Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
32596-z
FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY NO: Z-32688 Date: 10/23/07 THIS CERTIFIES that the building ACCESSORY GARAGE Location of Property: 6955 SKUNK LA CUTCHOGUE (HOUSE NO.) (STREET) (HAMLET) County Tax Map No. 473889 Section 104 Block 4 Lot 33.2 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated DECEMBER 18, 2006 pursuant to which Building Permit No. 32596-Z dated DECEMBER 26, 2006 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is UNHEATED ACCESSORY GARAGE IN THE REQUIRED REAR YARD AS APPLIED FOR. The certificate is issued to ART & LAURETTA BAUER (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A ELECTRICAL CERTIFICATE NO. 115748C 04/30/07 PLUMBERS CERTIFICATION DATED N/A r Au orized Signature Rev. 1/81 Forth No, 6 \v I� TOWN OF SOUTHOLD / ` BUILDING DEPARTMENT TOWN HALL F �r�UTHO 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features, 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied; the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy -New dwelling$25.00,Additions to dwelling$25.00, Alterations to dwelling$25.00, Swimming pool $25.00, Accessory building$25.00, Additions to accessory building$25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 Date. \0\\c Ad"1 New Construction: Old or Pre-existing Building: (check one) Location of Property: G q cJ C-5 LigAi F c i tC& uez House No. Street Hamlet Owner or Owners of Property: P T A L>a U2e#A _R A U F2 Suffolk County Tax Map No 1000, Section 16 y Block Lot 33 -2- Subdivision Filed Map. Lot: Permit No.3,a 9(P T Date of Permit. Applicant: -71 p u�5 Health Dept. Approval: Underwriters Approval:N�'J Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ Applicant Signature FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 32596 Z Date DECEMBER 26, 2006 Permission is hereby granted to: A & L BAUER 21205 SO HARBOR RD SOUTHOLD,NY 11971 for UNHEATED ACCESSORY GARAGE IN THE REQUIRED REAR YARD AS APPLIED FOR at premises located at 6955 SKUNK LA CUTCHOGUE County Tax Map No. 473889 Section 104 Block 0004 Lot No. 033 . 002 pursuant to application dated DECEMBER 18, 2006 and approved by the Building Inspector to expire on JUNE 26, 2008 . Fee $ 169 . 80 Authorized Signature ORIGINAL Rev. 5/8/02 Electrical Ins ection Certi icate ' y Issue Date Electrical Inspection Service,Inc. Application% ` 4/30/07 375 Dunton Avenue 115748C ' 1»<=s East Patchogue,New York 11772 (631)286-6642 _r,,•��sl? Issued To: Mr. Art Bauer Street: 6955 Skunk Lane; ' Village: Cutchogue Zip: 11935 Town: Southold - Section: Block: Lot: Contractor,:bduble6061e Electrtc'Inc. 1Lrrc.# 3913-E _ ;j : 4 Was examined and found to be in compliance with the National Electrical Code. � w�=�`- ❑ Commercial ❑ NV Defects ❑ Pool ❑ 1st Floor Indoor ❑ Hot Tub ❑ ❑ Basement ~f © Residential X❑ Det Garage ❑ Attic ❑ 2nd Floor ❑ Outdoor ❑ Addition ❑ Survey 4 = Switches Receptacles Fbrtures GFl Heaters A/C Fans 6 9 2 .-parr Dishwasher Washer/Amps Dryer/Amps Oven RangelAmps Microwaves ti Fumace Oil Gas Circulators Smoke Detector Bell Transformer • Meter Amps Phase UG(OH Jacuzzi Television CO Detector ? -r Bldg. Permit: 32596 Other Equipment _ " 1-Subpanel -Garage Door Opener Recept. y Hugo S. rdi ,: >� President �1 �£ Rough Inspection: �ti> Inspector. ;a Final Inspection: 04/25/2007s ✓' Inspector. John McMahon III f : This certificate must not be altered in any manner. Inspectors may be identified by their credentials. �? %rl�}i o !{}# .#�IN q.i�#1# a 1#7l1?v,r/F#1 v{;t#{iY1.x .{}�{##A t .�Ik .3i}#{{I�+f '��f M 14 '�. { ;.i.l�l�{f {,�• !j# :.a + scj #{ C! � # �? r#� '�•'y� •:v�`J�1i{/{'�^�1N{{il.' �e�t+`�µ.:�{f i1 ta' -MfeNfi�rif/{. .1 fJlf{Htp 1 N� *.N t K ,.. {{i.YK 1 { 5:. lil,�j't/1 �,1 t�.�V 4 )111(. /HA 1�i' �{ NYi.i?"`,i� 1;,�i '.: ♦�r�:ii C.,.♦e��.°eel`!lefee�e°,�/�1sf�f�,�,,e°,eel+lSif+JbO,lS,feeJy♦�r f{f�pfe} i l`r.4yee.���i�eee��'�rd�le�'��e{e/i°e°�°l�lfS.�.�`�1i{I°I°5�0�°e°°e°ei°S/`STrSfe{ee e�;,iypCC�Jn{I.+�h{.3� f`i{ reefeE�sJi/.C�"e°1ro°e¢� Y,� �'s��yr�.fS°�; .uS :•�A..,.O:::e. e:J�•a'.il��'•'�feff.,16��f�i.���f• �.���..��i J��.• i{,,�1 �i�, ♦f1 O� �.� ♦�N e�`�.�°6�}!of '\0"le ei,®S fS��,'l�ejf�ie��I•.'r 1. i•t.E..••f.a4:?: L�O �'Of A, 0.s :.Ttt.� •t• e f�iv.4 eje, 4 b:��•. 1� 1. efS�::O•.fYS e:O.:J.• J.•:�.,J: }}:�b�ti v�-_A,�._cv.-.r�-_.C�re��. .-_S .*G.;:a•�.Z.ti..•. t�•..•. !-t°r•:h•4 �. _i�. `4.ss.:p•.•�:v a•�,>•J _,/����/�L�v/�r .�_��_ ?/��_J•�.n_ /`-- d 4. v_� K.,�r-_.�•.•f_. +:.ems 'N.,.�r3 ....3 E-:-�.S'�i�c_Zdr per.•>%�<t=,�+'r�. ati:;'r_� '�=� Z _ "i��=i \-- '�����=����������i�`-= � flu•'_ i A 2, p � ♦1 i _ ram: - -. -_ O.. � � '�. '� Uj tit ol TT .t 1 as 7e5 .ice At p.