WITH EXISTING. DEMOLITION PLAN NEW WALL CON5TRUGTION: NOTE5 AND DETAIL5 INTERIOR WALL5: U.O.N. Y2" GYPSUM WALL BOARD OVER 2"x4" WOOD STUDS ® I6"o.c. EXTERIOR WALL5: U.O.N. 'HYDR06AP' HOUSE WRAP AS MANUF. BY BENJAMIN OBDYKE OVER YY GDX PLYWOOD OVER 2"x6" WOOD 5TUD5 ® 16" o.c. W/ 512" R-21 BATT IN5ULATION AND Y2" 6YP5UM WALL BOARD.. DRAWN BY: 5DE SHEET NO. NEW FOUNDATION WALL CHECKED BY: EXISTING WALL GON5TRU6TION TO REMAIN DATE: 10.20.25 Aml SECC`N� �LCCR �EMCL1710N FLAN NOTE: SCALE: A5 NOTED ALL GYPSUM WALL5 AND CEILINGS ARE TO BE TAPED AND 5PAGKLED (THREE AI02 1/4" = I'-0" COAT5) AND PAINTED WITH ONE GOAT PRIMER AND TWO COAT5 FIN15HED COLOR PROJECT N0. 2515 A5 SELECTED BY OWNER. PROVIDE WATER RE515TANT GYPSUM WALL BOARD IN REFER TO DEMOLITION NOTE5 FOR ADDITIONAL REQUIREMENTS ALL DAMP/ WET LOGATION5. I I � CONSTRUCT I ON NOTES ° NEW VY 56H. 40 5TL. POST FROM THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY ABOVE THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE,AND ARE AND SHALL LINE OF EXIST. FDN. WALL TO BE REMOVED/ CHOPPED TO BE BELOW NEW SLAB REMAIN THE PROPERTY Of THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE (D INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE 5" WIDE POURED CONCRETE FOUNDATION WALL v41 #4 CONTINUOUS HORIZONTAL BAR WITHIN 6" OF TOP OF 5 Y4"xbmx YY STEEL BA5EPLATE ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL O WALL W 30" OVERLAPPING @ SPLICE POINT54 #4 VERTICAL BARS @ 45" O.C. Pq/ 6" EMBEDMENT INTO COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. FOOTING. H/12"x24" CONTINUOUS FOOTING TO BE 3'-0" BELOW GRADE MINIMUM Pq/ (2) #5 REBAR5 GALv. ANCHOR BOLTS @ 48" O.C. SEAM SEAL, COPPER FLASHING BETWEEN FOUNDATION 4 PREDRILLED HOLES OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I ,—(4) V DIA. LAG 5GREN5 INTO IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION c.oNTiNuou5; !Y,5,, N (1) 2x6 AGO. SILL PLATE 4 (1) D. FIR 2x6 SILL PLATE; TUFF 4 DRY WATER PROOFING ON NEW FND. WALL; ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING TOP OF WALL TO ALIGN kq/ EXIST. ADJACENT, PROVIDE (R-10) RIGID IN5UL. ON IN51DE OF FND. WALL ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION'ALTERED BY" ----------------------------------------------T--------------------------------------------------- WIDE POURED CONCRETE FOUNDATION WALL W (1) #4 VERTICAL BAR a -72" O.G. EXTENDED INTO FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE I V SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION FOOTING, (1) WITHIN &N OF CORNERS AND OPENINGS, (1) #4 HORIZONTAL REBAR AT TOP Pq1 3" COVER Pq/ EXISTING L.V.L. GIRDER TO REMAIN LAW ARTICLE 147-ARCHITECTURE,SECTION 7307) 12"x24" CONTINUOUS FOOTING TO BE 3'-0" BELOW GRADE Pi/ (2) #5 REBAR5 CONTINUOUS; 5/5" 6ALV. ANCHOR BOLTS @ 230 O.G. SEAM SEAL, COPPER FLASHING BETWEEN FOUNDATION 4 (1) 2x4 AGO. SILL ISSUANCE: PLATE 4 (1) D. FIR 2x4 SILL PLATE NO. DATE: DESCRIPTION: OPROVIDE #5 DOWELS @ 12" O.C.-VERTICALLY. DRILL4 EPDXY GROUT 6" INTO EXISTING FOUNDATION WALL 4 (2) #5 DOWELS INTO EXISTING FOOTING. A EXTERIOR 51DE5130TH PLATES 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING OPROVIDE 2" THICK POURED CONCRETE VERMIN SLAB OVER 6 MIL POLYETHYLENE VAPOR RETARDER, luxallx) 04.09.26 =11)PER OWNER CHANUES JOINTS LAPPED b" MIN., OVER 4" COMPACTED COURSE GRAVEL; MAINTAIN MIN. 3'-0" UNDER FLOOR SPACE -Vx8"xV2" STEEL CAP PLATE ADD BASEMENT EGRESS STAIR OPROVIDE STEP FOOTING AT 2'-0" MAX. HORIZONTAL AND V-O" MAX. VERTICAL 3/au DIA. LAG SCREWS INTO PROVIDE MIN. 4" P.C. SLAB W 6 MIL V.B. W bxb'o,(o NM OVER 6" COMPACTED POROUS FILL PREDRILLED HOLES COMPACTED TO c15% DENSITY H/YY EXPANSION JOINT @ PERIMETER WHERE SLAB MEETS FND. WALLS SEE GONG. 4 FND. NOTES FOR ADDITIONAL REGUIREMENT5; PITCH SLAB TO GARAGE DOORVe," PER FOOT. NEW 3Y2" 5GH. 40 (OD. 4") 5TL. SLAB TO MATCH AND ALIGN W EXIST. GARAGE SLAB; DOWEL INTO EXIST. SLAB P05T OPROVIDE 16'x8" CRAWL SPACE VENT H/ INSECT SCREEN; PROVIDE (2) BOX BEAM OVER OPENING; VENT TO BE LOCATED WITHIN 56" OF CORNER AND BE INSTALLED WITHOUT OE35TRUGTION 5AV4 CUT FDN. AS REQ'D. TO PROVIDE 24"Ab" MIN. OPENING; PROVIDE (2) BOX BEAM OVER OPENING 4 INSULATED ACCESS PANEL ON FULL BASEMENT SIDE - - - - - - - - - - - - - ATTACH SIMP50N' (HTT22) HOLD DOWN TO CORNER POST IMBED IN FND. WALL wl SIMP50N' (S5TQ) BOLT (5EE 4 ON A-400 FOR DETAILS) ATTACH SIMP50N' (HTT22) HOLD DOWN TO KING P05T IMBED IN FND. HALL W SIMPSON' 2 F (55T5) BOLT (SEE 4 ON A-400 FOR DETAILS) SEE FIRST FLOOR PLAN FOR LOCATION 1=057 CAP r;)E7AIL 15 F--------------- A103 1 1/2" 11-011 A-500 i - _ _ J I I - - — - - - - - - - - - - - - - i SHOWN OF STAIR/ DECK ABOVE 5HO DOTTED (TYP) R� 7 it 1 13 LINE OF CRIPPLE WALL ABOVE (SHOWN DOTTED) TO BE 2"x4" WOOD STUDS @ 16"oc. Pq/ (1) 2x4 AGO. SILL F - - - - - - - - - - - - - -- L A ( PLATE 4 (1) D. FIR 2x4 SILL PLATE SECURED TO EXIST. SLAB Pq/ P.A.F. PROVIDE COPPER TERMITE SHIELD -4 file > 1 _j 11 G) PROVIDE MIN. R-30 BATT IN5UL. IN F.J. BAYS F 2611" 4'-0" A D POST FROM ABOVE TO BEAR 50LIDLY ON FDN. WALL 25 EXISTING FULL BASEMENT P05T FROM ABOVE TO BEAR 50LIDLY ON GIRDER (SHOWN DOTTED) 7. 7. F - I I ; , - , (UNFINISHED) L L _' / it 1 12 STEEL COLUMN FROM ABOVE TO BEAR 50LIDLY ON FDN. WALL; PROVIDE Wx Wx 5/4' STEEL BASE PLATE; F TF T V I ► CDIF PLATE WILL 13E OVER BEAM POCKET NOTIFY ARCHITECT V-10 1 2' (+/- 2q Lu T 0 x EXIST. 5TL. GOL 4 FOOTING TO REMAIN (TYP. U.O.N) -1 UP Lu 21-011 .21-0 IT) 15-2 172,1+T- -!!� F EXIST. 5TL. COL TO REMAIN, FOOTING TO BE REMOVED (SEE NOTE #20 FOR NEW FOOTING); PROVIDE TEMP CD SHORING AS REO!D. ��:;C2 bD7 F -1 L - - - - - - FEX I ST.,(3) 1 3/4"AII'Yj5" L. 1:1. NEW 3Y2" 5GH. 40 (O.D. 4") 5TL. POST UNDER P05T/ GIRDER A13OVE TO BEAR 50LIDLY ON 4b"x4b"xI2" DEEP r b L Ilb FOOTING Pq/ #5 BARS EA WAY TO BEAR ON UNDISTURBED SOIL; PROVIDE GAP 4 BASE PLATE FOR FULL _T BEARING (INCLUDING EXIST. ADJACENT COL. TO REMAIN); WELD TO BE Y4" FILLET WELD. GAP PLATE LAG CRAWL SPACE 4 L__ A BOLTS TO BE %" IN PREDRILLED HOLES; %" ANCHOR BOLTS FOR BASE PLATE H/ I" EDGE DISTANCE. b 0 Z I )_� 20 REPAIR P. GONG. SLAB AS REO'D. SEE DETAIL TH15 SHEET FOR POST CAP Lc I ]EXIST. Lc (3 STL. COLUMN FROM ABOVE TO BEAR 50LIDLY ON GIRDER (5HONN DOTTED). PROVIDE 5 Y4"(MIN)x8"xY2" 5TL. STRUCTURAL KUROS SORBI-AVA ENGINEERING x:R �� ELEG. 21 5 14 23 IPANEL BASE PLATE FOR FULL BEARING; ATTACH Pi/ (4) 3/8" VIA. LAG 5GREN5 INTO PREDRILLED HOLES ENGINEER: 169 COMMACK ROAD U- INSTALL SIMP50N' HIOA TIE ON F.J. WITHIN 2'-0" EA. 51DE OF NEW 5TL. COL. FROM ABOVE TO GONNECT TO SUITE H-362 JL - - - - - - - - - - - - - - I :2D GIRDER COMMACK, NY 11725 631-355-5556 :5 1 PROVIDE -9/4" T46 PLY NO. Pql GLUE/NAIL vq/ PACK UP AS REO'D. FOR NEW FINISHED FLOOR TO ALIGN W F EXIST. ADJACENT (TYP) ALTERNATIVELY- I 314"xqY2" L.V.L. OR q Y2" TJI F.J. MAY BE USED TO AVOID PACK UP 2A PROVIDE MIN. Ibx24 ACCESS TO BELOW FLOOR SPACE. COORDINATE LOCATION IN FIELD 00" OIL TANK 4^�2AO F.J. �I lu x EXIST. 16 REMOVE EXIST. WINDOW 4 SAW CUT EXISTING FOUNDATION AS REO'D. FOR NEW OWNER SELECTED 3'-0" n. 2�5 I @ O.G. 15 EXIST. 18 EXTERIOR GRAVE DOOR; PROVIDE (2) BOX BM. OVER OPENING 4 2X6 AGO. WRAPPED FRAME FOR INSTALL GRADE AND ALIGN -4 HVAG EXIST. 16 CHOP PREVIOUSLY INSTALLED FOOTING AS REO'D. 4 PROVIDE UNDERPINNING ALONG REAR NALL OF OIL TANK F_ L 6 1 G) ADDITION TO EXTEND FOUNDATION FOOTING AS REO'D. TO BE 3'-0" MIN. BELOW GRADE NEW E T. (%3 5/4-A I -/7a" LAf.L EGRESS STAIR FOOTING; INSTALL 12" THICK BY 24" WIDE FOOTING (TYP. SEE DETAIL ON THIS SHEET) LL_ 8" WIDE POURED CONCRETE FOUNDATION :2:!7 EX15TIN6 _j I r I WALL N/ #5 VERTICAL REBAR5 @ E3611 O.G. 3" FROM EN05 4 EMBEDDED IN FOOTING. PROVIDE MIN. (2) #5 SLAB ON GRADE _j KEBABS @ TOP 4 BOTTOM OF WALL 0" MIN. CLEAR) W12X24" CONTINUOUS FOOTING (TO BEAR ON VIRGIN -- 50 F SOIL) Vil (3) #5 REBAR5 CONTINUOUS U 2AO F.J. I C L---- @ 16, O.G. PROVIDE NEW P. GONG. STAIRS Pq/ EXTERIOR GRADE HANDRAIL TO COMPLY WITH NY5 RESIDENTIAL CODE L L _J -I IS PROVIDE CATCH BASIN PIPED TO DRYNELL; 5EE DRYNELL CALCULATION ON A-001 1 1 14 23 24 1 1 ------11 Lc I 15 13 EXIST. F EXISTING DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. LAB FULL BASEMENT L----J (UNFINISHED) 1 L I 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 — — — — — — - — — — — — — — P. 6 31.2 71.5 4 0 0 WWW.DDANY.NET ————— 1 I i Copyright 0 2025 All Rights Reserved. x 4 15 1-------4 Lu SEAL: PROJECT NORTH: NEP4 SLAB un 0 I- - - - - - - - -V - - - - - - - - - - - - - - - - - - - - - - - - -7 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - L I 1 1 i 1 1 PROJECT TITLE: SLAB ON GRADE D INSTALL SMOKE DETECTOR AND CARBON RENOVATIONS & ALTERATIONS TO THE: MONOXIDE DETECTORS IN A0GORDANGE WITH ALL C1L`- - - - - - - - - - - - - - - --ill STATE AND LOGAL CODE REQUIREMENTS. SINGLE McNEILL RESIDENCE Ir -- ------------- A-A AND MULTIPLE STATION SMOKE ALARMS AS PER < IF - - - - - - - - A-I A-18013.1, WIRED IN SERIES THE RESIDENTIAL CODE OF NY5 R-514, R-315 AND 12 F -1 F -1 F -I -1 L -1 4'4'-0" 710 OLD MENHADEN ROAD L L L -1 ------------------------- ------------------------------------------------ --------- TYP. NALL LEGEND CUTCHOGUE NEW YORK 11935 15 DRAWING TITLE: GUT OFF EXISTING NALL5/rON5TRUrTION TO BE REMOVED. PATCH/REPAIR ALL PROJECTION 5URFAGES ADJACENT TO WITH MATERIALS TO MATCH FOUNDATION PLAN AND ALIGN FLUSH WITH EXISTING. NOTES AND DETAILS L 10 10 3* NON-SHRINK UNDERFINNIN(O PLAN GROUT NEW WALL CONSTRUCTION: UNDERFINNIN& DETAIL NOT T05GALE 'GETCO' VOLGLAY NATER5TOP-RX 101 INTERIOR WALLS: U.O.N. - -- ---- ---- ---- #4 DONEL5 4" MIN. EXISTING FOOTING CONCRETE JOINT YY GYPSUM WALL BOARD OVER 2"x4o WOOD STUDS @ 16"o.c. 11-1011 11-1011�b EMBEDMa4T NATER5TOP EXTERIOR NALL5: U.O.N. 14'-4" (+/- V.I.FJ I I I 'HYDR06AP' HOUSE WRAP AS MANUF. BY BENJAMIN OBDYKE KX 7 #4 DOWELS 4" MIN. OVER YY CDX PLYWOOD OVER 2"xb" WOOD STUDS @ 16" o.c. EMBEDMENT PV %" R-21 BATT INSULATION ANDV2" GYPSUM HALL BOARD. NOTE: DRAWN BY: 50E SHEET NO. ALL DIMEN51ON TAKEN TO GONG. POUR UNDERPINNING CONGRETE > NEW FOUNDATION WALL CHECKED BY: 5J5 FLASHING NOTE PROVIDE YORK5HIELD' 106T5 COPPER FLASHING WHERE HOOD MEETS MASONRY (TIrp) EXISTING WALL GONST'RUCTION TO REMAIN DATE: 10.20.25 P O U N1::)A T I O N FLAN NOTE: TEMPORARY SHEETING NOTE-• SCALE: A5 NOTED Aml 03 PROVIDE 'CETCOWOLGLAY NATER,5TOP-RX 101 CONCRETE JOINT NATER5TOP ALL GYPSUM NALL5 AND CEILINGS ARE TO BE TAPED AND 5PACKLED (THREE A103 1/4" = II__OII VERTICALLY WHERE NEW CONCRETE POUR JOINS EXISTING POURED CONCRETE. UNDERFINNIN6 ELEVATION A-A SECTION A-A GOAT5) AND PAINTED WITH ONE COAT PRIMER AND TWO GOATS FINISHED COLOR PROJECT No. 2515 INSTALL AS PER MANUFACTURES SPECIFICATIONS. PROVIDE WATERPROOF MEMBRANE NOT TO SCALE A-I NOT TO 5GALE AS SELECTED BY OWNER. PROVIDE WATER RESISTANT GYPSUM WALL BOARD IN P-O" TO EACH SIDE WHERE NEW CONCRETE JOINS EXIST. POURED CONCRETE ALL DAMP/ NET LOGATION5. .......... ......... ... CON57RUC71 ON N07r=5 L I &H7/\/EN7 CALCULA71ONS E :w A; x Aa a 71 THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY NEW DEN REQUIRED LIGHT