Loading...
HomeMy WebLinkAbout32573-Z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-32505 Date: 08/06/07 THIS CERTIFIES that the building NEW DWELLING Location of Property: 1895 MINNEHAHA BLVD SOUTHOLD (HOUSE NO.) (STREET) (HAMLET) County Tax Map No. 473889 Section 87 Block 3 Lot 53 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated NOVEMBER 27, 2006 pursuant to which Building Permit No. 32573-Z dated DECEMBER 15, 2006 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ONE FAMILY DWELLING WITH COVERED PORCHES, COVERED BREEZEWAY, ATTACHED TWO CAR GARAGE AND SECOND FLOOR BALCONY AS APPLIED FOR. The certificate is issued to LARRY B & JOAN M KULICK (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL R10-06-0053 07/12/07 ELECTRICAL CERTIFICATE NO. 126656 07/25/07 PLUMBERS CERTIFICATION DATED 07/23/07 DENNIS FRANKS Authorized Signature Rev. 1/81 Form No.6 TOWN OF SOUTHOLD _ BUILDING DEPARTMENT TOWN HALL 765-1802 AUG - 2007 APPLICATION FOR CERTIFICATE OF OCCUPANC This application must be filled in by typewriter or ink and submitted to the Building Depart ex�tih-Elie=follotivi:ng:'? A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied; the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$25.00,Additions to dwelling$25.00, Alterations to dwelling$25.00, Swimming pool $25.00, Accessory building$25.00, Additions to accessory building$25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00 Date. j, 2-(2 2 New Construction: `/ Old or Pre-existing Building: (check one) / Location of Property: House No. Street Hamlet Owner or Owners of Property: LToo 4 /9 x 1`r./ Suffolk County Tax Map No 1000, Section ° Block 0 3 Lot Subdivision Filed Map. Lot: Pemlit No. Date of Permit. j�p/," Applicant: Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ rZ 0-(3 �3 Applicant 8iKature � . LONG ISLAND ELECTRICAL INSPECTION SERVICES, INC. 670 MIDDLE COUNTRY ROAD Application No.: 126656 Permit Number: 325732 ST.JAMES, NEW YORK 11780 (631)265-3075, Block: 0003 Lot: 053 Fax(631)265-6057 Section 087 agent: Triangle Electric. Ovimer`� `. Kulick Residence Address: Post Office:.Box,:#61 ' Address:` '1 -9 Minnehana Blvd. Municipality:Southold NY St. James NY 11780 P ty: License#: trian OwnerPhone Agent: 'No. 4TEM' SIZE No. ITEM 'SIZE No. 'ITEM; �SIZE 47 Switches: 0 SubFeeds: 0 PoolsAbvBlo: 61 Receptacles 0 Timers: 0 PoolslnGround: 8 GFCI Devices: 2 !Transformers: CL II 0 Pools Filter: 0 Dimmers: 3 .ACEquipmentCentrak 30,20,20 0 Pools Lights 67 MediumBaseFixtures: 0 IACEquipmentWindow 1 CO Detectors: 0 iFluroescentFixtures: 0 VotorsbyHP: 0 Disposal -_ - -0 1HID 0 ;Generators: 0 Metal Halide Lamps: 1 'Ran geOvenCookTop`: 40 A 1 ;WhiripoolHotTub: 1 Refriggnits: 1 DryerElectnc 30 A 1 ;.Microwave: 0 iWalkrnBox: _. _ 4 ExhaustFans: 0 WaterHeaterElectric: 0 ExhaustUnit 0 . 5te 6 CeihngFans. 6 SmokeDetectors: -; amShower., 1 DW. 0 TrackLightmgStriP 0 treadWarmers 1 0 ...ElectricHeat 0 , ;GarbageDisp sLaundry. 1 HeatingEgwpMotors. 0 PumpMotor: 0 CentralVac: 0 1,Exitsigns: 3 Disconnects:, 0 ChandelrerLifts . ___. .._. . . . 0 EmergencySigns: 4 iFutureOutiets: 0 ElevatorLifts. -- LOCATION OF WORK: ❑Basemen', ❑d FirstFloor W ;SecondFloo., 0 Outside: ❑ Addition ❑'Survey ❑d ,New Const. Comments ;New Residence Final 7/25/07 L Temporary El OH ❑ UG W Amp: 200 Phase: 1 Volts: 240 WireType:AL Conductor 4/0 -# Meters:__.1 Member I.A.E.I. Electrical Certificate Certificate No. 126656 LONG ISLAND ELECTRICAL INSPECTION SERVICES, INC. THIS CERTIFIES THAT R LO AL DISTRICT Certificate Issued on: 7/25/2007 INSPECTOR CONE D AN I SP TION OF THE Issued to Kulick Residence VISIBLE PORTION HE ELE IC L INSTALLATION S [BED HE EIN ND IS Address: 1895 Minnehana Blvd. COMPLIANT HT E CURR T N TIONAL Southold NY ELECTRIC CODE Triangle Electric I Post Office Box #61 IAEI Certified Inspector St. James NY 11780 1 o� Gyp y Z Town Hall,53095 Main Road P.O..Box 9 Oy �.F Fax(631)765-9502 Southold, New Yorkk 11971-0959 �O� �aQ Telephone(631)765-1802 BUILDING DEPARTMENT !1 TOWN OF SOUTHOLD JUL 2 3 21 1 hvi 1i1�. yp,n 1. CERTIFICATION Date: 71,0 k "7 Building Permit No. .3a S 73 7— Owner: Kyi--I LI( 1-41RR Y JOA IJ (Please print) Plumber: (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. (Plumbers Signature) Sworn to before.me this day of 200- Notary Public, County BEATME E.GALLO Notary Public State of NowYetk NoT Tenn �9�Aril 2f1(,20LL FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 32573 Z Date DECEMBER 15, 2006 Permission is hereby granted to: LARRY B & JOAN M KULICK 21 TORLEN COURT HAUPPAUGE,NY 11788 for CONSTRUCTION OF A NEW SINGLE FAMILY DWELLING WITH ATTACHED ACCY GARAGE WITH WRAP AROUND PORCH AS APPLIED FOR; FLOOD PMT INCLUDED at premises located at 1895 MINNEHAHA BLVD SOUTHOLD County Tax Map No. 473889 Section 087 Block 0003 Lot No. 053 pursuant to application dated NOVEMBER 27, 2006 and approved by the Building Inspector to expire on JUNE 15, 2008 . Fee $ 1, 274 . 80 Authorized Signature ORIGINAL Rev. 5/8/02 OF SOUryOlo Z • yo TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ FINAL A ,' [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: S DATE 7��� INSPECTOR �'�� � Of SOUIyo`o 7-3 # # TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING KFINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: / �fl P DATE INSPECTOR OF SOUlyo�o TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND PONSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ]rFIRE RESISTANT PENETRATION REMARKS: � - Lj i jr 1 �l DATE �� r INSPECTOR SOUjyo�o 3p-s-73 TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST K ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION ;FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: r DATE l �� ® / INSPECTOR � ' ;73 pF SOU TOWN OF -D-B G DEPT. 765-�1802 INS lEC- TION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. FO DATION 2ND [ ] INSULATION FRAMING[ STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: ��� c DATE 101 INSPECTOR SO(/l�°lo a-�73 Comm,��' TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PL13G. [I FOUNDATION 2ND [ ] INSULATION [ ]\FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: � d 01 ' � o r DATE ) _ 1 7 — ® 7 INSPECTOR � fjF$o(/lyOlO �' b y�OUMV,�� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ I FOUNDATION 1ST [ ] ROUGH PLBG. FOUNDATION 2ND [ ] INSULATION LA[ ] FRAMING / STRAPPING [ ] FINALCION Z [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INS ` [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PEREMARKS: O`er ' CQA-�t f � DATE ' l 1 NSPECTOR �. FIELD INSPECTION REPORT DATE I COMMENTS j 11 FOUND�ATION(1S ) ar- y - 6-1 ------------------------------------- �. FOUNDATION (2ND) t�ri 1 z o ROUGH FRAMING& — y PLUMBING -- n � . INSULATION PER N.Y. STATE ENERGY CODE Ae FINAL -b ADDITIONAL COMMENTS o � X c a l Q C IQ ro \ y TOWN OF SOUTHOLD �,`` BUILDING�r�ERMIT APPLICATION CHECKLIST � i .' BUILDING DEPARTMENT Do`u have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 y 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey www. northfork.net/Southold/ PERMIT NO. 7 3 z= Check Septic Form N.Y.S.D.E.C. Trustees Examined Ah ,20� Contact: Approved ,20 06 Mail to: Disapproved a/c Phone: Expiration J j ,20.0 Building Inspector y APPLICATION FOR BUILDING PERMIT Date 120 INSTRUCTIONS a. This application MUST be completelyfilled in by typewriter or in ink and submitted to the.Building Inspector with 4 sets of plans, accurate plot plan to scale.Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building IInspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building�permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been,enacted in the interim,the Building Inspector may authorize,in writing,,the extension of the permit for an addition six.months.Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations,for the construction of buildings, additions, or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws, ordinances,building code,housing code,and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name,if a corporation) �. 6V eT 114 X�f1/1789 (Mailing address of applicant) State whether applicant is owner,lessee,agent, architect; engineer, general contractor, electrician, plumber or builder Name of owner of premises ZM ey Z 41. (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: House Number Street Hamlet County Tax Map No. 1000 Section 87 Block a Lot 3 Subdivision Filed Map No. Lot (Name) _ / f ff ��f}� ^lA 1, 2. State existing use and occupancy oi,` emises and intended use and occupanc f proposed construction: a. Existing use and occupancy 111n6 s b. Intended use and occupancy �n�4QY lQesie�N�C 3. Nature of work(check which applicable): New Building X Addition Alteration Repair Removal Demolition Other Work (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. if dwelling, number of dwelling units Number of dwelling units on each floor / If garage, number of cars oZ 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front -� -Z`� Rear -+ aI4 Depth Height Ib' Number of Stories l Dimensions of same structure with alterations or additions: Front ft ar Depth Height Number of Stories 8. Dimensions of entire new construction: Front 55 Rear F S3' Depth Height 30 Number of Stories 9. Size of lot: Front + (166.S Rear. I 4 S Depth L� 10. Date of Purchase Lgg b Name of Former Owner 11. Zone or use district in which premises are situated t Del L 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES ✓ NO Will excess fill be removed from premises? YES NO_jt� 14.Names of Owner of premises S4M6 Address Phone No. 979 • qs`L Name of Architect M. LbaAo Address f'1-+'cw-La�+a7r �w P Phone No Q 7!3- a21Z�' Name of Contracto Address Phone No. 429 d? t n 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO ✓ * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES • NO * IF YES,D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey,to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. STATE-OF NEW YORK) -- SS: COUNTY OFt&LdRX f- LARRV Kci-LLer, being duly sworn, deposes,and says,that(s)he is the applicant (Name of individual signing contract) above named, XHe is the psew ��(Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn;joefore me this I day of A16,11"r 20 0 6 Notary P ignature bf Applicant JOHN C. AllO NOTARY PUBLIC-STATE OF NEW YORK QUALIFIED IN SUFFOLK COUNTY COMMISSION EXPIRES JULY 05,20 at pF SO(/T�,OI 0 Town Hall,53095 Main Road Fax(631)765-9502 P.O.Box 1179 G • Telephone(631)765-1802 Southold,New York 11971-0959 COUNT`I,� ' BUILDING DEPARTMENT TOWN OF SOUTHOLD July 27, 2007 Larry&Joan Kulick 21 Torlen Court Hauppauge, NY 11788 RE: 1895 Minnehaha Blvd, Southold TO WHOM IT MAY CONCERN: We are unable to complete your Certificate of Occupancy because of the following reasons: An application for Certificate of Occupancy is not one file. (Enclosed) v No Electrical Underwriters Certificate on file. The check is (not on file) $25.00 Final Health Department approval not on file. No final inspection has been completed. No Plumber Solder Certificate on file. (All permits involving plumbing issued after 4/1/84) Certificate of Compliance from the Trustees. Final Planning Board approval Final Fire Inspection from Fire Marshal. .BUILDING PERMIT: 32573-Z new dwelling SOUTHOLD TOWN BUILDING DEPT. Permit# Permit Date REScheck Software Version 3.7 Release 1 b Compliance Certificate Project Title: KULICK RESIDENCE `. Report Date:11/10/06 Energy Code: New York State Energy Conservation Construction Code Location: Suffolk County,New York Construction Type: Detached 1 or 2 Family Heating Type: Non-Electric Glazing Area Percentage: 20% Heating Degree Days: 5750 Construction Site: Owner/Agent: Designer/Contractor: 1895 MINNEHAHA BOULEVARD LARRY KULICK MICHAEL LOGAN SOUTHOLD,NY 11971 1895 MINNEHAHA BOULEVARD MTL SOUTHOLD,NY 11971 27 TORLEN COURT HAUPPAUGE,NY 11788 Co .. Cavity Cont. Glazing Assembly R-Value R-Value or D.. Ceiling 1:Flat Ceiling or Scissor Truss: 1743 39.9 0.0 51 Ceiling 2:Cathedral Ceiling(no attic): 481 31.8 0.0 15 Wall 1:Wood Frame,16"o.c.: 3042 24.8 0.0 129 Window 1:Vinyl Frame:Double Pane with Low-E: 227 0.340 77 Door 1:Glass: 376 0.340 128 Floor 1:All-Wood Joist/Truss:Over Unconditioned Space: 2224 20.7 0.0 98 Air Conditioner 1:Electric Central Air:13 SEER Boiler 1:Other(Except Gas-Fired Steam):80 AFUE Statement of Compliance:The proposed building represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application.The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code. T l_o" Builder/Designer Company Name Date ANS CY KULICK RESIDENCE Page 1 of 4 REScheck Software Version 3.7 Release 1 b Inspection Checklist Date: 11/10/06 Ceilings: ❑ Ceiling 1:Flat Ceiling or Scissor Truss,R-39.9 cavity insulation Comments: ❑ Ceiling 2:Cathedral Ceiling(no attic),R-31.8 cavity insulation Comments: Above-Grade Walls: ❑ Wall 1:Wood Frame,16"o.c.,R-24.8 cavity insulation Comments: Windows: ❑ Window 1:Vinyl Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door 1:Glass,U-factor:0.340 Comments: Floors: ❑ Floor 1:All-Wood Joist/Truss:Over Unconditioned Space, R-20.7 cavity insulation Comments: Heating and Cooling Equipment: ❑ Air Conditioner 1:Electric Central Air: 13 SEER or higher Make and Model Number: ❑ Boiler 1:Other(Except Gas-Fired Steam):80 AFUE or higher Make and Model Number: Air Leakage: ❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. ❑ Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials. If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: ❑ Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: ❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment must be identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. ❑ Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: ❑ Supply ducts in unconditioned attics or outside the building must be insulated to R-8. KULICK RESIDENCE Page 2 of 4 ❑ Return ducts in unconditioned attics or outside the building must be insulated to R-4. ❑ Supply ducts in unconditioned spaces must be insulated to R-8. ❑ Return ducts in unconditioned spaces(except basements)must be insulated to R- ❑ Return ducts in unconditioned spaces(except basements)must be insulated to R-2. .Insulation is not required on return ducts in basements. Duct Construction: ❑ All joints,seams,and connections must be securely fastened with welds,gaskets,mastics(adhesives), mastic-plus-embedded-fabric,or tapes.Tapes and mastics must be rated UL 181A or UL 181 B. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). ❑ The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ❑ Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: ❑ Separate electric meters are required for each dwelling unit. Fireplaces: ❑ Fireplaces must be installed with tight fitting non-combustible fireplace doors. ❑ Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: ❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: ❑ Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: ❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps require a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. KULICK RESIDENCE Page 3 of 4 Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Temperature(T) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range ff) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) KULICK RESIDENCE Page 4 of 4 ICHAEL T. LOGA D j. . . JUL, 1 2 201f:117 6w DEPT L�T_-�N QF'Sni iTNOi D Duly�;=20 Town of Southold Building Depamment• 53095 Route 25'' P'O, Box.:1179' Southold,,New York 11971, Re The Kuhck'Residence; 1895 IvlinnehahaBoulevard',Southold',"NY 11971 Dear:Pat I am:writing,this letfer•in order to,, cument seveiaLrevisions that were in on the above referenced project duringthe construction ofahe residence , The-first change involved using `a pr'e-manufactured fireplace-insert in lieu of a traditional masonry fireplace. rI have attached a'detail of the fireplace framing.for your records. The second',change involved the installation of a combination of Hand'Foamy closed-cell polyurethane foam and Guardian Fiberglass'Insulation. -create a state=of-theart insulation system; In lieul of the R19 fiberglass batt insulation originally specified; a combination:of an 1=1/2'inch layer.,of . sprayed onHandi Foam® (R-value-of 6=7 per inch).was applied in'side'the wall'cavity prior: ' to the installation of a Guardian kraft-faced:fb' lass batt(R13).' This system.provides a , total value,,of at,leasi R23,exceeding that:which:was specified. The final-change involved the construction of a wood framed stair and landing outside:;of Bathroom No. 2 'in place of : . -the poured concrete stair and.landing detailed in the,original plans.. Enclosed are the details of the framed stair and landing. If.y®u should,need any additional:information p1e'ase contact the 'Sincerely, ; Michael'T: Logan;RA: MICHAEL T: LOGAN, ARCHITECT -27 TORLEWCOURT, = HAUFPAUGE;`'• :NY.11788 (631) 979=2129. TRIPLE WALL INSULATED FACTORY-BUILT FIREPLACES SHALL BE FLUE PIPE INSTALLED AS PER LISTED AND LABELED AND INSTALLED IN MANUFACTURERS 5PECIFICATION5 ACCORDANCE WITH THE CONDITIONS OF THE L15TINO. FAGTORY-BUILT FIREPLACES SHALL BE TESTED IN ACCORDANCE WITH UL 12'7 F'RE-FAB FIRE PLACE AS SELECTED 2" MIN. AIRSPACE TO GOMBU5TI5LE FRAMING z 12"•MIN. 0 NON-COMBU5TIBLE MATERIAL N =FUAS4,4'HEARTH EARTH EXTENSIONS OF APPROVED 5REPLACE. FI FACTORY-BUILT. FIREPLACE5 SHALL BE INSTALLED GLA OLA5 E) FIE DOORS IN ACCORDANCE KITH THE LI5TIN&•OF THE FIREPLACE. THE HEARTH EXTEN51ON SHALL BE'READILY D15TINOUI5HABLE FROM THE SURROUNDING FLOOR AREA. 6 ' REPLACE DETAIL SCALE: 514" JUL 12 20r' BLD6 DEPT. Lm/N F Sr)l1THOLD - --- a y+•,. ��„H T. TERRY I I y� : , ;1a , ;� f ► ,rt II III. SJl1y5 f`la� P.O. f ►x 1171fiOWN CLERK' �I • ;� th ++t r Suwhnitl. Nc��• Turk � L I LEGI5FRAR OF VITA1.5T"AT151ICS �?