Loading...
HomeMy WebLinkAbout32389-Z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-31920 Date: 10/18/06 THIS CERTIFIES that the building STOVES Location of Property: 4505 ALVAHS LA CUTCHOGUE (HOUSE NO.) (STREET) (HAMLET) County Tax Map No. 473889 Section 101 Block 2 Lot 23 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated SEPTEMBER 14, 2006 pursuant to which Building Permit No. 32389-Z dated SEPTEMBER 26, 2006 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is "AS BUILT" INSTALLATION OF A WOOD BURNING STOVE & DIRECT VENT GAS HEATER IN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR. The certificate is issued to LISA E CALLAGHAN & PATRICK METTES (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A ELECTRICAL CERTIFICATE NO. N/A PLUMBERS CERTIFICATION DATED N/A 0 Authorized Signature Rev. 1/81 < 1 b S, Form No.6 TOWN OF SOUTHOLD 3 BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Depart gnt;Zthmthe'following: A. For new building or new use: i 1. Final survey of property with accurate location of all buildings,property lines, stree s, and unusual natural or topographic features. `------ 1> �ap ninr i1. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form) T�bti r: aOUT�IOLD 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses,or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$25.00, Additions to dwelling$25.00, Alterations to dwelling$25.00, Swimming pool $25.00, Accessory building$25.00, Additions to accessory building$25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00, Commercial$15.00 Date. New Construction: Old or Pre-!existing Building: i�I (check one) Location of Property: O As tift415 v ne—A D v€ /()� House No�t,,T- Street Ham et Owner or Owners of Property: ('_1 G V I &-rT s Suffolk County Tax Map No 1000, Section /O f Block Lot Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: XT l'- 1 Ck -T-rJE S Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: `/ (check one) Fee Submitted: $ 7. Applicant Signature f�� co-� 319�D FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 32389 Z Date SEPTEMBER 26, 2006 Permission is hereby granted to: LISA E CALLAGHAN NEW YORK,NY 10025 for "AS BUILT" INSTALLATION OF A WOOD BURINING STOVE & DIRECT VENT GAS HEATER IN A ONE FAMILY DWELLING AS APPLIED FOR PER MANUFACTURER SPECIFICATIONS at premises located at 4505 ALVAHS LA CUTCHOGUE County Tax Map No. 473889 Section 101 Block 0002 Lot No. 023 pursuant to application dated SEPTEMBER 14, 2006 and approved by the Building Inspector to expire on MARCH 26, 2008 . Fee $ 300 . 00 2 A or'i d -� ORIGINAL Rev. 5/8/02 _ �� TOWN OF SOUTHOLD' PROPERTY RECORD CARD OWNER STREET Ljt`�"�� ,, VILLAGE DIST. SUB. LOT ice.0�6 . , E- Cat a a/1 � r FORMER OWNER N' / %��!// E f A . . /r L �: . S W TYPE OF BUILDING ,ES. �/v SEAS. VL. FARM COMM. CB. MISC. Mkt. Value LAND IMP. TOTAL DATE REMARKS q D d Q �� LI1 04 ao1 &Arn5 ks+, - 1 Gks o e o .�� o o 0C3 31,,ql zz a qg- riot - ., v - AGE BUILDING CONDITION NEW NORMAL' BELOW ABOVE FARM Acre Value Per Value Acre billable 1 f illable 2 "illable 3 Voodland ;wampl,and FRONTAGE ON WATER irushland FRONTAGE ON ROAD louse Plot DEPTH , BULKHEAD 'otal DOCK 00, MEN ■■■■■■ ■.I■■■■■■■■■■■■■■■■■■ �js` _ d t�gig r e Sqi ■■■■■NO E.■■■■■■■■■■■■■■■■■■ ; -{ ■■■■ ■ ■M■■■■■■■■■■■■■■■■■ ■■■■■■■ ■M■M■■■■■■■■■■■■■■■ NA J! • • Interior Fire Place Rooms I st Floor Rooms 2nd Floor: r, I a f, OF SOpjyOlo `. cout�v, TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING �INAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION REMARKS: r DATE INSPECTOR i FIELD INSPECTION REPORT DATE COMMENTS IN�' FOUNDATION(1ST) ------------------------------------ Lp LA FOUNDATION(2ND) -9 z 0 4- ROUGH FRAMING& C) PLUMBING r f�fn V' INSULATION PER N.Y. ' STATE ENERGY CODE QR FINAL ADDITIONAL COMMENTS Z m Cti � O x -max ro y I TOWN OF SOUTH,OLD. BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631).765-9502 Survey www. northfork.net/Southold/ PERMIT NO. 3 Check Septic Form N.Y.S.D.E.C. Trustees Examined 9 o2C ,20 .6 Contact: ��// Approved `� �Z� ,20� Mail to:�o% r /� Disapproved a/c -"Building 4f90- h -J eV7, Phone: 76�l� 9D Expiration g p1 u� L. P,!_oG.')ePT. �U i"HOLD APPLICATION FOR BUILDING PERMIT Date q l , 20 mG INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months.Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws,Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations, and to admit authorized inspectors on premises and in building fdr necessary inspections. f (Signature of applicant or name,if a corporation) AP RO ED AS NOTED ` DATE: B.P.# (Mailing address of appl cant) StateN agent, architect, engineer, general contractor, electrician,plumber or builder 8,AM TO 4 PM. FOR THE � I��011lld� INSPECTIONS: , 1. FOUNDATION ,- TWO REQUIR Name ofaRvNYJol�if�flTE rAl( 2. ROUGH - FRAMING, & PLUM (As on the tax roll or latest deed) If ap�i 4. FINAL IiATJW TRUCTna_$i tnre of duly authorized officer AL i paiMo ,o Eer) OCCUPANCY OR REQUIREMENTS OF THE CODES OF NEW Build kig"TFNP0T RESPONSIBLE FOR USE IS UNLAWFUL; PlumbMdWcWsC6MSTRUCTION ERRORS. Electricians License No. WITHOUT.CERTIFICATE Other Trade's License No. OF OCCUPANCY 1. Locaf n of land on which proposed work will be done: Ho se Number Street Hamlet County Tax Map No. 1000 Section 10 —Block-9— Lot oZ 3 Subdivision Filed Map No. Lot (Name) • i 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy ,,//f Tr b. Intended use and occupancy AA77 C WC'/ 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work P/&L'061 d A �07X-1- (Descrip ion) 4. Estimated Cost Fee ��( /a/ 9/a ds� (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 4 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. / 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of-Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO -/ Will excess fill be removed from premises? YES NO 14. Names of Owner of premise C'i'TcS Address k-09%WZ14fff Phone No. -31-73�'- ��97 Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTY OF�� P/1g—( k being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S�Ie`is the (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements do aant d;in,t s pplic ton,are true to the best of his knowledge and belief, and that the work will be performed,ii the e�setorth dn,tlip a }1�ication filed therewith. p��lpnj��U*��f Sworn to before me l- �j J 1�day of ` ° a_ J201�d� Notary P is Signature of Applicant LQRRAME KLOPFER 7 Notary Public,State of New York No.4828373 Qualified in Suffolk County commission Expires Nov.30,C �/Q S F 'III o a Y _ w W M\A/- [1 N T J Defiant Woodburning Stove �y Model 1945 Homeowner's 0 o Installation and Operating Manual o For use in'the 0968 United States and Canada SAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERLY INSTALLED, 1 OPERATED AND MAINTAINED,A HOUS� FIRE MAY RESULT. 9 TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS. j FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH. CONTACT LOCAL BUILDING OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA. • Not Discardfor Future Use 30001693 6/02 Rev.2 Vennoht Castings Defiant Congratulations on'your choice of a Vermont Castings Defiant stove.With this purchase you have made�a.commit- ment to make the hearth a place of warmth, beauty and comfort in your home.At Vermont Castings,'we share that joy and appreciation for the hearth. We assure you that your cast-iron Vermont Castings stove has been made with the utmost care and will provide you with many years of service. As you become acquainted with your new stove,,you will find that its appearance is matched,by its functionality, due to cast iron's unique ability'to absorb and radiate heat. Also, Vermont Castings products are among the cleanest-burning wood stoves and fireplaces available today.As an owner of.a Vermont Castings stove, you make a strong statement for.pollution-free energy. However,,clean burning I depends on both the-manufacturer and the operator. Please'read this manual carefully to understand how to properly operate and maintain your stove. At Vermont Castings, we are equally committed to your satisfaction as'a customer.That is why we maintain an exclusive network of the finest dealers in the industry. Our dealers are chosen for their expertise and dedication to customer service.They are factor.-trained and knowledgeable about every Vermont,Cast!ngs product. Feel free to contact your Authorized,;Vermont Castings Dealer anytime you have a particular question about your stove or its performance. ` This manual contains valuable instructions on the installation and operation of your Vermont Castings Defiant..It also contains useful information on maintenance. Please read the manual thoroughly and keep it as a reference. Sincerely, All of Us.at Verm on t.Castings This manual describes the installation, operation, and maintenance of the Vermont Castings Defiant Model 1945 catalytic-equipped wood burning heater. This heater meets the U:S. Environmental Protection Agency's emission lirnits.for wood heaters sold on or after July 1, 1990. ,Under specific,test conditions this heater has been'shown to deliver heat at rates ranging,from 10,600 to 55,000 Btu/hr. The Defiant Model 91945 has been tested and is listed by Canadian Standards Association (CSA).The test stan- dards are ANSI/,UL-1482 and ANSI/UL-737 for the United States, and ULC S627 and CAN/CSA-6366.2 for Canada. The Defiant is listed for burning wood only. Do not burn other fuels. The Defiant is approved for use in manufactured (mobile) homes only in the United States, and only when installed with Vermont Castings Mobile Home Kit No. 1900. We recommend that you hire a professional'installercertified by the Wood Heat Education and Research Foundation (WHERF) or the Wood Energy Technical Training.(WETT) to install your stove, or to advise you on the installation should you attempt to install it yourself. Please read this entire manual before you install and use your new stove. Failure to follow instructions may result in property damage, bodily injury, or even death. FutureSave These instructions for Reference 2 Vermont Castings Defiant The Story of the Defiant No wood-burning appliance, save for Ben Franklin's Pennsylvania Fireplace, has a stronger heritage than the Ver- mont Castings Defiant. Named for a 19th-century steamship, the original Vermont Castings Defiant Wood Stove came to epitomize America's resolve and independence during the Energy Crisis of the 1970s. The year was 1975. With energy prices going through the roof, and not an attractive or efficient wood stove to be found anywhere, two entrepreneurs set out to create a stove that was a thing of beauty as well as utility. Finely crafted from cast iron,.the Defiant was the first wood stove to combine an artistically designed exterior with a methodically engineered interior, using new technologies for efficient combustion. Americans purchased over a quarter-million Defiants, as they rediscovered the common sense of heating with wood, a home-grown fuel with none of the political and economic entanglements of foreign oil. Thirteen years later, in 1988, Vermont Castings 'retired'the Defiant, replacing it with modern wood-burners such as the Encore. With its 1998 return, the new Defiant incorporates all the finest aesthetic, convenience, and performance features to be found on any wood stove. In a sense, the new Defiant has-been 23 years in the making. Due to its significant role in American history, the original model Defiant is in the permanent collection of the Smithsonian Institution. Each new purchase of the Defiant stove continues that history. Table Specifications .................................... 4 #1560 Warming Shelf Installation 5 #1900 Mobile Home Kit """"""""""""""""""""' #1904 Outside Air Adaptor Clearance Charts 14 #1905 Bottom Heat Shield Kit #1901 Rear Heat Shield Kit Assembly......................................... 18 #1907 Firescreen Operation #1860 6" x 12"Oval Starter Pipe ........................................ 19 Maintenance.................................... 29 A line of porcelain enamel stove pipe is available in Sand, Moonlight, and Forest Green colors. Appendix: Catalytic Combustor....::. 35 Appendix: Chimney & Fireplace Hazards ... 36 Parts Diagram ................................. 37 I . Vermont Castings Defiant Specifications Defiant, Model 1945 Range of heat output.......... 10,600 to 55,000 Btu's/hr.* `This value can vary depending on how the stove is' Maximum heat output....................:...55,000 Btu's/hr.** operated,the type and moisture content of the fuel Area heated............................ Up to 2,400 Square feet used, as well as the design, construction and climatic Fuel Size/type ................................. 22 -24"hardwood location of your home. Figures shown are based on I Fuel capacity.....:...: ...................:.................50 pounds maximum fuel consumption obtained•under laboratory Loading ..........:..........................................: Front or top conditions and on average efficiencies. Chimney Connector: These values are based on operation in building for 8"flue collar..................... 8" (200mm) diameter code-conforming homes under typical winter climate Chimney Flue Size: conditions in New England If your home is of nonstand- with 8" Chimney Connector . 8" (200mm) minimum and construction'(e.g. unusually well insulated, not. "Chimney Connector . 6" (150mm) minimum insulated,:built underground, etc.)or if.you live in a Flue xits position ........ ................................To Rear P p or more severe or more temperate climate, these figures Primary Air...Manually set, thermostatically maintained may not apply. Since,so many variables.affect perfor- Secondary Air..................:..........::.....:... Self-regulating mance consult your Authorized Dealer to determine Ash handling system.....................Removable ash pan , realistic expectations for your home. Glass panels ....................... High-temperature ceramic U.S. and foreign design'and mechanical patents Weight ...... 480 lbs. (220kg.) pending. Width (leg to leg)......................................33" (826mm) Depth.(leg to leg)................................... 191/2" (362mm) Height to top of flue collar .....................301/2" (775mm) Drawing Not to Scale 21W 16'/4 546mm) (464mm) I• '23'W 31' 21'/� 31', (591mm) (96mm I L 546mm 71 —+{ ' � DDIIANT D�IIANT , 2T (737mm)' 28'fi• .(768mm)> (724 mm) (654mm) 0 0 it - 19'/i �I 19'/i �I 32'/i (489mm) I (489mm) (826 mm) 1693 Fig. 1 Defiant dimensions. 4 Vermont Castings Defiant, Installation SAFETY'NOTICE: IF YOUR DEFIANT IS,NOT Ou Air tside PROPERLY INSTALLED, A HOUSE FIRE MAY In some modern, super-insulated homes, there is RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS. inadequate air supply for combustion because of CONTACT LOCAL BUILDING OR FIRE OFFICIALS insufficient air infiltration into the building. Such air ABOUT RESTRICTIONS AND INSTALLATION . enters a home through:unsealed cracks and-openings. INSPECTION'REQUIREMENTS IN YOUR AREA. Exhaust fans for kitchen or bath can compete with the stove for available air and compound the problem. Before,you begin an installation,'be sure that: Your stove and chimney connector will be far When poor draft.is caused by a low infiltration rate, • opening a ground floor window on the windward-side of enough.from combustible material to meet all the house and near the stove will usually alleviate the clearance requirements. problem. . • The floor protector is large enough and is con- structed properly to meet all requirements. A better solution is to install a permanent outside air You have all necessary permits from local authori- supply-to the stove and/or room. In fact, bringing air for I combustion from outside the home directly'to the air inlet ties. of the stove is required.for new construction in some { Your.local building official is the final authority for areas. l approving your installation as safe and determining that Pressure variations within the house do not affect a it meets local and state codes: stove equipped with an outside air supply, and im- The metal label permanently attached to the back of proved stove performance often results. An Outside Air every Vermont Castings' stove indicates that the stove Adaptor Kit for the Defiant is available from your local has been tested to current UL and ULC,standards, and dealer. i gives the name of the testing laboratory.' Clearance and installation information also is printed on the label. Chimney Height When the stove is installed according to the information both on the label and in this manual, local authorities Altitude affects chimney performance. When using an usually will accept the label as evidence.that the S".oval to,.6" flue collar adapter on the Defiant, refer to.. installation meets'codes and can be approved. Figure 1 for suggested chimney heights at various altitudes. Chimney height should.be measured from the However, codes vary in different areas. .Qefore,starting flue collar to the top of the chimney.The recommended the installation, review your plans with the local building minimum chimney height is 16 feet.(5 meters). authority. Your local dealer can provide any additional information needed. For any unresolved installation issues„refer to the National Fire Protection Association's publication ANSI/ NFPA 211 Standard for Chimneys, Fireplaces, Vents 30 and Solid Fuel Burning Appliances. For Canada, the _ equivalent publication is CSA CAN-B365 Installation Code for Solid Fuel Burning Appliances and Equipment. 25 These standards are the basis for many national codes: 2, They are nationally recognized and are accepted by = 20 most local authorities. Your local dealer or your local building official may have a copy of these regulations. 15 IMPORTANT: Failure to follow these installation instructions may result in a dangerous situation, 0 2000• 4000 6000 8000 10000 12000 including a chimney or house fire. Follow all instructions exactly, and do not allow makeshift sTasi Altitude compromises to endanger property and personal safety._ Fig.2 Chimney height requirements with 6"chimney and/or chimney connector. 5 Vennont Castings DefiantWhat ` d of Chimney Masonry Chimneys You must'connect the Defiant to a code-approved An inspection of the.chimney must confirm that it.has a masonry chimney with a flue liner, to a rel'ined•masonry lining. Don ot use an unlined chimney. The chimney chimney that meets local.codes, or fo a prefabricated must have no cracks, loose mortar, other signs of metal chimney that complies with the requirements for deterioration, or blockage. Repair any defects before Type HT chimneys.in the Standard for Chimneys, using the chimney with your stove. Factory-Built,Residential Type.and Building Heating Seal any unused,openings in an existing masonry Appliance, UL 103. Figure 3 illustrates the two types. chimney with masonry to the thickness of the chimney The chimney and chimney connector must be in good wall, and repair the chimney liner. Openings sealed condition and kept clean. with pie plates or wallpaper are a hazard and must be If you use an existing masonry chimney, it must be sealed with mortar or refractory cement. In a chimney inspected to ensure it is in a safe condition before the fire, flames and smoke may be forced out of these stove is installed. Your local.professional chimney unused thimbles. sweep, building inspector, or fire department official will The chimney should be thoroughly cleaned before use. be able to inspect the chimney or provide a referral to A newly-built masonry chimney must conform to the: someone who can: See 'Chimney and Fireplace standards of your local building,code or, in the absence Hazards', in the appendix,,for particulars. of a local code, to a recognized'national code. Mal' sonry chimneys must be lined, either with code- A prefabricated double- pp mason approved ry wall insulated`chimney ' masonry or pre-cast refracto tiles, stainless steel pipe, or a code-approved, "poured-in-place" liner. `--� The chimney's clean-out door must seal tightly.A loose or leaky clean-out door can weaken chimney draft to the stove, causing performance problems. , Prefabricated Chimneys A the-lined A prefabricated metal chimney must be one tested and masonry listed for use with solid-fuel burning appliances to the chimney High-Temperature (H.T.) Chimney Standard UL-103- 1985 (2100°F.) for the United States, and High sT241 Temperature (650°C) Standard ULC S-629 for Canada.. Fig.3 Approved chimney types. DO NOT CONNECT THIS UNIT TO A CHIMNEY The chimney must extend at'least 3' (900 mm) above FLUE SERVING ANOTHER APPLIANCE. the highest point where it passes through or past a Chimney _ roof, and at least 2' (600 mm) higher than any part of a building within 10' (3 m) horizontally. (Fig. 4) The Defiant is approved for venting into a masonry. For proper draft and good performance, any chimney chimney with a nominal flue size of 8" x 8" (200 x 200, used with a Defiant should extend at least 16 feet (5 mm) or 9"x 12" (200 x 300 mm), and into a round flue m) above the flue collar of the stove. with nominal flue size of 8" (200 mm). A Defiant with a 6" (150 mm) flue collar adapter is approved for venting 0 TO 10'—►! into a masonry chimney with a nominal flue size of 8"x 8" (200 x 200 mm), and into'a round flue with nominal 2'Mir— flue size of 6" (150 mm). Min. 1' NOTE: When installed with a 6" chimney connector i 2'Min. 3 adapter, the Defiant may not be operated with the Min. l front doors open. . . I The Defiant may be vented into larger chimneys as well. However, chimneys with liners larger'than 8"x 12" Reference (200 x 300 mm)may experience rapid cooling of.,smoke.. Point and reduction in draft, especially if the chimneys are ncs» located outside the home.These,large chimneys may Fig.4 The 2'410'Chimney Rule. need to be insulated or have their flues relined for proper stove performance. 