• t"04 _op_ ed low -- SOUI�olo 9� :z- comm, # • ao TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [XFINAL [ ] FIREPLACE &.CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: - ,C � ® t DATE 10 / 0 INSPECTOR . �aOF SO(/l�o comm, TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ IF NDATION 2ND [ ] INSULATION [V FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: - J76 DATE -INSPECTOR / ,3 rjf s 0 cou TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION P<FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: -`�- - pf �,6 . � DATE INSPECTOR �e FIELD INSPECTION REPORT DATE I COMMENTS FOUNDATION(1ST) � \ ------------------------------------- (�C FOUNDATION (2ND) C t�1i z 0 ----- U' 01) H ROUGH FRAMING& if j PLUMBING — INSULATION PER N.Y. y STATE ENERGY CODE n FINAL f ADDITION4 COMMENTS 1LI O z rn a— � y G z x E� x d b y TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUT-MOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey www.northfork.net/Southold/ PERMIT NO. �.S�J Check Septic Form N.Y.S.D.E.C. Trustees Examined f ,20 Ot Contact: Approved ,20 6-6 Mail to: Disapproved a/c rr�� Phone: c��'►�6' ` 1 Expiration ,20 O L C:} Building Inspector DEC Z�dO APPLICATION FOR BUILDING PERMIT _- - Date , 20 INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector wit(4) sets of plans, accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing, the extension of the permit for an addition six months.Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations,for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspecti 77 ()�_ - 5igna_ature'Mf applicant or name,if a corporation) a o SP NW k<)9_ Rd- �)OU-r N®LO �1H (Mailing address of applicant) 1191 State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder O 1'1 Name of owner of premises io ga)A u (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed wor will be done: (90, Gong- LCI Aog, SO 0T HO 1, House Number Street Hamlet _ County Tax Map No. 1000 Section Block y ;,Y • Lot ":• . Subdivision Filed Map No. .i `�"9 Lot` (Name) 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy I V: Cl rn,') we��I n b. Intended use and occupancy GOIQ!! 3. Nature of work(check which applicable): New Building x Addition Alteration Repair Removal Demolition Other Work (Description) 4. Estimated Cost C-Q(o CX� ,a� Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars QL 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. " 7. Dimensions of existing structures, if any: Front 410 Rear 31 Depth 9 Height X1"+ (- Number of Stories -_1L Dimensions of same structure with alterations or additions: Front LA L Rear 3 Depth y`6 Height 'A-) Number of Stories "�-- 8.' Dimensions of entire new construction: Front c;�14 Rear 1% Depth Height W o Number of Stories k 9. Size of lot: Front —Rear 1 0� S Depth q a I O.`Date of Purchase i Zi XQ 41. Name of Former Owner PETER W!SP f1 11. Zone or use district in which premises are situated 0 12.Does proposed construction violate any zoning law, ordinance or regulation? YES NO'X 1.3. Will lot be re-graded? YES NO Y\ Will excess fill be removed from premises? YES NO 14. Names of Owner of premises SA D.PP 1 . Address Phone No. Name of Architect i[ AR y, Srh i ueA Address _\�T aS C Lkk Phone No Name of Contractor P�r3-t; Ow nZt Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAREQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTY OF 5, APZT 3A U e Q being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)He is the OWN-r--e- (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to efore me this of 2�— 20eP d P a_C:4� ___* - Notary Public Signature of Applicant PATRICIA RICHERT Notarym Public Statp'of New York - No.3b-.4741154: Qustifierl in Nassau/'Suffo i Cou e Commission Expires D ,'OWN OF SOUTHOLD PROPERTY RECORD CARD OWNER STREET VILLAGE DIST. SUB. LOT . V �r �,1 � C:41 nnc �1�1�SCEG1 �CtV t�11 FORMER OWNER N 1�� E J:_Cn Gad Y— k't G TYPE OF BUILDING I i. YP.fl S W 1_< -( " RESLC) SEAS. VL - FARM COMM. CB. MICS. Mkt. Value i LAND IMP. TOTAL DATE REMARKS a5 8 - / � ` C ry - art . �. '/t 1417 7vr, '7® 6 7,!,v - /d i2 s- 04 3()S�j US b.(A 1 C�, uj� arb5K ,It > o� 1o0 -�- a - rur� U o �GrS�n - �58c� Tillable FRONTAGE ON WATER Woodland- FRONTAGE ON ROAD ; :- Meadowland DEPTH House Plot BULKHEAD Total T ......... ■■!■riirliiiii■!■■■!■■■ EMN MEMO ■■■■■■■!■■■!■ ■■■■■■ ■■■■■■■■■■■■■ . . . N/F DREWS o N 69°48'50"E 125.00 CONC \ , MON WIRE FENCE GENERALLY NORTH OF PROPERTY LINE .6' 0.5' N Y 1.6' DIAM. V m CONC. COLUMN i 0 w 0 17.8 m 8' rr 3 N 0.9'—j t8, 6.0' Cy)p POURED CONCRETE N 3.1 N FOUNDATION 1.7 I� MAN-MADE POND ^� z I Fry 7.9 WOOD DECK T --` I WlARSOEA CELLAR THIS AREA ENTRANCE STOCKADE FENCE O N WOOD FRAME D STOCKADE u /FENCE � wo o co jv 3 RESIDENCE 36.1' n 29.9' ` , wooD m (COVERE) Ul �1P'1 O N 9D N N CONC MON Mo -23 50 W 125.00 BAY AVENUE SURVEY OF PART OF LOT 140 IN M P OF NASSAU FARMS SITUATE OG TOWN OF SOUTHOLD S FOLK COUNTY, N.Y. FM# 140 DATE FILED MARCH 28, 19 SURVEYED FOR: ARTHUR BAUER TM# 1000-104-04-033.2 LAURETTA BAUER GUARANTEED TO: SURVEYED: 14 DECEMBER 2006 ARTHUR BAUER LAURETTA BAUER SCALE 1"= 30' COMMONWEALTH LAND TITLE INS. CO. AREA = 24,016 S.F. OR 0.551 ACRES GUARANTEES INDICATED HERE ON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY SURVEYED BY IS AND ON HISTO THE 7777E PREPARED,COMPANY, GOVERNMENTALALF AGENCY, STANLEY J. ISAKSEN, JR. LENDING THE ASSIGNEES OFF LISTED HEREON, LENDING TO INSTITUTION. P.O. BOX 294 GUARANTEES ARE NOT TRANSFERABLE TO NEW UFFOLK. N.Y. 1.1 9 6 ADD177ONAL INSTITU77ONS OR SUBSEQUENT OWNERS. 