Loading...
HomeMy WebLinkAbout32518-Z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-32054 Date: 12/05/06 THIS CERTIFIES that the building ADDITION & ALTERATION Location of Property: 11085 SOUNDVIEW AVE SOUTHOLD (HOUSE NO.) (STREET) (HAMLET) County Tax Map No. 473889 Section 54 Block 5 Lot 38 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated NOVEMBER 27, 2006 pursuant to which Building Permit No. 32518-Z dated NOVEMBER 28, 2006 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ADDITIONS & ALTERATIONS TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR. The certificate is issued to VINCENT F CARNAGIE (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A ELECTRICAL CERTIFICATE NO. 04-0793 03/21/04 PLUMBERS CERTIFICATION DATED N/A Authorized Signature Rev. 1/81 Form No.6 TOWN OF SOUTHOLD - " BUILDING DEPARTMENT TOWN HALL 765-1802 �fi2 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. ,57 Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. 7 C. Fees ��� 1. Certificate of Occupancy-New dwelling$25.00,Adr!fitions to dwelling$25.00, Alterations to dwelling$25.00, Swimming pool$25.00,Accessory building$25.00,Additions to accessory building$25.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00 S GIZ7�?J T/0W Date. JZNew Construction: Old or Pre-existing Building: (check one) Location of Property: /6 — House No. Street Hamlet Owner or Owners of Property: Vj,V&X41T CA lz tye / Suffolk County Tax Map No 1000, Section `j Block C'_ Lot Subdivision Filed Map. Lot: .3�51 Permit No. Date of Permit. 7 Z o/ Applicant: iS d ti N Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ Applican ature �1IfS.S FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 32518 Z Date NOVEMBER 28, 2006 Permission is hereby granted to: VINCENT F CARNAGIE 11085 SOUNDVIEW AVE SOUTHOLD,NY 11971 for CONSTRUCTION OF ADDITIONS & ALTERATIONS TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR.REPLACES BP # 29923 at premises located at 11085 SOUNDVIEW AVE SOUTHOLD County Tax Map No. 473889 Section 054 Block 0005 Lot No. 038 pursuant to application dated NOVEMBER 27, 2006 and approved by the Building Inspector to expire on MAY 28 , 2008 . Fee $ 195 . 00 Authorized Signature ORIGINAL Rev. 5/8/02 1. ELECTRICAL INSPECTORS, INC. is not responsible for the existing conditions at the subject premises. 2. ELECTRICAL INSPECTORS, INC. is not responsible for corrections, upgrading or replacement of existing electrical violations at the subject premises. Any corrective work shall be solely the responsibility of the property owner. ELECTRICAL INSPECTORS, INC. DOES NOT WARRANTY OR UNDERWRITE THE ELECTRICAL CONDITIONS AT HE PREMISES. 3. ELECTRICAL INSPECTORS, INC. only recognizes the rational Electrical Cade, the Blew York State Building Construction Codes and Local Municipal Codes. 4, AN ELECTRICAL SURVEY consists of a visual examination of the premises ONLY: Electrical Inspectors Inc. will comply with the requirements of NFPA 73, latest edition Chapter 1, Section 1-1, 1-2. If violations exist, a Notice of Violation (NOV)will be issued requiring correction by a licensed electrical contractor. After the violation has been corrected, a re-inspection will be conducted and if approved a certificate shall be issued. 5. A SURVEY CERTIFICATE does not examine the actual wiring or devices unless all walls are opened and wires and devices are exposed prior to the survey being conducted. 6. A CERTIFICATE IFICAT is non-transferable. 7, AN ELECTRICAL INSPECTION consists of an examination of wiring and installations during the rough stages of construction. After completion of the construction a final inspection will be conducted at which time a certificate will be issued provided no violation exist. In the event no inspection is requested during the rough stages of construction ELECTRICAL INSPECTORS,S, INC.will perform a CLOSED WALL SURVEY that consists of a visual inspection of the wiring and installations only. Since access is limited, ELECTRICAL INSPECTORS, INC. shall bear no responsibility for any defects or violations at the premises. 8. ELECTRICAL INSPECTORS, INC. shall not be responsible to remove any walls in order to conduct an electrical inspection. 9. ELECTRICAL INSPECTORS, INC.will only release information, certificates and reports to the applicant after payment for services rendered have been paid in full. 10. ELECTRICAL INSPECTORS, INC. assumes no liability for the results of its inspections. 11. The agreement may not be changed orally. Town Hall,53o95 Ma;r Road P.Q. Box 1179 Go �e Southold, Phew York 11.971 py Fax(616)765-1823 �' Telephone(616)765-1802 OFFICE OF THE BUILDING INSPECTOR TOWN OF SOUTHOLD C E R T I F I C A T I O N Euilding Permit No. 2-�� 23- Owner: n -" Ca rn � (please print) Pltlilibez': Gilliam M. Gremler (please print) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. �ZU Signature) Sworn to before me this c�AJ day of Notary Public, ounty ELAINE T.VILLANO Notary Public,State of New York No.01VI6029229.Suffolk Count�f,, ()®mmisslon Expires Aug.9, v r ilia 31 MAP OF LAND wLCrR Plow -- �Iss zANOt M. C�QNAGI�: Pool . ;NEAP . . SCALC: sVa 0 r4 te No, S- 177027' _ y• �sa�'T.