Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
52632-Z
,�pf SOlo/Tyo`o Town of Southold * * P.O. Bog 1179 a� 53095 Main Rd Ntr,' Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 47329 Date: 08/28/2026 THIS CERTIFIES that the building SINGLE FAMILY DWELLING-ALTERATION Location of Property: 1400 Track Ave Cutchoaue, NY 11935 Sec/Block/Lot: 137.-2-3 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 12/03/2025 Pursuant to which Building Permit No. 52632 and dated: 01/27/2026 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Interior alterations and "as built" alterations including a partial conversion of an existing attached garage to laundry room & bathroom as applied for. The certificate is issued to: Andrew Oppenheimer ,Nicole Dobranski Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 52632 8/18/2026 PLUMBERS CERTIFICATION: Andrew Oppenheimer 8/17/2026 Au orize Signature �apFSOUTyO TOWN OF SOUTHOLD BUILDING DEPARTMENT • �� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52632 Date: 01/27/2026 Permission is hereby granted to: Sandra Simchick PO BOX 405 Cutchogue, NY 11935 To: legalize "as built"alterations and to construct new alterations to an existing single-family dwelling as applied for. Additional certification will be required. Premises Located at: 1400 Track Ave, Cutchogue, NY 11935 SCTM# 137.-2-3 Pursuant to application dated 12/03/2025 and approved by the Building Inspector. To expire on 01/27/2028. Contractors: Required Inspections: Fees: Single Family Dwelling- Alteration $307.50 As Built Alteration $84.00 CO-RESIDENTIAL $100.00 Total $491.50 --- — --------------------- Building Inspector SO(/jyO Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O. Box 1179 �oQ Southold,New York 11971-0959 c01+JNT1,� ► BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Sandra Simchik Address: 1400 Track Ave city: Cutchogue St: NY zip: 11935 Building Permit#: 52632 Section: 137 Block: 2 Lot: 3 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Electrician: Carpio Electric License No: 71546ME SITE DETAILS Office Use Only Commercial Indoor X Basement X Service X Solar Residential X Outdoor X 1st Floor X Pool Battery Storage As-built X Renovation 2nd Floor Hot Tub EV Charger New Addition Attic Spa Generator Survey Mezzanine Garage Dock INVENTORY Service 1 ph X In-wall Heater Recpt 1.6 Ceiling Fixtures 12 Smoke Detectors 3 Pump Service 3 ph Hot Water GFCI Recpt 2 Wall Fixtures 1 CO Detectors Heater Main Panel 200 A/C Condenser Single Recpt RecessdFixtures 12 Combo Smoke/CO 2 Transformer Meter Main 200 A/C Blower Range Recpt 50A Ceiling Fan Heat Detectors Salt Gen Transfer Switch Mini Split 1 Dryer Recpt 30A UC Lights 18' Fridge 1 AutoCover ARC 4 Blower Heads Switches 13 Pucks Lights 2 Dishwasher 1 Mini Fridge GFI 1 SepticDisconnect Emrgency Strobe 4'LED Microwave 1 Garbage Disp. ARC/GFI 10 ERV Exit Lights Bath Exhaust Hood 1 Dehumidifier Other Equipment: 200A Panel 40 Circuit/35 Used Notes: "AS Built No Visual Defects" Kitchen, Service, AS BUILT LAUNDRY & BATH C Inspector Signature: Date: August 18, 2026 lcz- �z 6 7-1�z I c)a * # lvWN OF SOUTHOLD BUILDING DEPT. `ycooMv, 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ]. RENTAL REMARKS: DATE INSPECTOR OFSOUTy�Io 5 2 6 52,- * # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) %ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR hO�aOF 50b1�O� # TOWN OF SOUTHOLD. BUILDING -DEFT. 631-765-1802 .A-INSPECTION [ ] FOUNDATION 1 ST/REBAR [ ] ROUGH PLBG. [ ] . FOUNDATION 2ND [ ] I LATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE &.CHIMNEY [ ] FIRE SAFETY INSPECTION [ ]. FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT.PENETRATION ]r ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: t/u/ (1- k- "'Z MAIO ) Zecv� KI DATE INSPECTOR cot Town Hall Annex ;.r'��� C���:; Telephone(631)765-1802 54375 Main Road P. O. Box 11791 erg Southold, NY 11971-0959 1 ' ` AUG 1 7 2026 ,. BUILDING DEPARTMENT Building Department TOWN OF SOUTHOLD Town of Southold CERTIFICATION Date: Building Permit No. �- Owner: ;�r�� (Please print) Plumber: �— (Please print) Lo\.� -) I certify that the solder used in the water supply system contains less than 2/10 of 1%lead. C s Signature) p, OWn.'r Sworn to before me this '-' 1 CONNIE D.BUNCH Notary Public,State of New York day of 204 No.01BU6185050 Qualified in Suffolk County.0 (� 1 Commission Expires April 14,2 Notary Public, County 1 FIELD INSPECTION REPORT DATE COMMENTS C h m FOUNDATION (1ST) ------------------------------------- FOUNDATION (2ND) z 0 G ROUGH FRAMING& PLUMBING N 11J r INSULATION PER N.Y. STATE ENERGY CODE Wt FINAL ADDITIONAL COMMENTS ` 3 y 2c� Pa�AI B.� t cd sec-# l 7 � � z tri z - x d b �o�oSUFFatr�oG� TOWN OF SOUTHOLD—BUILDING DEPARTMENT V Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 g: �. Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny_gov y�o! gaol., Date Received APPLICATION FOR BUILDING PERMIT l,tl 6 L 1uI L \ _ For Office Use only PERMIT N0. Building Inspector: t DEC — 2025 �.. a Applications and forms must be filled out in their entirety. Incompletef applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date:11/26/2025 OWNER(S) OF PROPERTY: Name:Andrew Oppenheimer & Nicole Dobranski SCTM #1000-137-2-3 Project Address:1400 Track Ave, CutChogue, NY 11935 Phone#:(516)084-2085 Email:1400track@gmail.com Mailing Address: CONTACT PERSON: Name:John McNeill - McNeill ArchitectureconbO Mailing Address:321 Riverside Drive, Riverhead, NY 11901 Phone#:(516)376-8594 Email:john@mcneillarchitecture.com DESIGN PROFESSIONAL INFORMATION: Name:John McNeill - McNeill Architecture Mailing Address:321 Riverside Drive, Riverhead, NY 11901 Phone#:(516)376-8594 Email:john@mcnei-Ilarchitecture.com CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: 20ther Legalization of 1st floor bathroom and laundry room and proposed kitchen renovation $20000 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes liNo 1 • L PROPERTY INFORMATION Existing use of property: Residential Intended use of property: Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to Residential this property? ❑Yes ®No IF YES, PROVIDE A COPY. 8 Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized Inspectors on premises and in buildingis)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By( ri t name):John McNeill BAuthorized Agent ❑Owner Signature of Applicant: Date: CONNIE D.BUNCH / Notary Public,State of New York STATE OF NEW YORK) No.01BU6185050 SS: Qualified in Suffolk County COUNTY OF ) Commission Expires April 14, 2-,� John McNeill, R.A. being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Agent / Architect (Contractor,Agent,Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this R day of 20�`� Notary Public �=�= PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) Andrew Oppenheimer residing at 1Vyv Tr-`'-/C &C . 