631 — 34-5835 UNAUTHORIZED ALTERATION OR ADDITION TO THIS SURVEY IS A KOLA TION OF SEC77ON 7209 OF —THE NEW YORK STATE EDUCA77ON LAW. THECOP7ES LANDF 7741S SURVEY MAP SURVEYORS EMBOSSED SEAL EALRSHALL ING IC D ND S VEYOR NOT BE CONSIDERED TO BE A VALID TRUE NYS C. o. 49273 06R 1553 COPY. 1. 11 JAN 07 LOCATE.POURED CONC FOUNDATION (GARAGE) ART&LAURETTA BAUER 2120 SOUTH HARBOR ROAD SOUTHOLD,NY 11971 HLvlblu 4S BLDG.DEPT. 12/12/06 — emaasw `VL T — fV O' cli MUM m El 11 �7 M a m mmmm N � x 411) w O ca -r Fi u FRONT ELEVATIONbo z SCALE: 1/4" = V-0" i - - - - W REAR ELEVATION SCALE: 1/4" = V-0" Z o N W W cr- � � Q 1 IL (V W 60 —its RIGHT ELEVATION- �` P'`O�fE D A t``��� D DATE: D,P.e 3 1� 5-16 — _ - - SCALE: 1/4" = V_011 FEE'% 6 t - RY: )FM AT _ 76�•1F,02 8 i,`A ? .. c�_,R THE: ? Z Li ZD OCCUPAM"J" T OR 1. 1701j!�; /,�"-..TiOC'! -r. F.FL".`�.`RED rf Fk_):,,-l\IIJ f'Y^�.� 1. :v...1,^cc:'r A/� G USE IS UNLAWFUL 2. ROUGH - rF^1,,,!—R,y\+ i. Cl�Jk"I"IiiU Q - - WITHOUT 3. lP�:�u�>�,T�Ci�� m U — - - — — GEPTIF►�ATION OF 4. FINAL - CO3N'ST,;'.` -7l,)N M.UST 4, UONNECTIONS OF OCCUPANCY ev NST LUT�- + ', I F!"" . NAI�.t��G �� T ALL carasTa��ucT��..;� �;_I LL MEET THE REQUIRED. REOUIREVENTS C:°�T N"-jDFS OF NEW ,..z � YOR!< STATE. NOT RES"OtiSiELF-, FO,,R �+ I DESIGN OR CONSTRUCTIO"�. ,, � to DRAWN: MH/MS A!L CONSTRUCTION SHALL Ff ' r�^CFcD,WVEY SCALE: 1/4"=�'-o" MEEK THE REQUIRED ENTS OF THE DO N^ JOB#: CODES OF NEW YORK STATE. ' ' _ — OF f" _; '! TiON �r',�'»' f December 12,2006 HAS BEEN,,r,rt-, SHEET NUMBER: LEFT ELEVATION VOERWRITERS CERTIFICATE FLOOD ZONE T SCALE: 1 4" = 1'-0" Am I REQUIRED G�`^,'�'� - �6 PURS!N,STORM WA f� ��c�'c� iON SF l Y,y �•����. OF THE TOrVN C,-'r- . REVISIONS BLDG.DEPT. 12/12/06 0 ti 34'-0" N 22'-0" 12'-0" rn � u V-41 2" _ _ I O -� 12"DIA.CONCRETE PIER o N NV/2'X2'X1'CONC.FTG. \ - (MIN.3'BELOW GRADE) aN UNDISTURBED SOIL a :a W'/#5 RE-BAR(VERICAL) ;n TO POST/COLUMN ABOVE inuj I I I I I 1).8"THICK POURED CONCRETE FOUNDATION, 3000 psi. 16"XS CONC. 2).FOUNDATION TO HAVE 16"X8"CONCRETE(2X4)KEYWAY FOOTING.FOOTINGS Z Q 0 6 A ; ;FTG.UNDER WALL A - TO HAVE 2-#5 CONTINUOUS RE-BAR.ALL FOOTINGS TO REST ON --j 'w/2-#5 REBAR UNDISTURBED SOIL(MINIMUM 3000#CAPACITY). Q Z N ; ; ; ; N 3).FOUNDATION SLAB TO BE 4"THICK,3000psi CONCRETE ON COMPACTED FILL. u INSTALL 1/2"EXPANSION JOINT MATERIAL WHERE SLAB MEETS ADJOINING f- 1 V-5 3/4" WALLS.COLUMNS MUST ALSO BE BLOCKED OUT AND ISOLATED FROM THE Q REST OF THE SLAB.THE BLOCK-OUTS AT COLUMN BASES SHOULD BE SQUARE � V Z ® ' ; I i AND POSITIONED SO THAT THE POINTS OF THE SQUARE MEET THE CONTROL Q ! °o JOINTS. 24X24X10 i).PROVIDE 2X6 ACQ SILL PLATES UNLESS OTHERWISE NOTED.SILL PLATES Q -1 CONC.FTG. ARE TO BE INSTALLED OVER COP-R-TEX TERMITE SHIELD AND FOAM OR °O ' ' UNDER POST FIBERGLASS SILL GASKET. I W' 5).PROVIDE 5/8"DIA.ANCHOR BOLTS AT 57""O.C.AND W/I 1'-0"OF CORNERS, Q I I INTERSECTIONS AND SPLICED JOINTS.ANCHOR BOLTS ARE TO HAVE A 0o ; ; MINIMUM 8"IMBEDMENT INTO THE CONCRETE.EACH ANCHOR BOLT ARE TO I 1 BE ATTACHED TO SILL PLATES WITH 3X3 SQUARE WASHER AND NUT. I , I 1 I I 1 1 CV I \ I I O I I 1 34'-0" } W Z FOUNDATION PLAN W � SCALE: 1/4" = V-0' 0 Qu cm ~ u DRAWN: MH/MS SCALE: 1/4"=1'-0„ ., JOB#: December 12,2006 e e`a {•' � SHEET NUMBER: =2 REVISIONS BLDG.DEPT. 12/12/06 s ee�� 0 N H 34'-0" U Ln 22'-0" 12'-0" N v Z w u mLn V-0" M ------------- 2842 2842 6X6 POST z 2-2X8 DF#2 HEADER _ 0 1 WI 1 I OI R7tn Q W = ------------------ �a # O N _ LL #ix �9 i ry D W , �� xl O � J N w I N 2842 /2X8 DF#2 CT @16"OC V eoilo FLOOR SLOPE � N 1).PLATE HEIGHT AT 8'-1/2",INCLUDING SILL PLATE. V .-, Z N o � 2).EXTERIOR WALLS TO BE FRAMED WITH 2X4 DF#2 STUDS AT 16"O.C.. Q J Cr I Q CN W --------------------' i--7-- m _ 3).EXTERIOR SHEATHING TO BE 1/2"THICK FIR CDX PLYWOOD. W o w 4"DIA.STEEL COLUMN ' ' o u o O ' Cr ' 4).PROVIDE 2-2X8 OF-2 HEADERS OVER ALL OPENINGS UNLESS u w/2'X2'Xl'CONC.FTG. -v O N N Z bo `� OTHERWISE NOTED.ALL OPENINGS OVER 3 FT.TO HAVE 2 JACK STUDS (, J __ __. w ------- -----------; I N ON EACH SIDE OF OPENING. ( LL. W ¢W 5).ALL EXTERIOR OPENINGS TO HAVE DESIGN-PRESSURE UPGRADES WHERE a GARAGE N _ 2- 1-_3/4X7-_1/4 ML_FL. HDR. - a APPLICABLE.PROVIDE DEBRI-PROTECTION PANELS WITH FASTENING HARDWARE UNLESS OPENINGS HAVE IMPACT GLAZING. J N I-i 4X4 P T•Sw/ J 6).NO SHEETROCK ON INSIDE.ACCESSORY USE ONLY Q o N 24"X24"X10" to CONC.FTG. x to /2X8 DF#2 CJ @16"0C STORAGE P # oo N I cry � P bo ti --------------------- icy 2X4 FRAMED WALL 10'-8 1/2" I 10'-81/2" 1 1 V-8 1/2" m W Z LJ W :D 34'-0" q O FLOOR PLAN Q � m � SCALE; 1/4" = V-0' n r;, .ay �1ti'1a. .K tinr, DRAWN: MH/MS VY y SCALE: 1/4"=1'-0" JOB#: December 12,2006 SHEET NUMBER: H W!, Amej REVISIONS BLDG.DEPT. 12/12/06 0 N � m t-•1 C In 03 -------------------------------- ---------- --------------------------- I ----- -- -- ----------- ----------------------- 12 (J -------------------- ------ -------------------------- - r + 1 I I 1 I I J 11 ' 1 11 O I 1 zM ' DORMER BOLT OVER ---- - -- - ----- -- -- - - -- --_ � DBL. ROOF RAFTERS ; r___ _ __ _ _____ # _ __ _ _ __ ___, , NOTE: 1/2"BOLTS @ 16"OC ' CLLJ PLATES TO BE BOLTED TO V i --___-_-- MAIN RAFTERSW/ , 1).INSTALL 2X4 DF#2 COLLAR TIES AT 4$"O.C..