Loading...
HomeMy WebLinkAbout51764-Z $of souryo�o Town of Southold * * P.O. Box 1179 - �0 53095 Main Rd .' utm� Southold, New York.11971 CERTIFICATE OF OCCUPANCY No: 47300 Date: 08/18/2026 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 38015 Route 25 Orient, NY 11957 Sec/Block/Lot.: 15.-2-15.8 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 02/12/2025 Pursuant to which Building Permit No. 51764 and dated: 03/19/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof-mounted solar panels to existing single-family dwelling as applied for. The certificate'is issued to: Luckyfront LLC Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 112800 9/18/2025 PLUMBERS CERTIFICATION: utho ed Sign ture �o4ioFSo&lyolo . TOWN OF SOUTHOLD BUILDING DEPARTMENT 4 TOWN CLERK'S OFFICE �auMr.� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONESET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51764 Date: 03/19/2025 Permission is hereby granted to: Luckyfront LLC 333 Central Park.W Apt 106 New York, NY 10025 To: install roof-mounted solar panels to existing single-family dwelling as applied for. Premises Located at: 38015 Route 25,.Orient, NY 11957 SCTIVI# 15.-2-15.8 Pursuant to application-dated 02/12/2025.and approved by the Building Inspector. To expire on 03/19/2027. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 ELECTRIC -Residential $125.00 CO-RESIDENTIAL $100.00 Total $325.00 Building Inspector • NASSALI ILECTRIC:AL r SUFFOLK INSPECTORS r, 159 Route 25A, Building 1 Suite B Miller Place, NY 11764 R Telephone:631 495 8136 Fax:631 509 4538 • E-Mail:Requests@SuffolkBEI.comPY { CERTIFICATE OF ELECTRICAL COMPLIANCE Applicant: Green Logic Certificate No.: 112800 Rough In Inspection Date: Final Inspection Date: Sep 18,2025 Application No.: Building Permit No.: 51764 County Tax Map No.: LIPA Solar App No.: 2024-385395 This Certificate of Electrical:Compliance is limited to the inspection and compliance of electrical equipment and/or work described ' below,installed on behalf of the applicant named above,located at the premise of and not after the final inspection date above: Owner: Chad Gallant Site Location: Gallant,38015 Main Road,Orient, NY 11957 Owner's Address(if different): 0 Residential 0 Indoor ❑Basement OService ❑Shed n ❑Commercial 0 Outdoor ❑First Floor ❑Pool ❑Hottub x O New ❑Renovation ❑Second Floor ❑Attic ❑Garage F Cl Addition ❑Survey 0 PV Solar ❑Generator O Conversion L Signs ❑Battery Storage ❑Safety Inspection Other: i - - .-- _---------............... .. w, = INVENTORY Single Phase Heat Duplex Recpt Ceiling Fixture 0 Dual Func Breaker x Three Phase Hot Water GFCI Recpt Wall Fixture Smoke Main Panel AC Cond Single Recpt Recessed Fixture CO Detect Sub Panel 0 AC Blower Range Recpt 0 LED Lighting 0 Smoke CO Combo Transformer 0 Appliance Ckt 0 Dryer Recpt Emergency 0 Time Clock 0 Disconnect Switches Twist Lock Exit Fixtures Pumps GFCI Breaker 0 Heat Pump 0 Electric Heat 0 Pool Luminaire 0 Exhaust Fan 0 Yi. Other Equipment:System Size:29.900 kW Qty:65 Desc:IQ8X-80-M-US City:65 Desc:REC460AA PURE-RX The electrical work and/or equipment described above were inspected and was found to be in compliance with local, F`t M state and national electrical code requirements and this office. Applicant: Green Logic License No.: 43858-ME Date Printed: Sep 18,2025 ,a L Inspected By:Joe,Coppola Signature: 'Y s �R OF SoUTyO� - — . TOWN.O.F SOUTHOLD BUILDING DEPT. °yco 631-765-1802 INSPECTION FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ vr'FINALh✓L [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY-INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ]-'FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [. ] ELECTRICAL (FINAL) [ ] CODE VIOLATION. [ ] PRE C/O [ ] RENTAL REMARKS: Av %Is // Ce4 a G cele DATE ���� . . INSPECTOR Pacifico Engineering PC Engineering Consulting 700 Lakeland Ave, Suite 2B Ph: 631-988-0000 Bohemia, NY 11716 �' G c solar@pacificoengineering.com September 19,2025 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for LUCKYFRONT LLC 38015 Main Road Permit Number: 51764 Orient, NY 11957 1 have reviewed the solar energy system installation at the subject address on September 19, 2025.The units have been installed in accordance with the manufacturer's installation instructions and the approved construction drawing. I have determined that the installation meets the requirements of the 2020 Residential Code of New York State and ASCE 7-16. To my best belief and knowledge,the work in this document is accurate, conforms with the governing codes applicable at the time of submission, conforms with reasonable standards of practice,with the view to the safeguarding of life, health, property and public welfare. Regards, Ralph Pacifico, PE Professional Engineer Pacifico Engineering P.C. Certificate#0018074 ca'� �Qk% 'A Cl ®� Al gg0��661 8 Rat � Engineer NY 0661 xp.Date 1/31/28 o Ff°tto TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 aa �o� Telephone (631) 765-1802 Fax (631) 765-9502 https:/Iwww.southol.dtownny. ov Date Received APPLICATION FOBUILDING IT For Office Use Only 1 PERMIT NO. 511 1A Building Inspector: ,Appl+catI, S and for must be filled out in their entirety incomplete h �t oa w cepedW nwnt a Or uner's AuthorEzatian form(Page 2)shall be completed E s Bazilciin f so t 08t� Date:12/26/2024 Name:LuckyFront LLC __..._.. _..... _..._......._._. ...._... SCTM^# Project Address 38015 Route 25, Orient, NY 11957 Phone#: Email: Mailing Address:333 Central,Pak W,,Apt 106, New„York, NY 10025 __ w GONTACF'PERSON � Name Barbara rGreenLogic LLC Mailing Address:97 North Sea Road, Southampton, NY_11968 M __ Phoneµ#:631.771 5152 x117 _ Email BarbaraPGreenlogic,com DESIGN PROF ES SIONAIINFw ORMATION ., Name Pacifco Engineering PC _. ..... w. _ __ ......_..w_ ._,.._ _.. ... _,.. Mailing Address 700aLakeland Ave, Suite 2B, Bohemia, NY 11716 Phone# 631 v 988 0000 ._.._ ._._ ._ Email solar@ppclficoengineering com CONTRACTOR INFORMATION' rA_ „��v, _. . 011 er Name:GreenLogic LLC Mailing Address:97North Sea Road,rSouthampton, NY„ 11968 Phone_# 631 771-51M52 ... .. ... .... . ...__ Email:AM@Greenloaic.com 3 VC DESCRIPTION OFrPROPOSED GQNSTItUCT1QIV �� sz � ❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated cost of Project: 20ther Solar Panels $ 103,000 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ®No 1 wo ; , .. .:.