Loading...
HomeMy WebLinkAbout33025-Z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-32671 Date: 10/15/07 THIS CERTIFIES that the building ADDITION Location of Property: 61341 MAIN RD SOUTHOLD (HOUSE NO.) (STREET) (HAMLET) County Tax Map No. 473889 Section 56 Block 1 Lot 4.3 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated MAY 3, 2007 pursuant to which Building Permit No. 33025-Z dated MAY 10, 2007 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ADDITION & ALTERATION TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR. The certificate is issued to MICHAEL P & CLAIRE L GLEW (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A ELECTRICAL CERTIFICATE NO. 07-6368 10/03/07 PLUMBERS CERTIFICATION DATED 09/28/07 CUTCHOGUE EAST PLUMBING Auth rized Signature Rev. 1/81 • R ��...e.�'-...• .� .. .ter ".1,�� y Form No.6 Y TOWN OF SOUTHOLD y 1 BUILDING DEPARTMENT TOWN HALL LG 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY 1a_L This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in-system contains less than 2/10 of 1% lead, 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied; the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$25.00;Additions to dwelling$25.00, Alterations to dwelling$25.00, Swimming pool $25.00, Accessory building$25.00, Additions to accessory building$25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 Date. 10 I tZl v - New Construction: Old or Pre-existing Building: (check one) Location of Property: (o t 341 V,O,GC --Q zS Isn a' �10 1 House No. Street Hamlet Owner or Owners of Property: CJ la T C— R M ( CAOIJ2�( Suffolk County Tax Map No 1 0, ection Block Lot 4 3 Subdivision s I c4r� p C a 22 Filed Ma Lot: Permit No. J� Date of Permit. t' Q Applicant:M1 C a)40 C� Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: t� (check one) Fee Submitted: $ Applicant Signature ��325 U3�(� w 7 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 33025 Z Date MAY 10 , 2007 Permission is hereby granted to: MICHAEL P & CLAIRE L GLEW PO BOX 1950 SOUTHOLD,NY 11971 for ADDITION & ALTERATION TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR at premises located at 61341 MAIN RD SOUTHOLD County Tax Map No. 473889 Section 056 Block 0001 Lot No. 004 . 003 pursuant to application dated MAY 3 , 2007 and approved by the Building Inspector to expire on NOVEMBER 10, 2008 . Fee $ 338 .40 Authorized Signature ORIGINAL Rev. 5/8/02 ,;°\,1.��tif�•�•a S�ffMJ./Aiaa SS,fdM1AA'a fi6�4M.fJ/'raa Sr�Zf�.fJJI'a r��f111f,G'fa. r��1. �'. Sr a ,•fifJifGEj�•. T .. • w '•Ai '` .. • !Ks wow 'ma's' '�`i. `�..,,. .r '�.:,.� ' ;,r �P((�q, yl y-V '-i,. i, y � � �,�,•\\ .; 1, /�j :..�� �//r �>:` , �.;. t /r.c� �� , a/jai•�a�\\ �� ra r�5,::fk•� /�� \ ��!.:� i a `s �• €' Electrical Inspectors Inc. Certificate Number: 07-6368 , ry; 308 East Meadow Avenue 1� ..f•, %7 Municipality: Southold,Town Of Z East Meadow,NY 11554 Office:(516)794-0400(631)396-7474 Inspector: 125 r'ik"s.sz Fax:(516)794-5854 Issue Date: 10/3/2007 �a ;. �.•< Website:www.electricalinspectors.com Email:info@electricalinspeetors.com �1'<;,$J• Mail To: Property Address: JJW Electric John J.Wade Glew g�T\ PO Box 306 61341 Main Road y` �\ Aqueboque,NY 11931 Southold,NY 1 971 License#: 4664-ME t;L� s r' ELECTRICAL APPRO VAL9ERTIFICA TE \r , AREAS LISTED BELOW ARE APPR E Y INSPECTION r (fC AND FOUND TO BE IN COMPLIANCE WI ATIONAL ELECTRIC CODE y,5j No visual defects were found for the electrical inspection pro ded.No obvi unsatisfactory conditions were found in the areas herein below only. Residential Inspection t;F Basement:Storage Room / \\ First Floor:Bathroom,Bedroom,Family Roo3 ,'Po Roor 14-Duplex Receptacles,2-GFI Receptacles - Amp gle eceptacle,1-20Amp Appliance Receptacle,4-Smoke Detectors,1- 1:!+ �:;_t• CO Alarm,18-Switches,3-Recessed Fixt e,6-Incand sce t Fixtures,5-Wall Sconces, 1-Paddle Fan, 1-8 Ft. Trac Light,1- �f i Exhaust Fan. Rough 8123107 Final1012107 :r O eW 3 i Not valid unless signed by an / f authorized EII Agent 5„ Philip F.Goehring Richard M.Bivone President Chief Electrical Inspector as y ytr. • w S w :a"s_ / .ri�.li \ e v ri I.L ..., .YEN. Y' Y:. t A T 5 4t✓ I. 'YA;yy yR. 7k`•K yF:AR ::. 1. ELECTRICAL INSPECTORS,INC. is not responsible for the existing conditions at the subject premises. 2. ELECTRICAL INSPECTORS,INC.is not responsible for corrections, upgrading or replacement,of,existing electrical violations at the subject premises. Any corrective work shall be solely the responsibility of the property owner. ELECTRICAL INSPECTORS,INC.DOES NOT WARRANTY OR UNDERWRITE THE ELECTRICAL CONDITIONS AT THE PREMISES. 3. ELECTRICAL INSPECTORS,INC.only recognizes the National Electric Code,the Building Codes of New York State all volumes and Local Municipal Codes,as Authorized by The Department of State Codes Division, via Village,Town or City Board Resolution. 