Loading...
HomeMy WebLinkAbout32350-Z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-32672 Date: 10/15/07 THIS CERTIFIES that the building NEW DWELLING Location of Property: 900 SOUND AVE MATTITUCK (HOUSE NO.) (STREET) (HAMLET) County Tax Map No. 473889 Section 120 Block 3 Lot 4 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated . AUGUST 19, 2006 pursuant to which Building Permit No. 32350-Z dated SEPTEMBER 11, 2006 was issued, and conforms to all of the requirements of the applicable provisions of .the law. The occupancy for which this certificate is issued is SINGLE FAMILY DWELLING WITH ATTACHED WOOD DECK AS APPLIED FOR. The certificate is issued to HARBES FARM RIVERHEAD EAST LLC (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL R10-06-0003 10/01/07 ELECTRICAL CERTIFICATE NO. 7369 04/19/07 PLUMBERS CERTIFICATION DATED 07/13/07 BRETT SINCLAIR PLUMBING Au horized Signature Rev. 1/81 . _ Form No-6 �- n TOWN OF SOUTHOLD ,I BUILDING DEPARTME TOWN HALL 765-1802 1-1 , APPLICATION FOR CERTIFICATE OF OCCUPANCY ,� p J' owing: This application must be filled in by typewriter or ink and submitted to the Building ding De partment�-Xeeif o`A A. For new building or new use: ,,XikFrial=survey=af property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. ✓2 final lfrom"lI-ealtif-Dept.of water supply and sewerage-disposal(S-9 form). *pproval o-e ri al iu'stalla ioi fr m.0 cl of'.:kr 1 WerWffters- r Sworn statement from plumberjcertfymg>that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9,1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property,lines,streets,building and unusual natural or topographic features. 2. A properly completed application and a consent to inspect signed by the applicant.If a Certificate of Occupancy Is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C.wee 1. Certificate of Ocouparicy7-New,dvyell' "-$2500,Additions to dwelling$25.00,Alterations to dwelling$25.00, Swimming pool$25.00,Accessory building$25.00,Additions to accessory building$25.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$25.00 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy- Residential$15.00,Commercial$15.00 Date. "1 ` 1 t` 0 7 New Construction: y/ Old or Pre-existing Building: (check one) ,� Location of Property: U6 SO w r4 House No. Street Hamlet Owner or Owners of Property: Ec(i a a.rj Vf- Wd..,b as Suffolk County Tax Map No 1000,Section 12. C) Block aJ Lot 4 Subdivision Filed Map. r Lot: Permit No.3 0���.��Date of Permit. 91 0 Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted:$ d Applicant Signature CATHERINE MESIANO, INC. 12 MILL POND LANE E. MORICHES, NY 11940-1222 C0 _Z_3a6-2a &3)- '9f. F95,1 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 32350 Z Date SEPTEMBER 11, 2006 Permission is hereby granted to: HARBES SOUND AVENUE MATTITUCK,NY 11952 for CONSTRUCTION OF A NEW 4 BEDROOM SINGLE FAMILY DWELLING (MODULAR) AS PER SCHD AND COUNTY HIGHWAY AS APPLIED FOR at premises located at 900 SOUND AVE MATTITUCK County Tax Map No. 473889 Section 120 Block 0003 Lot No. 004 pursuant to application dated AUGUST 19, 2006 and approved by the Building Inspector to expire on MARCH 11 Fee $ 313 .20 Aut or' zed S gnature ORIGINAL Rev. 5/8/02 Nassau Suffolk Electrical Inspections, Inc. 505-C Lincoln 5t • Riverhead;New York 11901 • Tel: 631-813-2890 • Fax: 631-813-2891 Application: 7369 Date:4/19/07 Issued to:Harbs Farms Address 900 Sound Ave Village: Mattituck Introduced By:: Avey Electric inc. License#:2069-ME was examined and approved up to the above date and was in compliance with the NEC New Home 1st Floor Residential® Pool Det Garage Basement 2rtd floor Corry ieraal Hot Tub Addition Switches Receptacles Fixtures. G.F.I. Range Hood Smoke Detectors Fans Dishwasher Washer/Amps Dryer/Amps Oven Carbon Range/Amps Monoxide Furnace oil Gas Heat Zones Whirlpool Bell Transformers Service Meter Amps Phase Motors 1 2'00A OH 1 Other Equipment- Ou.t Res ✓l�ssacU/1u �'/.ectiicaGJ�sf�i�Grp y, 7 This certificate must not be altered in any manner o��gUFFO�,�coG h Z Town Hall,53095 Main Road Wy �� Fax(631)765-9502 P.O..Box 1179 �Ol �a� Telephone(631)765-1802 Southold,New York 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATION Date: -') — l 3 D Building Permit No. 3 2 3 S o - 2- Owner: (Please print) n ,y� Plumber: ► 1 1 �? �- T�' j�`-' — M P e (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. 0 (Plumbers Signature) Sworn to before.me this 3 day of 20 0`4-- pQNL A.GNU- Yak 7k0 _ C�a�issiona�� 'g,��- Notary Public, County , oF so�ryo� i 4;; TOWN OF SOUTHOLD BUILDING DEPT. ---1 ` 765-1802 INSPECTION - -,�s�� [ ] FOUNDATION 1ST [ ] ROUGH PLBG. 4- [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING POINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: . �- l awr e , DATE ��/ �� INSPECTOR �y Of SOpr�olo cOUM`1,� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION I/X FOUNDATION 1ST K ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION l[ FRAMING 4iTRiPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: DATE INSPECTOR 3 5-0 aOF SO(/l��lo courm,��' TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION KFRAIVIING STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: DATE INSPECTOR OF SO�l�olo �L3 S-0 p OQ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION AllFOUNDATION 1ST [ ] ROUGH PLOG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ]-FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION -- - -----REMARKS: DATE INSPECTOR r JAMES J. DEERKOSKI, P.E. 260 Deer Drive Mattituck, N.Y. 11952 (631) 298-7116 Date: December 20, 2006 To: Town of Southold Re: Strapping Inspection Ed Harbes 1181 Sound Ave Mattituck, NY 11952 SCTM# 1000-120-03-04 To Whom It May Concern: This letter certifies that all wind strapping on die.above mentioned project is in tact, and meets all state and local building codes. Any questions please feel free to call. a N y ,�'`• DEFT . c� �0 S cerely J s J. eerkoski P.E. �s `'V JAMES J. DEERKOSKI, P.E. 260 Deer Drive Mattituck,N.Y. 11952 (631) 298-7-146 Date: December 6,2006 DEC To: Town of Southold Building'Dept. Foundation Inspection Ed Harbes 900 Sound Ave Mattituck,NY 11952 SCTM# 1000-120-03-04 Permit# 32350 To Whom It May Concern: A Foundation inspection was preformed at the above-mentioned site, and the footings were excavated to the proper depth and size. They were also installed as per plan and meet all state and local building codes. Any other questions please call. DE MR, incerely s,L F am s J. Deerkoski r FIELD INSPECTION REPORT DATE COMMENTS ro r� FOUNDATION(1ST) s �D , d ------------------------------------ FOUNDATION (2ND) G ROUGH FRAMING& y PLUMBING All Id A INSULATION PER N.Y. y STATE ENERGY CODE c FINAL (.ems ADDITIONAL COMMENT • Q1� � y� 0 � m- 9 r � ' ' P -410. I 4 Clj z ) v H b A YOUNG &YOUNG Telephone 631-727-2303 400 Ostrander Avenue Facsimile 631-727-0144 Riverhead, New York 11901 admin@youngengineering.com HOWARD W YOUNG, Land Surveyor THOMAS C. WOLPERT, Professional Engineer ROBERT C. TAST,Architect RONALD E. PFUHL, Landscape Architect DOUGLAS E.ADAMS, Professional Engineer July 20, 2007 Town of Southold Building Department Town Hall, 54375 Main Road P.O. Box 1179 Southold, New York 11971 RE: HARBES FARM WORKER HOUSING 900 Sound Ave. Mattituck, Town of Southold New York �zS:C-T:N . 