64.-�GL14 .,(- N S' ri935 do hereby authorize John McNeill to apply on r my behalf to the Town of Southold Building Department for approval as described herein. i?,L2,Z 5 Owner's Sig ature Date A7J2-✓ Print Owner's Name 2 BUILDING DEPARTMENT- Electrical Inspector p�-Q cep' TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 r Southold, New York 11971-0959 41 • p`r ' Telephone (631) 765-1802 APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date. 6 Company Name: Q27W Co-N t ip dewcAi%c or— Electrician's Name: �, �`, yv1 00%6pI to c License No.: 1N\ -`11 S y� Elec email: `, �� `,c Elec. Phone No: (,3) �Irequest an email copy of Certific e of Compliance Elec. Address.: s`,1 cLv ��I JOB SITE INFORMATION (All Information Required) Name: Q W�2 WCP, Address: Nv v Cross Street: Phone No.: 63 k�Z �-b 1.l7 Bldg.Permit #: �2 62j2 email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): ) 'AdAev\ i"e►go A 1 'OF- 6 iQ Square Footage: S-CQ Circle All That Apply: Is job ready for inspection?: [0-YESE1 NO ©Rough In Final Do you need a Temp Certificate?: D YES [a-NO Issued On Temp Information: (All information required) Service Size❑1 Ph 03 Ph Size: A # Meters Old Meter# ❑New Service0 Fire ReconnectOFlood Reconnect[]Service Reconnect[]Underground DOverhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION 00 ('ems-*14 8tF3 loo BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 ":,y • or.: Telephone (631) 765-1802 APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: r7 6 Company Name: Co,( f, - Electrician's Name: �, �`,U v� Gar , C ke- License No.: ME `]1 S -I f, =st t, an email copy of Certific e of Compliance Elec. Phone No. 1, ( (�6 I Elec. Address.: j 5 s',1 ` JOB SITE INFORMATION (All Information Required) Name: QI � Address: Cross Street: Phone No.: 631 rqi�-Z rrry D Bldg.Permit #: 52 I7j5 email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): ov ��J Square Footage: Circle All That Apply: YES 0 NO ©Rough 1n El Final Is job ready for inspection?: Do you need a Temp Certificate?: F] YES �NO Issued On Temp Information: (All information required) Old Meter# Service Size❑1 Ph[]3 Ph Size: A # Meters _— []New Service[]Fire ReconnectOFlood Reconnect[]Service Reconnect oUndergroundQOverhead # Underground Laterals 1 2 D H Frame Pole Work.done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION PERMIT# Address: 1 Switches �/ Outlets/ GFI's �I Surface Sconces H H's l UC Lts Fridge HW POOL Fans Mini Fr.i W/D PanelPump 1 Exhaust Oven Sump Heater Trnsfmr Smokes �� DW Generator Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower " AC AH Hoo l 100 Blower Service Amps � Have Used , Sub Amps Have Used Comments K2 ? -- A0 GG S.C.T.M. NO. DISTRICT: 1000 SECTION: 137 BLOCK: 2 LOT(S):3 TRACK AVENUE EDGE OF PAVEMENT PIPE N 49001 '20" E 80.00 /MON. MON. Uj 0.2'E 0.4E 150.00'Qn to 1.3 S I r A ^ � O Imo/ O a S m ^ C z T' m coa -ccXm O z r Z 1771 n m z m x CN 11.4' CONC.PATIO X .1 STY FRM.%. m g 'DWELLING•:•';'.::'.':. H CONC.APRON GATE 1.2'E 000VERED m:::':20.6';:::..'.:: �.5'W PORCH o..:..:. :......... GARAGE Q o.•.•. ..•...'.':':: ::.' 10.3' c}- �x/ ...20.4':'::':::: 0.5'W 0.6'E STONE/BRICK GATE r_- Lr) PATIO POOL I I 0 I EQP. _ ---x-- --x-- — — 0.6'W A I STONE/BRICK ;: �,'•'•::: I �-.. = I PATIO ...••:•.��:•:.'.'. z z z n �Jl ~p Im U') I O O O I O I p 18.T J d X � I I 00 TIM ER WALL i LO. N 0.2'NXE 5'VINYL FENCE 0.9'W _ _ 6'POST/WIRE 0.1'S PIPE — S 50°42'20" W MOH. i 80.04' LAND N/F OF LAND N/F OF I LAND N/F OF TERRY BECKER i DORIS ANNABEL I JOANN PRINCE ROBERTANNABEL I ROBERTANNABEL VINCENTANNABEL THE WATER SUPPLY, WELLS, DRYWELLS AND CESSPOOL REVISED 08-20-25 LOCAT70NS SHOWN ARE FROM FIELD OBSERVA77ONS AND OR DATA OBTAINED FROM OTHERS. AREA: 13,552.36 SQ.FT, or 0.31 ACRES ELEVA77ON DATUM. _______________________ UNAUTHORIZED AL7ERA77ON OR ADD177ON TO THIS SURVEY IS A VIOLA77ON OF SEC77ON 7209 OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS SURVEY MAP NOT BEARING THE LAND SURVEYOR'S EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. GUARANTEES INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED AND ON HIS BEHALF TO THE 777LE COMPANY, GOVERNMENTAL AGENCY AND LENDING INS77TU77ON LISTED HEREON, AND TO THE ASSIGNEES OF 7HE LENDING.INST7TU770N, GUARANTEES ARE NOT TRANSFERABLE. THE OFFSETS OR DIMENSIONS SHOWN HEREON FROM THE PROPERTY LINES TO 77-IE STRUCTURES ARE FOR A SPECIFIC PURPOSE AND USE 7HEREFORE THEY ARE NOT INTENDED TO MONUMENT THE PROPERTY LINES OR TO GUIDE 7HE ERECTION OF FENCES, ADDITIONAL STRUCTURES OR AND 07HER IMPROVEMENTS. EASEMENTS AND/OR SUBSURFACE STRUfURES RECORDED OR UNRECORDED ARE NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT THE 77ME OF SURVEY SURVEY OF: LOT 53& P/O LOT 54 CERTIFIED TO: ANDREW OPPENHEIMER; MAP OF: M.S. HAND SECTION 2 NICOLE DOBRANSKI• FILED: MAY 12, 1939 No.1280 FIDELITY NATIONAL TITLE INSURANCE COMPANY; SITUATED AT: CUTCHOGUE TOWN OF: SOUTHOLD KENNETH M WOYCHUK LAND SURVEYING, PLLC SUFFOLK COUNTY, NEW YORK Professional Land Surveying and Design P.O. Box 153 Aquebogue, New York 11931 FILE #225-138 SCALE: 1"-20' DATE: AUG. 3, 2025 N.Y.S. L/SC. N0. 