�^ IGD O� Fox (S I(,) 765.1 R` nSAl1RIAOF OFFIGI:R Tcicphunc (S 1()) 7(,5, , RECORDS MANAGEMENT OFFICEIt �01 I FREEDOM OF INFORMATION OFFICER OFFICE OF THE TOWN CLERK TOWN OF SOUTHOLD THIS IS TO CERTIFY THAT THE FOLLOWING RESOLUTION WAS ADOPTED BY THE SOUTHOLD TOWN BOARD AT A REGULAR MEETING HELD ON AUGUST 24, 1993 : RESOLVED that the Town Board of the Town of Southold hereby. adopts two (2) new forms to be used under the Flood Damage Prevent. regulations. Of, the Code of the Town of Southold: "Floodplain Development Permit application" ( FDP(93) ] , and "'Certificate of Compliance for Develu- ment in Special Flood Hazard Area ((:(C(93)) . J I TOV`;4 OF SOUTHOLD Judith T . Terry Southold Town Clerk August 25, 1993 1 APPLICATION �+ r PAGE I of 4 — TOWN OF SOUTHOLD FLO0DPLAIN DEVELOPMENT PERMIT APPLICATION This form is to be filled out in duplicate. SECTION I GENERAL PROVISIONS (APPLICANT to read and sign): L. No work may start until a permit is issued. 2 The permit may be revoked if any false statcmcats are made hcrein- 3. If revoked, all work must cease until permit is rc-issued. 4. Development shall not be used or occupied until a Certificate of Compliance is issued. 5. The permit will expire if no work is commenced within six months of issuance. 6. Applicant is hereby informed that other permits may be required to fulfill local, state and federal regulatory requirements. 7. Applicant hereby gives consent to the Local Administrator or his/her representative to make reasonable inspections required to verify compliance. 8._ I,THE APPLICANT,CERTIFY THAT ALL STATEMENTS HEREIN AND IN ATTACHMENTS TO _ THIS APPLICATION ARE,TO THE BEST OF MY KNOWLEDGE,TRUE AND ACCURATE. (APPLICANTS SIGNATURE) ����'i-s�� DATE rZ jd JSECrION 2: PROPOSED DEVELOF.trIENT (Tp be completed by APPLICA En NAME ADDRESS TELEP HONE AP P LI CA]gT BUILDER tNG INEER PROJECT._I.00ATION: To avoid delay is proc=s ng the application, please provide enough information to easily idcatify the project locadon_ Provide the street address, lot number or legal description (attach) and, outside urban areas, the distance to the aearcst intusecting road or well-koown 1.16dmark A sketch attached to this application showing the project Iocadoo would be helpful. FDP(93) " APPLICATION Fu PAGE 2OF4 DESCRIPTION OF WORK (Check all applicable boxes): A STRUCTURAL DEVELOPMENT ACTIVITY STRUCTURE TYPE D New Structure ❑ Residential (1-4 Family) ❑ Addition O Residential (More than 4 Family) ❑ A (cration O NOD-residential (Floodproofmg? ❑ Yes) ❑ Relocation ❑ Combined Usc (Residential & Commercial) Cl Demdution' ' P O Manufactured (Mobile) Home (In Manu- ❑ Replacement factured Home Park?- ❑ Yes) ESTIMATED COST OF PROJECT S B. OTHER DEVELOPMENT ACTIVITIES. O Fill O Mining O Drilling O Grading ❑ Excavation (Except for Structural Development Checked Above) ❑ Watercourse Alteration (Including Dredging and Channel Modifications) , O Drainage Improvements (Including Culvert Work) ❑ Roadi, Street or Bridge Construction } SuF ' sion (New or Expansioo) / O I //dual Water or Sower Systcm O Othcr (Please Specify) After completing SECTION 2, APPLICANT should submit form to Local Administrator for review. SECTION 3• FLOODPLAIN DETERMINATION CFo be completed by LOCAL ADM IN"ISTRATOK) The proposcd dcvclopmcnt is located on F[R-M Panel No. . Dated The Proposed Development: ❑ Is UIQT located in a Special Flood Hazard Area (Notify the applicant that the application review is complete and NO FLOODPLA-N DEVELOPMENT PERMIT IS REQUIRED). ❑ Ls located in a Special Flood Hazard Arca. FTRM Tone designation R too-Year flood elevation at the site is:' ' Ft. NGVD (MSL) ❑ Uaavailablc O Tbc proposed dcvclopmcnt is loca(cd io a Iloodway, FBFM Panel No. Dated O Scc Sccuon d for idditional instructioos. SIGNED DATE is• t APPLICATION ry PAGE ] OF'4 SECTION 4 ADDITIONAL INFORMATION REQUIRED (To be completed by LOCAL.ADMINIST'RATQR1 The applicant must submit the documents checked below before the application can be processed: O A.SILC plaa showing the location of all existing structures, water bodies, adiaceot roads, lot dimensions and proposcd devclopmcnt. O Development plans,drawn to scale, and specifications, including where appUcable: details for anchoring structures, proposed elevation of lowest floor(including basement), types of water resistant materials used below the first floor, dctaiLs of floodproofwg of utilities located below the first floor and details of enclosures below the first floor. Also O Subdivision or other development plans (If the subdivision or other development axceeds 50 lots or 5 acres,whichever is the lesser, the applicant must provide 100-year flood elevations if they arc not otherwise available). O Plans showing the extent of watercourse relocation and/or landform alterations_ O Top of new Cdl elevation Ft. NGVD (MSL).. ❑ Floodproofing protection level (non-residential only) Ft.NGVD (MSL). For floodproofed structures,% ppGcaot must attach ccrtiftcation from r-gistered cngiineer or - architect. ❑ Certification from a'iepstercd cngi.necr that the proposed acLivit�y in a regulatory [IOodway will not result inany increase in the height of the 100-year flood. A copy of all data and calculations supporting. this finding must also be submitted. O Other. SECTION 5 PERMIT DETERMINATION fTo be completed by LOI;AL ADMIN[STRA.TORI I have determined that the proposcd activity'. A. O Is B. O Is not in conformance with provisions of Local Law if , 1-9_. The permit is issued subject to the conditions attached to and made part of this permit. SIGNED DATE if BOX A is chcckcd, the Local Administrator may issue a Dcvclopmcot Permit upon payment of designated (cc. If BOX B is chcckcd, the Local Administrator will provide a wrinco summary of deficiencies. Applicant may revise and resubmit an application to the Local Administrator or may request a bearing from the Board of Appeals. APPLICATION W PAGE 4 OF 4 APPEAJS: Appealed to Board of Appeals? O Yes O No Hearing date: Appeals --- Conditions SECTION 6• AS BUILT ELEVATIONS (To be submitted by APPLICANT before Certificate of Compliance is issued The following information must be provided for project structures. This section must be completed by a registered professional engineer or a licensed land surveyor (or attach a certification to this application). Complete I or 2 below. I. Actual (As-Built) Elevation of the.top of the lowest floor, including basement rn Coastal High Hazard - Areas bottom of lowest structural member of the, lowest floor, excluding piling and columns) is: FT. NGVD (MSL). L Actua-I (As-Built) Elevation of floodproofing protection is FT. NGVD (MSL). NOT' Any work performed prior to submittal/bf the above information is at the risk{6f the Applicant. SECTION 7• COMPLIANCE ACTION (To be completed by LOCAL ADMINISTRATOR) The LOCAL ADMINISTRATOR will complete this section as applicable based oo iaspectia❑ of the project to ensure compliance with the community's local law for flood damage, prevention. INSPtMONS: DATE BY DEFICIENCIES? O YES ❑ NO DATE BY DEFICIENCIES? O YES O NO DATE BY DEFICIENCIES? ❑ YES ONO SECTION 8' CERTIFICATE OF QOMPLIANCE(To be completed by LOCAL ADMINISTRATOR) _ Ccrtificatc of Compliance issued: DATE: BY: Xttactiment B SAMPAi E j CERTIFICATE PF COMPLIANCE for Development in a Special Flood Hazard Area TOWN OF SOUTHOLD CERTIFICATE OF COMPLIANCE FOR DEVELOPMENT IN A SPECIAL FLOOD HAZARD AREA (OMWER MUST RETAIN THIS CERTIFICATE) PREMISES LOCATED AT: PERMIT NO. PERMIT DATE OWNERS NAME AND ADDRESS: CHECK ONE: 0 NEW BUILDING 0 E7(ISTING BUILDING 0 VACANT ' LAND THE LOCAL ADMINISTRATOR IS TO COMPLETE A., OR B. BELOW: A. COMPLIANCE IS HEREBY CERTIFIED WITH THE REQUIREMENTS OF LOCAL LAW # , 19 SIGNED: DATED: B. COMPLIANCE IS HEREBY CERTIFIED WITH ` ll-F- REQUIREMENTS OF LOCAL LAW # , 19_, AS MODIFIED BY VARIANCE # , DATED SIGNED: DATED: C !C ( 93) GENERAL NOTES FOR WOOD-FRAMED STAIR AND LANDING LATTICE PANEL INSTALLATION OPTIONS 4 x 4 post r 3 p 4 x 4 post 1. PROVIDE TWO(2)8"DIAMETER SONOTUBE POURED CONCRETE FOOTINGS AT STAIR LANDING. FOOTING TO ;" x 1"cleat 2"buglehead finishing nail EXTEND BELOW GRADE A MINIMUM OF 36 INCHES. screwed to post screw ` 4 2. ALL STRUCTURAL FRAMING LUMBER TO BE"WOLMANIZED". R 4„quarter-round Lattice panel h Chamfered edge molding nailed to post 3. PROVIDE 2"X 6"LEDGER LAGGED INTO HOUSE FRAMING. - Lattice panel 4. PROVIDE 2"X 6"DECK JOIST @ 16'O.C.ATTATCHED USING 3"bugle ad screw METAL JOIST HANGERS. Lattice panel Lattice panel 5. ALL WOOD DECKING TO BE 5/4"x 6'MAHOGANY DECKING: ',-"-dia. drainage=noefl a"quarter-round 9Channel molding `b a molding 6. ALL CONSTRUCTION SHALL CONFORM TO THE NEW YORK drilled through b >• 4d finishing nail 2 x 3 rabbeted t� g STATE BUILDING CONSTRUCTION CODE. channel and bottom rail Bottom rail frame fastened 7. ALL WOOD RAILINGS SHALL BE CONSTRUCTED TO to post WITHSTAND A LATERAL IMPACT AT THE TOP OF 50 POUNDS PER SQUARE FOOT(LINEAR LOAD)AS PER THE NEW YORK STATE RESIDENTIAL CODE. I FRAMING DETAILS FOR STAIRWAY . r - ,} 2 x 2 baluster LEDGER CONNECTION TO WOOD-FRAMED WALL a 2 x 4 top rail >. - atenor sheathing Wall stud Sidings ✓ ! Flashing is tucked underneath siding and r' 4 tr. bent over top edge of ledger board. Decking board 2 x 34" �x� e«�r„Ptata h A z� ledger } ; ia4 srt wnos DOUBLE2"x6" j �j f Jia sar?' x K. xasc , GIRDER(FLUSI1) F } 2 x 4 bottom rail 4 x 4 newel post screwed 2 x 6 riser to stair stringer and to riser p�. . '� ws 2 x 6 tread 2 x 4 cleat anchored to concrete Sill Poured-concrete pad SMasg t Remove siding to expose sheathing pry f0un dat�bn .,. {.c• . for attaching ledger. v h �` Gt2DER ��JS N 11A 4.d 3. o / YA') u V x �E�1)4 1-'L Permit# Permit Date REScheck Software Version 3.7 Release 1 b Compliance Certificate Project Title: KULICK RESIDENCE Report Date:11110106 Energy Code: New York State Energy Conservation Construction Code Location: Suffolk County,New York Construction Type: Detached 1 or 2 Family Heating Type: Non-Electric Glazing Area Percentage: 20% Heating Degree Days: 5750 Construction Site: Owner/Agent: Designer/Contractor: 1895 MINNEHAHA BOULEVARD LARRY KULICK MICHAEL LOGAN SOUTHOLD,NY 11971 1895 MINNEHAHA BOULEVARD MTL SOUTHOLD,NY 11971 27 TORLEN COURT HAUPPAUGE,NY 11788 .. IBM Ceiling 1:Flat Ceiling or Scissor Truss: 1743 39.9 0.0 51 Ceiling 2:Cathedral Ceiling(no attic): 481 31.8 0.0 15 Wall 1:Wood Frame,16"o.c.: 3042 24.8 0.0 129 Window 1:Vinyl Frame:Double Pane with Low-E: 227 0.340 77 Door 1:Glass: 376 0.340 128 Floor 1:All-Wood Joist/Truss:Over Unconditioned Space: 2224 20.7 0.0 98 Air Conditioner 1:Electric Central Air:13 SEER Boiler 1:Other(Except Gas-Fired Steam):80 AFUE Statement of Compliance:The proposed building represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application.The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code. 14M. L. . LCAA-14 Mic;w*Ek_T LQC-,<d ,APQ#_ _Cr 11-21-Q6 Builder/Designer Company Name Date KULICK RESIDENCE Page 1 of 4 REScheck Software Version 3.7 Release 1 b Inspection Checklist Date: 11/10/06 Ceilings: ❑ Ceiling 1:Flat Ceiling or Scissor Truss,R-39.9 cavity insulation Comments: ❑ Ceiling 2:Cathedral Ceiling(no attic),R-31.8 cavity insulation Comments: Above-Grade Walls: ❑ Wall 1:Wood Frame,16"o.c.,R-24.8 cavity insulation Comments: Windows: [� Window 1:Vinyl Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door 1:Glass,U-factor:0.340 Comments: Floors: ❑ Floor 1:All-Wood JoistlTruss:Over Unconditioned Space,R-20.7 cavity insulation Comments: Heating and Cooling Equipment: ❑ Air Conditioner 1:Electric Central Air:13 SEER or higher Make and Model Number: ❑ Boiler 1:Other(Except Gas-Fired Steam):80 AFUE or higher Make and Model Number. Air Leakage: ❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. ❑ Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: ❑ Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: ❑ Materials and equipment,must be installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment must be identified so that compliance can be determined. ❑ Manufacturer manuals for all.installed heating and cooling equipment and service water heating equipment must be provided. ❑ Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: ❑ Supply ducts in unconditioned attics or outside the building must be insulated to R-8. KULICK RESIDENCE Page 2 of ❑ Return ducts in unconditioned attics or outside the building must be insulated to R-4. ❑ Supply ducts in unconditioned spaces must be insulated to R-8. ❑ Return ducts in unconditioned spaces(except basements)must be insulated to R- ❑ Return ducts in unconditioned spaces(except basements)must be insulated to R-2. Insulation is not required on return ducts in basements: Duct Construction: ❑ All joints,seams,and connections must be securely fastened with welds,gaskets,mastics(adhesives), mastic-plus-embedded-fabric,or tapes.Tapes and mastics-must be rated UL 181A or UL 181 B. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). ❑ The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ❑ Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: ❑ Separate electric meters are required for each dwelling unit. Fireplaces: ❑ Fireplaces must be installed with tight fitting non-combustible fireplace doors. ❑ Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: ❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: ❑ Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: ❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps require a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. KULICK RESIDENCE Page 3 of 4 Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Temperature("F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range("F) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Heating Systems Low Pressurelfemperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) KULICK RESIDENCE Page 4 of 4 N DWELLING PUBLIC WA TER c A loe. hlSE i 4 unKraw o ?O' STREEI' �E(,E 1�u° Q WABUN ASPHALT DIRT ROAD SURVEY OF PR009E ,,fjY ,i e!. DIRT ROAD N87.26'00"E 145.00, A T LA UGHINGOG WATER: 58 12.05' LIT RAIL FENCE c FE t.•L F• TOWN OF S�? FE o.r'w TOP s oN °:4"w el. 12.2 (MON 03'wGH, SUFFOLK CO UFNT _, NOTE MCF i:_ 1 1000-87-03-53 zz , a w 1 �, SCALE. 1'=30' a Abandonment of existing sanitary system must be in MARCH 13, 2006 _ 0 oa 1 ornfrermance with aepaL a requirement Submit APRIL lO, 2006 (test hotel Completed for.n WW-fu as proof. aL ;7 200����;r,o/)a.,0 (A UL. _7 �006 f� odd,(onsl a Zp�'E ,t �I ter. y I p 'v ` SUFFOLK COUNTY DEPARTMENT OF HEARTH SEt�VICM !L C r v D 1 tt1 I, PERMIT FOR APPROVAL OF CONSTRUCTIOU RZA', II] D D 1 m 1 Y_, 1 1 a SI OGLE FAIMLY REsiDz,%cE ONLY t- m DATE 1 V .