TRANSMITTING AREA = THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE,AND ARE AND SHALL i PROVIDE 5/8" GYP. BD. ON WALL5 AND CEILING OF GARAGE (TYP) REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE AREA = 2025 SQ.FT. 202.5 50.FT. X b% = 16.2 50.FT O _ / INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO RE USED IN OTHER LINE OF FND. WALL BELOW PROPOSED WINDOW LI6HT TRANSMITTING AREA=36.2 SQ.FT. V LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL REQUIRED AIR VENTILATION AREA = COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. O LINE OF WALL ABOVE SHOWN DOTTED 202.5 50.FT• X 4% = 8•I SQ.FT. IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION PROPOSED WINDOW AIR VENTILATION = 15.3 5Q.FT. ✓ OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING 4 LINE OF ROOF ABOVE SHOWN DOTTED (TYPJ NEW LAUNDRY REQUIRED LIGHT TRANSMITTING AREA = ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION'ALTERED BY" FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE AREA = 71.7 SQ.FT. 71.7 SQ.FT. X 85i5 = 5.7 SQ.FT SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION 5 RELOCATED GARAGE DOOR PROPOSED WINDOW L16HT TRANSMITTING AREA=5.74 50.FT. LAW ARTICLE 147-ARCHITECTURE,SECTION 7307) CD INSTALL WINDOW UNIT RELOCATED FROM EXIST. GARAGE REQUIRED AIR VENTILATION AREA = ISSUANCE: 71.7 50.FT. X 4% = 2A 50.FT• CDPROVIDE 5TEP5 TO HAVE AGO. STRINGER, FINISH TREADS w/ OAK OR APPROVED EQUAL TO PROPOSED WINDOW AIR VENTILATION = 32 50.FT. ✓ NO. DATE: DESCRIPTION: COMPLY W/ NY5 RESIDENTIAL CODE 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING 1 8 NOT USED RENO. KITCHEN/ REQUIRED LIGHT TRA 5MIT 5Q FT. XX 895 = 35.0 SQ.FT ® 04.09.26 EAT IN AREA ADD BASEMENT EGRESS STAIR EXIST. 9 OWNER SELECTED EXTERIOR GRADE HANDRAIL/ GUARDRAIL AND POSTS TO COMPLY W/ AREA= 4365A 50.FT. PROPOSED WINOOW/DOOR LIGHT TRANSMITTING AREA=82.g 50.FT. DECK THE RESIDENTIAL CODE OF NYS; 50 A 4" SPHERE CAN NOT PASS THROUGH (TYP 41-EL. (-)I'-3 1/2" REQUIRED AIR VENTILATION AREA = 10 INSTALL OWNER SELECTED 5TORA6E SHELVING; PROVIDE BLOCKING AS REQ'D. 436A 50.FT. X 4% = 1-1.5 50.FT. PROPOSED WINDOW4 DOOR AIR VENTILATION = 40.0 50.FT. 11 PATCH 8 REPAIR WALL TO MATCH 4 ALIGN w/ EXIST. ADJACENT EXIST. NEW HOME OFFICE REQUIRED LIGHT TRANSMITTING AREA = PATIO 12 FURR OUT WALL AS REQ'D. TO ALIGN w/ NEW 2xb WALL FRAMING; PROVIDE AREA = 82A 50.FT. 82A 50.FT. X 8% = 6.6 50.FT / EL. (-)1'-6 3/4" R-21 BATT IN50L. IN STUD BAYS PROPOSED WINDOW LIGHT TRANSMITTING AREA=21.0 50.FT. V 4 CD51ELEOTED PROVIDE AND INSTALL NEW WOOD FLOORINGTO MATCH EXISTING; FINISH w/ OWNER WATER BASED FINISHES REQUIRED AIR VENTILATION AREA = - 82.q 50.FT. X 4% = 3.3 5Q.FT. DN. 14 RE-INSTALL DRYER,VENT TO OUT5IDE PER NY5 RESIDENTIAL CODE PROPOSED WINDOW AIR VENTILATION = q.0 50.FT. ✓ '-6" I'-?" 1/2" 7'-g 5/8"+/- 1S RE-INSTALL WASHING MACHINE TIE INTO EXIST. WASTE LINE (V.IP) 31 LTIPU II 41k, PROVIDE AND INSTALL OWNER SELECTED STORAGE ABOVEw/ DRYINGRACK; G TW2 II 32 16 2G PROVIDE BLOGKING AS REQ'D. A-500 +1 --�-i DN. 17 PROVIDE AND INSTALL OWNER SELECTED TILE FLOORING 28 2'b"xb'8' I GD I 1g PROVIDE EXHAUST FAN VENTED TO EXTERIOR ELECTRICAL NOTE: PROVIDE ALL ELECTRICAL OUTLETS, 5WITCHE5, ETC. 0. PATCH AND REPAIR WOOD FLOORING AS REQ'D. (TYP. OF AREA OF WORK, EXCLUDING AG( ORDIN(5 TO ALL STATE AND LOCAL GODES. 1 q i I 19 BATHROOMS) GOORDINATE WITH OWNER, LOCATIONS OF ALL ADDITIONAL 23 ----i SWITCHING, OUTLETS AND LIGHTING. O i i 1 H NEW EXIST. I 20 REMOVE EXIST. SIDING 4 SHEATHING; GAT ® MID-SPAN PROVIDE Y2" GYP. BD. 25 I I EAT-IN HOME OFFICE PORCH I I- PROVIDE ELECTRICAL CONVENIENCE RECEPTACLE 13'-10 I/2" (+/- Y.I.Fa II I ; I (NO SLEEPING) I DOWNER SELECTED FOLDING TABLE w/ STORAGE CABINET 4 SINK (5EE PLUMBING OUTLETS PER E3g01 2-N AREA FIXTURE SCHEDULE) 6 1/ " 13'-4" +/- I 34 I OER SELECTED 2'-6" FIRE RATED DOOR d ASSEMBLY w/ SELF CLOSING HARDWARE TO 2- PROVIDE CONVENIENCE RECEPTACLE OUTLET IN 5'-11 1/2" 4 I/2" 7'-0° -' I 26 ; I 22 WNBE 20 MINUTE RATED; DOOR STYLE TO MATCH EXISTING DOOR STYLE 4 PROFILES GARAGE, PER E3gOl.g WITH GFGI, PER E3g022 I i------i Iq 23 RELOCATED KITCHEN WINDOW TO BE GENTEREDON SINK; COORDINATE w/ KITCHEN 3- PROVIDE ONE WALL SWITGH CONTROLLED LIGHTING ON I I DESIGNER THE EXTERIOR SIDE OF EACH OUTDOOR E(5RE55 DOOR 2 0 i i HAVING GRADE LEVEL ACCESS IN ACCORDANCE WITH Q. o Q I r--, 24 RE-INSTALL REFRIGERATOR E3g03 3 Ib I'I i I i i 5T0. i i RENOVATED _ 4- GFGI'5 ARE TO BE PROVIDED, PER E3g02 25 OWNER SELECTED MILLWORK COORDINATE w/ KITCHEN DESIGNER ^1 - G - KITCHEN Iq Lu " �J�EGG �J�EGG �� --� Iq OWNER SELECTED 36" INDUCTION RANGE w/ OWNER SELECTED RANGE HOOD PIPED \ `9 /� �-//! x 26 TO EXTERIOR PER NY5 RESIDENTIAL CODE. STRUCTURAL KUROS SORBI-AVA ENGINEERING � ml 15 14 25 2q � PLUMBING NOTE: u) NEW AUNDRY 17 I- m d I- MATERIALS FOR WATER SUPPLY AND DISTRIBUTION ENGINEER: 169 COMMACK ROAD O IS 20 cv m +bco Lu 27 OWNER SELECTED 3'-4"xq'-4" 15LAND COORDINATE w/ KITCHEN DESIGNER SYSTEMS, PER TABLES P2g06.4., P2g06.5, P2g0b.6 SUITE H-362 ------ -- ------- gyp° N COMMACK, NY 11725 - - 33 O24 ___------__I_____I �' ,� ENO 28 RE-INSTALL DISHWASHER 2- MATERIALS FOR DRAINS, WASTE AND VENTS PER 631-355-5556 i i 4'-0" 4 1/2° DINING ROOM TABLES P3002.1 AND P3111.3 12 II 25 OWNER'S 29 OWNER SELECTED WINE/ BEVERAGE FRIDGE r •II CLOSET WINDOW/ DOOR NOTE: w1 - ii O GD INSTALL OWNER SELECTED STORAGESHELVING; PROVIDE LOOK ON DOOR TO BE ALL NEW WINDOWS TO BE MANUFACTURED BY "ANDER5EN",. --� 2KEYED TO OWNER KEY MODEL NUMBER AS INDICATED ON PLANS. ALL NEW WINDOWS O Ca SD ® 31 PROVIDE AND INSTALL NEW OWNER SELECTED SCREEN DOOR ASSEMBLY TO COMPLY WITH THE RESIDENTIAL CODE OF NEW PORK x Yet,yz STATE. TO BE 400 SERIES WITH /8" PERMANENT INTERIOR d 17 IS 5TOR. EXTERIOR 6RILLE5• FDL SPACER BAR;LOW-E 6LA55 AND II N __, . INSTALL WINDOW UNIT RELOCATED FROM EXIST. DEN; PROVIDE NEW TEMPERED m NEW DEN - IF BINS 32 GLASS SASHES MULL KIT; TO BE MULLED w/ EXIST. WINDOW TO REMAIN INSECT SCREENS. HARDWARE A5 SELECTED BY OWNER, (T) =' ik AFTER MODEL # INDICATES TEMPERED GLA55 UNIT PROVIDE NO, 33 3'-0" DOOR TO MATCH AND BE INTEGRATED w/ KITCHEN MILLWORK EXTENSION JAMBS AS REQ'D. WHEN LOCATED IN A NET AREA 13 BATH #1 I (I.E. SHOWER) PROVIDE PREFIN15HED INTERIOR w/ VINYL EXTEN5ION JAMB5. EXIST. I 34 INTEGR TYTOF COLUMN/OPEN HOOD PTOST/1DEGK JOIST FLOOR DECK EVALUATE HOT NOTIFY ARCHITECT Imo- GLOS I NOTE: r-- -- OF EXISTING CONDITIONS; PROVIDE $10 K ALLOWANGE FOR REPAIR CONTRACTOR TO VERIFY ALL CEILING 8 FRAMING HE16HT5 A5 WELL AS CABINETRY AND BUILT IN HEIGHTS PRIOR TO I ORDERI NG DOORS OR WI 1- GENERAL UTILITY NOTES: 12 3 --- --- I I I. THE HVAG CONTRACTOR SHALL VERIFY THE 51ZE AND F ' ❑O I PERFORMANCE OF THE EXISTING 5Y5TEM(S) AND CALCULATE DIVERSIFIED DESIGN ASSOCIATES ARCHITECTS, P.C. I THE NEW REQUIREMENTS TO DETERMINE IF THE EXISTING 255 MAIN STREET SUITE 200 H U N T I N G T O N, NY 1 1 7 4 3 - - - - - - - - - - - - - - - - ___ ___ EXIST. I P. 631.271.5400 WWW.DDANY.NET ,a. EXISTING LIVING ROOM SYSTEM 5 WILL BE ADEQUATE TO ACCOMMODATE THE NEW ADDITION. IF THE SYSTEMS) ARE NOT ADEQUATE, THE Copyright ©2025 AIIRightsReseved. 1 --- --- FOYER I GENERAL CONTRACTOR SHALL INCLUDE IN HI5 BID THE C05T SEAL: PROJECT NORTH: EL. 0'-0" I OF EXPANDING THE 5Y5TEM(S) AS REQUIRED FOR PROPER. 1 -- --- I I PERFORMANCE. 4 I 7 -- ---- 1 . . I 2. THE PLUMBING CONTRACTOR TO VERIFY THE SIZE OF DN. 22 I EXISTING DOMESTIC HOT WATER SYSTEM AND DETERMINE IF THE EXISTING SYSTEM WILL BE ADEQUATE FOR THE NEW AND 1 1 O I EXISTING LOADS COMBINED. IF SYSTEM IS NOT ADEQUATE, THE GENERAL CONTRACTOR SHALL INCLUDE IN HI5 BID THE 1 1 COST OF EXPANDING THE SYSTEM AS REQUIRED FOR PROVER � NEW � � ��\ I PERFORMANCE. GARAGE 3. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE 51ZE OF EXIST. I PROJECT TITLE: 4 � � � THE EXISTING ELECTRIC SERVICE FOR ADEQUACY IN m i h`. PORCH I PROVIDING NEW ELECTRICAL INSTALLATIONS AS SHOWN. RENOVATIONS & ALTERATIONS TO THE: 0 4%L. (-) O'-7 I/2" I UPGRADE SERVICE, METER, PANEL, ETG. AS REQUIRED. ALL r 2 I \ 10 i z \ I ELECTRICAL WORK TO BE FIRE UNDERWRITERS INSPECTED AND APPROVED. SUBMIT CERTIFICATE TO OWNER UPON M c N E I LL RESIDENCE I -a I RECEIPT. THE GENERAL CONTRACTOR SHALL INCLUDE IN HI5 _____ I ____ i < BID THE COST FOR THE UPGRADE AND ALL RELATED \ � �114511 ELEGTRIGAL REQUIREMENTS. 710 OLD MENHADEN ROAD WALL LEGEND CUTCHOGUE , NEW YORK 11935 I 1 I i I N.T.S. DRAWING TITLE: 4 4 - _ WALL5/6ON5TRUCTION TO BE REMOVED. PATCH/REPAIR ALL FIRST FLOOR PLAN I I i I SURFAGE5 ADJACENT TO DEMO WITH MATERIALS TO MATCH d b I i 5 I i I AND ALIGN FLUSH WITH EXISTING. NOTES AND DETAILS G = INSTALL SMOKE DETECTOR AND CARBON MONOXIDE STATE ANDrLOCAL CODE REQUIREMENTS IN ACCORDANCE L . NGITH LE LL NEW WALL CONSTRUCTION: � 1 AND MULTIPLE STATION SMOKE ALARMS AS PER INTERIOR WALLS: U.O.N. - - - V THE RESIDENTIAL CODE OF NY5 R-314, R-315 AND Y2" GYPSUM WALL BOARD OVER 2"x4" WOOD STUDS ® Ib"o.c. AJ801.3.1, WIRED 1N 5ERIE5 EXTERIOR WALLS: U.O.N. 'HYDR06AP' HOUSE WRAP AS MANUF. BY BENJAMIN OBDYKE 14'-5" (+/- V.I.F) NOTE: OVER Y2" COX PLYWOOD OVER 2"xb" WOOD STUDS ® 16" o.c. INTERIOR DOOR NOTE: FIRST FLOOR TOP PLATE TO BE SET 50 NEW SECOND PROVIDE AND INSTALL SOLID GORE 13/8' PRE HUNG PRIMED I"/ a�2° R-21 GATT INSULATION AND Y2" GYPSUM WALL BOARD. DRAWN BY: SDE SHEET NO. FLOOR ALIGNS w/ EXIST. (V.I.F) INTERIOR DOORS, STYLE 4 5TIGKIN6 TO MATCH EXI5TIN6. NEW FOUNDATION WALL 5UBFLOOR NOTE: NOTE: PROVIDE AND INSTALL DOOR HARDWARE TO MATCH EXISTING. CHECKED BY: 5J5 WHERE NEW F.J. AND EXIST. F.J. MEET, 5015FLOOR IS TO PREP 4 PAINT ENTIRE INTERIOR GEILIN65/ WALLS/ TRIM IN DOORS ADJACENT TO INTERIOR AND EXTERIOR CORNERS STRADDLE POINT OF BEARING (TYPJ OWNER SELECTED COLORS SHALL BE SET 4 Y2" TO R.O. TO ALLOW FOR OWNER SELECTED EXISTING WALL CONSTRUCTION TO REMAIN DATE: 10.20.25 TRIM. DOORS FOR CLOSETS, LINEN CLOSETS, PANTRIES ETC. Awl � Iffi-l' I RIST f::LCCR FLA I � NOTE.- SHALL BE CENTERED WITHIN WALL LENGTH U.O.N. NOTE: EXISTING WOOD FLOORS ARE TO BE SANDED AND REFINISHED NOTE: SCALE: AS NOTED ALL DIMENSIONS TAKEN TO FIN15H MATERIALS - GYP. IN OWNER SELECTED COLOR. WATER BASED FINISHES ARE TO MIN. TRIM ALLOWANGE- PAINT GRADE TO MATCH EXISTING (NO ALL GYPSUM WALLS AND CEILINGS ARE TO BE TAPED AND 5PAGKLED (THREE A104 1/4" = I'-O'" BD. 4 PLYWOOD BE USED. MDF TRIM): GOATS) AND PAINTED WITH ONE GOAT PRIMER AND TWO GOATS FINISHED COLOR PROJECT N0. 2515 -3 Y2" DOOR 4 WINDOW GA5I45 AS SELECTED BY OWNER. PROVIDE WATER RE515TANT GYPSUM WALL BOARD IN -5 Y2" BASE w/ SHOE MOULDING ALL DAMP/ WET LOCATIONS. I I I CON57RUC71ON NOES �.