4. AN ELECTRICAL SURVEY consists of a visual examination of the premises ONLY:Electrical Inspectors Inc. will comply with the requirements of NFPA 73, latest edition Chapter 1,Section 1-1, 1-2.If violations exist, a Notice of Violation (NOV)will be issued requiring correction by a licensed electrical contractor. After the violation has been corrected,a re-inspection will be conducted and if approved a certificate shall be issued. 5. A SURVEY CERTIFICATE does not examine the actual wiring or devices unless all walls are opened and wires and devices are exposed prior to the survey being conducted. 6. A CERTIFICATE is non-transferable. 7. AN ELECTRICAL INSPECTION consists of an examination of wiring and installations during the rough stages of construction. After completion of the construction a final inspection will be conducted at which time a certificate will be issued provided no violation exist. In the event no inspection is requested during the rough stages of construction ELECTRICAL INSPECTORS,INC.will perform a CLOSED WALL SURVEY that consists of a visual inspection of the wiring and installations only. Since access is limited,ELECTRICAL INSPECTORS,INC.shall bear no responsibility for any defects or violations at the premises. 8. ELECTRICAL INSPECTORS,INC. shall not be responsible to remove any walls in order to conduct an electrical inspection. 9. ELECTRICAL INSPECTORS,INC.will only release information,certificates and reports to the applicant after payment for services rendered have been paid in full. 10. ELECTRICAL INSPECTORS,INC.assumes no liability for the results of its inspections. 11. The agreement may not be changed orally. �j' SF P 2 Q 20-O DEPT. T jW\ QF,�IUTHOLD Fax(51€) 765-1 E23 Town Hall, 53095 Main Road � � Telephone(515) 765-1802 P. 0. Box 1179 SoulhokJ, New YOM t 197? OFFICE OF THE BUILDING iNSPECTO `OWN OF SOUTHOL } :,D)A;TK L2 <3 o 7 Building Permit No. 330z J Owner- // '(Ile — CIS f2 eL-f (please print) P I umber: . �� (please print) I certify that. the solder used in the water supply sysrem contains less than /10 of it lead. gall ~ � s (� umbers Signature} �. WISIAN J,NAGY Notary Public state of New York No.4896735 Sworn to be fors me his Qualffled In Suffolk County /� '10mmlf7siOn Fxoirsa May 20.//— --..--s.2— day of �7 Notary Public, County �OF SO(/l�, hod ono o�ycou N TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSU ATION [ ] FRAMING / STRAPPING [ INAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: DATE INSPECTOR .11 OF SOUryo TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ]:�NSULLATION H PL13G. [ ] FOUNDATION 2ND [ [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: b DATE INSPECTOR _ '�`� -:33 OF SO(/lyo`o �yC0UNP1,� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECT'ON [ ] FOUNDATION 1ST [ ROUGH PLBG. [ ;;RO DATION 2ND [ ] INSULATION AMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION rl- REMARKS: DATE INSPECTOR �o�apF SUUlyolo 0 N Q TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION FRAMING STRAPPING' [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: DATE INSPECTOR q SO(/ couun,��' TOWN OFiSOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: C. DATE INSPECTOR q SO(/l�o TOWN OF SOUTHOLD BUILDING DEPT. 765-1602 INSPECTION [ J FOUNDATION 1ST [ ] ROUGH PLBG. K FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ J FIRE RESISTANT PENETRATION Y REMARKS: DATE INSPECTOR FIELD INSPECTION REPORT DATE I COMMENTS ro FOUNDATION(1ST) q� y ------------------------------------- i FOUNDATION(2ND) z o Y lJ ROUGH FRAMING& PLUMBING 4 ' x INSULATION PER N.Y. — y STATE ENERGY CODE V ' O CD J FINAL ADDITIONAL COMMENTS O z m a 1 � O z E�- �_y C t�J �d y TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL _ ZQJ, Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 _ Survey www. northfork.net/Southold/ PERMIT NO. _ 930zs-g� Check Septic Form N.Y.S.D.E.C. Trustees Examined dio ,20_0 Z_ Contact: Approved /p,20ja;L_ Mail to: Disapproved a/c Phone: Expiration 20 08' Building Inspector APPLICATION FOR BUILDING PERMIT Date , 20 INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months.Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name,if a corporation) (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder Name of owner of premises IIJ�( C�J�S i �t ( < W (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on wh' h proposed work will be done: ea3�r z� House Number Street '`'•_'"'"I. Hamlet County Tax Map N . 