�s��. . REF. No.APPR y �E f1s / r FOR MAXI i1 OF QEi?!?001 D ��E IJ Trl �;l l,, r i� ;, 1 o a f' N m ooD D D Z EXPIRES THR E YEARS FR M DATE Of ROYAL Io 9, bed rev x Z HSE. CI P' I.P . ; x1 = FIN. FLR. 13 r N ® 191 EL.10 PROPOSED GRADE EL. B _ -, x — 1'p 1.Q y /—e[/Sf. �6'E (n I.E.,Z7.2 I � 3'SAhp 1 ` 1 2' 861s, $ PI A LE. e.9 S1250 EPTIC Gal.. -E 6. I.E. 62 8 .P. 2 COLLAR TEST HOLE b eL° ti0� TANK 3/7/06 o% ZoN-L A Ce! e0 Z N cRO1RdQWA7ER EL.1.6 r MI". I— DARK BROWN SANDY LOAM OL y UD PROPOSED SEWAGE DISPOSAL SYSTEM 6 POOLS — — 15' /4" \ d�IV - D WITH CLEAN SAND 3' COLLAR-IR50 GA'L. PRECAST ; / �y> o;ooR Pr�� CONCRETE SEPTIC TANK-BOTTOM OF 4EACHING POOLS TO BE 2' ABOVE GROUND WATER BROWN scrY salvo _SW 63T„ 0 \MF . /,' SEPTIC SYSTEM CROSS SECTION —— 5' BROWN CLAYEY SAM SC \\^ ,r \ — 6.4'WATER N BROWN CLAYEY SAND SC )i r c 0f/{y C i�T � fp — — 7. f. F of n WATER � ASpy'9(T EL.J.6" N BROWN sanD sP `t .Q EXCAvATION INSPECTION REQUIRED. ass 64. one 13' ,o AFL</N R SANITARy SYSTCM �( F NE' BYMcDONALD GEOSCIENCE. �B4/c G BY 'EA��°t.� D PART���T 5� MEN AREA=26,253 SO. FT. `�� 6`''r'S�Qa * N.. v r N . 678 -F- ANY ALTERA170N OR AD017ION TO THIS SURVEY IS A VIOLATION F a �s �o�j� �lf���I� or rgMoYeol- PECONIC UR �Y OF SECTION 72090F THE NEW YORK STATE EDUCARON LAW. (631) 765-50 N� g� 1797 EXCEPT AS PER SECTION 7209-SUBDIVISION 2. ALL CERTIFICAT70NS ®= Prop. E;t v�c;l on s NS HEREON ARE VALID FOR THIS MAP AND COPIES THEREOF ONLY IF �Hw.y ELEVATIONS ARE REFERENCED TO NGVD. P.O. BOX 909 Fp SAID MAP OR COPIES BEAR THE IMPRESSED SEAL OF 174E SURVEYOR 1 12JO TRA VELER ST WHOSE6-130 SIGNATURE APPEARS HEREON. ■=MONUMENT F[aoo ZdN�S //LdM F/2M 3&103 c o/� G SOUTHOLD, N. Y. 11971 N DWELLING `p I HSE PUBLIC WA TER 4 '1` ` ASPHALT h, DIRT ROAD'S 1 SURVEY OF PROPERTY eL 12.05'\ WABUN RT ROAD i AT LAUGHING WATER = - -- ----- - - --- - N8T26'00"E cIT RAIL. ,'FE c,c:F Ir r� r ►2� f1 ;- O.f'W- + rap.9w, TOWN OF SO UTHOLD. 0.6N ,� 90 4a SUFFOLK COUNTY, N. Y. = + 1D00-87 03-53 DEC 82oo6 ^ 'Z 0'0'1 SCALE: 1'=30' o o MARCH 13, 2006 TC�' � ; to��Y e► ro.� APRIL l0, 2006 (lest hole) - Z /7 2001o�QQ.o�itio�a.� \ w� Cr► JUL 7, f1006 (6 di7lons) ma 1 _ f !0 _ . opt, /�, G�/-svweo^' tiae) n / O Dec 2"cep ovrs� m� 1 �'p►�� � t1sla''b- s1 p 2(0,26t7G < f 'el 1�q Dec. 27, 2oo�lf. 6/r> C % .,� Z �' D Gin y _ i _ \ 'U la v >Lo N f I,� ( 1 Z m 6 S� U � �11:!?, ��. 1m = � HSE. l4.8 D FIN. FLR.,EL/4,B EL.ro PROPOSED GRADE ELI s via FE 2. lE 72 '— , 8 SAND M B6 $ 8 ' LE 69 .E 6. COLLAR N D MON ------r ® '. % .�xie/r�5- _ A ', 1250 GOL�: =l:E. 6z L.P. 2: TEST HOLE b y ,p3/ ___ F SEPTIC I - eL 7.5• TANK 2.MUV 317106 0 ZoN A I sa. z ro GRDLJMp wain EL 1.6 I D ' DARK BROWN SANDY LOAM OL v PROPOSED SEWAGE DISPOSAL SYSTEM 6 POOLS — — 1.5' ,;nvry Gt/IV a 's WITH CLEAN t;4ND.3' COLLAR-1250 GAt. PRECAST Kq o1P -� CONCRETE SEPTIC TANK-BOTTOM OF LEACHING BROWN SALTY SAND SM %63� \ �' `ME Pr i POOLS TO BE 2' ABOVE GROUND WATER. l 5' BROWN CLAYEY sAnv sc 100- SEPTIC SYSTEM CROSS SECTION —— ��^ — — 6.4'71 WATER N BROWN CLAYEY SAND SC ,� _ Ep'G� \COH WATER N BROWN FPC SAM7 SP [ / � _ — EL. 5& - o •8p�1� s s�� � �n`'ry - 13' pF NE►Vv BYMCDONALD GEOSCIENCE. �BL/C G 5 Cr �� Fv9Ed �T F , AREA-26 253 80. FT. �'� 6`''�-s `� '� y" ` �'�•f- �4ac `I N. I S -LIC. NO. 49618 ANY ALTERA77ON OR ADDI77ON TO THIS SURVEY IS A VIOLATION / Fxi�-elo CrPs 46 fdled•,O or /'emvveoL. OF SECTION 72090E THE NEW YORK STATE EDUCATION LAW. � j, c P � C � .C. EXCEPT AS PER SEC77ON 7209-SUBDIVISION 2. ALL CER77F7CAT7ONS 8 - Prop- �/ovczt,ons (63 (631) 765-1797 HEREON ARE VALID FOR THIS MAP AND COPIES THEREOF ONLY IF P.O. SAID MAP OR COPIES BEAR THE IMPRESSED SEAL OF THE-SURVEYOR A ELEVATIONS ARE REFERENCED TO NGVD. 1230 TR � TREET wHosE SIGNATURE APPEARS HEREON. ■=MONUMENT "aD ZONES &QM 34,103 c ole e- G SOUTHOLO, N. Y. 11971 06-130 i % c. N ��- L-' WABUNT ROAD ASPHALT DIRT ROAD STREET SURVEY OF PROPERTY DIR _ Ns�•2s'oo�E ' •00� 1�-- AT LAUGHING WATER SPLIT RAIL FE C.L F FE 0.f'W TOWN OF SO UTHOLD 1.4 W SUFFOLK COUNTY, N. Y. r 1000-87-03-53 1 SCALE. 1'=30' 0 o CONCR nprJ MARCH 13, 2006 O O ` FpUN N EL. 13.7' 1 APRIL 10, 2006 (TEST HOLE) Z TOP FNOTM 220 p MAY 17, 2006 (ADD177ONAL) JUL Y 7, 2006 (ADDITIONS) O p y N OCTOBER 18, 2006 (REVISED HOUSE) rmrin o po DECEMBER 26, 2006 (2' CONTOURS) O�' o s DECEMBER 27, 2006 (FIN. FLR.) r 1 m FEBRUARY 8, 2007 (FOUNDATION LOCATION) C 22.0' 1 � � o CI 47.5 W a G7 5.5 CCN� xl Ln D D �'1 FOUNDATION 3.T 5.5 20.1' I m -a U) q OP FNOTN' x' D U) 5, T FEB 1 2 2� v 70.5'' v D N 1 42.0FE ' 1 �•i ' — 0 P � CONCRETE COLUMNS 1 2.6'E (n _ -- ------ -- b ev P ry \ * H>Ob jo E� 0- p ' NE W),o CD AREA-26,253 SO. FT. 961 t�4N 8 ANY ALTERA770N OR ADD177ON TO THIS SURVEY IS A WOLA77ON ECONIC SU EYORS, P. OF SECTION 72090E THE NEW PORK STATE EDUCATION LAW. . G. 631 765-5020 FAX 631 765-1797 EXCEPT AS PER SEC77ON 7209-SUBDIVISION 2. ALL CER77FICA77ONS HEREON ARE VALID FOR THIS MAP AND COPIES THEREOF ONLY IF P.O. BOX 909 SAID MAP OR COPIES BEAR THE IMPRESSED SEAL OF 7HE SURVEYOR 1230 TRAVELER STREET WHOSE SIGNATURE APPEARS HEREON. ■=MONUMENT SDUTHOLD, N. Y. 11971 —130 N SCDHS Ref. # Rl 0 - 06 - 0053 WABUN ASPHALT DIRT ROAD STREET' SURVEY OF PROPERTY DIRT ROAD FE N87'26'00"E '45•00' 1.0 AT LAUGHING WATER SPLIT RAIL �E FF C. F. � 0.1'W TOWN OF SO UTHOLD 0. f 6N 1.4'W SUFFOLK COUNTY, N. Y. 1 � ? N -41 gyED 1000-87-03-53 SCALE. 1'=30' MARCH 13, 2006 O W` 3.1 Ua APRIL 10, 2006 (TEST HOLE) MAY 17, 2006 (ADDITIONAL) .p JUL Y 7, 2006 (ADDITIONS) . O p W 1 1 OCTOBER 18, 2006 (REVISED HOUSE) m� R o DECEMBER 26, 2006 (2' CONTOURS) GA • r p 1 1 DECEMBER 27, 2006 (FIN. FLR.) FEBRUARY 8, 2007 (FOUNDATION LOCATION) C XI JUNE 12,-2007 (FINAL) ' M > x DCI 47.9' 1 X O Z. s' Z STORY X; n O FRAME HOUSE D m1 • CA 1 2a' S'6' 1 v 70.5` - o 'per " y SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES I~ IV { �?6 42.3' 1 lk ,AQI3 VAL OF CONSTRUCTED WORKS FOR l.p !.P 3W "` FE Z. 2 J@rLE FAMILY RESID NCE JUL 1 LL 12.6E / a6�S• 1 P S010Ps ?ate H.S.Ref.iVo. �� b She sere�posal and water supply facilities at this location have been A o,¢, � N inspt� or c d arbertified by this Departm t or other agencies and found to \ °ssy P'4� �P� be savory FOR A MAXIMUM F 7: BEDROOMS. _? �, o k� \ e Walter J.Hilbert, ., 11 � Office of Wastewater Management' FpcF 0.4C- ,9Sphq(T NEVy CO AREA=26,253 80. FT. 18 ANY AL 1FRA 110N OR ADDITION TO THIS SURVEY IS A VIOLATION IS(63 65-1797 CONI OF SECTION 72090F THE NEW YORK STATE EDUCATION LAW. (� EXCEPT AS PER SECTION 7209—SUBDIVISION 2. ALL CERTIF7CA77ONS 1) 765— HEREON ARE VALID FOR THIS MAP AND COPIES THEREOF ONLY IF P.O. BOX 909 SAID MAP OR COPIES BEAR THE IMPRESSED SEAL OF THE SURVEYOR 1230 TRAVELER STREET 0CJ�_1 cJ 0 WHOSE SIGNATURE APPEARS HEREON. ■=MONUMENT SOUTHOLD, N. Y. 11971 c RES E:NC, s_ z z ' �~ -"---- DIRT RIIAD 1895 1AHA BLVD . , SOUTI'"' OLD .... Y O p (' SPLIT RAIL 1 145.Oo" =ENGE mp ) o0 o� rn STU 1/2 BEARING PLATE Z I ' °• .�.- Beam and Strap ---` 22.0' 00 -� 2 3/8" end distance 1-�fi1 ® �- N/O/F 20.0' I ' °• o' LAURIE ' SIDE YARD I' o . RAFKIN GARAGE CJELLAR o CLASS ENTRY HEADER e0. • d ..a. °• W � W} O ' 1 QQ O ' p <. e 1 �' 1 5.5' 16.0' O 3 p 16.5' ' �� SARA L, e 2(1 I t70.0 - - 20.0' V 0. JP G HAWKIN5 rn �(! Y tL- � . rn N I rn WOOD FRAME 142 0" 4 O LTP4 20 GA. 3"x 4 1/4" Simpson Strong-Tie > I ' RE5IDENCE� Lateral Tie Plates g I 5.5' USE 1 2-8d x 1 112" NAILS LS A 24 I � (G-Nail5 into plate, G-Nail5 into box) 5.5' i I (PLACE @ 32" OC.) \\ cpv ( , 1/2" ROD REQUIRED DETAIL 2 r Simpson Strong-Tie DETA I I i \ ✓o - r FOR STU 1/2 C5 Coiled Strap and 86 G 42,0 55 1 50ALE: 5/4" = I'-O" I LTP4 Lateral Tie Plate I �S \ PORCH Dbl.511 Plate / Floor / Stud Connection Detail \G�. �_ 5TEP5 STEPS 11 THREADED ROD HD5A HOLDDOWN C520 Strap LTP•4 Lateral Tie Plate NORTH 47.5 (PLACE @ I G" CC.) CNN COUPLER NUT N 4 20 GA. 24" L 0 n RIO-O 15.01 MI 1. ' >000 USE 9-1 Od NAILS @ STUD �; i SIDE Y MINIMUM END U5E 9-1 Od NAILS @ BOX * PLATE O� `\ DISTANCE iK ODOWN INSTALLATION ION DETAIL ° MINIMUM EDGE ° DISTANCE • T Ii ? CORNER STUD �j I CONNECTED TO TRANSFER SHEAR o ` b' � MACHINE 80LT5 °\� i PLUMf?F-R CFRT•Jrl(;/-'T ' • WITH BP WASHER ON LEAS% i o \� i CERTIFICATE Gr © 14--o-SOLDER USE FJ IN WATER �{ S UPPL Y SYSTf M CANNOT EXCEED 2110 OF 1% LEAD. ANCHOR BOLTS ® � � 'RTIFt TION F'" ALL CONSTRUCTION SHALL NAIL , G NyEC -I I m ,UEE�'THE REQUIREF.7 TS OF THE U11 'kn PLUMBING COD'S OF NE',"' >TATE. ?ob• ALL PLUMBING WASTE DETAIL.. I i DST A I ( " - f-oil I ; 4 I/z" 0o r 4+ !` 8 WATER LINES NEED f� SCALE I - 1 -O T I ;<- a TESTING BEFORE COVERING SCALE: 5/ = i ii I m o ^ I10TED 4" I -C,� m ,l� !` .Ut�IN HD5A CORNER " DATE: 2 1/2" BY: L.�- is HOLDDOWN � �� l FEE: �� ;r ,����rNT AT '; , Stud to Bottom Plate � � a, � � T;FY BUILDING DE` � y •, 51 TE FLA KV�'21 i AIM TO THE Simpson Strong-Tie _ _ Simpson 5tron -Tie ' ii - i iLL. l".' 1NSPECT1i RSP4 G" L. SCALE: 1 20 - _ REQUIRED i• . :` "` r p - ti;RETE Fr: MT5 30 g ,,., •.,. .� � t�' ..�- r.;� ��oURF� �,. FOR RE5IDENTIAL GON5T?UGTION DE-�-A I � i.. �� �" 2. ROUGH - F:;Ar,4i��G & PLUME :,._ TOWN OF 50UTHOLD w9' . �� ,^�'" 3. INSULATION �` / 2ND 5UBM155/ON R505E TABLE R5o1.2(1) CLIMATIC AND GEOGRAPHIC DE515N CRITERIA T I DETAIL 4. FINAL - CONSTRUCTION M BREEZEwAr BX /0 /2�12/06 j ALL CONSTRUCTION SHA' L V .T T" ryEylgpN DATE WIND SUBJECT TO DAMAGE FROM IGE SHIELD ZON I NC DATA REQUIREMENTS OF THE 'v Ti ` N� vv GROUND .SEISMIC WINTER 5NOW SPEED DESIGN FROST LINE DESIGN UNDER- PUE61UN OR ORK STATE. NOT R �I DECAY LAYMENT FLOOD � LOAD (MPH) CATEGORY WEATHERING DEPTH TERMITE TEMP. REQUIRED HAZARDS I ZONED: [NON-CONFORMING) 27 TORLEN COURT,HAUPPAUGE,NY 11788 SEVERE 5' M-H 5-M II YES AE8 SCHEDULE OF FASTENERS DISTRICT: 1000 6:31 9'79-2129 45 FSF 120 G MECHANICAL FASTENERS BY "5IMP5ON STRONCr CIE GO." LOT AREA: 26,255 S.F. SECTION: 51 ARCHITECT SEE CODE SECTION FOR FOOTNOTES. 51MFWN 5TRON5 LOCATION TIE co. MANUF. # FASTENERS BLOCK: 05 PLANNER TYPICAL ROOF WN5TRUCTION "R" "U" TYPICAL WALL CONSTRUCTION "R" "U" TYPICAL FLOOR CONSTRUCTION "R" "U" ROOF RAFTER TO L5TA 24 ROOF RAFTER TO Wo3 zmy, 55 OT• INTERIOR AIR FILM 61 ROOF RAFTER 1 1/4" x 24" ROOF RAFTER COMPLY!" ----`�� PRKXELT EXTERIOR AIR FILM .17 EXTERIOR AIR FILM •17 IS IOd - ASPHALT ROOF SHINGLES(MINIMUM) .bb VINYL SIDING w/I/2" TUFF "R" BD. 4.0 Td6 RED OAK FLOORING(STAIN)(OR QUARRY TILE) .4'i �{APTF�, K.ULICK RESIDENCE 3/4" PLYWOOD SUBFLOOR T t 6 .41 FLOOD ON 1895 MINNEHAHA BOULEVARD #15 WILDING FELT * .12 TYVEK BUILDING WRAP .12 STUD TO PLATE TO MT5 50 G TO ROOF RAFTER TO STUD TO PLATE Sow;,`• . 1/2"COX PLYWOOD SHEATHING •4'I I/2 COX PLYWOOD SHEATHING .41 II 'i/8" B FLOOR JOISTS® Ib"o.G. ROOF RAFTER @ 16 O.G. '7- 10d x 1 1/2 7 - IOd x 1 1/2 N/R FRONT YARD: 40,0 0 BOTH 1 TJI"ROOF RAFTERS® Ib" O.G. 2" x b"STUD® I6" O.G.w/Rlq GATT I1.00 w/Rlq GATT INSULATION 19.00 " " " ' T OLD, NY 11971 EXTERIOR AIR FILM J1 @ MINNEHAHA BLVD./WABUN ST. U"IDERWRITERSCERTIF1C6 Ti'R.E DO NOT PROCEED WITH R-30G BATT INSUL. ® CATHEDRAL CEILING 30.00 INSULATION SILL TO JOIST TO CS 16 TO STUDS I/2 GYPSUM BOARD(TAPE,SPACKLE, .45 I/2" GYPSUM BOARD(TAPE,SPACKLE, 45 RQUlRED SITE PLAN FRAMING UNTIL SURVEY "I PAINT) PAINT) PLATE TO STUD 16 o.G. 20 - Sd 51DE YARDS: 150 MIN./55.0' AGGREGATE OF FOUNDATION LOCATIO TOTAL ROOF 31.S1 .031 INTERIOR AIR FILM bl TOTAL FLOOR 2012 .045 SILL PLATE TO 5/5" ANCHOR BOLTS @D 6-0" O.G., 1'-0" ® CORNER H/ 5/,5" B N A, OLTS HAS BEE 'rrivVED. TOTALWAL.L 24482 .04 FOUNDATION H/ 5" x 5" WASHER LBFP 5/e, PROVIDED SIDE YAR05: 20-0 / ±10 pRAyy�,p��p• PROVIDE neRAGE" ICE 4 WATER SHIELD -P' '\ 06:Qq• STUD TO RSP4 TO STUDS TO PLATES 1 ��• AT ALL VALLEYS,RID&E5,EAVES,RAKES, BOTTOM PLATE © 16, O.G. 4- 5d x 1 1/2" 4 - Sd x 1 1/2" , WALL. FLA5HIN6,ETC. BUILDING COVERAGE: ; ` 5151 F. / 26,255 S.F. = 14.49 DATE 11121106 DRANIN05 ,SPECIFICATIONS AND OTHER DOCUMENTS PREPARED BY THE ARCHITECT ARE THE IN5TRUMENT5 OF THE ARCHITECT'S SERVICE AND SHALL REMAIN THE t A PROPERTY OF THE ARCHITECT,V^IHETHER OR NOT THE PROJECT FOR WHICH THEY ARE INTENDED T/n�,f 15 CONSTRUCTED OR NOT. THE ARCHITECT'S DRAWINGS, 5PECIFICATION5 AND � PP14 TRs. -c-r OTHER DOCUMENTS HILL NOT BE USED ON ANY OTHER PROJECT5 FOR ADDITION5 TO v . } THIS PROJECT AND/OR FOR COMPLETION OF THIS PROJECT BY OTHERS, EXCEPT BY :CT AGREEMENT IN WRITING AND HITH APPROPRIATE 6OMPENSATION TO THE ARCHITECT. © GOPYRI C HT 2006 DFAAWN BY H. Mr4R�wN C I GENERAL GON5TRUGT I ON NOTE5 NAILING 5CHEDULE (CONTINUED) R3012.1 WIND DESIGN CRITERIA: THE STRUCTURE HAS BEEN DE516NED TO RESIST HORIZONTAL R406.3.4 BAGKFILL: REMAINDER OF EXCAVATED AREA ABOVE POROUS FILL SHALL BE TABLE 3•I R'f03.q.1 WEATHER-RESISTIVE BARRIER: ALL EIFS SHALL HAVE AWEATHER-IZE515TIVE BARRIER i, APPLIED BETWEEN THE UNDERLYING WATER-5EN51TIVE BUILDING COMPONENTS AND THE EXTERIOR PROVIDE SOLID SURFACES AT LEAST I I/4" WIDE, IN BOTH DIRECTIONS,AT ALL CORNERS FOR ; LOADS A550GIATED WITH 120 MPH WIND LOADS FOR EXPOSURE B IN ACCORDANCE WITH BACKFILLED WITH SAME TYPE 501L REMOVED DURING EXCAVATION. BAGKFILL NOT TO BE PLACED 1=LOOF2 5Hr=ATHIN6 INSULATION AND A MEANS OF DRAINING WATER TO THE EXTERIOR OF THE VENEER. A SECURING SUBFLOORING,DRYWALL, ETC. FOR SURFACES WITH FRAMING MEMBERS,OR WITH 2" WFCM - WOOD FRAME CONSTRUCTION MANUAL 14115 HIGH WIND EDITION. WIND LOADS ARE AGAINST WALL UNTIL WALL HAS SUFFICIENT STRENGTH AND HAS BEEN ANCHORED TO THE FLOOR STRUCTURAL PANELS WOOD BLOCKING SECURED WITH AT LEAST (2) 8D NAILS AT EACH END. WEATHER-RESISTIVE BARRIER SHALL BE COMPLIANT WITH ASTM D 226 TYPE I ASPHALT SATURATED RESISTED BY EXTERIOR PLYWOOD SHEATHING AND INTERIOR WOOD STUD WALLS WITH 6YP5UM ABOVE PER CODE SECTION R404.1.71. I" OR LESS ad 6" EDGE / 12" FILED FELT OR EQUIVALENT SHALL BE APPLIED HORIZONTALLY WITH THE UPPER LAYER LAPPED OVER THE BOARD. GREATER THAN I" IOd b" EDGE/b" FILED LOWER LAYER NOT LE55 THAN 2 INCHES (51 MM) AND SHALL HAVE ALL VERTICAL JOINTS LAPPED ALL PARTITIONS, EXTERIOR WALLS AND CEILINGS WILL BE COVERED WITH I/2" THICK GYPSUM WALL 406.1 CRAWL SPACE VENTS: PROVIDE I S.F. PER 150 5.F. OF FLOOR AREA. INSTALL VENTS WITHIN NOT LE55 THAN 6 INCHES (152 MM). BOARD, 5/, THICK FIRE CODE 6YP5UM WALL BOARD WALL5 AND GEILIN65 IN GARAGE AND 1/2 TABLE R3012(2) DOOR AND WINDOW REQUIRED 17�E51GN VALUES: 3 FEET OF EACH CORNER OF FOUNDATION. CRAWL SPACE ACCESS PANEL TO BE MIN. 18"x24" DIAGONAL BOARD 5HEATHING THICK M015TURE RESISTANT GYPSUM WALLBOARD USED AT BATHROOMS WALLS AND SURROUNDS, UNLESS MECHANICAL EQUIPMENT LOCATED PROVIDE A 22N50" ACCESS OPENING PER 5EGT: R-103A.2 FLA5HIN6,GENERAL: FLA5HIN6 OF EIFS SHALL BE PROVIDED IN ACCORDANCE WITH THE ALL EXTERIOR WINDOWS AND DOORS SHALL MEET MINIMUM WIND PRESSURES IN POUNDS PER I" x 6" OR I" x 8" 2 - ad PER SUPPORT ALL WOOD FRAMING, INGLUDIN6 JOISTS,BEAMS, POSTS STUDS, ETC., TO BE HEM FIR NO. 2 OR SQUARE FOOT(P.S.FJ FOR 3C)'-O" MEAN ROOF HEIIGHT,EXPOSURE B ZONE 5 A5 FOLLOWS: MI305.1.4. I" x 10" OR WIDER i 3 - ad PER SUPPORT REQUIREMENTS OF SECTION R103.5. BETTER R502.4 FLOOR PLUMBING CHASE BLOCKING TO BE FULL DEPTH, I. NAILING REQUIREMENTS ARE BASED ON WALL 15HEATHING NAILED 6" ON-CENTER AT THE PANEL EDGE. IF WINDOW / DOOR 50. FT'. AREA CATEGORY 110 MPH WIND CATEGORY 120 MPH WIND WALL SHEATHING 15 NAILED 3" ON-CENTER AT THE PANEL EDGE TO OBTAIN HIGHER SHEAR RI004 FACTORY BUILT FIREPLACES: TESTED IN ACCORDANCE WITH ULI2l AND INSTALLED PER FB = 1200 P51, 51NCULAR R502.6 BEARING ENDS OF JOIST, BEAMS OR 6IRDER5 SHALL HAVE MIN. 1 1/2" OF BEARING ON CAPACITIES, NAILING REQUIREMENTS FOR STRUCTURAL MEMBERS SHALL BE DOUBLED, OR MANUFACTURERS SPECIFICATIONS. EXTERIOR AIR INTAKE FROM EXTERIOR OF DWELLING OR FROM FB = 1400 P51, REPETITIVE 10 S.F. 2q.1 P.S.F. 347 F.S.F. WOOD AND METAL AND 3" MIN. ON MA50NRY OR CONCRETE. JOIST FRAMING FROM OFF051TE SIDES ALTERNATE CONNECTORS,SUCH A5 SHEAR IPLATE5, SHALL BE USED TO MAINTAIN THE: LOAD PATH. SPACES WITHIN THE DWELLING VENTILATED WITH OUTSIDE AIR SUCH A5 CRAWL OR ATTIC SPACES. 