� u , � � 7{ THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECTS SERVICE,AND ARE AND SHALL 1 LINE OF WALLS BELOW REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER 2 LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE LINE OF ROOF ABOVE SHOWN DOTTED (TYPa ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. O LINE OF CEILING TRAN51TION IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I 4 ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING PATCH AND REPAIR WALL TO MATCH AND ALIGN w/ EXIST. ADJACENT ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION'ALTERED BY' FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE SO RELOCATED ATTIC ACCESS PULL DOWN STAIR; Dl G.J. CONSTRUCTION AROUND OPENING SPECIFIC DESCRIPTION OF THE ALTERATION. IRS PER THE NEW YORK STATE EDUCATION LAW ARTICLE 147-ARCHITECTURE,SECTION 7307► ' � I O6 RELOCATED WINDOW UNIT FROM HALLWAY; PROVIDE NEW CASING TO MATCH EXISTING ISSUANCE: RELOCATED WINDOW UNIT FROM EXISTING LAUNDRY ROOM; PROVIDE NEW CASING TO NO. DATE: DESCRIPTION: MATCH EXISTING O 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING FU OUT WALL AS REQ'D. TO ACCOMMODATE 5HOWER NICHE AND ALIGN w/ RR ADJACENT AS SHOWN WNER CHANGES ® 04.09.26 ADD BASEMENT EGRESS STAIR III O9 REMOVE EXIST. SIDING 8 5HEAT14IN6; GAT ® MID-SPAN PROVIDE)/2" GYP. BD. 10 PROVIDE AND INSTALL OWNER SELECTED OL05ET SYSTEM 11 PROVIDE AND INSTALL CHROME HANGING ROD AND SHELF i ! PATCH AND REPAIR WOOD FLOORING AS REQ'D. (TYP. OF AREA OF WORK, EXCLUDING 12 BATHROOMS) CD PROVIDE AND INSTALL NEW WOOD FLOORING TO MATCH EXISTING; FIN15H w/ OWNER SELECTED WATER BASED FINISHES 14 PROVIDE AND INSTALL OWNER SELECTED TILE FLOORING AND WALL TILE IN WET AREAS 15 OWNER SELECTED 36" VANITY WITH LAV SINK (SEE PLUMBING FIXTURE SCHEDULE) II II 7 I � - - - - 1- - - - - - - - - - - - 1 - - - - - - - - - - - - - 16 17 20 1 O OWNER SELECTED 30" VANITY WITH LAV SINK (SEE PLUMBING FIXTURE SCHEDULE) A-300 I 17 OWNER SELECTED 48" VANITY WITH LAV SINK (SEE PLUMBING FIXTURE SCHEDULE) CONTRACTOR TO OPEN UP EXISTING 15T 4 2ND FLOOR DECK TO EVALUATE STRUCTURAL p 1 O INTEGRITY OF COLUMN/ WOOD POST/ DECK JOISTS 8 2x TRIM BOARDS. NOTIFY ARCHITECT OF NE BATH 4 15 EXISTING CONDITIONS; PROVIDE $10 K ALLOWANCE FOR REPAIR 23 # RENO• 19 OWNER SELECTED TILE 5HOWER PITCHED TO DRAIN; COORDINATE OWNER REQUIREMENTS 1 BATH #5 ' I FOR PLUMBING ACCESSORIES; SEE PLUMBING FIXTURE SCHEDULE = 2'4"xb'8' 14 23 ;� 21 17 1 RENO• 20 OWNER SELECTED TEMPERED 6LA55 SHOWER SURROUND EXIST. `r 4'-II I/8" (EQJ 4'-II I/8" (EQJ ' I BALCONY 42" HIGH WALL TO BE GAPPED w/ OWNER SELECTED MATERIAL 4 TEMPERED 6LA55 24 BEDROOM #3 2O 1 21 SHOWER 5URROOND I 10 RENO• 1 IS 22 REPLACE EXISTING WINDOW SASH w/ TEMPERED UNIT I _+ WALK-IN 0 I I m 4 I I6 — — — — — — GD PROVIDE BATHROOM EXHAUST FAN VENTED TO EXTERIOR NEW /NALK IN 1O i 24 PATCH AND REPAIR WALL TO MATCH AND ALIGN W/ EXIST. ADJACENT INCLUDING SIDING AND INSULATION 6 I/ ter --6'-6" ------ 4 x I I 2 STRUCTUR L KU S SORBI-AVA ENGINEE ING A R EQ't 5 r — — T — — I AL N 5D 12 z I 1 ENGINEER: 169 COMMACK ROAD ----- - -- - — - I SD I \ C I 1 SUITE H-362 =TW3 (T) - 4 i �— — — G� I 15 ALIGN 5-6"+/ I 1 COMMACK, NY 11725 \ RENO — — — — — 631-355-5556 i BEDROOM #I --1 I GLOS• II RE10. u (2) 2'6"xb'8" I 2 BAH #4 \ NEW ,....,...,.r.:h.. \ 5D EXIST. HALL \BATH #2 14 1 p 20 r 1 ALIGN �\ i &7j EXIST iq I I NEW- - - - - - - - — - - - N 15 14 �- - - - - - - - - - - - - - - - - - J Lm 1 6H I / YEI �T CALCULAT1 ® I �5BEDROOM #4 Ir bta PD. NEW BEDROOM #4 REQUIRED LIGHT TRANSMITTING AREA -- °I I AREA = 182.6 50.FT. 182.6 50.FT. X 6% = 14.6 50.FT 6 . „ . PROP05ED WINDOW LIGHT TRANSMITTING AREA=30.a 50.FT. REQUIRED AIR VENTILATION AREA = I q --- -- G 12 1 I I 1152.6 50.FT. X 4% = 1.3 50 FT. 4 -_ 1 -0 4 I/2 - I KENO i i PROPOSED WINDOW AIR VENTILATION = 17.0 SQ.FT. DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. 1 BEDROOM #2 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 NEW 4 RENO, REQUIRED LIGHT TRANSMITTING AREA = P. s 31.2 71 .5400 www.DDANY.NET I I I BATHROOMS NOT REQUIRED WHERE ARTIFICIAL LIGHT IS PROVIDED Copyright 02025 All Rights Reserved. I I' II 2 -- I I REQUIRED AIR VENTILATION AREA = (' �' I I 1 SEAL: PROJECT NORTH: I �I li III I ill fill, I'� NOT REQUIRED WHERE LOCAL EXHAUST IS PROVIIDED � li EQ. EQ. I I x � 1 2 6 - t _ NOTE: � _I : 2 61 13'-4" I N `9 1 rr .. I I 1 I 1 DOOR R.O. TO BE SET 41'2 OFF OF INTERIOR 1, 7 13'-10 1/2" 1 RANO. I 1 I I AND EXTERIOR CORNERS TO PROVIDE ROOM k FOR OWNER SELECTED TRIM. , F, 1 I I MIN. TRIM ALLOWANCE- PAINT GRADE AS HI 11 I I SELECTED BY OWNER: 1 3 Y 1 - - - -I- - - - - - - - - - - - - - - J -3Y2" DOORS WINDOWGA5ING L - — — — — — — — — — 22 -5 Y2" BASE w/SHOE MOULDING 1 1 1 PROJECT TITLE: SD = RENOVATIONS & ALTERATIONS TO THE: G INSTALL SMOKE DETECTOR AND CARBON MONOXIDE DETECTORS IN ACCORDANCE WITH ALL 1 ! I! STATE AND LOCAL CODE REQUIREMENTS. SINGLE AND MULTIPLE STATION SMOKE ALARMS As PER M c N E I LL RESIDENCE I ' la' I i, ' I I' I' I it I ! � THE RESIDENTIAL GORE OF NYS R-314, R-315 AND q C --- I AJ801.3.1, WIRED IN SERIES . I I Il,i III l - 710 OLD MENHADEN ROAD } I I ( p' j WALL LEGEND CUTCHOGUE NEW YORK 11935 N.T.S. DRAWING TITLE: WALL5/6ON5TRUCTION TO BE REMOVED. PATCH/REPAIR ALL ! F SURFACES ADJACENT TO DEMO WITH MATERIALS TO MATCH SECOND FLOOR PLAN AND ALIGN FLUSH WITH EXISTING. 4 I r NOTES T AND DETAILS I NEW WALL CONSTRUCTION: L ' I --_--———_—-----_——_—= i J� INTERIOR WALLS: U.O.N. - _ .- - ! Y2" GYPSUM WALL BOARD OVER 2"x4" WOOD STUDS ® I6"o.c. EXTERIOR S: U.O.N. 'HYDROGAP' HOUSE WRAP AS MANUF. BY BENJAMIN OBDYKE NOTE` OVER Y2" CDX PLYWOOD OVER 2"W WOOD STUDS ® 16" o.c. PREP 4 PAINT ENTIRE INTERIOR CEILINGS/ WALLS/ TRIM IN W/ �2' R-21 GATT INSULATION AND Y2' GYPSUM WALL BOARD. OWNER SELECTED COLORS DRAWN BY: 50E SHEET NO. NEW FOUNDATION WALL NOTE' CHECKED BY: �j..IS EXISTING WOOD FLOORS ARE TO BE SANDED AND REFIN15HED NOT IN OWNER SELECTED COLOR. WATER BASED FIN15HE5 ARE TO PROVIDE 22"x30 ACCESS INTO EXIST. ATTIC EXISTING WALL CONSTRUCTION TO REMAIN BE USED. SPACE THROUGH NEW ATTIC DATE: 10.20.25 - l 05 5r=2C0N1:) �`LCCR FLAN WHERE NEWF.J. AND EXIST. F.J. MEET, SUBFLOOR 15 TO ALL ALL GYP5UM WALLS AND CEILINGS ARE TO BE TAPED AND 5PAGKLED (THREE 5013FLOOR NOTE: NOTE: NOTE: SCALE S NOTED STRADDLE POINT OF BEARING (TYPJ ALL DIMENSIONS TAKEN TO FINISH MATERIALS AEI0 1/4" = I'-O" - GYP. BD. 4 PLYWOOD COATS) AND PAINTED WITH ONE COAT PRIMER AND TWO COATS FINISHED COLOR PROJECT NO. 2515 AS SELECTED BY OWNER. PROVIDE WATER RE515TANT GYPSUM WALL BOARD IN ALL DAMP/ WET LOCATIONS. i CON57RUC71 ON N07EB THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE,AND ARE AND SHALL 1 ROOF CONSTRUCTION REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE - 5/g" COX PLYWOOD SHEATHING INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER - Iq" WIDE FELT PARALLEL TO EAVE5 LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL - 36" WIDE STARTER STRIP OF WEATHER WATCH (MIN. REFER TO ROOFING NOTE #1 ON A-100) COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. - (1) # 30 FELT UNDERLAYMENT IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION - LIFETIME ARCHITECTURAL ASPHALT SHINGLES TO MATCH EXISTING OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING 2 CONT. LOW PROFILE RIDGE VENT. RIDGE VENT SHALL BE SHINGLE VENT ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION'ALTERED BY' _ I I AS MANUFACTURED BY 'AIR VENT' FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION 3) SUPPLY 36" WIDE WEATHER WATCH VALLEY FLASHING IN ALL VALLEYS (TYP) LAW ARTICLE 147-ARCHITECTURE,SECTION 7307) I O4 LINE OF WALL BELOW (TYPa ISSUANCE: ' G N0. DATE: DESCRIPTION: WEAVE NEW ROOF SHINGLES INTO EXIST. 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING PROVIDE LAY-ON ROOF OVER VALLEY CREATED WHERE NEW ROOF MEETS ®O 04.09.26 EXISTING FOR PROPER DRAINAGE (MIN. 3 PITCH) ADD SLID PER OWNER CHANGES BASEMENT EGRESS STAIR PATCH AND REPAIR EXIST. ROOF AS REO'D. CD I I ' I I - - - - - - - - - - - - - - - II I i I A-300 — 1- - - - - - - - - - - - -1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - --ll II II II II II II II II II II II II II II II II II II 4 II II 1 II II II II - - - - - - I STRUCTURAL KUROS SORBI-AVA ENGINEERING 3 I I ENGINEER: 169 COMMACK ROAD I 5 I I SUITE H-362 COMMACK, NY 11725 — � I I 631-355-5556 II II 2 - - - - - - - - - - I F S "g ( 3 I I DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. II 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 IP. 6 31.2 71 .5 4 0 0 WWW.DDANY.NET - - - - - - - - Copyright 02025 All Rights Reserved. - - - - - - - - - - I SEAL: PROJECT NORTH: , I II11i II II INSTALL NEW PLUMBING VENTING SYSTEM. ' Y I I INSTALL AT LOCATION ABOVE ROOF. I I ALL INSTALLATIONS ARE TO COMPLY li z' I— — — — — — — — — — — — — — I I — — — — — — — — — — — — — j THE NY5 RESIDENTIAL CODE4 NY5 /^ I � - - - - - - - - - - - - - PLUMBINSGODE. 2 \ PROVIDE WEATHERPROOFING ROOF JACK W/ NEOPRENE GASKET \ PROJECT TITLE: 3 I I 4 AROUND VENT. \ / \ RENOVATIONS & ALTERATIONS TO THE: \ � INSTALL NEW \ McNEILL RESIDENCE _ _% `� _ _ _ _�j FLASHING ® ROOF. Q \ I � 710 OLD MENHADEN ROAD I I ': I � I CUTCHOGUE NEW YORK 11935 I I I�I i �I I I I I d i t I� I i i, // III I II DRAWING TITLE: ROOF PLAN NOTES AND DETAILS ROOF VENT DETAIL I' I INSTALL ROOFING SHINGLE DRAWN BY: SDE SHEET NO. SYSTEM TO LAP OVER FLASHING ® SIDES AND TOP. CHECKED BY: SJS DATE: 10.20.25 A e Al 06 R00f= FLAN 2 ROOF! =N T �ETAIL NOTE- VENT TERMINAL TO COMPLY WITH NY5 SECTION SCALE: AS NOTED A 106 1/4" = rl A 106 N.T.S. P3103.2 d P3103.1.1; SEE A-100 PROJECT NO. 2515 I r-RAMIN6 NOTE5 THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY 1 THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE,AND ARE AND SHALL LINE OF ROOF ABOVE SHOWN DOTTED (TYPJ REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER 2 P05T FROM ABOVE TO BEAR 50LIDLY ON HDR. 5HOWN DOTTED (TYPJ LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL 3) POST FROM ABOVE TO BEAR SOLIDLY ON GIRDER/ FDN. BELOW (TYi-'J COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION 4 OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I PROVIDE SOLID 4x4 POST IN WALL UNDER HDR. ABOVE ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION'ALTERED BY 5 FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE PROVIDE SOLID bxb POST IN WALL UNDER HDR. ABOVE SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION LAW ARTICLE 147-ARCHITECTURE,SECTION 7307) 6 PROVIDE 4x6 PARALAM P05T IN WALL UNDER HDR. ABOVE ISSUANCE: O7 SET TAIL TO AL16N w/ ADJACENT (5EE ELEVATIONS) NO. DATE: DESCRIPTION: OATTACH F.J. TO HDR. ABOVE w/ 'SIMP50N' (HU210) 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING -n7ff=uW ER CHANGES EXIST. (D1"xb"x NEW 3Y2" 5GH. 40 5TL. P05T HDR. ABOVE TO BEAR 50LIDLY ON FDN./ 61RDER BELOW; PROVIDE 04.09.26 ADD BASEMENT EGRESS STAIR DECK YY 5TL. GAP PLATE FOR FULL BEARING; 5EGURE 5TEEL BEAM w/ (4));'2" DIA. BOLT5 (NO WORK) -�O'EL. (-)I'-3 1/2" 10 PACK 5TL. BEAM 50LID w/ 2x A5 REQ'D. FOR J015T ATTACHMENT 11 EX15T. ATTACH 2x6 G.J. TO BOX BM. Pi/ SIMP5ON' (HU2(5) O PqORK) ( 1 (N PATIO DATTACH FLU5H HDR. TO FLUSH HDR. w/ 'SIMP50N' (HU51.bIA0) EL. (-)I -6 3/4 13 ATTACH EXIST. FLUSH HDR. TO FLU514 HDR. w/ 'SIMP50N' (HU210-2) F- — — 14 VERIFY IN FIELD AND NOTIFY ARCHITECT OF ANY DI5GREPANCIE5 ON, I 5 1 (2) 2x10 (2) 2x10 A-300 L _EXIST. FLU5H HDR. F= HDR. I. HDR. (2) 2x10 HDR. TO REMAIN - - - - - 1 DN. QII II LE III 2x 8 I x 000 EXIST,NEN I NEW PORCH I .