1000 Section- J" :: Block;, Lot r Subdivision Lot p... . (Name) 2. State existing use and occupancy of premises and i tended use a d occupancy of proppsed construction: a. Existing use and occupancy nN S t b. Intended use and occupancy s 3. Nature of work (check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work /�� (Description) 4. Estimated Cost 0751 V u U Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear 5 Depth oZ Height Number of Stories Dimensions of same structure with alterations or additions: Front 7-3 Rear 7 S Depth Height Number of Stories / 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front 2 Z(0 Rear �-Z-0 Depth _ 10. Date of Purchase Name of Former Owner Gc' 11. Zone or use district in which premises are situated jo 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO X 13. Will lot be re-graded? YES NO Will excess fill be removed from premises? YES NO 14. Names of Owner of premiscUO lKeP LWCR '` �&ss Poe)& Iq SDPhone No. 7(a1S`(1?.)Q Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO X * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTY OF� C `a I.rc L being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the ChQ (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this 3,-o( day of 20V CL- Nota Public UppF.KONVALSKI Signature of Applicant � PUNOSTATE OF N�1�.'!��`S 52-4624771 lSStot4 VW S NOVV A 30,E TOWN OF SOUTHOLD PROPERTY RECORD CARD r OWNER STREET VILLAGE DIST. SUB. LOT ACR. REMARKS 17"T TYPE OF BLD. PROP. C SS �.- 4 /LAND IMP. TOTAL DATE ."y 400 Z to - Hinoc to (o N i e l`6 v C / poeQ 3 { q I S 0 4,?Sr7 G1e •.�Llt�; , 1 �' E.1 rtnr .' J i` I FRONTAGE ON WATER TILLABLE z FRONTAGE ON ROAD WOODLAND DEPTH MEADOWLAND BULKHEAD HOUSE/LOT 00 TOTAL P ^ h ■■■■■■ ■■■■■v� ■M■■ ■■■■■■■� ■■■■■ ■■■■ ■■■MEMO■I■■■■■■■■■■■ i- Foundation Basement 1� Ext. Walls Interior Finish Fire Place Rooms 1st Floor Driveway ENERGY CODE CALCULATIONS CHAPTER.5 SECTION 501 Detached One and Two Family Design Criteria 5750 Degree Days (For Non-Electric Meat) Zone 11B For: /"l,c hit C�G�r Per: elfc�j 11T S o y i a l N y '" 7l Dated: 3 , u7 SUBSYSTEMS DESIGN CODE DESIGN CODE "U" "U" UA UA Exterior Walls U. /1 ? ? 0.14 ��. 2- Ceiling Roof 0 , v 3 0.031 -v Floor Over Unheated Space ��2 p 0.05 2 s o Heated Slab On Grade 6.5 Unheated Slab On Grade 4.5 Basement Wall 0.1 Crawl Space Wall 0.06 NOTES: Construction shall comply with 502.1.1 moisture control and 502.1.4 air leakage Building Envelope Systems to meet requirements of Section 501 The mechanical systems and equipment including: HVAC Equipment, HVAC Systems,Duct Systems, Ventilation Systems and Insulation of Piping Systems to meet requirements of'Section 503 Service Water Heating Systems &Equipment to meet requirements of Section 504 Electrical&Lighting Systems &Equipment to meet requirements of Section 505 34 F te", s To the best of my knowledge, :rye belief, & professional judgement, . °'e °3225� ' s f these plans are in compliance �gFESSI��'�`�O with-the code. 07 Erosion, Sedimentation and Storm-water Run-off Control Plan ASSESSMENT FORM Yes. No. EXEMPTIONS:. A. Does this project meet the.minimum standards for classification as an Agricultural Project. . ,Note: If you.answered.Yes.to any.of the.above,a.Storm-water,Grading,Drainage.&Erosion.Control.Plan is,not required. ------------------------------------------------------------------- ACTIONS.REQUIRING THE.SUBMISSION OF A STORM-WATER, GRADING.DRAINAGE &EROSION. CONTROL.PLAN.CERTIFIED.BY A DESIGN.PROFESSIONAL.IN.THE.STATE.OF NEW.YORK.. Item Number:. (A Check Mark (J).for each question is,required for complete.application). Yes: No. 1. Will this.project retain all Storm-Water Run-off generated on Site? (This.will include.all run-off created by site.clearing and/or construction activities.as well as.all y Site.Improvements and the.permanent creation of impervious.surfaces.) / 2.. Will this,project require any land filling, grading or excavation where.there.is,a change to the natural existing grade.involving more than 200 cubic yards.of material within any.parcel? 3.. Will this.application require.land disturbing activities.encompassing an area, of five.thousand(5,000).square feet of ground surface or more? ❑ 4. Is.there.a Natural Water course.running through the.site or is this.project within One hundred(100).feet of wetlands or a beach? a 5. Will there be.site preparation on slopes which exceed fifteen(15).feet of vertical rise.to. One.hundred(100)feet of horizontal distance? ❑ 6.. Will driveways,.parking areas or other impervious.surfaces.direct Storm-Water.Run-off. into.and/or in the.direction of a Town Right-of-Way? 7. Will this application require the placement of material,removal of vegetation and/or the. construction of any item within the Town Right-of-Way.or road shoulder area? (This.item.does.not include.the.installation of driveway aprons.) 