• .s" ., a,., ,_, «Yrre ,,:.,w„ >€,t ,: ,., .. ,n3 � y Jxlo^•EK , ,'. s1,9';> , a tj, ._ Existing use of property: 6StGj Intended use of property. Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ((No IF YES, PROVIDE A COPY. h k Af r n T e ntr "" ) espanxl ! 011i starm Water ift-00",,236 of the al T1gN I5 ti );Ee�r t to ha° u�ld�ng t ari men b a� at,ll mg har i tit t1�e ut lin a►�e q cs of tl a TaI U [;,County,N'a art<a c a " lkable tdw!a qpamc s ar,Re Flo, to tN s ct an af, I�gs fz add ns�r arEarr I o" llt on as herein de e p N�iaant age to'anmp Iars�,ordtnance� , [ end'. h�°ti„ e,hd reut �tta7ns and'tod9tnr !ns# "' o "ro dl '""b Iri (s1.for"n nns� alse stateu' a i nii�alile aka Ctass A"m sdemeaar pursua �a AApplication Submitted B (print name): GreenLogic LLC pP Y�P ®Authorized Agent ❑Owner Signature of Applicant: Rate STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Nesim Albukrek being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)he is the-Contractor (Contractor,Agent, Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of 1" V O 2025 Y Notary Public BARBARA A CASCIOTTA . Notary Public-State of New Yo* PROPERTYE AUTHORIZATION No.01CA4894M (Where the applicant is not the owner) Common xpiresMii 20V I, JQn-AA4i l Old u 0 11611 / residing at GreenLogic LLC do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Mo. z 114 -z y Owner's Signature fDate /.14 two OIL !r Print Owner's Name 2 BUILDING DEPARTMENT- Electrical Inspector ► � `'ir TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(cr�southoldtownny.gov seandC&-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 2/7/2025 Company Name: GreenLogic LLC Name: Robert Skypala License No.: 43858-ME email: Barbara@Greenlogic.com Phone No: 631-771-5152 ❑✓ I request an email copy of Certificate of Compliance Address.: 97 North Sea Road Southampton, NY 11968 JOB SITE INFORMATION (All Information Required) Name: Luckyfront LLC Address: 38015 Route 15, Orient, NY 11957 Cross Street: Phone No.: Bldg.Permit#: email: Tax Map District: 1000 Section: 15 Block: 2 Lot: 15.8 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Roof mounted solar electric system **(65) REC460AA PURE-RX panels Et (65) Enphase IQ78x micro inverters (1) Enphase IQ Gateway ENV2-IQ-AMI System Size: 29.900KW Check All That Apply: Is job ready for inspection?: ❑YES ❑✓ NO ❑Rough In ❑✓ Final Do you need a Temp Certificate?: ❑✓ YES ❑NO Issued On 2/7/2025 Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A #Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground ❑Overhead # Underground Laterals ❑1 02 ❑H Frame❑Pole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION Electrical Inspection Form 2020.xlsx GREENLOGICO ENERGY February 9, 2025 Town of Southold Building Department . Town Hall 53095 Route 25 Southold, NY 11971 Project Info: Luckyfront LLC 38015 Main Route Orient, NY SCTM: 1000-15-2-15.8 Dear Building Inspector: Please find attached a building permit application to install a roof mounted solar photovoltaic(PV) electric system for the above referenced property. In connection with this application, please find attached: • Building Permit application with owner authorization • Application for Electrical Inspection • 2 Surveys of the Premises • 4 Engineer's Reports • 2 Three Line Electrical Drawings • 2 Spec. sheets of the solar panels/inverters • 2 Spec. sheets for Racking System • 2 Spec. sheets for Monitoring System • GreenLogic Suffolk County Home Improvement License • GreenLogic Certificate of Liability Insurance • GreenLogic Certificate of Worker's Compensation Insurance Coverage • Installation Manager's Master Electrician's License • Check for$325 ($100 Building Permit/$100 CO/$125 Electrical Inspectio E C E nn V Please let us know if you need anything else in connection with this application. Yours truly, FEB 2 2025 53adiww ewcW& Building®apartrnera4 Town of Southold Barbara Casciotta Account Manager Barbara@Greenlogic.com GREENIIffilG�1 �C5fSAZ& I ogic.com Tel: 631.771.5152 Fax: 631.771.5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd.,Suite 3 200 S. Service Rd.,#104C Southampton, NY 11968 Rosyln Heights, NY 11577 GREENLOGIC" ENERGY December 10, 2025 The Town of Southold Building Department 54375 Route 25 P.O. Box 1179 Southold, NY 11971 Project Info: Building Permit No. 51764 Luckyfront LLC 38015 Main Road Orient, NY To the Building Inspector: Enclosed please find the Electrical Certificate and Engineer's Certification Letter for the solar electric system we installed at the above reference address. I have also enclosed as built plans as the layout changed slightly from original plans. Please arrange to send the Certificate of Occupancy and close out the building permit. Please let me know if you have any questions about the installation. Sincerely, 53wi6 ma ewchWa C Barbara Casciotta Account Manager 4 Barbara@Greenlogic.com �F 631-771-5152 Ext. 117 GREENLOGIC LLC•www.GreenLogic.com Tel: 631.771.5152 Fax: 631.771.5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd.,Suite 3 200 S.Service Rd.,#104C Southampton, NY 11968 Rosyln Heights, NY 11577 Nu1t�8HLL�P�`x1W T�Ol1E�ro won�3�A�vEY�n�I�Aba�N,m mwtPErol�l�m�ie�mAa�r�6Or�($w�`a1Wr��unlFr�eas�'nx w�uai�m�lArora�ro AssmiJ;.sa.�iE�a�crcnm�al�m�vw�is.ce�roiMu�ua�A roAO��My�`is�aasmm�q�Blr�wrtmas�c'.Rnf�iaA�irw�iaWB�iA Iw m�neT�PO<i�(srle e�asvP�P.®[ �uri�Pmn�uari aaYuam�T�rwrcaA H omvwlEo 400 0.t,.d Avors:e,RNnh—d,N—YPrk 114DI N76"48'29"E �` tP1.aal.Tzr Fox.a31.TSFoaa 16.58, LOT COVERAGE _ BUILDABLE AREA VMWARDOFLEHA).253,996s4FT. 4i}f �tS�VCt QS �L, FRAME HOUSE =1,9765Q.FT, xOAK FRAME 6ARA6E =7BA SQ.FT. =0.3% Txomm G,Wo rt,Froio�eslowl rygnePr �O M9 //�//• �`\ POOLENCASED PORLH a 1,CCM SQ.FT. .0.5% DouglPeD tPIppooA YbGvor,Lmd Strvoyor Ad4mR, r'ql r OJ �p0 ris ,� ��f^ Pea Houses =ANsQ FT. =ois SITE DATA y ///ir/! / o `\ TOTAL.9.4105Q.FL ctli AREA=6.9584 ACRES // � AIN FRAMEHOUSE66ARAQ -3EXLSTINS TO�,926SOFT. .Las //��,S4j �w� /�/i/// 7 8/ $P �i Iq WOOD DES .z�SQ.FF7, --L(m W O� 1�vv�lr//i ` ei5 FRAME GARAGE v7BA `LOTNUMBERS RUM TO SET-OFF MAPPPBARED FOR AMELIA MENbOZA POOLS =2A365Q.FFr. =Lo% ��A_5yyoFFUEOFTHEpacoFwFroLeeouNlroNFEB.ss.mwAs POOL HOUSES c4UnFT. a02i `VERTICAL DATUM -NAvD(1960 CABANA 66 FL .DO% �ii/i J/' �'awG�• \'� 54' IN //% J / \ o (F"�Y TDTAL=10,8775Q.FT. -4.3% APPROXIMATE / d /��//JJJJJ/ i `— sadA� f='�"ice��l 4`� mow•` F DRAINAGE DESIGN CRITERIA A CALCULATIONS V=ARC A-AREAOPTRIBUTARY(SFJ =RAAIPALL6T'.) C eCOEFFICIENTOP RUNOFF //%p/ I 1 � 9R �•a `� •Fi. mw .v®ePxvuxm.nsp 9 �. /r IlIII'J o I VP' a k � .d ��r y'� I*,ID9 tab '� ug��-rwze•os�oorwer. .me OOASTAlHp4plfWAFq A9IA WlA.b. I ( 14� > ..46e' - �� \b GOOF J44RWRlO.Wp wnwArapRiraNA.wAFsoFsnr2 ) (•`e rrd>4p \ e�eueRweawnHAevAapnaxzypm mrA.Fap f ,c� rtAFueAawAaarx®FinamurA� �b I 6s !'