HomeMy WebLinkAbout1000-10.-9-13 OFFICE LOCATION: F S 0 MAILING ADDRESS:
Town Hall Annex P.O. Box 1179
54375 State Route 25 Southold, NY 11971
(cor. Main Rd. &Youngs Ave.)
Southold, NY 11971 Telephone: 631 765-1938
C
LOCAL WATERFRONT REVITALIZATION PROGRAM
TOWN OF SOUTHOLD
To: Leslie Kanes-Weisman, ZBA Chairperson
Members of the Zoning Board of Appeals
Cc: Julie McGivney, Assistant Town Attorney
Glenn Goldsmith, President, Board of Trustees
From: Heather Lanza, AICP, Planning Director
LWRP Coordinator
Date: October 26, 2026
Re: LWRP Coastal Consistency Review
GARCELON, SCTM# 1000-10.-9-13
ZBA File Ref. No. #8142
This application is a request for a variance from Article XXXVI Section §280-208. The
Building Inspector's March 17, 2026 Notice of Disapproval, revised October 1, 2026, is
based on an application to construct a new single-family dwelling with a rear deck on a
vacant parcel on West Harbor, Fishers Island, where the building is beyond the limits of
the sky plane.
The proposed action has been reviewed to Chapter §268, Waterfront Consistency
Review of the Town of Southold Town Code and the Local Waterfront Revitalization
Program (LWRP) Policy Standards. Based upon the information provided on the LWRP
Consistency Assessment Form submitted to this department, as well as the records
available to me, it is my recommendation that the proposed action is INCONSISTENT
with the policies of the LWRP as follows:
Policy 1. Foster a pattern of development in the Town of Southold that enhances
community character, preserves open space, makes efficient use of infrastructure,
Garcelon LWRP
makes beneficial use of a coastal location, and minimizes adverse effects of
development.
Policy 4. Minimize loss of life, structures, and natural resources from flooding and
erosion.
4.1 Minimize losses of human life and structures from flooding and erosion hazards.
A. Minimize potential loss and damage by locating development and structures
away from flooding and erosion hazards.
1. Avoid development other than water-dependent uses in coastal hazard
areas. Locate new development which is not water-dependent as far away
from coastal hazard areas as practical.
b. Avoid hazards by siting structures to maximize the distance from
Coastal Erosion Hazard Areas.
c. Provide sufficient lot depth to allow relocation of structures and
maintenance of required setbacks over a period of thirty years.
2. Avoid reconstruction of structures, other than structures that are part of a
water-dependent use, damaged by 50% or more of their value in coastal
hazard areas.
3. Move existing development and structures as far away from flooding and
erosion hazards as practical. Maintaining existing development and structures
in hazard areas may be warranted for: ... d. sites where relocation of an
existing structure is not practical.
Policy 5. Protect and improve water quality and supply in the Town of Southold.
5.1 Prohibit direct or indirect discharges that would cause or contribute to contravention
of water quality standards.
C. Ensure effective treatment of sanitary sewage and industrial discharges by:
8. providing and managing on-site disposal systems:
b. protect surface and groundwater against contamination from pathogens
and excessive nutrient loading by keeping septic effluent separated from
groundwater and by providing adequate treatment of septic effluent,
Policy 6. Protect and restore the quality and function of the Town of Southold's
ecosystem.
6.3. Protect and restore tidal and freshwater wetlands.
2
Garcelon LWRP
A. Comply with statutory and regulatory requirements of the Southold Town
Board of Trustees laws and regulations for all Andros Patent and other lands
under their jurisdiction.
D. Provide adequate buffers between wetlands and adjacent or nearby uses and
activities in order to ensure protection of the wetland's character, quality, values,
and functions.
