HomeMy WebLinkAbout32550-Z FORM NO. 4
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Office of the Building Inspector
Town Hall
Southold, N.Y.
CERTIFICATE OF OCCUPANCY
No: Z-32132 Date: 01/10/07
THIS CERTIFIES that the building WOOD STOVE
Location of Property: 7980 NORTH BAYVIEW RD SOUTHOLD
(HOUSE NO.) (STREET) (HAMLET)
County Tax Map No. 473889 Section 79 Block 7 Lot 52
Subdivision Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore
filed in this office dated DECEMBER 5, 2006 pursuant to which
Building Permit No. 32550-Z dated DECEMBER 5, 2006
was issued, and conforms to all of the requirements of the applicable
provisions of the law. The occupancy for which this certificate is issued
is INSTALLATION OF A WOOD STOVE IN AN EXISTING SINGLE FAMILY DWELLING AS
APPLIED FOR.
The certificate is issued to KIM W & HEATHER TETRAULT
(OWNER)
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A
ELECTRICAL CERTIFICATE NO. N/A
PLUMBERS CERTIFICATION DATED N/A
uth'F(rized Signature
Rev. 1/81
Form No.6
- TOWN OF SOUTHOLD ..._ . _ .
BUILDING DEPARTMENT 1
TOWN HALL f DEC 8 2006
765-1802
s
APPLICATION FOR CERTIFICATE OF OCCUPANCY P t;
This application must be filled in by typewriter or ink and submitted to the Building Department with the following:
A. For new building or new use:
1. Final survey of property with accurate location of all buildings,property lines, streets, and unusual natural or
topographic features.
2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form).
3. Approval of electrical installation from Board of Fire Underwriters.
4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead.
5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate
of Code Compliance from architect or engineer responsible for the building.
6. Submit Planning Board Approval of completed site plan requirements.
t
B. For existing buildings (prior to April 9, 1957)non-conforming uses, or buildings and "pre-existing" land uses:
1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic
features.
2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is
denied, the Building Inspector shall state the reasons therefor in writing to the applicant.
C. Fees
1. Certificate of Occupancy-New dwelling$25.00, Additions to dwelling$25,.00,Alterations to dwelling$25.00,
Swimming pool$25.00, Accessory.building$25.00,-Additions-to accessory,building$25.00, Businesses $50.00.
2. Certificate of Occupancy on Pre-existing Building- $100.00
3. Copy of Certificate of Occupancy-$.25
4. Updated Certificate of Occupancy- $50.00
5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00
Date. p
New Construction: Old or Pre-existing Building: (check one)
Location of Property: q� D lvU� `h &,!J V�{,�
House No. Street Hamlet
Owner or Owners of Property: P,,A k,
Suffolk County Tax Map No 1000, Section Block Lot sa
Subdivision Filed Map. Lot:
3z55o Ia - . II
Permit No. Date of Permit. Applicant:
Health Dept.Approval: Underwriters Approval:
Planning Board Approval: tJ
Request for: Temporary Certificate Final Certificate: (check one)
Fee Submitted: $
Applicant Signature
C, 3.21 1 3
� 0
FORM NO. 3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Town Hall
Southold, N.Y.
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL
COMPLETION OF THE WORK AUTHORIZED)
PERMIT NO. 32550 Z Date DECEMBER 5, 2006
Permission is hereby granted to:
KIM W TETRAULT
7980 NORTH BAYVIEW RD
SOUTHOLD,NY 11971
for
INSTALLATION OF A WOOD STOVE AS APPLIED FOR.
at premises located at 7980 NORTH BAYVIEW RD SOUTHOLD
County Tax Map No. 473889 Section 079 Block 0007 Lot No. 052
pursuant to application dated DECEMBER 5, 2006 and approved by the
Building Inspector to expire on JUNE 5, 2008 .
Fee $ 150 . 00
_ AU horized Sign
ORIGINAL
Rev. 5/8/02
Of so
o�y00UMY,�
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLOG.
[ ] FOUNDATION 2ND [ ] INS ATION
[ ] FRAMING / STRAPPING [ INAL
[ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
REMARKS: T .a Hi,9477-f TLD
DATE �Z- ® INSPECTOR
4
LI
FIELD INSPECTION REPORT DATE I COMMENTS
ro
�I
.FOUNDATION(1ST)
c
-------------------------------------
FOUNDATION (2ND) �
ROUGH FRAMING& -
PLUMBING --
C
INSULATION PER N.Y.
H
STATE ENERGY CODE
V`
v
d
FINAL
ADDITIONAL COMMENTS
O
Z
m
P
l �C
d
z
y
C
trJ
ro
H
TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST
BUILDING DEPARTMENT Do you have or need the following,before applying?
TOWN HALL Board of Health
SOUTHOLD,NY 11971 4 sets of Building Plans
TEL: (631) 765-1802 Planning Board approval
FAX: (631) 765-9502 Survey
www. northfork.net/Southold/ PERMIT NO. ��S��C�� Check
Septic Form
N.Y.S.D.E.C.
Trustees
Examined �fi' ,20 Contact:
Approved ,20_/ Mail to:
Disapproved a/c
Phone:
Expiration ,20
ing In ector
APPLICATION FOR BUILDING PERMIT
20
Q�Q Date Dec � , 20 O
�L •'�`. INSTRUCTIONS
a. This app�l�,icatiorrl`VST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4
sets of plans,kaaoeurt e plot plan to scale. Fee according to schedule.
b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or
areas, and waterways.
c. The work covered by this application may not be commenced before issuance of Building Permit.
d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit
shall be kept on the premises available for inspection throughout the work.
e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector
issues a Certificate of Occupancy.
f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the
property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an
addition six months. Thereafter, a new permit shall be required.
APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or
Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described.The
applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations, and to admit
authorized inspectors on premises and in building for necessary inspections. �.
APPRO D AS NOTED (Signature of applicant or name,if a corporation)
DATE: �� B.P. q oh
FEE: R`!: / �— (Mailing address of applicant)
OT .Y BUILDING :�—ARTNIENT AT so„i-t�J
State whether 8pn iA c vfr47 s%gg , architect, engineer, general contractor, electrician, plumber or builder
ECT
WTI' (- TWO REQUIRED
FOR POURED CON . E
�l
Name of owner isE$AMIN �Q4B
3. INSULATION (As on the tax roll or latest deed)
If applicant is 4a tftfa0n S � �W.Rh��ly authorized officer
BE COMPLETER'
(Nam 2 repr��@ ig&NEW
YORK STATE. NOT RESPONSIBLE FOR
Builders LiceiDgSt�g OR CONSTRUCTION ERRORS.
Plumbers License No.
Electricians License No.
Other Trade's License No.
1. Location f land on which proposed work will be done: 4 � Q
8 N=N
House umber Street Hamlet
County Tax Map No. 1000 Section Block Lot
Subdivision Filed Map No. Lot
(Name) l
2. State existing use and occupancy of pre�,ses and intended use and occupancy of proposed construction:"
a. Existing use and occupancy J ;-s
b. Intended use and occupancy SGi .rtiSZ
3. Nature of work (check which applicable): New Building Addition Alteration
Repair Removal Demolition Other Work wtoa,s-h-VC Ch i+c. bl- cpq
(Description)
4. Estimated Cost Fee
(To be paid on filing this application)
5. If dwelling, number of dwelling units Number of dwelling units on each floor
If garage, number of cars 9
6. If business, commercial or mixed occupancy, specify nature and extent of each type of use.
7. Dimensions of existing structures, if any: Front Rear Depth
Height Number of Stories
Dimensions of same structure with alterations or additions: Front Rear
Depth Height Number of Stories
8. Dimensions of entire new construction: Front Rear Depth
Height Number of Stories
9. Size of lot: Front Rear Depth A
10. Date of Purchase Z Name of Former Owner -Sk lfe Pa A'L �-�-
11. Zone or use district in which premises are situated
12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO
13. Will lot be re-graded? YES NO-1-1-1 excess fill be removed from premises? YES NO
14. Names of Owner of premises_ Address Phone No., ,.
Name of Architect Address Phone No
Name of Contractor Address Phone No.
15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO
* IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED.
b. Is this property within 300 feet of a tidal wetland? *YES NO O`
* IF YES, D.E.C. PERMITS MAY BE REQUIRED.