—�., \ N�Lot l Co—gy „g ``�\` yy wieu.am.aawPlgw+1R eouRpinoAtmovame .fd' .ssf f a�' Y eY' ,, ��¢.1� t7YL g W'� IMF�J�.1.e'R4xe•O®0eTM8l .k9p �lyP op„0 \�� _ .umvRva:u.uPs O \� •✓9 / ' i, "� I ' •'y."t, +(•` C6iAe:]OeE1LWR11A WAp1YOP e211pm TOUL•169V N ``\ 9� usorAwpm•.Rvrsla�m �9`b �n ������'�\��aNp�Vz'�1 1. � /.�3«�.� ze'.i �\ 9E''� £ ``�`\ �•yes �n�,E usEtn•rouze•R®unweu .Ease �sS of J' ap'2• p.t � / __ N° off" �� q � oe .seam.1, {,/o �\ '��� oD: 4 •�/• Jl t9` \ �p.o Door .ewszwxu.ma ' \ , •U v \ CAs /, '`�J r \.o%p\'ems e•ounmeOF.W+mAewAesFvweuaam mrA.ma cde \ 1t� \�� \ \ 1 ``� 'Q� walnsep'm.uwc[awa3t iY.'P"'heY�c�e,�1A ••� \� ! 1 fl 4 � \ ``\ �` 'C, use01-r ouxao®ovrwsl .usp opN `Y 5'y � � asv' 3 i+\\ � +V'/' i r• +dy � � may#• .O� \ O +4 a\ a, SURVEYOR'SgCERTIFICATION d 0T Aw mM'>oAY 9 `WEF831EBYCERTIF/TO 13 D HAD ALLANTTHATTHIS SURVEY WAS PREFARMINACCORDANceADOPTED BY HE N OY W RK STATE ASSOCIATION��W FFEERIAPIDS:5 THE $$ /�' • `�wp SURVEYORS. 16 HOWMD.WEAVE N.Y.S.L5 N05UM LEGEND �`` � � `ews' DANIB A.WEAVER,NYA LS N0.oe 5P7/1 J� SURVEY FOR AP - s"P �i� OdR �g Lot 2 `� CHAP GALLANT BP c ff=PATIO Bsw -BRICKSIDEWALK k CA /' ¢ " at Orient,Town of Southold ae .CASTOIONCOVER G'� v t \ \;r Suffolk County,New York CE a =coNaEm am w CUP -o a Lawn TRANCE ��2 / ?;pa a BUlLDIIJS PERhAIT SURVEY 1 CSW .CONO1ETE 51"ALK G ' I CMF aCONC1EIE MONVMEM FOVND Z �d�, 2 cAis =CONCIETEMDNUMENTSET 9 / "�" ,Z'�.IOJ. ``\ s�,ps9 ```` P DI -ORAOJ INLETFENCE L •S o� ,�Ta' Qwtyr Map avx,1000 s«Fa. 15 x.02 �,+ 25.8 EPA =DEERFETER T. MAP PREPARED NOV.OA,20t3 ET a EITRANSFORMER �,F,� ET =ELE-eb6TRANSFORMEII 9� 4 aA• ` �w EOP ED6EOFPAVFAILNT d y Record ofRevisions 6v =SAS VALVE \ REVISION DATE N HC a HoUsEhNEC7ION Ls =LATHSET •t v PROPERTY LINE WS eWATER SERVKE 'AS• ` ,TDp ``� ®F ` wDF WOOD FENCE �•7.2..CTj ` —` `\ F WIF -WIRE FENCE N PA�. \ IAMWAMIL¢TOP iDEWMA}& `\3 WS eWOOD STAKE FOUND .F \ 14F1AFm ASPeRIAI®eI w55 .WOOD S� 16 VieANT , ,?i>' ��.�_` /' e,vmL ump1Rcc n.�m9 `\ -UTASTY POLE � O /' \ �\ 60 0 30 60 120 18D Q •L16HTFOLE WELL �o 2! Scale:l"=60' JOB NO 2023.00 DWG.zW3o&_2023_0DZS_b;L N fOF3 as APP 0 ED AS NOTED DA -�B.P.it FEE 06 By NOTIFY BUILDING DEPARTMENTAT 631-765.1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE 2 ROUGH-FRAMING&PLUMBING 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS COMPLY WITH ALL CODES OF NEW YORK STATE&TOWN CODES AS REQUIRED AND CONDITIONS OF SOUTHOLD OWNZBA SOUTHO TOWN PLANNING BOARD SOUTH D TOWN TRUSTEES N,Y,S, EC SO OLD HPC SC D OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICA- OF OCCUPANCY ELECTRICAL INSPECTION REQUIRED i Pacifico Engineering PC _. Engineering Consulting 700 Lakeland Ave, Suite 2B Ph:631-988-0000 Bohemia, NY 11716 )j G PCsolar@pacificoengineering.com _.._. February 5,2025 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for LUCKYFRONT LLC 38015 Main Road Orient, NY 11957 I have reviewed the roofing structure at the subject address.The structure can support the additional weight of the roof mounted system.The units are to be installed in accordance with the manufacturer's installation instructions. I have determined that the installation will meet the requirements of the 2020 Residential Code of New York State and ASCE 7-16 when installed in accordance with the manufacturer's instructions. Roof Section A B Mean roof height 22.0 ft 22.0 ft Pitch 1 degrees 1 degrees Roof rafter 11-7/8"TJI 230 11-7/8"TJI 230 Rafter spacing 16 inch on center 16 inch on center Reflected roof rafter span 19.3 ft 19.3 ft Rafter span max allowable 25.0 ft 25.0 ft EcoFasten ECO-65 w/ EcoFasten ECO-65 w/ (2)#14-13 x 5"DP • (2)#14-13 x 5"DP1 Fastener Type screws into rafter and screws into rafter and (6)#14-13 x 3"DPI (6)#14-13 x 3"DPI screws into sheathing screws into sheathing Allowable Fastener Capability 2125 Ib 2125 Ib Fastener Spacing,Zone 1 /2/3 64/32/48 in 64/32/48 in Point Pullout, lb,Zone 1 /2/3 243/145/217 lb 243/145/217 lb Zone Category 1 /2/3 1 /2/3 1 /2/3 Uplift Pressure Zone 1 /2/3 16/19/19 psf 16/19/19 psf Exposure Category B Ground Snow Load, Pg 20 psf Wind Speed, 3 sec gust 130 mph ,`�1U t array dead load 3.5 psf S P9 P,qc � �v load per attachment 53.2 lb The subject roof has 1 layer of roofing. Panels mounted flush to roof no higher than 6 inches above roof surface. y Ralph Pacifico, PE 066182 4, Professional Engineer ® 7 nl �I Pacifico Engineering P.C. Ralph P � ngineer Certificate#0018074 Nv 066182 i Exp.Date 1/31/2s GREENLOGIC" ENERGY GreenLogic,LLC Approved LUCKYFRONT LLC 38015 Main Road Orient, NY 11957 Surface#A: Total System Size:29.900kW Array Size: 16.100kW 1 circuit of 9 on a 20A breaker(3x) 1 circuit of 8 on a 20A breaker Azimuth: 100° Pitch: 1° Monitoring System: z EnPhase Panel/Array Specifications: Panel:REC460AA PURE-RX Racking: IronRidge Panel:68.0"X 47.4" Array:47'8 7/8"X 17'3/4" Surface:50'9"X 20'1" Legend: ® 3'5- E-AA[pha=Pure--fUM60W 35 IQ8X Microlnverters ® Iron Ridge XR-100 Racking • 74 Eco-Fasten Fast Feet a a TJI 230 x 12"Rafter 16"O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used:Eco-Fasten,IronRidge, REC,EnPhase Added Roof load of PV System:2.32psf Engineer/Architect Seal: OF OAS®�1066182 90NR Drawn By:MA Drawi------ ` Date: 1/21/209 GREENL®CIC® ENERGY GreenLogic,LLC Approved LUCKYFRONTLLC 38015 Main Road Orient,NY 11957 Surface#A: Total System Size:29.900kW Array Size: 16.100kW 1 circuit of 9 on a 20A breaker(3x) 1 circuit of 8 on a 20A breaker Azimuth: 100° Pitch:1 Monitoring System: z EnPhase Panel/Array Specifications: Panel:REC460AA PURE-RX Racking: IronRidge Panel:68.0"X 47.4" Array:47'8 7/8"X 17'3/4" Surface:50'9"X 20'1" Legend: ® 35 REC Alpha Pure-RX 460W 35 IQBX Microlnverters Iron Ridge XR-100 Racking • 74 Eco-Fasten Fast Feet 8 8 TJI 230 x 12"Rafter 16"O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used:Eco-Fasten, IronRidge, REC,EnPhase Added Roof load of PV System:2.32psf Engineer/Architect Seal: V1 PACZF�y®�� J� %A 0661 Drawn By:MA Drawing#2 of 8 Date: 1/21/2025 REV:A Drawing Scale: 1/8"=1.0' GGREENLOGICO ENERGY GreenLogic,LLC Approved LUCKYFRONTLLC 38015 Main Road Orient,NY 11957 