20 S.F. 2T2 F.S.F. 32.4 PS.F. OVER A BEARING SUPPORT LAP A MIN. OF 3" WITH MIN. 3-10d FACE NAILS, LEDGER 5TRIP5 NOT GARAGE AND BASEMENT EXCLUDED FROM OUTSIDE AIR SOURCE. CHASES SHALL BE FIRESTOPPED ALL PLYWOOD USED STRUCTURALLY SHALL MEET THE PERFORMANCE STANDARDS AND ALL OTHER 2. WHEN WALL 5HEATHIN6 15 CONTINUOUS OVER CONNECTED MEMBERS, THE TABULATED NUMBER AT EACH FLOOR AND GEILIN6 AND INSULATED THOROUGHLY ON INSIDE AND OUTSIDE WALL5 TO 50 S.F. 24b P.S.F. 2q3 PS.F. LE55 THAN 2"x2". OF NAILS SHALL BE PERMITTED TO BE RtEDUGED TO I - 16d NAIL PER FOOT. REDUCE AIR INFILTRATION. REQUIREMENTS OF APPLICABLE U.S. GOMME'RGIAL STANDARDS FOR THE TYPE AND SPECIES OF 100 S.F. 22.6 P.S.F. 26.q P.S.F. PLYWOOD AND BE 50 IDENTIFIED BY AN APPROVED AGENCY. (3/4" MIN.). ' 502:i.1 J015T BRIDGING: JOISTS EXCEEDING 2"xl2" ARE REQUIRED TO BE SUPPORTED M1305.1 FURNACES IN CLOSETS TO HAVE MIN. 30 CLEARANCE IN FRONT OF UNIT FOR SERVICE. THE ENTIRE WORK SHALL BE ACCURATELY FRAMED, PLUMB,LEVEL AND TRUE,WELL SPIKED, j LATERALLY AT MID SPAN BY SOLID BLOCKING OR DIAGONAL BRIDGING(WOOD OR METAL) AT ROOF 5HEATHING ATTACHMENT" REOUIRMENT5 FOR WIND LOA05 CLOSET WIDTH TO BE MIN 12" WIDER THAN FURNACE AND 3" MIN. CLEARANCE AT BACK AND SIDES. BRACED AND ANCHORED TOGETHER TO FORM A RIGID STRUCTURE AN TO INSURE EVEN SETTLEMENT R30122 SEISMIC EXCEPTIONS: ONE 4TWO FAMIL'.Y DWELLINGS LOCATED IN SEISMIC CATEGORIES B INTERVALS NOT EXCEEDING 8'-O". ENGINEERED JOIST BRIDGING GIT PER MANUFAJRER'S TABLE 3B PROVIDE AGGE55.PANEL OPENING LARGE ENOUGH TO REMOVE LARGEST APPLIANCE BUT NOT LE55 AND SHRINKING THROUGHOUT. UNLESS OTHERWISE NOTED ON THE PLAN ALL FRAMING MEMBERS TO ' 4 G AND TOWNHOUSES LOCATED IN 5E15MIC CATEGORY B ARE EXEMPT FROM SEISMIC INSTALLATION REQUIREMENTS. THAN 22"x30". FOR APPLIANCES LOCATED IN ATTIC, INSTALL SWITCH OPERATED LIGHTING FIXTURE REQUIREMENTS. FOUNDATIONS TO BEAR ON SOIL OF 51TE GLASS D OR BETTER FOR DWELLINGS TO I10 MILE WINID SPEED (mph) AND RECEPTACLE. PROVIDE CLEARANCES PER MANUFACTURERS INSTALLATION INSTRUCTIONS. BE I6" O.G. BE SEISMIC CATEGORY C. 502.b DRILLING 4 NOTCHING DIMEN51ONAL LUMBER: TO CONFORM TO SECTION R502.8.1 AND 51IRUGTUIZAL e.>HEATMIN6 ' FICORES R502h SECTIONS R802.1.1 FOR JOIST ,RAFTERS AND BEAMS, R602.6 FOR STUDS/R6O2.61 DOUBLE J015T5 AROUND ALL OPENIN65 4 BELOW ALL PARALLEL WALL PARTITIONS, R 30122.4 MAXIMUM DEAD LOADS: FOR WALL PLATES, R602"i FOR HEADERS AND FIGURE R602.6(U AND (20. FOLLOW E F MI3CT1.3 APPLIANCES WITH IGNITION SOURCE SHARING GARAGE FLOOR TO BE ELEVATED IS" MIN. ROOF/GEILIN6 15 P.5.F. EXTERIOR ;WALL 15 P.S.F. MANUFACTURER'5 SPECIFICATIONS FOR ENGINEERED WOOD PRODUCTS. 5HEATHIN6 LOCATION RAFTER/TRU55!SPACING MAXIMUM NAIL SPACING FOR AND PROTECTED FROM IMPACT BY VEHICLE. ALL STRUCTURAL WOOD SHALL BE KEPT 2" BACK FROM CHIMNEYS. FLOOR 10 P.S.F. INTERIOR WIALL 10 P.S.F. (INCHES,w.c) ad COMMON NAILS (INCHES, o.c) M1501.3 CLOTHES DRYER DUCT: NOT TO EXCEED 25' (EXCLUDING TRANSITION DUCT) AND REDUCED 2 PROVIDE ALL LINTELS OR HEADERS NOT INDICATED ON DRAWINGS OVER ALL OPENIN65. HEADERS ' 502.11 WOOD TRU55E5 DE5I6N: WOOD TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH 4' PERIMETER EDGE ZONE 12 6 12 1. 1/2" FOR EVERY 45 DEGREES BEND AND V FOR EACH 110 DEGREES BEND. INSTALL BOOSTER FAN ARE TO BE EQUAL TO FULL WIDTH OF FRAMING (MIN. (2) 2" x 8") R3012.3 GROUND SNOWLOAD 45 P.S.F. STANDARD EN6INEERIN6 PRACTICE. THE TRU55 DE516N DRAWIN65 SHALL BE PREPARED BY A ib b 6 FOR ADDITIONAL LENGTHS. REGISTERED DESIGN PROFESSIONAL IN ACCORDANCE WITH SECTION RIO6.1. TRU55 DESIGN DRAWINGS INTERIOR ZONE 12 6 12 JOISTS HAN6AR5,ETC. TO BE MANUFACTURED BY "SIMPSON STRONG TIE COMPANY INC." OR EQUAL R301.4 MINIMUM UNIFORMLY DISTRIBUTED DE51ON LIVE LOADS: PREPARED IN GOMPLIANGE WITH SECTION R502.11.1 SHALL BE 50MITTED TO THE CODE ENFORCEMENT MI50b 3 EXHAUST FANS: IN BATHS WHEN REQUIRED TO HAVE MECHANICAL EXHAUST CAPACITY OF OFFICIAL PRIOR TO INSTALLATION. lb 6 12 1. M1 GFM INTERMITTENT : 20ATHOFM CONTINUOUS. FOR ALL FLUSH STRUCTURAL CONNECTIONS. EXTERIOR BALCONY 60 P S-F GABLE ENDWALL RAKE AND RAKE TRW55 4 4 WOOD DECK 40 P.S.F. R502.12 DRAFT5TOPPING: INSTALL 1/2" 6YP5UM BOARD OR 3/5" PLYWOOD OR PARTICLE BOAR P26015 WATER HEATERS: NOT INSTALLED ON SLAB SHALL BE INSTALLED IN A GALVANIZED STEEL ALL WINDOWS AND DOOR OPENINGS,UNLESS OTHERWISE INDICATED, SHALL HAVE STUDS DOUBLED L/240 ATTICS WITH 5TORA6EE: 20 P.S.F. PARALLEL TO OPEN WEB FLOOR JOIST WITH FINISHED TOP AND BOTTOM FLANGES EVERY 1,000 S.F. ARD ATH1N6 ON JAMBS. PAN HAVING A MIN L/360 FLOOR(NOT BEDROOMS): 40 P.5.F. OF CONGEALED 5PAGE. PROVIDE STOP MATERIAL AT SUSPENDED GEILIN65 UNDER FLOOR SHEATHING 51ZE RAFTER/TRU55'5PAGIN6 MINIMUM NUMBER OF ad . THICKNESS OF 24 GAUGE AND 11/2" DEEP PROVIDED WITH DRAIN LINE. PROVIDE GALVANIZED HURRICANE CLIPS AT ROOF RAFTER TO WALL CONNECTION AT ALL ! 1-/360 BEDROOM FLOORS: 30 P.S.F. FRAMING. L/I8o ROOF: 45 P.S.F. (GROUND SNOW LOAD) (INCHES,w.c) COMMON NAILS PER SUPPORT CATHEDRAL AND TRAY CEILINGS. U240 ATTICS WITH FIXED STAIRS: 30 P5.F. R503.1 5HEATHING: I"x 6"OR I"x S'SHNEATHING 12 - Iq 2 GENERAL PERFORMANCE NOTES SUBFLOORIN6: I6" O.G. SUPPORT (5/8") MIN. I"x 10'OR LARGER SHEATHING 12 - iq.3'3 3 ALL FLOOR JOISTS SHALL BE CROSSBRID6EED WITH 5/4" X 3" BRID61N6 AT MIDSPAN OR INTERVALS R303(I) HABITABLE ROOM VENTING: WINDOW OPIENIN6 MIN. 4% OF FLOOR AREA OR MECHANICALLY 24" O.G. SUPPORT (3/4") MIN. E - NAIL 5PAGING AT PANEL EDGES (In) NOT TO EXCEED 8'. (OR SOLID WOOD BLOCKING ® MIDSPAN). ALL CONSTRUCTION SHALL COMPLY FULLY WITH THE APPLICABLE PROVISIONS OF THE NEW YORK VENTED PRODUGIN6 0.35 AIR CHAN6E PER HOUR! EXCEPT BEDROOMS AND FINISHED BASEMENTS. ROOF 5HEATHING: 16" O.G. SUPPORT(1/2") MIN. F - NAIL 5PAGING AT INTERMEDIATE SUPPORTS IN THE PANEL FIELD (In) STATE RESIDENTIAL BUILDING CODE AND OSHA. THE TOP AND BOTTOM EDGES OF JOISTS MAY NOT BE NOTCHED TO EXCEED 2". TABLE R O.G. SUPPORT (5/8") MIN. I. TABULATED 12 INCH o.c. NAIL 5PAGING ASy5UME5 5HEATHING ATTGHED TO RAFTER/TRU55 FRAMING R303(2) HABITABLE ROOM LIGHTING: GLAZING N�IN. SSK OF FLOOR AREA OR ARTIFICIAL LIGHT OF WALL SHEATHIEATHI NG:: (1(I/2") MIN. CONTRACTORS SHALL VERIFY ALL JOB AND FIELD CONDITIONS,AFFECTING ALL WORK, AND OBTAIN PROVIDE A MINIMUM DOUBLE STUD POST AT ALL BEAM SUPPORTS. SEE PLAN FOR LARGER POST b FOOT CANDLES AT 30" ABOVE FLOOR. MEMBERS WITH 6�0.41. FOR FRAMING MEHOER5 WITH .042S6<0.4q, THE NAIL SPACING SHALL BE ALL DIMENSIONS TO INSURE THE PROPER STRENGTH, FIT AND LOCATION OF THE WORK. REPORT IN SIZES A5 INDICATED. ' SEE NAILING 5GHEDULE TABLE R602.3(I) 8 (2) FOR FA5TENIN6. ALL ROOF AND WALL PLYWOOD REDUCED TO b INCHES o.c. WRITING TO THE ARCHITECT AND ENGINEER ANY AND ALL CONDITIONS WHICH MAY INTERFERE WITH f R303.6 HABITABLE ROOM HEATING CAPABLE OF! MAINTAINING MINIMUM 68 DEGREES AT A POINT 36" PANELS SHALL BE EXTERIOR 6RADE, WITH EXTERIOR GLUE,SHALL MEET THE REQUIREMENT5 OF THE OR OTHERWISE AFFECT, OR PREVENT, THE PROPER EXECUTION AND COMPLETION OF THE WORK. DO NOT PLACE MARBLE OR STONE FLOORINI6 ON ANY AREA UNLESS SPECIFICALLY NOTED FOR LATEST EDITION OF THE U.S. PRODUCTS PS i AND SHALL BE IDENTIFIED WITH THE APPROPRIATE WALL 5HEATHING ATTACHMENT' REOUIRMENT51=0R WIND LOADS THAT ON PLAN. ABOVE FLOOR AND 24" FROM EXTERIOR WALL. GRADE TRADEMARK OF THE AMERICAN PLYWOOD ASSOCIATION. REPRODUCTION OF THESE PLANS, IN ANY FORM,WITHC�JT WRITTEN CONSENT OF THE ARCHITECT, 15 R305.1 MINIMUM GEILIN6 HEICHT5: T-b" MIN. IN HABITABLE ROOMS. TABLE 3.41 PROHIBITED. THESE PLANS MAY NOT BE FILED FOR CONSTRUCTION PURPOSES IN ANY BUILDING PROVIDE TOP FLANGE METAL JOIST HAN6EFZ5 AT ALL FLUSH FRAMED BEAM AND J015T MINIMUM BASEMENT HEICHT5: 'I'-O" MIN. 6-8" MIN.. UNDER 61RVER5, DUCTS, ETC, PLYWOOD SHEATHING TO RUN CONTINUOUS 12" MINIMUM PAST TOP AND BOTTOM PLATES OF ALL 110 MILE WINlD SPEED (mph) DEPARTMENT, WITH OUT THE ARCHITECT'S WRITTEN AUTHORIZATION AND/OR SEAL. ANY USE OF CONNECTIONS. EXTERIOR WALLS. IF PLYWOOD STOPS AT PLATE, THEN PROVIDE SIMPSON LSTA IS STRAPS AT 45" 5T1�GT!l &5HEA7fW Or PAS.VDIN62 THESE PLANS FOR ANY PURPOSES OTHER THAN THAT SPECIFICALLY AUTHORIZED BY THE R_: 8O #6) GLAZING IN HAZARDOUS LOCATION5: ALL GLAZING WITHIN 24" OF HINGED DOOR IN O.G. AND CORNERS, NAILED TO STUDS WITH IOD NAILS IN HOLES PROVIDED. CENTER STRAPS ON ARCHITECT, 15 ILLEGAL,AND MAY BE SUBJECT THE USER THEREOF TO THE PAYMENT OF FULL INSULATION IN THE EXTERIOR WALLS AND CEILING OF ALL HEATED 5PAGE5 SHALL BE CLOSED POSITION MUST HAVE SAFETY GLAZING IUNLESS SILL HEIGHT IS 60" ABOVE FLOOR. PLYWOOD JOINT. USE L5TA30 STRAP IF PLYWOOD DOES NOT OVERLAP BOTH THE TOP AND E I F COMMISSIONS. FIBERGLASS BATTS,51ZE A5 INDICATED ON DRAWINGS, WITH A VAPOR BARRIER ON THE HEATED BOTTOM PLATES AT THE SAME FLOOR LEVEL. INSTALL SHEATHING HORIZONTALLY AT FIELD AND 5HEATHIN5 LOCATION • STUD 5PAGIN6 MAXIMUM NAIL 5PAGING FOR SIDED. PACK ALL SPACES AROUND WINDOH5 AND DOORS WITH INSULATION. R308.4(10) 5TAIRWELL WINDOWS: WINDOW SILLS, AT STAIR LANDIN65 LESS THAN 60" SHALL HAVE VERTICALLY AT CORNERS. (INCHES,oz) 8d COMMON NAILS (INGHE5, o.a) FOR SITE PLAN LOCATIONS AND DETAILS, PAVING, WALKS, ETC. SEE DRAWINGS PREPARED BY SAFETY GLAZING. CONSULTING ENGINEERS. INSULATION IN CATHEDRAL GEILIN65 SHALL 1BE AS INDICATED ON DRAWINGS. CARE SHALL BE SUBFLOORING SHALL BE INSTALLED WITH FACE GRAIN ACROSS SUPPORTS;BREAK JOINTS IN 4'EDGE ZONE 12 6 12 TAKEN TO MAINTAIN THE FREE PA55AGE OF AIR BETWEEN INSULATION AND ROOF DECK (2" MIN) R30q.1 DOORS FROM GARAGE INTO HABITABLE ;SPADE: 45 MIN. FIRE-RATED WITH SELF-GLOSI G ADJACENT COURSES;LOCATE END JOINTS OVER SUPPORTS AND DRIVE NAILS FLUSH OR 5LI6HTLY 16 6 12 THESE PLANS ARE IN CONFORMITY WITH THE ONE AND TWO FAMILY CODE PROVISION5 OF THE WITH BAFFLES. f DEVICE. BELOW SURFACE. UNDERLAYMENT,WHERE REQUIRED,SHALL BE SIMILARLY INSTALLED. INTERIOR ZONE 12 6 12 RESIDENTIAL CODE OF NEW YORK STATE. Ib 6 12 ALL WOOD SHEATHING ON EXTERIOR WALLS AND ROOF SHALL BE COVERED WITH ONE LAYER R30g2.1 6ARA6,E WALL: 5/,V1 TYPE-X GYPSUM E3OARD ON GARAGE SIDE. 1/2" TYPE-X GYPSUM ROOF 5HEATING SHALL BE LAID WITH FACE GRAIN AT RIGHT ANOEL5 TO SUPPORTS;LOCATE END THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS,TECHNIQUES, OF #15 WATER PROOF BUILDING PAPER. BOARD ON OPPOSITE WALL SIDE AT HABITABLE AREAS. JOINTS OVER SUPPORTS;STAGGER JOINTS;PROVIDE METAL H CLIP AT JOINTS AT SIDES OF PANELS BOARD SHEATHING or LAP 51DIN5 5EQUENGE5 OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PR06RAM5 IN CONNECTION WITH WHEN 5PAGIN6 OF SUPPORTS 15 24" O.G. SHEATHING 51ZE STUD SPAC,lNG MINIMUM NUMBER OF ad THE WORK, THE ARCHITECT WILL NOT BE RESPONSIBLE FOR ANY CONTRACTOR'S OR ALL WALLS AND CEILINGS SHALL BE FINISHED WITH 1/2" GYPSUM WALLBOARD EXCEPT AS ' R301122 GARAGE CEILING: 5/5" TYPE-X 6YP5UIM BOARD. SUBCONTRACTOR'S FAILURE TO CARRY OUT THE WORK IN,rn.c ACCORDANCE WITH THESE PLANS AND INDICATED OTHERWISE ON DRAWINGS. USE WATERPROOF TYPE IN AREAS OF MOISTURE. [TAPE AND ALL FLOORS TO BE COVERED WITH CARPET SHALL HAVE (I) LAYER I/4" UNDERLAYMENT BOARD OR (INCHES, COMMON NAILS PER SUPPORT FURTHER, ALL SUCH CONTRACTORS AND SUBCONTRACTORS HEREBY EXCULPATE THE ARCHITECT SPACKLE(5) COATS]. R310.1 FINISHED BASEMENTS: EORE55 WINDOW5 SILL HEIGHT MAX 44" ABOVE FLOOR. OTHER APPROVED EQUAL,OVER SUB-FLOOR, FLOORS TO BE COVERED WITH OAK FLOORING, I"x 6"OR I"x 6"5HEATHIN5 12 -241 2 FOR LIABILITY WHATSOEVER OCCASIONED BY SUCH FAILURE. { GRANITE OR CERAMIC TILE SHALL HAVE LAYER OF 23/32 SUB-FLOORING. I'x 10'OR LARGER 5HEATHING 12 -24E 3 GLAZING IN DOORS,SHOWER DOORS 4 ENCLOSURES, ADJOINING DOORS + BATH TUB5 + R310.1.1 WINDOW EGRESS OPEENING REQUIREMENTSi: NET CLEAR OPENING FIRST FLOOR 5.0 5.F., ALL REQUIREMENTS SPECIFIED IN THE CODE SHALL BE ADHERED TO A5 IF THEY WERE GALLED FOR, E - NAIL 5PAGING AT PANEL EV6E5 (In) ENGL05URE5,SHALL BE 50 SIZED,CONSTRUCTED, TREATED,OR COMBINED WITH OTHER MATERIALS SECOND FLOOR 5.71 S.F. MIN. HEIGHT OPENING 23,4",MIN. WIDTH OF OPENING 20". R602.32 WALL DOUBLE TOP PLATE END JOINTS TO OFFSET MIN. 24". OR SHOWN,ON THE DRAWINGS. THIS SHALL NOT BE CONSTRUED TO MEAN THAT ANY REQUIREMENTS AS TO MINIMIZE EFFECTIVELY THE POSSIBILITY OF INJURY TO MR5ON5 IN THE EVENT THE GLAZING F - NAIL 5PAGING AT INTERMEDIATE 51JPFIORTS IN THE PANEL FIELD (In.) SET FORTH ON THE DRAWIN65 MAY BE MODIFIED BECAUSE THEY ARE MORE 5TFIN6ENT THAN THE 15 CRACKED OR BROKEN. R310.12 EORE55 BASEMENT WINDOW WELL5: MIN. NET CLEAR AREA TO BE 36 x 36 . PROVIDE R602.3.3 BEARIN6 STUDS: WALL STUDS TO BE WITHIN 5" MAX. UNDER BEARING MEMBERS UNLE55 (2) CODE REQUIREMENT5 OR BECAUSE THEY ARE NOT 5PECIFICALLY REQUIRED BY CODE, STEPS OUT OF WELL IF BASE: HEIGHT TO GRADE EXCEEDS 44". Vxb" OR(3) 2'x4" PLATES ARE INSTALLED. I. FOR WALL 5HEATHING WITHIN 4 FEET OF THE CORNERS, THE 4 FOOT EGDE ZONE ATTACHMENT THE ELECTRICAL INSTALLATION SHALL CONFORM TO ALL LAWS AND ORDINANCES OF THE NATIONAL REQUIREMENTS SHALL BE USED. DO NOT SCALE THE DRAWINGS,ANY DISCREPANCIES SHALL BE REPORTED, IN WRITING,TO THE ELECTRONIC CODE,THE LIPA(LONG ISLAND POWER AUTHORITY),LOCAL MUNICIPALITIES AND R312.12 LANDIN65 AT DOORS: MIN. 36" x 56" LANNOIN6 REQUIRED IF 3 OR MORE RI5ER5 REQUIRED. TABLE R502.3(1) NAILING/FA5TENING SCHEDULE: ALL FRAMING SHALL BE PROVIDED AND SECURED 2• FOR EXTERIOR PANEL SIDING, GALVANIZEfP BOX NAILS SHALL BE PERMITTED TO BE SUBSTITUTED ARCHITECT FOR CLARIFICATIONS. THE REQUIREMENTS OF THE NEW YORK BOARD OF FIRE UNDERWRITERS. TO SUPPORTING MEMBER5 IN STRICT ACCORDANCE WITH RECOMMENDED NAILING SCHEDULE FOR COMMON NAILS. R313.1 RAMPS: MAX SLOPE ONE UNIT VERTICAL T:O 8 UNITS HORIZONTAL (I IN 8 SLOPE). PROVIDE INCLUDED IN THESE SPECIFICATIONS OR AS HEREAFTER NOTED. GENERAL CONTRACTOR SHALL COORDINATE FOR EASE AND RAPIDITY OF CONSTRUCTION THE WORK AT LEAST ONE SINGLE STATION SMOKE DETECTING ALARM DEVICE, INSTALLED IN CONFORMITY HANDRAIL ONE SIDE FOR SLOPES THAT EXCEED I IN 12. OF ALL TRADES. ALL SLOTS,SLEEVES AND/OR OTHER OPENINGS TO BE COORDINATED AND SET WITH SECTION A510, SHALL BE PROVIDED IN EACH SLEEPING SPACE, ON EACH FLOOR LEVEL AND NAILING 50HEDULE BEFORE POURING CONCRETE. R314.1 STAIR: STAIR WIDTH MIN 36" WITH MIN. CLLEAR OPENING 31.6" WITH HANDRAIL ONE 51DE AND R602B(I-5) FIREBLOGKING: FIREBLOGK ALL CONGEALED DRAFT OPENINGS (VERTICAL AND ! SHALL BE LOCATED ON OR NEAR THE GEILINUG. .�( TABLE 3.1 HORIZONTAL) BETWEEN STORIES AND TOP STTORY OPEN TO ATTIC, SPACE. FIRESTOP MATERIAL TO CONTRACTOR SHALL PROVIDE ALL THE NECESSARY SUPPORT, BRACING, SHORING ETC. (TEMPORARY 2'1" HANDRAIL BOTH SIDES. BE WOOD BATES OR BLANKETS SECURELY (RETAINED IN PLACE PER SECTIONS R602.8(I), (I.I) AND ALL PLUMBING FIXTURES SHALL BE INDIVIDUALLY TRAPPED AND VENTED A5 REQUIRED BY THE R3142 TREADS 4 RISERS: MAX. RISER HEIGHT 13 1/4'. MIN TREAD DEPTH q" PLUS NOVNG5 1/4" - i JOINT DESCRIPTION NUMBER OF NAILS NAIL 5PAGING AND/OR PERMANENT) A5 REQUIRED FOR THE SAFE INSTALLATION OF NEW CONSTRUCTION. (1.2). CODE (Nl'5 CODE). CAST IRON PIPE SHALL CONFORM WITH LOCAL GODS REQUIREMENTS, WITH 114" MAX. OPEN RISERS NOT PERMITTED ON R15E5 GREATER THAN 30". MAX. 515" TREAD AND ROOF`: SRAM IN C EXCAVATE FOR ALL FOOTINGS FOUNDATION WALLS AND SUCH OTHER WORK A5 MAY BE APPROVED JOINTS, PIPE SUPPORTS AND GLEANOUTS. RISER VARIANCE WITHIN STAIR RUN. MIN. TREAD WIDTH OF 6" ON WINDERS. RAFTER TO TOP PLATE (TOE-NAILED) 3 - ad PER RAFTER R702 3 GYPSUM BOARD: INSTALL OVER 2'." NOMINAL WOOD FRAMING OR Ix2 FURRING STRIPS ® NIECE55ARY TO THE DEPTHS A5 SHOWN ON THE DRAWINGS. ALL TRENCHES FOR FOOTIN65 ' 24" O.G. MAX. PREVENT EXPOSURE TO WEATHER ATTACHING GYPSUM BOARD TO WOOD FRAME AS FOUNDATIONS, ETC., SHALL HAVE LEVEL,SOLID AND UNDISTURBED BOTTOMS. ALL GUTTER5 TO BE SEAMLESS ALUMINUM WITH 5" BAKED ENAMEL FINISH. GEILIN6 J015T TO TOP PLATE (TOE-NAILED) 3 - ad PER JOIST FOLLOWS (UNLESS NOTED OTHERWISE). SCREWS SHALL BE 5 OR HAND PENETRATE WOOD 5/8" MIN. , R314.3 STAIR HEADROOM: MIN. 6'-5" MEASURE VERTICAL. GEILIN6 JOIST TO PARALLEL 3 - Ibd EACH LAP 12" D.G. FOR GEILIN6 AND 16" O.G. FOR WALLS. NAILING TO GEILIN6 WOOD FRAME TO BE 1" O.G. ALL SOIL BEARING CAPACITY ASSUMED a 2 TOWS.F. O.C. SHALL VERIFY IN FIELD. ALL CLOSETS TO RECEIVE WOOD SHELVES AND HANG RODS, TYPICAL UNLESS OTHERWISENOTED. R315 HANDRAILS: PROVIDE 34" - 55" HIGH HANDRAIL ON AT LEAST ONE 51DE OF STAIRWAY WITH 2 RAFTER(FACE-NAILED) AND 8" O.G. AT WALLS. OR MORE RISERS. CEILING JOIST LAPS OVER 3 - Ibd EACH LAP R1032 ASPHALT SATURATED FELT: 15 POUNDS PER 200 S.F. APPLIED HORIZONTALLY WITH THE ALL CONCRETE SHALL BE 5000 P.5.1. MINIMUM. PROVIDE VENTILATION FOR NONHABITABLE SPACE IN CONFORMITY WITH NEW YORK STATE CODE. R316 GUARDRAILS: PORCHES,BALCONIES AND STAIR LANDINGS 30 ABOVE FLOOR OR GRADE TO PARTITIONS(FACE-NAILED) UPPER LAYER LAPPED OVER LOWER MIN. 2"',LAPP 6" AT JOINTS MINIMUM. BE INSTALLED WITH 36" HI6H•1 RAILINGS, BALUSTEfRS NOT TO ALLOW PASSAGE OF A SPHERE 4" OR COLLAR TIE TO RAFTER(PAGE-NAILED) 3 - ad PER TIE HERE THE WALLS ARE POURED TO GRADE, AND DAMPPROOFED, THE CONTRACTOR SHALL HEAT PRODUCING EQUIPMENT SHALL BE M BAGKFILL AGAINST THEM WITH GLEAN EARTH. CARE SHALL BE TAKEN TO BRACE WALLS A5 OUNITED AND INSTALLED AS REQUIRED BY THE ' MORE IN DIAMETER. BLOCKING TO RAFTER (TOE-NAILED) 2 - Sd EACH END R103b EXTERIOR PLASTER REQUIRED TO PREVENT GAVE-IN5. BAGKFILL TO BE FREE OF WOOD, TRASH,ETC. RESIDENTIAL CODE OF NEW YORK. RIM BOARD TO