16. Provide survey, to scale, with accurate foundation plan and distances to property lines.
17. If elevation at any point on property is at 10 feet or below, must provide topographical data"on survey.
STATE OF NEW YORK)
SS:
COUNTY OF '��t
ect-V�er l ;i being duly sworn, deposes and says that(s)he is the applicant
(Name of individual signing contract) above named,
(S)He is the
(Contractor, Agent, Corporate Officer, etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;
that all statements contained in this application are true to the best of his knowledge and belief, and that the work will be
performed in the manner set forth in the application filed therewith.
Svc before me t
C day of ( 20010 C
Nk 1� h
NotarktuAic Signature of Applicant
MELANIE
State New YorkNo, 01D0,4634870
Qualified in Suffolk County
Commission Expires September 30,2LQ1 0
i
\a
SAFETY NOTICE:
IF YOUR DEFIANT,VIGILANT,RESOLUTE OR IN.
IS NOT PROPERLY INSTALLED, A HOUSE 1
FIRE MAY RESULT. FOR YOUR SAFETY, FOLLOW
THE INSTALLATION DIRECTIONS. CONTACT LO• `
CAL BUILDING OR FIRE OFFICIALS ABOUT RE, I b—�
STRICTIONS AND INSTALLATION INSPECTION
REQUIREMENTS IN YOUR AREA.
I
A separate bulletin, "The Vermont Castings Installation
Planning Guide" also entitled the "Tech Book", contains
detailed information to help you plan ypur installation. Read
this manual and the Guide before installing your stove. CORNER INSTALLATION
Building and safety codes vary in different localities. Check NO SHIELDING
COMBUSTIBLE WALL
your installation plans with local officials before you install a) load door end requires min.36"to wall
your stove. b) Min.36"clearance to wall from rear and side
The Resolute and Intrepid have been tested for use in
mobile homes. Special mobile home chimney, clearance, and So that you can easily secure the first section of stove pipe to
installation requirements are detailed in the Mobile Home the stove, three holes have been drilled in the flue collar and
Components Installation Instructions. three sheet metal screws are included in the leg bolt package.
When either the Vigilant or Resolute is equipped with a If you have ordered any accessories such as andirons or heat
Vermont Castings Energy Extender, clearance requirements shields, they will come with their own installation instructions.
may change. The Energy Extender Installation Instructions Generally speaking, nothing more complicated than a screwdriver
give spepial clearance information. is involved in the installation of accessories.
The set screw in the lower left front of the Vigilant and
Resolute will be removed if the stove is converted to coal burn- Clearances
ing. The hole should be plugged-when burning wood. It is important for proper installation that the stove is
Packed inside your stove is a "Fall-Away Insert Handle" to located with adequate clearance (empty space) to combustible
operate the doors and damper. So that it will stay cool, store walls and room furnishings. The recommended minimum
the handle in the hole drilled in clearance for stoves is usually 36".
one of the stove legs. FIRE BACK Vermont Castings stoves have been tested by independent
Defiant owners: Install the BACK S F E laboratories for installation with reduced clearances when
smoke shelf by closing the damper <: specific clearance reduction systems are used. Clearance reduc-
and angling the shelf through the tions may vary depending on the stove and type of
flue collar opening. Position the installation.
shelf as shown. Consult the Vermont Castings Installation Planning Guide or
Tech Book for specific clearance reductions for Vermont
Set Up Castings stoves.
Our stoves are heavy and require at least two people to move Chimneys
and set them up. To make the job a bit easier, you may lift off
the loading doors and remove the griddle. Many homes are already equipped with a sound freestanding
DO NOT TRY TO MOVE THE STOVE masonry chimney or a fireplace chimney. Either of these can pro-
ALONE AS THE STOVE CAN BE vide an excellent flue through which to,vent a wood or coal stove,
DAMAGED BY MISHANDLING. provided they are built according to local building codes. We
Place the stove close to its final position before installing the recommend that prior to installing a stove into an existing flue,
stove legs. You will find stove leg assembly instructions in the leg you have the chimney inspected by a qualified professional. Your
bolt package. local building inspector will know who is qualified to assess the
The griddle has not been painted in order to allow cooking condition of your chimney. If your masonry chimney is not con-
directly on its surface. In order to protect the surface from rust strutted with a clay tile liner, we cannot recommend that you use
during shipping, a coating of grease has been applied. Be sure to it in its existing state with any wood or coal burning device. An
wash the griddle thoroughly with soap and water. As the stove is unlined chimney may have unseen loose mortar which could allow
used,the griddle will gradually darken to match the color of the stove. chimney gases to escape into the house, or, a chimney fire could
ignite nearby wooden members.
6
r
b t
� ® a
JIM
o Iy
c It-ate►
b
FIG.2 FIG.3
SIDE INSTALLATION TOP EXIT DEFIANT
REAR PIPE AND STOVE SHIELDS SIDE INSTALLATION
COMBUSTIBLE WALL NO PROTECTION
a)Min.36"clearance to wall from side COMBUSTIBLE WALL
b)Min.10"clearance to wall with use of stove and pipe heat shields a)Min.36"clearance to wall from side and rear
c)Min.36"clearance from loading door to any combustible room furnishings b)Min,36"clearance from load or front doors to any combustible materials,
i.e.,furniture
If you are building a chimney from scratch,we cannot stress expensive than their masonry counterpart. Make sure that such a
strongly enough the importance of an interior chimney. When chimney is approved for solid fuel and is listed by a nationally
properly built,it is the best chimney of all, and will more than recognized testing laboratory such as the Underwriters Laboratory
repay you for the space that it requires. Besides minimizing conden- (UL). It must be installed in accordance with the manufacturer's
sation of creosote,the draft produced in an interior masonry chim- instructions. CLASS B type chimneys may not be used with
ney will be stronger, helping the stove bum more efficiently. In wood or coal stoves. These flues are designed to vent gas appli-
new masonry construction,allow for the use of a minimum of ances only. There are several prefabricated chimney designs
eight by eight inch clay flue tile.The chimney must be constructed available; we recommend those which will help maintain high flue
in accordance with your local building code. gas temperatures, such as the double wall or static air insulated
You may prefer to install a factory built metal chimney. Pre- type. Ask your local dealer about specific manufacturers.
fabricated chimney systems require no foundation and are rela- Do not connect the stove to a chimney flue serving another
tively quick and easy to install. Other advantages of prefabricated appliance.
chimneys are that they generally require less space and are less
"t.. T
T
3' IDEAL FLUE SIZES
a 2' Vermont Castings stoves are designed to perform most efficiently when
IQ+ - vented through flues having the following dimensions:
Liner Size Round
' (nominal) Liner Diameter
Defiant/Vigilant 8"x8" or 8"xl2" 8" interior diameter
Resolute/Intrepid 8"x8" or 8"xl2" 6" interior dia.
Larger flues(12"xl2",12"xY'),although generally effective,can lessen
- chimney draft and promote cool flue gas temperatures.Vermont Castings
stoves are not listed for installation into flues smaller than the sizes recom-
FLUE HEIGHT REQUIREMENTS mended above.
The chimney must extend 3 feet above the level of roof penetration and If you are planning to vent a small stove into a large flue,particularly
a minimum of 2 feet higher than any roof surface within 10 feet.Check an exterior masonry one,you may find it necessary to insulate the chimney,
your local codes for additional regional guidelines. While a minimum reline the chimney,or operate the stove to maintain high flue temperatures.
chimney height of 16 feet is generally recommended, factors affecting
stove performance such as local terrain,prevailing winds,and adjacent
structures may necessitate use of a taller flue.
7
Stovepipe/Chimney Connector
We recommend that stoves be placed close to their chimneys
s0 that the stovepipe can be as direct and short as possible, with
a minimum of elbows and angles. Exhaust gases from the stove '
will flow unrestricted into the chimney flue. Long horizontal runs
g
of stovepipe should be avoided since they tend to build up ash
and soot more quickly and, therefore, require more frequent f e
cleaning. g
The size of a stovepipe and chimney thimble should never be h o ., ® b
smaller than the flue collar area of the stove. A minimum 8 inch d
diameter stovepipe and chimney thimble are required for the
Defiant and Vigilant, and 6 inch minimum diameter for the
Resolute. o
The stovepipe must be constructed of 24 gauge or thicker
sheetmetal. All stovepipe sections should be fastened together with
three sheetmetal screws, spaced equidistant around the perimeter
of the pipe to prevent separation during use. In addition, the
stovepipe should be fastened to the thimble and to the flue collar e®
of the stove.