Surface#A: Total System Size:29.900kW Array Size: 16.100kW 1 circuit of 9 on a 20A breaker(3x) 1 circuit of 8 on a 20A breaker Azimuth: 100° Pitch: 1' Monitoring System: z EnPhase Panel/Array Specifications: Panel: REC460AA PURE-RX Racking:IronRidge 1 2 Panel:68.0"X 47.4" Array:47'8 7/8"X 17'3/4" YEA Surface:50'9"X 20'1" Legend: 1 3 ® 35 REC Alpha Pure-RX 460W 35 IQ8X Microlnverters lr� I , , , '_ , ® Iron Ridge XR-100 Racking • 74 Eco-Fasten Fast Feet ZLI 0 8 TJI 230 x 12"Rafter 16"O.C. 1 4 Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used:Eco-Fasten, IronRidge, REC, EnPhase Added Roof load of PV System:2.32psf Engineer/Architect Seal: OF ea P�e� P'A A 066182 . > Drawn By:MA Drawing#3 of 8 Date: 1/21/2025 REV:A Drawing Scale: 1/8"=1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved LUCKYFRONT LLC 38015 Main Road Orient, NY 11957 Surface#B: Total System Size:29.900kW Array Size: 13.800kW 1 circuit of 10 on a 20A breaker(3x) Azimuth: 100° Pitch: I' Monitoring System: z EnPhase Panel/Array Specifications: Panel:REC460AA PURE-RX Racking: IronRidge Panel:68.0"X 47.4" Array:51'8 3/4"X 18'10 3/8" Surface:55'X 20'1" Legend: ® 30 REC Alpha Pure-RX 46OW 30 IQ8X Microlnverters Iron Ridge XR-100 Racking • 58 Eco-Fasten Fast Feet 8 8 TJI 230 x 12"Rafter 16"O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Z 7747X7 Materials Used:Eco-Fasten,IronRidge, REC, EnPhase Added Roof load of PV System:2.32psf Engineer/Architect Seal: OF Ue No 0 s 066182 S�� Drawn By:MA Drawing#4 of 8 Date:1/21/2025 REV:A Drawing Scale: 1/8"=1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved LUCKYFRONT LLC 38015 Main Road Orient,NY 11957 Surface#B: Total System Size:29.900kW Array Size: 13.800kW 1 circuit of 10 on a 20A breaker(3x) Azimuth: 100° Pitch: 1° Monitoring System: z EnPhase Panel/Array Specifications: Panel:REC460AA PURE-RX Racking: IronRidge Panel:68.0"X 47.4" Array:51'8 3/4"X 18'10 3/8" Surface:55'X 20'1" Legend: ® 30 REC Alpha Pure-RX 460W 30 IQ8X Microlnverters ® Iron Ridge XR-100 Racking • 58 Eco-Fasten Fast Feet AA 8 8 TJI 230 x 12"Rafter 16"O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used:Eco-Fasten, IronRidge, REC, EnPhase Added Roof load of PV System:2.32psf Engineer/Architect Seal: OF Ncvp/ 4A PA �a 066182 P - aV• Drawn By:MA Drawing#5 of 8 Date: 1/21/2025 REV:A Drawing Scale: 1/8"=1.0' GREENLOGIC® ENERGY GreenLogic,LLC Approved LUCKYFRONT LLC 38015 Main Road Orient,NY 11957 Surface#B: Total System Size:29.900kW Array Size: 13.800kW 1 circuit of 10 on a 20A breaker(3x) Azimuth: 100° Pitch: 1° Monitoring System: Z EnPhase Panel/Array Specifications: Panel:REC460AA PURE-RX 5 Racking: IronRidge Panel:68.0"X 47.4" 6 Array:51'8 3/4"X 18' 10 3/8" Surface:55'X 20'1" ZLLegend: 5 El 30 REC Alpha Pure-RX 460W 6 7 ® 30 IQ8X Microlnverters ® Iron Ridge XR-100 Racking • 58 Eco-Fasten Fast Feet 5 6 8 8 TJI 230 x 12"Rafter 16"O.C. Notes: 7 Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used:Eco-Fasten, IronRidge, REC,EnPhase Added Roof load of PV System:2.32psf Engineer/Architect Seal: OF H PAp0 0 06618 2 C� Drawn By:MA Drawing#6 of 8 Date: 1/21/2025 REV:A Drawing Scale: 1/8"=1.0' No Vent Pipes Will Be Covered By The Solar Array G�GREENLOGIC® ENERGY Legend: GreenLogic,LLC Approved LUCKYFRONTLLC AR-Access Roof AP-Access pathway, 36" minimum width SVO—Setback at ridge 38015 Main Road per R202 definitions per R324.6.1 as per R324.6.2.1 orient,NY 11957 Total System Size:29.900kW 1 circuit of 9 on a 20A breaker(3x) 1 circuit of 8 on a 20A breaker 1 circuit of 10 on a 20A breaker(3x) Azimuth: 190' Monitoring System: N EnPhase Panel/Array Specifications: Panel:REC460AA PURE-RX Racking: IronRidge Panel:68.0"X 47.4" Surface: 139'3"X 74'2" Legend: ® 65 REC Alpha Pure-RX 460W 65 IQ8X Microlnverters Iron Ridge XR-100 Racking • 132 Eco-Fasten Fast Feet 8 8 TJI 230 x 12"Rafter 16"O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used:Eco-Fasten,IronRidge, REC,EnPhase Added Roof load of PV System:2.32psf Engineer/Architect Seal: 35 REC 460W , ®�N� Panels P��rf�® 30 REC 460W ��'' Panels �O 066182 � Meter Drawn By:MA Drawing#7 of 8 Date: 1/21/2025 REV:A Drawing Scale:3/64"=1.0' GREENLOGIC" ENERGY GreenLogic,LLC Approved LUCKYFRONT LLC 38015 Main Road I -�-- T i Orient, NY 11957 JOB MATERIAL LIST Total System Size:29.900kW -- -- `--- - -- - — 1 circuit of 9 on a 20A breaker(3x) _ -_....__. -_- 1 circuit of 8 on a 20A breaker -%�— —' 1 circuit of 10 on a 20A breaker(3x) Azimuth: 190° i Material List gty _ Rail Material List ' t�i. ; - ! Monitoring System: N -- ---- ----- ------------ — T ----- ---�- - —-- En Phase —r---=-� Panel/Array Specifications: " " � - ' —� -�-� Eco Fasten Fast Feet Base Plate 132 Panel:REC460AA PURE-RX—��_ ! I ----I--�--- ack+ng: IronRidge Eco-Fasten Fast Feet Aluminum Block 132 Panel:68.0"X 47.4" Eco Fasten Fast Feet EPDM Flashing --- '--_r-- — Surface: 139'3"X 74'2" �� �� 132 #14-13x5"DPI Concealer Screw 264 Legend: ------ --- - - ----- -- - ------- -- - -- -- —� #14-130"DPI Concealer Screw 792 65 REC Alpha Pure-RX 460W ® 65 IO8X Microlnverters Iron Ridge XR-100 Racking • 132 Eco-Fasten Fast Feet 8 8 TJI 230 x 12"Rafter 16"O.C. ! i Notes: - ----- - s---- =--- — -- - = ---!----- Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used: Eco-Fasten, IronRidge, REC,EnPhase Added Roof load of PV System:2.32psf Engineer/Architect Seal: ! 0661s2 c Drawn By:MA Drawing#8 of 8 ' Date: 1/21/2025 REV:A Drawing Scale:3/64"=1.0' s� SOLAR'S MOST TRUSTED REC EC ' , -'U' RE- R"' " , Q.< ' , "7 s� 9 A MODULE CURRENT COMPATIBLE F a pt m ,fir +�, r q...d k'"'.a, f^'�"s..n. "�`.?i' a •a.} '�. ��y^A +r. � :^w . 450 -470 W 25YE , . , ♦ t3= . MAXf ►REC REC► ® E_RX -SERIES .. MOST TRUSTED ®A TA Measurements In Inches 32.2 1]9.-... 88 half-cut bifacial REC heterojunction cells, Cell Type with gapless technology 0]3 in.solar``gtass with anti-reflective surface treatment' Glass ` in accordance withEN121S0;, y Backsheet Highly resistant polymer(Black) 669 In Frame' "` Xnodizedaluminurn(Black)+ 4-part,4 bypass diodes, R Junction Box IP68 rated in accordance with IEC 62790 Connectors 5taubhMC4PV KBT.4iK5T4(12AWG) to a C 1P68oen cccordanc' t 2 onnected; 12 AWG solar cable,669 in.