6 Vermont Castings Defiant Accessories to help make the connection between Fasten each joint between sections of chimney stainless steel chimney liners and your Defiant are connector, including telescoping joints, with at least available,through your local dealer. three sheet metal screws. Holes in the top of each _ Guidelinesctor section of'chimney connector serve as guides when Chimney Connyou drill 1/8"(3 mm) holes in the bottom of the next A chimney connector is the single-wall pipe that'., section: connects the stove to the chimney. The chimney itself Fasten the chimney iis the masonry or prefabricated structure that encloses connector to the Toward the flue. Chimney connectors"are used only to connect chimney. Instruc' stove the stove to the chimney. tions for various Single-wall connectors should be made of 24 gauge or installations follow. heavier steel. Do not use galvanized connector; it cannot Figure 5 illustrates. , withstand the high temperatures that smoke and exhaust the general layout ases can reach,:and'ma release toxic fumes under of chimney connec- I .:. 9 . Y. Flue Gas A high heat._ The connector may be 6"(150 mm)or 8" (200 for parts. Direction I mm) in diameter. o Be sure the installed If possible, do.not pass'the,chimney connector through stove and chimney St242 a combustiblemall or ceiling. If passage through a connector are combustible,wall.is unavoidable, refer to the section'on correct distances Fig.5 Chimney connector. Wall Pass-Through's. Do not pass the connector from nearby combustible materials. through an attic, a.closet or similar concealed space. NOTE:.Special slip pipes and thimble sleeves that form The whole connector should be exposed and.acces- telescoping joints between sections�6f chimney connec- sible for inspection and cleaning. for are available to simplify installations.They often In horizontal runs of chimney connector, maintain a eliminate the need to cut individual connector sections. distance of 24" (610 mm)-from the ceiling.-Keep it as Corisult.your local dealer about these special pieces. short and direct as,possible, with no more than two 90 Securing _ Single Connector degree turns. Slope horizontal"runs of connector, upward 1/4" per foot (20 mm per meter) going from thePrefabricated Chimney stove toward the chimney.The recommended maxi- . Follow the installation instructions of the chimney mum length of a horizontal run is 3 feet(1 meter), and manufacturer exactly as you install the chimney. The the total length of the chimney connector should be no manufacturer of the chimney will supply the accesso- longer than 8 feet (2.5 meters). In cathedral ceiling Ties to support the chimney, either from the roof of the installations, extend the prefabricated chimney down- house, at the ceiling of the room where the stove is ward to within 8 feet ,(2.5 meters) of the stove.This will installed,or from an exterior wall. help maintain a good draft by keeping the smoke warm, Special adaptors are available from the chimney so that it rises readily. manufacturer,to make the connection between the Wear gloves and protective eyewear when drilling, prefabricated chimney and the chimney connector. cutting or joining sections of chimney connector. The top of such adaptors attaches directly to the _ chimney or to the chimney's ceiling'support package, Singl -wall Chimney Connectors while the ti'ottorn of the adaptor is screwed to the Begin assembly at:the flue collar of the stove. Insert chimney connector. . the first crimped end into the stove's flue collar, and These adaptors are designed so the top end will fit keep each crimped end pointing toward the stove. outside the inner wall of the chimney, and the bottom i Fig. 4. Use the holes in the flue collar as guides to' end will fit.inside the first section of chimney connector.. drill 1/8" (3:mm) holes in the bottom of the first' section of chimney connector and secure it to the flue collar with three#10 x 1/2" sheet metal screws. Lift off the griddle, and shield the stove's surface between the griddle opening and the front of the flue collar to protect the finish when.you drill the front hole. Vennont Castings Defiant i I Chimney Flue Thimble Sle Elbow Flue — Flue Inner Chimney Connector Slip Pipe -- � JI �� <— — Keep Standard Thimble sleeve i Connector end flush Oval to with flue Round Adaptor the Flue Collar ST243 Fig.7 The thimble, made of either ceramic or metal, must be cemented securely in place. Without a thimble, a suitable length of chimney connec- tor can be extended through the breach to the inner face of the flue liner, and cemented securely in place. ST492 Additional pieces of connector are then attached with Fig.6 An exploded view of the chimney connection in a sheet metal screws. I freestanding masonry installation. Fireplace Installations The chimney connector may be connected to the Masonry' Chimney chimney above the fireplace opening. Both freestanding masonry chimneys and fireplace. Above the Fireplace masonry chimneys may be used for your installation. The Defiant may be connected to a chimney above a Freestanding Installations fireplace opening. In such installations, the stove stands on the hearth in front of the fireplace and the If the chimney connector must pass through a combus- chimney connector rises from the stove top and then tible wall to reach the chimney, follow the recommen- • angles ninety degrees back into the chimney. The dations in the Wall Pass-Through section that follows. chimney liner should extend to the point at which the The opening through the chimney wall to the flue (the chimney connector enters the chimney. (Fig. 8) "breach") must be lined with either a ceramic or metal cylinder, called the"thimble", which is cemented securely in place. Most chimney breaches incorporate -� thimbles, but the fit must be'snug and the joint between _. Check These the thimble and the chimney wall must be cemented Clearances firmly. A special piece called the "thimble sleeve,"slightly, j smaller in diameter than standard connectors and most thimbles, will ease the removal of the chimney connec- tor system for inspection and cleaning. (Fig. 7) Thimble sleeves should be available from your local dealer. To install a thimble sleeve, slide it into the breach until it is flush with the inner flue wall. Don't extend it into the Mantel C� actual flue passage, as this could interfere with the draft. Seal This Off The thimble sleeve should protrude 1-2" (25-50 mm) M into the room. Use furnace cement and thin gasketing to seal the sleeve in place in the thimble. Secure the chimney connector to the outer end of the sleeve with sheet metal screws. �� ��• sr244a — Fig.8 In this installation, the chimney connector attaches to 8 the chimney above the fireplace opening. Vermont Castings Defiant If the chimney connector in your installation enters the Floor protection requirements also apply to fireplace chimney above a fireplace, follow all the guidelines installations. Refer to page 10. . mentioned above for freestanding installations. In addition, give,special consideration to the following ' hs points:_; Whenever possible, design your installation so that the • Check the clearance between the stove and the connector does not passe through a.combustible wall. If chimney connector, and any;combustible trim'or the you are considering a wall,.pass-through,in your, mantel.. installation, check with your building inspector before Check the clearance between the chimney connec- you begin. Also, check with the chimney connector 1 for and the ceiling. The clearance should be at least manufacturer for any specific requirements. 18" (457 mm). Accessories are available for use as wall pass- The fireplace damper must be sealed to keep room throughs. If using one of these, make sure it has been i tested and listed for use as a wall ass-throw h. air from escaping up the.flue. However, it must be P 9 possible to reopen the damper to inspect or clean In the United States,the National Fire Protection the chimney. Association (NFPA) has established guidelines for Through the Fireplace passing chimney connectors through combustible walls. Many building code inspectors follow these guidelines If your fireplace opening height is at least 29" when approving installations. .(737mm), you may install the Defiant through the ' opening using a"positive connection" kit,.available Figure 10 shows one NFPA-recommended method. All from.your local dealer.These positive connection kits combustible material in the wall is cut away from the ensure a tight fit between the stove flue collar and the single-wall connector to provide the required 12" (300 chimney flue as shown in Figure 9. mm) clearance. Any material used to close up'the opening must be noncombustible. Fireplace installation, whether connected to the flue above or through the fireplace opening, have special wall Stud clearance requirements to:adjacent trim and the mantel. You will find the required.safe clearances for I� the Defiant fireplace installation on Page 14. Chimney Connector ■ 0. � 12"of Flexible Noncombustible Connector ��� ■ Material �. Mantel Shield —�� '' =W, Floor . Fireplace Adaptor,. Protection Kit"Positive Connection" ST493 ��■ Fig. 10 An roved wall ass throu-h for the United States. 9• PP P . ..- 9 Three other methods are also approved by-the NFPA: �.. • Placing a section of chimney connector inside a ventilated thimble, which in turn is separated from j� combustibles by 6" (150 mm) of fiberglass insulating _ _ _ ___ ■� material. —J� Placinga section of connector inside a. Mfitltititi•titi•Mti•fi♦Mfi♦MM ST245 y section of 9"(230 mm) diameter, solid-insulated, Fig:9 Through the fireplace installation. factory-built chimney, with two inches of air space between the chimney section and combustibles.: 9 Vennont Castings Defiant • i • Using a section of solid-insulated double-wall High Protection Temperature chimney, with an inside diameter the Flo or same as the chimney connector, at least one inch of A tremendous amount of heat radiates from the bottom solid insulation, and a minimum of 9 inches (229mm) plate of your Defiant. The floor area directly under and air space,between the outer wall of the chimney around the stove will require protection from radiant section and combustibles. heat as well as from stray sparks or embers that may j In Canada,The Canadian Standards Association has escape the firebox. established different guidelines for wall pass-throughs. Heat protection is provided through the use of a Figure 9 shows one method, in which all combustible Vermont Castings Bottom Heat.Shield #1905. Spark material in the wall is cut away to provide the required and ember protection must be provided by a floor i 18" (460 mm) clearance for the connector. The protector constructed with noncombustible materials as resulting space must remain empty. A flush-mounted specified. II sheet metal cover may be used on one side only. If Most installations will require that the bottom heat covers must be used on both sides, each cover must shield be attached. Only when the stove is placed on a be mounted on noncombustible'spacers at least 1" (25 completely noncombustible surface such as unpainted mm) clear of the wall. .concrete over earth may it be used without the heat Your local dealer or your local building inspector can shield. ; provide details for other approved 'methods of passing Even when the bottom heat shield is installed, you a chimney connector through a combustible wall in must provide special protection to the floor beneath. your area. In Canada, this type of installation must For installation with the heat shield attached, use a conform to CAN/CSA-B365, Installation Code for Solid noncombustible floor protector such as 1/4" non- Fuel Burning Appliances and Equipment. asbestos mineral board or equivalent, or 24 gauge te• 11 sheet metal.The floor protector may be covered with a betweeenen pipe and ---)clearance noncombustible decorative material if desired. Do not sides/top/bottom of obstruct the space under the heater. opening ��-__ Protection requirements vary'somewhat between the ited States and Canada as follows: lV In U.S. installations, the floor protector is required v% under the stove and must extend at least 16 inches (not including the ash lip) from the front of the stove ('F', Fig. 12), and at least 6 inches from the sides and rear('D'and 'E', Fig. 12). It must also extend under the chimney connector and 2 inches to either side ('C', Fig. 12). For the 8" (200 mm) connector, the protector must be a minimum of 12" (300 mm) wide. For the 6" (150 mm) connector, the protec- tor for must be 10" (250 mm) wide. The protector must be Fig. 11 An approved wall pass-through for Canada. centered under the connector. NOTE: Do not vent your Defiant into a factory-built To meet these requirements, a floor protector must be (zero-clearance)fireplace.These appliances and their at least 42"wide and 43"deep. ' chimneys are specifically designed as a unit for use as In anada, a noncombustible floor protector is required fireplaces. It may void the listing or be hazardous to under the heater.also..The floor protector must extend adapt them for any other use. 18 inches (460 mm)to the'front ('F', Fig. 12), and 8 DO NOT CONNECT A DEFIANT TO ANY AIR inches (203 mm) from the sides and rear('D' and 'E', DISTRIBUTION DUCT OR SYSTEM. Fig. 12). To meet these requirements, a floor protector must be at least 46" (1168 mm) wide and 47" (1194 mm) deep. 10 Vermont Castings Defiant c Clearance is the distance between either your stove or chimney.connector, and nearby walls, floors, the ceiling, and any other fixed combustible.surface."The p Defiant has specific clearance requirements that have been established after careful research;and testing. B L These clearance requirements must be strictly ob- 'E► E E> E served. In addition, keep furnishings and other combustible F 'F• materials away from the'stove. In general, a distance of 48" (1220 mm) must be maintained between the stove n, and moveable combustible items such as drying u.s. Canada clothes, furniture, newspapers, firewood, etc. Keeping ' A. 42" 46"(1168mm) those clearance areas empty assures that nearby B. 43" 47" (1194mm) surfaces and objects.will not overheat. C. 12" 12'' (300mm) 8"Connector w 10"(250mm) : 6"+Connector SafeWaysto Reduce Clearances 6" 8" (203mm) Clearance requirements are established to meet every E. 6 8"(203mm) - F. 16" 18" (460mm) ST500 installation possibility, and'they involve the combina- Fig. 12.Required.floor protection dimensions. tion of these variables:' • .When the'stove has no listed heat shield Floor - Fireplace Installationmounted on it. Do not assume that your fireplace hearth..is'completely When the wall has no heat shield mounted on it. noncombustible. Many fireplace hearths do not satisfy • When the wall has a heat shield mounted on it. the "completely noncombustible' requirement because When the wall and stove have heat shields. the brick or concrete in front of the fireplace opening is In general, the greatest clearance is required when you supported by heavy wood framing. Because heat place a stove and its connector near a wall with no passes readily through brick or concrete, it can easily heat shield. pass through to the wood. As a result, such.fireplace hearths can be a fire hazard and are considered a For example, when the Defiant is installed parallel to combustible floor. the rear wall and no shield is used, it must be at least 33" (815 mm) from the wall behind it and at least 24" For all fireplace installations, follow the floor protection (610 mm) from walls on either side. guidelines described above. Keep in mind that many raised hearths will extend less than the required If the Defiant is installed in'a corner and no shield is clearance form the front of the heater. In such cases, used, the corners of the stove must be at least 23" (585 sufficient floor protection as described above must be mm)'from nearby walls. added in.front,of the hearth to satisfy the minimum Clearances may be reduced only by means approved floor protector requirement from the front of the stove: by the regulatory authority, and in accordance with the.` 16" (41 Omm) in the.United States and 18" (460mm) in clearances listed in this manual. Refer to Pages 10- 13 Canada. Hearth rugs do not satisfy the.requirement for for approved clearance reduction.specifications. floor protection as they are not fireproof. Use only Vermont Castings Defiant Rear Heat Shield Fireplace installation also have special clearance #000=1901. 1 . requirements to the side walls, side decorative trim and NOTE: Alcove installation of the Defiant is not fireplace mantel. Refer to the information on fireplace permitted. and mantel trim shields in this section. Shields StoveKeep the One way to reduce clearances is with a wall-shield Surrounding - constructed of 24 gauge or heavier sheet metal, or of Both a stove and its chimney connector radiate heat in another noncombustible materia®such as 1/2" (13�mm) insulation board such as Durock or Wonderboard , or: .all directions when operating, and nearby combustible common brick"laid on flat,"with the 3'/2",(90 mm) side materials can overheat dangerouslyif they are too down. close to the heat source. A safe installation requires that adequate.clearance be maintained between the Shields must be spaced out from the combustible hot stove and.its connector and nearby,combustibles. surfaced"(25 mm) on noncombustible spacers, as in . 11 Vermont Castings Defiant Figure 13.. The spacers should not be directly behind the stove or chimney connector. Air must be able to flow between the-wall and the shield. At least 50% of the bottom 1" (25 mm) of the shield must be open; and the shield must be open at 1" (25mm) the top. Metal screening across the top will keep small stray objects from being trapped behind the shield. (Fig. 13) The shield must be a minimum of 48, (1220 mm) tall, and must extend at least 20'/2" (520mm) higher than the top of the stove, whichever is higher.The shield behind the chimney connector must be 30" (760 mm) - 1/4"(6mm) wide, centered behind the pipe;for installations that ST501 use an approved prefabricated chimney to pass Fig. 14 A custom-formed mantel shield. through the ceiling, the shield behind the,chimney top plate. With a ventilated shield, this clearance may connector most stop 1" (25 mm) below the ceiling. be reduced safely to 23" (584mm). Air Flow Unprotected top trim (B) protruding 9" (230rnm),or less from the face of the fireplace must be a minimum of Screen 39" (991 mm) from the stove's top surface. With a . ventilated trim shield, this clearance may be reduced Wall shield = f -:, safely to 23" (584mm). Stud wall -Unprotected side trim (C) that protrudes 2" (50mm) or Framing 0'CJless from the face of.a fireplace must have a minimum clearance of 14" (356mm), measured from the stove's Noncombus- top side edge. With a�ventilated trim shield,.the tible Spacers Shield clearance may and Fasteners y be reduced safely to 6" (152mm). If the Metal Spacer trim extends more than 2",(50mm),,it is subject to the Drywall requirements for wall clearance. The charts and sample installations that follow list all the clearances'required for the various installation configurations of the Defiant. Air Flow ST248 Fig. 13 Approved wall shield construction. Fireplace Shield.. A fireplace installation requires special clearance A 8 between the side of the stove and the right and left j + walls, between,.the side of the stove and the decorative side trim on the fireplace face, and between. the top of the stove and the mantel. c I c _ Noncombustible shields installed 1'` (25mm) away form p o o the combustible surface on noncombustible spacers, called ventilated shields;,may be used to reduce clearances. To-protect a mantel from the heat of a stove in a ST253b fireplace installation, use a custom=made ventilated Fireplace and Mantel.Trim Clearances mantel shield that is at least 48" (1220mm).long;that is Unprotected Protected centered over the stove. (Fig. 14) Ventilated shields for A. Mantel ;39"(991 mm) 23''(584mm) side.trim must extend the full length of.the trim. B.Top Trim 39"(991 mm) 23"(584mm) An unprotected mantel ("A", Fig..15) cannot be more C. Side Trim 14"(356mm) 6"(152mm) than 9"-(230mm) deep and must have a minimum Fig. 15 Maintain''clearances to combustible components of clearance of 39" (991 mm), measured from the stove's . the mantelpiece. 