Stovepipe systems should be designed if possible with the t
crimped end of the stovepipes pointing downward so that any
soot or creosote which is formed will run down back into the
SfOVe and be consumed. TOP•EX1T STOVE INSTALLED IN THIMBLE THROUGH COMBUSTIBLE WALL
a) Tile liner
b) Thimble
c) Stovepipe extends until flush with chimney liner.
d) Proper clearance between pipe and unprotected combustible materials.
e) 2"min.between chimney and combustible materials
f) V rise per foor of horizontal run
g) Clean-out tee
Horizontal or vertical runs of stovepipe h) All pipe joints secured with 3 sheet metal screws
i) Stovepipe heat shield allows 10"clearance to combustible materials
must be installed to maintain the j) Stove heat shield allows 10"clearance to combustible materials
Bottom heat shield
1)
following clearances to unprotected p Clean-out access with tight door
combustible materials.
9
° Defiant Installation - 22" Stovepipe Dampers
° ° Vigilant Installation - 22" Because of the draft requirements of our stoves, we do not
o' b Resolute Installation - 23" recommend the use of an in-flue damper. Not only is this an un-
Intrepid Installation - 25" necessary restriction in the flue, but it is an additional surface
directly in the path of flue gases upon which deposits can form,
Stovepipe heat shields and/or wall pro- creating a potential hazard. Combustion air entering Vermont
tection can be used to reduce these Castings stoves is controlled effectively by the thermostat, so no
clearances. See the Vermont Castings flue damper is required.
° Installation Planning Guide or Tech
° ° Book for detailed information concern- Floor Protection
ing your specific installation requirements.
Even though temperatures under our stoves are significantly
All chimney connections should be lower t}an those to the sides of the stoves, no stove should ever
carefully made in accordance with all be installed on a combustible surface because of the possibility of
local building codes and manufacturers' falling embers. Our stoves have generous ashlips, but some coals
recommendations. may escape from time to time. For this reason, and to provide
0— heat protection to your floor, we recommend you install a hearth
0- a consisting of two sheets of 1/4-inch asbestos cementboard or equi-
valent),covered by one sheet of 24 gauge galvanized sheet metal.
If you prefer a more decorative hearth cover than the above
recommendations, the installation of an optional Vermont Cast-
ings' bottom heat shield will allow use of a variety of materials.
Details concerning those options are printed in Vermont Castings'
Installation Planning Guide or Tech Book.
We recommend that your hearth or stove pad extend a
minimum of twelve inches beyond the back and sides of the stove
8
a
d ®
Em
----- ��
_- •®c b c � -b-
Eon1
1 ®® f ,H
1 • I ,0 ' ,,� O��,u'�
I
.'�,. * ,!
h
®®•a• VERMONT CASTINGS STOVE•TO•FIREPLACE FLEX CONNECTOR SYSTEM
•'a.,:.•.. , _,
• ,.p;,;;c,.. �,.o a)Tile-lined masonry chimney built to or in compliance of National Building Code
standards
FIREPLACE INSTALLATION-ABOVE DAMPER b)Vermont Castings Stove•to•FirePlace Flex Connector System
a)Tile-lined masonry chimney c)Combustible mantle protected by custom fabricated heat shield-allows 18"
b)Thimble clearance to stove top
c)Stovepipe should not project into flue d)Bottom heat shield
d)Horizontal pipe heat shield allows min. 7" clearance to combustible ceiling e)Hearth extension to provide min. 18" floor protection from stove front load
e)Vertical pipe heat shield allows min. 7"clearance to combustible mantle door and 12"'from side of stove
i)Damper closed and sealed
g)Bottom heat shield protects combustibles beneath hearth
h)Hearth extension provides floor protection min. 18"from stove front,load door&
12"from stove sides
and eighteen inches beyond the front and loading door end, Wall Protection
This means that the minimum hearth pad dimensions for the
three stoves are as follows: Clearances to combustible walls can be further reduced with
Defiant: 64 inches wide x 48 inches deep the use of a. Vermont Castings stove and stovepipe heatshields
Vigilant: 53 inches wide x 48 inches deep and/or b. a properly sized and constructed wall shield. In our In-
Resolute: 52 inches wide x 46 inches deep stallation Planning Guide wall shields should be constructed of 1/4"
Intrepid: 46 inches wide x 46 inches deep non-combustible mineral board, and spaced at least 1" from the
The hearth pad must also cover the floor directly under the wall on non-combustible spacers. The ventilated shield should be
stovepipe and extend two inches on either side of the pipe, supported one inch off the floor and, if extended to the ceiling,
With the legs installed, the hearth in place, the flue connec- should stop one inch below the ceiling to allow for adequate air
tions made, and the stovepipe connections secured the only addi- circulation. Materials applied directly to a sheetrock and stud
tional preparation that needs to be done is the addition of about walls may not provide adequate protection because they will
llh inches of ashes or sand to the bottom of the Defiant, transfer heat to the combustible wall or framing members behind
Vigilant and Resolute as an insulating, protective layer. This them. For further information regarding wall shield sizing and
should be spread evenly across the bottom of the stove to pro- construction refer to the Veimont Castings Installation Planning
tect the bottom of the stove as well as the floor beneath from Guide or Tech Book.
excessive heat. Ashes taken from another stove or fireplace are
preferable, but sand may be used as well.
Resolute and Vigilant
b '� f Ash Fettles —
1 b The ash fettle serves as a log
and ash barrier at the base of
the front door.It can be removed t II
T by pulling one end up and out; _
a for the Vigilant pull upward on
1 the RIGHT end,for the Resolute
DEFIANT FLOOR PROTECTION pull upward on the LEFT end.
a= 18"
b=12"
9
OPERATION
Preheat the System
Kindle every fire in the same manner as you did during
the break-in period. When a moderately hot fire has been
established, (500 degree stovetop temperature), you may fully
Please read this section carefully.Improper load the firebox. Since a new charge of wood may slow the
stove operation can create hazardous condi• fire, leave the damper open until the fire has recovered suffi-
ciently to bring the surface temperature back to at least 500
tions and may result in damage to your stove. degrees. Do this each time you add wood. Preheating the stove
and flue system before adjusting your stove for a long burn
will promote efficient wood combustion and minimize creosote
Cast iron expands as it is heated and contracts as it is development.
cooled. Like an old Model A, your wood stove requires a Your stove is now ready to be set for a long burn in
break-in period to allow the cast iron plates to settle in. either the horizontal (damper closed) mode or the updraft
If allowed to gradually adjust to these changes, the metal will (damper open) mode.
withstand a great deal of thermal stress with no damage. Ex-
treme, rapid temperature changes, however, may cause the The Long Burn
castings to fracture or fatigue. For a long burn in the Horizontal Mode, close the damper
Before kindling your first fire, the bottom of the Defiant, and after 5 to 10 minutes adjust the thermostat lever to
Vigilant and Resolute must be insulated with 1112" of sand or maintain the desired burn rate and heat output during the
ashes. Never start a fire in the stove without this insulating burn period. Leave the secondary cover open.
layer. The Intrepid does not require an insulating layer on the For a long burn in the Updraft Mode, leave the damper
bottom. open and adjust the thermostat lever for the desired heat out-
Be sure to wash the oil coating off of the griddle with put. Close the secondary air cover so all incoming air will be
warm, soapy water and then towel it dry. The griddle will regulated by the automatic thermostat coil. Consumption of
gradually darken as it is heated. wood may be greater, and more frequent loadings may be re-
quired when burning updraft.
The First Fire Surface Temperatures
Monitor griddle temperatures with a surface thermometer.
The break-in procedure consists simply of a series of The usual operating range is 350-600 degrees, although slight-
eight to twelve small to moderate fires burned in the updraft ly higher temperatures are all right when extra heat is
mode. Set the damper in the open (updraft) position and needed.
move the thermostat lever to open the air intake shutter. Surface temperatures higher than 700 degrees are con-
The secondary air inlet, on the left side of the Defiant, sidered excessive. If any part of your stove or chimney con-
Vigilant, and Resolute, should also be left open. Build a vector glows you are overfiring. Should overfiring occur, close
small paper and kindling fire. After the kindling has caught the air inlet shutter enough to reduce the intensity of the
well and a good draft has been established, add two or three fire.
small diameter logs to the kindling charge. Let this fire burn Daily Maintenance
out and allow the stove to cool down before lighting the Good performance depends on air flow through the stove.
next fire. Every day, clear ash accumulations from the air ports in the
DO NOT USE CHARCOAL LIGHTER FLUID, fireback and at the left side of the stove.
