HomeMy WebLinkAbout32918-Z FORM NO. 4
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Office of the Building Inspector
Town Hall
Southold, N.Y.
CERTIFICATE OF OCCUPANCY
No: Z-32561 Date: 08/27/07
THIS CERTIFIES that the building ACCESSORY GARAGE
Location of Property: 52330 CR 48 SOUTHOLD
(HOUSE NO.) (STREET) (HAMLET)
County Tax Map No. 473889 Section 135 Block 3 Lot 18
Subdivision Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore
filed in this office dated APRIL 13, 2007 pursuant to which
Building Permit No. 32918-Z dated APRIL 18, 2007
was issued, and conforms to all of the requirements of the applicable
provisions of the law. The occupancy for which this certificate is issued
is UNHEATED ACCESSORY GARAGE IN THE REQUIRED REAR YARD AS APPLIED FOR.
The certificate is issued to GEORGE & KYRIAKI MANIKAS
(OWNER)
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A
ELECTRICAL CERTIFICATE NO. 3034732 08/1.3/07
PLUMBERS CERTIFICATION DATED N/A
tho ized ignature
Rev. 1/81
Form No.6
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
765-1802
APPLICATION FOR CERTIFICATE OF OCCUPANCY
This application must be filled in by typewriter or ink and submitted to the Building Department with the following:
A. For new building or new use:
1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or
topographic features.
2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form).
3. Approval of electrical installation from Board of Fire Underwriters.
4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead.
5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate
of Code Compliance from ardhitect or engineer responsible for the building.
6. Submit Planning Board Approval of completed site plan requirements.
B. For existing buildings (prior to April 9, 1957) non=conforming uses, or buildings and "pre-existing" land uses:
1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic
features.
2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is
denied; the Building Inspector shall state the reasons therefor in-writing to the applicant.
C. Fees
1. Certificate of Occupancy-New dwelling$25.00, Additions to dwelling$25.00, Alterations to dwelling$25.00,
Swimming pool $25.00, Accessory building$25.00, Additions to accessory building$25.00, Businesses $50.00.
2. Certificate of Occupancy on Pre-existing Building- $100.00
3. Copy of Certificate of Occupancy-$.25
4. Updated Certificate of Occupancy- $50.00
5. Temporary Certificate of Occupancy-Residential $15.00, Commercial$15.00
Date. cZ y Ape a a-
New Construction: Old or Pre-existing Building: (check one)
Location of Property: S a S3 9 RT 98 S'ayrNo�p
House No. Street Hamlet
Owner or Owners of Property: Genes ra 4 hi IAkI mRAI ki% S
Suffolk County Tax Map No 1000, Section _q 73 8 8 q Block 0003 Lot_ 01%
Subdivision Filed Map. Lot:
Permit No. ,3 el $ Date of Permit._ 18 A f g O j- Applicant:
Health Dept. Approval: Underwriters Approval:
Planning Board Approval:
Request for: Temporary Certificate Final Certificate: (check one)
Fee Submitted: $
JOEL DALY HOME IMPROVEMENTS
205 BOISSEAU AVE. cant Signature
a� P.O. BOX 343
5� SOUTHOLD, NY 11971
FORM NO. 3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Town Hall
Southold, N.Y.
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL
COMPLETION OF THE WORK AUTHORIZED)
PERMIT NO. 32918 Z Date APRIL 18, 2007
Permission is hereby granted to :
GEORGE & KYRIAKI MANIKAS
PO BOX 920
SOUTHOLD,NY 11971
for
CONSTRUCTION OF AN UNHEATED ACCY GARAGE IN THE REQUIRED REAR YARD
AS APPLIED FOR
at premises located at 52330 CR 48 SOUTHOLD
County Tax Map No. 473889 Section 135 Block 0003 Lot No. 018
pursuant to application dated APRIL 13 , 2007 and approved by the
Building Inspector to expire on OCTOBER 18, 2008 .
Fee $ 130 . 40
Authorized Signature
ORIGINAL
Rev. 5/8/02
rJ��PrJ��J"rJ�r�rWleJ�WW�WOUl�cPr�r�r�r�elrJr.PedrJ��1'rl'e1 RIVE Pr�r�rJrJ�enr�r�rJ�r�rdrJ�r�rJ�rJr!'r�r!'rJ�e1�rJ�r.PrJ�rJ�rJ �rJ�el�el�rJ�cJ�rJrr3 I�
5 BY TI-1'IS CERTIFICATE OF COMPLIANCE THE 5
5
5 NEW YORK BOARD OF FIRE UNDERWRITERS �
5BUREAU
OF ELECTRICITY5
5 40 FULTON STREET - NEW YORK, NY 10038 c
11
5 CERTIFIES THAT 5
S S
Upon the application of upon premises owned by 5
NJ
5
5 ,DOROSKI ELEC. INC GEORGE MANI'KAS
5 P.O. BOX 781 52330 COUNTY ROAD 48 5
5 CUTCHOGUE, NY 11935, SOUTHOLD, NY 11971 5
5 5 Located at 52330 COUNTY ROAD 48 SOUTHOLD, NY 11971 5
e5Application.Number: Certificate Number:
RP. 3034732 3034732 c�
SSection: Block: Lot: Building Permit: BDC: ns11 S
5
,3c)-
� 5
5 Described as a occupancy, wherein the premises electrical system consisting of
5 electrical devices and wiring, described below, located in/on the premises at: 5
C5 5
5 First Floor;Second Floor,garage,Detached Garage,Outside;, SS
5 5 A visual inspection of the premises electrical system, limited to electrical-devices and wiring to the-extent, detailed 5
herein, was conducted in accordance with the requirements of the applicable code and/or standard
5 promulgated by the State of ,New York, Department of State Code Enforcement and Administration, or other
5 authority having jurisdiction, and found to be in compliance therewith on the Day of
13th August,2007. 5 ,
5 Name QTY Rate Rating Circuit Tyne 5
5 Wiring and,Devices C5
5 Outlet '7 0 Fixture 5
5 Fixture 7 0 Incandescent 5
5 Outlet 8 0 General Purpose 5
5 Receptacle 6 6 General Purpose S
5 Switch 4 0 General Purpose S
5 Receptacle 1 0 GFCI S
5 5
5 S
5 5
5 5,
5 5
5 seal 5
5 1 of 1 5
5 _ 5
SThis certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. S
5 5
o ��������Lffl- ��Ln�������������������������������������LPCPLPr ����� 1111
ll of soar
� o
�'YOOUMY,�c�
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] 1 LATION
[ ] FRAMING / STRAPPING [ FINAL
[ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
REMARKS: C�� -
DATE ® INSPECTOR
sooryo
coutm,
• ao
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLOG.