RAFTER(END-NAILED) 2 - Ibd EACH END FLAMMABLE MATERIAL SHALL NOT BE PERMIITTED A5 INSULATION OR FILL IN CONGEALED OR R'f03b.i LATH - ALL LATH AND LATH ATTACHMENTS SHALL BE OF CORROSION-RESISTANT R31'1.1 SMOKE ALARMS: INSTALL SMOKE ALARMS IN ALL BEDROOMS AND IN IMMEDIATE VICINITY ALL CONCRETE FLOOR SLABS SHALL BE 4 THICK UNLESS OTHERWISE NOTED ON DRAWINGS. ATTIC SPACE AS NOTED IN NEW YORK 5TAT7= CODE SECTION 'flll-4B-4. OUTSIDE OF BEDROOMS. INSTALL ONE SMOKE ALARM ON EACH LEVEL INGLUDIN6 BASEMENT. W�.LL F=Rfi.MINO MATERIALS. EXPANDED METAL OR WOVEN WIRE LATH SHALL BE ATTACHED WITH I I/2 INCH-LONG FLOORS TO BE LEVEL UNLESS OTHERWISE NOTED ON DRAWINGS. INTERCONNECT ALL ALARMS. TOP PLATE TO TOP PLATE (FACE-NAILED) 2 - Ibd I PER FOOT (38 MM), II GAUGE NAILS HAVING-1116-INCH CII.I MM) HEAD,OR'US-INCH-LONG (22.2 MM), 16 GAUGE HEATING SYSTEM SHALL CONFORM TO THE RIEQUIREMENTS OF THE ENERGY CONSERVATION CODE STAPLES SPACED AT NO MORE THAN 6 INGIHES(152 MM). ALL FOUNDATION WALL FOOTINGS SHALL BE POURED CONCRETE: OF NEW YORK STATE. TOP PLATES AT INTERSECTIONS (FACE-NAILED) 4 - Ibd JOISTS - EACH SIDE R311.3 AUTOMATIC SPRINKLER SYSTEM: BUILDINCGS HAVING A HEIGHT OF 3 STORIES SHALL BE STUD TO STUD (FACE-NAILED) 2 - Ibd 24"o.c. 2'-O" W X 12" D ® 12" FOUNDATION WALL EQUIPMENT WITH AUTOMATIC SPRINKLERS IN AGC:I.ORDANCE WITH NIFPAI5PX. R7O3b2 PLASTERING WITH PORTLAND GEMIENT PLASTER SHALL BE NOT LE55 THAN THREE GOATS I'-5" W X 10" D ® 10" FOUNDATION WALL ALL OPERABLE WINDOWS (AS WELL AS DOORS) MAY BE USED FOR EMERGENCY USE AS A SPRINKLER SYSTEM IS NOT REQUIRED WHEN FIR5T STORY 15 BASEMENT WHERE THE FINISHED HEADER TO HEADER(FACE-NAILED) Ibd 16" o.c. ALONG E06E5 WHEN APPLIED OVER METAL LATH OR WIRE LATH AND SHALL BE NOT LESS THAN TWO GOATS WHEN I'-4" W X 5" D a 8" FOUNDATION WALL REQUIRED BY THE RESIDENTIAL CODE OF NEW YORK STATE. FLOOR ABOVE BASEMENT IS: TOP OR BOTTOM PLATE TO STUD(END NAILED) 2 - Ibd PER 2 x 4 STUD APPLIED OVER MASONRY,CONCRETE, OR 6,YPSUM BACKING. IF THE PLASTER SURFACE 15 MORE THAN 6 FEET ABOVE GRADE FOR 50% OR: MORE. COMPLETELY COVERED BY VENEER OR OTHER FACING MATERIAL OR 15 COMPLETELY CONGEALED STORM WATER FROM ROOF TO BE DISPOSED OF IN A PROPER MANNER AS REOUIRED BY HEALTH 3 - 1(od PER 2 x 6 STUD PLASTER APPLICATION NEED BE ONLY T HO GOATS, PROVIDE THE TOTAL THICKNESS AS SET FORTH DEPARTMENT, LOCAL BUILDING DEPARTMENT AND ALL OTHER AGENCIES L HAVING JURISDICTION. HAND RAILINGS,BOTH INTERIOR AND EXTERIOR SHALL DESIGNED TO RESIST A LATERAL MORE THAN 12 FEET AT ANY POT. IMPACT AT THE TOP EQUIVALENT TO A MINIMUM LINEAR LOAD OF 50 POUNDS PER FOOT. REFER TO MORE THAN 6 FEET ABOVE G 4 - Ibd PER 2 x 8 STUD GRADE PLANE. I� IN TABLE R702.1(I). FLUE LININGS SHALL BE OF TERRA GOTTA, EXTENDING FULL HEIGHT THROUGH THE CHIMNEY GAP. RESIDENTIAL CODE OF NEW YORK STATE. BOTTOM PLATE TO FLOORJO15T,BANDJO15T, 2 - Ibd PER FOOT R323.12 ALL SILLS AND PLATES ON EXTERIOR FOUNDATION WALL TO BE PRESSURE ENDJOIST OR BLOCKING (FACE-NAILED) ON WOOD-FRAME CONSTRUCTION WITH AN OPN-GRADE FLOOR SLAB SYSTEM, EXTERIOR PLASTER CONSTRUCTION OF STAIRS SUCH A5 RISER AND TREAD SIZE,H1=16HT OF HANDRAIL ABOVE PRE5ERVATIVELY TREATED. SHALL BE APPLIED IN SUCH A MANNER A5 Tf0 COVER, BUT NOT EXTEND BELOW,LATH, PAPER, AND ALL FIREBOXES SHALL BE LINED WITH FIRE BRICKS AS PER ASTM GIOb. TREAD SHALL COMPLY WITH THE REQUIREMENTS SET FORTH IN THE RESIDENTIAL CODE OF 1=L00M 1=KAM IN Cov SCREED. R323.15 ALL SILLS AND SLEEPERS ON SLAB TO BE PRESSURE TREATED UNLESS IMPERVIOUS MOISTURE JOIST TO SILL, TOP PLATE 4 -5d PER JOIST PROVIDE COMBUSTION AIR VENTS PER ENERGY CODE. NEW YORK STATE. BARRIER UNDER SLAB IS INSTALLED (11ZEATMENIT OF WOOD IN ACCORDANCE WITH AWPA 022). THE PROPORTION OF AGGREGATE TO GEMEENTITIOU5 MATERIALS SHALL BE A5 SET FORTH IN TABLE A 2ND.�JBM/55/ON RE✓l5E /�2��OR GIRDER(TOE-NAILED) THE EXTERIOR SURFACE OF ALL FOUNDATION WALL5 BELOW GRADE (EXCEPT SLAB AREAS) SHALL BREEZEm)eI*X/O' R323.1.4 FOUNDATION WOOD GIRDERS: WOOD 611RDER5 SEATED IN EXTERIOR FOUNDATION WALLS BRIDGING TO JOIST(TOE-NAILED) 2 - ad EACH END RT02.1(3). BE DAMPPROOFED WITH AN ELASTIC COAL TAR BASE,SELF PRIMING BITUMINOUS PLASTIC CEMENT. TO HAVE MIN. 1/2" AIR-SPACE ALL SIDES OR ENDS WRAPPED WITH ALUMINUM FLA5HIN6. BLOCKING TO JOIST(TOE-NAILED) 2 - ad EACH END R'703.71 STONE AND MA50NRY VENEER, 6EMIERAL: ALL STONE AND MASONRY VENEER SHALL BE MARK �� DATE BLOCKING TO SILL OR TOP PLATE(TOE-NAILED) 3 - Ibd EACH BLOCK INSTALLED IN ACCORDANCE WITH TH15 CHAPTER,TABLE R'103.4 AN FIGURE R703.'1. SUCH VENEERS MASONRY CONCRETE WALL ROD REINFORCEMENT SHALL BE INTERMEDIATE GRADE DEFORMED R323.3 FASTENERS FOR PRE:55URE TREATED W0100: HOT DIPPED 6ALVANIZED STEEL, STAINLESS LEDGER STRIP TO BEAM(FACE-NAILED) 3 - Ibd EACH JOIST INSTALLED OVER A BACKING OF WOOD OR 1 GOLD-FORMED STEEL SHALL BE LIMITED TO THE FIRST BARS, CONFORM TO A5TM AI540 REINFORCING MESH SHALL CONFORM TO A5TM A 155 AND A62. 5TEEL, 51LICON BRONZE OR COPPER OR 1 1/2" DIAMETER STEEL BOLTS. JOIST ON LEDGER TO BEAM (TOE-NAILED) 3 - ad PER J015T STORY ABOVE CRAVE AND SHALL NOT EXG:EEP 5 INCHES (121 MM) IN THICKNESS. PROVIDE METAL TERMITE SHIELD OF APPROVED TYPE DESIGN. IMXICHAI?L T. L.OGAN R401.4 FOOTIN05: SHALL BEAR ON UNDISTURBED INORGANIC SAND,GRAVEL CLASS 6W,GP,501L BAND J015T TO J015T (TOE-NAILED) 3 - Ibd PER J015T R103:1.3 LINTELS: MASONRY VENEER SHALLL NOT SUPPORT ANY VERTICAL LOAD OTHER THAN THE 27 T-ORLEN COURT,HAUPPAUGE,NY 11788 WI1H A MINIMUM BEARING GA:PACITY OF 5000 P.S.F. MEETING THE REQUIREMENTS OF SEISMIC SITE BAND JOIST TO SILL OR TOP PLATE(TOE-NAILED) 2 - Ibd I I PER FOOT DEAD LOAD OF THE VENEER ABOVE. VENEEER ABOVE OPENINGS SHALL BE SUPPORTED ON LINTELS ALL STRUCTURAL STEEL SHALL BE NEW AND CONFORM TO ASTM A3b OR A5TM A376. 6311 979-2129 GLASS D OR BETTER PER TABLE 1615.11 OF NY5 MILDING CODE. ROOF= SHI✓ATH1 N6 OF NON-COM5U5TIBLE MATERIALS AND THE ,ALLOWABLE SPAN SHALL NOT EXCEED THE VALUES SET THE DESIGN, FABRICATION AND ERECTION OF ALL 5TRUCTURAL STEEL, SHALL BE IN ACCORDANCE FORTH IN TABLE R703.T.3. THE LINTELS SHALL HAVE A LENGTH OF BEARING ON NOTE LESS THAN 4 R4022 CONCRETE: A MINIMUM COMPRESSIVE 57RENGTH 15 REQUIRED AT THE FOLLOWING STRUCTURAL PANELS 8d SEE TABLE 38 INCHES (102 MM). WITH THE LATEST EDITION OF THE AISG 5PEGIFIGATIONS. ARCHITECT LOCATIONS AS DETERMINED BY TABLE R402.2 ('SEVERE WEATHERING COLUMN), PROVIDE 5% AIR DIA60NIAL BOARD SHEATHING TTABLE R103:1.3 SHOP AND FIELD CONNECTIONS SHALL BE WELDED,OR MACHINE BOLTED,WITH ASTM 233 E70 PLANNER ENTRAINMENT IN ALL CONCRETE. (5000 P.S.I. MINIMUM) I" x b" OR I" x 8" 2 -ad PER SUPPORT ALLOWABLE SPANS FOR I LINTELS SUPPORTING MASONRY VENEER A SERIES ELECTRODES AND A50T BOLTS WITH LOCKS AND WASHERS, RESPECTIVELY. I" x 10" OR WIDER 3 - ad PER SUPPORT R403.16 ANCHOR BOLTS: SILL PLATES TO BE ANNGHORED WITH 5/8 VIA. x MIN. 12 L ANCHOR 51ZE OF NO STORY ONE STORY TWO STORY NO. OF 1/2" OR EQUIVALENT BOLTS MAX. 45" O.G. AT ONE STORY STRUCTURE', AND MAX. 24" O.G. AT T HO STORY STRUCTURE GE I L I N0o 5HP-ATH I N� STEEL ANGLE°1' ABOVE ABOVE ABOVE REINFORCING BAR5b ALL STRUCTURAL WELDING SHALL BE PERFORMED BY WELDERS CERTIFIED IN COMPLIANCE WITH WITHIN 12" FROM ENDS OF EACH SILL PLANE PIECE. USE DOUBLE SILL AND STA66ERED JOINTS. GYPSUM WALLBOARD 5d COOLERS I" EDGE/ 10" FILED AMERIGAN WELDING SOCIETY'S STANDARD QUALIFICATION PROCEDURES. 3 x 3 x 1/4 (Inches) 6'-0" 3'-b" 3'-O" I PROJECT EXTEND BOLTS MIN. T" INTO FOUNDATION: A NUT AND WASHER SHALL BE TIGHTENED TO EACH BOLT. iNALL SHF-ATHING 4 x 3 x 1/4(Inches) 8'-O" 'S'•0" 3'-O" 1 ALL LUMBER DELIVERED AND STORED AT PROJECT SITE SHALL BE PROTECTED FROM THE WEATHER KUILICK RESIDENCE SEE PLANS FOR LOCATIONS OF HOLD DOWNS REQUIRING ANCHOR BOLTS. STRUCTURAL PANELS ad SEE TABLE 3.9 WITH A TARPAULIN OR HEAVY GAUGE PLASTIC. ALL WOOD MATERIAL SHALL BE STOCKPILED ON 18915 MINNEHAHA BOULEVARD R405.1 FOUNDATION DRAINAcSE: INSTALL DRAINS AROUND FOUNDATION, RETAINED EARTH AND FIBERBOARD PANELS 6 x 3 1/2 x 1/4(Inches) 14'-O" 18'-O"�l -3'-6" 2 WOOD DUNNAGE, IN A RELATIVELY FLAT,DRY AREA. THE SAME PROTECTION SHALL BE PROVIDED ENCLOSE HABITABLE SPACE LOCATED BELOW 61RADE. DRAIN SYSTEM NOT REQUIRED IN 't/I6" bd 3" EDGE/6" FIELD 2-6 x 3 I/2 x I/4 (Inches) 20'-O" il'•0" 5'-O" 4 DURING SHIPPING AND INSTALLATION. SOUTHOLD, NY 11971 ," "1 SAND-GRAVEL MIXTURE 5011.5 PER GROUP I SOILS, TABLE R405.1. 25/32" Sd 3" EDGE/6" FIELD FOR 51: I INCH=25.4 MM I FOOT=304.8 NMM ALL CARPENTRY WORK SHALL BE PERFORMED IN CONFORMANCE WITH COOP TRADE PRACTICE. R406.1 DAMPROOF/WATERPROOF FOUNDATIONS: (SEE CODE SECTIONS R406.1 - 406.5.2 FOR GYPSUM WALLBOARD 5d COOLERS 7" EDGE/ 10' FIELD a. LONG LEO OF THE ANGLE SHALL BE PLAC:ED IN A VERTICAL POSITION. RECOMMENDATIONS OF MANUFACTURERS AND IN CONFORMANCE WITH THE NEW YORK STATE ` '. NOTES , 'r f I 1L vi HARDBOARD ad SEE TABLE 5.4 b. DEPTH OF REINFORCED LINTELS SHALL NCOT BE LE55 THAN 5 INCHES AND ALL CELLS OF HOLLOW BUILDING CODE, INGLUDIN6 THE FOLLOWING: 11. a LOCATION REQUIREMENTS). MASONRY LINTELS SHALL BE GROUTED SCOLID. REINFORCING BARS SHALL EXTEND NOT LESS THAN FASTEN SECURELY ALL PARTS OF CARPENTRY WORK IN THEIR PROPER PLACE, BRACE PLUMB AND t., R406.3 POROUS FILL: BACK WITH THE SAME MATERIAL L15ED FOR FOOTINGS,UP TO HEIGHT OF PARTICLEBOARD PANELS ad SEE TABLE'.3.q 8 INCHES INTO THE SUPPORT. LEVEL ALL MEMBERS AND SECURE WITH SUFFICIENT MAILS, SPIKES AND BOLTS TO INSURE RIGIDITY. ' " ' . �:� I'-0" ABOVE FOOTING FOR WELL DRAINED SITES„ OR I/2 THE TOTAL BAGKFILL HEIGHT FOR POORLY DIAGONAL BOARD 5HEATHING c. STEEL MEMBERS INDICATED ARE ADEOUAITE TYPICAL EXAMPLES;OTHER STEEL MEMBERS MEETING . , W DRAINED SITES. COVER POROUS FILL WITH STRAPS OF 30LB ASPHALT PAPER OR 6-MIL I" x b" OR I" x 8" 2 - ad PER SUPPORT STRUCTURAL DE516N REQUIREMENTS MAY BE USED. PROVIDE AT LEAST DOUBLE JOISTS AND HEADERS I WATER CLOSET DRAIN BENDS AND AT ALL JOB NO, • VENTS AND MECHANICAL OPENINGS 2' OR MORE IN WIDTH UNLESS OTHERWISE SHOWN ON THE DRAWINGS. �� ~� �'��'�•A,.*�w„�'° �d��g POLYETHYLENE TO PERMIT WATER SEEPAGE ANID AVOIDING FINE SOILS INFILTRATION. I" x 10" OR WIDER 2 - ad PER SUPPORT - �1' R103.41 EXTERIOR INSULATION FIN15H 5Y5TEMIS,6ENERAL: ALL EXTERIOR INSULATION FINISH ALL DOORS d WINDOWS SHALL HAVE HIGH PERFORMANCE IMPACT GLAZING AS PER 120 MPH ;r I, `` �, SYSTEMS (EIFS) SHALL BE INSTALLED IN ACCGORDANGE WITH THE MANUFACTURER'S INSTALLATION HIN05FEED REQUIREMENTS 4 TESTS. . ,' - "` DATE' //�,2/�O6 DRAWIN05 ,SPECIFICATIONS AND OTHER DOCUMENTS PREPARED BY THE ARCHITECT INSTRUCTIONS AND THE REQUIREMENTS OF TFHI5 SECTION. DECORATIVE TRIM SHALL NOT BE FACE - ARE THE INSTRUMENTS OF THE ARCHITECT'S SEIRVICE AND SHALL REMAIN THE NAILED THROUGH THE EIFS. THE EIFS SHALL. TERMINATE NOT LESS THAN b INCHES (152 MM) ABOVE ALL DOORS AND WINDOWS SHALL HAVE CORROSION RE515TANT COMPONENTS. BCALJE /�S NOTED PROPERTY OF THE ARCHITECT,WHIETHER OR NOT THE PROJECT FOR WHICH THEY ARE INTENDED T2 15 CONSTRUCTED OR NOT. THE ARCHITECT'S DRAWINGS, SPECIFICATIONS AND OTHER DOCUMENTS WILL NOT BE USED ON ANY OTHER PROJECTS FOR ADDITIONS TO THE FINISHED GROUND LEVEL. THIS PROJECT AND/OR FOR COMPLETION OF THIS PROJECT BY OTHERS, EXCEPT DY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO THE ARCHITECT. GOB RI�,>�T 2006 [)RAVWN By W. MARRA INTERMEDIATE BEARING LOAD BEARING OR SHEAR WALL ALLOWABLE HOLES - TJI@ Joists LOAD BEARING OR SHEAR NO LOAD BEARING WALL ABOVE: ABOVE (MUST STACK OVER WALL FOR INFORMATION ON LATERAL WALL ABOVE (MU5T STACK BELOW WHEN PRESENT) LOAD CAPACITIES, REFER TO OVER WALL BELOI^) WEB STIFFENERS No field LOAD FROM Do not cut holes larger BLOCKING CURRENT TRU5 J015T RIM REQUIRED EACH 51ME AT ABOVE cut holes than 1Y2"In cantilever No field out C BLOCKING PANEL BLOCKING See table See table PANEL_ BOARD LITERATURE. " B3W BLOCKING PANELS PANEL in Notched See table holes in Maintain ade vate See table hatched zone q F A 2 x 4 MINIMUM MAY BE RUES R B WITH ( ��--.� kb -1 distance from SQUASH BLOCKS SHEAR WALlLS ABOVE OR --� bearings BELOW - SEE DETAIL BI i O O 6" 6" END (/ 46" JOISTS AT AT Di 2xD2 02 L2 2 x L2 LI BI BIw � CENTERLINE 6" 6" m►nimum minimum 6" -- ly2" hole (also applies t ica OF SUPPORT 2" x 4" MINIMUM pp yp TRU5 JOIST WEB STIFFENERS may be cu to IV2" holes) TJI®RIM JOIST SQUASH BLOCKS RIM 3WARD REOUIRES EACH anywhere In web outside Out holes with care SIDE AT BIN AND MUST HAVE 13/4" MINIMUM �3 MUST HAVE 13/4" MINIMUM B2W USE 2" x 4" MINIMUM SQUASH hatched area, and In the joist web B4 JOIST BEARING AT ENDS JOIST BEARING AT ENDS BLOCKS TO TRANSFER LOAD only B2 B2W B3 B3H G5 FROM ABOVE TO BEARING MINIMUM DISTANCE FROM INSIDE FACE OF ANY SUPPORT TO NEAREST EDGE OF HOLE PLATE BELOW FOR OTHER LOAD CONDITIONS OR HOLE CONFIGURATION5 NOT INCLUDED IN TH15 TABLE, REFER TO TJ-BEAMo 5OFTWARE OR CONTACT YOUR TRU5 JOIST REPRESENTATIVE. JOIST TJI®IProTm ROUND HOLE SIZE SQUARE OR RECTANGULAR HOLE SIZE STIFFENERS DEPTH e „ a e .. " s " REQUIRED EACH 5" DIAMETER MAXIMIUM HOLE 4'-0" LENGTH OF b'-0" LENGTH OF TJIo NAIL TRU5 J015T RIM ATTACH REINFORCEMENT TO 2" 3" a" s" sY4 7" s/ s" 10/; 12" 2" 3" a" 5" sy;' T" s/ 9 10/" 12 51DE AT EIW FOR II3/a" - 20" J015IT5;6" s/4" REINFORCEMENT 6" DIAMETER MAXIMUM HOLE BEAM TO BEAM J015T REINFORCEMENT ATTACH BOARD TO BLOCKING JOIST TOP AND BOTTOM 1ooTS T-6" 2'-0" 2'-6" 3'-6" 5'-6" 1'-6" 2'-6" 3'-6" 5'-0" s'-o" DIAMETER MAXIMUM IFOR cty2" ON ONE 51DE AT FOR III/8" - 16" JOISTS;6" CONNECTION AND FILLER BLOCK. REINFORCEMENT TO WITH CONNECTIONS FLANGES WITH ONE 8D (2yZ") 130 2'-0" T-O" 3'-6" 4'-6" 7'-0" 2'-0" T-0" 4'-0" 6'-0" 7'-0" WEB 5" DIAMETER MAXIMUM HOLE JOISTS OR FOR BLOOGKIN6 E2, BOTH SIDES AT DIAMETER MAXIMUM FOR QY2" USE 4'-O" LENGTH WITH JOIST TOP AND EQUIVALENT TO COMMON NAIL AT EACH 150 2'-0° 3'-0° 3'-6° 5'-0° s'-s^ 2'-0° 3'-0° 4'-0° s'-o^ s'-s° E3 JOISTS OR FOR BLOCKING qY2" AND II'►/8' TJI0 FOR IIIY6" - I6" JOISTS;6" BOTTOM FLANGE5 WITH DECKING SCHEDULE CORNER 250 2'-0" 3'-6" 4'-6" 5'-6" T-O" 2'.0" 3'-6" 4'-6" s'-s" T-O" PANELS LESS THAN It2" LONG. PANELS LE55 THAN 12" LONG. JOISTS. DIAMETER MAXIMUM FOR Q1'2 ONE bV (214:2") COMMON 9Y2' 350 1'-6" 3'-6" 6-0" 6'-6" T-O" 1'-6" T-T 5'-0"1 6'-6" 7'-0" PO NOT GUT FLANGE.$. DO NOT OUT FLANGE5. JOISTS OR FOR BLOCKING NAIL AT EACH CORNER BLOCKING PANEL BETWEEN 100C 1'-6" 2'-0" 2'-6" 3'-6" 4'-6" 1'-6" 2'-0" T-0" 4'-0" 4'-6" PANELS LE55 THAN 12" LONG. EACH JOIST. NAIL TO TOP 300C 2'-6" 3'-0" 4'-0" 6-0" 6'-6" 2'-0" 3'-0" 4'-0" 6-6" 6'-6" DO NOT GUT FLANGE5. 12" LENGTH OF 5/4" PLATE WITH CONNECTIONS 400C 2'-0" 3'-0" 4'-0" 5'-6" 7'-6" 3'-0" 4'-0 5'-6" T-o" T-6" ATTACH REINFORCEMENT TO REINFORCEMENT ON EQUIVALENT TO DECKING 100TS 1'-0" 1'-6" 2'-0" 2'-6" T-O" 3'-6" 6'-0" 1'-6" 2'-0" T-O" 4'-0" 6'-6" 7'-0" 8'-6" J015T TOP AND BOTTOM ONE SIDE AT E5, • FLANGES WITH 8D (?Y2") COMMON ATTACH TJI JOIST BOTH SIDES AT E6 - SCHEDULE. 