GASOLINE, GASOLINE-TYPE LANTERN FUEL, Develop the habit of burning moderately hot fires twice
KEROSENE, OR OTHER FLAMMABLE LIQUID TO daily for 30 to 40 minutes in the updraft mode. This will
START OR 'FRESHEN' UP A FIRE IN YOUR STOVE. help prevent a build-up of creosote in the flue.
KEEP ALL FLAMMABLE LIQUIDS WELL AWAY Loading/Fireplace Use
FROM THE HEATER WHILE IT IS IN USE. ALSO, When the stove has been burning in the horizontal mode
NEVER USE SELF-STARTING CHARCOAL BRI- (damper closed), and you wish to open the doors for loading
QUETTES. or viewing, first open the damper and air inlet. This will re-
establish a fast, direct air flow through the stove into the flue
We suggest that the damper be left open during the break- and prevent smoking when the doors are opened. Check
in period. The temperature generated by these small fires may through the side or griddle door and move any wood or
not be high enough to sustain draft strength if the damper is coals leaning against the front doors before opening them.
closed. Maintain a small, lively fire. Avoid the extremes of a When using the stove as a fireplace, always keep the spark
slow, smokey fire or a very rapid burn rate. screen in place to reduce the hazard of flying sparks or
embers.
10
RECOMMENDATIONSWhen we designed these stoves we had in mind a hand-
some cast iron heater and fireplace unit. Although they will
All stoves behave differently; even a single stove will consume any combustible material, we do not really think of
react differently to different types of wood and chimneys. It will them as trash incinerators. Excessive amounts of paper and
take time to accustom yourself to your new stove and to its greasy or plastic materials may burn too hot, ignite a chimney
responses to various conditions. Remember, our Customer fire, or create a rapid build-up of ash. When using the stove
Service Personnel or Authorized Dealers are always a phone call to dispose of waste materials, treat it with common sense and
or letter away if you encounter a particularly perplexing problem. respect and be aware of what the stove was designed to do.
Listed below are a number of ideas that will help you get the
maximum benefits from your stove. The most exacting situation Wood: The drier the better. It takes heat to boil off the
occurs when the stove is used around the clock as the primary water in a piece of green wood. (There can be over a ton of it in
heat source. Although these suggestions are aimed primarily at a cord of green wood, or more than 250 gallons.) This lost heat
this usage, they should be helpful to all. is not recoverable and lowers intenal temperatures, reducing the
likelihood of secondary combustion. Split lengths of dense hard-
Do not add large amounts of fuel to a slow fire and woods should be dried under cover for at least eight months,
leave the setting low. This may smother the fire. Adding large though a year is preferable.
quantities of cold fuel to a slow fire is like asking an automobile to go Wood grows outward from the center in a series of con-
up a hill in high gear from a standing start. The bigger the centric cylinders or rings. When wood dries, water moves in
hill, the longer the running start you need. Allowing the fire the spaces between the cylinders ten times faster than it does
to build up heat is the running start. across or through the cylinder walls. This means that unsplit
wood dries only through the ends of the logs. Large and long
Firmly establish a strong fire before closing the logs should be split to expose the spaces between the rings in
damper and changing the stove to its horizontal combustion order to aid the drying process. It really does not help too
mode. It only takes a short time, and the increased efficiency is much to cut the wood and let it dry for a summer and then
well worth the trouble. A strong fire will increase turbulence, split it just before use.
giving a better gas/oxygen mix and allowing flames to lick under
the baffle, thereby assisting secondary combustion. Wood should not be cut too small, as this speeds up
A good bed of coals is necessary to keep the volatiles hot.as the gasification process and causes it to burn too quickly. if
they leave the primary combustion chamber. When you want to you are having trouble getting the stove to hold a fire for as
shut the stove down before going to bed or leaving the house in long as you would like, perhaps your wood is too small.
the morning, try to let the temperature build up first. Ideally, you Anything over twelve inches long and four inches measured
should load most of the wood thirty minutes before shutting the across the end of the log will do. The stoves work well with
damper. Then, top off the magazine just before shutting down as large a piece of wood as can be fit in. Irregular shapes with
the stove and adjusting your thermostat. Your stove will bum stubs of branches that hold the logs apart are not good, and
cleaner and give you more heat if you follow these steps. rotten wood is the worst. Burning and rotting are similar
chemically; so, in effect, rotten wood is partially consumed and
If you need more heat, remember that your stove is has already given up some, if not most, of its heat value.
truly a combination stove and will operate either in an updraft Under no circumstances should a piece of wood with ice or
or horizontal combustion mode. In its horizontal configuration, snow on it ever be put into any stove. The sudden thermal
only a limited amount of wood can actually become part of shock can crack the iron. Leaning an ice-covered piece against
the primary fire mass at any given time. This obviously the stove to melt the ice is also likely to cause damage. We do
reduces the amount of heat generated. If in extremely bitter not warrant our stoves against such abuse.
weather you need more heat, simply switch to an updraft
mode. All the wood in the magazine can now be incorporated
into the primary fire mass, thus producing more heat. Keep in
mind that the trade off made for this greatly increased output is —
increased wood consumption and shorter bum times.
Try to let the stove run fairly hot at least some of ice.
the time. If you find that your room seems too small to require
high heat, try using the stove as a fireplace with the screen in
position. A strong fire can be kept going at a high level with
just a couple of sticks of wood and will not become too hot for i^
the room. These practices will prevent too many deposits from
building up inside the magazine. Large accumulations of black
flaky deposits inside the magazine are a sign that the stove1
would be happier at higher temperatures and should occasionally
be run in updraft. ll
MAIN I ENA- NCE
ASH REMOVAL STOVE CLEANING
During constant use, ashes should be removed every few Some creosote production often occurs in air-controlled stoves
days, or when they have built up around the air distribution like the Defiant,Vigilant,Resolute and Intrepid precisely because
ports to noticeably affect operation. This is easily done when they are such efficient heat transfer devices. You must learn to
the stove has died down with only a log or so left, as in the watch for creosote, to control it, and to get rid of it.
morning. Improperly seasoned wood and excessive operation with
To empty the ashes, a few shovel scoops is all that is re- low, smoldering fires are two major causes of creosote produc-
quired. They may be taken from any door which allows good tion. Choosing the proper size stove for the space to be heated
access, even with a log or two still left within the firebox. is your best defense against creosote.
In order to achieve the high efficiencies which horizontal If the stove is oversized for its heating area, it will not
combustion offers, it is necessary to burn the primary fire mass have the opportunity to burn at a sufficiently high combustion
in as compact and hot a manner as possible. Burning logs rate. As mentioned earlier, the lower end burning rates are
lying directly on a good bed of hot coals, which in turn are less efficient, therefore more chimney deposits will be formed.
insulated from the cooling iron.of the bottom, is the best way A smaller stove operating at a higher burn rate will give better
to do this. Grates with relatively cool air circulating heat distribution, control and efficiencies than a larger stove
underneath, tend to disperse the high temperatures required by burning at too low a setting.
allowing coals to fall from the fire zone. Grates make it more NOTE: In the event that you should have a chimney fire, close
difficult to control oxygen flow to the fire mass. all the doors, the damper and the air intake shutter. Then call
your local fire department for help.
Some creosote deposits in the firebox of a horizontal com-
bustion burner are normal and require no attention as they
burn off when the stove is used as a fireplace or in updraft
configuration. During each heating season it is a good idea to
l \, remove the chimney connector periodically and inspect the
stovepipe and chimney for abnormal build-up. At this time it—
is also a good idea to touch the vacuum cleaner nozzle to each
distribution port and to the air inlets.
._: With a normal draft—unless the ashes in the firebox have
been allowed to build up too high around the ports—these
ports will be self-cleaning and require only an annual check.
