Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
45328-Z
SUFFo`z i TOWN OF SOUTHOLD BUILDING DEPARTMENT y TOWN CLERK'S OFFICE o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 45328 Date: 10/15/2020 Permission is hereby granted to: Schwamborn, Jason 2370 Delmar Dr Laurel, NY 11948 To: install roof-mounted solar panels as applied for. At premises located at: G V\ to l 0 2370 Delmar Dr, Laurel © SCTM #473889 �C7 5 f'q Sec/Block/Lot# 127.4-24 Pursuant to application dated 10/2/2020 and approved by the Building Inspector. To expire on 4/16/2022. Fees: SOLAR PANELS $50.00 CO-ALTERAT TO DWELLING $50.00 CTRIC $100.00 Total• $200.00 Building Inspector Pontino, Susan From: Lorraine DiPenta <lorraine.dipenta@e2sys.com> Sent: Thursday,August 20, 2026 8:54 AM To: Pontino, Susan Cc: permits@e2sys.com Subject: [SPAM] - Re:Schwamborn, 2370 Delmar Dr, Laurel Hi Susan, Yes please void this permit it was a cancelled project. Thank you, Lorraine DiPenta Project Manager Element Energy LLC 7470'Sound Avenue Mattituck, New York11952 C: 631-388-7041 P: 631-779-7993 0 On Thu,Aug 20, 2026 at 8:46 AM Pontino, Susan <susan.pontinoC@town.southold.nv us>wrote: Good morning, We have an expired permit for Schwamborn from 2020 for solar panels with no inspections done. I was just confirming this project was never done so I can void the permit. Thank you. Susan Pontino- . 1 FIELD;INSPECTION REPORT DATE Gfi)1VITS {- FOUNDATION(1ST) FOUNDATION ROUGH]FRAMING& • 1 PLUMBING '\H INSLZATIONTER N..Y. STATE ENIPRCY CODE '..• :: .. : INAL ADA' ,. -, TOWN,OF SOUTHOLW BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL °Board of Health SOUTHOL%NY 11971 4 sets-of Building Plans TEL: (631) 765-1802 _ Planning Board approval - FAX: (631)765-9502 �� Survey Southoldtownny..gov . PERMIT NO:. ✓ Check Septic Form N.Y.S:D;E:C. Trustees . C.O.Application Flood Permit Examined 20 Single&Separate Truss Identification Form Storm-Water`Assessinent Form 2 Contact: ��. ��► Approved. ;20 Mail to: E(p hu o ,inn t p I_ Disapproved a/c Ck W f« 1, Phone: (031-7,79. 7993 Expiration r li�U Building Inspector OCT - 2 2Q20 APPLICATION FOR BUILDING PERMIT �<L�'�'PT 1 1�-1OL1� 20 Date I 20 TOE," ;; INSTRUCTIONS ' a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance,of Building Permit. d.Upon approval of this application,the Building'Inspector will issue a Building Permit to the applicant. Such a permit shall-be kept on the premises available for inspection throughout the work. e.No building shall be occupied.or used in whole or in part for any purpose what so ever until the Building Inspector ` issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,:Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as her,.ein.described.The applicant agrees to comply with all applicable laws,ordinances,building code,liousing code,aiid regulations;and to admit authorized inspectors on premises and in building for necessary inspections. LAXt&:-) �t'lprweal ku a t(C (Signature of applicant or name;-if a co ration) WID SWnd: fkr- NOA '.1)q l tC?SZ (Mailing-address ofapplicant) State w7bjether applic nt is wner, les ee, agent, architect, engineer, general contractor, electrician.-plumber or builder ,Name.of owner of premise`s (As on the•taxroll or latest deed) If applicant is a corporation; signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. 