130 1 6 -2 0 2'-6 - -3 6' 4 6' 5-0 - -8 0' 2'.0" -3 0' 3-6' 6-0" 7-6 -8 0' 9'-6" TOP150 1'-0" 1'-0" 2'-0" 3'-0" 4'-6" 5'-6" 8'-6" 1'-0" 2'-0" 3'-6" 5'-0" 7'-6" 8'-0" 9'-0" TRU5 J0151T RIM NAILS AT 6" ON- CENTER. WHEN : REINFORCEMENT TO JOIST WEB 12" LENGTH OF 5/4" - „ ,- „ _ „ - „ ,- „ ,- „ - „ REINFORCING BOTH SIDES, FLANGE WITH 3 ROWS IOD (3") COMMON 250 1 0 1 s 2'-6" 4'-0' S 6 6'-6' 9 0 1 0 2'.0" 4'.0' S s 8'-0' s s 9'-6" BOARD : „ REINFORCEMENT 11T/" 350 V-6" 2'-6" 3'-6" 5'-0" 6'-6" 7'-s" 9'-6" 1'-6" 3'-0" 4'-6" 6'-0" 8'-6" 9'-0" 9'-6" STAGGER NAILS TO AVOID HANGER FACE : NAILS AT 6 ON-CENTER, ON ONE 51DE AT CLOSUREMOUNT 550 V-6" 2'-6" 4'-0" 5'-0" T-O" 8'-0" 10'-6" 3'-6" 5'-0" 6'-0" T-6" 9'-6" 9'-6" 10'-6" SPLITTING. CLINCHED. USE 2 ROWS WITH q�'2 El, BOTH SIDES HANGER AND IlYe8" TJIm JOISTS. AT E5 100C 1'-0" 1'-6" 2'-0" 2'-6" 3'-0" 4'-0" 6'-6" l'-O" 2'-0" 2'-6" T-6" 5'4" 5'-6" 7'-0" FACE GRAIN 300C 1'-6" 2'-0" 3'-0" 3'-6" 4'-6" 5'-6" 9'-0" 1'-6" 2'-6" 3'-6" 4'-6" 7'-0" T-6" 9'-0"SEE CURRENT TRU5 JOIST 400C V-O" 2'-0" T-O" 4'-0" 5'-6" 6'-6" 9'-6" 3'-0" 4'-0" 5'-0" 6'-6" 9'-0" 9'4" 10'-0" HORIZONTAL �`P LITERATURE FOR FRAMING 5" MAXIMUM 130 1'-0" 1'-0" 1'-6" 2'-0" T-O" 3'-6" 5'-0" 5'-6" 8'-6" 1'-0" 2'-0" T-O" 4'-O" 6'-0" T-6" 10'-0" 10'-0" 11'-6" 2 CONNECTORS \ 5" MAXIMUM 250 V-0" T-O" 1'-0" T-O" 3'-0" 4'-0" 6'-6" 7'-0" 10'-0" l'-O" 1'-0" 2'-0" 4'-6" T-O" 8'-6" 10'-6" 101-6" 12'-0" / 350 V-0" 1'-0" T-O" 2'-6" 4'-0" 5'-0" 7'-6" 8'-0" 11'-0" 1'-0" 1 7''-0" 3'.0" 5'-0" -6" 9'-0" 10'-6" 11'-0" 12'-0" E4 NOT FOR USE WITH 3 " TJI J015T E5 E6 1' 14" 550 -0" 1'-0" 2'-0" T-T 5'-6" 6'-6" 8'-6" 9'-0" 12'-0" 2'-6" 4'-0" 5'-6" 7'-0" 9'-0" 10'-0" 12'-0" 12'-0" 13'-0" FLANGE WIDTHS E7 E8 100C 114" 1"0" 1'-0" l'-O" 2'.0" 2'-6" 3'-6" 4'-0" T-O" 1'-0" 1'-0" 2'-0" T-0" 4'-0" 6-0" 7'.0" T-6" 9'4" 300C 1'-0" 1'-0" 1'-6" 2'-6" 3'-6" 4'-0" 5'-6" 6-0" 10'-0" 1'-0" l'-6" T-O" 4'-0" 5'-6" 7'-0" 9'-6" 10'-0" 11'-6" 400C 1'-0" 1'-0" 1'-6" 3'-0" 4'-6" 5'-0" T-O" 8'-0" 11'-0" 2'-0" 3'-6" 4'-6" 6-0" 8'-O" 9'-6" 11'-0" 11'-0" 12'-0" 130 1'-0" 1'-0" 1'-0" 1'-0" 1'-6" 2'-6" T-6" 4'-0" 6-6" T-6" 1'-0" l'-O" 2'-6" 3'-6" 5'-0" 6'-0" 10'-6" 10'-6" 12'-0" 13'-0" NAIL THROUGH 2X_, WOOD WEB STIFFENERS FILLER BLOCK: NAIL WITH FLUSH BEARING PLATE BEARING AT WALL_ BEARING FOR DOOR EXTERIOR DECK ATTACHMENT 250 l'-O" T-O" 1'-0" 1'-0" T-O" 1'-0" T-6" 4'-0" 7'-0" 9'-6" 1'4" 1'-0" 1'-0" 2'4" 5'.0" T-O" 1T-O" 11'-0" 12'-0" 13'-6" BACKER AND REQUIRED IF 51DE5 TEN IOD (39 BOX NAILS, REQUIRED. MAXIMUM Y4" „ „ „ „ „ „ „ „ „ „ „ , „ O R WINDOW N D O W HEADER 350 1-O' 1-0" 1-0 1-0 1-0 2-6 5'-0" 5-s' 8-6 10-6 1-0 1-0 1-0" 3-6 6-0 7-s 11-6 11-6 12-6' 13-6 TJI JOIST WEB WIITH 2 ROWS IOD OF HANGER DO CLINCHED. USE TEN 16D (3 OVERHANG PERMITTED STRUCTURAL EXTERIOR „ „ „ „ „ , „ TRU5 JOIST RIM BOARD) 161, 550 1-0' 1-0" 1-0 1-6' 3'-6' 4-6' 7-0" 7-6' 10'-O' 12-0" 1-0' 2'-6 4'-6" 6-0' 8-s 9-6 13-0 13-0' 14-0' 15-0 (3") COMN�ION NAILS AT b" NOT LATERALLY Y2") BOX NAILS FROM AT BEAM. SHEATHING „ „ „ „ „ BLOCKING PANEL OR BLOCKING FOR 1 OOC 1-0 1-O" 1-0 1-0 1-0' 1-0" 2'-6" 2-6' 4-0 5'-6' 1-0 1-0' 1-0 2'-0" 3-6 4-6' 7-0' T-6 9'-0 10-6 ON-CENTEFa, CLINCHED. USE SUPPORT AT LEAST EACH 51DE WITH 3Y2 STRAP PER GORE IF TOP 3000 1'-0" 1'-0" 1'-0" 1'-0" 2'-0" 2'-s" 4'-0" 4'-6" 6'-6' 8'-6" 1'-0" T-0" 2'-0" T-0" 5'-0" 6'-D" 9'-6" 10'-0" 12'-0" 13'-0" I6D 0)'2") NAILS WITH 516" OF TJI J015T TJIo J015T FLANGE LATERAL SUPPORT PLATE 15 NOT CONTINUOUS 2" MINIMUM 400C 1'-0" 1'-0" 1'-0" 1'-0" 2'-6" 3'-6" 5'-6" 6'-0" 8'-6" 11'-0" 1'-0" 2'-0" 3'-6" 5'-0" 7'-0" 8'-6" 12'-- ' 12'-6" 13'-0" 3Y2" TJIo JOIST TOP FLANGE WIDTH5. USE FIFTEEN BACKER BLOCK: INSTALL OVER HEADER IFLANGE WIDTH5. NAILS WITH TJIo JOIST TIGHT TO TOP FLANGE 2" a" s" 8" 10" 12" 1a%" 1s%4" 2" a" s" s" 10" 12" 143/4' 1s%" DEPTHS GREATER THAN (TI(5HT TO BOTTOM FLANGE ' „ ' - „ „ , „ , , r. 350 1-0 1-O' 1-0' 1-01 4-0' 7;6;' 13�0 1�0' 1�0 3-0 8�0' 13�O 1 15�0 17�6; I6". WITH FACE MOUNT 2" MINIMUM 650 1'-0" T-O" T-O' T-6 6 6' 10 0 15 0 1 0 2 0 6'-6" 10 6 14 6 16 0 18 0 HANGER5). ATTACH WITH %� 1s" , • ,•��••,�" � •' FLASHING ., 3ooc 1'-0' 1'-0" 1-0' 2'-0" 4'-0" 6'-0" 11-0" 1-0" 1'-O' 3-0" 6'-6' 10'-6' 13-0' 16'-6' TOP FLANGE TEN IOD (3") BOX NAILS, 400C 1'-0" 1'-0" 1'-0" 2'-6" 5'-6" 8'-0" 13'-6" 1'-0" 2'-0" 5'-6" 9'-0" 13'-6" 15'-0" 17'-0" HANGER CLINCHED WHEN POSSIBLE. i 350 1'-0" T-0" 1'-0" 1'-0" 2'-6" 6'-0" 10'-0" 14'-6" T-0" 1'-0" 1'-0" 6'-0" 11'-6" TREATED " 20'. 550 1'-0" 1'-0" 1'.0" 1'-0" 3'-6" T-O" 12'-0" 16'-0" 1'-0" 1'-0" 4'-0" 9'-0" 14'-0' WOOD p,`'� FACE MOUNT 2X_ LEDGER Y2" 300C 1-0' 1-O' 1-0 1-0 3-O" 5'-0" 8'-0" 12'-0" 1-0 1-0 BACKER �p,�� Pp5 HANGER DIAMETER g 400c 1'-0° 1'-0° TF Tn,' 3'-0^ s'-o" 10'-0^ 14'-6" 1' \,O) BACKER BLOCK COLUMN LAG BOLT J015T RIM • Leave Ys"web at to and bottom of hole. DO NOT cut oast flanges. �-(') BOTH SIDES OF BOARD p j 9 HANGER HEIGHT MUST BE A WEB WITH SINGLE • Table is based on uniform load tables in current design literature. TJIo JOISTS AND 515 LBS (LSD) PERY2" DIAMETER a For simple span (5 foot minimum) uniformly loaded joists not requiring commercial concentrated loads, one maximum size round hole may be MINIMUM OF 60 � OF J015T DEPTH �2 H3 L L2 ALLOWABLE LOAD 15 525 LE55 (A5D) L�t LAG BOLT located at the center of the joist span provided no other holes occur in the joist. ALLOWABLE HOLES - Beams and Leaders HOLDOM SEE PLAN HOLDOWK SEE PLAN 2-I6d NAILS 0 16.01G 2X DIAMETER OF THE LARGEST HOLE (MINIMUM) FOR LOGATONS FOR LOGATONS HOLDOHN,SEE PLAN 2-I6d NAILS a 16"0/G oz. 8d 0 3'oz. FOR LOCATIONS V DEPTH I 2-16d NAILS 0 EACH STUD 1/2'SHEATHING W/ I FLOOR SHEATHIN6 I/2'SHEATHING W/ 8d a 3' �3 8 NAILS 0 6'0/0 a E76ES ; PER PLAN 8 NAILS 0 6"O/G 0 ED6E5 FLOOR 5HEA7HIN6 O Q ALLOWED HOLE Z 1/2"SHEATHING PV , +12"O/C,a INTERIOR STUDS I FLOOR JOISTS +12'O/G 0 INTERIOR STUDS p 8D NAILS 0 6'O/C`0 ED6E5 I I PER PLAN O O +12'O/C 0 INTERIOR 5MJ5 j '• ' 60 NAILS 0 6'o/G INTO WALL I PER PLAN SD NAILS 0 6'O/G INTO WALL 0 DEPTH 0 0 PLATE,PROVIDE STRAP TIES,IF i I I I I i PLATE,PROVIDE STRAP TIES IF 5!b"m ANCHOR BOLTS PLYWOOD NOT GONTINUOUr 1?Y 8D NAILS 0 4'O/G I r:.a: 0 6'O/G MIN PAST PLATES i 11 PLYWOOD NOT CONTINUOUS 12" 4L Y3 SPAN ALLOWED HOLE ZONE 5PAN : }'.: MIN PAST PLATES N. SIMPSON LSTA16 STRAP REGUARED „ = k• ,!';i'• � I, SIMPSON LSTAI STRAP REGAIIRED '' `k" �t'•` °4€"`" I '" a IF PLYWOOD NOT GONTINIJOW5 1 YWOOD NOT GONT1Nu0U5 CUT ONLYROUND CONCRETE STEM WALL- PAST WALL PLATE a PAST WALL PLATE < HOLES AND ONLYIN I� I '°1t'a' ''++i;'� PY�, ,,�:e''' ''Iu,�'�� Iyw"??P"• U... 2x OR 6NI BLOGKIN6 0 r" ! 7 i ,.Is I•` -", 'r'' �� DOUBLE T NV BEARING PL DOUBLE Nn rV BEMNG P- �' 52•oz.0 END BAY ONLY DOUBLE NUT Wr BEARING PL 51MP50N A55(OR LTP4 ROUND HOLE CHART THE CENTER OF NU WASHER 0 HOLDOVWS WASHER O HOEDOWNS WASHER 0 HOLDOWNS � BEAM DEPTH BEAM M ON +OR FRAMING FOR UNIFORMLY LOADED BEAMS ONLY.. �. coNGRETE HALL SIMPSON ANCHOR a 52"O/G CONCRETE WALL ANCHOR PER o 24'O/C, HOLE SIZE >. ' TH MAXIMUM ROUND (OR LTP4 ON oUT51 • 7ii I o �� ,i"6� r.�_" - I't :1':='. �+'• ��, "" �✓• -,'�;� 5/8'41 ANCHOR BOLTS 3 " n 6'O/G 5/8"o ANCHOR DOLTS •6'o/G 4/s � • RECTANGULAR HOLES ARE NOT ALLOWIED. '-•. EXTERIOR &ARA6E HALL EXTERIOR FOUNDATION HALL EXTERIOR FOUNDATION HALL I 7Ya"to 20" 2" • HOLES IN CANTILEVERS REQUIRE ADD1710NAL ANALYSIS.CID I I;; "I ;l I ,'� ''ti"'' See illustration for Allowed Hole Zone I +' ' ,r�§ f ;� CONCRETE 5L B) (PARALLEIL TO JO 15T5) (PERREND I GULAR TO JO 15TV EXTERIOR SHEAR WALL EXTERIOR SHEAR K^ ALL EXTERIOR SHEAR WALL NAILING REQUIREMENTS HORIZ WIND LOAD CAPACITY = 336 PLF HORIZ WIND LOAD G:APAGITY = 336 PLF HORIZ WIND LOAD CAPACITY = 336 PLF TJI®JOISTS AT BEARINGS: TWO SD ( ") BOX NAILS (I EACH 51DE),511_1 '" 4 • �9 .,, Nl�, 4_,•f,,:,:.- MINIMUM FROM END. �,�,?}.y��t*"✓" 1 .'/ ``�• i .t I r ,`'may '.� �"' .d� �, BLOCKING PANELS,RIM JOIST OR RIM BOARD TO BEARING PLATE: ;lSu �';ry5• TJI® BLOCKING PANELS OR RIM JOIST: 100 09 BOX NAILS AT 6" O.C. 21vD 51JOM155/0N RFl/l55 '•'' I TRUS JOIST RIM BOARD: TOENAIL WITH IOD (3OX NAILS AT b" O.G. OR l BREFZEWi4 Y 8 X lO l2�12�06 ") B ' _ 'L I6D (3Y2") BOX NAILS AT 12" O.G. •} SHEAR TRANSFER: CONNECTIONS EQUIVALENT TO DECKING NAIL Ibd PER SHEARYIHLL MANIC REVEM DATE '^• ;..,. SCHEDULE FLLOOR SHEATHING SCHEDULE. Kw° PEER PLAN " w ed 0 3'oz. FLOOR SHEATHING Ir 8D NAILS 0 b"oic INTO WALL ad a s•oz. PER PLAN RIM BOARD,Rlh�JOIST OR CLOSURE TO TJI®JOIST: PLATE,PROVIDE STRAP TIES' FLOOR PLAN SHEATHING MIGHAEL T_ LO GAN„ ',Sw, •. ; '•� • _,� PLYWOOD NOT GONTINUOl1' 12•MIN PER PLAN 13/ WIDTH OR LESS: TWO IOD (3") BOX NAILS, ONE EACH AT TOP AND PAST PLATES BOTTOM FLANGE. 27 TORLEN COURT HAUPPAUGE NY 11788 FLLOOR PLAN TJI®/PRO 130,350, 100C&300C RIMJOIST: TWO IbD (3 ) BOX NAILS, ONE 631 9'79-2129 PE'ER PLAN FLOOR JOIST ' PER PLAN EACH AT TOP AND BOTTOM FLANGE. 2 TJI®/PRO'"'550&400C RIM JOIST.' TOENAIL JOIST TO RIM JOIST WITH ONE IOD (3") BOX NAIL EACH SIDE OF J015T TOP FLANGE. 12' ARCHITECT 2x BLOCKING 0 92'oz. 165 NAILS o LO KI INTO 2x OR 6NI BLOCKING 0 2-16D NAILS INTO EACH J015T 6NI BLOCKING ''"'�' •' ''� " END BAY ONLY J0015T OR BLOCKING J015T OR BLOCKING 2X4 MINIMUM SQUASH BLOCKS: TWO 100 3" BOX NAILS, ONE EACH AT PLANNER SIMPSON L5TA30 STRAP REQUIRED IF 52"oz.EACH SIDE OF WALL TOP AND BOTTOM FLANGE. ( ) `' '�' PLYWOOD NOT GONTINVOu5 PAST TOP AND VY25 D'CIYPRH WALLBOAR NZD a I'O/G 1/2"6YP5UM BOARD W/ �,��,1 ., .t�.• 4 � ' � BOTTOM WAU.PLATES SIMPSON A35 FRAMING 5D y 9 ty,�+r'• :,,�. y�•!$i, /•� � `*• a,' tE WALLBOARD NAILS o?'O/G ,AI _„` .M•.• �. n _ ,t � ( ANCHOR PER 0 24'O/G 0 I ED6FS AND INTERIOR STUDS a ED6E5 AND INTERIOR ST11Dr I WARNING .•�` �.,. �;r�6a°'��`''�,• 1:�,Io�� r.I,IS°�'�� �`��:a s'�" � CONDITION 15 SIMILAR TO WHERE WALL JOIST RUNS PERPINDIGULAR TO WALL. "'` + _ 9t ` V> •�'=ry i BLOCKING 15 NOT REQUIRED. INTERIOR PARTITION INTERIOR PARTITION ""?':� •,.Y1b: 4�'.kr ,{4ti.r �.,.�ill';j!y,'. iiiriirim, i,rtt I, ' •� =J• ' l ';�,� � �-eu�7� :�I' ,.,;;, as JOISTS ARE UNSTABLE UNTIL BRACED LATERALLY �.:- KULICK RESIDENCE EXTERIOR HALL AT SECOND FLOOR fFAR� E TO JO 5 S BRACINGINCLUD S: AHA BOULEVARD L � LL L I T ) (PERPEND IOU TO JOISTS) E 1895 MINNEH BLOCK:.!;:;Ib(I fl;ti;i!i!I':I';: - EXTERIOR SHEAR WALL IMITERIOR SHEAR WALL W/ LENNGTH > 5 FEET INTERIOR SHEAR WALL W/ LENNGTH > 5 FEET • HANNGEIRS • R MEBOARD SO UTHOLD NY 11971 } ATHING Ir'I'!'f!'!''" �'I°� HORIZ WIND LOAD CAPACITY - 336 PLF HOORIZ WIND LOAD CAPACITY = 100 PLF HORIZ WIND LOAD CAPACITY = 100 PLF DONOTALLOWWORKERS RIMJOIST DO NOT STACK BUILDING ' � M ,,;i,h�; ;,,;!•,, , STRUT LINES t1� j • .y .,� _1. �'' �y" •��;i:M+ `¢Y- �il�l r�fl,l[i,i.G I'1'i� •i�• •" SF TO WALK ON JOISTS UNTIL MATERIALS ON UNSHEATHED TITLE „1, e, �•, ,;;II;I',,117;p''.I i�l' gpP BRACED. WARNING NOTES: JOISTS. j, , ,, .,, .,,• :.: 71,' ,I,, TRUSS LACK OF PROPER BRACING DURING CONSTRUCTION CAN RESULT IN SERIOUS TJI JOIST DETAILS ACCIDENTS.UNDER NORMAL CONDITIONS IF THE FOLLOWING GUIDELINES ARE OBSERVED,ACCIDENTS WILL BE AVOIDED. "ryt,p.•"�, d'':' 1. INSTALL ALL BLOGKIN6,HANGERS,RIM BOARDS AND RIM JOI5T5 AT TJI+4015T END SUPPORTS. 2. ESTABLISH A PERMANENT DECK(%EATHIN6),NAILED TO THE FIRST 4 FEET OF JOISTS AT THE END OF THE JOB NO. O6:Oct DFiAWNCi NO. BAY OR BRAZED END WALL. 3. SAFETY STRUT LINES OF IX4(MINIMUM)MUST BE NAILED TO A BRACED END WALL OR SHEATHED AREA. DATE I I/0-:1/06 4. DRAWIN05 , 5PEGIFIGATIONS AND OTHER DOGUMENTei PREPARED BY THE ARCHITECTT3 ARE THE INSTRUMENTS OF THE ARCHITECT'S 5ERNVIGE AND SHALL REMAIN THE SHEATHING MJST BE PROPERLY NAILED TO EACH TJI•JOIST BEFORE ADDITIONAL LOADS CM BE PLACEDPROPERTY OF THE ARCHITECT,WHETHER OR NOT THE PROJECT FOR WHICH THEY ARE INTENDED ON THE SYSTEM. CONSTRUCTED OR NOT. THE ARGHITEGT'5 DRANINC-�5, 5PEG D IFIGATION5 AN > ALA ASS NOTED OTHER DOCUMENTS WILL NOT ESE USED ON ANY OTHER PROJECTS FOR ADDITIONS TO S. ENDS OF CANTILEVERS REQUIRE STRUT LINES ON BOTH THE TOP AND BOTTOM FLANGE5. THIS PROJECT AND/OR FOR COMPLETION OF THIS PROJECT BY OTHERS, EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO THE ARCHITECT. . TJI•JOIST FLANGE5 MUST REMAIN STRAIGHT WITHIN A TOLERANCE OF y,"FROM TRUE ALIGNMENT. ® COPYRIGHT 2004 DRAWN By N. MARRAti A B A3 A3 53'-0" O.H. I b'-O" lo'-O° 26'-0" ¢ 6" 61 V. ol b'-2" 13'-8" 6'-2" R-Iq BATT 10" I I 2" Xb" 5TUD5 Ir— I I a 16" O.G. I I I I 1O• I I 5'-5" X 5" P GONG PAD BASE OF STEPS ACQ. AGO. AGQ. AGO. I I 3/4" T aE G SUBFLOOR " " (2) 2" X 10" (2) 2" X 10" :o I ELEV. t0'-0" � (2) 2 X 10 O.O. (2) 2 X 10 Lq ® ® ® o ® • — �� I — J F BEAM -' O ( I 8 I L F3 F5 RIM BOARD O O FLOOD VENT 10" POCKET 10" - F3 F3 14' 4 " x S x x ® p x ® I Q iv ELEV. -I'-4" u' 4 n I Q cv 1'-5" iv x J T-2" , '^ R-Iq GATT '" SQUASH BLOCKS (2) 2" X 6" AGO 51LL5 — 2" X 5" AGO CLEAT r- I o L — n 2" X 5" AGQ CLEAT 1 O NOTE: FOUNDATION FLOOD VENTS A5 PER TJI — — -- FOUNDATION FLOOD VENTS SHALL BE AS MANUFACTURED Y (2) 6 ® SILL SEALER W/ — - - - ® ® ® ® ® ® "SMART VENT" OF OCEAN CITY, NJ, OR AN APPROVED EQUAL. TOP CONT. c TERMITE SHIELD L_ .—L I -1 I ALL FLOOD VENTS SHALL MEET ALL 6OVERNIN5 BODIES ORZAH . 5/5 N ANCHOR BOLT S F3 ® BEAM BEAM FI BEAM REGULATIONS AND REQUIREMENTS. ALL VENT5 SHALL BE a V NUT AND 3 X 3 WASHER I POCKET POCKET POCKET ® 3'-0" O.G. 14-4 I 13'-6" 5TAINLE55 STEEL. SMART VENTS ARE CERTIFIED THAT ONE UNIT m SPACE &RAVE 24" X 24" X 12" GONG. FT&. I I MAY BE USED FOR EACH 200 SQUARE FEET OF ENGL05ED AREA. 4 ELEV. -4'-0" O 0 W/3 1/2" m STEELPIPE COLUMN O `;' 'A 10" POURED CONC. d� n e I I `4 Il' O" 15' S" ° 13'-O" IG�" FOUNDATION WALL 10" n l I I p — UNDER KITCHENCABINETS (V.I.Fi (2) 13/4" X 1117/5" LVL 2 P. GONG. SCREED (� � GOAT ON V.V.B. OVER COMPACTED SOIL d a DAMPROOFIN6 m il , UNDER KIT HEN CABINETS (Y.I.F) ELEV. -6'-4"3 I/2" (2) I T/8" LVL FI 8"X I6 STL. PIPE _ _ _ ' �p FLOOD ¢ I I coLUMN GRAWLSFACE ® - a VENT CORNER HOLD DOWNS � ` ELEV. -T-6" F3FI FI x m I SEE DETAIL 3,SHEET TI I 2" P. CONC. SCREED GOAT I p I I (2) 6 OVER V.V.B. ON 4 FOUNDATION FLOOD VENT I # L COMPACTED 501E UNDER ISLAND (V.I.F) — -0 m � — I — BOTTOM CONT. A (2) 1 514" X II 7/5" LVL — — r Q r x _ F3 56" X 36" X 15" — - — — — n �+ x P. CONG. FTC. ,-1 pop FI W/REBAR I m I in - - I II ,/5" ®I I6" O.G. m I p wr 5 1/5" � I W — STEEL PIPE T.O. SLAB ELEV. —� 8" _4 A5 PER TEST BORING -GROUNDWATER J I TJI 360 J5T5. ® OLD UNDER 15LAND (V.I.FJ x �;' -6-4" (V.I.F) I Q F3 / / - _ _ _ _ (2) 1 3_/4" X I V8 LVL y� I I, 8" 2'-0" X 5'-5>" X 5" I • I ¢ ® FI / FI m I Q " I Q 1 r x w/op FI l0' o 24.8 TYTIGAL 'FOUNDATION P.GONG. PAID S'BASE OF 5TEP5 �y I II '1/8 ® 16 O.G. _ ¢QTJI 360 J5T5. I l l/8" ® I6" O.G. " I I I I DETAIL Q4 I •� (2) 11 5/4" X ° v HEARTH ABOVE 50ALE: 1/2" m L— r TJI 36o JOISTS L u, _ _ _ v II 116 LVL J L — — r — UNDER STAIR WALL (V.I.F) —.� " I® X r p (2) 13/4" X I II'i/5" LVL x Q — in I F3 FJ _ _ — .�� I 1 �-- --� UNEXGAVATED 4'-O" q'-8" m J 4'-6" 4'-0" 4'-6" O o UNEXGAVATED I 4" P.GONG. SLAB Wr n I I A4 n 'y x x cv J BEAM ° OPENING ° BEAM OPENING 6" X 6" 1.4 X 1.4 WWM x IU POCKET POCKET — I 4" P.GONG. SLAB 1AV I ON COMPACTED SOIL y K-I WWM V I I ° I ON COMPACTED SOIL I ( 6" X 6" 1.4 X 1.4 O I II© o — _ — � m a � � ,— - - - - - - - - - - - — — - - - - - - 5" GONG. I 5" X 5" ASH G.O. (2) 13/4" X I I '1/5" LVL ^ (2) 1 3/4" X 11 Ile," LVL CHEEK I 5" X I6" - F3 I I VyALL FOUND. ¢ �_ I I FLOG r- CORNER HOLD DOHN5 VENT 4 5/5" m ANCHOR BOLTS 2" X 8" F.J. i x I dJ SEE DETAIL 3,SHEET TI - TYPICAL 12" LONG of " I I I — — Zi p AGQ 0I6 O.G. I n iv „ " " I6'-10" it m ® I I I in SILL PLATE 2-O x 2-O X 02 1-8 7'-a" is r 6-6" 6-6 W/ 12" X 12" COWL. PIER 5" X I6" = 4 I 1 5/4" HD5A HOLDDO HN 13IC-FOOT FT6. F r VENOR 56" 41 T I I N I — _J MIN. C - - I -1 G I ® I ¢ — A4 --� A4 4 � 3 I - - - - - - - - - - — F3 j — D.O. �� 3 I/2�X II ?/5" LVL j D.O. j D.O. — IFLOOD BOUrID ¢ Q ® O ® DROPPED "�/ DROPPED ® / DROPPED - — — — ____ o — VENT 5" FROST WALL I 3' 4" c — s� FI FI " FI FI I 4'-O" HOLD DOWNS 4" CONG. APRON m g " " 21-10 SEE DETAIL 2,SHEET TI H/BEL&IUM BLOCK ,� I'-Q 3'-0 n in O O 2'40 X 26'-O" TYP. 5/8"� X 12" L o , _ ° P. GONG. STEPS UP 6 R a V/5 T 0 10" N.I.F) Q 4 HP5 A CORNER -� O m I m PREPARE OPENING TO ;n m GRA&SPAGE ® " DOOR MODE ZE B" HOLDDONN F3 ® 2 P. GONG. SCREED GOAT r 1 E- OVER V.V.B. ON 1 = 10' COMPACTED 501E x Z T.O. SLAB ELEV. iA II I II _ = s -6'-4" (V.I.F) I SGAL /2 - -O / 2NO 5415M/55/0N REV15E 12112106 NS ® BREFZEl�r4 Y 8 X l0 CORNER HOLD DOW SEE DETAIL 3,5HEET TI 5" X 16" FOUNDATION MARK FEW" DATE I FLOOD VENTS I M:ICHAEL T_ LOGAN I 27 TIORLEN COURT,HAUPPAUGE, NY 11788 631 979-2129 I I ARCHITECT PLANNER 10'-0" I q'-6" I 10'-0" 5'-8" II" 3'-O" ll" 16-4" 4'-10" 10 M.O. PROJECT KULICK RESIDENCE 1895 MINNEHAHA BOULEVARD 11'-b" 2q'-6" lo'—o" 26'-0" SOIUTHOLD, NY 11971 lo 6" "..� 701LE Ss'-o° O.A. _ . , ` FOIUNDATION PLAN dry. FOOTING SCHEDULE A B FI 24" X 24" X 12" DEEP P.G. FOOTING JOB No. 06:09 DRAW°NO. A3 A3 . F2 56" X 56" X IS" DEEP P.G. FOOTING W/ (4) #4 REBAR5 X 2'-6" @ BOTTOM EA. WAY t '" - X' ' DATE 11121106 DRAHINCG5 , 5PECIFICATION5 AND OTHER DOCUMENTS 'PREPARED BY THE ARCHITECT t ARE THE IN5TRUMENT5 OF THE ARCHITECT'S SERVICE AND 5HALL REMAIN THE ✓I �I 3 CLEAR FROM BOTTOM OF FOOTING. - PROPERTY OF THE ARCHITECT,WHETHER OR NOT THE PROJECT FOR WHICH THEY ARE INTENDEDFOUNDATION FLAN IS CON5TRUCTED OR NOT. THE ARCHITECT'S DR.AbNINGS, Al 5PEGIFIGATIONS AND F5 24" X 24" X 12" DEEP P.G. FOOTING W/ OTHER DOCUMENTS HILL NOT BE USED ON ANY OTHER PROJECT5 FOR ADDITIONS TO �A� 5 OTBO THI5 PROJECT AND/OR FOR COMPLETION OF THIS PROJECT BY OTHERS, EXCEPT BY 50ALE: 1/4" = 1'-0" WIT X 12" P. GONG. PIER AGREEMENT IN WRITING AND WITH APPROPRIATE COMF'EN5ATION TO THE ARCHITECT. O GOP R C HT 2006 DRAWIN BY w MARRA 10'-O" 261-0" lo 13'4" ¢6" 6" i cv COLUMN COL" COLUMN (COLUMN I ( e bN H B 4 6 SAVANNAH 1 T.O. PLATE COLUMN I HANDRAIL SYSTEM �O EL. +V-O" I I VO H B rF 6 I I ® 36" A.F.F. (TYPE I I m MSTEPS Y I AA6 PERMA-CAST 5/6" THREADED ROD ( I e Q STEPS 2'-O" X b'-O" X b" I T.O. PLATE I COLUMN(TYP) I SEE DETAIL I,SHEET TI ¢ 5/4" X 4" T # 6E �^ I P. CONG. PAD (TYPJ I EL. +a-0 I I 5" 4) COLUMN MAHO60NY DEC:KIN6 I I — — T.O. PLATE — — W/HIDDEN FLASHING I — " " " i(L �L + 0" I I 5/a" (P ANCHOR BOLTS (2) 2" X 10" ACG. (2) 2" X 10 AGQ. I (2) 2 X 10 AGG2. G 35 0 MA' ¢ I TYPICAL 12 LONG ,k• I I T T.O. PL +b'-O" :o . (3) 2" X 12" :a 6" (2) 2" X 10" (2)I 2" X 10" 5/4" X 4" T d 6 I m I SILL PLATE p ,II �ixv iI b.