'No_: 10 --1-2.0-03-04 Permit # 32350 r. Dear Sir or Madam: In response to a request from Mr. Ed Harbes, I performed a visual non-destructive inspection of the completed improvements at the above project on July 19, 2007. To the best of my knowledge, information and belief, the construction conforms to the submitted drawings and I could not see any hazardous or deleterious construction. All bedrooms have a smoke detector and there is a carbon monoxide detector in the Dining Area which is central to the home. I also understand that your representative requested two (2) copies of the revised deck drawings showing relationship to the house and conforming to the as-built conditions. These are enclosed herein as requested. Very truly yours, Q&q C -k Robert C. Tast RCTodc Encl. cc: Mr. Ed Harbes Planning Engineering Land Surveying Architecture equipment, existing and new, and all parts thereof shall be maintained in a safe and sanitary condition. All device or safeguards which are required by applicable codes or by the Manufactured Home Standards shall be maintained in conformance with the code or standard under which it was installed. The owner or the owner's designated agent shall be responsible for the maintenance of manufactured homes, accessory buildings, structures and their building service equipment. To determine compliance with this subsection, the building official may cause any manufactured home, accessory building or structure to be reinspected. §RAE102.6 Relocation. Manufactured homes which are relocated shall have a <- NY manufactu is a e cer i ying comp iance with app ica Department of NY Housing and Urban Development (HUD) Manufactured Home Construction and NY Safety Standards and a data plate, affixed in the manufacturing facility, NY bearing not less than the following information: NY NY §RAE102.6.1 The statement: "This manufactured home is designed to NY comply with the federal mobile home construction and safety standards in NY force at the time of manufacture. " NY NY §RAE102.6.2 Reference to the structural zone and wind zone for which NY the home is designed. NY NY §RAE102.6.3 Data relative to the heating and insulation zone and NY outdoor design temperature. NY NY EXCEPTION: Mobile homes manufactured befor Jun�nspec need not NY comply with these provisions if they have y an agency NY bfl" or individual acceptable to the code enforcement official to determine NY that they are: NY NY 1. structurally sound; NY NY 2. free of heating and electrical system hazards. NY NY Written documentation signed by the agency or individual performing the NY inspection shall be submitted to the code enforcement official. NY §RAE102 APPLICATION TO EXISTING MANUFACTURED HOMES AND BUILDING SERVICE EQUIPMENT §RAE102.1 General. Manufactured homes and their building service equipment to which additions, alterations or repairs are made shall comply with all the requirements of these provisions for new facilities, except as specifically provided in this section. §RAE102.2 Additions, alterations or repairs. Additions made to a manufactured home shall conform to one of the following: 1. Be certified under the National Manufactured Housing Construction and Safety Standards Act of 1974 (42 U.S.C. §5401, et seq. ) . 2. Be designed and constructed to conform with the applicable provisions of the National Manufactured Housing Construction and Safety Standards Act of 1974 (42 U.S.C. §5401, et seq. ) . 3 . Be designed and constructed in conformance with the new construction NY requirements of this code. NY Additions shall be structurally separated from the manufactured home. EXCEPTION: A structural separation need not be provided when structural calculations are provided to justify the omission of such separation. Alterations or repairs may be made to any manufactured home or to its building service equipment without requiring the existing manufactured home or its building service equipment to comply with all the requirements of these provisions, provided the alteration or repair conforms to that required for new construction, and provided further that no hazard to life, .,:•health or safety will be created by such additions, alterations or repairs. Alterations or repairs to an existing manufactured home which are nonstructural and do not adversely affect any structural member or any part of the building or structure having required fire protection may be made with materials equivalent to those of which the manufactured home structure is constructed. <- EXCEPTION: The installation or replacement of glass shall be required for new installations. §RAE102.3 Existing installations. Building service equipment lawfully in existence at the time of the adoption of the applicable codes may have their use, maintenance or repair continued if the use, maintenance or repair is in accordance with the original design and no hazard to life, health or property has been created by such building service equipment. §RAE102.4 Existing occupancy. Manufactured homes which are in existence at the time of the adoption of these provisions may have their existing use or occupancy continued if such use or occupancy was legal at the time of the adoption of these provisions, provided such continued use is not dangerous to life, health and safety. The use or occupancy of any existing manufactured home shall not be changed unless such change in use or occupancy is made to conform with all NY applicable provisions of this code. Upon any change in use or occupancy, NY the manufactured home shall cease to be classified as such within the intent of these provisions. §RAE102.5 Maintenance. All manufactured homes and their building service 4, APPENDIX RE MANUFACTURED HOUSING USED AS DWELLINGS SRAE101 SCOPE 5RAE101.1 General. These provisions shall be applicable only to a manufactured home used as a single dwelling unit and shall apply to the <- following: 1. Construction, alteration and repair of any foundation system which is necessary to provide for the installation of a manufactured home unit. 2. Construction, installation, addition, alteration, repair or maintenance of the building service equipment which is necessary for connecting manufactured homes to water, fuel, or power supplies and sewage systems. 