52(A9 F .e Other Trade's License No. 1.. Location of land on whiclagposed work will be done: r ,L,�imca-J� House Number Street Hamlet County Tax Map No.'1000 .Section a `1 =0D Block 0 (- Lot 0 a4•OD :`�... . �_ �;, •i.� r Subdivision Filed.Map No.' Lot . 2. State existing use:and occupancy of premis s and-intended use and occupancy of proposed construction: . a. Existing use and.occupancy __ S 1 d o t)C\4 b. Intended use and occupancy Y L St cl 0 n e4 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work Solcir (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling,numbe'r of dwelling units Number of dwelling units on each floor If garage;-number of cars 6. If business;commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing-structures, if any:Front Rear Depth Height Number of Stories . s Dimensions of same structure with alterations or,additions: Front Rear Depth Height -Number'of Stories 8. Dimensions of entire new construction:Front Rear r, Depth Height Number of Stories 9. Size of lot:Front Rear Depth 10.Date of Purchase Name of Former Owner 11.Zone or use district in which premises are situated 12.Does proposed construction violate any zoning law, ordinance or regulation?YES NO r 13.Will lot be re-graded?YES NO /Will excess fill be removed from premises?YES NO 14.Names of Owner of premises_ lVDM Address 23-D Delma-�)r LL&hone No. -935- 02_21S Name of Architect Address Phone No Name of Contractor_L=(omon-f -;a"u 11C Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO *IF YES, S0iJTI4OLD TOWN TRUSTEES&D.E.C.PERMITS MAYBE REQUIRED. b.Is this property within 3*feet*of a tidal wetland?*YES NO *IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property? * YES NOJ *IF YES,PROVIDE A COPY. STATE OF NEW YORK) COUNTY OF Sg� T6 K) Coo. b being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, n (S)He is the l_()(l7Y C, (. r-�r (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this-application; that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner.set forth in the application filed therewith. Sworn to before me,this at� day of 20 ,P d- / PATRICIA A MAY N"A-R-V PUBLIC-STATE OF N Public Notary Publ No. O1 MAa67.6G3a Signature of Applicant Quollfled In Suffolk County ti . My Commission Expires March 30, 20a,�., BUILDING DEPARTMENT-Electrical Inspectof TOWN OF SOUTHOLD o Town Hall Annex - 54375 Main Road -.PO Box 1179 o - Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr17a southoldtownny.gov — seand c@southoldtownn .- ov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (Ali Information Required) Date: L25-L20.zo Company Name: El..c►LtW,.r EP&M C.L.G Name: �Jww Kc n r c License No.: 52M- He email: ;}� e com Address:. Jq%1.C) So P_. V953 Phone No.: JOB SITE INFORMATION (All Information Required) Name:- _.�o�s� lLcuos n bin Address: 23-70 LEI mo r g- Z-QL r I f g q Cross Street: rp Ud Phone No.: Bldg.Permit#: email:_ a4 Tax Map District:. 1000 Section,_ -Block-:--.- Lot:. BRIEF DESCRIPTION OF WORK (Please Print Clearly) RuS L 02CP molen� 12 eoc n off.y0_ 3 o ca.r� aIda Rui� Circle All That Apply: oFinal Is job ready for inspection?: YES NO Rough In Do you need a Temp Certificate?: YES NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: _A # Meters Old Meter# New Service - Fire Reconnect- Flood Reconnect- Service Reconnected - Underground-- Overhead # Underground Laterals 1 2 H Frame Pole . Work done on Service? Y N Additional Information: PAYMENT DUE WITH'APPLICATION q-7 Request for Inspection FormAs ICA PPROVED AS NOTED C("MPLY WITH ALL CODES OF ' NEW YORK STATE & TOWN CODES DATE: / O .B'P.,#� � AS REQUIRED A NS,OF FEE: BY: ! f� SOU T NOD TO NOTIFY BUILDING DEPARTMENT' AT 765-1802 '=8 AM :TO 4 PM FOR"THE S LD TOWN PLANNING BOARD FOLLOWING'INSPECTIONS: S HOLD TOWN TRUSTEES 1. FOUNDATION TWO"REQUIRED FOR .POURED CONCRETE. N.Y.S.DEC 2. ROUGH -.FRAMING &' PLUMBING 3. .INSULATIOf 4. FINAL - CONSTRUCTION'..MUST CCGU�e��C� BE COMPLETE FOR. CO..