050882 PHONE (631)298-1588 FAX (631) 298-1588 4. s AP RO ED AS NOTED DATE- B.P. FEE r BY NOTIFY BUILDING DEPARTMENT AT 631-765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE t' 2. ROUGH-FRAMING&PLUMBING 3. INSULATION 4. FINAL-CONSTRUCTION MUST 321 RIVERSIDE DR BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE RIVERHEAD, NY 11901 REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR (516)376-8594 DESIGN OR CONSTRUCTON ERRORS PLUt4BER CERTIFICATION COMPLY WITH ALL CODES OF ON LEAD CONTENT BEFORE CERTIFICATE OF OCCUPANCY STILL WATER AVENUE NEW YORK STATE&TOWN CODES AS REQUIRE/ND DITIONS OF SOLDER USED IN WATER N ZBA SUPPLY-SYSTEM CAI ANC- EXCEED 2/10 OF 1% LEA Additional OCCUPANCY OR Certification 170.58 USE IS URLAV�TUL May Be required. M — V JTHOU T CER T I IC TE 6 6 0 0 OF OCCUPANCY 68.2' 21.8' I PLV",I"I'N10 ALL rLUM1111NIS�A'AgTC 82 R WATER LI"�E:; I!EI_U TESTINGPFFORrC' P? EIiPdC LEGALIZE EXISTING Y�.,l,.. Client Info DRIVEWAY BATHROOM AND ANDREW OPPENHEIMER& NICOLE N GARAGE o M 14.0' CmLAUNDRY ROOMDOBRANSKI 1400 Track Ave wCutchogue, NY 11935 s.0' 76.9' Project Info Z O o LEGALIZE EXISTING BATHROOM w O o I O AND LAUNDRY ROOM \ O. PROPOSED KITCHEN / CO 1400 Track Ave / OO _ INTERIOR ALTERATIONS I Cutchogue, NY 11935 29.1' IM U a Q ( EXISTING 1 N STORY FRAME DWELLING I 48.3' 40.9' 79.4' c cn o z o a v v in 'C U (iJ N tY � 168.231 N PLOT PLAN o SCALE: 3/32" = 1'-0" 6" DIAMETER pEDARC �~ O�ARD REFLECTIVE RED PANTONE#187 REFLECTIVE WHITE THIS PROJECT HAS BEEN DESIGNED IN ACCORDANCE WITH - CONSTRUCTION CHAPTER 8: ALTERATION - LEVEL 2 OF THE NEW YORK ra,� 03874 ���� TYPE OF N STATE EXISTING BUILDING CODE. 1/2" STROKE DESIGNATION FOR STRUCTURAL N. I .STATE CODE COMPLIANCE NOTE: COMPONENTS THAT ARE OF TRUSS TYPE CONSTRUCTION THIS PROJECT HAS BEEN DESIGNED IN ACCORDANCE WITH THE FOLLOWING CODES. PLOT PLAN BCNYS 602.5 TYPE V. CONSTRUCTION TYPE"F" FOR STRUCTURAL COMPONENTS See- PART 1265 RESIDENTIAL STRUCTURES WITH TRUSS TYPE CONSTRUCTION 2020 INTE��.ATIO1 BUILDING CODE PRE-ENGINEERED WOOD CONSTRUCTION,AND/OR TIMBER CONSTRUCTION 2020 INTERNATIONAL ENERGY CONSERVATION CODE Drawn By Checked By ALL NEW CONSTRUCTION OR MODIFICATION TO RESIDENTIAL DWELLINGS 2020 INTERN TONAL FIRE CODE INVOLVING TRUSS TYPE CONSTRUCTION,PRE-ENGINEERED WOOD 2020 INTERN A TONAL PLUMBING CODE •E•M• •E•M CONSTRUCTION AND/OR TIMBER CONSTRUCTION,HOMEOWNER IS REQUIRED BY 2020 INTERNONAL MECHANICAL CODE NEW YORK STATE LAW AND RCNYS TO AFFIX A DECAL SIGNALING TRUSS 2020 INTERN TI6NAL FUEL GAS CODE Drawing No. CONSTRUCTION HAS BEEN USED TO AN ELECTRICAL METER BOX OUTSIDE THE A-0 HOME. SPECIFICATIONS ATTACHED NFPA 70: N ION LELECTRIC CODE (NEC),2020 EDITION Sheet 1 of 5 4 57'-10" 57'-10" 20'-3" 37'-7" 20'-3" 37'-7" A A SKYLIGHT U� DRYER VENTED '6 0 1 \� TO EXTERIOR o 1 A I BATH W. DRY 1,%,RCXi ITECTU #, L'- 0 5'-11" — o co ��'� LAUNDRY 321 RIVERSIDE DR N v WHr. H.U. � 121_811 20'-7" RIVERHEAD, NY 11901 (516)376-8594 I I OVEN KITCHEN 2"x10" F.J._ W I 6'-8 1/2" �� _ 00 UP 16" O.C. ON o I N o 2x4 BEARING UP cr_ l N wAEE Cn N N I� LIVING ROOM `1 N 13'-8" co REF. v I N ,I ,I ,_ I� N I 9-2 1/2" 1-"31-1 1/2" 4 7 UP 13'-2 1/2" 11 11'-8 1/2" 11'-8" GARAGE ® ® CLOS. O co Fire separation required as per NYS Code _ M 0 w - o zo co CC 19T (D BEDROOM CV — — o _ xC14b N1 A A BATH N e @ SD ti ff _2"xl 0" F.J._ _2"x10" F.J._ @16" O.C. @16" O.C. @ SD Client Info I @ co ANDREW OPPENHEIMER& NICOLE CLOS. CLOS.o DOBRANSKI N 1400 Track Ave Cutchogue, NY 11935 N OIL TANK Q o @ SD Project Info @ SD LEGALIZE EXISTING BATHROOM AND LAUNDRY ROOM 1400 Track Ave BEDROOIA BEDROOM ; T Cutchogue, NY 11935 cN WELL EQUIP. 1 -v a� 0 10'-7 1/2" 2'-0" 10'-9" �- a Q 20'-3" 12'-10 1/2" 24'-8 1/2" 20'-3" 12'-10 1/2" 24'-8 1/2" ol Ir 57'-10" 57'-10" v) o lo z 0 BASEMENT FLOOR FLAN FIRST FLOOR PLAN SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" Leh.. y a;p { a • n Zs.' ` „`j >: y .q,.. ° aYR '- ++ EXIST.2 x8 C.J.I�(lil 16 O.C. 16. p R-25 BATT INSUL. Y ,� �•° .� ` 2'GYP.BD.(TYP.) � _: EXISTING ROOF SHIINGLES EXTERIOR PLYWOOD 2"X6"R.R. 16"O.C. � Y. � a r RED Ap f x a ATTIC R-19 BATT INSULATION ._ - >l ` ``� Y+I�Rp GYPSUM BOARD(TCP 'YP) . : 2 0 �r f - s .A{. y .'i 4 ,.:i;.-X$ wr'a� '°,,. « .W A, ',y w.J, g` fy°'•P"s. -'- 0 V CONSTRUCTION NOTES:` ' �: .. ALUMINUM GUTTER I>� � i� R � 1"FASCIA TRIM ": ." e:: ; �• "' ;' : "' .: ti` . i, # FOR COMPRESSIVE STRENGTH OF " " D 16"O.C. SOFFIT :. 9�` oa a'r CONCRETE SEE TABLE IR402.2 ON 2x4 STUDS S @ VENT ' • x _ t - 77 N C> R-13 BATT. INSULATION "" a �' "' "<" . F ' (�j+g7 •—� J`! `Ate y. ..+ ,. {{ 4' /— h4Y,1j-'1 LEGEND EXISTING SIDING AiND SHEATHING ! L 1/2"GYPSUM BOARD ANY/ALL LUMBER THAT COMES �, = 2"x4"STUDS @ 16" O.C. ;;,�„ 5 { 4 s: . •, INTO CONTACT WITH CONCRETE BATH R-13 BATT. INSULAkTION SHALL BE ACQ NEW FOUNDATION o °O 1/2"GYPSUM BOARZD SEE DETAILS ... ALL CORNERS �� RAMING GARAGE TO BE CONTIN�C9'� RAP DOWN NEW INTERIOR 3/4 PLYWOOD _4;� FLOOR PLANS & WITHIN A MIN. OF 10%OF THE LEAST WALL&PARTITION 2"x8"FLR.JST.@116"O.C. `^y# ' x HORIZONTAL DIMENSION R-19 BATT INSULATION TYP.) � �` SECTION TO NEW EXTERIOR � :.., • COLLAR TIES TO LOCATED IN THE WALL ,n. LEGALIZE BATH AND UPPER 1/3 RD OF THE ATTIC NEW WINDOW « w BATH WINDOW TO CONFORM LAUNDRY ROOM TO THE HAZARDOUS GLAZING REQUIREMENTS AS PER SECTION 308.4 E NEWYORK STATE RES. CODE. NEW Drawn By Checked By OF THE O J.E.M. J.E.M. TEMPERED GLASS REQUIRED AT AGE OF BATHROOM AND LAUNDRY ROOM IS UNKNOWN. GLASS OPENINGS WITHIN 18"AFF O SD HARDWIRE ORSMOKE SECTION A-A APPEARS TO BE PRIOR TO 2000. RENOVATION Drawing No. zv S. L: uu BLOCK UNDERSIDE OF NON-BEARING HAPPENED WITHIN THE EXISTING THERMAL ENVELOPE. INTERIOR WALLS RUNNING PARALLEL O CO CARBON MONOXIDE SCALE: 1/4" = 1'-0" A- 1 W/FLOOR JOIST. II DETECTOR Sheet 2 of n a e l r t� f I i i tA SKYLIGHT TA 101-8" 1%R IT �a loe DRYER VENTED 7I ( 0 1 DRYER VENTED 321 RIVERSIDE DR I \ / I \ I TO EXTERIOR � TO EXTERIOR R I V E R H EAD, NY 11901 BATH W. DRY - W. DRY 0 _ = = = = e BAT ' (516)376-8594 5-11 0 5 11 6`8�/2 2�'� LAUNDRY LAUNDRY MICROLAM LVLIHEADER it 6'-0"x6'-8"SLIDING DOOR 12'-8" I I 20'-7" WITH SIDELIGHTS CLOS. 6'-3 1/2" DN — CLOS. 6'-3 1/2" DN OVEN I KITCHEN REF. 6'-8 1/2" I ao �� N o 13'-8" II N LIVING ROOM LIVING ROOM `.' 