+66.9in. Cable in accordance with EN50618 oe oc Dimerslons 68X4745c121n(22.4ft')I Weight 50lbs i.. is 0.9 ..................na:o,i7................... . V Ori 'n' Made in5ingapor'e' *ry g 5 0 �'','�, T"'"^`"^",", L�C'�#�ICA A. i r" ,t ©T3 C11�L� CkxxtPure ,, ) AT)t� . ' Power Output-PMnx(Wp) 450 460 470 IEC 61215 2021 IEC61730 2016;UL61730 tuD 1 nit bllit EN13501Class" t Watt Class Sorting (W)^ A,: 0/+10` 0/+10 0/+10 IEC 062716 2 Ammonia Resistance^1 E ) o ' Nominal Power Voltage-VMPP(V) 54.3 54.9 55.4 J 61701` 5alf:,lylist(SM6) ^ Nominal Power Current IM (A) 8.29 8.38 8.49 IEC61215:2016 Hailstone(35mm) UL61730:`, FireType2", c F Open Circuit Voltage-Vec(V) 65.1 65.3 65.6 ISO 14001;1SO9001;IEC45001;IEC62941 to m Short Ctrcult Current I5C(Af 8 81 ;8:88 8 95' Power Density(W/ftz) 201 20.5 21.0 DVE .E�. � take lnray Ln Pane4Effidency(%) 21.6:^'; 22.1 22.6,. mtertek ak�w.°twEEE -.. _-. _ -. c mPhnt.cheme Power Output PMAx(WP)„ 343 ... 350 358 . -:. F- Nominal Power Voltage VMPP(V) 512 51.7 52.2 o z Nominal Power Current ,IM '(A) 670 6.77 686 Open Circuit Voltage-V°C(V) 613 61.6 118 7747 Short Circuit Current Isc(A) 711 7.17 7.23 Standard REC ProTrust Valuesat standard tes.conditions(STC:air mass AM 1.5,irradiancel000W/0,temperature 77F(25'C)).based onaproductm:isoreadw:thatoleranceof Pl,,yy..V�&Is,e3% ._ within one watt class Nominal module operatingtemperature(NMOT:air mass AM I.S.irradiance 800W/m2,temperature 68'F(20°Cl.w•,ndspeed3.3 ft/s(i m/,)).'Wherexxx Installed fiy�an REC T N0, :Yes ''Yes , indlcotes the nomma'.power class(P„sy)at STe above. 'Certified Professional �XMM�IN System Size.. All ¢SkVJ 25-500 kW.. ,E�, � a t roduct Warren rs 20: 25 25 ' DperattonalTemperature 40 F-18S*F Nominal Module Operating + 44°C 2°C P ty{y, ) System Voltage l OQO V Temperature arranty(yrs) 25 25 25 +7000Pa 14616 ft2 ""° LaboFWafrarrty(yrs)., 0' "'25 ` 10 N Maximum Test Load(front) ( ) Temperature coefficient of PMax° 0:24/°/K, o 0 0 0 Maximum TestLoad(r`ear)",' -4000Pa(83,4;1b/ft2),' Temperature coefficient ofV°C 0.24%/K Power inYearl 98/° 98/° 98/ Ln Max Series Fuse Rating 25 A Temperature coefficient of I' 0.04%/K Annual Degradation- 0.25% _ 0.25% 0.25% It sc MaX'ReverseCurrent 25;P rhetempemturecoeffiCPnt tatedarelinearval.ies Power in Year 25 92% 92% 92% See installation manual for mounting instructions Design load=Testloaa/I.S(safelyfactor) >«aq+m 3^T'"'^R*TF ,,',� The REC ProTrust Warranty is only avaliable on panels purchased through an REC to [3E IUERY)NFORNIATION Ce•tified Solar The installer.Warranty conditions apply.See wWwrecgroup. O more details N Panels per Pallet 33 Ln o Panels 0er40 ft GP/high " 599(18 Pellets): ��tm- y a cube container ,. I G T B E3R - E Panels per 53 ft truck 792(24 Pallets) �' co Available from: Typical low irradiance performance of module atSTC: t w -- Irradiance(W/m') Founded in 1996,REC Group is an international pioneeringsolar energy company dedicated to empowering consumers with clean,affordable REC Solar PTE.LTD. •�,,,. solar power.As Solar's MostTrusted,REC is committed to high quality,innovation,and a low carbon footprint in the solar materials and solar 20Tuas South Ave.14 REC panels it manufactures.Headquartered In Norwaywith operational headquarters in Singapore,REC also has regional hubs in North America, Singapore 637312 e Europe,and Asia-Pacific. post@recgroup.com Data Sheet Enphase Networking EnvoyEnphase IQ The Enphase IQ Envoy"" corr7munications gateway delivers solar production and energy consumption data to Enphase Enlighten"'' monitoring and analysis software for comprehensive, remote maintenance and management of the Enphase IQ System. With integrated revenue grade production metering and optional consumption monitoring, Envoy IQ is the platform for total energy management and integrates with the Enphase Ensemble"Wand the Enphase IQ Battery"' Smart Enables web-based monitoring ENPHASE and control Bidirectional communications for remote upgrades •Supports power export limiting and zeroexport applications Simple • Easy system configuration using Enphase Installer Toolkit'mobile app • Flexible networking with wi-Fi, Ethernet,or cellular Reliable • Designed for installation indoors or outdoors • Five-year warranty CERTIFIED To learn more about Enphase offerings,visit enphase.com Enphase I Envoy MODEL PLUMBERS r GvnxIYFp vh as� pM'€24t,1' k rrriepthearrne l{aI(nQA`Env�oy/c 20 !ta nQro"5aR 4ro) rs' tr rate\@d. onert�Q/r rrMgrae om gaaw �4 e � 29 and Qptlonel cons ptlotm"�\\, � l -1 i��JGyr NSIT1o. • - ( / 4 s w.� ., ve20flrrtrn,PQusraedprcrtlu�3rQnT(currertttrarrsforr) z ACCESORIES(OrderSeperatefy) onnp asp;;<,obr� Cv,`pjlti��'�t� .� � �,� � , ��� � ~Pft�g anclrpl tnifustrral grtT a cellula t��cr�m wit data planfor syst� s up tg6�g °CSLLI�i�lt51»M M1� �bas�cE'LTE�� f yeah data pE;an�,,� �,��•,v,':mtQCQr uerxe���(Avaalala�e trr the USt�ad�,t��tcQ I'r�r�o`Rrco and 3�•US Virgr CEt��+IOD�M M1 ��� based L E-firlv1/5 year�da a-p"t ) � 1 and���here there Is�`ad�quate c filar s±yYv[ce rn�t�ernstallaCro��rea) � " � - Consumption Monitoring CT Spfit-core consumption CTs enable whole home metering. CT-200-SPLIT arise iblecrmmu``catioria'{ ir „N tnstllcf at � '7Q Envo �r QQmmaucatiflnsr;flrnphase rr rge" torac'� S ICIT b1'' y andnplasr pone mart swrtllnclud USB cdbe for brtectEQn to 1Q � � �� �:.a„��� sx .m��. '�. � �,11'd'IWnpOw�� .?<.g� � ''' ,���,���.. �. �.:�.'\�'�,��.� •.�� � .;*�� POKER REQUIREMENTS Ie re r�lremf_. Typical Power Consumption 5U� CAPACITY MECHANICAL�DATA Drensrons�WXC}) � y \ T 1 �u r6 X 4 Gm 4C �,a. ate\:ti.. >.. ..>•s� ; = 2.K \. _--._.a. Weight 17,6 oz(498 g) gmw Abiq ttamperatbte range, �� , _ 40 to 65 { 0 to49 � t40°tt546 G40 to 115 rf rnsta;llerr;an enclosure Environmental rating \ IP30.For installation+indoors or in an NRTL-certified,NEMA type 3R enclosure. TflQrret �S6 J r 'r 644 - Ma's\ ��'i \� ,R Production CT Limited to 200A of continuous current/250A OCPD--72kW AC Internal aperture measures 19.36mm to support 250MCM THWN conductors(max) UL2808 certified for revenue grade metering ti a �; n \ flr efGtrlCa��B r ices tQ 25�1��fth parall rUr15 E[ O �iQl �h c3 G+�nsumiflnCT s / ��� li�ternal a�ertti`r�measli��4J 84':x 0 95`�"1 83mm�1�24 38,E in)to s�ip�port t� ��� � �e 'i\ ��ti= �` �� � t,�^,�'' UL�${�8 Cet"{fflG?d•f�Sr�uSe�t SerV1,G�EerrYratt�e�f0 6erV.iG�eS�Crp t0 25E0,��c �x� y„ INTERNET CONNECTION OPTIONS Itategrated WI F( �k 802,1 Ib/g Ethernet 802 3 Cat5E(or Cat 6)UTP Ethernet cable(not included) � Rtlo3at e Ala � � CELLMODEM=Mt (4+;)or CELLM ivf M B(4G fdat�nci ided h!1 that a rie, #pe 1'nb ile.