72 Vennont Castings Defiant Defiant Clearance Chart for use with either a 6"or 8" chimney connection Stove Clearance Unprotected Surfaces Protected Surfaces Stove . Stove Stove Installed Stove ove Installed Parallel to Wall Parallel to Wall �n Corner Corner Side Rear Corners Side Rear Corners No stove (A) 24" . (B) 33" (C)23" (D) 14" (E)28" (F) 18" heat shields (610mm) (840mm) (585mm) -(355mm) (710mm) (460mm) Stove,top exit with rear (G)24" (H)21 (I) 17" (J) 14" (K) 17" (L) 12" heat shield, no connector, +.(610mm) (533mm) (430mm) (355mm) (430mm) (305mm) heat shields ---------- -----------Stove, ------ top exit with rear heat shield, and heat (M)24' (N) 17 (0) 17 (P) 14 (Q) 17' (R) 12 shields,on connector (610mm) (430mm) (430mm) (355mm) (430mm) (305mm) Stove;.top exit with rear (S) 24" (T) 17" (U) 17" (V) 14". (W)-15" (X) 12" heat shield,and double-wall chimney connector` (610mm) (430mm) (430mm) (355mmm) (380mm) (305mm) ;Stove, rear exit with rear (Y) 24" (Z) 21" N/A (AA) 14" (BB) 17" N/A heat shield only (610mm) (533mm). (355mm) (430mm) Chimney Connector,Clearance -Unprotected Vertical Surfaces Protected Vertical Surfaces Single-wall connector 30" (760 mm) 25" (635 mm) Single-wall connector; rear heat shield on 18'.' (460 mm) 14" (355 mm) stove.only- Single-wall connector with shields, and rear.-heat- 14" (355 mm) 14" (355 mm) shield on stove 'Double-wall chimney, 14" (355 mm) 12" (305 mm) connector _ Single-wall connector Unprotected or Protected Ceiling Surfaces T 24" (610mm) Clearance to Combustibles in Front of Stove All Installations 48" (1220.mm) Using a listed double wall oval to round connector. 13 Vermont Castings Defiant beflan't Clearance Diatirams for use with either a 6"or 8"chimney connection Unprotected Surfaces Protected Surfaces Stove Installed Stove in Corner Stove Installed Parallel Stove in Corner Parallel to Wall to Wall Top Exit Installations, no heat shields 1. B C E F I Al -� �- — .F(Ic 7_�_ 4 OO � C � C� F Top Exit Installations, heat shield on stove, no shields on single-wall connector K L r 7 —.G, Top Exit Installations, heat shield on stove, heat shields on single-wall connector lw NFO. O ® R I P % R OO Top Exit Installations, heat shield'on stove, double-wall chimney connector �, l� !, 1. T W X FF � ; IU ' VI'- d X Rear,Exit Installations, rear heat shields . !. j, Z BB N/A N/A --Y I<_ -AA ST486A 14 Vennont Castings Defiant 48" 48' I._(1220mm)` _(1220mrn) __II 48" 48" -I ( (1220m ) �(1220mm) 48 w, te> (1220nrm) , .? 1�t�+`f. Y Z�.h��. q 41: 48' 1i. T+j y 48� t .t e 1P �. (1220n"n) (1220 rii)+ a { 4e'4 ; 1220mm) CT497 ST499 Fig. 16 Parallel installation,vertical chimney connector,two Fig. 18 Corner installation, vertical chimney connector, two wall shields. Reduced clearances for'both rear and side walls. wall shields. Reduced side clearances.Wall shield MUST Wall shields may meet at corner if desired. Shielding for meet at corner. connector is centered behind connector. Stove Heat Shields The Vermont Castings Defiant Rear Heat Shield, shown below, is one way to reduce the clearance to the rear wall. The rear heat shield can be installed in 48" any setting. However, since the chimney connector (1220,,un also radiates heat toward the wall, you must use a (, chimney connector shield whenever you use the rear heat shield. Clearance reductions with the rear heat shield 4B. •;:, apply only to the wall to the rear in parallel installations. (1220mm .>'f�n' 481220mm) Neither the side clearance requirement nor the clear- ance requirement in corner installations maybe re- i duced. ST498 Flue Collar Heat Shield Fig. 17 Parallel installation with rear wall pass-through,two d Rear Heat . wall shields. Reduced clearances to both rear and side walls. \ Shield Wall shields may meet at corner if desired. Wall pass-through must comply with codes. Refer to"Special Installations." 0. ° Spacers a , Truss Head , Phillips Screws KT287 Fig.19 Defiant rear heat shield with flue collar heat shield for top exit configuration. 15 Vermont'Castings Defiant Distance ftom the Center of • to the Wall The information on this page is helpful in planning stove placement, particularly in those installations with chimneys that pass through the ceiling. However, this is not a clearance chart. Final stove clearances must adhere to,the guidelines in the clearance chart on Page 12. Note that rear dimensions differ for installations with 6"or 8" chimney connectors. Defiant - Shield Unprotected Surfaces Protected Surfaces 1 Parallel Installations Corner Installations Parallel lnstallations Corner Installations Side (A) Rear(B) Corner(C) Side (D) Rear(E) Corner(F) 391/2" (1003mm) 6"chimney: 28" (710mm) 29'/2" (710mm) 6"chimney: 25" (635mm) 27" (685mm) 21" (535mm) 8"chimney. 8"chimney: 28" (710mm) 22" (560mm) beflant With Rear Heat Shield and Shielded Connector, Side (A) Rear(B) Corner(C) Side (D) Rear(E) Corner(F) 39'/2" (1003mm) 6"chimney: 28" (710mm) 291/2" (710mm) 6"chimney: 25" (635mm) 17" (685mm) 17" (535mm) 8"chimney: 8"chimney: 18" (710mm) 18" (560mm) Defiant With Rear Heat Shield and Double-wall Connector: Side (A) Rear(B) Corner(C) Side (D) Rear(E) Corner(F) 39'/2" (1003mm) 6"chimney: 28" (710mm) 29'/2" (710mm) 6"chimney: 25" (635mm) 17" (685mm) 15" (535mm) 8"chimney: 8"chimney: 18" (710mm) 16 (560mm) A -�'�-- B p ' i-D F I -- '- ' y- " This distance, from the center of the flue collar to the front edge of the hearth, is the same for all installations on this page: 34" (865mm) in the United States and 36" (914mm) in Canada. 16 Vermont Castings Defiant Assembly Set Up Your Stove Storing the Handle Cast iron, stoves are heavy, and it will take two to four Use'the removable handle to open or close the doors. people to move your Defiant into position. After using it, remove the handle so it will not get hot. Wipe the-protective coating of oil from the griddle with Store the handle in the handle holder.installed behind a clean dry rag or a paper towel. 'the right front leg. (Fig. 22) Install the'handle on the griddle. Slip the bolt through a washer, a nylon bushing, then through the handleXI and.the other bushing, then through the steel spacer., ILJI and into the griddle tab. (Fig. 20)Tighten securely. ®" d Bottorri Heat Shield 'Spacer Door Handle Holder Bushings Leg Bolt and Washer ST564 Ate—Knob, Washer Fig.22, Handle holder and heat shield positions. ��—Bolt Install - Optional B• • - • ST536 NOTE:'The Bottom Heat Shield is required in most Fig.20 Attach the griddle handle. installations. Refer to Floor Protection, Page 10, for further details. Install • - Legs 1. -Remove the four 10-24 x 1/2" hex head bolts from Remove and discard the four large slot-head screws the corners of the ash drop on the stove bottom. from the stove bottom. Install the stove legs�(Fig. 21) 2. Screw the four 1'/4" spacers into the holes from using the hex head bolts.from the parts bag. Use 3/B" which you removed th.e.bolts, finger-tight. washers'with all.•four'legs; the door handle holder 3. Align the bottom heat shield against the spacers installs on the right front leg. Position-the holder so the with the stepped side toward the rear of the stove. hole to accept the..handle hub faces'out from the right 4. Secure the shield with the four hex head bolts side of the stove:Tighten the bolts firmly. removed from the stove bottom previously.Tighten securely. (Fig. 23) CAUTION: Overtightening can strip,tapped threads. Leg Bolt and Washer O ' Spacers �,"_�_'•� . Leg Leveller ST466a a ST537 Fig. 21 Attach the.stove legs with leg :yellers.' Fig.23 Attach the optional bottom heat shield. le J 7 i Vennont Castings Defiant � . MR � . . - 1. Remove the two Phillips pan head screws from the ash door. 2. Insert the screws through the ash door heat shield (from the painted side), place the 5/16" spacers ``�� over the screws, and carefully thread them back into the original holes. (Fig. 24) The curved lip should be upward, under the-ashlip of the stove., ` 3. Tighten securely. D ST540 'Fig.25 Attach the thermostat handle. Spacers ST538 ST540 Fig.24 Install the ashdoor heat shield. Fig.26 Assemble the front door handle. Adjust the Leg Levellers Lift the stove slightly so there is no weight on the leg / ,, while making the adjustment. tion ileverse the Flue Collar (If Necessary) The Defiant Controls Reverse the flue collar by removing the;two screws Two controls regulate the performance of the Defiant: that attach it to the back of-the stove. Be sure the. a primary'air control supplies oxygen for the fire, and gasket around the flue.collar opening"is in position, a damper directs air flow within the stove to activate when you screw the collar back onto the stove. and deactivate the catalytic combustor. (Fig. 27) Attach the Damper Hand - Symbols cast into the stove are reminders of the correct directions for using the controls. 'Left' and Use the 1/4" -20 x 3 screw to attach the damper 'right' in these directions mean as you face the stove. handle to the damper stub on the left side. Refer to the :chart on Page 35 for hardware sizes.. . jlgDamper Griddle Handle - . • _ Handle Door Handle The primary air thermostat haridle'is the smaller of the two black handles. Secure'the handle to the stub on Air Control the right side of the stove with an '8-32 x 2" slot head �/ Lever, machine screw. (Fig; 25) Andiron • Door Handle, Holder The ceramic removable insert handle opens and. U (Behind closes-the front doors. Remove after each use, and Leg) store it in the handle holder behind the right front leg. Assemble the handle by passing the 33/8" screw through the ceramic shaft and into the bright metal Ash Door Handle nub. (Fig. 26) Tighten carefully until snug. Sr541 Fig.27 The Defiant's controls are conveniently located and :easy to operate. Vermont Castings Defiant • _ Regulates The damper is closed when the handle points for- A SinAir Control _ ward. Smoke travel's through the catalytic combustion Heat Output and Burn Tim system where it can be further burned, before passing The primary air control lever, on the right side of the, up the chimney. (Fig. 29) stove;controls the amount of incoming air for starting, The damper.is either fully open or fully closed. maintaining, and reviving a fire. There are no'intermediate positions. When closing More air entering the stove makes the fire burn hotter the damper, be sure to pull firmly enough to snap and faster, while less air prolongs the burn at a lower the handle into the locked position. heat output level. (Fig. 281) Damper Positions For the greatest air supply and maximum"heat output (but the shortest burn time), move the lever toward the • front of the stove. For a fire that will last longer with I I'I'I NI lil:I'IANI less heat, move the lever'toward'the rear.of the stove. N> O . U • The Defiant's.air control system includes an.automatic thermostat to.ensure an even.heat output at whatever manual setting you select. The'thermostat senses the o.(�en. Closed heating and cooling of the stove surface and adjusts ST543: (Updraft Mode) (Catalytic Mode) the air valve accordingly. Fig.29 The Defiant's damper operating positions.. Air Control Positions Two Ways to Add Fuel The Defiant's griddle lifts for convenient top-loading of DEFIANT logs, and,i&the easiest way to add fuel. (Fig. 30) Low Heat Range o • Medium Heat DEFIANT « Range -- o • ZQ - -_ ST521 Fig.30 Top loading is the best way to add fuel during regular — use. Front loading is useful for kindling a fire. However, the front doors open as well for adding an High Heat DEFIANT occasional log to a fire. If the stove is equipped with 8" Range 41 (200 mm) stove pipe, the front doors may be opened (or even removed) and the optional Defiant spark, screen placed in the opening for open-fire viewing. sT542. The Defiant.is not approved for operation with the front doors open:if equipped with a 6"(150 mm) Fig.28 The handle also,may be positioned anywhere chimney connector. between the two extremes for different heat levels. To open the front doors, insert the handle into the door Damper Di - latch stub.and turn it to the left and up. (Fig. 31) StoveWithin the To close.them, always close the left door first. Turn the The damper handle on the left side of the stove handle in the right door to the left and up (to the open operates the damper to,direct`air flow within the-stove. position) and close it. Finally, push,on the door as you turn the handle to the right and down. The doors will The damper is open when the handle points to the draw in slightly, and the handle should offer some rear,enabling smoke to pass directly into the`chimney. resistance as you turn it to the closed position. The damper must be open when starting.or reviving a fire, and whenever the griddle or doors are opened. '19 Vennont Castings Defiant Burn Only High-Quality . . . Clockwise to Open The Defiant.is designed to burn natural wood only; do not burn fuels other than that for which it was Zq de- signed'. ockwise "You'll enjoy,the best results when,burning wood that to close has been adequately air-dried. The.wood should be 22-24" (559-610 mm) in length.Avoid burning"green" wood that has not been properly seasoned. Do not burn construction materials; they often contain ST544 chemicals and metals that can damage the catalytic combustor"or pollute the air. Do not burn ocean drift- . Fig.31 To open the front doors,'turn the handle clockwise. wood; when it burns, the salt it absorbs will attack the To reduce the risk of.breaking the glass, avoid striking cast iron. the glass or slamming the doors. The best hardwood fuels include oak,;maple, beech, When you're not using the door handle, store it in the ash, and hickory that has been.split; stacked, and air- holder behind the'left front leg of the stove. Be careful `dried outside under cover for at least one year. to not drop the handle, since it is breakable. If hardwood is not available, you ban burn softwoods WARNING: Fireplace stoves equipped with doors that include tamarack,yelloW'pine, white pine, Eastern should be operated only with doors fully open or red cedar, fir, and,redwood. These should also be doors fully closed. If doors are left,partly open, gas properly dried. and flame may be drawn out of the fireplace.stove opening, creating risks from both fire and smoke. Store Wood under cover to keep it dry. The longer it is The Defiant may be used as a fireplace with the stored;the better heating and fire-viewing performance you will enjoy. Even for short-term storage, however, front doors open or. removed, BUT only when it'is keep Wood a safe.distance.from the heater and keep it equipped with 8 (200mm)stove pipe and only out of the areas around the heater used for refueling when the optional spark screen is placed-correctly in'the opening to protectagainsi the possibility of and ash removal. sparks and embers leaving the stove: A Surface Thermometer is a Valuable Use only the Defiant spark screen, Item #1907,with Guide to Operation your Defiant. Defiant spark screens are available from your An optional surface thermometer tells you when to adjust the air control, and when"to refuel. (Fig. 32) Vermont Castings Dealer. ClearInfra-Red Reflective Glass Panels for - The outer surfaces of the ceramic glass panels have, K. sTszs an infrared-reflective coating which keeps the inner I� surfaces warm. This design, along.with a pre=heated Fig.32 Take temperature readings with a thermometer 'airwash,' makes clear fire viewing possible at most located in the middle of the griddle. firing levels., For example, when the thermometer registers at least Ahdirohs - Protect 450°F. (2300C).after start-up you know that the stove is Your stove has andirons to keep logs away from,the hot enough to begin catalytic combustion and that it, may be time to close the,damper.. Note glass panels: The andirons are essential to maintain that the stove clear fireviewing, and.should be left permanently in will warm,up_much sooner than the,chimney, though;.a warm chimney is the key to easy, effective stove place. Since the andirons.may slightly hinder refueling through the front doors, most stove owners Will prefer operation. Please review the draft management the convenience of top loading through the griddle. Do information on Page 26 to see how the size, type, and location of your chimney will affect your stove opera- " not place fuel between the andirons and the doors. tion. When thermometer readings dropbelow35WF. (1751C) it's time to adjust the air control for a higher burn rate or to reload the stove. A temperature reading over 750°F. (385°C) is'a sign to cut back on the air supply to slow the burn rate. 20 Ver►nont Castings -Defiant . Use the following temperature ranges as a guide: Most installations do not require a large.amount of - J combustion air, especially if adequate draft is available. • Readings in the 3500-5000F..(1750-2600C) range Do not for any reason attempt to increase the firing indicate low to medium heat output. of your heater by altering the ait;control adjust- , •. 500-600°F. (260°-3150C) readings indicate medium ment range outlined in these directions. ,heat output. Use the following air control settings as a starting point • Readings of�600°750°F. (315-385°C) indicate high to help determine the best settings for your installation. heat output. Operating your Defiant continuously at Each is described,as a fraction of the total distance the griddle temperatures of 7500 F:,(385°C) or higher lever may be moved from right to left. may damage the cast iron.or enamel finish. Defiant Control _ • ControlUse the Air (Refer to Figure 27, Page 19), that Work Best for • Burn Rate Primary Air Control No single air control setting will fit every situation. Low From far right to 1/3 the distance Each installation will'differ depending on the quality of to left the fuel, the amount of,heat desired, and how long you Medium From 1/3 to 2/3 the distance wish the fire to burn; outdoor air temperature and to left pressure,also affect,draft. High From 2/3 the distance The control setting also depends on your'particular to'left, to farleft installation's "draft,"or the force that moves air-from the stove up through the chimney. Draft is affected byHigh-Efficiency . . . Burning such things as the length, type, and location of the Catalytic Combustionwith chimney, local geography, nearby obstructions, and other factors. See Page 26 for details on how the A Defiant leaves the factory with the combustor installation affects performance.- installed. Too much draft may cause excessive temperatures in In the United States, it is against the law to operate this the Defiant, and,could even damage the combustor. wood'heater in a:manner inconsistent with operating On the other hand, too little draft can cause instructions in this manual, or if the catalytic'combustor backpuffing into the room and/or the"plugging"of the is deactivated or removed.The components of the chimney or combustor. catalytic combustion system in your Defiant work How do you know if your draft is excessively high or together to produce optimum conditions for secondary low? Symptoms of too much draft include an uncon- combustion.. trollable burn or a glowing-red stove.part. Signs of When the damper is closed, smoke travels through the weak`draft are smoke leaking into the room through the catalytic element, which,causes ignition of smoke'at stove or chimney connector joints, low heat, and dirty temperatures of 500-6001 F (260-3151C), half the glass. temperature normally required for unaided;secondary In some.newer homes thatare well-insulated and combustion. weather'4ight,.poor draft may result from insufficient air The catalytic elementis a ceramic."honeycomb"'coated in the house: In such instances, an open window near with the catalytic'material.The element is located in the stove on the windward,side of the house will the secondary combustion chamber, molded from a provide the fresh air needed. special high-temperature insulating refractory material. ' Another option for getting more,combustion air to the The chamber provides the correct environment neces- stove is to duct air directly from the outside to the, sary'for secondary combustion of.the fuel (smoke). stove. ,In some areas provisions for outside combus- Closing the damper exposes the smoke to the combus- tion air are required in all new construction. tor. If the combustor is at least600°F (3150C), it will With an optional outside air adapter, No. 1904,.your begin to burn the smoke. Defiant will accept a duct to deliver outside air for Closing the stove damper may also.reduce the draft, combustion: so to avoid putting out the fire or deactivating the When first using the,stove, keep track of the air control combustor, close the damper only when.a fire is well- settings. You will quickly find that'a specific setting will established and the chimney is thoroughly warmed. give you a fixed amount of heat. It may take a week or When starting a fire, wait until the fire is well estab- two to determine the amount of heat and the length of lished and there is an ember tied.of at least 3-4 inches burn you should expect-from varioussettings. before closing the damper.' 