�+aS�'Vc x`.�`y' 4i._ � Li�t�, •�: _' _ - i _ •. -�••. - �' _ _ -. ' •i• '. i��rta � ..ti• -. .. • - � a _.5 as _ ` , --•� ,' .?_ Q.i _ ��. ti. _ :fir• - _ •' -_ _ _ � �� = s:-_' •_ Y�t�tlt1fiC�'�+OtE1e1� • .►L. r y cr-- .•Y,r:y12.Via•.`" a � "._• .•�-'.- i �ild $A®r49 fie v(� aSt�t' etq VIE RX �t'�f1.tb�t W. ie ray. - tea..{`.��y. - •.l - may._. -_ !''t, •".- •.tom. _ - _ �•�C'i'� -r1 A 'tom 'iEyry.�7.:••• :s` -.�'� .'�..,`�+:-:- -.4 -(ti.:^i_ .�l.r. - .s�.:y. �-L ,_9- Y'!::-' .J. �.- _ � -°�•: y _Ya .dam } �}r•/r:: - +l. - -41.' '..lY. .� .p..l� •-�,i.= •°..� Y�• d /►i • •='T,+- -i _ .ri ,�{r,�� �`e�.w•. ,y3�-•,�'+..�.•"�.':°-+1 {'' �..' r-v:'.Z. :a. :'ii. -mow'-' - ..r.�:' .•Y.. - `�__ . i_- '1 .i�' _ --.^�=t•t. 4�-1.•s.�.s:�' � -{-'�'9."'f�_r.�✓:`- ..•S ��.-:f--.!� �_s�f,��'Yc+. j �... _ : --k'.• � _.. _ _ -: s- . �:r ,`�; - -- -.icy. _ �.,z.�- ;;;- ��GCt� .b�''t�• ^'- :{�.- .;�. TOWN . OF SOUTHOLD PROPERTY,; RECORD CARD � OWNER STREET' // VILLAGE DIST. SUB. LOT r'��?�G�'t�� �V• G �� ;�', ��/'� ,�i; _-�J'�( tom . FORMER OWNER N E ACR. S W TYPE OF BUILDING RES. ,7"/ IEA VL. FARM COMM. CB. MISC. Mkt. Value LAND IMP. TOTAL DATE REMARKS d Dji �C> 3 7e,D ® FJ I �ul� tb V4L"t� �Z y o z o -LI zz Goo Arta!q!e JDC��Ie�1 a 5 OcAGE B �j c.NG C ND N NEW NORMAL BELOW ABOVE 1-i—(o� ��• J sal FARM Acre Value Per Value Acre Tillable 1 Tillable 2 Tillable 3 Woodland Swampland FR&N�IGE ON WATER Brushland FRONTAGE ON ROAD r House Plot DEPTH Z p BULKHEAD Total DOCK OF OMEN ■■■■■ ®■■E■■■■■■■■■■■■■■■ �■■■■■ ■ K-SA ;■fl■■■■■NNi■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■ :. Dinette c .. . ® •sement .. CONSPECT ENGINEERING P.O. Box 162 Pearl River,New York 10965 845-300-0707 November 17,2006 Town of Southold Building Department Southold NY 11971 To Whom It May Concern: All snow load and stud strapping at the Carnegie job Permit# 29923-Z meet New York State code. All other changes to plan were inspected by Southold Town inspector and are not structural changes. E. ev � r Sanford Lent P.E. CONSPECT ENGINEERING,P.C. P.O.Box 162 cs'FA Pearl River,N.Y. 10965 845-300-0707 Tn�L` °<^•� sou ",�.% Town of S hold Building Department Southold NY 11971 To Whom It May Concern, All snow load and stud strapping at the Carnegie job Permit#29923-Z to meet New York -State=code . All-other-changes-too-plan=were-inspected=by-Southold Town inspector arid- are not structural changes E N£{y SPA �•"f�'� c SA EN �?FO 046732 pF SO�IyO�o TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION REMARKS: _ DATE INSPECTOR FL ,65.1802 BUILDING DEFT. INSPECTION [ ] FOUNDATION 1ST XRGH LBG. FOUNDATION2ND ON [ ] FRAMING [ ] FINAL [ ] FIREPLA CHIMNEY REMARKS: DATE INSPECT 765.1 soa BUILDING DEPT. INSPECTION [ ] FOUNDATION 7ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ FRAMING FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION REMARKS: ( c'm u oz C-m ot- DATE � _ �� �s INSPECTOR ' ��� ass-isoi BUILDING DEFT. INSPECTIO [ ] FOUNDATION iST [ ROUGH PLBG. [ ] FO ATION 2ND [ ] INSULATION [ FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY REMARKS: J /"_ptdu.. DATE INSPECTOR 765-1802 BUILDING DEFT. NSPECTION [ ] O DATION iST [ ] ROUGH PLBG. FOUNDATION 2ND [ ] INSULATION [ ] FRAMING [ ] FINAL [ ) FIREPLACE 8 CHIMNEY n EM RKS• � V� 16A-�-e DATE / /v ��INSPECTOR . � IIIP- WV- ✓i ----_--._--.,--____..__. i WIff, lift will J • - TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMNIENT Do you-have or need the following,before applying? TOWN HALL ' Board of Health SOUTHOLD,NY 11971 3 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey www.northfork.net/Southold/ PERMIT NO. Check Septic Form N.Y.S.D.E.C. f2 Trustees Examined ,20 Contact: Approved 1 t Y ,20 Mail to: Disapproved a/c / Phone: Expiration ,20 j7— Building Inspector i APPLICATION FOR BUILDING PERMIT y ?nn? Date 520 INSTRUCTIONS -— —a:-This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans, accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applican or name,if a corporation) (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder C07'L7AACla- Z- Name of owner of premises (As on the tax rolIC4 latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Locatiorj�f land on which proposed work will be alone: �+ House Number Street Hamlet County Tax Map No. 1000 Section sY Block 5 Lot 3 Subdivision Filed,Nlap No; ' ' Lot (Name) 2. State existing use and occupancy of premises and intended use a occu ancy of ro osed construction: e a. Existing use and occupancy c�� ✓ G b. Intended use and occupancy. 