�o')^[,eQ�ceafu14 n7b em is;requrredrfo,all Eraser ible InstaElaffons COMPLIANCE UL61Q`0 vCflftane ��M - E w8 ��v , v� �, w /1ECIEN 67010 12010, s�� W / EN500651,EIV61000 4 a,EN6100Q 61,Ei6100 Me erir ANSI. 12 20a Q�tracy class�.,5(PU prd. uctiol?or(y) To learn more about Enphase offerings,visit enphase.com 7.02t Fnpt phase F.r:.eryy.All rights.es%, Enp lase,;t e:Fnptiase logic,Q Envoy,and other traderrarks or service narr:.es are:the trade- marks of Enphase Energy,Inc..Data subject to charge.06 30-2021 ENPHASE. k k _r° � • -v�g r ; 4 ,„ ` ' +r2n §a'� to ti r x'"a ' f k e t y: � '�• a rr ,� M.7 d q•? ; i kt IQ8X Mier®inverter Easy to Install Our newest IQ8 Series Microinverters are the industry's first microgrid-forming',software-defined Lightweight and compact with plug microinverters with split-phase power conversion capability to convert DC power to AC power and play connectors efficiently.The brain of the semiconductor-based microinverter is our proprietary application- Power Ime„communicat ion. (PLC) specific integrated circuit(ASIC),which enables the microinverter to operate in grid-tied or between components off-grid mode.This chip is built using advanced 55-nm technology with high-speed digital logic Faster 1 btallatton v rlth simple two wire ME and superfast response times to changing loads and grid events,alleviating constraints on battery cabling sizingfor home energy systems. ' 9Y Y IQ8X Microinverter is the latest addition to this family,designed to support PV modules with high High produc#iwty and reltability output DC voltage and cell counts,such as 80-half-cut cells,88-half-cut cells and 96-cells. Produces poweC even when the grid is P 9 down* More than one mI ion cumulattve hours of testing h = Class II double insulated enclosure sf �3 Optimized for the latest high powered ,. M iii-..PVmocfules< _. Part of the Enphase Energy System, IQ8 Series Microinverters,redefine I08 Series Microinverters integrate with reliability standards with more than one MIdrogrld fo.mrng the IQ Battery,IQ Gateway,and the million cumulative hours of power-on Complies with the latest advanced grid Enphase App monitoring and analysis testing,enabling an industry-leading support software, limited warranty of up to 25 years. Remote automatic tipdates,for the latest grid'requlremellts Configurable to support a wide range ` s "' � � of grid profiles a' Meets CA Rule 21(UL 1741 SA)and IEEE „1547 2018`(UL 1741.SB) Connect PV modules quickly and easily IQ8 Series Microinverters are UL Listed „loeSeries%n coinverterseannotberrzedwth to the IQ8 Series Microinverters with as PV rapid shutdown equipment and previousgenerationsof Enphase microinverters(107 integrated MC4connectors. conform with regulations when installed Series I065ertes and soonlinthesainesystem according to the manufacturer's IQ Microinverters ship witlidefauI settings that Instructions. me6t N6rth America s IEEE 1547 interconnection standard iequfr'emonts:Regien spec(fic. ad'ustmehts may berequestedby an Authority Having Jurisdiction(AHJ)o�utihtyxrepresentat roe according to the IEEE 7547 interconnection *Meats UL 1741 only when installed with IQ System Controller 2 or 3. standard Ad IQ Gatewayis regwred to makethese' changes during installation: r. 0 2024 Enphase Energy.All rights reserved.Enphase,the a and CC logos,la and certain other marks listed at https;//onphaso;com/trademark=usago-guidolinos are trademarks of Enphase Energy,Inc.in the U.S.and other countries. Data subject to change. IQ8X-MC4-DSH-00185-3.o-EN-US-2024-02-12 IQ8X Microinverter RPM Commonly used module palrmgs! :r w s 320=540 Module compatibility _ To meet compatibility,PV modules must be within the following maximum input DC voltage and maximum module I., Module compatibility can be checked at htt s://en hase.com/installers/microinverters/calculator 4 MP PT voltage range .., V - " 3-60 Operating range V 25-79.5 Minimum and'maximum'sfart voltage V - `• 30='79.5 Maximum input DC voltage V 79.5 Maximum continuous operating DC current A 10, rrtu Maximum input DC short-circuit current A 16 Maximum module I, A 13; Overvoltage class DC port - II DC it backfeed current MA.- PV array configuration _ Ungrounded array;no additional DC side protection required;AC side protection requires a maximum of 20 A per branch circuit 'dumlr is :r i r: :r r: Peak outpuIt power VA: 384 Maximum continuous output power VA 380 360 Nominal grid voltage(L-L) V 240 split-phase(L-L),160 208;single-Phase(L-L);120°° Minimum and maximum grid voltage l V 211-264 183-229 , 133 , s output current 1.58. - A- Max:continuou _, Nominal frequency Hz 60 Extended frequency range - - - " Hz'- - : 4768 ' AC short circuit fault current over three cycles Arms 2.70 Maximum'units per 20 A,(L L)branch circuits i 10 ga. Total harmonic distortion % `5 e"rvoltag a class AC port Ov AC port backfeed current mA 18 Powerfactorsettmg , - r 1.0 Grid-tied power factor(adjustable) - 0.85 leading...0.85 lagging Peak efficiency / 973 CEO weighted efficiency % 96.5 96.5 on m Nighttime ower con supi ` 2 i Ambient temperature range 40 C to`65 C(-40°F to 149°F) Relative humidity range 4%to 100%(condensing) DC connector type Staubli M64 Dimensions(H x W D);Weight 212 mm(8.3")•175 mm(6.9").30.2 mm(1.2");1.1 kg(2.43 lb) Cooimg Natural convectlon nci an§ Approved for wet locations;Pollution degree Yes;PD3 Enclosure -, '° Classli double-insulated;corrosion,-resistant polymeNc enclosure _ Environmental category;UV exposure rating NEMA Type 6;outdoor r CA Rule 21(IJL 1741 SA) UL 62109-1,IEEE 1547 2018(UL 7741 SB)FCC Part 15'Class B,ICES 0003 Class B,CANIGSA-G22.2N0:1071 01. Certifications" 1 Thls product is UL Listed'as PV rapid shutdown equipment and conforms`with NEC 2014 NEC 2017.NEC 2020,and NEC 2023 section 690.12 and ... C22,1-2018 Rule 64r218:rapid shutdown of PV"systems#or AC and DC conductorswheninstalled according to the mariufacturerIsinstructions. (1)No enforced DC/AC ratio. (2)Nominal voltage range can be extended beyond nominal if required by the utility. (3)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. (4)1Q8X is not certified for use with Enphase Three Phase Network Protection Relay(NPR-3P-208-NA)and Is,therefore,designed I�SX-MC4-DSH-00185-3.0-EN-US-2024-02-12 for single-phase operation only.Check with the local utility requirements if you wish to Install single-phase inverters across three phases. c AIO& IRON RIDGE XR Rail° Family Solarunn Over their lifetime, solar panels experience countless " extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. XR Rails@ are the structural backbone t preventing-these results. They resist uplift, protect against buckling and safely " and efficiently transfer loads into the building structure. Their superior spanning capability requires fewer Af � roof attachments, reducing the J "RIK MR number of roof penetrations and the amount of installation time. "w k ^Po o RM qs u r z U Q E ">A,a�' �Y Force-Stabilizing Curve Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist.The curved shape of XR Rails@ x is specially designed to increase strength in both r directions while resisting the twisting.This unique feature ensures greater security during extreme �$ ? weather and a longer system lifetime. a Fir + 1"V, kYr " 4F" rca ��" G- �rrvrmt e; eq�rrr hr r a a r1� . .. _ __. .. .. _..