3 . Alterations, additions, repairs or relocation of existing NY manufactured homes. These provisions shall not be applicable to the design and construction of manufactured homes and shall not be deemed to authorize either modifications or additions to manufactured homes where otherwise prohibited. EXCEPTION: In addition to these provisions, new and replacement manufactured homes to be located in flood hazard areas as established in Table RR301.2 (1) of this code shall meet the applicable requirements of NY §RR327 of the Residential Code of New York State. NY §RAE501 DESIGN §RAE501.1 General. A manufactured home shall be installed on a foundation system which is designed and constructed to sustain, within the stress limitations specified in this code, all loads specified in this code, and NY the installation instructions included within the consumer manual (s) NY provided by the manufacturer. NY EXCEPTION: Where installation instructions are not provided, foundation and anchorage systems which are constructed in accordance with the methods specified in AE600 of these provisions, or applicable provisions NY of the NCSBCS/ANSI A225-1-1994 standards, or which are designed by an NY engineer or architect licensed by the state to practice as such, shall be NY deemed to meet the requirements of this code. NY §RAE501.2 Installation instructions. The installation instructions as NY included in the consumer manual (s) provided by the manufacturer of the NY manufactured home shall be used to determine permissible points of support for vertical loads and points of attachment for anchorage systems used to resist horizontal and uplift forces. Where manufactured homes are relocated, NY and the installation instructions are not available, such points of support NY and attachment shall be determined in accordance with applicable provisions NY of the NCSBCS/ANSI A225-1-1994 standards or by an engineer or architect NY licensed by the state to practice as such. NY , §RAJ202 NY ENERGY EFFICIENCY NY NY §RAJ202.1 Existing installations. Provisions in this code shall not NY require the removal, alteration or abandonment of, or prevent the continued NY use and maintenance of, an existing building envelope, mechanical, service NY water-heating, electrical distribution or illumination system lawfully in NY existence at the time of the adoption of this code. NY NY §RAJ202.2 Additions. Additions shall conform to the provisions of this NY code as they relate to new construction without requiring the unaltered NY portion(s) of the existing system to comply with all of the requirements of NY this code. Additions shall not cause any one of the existing systems to NY become unsafe, hazardous or overloaded. NY NY §RAJ202.3 Historic buildings. The provisions of this code relating to any NY alteration, repair, enlargement, restoration, relocation or moving of NY buildings or structures shall not be mandatory for existing buildings or NY structures that have been specifically determined as historically NY significant by the State or local governing body or listed in the National NY Register of Historic Places, or that have been determined to be eligible NY for listing in the National Register by the State Preservation Officer. NY NY §RAJ202.4 Substantial alterations to existing buildings. This code shall NY only apply to that portion of a building subsystem that is replaced, NY provided that 50 percent or more of such building subsystem is replaced NY within any consecutive 12-month period. NY NY EXCEPTIONS: NY NY 1. Installation of storm windows over existing glazing. NY NY 2. Replacement of glazing in existing sash and frame provided the NY U-factor and solar heat gain coefficient (SHGC) will be equal to or NY lower than before the glass replacement. NY NY 3 . Replacement of a roof membrane where either the roof sheathing or roof NY insulation is below the roof deck. NY NY 4. Replacement of existing fenestration, provided, however, that the NY area of the replacement fenestration does not exceed 50 percent of the NY total fenestration area of an existing building and that the U-factor NY and solar heat gain coefficient (SHGC) will be equal to or lower than NY before the fenestration replacement. NY NY 5. For a subsystem that is being modified or repaired but not replaced, NY provided that such modifications will not result in an increase in NY energy usage. NY NY 6. For the relocation of existing equipment or appliance. NY NY 7. Repairs and/or replacements that are not substantial alterations. NY COUNTY OF SUFFOLK STEVE LEVY �"�.-- _! • - `T. �. SUFFOLK COUNTY EXECUTIVE �U�;-ii QF SOUS''' `r DEPARTMENT OF PUBLIC WORKS GILBERT ANDERSON,P.E. LOUIS CALDERONE CHIEF DEPUTY COMMISSIONER DEPUTY COMMISSIONER September 5,2006 Young&Young 400 Ostrander Avenue Riverhead,NY 11901 Attn:Thomas Wolpert Re: Edward Harbes Sound Avenue,Town of Town of Riverhead SCTM#1000-120-03-04 Dear Mr.Wolpert: Since this proposed development is not adjacent to a County maintained road and subsequently not under our jurisdiction,a permit from this Department is not required. If you have any questions,kindly contact this office at 852-4100. Very truly yours, William Hillman,P.E. Chief Engineer By: —14 P� M.Paul Campag6la Director of Highway Planning&Permits WH:MPC:ln SUFFOLK COUNTY IS AN EQUAL OPPORTUNITY/AFFIRMATIVE ACTION EMPLOYER (631)852-4010 335 YAPHANK AVENUE ■ YAPHANK,N.Y.11980 ■ FAX(631)8524150 YOUNG &YOUNG T Telephone 631-727-2303 '9 400 Ostrander Avenue Facsimile 631-727-0144 SFp 1 4 2006 Riverhead, New York 11901 admin@youngengineering.com HOWARD W YOUNG, Land Surveyor THOMAS C. WOLPERT, Professional Engineer ROBERT C. TAST,Architect RONALD E. PFUHL, Landscape Architect DOUGLAS E.ADAMS, Professional Engineer VIA FAX & REGULAR MAIL September 13, 2006 ATTN: Mr. Damon Rallis Town of Southold Building Department Town Hall, 54375 Main Road P.O. Box 1179 Southold, New York 11971 RE: EDWARD W. HARBES III at Sound.Avenue, T/O Riverhead, New York (05-0541)" Dear Mr': Rallis.' The perimeter enclosure for the above referenced project is to meet all requirements as set forth in the NYS Residential Building Code Section AE503.1. The enclosure shall also.have a minimum insulation rating of R-19 as required by the Town of Southold Building Department. If you have any questions regarding this matter, please contact us. Very .truly yours, Robert A. Fleming RAF/mal Encl. cc: Mr. Ed Harbes Planning Engineering Land Surveying Architecture TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWNaHALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey www. northfork.net/Southold/ PERMIT NO. Check Septic Form N.Y.S.D.E.C. f Trustees Examined ,20 Contact: Approved ,20/_� Mail to: ®,,�y E: Disapproved a/c qC0 0r--1fl-A1J0&-M AJt Q✓NL1_4&0 Ew cr,1= 1140 Phone:_ toil - 70-7 - 0-10 a Expiration ,20 n ---� B g In.sp 91. ` AUG +® � n ' APPLICATION FOR BUILDING PERMIT BUD& nFPT. T �rV r St LITHO, (`I'r'' 2Q0 � Date �u.ve , 20� t't"` INSTRUCTIONS a. Thi��s�a' plrea�i� ,1V`IUST be ompletely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans;ac urat =pjo ' n�to sc e.Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months.Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,'and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions, or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. VJJ- /4 (Signature of applicanQLn4x1e,if a corporation) gDo oSTaA,,JDM ek%j ► aim E A 1 11in 1l (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder A6ewT Name of owner of premises (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: _ House Number, Street Hamlet County Tax Map No. 1000 Section_ l ao Block O3 Lot O L Subdivision Filed Map No. Lot (Name) 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction- a. Existing use and occupancy b. Intended use and occupancy A(721,":vn.To12A1-- LjoeKF2 0 3. Nature of work(check which applicable): New Building Addition Alteration Repair Removal Demolition X Other Work (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars d 4 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front7.3� Rear Q7,`3� Depth Height 13 Number of Stories ©A/E 9. Size of lot: Front 100.o' Rear 100.O De th .1 a'SO' p 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO 13. Will lot be re-graded?YES NO Will excess fill be removed from premises?YES NO. 14. Names of Owner of premises ep A¢ �,. A,,,., mAddress Win. a®x ,sad Phone No. t S I-835-6geV ofouv . w11 %Ccl /V Ir s Name of Architect . �A�r aF , ,Address o, .rAAn+0c2 AW Phone No 63i- 727 - oL c> Name of Contractor �` Address E ' ' `VY " —Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO )< * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO_ C * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTY OF ) `LZamtrcy- A. -V=tem,'VC being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the Ac7L-✓l (Crm?t-a C ,,Agent, ev_point ) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief, and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this—,— day of 20 O Not ublic Signature of Ap t tp 49M151S0 Stb"pdftSIiMCCoullyo Commbslon E�res JuSy.ZA,20_ L , / MANUFACTURING PLANl Date of Manufacture Manufacturers Serial Number and Model Unit on ' e210q0 ^-� ` o,this mobile home should arise please vvntaPt the dealer from whom it was purchased,the manufacturing plant listed below or: Answers to most questions regarding operation,installation, - ` . ' maintenance and uaoign capabilities are' found In the appropriate ooc-tmnocxthe � owner'smaintenance ' This mobile home is desi' n0d to comply with the fedeG8 mobile h00O s_- y standard in force ;t the time of manufacture. ' The factory^installed muuomu Equipment �anu�o�,� �o�amu Equipment �unuommer � uoo . / For heating �^Washer For air cooling N In Clothes Dryer For cooking hi In Dm»wuv»or nomoemmr % Gmbuoeoinponu| Water heater Other . ' .. STRUCTURAL DESIGN BASIS CERTIFICATE , North Middle Middle Zone I / . - South Note:Hawaii and Canal Zone=Zone I UU �-�. � Virgin - ut h Zone loan Zone I North Zone 11 - ' ' DESIGN ROOF LOAD ZONE MAP DESIGN WIND ZONE MAP _-__aoum uopGp -Standard Wind Zone 1sparHorizontal ePapUplift � Middle oopaF Y Hurricane Resistive zonoU uoperHorizontal. 15pSpupNu worth 40PSF __omor PnF __-omu, __PSpnorizoma| __PSrUplift HEATING AND COOLING DESIGN BASIS CERTIFICATE < The above h000nn equipment �m �e capacity to maintain an average 701Fmmpaogm temperature In ou tdoor �2VF. Tv maximize furnace operatingeconomy,and u,conserve ananm' It is recommended that this home uo installed whrg the outdoor win- ter design temperature(erY2%)iu not higher marT:n'p The above Information has been calculated omsummnamaximum wind | i of 15 MPH vu standard atmospheric pressure. The air distribution system of this home is suitable for the In7 uta|boi6nm central air conditioning. Zone I The supply air distribution Installed in this home is sized for . �om�� Home �nnon| Ai, Cvnuiovnmo av=mmo� of up to rated capacity which are certified in accordance ` Zone II - with tappropriate Air Conditioning and Refrigeration|npommStan- dards.When the air circulators cx such air conditioners are rated at o.3 inch water column static pressure o,greater for the cooling air delivered tv the mobile home supply air duct system. DESIGN WINTER CLIMATE ZONE A Information n00000a,y to ou|oulah» cooling loads at mmovu This mobile home has been thermally insulated m locations and orientations)o provided in the special comfort cooling ` conform with the requirements v,the Federal Mobile Information provided with this mobile home. Home Construction and Safety Standards for all Tv determine the required capacity m equipment m cool ahome |vvanuno within climaticavnv |-_----' efficientlyal cooling load(heatgain)calculation is ` zoneu Zone III required.The cooling load is dependent nn the orientation, location . VvFonM^�owPROVIDEDovTxsm«mu RsnwenB� : --the— - - the�—'-Central air conditioners- - operate— -most— ur^u/vmv ma� capacity G*nvToc*LCuuTsaswmoLsHsAramw. / efficiently— — -- provide calculated�cooling �� �"4Each xvm�vn� � closely approximates v*um�xmouwmuowxand 000nN.'..,'.''..' ^u''=-���[~� ^ -con with o American uvv and AirConditioningcmnmoomm�v�m���vnm, .'''...^.'.,'. "" =� � """""u. "='�=""�' - snom v,punuumon��once mo�nmmn ��ommunumvmvfuamvvxx .......'..'''. ^ and«rientation--'-��e�-'----' Fmvm ..................................... ^ x Air ducts In floor..'.......................... Air ducts in ceiling ...........................Air ducts installed ^ � outside the home .......... ^u''=-���[� X Heat transfer area m outside m home from air ducts ^ Inside home ......................... .. Pt' U Outside Home ^Gq F{^�-�1��_ ''''��'�''�' '''�������� - ' ALTERNATE 2 ` / Town Of Southold P.O Box 1179 Southold, NY 11971 * * * RECEIPT * * * Date: 06/19/06 Receipt#: 23886 Transaction(s): Reference Subtotal 1 1 Septic Permit-Construct- Resid. 3606 $10.00 Check#: 23886 Total Paid: $10.00 Name: Young, &Young Surveyors 400 Ostrander Ave Riverhead, NY 11901 Clerk ID: FRAN Internal ID:3606 BUILDING PERMIT EXAMINER CHECKLIST DATE REVIEWED: / /05 APPLICANT: DATE SUBMITTED: / 105 SCTM#DISTRICT: 1,000, SECTION: 120 , BLOCK: 3 , LOT: SUBDIVISION: -- ADDRESSZOL>rJ Pluc;l CITY: ZONING DISTRICT: CONFORMING?AM BUILDING PERMITS.OPEN/EXPIRED: PRE CO: Y OR N-BP -Z/C/0 Z- , INFO BP -Z/ C/0 Z- , INFO BP -Z/C/0 Z- , INFO SINGLE & SEPARATE CERTIFICATION-REQUIRED NOTES: LOTS 40,000SF-100-24.Lot recognition.(CREATED before June 30,1983),UNDERSIZED LOTS FROM JAN.1997 100-25.Merger.(A nonconforming at anytime after 7/1/8. REQ. LOT SIZE: LA)K- ACT. LOT SIZEa 1 ?&' RE .'LOT COV. ACT. LOT COV. REQ.FRONT PROP. FRONT Q SIDE ��-- — ACT. SIDE Q.RE REAR �`y PROP. REAR REQ. 14EIGHT PROP. HEIGHT . yba PROJECT DESCRIPTION: ljego SF-T Sctfb COLM-r-t.rA)p- , Le7me.2 ESTIMATED PROJECT COST: �CI �T/ENGINEER'"T- I-�� WATER FRONT? DESCRIPTION: PANEL # FLOOD ZONE BULKHEAD? DISTANCE? APPROVALS REQUIRED SUFFOLK COUNTY HEAL DEPT ff)or (BED#): ty DTE`(_/ 17/Z PERMIT SEPTIC RECEIPT TOWN E N ST�C CE T FICATIO or N > NEW Y.ORK STATE DEC: PRE-DEC 9/1/75 YES Or O DTE: / /_ PERMIT#; SOUTHOLD TOWN TRUSTEES: YES NO DTE / /_ PERMIT#: TOWN ZONING BOARD APPROVAL: YES No PERMIT#- TOWN PLAN. BOARD APPROVAL: YES O 0 z DTE / / PERMIT#: TOWN HISTORICAL PRE (SPLIA): YES o NEW YORK STATE CODE COMPLIANCE (SEE PAGE 2 : ES r NO NOTES: FEE�TRUCTURE: FOUNDATION: SF FIRST FLOOR: SF 12, SECOND FLOOR: SF nTHER-- ..