� EX15T. 2x10 F.J. — EAT-IN HOME OFFICE O.G. w ® AREA (NO WORK) I I I ® I6 I X i III 1 x 8 III a 2 � ( f a III 2) 2x10 DR. 2 W8x28 FLU514 HDR. 7--( RENOVATED OftY z 3 v IY pCKITCHEN p EX15T. 2x10 F.J. cN 13 STRUCTURAL KUROS SORBI-AVA ENGINEERING O N NEW LAUNDRY N ® O ® I6" O.G. 'R tv ® II ENGINEER: 169 COMMACK ROAD N 2xIO LE06ER BD. ( 1i COMMACK, NY 11725 4 RENO• 631-355-5556 x DINING ROOM • `� OWNER'5 — — k1 ® G 05ET w 11; AT RENO, [,`7777`�T Q cN I BATH #1 NI lY NEW DEN O I � ———-- x p � x I EXIST. I I I I I a.2,;,1 m ® I GLO5•AN FF7 I I I I I (2) 13/4"xa Y4"" L.V.L. W/ I' " 5TL. PLT. LL --- --- I I O 0 I I I DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. 6 FLUSH HDR. I UNDER WALL VE ——— ——— I I I (j O I I I 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 I — — — — — — — — — — — — — — _-- I I b EX15T. I I I I P. 631.271.5400 WWW.DDANY.NET I I EXISTING I I � ® LIVING ROOM I Copyright 02025 All Rights Reserved. b I -- --- FOYER I I X (NO WORK) I I I I I EXIST. 2x6 G.J. I -$I EL. O'—D" I I I I 111 I SEAL: PROJECT NORTH: I ® 16" O.G. A I I III I DN. I I I EXIST. 2x8 R.R. NI I I III ® 16" O.G. cN I I I NEN I II I -'\O j ' tY n'- `j \z �? EXIST. \ .(fG� dJ Q p x 6 x ORCH III I PROJECT TITLE: x cN= RENOVATIONS & ALTERATIONS TO THE: (NO WORK) I i \A k/per � DC I 4,4ro\ X ® - 0 ux \ McNEILL RESIDENCE .-' o f �v Id w I� Q i I EXIST. (2) 2x10 HDR. TO REMAIN � p -EIST�2T2XIo To - ry -Ai - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -� 710 OLD MENHADEN ROAD 4 I I 2xbI G.J. 14 CUTCHOGUE NEW YORK 11935 1 o r cV 2x8 R.R. ® I6 I O.G. 2x8 R.R. I 4 NOTE: DRAWING TITLE: N 16, O.G. • ® 16" O.G. I ALL EX15T. MEMBERS ARE A55UMED; NOTIFY ARGHITEGT OF ANY 015GREPANGIE5 F ¢�� o ;�� o UPON DEMOLITION SECOND FLOOR FRAM I N& NOTES AND DETA I LS 2 i cx — I NOTE: I I PROVIDE ALL 'SIMP50N' JOIST HAN6ER5 A5 REOV. PROVIDE CONGEALED HAN6ER5 (2) 2x12 HDR. WHERE REQUIRED. — NOTE: ALL P05T5 SHALL GON515T OF (1) KIN6 5TUD 4 (2) JAGK 5TUD5 U.O.N. 5TAN=)AR1:) HEAI:)ER OU I =�r= DRAWN BY: 5DE SHEET NO. (NOTE: ONLY APPLIGA13LE FOR HEADER5 NOT GALLED OUT ON DRAWIN65) CHECKED BY: 5J5 hm MAX. SPAN HEADER SIZE 21-0" (2) 2x6 D.F. #2 DATE: 10.20.25 7 5E!CONr�) flo-LOOR fl2RAMIN6 FLAN 31-011 (2) 2x8 D.F. #2 SCALE: �t5 NOTED Aml 4-0" (2) 2x10 D.F. #2 A 10-7 1/4" = I'—O"' 6'-0" (2) 2x12 D.F. #2 PROJECT N0. 2515 8'-0" (2) 1 5/4"x a 1/4" L.V.L. 101 -0" (2) 1 5/4"x II 1/4" L.V.L. � I FERAM I N6 NOTES THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY 1 THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECTS SERVICE,AND ARE AND SHALL LINE OF ROOF ABOVE SHOWN DOTTED (TYPJ REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER O LINE OF WALL BELOW (TYPJ LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. 3 PROVIDE SOLID 4x4 POST IN WALL UNDER HDR. ABOVE IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I 4 ATTACH EXIST. G.J. TO NEW FLUSH HDR. W/ 'SIMP50N (HU28) ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION"ALTERED BY - -- - OS SET TAIL TO ALIGN w/ ADJACENT (SEE ELEVATIONS) FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION LAW ARTICLE 147-ARCHITECTURE,SECTION 7307) ISSUANCE: NO. DATE: DESCRIPTION: j 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING REVISED PER OWNER CHANGES ® 04.09.26 ADD BASEMENT EGRESS STAIR I ' i I i 2 — — — — — — — — — — — — — I � - - - - - - - - - - - - ', II I i - - - 1 - - - - - - - - - - - -I - - - - - - - - - - - - - - - - - - - - - -- � 1 (2) 2x8 HDR. A-300 1 I IA I I = I O I I W BATH #3 u v I � a (Z d p � � IEXIST. x p EXIST. NEW v RENO. x ® 1 BALCONY BEDROOM #3 WALK-IN WALK-IN — Lu I- — GL05. �x p GLOS. ® RENO. I _x ® N uu BATH #5 I lu I x _ 4 - - X - - - - - - - — 2)12x8 GONT FLUSH HDR. — - - - - - — — — — - - - - - - - - ---- 4 4 / :rill, _ _ � — --- --- — __+ _ _ _____ _ — v -j v ENGINEER: 169 COMMACK ROAD - - �p —_ =-1 =_ ( / I v O v O I I SUITE H-362 _ ----=— --- (2) 2x8 HDR. �0� i I x .fl �.o �i v COMMACK, NY 11725 - _ ® ® � v � �? 0 x o x o x O RENO. L - - - - - 631-355-5556 �,r N=% "= BEDROOM #1 GLO5. Q Q ��i� [2xb I R.R. _ — — _ — I T� ® 161o.G / w I RENO. \ I Lu W 1 O lu I 4 ATH # BAT w#2 E�15T. ALL 3 2 1 3/," �y„ I ,. L.V.L. FLI�5H 2 1 3 "x I A ry f v - - L.V.L. FLU 51�1 HE, - —1 3/4"x a y4" L.VL. R.B. NEW � � --- -- 3 / I ❑ ❑ 4 - - - - - - - - - - - - - BEDROOM #4 ® --- -- / 3 - -Z DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. �ry EXIST. 12x8 G.J. ry __ 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 i ® I6�' O.G. I Ij \ (2) I i3/4°X 1 Y4°I:L:V.LI HDR ! "' _ __ I I RENO' P. 631.271.5400 WWW.DDANY.NETrve Copyright 02025 All Rights Resed. I; I'll �' Q M BEDROOM #2 I I SEAL: PROJECT NORTH: r`9 i I EXIST. x8 R.R. EXIST. 2x8 (�.R. -- -- I ® I6" O.G. I ® 16" O.0 11 I R I I - II I I II I III I-I- - — — — — — — — — — — — — —i- - - - - - - - - - - - - - - -� I I II PROJECT TITLE: RENOVATIONS & ALTERATIONS TO THE: L - —I,il 1 �� �I -_--- J McNEILL RESIDENCE ' I'-"�I I i� I � f'`� '�� ill I', i - 710 OLD MENHADEN ROAD CUTCHOGUE NEW YORK 11935 DRAWING TITLE: O Ii 'I! ill ji ili III Ili �I N TE. ALL EXIST. MEMBERS ARE ASSUMED; NOTIFY ARCHITECT OF ANY D15CREPANGIE5 ROOF FRAMING PLAN I UPON DEMOLITION NOTES AND DETAI S �i NOTE: L PROVIDE ALL 'SIMP50N' JO15T HAN6ER5 A5 REQD. PROVIDE CONGEALED HANGERS WHERE REQUIRED. NOTE: ALL POSTS SHALL CONSIST OF (1) KING STUD d (2) JACK STUDS U.O.N. 57AN=)AR� Hr=A=�ER S� JI �E DRAWN BY: 5DE SHEET NO. (NOTE: ONLY APPLIGABLE FOR HEADERS NOT GALLED OUT ON DRAWINGS) CHECKED BY: 5J5 MAX. SPAN HEADER SIZE 21-0" (2) 2x6 D.F. #2 DATE: 10.20.25 iffla w 31-O" (2) 2x8 D.F. #2 SCALE: A5 NOTED Al 08 1 R00f=- FRAM I N 6 PLAN- 4-0" (2) 2x10 D.F. #2 A105 1/4" = I'-0" 61-0" (2) 2x12 D.F. #2 PROJECT NO. 2515 8'-O" (2) 1 3/4"x a 1/4" L.VL. 10'-0" (2) 1 3/4"x II 1/4" L.V.L. I I ROOF CONSTRUCTION NOTES: NEW ROOF CONSTRUCTION THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE,AND ARE AND SHALL CONT. LOW PROFILE RIDGE VENT. RIDGE / / - 5/g" COX PLYWOOD SHEATHING REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE VENT SHALL BE SHINGLE VENT 11 AS / / - Iq" WIDE FELT PARALLEL TO EAVE5 INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER MANUFACTURED BY 'AIR PENT' - 36" WIDE STARTER STRIP OF WEATHER WATCH (MIN. REFER TO LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE ROOFING NOTE #1 ON A-100) ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL - (I) 30 LB. FELT UNDERLAYMENT COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. -LIFETIME WARRANTY ASPHALT ROOF SHINGLES TO MATCH EXIST. IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION / I OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I 36" WIDE WEATHER WATCH VALLEY / / A-300 ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING FLASHING IN ALL VALLEYS (TYPJ WALL CONSTRUCTION NOTES: ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION'ALTERED BY' UI-I FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE NEW WALL CONSTRUCTION SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION ■ GYP. E3D. LAW ARTICLE 147-ARCHITECTURE,SECTION 7307) z / / -2"xb WALL STUDS ® I6" O.G. w/ R-21 BATT INUSL. Q -y2" COX WALL SHEATHING ISSUANCE: u�l I Q I = _I 5� O6ANYHO MATCH EXIST. NO.BENJAMIN OBDYKE N0. DATE: DESCRIPTION: __ ____ __ _ r R E WRAP AS MANUR - - - -- IDING :VINYL SIDING TO 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING LL - ---- TRIM AND FASCIA NOTES: REVISED PER OWNER CHANGES a W FASCIA: 2x ADD BASEMENT EGRESS STAIR SUB-FASCIA WRAPPED Pi/ WHITE ALUM. UNDER NEW _ - -- _---_ GUTTERS (TYPJ FLYER: Ix8 'VERSATEX' TRIM BD. OVER 2x8 FLYER (TYPJ IJU ®I J,EXIST. SECOND F OOR LATE HEIGHT EL: 17'-1I I/2" - - - — - _I CORNER BOARDS CORNER BOARDS TO MATCH EXISTING / / WINDOW SURROUNDS: VINYL WINDOW SURROUND TO MATCH EXISTING z I / / SOFFIT: VINYL VENTED BEAD BOARD SOFFIT TO MATCH EXISTING _ J,4 Q !� .�9� r:J� E E J E PROVIDE AND INSTALL 5" WIDE C�l1TTER5 AND LEADERS TO BE Q � J\ TIED INTO EXIST. DRYWELL (TYPJ ztY I WEAVE NEW ROOFING INTO EXIST. (TYPJ - - :- 0 = EXISTING WINDOW/ DOOR NEW WINDOW - ® = RELOGATED WINDOW EXIST. SECOND FLOOR HEIGHT EL: q'-II I/8" PROVIDE ROOF TO WALL FLASHING 4 51DEWALL STEP FLASHING AS REQ'D. 1�01 (TYPJ IRJ11E 111E® Em® rn� �� E E E E OWNER SELECTED LIGHT FIXTURE WIRED L E � I I TO SWITCH (TYP) O I I PARGE EXPOSED FDN. AS REQ'D. TO mom 111E 111E I [] MATCH EXIST. (TYP) EXIST. FIRST FLOOR HEIGHT EL: 0'-0" E FM - - - - - - - - - - - - - EXIST. AVG. GRADE EL:_(- I'-q Y2' - ; 1 ; 1 I 1 I 20'-011 z 21'-10 1/2" --f — — — — rT ---------------------- -- ------- ----------------------- — --- 1 , 1 I I 1 I I 1 I 1 1 ' STRUCTURAL KUROS SORBI-AVA ENGINEERING LINE OF FOUNDATION/ FOOTING SHOWN ENGINEER: 169 COMMACK ROAD DOTTED (TYP) ----; L---------; SUITE H-362 COMMACK, NY 11725 1_________; 1_________________i L_ , I Ir -----------------------------------T- -----------------------------------------------------------------------------------------------------------------------------------------------T------------------------------------------, 631-355-5556 PROVIDE STEP FOOTING AT 2'-0" MAX. I I I I `------------------ HORIZONTAL AND 1'-0" MAX. VERTICAL I I 1 1 1 I I FRONT ELEVATION A2C O 1/4" = 1'-O" (SOUTH ELEVATION) ' 1 P''300 \ CONT. LOW PROFILE RIDGE VENT. RIDGE VENT SHALL BE SHINGLE VENT 11 AS MANUFACTURED BY 'AIR VENT' Lu ry O g z ' Ca DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. - I IQ 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 \ \ Q V P. 6 31.2 71.5 4 0 0 WWW.DDANY.NET \ \ z Copyright ©2025 All Rights Reserved. z F- SEAL: PROJECT NORTH: EXIST. SECOND FLOOR PLATE HEIGHT EL: 17'-II 1/2" v — . — . 