The 6,490 sq. ft. parcel is vacant lawn with an existing dock and a stone revetment
along West Harbor. It is a pre-existing non-conforming lot, and is only 16% of the
40,000 sq. ft. minimum lot size in the R-40 zoning district. The tidal wetland boundary
(apparent high-water line) runs along the revetment at the rear property line. Grade is
approximately EL 5.7' to 6.1'. The parcel is located entirely in FEMA flood zone VE
(Flood Insurance Rate Map panel 36103C0019H, September 25, 2009). The survey
shows base flood elevations of 13' and 14', and the Suffolk County Geographic
Information System flood zone layer shows 14' at the center of the parcel. The first floor
is proposed at elevation 15.5' on piers. The Coastal Erosion Hazard Area line crosses
the northwest part of the parcel, seaward of the proposed deck.
The sanitary plan by CHA (Pete Parent, P.E.) reports a test hole observed on July 22,
2025 and updated November 20, 2025. Groundwater was encountered 84" (7') below
grade, the expected seasonal high groundwater is at EL 0'. The proposed Fuji Clean
CEN-5 I/A OWTS discharges to six leaching galleries with bottoms at elevation 2.0%
which the plan describes as an alternative system for high groundwater.
An earlier version of this proposal (ZBA File #8071) was found INCONSISTENT with the
LWRP in the January 7, 2026 recommendation, and the variances were denied on
February 5, 2026. The new design has a smaller 37' x 25' footprint with a 37' x 10' deck,
meets the setbacks and lot coverage (19.95%, where 20% is permitted), and requires
only the sky plane variance. The gross floor area is 2,008 sq. ft. (2,100 sq. ft. permitted),
up from the 1,828 sq. ft. described in the June 2026 submission.
Town Code §275-3 "Findings, purpose; jurisdiction; setbacks" states the following:
D. Setbacks.
(1) The following minimum setbacks apply to any and all operations proposed
on residential property within the jurisdiction of the Board of Trustees:
(a) Wetland boundary or bank.
[11 Residence: 100 feet.
The proposed action is recommended as INCONSISTENT for the following reasons:
1. The action places new, non-water-dependent development on a vacant parcel in
the most hazardous flood zone mapped on the coast (Policy 4.1 A 1).
3
Garcelon LWRP
• Zone VE: Both FEMA and Southold Town Code (§148-4 Definitions)
designate Zone VE as the Coastal High Hazard Area, where the base flood
(the flood with a 1% chance of being equaled or exceeded in any year)
carries breaking waves 3' or higher. The base flood elevation of EL 13' to 14'
includes the wave crest. Ground at the site is about EL 6', so the base flood
would put roughly 7' to 8' of moving water, including waves, across the parcel.
A 1% annual chance flood has about a 26% chance of occurring at least once
over a 30-year period. Zone VE is also defined in Town Code §148-4.
• Future hazard: Building on piers with breakaway walls meets the building
code, but it does not remove the hazard. Wave impact, scour around the pier
foundations and waterborne debris can damage or destroy an elevated house
in a storm that exceeds the design conditions. A destroyed house becomes
debris that is carried into West Harbor, the adjacent tidal wetland and the
neighboring homes. Placing a new structure in Zone VE creates that future
hazard where none exists today. The LWRP also discourages rebuilding a
non-water-dependent structure that is damaged by 50% or more in a coastal
hazard area (Policy 4.1 A 2).
• Sea level rise: The 2009 flood map is based on historical water levels and
does not account for sea level rise. New York State's adopted projections for
the Long Island region (6 NYCRR Part 490, 2024) estimate a rise of 18" by
the 2050s and 39" by 2100 under the medium projection, and 41" by the
2080s under the high-medium projection, above the 1995-2014 baseline. The
proposed first floor is only 1.5 to 2.5' above the mapped base flood elevation.
Under the medium projection that margin would be largely or entirely used up
by the 2050s and exceeded by 2100, within the expected life of the house.
Because the same storm produces higher water on a higher sea, flooding
below the base flood level will also reach this low parcel more often, and the
depth of water and the wave heights it can support will increase over time.
• Lot depth: The parcel is roughly 82' to 102' deep, and the house is about 41'
from the water. The lot is not deep enough to move the house landward as
the shoreline and flood levels change over the next thirty years (Policy 4.1 A 1
c), and the house cannot be sited farther from the Coastal Erosion Hazard
Area (Policy 4.1 A 1 b).