13'-8" - — I i Cam coJ® 1 REF. I I I 1 9'-2 1/2" ¶ 3'-1 1/2" 4'-7" _ KITCHEN 1 1 Ov. I I I F- __= c� 4'-10'� 5�_0 GARAGE GARAGE I I co n (3)1-314"x7-1/4 CLOS. I I M I I LO I " �f U - - - - MICROLAM LVL(UPSET) OC9 O 00 P 44 POST TO \ O - 19-711 FOUND. BELOW N v O 44 POST To -c�,'� _ �.. w v BEAM BELOW 0 o M m 2'-0" 11 BEDROOM COVERED BEDROOM c, PORCH Client Info 9'-611 3'-11/2" 10'-9" CD g_6" 3'-11/2" 10'-9" ANDREW OPPENHEIMER & NI COLE qq A BATH N e SD A BATH CV e SD DOBRANSKI ti ff F_ EF 1400 Track Ave Q SD Q SD Cutchogue, NY 11935 C: I Qco Qco CLOS. CLOS. CLOS. CLOS. o Project Info N N LEGALIZE EXISTING BATHROOM - - AND LAUNDRY ROOM 1400 Track Ave Cutchogue, NY 11935 Q SD Q SD LF Q SD Q SD N O BEDROOM - BEDROOM ti BEDROOM ti a BEDROOM7 CL N N Q 10'-7 1/2" 2'-0" 10'-9" 10'-7 1/2" 2'-0" 1 e 10'-9" o FIRST FLOOR DEMOLITION PLAN FIRST FLOOR PLAN - OPTION 4 Z o SCALE: 1/4" = 1'-0" •°- SCALE: 1/4" = 1'-0" >N L Jo N � o a� v 0 ,F9,ED Apt 90ARD CONSTRUCTION NOTE S: FOR COMPRESSIVE STRENGTH OF - 4• CONCRETE SEE TABLE R4'02.2 ON � �c�'�o����••t4 LEGEND ANY 1 ALL LUMBER THAT COMES INTO CONTACT WITH CONCRETE SHALL BE ACQ NEW FOUNDATION SEE DETAILS ALL TO E�ON TN� R/PMING DOWN NEW INTERIOR FIRST FLOOR WITHIN A MIN. OF 10%OF THE LEAST WALL&PARTITION HORIZONTAL DIMENSION NEW EXTERIOR DEMOLITION AND COLLAR TIES TO LOCATED IN THE WALL UPPER 113 RD OF THE ATTICCONSTRUCTION BATH WINDOW TO CONFORM "EW W1ND0W PLANS TO THE HAZARDOUS GLAZING OA REQUIREMENTS AS PER SECTION 308.4 � NEW DOOR Drawn By Checked By OF THE NEW YORK STATE: RES. CODE. 1� J.E.M. J.E.M. TEMPERED GLASS REQUIRED AT GLASS OPENINGS WITHIN 18"AFF O HARDWIRE SMOKE O SD DETECTOR Drawing No. BLOCK UNDERSIDE OF NON-BEARING INTERIOR WALLS RUNNING PARALLEL 7, CO CARBON MONOXIDE A-2 W/FLOOR JOIST. DETECTOR r Sheet 3 of 5 t i TABLE: 3. 1 (NAIILING SCHEDULE) JOINT DESCRIPTION # OF NAILS NAIL SPACING LC " 110 VN ROOF FRAMING N GROUND SNOW LOAD-20 PSF Rafter to Top Plate (Toe-nailed) (see Table 3.3A) per rafter AS PER FIGURE 301.2(5)GROUND SNOW LOAD FOR NYS W.H. H.U. Ceiling Joist to Top Plate (Toe-nailed) (see Table 3.3A) per joist WIND SPEED-130 MPH Ceiling Joist to Parallel Rafter(Face-nailed) (see Table 3.7) each lap AS PER FIGURE 301.2(6)BASIC WIND SPEEDS FOR 50 YEAR Ceiling Joist Laps over Partitions (Face-nailed) (see Table 3.7) each lap MEAN RECURRENCE INTERVAL Collar Tie to Rafter(Face-nailed) (see Table 3.4) per tie AS PER FIGURE R301.2.11 DESIGN CRITERIA-WHERE WIND _ Blocking to Rafter(Toe-nailed) 2- 8d each end SPEED IS 130 MPH OR ABOVE SHALL BE DESIGNED IN .@16" F.J. - w I ,�'"' "°� 2x4 BEARING UP @16" O.C. N � I '° '�� �. �''�"C �� �. �:� Rim Board to Rafter(End-nailed) 2- 16d each end ACCORDANCE WITH THE AF&PA WOODFRAME CONSTRUCTION WALL MANUAL FOR ONE AND TWO FAMILY DWELLINGS-WFCM "? 321 RIVERSIDE DR WALL FRAMING SEISMIC DESIGN CATEGORY-C M `V RIVERHEAD, NY 11901 Top plate p ( )to To Plate Face-nailed 2- 16d per foot AS PER FIGURE R301.2(2)INTERNATIONAL RES.CODE SEISMIC Cn I Top Plate at Intersections (Face-nailed) 4- 16d joints-each side DESIGN CATAGORY Stud to Stud (Face-nailed) 2- 16d 24"o.c. SUBJECT TO DAMAGE FROM WEATHERING SEVERE I (516)376-8594 Header to Header(Face-nailed) 16d 16" o.c. along edges AS PER FIGURE R301.2(3)WEATHERING PROBABILITY MAP FOR Top or Bottom Plate to Stud (E:nd-nailed) 2- 16d per 2 x 4 stud CONC. UP 3- 16d per 2 x 6 stud FROST LINE DEPTH-3' 13'-2 1/2" 11 11'-8 1/2" 11'-8" 4- 16d per 2 x 8 stud AS PER R403.1(1)CONCRETE AND MASONRY DETAILS Bottom Plate to Floor Joist, Band Joist, 2- 16d per foot TERMITE-MODERATE TO HEAVY End Joist or blocking (Face-nailed) AS PER R301.2(6)TERMITE INFESTATION MAP `— — — — FLOOR FRAMING DECAY-SLIGHT TO MODERATE I MICROLAM LVL BEAM AS PER R301.2(7)DECAY PROBABILITY MAP Joist to Sill, Top Plate or Girder(Toe-nailed) 4-8d per joist WINTER DESIGN TEMP.-SUFFOLK CTY II-NASSAU COUNTY 13 LU w Bridging to Joist(Toe-nailed) 2-8d each end AS PER N1101.2 CLIMATIC CONDITIONS FOR NYS Blocking to Joist(Toe-nailed) 2-8d each end ICE SHIELD AND UNDERLAYMENT REQUIRED-YES Blocking to Sill or Top Plate (Toe-nailed) 3- 16d each block - AS PER N SEC 905.7.1-IN AREAS ERE THE AVERAGE TEMP.IN X N WH Ledger Strip to Beam (Face-nailed) 3- 16d each joist cv Joist on Ledger to Beam (Toe-nailed) 3-8d per joist JANUARY IS 25 DEGREES F(-4 DEGREES C)OR LESS OR WHEN TABLE v I coBand Joist to Joist(End-nailed) 3- 16d per joist R301.2(1)CRITERIA SO DESIGNATES.AS ICE BARRIER THAT CONSISTS Band Joist to Sill or Top Plate (Toe-nailed) 2- 16d per foot OF UNDERLAYMENT CEMENTED TOGETHER OR A SELF ADHERING POLYMER MODIFIED BITUMEN SHEET SHALL BE USED IN LIEU OF NORMAL UNDERLAYMENT AND EXTEND FROM THE EAVES EDGE _2"X10" F.J. 2"A T F.J. ROOF SHEATHING POINT AT LEAST 24"INSIDE THE EXTERIOR WALL LINE OF BUILDING. @16" O.C. @16"O.C. I Structural Panels 8d 12" o.c. I Diagonal Board Sheathing *CODE COMPLIANCE NOTE* 1"x6"or 1"x8" 2-8d per support THIS PROJECT COMPLIES WITH THE 2020 RESIDENTIAL CODE OF N.Y.S. 1"x10 or wider 3-8d per support THE MECHANICAL CODE OF N.Y.S., CHAPTERS 12 THROUGH 24, THE PLUMBING CODE OF NY STATE, CHAPTERS 25 THROUGH 32,AND THE CEILING SHEATHING ELECTRICAL CODE OF NY STATE,CHAPTERS 33 THROUGH 42. OIL I Gypsum Wallboard 5d coolers 7"edge/10"field TANK Q Client Info ANDREW OPPENHEIMER& NICOLE WALL SHEATHING A.COMMON OR BOX NAILS ARE PERMITTED TO BE USED EXCEPT WHERE OTHERWISE DOBRANSKI STATED. Structural Panels 8d 12"o.c. B.NAILS SPACED AT 6"OC AT EDGES,12 AT INTERMEDIATE SUPPORTS EXCEPT 6"AT 1400 Track Ave Fiberboard Panels SUPPORTS WHERE SPANS ARE 48"OR MORE.FOR NAILING OF WOOD STRUCTURAL Cutchogue, NY 11935 7/16" 6d 3"edge/6"field PANEL&PARTICLE BOARD DIAGRAMS AND SHEAR WALLS,REFER TO SECTION 2305. WELL EQUIP. I 25/32" 8d 3" edge/6"field NAILS FOR WALL SHEATHING ARE PERMITTED TO BE COMMON,BOX OR CASING. I Gypsum Wallboard 5d coolers 7"edge/10"field C.COMMON OR DEFORMED SHANK. Project Info D.coMMON. Hardboard 8d 12" o.c. E.DEFORMED SHANK. BASEMENT FLOOR PLAN 0 LEGALIZE EXISTING BATHROOM Particleboard Panels 8d 12" o.c. Diagnonal Board Sheathing F.CORROSION RESISTANT SIDING OR CASING NAILS. SCALE: 1/4" = 1'-0" AND LAUNDRY ROOM 1"x6"or 1"x8" 2-8d per support G.FASTENERS SPACED 3"OC AT EXTERIOR EDGES&6"OC AT INTERMEDIATE SUPPORT. 1400 Track Ave 1"x10"or wider 3-8d per support H.CORROSION RESISTANT ROOFING NAILS WITH 7/16"DIA HEAD AND 1 1/2"LENGTH FOR 1/2"SHEATHING AND 1 3/4"LENGTH FOR 25132"SHEATHING. Cutchogue, NY 11935 I.CORROSION RESISTANT STAPLES WITH NOMINAL 7116"CROWN AND 1 1/8"LENGTH FOR FLOOR SHEATHING 1/2"SHEATHING AND 1 1/2"LENGTH FOR 25132"SHEATHING.PANEL SUPPORTS AT 16"(20" Structural Panels OF STRENGTH AXIS IN THE LONG DIRECTION OF THE PANEL UNLESS OTHERWISE MARKED) 1"or less 8d 6" edge/12"field J.CASING OR FINISH NAILS SPACED 6"ON PANEL EDGES,12"AT INTERMEDIATE SUPPORT. > K.PANEL SUPPORTS AT 24".CASING OR FINISH NAILS SPACED 6"ON PANEL EDGES, L_ greater than 1" 10d 6" edge/6"field INTERMEDIATE SUPPORTS. 