-O. ry _ TO PLATE ACO. � MAHOC70NY DEGKIN6 7 E OD /HIDDEN FLASHING I I 13/4" HD5A HOLDD— OWL G.H. v MIN.PORCHPELLA SIGNR SERIES"in 9 4 I �x x SLIDING FRENCH DOORS � th - 3 1/2 X 5 1/4 ELLA1001 14161 O O(4 PANEL) WOOD FLOOR 0 LSE PSL P05T — "I281 XD OAP 4 I ^ 5 1/4" X II '!/b" PAI`LA P5L - 6 5 I/4" X II /b" PARALLAM P5L FLUSH — — (3) 2" X 5 T. b" N I L 15'-0" 4 4- 6 13 O.H. 4" I E P 5 I/4 X 5 I/ 8 SL 5 I/4" X 5 I/4" T.O. PLATE v I I I :o IQ x IbE P5L EL. +I I'_4" 0 \� TYP. 5/b"0 X 12" L cm ( I I I �L+ " O.H. I I <� S x I I II 7/a" F.J. 0 16" O.G. Q TYP. - - _ (3) R.R. vp Q I TJI 360 JOISTS BEDROOM #3 4 I T.O. PLATE �I�w, HP5A ' C,0RNER 5-O" R I = a'-O" G.H. = EL. +b'-ON t I LL 21' PREPARE FOR CARPET x HOLOPONN 1.8E ftL POST(TYP�� F x I I ¢ CONCRETE d + 3 1/2" X 5 1/4" • " BLUE5TONEI STEP5 i Q I.bE P5L F05T UP v 4 +� I I r 4 " KITCHEN II 7/8" F.J. a 16" O.G. m ( 3_8" C C I �J \�, II '�60 TJI 360 5ERIE5 IRSEE DETAHIL03D DOMS 5HEET TI I SGALL. I/211 I I_OII A? I I I I r 2 X 12 GATH. 10'- WOOD FLOORF' -2668 — �, x �� GL6. I G.H 3- BIFOLD DRS. ( T.O.+B'-1 12" AW I AW�51 'v o ¢ a1� s Q � I ry I I Q x n RIDGE FAMILY I 3 I/2' X II /a" P RALLAM PSL 24" I pb� - - 2" X 4 w o o �, ZOOM I - OS. p n z / GATH.GL6. UNDERL WOOD _b. (2) 2" X 8" (2) 2" X 8" I'-4„ �.�' \0 5 I/4" I/4" I I Q in I 25'-4" O.H. WOOD FLOOR I.bE P5L I VE6. O SADDLE LA - - ( ( /`�1 ^ II P05T VU SINK 36" 00 0 4" 3�_8" 4 _ 4 n a X a COL. 15LAND 3'- (� (3) 2" X 4" P05T p EL.: LAB 4" SLOPED GL6. ENCLOSURE I O Q / / WRAP POST I 26 a x z (3) 2 p �L1 —W/TRfM T6-- ¢ N • w POST I \ PL / � p � 24 24 b'-O' 0 I cv _ (3) R.R. KITCHEN UNDER RIDGE TO G.H. \ NOTES HIP CORNER 3 I/2" X � ( T.O. FOUND. WAL\ '3'' p ry / E . +bl-f 1/2 - BELLAWOOD HARDWOOD FLOORS I b t10' G.H. II 1/a" PARALLAM WOOD " -f- \, 6-0" P5L i ° } IN FAMILY ROOM, KITCHEN AND 2'-0" X q'-6" X b" I r 56"WIDE m WOOD I . FLOORING 0 EL.: -0-4 ti �� x ,y \Q BACK HALL. P.GONG. PAD (TY�'J 5 1/4" X 5 1/4" 56" HIGH HANDRAIL I 0 H 5 d 6 /�\ ry /� I Q Q 4 I.bE P5L POST _ _ _ __ Q G. ILE 4 iv - TILE IN BATHS AND LAUNDRY ROOM. m ry (V.LF) ® EA. END F�'OPENIN -- - :r HANDRAIL iv 2" X 10" R. . ® 16" O.G. in ,n tt _ - _ I o d 48,XI2 PANTRY yt x ® 3 A.F.F. ui - CARPET ALL BEDROOMS CAMEROOM �� N FLUSH T.O. PLATE T.O. PLATE � I I — — N 2-GAR GARAGE EL. PLAT EL. +II'-4" ON X q6" FLUSH s� Q -" — 2' X 10 R.R. ® Ib O.G. STUDY AND UPSTAIRS HALL. I Im WOOD (2) 266'a 5L.DR T.O. STONE (3) 2" X 12' L " �? - INSULATE ALL BATH AND LAUNDRY - Iq_p - EL.: -O-2 2 X 12 RIDGE O Q D WALLS WITH SOUND DEADENING BLANKETS. p I I 4 FLOORING G. TILE - GOV" LEAVE OPEN Ia C.H. I '� P N Y UP III` OYER _� I 6" X b" +;X� n n -GEILIN6 FANS IN ALL MAIN ROOMS - I " 4" P. GONG. SLAB W/ " X 6" Al AND BEDROOMS. O �iY O AREA FOR 12 in „ m m I m 7 NEWEL P05T PROW E HOLD DOWN 1.4 X 1.4 W.W.M. ON V.V.B: ' I PO I I DESK UNIT BY I I&R 8 O G.H. 9 (•YF) � I ALL FRONT WINDOWS AND SLIDERS x n 7.5" v 6 STRAP NG FOR OIL TANK / OVER COMPACTED SOIL\ v �- .": � OTHERS " " 'o " ) " " °s� TO HAVE INTEGRAL BLINDS. iv 5/4"�)<4" T d 6 � (3) 2 X a I (2) 13/4 X I I "1 a 2 X a' � _ � GONNEG N TO SLAB MAH060NY ; : -- _ _ - - - T - " 5/b" "TYPE X" FIRE CODE O p 3 cq i -n Dbl129E1 `U- 4" 11 4" 4" „ Q RIDGE / GYP. BD. ON WALLS \ti x 4" FIRE I UPPER GAB. 4 �yP 68 6 OIL I 'L \rye d CEILIN65 _ _ _ FASTENERS BRICK q''a 5'-b" LOWER GAB. 3'-g" -0" 6'-10" x Ln TANK OVER ¢ COVE D �/ �y+ ° )i \ Q 6" SOLID DOUR E ROD d SHELF �� C.H." BREEZE ry'X_ /� " " \ - - r BLONCK 5 I/4" X 51/4" PULL-DOWN b�' n p O. ROOM p m (3) 2 X 4 POST \ LINE OF I m I bE P5L W. 1. CLOSET I _ BALCONY POST CU �? G.H. + -� HOLD DOWN5 EVE I `gyp q'_ON O _O" H.W. G. TILE (5) 2" X 12" SEE DETAIL 2,5HEET TI O I �K� iA �v I v G.H. I G. TILE 61' H. HTR. -p,� URN. — / X B' Av D. r MASTER AUNDRY wD. SADDLE ry: ; �'9�p°4- OO..H.. I x O FLOOR �, 4 U I6'-O" X 7'-O" COMPOSITE O.H.GARAGE DOOR A _ BEDROOM o W � °' TRADITIONAL STYLE W/WINDOWS \6 G 1 C Q DRAIN STACK 8 0 n ,n q'-0" G.H. ® - - 1 a-O' r W/D 5/5 5/b" „TYPE X" ''�: > t-� b 14" PL. 6L. MIRROR o FIRE GOD1E (2) 2" X a' G.H. z Q PREPARE FOR CARPET tL 0 12 X 12 GYP. BD. SON (2) 13/4" X 14" LVL co SAVANNAH I m - - — - 71LE WALLS d CLCS. Q HANDRAIL I 5 1/4" X 5 I/4" '_ TOWEL MED. MED. 2 X 4a 1 I/4" P. GOING. - -; SYSTEM I Q I 0121110.G. LbE P5L POST - ~ GAB. GAB. 5HWR iv X 2'-0" X 26'-O" X 4" POURED GONG. APRON O ® EA. END �0 4" 4" CERAMIC. VILE (TYPa m v W/BEL6IUM BLOCK PAVERS ii- PREPARE FiOR tESTONE GRETE 414 ,.- _ x " J 4 6 I I-4 - _ tom- CARPET. 5 FS - a- CORNER HOLD DOWNS 14 t (`+ i SEE DETAIL 3,SHEET TI " BEDROOM #2 n • G.H. ? ' IT-2 i I I 1 ti q-O G.H. `� I '^ 6" (5) 2" x 6" (3) 2" X 6" _ MASTER 1LCo 4 t' - - • — — _...............:_.....,...:... .... . . = TILE _ o _ :;. ... .._. . .. ,,,,..m....,. „- :,w ...,.:. = OR5 DRIVEWAY s 4N r m BATH = ' " (2) " X 10" A 3'-0N = q 4" 2�_ I cv c_v 13'-2" :'i' MO B /� m PBERMA GA5T AW I251 AW I251 x \ - „ n COLUMNS � I ZND SIJBM/55/ON REMISE 12112106 - x E-STANDIN , �• n o o G I o BRFEZEGIli4 Y 8 X lO 4Ln CORNER HOLD DOWNS (3) a" X b" m I mw �� DATE �+ SEE DETAIL 3,SHEET TI \ :::..:... ..:..:::.:...:..n.::,.v:.:.. 1 AH A I ��o B ()2AN 251" T.O. PL. 251 I MICHAEL T_ LOGAN P EL. +q-0 I CORNER HOLD DOWN5 27 TORLEN COURT, HAUPPAUGE,NY 11788 \ PQ� SEE DETAIL 3,SHEET TI I 631 979-2129 b" Uti I I 4'-b" 4'-0" 10'-0" 3'-6" a'-O" I'I'-6" 4'-O" 6'-O" 4'-0" 2'-6" 2'-6" I6'-0" V-O" ARCHITECT PLANNER 10'-0" 26'-0" O.H. �y TYR �c PROJECT KIULICK RESIDENCE 18t95 MINNEHAHA BOULEVARD SOUTHOLD, NY 11971 �I � FIRST FLOOR PLAT � LEND FELLA DESIGNER SERIES(WHITE): FRENCH 5LIDER5,GA5EMENT,*ANINGS �E - W/ INTEGRAL BLINDS TO BE SELECTED BY OWNER ' ' `tlr., FIRST FLOOR PLAN 5GALE" 1/4° = 11-011 - DIVIDED LITE GRILLE - 3/4" BETWEEN THE GLASS WOOD/GL.AD 6RILLE5 - INSULATED HURRICANE 5HIELD-IMPACT RESISTANT CLASS ! %- `' •^" NEW 4" INT. WALL CONSTRUCTION00 %7 ,; ,• LIVING 5FAGE: 2125 5.F. - ' BREEZEWAY: J S.F.C� �� NEW 6" EXT. WALL CONSTRUCTION Joy NO. 06:09 °� °NO. GARAGE: 540 S.F. p�7P�-7 NEW INTERIOR BEARING WALL GON5TRUCTION F F-I �---- ._— DkTE 11121106 DRAWING5 ,SPECIFICATIONS AND OTHER DOCUMEPNTS PREPARED FY THE ARCHITECT BRICK VENEER ARE THE IN5TRUMENTS OF THE ARCHITECT'S SEERVICE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT,I^IHETHER OR NOT THE PROOJECT FOR WHICH THEY ARE INTENDED A 2 15 CON D 5TRUOTED OR NOT. THE ARCHITECT'5 PRAWIN05, SPECIFICATION5 AND SCALEO D OTHER DOCUMENT5 WILL NOT BE U5ED ON ANY OTWER PROJECTS FOR ADDITION5 TO TH15 PROJECT AND/OR FOR COMPLETION OF THIS, PROJECT BY OTHERS, EXCEPT DY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO THE ARCHITECT. GO R G T 2006 oewvurt J31f !N. Mr4Rlv4 ol 4" VTR ROOF 4" VTR 2 1/211 BATH #5 LAV 1 I I/2° 411 411 TUB 11/2° 2ND FLR 211 311 co I A B 3" LAUNDRY KITCHEN i 1/2° BATH #2 A3 A3 MA5TER BATH 2 I/2" _ -- —I� 1 1/2" — — — — T.O. PLATE -` ` � 11 � � f 111 ~ ~ � 1 „ ` b" ALUM GUTTER/LEADER EL. +8-0" I I/21, 1 1 1 1/2 1 '1/2 _ �— r .� — I it „ " 1r J^ 11 1 I/2 11 I LAV i " 11 r — 1 2 1/2" 1 LAV I 4 SINK I I I/2 NK i I I/2 I SINK I 4 i ( I I/2 1 2 1/2 I 54N R MACH I DW SHO( R W.G. � 1 1/2 � 15T FLR 211 211 511 1 1/2.1 1 1/21, 1 1/2° LE 1, O.H. \` 2,1 GO GO ---___._- 2 I I/2'" 2" 3 11 3 GO .�I \ X T.O. PLATE / I'-4" " 11 3 \ POST UP T.O.PLATE 0 I O EL. +11-4" I O.H. ' HOUSE 4" 4." CIO \ EL. +11-4 iv ® Z / (NP) TIE INTO EXISTING APPROVED GO TRAPS co CO „ 4" E.H.G.I. SUFFOLK CO. SANITARY SYSTEM 4„ 4 GO o RAKE cv O.H. � 2-0" \\ 12" 0•G• �I Il 6" 0•G• ry r o I I x / POST UP -- -v in I �j u� / T.O. PLATE EL. +B'-O" FLUM51 NO RISER ED I AORAM PELILA ARGHTOP I I \ - " 50 YR. ARCHITECTURAL / I NOT TO 5GALE '1012 (3\ ) 2" X 12'. R`x ( I U •ASPHALT ROOF SHINGLE o I I _ ;........_ . ...... ICE b WATER SHIELD \ ;y tL ALL HIPS,RIDGES, I I OST UP r �� 3 EAVES,VERTICAL WALL ' +�e, x TO ROOF C ONSTR. T.O. PLATE � �- X `1®I "�C \� �y�p` � I I ry sk30 BLDG. FELT P Q� � EL. 8 I I/2 O� x •SHEA p HGLYWOOD �' / I 3 i/2" X 5 1/4" D Q I iv �� \ � I ( it +QP I I.SE PSL POST 6" ALUM 6UTTER/LEADER X � RIDGE VENT— I \ O b'-O" HIGH +�b NAL2" X 12" RIDGE \ I I 2 X 4" ® I6I O.G. �� / I 2" X 12" ROOF RAFTERS 0 16" O.G. I I I n J-1 II n J ' D. FIR -- — I 277, � Q x eY \ 5 1/21, X 5 1/4" I 0 LSE P5L POST 0 ATTIC I-- Z50 YR. ARCH. � r� J t- I I ROOF SHINGLE d / (5) 2" X 12" R.R. P UP 5 I/4" X 5 I/4" / v /7 I UP LSE P5L POST , n p ATTIC I T.O. PLATE --_ - +" J EXHAUST FAN n' EL. +e,'-I 1/2" w 2" X 12" R.R.0 12" O.G. Iq'-O" ABOVE LL I G.H. I o g I D. FIR I,'-10" \ / 29"-2" I I �,, '� O �Q 1'-O" 4'-0" 6'-6" ILL 4 3-2" x „ 12" R..R. ® 12" O.G. o� � — — I ? ry+ I 2" X 10" � I ROOF RAFTERS® I6 O.G. x CHIMNEY Q D. FIR 12" XI6" �+ T.O. PLATE 4" BRICK VENEER T.G. FLUE 2" 8' J. ® I6" O. ATTIC }-�Q: O �? D. FIR I I x O RIDGE VENT EL. +II-4" POST a iv DN O T ACCESS '1' F o L�l 2" X 10" ROOF RAFTERS ® I6" O.G. I D OVERLAY _ 1/2 WALL ® I �`fl I m 16 R �� �-t ® O AY <<+�, 2X 12" RIDGE D. FIR+42 A.F.F. iv RAILS ® 15" v � xRIDGEO F- - - _ I ° � 2 2" X12' , ❑ ® 56 A.F.F. �J � ROOF Jp�%' A +- O T.O. PLATE p i/2 WALL �6e v I \ry ® y OVABLE Q +9'-O A.F.F. :fl O ?, �} „ " �j m in x IL O ry P �ry _ DREGK W/ ® a ��P+�.�n ® 1 M5��1 / I �� J ')--} LL u- Q 5/4" X 4" �'I� `r 'v ® u - p u +may ;q I MAHOGANY �j Vie- — 1- �- � �� QI � Q I I DECKING H B d G POVER SINGLE I � � �#' II'-O" 'LY x -O" � SAVANNAH I MEMBRANE cv - (� 0 9'-b" x �0 O HANDLLS SYSTRAIL ROOFING q I G.H. G.H. N 56" A.F.F. rz I �n- X x- Q CAME 26'-6" 1 O. BTHRM. #3 TUB -,�D 7- THe - 5H R A4 ¢ in •�' = r O Q ROOM 2" X 12" RIDGE WG 6LA5 ' 2" X 10" R.R. ® II6" O.G. _ to 4" V - N I O ENGL SURE — NEWEL „ 4" z v OATH. GL6. POST UP p)I " ' y� , D. FIR " POST 5-2 S x ® ® 11'-0" A.F.F. q-O G.H. UNFINISHED 'D r ZD - X = - `fl X .0 n I SEE DETAIL I cv tt( 2" X 12 rOi n 3 cv „ SHEET A4 i MED.GAB. STO � 6 ALUM 6UTTER/LEADER :p " e " " °- 4) ' P05 UP RIDGE Ln P_.—ITCH Jh 5 1/2 X 5 1/2 „ 5 1/2 X 5 1/2 I �' + 2_0„ 3-6" 31-0" 3 O" \ q'-O" G.H. I , �r r +. ROOFING-�►' I.SE P5L P05T O I.SE P5L P05T m -� r 1 m (TYP) x ON EA. 51DE I ltilryv�i 4` 4" 13/4" T d 6 SUBFLOOR 4 20'-4" I / 12'-2" ! 2" X 8" G.J. iY (3) 2" X 6" (3) 2" X 6" 6 R.R. ��Q 4 cv y/ " 'c:;, ws:• ` ., " " ° :.: :.-r:..:::.:::::: `::rii�:':.':i: 'i i:•:: '_..................:•. / t v _ 6 I'-4" AN 251 AN 251 0 ® t ��� , O.H. -�-\, 3; a ' p x ry��Q- STUDY +�`°�. - - - - - - - - - - - 4 x o o 2ND 511JBM15310N REVISE' 12112106 I/2 WALL ® I I m/ n P I BREFZFGY�4 Y 8 X lO +42" A.F.F. CONT. (3) 2" X 12" w (3) 2" X 6" 1 „ ..:..:':.;'::::::ev::•::::•:::::::.:,::.::;.,,":•:::•: .:...-:.:::.:::.::.:::.::::::::^::::::.-::::::.r:rr::......:::::::.-:':....... � :::.':.......:::.:,•.:':.-:;':.':.:;':..:.:::......_.;........................... ..::.;... MARK O.H. .:...:.::.:.:.:.. :.::.::.:.:::::.-: ::,..:.::._:.:_:.:.:...,_:..........._....,.......,......................_:.... ......:........._..:..:...............:......._...................._....:.....:............ FiEV1810N DATE 251 ;� \ LINE of ROOF ABOVE — MICHAEL T- LOGAN Q , I 2.7 TORLEN COURT,HAUPPAUGE,NY 11788 4'-0" 10'-0" 5'-6" 8'-0" 11'-6" 4'-0" 631 979-2129 ARCHITECT PLANNER 4?'-0" BALCONY Ir PFKXE--CT KULICK RESIDENCE A3 LEGEND 1895 MINNEHAHA BOULEVARD SOUTHOLD, NY 11971 NEW 4" INT. WALL CONSTRUCTION TnLE SECOND FLOOR PLAN NEW 6" EXT. WALL CONSTRUCTION 5EC./ONP FLOOR PLAN, 12-7 70#F-3 NEW INTERIOR BEARING WALL CONSTRUCTION SCALE: I/4" = I'-O' BRICK VENEER .JOB NO. O6"Oq DRAWM NO. 4 DATE 11121106 DRAWING5 , 5FEGIFIGATION5 AND OTHER DOGU"ENTS PREPARED BY THE ARCHITECT LIVING 5PAGE: 568 5.F. ARE THE IN5TRUMENTS OF= THE ARCHITEGT'5 SERVICE AND SHALL REMAIN THE A3 PROPERTY OF THE ARGHITI=GT,WHETHER OR NOT THE PROJECT FOR WHICH THEY ARE INTENDED SALE �,� NOD 15 GON5TRUGTED OR NOT. THE ARGHITECT'5 DRAWIN65, SPECIFICATIONS AND STORAGE 5PAGE: 26q 5.F. OTHER DOCUMENTS WILL NOT BE USED ON ANY OTHER PROJECTS FOR ADDITIONS TO I PROJECT AND/OR FOR COMPLETION OF THIS PROJECT BY OTHERS,EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPEN5ATION TO THE ARCHITECT. © CoF`llrRl0HT 2006 aFwwN By H N1�4R124 T.G. FLUE CEMENT MASH CONT. RIDGE VENT BRICK GAP BRICK CHIMNEY GERTAINTEED CEDAR IMPRESSIONS VINYL 5HINGLE5 AZEK KEYSTONE 5/4" X 6" AZEK TOP GAP 1/2 WALL ® 42" A.F.F. 12 6-O„ FELLA GLAD SUNBURST FULL ARCH HEAD 1012 -_ _._ASPHALT 12. CRICKET___.._._._ T.O. PL. 2ND FLOOR: +Iq'-O" — _. 1 AZEK TRIM _ Q _ 50 YR. ARCHITECTURAL ROOF 5HINGLE5 .----- - , . '-.` ° 5/4" X 6" FREIZE BD. COPPER 5 - — _—_FLA5HIN6 0.H. I L -O" ND FLR. PL.ELEV.: +Iq'-O" — — O.H. 2ND FLR PL. ELEV.; +Iq'-ON '--�- — 2" X 8" ® I6" O.G. (PITCHED) - — 12 DECK W/ SINGLE. PLY EPDM FELLA GLAD SUNBURST— MEMBRANE SURFACE FULL A H HEAD 1012 12 I" X 8" r I" X 2" - - --- y-- CEDAR IMPRESSIONS •-1� —AZEK IM AZEK GAP ® +42" A.F.F. GERTAIN'TEED CEDAR IMFPZ515IONS VINYL - ® I/2" WALL 5HINGLE5® FRONT ELEVATIOMS - -0„ I/2 WALL ® 4:2 H B $ 6 SAVANNAH T.O.FL_* DORMER ELEV. +12'.-5" — — - AT EA. 51DE HANDRAIL SYSTEM H B 4 G SAVANNAH =80_T_0 "WIWW T ® +36" A.F.F. HANDRAIL 5Y5TEM __.E_E.V�+II'=8"—"-==_ _`�-= HIP RETURN 0 FRONT ELEVATION 1^EXTERIOR- A -- -�� ONLY 2ND FLOOR ELEV.: +10'-0" --. HIDDEN FLA5HIN6 m- — 2ND FLOOR ELEV.: +10'-0" I" X 8" AZEK TRIM W/FLASHING - 15T FLR. PL. ELV.: +01 - T.O. FL. 0 PORCH — ELEV. +8,'-0" 5 " VINYL CORNER BD. W/ 114" RND. EDGE (TYP) CEPARTT 8"m H B 4 6 DERMA-CAST IMPRESSION SIDING HIDDEN FLASHING COLUMN / H B $ 6 SAVANNAH HANDRAILL TTT SYSTEM. BALLU5TER5 ® 5" O.G. MAX. I" X 12" AZEK TRIM BD. 5/4" X 4" MAHOGONY DECKING W/ IN X 4" AZEK TRIM IN REMOVABLE 5ECTION5 METAL FLASHING / T.O. 1ST FL. ELEV. +O'-O" _ I5T FLOOR ELEV.: O'-0" 5/4" X 12" AZEK FA501A BD. p — — W/ I" X 4" AZEK TRIM VINYL 51 G 12" x 30" AZEK 2" X 8," AGQ m _ GED MPRE551oN5, METAL ooao0ao0❑aa0o a00a❑ ❑0000000000000a0 o❑0a000oo000000❑ 00000000000000a 0000000000000000 0e130000000o00000 COLUMN ENCLOSURE W/ FLASHING - a a0o00000000❑a ao0000a000a0oo0o0o00a❑ 000000000000o000 000000000000000 0000000000000000 0ooaoa0000aoo0 _' APPLIED MOLDING TRIM (2) 2" X 4" AGQ. PLATE00 ❑000000a00o0❑ 0o0000a0000000a00ao0a0 0000000000❑00000 000000000000000 ❑a❑aa00000000000 ❑ ^^^^^^ �❑❑❑o❑0ao 0000000000000 00000❑00000000000a000❑ o0000000000000a0 00000000000000a ❑0❑❑❑0000000000o aAZEK TRIM❑❑ o :,':;�:-,': .:;;.. ;.-•,:.�.. LINE OF ROOF RAFTERS m PITCH 0000 ❑aa0o0000a000 00000a00aao0❑000000000 0000000000000000 000000000000000 0000000000000000 oa000000a000aa❑ 00 _ ❑0oaoo 0a00000a0000a oaao00000000000o❑00000 aooa00000000 000 000000000000000 ❑0o0o❑ao0o❑a0000❑ 0o0o0a❑0a0o000 ❑00 / o a o 0 0 a o `'' GRADE 2ND FLR. EL.: +10'-0" �❑aoo0oa0 I I STUCCO FINISH (TYP) ON ALL EXPOSED GONG. i — — _ — 15T FLR. PL. EL: +q'-O" — STEPS — �— 2'-O" X 8'-0" X 8�" 2'-0" X q'-6" X 8" 2" X 2" CEDAR LATTICE P.GONG. PAD m P. GONG. PAD® TRUSS JOIST BASE OF STEPS BASE 0. STEPSRIM R ® - Bf:RONT ELEVATION FLOOR TRIM O 2" X 8" a- SCALE: I/4" = I'-O" AGQ CLEAT 5/4" COX PLYWD. 5HEATHIN5 2" X ,5" ACQ �- O CONT. RIDGE VEN4T 2" X 8" F.J. TAPERED 50 YR. ARCHITECTURAL Q z BRICK CHIMNEY BEYOND (2) 2" X 10" HDR. W/ (2) 2" X 4" ROOF 5HINGLE5 n I" X 12" AZEK TRIM o ALL 51DE5 EXPOSED ATTIC EXAUST FAN 2" X 8" AGQ G.J. 0 16" O.G. 8"0 H B $ G PERMA CAST COLUMN 12 VINYL INVI5IVENT BEADED SOFFIT 1 -- ------ — - - 2 X 8 AGQ CLEAT it e- 2ND FLR. PL. ELEV.: +Iq'-O"' _...•, _......_....,.... _._ . .•_...... ...... ..... .............•,.,.,.._. ,: +Iq 'r 2ND FLR FL. ELEV ___. .. BALCONY DETAIL 5/4" X 6" VINYL FREIZE = VINYL CLAPBOARD 51DIN6 — _ ._,._ ._._.._....._... ..-.. . _ ..- - ,- LINE OF BREEZEWAY"'�- __._ ....._..._-._..._,.,.-... _ _„_..,,._. BEYOND .... - ......_...._._. 