----------------- -- ----- ' 1 1 ' 1/2"DIA.GALV.LAGS W/WASHERS EA.RAFTER 2).APPLY 1/2"THICK FIR CDX SHEATHING OVER ROOF FRAME. I 3).APPLY METAL DRIP EDGE OF ANY UNDERLAY ALONG RAKE EDGES AND 2X8 DF#2 RR @16"OC 4J i , ' DIRECTLY TO THE DECK ALONG EAVES. 2X10 DF#2 BUDGE 4).USE 15#FELT UNDERLAYMENT WITH ASPHALT ROOFING. Q z Z, 12 0 5).ICE E WATER BARRIER TO BE USED IN ALL VALLIES AND INTERSECTIONS W a WITH ROOF AND SIDE WALLS(TYPICAL). O VI i N i i 6).DO NOT INSTALL UNDERLAYMENT ON WET/DAMP PLYWOOD111 SHEATHING O MUST BE DRY AND CLEAN PRIOR TO INSTALLING UNDERLAYMENT. cr UNDERLAYMENT IS NOT TO BE LEFT EXPOSED TO ELEMENTS AT END OF THE WORK DAY.COVER WITH HEAVY-DUTY TARP UNTIL ALL ROOFING IS II 1 COMPLETE. 7).INSTALL ASPHALT ROOFING AS PER MANUFACTURE'S WRITTEN INSTRUCTIONS. 12 ; ; USE GALVANIZED(ZINC COATED)ROOFING NAILS, 11 - 12 GAUGE WITH AT W + LEAST 3/9"DIA. HEADS,LONG ENOUGH TO PENETRATE THROUGH PLYWOOD. Q USE 6 NAILS PER SHINGLE. NAILS ARE TO BE FLUSH WITH SHINGLES BUT NOT CUTTING INTO SHINGLE SURFACE. I I I I i t 1 1 1 1 1 1 i I i 2X$DF#2 RR @16"OC 1 1 1 1 I I -------------- I I I I I I I I 1 1 I I I ROOF PLAN Li � w SCALE: 1/4" = V-0' > QO Qu Co ~ U i' DRAWN: MH/MS SCALE: 1/4"=Y-0.. JOB December 12,2006 SHEET NUMBER: m REVISIONS BLDG.DEPT. 12/12/C6 ASPHALT ROOFING ICE I WATER UNDERLAYMENT 15#FELT UNDERLAYMENT TO BE USED OF ROOF AREAS �ZX10 DF#2 1/2"APA RATED SHEATHING OF 4:12 OR LESS ROOF PITCH RIDGE 2X8 DF#2 RR @ib"OC — - - — RIDGE VENT AS PER N.Y.S.RES.CODE 12 i f�► 3-1/2G� 6 0` VI�` 2X9 0 .-I iv 2- 1-3/4X7-1/4 ML FL.HEADER — - - — --- 2X9 DF#2 CJ W"OL — - -— -- --' # j 2X8 DF2 CJ(R6"OC r\ rn e j! CEDAR PERFECTION ti Z [N EflWOOD SIDING t j 7Ffl 30#FELT UNDERLAYMENT 4"DIA. �G m � STEEL 2X4 DF$2 STUDS @16"OC y tlo COLUMN c U o I Oo d d.- o d d. d d. d c• d. -° 2X8 ACQ SILL PLATE a 4"THICK CONC.SLAB _° "� 4 a COP-R-TEXT TERMITE SHIELD d o 0 8"PC REINFORCED w/WMM ib"XS"CONC.FTC. D FOAM SILL GASKET m 24"X24"X12"FOUNDATION D.< OVER CRUSHED GRAVEL W/2-#5 REBAR 5/8"DIA.ANCHOR BOLTS OR COMPACTED SAND CONC.FTG. W/3X3 50.WASHERS @57"OC W 16"X8"CONC.FTG. � w/2-#5 REBAR V z SECTIONA-A SCALE: 1/4" = 1'-0" u La 4" 4' 0- 24"OC q^ 7 Q H V z cc i if cn Lip #10 STAINLESS STEEL '! ( \ \ %t I ' f I t / / / \\•• I / ® f' I \\ ® / ( 1 , f ( / 11 I OR GALVANIZED • I I I ( / 11 ) •� V • I / ( 11• / I / ( I WOOD SCREWS W/ /-1 RS @ WASHERS I. O.C. II 12"OC I I 1 ( I i, l I , 'li 12"O.C. l I � I f � •• li • I � i � � _ � � — � it I — I � I � 1 �— � � • � � • I til � I I � I � 1 � i o 1 ! 3/4 SHE APA PLYWOOD O I ` / ®I f` SHE 1 "APA RATED SHEATHING I \ I ® I I '\1 / • ' I I I ' ' •• I ` 1 5 • i / .• I ` / I ( GRADE PLYWOOD (ALTERNATNIVE:7/16"O.S.B.) 1/2"APA RATED SHEATHING ll I LI I I I I I I GRADE PLYWOOD (ALTERNATiVIVE:7/16"0.5.8J Lj I\ I O / W 2X4 DF42 I t f // I #10 STAINLESS STEEL if l f I I W STUDS / l l / I I l OR GALVANIZED / l WOOD SCREWS W/ I / �\ \ •I Q O • , I / I l\1 0 / ( l\\•• / l I • 1 I l ( \\1 • WASHERS @ 12"O.C. ( j \t \� / i / \ll / Q ` s I f WINDOWSILL TYPICAL WINDOW OPENING I m #10 STAINLESS STEEL (LESS THAN 4-OX8-0"OPENING) v I I I OR GALVANIZED II / / I ) WOOD SCREWS W/ I I ) I WASHERS @ 12"O.C. ® I I l I I I • MULTIPLE PLYWOOD ASSEMBLIES TYPICAIL DOOR OPENING 2-2X4 DF#2 STUDS CONNECTED Y TOGETHER WITH STAINLESS STEEL (LESS lfHAN 4'-QX8'-0"OPENING) ,•n' °�'w":•�"'`°'""°.��"'t a'IS OR GALVIN17ED BOLTS W/WASHERS a" AND Nurs @ z'-o°O.C. TYPICAL MULTIPLE OPENINGS s?" of ,�.`' t'i ' N DRAWN: MH/MS (MORE THAN 4'- OX8 0 OPENI G) WIND-BORNE DEBRIS PROTECTION FOR WOOD STRUCTURAL PANELAy "5� &fir SCALE: 1/4"-1'-0" Y M S 11 hr'(..1.���5 LE 1609.1.4 N.Y.S. RE5. CODE: AILTERNATIVE FOR OPENING PROTECTION (IF NOT USING IMPACT GLAZING) ' JOB#: AS PER TAB '`' ' 1'�``: `. "a December 12,2006 WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS WOOD STRUCTURAL PANELS WITH A MINIMUM THICKNESS OF 7/16 "h,.`vv'��a+:` �" � :� �t SHEET NUMBER: AND MAXIMUM PANEL SPAN OF 8 FEET SHALL BE PERMITTED FOR OPENING PROTECTION IN ONE-AND TWO-STORY BUILDINGS.PANELS SHALL BE PRECUT TO "' :: COVER GLAZED OPENINGS WITH ATTACHMENT HARDWARE PROVIDED. (REFER TO SECTION 1609.1.4, 1609.6.5 AND TABLE 1609.1.4 OF N.Y.S. RESIDENTIAL CONSTRUCTION CODE).THIS IS NOT A SUBSTITUTION FOR DESIGN-PRESSURE. ALL OPENINGS MUST HAVE DESIGN-PRESSURE UPGRADES WHERE APPLICABLE. ALL PANELS MUST BE CUT TO SIZE AND READY TO USE ON ANY NEW WINDOWS AND DOORS.SHUTTERS MUST BE MARKED FOR WHAT OPENING IT IS TO COVER. A=5 HARDWARE MUST ACCOMPANY SHUTTERS FOR INSTALLATIOIN. REVISIONS BLDG.DEPT. 12/12/C6 WIND LOAD PATH CONNECTION AND CONSTRUCTION DETAIL DRAWINGS USE THE FOLLOWING APPROVED UBP METAL CONNECTORS FOR PROPER WIND RE51STANT 4 GOOD CONSTRUCTION. FOLLOW MANUFACTURE'S RECOMMENDED INSTALLATION INSTRUCTIONS TO ACHIEVE MAXIMUM UPLIFT LOAD CAPACITY. KING STUDS ENDWALL RAFTER WALL STUD n CRIPPLE STUD BOTTOM PLATE ®.® �.