-'. OR ALL CONSTRUCTION SHALL'MEET THE USE IS UNLAWFUL REQUIREMENTS OF,THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR WITHOUT CERTIFICATE DESIGN OR CONSTRUCTION ERRORS. OF OCCUPANCY RETAIN STORM WATER RUNOFF PURSUANT TO CHAPTER 236 OF THE TOWN CODE. Town of Riverhead September 25th, 2020 Building Department 201 Howell Avenue Riverhead, NY 11901 Subject: Roof Mounted Solar Panels at the Schwamborn Residence, 2370 Delmar Drive, Laurel, NY 11948 To Whom It May Concern: hereby state that it is my professional opinion that the subject plans comply with the 2020 Residential Code of New York State, the 2017 National Electric Code,ASCE 7-16, and NFPA-70. These code requirements include the fact that the roof framing is adequate to support the additional loads from solar panels as well as roof ridge and peak access to first responders. I have evaluated the structural framing of the existing roof with the additional loading to account for the proposed solar panel.application. Deflection and stresses of the structural components remain within the allowable for the existing roof for wind pressures from 130 mph, 3 second gust, Exposure.B.with a.ground snow load of 20 pounds per-square foot. Mounting locations and methods are as indicated in the submitted plans. From the site inspection and analysis, and as evidenced by previous roof loads withstood, it is my professional opinion that the existing building-and roof framing is structurally adequate to support the reactions of the solar panels in addition to the existing code required live and dead loads.Also the wind analysis concluded that the mounting system as shown on the plans is adequate to resist the calculated uplift pressure. The dead load of the heaviest solar panel assembly in this evaluation is approximately 2:7 pounds per square foot. Please contact me if you have any questions or comments about the above. Sincerely, OF NEi,�,� DEER O James Deerkoski,,PE r ' � _• � *Q, 260 Deer Drive i uWi Mattituck, NY 11952. N�oA � 631-774-7355 ��FESS10 SCOPE Of WORK --- ----- --z-- DESIGN t DRAFTING BY ' ELEMENT ENERGY LLC "TAL!. - JVOLTAIC(PV)SYSTEM AT THE 5CHWAMBORN RESIDENCE, REVIEW 13YJ.M.NA13CEP CERTIfIE LOCATED AT 2370 DELMAR.DR, LAUREL, NY 1 1948(40.96.7132, -72.551007). 051 1 12-129 THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING FI F�-rrrr^AL 5ER\!ICE FO!11PMFNT THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES. REVISIONS "YF ',LE AND HAS AT LEAST MINIMUM 10 YEARS OF REMAINING LIFESPAN -- DE90RIPTION DATE REV TILT AZIMUTH 20° 235' a} SYSTEM RATING -+---t— kW DC STC EQUIPMENT SUMMARY ,ATT PV MODULES CONTRACTOR 40 ENPHA5E I07-G0-2-U5 MICRO tNVERTER5 Nonw k aae: I IRONRIDGE FLA5HFOOT2 FLASHING SYSTEM r ,_.r.G SYSTEM CEMENT ENERGY, LLC 5H EET INDEX N _ OF Ni V 7470 SOUND AVE Y 'ATTITUCK. NY 1 195 PV- COVER 00 P� r�LE,�� 0-Q PV-2 SITE PLAN LICENSE # 43869-H PV-3 ROOF PV LAYOUT `�' r .' .?s� * _ICENSE # 52G89-ME PV-4 STRUCTURAL/DETAILS 4 SECTIONS