10 ro I� Iz nrri Auc, CONTRACTOR TO OPEN UP EXISTING I5T 4 ■ M 2ND FLOOR DECK TO EVALUATE E E ® STRUCTURAL INTEGRITY OF COLUMN/ WOOD NOTIFY ARCHITECT OF EXISTI G BOARDS. \ \ CONDITIONS; PROVIDE $10 K ALLOWANCE ------ ---- - ----------------------------- ------------- FOR REPAIR I I PROJECT TITLE: \ \ RENOVATIONS & ALTERATIONS TO THE: ,,&EST. SECOND FLOOR HEIGHT EL: q'-II I/8" _ � PROVIDE ROOF TO WALL FLASHING 4 McNEILL RESIDENCE 51DEWALL STEP FLASHING AS REQ'D. p 1 (TYPJ , I I ®® p C r 710 OLD MENHADEN ROAD rN- ) ' CUTCHOGUE , NEW YORK 11935 u ri E ®'�R N N n m r OWNER SELECTED EXTERIOR GRADE DRAWING TITLE: GUARD RAIL AND HAND RAIL o EXTERIOR ELEVATIONS I E ri® PARGE EXPOSED FDN. AS REQ'D. TO I I - MATCH EXIST. (TYP) ,b EXIST. FIRST FLOOR HEIGHT EL: O'-0" _ LINE OF FOUNDATION/ FOOTING SHOWN DOTTED (TYP) ,b_EXIST. AVG. GRADE ,v I i �-----------' i i I ' ' I E ST. ; NEW I -- 20'-0" DRAWN BY: 50E SHEET NO. 21'-10 1/2" I I I I I ---J CHECKED BY: 5.J5 ---J L DATE: 10.20.25 _ 2® 0 I I I I I I I SCALE: R5 NOTED i i i i i 2REARELEVAT ( ON ____________________________�_ --------- -----r--F------------------------------------------ I -; PROJECT NO. 2SIS ------------------------------�------------------------------------------------------------------------------------- ------------------------------------------------------,- I OVIDE STEP FOOTING AT 2'-0" MAX. 1 , A200 1/4" = r-o- (NORTH ELEVATION) HORIZONTAL AND I -0 MAX. VERTICAL 777777 777 I ROOF CONSTRUCTION NOTES: � 1 } NEW ROOF CONSTRUCTION THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY THE ARCHITECT ARE INSTRUMENTS OF HE ARCHITECT'S SERVICE,AND ARE AND SHALL GONT. LOW PROFILE RIDGE VENT. R D6 - /8 COX PLYWOOD SHEATHING REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE s �� VENT SHALL BE SHINGLE VENT 11 AS - la" WIDE FELT PARALLEL TO EAVES INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER MANUFACTURED BY 'AIR VENT' - 36" WIDE STARTER STRIP OF WEATHER WATCH (MIN. REFER TO LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE ROOFING NOTE #1 ON A-100) ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL - (1) 30 LB. FELT UNDERLAYMENT COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. -LIFETIME WARRANTY ASPHALT ROOF 5HIN6LES TO MATCH EXIST. IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I 36 WIDE WEATHER WATCH VALLEY ANY WAY.WALL CONSTRUCTION NOTES: ARCHITECTIF ANY ITEM SHALL AFFIX SEAL ITO HE ITEM ALONG WITHNG THE SEAL OF AN TECT IS THE NOTATERED THE ION ALTERED BY ALTERING FLASHING IN ALL VALLEYS (TYP) FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE NENHALL CONSTRUCTION SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER HE NEW YORK STATE EDUCATION -- -_ -- -- '�2" GYP. BO. LAW ARTICLE 147-ARCHITECTURE,SECTION 7307) PATCH AND REPAIR SIDING TO MATCH - -- 1,_ -2"x6' WALL STUDS ® 16" O.G. W R-21 BATT INUSL. AND AL16N W/ EXIST. ADJACENT (TYP) _ -Y2" COX WALL 5HEATHIN6 ISSUANCE: --'HYDRO6AP' HOUSE WRAP AS MANUF. BY BENJAMIN OBDYKE 12 N0. DATE: DESCRIPTION: -SIDING :VINYL SIDING TO MATCH EXIST. PATCH AND REPAIR SIDING TO MATCH 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING -_ -== AND AL16N w/ EXIST. ADJACENT (TYPJ TRIM AND EASG 1 A NOTES: -17VISLU PLR OWNLR CHANGES -_-_ - FASCIA: 2x SUB-FASCIA WRAPPED w/ WHITE ALUM. UNDER NEW ® 04.09.26 ADD BASEMENT EGRESS STAIR 6UTTER5 (TYP) PROVIDE ROOF FL WALL FLASHING d FLYER: Ix8 'VER5ATEX' TRIM BD. OVER 2x8 FLYER (TYP) EXIST. SECOND FLOOR PLATE HEIGHT EL: 17'-11 1/2° 1 -- _ 51DEWALL STEP FLASHING AS REQ'D. CORNER �— — — <'' y>_ (TYP) TO MATCH EX15TIN(5 NDOW SURROUNDS: VINYL BONDOWSURROUND TO MATCH EXISTING 1 --AL-IGN SOFFIT: VINYL VENTED BEAD B G BOARD SOFFIT TO MATCH EXISTIN PROVIDE ROOF TO WALL FLASHING GONT. LOW PROFILE RIDGE VENT. NOTE: 51DEWALL STEP FLASHING AS REQ'D. J RIDGE VENT SHALL BE SHINGLE PROVIDE AND INSTALL 5" WIDE GUTTERS AND LEADERS TO BE (TYP) _ R VENT 11 AS MANUFACTURED BY TIED INTO EXIST. DRYWELL (TYP) fl 'AIR VENT' ----------------------- -------- O EXISTING WINDOW/ DOOR - - _- LINE OF EXIST. ROOF 5HOWN DOTTED QN = NEW WINDOW EXIST. SECOND FLOOR HE16HT EL: a'-II 1/8" RELOCATED WINDOW — - — . — 12 I ' r-0 ALI6 I r_6r1 1 OWNER SELECTED EXTERIOR GRADE GUARD RAIL AND HAND RAIL R ''N "11 C EI LJ 111117 PARGE EXPOSED FDN. AS REQ'D. TO E .n ® N MATCH EXIST. (TYP) DE El E 11c OWNER SELECTED L16HT FIXTURE 71 r 17.1171 1171 ' TO 5WITCH (TYP) SEXIST. FIRST FLOOR HEIGHT EL: O'- — EXIST. — GRADE E 1 I I F1____________a__1________� I 1 1 I6"x8" GRAWL SPACE VENT w/ INSECT ' '--------;"-- i ? , -- -----; NEW EXIST. EXIST. NEW SCREEN ; ; -----=--------;--------; ; z i I 1 1 I 1 1 1 , f1J-_____________y--------. k y 1 r ___________________________________________________________________—______________________________—______________________________i i LINE OF FOUNDATION/ FOOTING SHOWN � ------ ---- I m 1 1 y------------ --------------------- ----------------------------- -----------------L---------------------------------------------- ------- �--------r-- r--------------------------------------------------- T------------- STRUCTURAL KUROS SORBI-AVA ENGINEERING i i m i 169 COMMACK ROAD DOTTED (TYP) r,____>__________+_______-, 1 1 I EXIST. ' + r ;----- ;-- - ALIGN ALIGN ENGINEER: PROVIDE STEP FOOTING AT 2'-0" MAX. 1 -----` T ----, SUITE H-362 1 , HORIZONTAL—AND I'-0" M VERTICAL - +--; COMMACK NY 11725 ------------�t---- PREVIOUSLY INSTALLED FOOTING TO BE -;- --------------------------- ---------------`-----r--; ;------- -------------;i----------------------------------- T------------------------------------------------------------------------------ 631-355-5556 --J---L--------------------'--�---; 1 1 I 1 CHOPPED AS REQ'D. INSTALL L-------------------------------------------- E------- ------------J-------------------------------- - 1 1 - -------L------------------------------------------------------------------------------- UNDERPINNING AS REQ'D. (SEE A-103 FOR L--------------------------- �'--- M RE DET 15) t^, 1� L.Ef=T ELEVATION A201 1/4° = r-0" (WEST ELEVATION) J. t DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 P. 631.271.5400 WWW.DDANY.NET Copyright ©2025 All Rights Reserved. SEAL: PROJECT NORTH: hEXIST. SECOND FLOOR PLATE HE16HT EL: I7'-II 1/2" — � J CONT. LOW PROFILE RIDGE VENT. RIDGE VENT SHALL BE 5HIN6LE VENT II AS MANUFACTURED BY 'AIR VENT' 36 WIDE WEATHER WATCH VALLEY E ELEDJ FLASHING IN ALL VALLEYS (TYP) La PROJECT TITLE: RENOVATIONS & ALTERATIONS TO THE: EXIST SECOND FLOOR HEIGHT EL: Q'-11 1/8" �— - - — - f2 - — - -- ---- - -- -- McNEILL RESIDENCE ±5� 710 OLD MENHADEN ROAD I -o' CUTCHOGUE , NEW YORK 11935 WEAVE NEW SIDING IN w/ EXIST. (TYP) ALI6 DRAWING TITLE: E E I E= E E E EXTERIOR ELEVATIONS LtdPAR6E EXPOSED FDN. AS REQ'D. TO MATCH EXIST. (TYP) EXIST. FIRST FLOOR HE16HT EL: 0'-0" ,,K EXIST. AV6. GRADE EL: (-)I " z ------------ � NEW X EXIST. � � � ; DRAWN BY: 50E SHEET N0. O CHECKED BY: 5J5 ------------------------------------------- 1 1 I 1 1 I 1 L--------------------- ------------------y-----------------------------; I I I 1 DATE: 1 0.20.25 LINE OF FOUNDATIOW FOOTING SHOWNAm201 ALIGN DOTTED (TYP) ! SCALE: A5 NOTED R16HT ELEVA710N PROJECT N0. 2515 1 I 1 I I 2 1 I I 1 I A2'0 1 1/4" = 1'-o" (E,45T ELEVATION) L__ _________________—____________________________________________________1_________-_______________—--------------—__—__________l----------------- J I I I I 1 .'7�_k' i1:E."' .'het - { }a t'r3'• 3/4"x a Y4" L.V.L. R.B. ROOF CONSTRUCTION THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY — 5/8" COX PLYWOOD SHEATHING THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE,AND ARE AND SHALL 2x8 R.R. ® 16" O.G. - la" WIDE FELT PARALLEL TO EAVES REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE „ INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER - 36 WIDE STARTER STRIP OF WEATHER WATCH LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE 2x4 G.T. ® 32" O.G. (TYPJ (MIN. REFER TO ROOFING NOTE #1 ON A-100) ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL - (1) 30 LB. FELT UNDERLAYMENT COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. 2x4 CAMEL BACK ® MID-SPAN MAX. - LIFETIME ARCHITECTURAL ASPHALT SHINGLES TO IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION al-on O.G. (TYP) MATCH EXISTING OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I ANY WAY, IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING 2x8 G.J. ® 16" O.G. w/ R-300 BATT INSULATION IN WINDOW HDR. SEE FRAMING PLAN ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION'ALTERED BY' BAYS. FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE WALL CONSTRUCTION SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION SIMPSON HOLD ON. (TYP) —1/2" (5YP. BO. LAW ARTICLE 147-ARCHITECTURE,SECTION 7307) -2"xb" WALL STUDS ® 16" O.G. w/ R-21 BATT INSUL. 2x SUB-FASCIA WRAPPED w/ WHITE ALUM. (TYPJ - -- -Y2" COX WALL 5HEATHIN6 ISSUANCE: -'HYDRO6AP' HOUSE WRAP AS MANUF. BY _-- NO. DATE: DESCRIPTION: — - 12 BENJAMIN OBDYKE 2x10 F.J. ® 16" O.G. W/ SOLID BRIDGING ® MID-SPAN - -:-::-__ Qg -VINYL SIDING TO MATCH EXI5TIN6 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING 8'-O" MAX. ATTACH TO UPSET HDR. w/ '51MP50N' _ (HU210) (TYP) (2) 1 3/4"xa Y4" L.V.L. w/ I" x a" STL. PLT. FLUSH HDR. ® 04.09.26 ATTIC UNDER WALL ABOVE ADD BASEMENT EGRESS STAIR _ - EXIST. SECOND FLOOR PLATE HEIGHT EL: 17'-II 1/2" 2 1:_6:� WALL CONSTRUCTION �Y ALIGN 11101 A_300 x,46 YWALL STUDS ® 16" O.G. w/ R-15 BATT INSUL. 2x8 R.R. ® 16" O.G. ATTACHED TO 2x10 LEDGER BD. '-611± _ NEW -5/8" GYP. BD. ON GARAGE 51DE OF WALL 2x6 G.J. ® 16" O.G. w/ R-30C BATT INSULATION IN GLOS• r' BEDROOM #4 BAYS. 3/4" T4 6 PLY NO. w/ r 2x8 R.R. ® 16" O.G. SIMP50N' HOLD ON. (TYPJ 6LUE/NAIL (TYP) REMOVE EXIST. SIDING SHEATHING; GAT 4� —GUT BACK EXIST. R.R. AS REQ'D. FOR NEW LAY-ON ROOF MID-SPAN PROVIDE Y2' GYP. BO. — EXIST. GO 00 6 T 2x10 F.J. ®I6" O.G. w/ SOLID YYYYYYYYYYY =--- ----- _- —___ 2 5 EXIST. HDR. TO REMAIN V.I.F. 4 NOTIFY ARCHITECT OF ANY DISCREPANCIES BRIDGING ® MID-SPAN 8'-0" MAX. 4 11-0' _ _ ---- _ PACK UP AS REQ'D. FOR NEW R.R. TO AL16N w/ EXIST. ADJACENT R.R. R-30G BATT INSUL. IN BAYS PROVIDE 5/8" GYP. BO. ON WALLS AND CEILING OF GARAGE (TYP) SOLID BLOCK BELOW WALL CRIPPLE WALL TO BE 2"x4" WOOD STUDS ® ib"o.c. w/ (1) 2x4 ACQ. 51H ` PLATE 4 (I) D. FIR 2x4 SILL PLATE SECURED TO EXIST. SLAB Pi/ P.A.F. 2x10 F.J. ®I6" O.G. w/ SOLID NEW DEN .\ PROVIDE COPPER TERMITE SHIELD BRIDGING ® MID-SPAN 8'-0" MAX. 4 NEW _ R-30G BATT INSUL. IN BAYS LAUNDRY \` NEW GARAGE PROVIDE 4" P.G. SLAB w/ 6 MIL V.B. w/ bxb1% WWM OVER 6" COMPACTED POROUS FILL COMPACTED TO a5% DENSITY w/Y2" EXPAN51ON JOINT ® PERIMETER PROVIDE (R-10) RIGID INSUL. ON 3/4" T46 PLY NO. w/ �, WHERE SLAB MEETS FND. WALLS SEE CONC. 4 FNO. NOTES FOR ADDITIONAL IN E O 6LUE/NAIL (TYP) �� REQUIREMENTS; PITCH SLAB TO GARAGE DOORY8" PER FOOT. SLAB TO MATCH ,� AND ALIGN w/ EXIST. GARAGE SLAB; DOWEL INTO EXIST. SLAB A�)F EXIST. FIRST FLOOR HEIGHT EL: 0'-0" :- ------------------- ---- NEW - . _ . — — i -- i z ---- -"---` ^•.----- ------------ _ EXIST. AV6. GRADE EL: I' 1 ---------------------- CRAW _I I EXIST. 6ARAk6E SLAB ----- ---r-- --- ----.---------- CHOP PREVIOUSLY INSTALLED FOOTING AND IIOVIDE r- SPACE m � z 8" WIDE POURED CONCRETE FOUNDATION WALL w/ (I) #4 VERTICAL BAR UNDERPINNING; SEE A-103 FOR MORE DETAILS _____ ________ I'' a ® 72" O.G. EXTENDED INTO FOOTING, (1) WITHIN 6" OF CORNERS AND I i p OPENIN65, (1) #4 HORIZONTAL REBAR AT TOP w/ 3" COVER w/ 12"x24" a- _________________________ 1: CONTINUOUS FOOTING TO BE 3-0 BELOW GRADE w/ (2) #5 KEBABS _I ,r EXIST. FDN. TO BE REMOVED/ m CONTINUOUS; %" 6ALV. ANCHOR BOLTS ® 23" O.G. SEAM SEAL, COPPER ------ -------------- r i; CHOPPED TO IBE BELOW NEW SLAB FLASHING BETWEEN FOUNDATION 4 (1) 2x4 ACQ. SILL PLATE 4 (1) D. FIR STRUCTURAL KUROS SORBI-AVA ENGINEERING 1 F __________________ -----_----- _ _ T-- ; I 2x4 SILL PLATE ;_t•: ALIGN ENGINEER: 169 COMMACK ROAD SUITE H-362 -------------- ------ _ _ CO 25 _ _ : 8 MMACK, NY 117 ----------------T ------ --------------- °i° - ---- ---- ---- ---- ---- ---- --- ---- --- ---- --- --- ' , • — —' - PROP EGRESS STAIR SLAB E�8 - - I y _ ----------------- ----- - ----------------------------------------------------- . • 631 355 5556 �- :ram ------------------------------ L ( ) 8 8" WIDE POURED CONCRETE FOUNDATION WALL w/ PROVIDE 2" THICK POURED CONCRETE VERMIN SLAB OVER 6 MIL #5 VERTICAL REBAR5 ® 36" O.G. 3" FROM ENDS 4 POLYETHYLENE VAPOR RETARDER:, JOINTS LAPPED 6" MIN., OVER 4" EMBEDDED IN FOOTING. PROVIDE MIN. (2) #5 COMPACTED COURSE GRAVEL;MAIINTAIN MIN. 3'-0" UNDER FLOOR SPACE REBAR5 ® TOP 4 BOTTOM OF WALL (3" MIN. '� 8" WIDE POURED CONCRETE FOUNMATION WALL w/ #4 CONTINUOUS CLEAR) W/12X24 CONTINUOUS FOOTING (TO BEAR ON VIR61N SOIL) W/ (3) #5 REBAR5 CONTINUOUS HORIZONTAL BAR WITHIN 6" OF TOPP OF WALL w/ 50" OVERLAPPING ® SPLICE POINT54 #4 VERTICAL B)AR5 ® 48" O.G. w/ 6" EMBEDMENT r.: PROVIDE CATCH BA51N PIPED TO DRYWELL INTO FOOTING. w/12"x24" CONTINUOUS FOOTING TO BE 3'-0" BELOW GRADE MINIMUM w/ (2) #5 REBAR5 CONTINUOUS; 5/e" (5ALV. ANCHOR BOLTS ® 48" O.G. SEAM SEAL, COPPER FL45 4)N6 BETWEEN FOUNDATION 4 (1) 2x6 ACQ. SILL PLATE 4 (1) D. FIR 2x6 SILL PLATE; TUFF 4 DRY WATER PROOFING ON NEW FND. WALL; TOP OF WALL TO ALIGN w/ EXIST. ADJACENT k;t DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 P. 6 31.2 71.5 4 0 0 WWW.DDANY.NET CROSS SECT I ON Copyright ©2025 All Rights Reserved. SEAL: PROJECT NORTH: 2x8 R.R. PROJECT IL : G.J. (5EE FRAMING PLAN FOR SIZE) SIMPSON' H3 HURRICANE TIE RENOVATIONS & ALTERATIONS TO THE: 2x6 TOP PLATE o----- -------------- M c NE ILL RESIDENCE 0 I�L"211 O 710 OLD MENHADEN ROAD CUTCHOGUE , NEW YORK 11935 DRAWING TITLE: GROSS SECTION MODIFIED BIRDS MOUTH DETAIL J DRAWN BY: SDE SHEET N0. 