21 Vermont Castings Defiant Never kindle a fire With colored paper or.paper that has Do not use chemicals or fluids to start the fire. Do colored ink or a glossy surface, and never burn treated not burn garbage or flammable fluids such as wood, garbage, solvents, or trash. All of these may gasoline, naphtha, or engine oil. poison the catalyst and prevent it from operating 1. Open the stove damper, and open the primary air properly. Never burn cardboard or loose paper except control fully.. for kindling purposes. Never.burn coal.; doing so can produce soot or large flakes of char or fly ash that can 2. Place several sheets of crumpled newspaper in the the combustor and cause smoke to spill into the stove. Do NOT use glossy advertisements or colored room. Coal smoke also can poison the catalyst so that paper, as they can poison the catalyst. Place on the .it won't operate properly paper six or eight pieces of dry kindling split to a finger- width size, and on the kindling lay two or three larger In general, the fire must be sufficiently well-established sticks of split dry wood approximately 1-2" (25-50 mm) to ensure that catalytic activity is initiated.When first 'in diameter. (Fig. 33) starting a fire, a medium- to high- firing rate must be maintained until the stove, catalyst, and fuel are all stabilized at the proper operating temperatures, and the chimney is warmed. —___— Even though it is possible for the fire to get quite hot within a few minutes after a fire is started, the combus- tor may stop working or the fire may go out if the fire dies down immediately as a result of the damper being closed. Once the combustor starts working, heat generated by burning the smoke will keep it working. - To determine whether the combustor is operating, srzs3 observe the amount of smoke leaving the chimney when the damper is activated and when it is not.. This Fig.33 Start the fire with newspaper and dry kindling procedure is described on Page 31. Also, never use gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or Avoid using a full load of very dry wood in the firebox: "freshen up" a fire. Keep all such liquids well away, This may result in continuous very high temperatures from the Defiant while it is in use. in the secondary cornbustion area and damage the combustor. Wood which has been split, and stored 3. Light the newspaper and close the door. Gradually under cover for more than 18 months may be consid- build up the fire by adding a few 3-5" (80-120 mm) ered very dry. 'If you must burn extra-dry wood, mix it diameter splits. If this is one of the first few"break- with greener wood for a longer fire and less stress on in" fires, let the fire burn brightly, and then let it die the combustor.Also, do not use a full load of dry slab out. wood or scrap wood. For long burns, use a mix of dry During the break-in fires, do not let the stove get hotter and moderately dry wood. than 500°F. (260°C) as measured on an optional stove- top thermometer. Adjust the air control lever as neces- Cohditionihg Your Stovesary to control the fire. Cast iron is extremely strong, but it can be broken with Some odor from the stove's hot metal, the paint, and a sharp blow from a hammer or from the thermal shock the cement is normal for the first few fires. of rapid and extreme temperature change. NOTE: Some chimneys must be "primed," or warmed The cast plates expand and contract with changes in up; before they will draw sufficiently to start a fire. To temperature. When you first begin using your Defiant, correct this situation, roll up a couple pieces of newspa- minimize thermal stress by letting the plates adjust per, place them on top of the kindling and toward the gradually during three or four initial break-in fires back of the stove, light them, and close the doors. This following Steps 1-3 below. will encourage the smoke to rise rapidly, making it easier to establish a good draft. • • • Once the draft is established, open the front door'and Burn only solid wood in the Defiant, and burn it directly light the rest of the fuel from the bottom. Do not light on the grate. Do not elevate the fuel. Do not burn coal the main bed of fuel until the chimney begins drawing, or other fuels. and repeat the procedure as often as necessary if the The damper must be open when starting a fire or when initial attempt is unsuccessful. refueling. 22 Vermont Castings Defiant 4. If your Defiant has been broken-in previously Do not break the charcoal into very small pieces or using Steps 1-3, continue to build the fire gradually. pound or compress the charcoal bed. Add larger wood with a diameter of 3-4" (75-100 mm). It is important that air can circulate through the char- Continue adding split logs of this size to the briskly- coal bed during the burn. Larger pieces of charcoal burning fire until there is a glowing ember bed at least allow more air to circulate under the wood, resulting in 3" (75 mm) deep. (Fig. 34)A good ember bed is neces- sary for proper functioning of the catalytic system and may take an hour or more to establish. For best results when refueling, wear long-cuffed stove gloves to protect your hands and forearms;add fuel r Close the damper when the griddle temperature while the stove still has plenty of glowing embers to re- reaches 450°F (230°C). kindle the fire, and include some smaller pieces of 6. Adjust the air control for your desired heat output. wood in the new fuel load to help the stove regain its operating temperature quickly. Use this sequence as a guide to successful refueling: 1. Open the damper. 2: De-ash the stove as described above. Open the ashdoor and check the level of ash in the ash pan. Empty the pan if necessary and replace it in the stove. Close the ash door. 3. Open the griddle, load the wood (smaller pieces first), and close the griddle. 4. Close the damper. ,. 5. When the surface temperature reaches 450° F. ST264 (2300C), adjust the air control for the amount of Fig.34 Add larger pieces of wood as the fire begins to burn heat you desire. well. NOTE: If the remaining charcoal bed is relatively thick NOTE: Stove installations vary widely, and the operat- and if your fuel is well seasoned, it is possible to add ing guidance given here is only a starting point . The fresh fuel (smaller pieces first), close the door and draft management information on Page 26 will explain damper, and reset the primary air thermostat for the in detail how the features of your installation may help desired heat output. or hinder good draft, and how you may need to vary WARNING: Osperate your Defiant only with the your firing technique if your installation doesn't encour- doors either fully open or fully closed. age a good draft. CAUTION: The Defiant will be hot while in operation. Keep children, clothing and furniture away. Contact may cause skin burns. DO NOT OVERFIRE THIS HEATER. Overfiring may cause a house fire, or can result in permanent damage to the stove and to the catalytic combustor. If any part f� of the Defiant other than the baffle and/or catalytic combustor glows, you are overfiring. The throat is made of a special cast iron which can withstand higher temperatures'than most other parts of your stove. It protects the catalytic element from direct ST264a flame impingement, which can shorten the catalyst's life. Since the throat is in the direct path of flame Fig.35 Add full size logs after the ember bed is 3"(75mm) between the firebox and the catalyst, it reaches higher deep. temperatures than other firebox parts, and it may glow Refuel . - Are Still Hot at times. If it does glow, you will see this directly through the front doors.The glow is normal and does When reloading, best results will be achieved if you not indicate a problem. first de-ash the stove by stirring the fuel bed to allow ash to fall through the grate into the ash pan. At times you may see a glow from the catalyst shining through the ports of the throat. This is also normal and does not indicate a problem. The catalytic element, 23 } Verniont Castings Defiant, located below and.behind the'-throat;can glow at high temperatures.This is also normal. However, the element can be active and operate properly without U glowing. The lack of a glow does not indicate that the ' that the catalyst is most catalyst isn t working. Note t y ��. likely to glow at its higher temperatures, which it reaches when the firebox is in its lower range-the ° catalyst is an afterburner, and the more waste fuel there is in the smoke, the hotter the catalyst gets. We strongly advise,the use of a stove-top thermometer as a guide to stove performance. Normal operating temperatures are between 450°F (22066) and 700OF (370°C). Lower temperatures can indicate incomplete combustion and weak draft; higher temperatures can sTSss shorten the life of the castings. Fig.37 Be sure the cover is securely attached before • •sal removing the ash pan. Ash DisRoutine ash removal'is important for ease of mainte- •. Remove the ash pan, making sure to keep it level. nance, and is important for the stove's durability. • To keep the cover from sliding off and to keep ash Remove ash before it reaches the top of the ash pan. from falling on the floor, do not tilt the ash pan Check.the level at least once a day. Every few days, forward. clear any ash from the outer edges of the firebox. Most If the stove is in operation, close the.ash door while of the ash will fall through the grate..Slice or stir the. disposing.of the ash. You may need to lift the latch ash witha shovel or poker so that it falls through the end of the door slightly to align the latch with the grate slots. mating part on the stove bottom. IMPORTANT: Check the level of ash in the ash pan e Properly dispose of the ash in a metal container with before reloading the stove. If the ash level is close to a tight-fitting lid. Store the container outdoors away the top edge of the pan, empty the pan according to from all combustible material. this procedure: Return the ash pan to its original position in the • Open the damper stove, and close and latch the ash door. (rig. 37) •; ,Open the griddle or front.doors, and use a shovel or • '�Do not operate the stove with the ash door open. poker to stir excess'ash through the ash slots in the This will result in over-firing, and could cause grate down into the ash pan. damage to the stove, void the warranty, or even • Close the griddle or doors, and unlatch the,ash lead toA house fire. door. (Fig. 36) It will pivot, swinging the ash pan out Empty the.ash pan regularly, typically every one to of the stove. three days.The frequency will vary depending on how you operate your Defiant: ash will accumulate faster at Slide the cover onto the pan, making sure it is securely closed. (Fig. 37) higher heat outputs. Remove ash frequently and place it outdoors in a metal container..with a tight-fitting lid. Place the closed _ container of ash on a noncombustible floor or on the ground, well.away from all combustible,materials, r-----� pending final disposal. If the ash is disposed of by burial in soil or otherwise-locally dispersed, it should be kept in the closed container until all cinders have thoroughly cooled. Open 'You can use wood ash as a garden fertilizer. CAUTION: Never use your household or shop Close vacuum cleaner to remove ash from the stove; always o remove and dispose of the ash properly. ST546 Fig.36 Turn the ashdoor handle clockwise to open and counterclockwise to close. 24 iVermont Castings Defiant Draft Management A stove is part of a system, which includes the chim- ChimneY Height ney, the operator,'the fuel;and the home. The other parts of the system Iwill affect how well the stove The common wisdom tells us that,a taller flue draws works. When there is a good-match between.all the 'better than.a short one. This isn't necessarily so. If a parts, the.system works-well. _ chimney istall enough to meet the safety requirements Wood stove or insert operation depends on natural of the 2/3/10 foot rule, then adding more height isn't i the right answer to.a draft:problem:In fact it.could (unforced) draft. Natural draft occurs when the smoke make the problem worse, by adding more mass to the is hotter(and therefore lighter) than the outdoor air at chimney system, which the smoke must warm up, at i the top of the chimney.The bigger the temperature the far end from the heat source (the stove). Don't difference, the stronger the,draft.As the smoke rises from the chimney it provides suction or'draw'that pulls make a chimney taller unless you must to meet the air into the stove for combustion.A slow, lazy fire with safety rules, or unless there s some nearby feature the stoves air inlets fully open indicates a weak draft. causing a downdraft. Even then, there are downdraft- A brisk fire; supported only by air entering the stove preventing chimney caps available, which are probably through.the normal inlets, indicates a good draft. The the smarter choice. stove's air inlets are passive; they regulate.how,much Flue Sizing air can enter the stove, but they'don't move air into it,. The inside size of a'chimney for an 'airtight' stove Depending on the features of your installation - steel or should match the size of the stove's flue outlet.When masonry chimney;.inside or outside the house,, a chimney serves an airtight, more is not better; in fact, matched to-the stove's outlet or oversized your it can be a disadvantage. Hot gases lose heat through system may warm up quickly, or it may take'a while to expansion; if we vent a stove with a six-inch flue'collar warm up and operate well. With an'airtight' stove, one (?B square.inch area) into a 10 x 10" flue, the gases which restricts the amount of air getting into the expand to over three times their original size. This firebox,the Is must keep the smoke warm all cools the gases, which weakens draft strength. If an the way,to the outdoors in order for the stove to.work oversized flue is'also outside the house, the heat it well. Some chimneys do this better than others. Here's absorbs gets transferred to the outdoor air and the flue a_list of features and their effects. usually stays cool. ChimneyMasonry It's common for a masonry flue, especially one serving.: a fireplace, to-be oversized for the stove. It can take Masonry is a traditional material for chimneys, but it quite a,while to warm up such a flue, and the results, can perform poorly when it serves an 'airtight'stove. can be disappointing..,The best solution to an oversized . Masonry is a very effective 'heat sink' - it absorbs a lot flue is an insulated steel chimney liner,the same ,of heat.,It can cool the smoke enough,to diminish draft. diameter a's the stove or insert's flue outlet; the liner The bigger the chimney; the Jonger it takes to warm keeps the smoke warm, and the result is a stronger, up. It's often very difficult'to warm up an outdoor. draft:An uninsulated liner is a second choice - the liner masonry chimney, especially an oversized one, and keeps the,smoke restricted to its original size, but the keep it warm enough to maintain an adequate.draft. smoke still must warm up the:air around the liner. This Steel Chi - makes the warm-up process take longer. Most factory-made steel chimneys have a layer of Pipe out insulation:around the inner flue.,This insulation keeps Every turn the smoke must take as it travels to the the smoke warm. The insulation is less dense than chimney top will slow it down. The ideal pipe and masonry, so a steel chimney warms up,more quickly than a'masonry chimney. Steel doesn't have the good chimney layout is,straight up from the stove, to a looks of masonry, but it performs much better. completely straight chimney. If you're starting from . scratch, use this layout if possible:If the stovepipe Indoor/Outdoor must elbow to enter a chimney, locate the thimble about midway between the stove top and the ceiling. Because the chimney must keep the smoke-warm;it's best to locate it inside the house. This uses the house This achieves several goals: it.lets the smoke speed up before it must turn, it leaves some pipe in the room for as insulation for the flue and allows some heat release heat transfer, and it gives you long-term flexibility for into the home. An indoor chimney won't lose its heat to installing a different stove without relocating the the outdoors, so it takes less heat from the stove to, thimble. heat it up and keep it warm. 25 i 2(i Vermont Castings Defiant There should be no more than eight feet of single-wall can:lose a third or more of its weight as it dries. Also stove pipe between the stove and a chimney; longer look at the'ends of a log; as it dries it shrinks and,often runs.can cool the smoke enough to cause draft and cracks. The more weathered.and cracked a piece is; creosote problems. With prefabricated chimney;bring it the drier:it is., - down to six to eight feet.from the stove. With a ma- Dry wood burns readily with a good chimney draft. b6t sonry ,chimney,'arrange the pipe layout to elbow into, with.modern stoves, especially catalytic ones, the the-chimney within eight feet of the stove. wood can be too dry. While;extra-dry wood has little creosote in.it, the remainder can 'gas out' from the Sihgle Venting wood quickly and densely enough to overload the Each 'airtight' stove requires its.own flue. If an airtight catalytic burner. If you hear a rumbling or roaring stove is vented to a flue that also serves an open noise, like a propane torch, from the stove, that is a fireplace, or a leakier stove,.it's easier for the chimney sign that the catalyst is seriously,overfiring.The draft to pull air in through'those channels than it is to catalyst is,a platinum'film on a ceramic base; the metal pull.air through the airtight, and performance suffers. can get to higher temperatures than the ceramic can Imagine a vacuum cleaner with a hole in the hose to take, and overfiring the:catalyst can break it. Dry wood see the effect here. In some cases the other appliance can also burn out faster than you want. If your dry can even cause a negative draft.through the airtight, wood burns out too quickly or overloads the catalyst and result in a dangerous draft reversal. you can mix in greener wood to slow the fire down. Creosote is a by-product of slow wood-burning. It's an Back-puffing results when the fire produces volatile organic tar that can condense in the flue if it's dense in gases faster than.the chimney draft pulls them out of the smoke, and slow-moving, and,cools off to less than the.firebox.The-gases back up in the firebox till they're 290 degrees F (130"C): Condensed'creosote is vola- dense enough'and hot'enough.to ignite. If your stove tile, and can generate,chimney fires if it gets hot back-puffs, you should open up the'damper to let the enough. All the features that affect chimney draft also smoke rise to the flue''more quickly, let more air into affect creosote condensation-'so use whatever the firebox, and avoid big loads of firewood. You combination of installation features and operational :should always see lively, dancing flames in the firebox; steps will encourage:good draft and minimize creosote a lazy, smoky fire.is inefficient and can contribute to production. creosote buildup in the chimney. Because letting the smoke cool off and slow down is one-of the keys to.creosote production,.it makes sense to line a chimney'to.match the stove's outlet size, for An easy way to test your chimney draft is to close the safety reasons,as well as performance. Canadian law stove's.damper,wait a few minutes to let the airflow requires a matching liner to serve any stove or.insert stabilize, then see whether you can vary the strength, vented through a fireplace chimney; in the US, the of the fire by swinging the air control open and closed. National Fire Protection Association recommends one if Results are not always instant; you may need to wait.a the flue is more.thanthree times bigger(in.square area) few minutes for,a change in the air control setting to than the outlet on the stove or insert. Some localities have an effect on the fire. If there's no change, then enforce the NFPA guidelines as part of their building the draft isn't strong enough yet to let you close the codes. damper, and you'll need to open it for a while longer and manage the fire with the air inlet until the draft strengthens. If you keep track of your burning habits Even the best stove installation,will not perform well and relate them to their effects on the stove's opera- with poor fuel. The best fuel is hardwood that has air- : 'tion, you'll'be'rewarded with good performance and a dried 12-18'months. Softwood burns, but not as long safe system. as hardwood. Fairly`green'wood has a lot of moisture in it; it will burn, but some of the heat potential is used to,drive the remaining moisture off the wood. This. reduces the amount of heat that reaches your home and can contribute to a creosote problem. There are moisture meters available for firewood; you can also judge your wood by its appearance and weight. It you get it green, lift a piece and get a sense of its weight; it 26 i Vermont Castings Defiant i Negative Pressure Good draft also depends on a supply of air to the stove; a chimney can't pull in more air than is available to it. Sluggish draft results when a house is tight enough to prevent the ready flow of air to the stove, or I by competition between the stove and other equipment that sends indoor air outside - especially'power-driven equipment like range hoods, clothes dryers, etc. If the chimney draws well with all other equipment turned off (or sealed, in the case of fireplaces and/or other stoves), then you simply need to be careful with timing the use of the other gear. If you need to crack a nearby window or door to enable the chimney to pull well, ithat's a sign that you should install,an outside-air intake to bring combustion air directly to the stove. An outside air adapter will attach to the stove to connect an air duct for outdoor combustion air. Conclusion Wood-burning is an art rather than a science. Once the stove and chimney system are in place, you can only vary your technique, mostly your timing, to achieve good results. If you keep track of your burning habits and relate them to their effects on the stove's opera- tion, you'll be rewarded with good performance and a safe system. 