• o RIDGE LEDGER BATHTUB HEADER DOUBLE JOIST ®,QS SIDEWALL RAFTER --Q JACK STUDS FLOOR USP NUMBER DESCRIPTION APPLICATION 1ST. ADS5 HOLD DOWN CONNECT TO 1 SIDE OF ALL CORNERS ANCHOR TO FOUNDATION W/ANCHOR BOLTS CONNECT TO 1 SIDE OF ALL CORNERS ON BATH SPA TUBS TO HAVE A DOUBLE FLOOR JOISTS UNDER FOR ADDED SUPPORT HOLD DOWN BOTH CONNECT PLATE E 2ND FLOOR AND TOP LOCATION USP NUMBER DESCRIPTION APPLICATION LOCATION USP NUMBER DESCRIPTION APPLICATION 7RAFTER SIZE USP NUMBER DESCRIPTION APPLICATION SUPPORT EACH WALL RUNNING PARALLEL WITH THE FLOOR p 2ND. ADS5 ALL OPENINGS LSTA12 1-1/4"x12"2 a.STRAP APPLY TO EACH JACK STUD ROOF LSTA24 1-114"x24"20 a.STRAP APPLY OVER RIDGE TO EACH RAFTER x6-2x8 LS26 18 a.SLOPE HANGER APPLY TO EACH RAFTER I LEDGER JOIST DIRECTION WITH(2)JOISTS.UNDER WALL. " ANCHOR PLATES OF 1ST.FLOOR,CONNECT THROUGH g g r THE FLOORS TO EACH OTHER WI THREADED ROD. ALL OPENINGS RT3 OR RT7 TYDOWN ANCHOR JAPPLYTO EACH CRIPPLE STUD 2X10 I LS210 118ga,SLOPE HANGER APPLYTO EACH RAFTER I LEDGER FOR JOIST NOT DIRECTLY UNDER PARALLEL WALLS,PROVIDE (14 4 BLOCKING @24"OC WALL STUD THROUGH-ROOF EXHAUST VENTS SELECTED AND C M ~+ k LOCATED BY CONTRACTOR METAL STRAP t— U o 2 CRICKET ATTOP-SIDE OF VENTILATION CHANNEL U c oho CHIMNEY AS REQUIRED � RIM BOARD RAFTER *r o RAFTEJVVEN' SILL PLATE(S) TILATION "Y WALL SHEATHING NTAIN �+ SIDEWALL FLASHING WOOD JOIST L j FOUNDATION TOP PLATE BLOCKING FINISH WALL AND MOISTURE 2x4 LEDGER BLOCKING STAPPING TO BE ATTACHED TO WALL STUDS @48.00 BARRIER TO LAP FLASHING 2x4 SOFFIT JOIST AT WALL--MAINTAIN GAP ATTIC SHALL BE PROVIDED FASCIA AND ALL WINDOWiDOOR OPENING JACK STUDS MINIMUM NET FREE VENTILAFLOOR JOIST DEPTH USP NUMBER DESCRIPTION APPLICATION BETWEEN WALL FINISH AND WALL STUD NOT LESS THAN 11150 OF TH GUTTER ROOFING TO AVOID SOAKING WOOD GIRDER INSTALL 4'0"O.C. THE SPACE VENTILATED. ALCONTIN.SCREENED VENT 4"-8" LSTA24 1-1/4"x24"20ga.STRAP AND JACK STUDS SHALL BE COVERED WITH CCONTIN,SOFFIT/EXT.PLYWOOD ON ALL OPENINGS PROVIDE HEMMED EDGE AT RESISTANT METAL MESH WI INSTALL 4'0"O.C. FLASHING TO FORM CHANNEL LOCATION JUSPNUMBER1 DESCRIPTION APPLICATION OPENINGS OF 1/,INCH IN DIMENSION. SOFFITED EAVE 8"-14" LSTA30 1-1/4"x30"18ga.STRAP AND JACK STUDS AND SO AS TO MAINTAIN AIR CONNECT TO ON ALL OPENINGS / GAP TO PREVENT CAPILLARY 4"-6'RAFTER RT10 10-3/4"x 18ga.TYDOWN ANCHOR EACH RAFTER PROVIDE BLOCKING BETWEEN JOISTS THAT ARE SPICED AND INSTALL 4'0"O.C. ACTION 14"-16" TLSTA36 1-1/4'k36"16ga.STRAP AND JACK STUDS 8"-12"RAFTER RT20 21-1/8"x 20ga.TYDOWN AINCHOR CONNECT TO ROOF VENTILATION / OVER BEARING WALLS AND HEADERS EACH RAFTER SOFFITED EAVE DETAIL uj ON ALL OPENINGS KEEP ROOFING NAILS OUT 2ND.FLOOR WALL OF FLASHING ( IS ROOFING LAPS BASE FLASHING 41NCHES RAFTER � � (fl BASE FLASHING WRAPS CORNERS, RIDGE CAP OF SAME J \/ EXTENDS UNDER SHINGLES AT MATERIAL AS ROOFING I--I SIDES 4 INCHES AND LAPS I NAILED TO SHEATHING t R SHINGLES AT BASE MIN.41NCHES THROUGH VENT v W WOOD JOIST Q 0 Z �—�• SIDE WALL FLASHING TOP PLATE GIRDER/HEADER � � 187 FLOOR WALL STAPPING TO BE ATTACHED TO WALL STUDS @48"OC WOOD JOIST V AND ALL WINDOW/DOOR OPENING JACK STUDS METAL FLASHING AT ALL EAVES,SIDEWALLS, WALL STUD V FLOOR JOIST DEPTH USP NUMBER DESCRIPTION APPLICATION AND RAKES—PROVIDE HEMMED EDGES SO RAFTER INSTALL 4'0'O.C. AS TO FORM DRAINAGE CHANNELS AND 4'-8" LSTA36 1-1/4 x36"18 a.STRAP AND JACK STUDS PREVENT CAPILLARY ACTION LOCATION USP NUMBER DESCRIPTION APPLICATION 9 PRE-MANUFACTURED Z ON ALL OPENINGS CONNECT EACH RIDGE VENT FOLDS KEEP SHEATHING MIN.1-112" ALL JOISTS CONNECTED TO A FLUSH HEADER TO BE SUPPORTED WITH RAFTERIPLATE RT15 TYDOWN ANCHOR FROM PEAK TO ALLOW FREE THE PROPER STEEL CONNECTOR. INSTALL 4'0"O.C. RAFTER TO PLATE OVER RIDGE TO AIR PASSAGE IF ABLE,SET FIR JOISTS APROX,1/2"HIGHER THAN LVL HEADERS V W-16" MSTA48 1-1/4"x48"16ga.STRAP AND JACK STUDS CONNECT OVER CONFORM TO SLOPE TO ALLOW FOR SHRINKAGE.&REDUCE BUMP OUTS ON ALL OPENINGS PLATENVALL SPTH4 STUD PLATE ANCHOR PLATES TO EACH STUD OF ROOF W DBL.SILL PLATE f fP TERMITE SHIELD F I r SUBFLCOR SILL GASKET / R' WOOD JOISTS f NEOPRENE TYP.CON 6 MIL C.FOUNDATION A .POLY SLAB GASKET 2x6/2x8 CONTINUOUS WOOD PLATE DAMPPROOF EXTERIOR 6 MIL. v, , BOLTED TO STEEL BEAM WI T H V ' 6MIL POLY ON EXTERIOR _ I I/Z"DIA, SOLTS 48"o.c,STAG. GRANULAR FILL • v � STEEL COLUMN less a " ^ CONC.SLAB 4 4 4 A o e \ i ROOF JACK 4 � STEEL BEAM o a e 0 1.a COMPACT FILL 4"x 114"x 8" STEEL ROOFING LAPS C KEYWAY FOOTING o v r ° UJITA TOP AND BOTTOM PLATE•^ • ^ � 4 t1 • FLASHING AT 1/2" GROUT (USP ANCHOR BOLT r, e CONC.FTG. p p t o' WITH 3)(3. e ANCHOR BOLT CONNECTION USE(USP LBPS SUOR BP583)WASHERS SIDES AND TOP REINFORCING BAR FOUNDATION 5#8"CIA-ANCHOR BOLT _. i I 13"STEEL COLUMN DRAIN TILE N`p ANCHOR BOLT CONNECTION SUPPORTING MAXIMUM SPACING FLASHING LAPS - l 10 KIPS J SILL PLATE TO FOUNDATION ROOFING AT BOTTOM -- CRAWL SPACE OR FOUNDATION 1 STORY 72'OC W Z TYPICAL BEAM DETAIL TYPICAL CONC.FOUNDATION.APPLY PILASTERS SILL PLATE TO FOUNDATION 2 STORIES 36'OC Z W WHERE NEEDED FOR STRUCTURAL BRACING. MIN.3'STEEL COLUMN ANCHORED TO 24'x24"x12"CONC.FTG. CRAWL SPACE OR FOUNDATION STEEL / BOTTOM BEARING W WALL BOTTOM PLATE TO FOUNDATION 1-2 STORIES 57"OC SLAB-ON-GRADE ROOF JACKS 4 VENTS DETAIL Q p �—SUBFLOOR QC� CONC.SLAB DOORFRAME ,5 6X6 1 Oil 0 WWM 6ARAE I _ U COMPACT FILL DOOR I Q— ' USE 2X8 JOIST FOR SLOCKOUT STEEL BEAM •=' 4' SLAB ;r = P.T.PLATE W/6X6 WMM CQ SLOPE 1/2"AIR SPACE .< A • . ° 4"DRIVEWAY�� NOTCH JOIST AND ADJUST HEIGHT ^ f+r ° .