8. Will there be site preparation within the one hundred(100)year floodplain of any.watercourse? Note: If.any.answer to questions one.through.eight is answered.with.a check mark in the.Box,a Storm-water,Grading, Drainage.&Erosion.Control.Plan is.required and must be submitted for review prior to.issuance.of any building.permit. ------------------------------------------------------------------- STATE OF NEW YORK, —COUNTY OF. .................. ........ ss That I, ..... 1• . ••••••••.•..••.............................................being duly sworn, deposes and says that he/she is the applicant for Permit, (Name of individual signing Document) And that He/She is the ...........................Qo _e_r(' ........................................................................................................................ ontractor,Agent,Corporate Officer,etc.) Owner and/or representative of the Owners,and is duly authorized to perform or have performed.the said work and to make and file this application;that all statements contained in this application are true to the best of his knowledge and belier;and that the work sill be performed in the manner set forth in the application filed herewith. Sworn to before me this; .......5�...............day of....41�12' .. ...................... 20..4 . - L Notary Public: ✓ ........... . KOWALS . . ....5. ................. . LINpA F.• ............. AR IVFOBLIC,STATEOF N• !?+`:^''\ - (Signature of Applicant) NO 52-4624771 QUALIFIED IN SUFFOLK COLIN T Y COMMISSION EXPIRES NOV 30,2616 ENERGY CODE CALCULATIONS CHAPTERS SECTION 501 Detached One and Two Family Design Criteria 5750 Degree Days (For Non-Electric Heat) Zone 11B For: l 1,r-4{ Per: SOU4 0 AlN� Dated: 3LI- u7 SUBSYSTEM AREA CCU" CODE DESIGN CODE "U" "U" UA UA Exterior Walls U. 11 0.14 (o,f• 2 J Ceiling Roof o, o 3 0.031 L�• .3( �-.v 7 Floor Over Unheated Space 12 6 p � 0.05 Z v 25, Heated Slab On Grade 6.5 Unheated Slab On Grade 4.5 Basement Wall 0.1 Crawl Space Wall 0.06 ' / t7G • / � 7, 6,3 NOTES: // Construction shall comply with 502.1.1 moisture control and 502.1.4 air leakage Building Envelope Systems to meet requirements of Section 501 The mechanical systems and equipment including: HVAC Equipment,HVAC Systems,Duct Systems,Ventilation Systems and Insulation of Piping Systems to meet requirements of Section 503 Service Water Heating Systems &Equipment to meet requirements of Section 504 � ^ Electrical&Lighting Systems &Equipment to meet requirements of Section 505 r To the best of my knowledge, , belief, & professional judgement, . ��,� 032254 , ;`' these plans are in compliance with-the code. �1410 .7 O ; A Ib a Al 314, it 73 100 xlwt- �� f�Elt.Q.sfo,�,uo.9.ey � �, �s,�4oloVe Eo U GMJ 7�20�fiQ SUFFGL CUi�]TY DEPAIiTl�iivNT GF IEALTFf SERVICES APPROVAL OF C©NSS-aREcTr-,I)wo%:C,.pox.1 � •X, ;IUL 2 1 f99 S.Re3:No. (� ` `�i�_S� 6$ .c LAnro LE d!sposa!and vM-ar ssppty faeflities tt:i3ti�•a.^�i,r:l�v� dcetl v� �`y cer I'd by t'f.1S 7Ej a Var. or otxz::$Ci,Clwp End found to r:� /• ce Satii.`•aav:GCy F'OR c F ifen A.Costa,P.E.,Chief Office o.Water ra±d Was cwater Management f /4�� '4 3696 -- Gad JJ "�"z._._5Z�'S3'✓o"K'�^� ��cYa�Fi�a.���.rCo•�o�rric���s +F-�_._.si 7'Zo'zo•'rvio�9.5 A101 r-f:5SE =: 11EGE5d T2�4 "it9iz'�A �, L�wG /�✓G9W� to�.�r.�_.�r T�..o,�u.�i�oE,r-l�ivr��y y,�. . te,r�✓�.sice�vey�yi��✓�a,�J��s��>',eice.C��e.�.y .?ELREL Aoc/C• ��• .4yryc�vy W-GE�s/.9rvl�rvs�ri' O.,vr�•✓.�,vave✓i�/yam ,�,pyy yE,�a, vivo .cey�rb e ��69 v[erz,Aw i�i9y8 P.ee✓»�a��Ory/�or�.rr��r�Y�aar�xv� ./ yi REV. L 5/28/07 Floor joist changed direction and changed to WI 40 9 1/2 16 OC. Omit footings and column. _ « It i I � • NEyrY �Ir 2 LVL a ki 032254-1 OFESS% 'A i l -2' 1 cv I o +h"i on- 40 9 '/z" 16" OC - ` o • I � � - + -•+ —_..—..._ —.___.. �_-� __+ _T.�__—__.� i — — — — — — — — - — -- ♦ — — — — — — — — I .�C•]Ft�rtu d �'---�`' -t`rrdirc_ t- - IN 1-7 - rU-- 1-117-71 tt _-----. —-- '_ - APPROVED er `t 1 DRAM QY t / _.... --- DATE ..3 3 Z of LYr.T b� ��e1 Oct ..x PLUMBER CERTI Fh A°,T PLUMBING ON LEAD CONTENT E,-_,f I E ALL PLUMBING WASTE CERTIFICATE OF Q;CCU: &WATER LINES NEED SOLDER USED IN WA T E 3 TESTING BEFORE COVERING SUPPLY SYSTEV CArv' V� T EXCEED 2110 OF 1% LE 1. —� CERTIFICATION OF NAILING & CONNECTIONS REQUIRED. 67 j ALL CONSTRUCTION SHj LL - MEET THE REQUIREMENTS F THE _ CODES.OF NEW YORK STATE USE IS UNLAWFUL TTfl WITHOUT CERTIFICATE OF OCCUPANCY NaER+'VRITERSCERTIFICATE REQUIRED Arr, ROVED i"i" to �� -- V _ DATE: �-%f� E.+ .# �..r� - - -- _ - -- FEE:✓J ��_ lA --- ` �— '" w ` "�� u. PT�T AT — - 765 102 "'` FA FOP THE f r,'„ K, 1.�FG 1"dE TiOti J REQLAJ U'-+'fJ `, w FOURE" NCRETE Ft. �` 032254-1 1 2. ROUGH - FRAN'!':G & PLUIJ°ING ., ���� I I 3. INSULATION �a'C v- e � ^TION MUST E,,a10 � I , 4. FINAL - CO°:�.