CHIMNEY CLEANING
A wood-fired heating system requires maintenance of the NEW STOVES
whole system. Inspection of the chimney and flues should be
performed prior to every heating season and twice monthly New stoves should be carefully checked within the first month
while the stove is in use. The flaky, crusty lining of creosote of service.
deposits must be removed periodically. We recommend you • Be sure leg bolts are snug.
clean your chimney whenever inspection reveals the build-up • New gasketing may compress quickly at first. Handle adjust-
of creosote, Because this build-up is governed by the type of ment may be necessary.
wood burned, the manner in which you burn it, and the • Inspect chimney connector and flue for signs of creosote
characteristics of the chimney itself, there are no hard and fast build-up. Rapid accumulation of deposits in the stove or
rules as to how the chimney should be cleaned. Generally chimney system may indicate a need for changes in stove
speaking, outside chimneys will require more cleaning more operation.
often. Large flue sizes will require more attention than smaller • Inspect the whole chimney system to ensure all joints are
ones. Check the safety of your chimney during each inspection secure and tight.
and repair or replace damaged or worn chimney parts when • Check to see that glass panels or cast iron panels in doors
necessary. are secure. Snug up retaining screws if necessary.
If you clean your chimneys yourself, proper cleaning tools PORCELAIN ENAMEL
and safety equipment are essential.If you are at all unsure of your Clean your enamel stove with a cleaner specifically designed for
ability to do the job, we strongly recommend that you hire porcelain-enamel surfaces. Wipe any spills immediately, the cleaner
a trained chimney sweep. may damage brass trim or handles.
12
MAINTENANCESince each stove, installation and operation has its' own individual
GUIDELINES characteristics, no maintenance schedule can apply to all situations.
These suggestions can serve as guidelines while you develop your
maintenance program.
STOVE CHIMNEY & CHIMNEY CONNECTOR
• Check the ash level in the bottom of the stove. Clear the primary air ports in the fireback
and left side of the stove if they are blocked.Restrictions to the flow of combustion air may result
in a slow,inefficient bum.
C� • Be sure Air Inlet Shutter moves freely as you adjust the thermostat lever.
•Clean the area around your stove and be sure all tools and equipment are readily available. -
•During first months
O x of operation inspect the
W •Clean the glass panes in doors if necessary.Be sure glass is cool. Wipe up spills immediately.
chimney connector until you
learn the rate of soot accumulation.
cn
C •Check to be sure doors are closing securely. Gasketing becomes compressed over time. •Inspect chimney and connector, giving extra at-
Handle adjustment may be necessary. Preventing air from leaking into your stove will help tention to elbows and horizontal runs. Clean
f� 0 in giving you close control over the bum rate. when necessary.
•Thoroughly clean stove interior. •Thoroughly brush the chimney and connector to
•Check that all controls work freely. remove all ash.
•Remove chimney connector and clean baffle system between fireback and back of stove. •Inspect the chimney and chimney connector for
•Replace gasketing and firebricks(Intrepid only).as needed. any signs of deterioration.Have a professional mason
od •Clean dust off all heat shields. repair the chimney. Replace chimney connector sec-
c¢ct •Check stove seams, and re-cement if necessary. tions if any appear to be corroded.
>" •Re paint the stove.
•Lubricate handle shafts.
INTREPID MAINTENANCE
Under normal firing conditions, soot or fly ash may accumulate
in the bottom of the secondary combustion chamber. These
deposits should be removed periodically to insure proper air flow
through the stove. Clean the chamber when you clean your
chimney flue and stovepipe. We suggest you inspect the chamber
once per month until you determine how quickly build-up occurs.
Access to the secondary combustion chamber is gained from
the inside of the stove with removal of the upper fireback.
Loosen the two 5/8" acorn nuts on the outside of the back plate.
The fireback weld screws can then be turned and the fireback removed. CORRECT FIREBRICK PLACEMENT-CROSS SECTION.
Disengage the damper from the damper rod and remove the
two vertical firebricks. Be Certain The Stove Is Com-
pletely Cold Before Removing Ashes. _
When you replace the two vertical firebricks, be sure they are UPPER FIREBACK
positioned as shown. ^I STOP
Engage the damper with the damper rod and set the damper TAB ScaE°
flat on the firebricks. Tilt the upper fireback into position, keep-
ing the brick retainer bar behind the front firebrick. As you push —� _ DAMPER TAB
the upper fireback against the rear plate of the stove, the back 1,
edge of the damper must be above the stop on the back of the stove.
Turn the weld screws back over the fireback tabs and retighten BRICK RETAINER BAR DAMPER
the acorn nuts on the back of the stove only until snug. HINGE PIN
DETAIL OF THE UPPER FIREBACK
13
HANDLES & LATCHES QUESTIONS & ANSWERS
The insert handle is designed so that you will always have a The stove does not hold a fire as long as you would like:
cool handle with which to operate your stove. Extra ceramic Check the thermostat adjustment. When the stove is warm
parts and bolts are available in case of damage to the assembled
handle. (too hot to touch, but not overly hot) move the thermostat lever
designed to permit easy ad to its lowest setting. Does the Inlet Air Shutter close? If not, then
Thy door latches were carefully
adjust the ball chain at the bottom down a ball or two and try
justment, ensuring an airtight fit over the years. We have in-
cluded a 118-inch Allen wrench to help you. After a period of again.
Perhaps your wood is too small in diameter or too short, as
time the gasketing may compress and you will want to tighten
the latch mechanism. Loosen the small locking nut on the was mentioned earlier, and the charge is just burning too quickly.
striker screw. Tighten the screw a turn or two with the small Burning soft woods such as pine will significantly reduce the burn
time because they will combust at a more rapid rate than hard-
Allen wrench, and retighten the locking nut. The large lock- wood. Maximum bum time is achieved by burning hard wood
ing nut holds the pawl on the shaft and should not require
any adjustment. cut to proper length.
Did you remember to close the damper and adjust the ther-
SMALL LOCKING NUT mostat? It is very easy to forget these two things.
STRIKER SCREV Check the gasketing. Perhaps a piece of charcoal has dislodged
or compressed the gasketing so that the door has lost its seal. In
time the door latches will need to be tightened.
LARGE LOCKING NUT It is possible (though it happens rarely) that you have ex-
HANDLE sHAFr ® cessive draft. This usually occurs with a tall interior masonry
chimney that is located so that prevailing breezes constantly blow
across the top, as in the case of a house located high on a hill or
PAWL near the shore. Should this prove to be the case, first experiment
SET SCREW with closing down the secondary air control slightly. Easy does it
here. A 30 percent closing is probably all that it will require. In
A large Allen wrench (5/32 inches) is included in the De- extreme cases, try installing a flue damper to partially restrict the
fiant and Vigilant to allow you to tighten the damper handle draft.
should it work loose after extended use.
The stove smokes as a fireplace:
GASKETS chimney
deposits may have built up in the stovepipe or
and are restricting the draft. Remove the pipe and clean.
Gaskets in good condition provide a seal around the doors Is there another stove or heating device on the same flue? An oil
and griddle opening of the stove. If over a period of time you furnace is open vented and the draft may be pulling air from the
notice that the gaskets have become worn or frayed they basement rather than through the stove. If your stove is con-
should be replaced with Vermont Castings brand gaskets. netted to a chimney with a fireplace on the same flue, make sure
the fireplace dampers are closed or the opening blocked off to en-
sure a strong draft.
GLASS DOORS
How tight is your house? Sometimes new homes are con-
Depending upon the mode of burning and rate of burn,carbon strutted and insulated so effectively that a sufficient volume of
deposits may form on the inside of the glass. Hot, updraft fires oxygen is not available for the burning process. Try opening a
help keep glass clean, while slow horizontal fires are likely to window a crack. If this solves your problem, then you know
cause soot to form. It is important that the glass be completely your house is too tight and outside air will have to be in-
cooled as any cleaning agent applied to hot glass may per- troduced.
manently etch it. Once the glass is cool, any common glass In moderate weather establish a strong fire with the front
cleaner will do the job. Remove all traces of cleaner and dry doors closed, then open the front doors to the fireplace mode.
the glass before firing the stove. if the glass is ever damaged, This will prime the chimney to maximize the draft.
replace it immediately with Vermont Castings high temperature Back Puffing:
glass which is specially designed for safe stove operation. In the spring you will notice your draft is less strong. If
Some glass cleaning agents may discolor porcelain enamel sur- you experience back puffing during unusual weather condi-
faces, so wipe any spills immediately. tions, this usually means that you have temporarily lost the
chimney draft. To regain a positive draft open the damper and
adjust the thermostat to the open position. This condition can
.�.1. be prevented by closing the secondary air control and leaving
' the stove on updraft. Cold weather back puffing usually is a
result of gusts of wind and can be partially avoided by the use
of a chimney cap.