[ ] FO DATION 2ND [ ] INSULATION
[ FRAMING / STRAPPING [ ] FINAL
[ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
REMARKS: 24 zz
DATE -61310 INSPECTOR
l�� pF SOUlyO
h� �O
ho
OOUMY,��Q
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
,'�AUSPECTION
[ FOUNDATION 1ST [ ] ROUGH PLOG.
[ ] FOUNDATION 2ND [ ] INSULATION
[ ] FRAMING / STRAPPING [ ] FINAL
[ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
REMARKS:
DATE INSPECTOR.
FIELD INSPECTION REPORT DATE COMMENTS
�b
FOUNDATION(1ST)
I'N�
------------------------------------
FOUNDATION (2ND)
LN
Co
ROUGH FRAMING& .m
PLUMBING y
r
INSULATION PER N.Y.
STATE ENERGY CODE
a
FINAL Lool
ADDITIONAL COMMENTS
O
Z
O m
z
h
x
d
b
�-3
TOWN OF SOUTHOLD PROPERTY RECORD CAR
OWNER STREET d VILLAGE DIST. SUB. LOT
FORMER OWNER N� E �
ACR
-;' ,./
-
S Y. n ✓' TYPE OF BUILDING
o1
RES.a/o SEAS. VL. FARM' COMM. CB. MICS. Mkt. Value
LAND IMP. TOTAL DATE REMARKS
.6" 00 �:%
U U CX 9 Q U
r
s 5 - 79 9 p,4 a4 - Sw�w'N
/Am " kc�s
olaT i a,) -Z,
AGE BUILDING CONDITION
NEW NORMAL BELOW ABOVE
FARM Acre Value Per Value
Acre i
Tillable FRONTAGE ON WATER
Woodland FRONTAGE ON ROAD p a -
Meadowland DEPTH I
House Plot BULKHEAD
Total DOCK
,•�.� N
a /►j�v %��''.vim+� • •
02
MEN
MEN■■■■■■■■■■■■■■■■■■ NONE■
�'� ■■MIME■■■NEM■■■E■■■■■M■■ NOON■
k .....�j� ■■E■E■E■■ME■■E■■■E■■■■■ ■ENE■
1 mom
NEON IMMEEMESS 0 MEMO mom
M! NONE
MIMENSEEMEMINIMMIMME
BME s OREM ME
EE■E■IMe■■■I�M■ME■M■ No No
.■■■MEN■EEIi■■■E■■■ N■■■ME■.■■
..■■■■m®lmuffim■■■I1r ■..■■■Ell
■■■■■15r,55amm ONE ME ■No
MEN
■■■
O
recition Roo
mer
..
TOWN OF SOUTHOLD • BUILDING PERMIT APPLICATION CHECKLIST
BUILDING DEPARTMENT Do you have or need the following,before applying?
i-PR 13 20QT
TOWN HALL Board of Health
SOUTHOLD,NY 11971 4 sets of Building Plans
TEL: (631) 765-1802 Planning Board approval
FAX: (631) 765-9502 Survey
www. northfork.net/Southold/ PERMIT NO. , 3C?y/F-,rs::�r Check
Septic Form
N.Y.S.D.E.C.
Trustees
Examined 1120 67 Contact:
Approved 20 0 Mail to:
Disapproved a/c
Phone:
Expiration fV1191220LO-e
Building Inspector
APPLICATION FOR BUILDING PERMIT
Date. , 20_
INSTRUCTIONS
a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4
sits of plans, accurate plot plan to scale. Fee according to schedule.
b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or
areas, and waterways.
c. The work covered by this application may not be commenced before issuance of Building Permit.
d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit
shall be kept on the premises available for inspection throughout the work.
e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector
issues a Certificate of Occupancy.
f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the
property have been enacted in the interim,the B I u'ilding Inspector may authorize, in writing,the extension of the permit for an
addition six months. Thereafter, a new permit shall be required.
APPLICATION IS HEREBY MADE't6 the Building Department for the issuance of a Building
ing Permit pursuant to the
Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or
Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described.The
applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations, and to admit
authorized inspectors on premises and in building for necessary inspections.
(Signature of applicant or name,if a corporation)
(Mailing address of applicant)
State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder
GCC%t E G C_r3 r%-C r A 0 14—
Name of owner of premises Gcome_ Ma,tjPycie.