�T�'KI '-� BE CO "(ALE� ,R C.O. I \ ALL CONS T RUCT iUi J SHALL MEET THE L� 6 i ` REQUIREMENTS OF THE CODES OF NEW • r• — — — — — — — — — — — — __ _-. _ _ �, ._ '�---�"`� YORK STATE. NOT RESPONSIBLE FOR CONSTRUCTION DESIGN OR ERRORS. � RETAIN STORM V'JATE^ 'R✓'0-7e PURSUANT TO SECTIV . OF THE TOWN CODE. ' SCALE:— 4 - APPROVED BY. _ DRAWN BY �Icr _ DRAWING NUMBER w�t�awt wurnMsr No.1e5A•1ex:4 w A � �v w rr J'°��,• `f 1 � - I'toaFFJS 'A .......... EDE I — ---- - — —i-� 'F--}--, SCAL . = -APPROVED BY �._._..__. _ DRAWN — DATE ------ t / DRAWING NUMBER sf wo. saw-teX24 � A IZXtNYLQI'ON AnVAMMr nwomm H38 nN E)NIMV1i0 Vd0 Ag 03AOHddV e1- - 31VOS -�I b1�~ N—�,;o►a i%i o '' a ad_c'?L 7r)ll —_-----7 "`��--�-�a o r Z oeClll� 'S _ C�a t � va- •�ti�,.4j _ ,�,,�nr�,�•a�2�a I-r y 'z • -4 C f .. -ap. - x • _ fff • ' Via_-T_;S�— S IT 0LU , lz ti iI , ki 03225 _ - •!S ( f i ,' � u _A'1'(Oh� r _ _..._ t' (r1��R 7kTl.--�a►'T2��C� - - SCALE "� •' " " "APPROVED BY/ DRANK BY DATE .-3�7. 3 I o1 l2YfeT b'i'Ti°7 3IL� o'l _._.._._.__.__ -- DRAW NO NUMB R _ Manama NO.ISSA-1SX24 r-.z " �- 1s1h ►_rG1r�-__ - LA V.- - 41 - i - LLI - - - ;., y2,ZSji A Z ! — - Co f C�32254� u5f-Fo WsT_ U rJ Fr IRT¢-i-�, A-T-k c a T� 'I -� :Z .:- i `'Z,• pr«'w.E t --- To MATY� � � 'tkyIc.•'ac 136131ZoorA i ii F /hI�1,L�_ Rebid �/tMlt_Y �2ae..� f rj,srf i ! ,I Stpinfrt_ l ' i -Lill �I � I�, _Rtgi::��R-�"T'_T".�Fhc� Z�.tsuc.�.a,-�o�! ��'•c-�� _ ( I�( �j , , ,_I�.. - ,L. lir , �I .1 R Yz - Ll U tl � ,g Zs.��x_ro--_I to• O�- - ��P f'r�Y*�r.—sty►-�.t\', t LVL ZX�=Y�L Q_LJ�Furth r _ SICI SEI . - .: ' i 21P Cot_u�+�5 I F4, rW Csx j' Un1tf.°lti�-r� f3A. Scu�rrtT � ►',t :;Food►� _ ' 11 _ i I I i I I N i SO-Lc Its SCALE. '- �.'� APPROVED BY [DRAWN BYTE l n I DATE: 3 15 O"7-._.3 DRAWING NUMBER g rwnialut v�rf�sr No.ISSA-IOX24 GENERAL CONSTRUCTION NOTES GENERAL FRAMING NOTES 1.The information on this set of construction documents is to relate basic design 1.All walls,2x4 and 2x6,to be stud grade or better 16"o/c. All other framing material NAILING SCHEDULE intent and framing details. They are intended as a construction aid,not a substitute to be#2 douglas fir or better. for generally accepted good building practice and compliance with current New York TABLE 3.1. INCLUDING 3.3 AND 3.9 state building codes. The general contractor is responsible for providing standard 2.All wood framing in contact with concrete or masonry to be pressure treated. 1995 SBC HIGH WIND EDITION WOOD FRAME CONSTRUCTION MANUAL construction details and procedures to ensure a professionally finished,structurally JOINT DESCRIPTION NAIL QUALITY NAIL SPACING sound,and weatherproof completed product. 3.Provide double floor joists under all walls parallel to floor joist span direction unless otherwise specified. R O O F FRAMING i� I RAFTER TO TOP PLATE TOE NAILED 8'-0• WALL: 3-8d PER RAFTER O 2.General Contractor to coordinate all sub contractors,scheduling of work,and 10'-0" WALL: 4-8 d PER RAFTER Interaction between trades. 4.Provide x-bracing or solid blocking at a maximum of 8'-0"o/c for all dimensional CEILING JOIST TO TOP PLATE TOE NAILED 8'-0• w A L L: 3-8 d PER JOIST 1,_ 10'-0" WALL: 4-8d PER JOIST Q lumber floor joists. I , i CEILING JOIST TO PARALLEL RAFTER FACE NAILED SEE TABLE 3.7 EACH LAP � AL (I � 3.The general contractor is responsible for ensuring that all work and construction 1- CEILING JOIST LAPS OVER PARTITIONS FACE NAILED SEE TABLE 3.7 EACH LAP meets or exceeds current federal,state,and local codes,ordinances and regulations, 5.Floor construction:Y4"tongue and groove plywood subfloor. Finished material to be COLLAR TIE TO RAFTER FACE NAILED S E E TABLE 3.4 PER TIE ' , r etc. These codes are to be considered as art of the specifications for this building applied over subfloor. Glue and screw I BLOCKING TO RAFTER TOE NAILED 2-8 d EACH END b I I I P P 9 PP plywood decking to floor joists. I i and should be adhered to even if they are invariance with the plan. RIM BOARD TO RAFTER END NAILED 2-18 d EACH E N 0 ,�.-I, 6.All Window and door headers to be minimum(2)2x10 unless otherwise specified. WALL FRAMING I r 4.Dimensions shall take precedent over scale drawings(do not scale drawings). All interior headers to be(2)2x10 unless otherwise specified. TOP PLATE TO TOP PLATE FACE NAILED 2-18d • PER FOOT TOP PLATES AT INTERSECTIONS FACE NAILED 4-18d JOINTS - EACH SIDE STUD TO STUD FACE NAILED 2-18d 24. O/C ti LL1 5.The designer has not been engaged for construction supervision and assumes no 7.Provide full solid blocking Under all bearing walls. HEADER TO HEADER FACE NAILED 18 d 16' O/C ALONG EDGES I �`r responsibility for construction coordinating with these plans,nor responsibility for TOP OR BOTTOM PLATE TO STUD END NAILED 2-18 d PER 2X4 STUD 11 3-16d PER 2X8 STUD c_I ) I+"-� (►��� construction means,methods,techniques,sequences,or procedures,or for safety 8.All beams to have adequate bearing at each end or as specified. 