14
STOVE DIMENSIONS
The following elevations indicate dimensions which will enable you to plan your installation as accurately as possible.Variables inherent in
the manufacturing process can result in differences of up to 3/8"between these dimensions and those of your stove.Be careful to plan stove
placement so as not to restrict the side loading access to the Defiant or the top loading access to the Vigilant,Resolute,and Intrepid.
Some installations,such as into a low fireplace,will require a reduction in the height of the stove.By substituting short legs for the standard
length legs,the height of each stove can be reduced as indicated. 22"
.341h" 1a" 8"Oval Flue Collar
m 3"
Defiant
Short legs reduce the height of the
Defiant by 4t/,". 335/e 28 518"
Top
Exit UI
T
7%"
35" � �- —19t/4
281/4" 23" 8°Oval Flue Collar
�191h
vigaant 0
303 vrl//
Short legs reduce the height of the Top
� � 28 5/8"
Vigilant by 04". Exit
T
7t/a'
1
— 293/4"—� —20"---�
251/4" 22" 6"Slightly Oval Flue Collar
r-17" 1
® 23/4"
Resolute
2ati," LM
Top 221/2"
Short legs reduce the height of the Exit
Resolute by 3".
�.--263/4
211/4
11
18 A_ 6"Round Flue Collar
® —3„
Intr 1
25'
Top
Exit 203/4"
Short legs reduce the height of the
Intrepid by 4". 7 e
� J 15
21"--, ---133/4"—j
WARRANTY • FOR USE IN THE U.S.A.
LIMITED 3 YEAR WARRANTY
Vermont Castings, Inc. warrants that your stove will be free of defects in materials and workmanship for a period of three years from the
date received except that the catalyst,thermostat assembly, handles,glass door panels, gasketing, coal grates,coal linkages, and coal magazine
throat shall be warranted as described below.
Vermont Castings, Inc. will repair or replace at its option, any part found to be defective when the stove is returned to an authorized
Vermont Castings service center. The customer must pay for the return shipping or any transportation costs for returning the stove.to the
authorized service center.
If,upon inspection, the defect is found to be the fault of the manufacturer, repairs will be authorized at no charge to the customer for parts
and labor.
Any stove or stove part,other than the catalyst,that is repaired or replaced during the Limited 3 year Warranty will be warranted for a
period not to exceed the remaining term of the original Limited Warranty or six (6) months,whichever is longer.
LIMITED 1 YEAR WARRANTY
Parts subject to normal wear&tear
With the exception of the catalyst(which is covered solely by the Catalyst Warranty below),certain parts of the stove which are subject to
normal wear& tear are warranted to be free of defects in material and workmanship for a period of one year from the date you receive it.
Examples of such parts include the thermostat assembly,handles,glass door panels,gasketing,coal grates, coal linkages, and the coal magazine
throat. Any such parts found to be defective will be repaired or replaced at no charge,upon the return of said part to an authorized Vermont
Castings service center with postage prepaid.
CATALYST WARRANTY
(For Defiant Encore""only)
The catalyst will be warranted for a six year period as follows:
If the original catalyst or replacement catalyst proves defective within 24 months from the date the stove is received, the catalyst will be
replaced free. From 25.72 months a pro-rated credit will be allowed against a replacement catalyst.The purchaser will be liable for the
difference in cost between the credit and the retail price of the catalyst at the time of replacement.
AMOUNT OF TIME CREDIT TOWARD
SINCE PURCHASE REPLACEMENT COST
0-24 months 100%
25.36 months 50%
37.48 months 30%
49-60 months 20%
61-72 months 10%
Any replacement catalyst will be warranted under the terms of the catalyst warranty for the remaining term of the original warranty.The
purchaser must provide the following information in order to receive a replacement catalyst under the terms of this limited warranty.
1. Name, address, and telephone number.
Z. Proof of original purchase date.
3.Date of failure of catalyst.
4. Any relevant information or circumstances regarding determination of failure.
In addition, the owner must return the failed catalyst with shipping charges prepaid to an authorized Vermont Castings service center.
EXCLUSIONS AND LIMITATIONS:
I.The warranty is transferable. However, proof of original retail purchase is required.
2.This warranty does not cover misuse of the stove. Misuse includes overfiring which will result if the stove is used in such a manner as to
cause one or more of the stove plates to glow red. Overfiring can later be identified by warped plates and areas where the paint pigment
has burned off.Overfiring in enamel stoves is identified by bubbling,cracking,chipping,and discoloration of the porcelain enamel finish.
Porcelain enamel parts are subject to bubbling,chipping,cracking, crazing and discoloration when subjected to abnormally high temperatures
or thermal shock. Vermont Castings offers no warranty on porcelain enamel surfaces subjected to these conditions.
3.This warranty does not cover a stove which has been the subject of other than normal repairs by an authorized Vermont Castings service
center.
4.This warranty does not cover any modification to the design of the stove unless authorized by a Vermont Castings representative in writing.
5. Damage to stove while in transit is not covered by this warranty but is subject to a claim against the carrier.(Do not bum the stove as
this may negate the claim with the carrier.)
6.This warranty does not cover claims involving stove installations that do not conform to local building and fire codes,or to the
recommendations in our Operation Manual.
7. Vermont Castings shall have no obligation to enhance or update any unit once manufactured.
IN NO EVENT SHALL VERMONT CASTINGS BE LIABLE FOR INCIDENTAL AND CONSEQUENTIAL DAMAGES. ALL
IMPLIED WARRANTIES,INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS ARE LIMITED TO
THE DURATION OF THIS WRITTEN WARRANTY.THIS WARRANTY SUPERCEDES ALL OTHER ORAL OR WRITTEN
WARRANTIES.
Some states do not allow the exclusion or limitations of incidential and consequential damages or limitations on how long an implied
warranty lasts, so the above limitations may not apply to you.This warranty gives you specific rights,and you may have other rights which
vary from state to state.
HOW TO OBTAIN SERVICE:
If a defect is subject to warranty,the purchaser should contact the nearest Vermont Castings Authorized Dealer with the following information:
1.Name, address,and telephone number of purchaser.
2. Date of delivery and place of purchase.
3.Serial number from the back of the stove.
4. Nature of defect or damage.
5. Any relevant information or circumstances,i.e. insulation, mode of operation when defect was noted.
Vermont Castings reserves the right to withhold final approval of a warranty claim pending a visual inspection of the defect by authorized
representatives.
Vermont Icas�ings
T77)
7
1001000000000ooaoaoaoAo 0000a00000a a��
IDefi Vn.-g�lat Reso�u�e
aid
i—t -.e I.�
;' �1ooc4 Parlor Moves
..A Philosophy ,.A Committi �nt
"We 5uild wood stoves because we believe there are`sensible ways to heat our without aus homes exhting
precious oti.supplies:Vermont;Cwings:was founded on.this philosophy and tt continues to guide us today
When_,wp began;Makin stoves, wood was our firsr:cl oice as-an alternative to_heating with oil .The chemical
reaction that occurs within the leaf is:the only known natural exchange th"at can store the sun's energy In every
sense, wood'lreat us a loan from the;sun B we:fail to,use is to warm ourselves, tvood~lreat�vill.eventually be.consumed;;
=_by.rot, and;:decay into the a.mix lie(can is bhefr not much longer than th4;;span of`a human life We`:
encourage you,through the ownership:of our stoves, to take this:loan and use u wtsety for:your benefit and pEeasure
If we are careful in the harvesting of wood,our forests wig supply:us with a lasting supply of fuel `
While wood is,"our_anly:renewable:fuel sourice, coal is;'one,:of Amenca'a'most abundant resources. For many
persons�espeaally our urbaiv: nds,:t d>fftc41 to find`a ready:supply of'.wood Recog<rtzing thts,'we recently.''
introduced a opal bumtng stove, and.a�eoa(cotrver�on unit for existing wood stoves
owncoal reserves can:meet ours heating needs for years to come But; as stewards of the earth we mtisr:'abide
by-an ethic at,mandates.we bum coal as sparingly and efficiently as possible By doingso, we ensure that there will
be ample supplies o coal to•warmttfre:homes of'irture getlerations '.