PV-5 3-LINE ELECTRICAL DIAGRAM W 270°p o 90°E Cl s w PV-G LABELS GOVERNING CODES Zao° Q 120° ��o 25O • �� 2100 1500 q, N�� PROJECT NAME 2017 NATIONAL ELECTRICAL CODE. 180° �FE 2020 RESIDENTIAL CODE OF NEW YORK STATE, LLJ ASCE 7-1 G AND NFPA-70. S `�� U UNDERWFUTERS BORATLu OSHA 29 CFR i 9 RIE5 (UL)STANDARDS —" - ""`- — Z PROJECT LOQCATION o _ co GENERAL NOTES, NOTES n ; 4�M• ,� cn o m 1 . CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT t *4p Lu _ s THE 51TE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE �. ,. r •4 ,• CLIz Q HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK "i�5• AGREE THE SAME. 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED LLJ APPROVALS, PERMITS, CERTIFICATES OF OCCUPANCY, 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. 0� f"� �, '�ir'j' CD C) W INSPECTION APPROVALS, ETC.. FOR WORK PERFORMED FROM CONTRACTOR'S LIABILITY, WORKMAN-5 COMPENSATION, AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED, COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND e - Q ALL RULES AND REGULATIONS OF THE RESPONSIBLE OF TH15 PROJECT AND FURNISH PROOF OF SAME PRIOR TO it COMMENCING WITH WORK. I I . EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FO x JURISDICTION. 4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS RE o •"�'' WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, MAINTAINING SAFETY ON THE JOB SITE DURING THE CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE �•C AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND r' fr ��` -- ENGINEER. SHOULD HE FAIL TO FOLLOW THI5 PROCEDURE AND �, h CONTINUE WITH THE WORK, HE SHALL A55UME ALL HEALTH ADMINISTRATION. THIS SHALL INCLUDE, BUT ARE NOT . r�r LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, ♦ �' RESPONSIBILITY AND LIABILITY THEREFROM SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY SHEET NAME 5. ALL STRUCTURAL STEEL SHALL BE A-3G AND SHALL BE j. > �r, %X. . SCAFFOLDING, STAIRS, ETC.. A5 WELL AS PERMANENT41 FABRICATED AND INSTALLED AS PER LATEST A.I.S.0 CONSTRUCTION. SPECIFICATIONS. - CQvLr- 2. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE 6. ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE _. r •� ,; UNDERWRITERS APPROVED AND IN ACCORDANCE WITH N.E.C. t DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EX15TING � CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING 7. CODES REGULATIONS CONDITIONS PRIOR TO ORDERING MATERIALS AND ` ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN .�1_ •'. " � f COMMENCING WITH WORK. DRAWING SCALE CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S JN CERTIFICATION OF THESE PLANS. 13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS ,► a t 8. THESE DRAWINGS AS IN5TRUCMENT5 OF SERVICE ARE AND WORK FROM THE SITE AND DISPOSE IN A LEGAL MANNER ON N .T. i •T•5• A WEEKLY BASIS OR SOONER IF CONDITIONS IONS WARRANT. _ _ I V SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE 14. AT THE COMPLETION OF WORK, THE SITE TO BE CLEARED \ � PROJECT FOR WHICH THEY ARE MADE 15 EXECUTED OR NOT. e THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR OF ALL DEBRIS AND EXCESS MATERIALS. THE FACILITY 15 TO BE LEFT 3-.- BROOM CLEAN AND WORK 15 TO BE COMPLETED TO THE EXTENSIONS TO THIS PROJECT TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF d ��; SHEET NUMBER 9. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL FINAL PAYMENT. AERIAL VIEW PV— EXISTING WORK ADJACENT TO HI5 WORK,OR DAMAGED AS RESULT OF HIS WORK. TAX MAP: 10001 27000400024000 CONSTRUCTION NOTES DE51GN 6 DRAFTING BY: 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE ELEMENT ENERGY LLC MANUFACTURERS INSTALLATION IN5TRUCTION5. o REVIEW BY J.M.NABCEP CERTIFIEC pp o 051112-I29 2.) ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. p 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. p a ^ry UV151ON5 Q ^�� F PfION PAT[ .REV O 109-24-202C 0 p ^p ^� CONTRACTOR ELEMENT ENERGY, LLC. i IL 7470 SOUND AVE J � MATTITUCK, NY 1195 u u LICENSE # 43889-11 LICENSE # 52G89-MF 0 1 7'- 104" m PRCUWT NAME LLI 6 211 U LLJ > 0o 18"FIRE 5ET5ACK @RIDGE Q 18"FIRE SETBACK @RIDGE W Z O W Z a a J W / O L Q ^ D 17 '-9211 = N g LEGEND a v1 ®EASTIN0 UTKM METER MAIN SERVICE PANEL to m NEW PV SUB-PANELS A/C DISCONNECT comemm \ OF N E�y y 9MEt7 NAME INVER7MGND ELECRWM [`]PVC �L. % s JITE Fb-v RACKING RAIL * ~� CY_ O ATTACHMENT PONT r c uj ---RAC 23'-2 " 46'-G" ?�� ��..sn2 , �� DRAWNGSCAIF .4--ROOF PITCH ANGLE 2 o ffjSUNRUN METER o S\oo c, N T.N„E14T . OPLUMBW VENT ®SKY LNWT Sntt\T/NUMf3leR cHMiNEy OOMPOSM SHINGLES GOOD COPDITIM POTENTIAL SHADM ISSUES _ —`— JTW/RE]WVE AS NECESSARY TAX MAP: 10001 27000400024000 CONSTRUCTION NOTES CONSTRUCTION SUMMARY TAX MAP: 1 0001 27000400024000 DE5IGN o DRAFTING BY: 1 .) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE (40) QCELLS Q.PEAK DUO BLK-GG+ 340 WATT PV MODULES ELEMENT ENERGY LLC WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. (DIMENSIONS: GG.3"x 39.4"x 1 .3") REVIEW BY J.M.NABCEF CERTIFIED 2.) ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH (40) ENPHASE IQ7-GO-2-US MICRO INVERTERS 051 1 12-129 MINIMUM NEMA 3R RATING. (70) ATTACHMENT POINTS @ G4" OC MAX. 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE (302.7) LF IRONRIDGE XR100 MOUNTING SYSTEM. _ REVISIONS FIELD VERIFICATION. ROOF TYPE = ASPHALT SHINGLE(SINGLE LAYER) DMRJFnON DATE REV 09-23-2020 t Cjl ARRAY #2 4 MODULES -- O 20'PITCH --- -_ Q r\� 58'AZIMUTH o O o ^� CONTRACTOR 41- 1 12 ELEMENT ENERGY, LLC. 7470 SOUND AVE MATTITLICK, NY 1 1 95 w (n LICENSE # 43889-H —-•-----• v ICENSE# 52G89-ME � v I GI-(5 I II .�' v2 uT �J W U1 PROJECT NAME O1D m W U z Lu � � moo" 18"FIRE SETBACK @RIDGE LLJ Q 18"FIRE SETBACK @RIDGE z I I UJ 4 `, CL/ 1 > its ir ri T. ,, , T7 N Q) LEGEND t Q U ®0 E)OSTING UTIUrr METER -1 MAIN SERVICE PANEL w NEW PV SUB-PANELS Li �� 1s .- :_i _I_S 1 }# ' i i ! ; t i i 1 d L i i ! I ��, _ i I+l j i t 1�1 i [:_11 ru I n A/C DISCONNECT � � �- 1 COMBINER INVERTERS - - SHEET NAME GND ELECTRODE M . ._. -- - _. ----'— -- . ._ -..- _. _ _ -- . _ - _ i . - - _ lD PV MODULE m 0 0 F D L I K RACKING RAIL I'i'y0 o ATTACHMENT POINT �,_9 „ DEE ,n ---RAFTERS I I-^711 �PNF'�, � 'i��kkQ r�// DRAWING 5CALE ♦--ROOF PITCH ANGLE * �� . eSUNRUN METER N�,T ARRAY #I s N .T.5 3G MODULES ti 0PLUMBING VENT N "•• - '` V 20°PITCH FU 2 ®SKY UGHT ® 2380 AZIMUTH CHIMNEY 3I-9 III OFE5SVA?"; 5HEET NUMBER COMPOSITE SHINGLES 2 v \ GOOD CONDITION 1 P V/ -3 POTENTIAL SHADING ISSUES jTRIM/REMOVE AS NECESSARY LOAD CALCULATION A.RPAY'IV I ARRAY#2 ITEM DE5CRIPTION ARRAY#I s#2 DE51GN t DRAFTING BY: R15 Rid6le Bearn/Board ELEMENT ENERGY LLC MODULE WEIGHT(Lbs) 43.9 43.9 K Rafters 2 REVIEW BY J.M.NABCEP CERTIFIED (D) Deckiri-q 5, 05 i 1 12-129 #OF MODULE5 3G 4 (P) Pitch 21. TOTAL MODULE WEIGHT(Lbs) 1 580.4 1 75.6 W Ceilincl J015t 2 REV1510N5 E Collar TIe5 [DE5CFJFT1ON DATE