4-10 d PER 2X8 STUD precautions and programs in connection with the work. There are no warranties for a BOTTOM PLATE TO FLOOR JOIST. , specific use expressed or implied in the use of these plans. 9.All flush beam and joist intersections to have galvanized hangers. B A N D JO IS T, END JOIST. OR BLOCKING FACE NAILED 2-18 d • - PER FOOT 6.Refer to floor plans,exterior elevations,and Window schedule for types and sizes of 10.Typical exterior walls and roof to be sheathed With'A"exterior grade plywood or FLOOR FRAMING windows. All Windows to be Andersen high erformance quality or JO IS T TO SILL, TOP PLATE, O R GIRDER TOE N A IL E 0 4-8 d PER JOIST g p q ty approved equal. 7/16"OSB plywood,group 1,APA rated. Plywood to span over all plates and BRIDGING TO JOIST TOE NAILED 2-8 d EACH END ' I headers. BLOCKING TO JOIST TOE NAILED 2-8d EACH END i 7.Door and window headers to align Unless otherwise noted. BLOCKING TO SILL OR TOP PLATE TOE NAILED 3-18 d EACH BLOCK 11.Provide insulation baffles at eave vents between rafters. LEDGER STRIP TO BEAM FACE NAILED 3-18 d EACH JOIST JOIST ON LEDGER TO BEAM TOE NAILED 3-8d PER JOIST �'-- 8.General contractor is to ensure that masonry and prefabricated fireplace BAND JOIST TO JOIST END NAILED 3-18 d PEP, JOIST construction meets or exceeds all manufacturer's specifications and applicable codes. 12.Exterior flashing to be correctly installed at all connections between roofs,walls, BAND JOIST TO SILL OR TOP PLATE TOE NAILED 2-1 8d PER FOOT chimneys,projections,and penetrations as required by approved construction ROOF SHEATHING 9.General Contractor to consult and coordinate with the owner and the plans for all practices. STRUCTURAL PANELS 4'P E R IM E TE R EDGE ZONE-- 16" O/C - 8" AT PANEL built In items such as bookcases,shelving,pantry.Closets,etc. EDGES AND AT INTERMEDIATE SUPPORTS IN THE ' 13.General contractor to provide adequate attic ventilation and roof vents. e d PANEL FIELD 10.Provide hardwired smoke detectors,with battery backup,On all floors and in each INTER 10 R ZONE - 18. O/C - 8' A T PANEL EDGES AND 12' 8d AT INTERMEDIATE SUPPORTS IN THE PANEL FIELD `- + I bedroom,verify with local code requirements as per Section R317,New York State 14.Provide appropriate soffit ventilation at overhangs. FOR ROOF SHEATHING WITHIN 4'-0" OF THE PERIMETER EDGE OF THE ROOF. INCLUDING 4'-0- ON EACH SIDE OF THE ROOF PEAK, THE 4'-0- Residential Construction Code. Install carbon monoxide detectors as per code. GENERAL PLUMBING NOTES PERIMETER EDGE ZONE ATTACHMENT R E O U IR E M E N TS SHALL BE USED. CEILING SHEATHING GENERAL FOUNDATION NOTES 1.Plumbing subcontractor to be responsible for adhering to all applicable code and GYPSUM WALLBOARD 5 d COOLERS 7' EDGE 1 10' FIELD 1.General contractor to review plans,elevations,and details to determine intended safety requirements. WALL SHEATHING STRUCTURAL PANELS 8 d 4'E D G E ZONE - 18. O/C .6- AT PANEL EDGES AND 12' heights of finished floor(s)above typical grade. 2.If wall plates Or joists are cut during the Installation Of plumbing fixtures Or AT INTERMEDIATE SUPPORTS IN THE PANEL FIELD provide bracing to be framing back together. 8 d INTERIOR ZONE - 18" O/C - 8' AT PANEL EDGES AND 12' 2.All footings to rest on undisturbed soil. equipmentP g g 09 A T INTERMEDIATE SUPPORTS IN THE PANEL FIELD FIBERBOARD PANELS 7/18' 8d 3" EDGE / 8' FIELD GENERAL HVAC SYSTEM NOTES 2 513 2' 8 d 3" EDGE 16' FIELD 3.Provide W expansion joint material between all concrete slabs and abutting GYPSUM WALLBOARD 5 d COOLERS 7" EDGE 1 10' FIELD 8d 4'EDGE ZONE - 16' OIC - 8" AT PANEL EDGES AND 12" concrete or masonry walls occurring in exterior or unheated interior areas. 1.Mechanical subcontractor is responsible for adhering to all applicable codes and HARDBOARD AT INTERMEDIATE SUPPORTS IN THE PANEL FIELD safety requirements. 4.Concrete on 4"sand or gravel fill minimum,with 6x6-10/10 wire mesh reinforcing. T��.7 CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA Interior slabs to be placed on 6 mil. stabilized polyethylene vapor barrier. 