As responsible users of'one of the.earth's natural resources, we =not ignore pollution problems i ated io'the .
burmng of°coal We made our stoves to be as efftaent as';possible and designed`them.to bum:.premium.gra
atithraate,.the least'pollutrng of any,of.the coaltypes We suggest.you cheat the availability of tfus cgal fn your.area '
before making a decision to.'6um with coif •. :' ` ;' ,.-
Buying awood or coal stove,espeaally I'highly sophisticated gne ltice ours,is a:comnutment -s the owner of one
of:the finesr stoves`tirade,you:.have ziade a commitment toward'a lfesryle founded in the t►oilan that:one technology ;
does not.replace another,bpi'allows i s to become reconnected to..the natural sysfetns which support us; )n doing so < '
you acquire:anew yvoarbulary This operation matttiar summa6b our knowledge Combined with your.effort,i will
provide the mformaaon you;fieed to leach your:goals We at Vermont.Castings feel::zhat your commitment;to.your
new stovee!..rt some;cases a very new 6-Mir ce,w�l:be .amply awarded
10
How To Manual
This rttarival roatalns a great deal of mformatton and is no `easily digested to one st.4og $efore you tight your
first Ere, read it thoroughly; espectally..:the Operations instructions Otherwise you;might damage y9uc stove Read tt
-again after'the stove:Gas been,in service.or a while Many of the difficult co;unders(and points w►ll become clear*..If you ;
have specific questions aboutahe mstallanotrof,your stove;and tlie..dearances necessary for safe operation,please contact,
your Auihorized'Dearer or.our Cu�to rier SeMkii-Mpamuent:We have:an insfallapon guide arid-other technical
nformation available to help answer your questions We will be happy'to discuss':,v pamcular-problems:'
f +
1 .
�h. ` 11 � �{I�17 �����yl•�I
�� —r i- a �n ., r'►':. {{�,{ �'i `�
WELCOME
As a Vermont Castings' stove owner, you join a unique community of persons dedicated to using alternate
energy sources. Whether or not this is your first experience with wood or coal, you are assured of our continued
support and guidance to help you gain the maximum benefit and enjoyment from your new stove.
This special relationship is extended to you through our Vermont Castings Authorized Dealers, our Customer
Service Department and the Owners' News. Vermont Castings people are well versed in every aspect of heating
with wood and coal. Periodically you will receive copies of our Owners' News. Your first copy was packed in your
stove. In it we provide helpful hints which will give you the benefit, not only of our experiences, but those of
other customers as well. Please take advantage of the Owners' News to share secrets you discover with other stove
owners.
It has always been the philosophy of Vermont Castings to maintain direct contact with our customers. We hope
to learn as much from you as you learn from us. If problems do occur, we can draw on the experience of
thousands of stove owners to help you. Very few manufacturers have this advantage, an advantage which becomes
yours when you purchase your Vermont Castings stove.
We have tried to make this manual as easy to read as possible. We urge you to familiarize yourself with it
before setting up your stove. Familiarize yourself with the parts of the stove and their functions so that it will be
easier to understand the information in the manual. The clear chapter headings should facilitate your task. Read
the chapters in order. If you have already completed your plans and the work necessary for installation, you might
like to move ahead to the chapter on setting up the stove. Once again we caution you to please read through the
material at least once before you make the final installation connection and build your first fire.
INDEX SAFETY NOTICE:
IF YOUR DEFIANT,VIGILANT,RESOLUTE OR IN.
TREPID IS NOT PROPERLY INSTALLED, A HOUSE
2 The Inside Story FIRE MAY RESULT. FOR YOUR SAFETY, FOLLOW
THE INSTALLATION DIRECTIONS. CONTACT LO.
6 Installation CAL BUILDING OR FIRE OFFICIALS ABOUT RE,
STRICTIONS AND INSTALLATION INSPECTION
10 Operation REQUIREMENTS IN YOUR AREA.
12 Maintenance
AJ-
a
THE INSIDE STORY
Economics & Efficient Combustion
The How & Why Fuel Limiting:
It has been our experience that if you understand the inner There are two ways to control the volume of power output in
workings of your stove you will be better equipped to use your a combustion device: fuel limiting and oxygen limiting. An
stove wisely and to gain maximum savings and pleasure from its automobile is fuel-limited. If you need more power, you supply
daily use. That is why this section on the efficiency and com- the engine with more fuel. If you make an uncontrolled amount
bustion principles of the stoves is included before you reach the of gasoline available to the spark plugs at once, the engine
installation information. becomes an inefficient source of power.
Our four stoves share the same design and combustion prin- An updraft stove places the entire fuel supply in the combus-
ciples. The Intrepid differs a little in interior arrangment and air tion zone at once. If the fire is partially smothered to control
flow patterns. Intrepid owners, see The Intrepid, page 5. the rate of the burn, thick smoke and low efficiencies may
Let us start your tour of the inner workings of the stoves result. Our magazine system uses no more than the amount of
with a discussion of horizontal combustion, a fundamental concept fuel necessary in the combustion zone at any one time in order
behind the operation of our wood stoves. In horizontal combus- to produce the maximum amount of heat for which the stove
tion, the flames move horizontally as they leave the primary was designed. In order to slow the fire below these points, we
combustion zone. Many stoves employ updraft combustion, in use oxygen limiting with an automatic thermostat which provides
which flames rise up through the fuel load. All wood loaded in- the fire with an apropriate level of oxygen.
to an updraft stove becomes part of the fire mass unless oxygen
is restricted to a low level. Our horizontal flamepath allows only
the bottom of the wood load to burn. The logs on top are dried
by heat and fall into the flame area as those below are consum- Air Control Systems
ed. Thus, a full wood load can provide heat all night long.
The use of horizontal combustion allows for us to place the Primary Air Systems
fuel in a magazine where the fueling of the fire is automatically In both our wood and coal stoves, oxygen enters.at'the ther-
accomplished by gravity. mostatically controlled Inlet Air Shutter and travels through
The horizontal combustion mode will be used by most wood passages where it is heated before being fed to the fire mass
burners under normal conditions as it will ordinarily produce through the Primary Air Ports.
more usable heat in the room per pound of wood loaded into When a fuel is heated and bums, the.volatile combustible
the stove than the updraft mode. However, where there are gases naturally locked in it are driven off. In an updraft combus-
special conditions to be met, low draft, a need for extra heat in tion stove or fireplace, these volatiles may be left unburned for
extreme weather, or an unseasoned wood supply, for example, two reasons. First, by the time the gases have left the fuel, they
the updraft mode may serve you better. Our stoves are combus- are too cool to ignite. Second, the oxygen that enters the stove is
tion controlled (sometimes called "air-tight") in either mode. usually consumed by the glowing coals at the base of the fire
Burn rate and heat output may be controlled by adjusting the mass, so the gases rise through an atmosphere too deficient in
thermostat lever. oxygen to allow combustion to take place. The loss of volatile
gases is serious in the case of wood, for it represents approxi-
mately half the total heat value.
Secondary Air Systems
J Our stoves facilitate the burning of these volatiles in several
ways. By using horizontal combustion, the gases are forced to pass
close to hot coals which maintain a sufficiently high temperature
(as high as 1200' Fahrenheit) for ignition.
Our stoves also employ a sophisticated system which intro-
duces another source of preheated air (secondary air) to encourage
combustion of these volatile gases. The secondary combustion of
gases that, because of an insufficient oxygen supply, were unable
to ignite within the primary combustion zone, are encouraged to
release their heat. Secondary air treatment of the coal stoves is
Horizontal combustion Updraft combustion different because of the individual characteristics of coal and wood.
2
The inner workings of the Defiant C Secondary combustion
chamber.
Heat-regulating thermostat. Allows unburned gases to com
Automatically controls air intake t c bine with oxygen, providing
to assure steady, even heat all
additional heat.
day, all night long
The baffle.
Creates a longer flamepath for
Two-position damper. maximum heat transfer.
Permits use as fireplace; or when 1
adjusted, helps provide maximum
heating efficiency. 1
Secondary air tube.
Feeds preheated oxygen to
secondary combustion chamber.
Secondary Air Cover. �-
Allows air to enter
the secondary air tube
and become preheated
as it passes behind
the fireback. The Smoke shelf.
cover should remain Directs spent gases into upper
open when burning chamber, where they release
wood, additional heat before rising up
flue.
Primary air entry ports.