(As on the tax roll or latest deed)
If applicant is a corporation, signature of duly authorized-officer
(Name and title of corporate officer)
Builders License No. 1 :306 8 1-k
Plumbers License No.
Electricians License No.
Other Trade's License No.
1. Location of land on which proposed work will be done:
— 5a330 CR Lio 500-r�"JICA r4 119-7
House Number Street Hamlet
County Tax Map No. 1000 Section I SS Block 03 'Lot ot
Subdivision Filed Map No. Lot.
(Name)
2. State existing use and occupancy of premises and intended use and occupancy of proposed construction:
a. Existing use and occupancy tAc-L-1 L o n srTV UC-.-t% g
b. Intended use and occupancy Sq%AA Two c_ar aora%1t. / Rr_ a0C_ E.c,str,Ws sCAb
3. Nature of work(check which applicable): New Building X Addition Alteration
Repair Removal Demolition Other Work
(Description)
4. Estimated Cost J1 a 61 5-00 �� Fee
(To be paid on filing this application)
5. If dwelling, number of dwelling units N Number of dwelling units on each floor
If garage, number of cars o�
6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. A
7. Dimensions of existing structures, if any: Front - Rear Depth
Height Number of Stories
Dimensions of same structure with alterations or additions: Front Rear
Depth Height Number of Stories
8. Dimensions of entire new construction: Front oZ y Rear 414 Depth A`1
Height 1 l Number of Stories ' 2
9. Size of lot: Front bb Rear bb Depth .310 . 6(o
M
10. Date of Purchase Name of Former Owner St+rt t--r
11. Zone or use district in which premises are situated A
12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 7�
13. Will lot be re-graded? YES NO Will excess fill be removed from premises? YES NO
14. Names of Owner of premises- M mt. aw jk-S Address---Vo'Bo.,,uo spa,hj Phone No. 15 1- --916- al s
Name of Architect Addresses u—,t hc,s_�,=,-_14—Phone No 931 734 a 7 9 I
Name of Contractor o Address ao s' Phone No. 4 ...! 7 4;5' i g-g�9_
So to At0•f
15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO X
* IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED.
b. Is this property within 300 feet of a tidal wetland? * YES NO__/�_
* IF YES, D.E.C. PERMITS MAY BE REQUIRED.
16. Provide survey, to scale, with accurate foundation plan and distances to property lines.
17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey.
STATE OF NEW YORK)
SS:
COUNTY OF J W
\0e ( ►K r oolq being duly sworn, deposes and says that(s)he is the applicant
(Name of individual signinj contract) above named,
(S)He is the C Ada( (l e,- O�
(Contractor,Agent, Corporate Officer, etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;
that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be
performed in the manner set forth in the application filed therewith.
Sworn t before me this-
3 — day of �l� j 20OJ
Nota ublic gnature of Appaant
MELANIE DOROSKI
NOTARY PUBLIC,State of New York
No.01 D04634870
Qualified in Suffolk Coun �1 b
Commission Expires September '0,
W
r�
N
0"9d. SURVEY OF PROPERTY
A T SO UTHOLD
0�9 6od \ TOWN OF SO UTHOLD
6 \ SUFFOLK COUNTY, N. Y.
1000-135-03-18
04�, � o \ MARCH 19, 2007
o \
e �
RQ�
°F\
Raa ti� QP� G' ��k �• ��O\
,k y
tii0 \10a+6,, \
F NEW
ME
AREA=20 of $0. FT. l 9 18
ANY ALTERATION OR ADD177ON TO THIS SURVEY IS A VIOLA77ON CONIC SUR YOR
OF.SECTION•72096F THE NEW YORK STATE EDUCA77ON LAW
EXCEPT AS PER S0776N 7209-SUBpIV1SlON 2. ALL CER11F/CATIONS _ :.,. ,�0� (631) 765-5020 FAX
.HEREON ARE: "NAL/D• FOR THIS.MAP AND COPIES THEREOF ONLY IF ch'� F, am P.O. BOX 909
SAID MAP.OR COPIES BEAR WE IMPRESSED SEAL -OF THE SURVEYOR vao pC' 1230 TRA I/ELER STREET
WHOSE SIGNATURE'APPEARS HEREON. =MONUMENT SOUTH. OLD, N.Y. 11971 07 127
N
�oMir SURVEY OF PROPERTY
AT SO UTHOLD
0�9 lb, \ TOWN OF SO UTHOLD
I 6 \ SUFFOLK COUNTY MY
1000-135-03 18
SCALE. 1 —30
MARCH 19, 2007
040
OF Neby
PIE
�� X ryry1 Tj�• \
ti
0
AREA=20;501. 80. FT. s 18
ANY ALTERATION OR ADDITION TO THIS SURVEY IS A WOLA77ON 0 O CONIC SUR P
OF SEC77ON 7209OF THE NEW YORK STATE EDUCATION LAW.