�'1�" (WITH ANAILING PLATE IF NEEDED) *' ' a AT END AND a of C-a IDES OF WOOD a TO BE APROX.112"OR HIGHER THAN �„ fr rp ., GRADE 4 -z�----z�---- o= °D o ° STEEL BEAM TO ALLOW FOR SHRINKAGE �+ s•• «' 4 ° 4 p = BEAMS II—I I I I I 4 e• • I • (PROVIDE STRAPPING TO KEEP JOISTS ALIGNED) 6X6 W.W.M. — — — — • aaa 4 1Iv 4 4 4 SUBFLO f • •a l) A ° ��NOTCH BEAM FOR MUDSILL IF REQUIRED—MAXIMUM a • 4 REINFORCING BAR NOTCH EQUALS 1/4 DEPTH OF BEAM � o s II=1I ry �J e•. GIST #' eF, x n "o •r -• REINFORCING BAR a e o y � DRAIN TILE I. ►I A`• II _/) a°°.e II=P �/ tS ''` 1' y DRAWN: MH/MS 12" s SHEET METAL 130#FELT UNDER BEAM AT POINT f f r '• k OF CONTACT WITH CONCRETE OR CONC.BLOCK '�T1_ ,f t_ m STEEL BE1Id SCALE: 1/4"=1`-0" TYPICAL CONC.MONOLITHIC FOUNDATION.REINFORCE WITH(2)#4 REINFORCING BARS THICKEN SLABS BENEATH BEARING WALLS AND COLUMNS. ° SHIMS TO LEVEL BEAM PLATE( .T Oy, g;n.-•• ' JOB#: REINFORCE FOOTING WITH(2)#4 REINFORCING BARS. �Q>p€ 3"MINIMUM BEARING SURFACE FOR WOOD BEAM GARAGE DOOR BLOCKOUT !, 'tt3+;., December 12,2006 BEAM POCKETw � /' SHEET NUMBER: w.. A=6 REVISIONS BLDG.DEPT. 12/12/06 WIND FRAMING NOTES NAILING SCHEDULE PLAN CONTENTS: -�- G EN ER A L N O 1t E6 1),RIDGE-TO-RAFTER ASSEMBLY: ROOF FRAMING: OCCUPANCY CLASSIFICATION R3 RESIDENTIAL 1-1/4"x 20 gauge strap shall be attached to each pair of rafters in accordance to table 3.4. JOINT DESCRIPTION NAIL Ali NOTES BUILDING USE ACCESSORY STRUCTURE When a collar tie is used in Ieu of a ridge strap,the number of 10d common nails required QTY. SPACING in each end of the collar tie need not exceed the tabulated number of 8d nails in the strap. RAFTER TO 6 WALL:3-81d COMMON EACH BUILDING HEIGHT 15'-9 1/2" CONSTRUCTION NOTES. '•�► •�. TOP PLATE 10'WALL:4-t8d COMMON RAFTER TOE-NAIL 1).The information within this set of construction documents is related to basic design 2).RAFTER-TO-WALL ASSEMBLY: TOTAL 5Q, FT, OF CONSTRUCTION GARAGE: 528 SQ, FT.,STORAGE: 216 50. FT., PORCH: l2 50. FT, �•. ���� intent and framing details.They are intended as a construction aid,not a substitute Lateral framing and shear wall connections for rafter,ceiling or truss to tap plate shall be in CEILING JOIST 8'WALL:3-81d COMMON EACH TOE-NAIL for generally accepted good building practice and compliance with current New York accordance to table 3.3.When a rafter or truss do not fail in line with studs below,rafters TO TOP PLATE 19 WALL:443d COMMON JOIST State building codes.The General Contractor is responsible for providing standard or trusses shall be attached to the wall top plate and the wall top plate shall be attached to CEILING JOIST TO AS PER TABLE 3.7 EACH FACE DESIGN CRITERIA PRESCRIPTIVE AS PER N,Y,S, RESIDENTIAL CONSTRUCTION GODS AND construction details and procedures to ensure a professionally finished,structurally the to the wall stud with uplift connections.Roofs overhanging the take side of the building PARALLEL RAFTER WFCMI-SBC LAP NAIL 1995 5BG HIGH WIND EDITION WOOD FRAME CONSTRUCTION MANUAL sound and a weatherproof completed product. shall be connected with uplift connections in accordance with table 3.3c. CEILING JOIST LAPS AS PER TABLE 3.7 EACH FACE FRAMING ELEMENTS AS PER FLOOR PLANS CRO55 SECTION AND GENERAL NOTES OVER PARTITION WFCMI-SBC LAP NAIL EXT. BALCONIES 60 2).The General Contractor is responsible for ensuring that all work and construction 3).WALL-TO-WALL ASSEMBLY: COLLAR TIE AS PER TABLE 3.4 EACH FACE DECKS meets current federal,state,county and local codes,ordinances and regulations,etc. Wail studs above and studs below a floor level shall be attached with uplift connections in 40 esa codes are to be considered as part of the specifications for this building and accordance with table 3.3b.When wall studs above do not fall in line with studs below,the TO RAFTER WFCM'-SBC END NAIL ATTICS w/o STORAGE 10 srmuld be adhered to even if in variance with the plan. studs shall be attached to a common member in the floor assembly with uplift connectors in BLOCKING EACH TOE ATTICS w/ STORAGE 2-8d COMMON EACH 0 accordance with table 3.3. TO RAFTER END NAIL DESIGN LOAD CALCULATIONS ROOF (GROUND SNOW LOAD) 45 3).Di nsions shall take precedent over scaled drawings. RIM BOARD EACH END (LIVE LOADS P5F) N (DO NOS SCALE DRAWINGS). 4).WALL ASSEMBLY TO FOUNDATION: TO RAFTER 2-16d C+OMMON END NAIL ROOMS (OTHER THAN SLEEPING) 40 "r First wall studs shall be connected to the foundation,sill plate,or bottom plate with uplift ROOMS (SLEEPING) 30 4).The desi et has not been engaged for construction supervision and assumes no connectors.Steel straps shall have a minimum embedment of rtrches in concrete WALL FRAMING: STAIRS ro responsibility f construction coordinating w th these plans,nor responsibility for foundation and slab-on-grade,15 inches in masonry block undatiorrs,or lapped under NAIL NAIL 40 F. Q construction me s,methods,techniques,sequences,or procedures,or for safety the plate and nailed in accordance with table 3.3b.W e i�steel straps are lapped under the JOINT DESCRIPTION NOTES GAURDRAILS (ANY DIRECTION) 200 Fj QTY. SPACING precautions and pr rams in connection with the work.There are no warranties fora bottom plate,3 inch square washes shall be used tyitli the anchor bolts.Anchor bolt EX 051J E CATAGORY C specific use