--SF ------ � (�THFR TOTAL-- -- 6 3. 2 0 TOTAL: SF FEE FEE FEE (j Z. ( SF)- NSF)= SF X $ =$ +$ +$ $ 3. ( SF)- (_ SF)= SF X $ =$ +$ +$ _ $ 2p FINAL TOTAL: $ NEW YORK STATE CODE COMPLIANCE CHECKLIST CLIMATIC/GEOGRAPHIC DESIGN CRITERIA: Ground Snow Load:45 Wind Speed: 120MPH Seismic Design Category:B Weathering: Severe Frost Depth: 36" Termite: M-H Decay: S-M Design Temp: 11 -Ice Shield Underlay:YES Flood Hazards: USE/OCCUPANCY CLASSIFICATION: HEIGHT/FIRE AREA: TYPE OF CONSTRUCTION: DESIGN CRITERIA: ENGINEERED/PRESCRIPTIVE FULL FRAMING DESIGN ELEMENTS: Y/N HEADERS:Y/N WALL STUDS:Y/N GIRDERS s Y/N CEILING JOISTS: Y/N FLOOR JOISTS:Y/N ROOF RAFTERS:Y/N LUMBER SPECIES AND GRADE:Y/N DESIGN LOAD CALCULATIONS: Y/N LIVE:Y/N DEAD:Y/N SNOW:Y/N SEISMIC:Y/N WIND: Y/N WINDOW AND DOOR SCHEDULE: MISSLE TEST REQUIREMENTS: Y/N EGRESS 5.7 S.F.: Y/N LIGHT 8%: Y/N VENT 4%: Y/N NAILING/CONSTRUCTION SCHEDULE: Y/N MEANS OF EGRESS: Y/N PLUMBING RISER DIAGRAM: Y/N LOCATION OF FIRE PROTECTION EQUIPMENT: Y/N TRUSS DESIGN: Y/N _— rERT�IC—ATI9 --. — -- ---..�NERGY—CAL—C—S:_..Y—N--..-- -- ----- -- --- --- -- ------ _. - - _ _ _ -.._.- . TOTAL COMPLIENCE? Y/N (RETURN TO PAGE ONE) ------------------ - R. Young & Young \ \ \ 400 Ostrander Avenue, Riverhead, New York 11901 vg.3 631-727-23039e 'T \� t N Howard W. Young, Land Surveyor .� U)Q �� \ t Thomas C. Wolpert, Professional Engineer <� < ti Robert C. Tast, Architect ' Ronald E. Pfuhl, Landscape Architect xW° Douglas E. Adams, Professional Engineer TO O U Z SOUND ENUE W �.� E .� 3 HEALTH DEPARTMENT USE �C=U° �a a x 575 \ ,� ` SUFFOLIC COUNTY DEPART�ViENTi OF HEALTH SERVICES al 575 x a IDGE OF PAVEMENT N N STONE PAR UTILITY \\ <o KIN& o -0-POLE 583 REAR 6 GAP sET \ PE 'T FOR APPP-OVIeL �'CONSTR�i��'i�ON FOR A s,�o SS°14'50"E 100.00 \ CL1+J FATLY I SI' t i C ONLY 15_ � 50a.01 TO ALDRICH LAN \� s� z � wooD FENCE X ON `I DATE �7 C�� SR-EF N 10-06-M-1 O S mo�E s 111 APPROVED 0 2 � 9 Q. O 11 _ F MAXI AXI B�rilRO g SKAD FENCE N 570G WITMIN15o F o 0 Aband®ri ear®f existing sanitary system must b�g� EXPIRES THREE YEARS FROM DATE OF APPROVAL o _ 1 eorifbimance with department requirement Submit �m=� EXISTING I �AIR 4tte,,d form Vtl tlV M-28o asu proof. zo�� 1 vets E o�Fy � DE L15HED1 �R�R I` mH SURVEYOR'S CERTIFICATION 7t " o ' a • WE HEREBY CERTIFY TO EDWARD HARBES T THIS o %Q m SURVEY WAS PREPARED IN ACCORDANCE WI 10 FENCE PRACTICE FOR LAND SURVEYS ADOPTED O =off o c� O STATE ASSOCIATION OF PROFE55IONAL V Y mom �> Cos HOWARD W. YOUNG, N.Y.S. L.S. NO. 45893 '45a W �~ N 0 om TEST HOLE `� s ��°yy 9 o s s LAI��' " a BY MLDONALD&EOSGIENGE 30 O � DATE: 02/2T/06f2j` a 0.0' �3�' SURVEY FOR :3 9 jG a BRO OL)OAM 1.01 T.H. / ^ \ \ EDP w/1 RD HAMIPE� =LL=z Q� o.00 BROWN °0 V CLAYEY ----------O �, ht• � . At Sound Avenue, Town of SoutholdSAND �Wo O F�. - Suffolk County, New York =�_ 4.0' O Gp. PROPOSED SANITARY s County Tax Map District 1000 Section 120 Block 03 Lot 04 T_°_ N9'L FINE ES BU I LD I N& PERMIT SURVEY o� g s PALE BROWN }Yt " x 585 I"(50 W 100.00' a COARSE Y t O t���11 C« a ° I O SAND .� 1:�. ���a—� i (SW) S33If�83` f,-"s.l.iV-2�HA10 I d-50 \\ now or formerlyW . m May D. Harbes oNs rt.o' L® :Z Wd £Z NAr 90OZ \ ADDED TEST HOLE DATA APR. 5, 2006 zo NOTES (Vacant) MAP PREPARED DEC. 5, 2005 < oa no-p _ NDo�)�rls AREA = 23,676 50. FT. SCALE: I°=40' NU �=MOMENT SET =MONUMENT FOUND Q=5TAKE 5@3A'r3-GKIRbbU �z x T -� • VERTICAL DATUM = N.G.V. DATUM (M.S.L. Ig2Q) JOB NO. 2005-0541 $7 G=CHIMNEY RO=ROOF OVER 5=STOOP GE=CELLAR ENTRANCE 1 DWG. 2005_0224_bp Z3w Sz I I Fogg Young & Young � ;o \ 400 Ostrander Avenue, Riverhead, New York 11901 � E 631-727-2303 flil X Howard W. Young, Land Surveyor o�oo Thomas C. Wolpert, Professional Engineer Robert C. Tast, Architect Ronald E. Pfuhl, Landscape Architect wxao Douglas E. Adams, Professional Engineer o WATER MAIN _ • _ • — — — — — • _ • _ , _ , _ , _ NOTES H SOUND _AV NU W E aa- s I AREA = 25,676 50. FT. as � ED6E OF PAVEMENT N U N UTILITY I STONE PARKIN& 01 POLE a<b�y 100.0011 M 50q.01' TO ALDRICH LANE— METER. g F V �N j O S 2�6F O SURVEYOR'S CERTIFICATION O s \ • WE HEREBY CERTIFY TO EDWARD HARBES THAT THIS 5- �. ExISrrle .SURVEY WAS PREPARED IN ACCORDANCE WITH THE CODE OF -np o \ \ v� PRACTICE FOR LAND SURVEYS ADOPTED BY THE NEW YORK E-zo \ �,� STATE ASSOCIATION OF PROFESSIONAL LAND SURVEYORS. RIA O0 w�O` , O � w -�'x. ' r 3 1 z q HOWARD W. YOUNG, .5. L.S. NO. 458Q3om LAW V O "�� yam 0\\, 5URVEY FOR ° y. EVAARWRIP0% HARMIES ERR ` At Sound Avenue, Town of Southold $o�o Suffolk County, New York m8 653 County Tax Map District 1000 Section 120 Block 05 Lot 04 g16g IBM B F I NAL 5URVEY OV?. 100.00' �_� 555°I"i'SO � a 0 N AU&. 21, 200-7 now or formerly FINAL SURVEY DULY I"I, 200'1 <€3 May �, i�arbes ADDED PROPOSED WATER SERVICE - MAR. I, 200-1 m \ ADDED TEST HOLE DATA APR. 3,200b FAQ Edward I-;arbe5 MAP PREPARED DEC. 5, 2005 4�z= 4yFB a SCALE: 1"=40' � El=MONUMENT SET =MONUMENT FOUND Q=STAKE SET A.STAKE FOUND JOB NO. 200'I-02gb 5 C,=CHIMNEY RO=ROOF OVER 5�=STOOP GE=CELLAR ENTRANCE DWG. 2005_0224_fs M6 ' s= F Young & Young 4 ,who 3�, q f- 4 400 Ostrander Avenue, Riverhead, New York 11901 8 631-727-2303 t t rt I:1' Howard W. Young, Land Surveyor o EE< Thomas C. Wolpert, Professional Engineer F w� Robert C. Tast, Architect xoo tat L�'--" 4��j.��! Ronald E. Pfuhl, Landscape Architect € g ; �.� ���lG�e�,'`,`�� • k � Douglas E. Adams, Professional Engineer ° WATER MA , _ , _ , — � � � E NOTES 5TAvrNUE � Fo EDGE OF PAVEMENT AREA = 25,616 50. FT. =��b i� UTILITY J STONE PARKIN& azt'n POLE 586N88°1450-E i V. 100.00, 1g� 3 WaTER 501.01' TO ALDRICH LANE 0 �}�__ N V• of zd c�S� E o$ o O ; O 'moo \ '- - -roo 9 \ Uip 5URYEYOR'5 CERTIFIOATION &51 6ME - - • WE HEREBY CERTIFY TO EDWARD HARBE5 THAT THIS =t3Z Q Ex'snN& SURVEY WA5 PREPARED IN ACCORDANCE WITH THE CODE OF =o PRACTICE FOR LAND SURVEYS ADOPTED BY THE NEW YORK aBFF \ t I STATE A550CIATION OF PROFF-55IONAL LAND SURVEYORS. F�iM Na C, rl OO _ Yr air;. E3 _ U =;w M, HOWARD W. YOUNG, N.Y.5. L.5. NO.-458g3 LAND . L. � w 0 s - - 5URYE1' FOR ° EVAARD HAR5ES pfl a� At Sound Avenue, Town of Southold JM►.�l'�G �t3U�W DEPARTMENT Ora �SERVICES I ;;;b lU� ; � `LLB o Suffolk County, New York [EFimg APPROVAL OF cros-t RuCTED WORKS FOR N0 ' _ OSE~° ��SINGLE i�•��:r,�l,.�(REbYCJE6�E O �n� � -- County Tax Map District IOOO Section 120 Block 05 Lot 04 OSEz� N.S. Re . E4a.E � .®at® OT0 _ OiWqal a,tid u titer sup i 3dUgc s st ift tocation hus bean Inspe'o" an'4-Sr cerdfisrj by th s or r egencies and toeto�tc 50"W 100.00� � ya�a y,,., BEDROOMS. 585°I"1� m r f sj \� Or formerly AU5. 21, 2001 I f npW FINAL SURVEY JULY 1-7, 200-7 3 ,k �-{grIoP�S ADDED PROPOSED WATER SERVICE MAR. 1200'7 g"b� e J. T-df:�eit, R.E., t1I� \ Mqy D• ' ( ifice of1�ste:^a4Qr Manem7t Edward {.