51RI7�5 MOU7H 1:)r=7AlL CHECKED BY: 5,J5 A300 I" = I'-O" (TYPICAL FOR 2x6 FRAMED WALLS) DATE: 10.20.25 ®3 00 SCALE: A5 NOTED PROJECT N0. 2515 r.. JACK 5TUD5 ® WINDOWS 4 OPTION FOR: DOORS AND/OR ® ENDS ° BLOCKIN6 ® 24" O.G. or OF SE6MENTED SHEARWALL THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY SOLID 2x FULL HEIGHT E D11ALL AS SPECIFIED ON PLANS THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE,AND ARE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER HOLOOWN ANCHOR ® ALL CORNER 5TUD CONNECTED TO ;'`�� LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE TRANSFER SHEAR HOEDOWN ANCHOR ; ; i ' ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL CORNER POSTS 5IMP50N HTT22 ; I i COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. 5IMP50N HTT22 IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION 2-16d COMMON NAILS ' OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I 6" O.G. 4 10" O.G. IF ;='" ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING BLOCKED CORNER POST —'—"1.==� _L _;: ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION'ALTERED BY' —"'" FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION ° LAW ARTICLE 147-ARCHITECTURE,SECTION 7307) THREADED ROD " THREADED ROD ISSUANCE: '; I STRUGTURL RIDGE RIDGE NO. DATE: DESCRIPTION: BLOGKIN6 ® ENDWALL5 5IMP50N 5TRON6 TIE SIMPSON STRONG TIE ;; "'"""- 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING CATHEDRAL CEILIN65 LRU28 - 2"X6" X 10" OR 20XI2" WITH COLLAR TIES AT 52" O.G. ® 04.09.26 =0 PLR OWNER CHANGES STUD TO TOP PLATE PROVIDE (FACE) (10) IOD X U'2" NAILS 05-20 X 18" MIN. ® 16" O.G. WITH () IOD ADD BASEMENT EGRESS STAIR PROVIDE (JO15T)(10) 5D X I XY NAILS COMMON NAIL PER RAFTER INSTTALLED 51MP50N STRONG TIE H8 ® I6" O.G. OVER PLYWOOD , W/ (5) IOD X I )Y EACH END C5-20 X IS" MIN. WITH (7) IOD COMMON NAIL PER RAFTER INSTALLED OVER PLYWOOD • • SECOND FLOOR Li U. -O ATTAOHMENT POINT 00 JACK 5TUD5 ® WINDOWS 4 DOORS AND/OR ® ENDS OPTION FOR: OF SEGMENTED 5HEARWALL BLOGKIN6 ® 24" O.G. or AS SPECIFIED ON PLANS SOLID 2x FULL HEIGHT ENDW,gLL HOLDOWN ANCHOR 5IMP50N HTT5 Ls-ro • I I I MT516 CORNER STUD CONNECTED TO HOEDOWN ANCHOR ® ALL TRANSFER SHEAR CORNER POSTS ' 5IMP50N HTT5 ' LFTA 2-Ibd COMMON NAILS ® ; 6" O.G. t 10" O.G. IF BLOCKED CORNER P05T ADJUSTABLE HANGER ADJUSTABLE HANGER ALL THREADED ROD ° ALL THREADED ROD 5IMP50N 5TRON6 TIE 5IMP50N 5TRON6 TIE " L570 PROVIDE (10) IOD i YY NAILS L55U28 - 2 XS , 2 XIO AND 2 X12 5IMP50N GNW COUPLER --'' PROVIDE (FACE) (10) IOD X VY NAILS 5IMP50N GNW COUPLER PROVIDE (JO15T)(10) IOD X 1 Y2" NAILS BLOCKING ® ENDWALIS CLEAR ; 5IMP50N 5ST13 SPAN ANCHOR BOLT 5IMP50N 55TB o. ANCHOR BOLT , STUD TO STUD CONNECT I ON5 FIRST FLOOR 5IMP50N 5TRON6 TIE LFTA ® 116" O.G. MIN. ° ` ATTACHMENT POINT (PROVIDE (8) IOD I Y2 NAILS E/4GH END OR (2) 12 STRUCTURAL KUROS SORBI-AVA ENGINEERING a " ENGINEER: 169 COMMACK ROAD MT516 ® 16" O.G. MIN. (PROVIDE (1) IOD X I Y2" NAILS "`"� SUITE H-362 AT EACH END OR "05" COIL 5TRAP FLOOR TO COMMACK, NY 11725 FLOOR BAND WFCM TABLE 5 31B INSTALLED AT 16" 631-355-5556 O.G. (4) IOD " NAILS EACH EIND OD STRAP. 31-35 I Y2 47 A E A R IIIIIIN A L L AI D 7'rf= I CAL 1=L00R40 F, 0 L 7f=IRAM I N6 SETA I L A 1 5 N 4 1 x a, 3 HURRICANE CLIP HIP CORNER PLATE SIMPSON STRONG TIE H8 ® 16" O.G. SIMPSON STRONG TIE (HGP) A��\A L " W/ (5) IOD X I Y2 EACH END HGP - 2X MEMBER SIZE INSTALLATION OVER PLYWOOD 15 HGP - 4X MEMBER / L/3 L/3 ACCEPTABLE A5 PER MIN. NAIL PROVIDE (6) IOD X I YY TO RAFTER PENETRATION (G-2003 PG.II) 015,1 1 PROVIDE (6) IOD X I Y2" TO PLANES / D14 MAX. XX OR SIMPSON STRONG TIE (MT512) 2N Q Q NO NOTCHES PERMITTED D/3 AX ` a ' PROVIDE (7) IOD X I ' TO RAFTER Y2 A PROVIDE (7) 100 X I YY TO PLAITES p DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. 74YOF I CAL I 1:)6r= / RA1=7r=R 255 MAIN STREET SUITE 200 HU ON, NY 11743 RP. 631.271 .5400 WWW.DDANY.NET Copyright 02025 All Rights Reserved.erved. 4O 57RAFFIN6 �E Try 1 L S ' - '' CANTILEVERED PORTION R.R. N FOR MEMBERS LE55 THAN 4 IN. SEAL: PROJECT NORTH: NOMINAL DIMENSION . DEPTH OF TAPER FLOOR JOIST— CENTER GUTS y CUT D/4 MAX. I MEASURE AT INSIDE FACE OF L r SUPPORT J015t DEPTH TAPER GUT PROJECT TITLE: NO NOTCHE5 PERMITTED GS Q 0 RENOVATIONS & ALTERATIONS TO THE: LBP5 McNEILL RESIDENCE D/4 MAX. Vir GE I L I NG JOIST TAPER OUT 710 OLD MENHADEN ROAD IZ o.c. �= FOR MEMBERS LE55 THAN 4 IN. CUTCHOGUE NEW YORK 11935 YY 0 LAG Ibrr 51MP50N NOMINAL DIMENSION DRAWING TITLE: 51MP50N U210 U26 , H6R. ® 16" PROVIDE 146R. ® I6" 5/8" C ANCHOR BOLT FLOOR JO 1ST— END GUTS STRAPP I NCB DETAILS Io 10D 1 Y2" �1Ls PROVI YY IDE 10 IOD e ® 23" O.C. GUTTING, NOTCHING, DRILLING PROVIDE 5/8 X 12 ANCHOR B(OLT5. ALL — — — FOUNDATION Y4ALL5 SHALL HA\VE ANCHOR BOLTS I I FOR COLUMN TO GIRDER SET APPROXIMATELY ONE FOOT FROM EACH — — — CONNECTION SEE ADJACENT D/3 MAX. FRAMING DETAILS CORNER AND 6 TO 12 FROM EACH END, SPACED = — 23" ON GENTEIZ. THERE SHALL BE ANCHOR BOLTS DETAIL ON EITHER SIDE OF ANY OPENING AND AT LEAST TWO BOLTS IN ANY ONE SILL. PORCH/I7EGfC/HOUSE PORG�'—f/GIRDER C< 1:)N lECTII <2N DETA1L FLOOR Mf SONRY/ CONCRETE CONNECTIONS GO1�l1�lE=GT 101�t DF—TA I L 2" MIN. FROM TOP 4 DRAWN BY: 5DE SHEET NO. 5IMP50N 5TRON6 TIE 5/8" DIA. LBP5 WITH 3"x3" BEARING BOT. OF JOIST PLATE ® 23" o.c. AND G5 016" O.G. (FILL ALL NAIL HOLES CHECKED BY: 5JS Pi/ 80 X I V NAILS) TO RUN UNDER SILL PLATE AND WRAP D (ACTUAL DEPTH) UP AND OVER SILL PLATE GUTTING NOTCH I N6 4 DRILLING DATE: 10.20.25 -4 SCALE: A5 NOTED 2 7"YOF I GALf=0UN1*.�)A71 Oilr5`-N7%rofz . AEGf=RAM I NO SET I L15 CU771N6 , NOTCHING =�RILLIN6 1;)E7A1L5Im = 1'-0" PROJECT No. 2515 —40 AMI I'fit 6 �ETAI L III = 1'-0" 40 40 v s , 777 I � ` JV THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY P.S.F. VALUES TO BE USED IN SELEGTIN6 ALL EXTERIOR THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECTS SERVICE,AND ARE AND SHALL MATERIALS FOR ROOFS SIDEWALLS NA / �/ G I I 1 I REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE /,/ ✓/ O; (RESIDENTIAL GODS OF NEW YORK STATE) I ( N G S G U L. l /� O ✓U > INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE 2 EFFECTIVE BASIC, W EFFECTIVE WIND SPEED BASIC, WIND SPEED ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL y_ ' /% / ✓ i RppF RppF COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. AA,�/ WIND AREA IIo 12o PITCH zO w1NO AREA IIo Ito NUMBER OF NUMBER OF t � 2 / /, y / / (90' FTC �� (90' FT) JOINT DESCRIPTION COMMON NAIL BOX NAILS NAIL SPAG I NG IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION �_ OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL IIN I 10 10.0 -21.8 105 -25A I 10 la.a -21.8 23.? -25A ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION"ALTERED BY' /" �✓ / / / R R A N1 I N FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE 000 / r / / / I 20 10.0 -21 2 10.0 -25 2 I 20 1a.4 -20.1 23.0 -24.6 SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION /' / / _ ' / / -� -' I RAFTER TO TOP PLATE (TOE-NAILED) 3 - ad 3 - IOd PER RAFTER LAW ARTICLE 147 ARCHITECTURE,SECTION 7307) �•' ��� � / � S /���'`� � �� / / �' � � I s0 10.0 -205 10.0 -24.4 I 50 18.6 -Ia2 222 -22.8 ISSUANCE: l / I J 1 100 10.0 -la.a 10.0 -23.1 ry-� 1 100 18.1 -16.1 21 B -215 GE I L I NG JOIST TO TOP PLATE (TOE-NAILED) 3 - ad 3 - loci PER JO 1ST NO. DATE: DESCRIPTION: 2 10 10.0 -565 105 -45 ry 2 Io la.a -255 23.1 -3 5 03 CEILING JOIST TO PARALLEL RAFTER (FACE-NAILED) (HEEL JOINT) 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING RAFTER SLOPE: 5:12 22 - Ibd 22 - 40d - 2 20 10.0 32.6 10.0 -38.8 ry ° 2 20 1a.4 -24.3 25.0 -2a.0 •g,� �-� � �/vi / � � � ���� O� tom- tQ 4:12 I-7 - Ibd 1'7 - 40d 04.09.26 ADD BASEMENT EGRESS STAIR 2 so 10.0 -2-75 10.0 -32.1 2 50 15.6 -22A 22.2 -2" 2 5:12 to - Ibd 10 - 40d EACH LAP 2 100 10.0 -23b 10.0 -26.1 2 loo 15.1 -21.8 215 -25A cl:12 AND GREATER S - Ibd b - 40d y INTERIOR ZONE 3 10 10.0 -55.0 105 -65.4 3 10 Ia.a -255 23.? -BOB CEILING JOIST LAPS OVER PARTITION (PAGE-NAILED) _ RAFTER SLOPE: 3:12 22 - Ibd 22 - 40d 3 20 10.0 -455 10.0 542 3 20 Ia.4 -24.3 23.0 -2a.0 ® PERIMETER ZONE 4:12 1-7 - Ibd 1-7 - 40d NOTE: 3 50 10.0 -55.1 10.0 -3a.3 3 50 15.6 -22A 22.2 -27.2 5:12 14 - Ibd 14 - 40d EACH LAP I. FOR &ABLE ROOFS loit TO 456 PITCHES -1:12 10 - Ibd 10 - 40d 3 100 10.0 -23b 10.0 -28.1 3 100 18.1 -21.8 215 -25.a q:12 AND GREATER 8 - Ibd b - 40d 2. SEE FASTENING SCHEDULE A FOR NAILING IN EA. ZONE 1 10 125 -la.a 14A -23.1 4 10 21.8 -25.6 25A -2aJ COLLAR TIE TO RAFTER (FACE-NAILED) 3. AN EDGE INDICATES THE EDGE OF EA. PANEL :12 1 - IOd 7 - 12d 3 RAFTER SLOPE: A FIELD INDICATES THE FIELD OF EA. PANEL 1 20 11.4 -1a.4 15.6 -25.0 4 20 20.8 -22.6 24.'1 -26.a 5:12 I 5o 10.0 -18.6 IIA -2222 4 50 lay -21B 252 -25.4 5:12 4 - IOd 4 - 12d PER TIE 6:12 AND GREATER 4 - 10d 4 - 12d 1 100 10.0 -16.1 105 -21.5 J 4 100 185 -20A 22.0 -24.2 2 10 125 -42.1 14A -50.1 s 10 21.5 -2411.1 25A -54.1 BLOGKING TO RAFTER (TOE-NAILED) 2 - ad 2 - 10d EACH END � O '0000_ O /, ; / / N O 2 20 11.4 -382 15.6 -45.4 s 20 208 -2"12 24."I -32.4 RIM BOARD TO RAFTER (END-NAILED) 2 - Ibd 3 - 16d EACH END 2 50 10.0 -55.0 I I A -3a.3 5 50 IaS -24.6 25.2 -2a.3 F R A M I N D 2 / '/~ %�./ _ �!