EXCEPT AS PER SEC77ON 7209—SUBDIVISION 2.* ALL CER77FICA77ONS +0 (631) 765-5020 97
HEREON ARE VALID FOR THIS MAP AND COPIES THEREOF ONLY IF ch''���. �� P.O. BOX 909
SAID MAP OR COPIES BEAR THE IMPRESSED SEAL -OF THE SURVEYOR 1230 TRA I/ELER STREET
WHOSE SICNA7URE APPEARS HEREON. ■=MONUMENT SOUTHOLD, N. Y. 11971 0 12`
r
t
1`
LU Z
=3 G
U (S") CV
s o �
Q °C 0
NAILING SCHEDULE PLAN CGN TENTS: .o
GENERALNOTES WIND FRAMING NOTES ROOF FRAMING: 0 GUPANCY CI_A-JSIf'I ATION R3 RESIDENTIAL 3:1).RIDGE-TO-RAFTER ASSEMBLY: BUILDING USE WELLING N 1-1/4"x 20 gauge strap shalt be attached to each pair of rafters in as irdance to table 3.4. JOINT DESCRIPTION NAIL NAIL NOTES
When a collar tie Is used In leu of a ridge strap,the number of 10d airman na:!s required CITY. SPACING BUILDING HEIGHT R
CONSTRUCTION NOTES: In each end cf the collar to need not exceed the tnbulal^d number of 8d nars In the strap. RAFTER TO B'WALL 3-8d CO YMON EACH TOTAL SO. FT. OF CONSTRUCTION
TOP PLATE 10'WALL:4-6d CO".414QN RAFTER TOG-NAIL
1).The irforma5on within this set of construction documents Is related to basic design 2).RAFTER-TO-WALL ASSEMBLY: PRESCRIPTIVE AS PER N.Y.S. RESIDENTIAL CONSTRUCTION COC, . AND
DESIGN CRITERIA 1995
intent and fram(n details.The anj intended as a construction aid,not a substi?ute lateral framingand shearwa!I connections formf`er,ceT or truss Ito 'ate shall he in CEILING JOIST 8'WALL:3-8d COMMON EACH TOE-NAIL ° SBC HIGH V"ND EDITION, WOOD FRAt�CONSTRUCT!ON MANUAL
for generally accepted good building practice and compliance with current New York accodance t table 3.3.When a rafter or truss do not fail i n line Kith sheds below,rafters TO TOP PLATE 10'WALL 4-8d COMMON JOIST
State building codes.The General Contractor is responsible for providing standard or trusses shalt be attached to the wall tap plate and the wall tcp plate shall be attached to CEILING JOIST TO AS PER TABLE 3.7 EACH FACE FRAMING ELEMENT AS PER PLANS, CROSS SECTION A.N GENERAL NOTES
construction det,0s and procedures to ensure a professionany finished,structurally the to the wall stud with On conne e rake
rtions.Roofs overhanging the side of the buiildfrg PARALLEL RAFTER W,'FCM-S�!C LAP NAIL EXT. BALCONNIESIES 60
s-,rid and a weatherproof completed product. shall be cxnected with uplift connections in accordance with table 3.3c. CEILING JOIST LAPS AS PER TABLE 3.7 EACH FACE DECKS 40
2).The General Contractor is responsible for ensuring that all work and constriction 3).WALL-TO-V'JALL ASSEMBLY: OVER PARTITION VXCM-SB!C LAP NA n ATTICS w/o STORAGE 10
meets current federal,state,county and local codes,ordinances and regulations,etc. War studs above and studs below a floor level shall be attached with lift corrections in COLLAR TIE AS PER TABLE 3.4 EACH FACE ATTICS w/ STORAGE 20
g �' 'FCM-S'tC END NAIL DESIGN LOAD CALCULATIONS
These codes are to be corrs'dercd as part of the specifications for this bui!dfng and accordance with babes 3.3b.When wag studs above do not fait in Ihme with studs bellow,the TO RAFTER Vti ROOF (GROUND SNOW LOAD) 45
should be adhered to even if in variance with the plan. s'ruds shall be attached to a common mernber in the floor assembly with up'dt connectors In BLOCKING EACH TOE (LIVE LOADS PSF) ROOMS OTHER THAN SLEEPING 40
..-
accordance with table 3.3. TO RAFTER 2-8d COMMION END tJAn-_ ROOMS (SLEEPING) 30
3),Oimens?ors shall take precedert over scaled drawings. RIM BOARD EACH END
(DO NOT SCALE DRAWINGS). 4).WALL ASSEMBLY TO FOUNDATION: TO RAFTER 2 ,`,1 CONINMN END I NAIL STAIRS 40 7-
Firs'wall studs she'I be connected to the foundation,01 pate,or bottom plate with up"ft - GAURDRAtLS (ANY DIRECTION) 200
4).The engineer has not been engaged for cons•r,aeon supervision and assumes no connectors.Steel straps shall have a minimum embedment of 7 inches In concrete WALL FRAMING: EXPOSURECA TAGORY (;1
resporslbIlAy for construction coordinating with these plans,rrmr responsfbi':ty for foundation and slab-on•grade,15 inches in masonry block foundations,or lapped under - - ---