2.HVAC subcontractor to fully coordinate all system data and requirements with the, 1AS8CHC �V11�D�1CN1111�OFR�1lE _ equipment supplier. WEATHERING SEVERE 5.Provide crawl space ventilation per local code requirements. M STFR.X.' M MAN116L FROST LINE DEPTH 3'-0" 3.HVAC subcontractor to provide final system layout drawing and submit it to generral RAF MSPAam v ac TERMITE MODERATE TO HEAVY 6.General contractor to Install cop-r-tex(or copper)sheet metal termite shields contractor,owner,and equipment supplier for final review and approval. DECAY SLIGHT TO MODERATE between all wood surfaces that are exposed to concrete or masonry surfaces. R07 PI ROW SPA WINTER DESIGN TEMP. 11 7.Dampproof exterior of foundation with a bituminous coating as per code and soil NEW CODE 1 ICE SHIELD UNDER- AS PER MANUFACTURER'S conditions. GENERAL WIND PROTECTION CONNECTION NOTES1 11 LAYMENT REQUIRED SPECIFICATIONS /STATE CODE Adapted from Standard for Hurricane Resistant Residential Construction;SSTD 10-99 41 11 FLOOD HAZARDS and 1995 SBC High Wind Edition Wood Frame Construction ra GENERAL FLOOR PLAN NOTES Fasteners and Connectors for Wood Frame Construction 71 1.Dimensions shall take precedent over scale drawings(do not scale drawings). 1.A continuous load path between footings,foundations wails,floors,studs and roolf 9t13 4 SOUTHOLD BUILDING DEPARTMENT OUTERIA framing shall be provided. 12 1 OCCUPANCY CLASSIFICATION S 1 0 •r- r ,�•, <.' ,; , 2.All interior walls to be covered with W gypsum board with metal comer reinforcing. USE Tape,float,and sand(3 coats). 2.Approved connectors,anchors and other fastening devices not included in the 2 HEIGHT r s_ �i _ 15't�r �1 r T + Standard Building Code,Table 2306.1 shall be installed in accordance with TABLE 3.4 3.Walls common to garage and house to have a layer of 5/8",fire rated gypsum board manufacturer's recommendations. 1995 SBC HIGH WIND EDITION WOOD FIRE AREA(sf) y FRAME CONSTRUCTION MANUAL 3 TYPE OF CONSTRUCTION Vf rrzn .� at garage side with 5'-0"return on adjacent walls and ceiling. Manufactured lumber RAFTER SPACING 16"O/C 4 DESIGN CRITERIA '�+2.c,��P i P� +Is- ��Slc-r 1 Iqs' FI 14{' 'J t ti u requires 2 layers of 5/8",fire rated gypsum board. 3.Metal plates,connectors,screws,bolts,and nails exposed directly to the weather or 120 mph FASTEST W INDSPEED 5 FRAMING ELEMENTS subject to salt corrosion in costal areas,shall be stainless steel or hot dipped E c `* •.� P+�c 4.All bath and toilet area walls and ceilings adjacent to wet areas to have water galvanized. ROOF ROOF NUMBER 6 DESIGN LOAD'CALCULATIONS -7 resistant gypsum board,or wall file set on wonderboard or equal. PITCH SPAN (ft) OF NAILS 7 WINDOW AND DOOR SCHEDULE ph-. 4.Where windows and doors interrupt wood structural panel sheathing and siding, 4:12 12 3 8 LOAD PATH ,{. T r r'r DESIGN LOAD CALCULATIONS framing anchors or connectors shall be provided at the top and bottom of cripple 16 4 9 NAILING SCHEDULE 'A- studs,header studs,and at least one stud at each side of opening. 20 5 10 EGRESS s(_d. MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS Ibsf 24 28 6 11 PLUMBING RISER DIAGRAM EXTERIOR BALCONIES 60 5.Ridge straps shall be attached to each pair of opposing rafters except where collar 32 8 12 FIRE PROTECTION N DECKS 401 ties of 1 x6 or 2x4 lumber is located in upper third of attic space and attach to each pair ATTICS WITHOUT STORAGE 301 of rafters. 36 1 13 TRUSS DESIGN DRAWINGS o �,,v s Fi �•�+^_� N ATTICS WITH STORAGE 40 6.Uplift connectors shall be provided at each rafter bearing. 5.12 12 3 16 a 14 ENERGY CALCULATIONS ROOMS OTHER THAN SLEEPING ROOMS 40 20 4 SLEEPING ROOMS 30 7.Floor to floor hold-downs to be provided every 48,and every 16"within 4'of exterrior 24 5 comers. 28 6 CRITERIA FOR CALCULATION OF DEAD LOAD 32 7 .�-�_ * r a ACTUAL WEIGHTS MATERIALS REFERENCED TO A.I.A. 8.Sill Plate to Foundation Anchorage: Sill plate shall be anchored to the foundatiorn 36 7 8:12 12 3 y `- �y S� ARCHITECTURAL GRAPHIC STANDARDS with anchor bolts having a min.bolt diameter of 5/8"and 3"x 3"x 1/8"washers. A r �0 SNOW minimum of one anchor bolt shall be provided within 6 to 12 inches of each end of 16 20 4 each plate. Anchor bolts shall have a minimum embedment of 7 inches in concrete) GROUND SNOW LOAD 45 lbs. 24 5 masonry foundations. Anchor bolts shall be located within 12 inches of comers and at spacing not exceeding 4 feet on center. 32 s SEISMIC DESIGN CATEGORY g 36 7 � jf'.'"=,• �s' l 7:12-12:12 12 2 �°.,R S1�J�xO WIND THESE NOTES ARE GENERAL CONSTRUCITON NOTES. THEY ARE NOT 16 3 OF 4 •- W IN D SPEED 120 m h SPECIFICALLY WRITTEN FOR THIS PLAN. THEY ARE TO BE CONSIDERED AS D EXPOSURE CATEGORY g GENERAL GUIDELINES ONLY AND SHOULD BE DISCUSSED WITH YOUR Y8 5 I� b GENERAL CONTRACTOR BEFORE CONSTRUCTION BEGINS. 32 6 36 61 00 -.0 •t IL STRUCTURAL WOOD PANELS FOR WIND-BORNE DEBRIS PROTECTION FOR WALL OPENING PROTECTION ROOF MPH 3-SECONDw,ND GUSTS WINDOW AND DOOR SCHEDULE (MAXIMUM MEAN ROOF HEIGHT:35) ' I I MULTIPLE SECTION ASSEMBLY: 1/4" —• _°ar ' • , r • : tT `'�i THICK BOLTS @ 2'OC ="t+ �,a.)„� �t�H� + .rr " . . � � + `, • — " :: 1 , .«.:.t .• p s+� — Y �.. �` a — ,.