__:..._. ... . .. ........:.:............ _. .., _.. ...___.__._ . . .. . . _.. .... Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials XR Rails®are ,` } ,z.: Iron Ridges offers All XR Rails@ are made of 6000-series compatible with a range of tilt leg aluminum alloy,then protected with an FlashFoot@ and options for flat anodized finish.Anodizing prevents surface other pitched roof roof mounting and structural corrosion,while also providing attachments. z.,; ,,,,k„ , :> applications. a more attractive appearance. s �� Wa'a � ; a / `r J XR Rail° Family The XR Rail®Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR RailO to match. F•' d§ J r XR10 XR100 XR1000 XR10 is a sleek,low-profile mounting XR100 is a residential and commercial XR1000 is a heavyweight among rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails.It's built to handle no snow.It achieves spans up to 6 feet, wind and snow conditions,while also extreme climates and spans up to 12 while remaining light and economical. maximizing spans up to 10 feet. feet for commercial applications. • 6'spanning capability 10'spanning capability 12'spanning capability • Moderate load capability Heavy load capability Extreme load capability • Clear&black anodized finish Clear&black anodized finish Clear anodized finish • Internal splices available Internal splices available Internal splices available Rail Selection The table below was prepared in compliance with applicable engineering codes and standards.* Values are based on the following criteria:ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 & 2e, Exposure B, Roof Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. i t k y ,>& m n•S� 90 sY YiE t�� n 8 ? aE EE' f €h€P9 q 'F"b.sa'r� l �qWYYYYY 3 ` ' 6 120 None 140 XR10 , Ogg F100 N M,_. Ilk 160 90 Y get xsz� d i 120 204q itWU d ' � s 140 try 160 f z sa 90 30 160 u 90 40 160 ' ^� 80 160 120 160 Table is rnemnt to be a;;irnpl€i.ed span chart For conveying general rail capabilities.Use approved certification,let er..for actual do s a t guidance, x a,.: i 4 • �. I R 0 N R I D G E XR1000 Rail /r See Descr�ption / Length Rail Section.Properties Property Value Total Cross-Sectional Area 0,582 in .66 Section Modulus (X-axis) 0.297 in' .46 Moment of Inertia (X-axis) 0:390 it 4 Moment of Inertia (Y-a)is) 0.085 in" rp9- Torsional Constant 0.214 in' Polar Moment of Inertia 0.126 it A 1.99 APPROVED MATERIALS: 2.44 6005-T6, 6005A-T61, 6105-T5, 6N01-T6 2.34 (34,000 PSI YIELD STRENGTH MINIMUM) .58 ........................................._..........._........................_........_....... �— 1.25— Clear Part Black Part Description/Length Material Weight Number Number XR-100-132A XR-100-132B XR100, Rail 132"(11 Feet) 6000-Series 7.50 lbs. XR-100-168A XR-100-168B XR100, Rail 168"(14 Feet) Aluminum 9.55 lbs. XR-100-204A XR-100-204B XR100, Rail 204"(17 Feet) 11.60 lbs. V1.11 r+u. Pacifico Engineering PC -. Engineering Consulting 700 Lakeland Ave, Suite 2B Ph: 631-988-0000 Bohemia, NY 11716 ] G c solar@pacificoengineering.com February 5,2025 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for LUCKYFRONT LLC 38015 Main Road Orient, NY 11957 1 have reviewed the roofing structure at the subject address.The structure can support the additional weight of the roof mounted system.The units are to be installed in accordance with the manufacturer's installation instructions. I have determined that the installation will meet the requirements of the 2020 Residential Code of New York State and ASCE 7-16 when installed in accordance with the manufacturer's instructions. Roof Section A B Mean roof height 22.0 ft 22.0 ft Pitch 1 degrees 1 degrees Roof rafter 11-7/8"TJ 1230 11-7/8"TJ 1230 Rafter spacing 16 inch on center 16 inch on center Reflected roof rafter span 19.3 ft 19.3 ft Rafter span max allowable 25.0 ft 25.0 ft V`\ EcoFasten ECO-65 w/ EcoFasten ECO-65 w/ (2)#14-13 x 5"DP1 (2)#14-13 x 5"DP1 v Fastener Type screws into rafter and screws into rafter and (6)#14-13 x 3"DP1 (6)#14-13 x 3"DP1 O� screws into sheathing screws into sheathing f' Allowable Fastener Capability 2125 Ib 2125 1b \ `� Fastener Spacing,Zone 1 /2/3 64/32/48 in 64/32/48 in Point Pullout, lb,Zone 1 /2/3 243/145/217 lb 243/145/217 lb Zone Category 1 /2/3 1 /2/3 1 /2/3 Uplift Pressure Zone 1 /2/3 16/19/19 psf 16/19/19 psf Exposure Category B Ground Snow Load, Pg 20 psf Wind Speed, 3 sec gust 130 mph array dead load 3.5 psf load per attachment 53.2 lb ,`@. \N PA C �� g The subject roof has 1 layer of roofing. C-) Panels mounted flush to roof no higher than 6 inches above roof surface. Ralph Pacifico, PE Professional Engineer Pacifico Engineering P.C. R ��� I h r Certificate#0018074 N i7 8 GREENLOGIC® ENERGY GreenLogic,LLC Approved LUCKYFRONT LLC 38015 Main Road o Orient,NY 11957 N = Surface#A: f'n co `?" Total System Size:29.900kW =� Array Size: 16.100kW U fir,; 1 circuit of 7 on a 20A breaker Lu C' 1 circuit of 9 on a 20A breaker(2x) 1 1 circuit of 10 on a 20A breaker P Azimuth: 100° Pitch: 1° Monitoring System: EnPhase Panel/Array Specifications: Panel:REC460AA PURE-RX Racking: IronRidge Panel:68.0"X 47.4" Array:47'8 7/8"X 17'3/4" Surface:50'9"X 20'1" Legend: ® 35 REC Alpha Pure-RX 460W 35 IQ8X Microlnverters Iron Ridge XR-100 Racking • 74 Eco-Fasten Fast Feet AN 8 8 TJI 230 x 12"Rafter 16"O.C. Notes: Number of Roof Layers: 1 ZFI; 4744 74 Z 7; ;,/X\/X\ Height above Roof Surface:4" Materials Used:Eco-Fasten, IronRidge, REC,EnPhase Added Roof load of PV System:2.32psf Engineer/Architect Seal: ®'C; NE�J � f � 2 • F'01PROFE55�0 Drawn By:MA Drawing#1 of 8 Date: 1/21/2025 REV:A Drawing