12 2 Q 2ND FLOOR ELEV.: +10'-0" 1ST Z. FL. ELV.: +q-0 T.b. PL:`®`GARAGE EL: +8 1172 = T.O. PL. ® PORCH EL. +8 OIL / 2ND 5415MI55/0N RFI/155 /2/l2/06 BRFFZFGY�1 Y 8 X /O' 1'-4" O.H. 1'-4" O:H. VINYL SIDING 5" VINYL CORNER BOARD W/ 114" ROUND EDGE LINE OF * " P� Gw H B b 6 GERTAINTEED" CEDAR f�V1810N DATE BREEZEKAY DEYON 8" 4� PERMA-CAST IMPRESSIONS AND 5" VINYL5/4" X 6" VINYL FREI E BD. COLUMN MON06RAMPSERIES H B 3 G SAVANNAH MICHAEL T- LOGAN HANDRAIL ® 3'-O" A.F.F. * 3 1/2" VINYL WINDOW 27 TORLEN COURT,HAUPPAUGE,NY 11788 BALLUSTERS® 5" O.G. MAX. SURROUNDS VINYL CLAPBOARD 5 DING I" X 12" AZEK FREIZE * 5 1/2" VINYL CORNER BDS. 631 979-2129 W/ I" X 4" AZEK TRIM W/ 114" ROUND EDGE 15T FLOOR ELEV.: tO'-O" — — — — — — — — — — — — (INSULATED) ARCHITECT IST FLOOR ELEV.: t0'-O" * INVISIVENT BEADED VINYL ' ® AZEK COLUMN ENCLOSURE SOFFIT VENT ❑❑❑❑❑❑❑o�❑a❑ PLANNER " t •,� oaooao❑o oo❑ T.O. R O. 5L ® 6 - 00 AB . EL: -2 6 - IF � ❑ ❑ :0 2 C� .. �y' 0o a o0 AR EL: �SLAB� 6 (V OL T0.5 �•<'• — CO UMNS �— STUCCO FINISH ON I 8" X 16" FOUNDATION G E * "H B d 6 PERMA-CAST ALL EXPOSED FLOOD VENT SMOOTH :,m COLUMNS PROJE-CT — CONCRETE I KUI ICK RESIDENCE BASE CAPITAL a ATTIC 1895 MINNEHAHA BOULEVARD GO CELLAR — ENTRY DOOR SOUTHOLD, NY 11971 BIL I— ___ - - - - - - - - - - - Tm.E W/5TEP — MODEL °B" —' ELEVATIONS 2" X 2" CEDAR LATTICE i REAR ELEVATION F, 50ALE: 1/4" - 1'-0" .ioa► O6:09 DRAWM NO. DATE 11121106 DRAWINGS ,5PEGIFIGATION5 AND OTHER DOCUMENTS (PREPARED BY THE ARCHITECT ARE THE IN5TRUMENT5 OF THE ARCHITECT'S 5ERV•ICE AND SHALL REMAIN THE PROPERTY OF THE ARGHITEGT,WHETHER OR NOT THE PROJECT FOR WHICH THEY ARE INTENDED A4 15 CONSTRUCTED OR NOT. THE ARCHITECTS DRAHINeS, SPECIFICATION5 AND SCALE f�5 NOTED OTHER DOCUMENTS HILL NOT BE USED ON ANY OTHER PROJECTS FOR ADDITIONS TO THIS PROJECT AND/OR FOR COMPLETION OF THIS PROJECT BY OTHERS, EXCEPT BY AGREEMENT IN HRITING AND HITH: APPROPRIATE COMPENSATION TO THE ARCHITECT. © GOPYRI C HT 2006 mAWNi sr l-Y. MARl?A I-0" CONT. RIDGE VENT RAKE BRICK CHIMNEY 4 COPPER STEP FLA5HIN6 ._... ... ._..... ... __... ....--- _-..... ........ . . _.... _... . _-_ - -----50 YR. ASPHALT — -...._ . _ . ._.... ...... . .. ._.._. _.. ._ .. .._...-_ _ ._ _ ROOF 5HINOLE5-- —� —. _.._:.....:_.. -. . _. .... . .._._„ -....._._ .q_...., BEYOND ®_- ..._E__ , .. 12 �. ___�._�_ _._ 12 - a - -- ASPHALT CRICKET:. CHIMNEY• � 2ND FLR. PL. ELEV.: +IQ'-ONI .... _. .. __- _ -_ -- - - - T.O.----6"-ALUM-6UTTER LEADER (TYPJ PL 0 2ND FLR ELEV: IT-O" Ilk 1'-4° 5/4" X 6" VINYL 5/4" X 6" VINYL 1'-4" O.H. GONT, RIDGE YENT5 BALCONY O.H. FREIZE FREIZE AZEK: 5/4" X b" — _ TOP GAP _ ----._--__ HIDDEN FLASHING 5 1/2"VINYL WINDOW SURROUN05(TYPJ ,. „� 50 YR. ASPHALT Q'1 LINE OF BALCONY PORCH Oj - _"-"ROOF 5HINGLE5- -"""" 6" ALUM. GUTTER/LEADER(TYP) CEDAR VINYL m IMPRE5510N5 CLAPBOARD 2ND FLOOR ELEV.: +10'-0" - - - - - - - '_ _ -_ "- 2ND FLOOR ELEV.: +10'-0" 15T A. PL. ELV.: +q'-O" IST FLR. PL. ELV.: +�.'-O" - T.O. PL. ELEV, ® PORCH +8''-O" .�.__.-_._ __•-•--_-..___._._...... HI�71P RETURN ROOF I it VINYL Ili I It IllGERTAINTEED CLAPBOARD 8"m H B d G PERMA-CAST CEDAR IMPRESSIONS SIDING DREEZEWAY I'-4" O.H. 5/4" X 4" FRIEZE BD. It COLUMN(TYP) Lj 1111 1111111 11, '1-,SHINGLES VINYL CLAPBOARD SIDING H B 4 G SAVANNAH `F� 5" VINYL CORNER BOARD W/ HANDRAIL SYSTEM I/4" ROUND EDGE - - (2) GOAGH-LIGHTS O ❑ ❑ � FJFJL El ❑EEI 11 F4� Hd FEI [E + W/MOTION DETECTING OPERATION m T.O. IfiT FL. ELEV.: t0'-O" ELEV. t0'-0" -0'-2" ❑ ❑ ❑ a � ❑Ll ❑ BALLUSTERS 0 ❑❑❑❑❑❑o❑000 5 FIN TUGGO n ..:••: ' TYP o000 0❑❑ 1 5 O.C. J ❑o❑ n ❑ ❑ IN. FL. ELEV 2 b 00 ao❑0000 0 0 t. X as 0 aooao UI 8 Ib FOUNDATION• ooao a ;y: O .— •f= D1YEN IN — LO F :istN Q STUCCO ooao ❑ ❑o❑oo❑o❑o 0 GRADE ❑❑oaoo . ... VINYL INSULATED FROST ❑❑ oaoo I I Z O.H. GARAGE DOOR 1 n i n n I COLUMN BASE ENCLOSURE .- 2-0 X S-O X S P.CONG. PAD ® BASE OF STAIR rn -- L-�- BLUESTONE d — —( CONCRETE STEPS 2" X 2" CEDAR LATTICE BILGO CELLAR 12" 0 50NOTUBE R 1 C HT S 1 DE ELEVATION ENTRY W,GONG. FOOTING STEPS MODEL "B" 50ALE: 1/4" = 1'-0" T.G. FLUE CEMENT WASH BRICK GAP 12 .f _..... .....,._. _ .ATTIC EXHA5T FAN _ BRICK CHIMNEY ..____.._....... _..... COPPER STEP _ _�---..--_•�---�-•_-�-_--,>s-:-_�.., , - - ...• .�: ....:......... ...� -. .:--.:...••., :-. FLASHING 2�, ND FLR. PL. ELEV.: +IQ'•O" _.. __�..,..... .... .,.^ . .,. .-,,. .,. .-. N. ,.,.,. ,.,,.x.. �._,.. ...._._._,....._.,,. _ _ - - -qr�i - - - - 2ND FLR. PL. ELEY.: +Iq'-0" _� VINYL CLAPBOARD --- - - -----------•----_-__._--_-__-- 51DING _____....___.__ _y-12 - DORMER ROOF a 12 - _50 YR. ASPHALT--_ FAMILY ROOM ROOF 5HIN6LE5 T. O. PL. ® DORMER EL. 50 YR. ASPHALT- - 12 -�- - -__--- _. ..._. __- __m-..-__. ___ --�. e ROOF SHINGLES__._ �I __._HIDDEN FLASHING—_ Q 7 _ " 5/4" X 6" VINYL FREIZE BD. ( P) • • £ � _.__ _-__.._.._-•...--_ ..-....____...__�-_ __— _._. ....-._ _.._.._._ T.O. PL. EL.+II 4 - --- HIDDEN FLA5HIN6 \ 2ND FLOOR ELEV.: +10'-0" — O'-O" FLR. PL. ELV.: +q'-0" ._..-... �_ ....-------•__-.-- _..—_.___._.__...._.._.. _ ___....__�_.._._. 1ST FLR FL. ELV i 2ND FLOOR ELEV.: 6 A_L-UM=6UTTER/LEADER.___ � — - — _ _— N-- —_�— —- _ -- - — — — — 4 �r 5" VINYL GORNEIR BD. 5/4" X 6"VINYL I'-4" O.H. 1'-4"O.H. GERTAINTEED Hill IALUM. GUTTER/LEADER l BIQ FZFI'1(f4Y�X �� l/l5F /2�12/06 FREIZE BOARD BREEZEWAY COLUMN (TY P)ERMA-CAST W/ I/4" ROUND EDGE (TYP) yMPRESSIONS 5/4" X 4" MAHOGONY DECKING MARK REVf810N DATE VINYL CLAPBOARD SIDING H B d G SAVANNAH HANDRAIL SYSTEM MICHAEL T_ LOGAN ® 56" A.F.F. (TYPJ FQn - W/BALLU5TERS 0 5" O.G. 27 YORLEN COURT,HAUPPAUGE, NY 11788 631 979-2129 EL. -0'-2" _ - - - 15T FLOOR ELEV.: 0'-0" I" X 4" AZEK I' X 12' AZEK —�i- ARCHITECT :.. 0000000013000 0000aa000000000a000000 oaoa0000000000000000aoa o❑❑ o a o a o aoo❑❑❑oa a ooao ❑oo❑a❑❑❑o❑❑ • •. . ,.. . ...•. ..... ., .,,., ,,.. ,-„ •`� o❑❑o❑0000❑o❑a❑a❑❑ ❑❑❑ ❑❑❑ooao❑❑❑❑❑ •; • c oo❑o❑❑❑❑❑❑o❑❑❑ ❑o ❑ o0 ❑❑❑❑a0000❑1 " ❑o❑o❑oo PL ANNER LA NN E R - o❑ a -b oa000aa❑0000000 ❑o ❑000000❑00000 EL a FIN. FIL � � '-i 000000000000000000000 ARA6E o 60000❑o❑o 0 o ❑ao o❑ 0000 no—, ooa000aa❑oao❑oo❑❑ ❑ ❑ 0 000000❑ ❑ ❑ o 000ao ❑❑o❑o a0000❑o 0 Ti1GC0 F 00 oa _ 000000❑00000❑❑o❑❑❑ooao ooao❑ o❑000000aoo❑❑o❑oo ❑00000❑o❑❑000❑❑oo❑❑o❑❑ o000000❑0❑❑ o a 0000a❑0000 ( n it GRADE � z 8 X Ib FOUND. FLOOD VENT I" X 12" d I" X 4" _ m I I I I II AZEK TRIM BD. I 12" xENCL0SURE AZEK COLUMN I C -1 — I I I I -J PROJECT KUILICK RESIDENCE — u 2" x 2" CEDAR LATTICE 189:5 MINNEHAHA BOULEVARD SO►UTHOLD, NY 11971 LEFT SIDE ELE\/ATICN- rnn EL 2'-0" x 8'-0" x a° ELEVATIONS P. CONC. PAD 5GALE: I/4" = I'-O" 00 ,SOB NO. Od:09 DRAWII l NO. DATE 1112//06 DRAWINGS , SPECIFICATIONS AND OTHER DOCUMENTS PREPARED BY THE ARCHITECT ARE THE IN97RUMENT5 OF THE ARCHITECT'S 5ER VICE AND SHALL REMAIN THE - PROPERTY OF THE ARCHITECT,HHETHER OR NOT THE PROJECT FOR WHICH THEY ARE INTENDED A5 IS CONSTRUCTED OR NOT. THE ARCHITECT'S DRiAWIN65, SPECIFICATIONS AND SCALE A OTHER DOCUMENTS WILL NOT BE: USED ON ANY OTHERPROJECTS FOR ADDITIONS TO 5 NOTED THIS PROJECT AND/OR FOR COMPLETION OF THIS PROJECT BY OTHERS, EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO THE ARCHITECT. © GOP RIGHT 2006 DRAwINerf hl. MARRA BRICK T.G. FLUE CHIMNEY CEMENT HASH CONT. RIDGE VENT BRICK GAP COPPER STEP FLA5HIN6 2" X 12" RIDGE ® CHIMNEY BRICK VENEER ASPHALT ROOF 2" X 5" G.J. ® 16" O.G. ON GONG. BLOCK CRICKET 2" X 10" R.R. R-50 BATT INSUL. ALUM. 6UTTER&EADER 12 I 12 1'-4- -7 / ( Q 1 TYP I I — — — — — — I _ 2ND FLR. PL`ELV.: +Iq'-O" ,k UP TO HIP 1/4" POST OPEN TO LEADERGUTTER 1 ® I: ® BEYOND " SEE DETAIL I,SHEET I FOR I I 4 INVI51-VENT BEADED COLUMN ANCHOR DETAIL I Q ~ VINYL 50FFIT(TYPJ HALL EilliQlmit \ 3 1/2" VINYL WINDOW 2" X 12,10 12" O.G. LINE I FLOOR I I \ SURROUNDS BY H/R-50 C. BATT INSUL. GERTAINTEED (T(P) 2 AIRSPACE ® GATH. GL6. � I ATTIC, FLOOR ELEVATION: +11'-O" — — — ELEV. +11'-0" T.O. GEILIN6 ELEVATION: +10_-0" _ _ _ 2ND FLOOR ELEV.- +10'-0" IST FLR. PL. ELV.: +q'-O" T.O. PL. ELEVATION: +5'-O" OL I'4" 5 1/2" VINYL CORNER BD. H/ O.H. OPEN ® 3050 S.G. ® 1/4" ROUND EDGE INVI51-VENT BEADED (KITCHEN BEYOND TO HALL Q I I DOOR VINYL SOFFIT(TYP) I v 4 • VINYL CEDAR IMPRESSION WOH B 6 PERMA-CAST I o FAMILY ROOM I I MASTER 510IN6 119 SMOOTH COLUMNS I^V I - o BEDROOM a \ VINYL HINDOH SURROUND GAP d BASE (TYP) PRGH 5" X 5" TRIMMED \ H B d 6 SAVANNAH HANDRAIL HOOD COLUMNS SYSTEM 0 56" A.F.F. T S 6 PLYWOOD SUBFLOOR F/P 3050 S.G. T 4 6 HOOD FLOORING DOOR OWNER TO SELECT \�j OL T.O. FIRST FLOOR _ IST FLOOR ELEV.: 10'-0" ELEVATION: t0'-O" I ELV. -2" — — 5/4" X 4" MAHOGONY DEGKIN6 1 ® PORCH DECK .4 : �:•. 5" X 5" J015T5 \. . ASH 1C.0. .a DAMPROOFIN6 BELOW 5 I/2" 5TL. " GRADE(TYPJ PIPE COLUMN PIPE COLUMN ,. °• IGRAK SPACE 5NGG0 FIN. ON GONG. ° /TJIFLOOR JOISTS 1. 2"" P. GONG. SCREED GOAT° W/R-Iq BATT. INSUL. (TYP) OIN V.V.B.OVER COMPACTED SOIL z :JFI Q •��.` F2 FI POURED CONC. FOOTING 1'-0" X 1'-0" PIER d FOUNDATION® FIREPLACE 10" P. GONG. FOUND. HALL ON 21-O" X 2'-0" X 1'-0" DP. NOTE: ON 10" X 20" POURED GONG. P. GONG. FT6. G T O A—A PLYWOOD SHEATHING(nP) FOOTING DAMPROOFIN6 5GALE: 1/4" = I'-O" GOMITINUOUS RIDGE VENT ROOF RAFTERS — 2" X 6" COLLAR TIES ® 16" O.G. �7P- — 12 2" X 10" R.R.a 16" O.G. -- Q'1 2" X 12" R.R. 0 16" O.G. 12 2" X 6" G.J. ® 1611 O.G. H/R-30G BATT INSUL. 7 VJ/R-30 GATT (2) 2" X 6" 5TRON65AOK (CONT) 1 T.O. PL. ELEVATION: +iq'-O" — — — — _ — 2ND FLR. PL_ELV.: +lq'-O" l I/2" GYP BD. ® WALL 1'-4" ---�- 12 AND GEILIN6 O.H. / ATTIC DOOR ® ® Q UJNFIN. �JTUDY Q RAFTERS %BFLOOR TO RIDGE `-TOR. �LYWOOD SHEATHING O.C.OF (TYP) 12" . H/R-50 G BATT IN5UL. 2" AIRSPACE 0 CATH. GL6. R 3 ATT171 F T.O.PL.® +II'-4" I" X 6" WOOD BASE -,��•f,, _ . O ATTIC FLOOR +11'-0" J R T 5/4" T 1 6 SUBFLOOR d. XcP f{.• .. e 77 O CEILING ELEV. ® KITCHEN : +10'-0" — — 2ND FLOOR ELEV.: +10'-O" I5T FLR. PL. ELV.: T.O. PL. ELEVATION: +5'-O" 4 LINE OF 5" X 5" COLUMN - — _ + 5 1/2" X 3 1/2" I I HL�ER a s BUILT-IN CLOSET BY OTHE *.. . O.H. POST ® +n'-4" I �? STAIR ID NING KIT HEN °oN HELLo . ' A MASTER 6L�5s M5TR. ROOM ( I 0 I " Y BEDROOM CAB. EVLo RE 8ATH IMPACT 2NL7 5IJ45MI55ION RF1/l5F /2�12/06 INSUL. CLASS 1WINDOW I I REF. MICROWAVE I ( w. I. CLOSET ISLAND 036 A.F.F. o Q l BRFFZEWA Y 8 X /O VINYL CLAPBOARD MAFgC SIDING WOOD" 1 1/4" CONC. 5ETTIN6 BED FIEV" DATE ' I I BASE H/C. TILE (RADIANT HEAT) OL 15T FLOOR ELEV.: t0'-o" _ L2 IST FLOOR ELEV.: o'-o"OL M�CHAEL T_ LOGAN -- — -- 27 TORLEN COURT,HAUPPAUGE,NY 11788 631 979-2129 LVL BEAMS ® R-Iq BATT® 3 1/2" 0 5TL. PIPE COLUMN COUNTER FLOOR J015T5 LVL BEAMS® (;� SPACE DAMPROOFIN6 ARCHITECT ISLAND ON4 W..e.o�GODMPGOAT ACMD SOIL PLANNER 3 1/2" 4) 5TL. 5 1/2" 0 5TL. m PIPE COLUMN PIPE COLUMN m . . MOM= KULICK RESIDENCE FI F2 FI 10" P. GONG. FOUND. HALL 1895 MINNEHAHA BOULEVARD �I 10" X 20" P. GONG. FT6. SOUTHOLD, NY 11971 C� E G T I O I `� 5-5 W,KEYWAY ME 50ALE: I/4" = I'-O" SECTIONS .roe NO. Od:09 DPAWM No. ` --- DATE 11121106 DRAHIN05 , SPECIFICATIONS AND OTHER DOCUMENTS (PREPARED BY THE ARCHITECT ARE THE IN5TRUMENT5 OF THE ARCHITECT'S 5ERVICE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT,WHETHER OR NOT THE PROJECT FOR WHICH THEY ARE INTENDED 15 CONSTRUCTED OR NOT. THE: ARCHITECT'S DRAPNINGS, SPECIFICATION5 AND SCALE 5 NOTFD A6 OTHER DOCUMENTS WILL NOT BE USED ON ANY OTHER PROJECT5 FOR ADDITIONS TO THIS PROJECT AND/OR FOR COMPLETION OF THIS PROJECT BY OTHERS, EXCEPT BY AGREEMENT IN HRITING AND HITH APPROPRIATE COMPENSATION TO THE ARCHITECT. © COPYRIGHT 2006 mAwNisy H. MARRA CONT. RIVC7E VENT — CONT. RIDGE VENT RAKE 2" X 6" COLLAR TIES ® 16" O.G. O.H. 2" X 10" ROOF RAFTERS LINE OF !DORMER O CONTINUOUS 2" X 6" HORIZJVERT. FAMILY(ROOM Q STRONGBACK5 ® ATTIC GLG. JOISTS 12 Q'7 \ 2" x 5" G.J. ® I6" o.c. \ SLOPED GL6. SSFI H / J57. \ \ T.O. PL. 2ND FLOOR .: +Iq'-O"- - H 6ER5 T.O. PL. 2ND FLOOR ,: +Iq'-O" OL 2" X 8" ROOF RAFTERS ® DECK W/SINGLE PLY RUBBER SURFACE 1 H B d 6 SAVANNAH HANDRAIL Q KbOD HANDRAIL EN PEN GL05. \ \ BEADED VENTED EN �„ A.F.F. T T ® \ BEADETED VINYL SYSTEM ® FRONT ELEVATION ONLY = �/ F . 5 IRO E SOFFIT(TYPJ SEE DETAIL 4 / / / BE W a UNFI1`y15HED 4 VINYL SIDING ON I/2" 12 V GAME ROOM \ \ 5TOfRAGE TUFF R BOARD SHEET A4 I / \ it 1/2" 6YP. BD. \ \ , (PAINT) 5/4" X 4" MAH060NY DECK / 3/4 -Tt i 6 PLYWOOD 5EGTIOINS REMOVABLE 11 " L Z50 YR. ARCHITECTURAL 12 3/4 T d 6 PLYWOOD ROOF 5HIN6LE5(TYPJ m 's�FLOOR EL ETH 50FLOORm - 2ND FLOOR ELEV.: +10'-0" ill 2ND ELEV.: +10-0" - - - - - b ALUM. 6UTTER/LEADER 15T FLR?, PL. ELV.: +q-O - _ - 15T FLR. PL. ELV.: +q'-0° 5/4" X 6" VINYL FREIZE _ TJI FLLR.J5E5. T.O. PL. ® GARAGE +8'� 1/2" GYP. BD. ON 30W ;AV R Iqq BATT - - - - WALL d CEILING 5.0. WOOD 2" X 811, G.J. (TYP) 8"m H EB d 6 F=RENGHWOOD I'-4" O.H. 5" VINYL CORNER BOARD 6"oCIO H INS 5L.6L. DR. 4 W A��� R DOOR �EDRLOOM #� 4 BREEZEWAY NU I/4" ROUND EDGE LA 4 MASTER BEDROOM Li 3/4" T d 6 PLYWDt.SUBLOOR Q Hs d 6 it 0. 1 1/4" SETTING BED PREPARE FOR GASRFET O EN' VINYL CLAPBOARD SIDING SAVANNAH LAUNDRY CABINETS TO W/DER. TILE 5/4" X 4"M PHO PORCH HANDRAIL I" X 6" BASE TRIM(TYPJ BE SELECTED BY OWNER o 0 0 DEGKIMI6® O ® 36" A.F.F. VINYL TRIM SURROUND 3/4" T $ G SUBFLOOR „ a I" X 6" BASE TRIM ❑ ❑ ❑ D ❑ El ❑ ❑ 3 1/2"® SIDE 5 1/2" o TOP 7 I X(oil BASE TRIM(TYP) (n,P J Q PREP FOR CARPET EL. -0- o 1ST FLOOR ELEV: t0'-O" iv ❑ E-1 ❑ ❑ ❑ ❑ I I/4" 1MAH060NY TRIM BD. R-Iq GATT INJ \ STUCCO FIN. , ❑ a ❑ ❑ ❑ ❑ 6ARA FIN. FL. ELEV.: t2'-6" DECK FLUSH FLUSH JOISTS ® GIRDER GIRDER dk TJI LO JOI TS G5 AGE „ GRADE a W/R GATT DRAWL SPACE STANDARD 6ARACE DOOR " 8" X 8" G.O. 2" P.CONG. 5GREED GOAT I VINYL INSULATED W/LITES ON V.V.B. OVER COMPACTED 501L in -17 NOTE: GLUE $ SCREW ALL T d 6 DAMPROOFIN6 PLYWOOD SHEATHING,(TYPJ SECTION G—G . T.G. FLUE SCALE: 1/4" = 1'-0" LINE OF ROOF CONSTRUCTION BEYOND CEMENT WASH GONT. RIDGE VENT BRICK GAP I'-O"O.H. 50 YR. ARCHITECTURAL 4 z ROOF SHINGLES 12 '_ '_ cv � VENEER BRICK 7� CONCRETE BLOCK 2" X 12" ROOF RAFTERS ASPHALT ROOF ASPHALT ROOF CRICKET HIDDEN METAL AND G1-6. JOISTS W/R 30- , CRICKET - - FLA5HIN6 BATT W/2" AIRSPACE / \ 12 - COPPER STEP FLA5HIN6 VINYL FREIZE BD. — \ Q l (TYPICAL) b" ALUM. 6UTTER/LEADER / \ _-` I FASCIA BD. AZEK 5/4" X 6" VINYL FREIZE 2ND FLR. FL. ELV.: +Iq'-O'_ - - - 2ND FLR. PL. ELV... +Iq'-O" - -- RIDGE VENT 2" X 10"' R.R. ® Ib" O.G. F05T UP TO BA73..1. 4 LINE OF DORMER " 12 �ROI NN�EGTION I'-O"RAKE ® FAMILY ROOM 5 VINYL CORNER BD. 2 ROWS OF CONT. W/ I/4" ROUND EDGE N.LFJ O INC /4 T d 6 PLYWD. O.H.(TYP) 2 X 6 ,OF CO T. 1 / ACCESS DOOR 2'-6" ® ATTIC 12 VINYL 51DIN6 / TO ATTIC p LF W/OAK „ 2" X 12" ROOF RAFTERS CLAPBOARD / 2' X R 4" WALL ATTIC/5TORAGE 4'-0" 1/2 WALL OR HANDRAIL FLOO No51NG 12 6 � SROOF 5HINCLE5GTURAL 1 Q'f / ® I6" O.G. ® 36" A.F.F.W/ \ 2" X 10"'G.J.. ® I6"O.G. BALLU5TER5® 5"O.G. " / 5/4" T d 6 PLYWOOD T.O. P . L. +I2 2" X 8" G.J. ® 12" O.G. W/ QI ROOF RAFTERS 2 AIRSPACE/ I 5U5FLOOR -�- . ATITIU,T R-Iq BATT EL. +II'-0" 4 " •r ® DORMER 'r ATTIC 5T0 6E 5/8 GYP. BD. "TYPE X" 2ND FLOOR ELEV.: +10'-0" _ - - \ 2ND FLOOR ELEV.: +10'-O" i / 1ST FLR PL. ELV.: +q'-0" 4 6" ALUM.G .UTTER&EADER i - - T.O. PLATE ® 6ARAOE / -- 15T FLR. FL. ELV.: +5'-O" / 8' ELEV. +8'-I 1/2" ELEV. +8'-I 1/2" R-30 BATT - J/ ... .. - - 5/6"TYPE"X" FIRECODE BEADED VINYL SOFFIT / ,...--- .. " ,;.•`; VENTS -r 6YP. BD.ON ALL WALLS 1 01-65. J' FAMILY ROOM o 1-4P. 2" X 4" WALL STUDS TWO-GAR GARAGE W/2n NC.5LAB BREEZEWAY BLUES TONE J/// 4 5 BEADED VINYLF 2ND 5UOMl55/ON REV ® 16" O.C. ® 6ARA6E _ _ _ _ _ _ _ _ = F 4 / P Y v ❑ T P RGH ® PORCH SOFFIT / l5E VINYL SAVING O BE O KIT HEN �_ BREEZElN.4 Y 8 X lO' l2�12�06 6 PL WOO H B 6 �AAFilC pEV1810N DATE II II II SUBFL R W/ SAVANNAH HANDRAIL LINE OF GARAGE DOOR BEYOND T d G AK F OR' I" ISLAND X 6" PC. - SYSTEM(TYP) T.O. B'WAY Q F/P BASE TRIM 5/4" X 4" MAHOGONY DEGKIN6 II " " „ II EL.: -0'-2'�I m (TYP) MICHAEL T_ LOGAN 4 P. GANG.SLAB W/6 X b 1.4 X 1.4 WWM ON V.V.B. EL, t0-O" PORCH ELEV.: -O'-2" II OVER COMPACTED SOIL II I % 27 TORLEN COURT,HAUPPAUGE,NY 117$8 11/4" MAHOGONY TRIM BD. 631 979-2129 GARAGE FIN. FL. ELEV.: '-6" ° 11 TJI FLOOR J5T5. W 5 I/2" 5TL. PIPE . / AZEK ENCLOSURE ® ALL SIDES R Iq GATT INSUL. JOISTS ARCHITECT . � COLUMN TRADITIONAL COLONIAL `' GRAWMSPACE TYPE FIREPLACE WITH ,4 P. CO c..=NAH D" X 8" WOOD TRIMMED DEEP MANTLE FOR FLAT GRADE H 2" P.GONG. SCREED GOAT PV FIN CO ON V.V.B. OVER COMPACTED 501E LUMN ® FAMILY ROOM SCREEN TVPLANNER m ! I I HANDF�AIL ISY5TEM a° •. ' U (_I ELEV. -6-4ft AAMJPROOFINO PROJECT A KULICK RESIDENCE FI FI 1895 MINNEHAHA BOULEVARD 5ECoolTION 0-0 FI 24" X 24" X 12" F2 36" X 36" X 18" P. GONG. FOOTING P.GONG. FTC. ® 8" X 8" P05T SOUTHOLD, NY 11971 SCALE: 1/4" = 1'-0" W/REBAR SEE FOUND. PLAN TRUE SECTIONS JOB NIO. Od:Oq DRAWW N0. DATE 11121106 " DRAWINGS ,SPECIFICATIONS AND OTHER DOCUMEINTS PREPARED BY THE ARCHITECT ARE THE IN5TRUMENT5 OF THE ARCHITECT'S S}ERVICE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT,WHETHER OR NOT THE MOJECT FOR WHICH THEY ARE INTENDED A7 15 CONSTRUCTED OR NOT. THE ARCHITECT'S CMAWING5, 5F'ECIFICATION5 AND SCALE5 NOTED OTHER DOCUMENTS WILL NOT BE USED ON ANY OTNER PROJECTS FOR ADDITIONS TO THIS PROJECT AND/OR FOR COMPLETION OF THISi PROJECT BY OTHERS, EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO THE ARCHITECT. O GOP RIGHT 2006 DRawNsy Hl. J�Ir4RRA