3. Nature`of work(check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work (Description) 4. Estimated Cost ��Doo Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars k-111f business, commercial or mixed occupancy, specify-mature and extent of each type of use. FDimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front ', n Rear -20 Depth 7 5 Height -,:7/4.-✓ Number of Stories ! 9. Size of lot: Front Rear C' Depth 5 O 10. Date of Purchase Name of Former Owner 11 Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded?YES O Will excess fill be removed from premises? YES NO le 14.Names of Owner of premises y i�Ce•✓T ddress Phone No. Name of Architect Address Phone No Name of Contractor /�r,/� iz(� Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES O * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS M4X BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES O * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. STATE OF NEW YORK) SS: COUN 71r-Y­ being duly sworn, deposes and says that(s)he is the applicant m o in 'v' a 'gning contract)above named, (S)He is the tractor, Ag orate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to b fore me thi ay,of 20 O 71L�"n=7� Notary Public VgnYure of Applicant BARBARA ANN RUDDER Notary Public,State of New York No.4856805 Qualified In Suffolk County Commission Expires April 14, PENNY LUMBER 681 477 057e 12/08/08 08as2pm F .- tatac. ENERGY CODE.CALCULATIONS CHAPTERS SECTION 501. Detached One and Two Family Design Criteria 5750 Degree Days (For Non-Electric Heat) Zone 11B 6qjI.1�1 e 1 Per: Peh h "" p� �ZqV For: —T �— �,j D J i -j Dated: p° 1i I ty DESIGN CODE DESIGN` CODE SUBSYSTEM AREA ��,, CCU95 UA UA Exterior Walls j 0 v Q. / 0 n3. .0.14 SD . 7 • 0 a i Ceiling Roof d Q 0 3 0..0.31 . 1,3_ y'jj Floor over i7nheated:Space (� ;.D 0.05 Z 3..3.v 2 3.3 D. � .. - Heated Slab On Grade 6.5 Unheated Slab On.Grade 4.5 Basement-Wall 0.1: Crawl Space Wall 0.06 NOTES: Construction shan.comply with 502.1:1 moisture control and 502.1.4 air lealrage . •Buildung Envelope Systems to meet requirements.of Section 501 The mechanical systems and equipment including: HVAC Equipment,HVAC Systems,Duct Systems,Ventilation Systems and Insulation.of Piping Systems to meet requirements of Section 503 Service Water Heating Systems&Equipment to meet requirements of Section 504 Electrical&Lighting Systems&Equipment to meet requirements of Section 505 To the best of my knowledge, CA . { belief, &professional judgement, 4 . 254-` c�z2�a 1 a, these plans are in compliance with,the code: PENNY LUMBER. 631 477 0s78 12/08/0.9 08:szpm r, iaiaz. ENERGY CODE.CAI;CUi,ATIONS ( CHAPTER,S SECTION 501. Detached One and Two Family Design Criteria. 5750 Degree Days (For Non-Electric Heat) Zox a 11B 0 4Yh e / Per:_/"r� h �n Z,91 42 A/ For: c T puh � w Aye, Dated DESIGN CODE DESIGN` CODE SUBSYSTEM AREA. �„ C�„ UA UA Exterior Walls D 0 G- /0 0. .0.14 SD . �J. .7 U O D Cell' Roof 0.031 Floor Over LTnheated:Space: 1� v D O.os v' 3 U. d . . . 23 3 2.3� Heated Slab On Grade 6.5 Unheated Slab On.Grade 4.5. Bawment.Wali 0.1 Ciawl Space Wall 0.06 -NOTES:. Construction shall comply with 502.1:1 moisture control and 502.1.4 air leakage . .$uilding Envelope Systems.to meet requirements.of Section 501 The mechanical systems and equipment including:. HVAC Equipment,HVAC Systems,Duct Systems,Ventilation'Systems and Insdlation.of Piping Systems to meet requirements of Section 503 Service Water Heating Systems&Equipment to meet requirements of Section 504 Electrical&Lighting Systems&Equipment to meet requirements of Section 505 or- NFW f• fS '�`'� �'•'''r ' Ali 6! To the best of my I�iowledge, ":a 6it W belief, &professional.judgement, ? � 2 ( � 432�5A 1 these plans are in compliance �'•� o� , with the code. " BUILDING PERMIT EXAMINER CHECKLIST DATE REVIEWED: /Z /,Y /03 APPLICANT: y2�'�tJU DATE SUBMITTED: �/ /03 SCTM#DISTRICT: 1,000, SECTION: , BLOCK: _ 7 LOT: c38 SUBDIVISION: ADDRESS: //D�� .��f y � CITY: oont/d Cif ZONING DISTRICT: CONFORMING?/k/o BUILDING PERMITS OPEN/EXPIRED: PRE CO�R N 15 sclL BP -Z/C/O Z- 15544, , INFO FI/�)b /BP I,�_-Z/C/0 Z-c' -, INFO ,A ci�2_ BP -Z/C/0 Z- , INFO /BP -Z/C/0 Z- , INFO SINGLE & SEPARATE CERTIFICATION-REQUIRED NOTES: LOTS 40,000SF-100-24.Lot recognition.(CREATED before June 30,1983),UNDERSIZED LOTS FROM JAN.1997 100-25.Merger.