27 I . Vermont Castings Defiant WorkingKeep Yo'ur Stove Looking New and RemoVihg the Glass Its Best1. Remove the right and left door assemblies by, , Let the fire in the stove go out and allow the stove to. raising the door until the lower hinge pin clears its cool completely:before beginning any maintenance hole; then, angle the door bottom slightly outward procedure. and pull down'to release the upper hinge pin. Place the doors face-down.on a padded work surface. Be Care of - Cast lrod Surface especially careful with enamelled-doors. 2. Remove the screws that hold the glass retainer clips An occasional dusting with a dry rag will keep the in place, and remove the clips. painted cast iron of your Defiant looking new. 3. Carefully'lift the broken glass panel from.the door. The stove's paint can be touched up as needed. First_, mask the areas, such as enamelled parts, glass, or IhStalling the Glass handles, around the spot to be painted. Clean the spot Check the gasket around the window; it should be soft with a wire brush. Remove the griddle and set it aside. and resilient so that the glass will seal properly against It is normal for the griddle to darken after use. You can the door. Replace the gasket if,it has hardened or if it clean it with a fine'=bristle wire brush, or steel wool. is compressed. Then, touch up the stove with Vermont Castings' high 1. Center the glass on the gasket. Be sure to place the temperature stove paint.Apply the paint sparingly; two glass so'that the infrared reflective'coating is on the light coats of paint are better than a single'heavy one. exterior side, facing toward the room:' 2. Secure the glass on both doors with the retainer Care of the Porcelain Eriaibel Surface clips. Tighten all,screws. (Fig. 38). Use a dry or slightly damp rag or soft brush to remove 3. Replace the doors on'the stove. spills or stains.'For difficult jobs that require a cleaning 4. Open and close the,doors to check that they fit and agent, use only a kitchen appliance cleaner or polish work properly.Adjust as necessary. recommended for use,on enamel surfaces. . Cleahihg the Glass Most of the carbon deposits on the glass will burn off Door Gasket- Right Door during hot fires. However, the ash residue,that accumulates on the glass surface should be removed regularly to prevent f�� etching.To clean the glassJollow this procedure: Be sure the glass is completely cool. w,..., ,,.__......,. . �, • Clean the,glass with water or,a cleaner'made especially for this purpose. Do not use abrasive Left Door cleaners.,-Use cleaning agents'sparingly and be sure to keep them off the outer surfaces of the stove. Glass Gasket • Rinse the glass thoroughly. Glass Panel • Dry the glass completely. Retainer Clip , keplace WokehImmediately Do not o,perate.your,stove if the glass in the doors is Retainer clip ST547 damaged'.,' If you need to replace the glass; use only the high Fig:38 An exploded view of the glass assembly. temperature ceramic glass supplied by Vermont Castings. Do,not use substitutes. Be sure to specify left or right glass; the panels are'not interchangeable, due to a heat-reflective coating on the side toward the room. 28 Verrnorat Castir7Js Defiant • Check - Operation of the Pressure Primary Air Shutter Adjusting Lock Nut Screw The primary air shutter is at the back of.the ash drop Allen Damper and is visible from the back of the stove:(Fig. 39) The 'wrench shutter must open and close freely when you,move the thermostat lever. If it doesn't, remove''any obstruction: If you,need assistance, consult:your.local Vermont . Castings Authorized.Dealer. ST554 'Do nof change'the adjustment of the cable in an attempt,to gain increased firing. The air shutter,controls Fig.40 Adjust the damper with the Allen wrench.. how much air can enter the stove; but chimney draft is , the force'that pulls air into,the stove. If changing the Tighten the Damper Handle as Needed thermostat,handle position does not lead to changes in , the fire's intensity within four or five minutes, it's A handle on the left side.of the stove controls the probably due to weak chimney draft(in the case of a damper. The handle attaches to.the damper rod with a ' weak fire;you can't increase) or an air leak in the stove set;screw. Periodically check the set screw and tighten (in the case of a fire you can't decrease). as necessary. How to Adjust theDoor Latches MID The'Defiant's doorsshould close securely to prevent accidental opening and to keep air from leaking into the stove.On'adequately adjusted doors, the handles should resist slightly as they are,turned to the closed position and the doors themselves should be.drawn slightly toward the stove. Over time, the gasket around the doors will compress and,the latches may need.adjustment. 'To.adjust the latches,,loosen the small lock nut, rotate the striker screw a half-turn, and re-tighten the small lock nut.'(Fig. 41) Your stove kit includes an Allen wrench for latch adjustments.Hold the striker screw to Primary Air Shutter ST548 keep it from turning as you tighten the lock nut.'Make ' repeated small adjustments until the setting is right. Fig.39 The primary air shutter must move freely. Pawl Adjust the Damper as Needed The tension on the Defiant's,dam damper, to , Small P 1 Locking Nut compensate.for compression of the gasket that seals striker screw the damper to the upper fireback. To adjust the damper: Large Locking 1., Remove the griddle. Loosen the lock nut at the Nut center of the damper. (Fig.,40) i 2. Turn the pressure screw'approxi mate ly one half turn • clockwise with an'Allen wrench provided with your stove. 3. Tighten the lock nut. Prevent the pressure screw Set screw from turning as you tighten'the nut:Re-test the ` damper.. .- handle Stub S r531 Fig:41 Turn the door latch striker screw in or out to tighten of loosen the screw. Vermont Castings Defiant The Catalytic Element Burning"green".(insufficiently seasoned) wood will result in poorer performance than burning properly This wood heater contains a catalytic combustor, which . seasoned fuel. You may have.to run your stove hotter needs periodic inspection and replacement'for proper (more air)to achieve acceptable performance using operation. In the United States it is against the law to green or wet wood. operate this wood heater,in a manner inconsistent with . the operating instructions in this manual, or if the Also, consider any changes in your operating routine. ..catalytic element is deactivated or removed.. Once you have ruled out any other possible causes for Under normal operating conditions., the catalytic a decline in performance, inspect and clean the com- combustor.should remain active for two to six years bustor if necessary. Be sure to protect any surface you (depending on the amount of wood burned). However, use for setting the stove parts aside. it is important to monitor the combustor periodically to Inspecting o ensure that it is functioning properly, as well as.to -determine when it'needs'to be'replaced.A non" 1'. Lift the throat off its support brackets, and-.then functioning combustor will result in a loss of heating remove it from the stove and.place it on a protected efficiency, and an increase in creosote and emissions. surface:(Fig. 42) 2. Use'aJ lash light, and a mirror if necessary, to exam- Inspection and Cleaning ine the combustor. If no fly ash or damage is visible, Inspect the combustor"in place"for fly ash accumulaw. the inspection is complete and you may replace the tion and physical damage three times per year. Clean baffle. If closer examination or cleaning is needed, the combustor'as needed.,Do not remove the combus- go to'the next section. for unless a more detailed inspection is warranted . because of diminished performance as outlined in the next section. Baffle Support Brackets The refractory package that houses the catalytic combustor should be inspected annually for a buildup of fly ash and cleaned if necessary.This may be done 'when you'examine the combustor. When To SUtpect a Combustor Ptoblem The best way to evaluate the performance of your 6 Defiant's combustor is to observe the amount of smoke leaving the chimney—both when the combustor has ''lighted-off'and when it has not. Follow these steps: • With a'fire going and the,.combustor properly activated,�with the damper closed.to route smoke;, Catalytic through it as described in the Operation Section, go Element outside and observe the smoke leaving the chim sTsSe ------ ney. Fig.42 Lift the baffle off its,supports to inspect the catlyst. Then, open the stove damper and once again check , the smoke leaving the chimney. Removing and Cleaning the Combustor You should:'see significantly more smoke'when the 1. Remove the firebricks. Lift off the steel clip and stove damper is open and exhaust''does not pass remove the bricks individually. (Fig. 43) through the combustor: However, be careful not to 2. Tap:the left and right wedges:upward, and remove confuse.smoke with steam from wet wood. Steam the lower fireback by pulling it.forward. You can dissipates in the air quickly;smoke.does not. either let it lie face down on the firebox floor, or If this test indicates a problem, consider ofher.possible remove it from the 'stove, through the front door factors.as well, such as the weather,or a change in the opening. (Fig. 44) quality of your fuel. In warm weather, draft is,weaker than it is in colder winter weather, and fires can burn sluggishly. Small, hot fires are a good solution under these conditions. .10 Vermont Castings Defiant Alignment Notches Left Wedge Right Wedge K r Bric Catalytick Guide d; Element Brick Chip y MEN Catalytic Access ST558 PaneBricks sT556 Fig.45 Remove'and inspect the catalytic element. Fig.43 Remove the bricks and the brick retainer. 5. Inspect the element for damage or degradation. Although small hairline cracks will not affect perfor- mance, the element should be essentially intact. If I the element is broken in pieces or has sections missing, it should be replaced. Call your local Vermont CastingsMajestic Products Company Authorized Dealer for a replacement element. While the catalytic element is removed, check the ® 0 condition of the secondary air probe. Use an inspection ° mirror to locate the probe within the combustion chamber. (Fig. 46)The probe should extend 1" to 1 t/z" into the chamber and show no signs of excessive deterioration, such as warping, corrosion, or short length. A damaged secondary air probe can affect Lower Fireback ST557 catalytic performance. If the probe needs replacement, contact your local dealer. Fig.44 Remove the lower fireback. 3. Carefully remove the catalytic combustor's refractory• f access cover, then remove the combustor.The sr ; refractory material is brittle; handle it carefully. (Fig. ` ;r 45) 4. Check the combustor's honeycomb-like element for —1'-- a buildup of fly ash. If any is evident, take the combustor outside and clean it by blowing air gently through it. Do not push anything through the honey- ; comb; do not use compressed air to clear-the passages. Such abrasion can scrape the thin -� coating of platinum (the catalyst) off the ceramic base, shortening the catalyst's life and reducing its effectiveness. ST559 Fig.46 Use an inspection mirror to check the reflected view of the secondary probe. 31 Vermont Castings Defiant 6. ,If the element is in good condition and clean, re= `Wait until the fire is out and the stove has cooled._Be install it in the"Move and replace the refractory sure to.follow the standard safety procedure'.for access cover. working with dusty materials: wear safety goggles and 7. Replace the fireback' the five bricks and their clip, a dust mask. the left and right wedges, and the throat. When you The procedure for replacing gaskets is the same, install the lower fireback,,be sure to align the two regardless of the gasket location. Follow these eight slight recesses in,its bottom forward edge behind, steps-' the maiing,tabs on thefirebox floor. (Fig:43)lWhen 1. Remove the existing gasket by grasping an end and you install the wedges,'be'sure to place-their rear' pulling firmly. (Fig.47), vertical edges against.the outermost left and right 2. Use a wire brush or the tip of a screwdriver to clean edges of the.lower fireback,to ensure a good seal the:channel of any remaining cement or bits of g m asket. between the,lower fireback,anci.the stove's outer Fleove stubborn,deposits of cement with a cold chisel back.Tap them downward to seat them snugly, but if'necessary. (Fig:47) do not overly:tight. 8.. Clean the chimney and chimney.connector.. Operate the stove.in your usual manne'rfor two weeks, inspecting,the chimneyand the chimney connector frequently during this period. If creosote does not build up as fast; it is,likely that the , performance change was caused by fly ash deposits — on the catalytic element. However, continue the - inspections of the chimney'system for a'few weeks,to ensure that proper performance continues. sr561 If.you continue to find a significant creosote buildup or, Fig,-47 Remove gasket then clean'channel with wire brush. if'you continue to see,excessive'smoke from the , 3: Determine the''correct length of.the appropriate- chimney,the catalytic'element will need to be replaced. sized gasket by laying it out in the channel .Allow,an Contact your nearest"Vermont Castings'Authorized extra a.-2".(25-50 mm),:and mark the 'spot.to be cut. Dealer for information about a replacement element. 4. Remove the gasket from the channel; place it on a NOTE: lJse only the replacement catalyst supplied by wood cutting surface;,and cut it at the marked spot with a Vermont Castings Majestic Products Company a utility knife. dealer. Twist the ends slightly to'keep the gasket from unravel= 7 Reing'• - - . - . 5. Lay an unbroken 1/8" (3 mm) bead of gasket cement Your Defiant uses fiberglass rope gaskets to make"a in the newly-cleaned channel. (Fig.,48) tight seal between some parts. With use`,"particularly 6..Sta'rting at one.end, press the gasket into the on moving parts, gaskets can,become brittle'and. channel. (Fig..48) Ensure a good joint,where,the'' compressed and_ .can begin to lose the ir.'effectiveness. gasket meets before trimming any excess. Do not These will need periodic replacement. overlap the gasket.ends or leave ends with ragged The sizes of replaceable gasket are listed below, along, edges. . with their.application§. Gasket Diameter......And the Parts it Seals 5/16" The griddle to the stove top (wire reinforced,gasket) 5/1.6" The damper to the upper fireback; the, front doors to the stove front; and the r doors to each other:: . 3/8" The ash door to the.front of the bottom panel " If you need to change a gasket, first obtain an appropri-, ate replacement from your Vermont,Castings,Majestic ST561 Products Company Authorized Dealer: Fig.48 Lay a bean of gasket cement then press gasket in' , place.- 32 Vermont:Castings Defiant 7. Press the gasketed part firmly against its normal Inspect the system every two weeks during the heating mating surface to seat the gasket evenly,in its channel. season as part of a regular..maintenance schedule.To Close and latch the door to do this; or tap other parts inspect the,chimney, let the stove:cool completely. with the rubber mallet (or hammer/block of wood). Then,using,a mirror and a strong light, sight up B. Clean any excess cement from,around the channel, through the flue collar into the chimney flue. If you then let the cement that holds the new gasket dry cannot inspect the flue system in this fashion, the thoroughly: % stove must be disconnected to provide better viewing access. Adjust the Door Latch If Clean the chimney using a brush the same size and The stove's doors may need adjustment after you have shape as the flue liner. Flexible fiberglass rods are regasketed them. Initially, it may require loosening.the used to run the brush up and down the liner, causing latch to accommodate the new gasket; after a,few, any deposits to fall to the-bottom of the chimney where Weeks, it may need tightening to compensate for they can be removed through the clean-out door. compression of the new gasket.The directions for' Clean the chimney connector by disconnecting the adjusting the latches are on page 28. sections,taking them,outside, and removing any Permanent Defiant _ deposits with a stiff wire brush. Reinstall the connector sections after cleaning, being sure to secure the joints Other gaskets form.seals between non,-moving parts, between individual sections with sheet metal screws. Out these are not subject to the same wear and Bete- If you cannot inspect or clean the chimney yourself, . rioration as gaskets on moving parts. It is unlikely that If your local Vermont Castings dealer or a . you,will ever need to replace'these gaskets unless the involved parts are disassembled and then put back professional chimney sweep. together. If this is the case, the job should be doneAnnual Maintenance only by a qualified service technician.,,, 5/16" diameter gasket seals the following parts: Every Spring, at the end of the heating season, per- The lower Iireback to the back panel form a thorough cleaning, inspection and repair: • The left and rightair plates (inner sides). • Thoroughly clean the chimney and chimney connector. • Inspect,the chimney for damage and The Chimney System deterioration.Replace weak sections of prefabricated chimney. Have a mason'make repairs to a masonry chimney. Your"Defiantis designed to reduce creosote build-up Inspect the chimney connector and replace any significantly. However, regular chimney inspection and damaged sections. maintenance must still be performed.-For safety, good Check gasketing for wear or compression, and stove performance, and to protect`your chimney and replace if necessary. chimney connector, inspect your chimney and chimney Inspect and clean the catalytic element. Lightly clean connector on a regular schedule. Clean the system if the refractory assembly that houses the element but be necessay. Failure to keep the;chimney and connector, careful not to damage the refractory material, which is system clean can result in'a serious chimney fire. very fragile. When wood is burned slowly, it produces tar, organic Clean the glass.Ash left on the glass can etch it, vapors and'moisture that combine to form creosote. resulting in a chalky appearance.Also check for 1 cracking; replace if needed. The creosote vapors condense in the relatively cool Check door and damper handles for tightness.Adjust chimney flue of,a slow-burning fire.As a result, creo- if needed. sole residue accumulates on the flue lining. When Check heat shield screws. Tighten as necessary. ignited, this creosote makes an extremely hot fire Clean dust from the inner sides of bottom, rear and within the flue system that can damage the chimney connector heat shields. and overheat adjacent combustible material. If a Use a clean, dry, fine-bristle wire brush to remove any significant layer of creosote has 6ccumulated,-1/8" (3 built-up accumulation,on the top of the griddle. It.is mm) or more—it should be removed to reduce the normal for the griddle to darken with use, and this is not risk of a chimney,fire. treatable. If you do experience-a chimney fire, act promptly to: Remove ashes from the ash.pan.and replace with •Close the damper and thermostat lever. moisture absorbing material,(such as cat litter) to keep eGet everyone out of the house. the stove interior dry. Call:the Fire Department. • Touch up the paint on black stoves. 