}arbe5 ADDI=D TEST HOLE DATA APR. 3, 2006 $a \ MAP PREPARED DEG. 5, 2005 UZ-1 t. 5GALE: I"=40' E]=MONUMENT SET =MONUMENT FOUND Q=STAKE SET A=STAKE FOUND JOB NO. 200-7-02016 Ego a.K =CHIMNEY RO=ROOF OVER 5-STOOP CE=CELLAR ENTRANCE DWG. 2005-0224_fs C S 5 2'-G" 5 2'-G" I I'-5" 4'-0" I G'-8" G'-10" 13'-72" 4'-0" i G'-8° G'-10° 1 3'-72" —48" x 8" x 4" CONCRETE 9G" x 8" x 4" CONCRETE SLAB TYP. SLAB TYP. --------- I ----------------- 1 ----------------- 8" O CONC. PIER TO REST 1� ---_--- � � ------- ON UNDISTURBED SOIL 2 w (2) 2x w MIN. 3'-0" COVER TYP. i iz id iz co o CJ q �i 1 o 03 q NI N C9 Jilin V NI N =p 1 _ 1p INSULATED PERIMETER LINE OF WALL ABOVE x8 " 1 (2) 2x8 1 X SKIRTING TYP. -----WALLABOVE -----WAWA-- -------------------------------WAWA-- -- ---------------- I 1 24" x 24" CONCRETE � ---FOOTING TYP. I I 1 m 1 1 r----� r r----� r-----i r----� I - i EXISTING W I Ox 11_J 1 1 I I 1 I I I I I L--- J L---_J L----J CL I I ` - I G" x I G" CMU PIER WITH A MIN. ' 1 N CROSS SECTIONAL AREA OF 128 5Q. 1 BEDROOM LIVING ROOM DEN BEDROOM INCHES WITH A 4" SOLID CIVIL) CAP. TYP. / I I I EXISTING W I Ox - - 1 - 1 _ _ _ - 1 1 1 --- --- BATH I � I I I I 1 O I 1 - - - - - - - - - - - o N I N N CL CL CL CL CL I I I I (y) L) 0 EXISTING W I Ox - I _ I I — — — — — I — — 1al — — — , — — — — — , , MECH BATH L----J L----J L----J O HELIX ANCHOR MODEL J No. OT3G4GBP AS KITCHEN �~ N MANUFACTURED BY OLIVER LAU N D RY m 1 TECHNOLOGIES, INC. OR - APPROVED EQUAL BEDROOM DINING ROOM O r-- —� r----� r-----i r----- r— ---1 I EXISTING W I Ox _ _ _ _ 1 �� 1 _ _ _ _ I I CL I I I I I 1 11�_—rJ—I I I I I I I I I — I I I I I I I I I I I I I L____J L----J L----J L----J 2'-3" 12'-0" oo 12'J' 12'-0" 12'-0" 2'-3" I MAX. m MA{. MAX. MAX. CL 1 0 l O O I LWAWA--------------------WAWA-_ �I x8 I i I NOTE: U - ALL EXTERIOR STAIR FRAMING TO BE PRESSURE i INx O II� C) TREATED LUMBER zi N � - EXACT EXTERIOR DOOR LOCATIONS TO BE 2x8 VER,'IFIED IN FIELD PRIOR TO COMMENCING WORK. �1 1 Oil II NI I ---WAWA-- 48" x 8" x 4" CONCRETE SLAB TYP. I 4'-0" (5'-102" 39'-8" 4'_0" 8'-1 02" 5 2'-G" 52'-G" e)f4-)C - FOUNDATION PLAN comPLY T ALL CODES OF SCALE : 1/4 - I -O FLOOR PLAN NEW YORK STARE & OWN CODES SCALE : 1 /4" = 1 '-0" AS REQUIRED AND CONDITIONS OF �PPR ED AS NOTED 2� ,1 35�� SOUTHOLD TOWN PLANNING BOARD DATE: B.P.# 3 DECK JOIST �j ` J REFER TO PLANS FOR SIZE 4 FEE: I✓ BY: �V �—SOUTHO SPACING NOTIFY BUILDING DEPARTMENT AT SOUTHOLD TOWN TRUSTEES 765-1802 8 AM TO 4 PM FOR THE N.Y.S.DEC 14"-15° BALE SEAL ADHESIVE ON FOLLOWING INSPECTIONS: BACK 1. FOUNDATION - TWO REQUIRED Q EXISTING HEADER—,-- "_I,�" NAIL GUIDE LINE SIDE 8 _9 HEADER G- Gd COMMON NAILS @EACH 2. ROUGH O- CONCRETE PLUMBING z SIMPSON C520 EACH SIDE 3/8"-7/100 ZINC COATED REFER TO PLAN FOR SIZE OCCUPANCY OR N 3. INSULATION STEEL,SMOOTH SHANK SIMPSON PB44 • - • • POST BASE 4. FINAL - CONSTRUCTION MUST /�� ROOFING NAILS OR '� !/ USE IS UNLAWFUL EXISTING WOOD POST tIl - CONCRETE FOOTING C) APPROVED EQUAL BE COMPLETE FOR C.O. V 3_p 5 5/8"NOMINAL UNEXPOSED REFER TO PLANS FOR SIZE ALL CONSTRUCTION SHALL MEET THE WITHOUT CERTIFICATE REQUIREMENTS OF THE CODES OF NEW THROUGH BOTH LAYERS YORK DESIGN ORECONSTRUCTON ER FOR 3 D, ERRORS. o OF OCCUPANCY HEADER/POST STRAPPING ROOF SHINGLE NAILING DETAIL POST/JOIST CONNECTION �, 13 SCALE : NONE SCALE : NONE SCALE : NONE CERTIFICATION OF L NAILING & CONNECTIONS RETAIN STOMA WATER RUNOFF Ln 01 REQUIRED. PURSUANT TO SECTION!45-iQ04 o OF THE TOW,,,'CODE. 0 N EXISTING ROOF RAFTER CEILING JOISTS o slMPsoN c520 @ I c"O.C. ALL CONSTRUCTION SHALL 8-8d COMMON NAILS IN EACH AND --- - - MEET THE REQUIREMENTS OF THE PLUMBER CERTIFICATION OF STRAP MIN. EXISTING FLOOR JOISTS EXISTING EXTERIOR WALL STUDS ON LEAD CONTENT BEFORE CODES OF NEW YORK STATE. EXISTING ROOF RAFTERS CERTIFICATE OF OCCUPANCY UNDERWRqERSCERTIFICATE SOLDER USED IN WATER SUPPLY SYSTEM CANNOT J/ SIMPSON SCS� REQUIRED EXCEED 211 WRAPPED AROUND 0 OF 1/o LEAD. DOUBLE E \ SIMPSON H2.5 @ I G"O.C. I G"O.C. O f `/ FLOOD ZOINTE,. ______.. � EXISTING EXTERIOR WALL — PLUMB LNG N COMPLY WITH CHAPTER "46" ( ALL PLUMBING WASTE RIDGE STKAP KAFTER/TOP PLATE STRAPPING FOUNDATION WALL/ FLOOR STRAPPING FLOOD DAMAGE PREVENTION &wgTER L1� =D SOUTHOLD TOWN CODE. TESTING BEF;);=,L ERING SCALE : NONE SCALE : NONE SCALE : NONE ° PROPOSED MODULAR HOME m DRAWING PRFPARFD JUNE 5, 20CG LL- �E of rv�w H AKB ES FARM Young & Young �P yo t 400 Ostrander Avenue, Riverhead, New York 11901 �' �� CHAeZe R�- SCALE: 114" = 1'-0" 631-727-23'03 00 ��` JOB NO.: 2005_054 1 9 AT SOUND AVENUE, TOWN OF SOUTHOLD Howard W. Young, Land Surveyor , �!{ , ,. �, DWG.: ...\ ontract Drawings\A-I .dwg Thomas C. Wolpert, Professional Engineer f�'�� SUFFOLK COUNTY, NEW YORK m Robert C. Tast, Architect Ronald E. Pfuhl, Landscape Architect Douglas E. Adams, Professional Engineer � PLANS AND DETAILS � SrFRfO A4t��'ti '� a 51MP50N C520 @ EACH 51MP50N C520 @ EACH ARCHITECTURAL SHINGLES OVER 30# FELT - PROVIDE ICE � RAFTER TYP. RETROFIT ARCHITECTURAL 5HINGLE5 RAFTER TYP. RETROFIT WATER SHIELD AT PERIMETER ROOF STRAPPING OVER 30# FELT - PROVIDE ICE ROOF STRAPPING VALLEYS WATER SHIELD AT PERIMETER II II II n VALLEYS u u u u 51MP50N H2.5 @ EACH II n u u u u SIMPSON C520 EACH 51DE STUD/RAFTER TYP. u u OF WINDOW HEADER TYP. RETROFIT RAFTER RETROFIT HEADER STRAPPING STRAPPING u u ' r � u u 4" CORNER BOARD (TYP ) SIDING OVER "TYVEK"� i HOUSE WRAP-TYPICAL 4" CORNER BOARD M (TYP.) Ell RAILING STYLE AS EEI SELECTED BY OWNER 5IMF50N C520 @ EACH I SIDING OVER "TYVEK' DECKING AS PER STUD TYP. RETROFIT f HOUSE WRAP-TYPICAL OWNER n FLOOK/WALL STRAPPING n n n n n n n n n n I II II II II II II II II II 5IMP50N C520 @ EACH INSULATED PERIMETER STUD TYP. RETROf IT INSULATED PIRIMETER SKIRT N G TYP FLOOR/WALLL 5TRAPPING f SKIRTING TYP. --------- I I I I I I I I I i I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 I 1 I I I I I I I I I I I I 1 I I I I I I I I I I I 1 1 I I I I 1 I I I I I I I I I I I I I I I I I I I I I I I I I I 1 I I 1 i I I 1 I I I I I I I I I I I 1 I I I L____J L____J L____J L _J L—___J LJ LJ L____J L_ __J L____J L____J L J J 24" x 24" CONCRETE 8" 0 CONC. PIER TO REST 24" x 24" CONCRETE WEST ELEVATION PIERTYP. ON UNDISTURBED SOIL NORTH ELEVATION PIER TYP. MIN. 3'-0" COVER TYP. SCALE : 1 /4" = 1 '-0" S(CALE : 114 = 1 '-0" ARCH ITECTU KAL 5H I NGLE5 OVER 30# FELT- PROVIDE ICE 51MF50N C520 @ EACH ARCHITECTURAL SHINGLES WATER SHIELD AT PERIMETER RAFTER TYP. RETROFIT OVER 30# FELT - PROVIDE ICE VALLEYS ROOF STRAPPING WATER SHIELD AT PERIMETER VALLEYS II II II II 51MP50N C520 & EACH 1 II II II it Itl II u u Liu RAFTER TYP. RETR©FIT u u u u SIMPSON C520 EACH SIDE u u u SIMPSON C520EACI SIDE ROOF STRAPPING OF WINDOW HEADER TYP. OF WINDOW HEP,DER TYP. RETROFIT HEADER STRAPPING RETROFIT HEADER STRAPPING 51MP50N H2.5 @ EACH u r � STUD/RAFTER TYP. ui u r � RETROFIT RAFTER 4" CORNER BOARD (TYP.) SIDING OVER "TYVEK" f STRAPPING