(A nonconforming at any time after 7i REQ. LOT SIZE: ACT. LOT SIZE2 U5 REQ. LOT COV. UPz� ACT. LOT COV. REQ. FRONT PROP. FRONT t i REQ SIDE ACT. SIDE REQ. REAR PROP. REAR r REQ. HEIGHT PROP. HEIGHT PROJECT DESCRIPTION: ESTIMATED PROJECT COST: ARCHITECTGINEER: WATER FRONT? V DESCRIPTION: `` PANEL # FLOOD ZONE: X_ APPROVALS REQUIRED SUFFOLK COUNTY HEALTH D PT: YES orOO (BED #): DTE: /_/_ PERMIT#: TOWN SEPTIC RECEIPT: Y oru NEW YORK STATE DEC: PRE-DEC 9/1/75 YES or(D DTE: /_/_ PERMIT#: SOUTHOLD TOWN TRUSTEES: YES or DTE __/ / PERMIT#: TOWN ZON11�NG BOARD APPROVAL: YES or DTE• /_/_ PERMIT#: TOWN PLC N. BOARD APPROVAL: YES or DTE / / PERMIT#: TOWN HISTORICAL PRE (SPLIA): YES or NEW YORK STATE CODE COMPLIANCE (SEE PAGE E or NO NOTES: FEE STRUCTURE: FOUNDATION: 06 SF FIRST FLOOR: 5-60 SF SECOND FLOOR: SF OTHER: SF INIT OTHER TOTAL TOTAL: SF FEE FEE FEE SF)- ( ;V SF)= SF X $ =$��-+$ i a +$ _$ s 2. ( SF)- ( SF)= SF X $ _$ +$ +$ _$ 3. ( SF)- (SF)= SF X $ =$ +$ +$ _$ FINAL TOTAL: $ (� NEW YORK STATE CODE COMPLIANCE CHECKLIST CLIMATIC/GEOGRAPHIC DESIGN CRITERIA: Ground Snow Load: 45 Wind,Speed: 120MPH Seismic Design Category:B Weathering: Severe Frost Depth: 36" Termite: M-H Decay: S-M Design Temp: 11 I�e'S ihih eld Underlay: YES Flood Hazards: USE/OCCUPANCY CLASSIFICATION: HEIGHT/FIRE AREA: TYPE OF CONSTRUCTION: DESIGN CRITERIA: ENGINEERF�D/P SCRII'TIUE (/ F FULL FRAMING DESIGN ELEMENTS:, /N HEADERS: Y/N WALL STUDS: Y/N GIRDERS: Y/N CEILING JOISTS: Y/N FLOOR JOISTS:Y/N ROOF RAFTERS:Y/N LUMBER SPECIES AND GRADE:Y/N DESIGN LOAD CALCULATIONS: Y/N LIVE: Y/N DEAD:Y/N SNOW:Y/N SEISMIC:Y/N WIND:Y/N WINDOW AND DOOR SCHEDULE: MISSLE TEST RE.. U MENTS: IIN EGRESS 5.7 5 .: '/N� LIGHT 8%:�Y.N r VENT 4%: Y/N NAILING/CONSTRUCTION SCHEDULE:IIN MEANS OF EGRESS: Y/N PLUMBING RISER DIAGRAM: LOCATION OF FIRE PROTECTION EQUIPMENT:-Y/N TRUSS DESIGN: Y/N CERTIFICATION: Y/N ENERGY CALLS: Y/N TOTAL COMPLIENCE? Y/N (RETURN TO PAGE ONE) . CERTIFICATION OF NAILING & CONNECTIONS �'1'/ BUILDING DEPARTMENT CRITERA 1 OCCUPANCY CLASSIFICATION R-3 RESIDENTIAL-SECTION 310 BUILDING CODE N.Y.S. USE DWELLING UNIT-SECTION 310-310.2 2 HEIGHT N/A FIRE AREA(sf) 500 NEW CONSTRUCTION 1 3 TYPE OF CONSTRUCTION WOOD FRAME CONSTRUCTION ! ! , 4 DESIGN CRITERIA PRESCRIPTIVE DESIGN-1995 WFCM HIGH WIND EDITION { I 5 FRAMING ELEMENTS SEE PLANS AND SECTIONS i 6 DESIGN LOAD CALCULATIONS PAGE 3 ! ! 7 WINDOW AND DOOR SCHEDULE PAGE 4 8 LOAD PATH SEE SECTION PAGE 2 ! i 9 NAILING SCHEDULE PAGE 3 10 EGRESS SEE FLOOR PLANS ;� 11 PLUMBING RISER DIAGRAM PAGE 4 II- ' 12 FIRE PROTECTION SEE PLANS PAGE 1 Z I O j j� 13 TRUSS DESIGN DRAWINGS N/A Z J u) f ;p 14 ENERGY CALCULATIONS ATTACHED I O ;Q • UNDERWRITERS CERTI FICATE zl REQUIRED 31 ,-3 ; Ww rY APPROVED AS NOTED A DATE: L21//� B.P a`i g2 3 a , 20' 20' FEE-1c — I I I FEE: `' BY: i I 10 10 NOTI Y BUILDING DEPARTMENT AT 765-1802 8 AM TO 4 PM FOR THE W t FOLLOWING INSPECTIONS: - 1—FOUNDATIO TWO REQUIRED ' FOR P�RE� CONCRETE I O I 3046 3046 W IW 1 CL 2. ROUGH � FRIAMING & PLUMBING I N —Z >; l -, 3. INSULATION NAL - 6ON�TRUCTION MUST �ry' Z'� 4. FI I I _ 8X16 PIER, (TYP.) '_ BE COMPL I Q<� ET E FOR C.O. (� 0 -� ALL CONSTRUCTION SHALL MEET THE !REQUIREMENTS' OF THE CODES OF NEW „ � NEW BASEMENT YORK STATE. NOT ZIP COLUMN ON 2-0 X = S/D RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. iV 2'-0"X V-0"P.C. iv iv FOOTING, (TYP.) .- . 11 _ iv � - C-OmpL-Y- ITH ALL CODES OF � � 8 8 FAMILY ROOM Ns YORK TA E & TOWN CODES p o A w S R QUIRE AND CONDITIONS OF a- E 9'-4" —F 9-4 W M w S01 OLD TOWN ZBA w rn N Z z N N ! vvlao 11 $„CJ- 16"oac - SIXTHOLD TOWN PLANNING BOARD 'CD � cMo Q � a r. 2x8 FJ=1 s°o�C _ / SC UTHOLD TOWN TRUSTEES �_� o _ � � N.�.S.DEC ¢ z � M ,- O o NN _o °s� °�� ALL COS RUCTION SHALL Z v 1 - _ - MEET THERE UIREMENTS OF THE - c i o CL aATHRooM CODES F EW YORK STATE. � (V '- 19 J �. BILCO DOOR PLU�BING N „ ALL PLUM ING WASTE rn bo 6 4„ VENT TO EXTERIOR WALL. °° 6r, x &WATER INES NEED 6'-6" _ 4' - — 8'-2" TESTING EF RE COVERING N . i �o�� PLUMB R CERTIFICATION ANTENT BEFORE cn CERTIFICATE OF OCCUPANCY w EXISTING HOUSE PROVIDE-ACCESS To SOLDER USED IN WATER z EXISTING BASEMENT SUPPLY SYSTEM CANNOT U EXCEED 2110 OF 1% LEAD. Z EXISTING BASEMENT — O FLOOD ZONE /� COMPLY WITH CHAP R "46" FLOOD DAMAGE PREVENTION zz SOUTHOLD TOWN-CODE. Q W R" G'32254-1 o�' OFESSI®�P�� FOUNDATION PLAN - FLOOR PLAN SCALE Y4' = 1'-0" SCALE Y4 1'-0" OCCUPANCY ORLb USE ISUNLAW FUL N , WITHOUT CERTIFICATE W Li OF OCCUPANCY � o I I � TORCH DOWN ROOF 1 4 ' / SHEATHING t 2X4 SLEEPERS @Y"PITCH I I 140 11 /a CJ- 16 O/C s 3 �� /a SHEATHING z; I 'w z M i t- ,. O p 2X6-16 O/C PLATFORM FRAMED STUD . t, .�; WALLS W/R-21 INSULATION ! _./ 10 I O ,. Q U ! LOAD PATH ri I Z of pa DETAIL B 1 SCALE /4 -011 ti I � L ; i ; - 10 ILL w ----- ----- — z ' Lo SEE DETAIL B � Q , i .,..�,. WI40 11 /s CJ- 16 0/C (n 4. �� --- ------------------- - O { FASTENER E 2X6 16 O/C PLATFORM FRAMED STUD � WALLS W/R-21 INSULATION FAMILY ROOMco _ -- co p Ln _ d o .� — - — - FASTENER E _ E ?f ►�"I z ti t (2)2X6 CCA SILL w SILL SEAL - -- _ M --- -- - TERMITE SHEILD 2X8 FJ- 16' O/C s ANCHOR BOLTS, / CB, 10 4'OC V FROM CORNER �= o NEW BAS ENT f O o GRADE Z ao r; -- $ POURED CONCRETE WALLS WITH WATER BARRIER AND 1-4 X 8 FOOTING (o (2) 1 /a X 9 Y LVL GIRDER - _� �— — — ZIP COLUMN ON 2-0 X 2 0 X 1 0 P.C. FOOTING r _ _ t , W r - z W U z Ll_ Z i WC G 0%E lh! I , a. c"9uj - e • _ J� 032254 SECTION A _.. oP9OFESS1 ! - SCALE 1/4" = 1'-0" U l , O o t _ N _ N 1 w I o C) 7 0 LO cc Q slots cn LU r- U. 6�' cc 7- cr w 19 7 9 Ir uj LU 032254-1 �NFE SO SO co cn STRUCTURAL WOOD PANELS FOR WIND—BORNE DEBRIS PROTECTION ( , S -------------- ,I p FOR WALL OPENING PROTECTION OF120 MPH 3-SECOND WIND GUSTS ' 4- MAXIMUM MEAN ROOF HEIGHT.35 j 'WINDOW AND DOOR SCHEDULE f ? t l a , lco N MULTIPLE SECT O ASSEMBLY. 