01- a Diagnonal Board Sheathing I.FOR ROOF SHEATHING APPLICATIONS,8D NAILS ARE THE MIN.REQ'D FOR WOOD Q 1"x6" or 1"x8" 2-8d per support ° ° ° 1"x10"or wider 3- 8d per support STRUCTURAL PANELS. ° ° M.STAPLES SHALL HAVE MIN.CROWN WIDTH OF 7/16". ° is N.FOR ROOF SHEATHING APPLICATIONS,FASTENERS SPACED 4"OC AT EDGES,8"AT ° INTERMEDIATE SUPPORTS. ° MINIMUM UNIFORM D I S TR I I B U TE D DESIGN LOADS 0.FASTENERS SPACED 4"O.C.AT EDGES,8"O.C.AT INTERMEDIATE SUPPORTS FOR SUBFLOOR&WALL SHEATHING AND 3"OC AT EDGES,6"AT INTERMEDIATE SUPPORTS ( REFER TO TABLE R301.5 OF THE RESIDENTIAL CODE OF NEW YORK STATE ) FOR ROOF SHEATHING. V) O USE LIVE LOAD DEAD LOAD P.FASTENERS SPACED 4"OC AT EDGES,8"AT INTERMEDIATE. Z i'' O o- � 'C EXTERIOR BALCONIES 60 PSF 10 PSF RIDGE is CD DECKS 40 PSF 10 PSF R905.25 FASTENERS STRUCTURAL RIDGE SIMPSON STRONG TIE WITH 0 FASTENERS FOR ASPHALT SHINGLES SHALL BE GALVANIZED STEEL,STAINLESS STEEL, SIMPSON STRONG TIE CEIL.COLLAR TIES @32"O.C. SHINGLE—-, RIDGE VENT PASSENGER VEHICLE GARAGES 50 A PSF AS PER PLAN ALUMINUM OR COPPER ROOFING NAILS,MIN.12 GAGE SHANK W/A MIN.3/8"HEAD ASTMF CATHEDRAL CEILINGS CS-20X18"MIN.WITH(7)1 OD RIDGE CAP EXHAUST AIR ATTICS WITHOUT STORAGE:- (ROOF BELOW 3 PITCH) 10 PSF 10 PSF 1667,OF A LENGTH TO PENETRATE THROUGH THE ROOFING MATERIALS& A MIN.OF 3/4" (R-R) COMMON NAILS PER RAFTER ATTICS WITH STORAGE (ROOF BELOW 3 PITCH) 20 PSF 10 PSF INTO THE ROOF SHEATHING.WHERE THE ROOF SHEATHING IS LESS THAN 3/4"THICK. INSTALLED OVER PLYWOOD SHINGLES PLYWOOD ROOMS OTHER THAN SLEEPING ROOMS 40 PSF 10 PSF THE FASTENERS SHALL PENETRATE THROUGH THE SHEATHING R905.26 ASPHALT ROOF FELT SHEATHING SHINGLS SHALL HAVEA MIN.OF SIX FASTENERS PER SHINGLE WHERE THE ROOF IS IN PAPER SLEEPING ROOMS 30 PSF 10 PSF ONE OF FOLLOWING CATEGORIES-THE BASIC WIND SPEED PER R301.2(4)IS 110 MPH OR a? STAIRS 40 PSF 10 PSF GREATER&THE EAVE IS 20'ABOVE GRADE R905.27 FOR ROOF SLOPES FROM 2 VERTICAL F2 v UNITS IN 12 UNITS HORIZONTAL UP TO 4 UNITS VERTICAL IN 12 UNITS HORIZONTAL UNITS AFTER F. r GUARDRAILS AND HANDRAILS 200 PSF 10 PSF SHALL BE TWO LAYERS. ROOF LOADING LIVE-GROUND SNOW LOAD 30 PSF 10 PSF % j F OW / o D O TABLE R402.2 j CAL RIDGE VENT DE TABLE IR301 .5 MINIMUM SPECIFIED COMPRESSIVE % UJ • �Q MIN. ROOF LIVE LOADS IN STENGTH OF CONCRETE TRUSS AND RAFTER , o,NARD POUNDS-FORCE PER S.F. OF WOOD TOP PLATOE MINIMUM SPECIFIED HIP RAFTER GALV.MTL.TIES @EACH HORIZONTAL (PROJECTION COMPRESSIVE STRENGTHa(fc ) FACE MOUNT HANGER TYPE OR LOCATION OF SIMPSONSTRONGTIE SIMPSON STRONG TIE(LUS) STUD(TYP.OF ALL) TRIBUTARY LOADED AREA IN S.F. CONCRETE CONSTRUCTION WEATHERING POTENTIAL LUS26,LUS28,LUS26-2 #LS70 : 1tpt FOR ANY STRUCTURAL MEMBER NEGLIGIBLE MODERATE SEVERE Lus 28-2,LUS210-2 I `+ J - j o87 �� � FLOOR JOISTS Ofi ROOF SLOPE: 0 TO 200 201 TO 600 OVER 600 BASEMENT WALLS, FOUNDATIONS AND OTHER 2,500 2,500 2,500 CONCRETE NOT EXPOSED TO THE WEATHER FLAT OR RISE LESS BASEMENT SLABS AND INTERIOR SLABS ON BP 20 16 12 2,500 2,500 2,500 THAN 4 IN. PER FT. (1:3) GRADE, EXCEPT GARAGE FLOOR SLABS. SP4 l° FOUNDATION RISE 4 IN. PER FT. (1:3) TO BASEMENT WALLS, FOUNDATION WALLS, EXTERIOR HD38 SP1 LESS THAN 12 IN. PER FT. (1:1) 16 14 12 WALLS & OTHER VERTICAL CONC. WORK EXPOSED 2,500 3,000d 3,000d MTS12 HCP2 H2 5 PLAN AND TO THE WEATHER. e RISE 12PER FT. (2)H4 DETAILS (1:1)ANDND 2500 3000 3000 GREATER 12 12 12 PORCHES, CARPORT SLABS AND STEPS EXPOSED d e d e TO THE WEATHER, AND GARAGE FLOOR SLABS. , , , TOP PLATES R905.2.5- FASTENERS MAS FASTENERS FOR ASPHALT SHINGLES SHIALL BE GALVANIZED STEEL, STAINLESS H8 Drawn By Checked By STEEL, ALUMINUM OR COPPER ROOFING NAILS MIN 12 GAGE SHANK WITH A MIN TABLE R 301.2(1) MAS • 3/8" HEAD ASTMF1667 OF A LENGTH TO PENETRATE THROUGH THE ROOFING AND A MIN OF MATERIALS 3/4" INTO THE [ROOF SHEATHING WHERE THE ROOF CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA CONTIPNUOUS CORNER J.E.M. J.E.M. SILL PLATE TO SHEATHING IS LESS THAN 3/4"THINK THE FASTENERS SHALL PENETRATE SUBJECT TO DAMAGE FROM 12 HIP CORNER PLATE POST STRAPPING POST BASE GALV.MTL.TIES FOUNDATION GROUND WIND SEIMIC WINTER ICE SHIELD FLOOD BLOCKIN Drawing No. THROUGH THE SHEATHING R905.2.6-AS[PHALT ROOF SHINGLES SHALL HAVE A SNOW SPEED DESIGN WEATHERING . FROST TERMITE DECAY DESIGN UNDERLAYMENT HAZARDS SIMPSON STRONG TIE(HCP) SIMPSON'STRONG TIE SIMPSON STRONG TIE Gay g MINIMUM OF SIX FASTENERS 3/8" PER SHINGLE WHERE THE ROOF SLOPE IS IN LOAD (MFH) CATEGORY LINE DEPTH TEMP REQUIRED HCP2-2"XMEMBERSIZE VERTICALIHD38 #ABA4q ETAL STR DETAIL ONE OF THE FOLLOWING CATEGORIES: TFHE BASIC WIND SPEED IS 110 MPH OR HCP4-4"X MEMBER SIZE A-3 GREATER AND THE EAVE IS MORE THAN 20'ABOVE GRADE. 20 PSF 130 C SEVER 3' M-H S-M 11° YES Sheet 4 of 5 NOTESGENERAL R-15 3"RIGID INSULATION.SEAL FOUNDATIONS AND SLABS SHALL BE COMPACTED TO TIE INTERSECTING WALLS WITH TRUSS TYPE SHALL BE FOIL FACED(TYPICAL) DIVISION 1 ALL SEAMS AROUND RIGID E GENERAL NOTES: A MINIMUM OF 96%MAXIMUM DENSITY IN REINFORCING 16 O.C.VE RTTCALLY TO EXTEND 2' MUD SILL SHALL BE OF WOLMANIZED LUMBER 2X8 INSULATION WITH SPRAY FOAM t ACCORDANCE WITH THE MODIFIED PROCTOR TEST. ABOVE FOR ALL MASONRY CONSTRUCTION BELOW PLATE,SECURE TO FOUNDATION WALL WITH'/z" INSULATION: I THE CONTRACTOR SHALL VISIT THE SITE AND VERIFY MAINTAIN 1:5:1 HORIZONTAL TO VERTICAL SLOPE GRADE. DIAMETER ANCHOR BOLTS,MAX.6-0"O.C.,AND MAX. 1. 2 X 6 WALLS=R-19 2 FEET FROM CORNERS. 2. CEILING&ROOF=R-49 ALL CONDITIONS. ANY DISCREPANCIES,VOIDS OR FOR ANY EXCAVATION ADJACENT TO FOOTINGS. 3. FLOORS OVER UNHEATED SPACES=R-30 CONTINUOUS CAULK OR SPRAY FOAM PROBLEMS SHALL BE REPORTED TO THE ARCHITEECT REINFORCING: SUBMISSION OF BID WHERE WALLS ARE POURED TO GRADE,THE.A PROVIDE LINTELS OR HEADERS AT ALL OPENINGS, SEALANT AT ALL TOP PLATES AND SILL BEFORE SUBMISSION OF BID. INSULATE R SHALL IMPLY CONT RACTOR ACCEPTANCE OF THE CONTRACTOR SHALL BACKFILL AGAINST THEM WITH TRUSS TYPE,CONTINUOUSLY WELDED WIRE AS WHETHER OR NOT INDICATED ON THE PLANS. NOTE:I NSULATE ALL ATTIC SPACES AND ALL PLATES 7 DRAWINGS AND ALL EXISTING CONDITIONS. CLEAN EARTH. CARE SHALL BE TAKEN TO BRACE MANUFACTURED BY DURO-WALL OR EQUAL,9GA; HEADERS AT NON-BEARING CONDITIONS SHALL BE AS EXTERIfOR WALLS. SILL SEAL INSULATION BETWEEN SILL THE WORK ADEQUATELY TO PREVENT DEFORMATION FOLLOW MANUFACTURER'S INSTALLATION DETAILS. FOLLOWS: PLATES DURING THE COURSE OF CONSTRUCTION IF OR COLLAPSE. IF 4'-0"OR LESS...................................3-1/2"X 9-1/2" FLASHING: MODIFICATIONS TO THE DESIGN OCCUR AS A RESULT PROVIDE MISC.ANCHORS AND TIES AS REQUIRED. LVL