REV TOTAL LENGTH OF RAIL(Ft) 275.0 27.7 Horizontal 5 -it of(R) K,_z3_Zc2 RAIL WEIGHT PER FOOT(Lb5) 0.68 0.C5 —r- TOTAL RAIL WEIGHT(Lbs) 157.0 18.8 #OF 5TRANDOFFS G2 8 WEIGHT PER 5TRANDOFF(Lb-,) 2 2 (D) -- - TOTAL 5TANDOFF WEIGHT(Lbs) 124 1 G TOTAL ARRAY WEIGHT(LLtt.) 1891.4 210.4 \ POINT LOAD(Lb ) 30.5 2G.3 CONTRACTOR. TOTAL ARRAY AREA(5q Ft) C99.5 77.7 ARRAY DEAD LOAD(Lb Scl Ft) 2.7 2,7 CLEMENT ENERGY. LLC. s per CE 7 - Method I: i - a e - (C) 7470 SOUND AVE MATTITUCK. NY 1 1952 net =A Fzt I rnetJUe - t 5ec 1 ne a e # O LICEN5E # 43889-r CLIMACTIC AND Ground Ind 5peec Live load, Point Max fastener ICEN5E # 52G59-N GEOGRAPHIC DE51GN Category Snow Load 3 5ec gust pnet30 per pullout load Fastener Type spacing along CRITERIA Pg mph ASCE7, p5l lb. rails, in. A # 20 130 # 468 5/1 G"x 6" 5tamle55 Steel Roof Section 5 # TYP. TYP, # TYP. lag Bolts 64 # PROJECT NAME For SI: 1 pound per square foot=0.0479 kPa, 1 mile per hour=0.447 m/s. "-- -- LLJ a. Weathering may require a higher strength concrete or grade of masonry than necessary to satisfy the structural U requirements of this code.The weathering column shall be filled in with the weathering index,"negligible,""moderate"or"severe"for concrete as ��� Z Lu determined from Figure R301.2(3).The grade of masonry units shall be determined from ASTM C 34,C 55,C 62,C 73,C 90,C 129,C 145,C 216 Q _> 00 or C 652, _ E/ b. The frost line depth may require deeper footings than indicated in Figure R403.1(1).The jurisdiction shall fill in the frost line depth column with n C the minimum depth of footing below finish grade. ROOF FRAMING DETAIL n LLI C. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local C subterranean termite damage. Q d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301.2(4)A].Wind exposure :�i z category shall be determined on a site-specific basis in accordance with Section R301.2.1.4. e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the O W International Plumbing Code. Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience (D C) ICJ as determined by the building official. MODULE MOUNTING CLAMP 7� 0 D—/ f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. Q g. To establish flood hazard areas,each community regulated under Title 19, Part 1203 of the Official Compilation of Codes, Rules and 50LAP MODULE '> m Regulations of the State of New York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a 5TAINLE55 STEEL 3/8" = N minimum,special flood hazard areas as identified by the Federal Emergency Management Agency in the Flood Insurance Study for the community, BOLT AND NUT U as amended or revised with: I.The accompanying Flood Insurance Rate Map(FIRM), f� ii. Flood Boundary and Floodway Map(FBFM),and iii.Related supporting data along with any revisions thereto. IRONROGE ALUMINUM RAIL The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. ALUMINUM V BRACKET SHEET NAME h. In accordance with Sections R905.1.2, R905.4.3.1,R905.5.3.1,R905.6.3.1, R905.7.3.1 and R905.8.3.1,where there has been a history of local damage from the effects of ice damming,the jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall fill in this ALUMINUM FLA5HIr1G part of the table with"NO." RU CT U I. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index(BF-days)from Figure R403.3(2)or from the 100-year(99 percent)value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 320F)." T j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air A5FHALT 5HINGLE ROOF F N E W Freezing Index-USA Method(Base 32°F)." �57 IN k. In accordance with Section R301.2.1.5,where there is local historical data documenting structural damage to buildings due to topographic wind A,. ( Nfa DRAWING 5CALE speed-up effects,the jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall indicate"NO"in this part of the table. Nfpf I. In accordance with Figure R301.2(4)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this * r AS NOTE[ part of the table with"YES"and U B ERy m. In accordance with Section R301.2.1.2.1,the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall rr, `u indicate"NO"in this part of the table. Zs n. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(5)for sites at elevations up to �p 2 5n 1000 feet.Sites and elevations above 1000 feet shall have their ground snow load increased from the mapped value by 2 Ibs/ft2 for every 100 feet SHEET NUMBER above 1000 feet. OFES (`) See Figure R301.2(4)B. F " —4 TAX MAP: 10001 27000400024000 MOUNTING DETAIL SOLAR ARRAY ON MAIN HOUSE 13-GO kW DF51GN t DRAFTING BY: (40)QCELL Q.PEAK DUO-BLK GG+ 340 PV MODULES ELEMENT ENERGY LLC (2)STRINGS OF(1 5)MICRO-INVERTERS E(1)STRING OF(10)MICRO INVERTERS REVIEW BY J.M.NABCEP CERTIFIE': -(3)STRINGS TOTAL ON MAIN HOUSE TO UTILITY GRID 051 1 1 2-129 RE NS V15I0 5TRI NG5 #1 4w 2 _ I' _ _ ! _ _ _ _ _ DESCROTION DATE Rev - - - - - - - - - N 09-23-2020 j- -------- ------ -- ( - ----- ---- - --- ------ ----- - --- ---' 81-DIRECTIONAL - — j I-PHAS ,240 V T - —--- - T '�'p UTILITY METER I- -------------------{�] ----' ------ `----'�------1]-._----Ej-._----�_- E1-_---'®- - - --'Ej`-----i E Potts OF INTERCONNECTION PER NEC 240.21(5XI)t 690.C4(A) - I 1{ I /-ItNGTH CF?AP CONDUCTORS NOT E%CEED I O ' I J�_ �1 CONTRACTOR j t- ----- -�` ------ ------�- �------'G" � 2a0 v.200 A I ' I -- ----- `----' ----' "--_- ----' --__,- I nwN sterna DsscONNec� I ( FNPHASE BRANCH ' I CIRCUIT CABLE TYPICAL LhrtlkJL i:aou-z-us ` LEMENT ENERGY, LLC ' I 240 VAC, 1.O A j 97%CEC-WEIGHTEDEFF. 7470 SOUND AVE NEMA G.UL U5TED AC DISCONNECT IATTITUCK, NY I 1052 TYPICAL ( 501)1)223NR8 LICENSE # 43(589-H ' 240 VAC.3R_UL LL3TED aD NEMA 3R, 1 !ICEN5E # 52689-ME I 1 I t 1 1 I I ( MAIN SERVICE PANEL PROJECT NAME I N N �— — — ----- ---------------------------------------------------- W r---------- —t AC COMBINER aM I N U 420 A 1XX)5.E POLE MAKER5 j G I i z LLJ > `IO LLJ j EXI5TING GROUNDING C) I I I ELECTRODE 5Y5TEM uJ -s WIRE CONDUIT SCHEDULE O LLJ CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX. CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP E57MATED Voltage Drop I% LLJ I.D.# ORIGIN DESTINATION SIZE PER POLE QUANTITY DERATE INSULATION SIZE QUANTITY INSULATION (CU/AL) TYPE SIZE TEMP DERATE DISTANCE O 31 O.1 5(B)(3) 311 O.i 5(5)(2ay(3c) Q INVERTERS COMBINER PANEL AWG#10 6 0.5 U5E-2/PV Wire AWG#8 1 BARE CU FREE AIR I,, 709C 0.65 I I O FT 0,6% > OR EMT = N COMBINER PANEL AC DISCONNECT A%G#6 3 THWN-2 G#8 1 THWN-2 CU PVC 0.57 25 0.6%Q AC DISCONNECT MAIN PANEL er 3 THWN-2 - THWN-2 CU PVC 0,57 0.G% ,p- O�- NE w ELECTRICAL NOTES Y� ()L.EI� A�i SHEET NAME CALCULATIONS FOR CURRENT CARRYING CONDUCTORS 10 BE L15TED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION CONFIGURATION +n S5 ALL CONDUCTORS SHALL BE COPPER, RATED FOR GOO V AND 90QC WET ENVIRONMENT. PV Source Circuit Wire Ampacty Calculation * 1 l', 3—LINE ![NEC 