1/4 i _., 1 THICK BOLTS @2,OG 3046 NAF2ROLINE 1 20 4 24.7 26.9 50 5-3 X 3-8 ZL!< _. ..I AN31 A1W NIINNG 10 4 25.9 28,1 30 2-3" X 3'-6" I!'r- � , C- !ALL WINDOWS TO BE ANDERSEN I + < o I :W CALCULATIONS FFOR WINDOWS BASED UPON EXPOSURE 8 ;MUST HAVE DP UPGRADE KIT. I iCOEFFICIENT 1.01 WITH 126 mph BASIC WIND SPEED. AS PER E ;MEETS NY STATE EGRESS REQUIREMENTS U IZ IW Iw ' LL __.__._ -._ _. x TABLE R 301.2 (2,) NEW 1�ORK STATE BUILDING CODE. i 1 yFOR HABITABLE SPACE.. 1 ! ', � y _ ;CUSTOM GRILLES - SEE ELEVATIONS ;tn I '< Z I iW ; i I Y I iWALL OPENINGS INCLUDING WINDOWS AND DOORS SHALL BE PROTECTED WITH REMOVEABLE 5/8"WOOD STRUCTURAL PANELS 1WITH MAXIMUM OF 8-0" SPAN. FASTENERS FOR SPANS UP TO 6'-0" S A B / - ` .-.. _ H LL E 2 1 2 # 8 WOOD SCREWS AT 16 O/C FASTENERS _ _ _ -. FOR SPANS UP 1T0 8'-0" SHALL BE 2 1/2" -#8 AT 12" O/C. TABLE 301.2.1.2 ' jALLNARROLINE WINDOWS MUST USE: 1!2 HEIGHT SILL.STOP (OR STOOL)AND .THE ADDITION OF A 1/2 X 3/4 DP UPGRADE SILL STOP. (SILL STOPS TOTAL A 1-1/4" + < i IRE H IN A I -N A P f (HEIGHT AND REDU THE ST LLATO OF S ECIAL SASH LIFT INCLUDED WITH DP UPGRADE SILL STOP KIT.) j I TALL UNITS MUST MEET OR EXCEED THE MINIMUM DESIGN PRESSURE REQUIRED,ANY MULLED UNITS MUST MEET O_ R EXCEED 71 z1.5 TIMES THE DIESIGN PRESSURE REQUIRED AND MUST TRANSFER LOADS TO THE ROUGH OPENING SUBSTRATE. ALL EXTERIOR I - ------ - '-, W I +GLAZING MUST NAEET ASTM E 1996 TEST REQUIREMENTS AS PER NEW YORK STATE RESIDENTIAL CONSTRUCTION CODE. I I IREFER TO SECTIION R 1609A.4 FOR ALTERNATIVE OPENING PROTECTION. i I O' r ' i I i , -i O — Z, O O: I I O Z. Q _ ' ice' �'� ~� ! • - Q'. 0! ' (p, Uco l 11 ,0 I` W 'CI W lTq" 0') co :SHUTTER ASSEMBLY - N.T.S. < \.: 4°0 ROOF VENT FOR PANEL SPANS: 0<4'-0"WIDE SPAN -- - p ROOF ,. �- � r TABLE 1609.1.4 Q Z 4 - - O . 6 ' ::23/32"APA SPAN-RATED 48/24 SHEATHING GRADE PLYWOOD(OVERLAP AROUND OPENINGS 4 ) ti r• _ Z ti ATTIC USE AC GRADE W/2 COATS EXTERIOR PAINT 2 SIDES,4 EDGES. . co LABEL ACCORDING TO LOCATION._ 4 ASSEMBLY:, SECOND FLOOR ATTACHING STRUCTURAL PANEL, FASTEN TO BUILDING w/#8x3 (w/WASHERS)GALVINIZED OR t 16"O.C. OR BETTER STAINLESS STEEL WOOD SCREW@ ' EX,KITCHEN EXIS G-BAT _ NEW BAT BUILDING. - _` IN — H ALTERNATIVE FASTNER FOR SHUTTER TO U : _.. ,__ 3 F.A.1. #10 TEE NUTS ATTACHED TO BLDG.w/#1 Ox 1 Yz (W/WASHERS)MACHINE BOLT @ 12 O.C.' 1 1/4 1 1/2 1112 1 114 _. , ,,1/a : 1112 .1112 NR MASONRY STUCCO THEY SHALL BE ATTACHED WHERE SCREWS ATTACH TO MASONRY OR , SI K ° -- V�I LAV , D.w. UTILIZING VIBRATION RESISTANT ANCHORS RAINING A MINIMUM WITHDRAWL CAPACITY OF 490 Ibs. : � _T_ B W. SHOWER 'I p 1 _ I � SHUTTER ASSEMBLYL v./ N.T.S. .: .... -: ,.. .�11n - 1n '1112 J2 : '� : W FOR PANEL SPANS.4-0 OR WIDER SPAN F- _ Z b- - +----- , I t W _-.._�. TO SUFFOLK COUNTY DEPT. SPECIFICATIONS AND ASSEMBLY IDENTICAL TO 0<4'-0"SPAN. � -} , '4"Cl -OF-HEALTH SERVICES _ V NOTE ADDITIONS: . HOUSE TRAP APPROVED SEWER LINE. —j (D Z 2x4 STRONG-BACKS @ 2 OC ASSEMBLY: O O 1). PREASSEMBLE PLYWOOD TO 2x4 S,# 10x3 ( )w/WASHERS GALVINIZED OR STAINLESS STEEL --� BASEMENT LL WOOD SCREW @ 12„O.C. (i ALTERNATIVE FOR OPENING PROTECTION SLOPE°1/4" 'ERFOOTPITCHTODRAIN Q _ —----- ---- .. _ - —-- -- ----- W----- -- IN THICKNESS OF 7/16"AND MAXIMUM PANEL SPAN OF 8'-0" WOOD STRUCTURAL PANELS WITH A MINIMUM T C SS 0 SHALL BE PERMITTED FOR OPENING PROTECTION IN ON AND TWO STORY BUILDINGS. PANELS -r, ti _ SHALL BE PRECUT TO COVER GLAZED OPENINGS WITH ATTACHMENT HARDWARE PROVIDED: �o � .: , (REFER TO SECTION 1609.1.4 AND 1609.6.5 AND TABLE 1609.1.4) / dr - F > ',• ;. -'- - .- f -,. � ��c"°':ram. i _ TABLE 1609.1.4 u WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS FASTENER SPACING INCHES F 0322.54-1 PANEL SPAN <2' 2'-0"< PANEL 4.-0"< PANEL 6'-0"< PANEL k FASTENER TYPE 0. SPAN <4-0 SPAN <6-0 SPAN < 8•0 OfE$$0 ; 2 1/2" .#6 WO PLUMBING DIAGRAM � D SCREWS : 16 16 12 9 0 -{� V l l NTS 2 1/2" #8 WOOD SCREWS 16 16 16 12 O v A. THIS TABLE IS BASED ON A MAXIMUM WIND SPEED (3 SECOND GUST)OF 130 MPH AND MEAN ROOF N : . HEIGHT OF 33'-0"OR LESS �. B. FASTENERS SHALL BE INSTALLED AT OPPOSING ENDS OF THE WOOD STRUCTURAL PANEL. C. WHERE SCREWS ARE ATTACHED TO MASONRY OR MASONRY/STUCCO,THEY SHALL BE I ATTACHED UTILIZING VIBRATION RESISTANT ANCHORS HAVING A MINIMUM WITHDRAWL >' CAPACITY OF 490 LBS. 4 i RIDGE- l RAFTER M 04 Z Q1 USP RS250 AT 21 — l t iQ 110 ! ;w r U I t ,— I ,W �m u I- , , (Z O , � : • II w , , E z w ! k a �cn !O , � . - I ! I .., � Q , Iz , ,w ; I —A - _ RAFTER/RIDGE/RAFTER wITH CT r _ •;;` . ;, ,, ` _ - KING STUDS RAFTER —0 •• - - lwl , RIDGE -- RAFTER STUD ---- - - ;Z) ! I ( 1 , 01 USP RT16 OR(2)RT7. RAFTER ! Y • - _ _- . • !W p l F TOP PLATE TOP PLATE ---Q HEADER � • . : ;I-I ,- J ; i I USP RT3 '� Q USP RT20— USP RS250 AT 18" - - O F- USP LS OR TMU IE 1-, USP RS250 AT 12" WALL STUD fl WALL STUD rJ Ip Q " CONNEC TION USP PRODUCT NUMBER p' U 'w! JACK STUDS A RAFTER/RIDGE/RAFTER WITH CT" RS250 21" ?Q! ' RAFTER/RIDGE/RAFTER : WITHOUT CT RS250 21„ I + LSSH179 cl, B RAFTER/PLATE/STUD RT20 I II } RAFTER/PLATE RT16 or(2)RT7 . PLATE/STUD RS250 18 Al ,RAFTER/RIDGE/RAFTER W/o cr B RAFTER/PLATE/ST D r _ _ ..