construction means,methods,techniques,sequences,or procedures,or for safety t'le plate and nailed in accordance with table 3.3b.When steel straps are lapped under the JOINT DESCRIPTION NAIL NAIL NOTES LOAD PATH SEE CONSTRUCTi0N ANDW!ND PATH CONNECTION
precautions and rams In connection with the work.There are no warranties for a bottom late,3 Inch ua^e washes shall be used with the anchor belts.Anchor boR CITY(. SPACING
p Dreg P� sq'� ROOF - FOUNDATION DETAIL PAGE & GENERAL NOTE PAGE ..... �
specific use a rt ssed or implied in the use of these ans. spacing is t be s cod and sized In accordance to table 3.2a.In addition to spacing, TOP PLATE TO "� PER FACE NAIL O
pe xp p plans. g Pa2-16d COtft ON
anchor bolts are to be spaced between 6-12 inches from the end of a sill plate and an TOP PLATE FOOT SEE NOTE:1 NAILING SCHEDULE SEE ENERAL NOTE PAGE
5).Refer to the Window and Door schedule for exterior openings. comers. TOP PLATES AT JOINTS FACE EGRESS SEE FLOOR PLANS AND WINDOW SCHEDULE
INTERSECTIONS EA.SIDE NF,IL Q�
6}.The General Contractor is to ensure that masonry or prefabracted fireplaces meets 5).TYPE I EXTERIOR SHEARWALL CONNECIiONS: FIRE PROTECTION
STUD TO 24" FACE SEE FLOOR PLANS �-
c,r exceeds manufacture's rdactficaticns and applicable codes. Type I exterior shear walls with a minimum of 7116 inch wood structural panel on the exterior STUD 2- :6d COi!,.��ON O.C. NAIL SMOKE do CO2 DETECTORS �
attached with 8d common nails at 6"o.c.at the panel ecges and 12"o.c.in the field,and TRUSS DESIGN N A - STANDARD STICK FRAME CONSTRUCTION
7).The General Contractor is to consult with the owvner for an built-In items 1/2 inch sum wallboard on the irterior attached with 5d cooler nags at 7"o.c.at ,nel HEADER TO ,� 16,O.C. FACE - Q' ( �+.�
9YP r •ncn P df HEADER 16d COM,lICN ALONG EDGES NAIL ENERGY CALCULATIONS R 5 HE K RELEASE 1
such as bookcases,shelving,pantry,dasets,trims,etc. edges and 10"o.c.in G`re field shag too In accordance wf,h the length require• is spe.�,.ed __ � •
in table 3.15a-b. TOP OR BOTTOM 2-16d CO"!IWON PER 2x4 STUD END ! rt
8).VAnd load regvirempn!s shall be taken into account during construction. PLATE i u STUD 3-16d COMMON PER 2x6 STUD NAIL
- - 6).TYPE 11 EXTERIOR SHEARWALL CONNECTIONS: BOTTOM PLATE TO: �!
FOUNDATION NOTES: Type II exterior shearwags shall meet Pe requirements of table 3.159-b times the apprvpriMe FLOOR JOIST,BAND JOIST, 2-16d CV1,P'ON PER FACE NAIL
1).The General Contractor and Mason to review plans,elevatcns,details and notes to length adjustment factors in table 315. FOOT SFE NO M:1,2
t �` j � END JOIST OR BLOCKING
de"f,rmine intr•mded heights of finished floors)above typical grade. 7).INTERIOR SHEAt fNALL CONNECTIONS: FLOOR FRAMING: N1
Ai!ewabte s?de++gin tent?hs provided in tnbte 3.14 shall be permitted to be Increased when , ,
2).All footings to rest on undisturbed(virgin)son.Assumed bearing 3000psf interior shearwors are used.Sheathing and connections shall be in accordance wit JOINT DESCRIPTION NAIL FAIL NOTES
QTfY. SPACING �
Z.4.4.2and22.4rospectve!y. CLIMATIC & GEOGRAPHIC DESIGN CRITERIAto
3}.Provide 12'expansion joint material between concrete stabs and abutting JOIST TO: I P:"R TOE _
concrete or mason walls occuri In exterior or unheated Interior areas. 4-Sri C(Oht4fOi:
ry n9 8 .CONNECTIONS AROUND EXTERIOR VVAIt OPENINGS: SILL,TOP PLATE OR GIRDER JOIST NAIL GROUND WIND SEISMIC FROST Vt'i,NTER I ICESHIEt-D FOOD
Header and!or g'rdei connections shalt tie attached wvi h uolfft connections in accordance BR'DGiNG EACH TOE SNOW SPEED DESIGN WEATHERING LINE TERMITE DECAY DESIGN UNDERLAYMENT
4).Any new concrete walls bei-mg attached to existing concrete structure shall with table 3.5.Wroclaw sift pintes shall be have stc*M connectors in acco*dance with Gabfe TO JOIST 2-6d C(OM MN END NAIL LOAD (MPH) CATEGORY DEPTH TEMP. REQUII.ED HAZARDS til J
be hmrtalled*10#d re-bar,18'long at 12"o.c..Use approved epoxy for installation. 3.5.