Scale: 1/8"=1.0' GREENL®GIC® ENERGY GreenLogic,LLC Approved LUCKYFRONT LLC 38015 Main Road Orient,NY 11957 Surface#A: Total System Size:29.900kW Array Size: 16.100kW 1 circuit of 7 on a 20A breaker 1 circuit of 9 on a 20A breaker(2x) 1 circuit of 10 on a 20A breaker Azimuth: 100° Pitch: 1 Monitoring System: z EnPhase Panel/Array Specifications: Panel:REC460AA PURE-RX Racking:IronRidge Panel:68.0"X 47.4" Array:47'8 7/8"X 17'3/4" Surface:50'9"X 20'1" Legend: ® 35 REC Alpha Pure-RX 460W 35 IQBX Microlnverters ® Iron Ridge XR-100 Racking .77 • 74 Eco-Fasten Fast Feet 8 0 TJI 230 x 12"Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Eco-Fasten, IronRidge, REC, EnPhase Added Roof load of PV System:2.32psf Engineer/Architect Seal: 6, �QH PA F� ®,per / C'® `rF®� 0661 2 ®�ESSIO���' Drawn By:MA Drawing#2 of 8 Date: 1/21/2025 REV:A Drawing Scale: 1/8"=1.0' GREENLOGIC®_ ENERGY GreenLogic,LLC Approved LUCKYFRONT LLC 38015 Main Road Orient,NY 11957 Surface#A: Total System Size:29.900kW Array Size: 16.100kW 1 circuit of 7 on a 20A breaker 1 circuit of 9 on a 20A breaker(2x) 1 circuit of 10 on a 20A breaker Azimuth: 100' Pitch: 1° Monitoring System: z EnPhase Panel/Array Specifications: Panel:REC460AA PURE-RX Racking:IronRidge 1 2 Panel:68.0"X 47.4" Array:47'8 7/8"X 17'3/4" Surface:50'9"X 20'1" Legend: 1 3 ® 35 REC Alpha Pure-RX 460W 35 IQ8X Microlnverters Iron Ridge XR-100 Racking • 74 Eco-Fasten Fast Feet 8 8 TJI 230 x 12"Rafter 16"O.C. 1 4 Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used:Eco-Fasten, IronRidge, REC,EnPhase Added Roof load of PV System:2.32psf Engineer/Architect Seal: OF NEW PAC�,�ic��� BOA 066162 SSIO����� Drawn By:MA Drawing#3 of 8 Date: 1/21/2025 1 REV:A Drawing Scale: 1/8"=1.0' GREENLOGIC®. ENERGY GreenLogic,LLC Approved LUCKYFRONT LLC 38015 Main Road Orient, NY 11957 Surface#B: Total System Size:29.900kW Array Size: 13.800kW 1 circuit of 10 on a 20A breaker(3x) Azimuth: 100° Pitch: 1 Monitoring System: z EnPhase Panel/Array Specifications: ° Panel: REC460AA PURE-RX Racking: IronRidge Panel:68.0"X 47.4" Array:51'8 3/4"X 18'10 3/8" ° Surface:55'X 20'1" Legend: ® 30 REC Alpha Pure-RX 460W 30 IQ8X Microlnverters 74 ® Iron Ridge XR-100 Racking • 65 Eco-Fasten Fast Feet B 8 TJI 230 x 12"Rafter 16"O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used:Eco-Fasten,IronRidge, REC, EnPhase Added Roof load of PV System:2.32psf Engineer/Architect Seal: O �L 066182 SS10� Drawn By:MA Drawing#4 of 8 Date: 1/21/2025 REV:A Drawing Scale: 1/8"=1.0' GREENLOGIC®- ENERGY GreenLogic,LLC Approved LUCKYFRONT LLC 38015 Main Road Orient, NY 11957 Surface#B: Total System Size:29.900kW Array Size: 13.800kW 1 circuit of 10 on a 20A breaker(3x) Azimuth: 100' Pitch:1' Monitoring System: z EnPhase Panel/Array Specifications: Panel:REC460AA PURE-RX Racking: IronRidge Panel:68.0"X 47.4" R -X Array:51'8 3/4"X 18'10 3/8" Surface:55'X 20'1" Legend: ® 30 REC Alpha Pure-RX 460W 30 IQBX Microlnverters —\Z A I Iron Ridge XR-100 Racking 7' P> Al • 65 Eco-Fasten Fast Feet dB TJI 230 x 12"Rafter 16"O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used:Eco-Fasten, IronRidge, REC,EnPhase Added Roof load of PV System:2.32psf Engineer/Architect Seal: QF Nf WPAC y� eR�1 S bssi s ®� ®FESS10��� Drawn By:MA Drawing#5 of 8 Date:1/21/2025 REV:A Drawing Scale: 1/8"=1.0' GREENLOGIC® ENERGY GreenLogic,LLC Approved LUCKYFRONT LLC 38015 Main Road Orient,NY 11957 Surface#B: Total System Size:29.900kW Array Size: 13.800kW 1 circuit of 10 on a 20A breaker(3x) Azimuth: 100' Pitch: 1' Monitoring System: Z EnPhase Panel/Array Specifications: ° Panel:REC460AA PURE-RX 5 ° Racking:IronRidge Panel:68.0"X 47.4" X _ x 6 7 Array:51'8 3/4"X 18'10 3/8" x x ° Surface:55'X 20'1" _X Legend: 5 6 ® 30 REC Alpha Pure- 5 460W 7 6 7 30 IQ8X Microlnverters x x ® Iron Ridge XR-100 Racking • 65 Eco-Fasten Fast Feet __x5 8 8 TJI 230 x 12"Rafter 16"O.C. _T7F Notes: X7 Number of Roof Layers:1 5 Height above Roof Surface:4" ° ° Materials Used: Eco-Fasten, IronRidge, REC,EnPhase Added Roof load of PV System:2.32psf Engineer/Architect Seal: PAC;,���o�' F s f, 666182 Drawn By:MA Drawing#6 of 8 Date: 1/21/2025 REV:A Drawing Scale: 1/8"=1.0' No Vent Pipes Will Be Covered By The Solar Array C*GREENLOGIC®� ENERGY Legend: GreenLogic,LLC Approved LUCKYFRONT LLC AR-Access Roof AP-Access pathway, 36" minimum width SVO—Setback at ridge 38015 Main Road per R202 definitions per R324.6.1 as per R324.6.2.1 orient, NY 11957 Total System Size:29.900kW 1 circuit of 7 on a 20A breaker 1 circuit of 9 on a 20A breaker(4x) 1 circuit of 10 on a 20A breaker(4x) Azimuth: 190° Monitoring System: N EnPhase Panel/Array Specifications: Panel: REC460AA PURE-RX Racking: IronRidge Panel:68.0"X 47.4" Wi Surface: 139'3"X 74'2" Legend: ® 65 REC Alpha Pure-RX 460W 65 IQ8X Microlnverters Iron Ridge XR-100 Racking • 139 Eco-Fasten Fast Feet 0 8 TJI 230 x 12"Rafter 16"O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used:Eco-Fasten, IronRidge, REC, EnPhase Added Roof load of PV System:2.32psf 35 REC 460W .`�� PA0%,� � Panels ��@ 0 30 REC 460W Panels 1 06618'2 SSI®��� - Meter / Drawn By:MA Drawing#7 of 8 d Date: 1/21/2025 REV:A Drawing Scale:3/64"=1.0' GREENL®GIC® ENERGY GreenLogic,LLC Approved LUCKYFRONT LLC 38015 Main Road Orient,NY 11957 Total System Size:29.900kW 1 circuit of 7 on a 20A breaker 1 circuit of 9 on a 20A breaker(4x) 1 circuit of 10 on a 20A breaker(4x) - - - - - - - - —-- - - - -..._. -------- - - - - Azim uth: JOB MATERIAL LIST N Monitoring System: - . . - - - --- _...- - -.. =----- - - -- ...------ ------- - - EnPhase Panel/Array Specifications: _ Panel: REC460AA PURE-RX Racking: IronRidge -- Panel:68.0 X 47. "4 Material List � - Rail Material List - ktt- Surface: 139'3"X 74'2" Legend: Eco-Fasten "Fast Feet" Base Plate 139 Alpha Pure-RX 60W - ----- --- -- - --- - -�� --- - - - - - - _ - ; ---- - -- - - - - ', - ® X Microlnverters 4 65 REC Eco-Fasten "Fast Feet Aluminum Block 139 65 IO8 Eco-Fasten "Fast Feet" EPDM Flashing 139 Iron Ridge XR-100 Racking -- - --- - - - - - - - • 139Eco- as en Fast F t Feet #14-13x5"DPI Concealer Screw 278 8 8 TJI 230 x 12"Rafter 16"O.C. #14-13x3"DPI Concealer Screw 834 I Notes: Number of Roof Layers: 1 Height above Roof Surface:4" - Materials Used:Eco-Fasten, IronRidge, REC,EnPhase Added Roof load of PV System:2.32psf Enginee hitect Seal: rn� V -ZIP 066182- -- FESS��� Drawn By:MA Drawing#8 of 8 Date: 1/21/2025 REV:A Drawing Scale:3/64"=1.0'