-_ _.._:_ _1 _ - _ _ _ _ � _. _ _:_B RAFTER/PLATE PILATE/STUD I j � HEADER/STUD RT3 _ C_ .�HEADER/STUD HEADER/JACK HEADER/JACK STUD RS250 12 D FLOOR TO FLOOR 0 KLFTA or RS250 36" - E STUD/PLATE/SILL RS250 36 O IL 0 STUD/PLATE RS250 16 h I : Z � Y• PLATE/SILL f MP6F W � � F ANCHOR BOLTS - r. STB16 � S° PAU SERIES G POSTANCHOR FOR DECK U' co POSTANCHOR FOR COVERED PORCHES CBE SERIES 1X6 OR 2X4-16"O/C COLLAR TIES MIN.. __• __ O o Z ti k , „r POST tLu USP CBE P.C.FOOTING 0FEeSs 1®� . a 2ND. FLOOR WALL STUD � 2ND.FLOOR WALL STUD fl - - 1 ST.FLOOR WALL STUD 1 ST.FLOOR WALL STUD- 1 0 o I cn 2ND.FLOOR PLATE ;- 2ND. FLOOR PLATE F- SUBFLOOR _ �_ SUBFL "��_ 1 G `POST ANCH Z OOR . • � _.__ -----,---___..�_.___. __- __..OR FOR COVERED PORCHES _ 1ST.FLOOR _ - -, ..__. - - W , PLATE U 1ST.FLOOR PLATE v _ _ . _ _.-- ----- __ _. RIM BOARD �: RIM BOARD ' SUBFLOOR SUBF �\ U USP K -- LOOR LFTA USP RS250 AT 36 _ USP RS250 AT 36" - " Z USP RS250 AT 16 - 1ST.FLOOR TOP PLATES-- . -- `_ __ RIM BOARD RIM BOARD =1ST.FLOOR TOP PLATES O DOUBLE SILL PLATE DOUBLE SILL PLATE — --=- POST fl ILL USP MP6F - 1 ST FLOOR p WALL STUD fl 1 ST FLOOR WALL STUD Z FOUNDATION WALL Q FOUNDATION WALL --- USP PAU C P.C. F - D FLOOR TO FLOOR D - FLOOR TO FLOOR E}_ - r _ - STUD/PLATE/SILL -L-- ! E STUD P/ LATE P _ ._ _ _ LATE/ SILL_:__ �� _. -y_� .�_-:-- - :___:_ _ _._�___ __ _:-�. .__-: _- -___ __� _ _____ _. . _ - G POST AN 1. . __.. CHORS FOR DECKS N { i _ I GENERAL CONSTRUCTION NOTES . • i GENERAL FRAMING NOTES i I n 2 t grade or better 16"o/c. All other framing material NAILING SCHEDULE ' 1. The Information on this set of construction documents is to relate basic design 1.All walls, 2x4 and x6,to be stud d g I to be#2 dou las fir or better. intent and framing details. They are intended as a construction aid, not a substitute 9 TABLE 3.1 INCLUDING 3.3 AND 3.9 ! j I for generally accepted good building practice and Compliance With current New YO 1995 SBC HIGH WIND EDITION WOOD FRAME CONSTRUCTION MANUAL I I r providing standard 2.All wood framing in contact with concrete or masonry to be pressure treated. Y state building codes. The general contractor is responsible for p g 9 JOINT DESCRIPTION NAIL QUALITY NAIL SPACING i construction details and procedures to ensure a professionally finished, structurally ,. - 3. Provide double floor joists Under all walls parallel to floor joist span direction unless ROOF FRAMING sound,and weatherproof completed product. 1 P 1 P RAFTER TO TOP PLATE TOE NAILED - Otherwise specified. 8-0 WALL. 3-8d PER RAFTER I '� W P 10'-0"WALL:4-8d , PER RAFT In I '(� j ' ER (0 - : W . 2. General Contractor to coordinate all sub contractors,scheduling of work,and CEILING JOIST TO TOP PLATE TOE NAILED 8-0 WALL. 3-8d PER JOIST I Q . „ J T pii,.:il= ; ice , • 4. Provide x-bracing or solid blocking at a maximum of 8-0 o/c for all dimensional 10'-0"WALL:a-sd PER Interaction between trades. 9 9 JOIST ~ af I !z CEILING JOIST TO PARALLEL RAFTER FACE NAILED SEE TABLE 3.7 EACH LAP Q I , lumber floor Joists. o IW i- r CEILING JOIST LAPS OVER PARTITIONS ' FACE NAILED SEE TABLE 3.7 EACH LAP ' !LU ! 'm '� 3.The general Contractor IS reSPOrlSlble for ensuring that all Work and COr1StfUCtlOn COLLAR TIE TO RAFTER FACE NAILED SEE TABLE 3.4 PER TIE g , ! O w ';z tr ction tongue and groove plywood subfloor. Finished material to be : W : meets or exceeds current federal, state,and local codes,ordinances and regulations, 5. Floorcons u / g g p y BLOCKING To RAFTER TOE NAILED , 2-8d EACH END 'W iIZ : j> IW r be considered as art of the specifications for this buildingapplied over SUbfloor. Glue and screw plywood decking t0 floor joists. : RIM BOARD TO RAFTER END NAILED 2-16d EACH END ;Q Cn O ! ;J C etc. These codes are to c p p and should be adhered to even if the are in variance with the plan. IQzw Y WALL FRAMING i l I 6.All window and door headers t0 be minimum (2)2X10 Un12SS Otherwise Specified. TOP PLATE TO TOP PLATE FACE NAILED 2-16d PER FOOT 1 - I 1 `scale drawings do not scale drawings). All interior headers t0 be(2)2X10 UnI2SS Otherwise Specified.` TOP PLATES AT INTERSECTIONS FACE NAILED 4-16d JOINTS - EACH SIDE I 4. Dimensions shall take precedent overs ( � I -, STUD TO STUD ` FACE NAILED. 2-16d 24"O/C I 1 HEADER TO HEADER '. FACE NAILED :C ' 16d 16 O/C ALONG EDGES 7.Provide full solid blocking under all beano walls. - 5.The designer has not been engaged for COnStrUCtlOn Supervision and assumes n0 g g TOP OR BOTTOM PLATE TO STUD END NAILED 2-16d PER 2X4 STUD ! responsibility for construction coordinating with these plans, nor res onsibili for - 3-1sd PER 2xs sruD G P Y 9 P p tY - 8.All beams to have adequate beano at each end or as specified. 