OF EXISTING CONDITIONS,REQUEST OF CLIENT, ALL MATERIALS USED FOR BACKFILL SHALL BE FREE MINIMUM 14GA GALVANIZED STEEL OR 3/8" IF 6-0"OR LESS...................................3-1/2"X 11-7/8" FLASHING WORK SHALL INCLUDE ALL FLASHING CONTINUOUS CAULK OR SPRAY 17 OR REQUIRED FOR A COMPLETE INSTALLATION OF NEW FOAM IN ALL SEAMS OF SUBFLOOR oo Z _ ' 11 11 DIAMETER GALV.STEEL ROD. "" ARCHITECT,ETC.THE CONTRACTOR SHALL SUBDVIIT OF DEBRIS AND ORGANIC MATERIAL LARGER THAN 2 5-1/4"X 9-1/2"LVL ROOFING,TRIM,ENTRANCES,ALL INDICATED ON TO CREATE AN AIR SEAL FROM � � -" " ' TWO WRITTEN COPIES OF A CHANGE ORDER WITH INCHES IN DIAMETER,LENGTH OR WIDTH. MORTAR: 1F 8'-0"OR LESS...................................5-1/4"X 11-7/8" DRAWINGS. REPAIR AND/OR REPLACEMENT OF FIRST FLOOR TO BASEMENT THE AMENDED PRICE. THE CONTRACTOR SHALL,NOT CONTINUE WITH ANY CHANGES UNTIL HE RECEIVES WATER SHALL NOT BE ALLOWED TO STAND IN LVL GUTTERS AND DOWNSPOUTS AS REQUIRED TO AUTHORIZATION FROM OWNER OR EXCAVATIONS UNTIL AFTER CONCRETE WORK HAS USE TYPE"M"MORTAR CONFORMING TO ASTM C-270 IF A HEADER IS NOT INDICATED AT A BEARING CREATE A WATER TIGHT JOB. \ 321 RIVERSIDE D R WRITTEN (2)2X6 ACO SILL PLATE WITH SET. CONTRACTOR SHALL REMOVE SUCH WATER AT CONDITION,INFORM THE ARCHITECT BEFORE CONTINUOUS BITUMEN LAMINATED R I V E R H EA D, NY 11901 ARCHITECT. HIS WON EXPENSE. ALL MORTAR SHALL BE MIXED A MINIMUM OF 5 PROCEEDING. FLASHING FOR ROOFING SHALL BE COPPER SHEET: COPPER TERMITE SHIELD AND SILL a IF IN THE COURSE OF CONSTRUCTION,A CONDITION MINUTES IN A MECHANICAL BATCH MIXER. DO NOT ASTM, 160Z.(0.0216")(COLD ROLLED). SEPARATE ALL SEAL INSULATION ,�� EXISTS WHICH DIFFERS FROM THAT AS INDICATIED ON TEMPORARY SHEET PILING,SHORING OR BRACING RE-TEMPER AFTER 2 HOURS HAS ELAPSED. DO NOT ALL WALLS(EXTERIOR)SHALL BE BRACED AGAINST DISSIMILAR METALS WITH BITUMINOUS COATING. 516 376-8594 THESE PLANS,THE CONTRACTOR SHALL STOP ALL SHALL BE PROVIDED AS REQUIRED TO MAINTAIN USE MORTAR,WHICH HAS ELAPSED. DO NOT USE LATERAL LOADS BY STRUCTURAL SHEATHING, 16 GA. JOINTS,TO BE SOLDERED. RELATED WORK AND NOTIFY THE ARCHITECT. EXCAVATION BANKS IN A SAFE AND STABLE MORTAR,WHICH HAS BEGUN TO SET. STEEL STRAPPING,OR LET IN 1 X4 CORNER BRACING. SHOULD HE FAIL TO FOLLOW THESE PROCEDURES CONDITION. DIVISION 8 MAINTAIN A CONSTANT JOINT WIDTH THROUGHOUT MTCROLAM: DOORS AND WINDOWS: AIR SEALING AT SILL PLATE AND CONTINUE WITH THE WORK,HE SHALL ASSUME ALL RESPONSIBILITY AND LIABILITY ARISING THTERE NO BLASTING SHALL BE PERMITTED. THE WORK. UNLESS OTHERWISE INDICATED OR ALL 3/4"=1'-0" FROM. NOTED. JOINTS SHALL BE A MINIMUM' "WIDE. SCOPE: WINDOWS: (SEE WINDOW SCHEDULE.) /4 CONTRACTOR SHALL RETAIN A LICENSED CIVIL THIS WORK INCLUDES THE COMPLETE FURNISHINGS THE AIA DOCUMENT A-201 (LATEST EDITION) ENGINEER TO PERFORM ALL DESIGN AND MORTAR MATERIALS SHALL BE AS FOLLOWS: AND INSTALLATION OF ALL"MICRO-LAM"LUMBER WINDOWS BY LOW-E GLASS. SIZE AND FUNCTION AS "GENERAL CONSTRUCTIONS,OR THE CONTRACT'FOR SUPERVISION RELATED TO EXCAVATION, -PORTLAND CEMENT:CONFORM TO ASTM C-150,TYPE BEAMS AS SHOWN IN THE DRAWINGS,HEREIN INDICATED-CONTRACTOR TO VERIFY SIZES,(ROUGH CONSTRUCTION"SHALL PREVAIL WHENEVER UNDERGROUND UTILITY SERVICES, I. SPECIFIED AND NECESSARY TO COMPLETE THE WORK. OPENINGS)WITH MODEL NUMBERS PRIOR TO POSSIBLE. (SUBSTANDARD-LESS THAN 2-TON/SQ.FT.)SOILS -QUICKLIME:CONFORM TO ASTM C-5,PLANT MIXED ORDERING WINDOWS,AND TO REPORT ANY ENCOUNTERED,ROADS,AND SITE STRUCTURES NOT ONLY AND THOROUGHLY SLAKED PRIOR TO USE. MATERIALS: DISCRIEPANCIES TO ARCHITECT. ALL WORK SHALL CONFORM TO THE 2010 NEW WORK USUALLY CONSIDERED ARCHITECTURAL IN NATURE. MAX MAGNESIUM OXIDE=8% THE MICRO-LAM LUMBER BEAMS SHALL BE CONTINUOUS CAULK OR SPRAY FOAM IN ALL STATE RESIDENTIAL BUILDING CONSTRUCTION i CODE -HYDRATED LIME:CONFORM TO ASTM C-207,TYPE S. MANUFACTURED FROM MICRO-LAM BRAND PROVIIDE AND INSTALL ALL INSECT SCREENS AND _ _ SEAMS OF SUBFLOOR TO CREATE AN AIR (LATEST EDITION)AND ALL RULES AND ALL BASEMENT WALLS BELOW GRAD SHALL BE -AGGREGATE:CONFORM TO ASTM C-144,OR C-404, PARALLEL LAMINATED VENEER LUMBER UTILIZING HARDWARE AS REQUIRED. SEAL FROM FIRST FLOOR TO BASEMENT REGULATIONS THEREIN AND WITH ALL OTHER DAMP-PROOFED WITH TWO COATS OF ASPHALTIC, SIZE#2. AGGREGATE SHALL NOT EXCEED FOUR 1/10"OR 1/8"THICKNESS DOUGLAS FIR VENEER GLUED AGENCIES HAVING JURISDICTION. SELF-PRIMING PLASTIC CEMENT,TROWEL OR SPRAY TIMES THE PORTLAND CEMENT. UP IN A CONTINUOUS PIECES WITH ALL GRAIN ALL GTLASS WITHIN 18"OF FLOOR TO BE TEMPERED. APPLIED TO WALLS IF WATER TABLE IS DETERMINED -WATER:POTABLE PARALLEL WITH THE LENGTH OF THE MEMBER. IGHT TO UN THE CONTRACTOR SHALL MAKE SURE THAT ALIL TO BE MINIMUM 2 FEET BELOW BASEMENT SLAB -MOISTURE RESISTANT ADDITIVE: AMMONIUM LAMINATED VENEER LIMBER SHALL BE OF SINGLE DOORS: (SIZE AS INDICATED ON PLANS) TIGHT TO UNDDERSIDE OF FLOOR BAST INSULATION INSTALLED TRADE'S WORK CONFORMS TO FEDERAL,STATE;AND ELEVATION. BENTONITE OR 60 ML LIQUID STEZRATE,ALUMINUM TRISTERATE,OR CALCIUM ONE-PIECE LENGTH,FREE OF RINGER JOINTS,SCARF T MUNICIPAL CODES(BOCA)AND ORDINANCES. 'TI'HESE WATERPROOF MEMBRANE AS MFR. BY ANTI-HYDRO STEARATE. JOINTS OR MECHANICAL CONNECTIONS IN FULL SKYLI(GHTS:(AS INDICATED ON PLANS.UNLESS SHALL SUPERSEDE DRAWINGS,NOTES AND OR EQUAL SHALL BE USED IF WATER TABLE IS LENGTH. OTHERWISE NOTED SKYLIGHTS TO BE BY DIMENSIONS INS ALL CASES. THE ARCHITECT SHHALL HIGHER. CONTRACTOR SHALL VERIFY WATER TABLE DIVISION 5 "ANDEIRSEN"-LOW-E GLASS.) AIR SEALING AT BASEMENT TO FIRST FLOOR BE NOTIFIED OF SUCH CHANGES BEFORE WORK.IS IN THE FIELD. MISC. METALS: MEMBERS: SCALE: 3/4"=1'-0" STARTED. NON-FAMILIARITY WITH GOVERNING3 VENEERS SHALL BE DRIED AS REQUIRED.ADHESIVE DMSI(ON 9 RULES AND REGULATIONS WILL NOT BE CAUSE',FOR DIVISION 2 STEEL WORK,IN GENERAL,SHALL CONFORM TO THE USED TO LAMINATE THE VENEER SHALL BE FINISIH SCHEDULE: AN"EXTRA"BILLING. IN THE,EVENT THAT WORK HAS SITE WORK: FOLLOWING AMERICAN INSTITUTE OF STEEL WATERPROOF,MEETING THE REQUIREMENTS OF TO BE REPLACED FOR NON-COMPLIANCE,THE CONSTRUCTION STANDARDS. ASTM D-2559-76,UNIFORMLY APPLIED TO THE VENEER INTERIIOR WALLS AND CEILING: TAPE AND SPACKLE CONTRACTOR SHALL BE HELD RESPONSIBLE IF]HE LANDSCAPING:ALL TREES AND SHRUBS WHICH AT THE REQUIRED SPREAD RATE. DRYWALL,3 COATS(1 PRIME,2 FINISH). TAPE SHALL HAS NOT NOTIFIED THE