fHOUSE WRAP-TYPICAL) (T CORNER BOARD(TYP.) n n n n n n n RAILING STYLE AS 51DING OVER "TYVEK"� II II II 11 II 1 I 11 11 SELECTED BY OWNER HOUSE WRAP-TYPICAL iu 51MP50N C520 @ EACH DECKING AS PER 5IMP50N C520 @ EACH INSULATED PERIMETER STUD TYP. RETROFIT OWNER INSULATED PERIMETER STUD TYP. RETROFIT SKIRTING TYP. FLOOR/WALL STRAPPING SKIRTING TYP. FLOOR/WALL STRAPPING --- ------------- ----I---- I 1 II I I I i I I I I I I I I I I I I I I I I I I I I I II I I I I I I I I I I I I I I I I I I I I I i I I I II I I f I I I I I I 1 I I I I I I I I I I I I I 1 I II I I I I I I I I I I I I I I I I I I I I I I I I LJI LJ L----J L----J L----J L----J LJ J L----J L----J L----J L L____J 24" x 24" CONCRETE 8" 0 CONC. PIER TO REST 24 x 24 CONCRETE WEST ELEVATION FOOTING TY'. ON UNDISTURBED SOIL SOUTH ELEVATION FOOTING TYP, MIN. 3-0 COVER TYP. SCALE : 1 /4" = 1 '-0" SCALE : 1 /4" = 1 '-0" SIMPSON C520 @ EACH RAFTER TYP. RETROFIT ROOF STRAPPING N Q 0 NOTES: z I I I I 1 . CONTRACTOR 51-1ALL VERIFY ALL JOB AND FIELD CONDITIONS, AFFECTING ALL WORK AND OBTAIN ALL MODULAKHOME I I DIMENSIONS TO IN95URE THE PROPER STRENGTH FIT AND LOCATION OF THE WORK. REPORT, IN WRITING, TO THE AI,RCHITECT AND ENGINEER ANY AND ALL CONDITIONS WHICH MAY INTERFERE WITH OR z I 51MP50N H2@ EACH STUD/RAFTER TYP. OTHERWISE AFFECT(, OR PREVENT, THE PROPER EXECUTION AND COMPLETION OF THE WORK. 1 1 1 I RETROFIT RAFTER 2. ALL CON5TKUCT'ION SHALL COMPLY FULLY WITH THE APPLICABLE PROVISIONS OF THE NEW YORK FRAME TIE STRAP AS SHIM AS REQUIRED Tq STRAPPING STATE BUILDING CODE LATEST EDITION AND LOCAL BUILDING DEPARTMENT REQUIREMENTS. MANUFACTURED E LEVEL STRUCTURE TYP OLIVER TECHNOLOGIES ALL PEIR5 3. 501L BEARING ClAPACITY ASSUMED AT I TON5/5F. ALL FOOTINGS SHALL BEAR ON UNDISTURBED INC. OR APPROVED I I I 501L HAVING AT LDA5T THAT CAPACITY. 0 EQUAL EXISTING WI Ox I SIMPSON C520 @EACH Ln L' STUD TYP. RETROFIT 4. ALL CONCRETE OHALL BE STONE CONCRETE AND SHALL DEVELOP A MINIMUM ULTIMATE o FLOOR/WALL STRAPPING COMPRESSIVE 5TRZENGTH AT 28 DAYS OF 3000PS1. n 16" x 16" SOLID INSULATED PERIMETER °o CMU PEIRTYP. SKIRTING TYP. 5. DE51GN OF FOUMIDATION 15 BASED ON ASSUMPTION THAT EXISTING MOBILE HOME STRINGERS CAN 0 O �, SPAN LENGTHS BETWEEN NEW PIERS AS INDICATED. VERIFY WITH HOME MANUFACTURER. GRADE N �` F .. .' FR 5T LINE___ —__ ------- , -------- - - ----------- E o HELIX ANCHOR MODEL 24" x 24" CONCRETE PIER TYP, No. OT3G4GBP AS MANUFACTURED BY OLIVER SECTION TECHNOLOGIES, INC. OR APPROVED EQUAL NOTE: THE FRAME TIE * STRAP TO HAVE AN 0 K' 0 ALLOWABLE WORKING LOAD OF 3, 150 LB5. SCALE 1/4" = I '-0" WITH NO MORE THEN 2% ELONGATION 0 SHALL WITHSTAND A 50% OVER LOAD. (4,750 LB5. TOTAL) .1 4 0- PROPOSED MODULAR HOME 5 DRAWING PREPARED JUNE 5, 20OG LL- Young �c Young ��:��� G�q�`vY0 HARDF-5 FARM t 400 Ostrander Avenue, Riverkead, New York 11901 �gl -ftF `� SCALE: 1/4" = 1'-0" $ 631-727-2 03 er . �~ - s AT SOUND AVENUE, TOWN OF SOUTHOLD JOB NO.: 2005 0541 oC a DWG.: ...\Contract Drawin s\A-2.dw Howard W. Young, Land Surveyor �._.; Thomas C. Wolpert, Professional Engineer ;; ; SUFFOLK COUNTY, NEW YORK 9 g m Robert C. Tast, Architect ``frot Ronald E. Pfuhl, Landsrcape Architect Douglas E. Adams, Profesrsional Engineer 410 SECTIONS AND E LE VAT I O N S -,RED AR& h ry.R.Je 5 2'-G" 40 5' 5" 42'-22 4'-I I" ele 2'-8" 7" 5'-1 I" 6'=0" 6'-0" 6'-0" 5'-10" G'-2" 5'-G" 491-911 01 2'-5" 2'-8" 42'-2-Z' 4'-I I" LINE OF DECK ABOVE (27-2^8-----------( )- ----------------- r --------ter -(27 ------(27 µ C I I I I U ( I I I I 4X4 PRESSURE TREATED POST ON I - DN 4X4 PRESSURE TREATED POST > I I I I I 3'-0" HIGH HANDRAIL GUARD TO I I ! I 8" D!AM, X 8" CONC, FOOTING TO REST COMPLY WITH SECTIONS R3 15, � R3 16 I I I - I OF THE RCNY5. ON UNDISTURBED SOIL MIN. 3'-0" BELOW U G",ADE. PROVIDE 51MPJON TIE SPIKES o TYP. OF ALL LOCATIONS. I WOOD DECK I I I I x I x - (2) 2x8 (2) 2x8 _ _ (2) 2x8 _ _ (2) 2x_,5 N _(2) 2x8_ _ (2) 2x8 _ _(2) 2x8_ i - 524 5Q. fT. _ L 1 L _ —, _ _ _— _ _ _�_ _ I N N — 2x 10 STRINGERS i _ 4X4 POST - �r THRU BOLT U I N N I � I � I 5 1" 2xG ACQ DECKING _ �-4 I 2 a I � Cn INSULATED PERIMETER U I I SKI RTI NGI TYP. N I (2) 2x8 (2) 2x8 _ (2) 2x8 _ (2) 2x8 _(2) 2x8 _ (2) 2x8 _ -(2) 2x8 i Q I � ❑ I I I - LINE OF WALL ABOVE I 24"0 CONCRETE FOOTING i l o .w.... .. ... . �_r��._ . .. . ., - `- TYP. - � I i EXISTING W I Ox i I � � I CL _ I G" x I G" CMU PIER WITH A MIN. CRO`�5 SECTIONAL AREA OF 128 SQ. BEDROOM LIVING ROOM DEN BEDROOM m I I INCHES WITH A 4" SOLID CMU CAP. TYP. l — 1 I I EXISTING W I Ox i I - - - --OIL - - - - - I - - - - I � O `--' --' --' BATH I I � I Is I i - - - - - - - - -- - --- - - - - - - - - - - - - - o 0 N I I N N I I CL CL CL CL CL o i EXISTING W 1 Ox i _ - - - - i ME BATH I I oI I KITCHEN I m i io 5/8"0 ANCHOR BOLT MIN. LAUNDRY 12" EMBEDDMENT ; BEDROOM DINING ROOM O �T I EXi.� iwG VJI Ox ` I CL t 2'-3" 1 2'-0" o� 1 2'-0" 1 2'-0" 1 2'-0" �f 2'-3" i X MAX. m MAX. MAX. MAX. C L n I x U NOTES: NOTE: �i x O I°� o I . THE PURPOSE OF THE LAYOUT OF THESE DRAWINGS ARE TO MAINTAIN AN EXISTING CONDITION. - ALL EXTERIOR STAIR FRAMING TO BE PRE55URf LU N SIN �r 2. ALL PLUMBING TO COMPLY WITH STATE AND LOCAL CODES. TREATED LUMBER 0I 3. ANY AND ALL ELECTRICAL WORK TO BE DONE BY A LICENSED ELECTRICIAN. z - EXACT EXTERIOR DOOR LOCATIONS TO BE a _ 2x8 4. DIMENSIONS HAVE PRECEDENCE OVER SCALE. VERIFIED IN FIELD PRIOR TO COMMENCING WORK. nI - ------- I 5. ALL CONCRETE TO BE 3500 P51. 00 oil------------ G. ALL LUMBER IN CONTACT WITH CONCRETE TO BE PKE55URE TREATED. NI ---- I 7. ALL WORK TO BE COMPLIANCE WITH THE RESIDENTIAL CODE OF NEW YORK STATE. -------- 8" x 8" x 4" CONCRETE 8. THESE PLANS REPRESENT AN EXISTING CONDITION AS BEST COULD BE DETERMINED BY VISUAL INJ�D SLAB TYP. ELEMENTS OF CONSTRUCTION CONCEALED DURING THE INSPECTION ARE INDICATED AS REQUIR~D BY STANDARD CONSTRUCTION PRACTICES. OWNER SHALL UPGRADE AS NECE5SARY. 39'-100, 2" 5' 0" 8'-5" 39'-12 I 51 -011 81 _511 5 2'-G" 5 2'-G" m 3 FOUNDATION PLAN FLOOR PLAN z SCALE : 114" = 1 '-0" - -- >- K��) 0 SCALE : 114" = I '-0" 12 z Z 0 EXISTING HEADER u u SIMPSON C520 EACH SIDE U EXISTING WOOD P05T Ln OI L 0 EXISTING ROOF RAFTER CEILING Ln HEADER/P05T STRAPPING JOISTS REEF JOS IANSFORSIZE 51MP50N C520 @ I G"O.C. SCALE NONE SPACING EXISTING FLOOR J015TS EXISTING EXTERIOR WALL STUDS 8-8d COMMON NAILS IN EACH END 1 4"-1 5" SELF SEAL ADHE51VE ON HURRICANE 1 OF STRAP MIN. BACK10 STRAPPING TIES EXISTING ROOF RAFTERS _12 NAIL GUIDE LINE EVERY OTHER DJ G-I Gd COMMON NAILS @ EACH s \ 8 9 SIDE THRU BOLTS 3/8"-7/100 ZINC COATED i�2X8 TIE EACH LINE OF POST D UBLOE SILL @ N C520 WRAPPED AROUND N = STEEL,SMOOTH SHANK SIMPSON H2.5 @ 16"O.C. 51MP50N PE344 I G"O.C. ROOFING NAILS OR POST BASE to PLAN FOR SIZE TO m JLn APPROVED EQUAL�2 �2 � CONCRETE FOOTING 3'-0 REFER TO PLANS FOR SIZE EXISTING EX o " 5 5!8"NOMINAL UNEXPO D 1fERIbR WALL 4 THROUGH BOTH LAYERS — Q N RIDGE STIRAP ROOF SHINGLE NAILING DETAIL RAFTER/TOF' PLATE STRAPPING P05T/JO15T CONNECTION MU N DATI OfN WALU FLOOR STR.APP1 NG SCALE : NONE SCALE : NONE SCALE : NONE SCALE : NONE SCALE : NONE 0 a_ JULY 16, 2007 PROP05ED MODULAR HOME' NOVEMBER 17, 20OG SEPTEMBER 12, 2000 DRAWING PREPARED JUNE 5, 2000 IL te,r.0_^---r^-,yYoung Yocng ... j H ARB ES EARM -12 400 Ostrander Avenue, Rtiwerhead, New York 11901 `-' ><VI EF�AF,��` SCALE: 1/4" = I'-0" 0 631-7277-2303 - `ply 1 ,s AT SOUND AVENUE, TOWN OF 50UITHOLD JOB NO.: 2005 0541 s DWG.: ...