4-16d PER 2x8 STUD I construction means, methods,techniques, sequences,or procedures,or for safety q 9 p ' BOTTOM PLATE TO FLOOR JOIST. ,. precautions and programs in connection with the work. There are no warranties fora BANDJOIST END JOIST OR BLOCKING FACE NAILED - P P g E 2-16d PER FOOT.. i in the use of these plans. 9.All flush beam and Joist intersections to have galvanized hangers: W specific use expressed or implied p � r FLOOR FRAMING UX; ! JOIST SILL TOP PLATE OR GIRDER A ., . ' � 70E NAILED 4-8d PER JOIST � I schedule or es and sizes of 10.T ical exterior walls and roof to be sheathed with / exterior grade plywood or ! : 6. Refer to floor plans,exterior elevations, and windowf types YP BRIDGING TO JOIST TOE NAILED 2-8d EACH END •O! k 7/16 OSB plywood,group 1 APA rated. Plywood to span over plates and windows. All windows to be Andersen high performance quality or approved equal. P Y 9 P Y P p BLOCKING TO JOIST TOE NAILED 2-8d EACH END ` headers. BLOCKING TO SILL OR TOP PLATE TOE NAILED 3-16d EACH BLOCK I LEDGER STRIP TO BEAM FACE NAILED 3-16d EACH JOIST Imo; W otherwise no Io ' 7.Door and window headers to align unless othited. g JOIST ON LEDGER TO BEAM TOE NAILED 3-8d PER JOIST i I J' 11. Provide insulation baffles at eave vents between rafters. BAND JOIST TO JOIST END NAILED 3-16 Z, O d PER JOIST < { BAND JOIST TO SILL OR TOP PLATE TOE NAILED 2-16d PER FOOT 0 ! 8.General contractor is to ensure that masonry and prefabricated fireplace -: Z i construction meets or exceeds all manufacturer's specifications and applicable codes. 12. Exterior flashing to be correctly installed at all connections between roofs,walls, ROOF SHEATHING ; j< , chimneys, projections,and penetrations as required b approved construction U, O: _ y , P 1 P 4 Y PP ,U I , I practices. STRUCTURAL PANELS 4 PERIMETER EDGE ZONE- 16 O/C -6 AT PANEL EDGES � I t 9. General contractor to consult and coordinate with the owner and the plans for all p , , Q, � i , I 8d , AND AT INTERMEDIATE SUPPORTS IN THE PANEL FIELD ! !! built in items such as bookcases,shelving,pantry,closets,etc. 1 General contractor to provide adequate attic ventilation and roof vents. INTERIOR ZONE - 16"O/C -6"AT PANEL EDGES AND 12" 13. n p q 8d AT INTERMEDIATE SUPPORTS IN THE PANEL FIELD I Or n n each . FOR ROOF SHEATHING WITHIN 4-0 OF THE PERIMETER EDGE OF THE ROOF INCLUDING 4-0 I I-- • I . !10. Provide hardwired smoke detectors,with battery backup,on all floors and I e C ON EACH SIDE OF THE ROOF PEAK,THE 4-0 t bedroom,verifywith local code requirements as per Section R317, New York State 14.Provide appropriate soffit ventilation at overhangs. PERIMETER EDGE ZONE ATTACHMENT REQUIREMENTS SHALL BE USED. q Residential Construction Code. Install carbon monoxide detectors as per code. CEILING SHEATHING - C GENERAL PLUMBING NOTES i GYPSUM WALLBOARD 5d COOLERS 7"EDGE/10" FIELD I GENERAL FOUNDATION NOTES 1. Plumbing subcontractor to be responsible for adhering to all applicable code and------------ WALL SHEATHING - - safety requirements. STRUCTURAL PANELS 4 EDGE ZONE 16 O/C 6 AT PANEL EDGES AND 12 AT co f contractor n details determine Intended 8d INTERMEDIATE SUPPORTS IN THE PANEL FIELD - (` 1. General co t actor to review a d d to < � INTERI R ZONE -16"O/C -6"AT PANEL EDGES AND 12 O heights of finished floors above typical grade. 2. If wall plates or joists are cut during the installation of plumbing fixtures or -� o g O tYP g P 1 g Sd AT INTERMEDIATE SUPPORTS IN THE PANEL FIELD d equipment rovide bracing to tie framing back together. _ " P g g g FIBERBOARD PANELS 7/16 6d 3 EDGE/6 FIELD Z 2.All footings t0 rest On Undisturbed Soil. I - 25132 Sd 3 EDGE/6 FIELD U-1 Nt l GYPSUM WALLBOARD 5d COOLERS 7 EDGE/10 FIELD W Ni GENERAL HVAC SYSTEM NOTES _ : --- --- - - ----- --- --- o r_ • .:.' I 4'EDGE ZONE -16"0/C -6"AT PANEL EDGES AND 12 AT � c- M 3. Provide h expansion joint material between all Concrete slabs and abutting HARDBOARD 8d INTERMEDIATE SUPPORTS IN THE PANEL FIELD (� �- (0 i responsible for adhering to all applicable codes and I INTERIOR 6" 6„ concrete or masonry walls occurring in exterior or unheated interior areas. . . 1. Mechanical subcontractors respons o g pp � NTER oR ZONE 1 o/c AT PANELEDGES AND 12 - safety requirements. - 8d AT INTERMEDIATE SUPPORTS IN THE PANEL FIELD 4.Concrete on 4 sand or gravel fill minimum,with 6x6-101 10 wire mesh reinforcing. FLooR sHEATHiivG > o Q I ` Interior slabs to be laced on 6 mil. stabilizedpolyethylene va or barrier. 