33 Vennorit Castings Defiant. • • • Catalytic Combustor In any chemical,reaction, including the combustion wood;.coal, household trash, colored papers, metal process, there are certain.conditions which must be 'foils, or plastics. Chemical chimney cleaners.may also met before the reaction can take place. For example, . contain'harmful elements. The.safest approach is to a reaction-may require a certain temperature, or a burn only untreated, natural wood. . certain concentration of the reactants (the combustion gases and oxygen),'or a certain-amount of time. Flame Impingement Catalysts act at a molecular,level to change'these The catalytic element is.not designed for exposure to requirements;.though they are not changed themselves direct flame. -If you continually overfit1e your Defiant, during the.reaction. In the Defiant's secondary, com the:cfiemistry of the catalyst coating may be altered; bustion chamber.the catalyst reduces the temperature inhibiting the combustion,process. Do not use your at which secondary combustion can start.from the Defiant with,the baffle removed or'damaged, as it 1000 - 1200" F. (540- 6500 C) range to the 500 shields the catalytic element from direct flame. 6001F. (260 -�315° C) range, increasing efficiency;and Thermal degradation of the ceramic base may also reducing creosote and emissions: occur, causing,the element to disintegrate. Stay within The catalytic,reaction does have some limitations of its the recommended guidelines of.the Operation section. own. Primary among these is that the reactants (the gases) come into close physical contact with the Overfiring catalyst itself:;. At low firing rates, especially with a large load.of fuel, To ensure the necessary,contact, the catalytic element the catalytic element can become overloaded with in your Defiant is a ceramic base in the shape of a gases which do not burn in the firebox. This puts honeycomb. Each of the honeycomb's many surfaces increased strain on the catalytic,element, causing it to carries'a coating of the-catalyst(usually a noble metal operate near or even beyond the high end of its normal, such as,platinum or palladium). The large surface area temperature range.--An immediate sign of this is a low exposed in this way ensures that the combustion rumbling sound,or.a sound.like a small gas torch, t. gases have the.greatest opportunity to come in contact coming from the stove's rear chamber. If you frequently ; y with the catalyst. hear such a sound, or,continually see a bright glow. Loss of.catalytic'activity will be,apparent in several through the baffle,.openup,the stove's primary air ways. First you may notice an increase in'fuel con- valve to make the',fire burn more cleanly in the firebox, sumption. Second, there will be a visible increase in and cut back on the size of your firewood load. Essen-: the rate at,which creosote builds up in your chimney tially the,catalyst is an afterburner, and will last longer connector system. You may also notice a heavy under lighter loads. discharge of smoke from the chimney. There are a numb erof'catalytic problems which can cause loss of Mechanical I Damage activity: If the element is mishandled, damage may occur. Always,treat the element carefully. Remember the catalyst is made of a ceramic material; treat it as you. .While the honeycomb pattern ensures good contact, it would fine china: Hairline cracks will not affect,the also.-increases the resistance,to flow of:the combustion performance of the catalyst, as long'as the steel'sleeve gases;and,.because of the many surfaces;.provides holds the element in the proper position. more-places for creosote and fly ash to deposit. It is _ _ important to follow the operating instructions ih order to minimize these deposits, and to periodically inspect The surface coat may peel if the'catalytic element is your catalyst for signs of blockage: frequently subjected to excessive temperatures.. Follow the operating instructions:carefully to'avoid this . Masking and • .isoning type ofidamage., While'the.catalyst itself does not enter"into the com_ - bustion process, certain elements, such as lead and ' sulfur, canattach,to the'active sites on the surface'of Every Vermont Castings' Defiant is equipped with the honeycomb. Though the catalyst is still there, it is either a Corning"Long-Life"®or an Applied Ceramics covered, or masked, by the contaminant-.and cannot combustor.:The products are,equivalent. #unction.. To avoid tnis;situgtion; it is irimportant'not to if you must ship your catalytic element for any reason, burn anything in your Defiant that is a source of these remember its fragile nature. Place the.element in a contaminants., Particularly avoid painted or`treated plastic bag, and package'it with a generous amount of 34 shock absorbing material. 35 Vermont Castings Defiant Appendix: Chimney and Fireplace Haza rds B A. Improper chimney height. The top of the chimney OA must be at least 3 feet higher than the spot where it passes through or past the roof, or two feet higher than everything else within ten feet horizontally, whichever is higher. B. Deteriorated chimney cap �V >'I C. Structural defects indicated by creosote stains on v outside of chimney D. Blockage within chimney E. Improper clearance between chimney and nearby E combustibles (less than 2" -check local codes) K. Loose or leaky cleanout door For a ti• = 0 fireplace f D t� F. Improper clearance between smoke chamber and F framing materials- (less than 2" -check local codes) G. Creosote buildup on smoke shelf G H. Structural deterioration I. Loose or broken bricks or mortar J. Insufficient hearth depth.The hearth must extend =-r 16" (1 S"/460mm in Canada) beyond the fireplace H opening.With a fireplace insert, or a free-standing t stove vented through a fireplace, the hearth must = extend 16" (18"/460mm in Canada) beyond the front door opening of the stove or insert. ti• � I K - ■ s H . ST562 35 Vermont Castings Defiant 13 15 --- 17 25 21 Q 18 � � �. 28 0 16 5 69 zz ' 24 23 � 20 19 8 37 /A � �. 12 i i 9 26 45 � ® �� • 6310 ,. 35 t1 47 27 �79 3 � 44 46 73 81 8I =II 38 82 29 59 80 � c 48 77 i 61 33 39 51 78 8 ♦ 83 IT 98 r, 54 70 64 62 66 85 43 41 (y 53 0 . -- 76 6 a ' 56 � 55 i i 75 i 7 65 ° 0 � 80 � � , 58 68 49 -------------- 67 78 Vermont Castings,Majestic Products reserves the right to make changes in design,materials,specifications,prices and discontinue colors and products at any time,without notice. Defiant WoodburningStove Item/Model Number 'Part.Number Item/Model Number _ P art_Number 1. Secondary Air Cover Plate 1601492 7. Left Heat Deflector- — 1608629_ 2. Secondary Air Probe Assy_ 1601489 8. Right Heat Deflector 1608630 3._ Seconda'ry Air Link. _ 1601486, 9." Refractory Assy(Body only) _ 1602512; 4. Secondarr r Air Flap 1601490 10.. Catalytic Combustor _30001152 5. Griddle Gasket _ 1208668 11. Refract_yr Access Panel _ 1602511 6. Back 30001581 12. -Thermostat Friction Spring_; •1201846 36 ` V£rDont Castings Defiant Defiant (continued) --' lf6iiifModel Number Part Number ---It�m- Mad-J-Nurillier Part Number 13. Left Griddle Quadrant 1301807 49. Andiron Shelf 1300640 16. Griddle Handle 1600657 52. Door Latch Assy__--- Upper Firebrick' 1300633 57. Ashdoor Bottom Hinge Support 1300642 -' ---^-^-~^ 67. Left Door 130062644. Left 36. Thermostat Handle Base Assy_____5004264 72. Front Door Handle&Shaft 5004-237 -.---_-_'__--___---- 80._---__^^---___--.e Pin--_-___� ' _ . 600650 1-.«00620 _-___-_- --_.- 47. Firebrick Retainer 1600066 ea- _ -- . 120&94 8� _-12�1243 Gi 30001090 NOTES: 87. Flue Collar -_-- - -- ' _ - ___'-__-__---- - -30OO1�76 88. L�Q 0OO1583 |n�� -a~mma��muh�� �'-_' �ffm� !� —Oo�- 59yg 28 'rioht' mean oo you face the stove. | When ordering parts, be sure to mention the otove's ' model number. When ordering external pars, be sure ho specify color. 1.|no|uded|n Item#1Q. #5OOOU38 Upper FivabaokAooy 2.Nch interchangeable, due hoa heat-reflective cneting on the room side of the glass. 3.Included in Item #50. 50O8824 Primary Air Aouy. 4.Included,in #5OO4282 Ceramic Handle Ausy. The hardware in the Defiant isin standard sizes; most bolts are 1A"diameter by20 threads per inch.Any hardware store can supply replacement hardware ifyou specify bolt diameter, number nf threads per inch and length. ' ]7 | DIRECT VENT GAS HEATER DV25 OwNWsGumE . INSTALLATION, OPERATION AND MAINTENANCE PROCEDURES FOR #2642 NG25 AND #2643 LP25 WARNING: If the information in this manual is not followed exactly,a fire or explosion may result causing property damage,personal injury or loss of life. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHATTO DO IFYOU SMELL GAS • Turn off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch: do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas suppliers's instructions. • If you cannot reach your gas supplier,call the fire department. Installation and service must be performed•by a qualified installer,-service agency or the gas supplier. WARNING: Improper installation,adjustment,alteration,service or maintenance can cause injury or property damage.Refer to this manual for correct installation and operational procedures.For assistance or additional information consult a qualified installer,service agency,or the gas supplier. pESlap R�,� Iar 7J VCIA��s �-�1►► ROVED �fATIF1E� •' �"J Tested and listed to ANSI Z21.44.1995 and CAN/CGA-2A9-M86 Table of Contents Specifications/Shell Dimensions General Information .................... Installation Requirements ' Assembly Procedures 9 Operation ..................... Maintenance Illustrated Part List........................................... 21 Wiring Diagrams .............................................. 22 Appendix ............................ , ............6.......... 23 Warranty............................................ Back Cover ATTENTION CONSUMEA.M IN ORDER TO ENSURE SAFE AND EFFECTIVE INSTALLATION,THIS UNIT MUST BE INSTALLED ONLY BY A QUALIFIED AGENCY,INDIVIDUAL; FIRM,CORPORATION,OR COMPANY THAT IS EXPERIENCED IN THE INSTALLATION,REPAIR AND SERVICING OF THIS TYPE OF APPLIANCE AND IS FAMILIAR WITH THE BUILDING.CODES AND INSTALLATION TECHNIQUES APPROPRIATE IN YOUR AREA.CONTACT YOUR HEARTH PRODUCTS DEALER OR LOCAL GAS SUPPLIER FOR THE NAME OF A QUALIFIED SERVICE PERSON. 1 1 PLEASE READ THIS MANUAL CAREFULLY BEFORE YOU BEGIN THE. INSTALLATION PROCEDURES.FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE,BODILY INJURY OR LOSS OF LIFE. THIS MANUALCONTAINS IMPORTANT USER INFORMATION.KEEP THIS MANUAL WITH THE FIREPLACE AFTER INSTALLATION IS COMPLETE. Specifications. DV25 Direct Vent Gas Heater/NG 2642 and LP 2643 Fuel 173.�5' LP Manifold Pressure-Min./Max.: 6.4"/10.0" Min.lnlet Supply Pressure for adjustment: 11.0"W.C. Steady State Efficiency: 74.8% AFUE : 5.8% 69.7%' Input,BTU/hr. Min,/Max. ; 19,500 / 25,000 Ignition: Piezo Thermostat:Not supplied-use only 500 millivolt type ! Weight;Firebox w/Glass&Logs:-110 lbs. Fully assembled in Freestanding Shell:-200 lbs. Dimensions Freestanding Stove Shell See Page 5 for Flue Collar Centerline Dimensions. 26 3/4" ❑F—�00❑ Valve Inlet 3 7/8' 25' 14' —� To clear Stove Leg t, F � 11 1/2' RNII n on� Valve Inlet Street Elbow I'Nipple Check local codes for approved fittings. DRAWINGS NOT TO SCALE 2 General Information The Direct Vent Gas Heater, DV25, Models#2642 and The DV25 should be inspected before #2643, is a vented gas appliance listed to the ANSI use and at least annually by a qualified standard Z21.44-1995 and CAN/CGA-2.19-M86 for service agency. More frequent cleaning Direct Vent Wall Furnaces..It is also tested to CGA. may be required due to excessive lint from Interim Requirement#41 for Direct Vent Gas Fire- carpeting, bedding material, etc. it is places. imperative that control compartments, This appliance is approved for bedroom installation, burners, and circulating air passageways in the U.S.and Canada. of the heater be kept clean. This appliance may be installed in an aftermarket` The appliance and its individual shut-off valve must manufactured(mobile)home,where not prohibited by be disconnected from the gas supply piping during state or local codes. any pressure testing of that system at test pressures in This appliance is only for use with the type of gas excess of 1/2 psig.(3.5 kPa). indicated on the rating plate.This appliance is not The appliance must be isolated from the gas convertible for use with other gases, unless a certified supply piping system by closing its individual manual kit is used. shut-off valve during any pressure.testing of the gas "Direct vent"is a term used to describe a sealed supply piping system attest pressures equal to or less combustion system in which incoming outside air for than.1/2 psig. combustion and outgoing exhaust enter and exit A 1/8-inch N.P.T. plugged tapping, accessible for through two separate concentric passageways within . test gage connection, should be installed on the inlet the same sealed vent system. gas connection. The direct vent system permits the gas appliance to The DV25,when installed, must be electrically be vented directly to the outside atmosphere through grounded in accordance with local codes or, in the the side of the house, unlike conventional venting absence of local codes,with the National Electrical systems that take air from the room for combustion and Code ANSI/NFPA 70, (latest edition),or.of-the current vent the exhaust vertically through the roof to the Canadian Electrical Code C22.1. atmosphere. The installation of the DV25 must conform to local codes,or in'the absence of local codes,with National Due to high temperatures,the Direct Vent Gas Fuel Gas Code,ANSI Z223.1 —latest edition and CAN Heater should be located out of traffic and away 1 131-149.1 and-.2 Installation Code. (EXCEPTION: Do _ from furniture and draperies: not derate this appliance for altitude. Maintain the manifold pressure at 3.5 inches W.C.for Natural Gas WARNING: This appliance is hot while in and 10 inches W.C. for LP gas.) operation. Keep children,clothing,and furniture away. Contact may cause burns or ignition of Installation and replacement of gas piping,gas combustible materials. utilization equipment or accessories,and repair and servicing of equipment shall be performed only by a Children and adults should be alerted to the qualified agency. The term"qualified agency"means hazards of high surface temperatures and should any individual, firm, corporation,or company that either in person,or through a representative is'engaged in stay away to avoid burns or clothing ignition. and is responsible for (a)installation or replacement of Young children should be carefully supervised gas piping, or(b), the connection, installation, repair,or when they are In the same room as the servicing of equipment,who is experienced in such appliance. work,familiar with all precautions required,and has complied with all the requirements of the authority Clothing or other flammable materials should not having jurisdiction. be placed on or near the appliance. Any safety screen or guard removed for Aftermarket:Completion of sale,not for purpose of resale, from servicing an appliance must be replaced prior to the manufacturer. operating this appliance. I 3 The appliance area must be kept'clear and free. This gas appliance must not be connected to a from combustible materials,gasoline,and other chimney flue serving a separate solid fuel burning flammable vapors and liquids. appliance. The flow of.combustion,and ventilation air must .CAUTION:Label all wires prior to disconnection not be obstructed. when servicing controls.Wiring errors can cause, improper and dangerous operation. iWARNING:. Do not operate this appliance with the glass panel removed;cracked or broken. Verify proper operation after servicing.. Replacement of the,panel should be'done by a licensed or qualified service person.'` Installation and repair should be:done by a qualified service person.The appliance should be Do not use this appliance if any part has been inspected before use and at least annually by a under water.Immediately call a qualified service qualified service person.more frequent cleaning technician to inspect the appliance and to may be required due to excessive lint from replace any part of the control system and any carpeting,bedding material,etc.it-is imperative gas control which has been under water. that control compartments,burners and circulating air passageways of the appliance"be kept clean. Do-not burn wood,trash or any other material for which this appliance was not designed.This appliance is designed to burn either natural gas or propane only. Figure 1. The DV25 Gas Heater/Controls. Firebox 0 Logset �K7 0 Safety Switch ice" U � Base Plate o e Pilot Assembly d- Piezo Ignitor Variable Regulator Supply Line Inlet OFF/ON/Pilot Control Knob 4 ' Installation Requirements The installation must conform with local codes or,in the Clearance Requirements absence of local codes,with the National Fuel Gas Code,ANSI Z223.1 -latest edition.(EXCEPTION: Do Minimum Clearances to Combustible not derate this appliance for altitude. Maintain the Materials manifold pressure at 3.5 inches W.C.and 10 inches W.C.for Propane). The DV25 heater is approved for installation into an In Canada,installation must be in accordance with alcove constructed of combustible materials to the the current CAN 1 B 1-149,1 and-.2 Installation Codes dimensions and clearances shown below. and/or local codes. The same clearances apply in a standard parallel The installation should be done.by a quali- installation. fled service person who is familiar with the building codes and installation techniques appropriate for your area to accomplish a g safe and effective installation. Your dealer or your local gas supplier will D be able to refer a qualified service person. WARNING: DUE TO HIGH TEMPERATURES,THE A Imo_ —CIA i HEATER SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES. c THE SURFACE OFTHE HEATER IS HOT WHEN IT l3. ea WallC9(50mm) ) IS IN USE. YOUNG CHILDREN SHOULD BE C: in. i V 37^ WATCHED CAREFULLY WHEN THEY ARE IN THE D: Max.Alcove Depth 48"((1220 m) SAME ROOM WHEN THE HEATER IS IN USE,AND THEY SHOULD BE TAUGHT TO AVOID THE HOT SURFACE., KEEP ANY OBJECTS THAT CAN Figure 2. Minimum side clearances and alcove dimensions. BURN WELL AWAY FROM THE HEATER,,AND OBSERVE THE RECOMMENDED CLEARANCES THAT F LQ1AL�\ Hearth Requirements 13 The DV25 Heater must be installed on rigid flooring. Any carpeting under the unit must'be removed. When the heater is installed directly on any combustible c surface other than wood flooring,a metal orwood panel extending the full width and depth of the unit must be used as the hearth.There are no other h rth D r ments. A Keep the Stove a Safe Distance from Surround!ng.Materials The DV25 Heater will heat nearby surfaces when operating. A safe installation requires that adequate clearance be maintained between the stove,and A—He Wall 50m nearby combustible materials to ensure that such e ne Dept C: m. eIa i 25 2" 650 mm)' materials do not overheat. The diagrams that follow D: Min.Height 521/4"(1327 mm)" illustrate the minimum clearances forth e appliance in needed for installing Vent System#5084 parallel,corner,and alcove installations. For further information on ventilation guidelines and Figure3. Dimension earances.lo ceilingoralcove. sizing specifications follow the National Fuel Gas Code NFPA54/ANSIZ223.1 Section5.3. Y 5 Wall Thimble Centerline from Floor Flue Collar Centerline from the Wall Combustible ceiling 161 i4i13 mm� A I 1526♦m—m 16 1/4'B 413 mm C 42 3/4"Min. (1086 mm) 6" E- 152 mm Figure 4. Minimum clearances to ceiling ormantel. Figure 5. Flue collarcenterline from wall,-Comer Installation. A B C Effective Minimum 91/2' 251/2' 521/4' using Wall Thimble 241 mm 650 mm 1327 mm and 2'Rear Clearance: 181/2"—�I �470 mm 6 1/2" 2"50 mm 165 mm _ t —�i 6" 1 152 mm Figure 6. Flue collarcenterline from wall;Parallellnstallation. Venting Requirements and Options Horiaontel Termination.. The maximum permissible horizontal run is 8 ft 'Approved Vent System Components ' (2.4m). The maximum vertical run ending in a The DV25 Heater_is approved to`be vented to the horizontal terminations is 12 ft. (3.6m). The vent run outdoors through an adjacent exterior wall'or must extend a minimum of 2'ft. (:6m)See Fig. 7 for. . through the:-roof.