` / / / 2 100 10.0 -2a.1 105 -34.7 5 100 15.5 -22.6 22.0 -26A �� Al :: / 1 / %],�J 3 10 125 -42.1 14.a -50.1 FOR SI: 1 Fool = 304.8 ,,, 1 sa. FT. = o.oa2a Sa. METERS, TOP PLATE TO TOP PLATE (PAGE-NAILED) 2 -Ibd I 2 16d 1 PER FOOT I T �/ 2 / , \I / j I MPH = I bOa KM/H � \ i � / 7 / 3 20 11.4 -382 15.6 -45.4 TOP PLATES AT INTERSECTIONS (PAGE-NAILED) 4 - Ibd 5 - Ibd JOINTS -EACH SIDE g 2 _ j / / r J NOTES: FOR EFFECTIVE WIND AREAS BETWEEN THOSE GIVEN ABOVE THE LOAD MAY BE INTERPOLATED;OTHERWISE USE so lo.o -33.0 11.a -3a3 THE LOAD ASSOCIATED WITH THE LOMR EFFEcnVE AREA. STUD TO STUD (FACE-NAILED) 2 -Ibd 2 - Ibd 24" O.G. TABLE VALUES SHALL BE ADJUSTED FOR HEI6HT AND EXPOSURE 4 100 10.0 -2a.1 105 -34.? BY MULTIPLYING BY THE ADJUSTMENT COEFFICIENT IN TABLE Lil R3012(3). SEE FIGURE R3012(8) FOR LOCATION of ZONES. HEADER TO HEADER (FACE-NAILED) Ibd Ibd 16" OG ALONG EDGES PLUS AND MINUS 516NS SIGNIFY PRESSURE ACTING TOWARD AND / AWAY FROM THE BUILDING SURFACES. TOP OR BOTTOM PLATE TO STUD (END NAILED) 2 - Ibd 2 - 40d PER STUD INTERIOR ZONE BOTTOM PLATE TO FLOOR JOIST, BANDJOIST, ENDJO15T OR BLOGKIN 2 - Ibd 1,2 2 - Ibd 1,2 PER FOOT (FACE-NAILED) fig' k. PERIMETER ZONE I FRE55URE ZONE5 STRUCTURAL KUROS SORBI-AVA ENGINEERING ENGINEER: 169 COMMACK ROAD L.. ��I F L_ O O R F R M ( O SUITE H-362 I. FOR HIPPED ROOFS 10� TO 45%b PITCHES COMMACK, NY 11725 2. SEE FASTENING SCHEDULE A FOR JOIST TO SILL, TOP PLATE OR GIRDER (TOE-NAILED) 4 -ad 4 - loci JOIST 631-355-5556 NAILING IN EA. ZONE 3. AN EDGE INDICATES THE EDGE OF EA. PANEL BRIDGING TO JOIST (TOE-NAILED) 2 - ad 2 - 10d EACH END A FIELD INDICATES THE FIELD OF EA. PANEL BLOCKING TO JOIST (TOE-NAILED) 2 - ad 2 - 10d EACH END 1�1A I L 11�1G 1�lOTs WINDBORNE DEBRIS PROTECTION FASTENING BLOGKING TO SILL OR TOP PLATE (TOE-NAILED) 3 - Ibd 4 - 16d EACH BLOCK x . SCHEDULE FOR VgOOD STRUCTURAL PANELS I. NAILING REQU I REMENTS ARE BASED ON WALL SHEATHING NAILED 6" ON GENTER AT THE PANEL EDGE. IF LEDGER STRIP TO BEAM (FACE-NAILED) 3 - 16d 4 - Ibd EACH JOIST k [REFER TO TABLE R301.2.1.2 OF THE RESIDENTIAL GORE OF° NEW YORK STATEI WALL SHEATHING 15 NAILED 5" ON CENTER AT THE PANEL EDGE TO OBTAIN HIGHER SHEAR GAPAG I TI ES FASTEN ERPAGI NG INCHES JOIST ON LEDGER To BEAM (TOE-NAILED) 3 - ad 3 - loci PER JO I ST NAILING REQU I REMENTS FOR STRUGTURAL MEMBERS SHALL BE DOUBLED OR ALTERNATE GONNEGTORS FASTENER TYPE PANEL SPAN 4 FFEET < b FEET < SUCH AS SHEAR PLATES, SHALL BE USED < 4 FEET PANEL SPAN PANEL SPAN BAND JOIST TO JOIST (END-NAILED) 3 - ibd 4 - Ibd PER JOIST TO MAINTAIN THE LOAD PATH. <_b FEET < 8 FJ3=T No. 8 WOOD SGREw BASED ANCHOR w/2" I6 10 8 BAND JOIST TO SILL OR TOP PLATE (TOE-NAILED) 2 - Ibd 2 - Ibd PER FOOT ' ' 2. WHEN PgALL SHEATHING 15 GONTI NUOUS OVER GONNECTED MEMBERS, THE TABULATED NUMBER OF NAILS EMBEDMENT LENGTH SHALL BE PERMITTED TO BE REDUGED TO I - I6d PER FOOT. "EMBmt�T�6STHW BASED ANCHOR w/2" I6 12 a ° R O CD F S H E= A T i-t I N G 3. CORROSION RESISTANT 11 GAGE ROOFING NAILS AND 16 GAGE STAPLES ARE PERMITTED; GHEGK I BG FOR Y44" LA 1 CIE H BASED ANCHOR w/2" 16 16 Ile? ADDITIONAL REQUIREMENTS. STRUCTURAL PANELS: PANEL INTERMEDIATE DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. ED6E5 SUPPORTS 4. ALL QUANTITIES ARE BASED ON 16'� OG SPAG I NG FOR RAFTERS, JOISTS AND STUDS. MINIMUM UNIFORMLY DISTRIBUTED DES I�N LOADS P.56 3 M 2 7N.5 4 0 0 STREET SUITE 200 H U N T I N G T 0�DDANY.NE7 INTERIOR ZONES 6d lod Copyright ©2025 AIIRightsReserved. [REFER TO TABLE R301S OF THE RESIDENTIAL GORE OF NEWT PORK STATE-1 4 6 5. FOR ROOF SHEATHIING WITHIN 4 FEET OF THE PERIMETER EDGE OF THE ROOF, INGLUDING 4 FEET ON EAGH PERIMETER EDGE ZONE 8d lod 41 1 Orr SEAL: PROJECT NORTH: SIDE OF THE ROOF PEAK, THE 4 FOOT PERIMETER EDGE ZONE ATTAGHMENT REQUIREMENTS SHALL BE USE 1[LIVE LOAD , DEAD LOAD USED. EXTERIOR BALCONIE54VECK5 40 psf 10 psf GABLE ENDWALL RAKE WITH LOOKOUT BLOCK ad IOd 4" 4" b. FOR WALL SHEATHE 1 NG WITHIN 4 FEET OF THE CORNERS, THE 4 FOOT EDGE ZONES ATTACHMENT ATTICS WITHOUT STORAGE(ROOF BELOW 5 PITCH) 10 psf 10 psf G E= I L_ I N S 1-4 E= A -F H I N � REQUIREMENTS SHALL BE USED. ATTICS WITH STORAGE (ROOF ABOVE 3 PITCH) 20 psf 10 psf GYPSUM WALLBOARD 5d COOLERS 5d COOLERS 7" EDGE / 10" FIELD ROOMS OTHER THAN SLEEPING ROOMS 40 psf 10 psf SLEEPING ROOMS 30 psf 10 psf A L �-- A T I N O NOTE: STAIRS 40 psf 10 psf STRUCTURAL PANELS/HARDBOARD PANEL INTERMEDIA PROJECT TITLE:ALL STRAPPING TO BE 1,4"x20 G EDGES SUPPORTS GAUGE STEEL OR 'SIMPSON' EQUIVALENT GUARDRAILS AND HANDRAILS 200 psf to psf RENOVATIONS & ALTERATIONS TO THE: - 0520 (COILED STRAP) INTERIOR ZON05 Sd lod 6" 6" (ALL STRAPPING SHALL BE INSTALLED PRIOR TO SHEATHI NGZ 4' EDGE ZONE b Sd lod M c N E I LL RESIDENCE NOTATION: MINIMUM ROOF LIVE LOADS 6" b" A- NUMBER OF 8d NAILS ® EA. END OF STRAPPING (TABLE 3.1, P. 151) [REFER TO TABLE R301S OF THE RESIDENTIAL CODE OF NEJW YORK STATEI FIBERBOARD PANELS: A D B- NUMBER OF SILL STUDS-ON FLAT(DOES NOT APPLY TO DOORS) (TABLE 323B, P. la3) TRIBUTAFZY LOADED 7/16" bd3 - 3" EDGE / 6" FIELD 710 OLD MENHADEN ROAD G- NUMBER OF FULL HEIGHT KING STUDS ROOF SLOPE AREA IN 5.17. FOR ANY 25/32" ads - 3" EDGE / 6" FIELD ® EA. SIDE OF HEADER (TABLE 3.230, P. Ia3) STRUGTUR:AL MEMBER CUTCHOGUE , NEW YORK 11935 D- NUMBER OF Ibd NAILS, END-NAILED THROUGH ADJACENT KIN& STUD C To END OF HEADER ® EA. SIDE (TABLE 3.-1, P. vt) GYPSUM WALLBOARD 5d COOLERS 5d COOLERS 7" EDGE / 10" FIELD DRAWING TITLE: JACK STUDS ® EA. END OF HEADER F- NUMBER OF Ibd NAILS, END-NAILED THROU6H ADJACE I) NT JACK STUD O TO 200 OI TKO 6 OVER 600 1�1A I L I NG SGHEDULE TO END OF SILL(S) ® EA. SIDE (DOES NOT APPLY TO DOORS) (TABLE 5.8, P. 157) FLAT OR RISE LESS THAN 4 INCHES 20 16 12 PARTICLE BOARD PANELS ad ad SEE MANUFACTURER B PER FOOT(I=3) FASTENING SCHEDULE B RISE 4 INCHES PER FOOT (1:3) TO LESS Ib 144 12 ROUGH OPENIN6 FRAMING REQUIREMENTS FOR WINDO"OOR OPENINGS THAN 12 INCHES PER FOOT(1:1) F= L- O O R S A T �--I 1 N C'7 RISE 12 INCHES PER FOOT(I:1) AND [IN ACCORDANCE WITH�QQJ�4 1�. 12 I;2 12 CONSTRUCTION MANUAL 2015 EDITIONI CATER STRUCTURAL PANELS: F I" OR LESS 8d lod 6" EDGE / 12" FIELD ROUGH NOTATION G E F NOTATION ALLOWABLE DEFLECTION OF STRUCTURAL MEMBERS GREATER THAN I" IOloci16d 6" EDGE / 6" FIELD A D OPN& [REFER TO TABLE R301.1 OF THE RESIDENTIAL CODE OF MJEW YORK STATE DRAWN BY: SDE SHEET N0. 21-0" 2 (U 2x4 I I I I STRUCTURAL MEMBER ALLOWABLE DEFLECTION 4'-0" 4 (1) 2x4 2 2 2 2 RAFTERS HAVING SLOPES GREATER THAN °.(� �� CHECKED BY: 5.15 WITH NO GEILIN6 ATTACHED TO GEILIN6 61 -0" 6 (2) 2x4 OR (1) 2x6 3 3 3 3 INTERIOR WALLS AND PARTITIONS HADO DATE: 10.20.25 W401 8'-O" 8 (2) 2x4 OR (1) 2x6 3 3 3 3 FLOORS AND PLASTER CEILINGS L/360 SCALE: AS NOTED 1 o'-O" 10 (2) 2xb 4 4 4 4 ALL OTHER STRUCTURAL MEMBERS L/240 PROJECT N0. 2515 12'-O" 12 (2) 2x6 5 5 5 5 EXTERIOR WALL-WIND LOADS WITH FLEXIBLE FINISHES LA20 :i%'' :.;h','a,'�t: '�i,?it�'?;;;��';* .?�, :irs`.:+. ."k�,- r`,.;': - w�."H,,; ,4'`3:.:i« •y{,;.:t. z I THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE,AND ARE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION ELECTRICAL LEGEND OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING "Z" = FIXTURE DE516NATION - SEE FIXTURE TYPE BELOW ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION'ALTERED BY' a a = CIRCUIT DESIGNATION FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION � DUPLEX RECEPTACLE - WP INDICATES WATER PROOF LAW ARTICLE 147-ARCHITECTURE,SECTION 7307) GFI DUPLEX RECEPTACLE WATER RE515TANCE GFI ISSUANCE: QUAD RECEPTACLE NO. DATE: DESCRIPTION: _u TV (GABLE) CONNECTION 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING $ SINGLE POLE SWITCH "DECORA TYPE" LUI PIER OWNER CHANGES ® 04.09.26 ADO BASEMENT EGRESS STAIR SINGLE POLE DIMMER SWITCH "DECORA TYPE" $3 3-WAY SWITCH "DECORA TYPE-- 4-HAY 5WITGH "DECORA TYPE-- JAMB 5WITGH SINGLE POLE 5WITGH W/ INDICATOR LIGHT "DECORA" EX EXISTING LIGHT FIXTURE/ 5WITGH/ RECEPTACLE TO REMAIN PROVIDE JUNCTION BOX FOR OWNER PROVIDED A CEILING FAN 001F INDICATED MEANS W/ LIGHT B -�- 5" CEILING RECESSED LEAVE TAIL FOR Cam- \ FUTURE G 4"CEILING RECESSED RELOCATION / \ D 40 4"CEILING RECESSED w/EYEBALL i / \\ DN. � E � OWNER PROVIDED WALL MOUNTED SCONCE db GFI ® 42" A.F.F. ' I/ / G --�- G� G 5D G F 0 OWNER PROVIDED VANITY WALL MOUNTED LIGHT GFI ' ' NEW J JUNCTION BOX FOR OWNER PROVIDED HANGING FIXTURE GFI ® 42" 1 ' I i_ K_ i EAT-IN � � � \ A.F.F. l i \\ i (:] i AREA \1 / HOME OFFICE EXIST. H 4- 4" RECESSED w/ SHOWER LENSE i PORCH I OWNER PROVIDED EXTERIOR WALL MOUNTED LIGHT GOO INA 5 ITCH / i / K OWNER PROVIDED CHANDELIER LO A 10 w 0 NERy i I � I J O -J G I / I G J 1 C G \ C I mp INDICATES MOTOR POWERED LOWERING DEVICE - WIRED TO SEPARATE 5WITGH K�i \ G I ® 42" 8 � / r K Q OWNER SELECTED HANGING PENDANT LIGHT A F.F. 1 ' Q � \ 1 // r- 1 l — L F—� UNDER CABINET LED LIGHT �i i I i 'I / G 1 RENOVATED \ -- --- EX EX 114 Ft. LED STRIP LIGHT W/ COVER — ��i J7 \ KITCHEN �I N6 O. G - ��_G�\ �� �` DINING ROOM - _ -NE-Pi - �=--___ - ' - _ - N CEILING MOUNTED PORCELAIN FIXTURE STRUCTURAL KUROS SORBI-AVA ENGINEERING -NEW LAUNDRY J / / FI ® 42 -_ ENGINEER: 169 SOMMUITE H 362CK 0AD - / A--- w _` 0 CABINET LIGHT COMMACK, NY 11725 - ------ -------- -T- L------ _I _- _ 631-355-5556 EX" � P ------ UNDER CABINET LED TAPE LIGHTING 1qpI \ EX¢ �i . . ONNERET Q OWNER PROVIDED ARTWORK LIGHTING l� - w X a, � 5D G � OWNER PROVIDED SURFACE MOUNTED LIGHT I C RELOCATED SD =i-PAH(0-54#1 LIGHT FIXTUREEX 5 OWNER PROVIDED LED LIGHT BAR WITH COVER A.NEW DEN EX / TOILET EXHAUST FAN CONNECTED TO LIGHT 5WITGH / \ EX =___ (It) IF INDICATED MEANS WITH LIGHT (t) MEANS TIMER ` \` t6a n {.3 z , Y - 42" EX NOTE: l EXIST. EX A.F.F. PROVIDE DIMMERS ON ALL SWITCHES WHENEVER P0551BLE O5. r-- -- ; " 9 y EX ' - ' EX - --- --- , DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. a255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 -- --- EXISTING FOYER EXIST. P. 631.271 .5400 I I LIVING ROOM cep�ionc 02025 All Rights Reserved. --- ---- EX0 I I SEAL: PROJECT NORTH: -- --- UTILITY NOTES: I. THE HVAG CONTRACTOR SHALL VERIFY THE 517E AND PERFORMANCE OF THE EXISTING 5Y5TEM(5) AND CALCULATE THE NEW REQUIREMENTS TO DETERMINE IF THE EXISTING M - - / DN. 5Y5TEM(5) WILL BE ADEQUATE TO ACCOMMODATE THE NEW EX EX ADDITION. IF THE 5Y5TEM(S) ARE NOT ADEQUATE, THE /EX GENERAL CONTRACTOR SHALL INCLUDE IN HI5 BID THE COST \ 0 OF EXPANDING THE 5Y5TEM(5) AS REQUIRED FOR PROPER \ I PERFORMANCE. NEH I\ GARAGE `I I 2. THE PLUMBING CONTRACTOR TO VERIFY THE 51ZE OF IRELOGATED \ I EXISTING DOMESTIC HOT WATER SYSTEM AND DETERMINE IF PROJECT TITLE: \ PORCH THE EXISTING SYSTEM WILL BE ADEQUATE FOR THE NEW AND RENOVATIONS & ALTERATIONS TO THE: GARAGE DOOR / / EXISTING LOADS COMBINED. IF SYSTEM 15 NOT ADEQUATE, THE GENERAL CONTRACTOR SHALL INCLUDE IN HIS BID THE OPENER ; COST OF EXPANDING THE SYSTEM AS REQUIRED FOR PROPER PERFORMANCE. M c N E I LL RESIDENCE 3. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE 51ZE OF I I THE EXISTING ELECTRIC SERVICE FOR ADEQUACY IN I 1 a a a a PROVIDING NEW ELECTRICAL INSTALLATIONS AS 5HOWN. 710 OLD MENHADEN ROAD M UPGRADE SERVICE, METER, PANEL, ETC. AS REQUIRED. ALL CUTCHOGUE , NEW YORK 11935 I ELECTRICAL WORK TO BE FIRE UNDERWRITER5 INSPECTED DRAWING TITLE: i I AND APPROVED. SUBMIT CERTIFICATE TO OWNER UPON I I RECEIPT. THE GENERAL CONTRACTOR SHALL INCLUDE IN HIS 1ST FLOOR LIGHTING 4 I I BID THE COST FOR THE UPGRADE AND ALL RELATED I i ELECTRICAL REQUIREMENTS. ELECTRICAL PLAN I 1 / ELECTRICAL NOTE: / PROVIDE ALL ELECTRICAL OUTL.ET5, 5WITCHE5, ETC. ACCORDING TO ALL STATE AND LOCAL CODES. 