2. HVAC subcontractor to fully coordinate all system data and requirements with the STRUCTURAL PANELS - 1"OR LESS 8d 6"EDGE/12"FIELD P P O o equipment supplier. : NAILINGREQUIREMENTS R IN " 1 E PANEL ED ,IF WALL " r ARE BASED ON WALL SHEATHING NAILED 6 O C AT THE GE.; A L SHEATHING IS NAILED 3 O/C AT THE 5;Provide Crawl Space ventilation per IOCaI Code requirements. PANEL EDGE TO OBTAIN HIGHER SHEAR CAPACITIES,NAILING REQUIREMENTS FOR STRUCTURALMEMBERS SHALL BE DOUBLED OR ALTERNATE Z 3. HVAC subcontractor to provide finals stem layout drawin and submit it to eneral CONNECTORS, P Y Y 9 g SUCH AS SHEAR PLATES, SHALL BE USEDTO MAINTAIN THE LOAD PATH Q � 6. General contractor to install co -r-tex or copper)sheet metal termite shields contractor,owner, and equipment su supplier review and approval. - WHEN WALL SHEATHING IS CONTINUOUS OVER CONNECTED MEMBERS,THE TABULATED NUMBER OF NAILS SHALL BE PERMITTED TO BE P ( PP ) PP PP REDUCED TO 1016d NAIL PER FOOT. (O between all wood surfaces that are exposed to concrete or masonry surfaces. - ; NEW CODE 1 7. Dam roof exterior of foundation with a bituminous coating as per code and soil f PP 9 I_ - GENERAL WIND PROTECTION CONNECTION NOTES TABLE 3.4 conditions. _ ..-_----_---------__-___.__--__.-__ TABLE3.7 Adapted from Standard for Hurricane Resistant Residential Construction; SSTD 10-99 1995 SBC HIGH WIND EDITION WOOD 1995 SBC HIGH WIND EDITION WOOD FRAME CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA and 1995 SBC High Wind Edition Wood Frame Construction FRAME CONSTRUCTION MANUAL CONSTRUCTION MANUAL WEATHERING SEVERE Fasteners and Connectors for Wood Frame Construction RAFTER SPACING 16"O/C RAFTER SPACING W O/C GENERAL FLOOR PLAN NOTES 120 mph FASTEST WINDSPEED FROST LINE DEPTH 3'-0" P ROOF PITCH ROOF SPAN TERMITE MODERATE TO HEAVY ' ' 1.A continuous load path betweenfootin s foundations walls floors studs and roof 12 2 i 1. Dimensions shall take precedent over scale drawings(do not scale drawings). p footings, 20 8 36 framingshall be provided. R F t�I�'IBER DECAY SLIGHT TO MODERATE P C N A 3:12 5 8 11 14 , PITH SPA (ft) - NAILS WINTER DESIGN TEMP. 11 2:All interior walls to be covered with / gypsum board With metal corner reinforcing. `. 4:12 4 6 8 11 - 4:12 12 3 ICE SHIELD UNDER- AS PER MANUFACTURER'S float, an sand 3 coats). 2.A roved connectors,anchors and other fastening devices not included in the 5.12 3 5 7 9 _, - _ PP g 16 4 5 6 LAYMENT REQUIRED SPECIFICATIONS/STATE CODE Tape, t� d ( (n Standard Building Code,Table 2306.1 shall be installed in accordance with 7:12 3 . 4 � 3.Walls common to garage and house to have ala layer of 5/8" fire rated sum board manufacturer's recommendations. 20 5 9:12 3 3 4 5 FLOOD HAZARDS W i 9 9 Y 9YP 24 6 12:12 31 31 3 4 at garage side with 5-0"return on adjacent walls and ceiling. Manufactured lumber 28 7 Z I „ requires 2 layers of 5/8 ,fire rated sum board. 3. Metal plates,connectors,screws, bolts,and nails exposed directly to the weather or 32 g W q Y 9YP subject to salt corrosion in costal areas, shall be stainless steel or hot dipped 36 _ U 1 ' 4.All bath and toilet area walls and ceilings adjacent to wet areas to have water galvanized. 5:12 12 3 C� 9 1 resistant gypsum board,or wall the set on wonderboard or equal. 16 4 Z 2 4 4.Where windows and doors interrupt wood structural panel sheathing and siding, 0 24 DESIGN LOAD CALCULATIONS framing anchors or connectors shall be provided at the top and bottom of cripple 5 O studs header studs and at least one stud at each side of opening. 28 6 O _ , 32 7 t J MINIMUM UNIFORMLY DISTRIBUTED .LIVE LOADS Ibsf UL EXTERIOR BALCONIES - 6 0 5. Ridge straps shall be attached to each pair of opposing rafters except where collar 6:12 12 3 r ties of 1 x6 or 2x4 lumber is located in upper third of attic space and attach to each air - Z F DECKS - 4 0 PP P P 16 3 'i-�9 ,Q I ATTICS WITHOUT STORAGE 30 of rafters. 20 4 1 W ATTICS WITH STORAGE 4 0 6. Uplift connectors shall be provided at each rafter bearing. ` 24 5 P P 9 ROOMS (OTHER THAN SLEEPING ROOMS 40 28 5 p I SLEEPING ROOMS 30 7. Floor to floor hold-downs to be provided eve 48,and eve 16 within 4 of exterior 32 6 -- corners. % e &1 1, 7:12-12:12 12 2 ,� O CRITERIA FOR CALCULATION OF DEAD LOAD - E 16 34- ACTUAL WEIGHTS OF. MATERIALS REFERENCED TO A.I.A. 8. SIII Plate to Foundation Anchorage. SIII plate shall be anchored to the foundation ARCHITECTURAL GRAPHIC STANDARDS with anchor bolts having a min. bolt diameter of 5/8 and 3 x 3 x 1/8 washers. A 24 a ti4 minimum of one anchor bolt shall be provided within 6 to 12 inches of each end of - 'P8 5 L, SNOW each plate. Anchor bolts shall have a minimum embedment of 7 inches in concrete/ 32 6 GROUND SNOW LOAD 145 I b s. masonry foundations. Anchor bolts shall be located within 12 inches of comers and at 36 6 C` ' FD 032254-1 SEISMIC spacing not exceeding 4 feet on center. 9Qt; iJNR�,f DESIGN CATEGORY IB THESE NOTES ARE GENERAL CONSTRUCTTON NOTES.'THEY ARE NOT WIND i WIND SPEED 120 mph SPECIFICALLY WRITTEN FOR THIS PLAN. THEY ARE TO BE CONSIDERED AS 0 EXPOSURE CATEGORY 8 GENERAL GUIDELINES ONLY AND SHOULD BE DISCUSSED WITH YOUR p GENERAL CONTRACTOR BEFORE CONSTRUCTION BEGINS: - h' _ I, : 1