•, t 101 ,y O - - Z H 3 � < < F- ALL WINDOWS TO BE ANDERSEN HIGH PERFORMANCE OR APPROVED EQUAL A U A I4 11w NOTES CALCULATIONS FOR WINDOWS BASED UPON EXPOSURE B MUST HAVE DP UPGRADE KIT. COEFFICIENT 1.0 WITH 120 mph BASIC WIND SPEED. AS PER E MEETS NY STATE EGRESS REQUIREMENTS f AlL TABLE R 301.2 (2) NEW YORK STATE BUILDING CODE. FOR HABITABLE SPACE. CUSTOM GRILLES —SEE ELEVATIONS U 1 ALL NARROLiNE WINDOWS MUST USE: -3 j ` � .,. � 1/2" HEIGHT SILL STOP (OR STOOL)AND THE ADDITION,OF A 1/2" X 3/4" DP UPGRADE SILL STOP. (SILL STOPS TOTAL A 1-1/4" J HEIGHT AND REQUIRE THE INSTALLATION OF A SPECIAL SASH LIFT INCLUDED WITH DP UPGRADE SILL STOP KIT.) Pq N SHUTTER ASSEMBLY ALL UNrrS MUST MEET OR EXCEED THE MINIMUM DESIGN PRESSURE REQUIRED, ANY MULLED UNITS MUST MEET OR EXCEED '1.5 TIMES THE DESIGN PRESSURE REQUIRED AND MUST TRANSFER LOADS TO THE ROUGH OPENING SUBSTRATE. ALL EXTERIOR N.T.S. GLAZING MUST MEET ASTM E 1996 TEST REQUIREMENTS AS PER NEW YORK STATE RESIDENTIAL CONSTRUCTION CODE. FOR PANEL SPANS: 0 <4'-0"WIDE SPAN REFER TO SECTION R 1609.1.4 FOR ALTERNATIVE OPENING PROTECTION. i TABLE 1609.1.4 23/32"APA SPAN-RATED 48/24 SHEATHING GRADE PLYWOOD (OVERLAP AROUND OPENINGS 4") USE AC GRADE W/2 COATS EXTERIOR PAINT 2 SIDES,4 EDGES. LABEL ACCORDING TO LOCATION. ASSEMBLY: ATTACHING STRUCTURAL PANEL: FASTEN TO BUILDING w/#8x3" (w/WASHERS) GALVINIZED OR STAINLESS STEEL WOOD SCREW @ 16" O.C. OR BETTER ALTERNATIVE FASTNER FOR SHUTTER TO BUILDING: #10 TEE NUTS ATTACHED TO BLDG. w/#10x 1 Y" (W/WASHERS) MACHINE BOLT @ 12" O.C. WHERE SCREWS ATTACH TO MASONRY OR MASONRY STUCCO, THEY SHALL BE ATTACHED I UTILIZING VIBRATION RESISTANT ANCHORS HAIVING A MINIMUM WITHDRAWL CAPACITY OF 490 lbs. ��►'� SHUTTER ASSEMBLY N.T.S. " FOR PANEL SPANS: 4.-0., OR WIDER SPAN I SPECIFICATIONS AND ASSEMBLY IDENTICAL TO 0 <4'-0" SPAN. (—ir rt— NOTE ADDITIONS: Z, 1'IL 2x4 STRONG-BACKS @ 24"OC _ ASSEMBLY: /+Pv2•��n SYS'f�w REASSEMBLE PLYWOOD TO 2x4'S: # 10x3" (w/WASHERS) GALVINIZED OR STAINLESS STEEL WOOD SCREW @ 12" O.C. ALTERNATIVE FOR OPENING PROTECTION WOOD STRUCTURAL PANELS Wmi A MINIMUM THICKNESS OF 7/16"AND MAXIMUM PANEL SPAN OF 8'-0" SHALL BE PERMITTED FOR OPENING PROTECTION IN ON AND TWO STORY BUILDINGS. PANELS 'SHALL BE PRECUT TO COVER GLAZED OPENINGS WITH ATTACHMENT HARDWARE PROVIDED. (REFER TO SECTION 1609.1.4 AND 1609.6.5 AND TABLE 1609.1.4) TABLE 1609.1.4 =� �� WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS �I <. �:, 4f �i + FASTENER SPACING(INCHES) t( 4 jLLJ PANEL SPAN< 74O"<PANEL 4.O"<PANEL 6'-0"c PANEL`` FASTENER TYPE z-cr SPAN<4'4r SPAN<6'-0" SPAN<8'-0" 03225' ' 2 1/2" #6 WOOD SCREWS 16 16 12 9 2 1/2" #8 WOOD SCREWS 16 16 1 16 12 A.THIS TABLE IS BASED ON A MAXIMUM WIND SPEED(3 SECOND GUST)OF 130 MPH AND MEAN ROOF %( p HEIGHT E ERS OR LESS F 1 U M E) INO D I AORAM B. FASTENERS SHALL BE INSTALLED AT OPPOSING ENDS OF THE WOOD STRUCTURAL PANEL. ll.� ii��l JI.�J C. WHERE SCREWS ARE ATTACHED TO MASONRY OR MASONRY/STUCCO,THEY SHALL BE ATTACHED UTILIZING VIBRATION RESISTANT ANCHORS HAVING A MINIMUM WM-(DRAWL CAPACITY OF 490 LBS. O Z F— = J W IZ RIDGE RAFTER _ i w USP RS250 AT 21 Q Q uil - o h c m A RAFTER/RIDGE/RAFTERwmtar RAFTER KING STUDS L r J RIDGE RAFTER STUD o p RAFTER USP RT16 OR(2)RT7--- --- - a HEADER TOP PLATE TOP PLATE USP RS24TMU USP RT3 J USP RT20 USP RS250 AT 180 Y USP LS O WALL STUD WALL STUD USP RS250 AT 12' CONNECTION USP PRODUCT NUMBERJ j JACK STUDS WITH CT*RAFTER/RIDGE/RAFTER W CT• RS250 21" _ C IN r RAFTER/RIDGE/RAFTER WITHOUT CT RS250 21"+LSSH179 'Flo B RAFTER/PLATE/STUD R120 -' RAFTER/PLATE RT16 or(2)RT7 PLATE/STUD RS250 1W Al RAFTER/RIDGE/RAFTERwma B RAFTER/PLATE/STUD B RAFTIER/PLATE PLATE/STUD c Hr--ADER/sT�D RTC ---- -- -- -__--- ----- -- C HEADER/STUD HEADERMACK ----- -----------------.- --- —_ -...__ HEADERMACK STUD RS250 121 --� D FLOOR TO FLOOR KLFTA or RS250 36• E STUD✓PLATE.ISILL RS250 3T STUD✓PLATE RS250 16• PLATE/SILL MPSF F ANCHOR BOLTS STB16 G POST ANCHOR FOR DECKS PAU SERIES POST ANCHOR FOR COVERED PORCHES CBE SERIES •DO OR 2X4-16-O/C COLLAR 71ES MIN. POST USP CBE P.C.FOOTING 2ND.FLOOR WALL STUD 2ND.FLOOR WALL STUD--e I< 1ST.FLOOR WALL STUD 1ST.FLOOR WALL STUD 2ND.FLOOR PLATE 2ND.FLOOR PLATE SUBFLOORG POST ANCHOR FOR COVERED PORCHES SUBFLOOR - --- - - - ----- — ------ - --- 1ST.FLOOR PLATE 1ST.FLOOR PLATE- RIM BOARD RIM BOARD SUBFLOOR SUBFLOOR USP KLFTA USP RS250 AT 36" USP RS250 AT 36" USP RS250 AT 16" ..: 1ST.FLOOR TOP PLATES RIM BOARD RIM BOARD 1ST.FLOOR TOP PLATES DOUBLE SILL PLATE DOUBLE SILL PLATE POST USP MP6F 1 ST FLOOR WALL STUD 1ST FLOOR WALL STUD • • ' rx ` FOUNDATION WALL FOUNDATION WALL • �i ' � •r USP PAU 032254-1 • P.C.FOOTING o06 FLOOR TO FLOOR E STUDJPLATEISILL __ E A PLATE/SILLG NCHORSFORDECKs STUDlPLTE _ _ POST A --- - ..._ - -- _ _ - -_ _ _._ ©0 LL a Lu (7 a