-The venting system must be specifications concerning offsets and overall vent comprised of the appropriate listed venting compo- run lengths. nents specified in Table 1. These parts.are available Figure�. 12- from DuraVent.Corporation or your DV25 dealer. All Straight vent pipe sections have a net length ------- 1 112" (37mm) less than the nominal dimension; 10 ------------- i.e., a 6"(152mm) Straight pipe'section has an W effective length of 4 1/2' (115mm).' 'o ------------------ The Appliance Adaptor 923V;when installed, .8 terminates 9 1/4' (235mm) above the stove. OK TO 'See Fig. 8 for dimensions relevant to the#5084 > -----------KSI-r------ Standard Vent System pipe. ------BOWS aB =-- OFFSET-------- R Table 1.Approved Venting Components ---------------------- � VCINO. COMPONENT, DURAVENT.NO. 4------------------ 923V APPLIANCE ADAPTOR' 923V. ----------- 990B 90'ELBOW,BLK.' 990E USE ONLY ONE 2 - 9W EL N/A 90'ELBOW,GAL. 990. BOW WITH 01 OR LESS 945G 45'ELBOW,GAL. 945 M VERTICAL RISE 908B 6"STRAIGHT;BLK.' 908B 0 ` 907B 9'STRAIGHT,BLK. 907B 0 2 2 4 B 8 906B 12-STRAIGHT,BLK. 906E HORIZONTAL RUN/.FEET 906G 12'STRAIGHT,GAL. '906 904B 24'STRAIGHT;BLK. 904E 904G 24'STRAIGHT,GAL. 904 903E 36'STRAIGHT,BLK. 903B 'I(121Frr►i) LAI #984 903G. 36'STRAIGHT,GAL. 903. #9908 N/A 48'STRAIGHT,BLK.- 902B -- - - H90813 ® - N/A 48'STRAIGHT,GAL. 902 911 B 11'-14 5/8'STRAIGHT 911 B 6 (170mm) • 984B' HORIZONTAL VENT,CAP" 984 940E WALL THIMBLE/CEILING SUPPORT BOX',940 9408 i 950E VINYL SIDING STANDOFF 950 g 1/4• 10'x 10' 982B SNORKEL TERMINATION-.14" 982 (235mm).• #923V wall 981 B SNORKEL TERMINATION-36" '981 + Cut-out*,.'' 5084 MINIMUM HORIZONTAL VENT KIT N/A 988G WALL STRAP 988 941 B CATHEDRAL CEILING SUPPORT BOX,• 941 42 3/4' 953E STORM COLLAR 953 (1085mm) 963G FIRESTOP SPACER • '963 26 3/4" 943G. FLASHING 0/12 6/12 (680mm) 943 25 1/2' z 943S FLASHING 6/12-12/12 943S (648mm) 991G VERTICAL TERMINATION CAP 991• 'Included In Vermont Castings Standard Vent System#5084 Figure 8. Standard Vent System#5084 through-a combustible wall,with the minimum approved rear clearance, (2).'. " The 10"x 10°wall cut-out will provide the required . Figure 8. Minimum vent dimensions. clearance o/.1'around the vent pipe. 7 Vertical.Vent Termination Vent Terminus Clearances The maximum permissible vertical run is 25 ft. When planning the,installation, the location of the (7.5m) measured from the heater flue collar to vent terminal and clearances must be considered. the lowest discharge opening at the termination. Some of the most common clearances to keep in See Figs. 9 and 10 for offset and run length mind are shown in Fig. 48. specifications. IMPORTANT: ALL VENT CLEARANCES MUST BE MAINTAINED:CHECK,YOUR VENT TERMINUS. .. 25 CLEARANCES AGAINST FIG.48; PAGE 23, APPENDIX A. The vent should be placed so that people cannot be burned by accidentally touching the vent 20 surfaces when the stove is operating. LL The vent termination should be located where it ocannot be damaged by such things as automobile 0 15 ALLVERTICAL doors, lawn mowers or snowblowers and it should W TERMINATIONS be located away,from areas'where it could become REQUIREUSE -obstructed by snow, etc. THE 2': Some,considerations are: 10 RESESTRICTOR PLATE. • Obstructions or impediments to venting. N: cci • Nearby combustible materials that could come into contact with combustion exhaust gases. e 5 i • Other nearby openings(within 9' (23mm)) through which exhaust gas could re-enter the building. 0 • All vegetation within 3' (.9m)that may interfere 0 2 with the draft. HORIZONTAL RUN I FEET • Vinyl•siding requires protection from Figure9. Maximum Offset/VentRun. vented heat Immediately around the vent opening: Use.Vinyl Siding Heat Shield Kit #950 or.950B. Lowest Discharge Other factors that influence where the installation Opening will be sited include the location of outside walls, Listed Cap where additional heat may be desired in the home, a where the family members,gather most regularly, Listed and perhaps most importantly,,the distance limita- Gas vent H 12, X tions of the venting system. Roof Pitch Is X/12 H -Minimum Height from Roof to 0 0 Lowest Discharge Opening o 0 -Roof Pitch H(Min.)Ft. 4 000 Flat to 6/12 1.0 HOT, 6/12 to 7/12 1.25 Over 7/12 to 8/12 1.5 Over 8/12 to 9/12 2.0' Over 9/12 to 1 Oh _2.5 Standard vent cap Vinyl shield Over 10/12 to 11/12 3.25 Over 11/12 to 12/12 4.0 Figure 10. Vent(Chimney)Height. Fig. 10-A. Positioning the vinyl siding shield. . 8 Q WARNING: •ALWAYS MAINTAIN',REQUIRED CLEAR- ANCES(AIR SPACES)TO NEARBY COMBUS= TIBLES TO PREVENT FIRE HAZARD:DO NOT. FILLAIR.SPACES WITH INSULATION:ALL VENTING COMPONENTS MUST MAINTAIN A 1"(25MM)CLEARANCETO COMBU§TIBLE MATERIALS. THE GAS APPLIANCE AND VENT SYSTEM. ; MUST BE VENTED DIRECTLYTO THE'OUT= SIDE'OFTHE BUILDING,AND NEVER BE.; ATTACHED TO A CHIMNEYSERVINO A; SEPARATE SOLID FUEL OR GAS -BURNING-'-'. APPLIANCE.EACH DIRECTVENTAP PLI ANCE MUST USE.IT'S OWN SEPARATE VENT $Y$TEM COMMON VENTS ARE -ROHIB , ITED REFER TO THE MANUFACTURER'S IN - STRUGTION$INCLUDED WTH ITH E VENTING SYSTEM FOR COMPLETE INSTALLATION 4 PROCEDURES `s IMPORTANT F1Th.1,orizontal termination must not be re- cessed into the exterior wall or siding. • Horizontal vent runs must be level or rise 114" per foot toward the vent termination. • Clearances around the vent termination must I be maintained. •Parallel installations with minimum wall clear- ance have restricted access for connecting the'Horizontal Vent Cap straps to the vent Pipe.See Page 13 of the,Assemblysection for recommended installation procedures. I .. I g Assem, bly Procedures Remove WARNING packing Rear material. FAILURE TO POSITION THE PARTS IN shroud Carton ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE ONLY PARTS _. SPECIFICALLY APPROVED FOR.USE WITH Control THIS HEATER MAY RESULT'IN PROPERTY switch . DAMAGE OR PERSONAL INJURY. Cover THIS HEATER'AND COMPONENTS ARE `o VERY HEAVY. HAVE ASSISTANCE AVAILABLE FOR ASSEMBLY. o Unpack the DV25 Firebox, Logset and Stove Shell Cut the shipping straps and remove the Rear Shroud from its carton. Remove the cardboard'packing material from Figure 12., DV25 Firebox with,Switch Cover as shipped. the top of the firebox; Fig'. 1.2. Do not remove the.firebox from the shipping pallet yet. Tools Required • Phillips screwdriver(stub) • .power drill • utility knife reciprocating saw • metal drill bits: size 28(.140"/3.5mm)and 1/2"dia. ZIA Parts Bag Contents: •, 9 Phillips 1/4-20 x 5/8"screws • 4 Phillips 1/4-20 x 3/8",screw s '4 Phillips# 10 x, 1/2 sheet metal screws • 3 Phillips# 10 x 1" sheet'metal screws', • 1 Wire tie �. 1 Vent Gasket o • 1 Vent Restrictor.Plate • Owner Registration Card See Page 22, Fig. 47/Scew Identification Chart. Remove the Log Set Figure 13. Remove the three frame screws from the The Log Set has been packed inside the firebox in a locations indicated. protective wrap. The Glass Panel must be removed to install the Log.Set onto the burner. , • Use a Phillips screwdriver to remove the three screws from the glass retainer frame. Fig. 13: Keep the screws Lock and orient thQ Elbow Elbow and Outer' for later re-installation with the other 9, 1/4-20 x 5/8" Adaptor together in phillips screws in the parts bag. the appropriate •.Carefully remove the glass and,frame assembly and direction before place it out of the.way on a flat, padded surface such drilling the Pilot as a counter protected by a.towel. Outer-.Adaptor— Adaptor.o the (crimped end p Unpack the cast iron stove shell parts.from the shipping down) carton. Inspect each part.for shipping damage and set it aside on a protective surface. Porcelain enamelled surfaces are fragile:Handle porcelain enam- oiled castings tonderly..': Drill Drill Before you begin assembly, read this section;of the manual to familiarize yourself with the procedures.The,, installation will be most easy if you follow the steps in the order presented. Figure 14. Pre-drill pilot holes into the Outer Adaptor pipe. 1,0 Venting Pre-assembly Wingbolt The vent Outer Adaptor pipe must be pre-fit and its pilot 8 holes drilled before proceeding with the heater assembly. •.Insert the Outer Adaptor Pipe, seam facing back, into the flue collar. If applicable, insert'and fully engage an �� b elbow into the Outer Adaptor pipe and rotate the pipe so that the elbow is facing the appropriate direction for . connection to the vent termination. Fig. 14. • Drill .14"dia, pilot holes into.the pipe through the three existing screw holes in the firebox flue collar. Remove the Wingbolt pipe. Heater Assembly 1. Attach the Rear Shroud to the Left End plate by Figure 16. Secure Right End to the Rear Shroud. aligning the key holes with the two wingbolts in.the side. If necessary, turn the wingbolts to orient the blades vertically. Fig.15. Slide the shroud downward.to engage it behind all three washers on the side plate Hang Switch bolts and then tighten both wingbolts. a Cover over Flue, 2. Repeat Step 1 to attach the Right Side Plate to the Collar. Rear Shroud. Fig. 16. Move this assembly close to the stove's final position. Align the two side plates to be perpendicular to the Back Panel as in Fig. 17. 3.Hang the Switch Cover over the flue collar rim, as in Fig.17, to keep it out of the way while installing the Rear Shroud firebox. DO NOT PULL ON THE SAFETY RELAY WIRE LOCATED OVER THE FIREBOX. Lift the DV25 firebox Safety Switch + assembly as a unit and slide it back to position it within t •�» f the shell. The base of the firebox should rest on the side support shelves as in Figs.17 and 18.The large 1 o n. washer at the forward leg of each Side Plate should engage the corresponding notch in the Underside of °- 90• the firebox.base as shown in Fig. 18. Properly posi- tioned, the firebox will be level and locked in place. If Sa„ety elay, not, adjust the levelling screw in the foot of each leg to keep the entire unit level. o , o IMPORTANT! Confirm that the Safety Switch Is properly positioned.See Fig.40, page 19. Figure 17. Align both 'sides with the rear.' If you are installing the optional convection Fan Kit #5081, proceed to Step 4. If you will not install a Fan Kit, proceed to Step 7. Wingbolt 1 L.10N Left Rear — Side b_ Shroud Notch Base Washer Figure 18. Install the Firebox Assembly. Be sure that the Wingbolt b two large front washers engage the notches on both Figure 15, Secure Left End to the Rear Shroud. ends of the Base. 11 4. The fan kit consists of a Blower Assembly and a 5. Remove the.panel at the bottom of the Rear Shroud Rheostat Assembly that are connected by a cable. and secure the blower assembly to the firebox base Fig. 19. The Blower Assembly mounts to the bottom using the two hex bolts supplied with the kit. Fig. 20. rear of the the stove and the Rheostat mounts.within 6. Remove the plug from the Control Switch. Reach under the switch box on the left rear corner of the stove. The. the Back Panel and feed the Fan.Rheostat/Snapstat Rheostat contains a"snapstat"which senses the assembly up to the top of the firebox, Secure the temperature within the stove heat exchanger and rheostat assembly to the Switch Cover the sheet metal automatically turns the fan On (or Off) above (or screws supplied with the fan kit. Fig. 21. below) approximately.•109°. The Rheostat also provides a range of fan speed settings from Off 7. Install the Control Switch Cover onto the Back Panel (which overrides the Snapstat function)to High. using the four#10 x 1/2" sheet metal screws supplied in the parts bag. Fig. 22. Unpack and inspect the Blower assembly. Confirm that the fan spins freely. Push the Control Knob onto the rheostat shaft. Secure the wire harness to the hole in the side of the shroud using the plastic wire tie supplied. Fan-Kit users:Be sure that the snaptat extension is positioned against the cast iron at the top of the firebox'. THIS APPLIANCE IS EQUIPPED WITH A THREE-PRONG (GROUNDED) PLUG FOR Engage the snaptstat YOUR PROTECTION AGAINST SHOCK extension through the notch in the Cover. --- HAZARD AND SHOULD BE PLUGGED Hex Nut DIRECTLY INTO A PROPERLY GROUNDED - /--- THREE-PRONG RECEPTACLE. DO NOT CUT OR REMOVE THE GROUNDING PRONG zvo a FROM THIS PLUG. --------_____ a o ------------ Blowero , __ Assemblyo 0 1/2"sheet metal screws 1 - ® Figure 21. Install Rheostat/Snapstat assembly. �.\ Rheostat/Snapstat Extension Assembly Control Knob 1/2"sheet metal screws , Figure 19. Fan Kit Components a , a , Back Panel , Wire Harness 6 Hex Bolts C--� WireTie Lower Panel `— — - ° Figure 22, Install Off/On Switch Cover plate. Place Figure 20. Install Blower. the four sheet metal screws as shown. Push on the knob. 12 'l9. Connect the wall thermostat leads to the double terminal block at the lower left corner of the firebox base. Fig. 23, Either wire:may be connected to either Inner Adaptor — terminal. Note in the table below the appropriate ' gauge wire to use for the,-length,of lead needed. Use only a 500 millivolt thermostat. Wire Gauge' Maximum Run. 18 .•40' 20 25' 22 16' .1/4-20 x 3/8' Phillips screws I To ease access,remove I the lower panel(5 screws)from the rear Restrictor Plate- shroud. See Figs.7 and 9. Page 6-7 Terminal Block I I � O Figure 23. 500 Millivolt Thermostat Connection. Vent Gasket Attach the.Venting I The'DV25 is approved for installation only with the vent components listed on Page 6. Follow the..•vent manufacturer's instructions exactly.,. Paint Option.- Porcelain Enamel Stoves You may wish to use the Medium-temperature paint Inner Flue., provided to paint the vent components to'match your Collar, stove before assembling the system. Appliance Adaptor Connection 1. Attach the'adhesive-backed gasket(located in the parts bag)to the flat flange of the Inner Adaptor Pipe. Fig.24..if you need to use the Restrictor Plate, attach the gasket to that plate and install the plate,gasket-side down;.under Figure 25. Secure the:lnn_er Adaptor to the flue collar. the Inner Adaptor'Pipe.'See Figs:7 and 9 to determine if you need to install the Restrictor Plate., 2. Attach the Inner Adaptor Pipe to`the stove with three 1/4_ 20 x 3/8"Phillips screws(see parts bag).Fig.25. 3. Insert the Outer.Adaptor pipe into the flue collar as previously fit and-secure with three#10 x 1"sheet metal 3 Sheet metal screws supplied in the-parts bag.:Fig.'26, screws = Use a stub-handle screwdriver. Adhesive-backed Gasket Inner Appliance Adaptor Pipe Figure 24. Attach the gasket to the Inner.Adaptor. Figure 26 Install'the Outer Adaptor. 13 Complete the ,Vent System : Install the rest of the vent system according to the manufacturer's instructions included with the components. NOTE: If the heater will be installed parallel to the wall with minimum rear clearance(2") use the following Exterior Wall —- Interior Wall procedure, in conjunction withr the vent manufacturer's instructions, to complete the vent connection. Be sure to follow the venting guidelines in the Installation,section — 2 �— (55 , and Appendix A of this manual as well as those specified mm) Trim by the vent manufacturer. Horizontal Vent Standard Parallel Installation (min. Cap rear clearance) Mounting Strap 1. Cut the opening. Determine the location and cut and frame an 8 5/8"x 8 5/8 square hole in the wall. Be sure that the exterior and interior cutouts are level with each other. Figure 27. Trim the mounting straps. 2.­ Trim the Straps. Install the Vinyl Siding Stand-off if applicable. Position the'Horizontal.Vent Cap within the opening on the outside wall and temporarily secure it in place with one of the wood screws provided. Mark and trim each of the mounting straps to extend no more than 2 1/4"(55mm)beyond the interior wall. See Fig.27. Remove the Vent Cap from the outside wall. Wall 9/16"dia: Thimble Access 3. Drill Wall Thimble. With the stove installed at Plate Hole minimum clearance, insufficient room exists to back the wall thimble away from the cutout to allow access for attaching the vent cap mounting straps. Before i assembly, drill one 9/16"dia. access hole through the side of the thimble near the seam to allow attachment I 1 1/4'(Wmm) of the straps. Fig.28. 4. Locate the Stove. Position the stove with vent assembly(including appliance adaptor, elbow, straight section and wall thimble) in the final location. Figure 28. Drill out the wall thimble access hole. Be sure to center the straight pipe section within the wall cutout. S. Install the Vent Cap. Run a bead of non- hardening mastic to seal around the outside edge of the Horizontal Vent Cap. The arrow on the vent cap Seal around the entire -should point UP. Position the cap in the center of the edge of the _ Wall hole on the outside wall, making certain that the cap Vent Cap -- Thimble and pipe mate properly. Also, be sure that the mount- ing straps are visible through the wall thimble access $ _ Secure hole. Secure the Vent Cap to the wall with the wood U straps screws provided. flu through Access Hole 6. Secure the Straps. Rotate the Wall Thimble around the elbow to provide access to secure the two mounting straps.to the straight vent pipe. Attach the straps with the sheet metal screws supplied with the Vent Cap. Fig. 29. 7. Secure the Wall Thimble. Rotate the thimble to Secure Cap and Thimble to walls hide the access hole. Secure the thimble plate to the interior wall using the four screws provided. Figure 29. Secure the straps to the vent. Install the Log Set Install the Front and 'Top Plates 1. The logs are pre-assembled and install as a unit. 1. Grasp the Front Plate by the window bars and lift it into Center the Log Set on the burner behind the cast iron position engaging the two steel tabs behind the adja- tabs. The Logs must set tight against the top of the cent bosses in the Side Plates. Fig. 32. Then seat the burner plate. Fig 30. Front against the sides so that the tabs at the bottom lip •2. Position the glass and frame against the firebox and engage with the notches in the stove legs. hold it in place with one hand against the top center When properly installed, the bottom of the Front Plate of the frame. The bottom'of the frame will be sup- • cannot be pulled away from the sides without also lifting it. ported by the iron ledge. Adjust the-glass as needed MOTE: Be sure that the steel safety switch,relay cable is so that it contacts the gasket evenly all around. In the positioned over the Heat Exchanger door on top of the parts bag, find the 9 1/4-20 x 5/8" screws needed, firebox. See Figs. 32 and 40a. Install and turn them so that they are only finger tight. 2. Place the,Top Plate over the sides and front.The upper 3.To avoid uneven pressure on the glass when tighten- edge of the side plates should seat into the channel in ing the screws, tighten them alternately, one half-turn the underside of the Top. Fig. 33. at a time, until they are all snug. Fig. 31.Tighten the screws only by hand,and do not over-tighten. Do not use power tools. Over-tightening can break the glass. Safety Switch Relay Cable En age steel tabs be the cast Cast Iron 5i; Cast Iron \ Iron bosses. Tab Tab S u$ v r p {r m Figure 30. Align the Logset with the screws on the Control Door a burner plate. •�� Bottom Tabs engage no in the leg. 5 1 7 Figure 32. Install the Front Plate. 9 11 y� cS"' 4t-�'#tip �� .i� °�a�:�q` xru � • 12 �dlF 9 0 2 f s 1 GJ x€ •i}✓"A%R%: Imo,y;S•'�`^_Yq 1^7is% s C �rt�4 N; D�y D� Figure 3l. Tighten the screws in an alternating se Figure 33. Install the Top Plate. quence. 15 Burner'Conversion, Connect the Gas Supply' The DV25 Gas Burner 2642 is shipped config• Check the rating plate on the cable under the valve to ured to bum Natural Gas only.,. confirm that you have the appropriate'burner for the type. The DV25 Gas Burner 2643-Is shipped config• of fuetao be used. ured to bum Propane only. The label on the front of the.,stove:Indicates THIS APPLIANCE SHOULD BE CONNECTED ' Which fuel the burner is configured to use. TO THE GAS SUPPLY ONLY'BY A QUALIFIED e `If cony®rsion for use of either alternative gas is GAS'SERVICE TECHNICIAN. FOLLOW ALL , . LOCAL'.CODES. necessary it should be done at this time,before connecting the gas supply line.Conversion should be made only by a qualified service The DV25 Heater and its individual shutoff:valve must technician following the Instructions supplied, be disconnected from the gas supply piping during any with the Kit. pressure testing of that system at test pressures in excess of 1/2 psig(3;5 kPa). To convert from Natural Gas to Propane;use. The DV25 Heater must be,isolated from the gas supply only'LP Conversion Kit #2659 with,this stove. piping system by closing its individual manual'shutoff valve during any pressure testing of the gas supply piping To convert from Propane to'Natural'Gas,use only NG Conversion,Kit #2658.with this stove. system at,test pressures equal to or,less than 1/2 psig. 1. Connect the main Gas Supply to the control valve' inlet.