BLOCKING EACH TOE MODERATE SLIGHT TO
2-8d CCOM"40N 45 LBS. 120 B SEVERE 3 FT. -
5).Unless othembse noted,all s!abs on grade to be 2500 p.s.b..Concrete to be g).CATHEDRA! CEILING ASSEt446LY: TO JOIST END NAIL
poured on 4 lnc'i thick sand or gravel Ft!with 6x6 wore mesh reinforcing.Interior slabs Where a ridge is to be used as a structural beam,the rafters shag either be notched and w TO HEAVY MODERATE
BLOCKING TO: EACH TOE
t be minimum 3-1/2 inch thick. „ t 3-16d CCbf it OrI L
anchored on top of the beam or slope asrrrcct�rs shalt be attached to each roc.Ar-to-ridgA Sl.l OR TOP PLATE BOCK NAiL
along the open gelling part of the building.Connections to the rid?e and wait shall be be LEDGER STRIP EACH FACE ROOF SHEATHING REQUIREMENTS FOR WIND LOADS:
6).Crawl spices to be provided with a minimum 18W4'access opening.Install one attached with tare above requirements. TO BEf,M 3-16d G OM"AON
JOIST -NAIL i " _
NAIL SPACING NAIL SPACING AT tt.TER 'E'DIATE
8x16 cast Iron foundation vent for every 150 sq.R.of area. SHEATHING LOCATION '" -
DECK AND COVERED PORCH NOTES: JOIST ON LEDGER, 3-8d CC 11VON PER TOE AT PANEL EDGES SUPPORTS iN THE PANEL FIELD NOTES
7).Dampproof exterior of fo ndatic,,with bituminous coating as per section R406 of TO BEAM JOIST NAIL 4'PERiMIE ER EDGE ZONE 8:1 COWAON 6-O.C. 8d COVIM "�? O,J(,7)till O.C. SEE NOTES:1,3
N,Y.S.Residential Construclion Code.A 6-mil potyethy'ene film shalt be eppried over 1).Unless otherwise noted,all framing material to be#1 AGO pressure trea+3d lumber. BAND JOIST PER END SEE NOTES:1(POTH FIEL03,
the below g,ado portion a:exteric- --ales prior to backf l!!ng. All fasteners,hangers and anchors t be,,.Iv nized or stainless steel. 3-16d CCOM',14N INTERIOR ZONE 8d COWJON 6"O.C. 8d COMMON 12"O.C. +
r►9 A' TO JOIST JOIST NAIL NOTE 2 FOR PANEL FIELD AILL CONSTRUCTION SHALL
�. ,f , BAND JOIST TO: " PER TOE NAIL GALL E ENDWALL RAKE AND RAKE TRUSS 8d CON!f 40N r.4"O.C. Sd COf1MON a.4"
8).Drr'nage as oer;Pction R405 of N.Y.S.ResidAn.sal Cerstnuction Colo. 2).Grders for deck jals.s to be bolted to each past with waSlmers and nuts. 2-18d CCOM',.O J C` C? O.C. SEE NOTES:1,3 EEl THE REQUIREMENTS OF THE
�-�- Girders on concrete piers shah be anchored with proper steel cornectors anchored SILL OR TOP PLATE FOOT SEE NOTE:1
FRAMING NOTES into concrete with a minimum 112"dia x 7'long anchor bolt wrath washers and nuts. R0O F SHEATHING: NOTES =' CODES OF NEW YORK STATE.
1).All framing techniques and methods as prescriptive design of 1995 SBC High Wind 3).Posts supporting girders shag be anchored to a 12"xl?x12"thick concrete footing. JOINT DESCRIPTION NAIL NAi!'L NOTES THESE NOTES ARE ONLY TO GE REFERRED TO IF MENTIONED IN SCHEDULE NOTES ONLY.
Edt'on Wood Framing Construction Manual. Use a m)nlrr.um 12"din x 7"tong anchor bolt wtlh washers and nuts.Footings Shag QTY. SPACI ING
be 3 ft.below grade.Concrete piers t be used with all porches!decks with roofs or pergulas. STRUCTURAL PANEL g j AS PER TAIPLE 3.8 1).For root sheathing w"Cmin 4 fart of the perimeter edUe of the roof,Inducting 4 tent on each side of the roof peak,
2).Unless otherwise noted,all framing and structural wood mat^rial to be#2+BTR. WFCM--SBC the 4 foot perimcter edge zone a'tach,mbn„s required she!!be used. CY O R t3 !�'rill f'j r p i C TL°D�y
0,u las Fir. r OCCUPANCY ' htt Pl t � ?'t«l j L:LJ
g 4).Deck joists to have blocking at e'o°•�•. CEILING SH OATH I NG:,
2).Tabulated 12 Inch o.c.nag spa.�ng essumPs shAat~fng attached t rafter/truss iraming a;+• 9.
3).Floers,walls,ceilings and ra^er;to be spaced at 16 Inches o.c.ur!ess noted 5).A minimum of 10 inch flashing shag be instaled brtw�+nn the building and ledger. NAIL NAIL For fra^r!ng members wPJt<0.42<G<0.49,the n.^.!i spacing shau tie re ed t 6�, es o.�," 'J8 j�'�`N LAWFU L DATE:
JOINT DESCRIPTION NOTES
otherwise. Ledger t be fastened to building with 17 dial.bolts with washers and nuts CITY. ;SPACING � c wn ^
r GYPSUM 7' O.C.EDGE 3).Tahrul,-..ed 4 inch o.c.nail snaring a�..umes shea`h? to r.._r/Muss framing members w�►l T�� E: J�3 0• � q �-G�
where needed. * nil g I
4).Unless otherwise noted,-It bearing wallheaders t be(2)2x10#2+BTR.Doug.nr. 5d COOLERS � framing members with 0 42<G<0 49,the nail spitc!Erg shaft be reduced to 3 Inches o.�. CUT C E RTI FI C) 71-
Bearing wn'i headers t have(2)Jack studs and(2)full length WALLBOARD 1Q"'O.0.FIELD P IFY E
h studs on each side of a!1 6)•Concrete piers shin be a mintmum 6 above grade. c AT
openings.LVL headers t have(3)jack studs and(2)full length studs on each side of WALL SHEATHING: OF OCCUPANCY 76v t,n t f f - THE
openings.Bearing waif window sills shall also have(2)Whdow sit!plates for 2x4 wig 7).Aft joists to be supported with hangers and anchors,Each Joist shall also be anchored
openings Whw>pn 4'1 and 6'0 and 2x6 will openings bM-vgTn 5'11 and 8'9.Prov'rdo fire to glyde s. JOINT DESCRIPTION NA'L NAIL NOTES r ( FCLL'✓'`''^ii' "
and blocking where app!!cablP.