Disperse preheated air evenly
into combustion zone.
Thermostat Control
The thermostat lever at the back of the stove controls the THERMOSTAT OPERATION
Inlet Air Shutter, and thus the amount of air entering the stove •View of thermostat for Defiant and Vigilant is with thermostat cover removed
•Resolute bimetallic coil is revered
for combustion. Attached to this lever is a bimetallic coil which
contracts or expands to the heat given off from the stove. A THERMOSTAT —
ball chain connects the lever to the air inlet shutter, thus regu- LEVER
lating the flow of incoming combustion air. As a result the THERMOSTATCLIP
}
stove's heat output intensifies and the air supply is decreased. BIMETALLIC
The combustion rate slows, heat output drops, and the air COlt. 8
s
supply is again allowed to increase as the bimetallic coil BALL CHAIN�~
reopens the air intake shutter. AIR INTAKE
The thermostat lever can be set to accommodate your indi- SHUTTER
vidual heating requirements. The overall heat output throughout a.After fire is h.As heat output c.As heat output
the bum period is determined by the lever setting. The length of well established, intensifies lowers.air intake
set thermostat air intake increases.
bum Is similarly related to the lever setting as a high heat output to desired is decreawd.
will necessarily allow faster fuel consumption than will a lower heat output.
IR
heat output setting. The most efficient use of the stove and fuel 41R AIR TA
INT:IKE INTAKE INTAKE
can be made by setting the thermostat to allow a moderately hot SHUTTER SHUTTER SHUTTER
fire. Lung, smoldering bum periods should be avoided. HALF OPEN CLOSED HALF OPEN
3
YOUR WOOD STOVE The considerable heat of the flue gases is transferred to the
surface of the stove, where in turn it is given off to the room,
The Internal Parts & How They rather than being lost up the chimney. Secondly, because the
Contribute To Efficient Operation passages are adjacent to the combustion chamber, higher tem-
peratures are maintained within the fire mass itself, which aids
Secondary Combustion Chamber in the burning of the volatiles. It can easily be seen that unless
the flamepath is concentrated tightly within the stove, the heat
Secondary air enters our wood stoves at the lower left of the flue gases will not contribute to the temperature of the
end of the stove through.the circular Secondary Air Entrance primary fire mass, nor will the gases maintain their necessary
Port. Under normal conditions, this remains open all the way at high temperatures in order to ensure combustion of the volatiles.
all times. This air passes down the Secondary Air Tube where it
is preheated. The air supply is then directed into the Secondary The Damper
Combustion Chamber through numerous air ports, so that it The damper is the last of the important-internal pans. In its
can mix with and ignite the combustible gases. A Secondary vertical or up position, the damper is closed and flames exit from
Combustion Chamber allows the gases to expand as they are the stove by way of the long flamepath described, allowing the
further heated by their own combustion. A large portion of the horizontal combustion mode. When lowered flat, the damper is
stoves exterior surface encloses this chamber, thus allowing for open and the stove is converted to an updraft combustion device,
transfer of the maximum possible amount of heat to the room. allowing flue gases to escape directly from the magazine into the
Behind the Fireback are the smoke passages. These passages chimney connector. (The various requirements of the two func-
consist of a series of Baffles that conduct the flue gases in a tions are explained in the section titled "Operation.") It is impor-
serpentine manner back and forth across the length of the tant to note the relation of the handle to the damper. On the
stove. The gases are channeled close to the thermostat coil in Defiant and Vigilant, when the damper is closed, both it and the
order to give it maximum sensitivity to the changing fire condl handle are vertical. On the Resolute, the spirally wound wire
tions within the stove. The back of the Vigilant and the back handle is down when the damper is closed and up when it is open.
and sides of the Resolute have been deeply convoluted, like old Smoke will come out of any opened loading door if the dam-
Victorian steam radiators, to provide a large surface of cast iron per is closed. The interlock with the damper handle and the
exposed to the room, ensuring a good radiating surface. loading door on the Defiant is designed to prevent opening the
The Flamepath door while the damper is closed. The griddle of the Vigilant will
not open all the way should you forget to lower the damper first.
The Secondary Combustion Chamber, taken together with the These serve as reminders that you can only load wood smoke-
smoke passages, make up the flamepath. lessly when your stove is in an updraft configuration and the
The Defiant's sixty inch flamepath is one of the longest of damper is in the open position. The section on Operation
any cast iron stove currently on the market. The Vigilant flame- will explain the proper steps to take before closing the
path measures fifty-five inches; the Resolute fifty inches. A long damper when you use the horizontal burning mode.
flamepath is important to the heating capability for two reasons.
t2 2
r J
6 4
3 � � m
THE VIGILANT
0
THE DEFIANT 1.Thermostat 6.Secondary Air Tube
2.Damper 7.The Baffles THE RESOLUTE
3.Secondary Air Entrance Port 8.Reversible Flue Collar
4.Primary Air Ports 9.Top or Rear Exit Model
5.Secondary Combustion Chamber
4
gTHE INTREPID
The Intrepid is designed with several features that differ from our 5 Air Flow
three larger parlor stoves. Air flow patterns, ash removal
and maintenance procedures specific to the Intrepid are described
here.Basic combustion principles remain the same for all four stoves,
so the operation and installation sections of the manual apply {;
equally well to the Intrepid. X. ,er,?'
Air Flow
Glass doors for fire-viewing are a standard feature in the
Intrepid. Air flow through the stove is designed so pre-heated
air washes past the glass to prevent carbon deposits from forming.
Combustion air enters through the air inlet in the back of the
stove, passes forward through the air tubes at the left and
right sides of the bottom of the stove and flows past the glass. rl
Some of the air goes directly back through the fire mass and J
provides air for combustion in the primary combustion zone.
Excess air flows over the fire mass and contributes to further com- THE INTREPID
bustion.
1.Thermostat 5. Reversible Flue Collar
Damper Open Operation z.Damper 6. Bottom Grate
3.Air Ports 7. Ash Pan
When the damper is open(handle pointed forward)the stove is in 4.Firebrick-Lined Secondary
the damper open mode. Fire and smoke leaving the primary com- Combustion Chamber
bustion zone go directly to the flue collar and chimney con-
nector. These exhaust gases carry heat to the flue. A warm
flue is helpful in establishing and maintaining good draft. Updraft
operation will be used when starting a fire, loading your stove, or When you replace the ash pan in the Intrepid,be sure it is seated
enlivening the fire after a long bum. It may also be used any- properly and pushed all the way to the rear of the stove
time a warmer flue will provide better performance. so it does not block the front ends of the air tubes. Too much
ash on the bottom of the stove may prevent proper seating
of the ash pan.
Damper Closed Operation
When the damper is closed (handle pointed down) the stove Fireplace Operation
is in the damper closed mode.Fire and smoke leaving the primary With the stove damper in the open position, and
combustion zone are directed through the louvers in the Upper the front doors open, a wood stove may be used as a fireplace.
Fireback, down through the firebrick-lined secondary chamber It is ideally suited for those times when you do not require a great
then to the flue collar and chimney connector. The high deal of heat output such as in the spring and fall, or when you
temperatures maintained in the secondary combustion chamber want to enjoy the romance of a crackling fire. Always keep the
encourage further burning of volatile gases in the smoke. sparkscreen in place when the doors are open.
Horizontal operation will usually be used during extended burns.
Ash Handling Thermostat Function
Slots in the bottom grate allow ash to fall through into the ash Whenever the front doors are closed, all air entering the stove
pan. Slicing the ashes on the bottom grate with the slicer/poker is regulated by the air intake shutter which is linked to a bimetallic
will help the ashes fall through the slots. thermostat coil and lever at the right side of the flue collar. Push
Empty the ash pan once a day or as necessary to keep the the lever back to admit maximum air for hotter fires. Pull the lever
ash pan from overflowing. Use the hook on the end of the slicer/ forward to reduce air and slow the combustion rate.The bimetallic
poker to pull the ash pan part way out of the stove. Wear coil and,consequently,the air intake shutter,continually open and
heavy gloves as you draw the pan out of the stove and dispose of close in relation to temperature fluctuations within the stove to main-
the ashes properly. Your metal ash container must have a tight- tain an even heat output. Generally, the lever should be kept in
fitting lid and be located outdoors, away from any combustible medium to high setting. Very long,smouldering wood fires should
material. be avoided.
5