ARCHITECT BEFORE INITIAL INTERFERE WITH THE CONSTRUCTION OF THIS -CODE OF STANDARD PRACTICE FOR BUILDERS AND BE FIBIERGLASS TYPE. WALLS AND CEILING TO BE INSTALLATION. PROJECT SHALL BE REMOVED;AND NEW BRIDGES DESIGN: READW FOR PAINT. ALL DRYWALL SHALL BE ORNAMENTAL TREES AND SHRUBS PLANTED,NEW -SPECIFICATIONS FOR THE DESIGN,FABRICATION, MICRO-AM LUMBER BEAMS SHALL BE DESIGNED TO ATTACHED TO FRAMING WITH SCREWS,MAX. 12"O.C. Client Info THE CONTRACTOR SHALL MAKE ANY CORRECTTIONS LAWN AREAS SHALL BE SEEDED AFTER FINISHED AND ERECTION OF STRUCTURAL STEEL BUILDINGS, MEET THE DIMENSIONS AND LOADS INDICATED ONOF ALL REQUIRED BY THE ARCHITECT.APPROVAL OF GRADING IS COMPLETE. INCLUDING THE COMMENTARY AND SUPPLEMENTS. THE PLANS. ALL DESIGNS SHALL BE IN ACCORDANCE INTERIIOR TRIM:ALL TRIM JOINTS TO BE FILLED WITH AIR SEAL THE INTERSECTIONS SECTIO S FULLY ANDREW OPPENHEIMER & NICOLE -SPECS FOR STRUCTURAL JOINTS USING ASTM A-325 WITH STANDARD ENGINEERING PRACTICE. WOOD)FILLER AND SANDED READY FOR PAINT. wALLsIArnC INTERSECTIONS FULLY DRAWINGS OR SCHEDULES SHALL NOT RELIEVE THE WITH SPRAY FOAM.SEAL ALL BAIT INSULATION BETWEEN CEILING JOISTS DOBRANSKI CONTRACTOR WILL VERIFY OR A-490 BOLTS. COMPLETE DESIGN CALCULATION SHOWING MEMBER ELECTRICAL,PLUMBING,ETC. SEE SECTIONS 1400 Track Ave CONTRACTOR FROM RESPONSIBILITY FOR STORM DRAINAGE: FORCES AND STRESSES AND ALLOWABLE LOAD ARE DNISI(ON 10 PENETRATIONS INTO ATTIC DEVIATIONS FROM DRAWINGS AND SPECIFICAT REQUIREMENTS IONS, LOCAL AUTHORITIES FRO STORM COMPLY WITH THE FOLLOWING AMERICAN WELDING TO BE AVAILABLE UPON REQUEST FOR EACH SPECLALTIES: IF USED,SPECIFIED ON PLANS. CUtchogue, NY 11935 UNLESS HE HAS CALLED ATTENTION TO SUCH DRAINAGE. DEVIATIONS(IN WRITING)AT THE TIME OF SOCIETY STANDARDS: MICRO-LAM LUMBER DESIGN. THE DESIGN OF THE SUBMISSION OF BID AND SECURED WRITTEN SOILS: AWS DI A STRUCTURAL WELDING CODE MICRO-LAM LUMBER BEAMS IS TO BE UNDER THE DNISI(ON 11 HIM FROM AWS D12.1 REINFORCING STEEL WELDING CODE SUPERVISION OF A REGISTERED PROFESSIONAL EQUIPMENT: TOP PLATE APPROVAL. NOR SHALL IT RELIEVE RESPONSIBILITY FOR ERRORS SHOP DRAWINIGS OR EXCAVATE FOR ALL FOOTINGS,FOUNDATION WALLS, ENGINEER AND IN ACCORDANCE WITH THE NRB Project Info COMPLY WITH ASTM A-6,GENERAL REQUIREMENTS ACCEPTANCE,AND PROVISIONS OF THE NATIONAL APPLIANCES SUPPLIED BY OWNER AND INSTALLED 1/z^GYPSUM WALLBOARD LEGALIZE EXISTING BATHROOM SCHEDULES OR THE PROPER PERFORMANCE OF' AND OTHER SUCH WORK AS MAY BE NECESSARY TO FOR DELIVERY OF ROLLED STEEL PLATES,SHAPES, DESIGN SPECIFICATION FOR WOOD 1984.E BY CONTRACTOR. CONFIRM REQUIRED TRENCHES FOR FOOTINGS,FOUNDATIONS,SLABS, SHEET PILING,AND BARS FOR STRUCTURAL USE. MECHIANICAL/ELECTRTCAL HOOK-UPS. 2X4 WOOD STUD AND LAUNDRY ROOM MECHANICAL EQUIPMENT AND CONTROLS. THE DEPTHS AS SHOWN ON THE DRAWINGS.ALL THE WORD"PROVIDE"SHALL MEAN TO FURNISIH AND ETC.SHALL HAVE LEVEL,SOLID AND UNDISTURBED PROTECTION: 1400 Track Av e INSTALL ALL MATERIALS NECESSARY TO COMTPLETE BOTTOMS. CONFORM TO VARIOUS ASTM STANDARDS,AS NOTED, THE MICRO-LAM LUMBER BEAMS,LIKE ANY OTHER DNISIION 12 Cutchogue, NYY 11935 THE WORK IN ACCORDANCE WITH ACCEPTED AND ALL REQUIREMENTS OF THE GOVERNING WOOD PRODUCT,SHALL BE EL FURNIISHINGS:NOT USED CONSTRUCTION STANDARDS AND MANUFACTURER'S ALL SOIL BEARING CAPACITY ASSUMED AT 2 TONS/ AUTHORITIES. RECOMMENDATIONS. SQUARE FOOT,CONTRACTOR SHALL VERIFY IN FIELD. PROTECTION: DNISIION 13 MATERIALS PROPERTIES: THE MICRO-LAM LUMBER BEAMS,LIKE ANY OTHER SPECIIAL CONSTRUCTION:NOT USED AIR SEALING AT INTERIOR WALLS/ATTIC -ID (D ALL ITEMS SPECIFIED ARE TO ESTABLISH QUALITY OF FILL USED OR ENCOUNTERED UNDERNEATH WOOD PRODUCT,SHALL BE EXERCISED DURING SCALE: 3/4"=1'-0" WORK;PRODUCTS OF OTHER MANUFACTURER'S FOUNDATIONS AND SLABS SHALL BE COMPACTED TO 1. STRUCTURAL STEEL SHAPES,PLATES,AND BARS HANDLING TO PREVENT DAMAGE TO THE BEAMS. DIVISIION 14 EQUAL IN DESIGN,COLOR AND QUALITY MAY BE A MINIMUM OF 96%MAXIMUM DENSITY IN SHALL BE ASTM A-36. CONV'EYING SYSTEMS:NOT USED CL C- SUBSTITUTED IF APPROVED BY THE ARCHITECT]'AS ACCORDANCE WITH THE MODIFIED PROCTOR TEST. 2. COLD FORMED STEEL TUBING SHALL CONFORM HARDWARE: Q MEETING ESTABLISHED DESIGN AND FUNCTIONAL MAINTAIN 1:5:1 HORIZONTAL TO VERTICAL SLOPE TO ASTM A-501 ALL HARDWARE IS TO BE FABRICATED BY OTHERS DIVISRON 15 CRITERIA. FOR ANY EXCAVATION ADJACENT TO FOOTINGS. 3. STEEL PIPE:ASTM A-53,TYPE E OR S,GRADE B. ACCORDING TO DETAILS CONTAINED IN THE MECHAANICAL:PROVIDED BY HVAC BLACK FINISH,EXCEPT WHERE INDICATED TO BE CONTRACT DRAWINGS. ENGIMEER/ENGINEEER ALL WORK SHALL BE EXECUTED IN ACCORDANCE WHERE WALLS ARE POURED TO GRADE,THE GALVANIZED. 15 3"RIGID INSULATION.SEAL ALL SEAMS AROUND WITH THE BEST-ACCEPTED TRADE PRACTICES SAND AS CONTRACTOR SHALL BACKFILL AGAINST THEM WITH 4. ANCHOR BOLTS,ASTM A 307,GRADE A, INSTALLATION: ROUND RIGID INSULATION WITH SPRAY PER MANUFACTURER'S RECOMMENDATIONS. CLEAN EARTH. CARE SHALL BE TAKEN TO BRACE NON-HEADED TYPE. THE MICRO-LAM LUMBER BEAMS ARE TO BE FOAM THE WORK ADEQUATELY TO PREVENT DEFORMATION 5. ALL STEEL SHALL RECEIVE ONE OF RED OXIDE INSTALLED IN ACCORDANCE WITH THE PLANS. CONTRACTOR IS TO INDICATE TO THE ARCHITECT OR COLLAPSE. PRIMER AFTER FABRICATION IN SHOP. TEMPORARY CONSTRUCTION LOADS BEYOND LIMITS V) o THE PROPOSED DATES AND]HOURS DURING WT�ITCH INDICATED THEREON ARE NOT PERMITTED. HOLES, % Z WORK SHALL BE PERFORMED. THE CONTRACTOR ALL MATERIALS USED FOR BACKFILL SHALL BE FREE ERECTOR SHALL PROVIDE ADEQUATE TEMPORARY CUTS OR N CONTINUOUS CAULK OR SPRAY FOAM 0 NOTCHES NOT PREVIOUSLY APPROVED BY SEALANT AT ALL TOP PLATES AND SILL SHALL PREPARE AND UPDATE MONTHLY OF DEBRIS AND ORGANIC MATERIAL LARGER THAN 2 BRACING FOR LATERAL STABILITY UNTIL THE THE ENGINEER SHALL NOR BE MADE. THE FINAL STRUCTURE IS FULLY BRACED BY THE INSTALLATION ERECTION OF THE MICRO-LAM LUMBER BEAM SHALL PLATES GJ IU CONSTRUCTION SCHEDULES;COMPLETION DATE MAY INCHES IN DIAMETER,LENGTH OR WIDTH. w NOT BE EXTENDED WITHOUT WRITTEN NOTICE. OF PERMANENT STRUCTURE: BE UNDER THE DIRECTION OF QUALIFIED SILL SEAL INSULATION BETWEEN TOP WATER SHALL NOT BE ALLOWED TO STAND IN CONSTRUCTION SUPERVISOR. PLATES CONTRACTOR SHALL OBTAIN ALL REQUIRED EXCAVATIONS UNTIL AFTER CONCRETE WORK HAS DIVISION 6 BUILDING PERMITS,APPROVALS,UNDERWRITERS SET. CONTRACTOR SHALL REMOVE SUCH WATER AT WOOD: LATERAL NAIL HOLDING AND WITHDRAWAL ARE AS CERTIFICATE, "C OF O,"AND/OR COMPLETION FOR HIS WON EXPENSE. PROVIDED IN THE CODE FOR DOUGLAS FIR SAWN ALL WORK INDICATED FOR AGENCIES HAVINGI STRUCTURAL LUMBER: LUMBER. NAILS INSTALLED PARALLEL TO THE GLUE JURISDICTION. TEMPORARY SHEET PILING,SHORING OR BRACING LINES ON THE NARROW FACE SHALL NOT BE SPACED SHALL BE PROVIDED AS REQUIRED TO MAINTAIN ALL STRUCTURAL LUMBER SHALL BE CONSTRUCTION CLOSER THAN 4 INCHES FOR 10-PENNY COMMON CONTRACTOR IS TO SUPPLY OWNER,IN WRIT04G,A EXCAVATION BANKS IN A SAFE AND STABLE GRADE DOUGLAS FIR-SURFACE DRIED TOMAX. 