n ) QTY. SPACING WALL SHEATHING REQUIREMENTS FOR Vir!ND LOADS: FC'_'
8).Covered Roofs shag be assembled and anchored the same manner as a typical buId'ng. STRUCTURAL 8d COMMON AS;PER TABLE 3.9 SHEATHING LOCATION NAIL SPACING N41L SPACING AT INTERMEDfATE NOTES FCR Ell'
ir -
5).All flh beamsiheadrrs to be instannd oath heavy duty ga!vin,zed hangers and PANELS !WFCM-SBC
AT PAfJL1 EDGES SUPPORTS IN THE PANEL FIELD 2. RCUt�,_,! cr "T'3
anchors where applicable to all connecting joists. PLUMBING NOTES 7116.OSB '3.O.C.EDGE
6d CO'.1MON M1, " 2. SEE NOTES:1,3(BOTH FIELDS} 3. INS(JLnTf:a
6).Double up floor joints under wars that nun parallel to the floor joist and under bathtubs. 1).All wf,•!ter supply,d^!nape and venting to be installed as per N.Y.S.Res!denlio! PLYWOOD f6'O.C.FIELD 4'EDGE ZONE 6d C0,1 f ION ff�6 O.C. 8d CO.. 10! 1� O.C. _
NOTE:2 FOR PANEL FIELD 4. FINAL - C;�iv`
an plans. .'
Floors to hnve ceramic ti!e insta'led shall be verfied for proper toad capacity ur'oss noted Constnecin Cede, GYPSUM Tr O.C.EDGE INTERIOR ZONE 8d COV RON f,6"O.C. Bd COM'.AON(r?12"O.C. SEE NOTE:3 � l
1fJALLFOARD COOLERS tt0"O.C.O.0.FIELD BE COMPLE'
NOTES
2).Verify septic system wl`,h the Engineer for Suffolk County Health Department approval. ALL COj'�STF ill.,!'.'..i. 5`-;>.L.:. tl,•;E_T THE
FLOOR SHEATHING:
7}.Provide Vockfng.'bridg'ng it floor joists at 8"J o.c..Use solid btodcrg in floor joists ___ . _ REQUIREMENTS ur T Hr -")Lc O NEW
under all bearingwalls. 3).If wall studs,plates orjolsts are cutout during tnst<llation for any plumbing related work NAIL NAIL THESE NOTES ARE ONLY TO BE REFERRED TO IF MENTIONED IN SCHEDULE NOTEr,00-NOT PROCEED WITH YORK STATE. NOT F r.QP` ,Si�,LE FOR
JOINT DESCRIPTION NOTES
provide adc+rfuate bracf�g and plates t protect and secure the structure.Verily w;h the QTY. SPACf'YG (� AA � � �`
B).Provide insulation baffles at eave vents between raters.Install drart bixkrcrg as state code and marufao•ture's recommendation for maximum hole size end spacing permitted. STRUCTURAL PANELS 6i O.C.EDGE 1).For wall ahea'fm rto wa!tmin 4 feet of the txsmers,ttme t torsi edge ranee attachment require f�i'�'�NG UNTIL SURVEY DESIGN OR CONST( UNION ERRORS.
8d COMMON7 rHAS BEEN AON LOCATION
PRO_ED.
- needed. HVAC SYSTEM NOTES r OR LESS 1142'0.C.FIELD be used.
9).Unless otherwise noted,an roofs and wars to have a minimum 1i2"thick,4-ply Fir 1).Mechanical subcontactor Is responsible for adheadng to all applicable codes and safety NOTES__ 2).Tabulated 12 Inch o.a nag spacing assumes sheathing attached to stud framing members with
CDX exterior sheathing grade plywood.Plywood to cover over plates and headers. requirements. THESE NOTES ARE ONLY TO BE REFERGPE D TO IF G>0.49.For framing members with 0.42<G<,the nail spacings shall by reduced to6 inches o.c. !
1n).Unless otherwise noted use 314"thick T3G PTS Fir or AdvaM--h plywood subftoor MENTIONED IN SCHEDULE NOTES CNLW. 3 For exterior net sidi. ntvirtzed box na"s shall be permitted to be substituted for common mils.
Z).HVAC subcontractor is to fogy coordinate ail system data and requirements with lire )• Pa 'rg.9= tmc'
adhered with PL400 adhesive and screwed to Poor joists.Finished Poor to be installed i
equ prrermt supplier.
over subfloor as per manufacture's instrur!:errs. 1).Nailing requirements are based on wall efta'hing
3).HVAC subcontractor to provide finel system layout drawing and submit it tothe General na"P.d till en-center at the pa^ef edge.if orate I sheathing U b i •x'�`' . � '�d"
11).Ali bathroom walls to have 12'thfck moisture-res!stant s",ock.Garage wills and Contactor and owner for final review and approval. is nailed 3"on-centpr at the panel erIge to mbliin higher
ceilings an A otrot parts over furnace to have 5t3'thick type-x sheetrock.All of building shear,cenac?t!t's,waiting requirements for ettnudural
to have regular 12"sheetrock.All wills to be t.3ped and finished. ELECTRICAL NOTES: 'members shall be doubled,or alternate comnectors,
such as shear plates,shalt be used to mainttatn load path. -
12).All roof with a pilch less than 4:12 shaq be instn!'ed with an Ica&Water bander or 1).Ai e!ect*Icai to be installed as per N.Y.S.Residential ConstrtcCon Code.