1 \ , COORDINATE WITH OWNER, LOCATIONS OF ALL ADDITIONAL - - SWITCHING, OUTLET5 AND LIGHTING. I- PROVIDE ELECTRICAL CONVENIENCE RECEPTACLE OUTLETS PER E3901. COORDINATE WITH OWNER DRAWN BY: 50E SHEET NO. ADDITIONAL REQUIREMENTS. 2- PROVIDE CONVENIENCE RECEPTACLE OUTLET IN CHECKED BY: SJ5 GARAGE, PER E3CIOI A WITH GFGI, PER E3C102.2 DATE: 10.20.25 1 ®1 0 3- PROVIDE ONE WALL 5WITGH CONTROLLED LIGHTING ON 1 �� FLAN NOTE: NOTE: THE EXTERIOR SIDE OF EACH OUTDOOR EGRESS DOOR SCALE: AS NOTED � I ST �LOO LIGHTING 4 ELEGT I /!(,� ELECTRICAL CONTRACTOR TO REVIEW LIGHTINGHAYING GRADE LEVEL ACCESS IN AC,(' WITH AND SWITCHING ELECTRICAL CONTRACTOR TO COORDINATE ANY ADDITIONAL E3a03.3 E 1 QO 1/4" = 1'-0" LAYOUT WITH CLIENT IN FIELD PRIOR TO INSTALLATIOM EXTERIOR LIGHTING REQUIREMENTS WITH OWNER PROJECT NO. 2515 4- GFGI's ARE TO BE PROVIDED, PER E3C102 777 THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE,AND ARE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION ELECTRICAL LGND OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING "Z" = FIXTURE DESIGNATION - SEE FIXTURE TYPE BELOW ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION'ALTERED BY" a a = GIRGUIT DESIGNATION FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION LAW ARTICLE 147-ARCHITECTURE,SECTION 7307) DUPLEX RECEPTACLE - HP INDICATES WATER PROOF I �GFI DUPLEX RECEPTACLE WATER RESISTANCE GFI ISSUANCE: QUAD RECEPTACLE N0. DATE: DESCRIPTION: -® TV (GABLE) CONNECTION 1. 10.20.25 ISSUED FOR BUILDING DEPARTMENT FILING $ SINGLE POLE SWITCH "DECORA TYPE" ADD BASEMENT EGRESS STAIR ® 04.09.26 SINGLE POLE DIMMER SWITCH "DECORA TYPE" j $3 3-WAY 5WITGH "DECORA TYPE" $4 4-WAY 5WITGH "DEGORA TYPE" I $j JAMB SWITCH SINGLE POLE 5WITGH W/ INDICATOR LIGHT ,DECORA" EX EXISTING LIGHT FIXTURE/ 5WITGH/ RECEPTACLE TO REMAIN PROVIDE JUNCTION BOX FOR OWNER PROVIDED \, ! A GEILING FAN (It)IF INDICATED MEANS W/ LIGHT B -0- 5" CEILING RECESSED C ¢ 4"GEILING RECESSED TO BE ON MOISTURE 5WITGH D 40 4"GEILIN6 RECESSED w/EYEBALL I • E � OWNER PROVIDED WALL MOUNTED SCONCE EX 1'_ -_ _ Os • F OWNER PROVIDED VANITY WALL MOUNTED LIGHT EX I H� C 6 JO JUNCTION BOX FOR OWNER PROVIDED HANGING FIXTURE RENO• I H } 4" RECESSED w/ SHOWER LEN5E NEN EXIST. BATH BATH #5 I I I RENO• I OWNER PROVIDED EXTERIOR WALL MOUNTED LIGHT BEDROOM #3 BALCONY EX — T — T — OWNER PROVIDED CHANDELIER ' NEW C I G I /� J O (mp) INDICATES MOTOR POWERED LOWERING DEVICE WIRED TO SEPARATE SNITCH WALK-IN GLOS. I I H I RENO. . K OWNER SELECTED HANGING PENDANT LIGHT WA K-IN I EX = 5D GLOS•/ L F-- UNDER CABINET LED LIGHT G \ I 0 EX M 4 Ft. LED STRIP LIGHT W/ COVER EXP W_ Tl N � GEILING MOUNTED PORCELAIN FIXTURE STRUCTURAL KUROS SORBI-AVA ENGINEERING EX REND. ENGINEER: 169 COMMACK ROAD EX EX¢ 5D \ _B GD /—_— _ ` BEDROOM #I�h SUITE H-362 1 \\ / \ O CABINET LIGHT — B ' _ � COMMACK, NY 11725 631-355-5556 _ P ------ UNDER GA13INET LED TAPE LIGHTING ILI— — J/911 EQ. �EO O OWNER PROVIDED ARTWORK LIGHTING EXIST. HALL X J I i i . . \�H i EX SD EX¢ EW R O OWNER PROVIDED SURFACE MOUNTED LIGHT �\ \ BATH #4 2 F ,. .� OWNER PROVIDED LED LIGHT BAR WITH COVER " =.:.`:: — 1 i EX EX TOILET EXHAUST FAN CONNECTED TO LIGHT 5WITGH ;;;.. (It) IF INDICATED MEANS WITH LIGHT (t) MEANS TIMER El NEH --- -- �BEDROOM #4zc] _-- -- - _ PROVIDE DIMMERS ON ALL SWITCHES WHENEVER P0551BLE y" Cr --- -- EX \ _ I FLOOR RECEPTACLE _ EX ENO' ` I DIVERSIFIED DESIGN ASSOCIATES - ARCHITECTS, P.C. BEDROOM #2 I I 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 EX I P. 6 31.2 71.5400 WWW.DDANY.NET Copyright 02025 All Rights Reserved. SEAL: PROJECT NORTH: UTILITY E. THE HVA G 1 CONTRACTOR SHALL VERIFY THE SIZE AND I I I I PERFORMANCE OF THE EXISTING 5Y5TEM(5) AND CALCULATE EX THE NEW REOUIR -fENT5 TO DETERMINE IF THE EXISTING Q �n 5 I SY5TEM(5) WILL BE ADEQUATE TO ACCOMMODATE THE NEW ADDITION. IF THE 5Y5TEM(5) ARE NOT ADEQUATE, THE EX EX I GENERAL CONTRACTOR SHALL INCLUDE IN HIS BID THE COST OF EXPANDING THE 5Y5TEM(5) AS REQUIRED FOR PROPER PERFORMANCE. 2. THE PLUMBING CONTRACTOR TO VERIFY THE 51ZE OF EXISTING DOMESTIC HOT WATER SYSTEM AND DETERMINE IF PROJECT TITLE: THE EXISTING SYSTEM WILL BE ADEQUATE FOR THE NEW AND RENOVATIONS & ALTERATIONS TO THE: EXI5TIN6 LOADS COMBINED. IF 5Y5TEM 15 NOT ADEQUATE, THE GENERAL CONTRACTOR SHALL INCLUDE IN HI5 BID THE COST OF EXPANDING THE SYSTEM AS REQUIRED FOR PROPER M c NE I LL RESIDENCE PERFORMANGE. 3. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE 51ZE OF THE EXISTING ELECTRIC SERVICE FOR ADEQUACY IN 710 OLD MENHADEN ROAD PROVIDING NEW ELECTRICAL INSTALLATIONS AS SHOWN. CUTCHOGUE NEW YORK 11935 UPGRADE SERVICE, METER, PANEL, ETC. AS REQUIRED. ALL ELECTRICAL WORK TO BE FIRE UNDERWRITER5 INSPECTED AND APPROVED. SUBMIT CERTIFICATE TO OWNER UPON DRAWING TITLE: RECEIPT. THE GENERAL CONTRACTOR SHALL INCLUDE IN HI5 2ND FLOOR L I CGHTI NCB 4 [310 THE COST FOR THE ELECTRICAL REGUIREMEN 5RADE AND ALL RELATED ELECTRICAL PLAN ELECTRICAL NOTE: PROVIDE ALL ELECTRICAL OUTLETS, 5WITCHE5, ETC. ACGORDIN6 TO ALL STATE AND LOCAL CODES. COORDINATE WITH OWNER, LOCATIONS OF ALL ADDITIONAL SWITCHING, OUTLETS AND LIGHTING. I- PROVIDE ELECTRICAL CONVENIENCE RECEPTACLE OUTLETS PER E3a01. COORDINATE WITH OWNER DRAWN BY: 5DE SHEET NO. ADDITIONAL REOUIREMENT5. 2- PROVIDE CONVENIENCE RECEPTACLE OUTLET IN CHECKED BY: 5J5 1 GARAGE, PER E3401A WITH GFCI, PER E31102.2 DATE: 10.20.25 3- PROVIDE ONE WALL SWITCH CONTROLLED 1_16HTIN6 ON Eml 0 1 I BECCNIOoD f"LOOR L16H71N& 4 ELE07RICAL PLAN NOTE: NOTE: THE EXTERIOR SIDE OF EACH OUTDOOR EGRESS DOOR SCALE: A5 NOTED El ECTRIGAL CONTRACTOR TO REVIEW LI6HTINC6 AND 5WITGHIN6 ELECTRICAL CONTRACTOR TO COORDINATE ANY ADDITIONAL HAVING GRADE LEVEL ACCESS IN AC-CORDANGE WITH E101 1/4" = 1'-0"' LAYOUT WITH CLIENT IN FIELD PRIOR TO INSTALLATION EXTERIOR LIGHTING REOUIREMENT5 WITH OWNER E3a03.3 PROJECT NO. 2515 4- GFGI's ARE TO BE PROVIDED, PER E3L102 >. • a f 1Ale. D E C E I WE 2026AUG 3 DepartmentBuilding Town of Southold A� Home Comfort Group I9 BOSCH P A 1 4 2026 -.WNW Bosch 16S Light An inverter system at a price point you'll love! The first 15-SEER2 Inverter condenser solutionthe markety®BOSCH Futty-modutating inverter drive USCH 4 Sound levels aslow as 59 • ' condensing / air handlers • lo, System - / CompatiblefromIIIII IIIIIIIIIIIIlII!! 11II ��� IIIII IIIII POSCH IIIII lllli . • - • / -• standards ��r IIIII IIIlllfllllflllli fill ' IIII.Illlllllllllllll!'lllli ! ° technology0- Premium LOWGWP I o .. Bosch IDS Light Advanced Comfort Without the Premium Price The Bosch IDS Light delivers premium inverter performance and ENERGY STAR efficiency at an exceptional value. Designed for steady,quiet operation, it provides the comfort and reliability expected from the Bosch IDS lineup. The BOVB15 outdoor unit is available in 24K,36K, and 60K BTU capacities and uses lower-GWP R-454B refrigerant to meet today's environmental standards. It pairs seamlessly with Bosch BIVA ,compact BIWA, or BICA air handlers, allowing flexible system design for a wide range of applications. Integrated sound-dampening and smart thermostat compatibility help ensure consistent, quiet comfort. 15 SEER2 System 16 SEER2 System 16 SEER2 System IDS Light IDS Light Compact Wall IDS Light Compact Ceiling mom Mowee ,III IIIIIIIII11N1111IIII�I IIIIIIIIIIIIIIIIIIIIIIIIIIII iIIIIIIIIIIIIIIIIIIIIIIIII BICA16 illllllll ���IIIIIIIIII, .IIII IIIII `�NIIIIIII illlllllll Illilllll' .IIII IIIIIIIIIIIIIIIII IIII!i 'IIIII IIIIIIIIIIIIIIIII Illlli IIIIII Illlllllllllillli IIIL' illlllllllllllllllllll,IIIIII �Illlllillllllllllllllllllll, a IIIIIIIiIIIIIIINII!!IIIIII�, BIWA16 ► The first 15-SEER Inverter condenser ► A versatile wall-mounted air handler paired ► A compact ceiling-mounted air handler on the market. with an inverter condenser to create a space combined with an inverter condenser ► With IDS Light,you get the comfort of our saving comfort solution. to create a powerful combination. inverter system at a price point you'll love! ► This system combines the BOVB15 ► This system combines the BOVB15 outdoor unit with our BIWA16 constant outdoor unit with our BICA16 constant ► This system combines the standard torque air handler. torque air handler. efficiency BOVB15 outdoor unit with our BIVA15 fixed-speed air handler. P ea,,v€o to vwvv hosch homrcom(or!,,s rr,•f'.A,��m�;etl h'drrgnty a��ta`s 76�i9913043 System & Technical Information BOSCH IDS LIGHT DESCRIPTION DIMENSIONSD BOV015 OUTDOOR CONDENSING SECTION B0V8-24RTB-M15S 24 kBTU/hr(2 ton) 8733982681 28.00 24.938 28.000 BOVB-36RTB-M15S 36 kBTU/hr(3 ton) 8733982682 28.00 24.938 28.000 BOVB-60RTB-M15S 60 kBTU/hr(5 ton) 8733982683 29.125 33.188 29.125 INDOOR AIR HANDLER BIVA-24RXB-Ml5X 24 kBTU/hr(2 ton) 8733965419 19.625 46.5 21.625 I BIVA-36RXB-M15X 36 kBTU/hr(3 ton) 8733965420 19.625 46.5 21.625 BIVA-48RXB-M15X 48 kBTU/hr(4 ton) 8733965421 22.0 54.5 24.0 BIVA-60RXB-M15X 60 kBTU/hr(5 ton) 8733965422 22.0 54.5 24.0 INDOOR BIWA-18RXB-M16X 18 kBTU/hr(1.5 ton) 8733965439 20.5 36.5 15 BIWA-24RXB-M16X 24 kBTU/hr(2 ton) 8733965440 20.5 36.5 15 BIWA-30RXB-M16X 30 kBTU/hr(2.5 ton) 8733965441 22 39.5 19 BIWA-36RXB-M16X 36 kBTU/hr(3 ton) 8733965442 22 39.5 19 INDOOR , BICA-18RXB-M16X 18 kBTU/hr(1.5 ton) 8733965443 37.25 10.5625 26.3125 BICA-24RXB-M16X 24 kBTU/hr(2 ton) 8733965444 37.25 10.5625 26.3125 BICA-30RXB-M16X 30 kBTU/hr(2.5 ton) 8733965445 49.25 10.5625 26.3125 BICA-36RXB-M16X 36 kBTU/hr(3 ton) 8733965446 49.25 10.5625 26.3125 BMAC CASED COIL DIMENSIONS IDS PORTFOLIO PAIRING OUTDOOR UNIT(BOVB1S) MODEL -N U M-BE R -:RM l ✓IDS Plus BMAC2430ABTA 8733965423 14.5 20.0 21.0 13.375 15.625 20.5 System Combination BMAC24308BTA 8733965424 17.5 20.0 21.0 16.375 15.375 20.5 BMAC3036ABTA 8733965425 14.5 20.0 21.0 13.375 15.625 20.5 . ✓IDS Light System Combination BMAC3036BBTA 8733965426 17.5 20.0 21.0 16.375 15.375 20.5 BMAC3036CBTA 8733965427 21.0 20.0 21.0 19.875 15.25 20.5Cased Coit Only i SMAC4248BBTA 8733965428 17.5 30.0 21.0 16.375 26.88 21.0 • BMAC4248CBTA 8733965429 21.0 30.0 21.0 19.875 26.8 21.0 1 ✓ BMAC4248DBTA 8733965430 24.5 30.0 21.0 23.625 26.6 21.0 BMAC4860CBTA 8733965431 21.0 30.0 21.0 19.875 27.0 21.0 BMAC4860DBTA 8733965432 24.5 30.0 21.0 23.625 26.8 21.0 IDS Field Installed Electric Heat Kits IDS Communication Kit Bosch electric heat kits provide reliable auxiliary heating The IDS Communication Kit is required when pairing the Bosch to support heat pump operation in colder conditions. Low GWP Cased Coil with a 3rd party Furnace. COMMUNICATIONFIELD INSTALLED ELECTRIC HEAT KITS IDS DES H PART NUMBER DESCRIPTION •, �L , I • 8733983568 IDS Communication Kit EHK-05C 8733977739 5 kW Electric Strip Heater EHK-08C 8733977740 7.5 kW Electric Strip Heater EHK-10C 8733977741 10 kW Electric Strip Heater EHK-15C 8733977742 15 kW Electric Strip Heater EHK-20C 8733977743 20 kW Electric Strip Heater WALL MOUNTED FIELD INSTALLED ELECTRIC HEAT KITS EHK2-05B 8733980955 5kW EHK for LGWP BIWA AHU Bosch Home Comfort 0 y 0 EHK2-08B 8733980956 7.5kW EHK for LGWP BIWA AHU Product Catalog EHK2-10B 8733980957 10kW EHK for LGWP BIWA AHU Scan QR i