`Fig.34. A 1/8-inch N.P.T. plugged tapping, Ty accessible for test gauge connection, must be installed on the inlet gas connection. THE CONVERSION KIT SHALL BE INSTALLED BY 2. Test for teaks at all joints before operating. A QUALIFIED SERVICE AGENCY IN ACCOR- DANCE WITH THE MANUFACTURER'S INSTRUC. This completes assembly procedures for the'DV25 Gas TIONS AND ALL APPLICABLE CODES.AND Heater. REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION.IFTHE INFORMATION IN THE INSTRUCTIONS IS NOT.FOLLOWED EXACTLY,A_ . FIRE, EXPLOSION,OR PRODUCTION,OF CARBON MONOXIDE MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY,OR LOSS OF LIFE: THERE'MUST BE A GAS SHUTOFF THE QUALIFIED SERVICE AGENCY PERFORMING BETWEEN THE STOVE AND THE.SUPPLY:. THIS WORK ASSUMES RESPONSIBILITY FOR' With'Natural Gas,use a 3/8"or l/2'natural THE PROPER CONVERSION OF THIS APPLIANCE gas,supply line with an input of 25,000 BTUs at a WITH THE,KIT. manifold pressure`of 3.5"and minimum inlet supply for adjustment of 5.0"W.C. With Propane,use a 3/8"or'1/2'propane gas supply line with.an input of 25,000 BTUs at a Safety Switch manifold pressure of 10.0'and minimum inlet supply for adjustment of 11.0'W.C. This heater is`equipped with a.safety switch .which will prevent burner operation If the relay pin becomes disengaged for any reason.Check that the relay pin Is.in place before attempting •.r -p to operate the'heater. See Fig. 40, Page 19. �g _ �`�" x3 � Also; confirm that the,switch body hat notR, N been damaged in transit. It should not be bent. ,f If.the relay pin has become disengaged during transit or installation,follow the reset procedure outlined on Main 19.Page 9 � � �z . Gas Line . It the relav pin becomes disengaged during Gas Supply Inlet r PP y normal operation. ®O NOT attempt to re-install the pin. Turn off the gas suppIy and cal/your Figure 34 The gas supply line connects to the inlet to local dealer for-assistance. the left of the,control valve. 16 Operation Gas Control Knob Regulator- Piezo Ignitor Your First Fire u Read these instructions carefully and familiarize CD w yourself with the burner controls shown in Figs.35 ® \ and 36. Locate the Pilot assembly, Fig.37. Follow CD o '- the lighting instructions on Page 17 exactly. d T ®_ ]®IPA During the first fire, it is not unusual to smell some odor associated with new logs, paint and metal f;LL�kl being heated. Odors should dissipate within an hour or so, however,you can open a window to provide fresh air to alleviate the condition. Figure 36. Valve Controls and Ignitor. ACAUTION If the entire burner is not lit within —1 five (5) seconds of turning the switch ON, immediately push the switch OFF. Allow 5.minutes for gas to dissipate and repeat from Step 5. If"unsuccessful again, completely t�b turn off all gas to the heater and call your local gas service technician. Pilot and Burner Inspection Each time you light your heater check that the pilot . Pilot_ flame and burner flame pattern are as shown in Fig. fl 37 or Fig.38. If flame patterns are incorrect, turn the heater off. Contact your dealer or a qualified gas technician for assistance. Do not operate the heater until the pilot flame is correct. Follow regular maintenance procedures as Electrode described on Page 18. Figure 37. Pilot Assembly location and flame pattern. 3-Way Switch Settings ON: Continuous burning. OFF: Gas is shut off. T'STAT: Gas flow to burner is controlled by external thermostat setting. c� Figure 35. 3-way Control Switch Figure 38. Correct burner flame pattern. 77 FOFi YOUR.:SAFETY READ BEFORE LIGHTING. . WARNING: IF.'YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY,AFIRE OR EXPLOSION: MAY RESULT CAUSING ,PROPERTY DAMAGE, PERSONAL INJURY,OR LOSS OF LIFE: A: This appliance has a pilot. When lighting.the,pilot,follow these instructions exactly; B. BEFORE OPERATING smell all around the.appliance area for gas. 13e sure to smell next to the floor because some gas is heavier than air and will settle On the floor. WHAT TO DO IF YOU SMELL GAS Do notary to light any gas appliance. Do not touch any electric switch do not use any phone in your building. * Immediately call your,gas supplier-from a neighbor''s phone. Follow the gas supplier's instruc- tions. • If you cannot reach your gas supplier,call the fire department. C. Use only your,hand to turn the gas control knob. Never use tools. If the knob will not turn by hand, don't try to repair..it. Call a qualified service technician: Force or attempted repair may result in a fire or explosion. D:.Do not use this appliance if any part has been under water., Immediately call a.qualified service technician to inspect the appliance and to replace any part of the control system and any gas- control that has been under.water. LIGHTING INSTRUCTIONS 1. STOP! Read the safety information above on this label. ® o Z 2. Turn off all electric.power to the appliance. 3. Turn the thermostat to the lowest setting,(if applicable). �. Knoboi 4. Place the OFF/ON/T'STAT switch in the OFF position. Q 5. Push in gas control knob slightly and turn clockwise&to "OFF. NOTE: Knob cannot be turned from"' "OFF" unless knob is pushed,in slightly. Do not"force. 6. Wait five(5)minutes to clear out any'gas. If you then smell gas,STOP! Follow"B in the safety information above on this label. If you don't smell gas,got o the next step. 7. Turn knob on gas control counterclockwise to "PILO ." -8. Find pilot.The pilot is located below the logset in the forward.,lower right area of.the firebox. 9. Push in control knob all the way and hold in. Immediately light the pilot by pushing.the red ignitor button. Continue to hold the control knob in for about one(1)minute after.the pilot is,lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out;repeat steps through, . • If knob does not pop up when yeleased,stop and immediately call your service technician:or gas supplier. • If the pilot will notstay lit after several tries,rturn the gas control knob to "-OFF" and call your service.technician or gas supplier. 10. Turn gas control knob counterclockwise to "ON." 11. Place.the OFF/ON/T'STAT switch in the ON or T'STATposition. Pilot Assembly., 12.Turn on all electric power to the appliance. TO'TURN.OFF`GAS TO APPLIANCE' 1: Turn off all electric power to the appliance'if service-is to be performed. 2. Push in gas control knob slightly and turn clockwise,& to "OFF." NOTE: .Knob cannot be turned from "PILOT"to "OFF" unless knob is pushed in slightly. Do not force. 18 Maintenance 5 1 7 Your DV25 Gas Heater,will provide years of service with 9 minimal upkeep.The following procedures will,'help k :", t I{ __g r r ensure that your stove continues to function properly, l� l� 4 Annual:System Inspection s _...�� Have the entire heater and venting system inspected` I.Y ,:. .annually by a qualified gas'techn!clan. Replace any worn 12 g ;; 2 6 r 10 or broken parts. '- Logset and Burner/Cleaning and o Inspection. Cleanliness is critical to the proper function of the heater. The log set and burner must all be kept free of dust and unobstructed by debris. Inspect these areas before each Figure 39. Remove the glass frame screws in an use and•elean as necessary. alternating pattern. i. Turn the burner OFF and let the heater cool com- pletely before cleaning. .' Care;of Cast Iron. I` 2. Remove the Top plate. � ' I 3. Lift the Front Plate up and then swing the bottom out An occasional dusting•with a dry rag will help keep the to disengage it from the heater shell. painted surfaces looking new. Use high-temperature (' stove'paints, available through your local dealer,to 4.The glass panel and.frame'mustbe removed to gain touch=up areas as needed. Clean areas to be painted access to the firebox and log set. with a wire brush and be sure to cover the Logset, Burner • Use a Phillips`screwdriver to.first alternately loosen and and Valve assembly.Apply the paint sparingly; two light then remove the twelve screws that hold the glass frame coats of paint will give better results than a single heavy to the stove. Follow the pattern shown in Flg. coat. 39. Uneven pressure can break the.glass. WARNING A • Carefully remove the glass and frame assembly and place it out of the way on a flat, padded surface'such .TURN THE PILOT OFF BEFORE PAINTING as a counter protected by a towel. Disengage the side' ALLOWTHE HEATER TO COOL COMPLETELY clips to remove the screen from the Firebox. BEFORE PAINTING. S. Carefully inspect the Logset for damage. Contact your local dealer if any damage is evident. DO NOT Porcelain enamel surfaces should be cleaned with a OPERATE THE HEATER WITH A DAMAGED soft, damp cloth. Do not use abrasive cleaning agents. If, LOGSET. necessary, use only a cleaning agent formulated specifi- .. Use a soft bristled brush to sweep dust or debris from the cally for use on porcelain enamel surfaces. Logset, Pilot and Burner. Use care as the Logset is fragile and susceptible to damage. DO NOT USE A Cleaning the Glass VACUUM TO CLEAN THE LOGSET OR BURNER. Glass should be cleaned,only with a soft, damp cloth. Do 6. Replace the Glass panel and frame.Alternately tighten j not use abrasive cleaning agents. the screws In the same pattern as was followed in WARNING: Let the glass cool completely removing them. Do not use power tools, and do not before attempting to clean. over-tighten the screws.Over-tightening can break the glass. 7.Replace the Front and Top Plates. ; Glass Replacement Replace glass only with V:C.I. Part#1604691. See Fig 39. and previous,instructions for removal of the damaged glass panel. 19 Gasket Replacement The DV25,Gas Heater uses 5/16"rope-type fiberglass Switch Cable gaskets to seal between the glass panel and the firebox.,. In time, this gasket can become brittle,and;compressed and 'should be replaced. New gasket is available from , r d s',4k.J yil3R Y your dealer. Shut off the gas supply and allow the stove to cool. Wear;;safety goggles and a dust mask. is Remove the Front, Glass frame and'Glass Panel as .o 77, Remove the old gasket. Use a wire brush to clean the - I channel of any remaining cement or bits of gasket. ' Push Use a cold chisel if necessary, lever all the way I: 2. Determine the correct length of gasket by laying it out back Relay Pin in the channel. Allow an extra 1-2".'(25-50 mm), and toward` mark the spot to be.cuf. Use a utility knife.'Twist the the rear . . � p y the stove. • ends slightly to prevent unraveling. 3. 'Lay,an unbroken 1/8"(3 mm)bead of gasket cement Figure 40: Reset the relay,pin into the Safety Switch. in the channel. Starting at'one.end, press the gasket into thechannel. Ensure a good joint where the gasket ends meet before trimming excess. Do not overlap the pap y �x gasket:ends or leave ends with ragged edges. t F v 4. Press the glass frame firmly against the gasket to seat x '8V it evenly in its channel. 5. Clean excess cement from around the channel.Allow - rf$�` the cement to dry for at least,24 hours before:using your stove, T'i'; t Safety Switch box is bent Safety Switch. The DV25 heater is equipped with a safety,switch which Figure 40a,�Check that the switch box is not bent and will prevent burner operation if the relay pin becomes that nothing can interfere with the release pin. disengaged from its normal position for any reason. Normally-set, the-pin will be engaged with the switch , .through the hole in the top of the switch box. Safety Switch Relay Pin If the relay pin has become disengaged during transit orinstallation,.follow the reset procedure outlined below. i Confirm thaNthe switch box has not been bent and that the release pin and cable are free to.move: It the relay pin becomes d[sengaged during normal operation. DO NOT attempt to re-install #x`bxw 3i the pin.'Turn off the gas supply and call your local dealer-for assistance It is important togs � eaM deternnine what condition caused the Ain to be removed. 1..Push the switch lever fully back as shown in Fig.40 Switch Cable Heat Exchanger Door and insert the cotter pin/cable all the.way,through�the top and bottom of the switch box.The pin'must hold the lever back to engage the switch mechanism. Figure 40b. Switch Cable Position. 2. Be sure that the switch cable is'slack and positioned i over the top of the Heat Exchanger Door as in Fig. 40b. 20 Burner Adjustment An air shutter, located on the burner, has been set at the ° I� factory for either Propane or Natural gas and should not ° requite further'adjustment. Installation characteristics vary, however, and adjustment may be necessary to improve flame picture or eliminate sooting. Generally, the shutter should be set open 5/16"for Natural gas and 7/ 16"open for Propane. Closing the shutter, (less air), produces a yellow flame, (more prone to sooting). Opening the shutter, (more air), produces a bluer flame. After adjusting the shutter, the stove should be burned for at least one hour to see the effect of the setting change. If soot appears on the glass, logset, or firebox, Figure 41. Remove the burner retainer screws. the air shutter must be opened to eliminate the condition. Adjustment should be made only by a qualified gas technician. Step'l. Shut off the gas supply to thestove.Turn off all power to the stove. Remove the Front Panel,Glass,and Log. Set as described on Page 18 of the Owner's Guide. For Natural Gas +' Step 2. Remove the two Burner retainer screws. Lifting 5/16" I the back of the Burner, slide it to the rear and lift it out of I the firebox to access the air shutter on the end of the J tube. Fig. 41. Step 3. Loosen the shutter locking screw enough to adjust the setting as needed and re-tighten. Fig. 42. For Propane 7/16" Step 4. Set the burner back into the firebox taking care to ensure that the end of the J-tube fully engages and aligns with the injector, Fig. 43. Figure 42. Air Shutter Settings. Step 5. Replace the retainer screws,.log set, glass, and Front Panel. 0 0 0 0 0 o o 0 / o O O O O O O O 0 J-tube Injector C , /O O I Figure 43. Align the J-tube with the injector. 21 Parts List DV25 FIREBOX #2642(NG)AND #2643 (LP) 1. Firebox Assembly/NG 000-2642 14. Washer,Wingbolt 120-2470 Firebox Assembly/LP 000-2643 15. ;Washer 120-2474 2. RearShroud 500-2968 16. Fender Washer 120 2527 3. Top Cover,Shroud 140-8881 17. 1/4-20Wingbolt 120-3110 4. End,Left 130-1085' 18. Snap Ring 120-1987 5. End,Right 130-1086 19. Levelling Bolt 120-1745 6. Top Plate 13071102, 20. Glass 160-1691 7. Front Plate 130-1084 21. Gas Log Set 500-2964 8. Hinge,Control Door 160-1670 22. Door,Heat Exchanger 130-1095 9. Control Door 130-1087 23. Air Passage 130-1097 10. Top Heat Shield 140-8868 24. Firebox Baffle 130-1099 11. Tab,Steel 160-1488 25. Firebox 130-1100 12. 1/4-20x3/6'PhillipsScrew 120-0993 26. Flue Outlet 130-1101 13. 1/4-20x1/2'Hex Head Screw 120-1338 27. Gasket,Flue Pipe 120-3686 28. Flue Restrictor Plate 140-8869 29. Gasket,Glass Panel 700-0909 o ze 30. Frame,Glass Panel 140-8865 31. 'Bottom Heat Shield 140-8822 27 32. Safety Switch Assy 11 500-3000 33. OFF/ON Switch 160-1597 34. Gasket,Heat Exchanger 120-3689 6 35. Gasket,Firebox 120-3588 I i 10 14 3 17 ° 33 _ 12 i 34 22 15 dZ1 26 / 20 2919 I. ° (12) 12 O 17 25 - 30 ) 14 _21 �� :•. i_G 8). 16 13 22 % �.L (19 (_e) l� For replacement parts,or for information about parts or service,contact your local dealer. For the name of the dealer nearest you,call or write: The Majestic Products Corp. 1000 E.Market St. Figure 44.1llustratedParts Huntington, In.46750-2579 1-80.0-227-8683 f I I 22 Wiring Diagrams Figure 45. DV25 Firebox Circuit Figure 46 DV25/Convection Fan Circuit T'STAT OFF ON POWER CORD qFAN 1,4dTERLOCK TH/TP RED ' RED FAN JUNCTION BOX J Q r r TP O W , m I I F- WHT ,BLK ' F ; THERMOSTAT elk TH / ' W 2 Chassis GRN WHT BILK ,GAS VALVE Ground BLACK t --------------- {' NOTE: IF ANY OF THE ORIGINAL,WIRE,AS Strain Relief SUPPLIED WITH THE APPLIANCE;MUST.BE oNjOFF REPLACED, IT MUST BE REPLACED WITH Rheostat TYPE SF=2, 200°C WIRE,OR ITS EQUIVALENT. ' Snapstat WHT' GRN i-------� Chassis Ground RHEOSTAT/SNAPSTAT BOX CONNECTION DIAGRAM FIELD.WIRING Screw 120 VAC Identification Chart BLK" GGRN BL MOTOR BLK \J 1^ ON/OFF RHEOSTAT - - - _ _ SNAPSTAT 5/81' . -- -t BLK t 3/V I t WHT � GRN _ ; Phillips#10 Phillips Philiip's#10 Phillips SCHEMATIC DIAGRAM sheet metal 1/4-20 sheet metal 1/4-20 Figure 47. l 23 Appendix A Figure 48. Venting Terminal Clearances Mill 111111 t 13 G G \ A1� Key F,I 9"U.S.only A,B,C,E,F,I,j 12"/30cni - D 18"/46cm H,L 3'/90cn G,M 671.8m A. Clearance to a non-mechanical air supply inlet or combustion air inlet of any other appliance. B. Clearance under a deck,porch,veranda or balcony. Must be fully open on a minimum of two sides beneath the floor. C. Clearance above grade,deck, porch,veranda or balcony. D. Clearance,to a ventilated soffit located above the terminal within a horizontal distance of 2 feet (60 cm) from the center line of the terminal. E. Clearance to an adjacent wall (inside corner). F. Clearance to a permanently closed window. i G. Clearance around a service regulator vent outlet. 1-1. Clearance around a center line above service regulator. 1. Clearance to a door or window that may be opened. J. Clearance to a non-ventilated soffit. K. Clearance above a paved sidewalk or driveway on public property. May not terminate above a sidewalk or driveway which is between two single-family dwellings and serves both dwellings. L Clearance to vegetation. M. Clearance to a mechanical air supply. Note:All clearances as specified in(lie National Fuel Gas Code,1992 and CAN I BI-149 Installation Codes. Local codes'or regulations may require more stringent clearances. 24 Troubleshooting Follow these procedures in the order presented. ® WARNING " TURN OFF HEATER AND ALLOW TO COOL COMPLETELY BEFORE SERVICING.- ' CONDITION POSSIBLE CAUSE SOLUTION No spark at pilot when 1. Ignition Electrode is discon- 1. Inspect and re-connect, Ignitor button Is pressed. necte.d from ignition wire, replace or repair as necessary. broken, or incorrectly posi- tioned. 2. Piezo Ignitor nut is loose. 2. Tighten the nut to establish secure contact to the valve bracket. See Fig. 48. 3. Bad Piezo Ignitor:. 3. Replace Piezo Ignitor. j' Thermopile Thermocouple -Pilot hood Igniter The Ignitor Electrode 1. Gas supply is turned.off or 1. Turn on gas supply or open sparks,but Pilot does not " supply line shut-off valve is supply line shut-off valve. Ilght. closed'. ; 2. Control Knob is'not in PILOT 2. Turn Control,Knob to PILOT. position. 3. Control Knob not pressed in 3. Press Control Knob in while in:' while in PILOT position. the PILOT position. 4. Air present in gas lines. .. .4. Continue holding in-Control Knob and repeat ignition procedure until air is bled from '. the lines. 5. Inlet supply pressure is not 5. Call local gas'supplier.Adjust l inlet supply pressure to specifi- within correct settings: cation: Natural Gas: 5°W.C. - 11•W.C. Propane: 11.0- 6. Other conditions'that should 13.0'W.C. be identified only by a quali- 6. Call qualified"gas technician. fied gas technician. . I F egu ator Piezo Ignitor Figure 48. DV25 Control � _ g " Valve Assembly., Thermostat or On/Off/ z Tstat switch wires(top 'Gas Line from supply_= \ and bottom terminals) o 0g® . Control Knob —Thermocouple wires (middle and bottom. terminals) Gas Line to Pilot Control Valve Body 25 CONDITION POSSIBLE CAUSE SOLUTION Pilot lights but flame goes 1. Control Knob not fully de- 1. Depress Control Knob fully out when Control Knob is pressed or held in long and hold in for a full 30 released. enough. seconds. 2. Gas supply line shut-off valve 2. Fully open gas supply line is not fully open. shut-off valve. 3. Thermocouple connection is loose at the Control Valve. See 3. Inspect and tighten securely. Fig. 48. 4. Pilot flame does not touch the 4. A) Contact the local gas Thermocouple. Fig. 49. This company. Inlet supply pres- can be caused by: A) Incor- sure should be between 5" Thermocouple rect gas pressure, and/or W.C. and 11 W.C. for NG or B) other conditions that should 11" W.C.- 13" W.C, for LP. Pilot flame Is weak-does not be identified only by a qualk Adjust as necessary. touch Thermocouple. fled service technician. B) Call local gas service Figure 49. Incorrect Pilot Flame technician. 5. Thermocouple is damaged. 5. Call local gas service techni- cian. 6. Control Valve is damaged. 6. Call local gas service techni- cian. Figure 50. Correct.pilot flame. Pilot lights but Main Burner 1..Gas supply line shut-off valve 1. Fully open gas supply line does not. is not fully open. shut-off valve. 2. Foreign material is blocking 2. Inspect and clear debris Burner ports. away from Burner ports. 3. Main Burner orifice is clogged. 3. Call local gas service techni- cian. 1 4. If unit is wired to a thermostat, 4. Turn On/Off/T-stat switch to the thermostat is not calling for 'On", or turn up thermostat. i heat. Main Burner shuts off and 1.Incorrect inlet supply pressure. 1. Contact the local gas com- Pilot flame goes out while pany. Inlet supply pressure In operation. should be between 5" W.C. and 11"W.C. for NG or 11" ' W.C.- 13" W.C. for LP. Adjust as necessary.