\Cont cp ract Drawin \A-I.dwg Voward IF. Young„ Land Surveyor ' '-' � � SUPFOLr� COUNTY; NFW YOF'KC Thomas C. Wolpert, Pirofessional Engineer .,. ED Robert C. Tait, Architect Y •. Ronald E. Pfuhl, Lacndscape Architect Douglas E. Adams, Professional Engineer a �� _ '� a PLANS AND DETAILS i ``"' ��r'A� v' AMMEND BP# 32350 SIMPSON C520 @ EACH SIMP50N C520 @ EACH ARCHITECTURAL SHINGLES RAFTER TYP. RETROFIT ARCHITECTURAL SHINGLES RAFTER TYP. RETROFIT OVER 30# FELT - PROVIDE ICE WATER SHIELD AT FtRIME�ER� ROOF STRAPPING OVER 30# FELT - PROVIDE ICE ROOF STRAPPING VALLEYS 1,0z" WATER SHIELD AT PERIMETER u II II n VALLEYS Full 51MP50N C520 EACH SIDE STUD/RAFTER TYP. u u u u u u u u 51MP50N H2.5 @ EACH 11 11 OF WINDOW HEADER TYP. RETROFIT RAFTER RETROFIT HEADER STRAPPING STRAPPING t 4" CORNER BOARD u u u u ('YP ) - ��` SIDING OVER 'TYVEK"� 3'-0" HIGH HANDRAIL GUARD TO HOUSE WRAP-TYPICAL / \ 4" CORNER BOARD EM- n COMPLY WITH 5ECTION5 R3 15, R3 ! �1\ (TYP.)OF TI1E RCNYS. RAILING STYLE AS H T.O. HANDRAIL , � SELECTED BY OWNER SIMPSON CS20 @EACH �1151DING OVER TYVEK DECKING AS PERO z DECKING STUD TYP. RETROFIT HOUSE WRAP-TYPICAL���{{{ FLOOR/WALL STRAPPING n n n n OWNER m � IL II II n i i n n n n n T.O. DECK _ PROVIDE SKIRTING AS PIER OWNER I' _ 1 ' ' ' p ' ' II II II - SIMPSON CS20 @EACH INSULATED PERIMETER STUD TYP. RETROFIT INSULATED PERIMETER 4X4 PRESSURE TREATED POST SKIRTING TYP. F R/LOOWALL STRAPPING f SKIRTING TYP. N GRADE 8" DIAM. X 8" CONC. FO(OTING TO REST I i i i i i I I 1 O z_ ON UNDISTURBED SOIL WIN. 3'-0" BELOW I I 1 1 1 1 I I I I I c0 GRADE. PROVIDE 51MP5oON TIE SPIKES B.O. FOOTING LJ LJ LJ L----J L_ j L----J L----J LJ LJ L----J L----J L----J I I I J 24`0 CONCRETE PIER TYP. 4X4 P05T ON 8" CONC. FOOTING TO REST ON UNDISTURBED SOIL EAST ELEVATION 24 0 CONCRETE PIER TYP. SOUTH ELEVATION MIN. 3-0 BELOW GRADE. TYP. OF SCALE 1/4" - 1 '-oil ALL LOCATIONS. SCALE 1/4" = 1 '-0" ARCHITECTURAL SHINGLES OVER 30# FELT - PROVIDE ICE -91MP50N C520 @ EACH ARCHITECTURAL SHINGLES WATER SHIELD AT PERIMETER RAFTER TYP. RETROFIT OVER 30# IF - PROVIDE ICE � VALLEYS ROOF 5 T RAPPING SIMFSON CS20 EACH WATER SHIELD AT PERIMETER� @ VALLEYS RAFTER TYP. RETROFIT n n n n ROOF STRAPPING i u n 1i u u u u u u u u 51MP50N C520 EACH SIDE u u u 51MP50N C520 EACH SIDE 51MP50N H2.5 @ EACH OF WINDOW HEADER TYP. OF WINDOW HEADER TYP. STUD/RAFTER TYP. RETROFIT HEADER STRAPPING RETROFIT RAFTER RETROFIT HEADER STRAPPING STRAPPING SIDING OVER "TYVEK" \\ ell/ \ ` ® �� u 3'-0" HIGH HANDRAIL GUARD TO HOUSE WRAP-TYPICAL 4" CORNER BOARD COMPLY WITH SECTIONS R3 15, R3 16 (TYP.) SIDING OVER "TYVEK"� OF THE RCNYS. 4" CORNER BOARD (TYP.) , HOUSE WRAP-TYPICAL T.O. HANDRAIL RAILING STYLE AS r SELECTED BY OWNER ""` T.O. HANDRAIL I 7111 � DECKING 2X6 DECKING o _z n n n n I I 0z_ i i1 II II II �� T.O. DECK m � PROVIDE SKIRTING AS jj I PER OWNER f ' T.O. DECK 51MP50N C520 @ EACH PROVIDE SKIRTING AS PER OWNERH. fINSULATED PERIMETER STUD TYP. RETROFIT SKIRTING TYP. FLOOR/WALL STRAPPING GRADE GRADE 4X4 PRESSURE TREATED P05T N t\ N GRADE 1 1 i i1 11 11 11 11 11 11 i1 I 1 1 1 I I I 1 8 DIAM. X 8 CONC. FOOTING TO REST i 1 1 1 I I I I I I I I 4X4 PRESSURE TREATED P05T ON ON UNDISTURBED 501L MIN. 3'-0" BELOW c z 8" DIAM. X 8" CONC. FOOTING TO REST 1 1 I I I i I I I I I i GRADE. PROVIDE 51MP50N TIE SPIKES c� 1 1 1 1 I I I I I I 1 1 I I I I I I O z 1 1 I I I I I I I I ON UNDISTURBED SOIL MIN. 3-0 BELOW I I 1 ful rL-� B.O. FOOTING GRADE. PROVIDE SIMP50N TIE SPIKES rL l f'-`1 ILl LJ LJL____J L----J L____J L----J LJ LJ LJ TYP. OF ALL LOCATIONS. LJ LJ LJ LJ LJ L-J LJ LJ L____J B.O. FOOTING 211"0 CONCR��TE PIER TYP. NORTH ELEVATION WEST ELEVATION SIMPSON C520 @EACH STUD TYP. RETROFIT — " 11 — SCALE : I /4�� - I -0 SCALE : I/4 - I -011 FLOOR/WALL STRAPPING 3 51MP50N C520 @ EACH RAFTER TYP. RETROFIT Q ROOF STRAPPING NOTES: Z 3 o I I I 1 . CONTRACTOR SHALL VERIFY ALL JOBANID FIELD CONDITIONS, AFFECTING ALL WORK AND OBTAIN ALL U DIMEN5ION5 TO INSURE THE PROPER5TKENGTH FIT AND LOCATION OF THE WORK. REPORT, IN � 1 I MODUTAR HOME I i WRITING, TO THE ARCHITECT AND ENGINEER ANY AND ALL CONDITIONS WHICH MAY INTERFERE WITH OR p OTHERWISE AFFECT, OR PREVENT, THEPROFER EXECUTION AND COMPLETION OF THE WORK. I I SIMP50N H2@ EACH STUD/RAFTER TYP. 2. ALL CONSTRUCTION SHALL COMPLY FULLY WITH THE APPLICABLE PROVISIONS OF THE NEW YORK 3'-0" HIGH HANDRAIL GUARD TO RETROFIT RAFTER STATE BUILDING CODE LATEST EDITIONAND LOCAL BUILDING DEPARTMENT REQUIREMENTS. COMPLY WITH SECTIONS R31 5, R3 16 F RAME TIE STRAP AS SHIM A5 REQUIRED T STRAPPING OF THE RCNYS. MANUFACTURED BY LEVEL STRUCTURE TYP 3. 501L BEARING CAPACITY ASSUMED AT 11 TONS/SF. ALL FOOTINGS SHALL BEAR ON UNDISTURBED OLIVER TECHNOLOGIES ALL PEIRS SOIL HAVING AT LEAST THAT CAPACITY. T.O. HANDRAIL o INC. OR APPROVED I I DECKING o I EQUAL I EXISTING W I Ox I I 51MP50N C520 @ EACH 4. ALL CONCRETE SHALL BE STONE C011CRETE AND SHALL DEVELOP A MINIMUM ULTIMATE O z O I STUD TYP. RETROFIT COMPRESSIVE STRENGTH AT 28 DAYSOF' 3000P51. PROVIDE SKIRTING AS PER OWNER G I FLOOR/WALL STRAPPING O 16 x 16 SOLID 5. DESIGN OF FOUNDATION IS BASED ON iA55UMPTION THAT EXISTING MOBILE HOME STRINGERS CAN T.O. DECK PERIMETER SPAN LENGTHS BETWEEN NEW PIERS A5 INDICATED. VERIFY WITH HOME MANUFACTURER. 2XG DJ I G" C. (2)2X6 CM PEIRTYP. O 3' SKIRTING TYP. 4X4 PRESSURE TREATED POST Cz GRADE N N GRADE (2)2X8 8" DIAM. X 8" CONC. FOOTING TO REST WITH THRU ON UNDISTURBED SOIL MIN. 3'-0" BELOW o z_ BOLT GRADE. PROVIDE 5IMP50N TIE SPIKES m _ -- L J FR ST LINE ---- B.O. FOOTING m m 8 Cd ANCHOR BOLT MIN. 24 O m " `� 5/ CONCRETE PIER TYP. ! 2" EM5EDDMENTK"'� ,SECTION 0 SECTION NOTE: THE FRAME TIE * STRAP TO HAVE AN SCALE : I/4" = I '-0" o ALLOWABLE WORKING LOAD OF 3,150 LBS. N SCALE : I/4" = I '-O" WITH NO MORE THEN 2% ELONGATION SHALL WITHSTAND A 50% OVER LOAD. (4,750 LB5. TOTAL) 0 JULY 18, 2007 PROPOSED MODULAR HOME NOVEMBER 17, 2000 p, 1~' §._r '.•t"' Y�,"�, SEPTEMBER 12, 2000 E �� • C11 �,� }'?�, DRAWING PREPARED JUNE 5, 2000 Youngr & Young •"` `�j�' �� H ARBES FARM LL 400 Ostrander Avenue, Rivexhead, New York, 1190 f SCALE: I/4" = I'-0" , 631-727—•2303 �`. t',..=4,:F : JOB NO.: 2005_0541 AT SOUND AVENUE, TOWN OF SOUTHIOLD DWG.: \Contract Drawm 5\A-2.dw Howard W. Young, Land Surveyor 1. SUFFOLK COUNTY NEW YORK 9 g Thomas C. iPolpert, Pro1fessional Engineer t - - - ;' " Robert C. Tast , Architect Ronald E. Pfuhl, Lantdscape Architect Douglas E. Adams, Projfessional Engineer �S,rfo'f1 n ,i'`� SECTIONS AND ELEVATIONS ( ✓ EPED AMMEND BP# 32350