• Neighboring houses: The Board's February 5, 2026 decision on File #8071
found that the area homes were developed well before zoning and do not
meet today's Zoning Code. They were built before current flood standards
and sea level rise projections. Policy 4.1 A 3 allows existing structures to be
maintained where relocation is not practical, however it does not support
adding new development to a hazard area. The presence of existing houses
in Zone VE does not justify adding another. Each new house increases the
number of people and structures exposed to the hazard and the debris a
storm can generate.
4
Garcelon LWRP
2. The sanitary system is likely to fail from flooding and high groundwater (Policy
5.1 C 8 b; Policy 5.3 A).
• Groundwater: The leaching galleries are only 2' above the expected
seasonal high groundwater. Groundwater near the shoreline rises with sea
level, so this separation would shrink to about 6" with the 18" of rise projected
by the 2050s and would be lost before 2100.
• Flooding: The base flood would put 7' to 8' of water over the treatment unit,
distribution box and leaching galleries. Saturated leaching areas cannot treat
effluent, and floodwater can enter the tank and damage the blower, pump and
alarm controls of an I/A system, allowing untreated wastewater with
pathogens and nitrogen to reach West Harbor (U.S. EPA, 2024).
3. The lot is far too small for new development in this location. At 6,490 sq. ft., it is
about one-sixth of the 40,000 sq. ft. minimum lot size in the R-40 district. The
dwelling, deck, I/A system, parking and drywells fill the parcel, with the lot
coverage at 19.95% and the gross floor area at 2,008 sq. ft., close to the 20%
and 2,100 sq. ft. limits. There is no room for a meaningful buffer from the wetland
or to relocate structures away from the hazard (Policy 1; Policy 4.1 A 1 c).
4. The deck is proposed approximately 31' and the dwelling approximately 41' from
the tidal wetland boundary, where 100' is required (Town Code §275-3
D(1)(a)[1]; Policy 6.3 A). Nearly the entire parcel is within 100' of the wetland, so
there is no location on the lot where a dwelling could meet the setback.
5. The parcel is undeveloped. The action adds a dwelling, deck, sanitary system,
parking and utilities next to the tidal wetland. (Policy 6.3 D).
The variance can easily be avoided by a change of design, and is recommended to be
denied.
If the roof is redesigned to fit within the sky plane, no variance would be needed. Zoning
compliance, however, would not resolve the LWRP inconsistencies described above.
The action is also in the jurisdiction of the Board of Trustees, which must make its own
consistency determination under Chapter 268 and must approve a wetland permit
before the dwelling can be built. The Board of Trustees tabled its November 12, 2025
hearing pending the Zoning Board of Appeals review.
Town Code Chapter 275 provides the Southold Town Board of Trustees with a rational
basis for denying the wetland permit because of the dwelling's location in the VE flood
zone. The stated purpose of the chapter includes the "prevention of flood damage by
limiting development in flood hazard areas" (§275-3 B). Town Code §275-12 states that
the Trustees may issue a permit "only if it determines that such operations will not
substantially:"
E. Increase the danger of flood and storm-tide damage
5
Garcelon LWRP
1. Otherwise adversely affect the health, safety and general welfare of the people
of the Town.
The entire parcel is in the Coastal High Hazard Area (not to be confused with the
Coastal Erosion Hazard Area). Adding a new dwelling and sanitary system in the
Coastal High Hazard Area (Zone VE), a location that will flood more often and more
deeply as sea level rises, increases the danger of flood and storm-tide damage to the
dwelling, and the neighboring homes. And the periodic flooding of the septic system by
storms and impending sea level rise will adversely affect the health and general welfare
of the people of the town by causing pollution of West Harbor from untreated septic
effluent.
Pursuant to Chapter 268, the Zoning Board of Appeals shall consider this
recommendation in preparing its written determination regarding the consistency of the
proposed action.
6