a^proved equal.Flat reels she!l be appl ed with a Fiberglas base)sheet with an EPDM 2).When weq sheathing is corn+ruous over(connected !U t.rw
torch d^wn type rintertaf over. 2).A!1 electrical work shag be approved by a qualu'ed Underwriter, members,the inbula'ed number of na?is shalil be permitted
to bet reduced tol-16d nail per foot �" 4, *`r-r�•'t
13).All sill plates and woof it contact with concrete to be press ire treilted.Sill plates to 3).Install Smoke deteeors and Carbon Monoxide detectors throughout as per section R317
be it l!4d vMh a foam sill gasket and cop-r-tex termite shield or ipproved equal, of N.Y.S.Residential ConF7uuction Code.
cs�
r-
z
CONSTRUCTION DE1-AILS & WIND LOAD PATH CONNECTION DETAILS WIND RESISTANT CONSTRUCTION CONNECTORS a -�
_-. .�.------------- o
CONNECTION LOCATION: PART NUMBER: NOTES: -1 U)
RIDG_E—TO—RAFTERS LSTA24 APPLY TO EACH PAIR OF RAFTERScq
RAFTER—TO—WALL RT20 APPLY TO EACH RAFTER uIS,'., "Q
RAFTER—TO—PLATE RT15 APPLY TO EACH RAFTER
NOTCHED RAFTER USE WITH SPTH4 CONNECTOR o
RAFTER PLATE—TO—WALL STUD SPTH4 APPLY TO EACH WALL STUD -,
RIDGE
RIDGE 2ND. FLOOR :WALL—TO-1ST. FLOOR WALL KLFTA OR MSTA36 APPLY TO EACH WALL STUD
HEADER—TO—JACK STUD LSTA12 APPLY TO EACH JACK STUD
CRIPPLE STUD—TO—HEADER RT3 OR RT7 APPLY TO EACH CRIPPLE STUD
SHEAR WALL HOLDDOWN ANCHOR ADS5 APPLY TO EACH SIDEWALL END
1ST. FLOOR—UNDER—SILL PLATE MSTA36 OR RS16—R WRAP UNDER DOUBLE SILL PLATE
TY
TYPICAL RIDGE TO RAFTER STRAPPING TYPICAL RIDGE BEAM TO RAFTER STRAPPING USE WITH 3" SQUARE WASHERS �
USE THE FOLLOWING OR APPROVED USP METAL CONNECTORS FOR PROPER V0ND RESISTANT CONSTRUCTION. S�
FOLLOW MANUFACTURE'S RECOMENDED INSTALLATION INSTRUCTIONS TO ACHIEVE MAXIMUM UPLIFT LOAD CAPACITY.
a—
RAFTER PROVIDE 1i2"' SPACING - d
BETWEEN THE END STUD ANCHOR BOLT CONNECTION
AND THE 2 OTHER STUDS
RAFTER FOR ALLOWING CONNECT CORNER STUD ANCHOR BOLT CONNECTION FOUNDATION 5�8"DPA.APN,SPAR BOLT •�
SUPPORTING 6�AXIP.�UPA SPACING
HOLDDOWN INSTALLATION TO TRANSFER SHEAR SILL PLATE TO FOUNDATION 1 STORY 72'OC
TOP PLATE FASTEN WITH 2 16d (�PA�r2 SPACE OR FOOUNDATION _
SILL PLATE TO FOUNDATION
TOP PLATE _ c COMMON NAILS @ 6" O.C. CRAWL SPACE OR FOUNDATION) 2 STORIES 35"OC /
V &L BOTTOM PLATE TO FOUNDATION 1_2 STORIES I Sr OC
WALL STl 1D SLAB-ON-GRADE) _ V
WALL STUD SIDEWALL G ENDWALL USE WITH 3x3 SQUARE WASHERS
(USP LBPS58 OR BP583) t
TYPICAL RAFTER TO WALL STUD CONNECTION ALTERNATIVE RAElM TO WALL STUD CONNECTION SHEAR WALL C_0j3 ER CONNECTION t
� Ca
2ND. FLOOR WALL STUD KING STUDS !
2ND. FLOOR PLATE CRIPPLE STUD
SUBFLOOR O
WOOD JOIST RIM BOARD
j: HEADER
BLOCKING 0 WOOD JOIST
1 ST. FLOOR TOP PLATES
JACK STUDS
GIRDER/HEADER
WOOD GIRDER WOOD JOIST 1ST FLOOR WALL STUD
" l�
TYPICAL HEADER CONNECTION
JOIST FRAMING Or/ER WOOD GIRDER JOIST FRAMING FLUSH WITH GIRDER/HEADER
TYP,'CAL MULTI-STORY CONNECTIONS_
1ST. FLOOR WALL STUD �J
1ST. FLOOR PLATE
SUBFLOOR SILL GASKET
WALL STUD 0 WALL STUD RIM BOARD ® TERMITE SHIELD
BOTTOM PLATE - BOTTOM PLATE
BATHTUB SUB FLOOR _ DOUBLE SILL PLATE DBL. SILL PLATES
DOUBLE JOIST DOUBLE JOIST _ (TO OVERLAP JOINTS)
FOUNDATION WALL
' FOUNDATION WALL
r 4 a `+ O
Ao
SILLPLATES TO FOUNDATION ANCHORING_,,® ,
p0UE3LE.J0IST,FOR.,UNDCR A BATNTUB__ DOUBLE JOIST FOR_N4N-BEARING WALLS_ 1ST FLOOR TO FOUNDATION CONNECTIONS_ --