expressegor implied in the use of these plans. spacing is to be spaced and sized in accordance to table 3.2a.In addition to spacing, TOP PLATE TO PER FACE NAIL 2-16a1 COMMON ti v 2 anchor bolts are to be spaced between 6-12 Vfthes from the end of a sill plate and all TOP PLATE FOOT SEE NOTE:1 LOAD PATH SEE CONSTRUCTION ANDWIND PATH CONNECTION 5).Refer to the Window and Door schedule for exterior openings. corners. TOP PLATES AT JOINTS FACE (ROOF - FOUNDATION) DETAIL AGE<GENERAL NOTE PAGE y 4-16c COMMON o INTERSECTIONS EA.SIDE NAIL v �» 6).The General Contractor ii to ensure that masonry or prefabracted fireplaces meets 5).TYPE I EXTERIOR SHEARWALL CONNECTIONS: STUD TO 2 NAILING SCHEDULE SEE GENERAL NOTE PAGE V O.C. FACE xti U or exceeds manufacture's specifications and applicable codes. Type I exterior shear wails with a minimum of 7116 inch wood structural panel on the exterior STUD 2-16c COMMON .CNAIL EGRESS SEE FLOOR PLANS AND WINDOW SCHEDULE attached with 8d common nails at 6"o.c.at the panel edges and 12"o.c.in the field,and FIRE PROTECTION Sym,. 7).The General Contractor is to consult with the owner for all built-in items 1/2 inch gypsum wallboard on the interior attached with 5d cooler nails at 7"o.c.at panel HEADER TO 16d(COMMON 16"O.C. FACE (SMOKE< G02 DETECTORS) ® SEE FLOOR PLANS such as bookcases,shelving,pantry,closets,trims,etc. edges and 10"o.c.in the field shall be in accordance with the length requirements specified HEADER ALONG EDGES NAIL z y O in table 3.15a b. TOP OR BOTTOM 2- 6Ci COMMON PER 2x4 STUD END TRUSS DESIGN N/A -STANDARD STICK FRAME CONSTRUCTION 8).Wind load requirements shall be taken�to account during construction. :`� 1 PLATE TO STUD 3- 6di COMMON PER 2x6 STUD NAIL ENERGY CALCULATIONS RESGHEGK 3.1.3 6).TYPE 11 EXTERIOR SHEARWALL CONNECTIONS: BOTTOM PLATE TO: FOUNDATION NOTES: Type 11 exterior sh'earwalis shall meet the requirements of table 3.15a-b times the appropriate PER FACE NAIL FLOOR JOIST,BAND JOIST, 2-16tlCOMMON CLIMATIC & GEOGRAPHIC DESIGN CRITERIA length adjustment factors in table 3.16. FOOT SEE NOTE:1,2 1).The General Contractor and Mason to review ns,elevations,details and notes to END JOIST OR BLOCKING P GROUND WIND SEISMIC FROST WINTER ICESHIELD determine intended heights of finished floors)above` ical grade. SNOW SPEED DESIGN WEATHERING LINE TERMITE DECAY DESIGN UNDERLAYMENT FLOOD 7),INTE�ORSHEARWALLCONNECTIONS: FLOOR FRAMING: HAZARDS Allows a sidewall lengths provided in table 3.14 shall be permitted to be increased when LOAD (MPH) CATEGORY DEPTH TEMP. REQUIRED 2).All footings to rest on undisturbed(virgin)soil. Interior shearwalls are used.Sheathing and connections shall be in accordance with JOINT DESCRIPTION NAIL NAIL NOTES QTY. SPACING MODERATE SLIGHT TO �4.4.2 and 2.2.4 respectively. 45 LBS. 120 B SEVERE 3 FT. 11 NONE 3).Provide 1/2"expansion joint material between concrete sl sand abutting JOIST TO: PER TOE TO HEAVY MODERATE - concrete or masonry walls occuring in exterior or unheated int ' r areas. 8).CONNECTIONS AROUND EXTERIOR WALL OPENINGS: SILL,TOP PLATE OR GIRDER 4-8!d COMMON JOIST NAIL ROOF SHEATHING REQUIREMENTS FOR WIND LOADS: UJ 4).An new concrete walls being attached to existing concrete stru ure shall Header and/or girder connections shall be attached with uplift connections in accordance BRIDGING EACH TOE 0 y 9 g with table 3.5.Window sill plates shall be have steel connectors In accordance with table 2-SId COMMON NAIL SPACING NAIL SPACING AT INTERMEDIATE be installed with#4 re-bar,18"long at 12'o.c..Use approved epoxy installation. P TO JOIST END NAIL SHEATHING LOCATION NOTES 3.5. AT PANEL EDGES SUPPORTS IN THE PANEL FIELD BLOCKING EACH TOE poured Unless otherwise noted,all slabs on grade to wire a me p reinforcing. C icing. to be TO JOIST 2-i�d COMMON END NAIL 4'PERIMETER EDGE ZONE 8d COMMON @ 6"O.C. 8d COMMON @ 6"O.C. SEE NOTES:1,3 poured on 4 inch thick sand or gravel fill with 6x6 wire mesh reinforcing.In rior slabs 9).CATHEDRAL CEILING ASSEMBLY: Where a ridge is to be used as a structural beam,the rafters shall either be notched and BLOCKING TO: EACH TOE SEE NOTES:1(BOTH FIELDS) to be minimum 3-1l2 inch thick.All fill to be compacted to 95%relative dens with 9 3-1(6d COMMON INTERIOR ZONE 8d COMMON @ 6"O.C. Sd COMMON @ 12"O.C. 6"maximum lifts(layers). anchored on top of the beam or slope connectors shall be attached to each rafter-to-ridge SILL OR TOP PLATE BLOCK NAIL NOTE:2 FOR PANEL FIELD LLJ 6).Crawls aces to be provided with a minimum 18"x24"access opening.Instal ne along the open ceiling part of the building.Connections to the ridge and wall shall be be LEDGER STRIP EACH FACE GABLE ENDWALL RAKE AND RAKE TRUSS 8d COMMON @ 4"O.C. 8d COMMON @ 4"O.C. SEE NOTES:1,3 ( � 1- } P P P g attached with the above requirements. TO BEAM 3-16d COMMON JOIST NAIL v 0 8x16 cast iron foundation vent for every 150 sq.ft.of area. NOTES Z DECK AND COVERED PORCH NOTES: JOIST ON LEDGER 3-Sid COMMON PER TOE 7).Dampproof exterior of foundation with bituminous coating as per section R406 of TO BEAM JOIST NAiL Z N.Y.S.Residential Construction Code.A 6-mil polyethylene„film shall be applied over 1).Unless otherwise noted,all framing material to be#1 ACQ pressure treated lumber. BAND JOIST PER END LJ THESE NOTES ARE ONLY TO BE REFERRED TO IF MENTIONED IN SCHEDULE NOTES ONLY. 0 the below grade portion of exterior walls prior to bailing' II fasteners,hangers and anchors to be galvinized or stainless steel. 