14% NAILS AND 3 INCHES FOR 8-PENNY COMMON NAILS. N WAIVER OF ALL LIENS FOR]IIMSELF AND ALL CONDITION. MOISTURE CONTENT,STRESS GRADED LUMBER. NAILS INSTALLED PERPENDICULAR TO THE GLUE LUMBER SHALL HAVE THE FOLLOWING MINIMUM LINES ON THE WIDE FACE SHALL BE INSTALLED IN AIR SEALING AT FLOOR TO FLOOR SUPPLIERS AND SUBCONTRACTORS,AT THE TI1ME OF EACH PAYMENT REQUEST. NO BLASTING SHALL BE PERMITTED. STRESS PROPERTIES: ACCORDANCE WITH THE CODE. THESE NAILING SPECIFICATIONS ARE BASED ON A MEMBER AT LEAST SCALE: 3/4"=1'-0" DO NOT SCALE DRAWINGS, WRITTEN DIMENSIONS CONTRACTOR SHALL RETAIN A LICENSED CIVIL FB=900 PSI 3/4"THICK AND 3-1/2"WIDE. HOLDING POWER OF SUPERCEDE SCALED DIMENSIONS. ENGINEER TO PERFORM ALL DESIGN AND FV=75 PSI BOLTS INSTALLED PERPENDICULAR TO THE GLUE SUPERVISION RELATED TO EXCAVATION, E= 1,700,000 SINGLE USE LINES IS AS PROVIDED IN THE CODE FOR DENSE BOOM CLEAN AFFECTED AREAS AND CARTS AWAY UNDERGROUND UTILITY SERVICES, ALL STRUCTURAL LUMBER SHALL COMPLY WITH DOUGLAS FIR. ALL DEBRIS. (SUBSTANDARD-LESS THAN 2-TON/SQ.FT.)SOILS ENCOUNTERED,ROADS,AND SITE STRUCTURES NOT AND BE ERECTED IN ACCORDANCE WITH THE SPECIFIC APPROVAL IS REQUIRED FOR OTHER THAN CONTRACTOR SHALL FURNISH AND INSTALL ALL USUALLY CONSIDERED ARCHITECTURAL IN NATURE. NATIONAL FOREST PRODUCTS ASSOCIATION'S NAILED AND BOLTED CONNECTIONS. r ID%N ARD U MATERIAL AND EQUIPMENT AS SHOWN,AND UNLESS NATIONAL DESIGN SPECIFICATION FOR WOOD THERWISE NOTE ALL E UIPMENT SHALL BE NEW ALL BASEMENT WALLS BELOW GRAD SHALL BE CONSTRUCTION,LATEST EDITION. STRUCTURAL PROPERTIES: ROOF SHINGLES.SEE ROOF PLAN FOR ADDITIONAL INFO. O Q AND OF BEST QUALITY. DAMP-PROOFED WITH TWO COATS OF ASPHALTIC, N SELF-PRIMING PLASTIC CEMENT,TROWEL OR SPRAY ALL LUMBER SHALL BE GRADE MARKED. E=2,000,000 FB=2,800 PSI APROVIDE ICE&WATER SHIELD TO 24"INSIDE EXTERIOR WALL,OVER ALL FLASHING AND DIVISION 2 APPLIED TO WALLS IF WATER TABLE IS DETERMINED NO SUBSTITUTES ARE ACCEPTABLE,UNLESS SPACE GUTTER ATTACHMENT HARDWARE IN ACCORDANCE WITH SECTION 905.2.7.1(NYS CODE) y , 1 SITE WORK: TO BE MINIMUM 2 FEET BELOW BASEMENT SLAB PROVIDE JOIST HANGERS FOR ALL FLUSH FRAMED SPECIFICALLY NOTED BY ENGINEER. 27 ROOF RAFTERS.SEE ROOF PLAN FOR ADDITIONAL INFO. }� J�"Q�, 03974 ELEVATION. BENTONITE OR 60 ML LIQUID CONDITIONS,AS MANUFACTURED BY SIMPSON,TECO `MAINTAIN 1^AIRGAP FOR ROOF VENTING.PROVIDE VENTILATION BAFFLES AS REQUIRED �� +Iw LANDSCAPING:ALL TREES AND SHRUBS WHICH WATERPROOF MEMBRANE AS MFR. BY ANTI-HYDRO OR EQUAL. INSTALL IN ACCORDANCE WITH PLYWOOD: . . iEEV INTERFERE WITH THE CONSTRUCTION OF THIS; OR EQUAL SHALL BE USED IF WATER TABLE IS MANUFACTURER'S INSTRUCTIONS. ROOF SHEATHING SHALL BE CDX 2410 PLYWOOD,5/8" (1)LAYER OF KRAFT FACED BAIT INSULATION BETWEEN CEILING JOINTS AND(1)LAYER OF UNPAGED BAIT PROJECT SHALL BE REMOVED;AND NEW HIGHER. CONTRACTOR SHALL VERIFY WATER TABLE FOR SHEATHING SPANNING 16"OR LESS,AND 3/4" INSULATION PERPENDICULAR TO CEILING JOISTS.SEE SECTIONS FOR ADDITIONAL INFO ORNAMENTAL TREES AND SHRUBS PLANTED,INEW IN THE FIELD. ALL FLOOR JOIST SHALL BE BRIDGED AT MID-SPAN OTHERWISE. SIMPSON H2.5 HURRICANE STRAPS EVERY RAFTER UNLESS OTHERWISE NOTED SEE DETAILS LAWN AREAS SHALL BE SEEDED AFTER FINISIHED OR AT INTERVALS NOT TO EXCEED 8 FEET. METAL, RIGID INSULATION. GRADING IS COMPLETE. DIVISION 4 SOLID WOOD BLOCKING,AND(2)5/4"X 3"BRIDGING IS FLOOR SHEATHING SHALL BE 32/16"STRUCTURAL I& UNIT MASONRY: ACCEPTABLE. II C-D EXTERIOR,3/4"THICK APA RATED,T&G,GLUED GUTTER.SEE ROOF PLAN FOR ADDITIONAL INFO. GENERAL NOTES STORM DRAINAGE:CONTRACTOR WILL VERIFY AND NAILED. CONTINUOUS SPRAY FOAM SEALANT UNLESS REQUIREMENTS OF LOCAL.AUTHORITIES FRO;STORM CONCRETE BLOCK(MIN.COMPRESSIVE STRENGTH: ALL WALL OPENINGS,4 FEET WIDE OR LESS,SHALL AT THE TOP OF ALL WALLS 1X-PRE-PRIMED FASCIA BOARD WRAP W/ALUM.FASCIA CLADDING TYP.THROUGHOUT CONTINUOUS CAULK OTHERWISE NOTED & AIR SEALING HAVE DOUBLE STUDS AT JAMBS;SPANS WIDER THAN ALL PLYWOOD SHALL BE GRADE MARKED AND MEET DRAINAGE. 1800 PSI): SPRAY FOAM SEALANT 112"DRIP EDGE TYPICAL FOUR 4 FEET SHALL HAVE DOUBLE STUDS FOR THE STANDARDS OF AMERICAN PLYWOOD CONT.1"SOFFIT VENT WITH PERFORATED SOFFIT MATERIAL OF APPROVED PEST MESH DETAILS KRAFT FACEDD BAITTT TOP PLATE WITH SILL SEAL. SOILS: PROVIDE NORMAL WEIGHT (125 LBS/CU.FT.)HOLLOW HEADER BEARING PLUS JAMB STUD. ASSOCIATION.(APA) ( INSULATION.SEE SECTIONS EXTERIOR LOAD BEARING BLOCK CONFORMING TO ASTM C90, JOISTS SHALL BE DOUBLED AROUND ALL OPENINGS, FOR ADDITIONAL INFO. AND OTHER SUCH WORK E MAY BE NECESSARY TO UNDER ALL PARALLEL WALLS AND PARTITIONS,AND SIDING.SEE ELEVATIONS. EXCAVATE FOR ALL FOOTI]VGS,FOUNDATION WALLS, GRADE N-1. 2'x4"WOOD STUDS.SEE RIGID INSULATION. Drawn By Checked By THE DEPTHS AS SHOWN ON THE DRAWINGS.ALL INSTALLATION SHALL FOLLOW NATIONAL CONCRETE AT CANTILEVERS BEYOND THE FOUNDATIONS WALL. DIVISION 7 1/2^GYPSUM WALLBOARD CONSTRUCTION PLAN. T2"Off HOUSE WRAP OR EQUAL. TRENCHES FOR FOOTINGS,FOUNDATIONS,SLABS, MASONRY INSTITUTE'S RECOMMENDATIONS. THERMAL AND MOISTURE PROTECTION: 11 EXT.GRADE PLYWOOD. UNDISTURBED TYPICAL INTERIOR NEW,NON-BEARING PARTITIONS J.E.M. "E"�" �"E"�" ETC. SHALL HAVE LEVEL,SOLID AND BOTTOMS. LAY WALLS IN RUNNING BOND PATTERN,UNLESS SHALL BE 2X4 STUDS AT 16"O.C.WITH 5/8" ROOFING: OTHERWISE INDICATED. SHEETROCK. TAPE,SPACKLE AND FINISH AS DIMENSIONAL ASPHALT ROOFING SHINGLES,COLOR Drawing No. ALL SOIL BEARING CAPACITY ASSUMED AT 2 TONS/ SPECIFIED. AS SELECTED BY OWNER AND ARCHITECT. 2X4 EXTERIOR WALL WITH VINYL SIDING A-4 SQUARE FOOT,CONTRACTOR SHALL VERIFY INFIELD. DO NOT USE LESS THAN ONE HALF-MASONRY SCALE: 3/4"=1'-O" MODULE. TYPICAL EXTERIOR WALLS:NEW CONSTRUCTION INSULATION: i SHALL BE 2X6 AT 16"O.C. FILL USED OR ENCOUNTERED UNDERNEATH Sheet ) of 5 •►. ., i AIW L _ LLB' 3. : Y Y 6 Y 4� I Y I