690.8(B)(0]: #of 5trnn 5)'(1.5G)— 8.75 A Modules per 5trin r rii ,;.)WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTI 9 P 9 s ,L TO,AND LOCATED AS CLOSE AS P0551BLE TO THE NEAREST RIDGE, HIP,OR VALLEY. Temp Derate= 2( it and, Modules-er Inverter DC wve 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL Number of Inverters COMPLY WITH NEC 1 10.2G. Inverter Output Wire Ampacity Calculation 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL Inverter Max Amperage output'(I.25) = to A Record low tern- 'C �O 25 FURNISH ALL NECE55APY OUTLETS, SUPPORTS, FITTINGS AND ACE550RIE5 TO FULFILL AWG#G. _'onduit Fill Derate)= 65.25 A Voc Tema-Coefficient DRAWING SCALE APPLICABLE CODES AND STANDARDS. 65.25 A> theref, wre size is valid. DC SYSTEM SPECIFICATIONS CALCULA C.)WHERE 512E5 OF JUNCTION BOXES, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, #3 Inverter Output Wire Ampacity Calculation O eratin Current �.O A strin..5)'(Ir " THE CONTRACTOR SHALL 512E THEM ACCORDINGLY. Inverter Max Amperage output'(1.25) = 50 A N .T. , 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. -1,VG#' ;;onduit fill Derate)=65.25 A O eratin Volta e i3.9 V „lo in Seri% Vm:) 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE 25 A> 50 A,therefore AC wire sae 15 valid. Max. System Voltaje 14.5 V 5UPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. Short Circuit Current 3.0 A =;n_r scan s)'(Isc)'(I.25)per Art.690.81r•, 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB LUG AC SYSTEM SPECIFICATIONS SHEET NUMBER OR IL5CO GBL-4DBT LAY-IN LUG. 10.)THE POLARITY OF THE GROUNDED CONDUCTORS IS(posttive/negatv Max AC Output Current e) �\/_� OR O eratin-AC Volta.•e 240 V �/ 10.)THE DC SIDE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC TAX MAP: 10001 27000400024000 DESIGN 4 DRAFTING BY: SERVICE METER 0 BIPOLAR SOURCE © INDICATING AC DISCONNECT INSTALLATION NOTE REVIEW BY .M.ELEMENT BYJ.M.NNERGYLCC NABCNP CERTIFIN ( I ) ALL LABEL SHALL BE INSTALLED IN 051I12-129 WARNING AWARNING ACCORDANCE WITH THE 2014 NEC REv1sIoDA REQUIREMENTS. DESCR PTION DATE R (2) ALL LOCATIONS ARE APPROXIMATE AND '�"� 1�.2c2°I THIS SERVICE METER TURN OFF PHOTOVOLTAIC REQUIRE FIELD VERIFICATION. -- -- -�- SOLAR AC LOAD CENTER IS ALSO SERVED BY A AC DISCONNECT PRIOR TO ---- -- PHOTOVOLTAIC SYSTEM WORKING INSIDE PANEL (3) LABELS, WARNINGS) AND MARKING O O O SHAL2 BE jN ACCORDANCE WITH NEC 0 -- -� -__ 02 AT PV SYSTEM AC COMBINER 07 AT THE POINT OF DISCONNECT (4) THE MATERIAL USED FOR MARKING MUST BE WEATHER RESISTANT, IN CONTRACTOR CONDUIT RACEWAYS COMPLIANCE WITH NEC 1 10.2 1 (B)(3). OWARN I NG DISGONNECT (5) THE PV SYSTEM CIRCUIT CONDUCTORS SHALL BE LABELED INSTALLED IN L7470 5NT 0UNI)AVE O C. PHOTOVOLTAIC SYSTEM COMPLIANCE WITH NEC G90.3 1 . IATTITUCK, NY 1 195 COMBINER PANEL LICENSE # 43889-H DO NOT ADD LOADS ® AC DISCONNECT ICEN5E # 52689-ME RAPID SHUTDOWN SWITCH SEE NOTE (3) (RACEWAYS) • • • O , • PROJECT NAME PHOTOVOLTAIC"' w POWER SOURCE-,- ! Z Lu MAIN SERVICE PANEL � � ` • o > 03 ® RAPID SHUTDOWN SWITCH U) o Lu 0 Q DC DISCONNECT Q RAPID i • C � z AC DISCONNECT/BREAKER SWITCH • PHOTOVOLTAICm w OR COMBINER BOX • ` ' PV SYSTEM , , • QNNEC � mg 7 L N O (-D 05 INDICATING RAPID SHUTDOWN OPERATING VOLTAG-E VD SYSTEM IOPERATING CU MAX SYSTEM VOLTAGE VDC 5NEET NAME SHORT CIRCUIT CURRENT A NE Ew LA b L L--) ui DRAWING 5CALE 2. 1 V . 1 .5. ��'OFrSS,JaA SHEET NUMBER rv-G TAX MAP: 10001 27000400024000