3-1E8d COMMON H r TO JOIST JOIST NAIL 1).For roof sheathing within 4 feet of the perimeter edge of the roof,Including 4 feet on each side of the roof peak, F" BAND JOIST TO: PER TOE NAIL the 4 foot perimeter edge zone attachments required shall be used. U 8).Drainage as per section R405 of N.Y.S.Residenti�Construction Code. 2). irders for deck joists to be bolted to each post with washers and nuts. 2-1Ed COMMON Girde on concrete piers shall be anchored with proper steel connectors anchored SILL OR TOP PLATE FOOT SEE NOTE:1 F RAM I N G N OT E S g 2).Tabulated 12 inch o.c.nail spacing assumes sheathing attached to rafter/truss framing members with G>0.49. into co rete with a minimum 1/2"die x 7"Ion anchor bolt with washers and nuts. R F H EAT I N : For framing members with<0.42<G<0.49,the nail spacing shall be reduced to 6 inches o.c. en 1).All framing techniques and methods as prescriptive design of 1995 SBC High Wind NAIL NAIL 3).Posts s porting girders shall be anchored to a 12"x12"x12"thick concrete footing. JOINT DESCRIPTION Z Edition Wood Framing Constructio;talled al. QTY. SPACING 3}.Tabulated 4 inch o.c.nail spacing assumes sheathing to rafter/truss framing members with G>0.49.For Use a minim 1/2"dia x 7"long anchor bolt with washers and nuts.Footings Shall be 3 ft. a O below grade.\supportedd ith covered roofs shall have 12"dia.concrete piers for the girders. framing members with 0.42<G<0.49,the nail spacing shall be reduced to 3 inches o.c. STRUCTURAL PANEL gd AS PER TABLE 3.8 U z).Unless otherwise noted,all fra ructural wood material to be#2+BTR. WFCM-SBC WALL SHEATHING REQUIREMENTS FOR WIND LOADS: W Douglas Fir. 4).Deck joistslocking at 8'0 o.c.. CEILING SHEATHING: NAIL SPACING NAIL SPACING AT INTERMEDIATE NOTES 3).Floors,walls,ceilings rafteaced at 16 inches o.c.unless noted SHEATHING LOCATION Q ) 9 P 5).A minimumh flashing shall be installed between the building and ledger. NAIL NAIL AT PANEL EDGES SUPPORTS IN THE PANEL FIELD otherwise. JOINT DESCRIPTION �I Ledger to be f wilding with 112"dia.bolts with washers and nuts QTY. SPACING SEE NOTES:1,3(BOTH FIELDS) where needed 4'EDGE ZONE ed COMMON @ 6"O.C. 8d COMMON @ 12"O.C. NOTE:2 FOR PANEL FIELD 4).Unless otherwise noted,all bell headers to be(2)2x10#2+BTR.Doug.Fir. GYPSUM 7' O.C.EDGE WALLBOARD Sd COOLERS 10"O.C.FIELD INTERIOR ZONE 8d COMMON Bearing wall headers to have(2)js and(2)full length studs on each side of all @ 6"O.C. 8d COMMON @ 12"O.C. SEE NOTE:3 openings.LVL headers to have(3uds and(2)full length studs on each side of 6).Concrete be a inimum 6"above grade. openings.Bearing wall window silllso have(2)window sill plates for 2x4 wall WALL SHEATHING: NOTES 7).All joists torted with angers and anchors.Each Joist shall also be anchoredopenings between 4'1 and 6'0 andll openings between 611 and 8'9.Provide fire NAIL NAILand blockin where a likable. to girder(s). JOINT DESCRIPTION THESE NOTES ARE ONLY TO BE REFERRED TO IF MENTIONED IN SCHEDULE NOTES ONLY. 9 PP QTY. SPACING 8).Covered Rl be assemble nd anchored the same manner as a typical building. STRUCTURAL AS PER TABLE 3.9 1).For wall sheathingwithin 4 feet of the corners,the 4 foot edge zone attachment re 5).All flush beams/headers to be i with heavy duty galvinized hangers and PANELS 8d COMMON WFCM-SBC ) 9 requirements shall anchors where applicable to all connecting joists. PLUM NG NOTES be used. 7/16"OSB 6d COMMON 3"O.C.EDGE 6).Double up floor joists under w lls that run parallel to the floorjoist and under bathtubs. 1).Ail water supply,drainage and venting to b 'nstalled as per N.Y.S.Residential PLYWOOD 6"O.C.FIELD 2).Tabulated 12 Inch o.c.nail spacing assumes sheathing attached to stud framing members with Floors to have ceramic tile installed shall be verified for proper load capacity unless noted Construction Code. GYPSUM 7" O.C.EDGE G>0.49.For framing members with 0.42<G<,the nail spacings shall be reduced to 6 inches o.c. on plans. r' WALLBOARD 5d COOLERS 10"O.0.FIELD 7).Provide 2-1-3/4"thick microlams(height to match floor joists)around stairwell and/or 2).Verify septic system with the Engineer for Suffolk ounty Health Department approval. 3).For exterior panel siding,galvinized box nails shall be permitted to be substituted for common nails. other access openings uniessbtherwise noted(typical). FLOOR SHEATHING: NOTE: 3).If wall studs,plates or joists are cutout during installs n for any plumbing related work, NAIL NAIL CONTRACTOR TO PROVIDE SOIL TEST TO VERIFY provide adequate bracing and plates to protect and secure a structure.Veri with the JOINT DESCRIPTION B).Dormers running up roof afters are to be supported by double rafters on either side p eq 9 p P fY OTY. SPACING where applicable unless otherwise noted. state code and manufacture's recommendation for maximu4bole size and spacing permitted. STRUCTURAL PANELS 8d COMMOMI 6"O.C.EDGE EXISTING CONDITIONS. MINIMUM 3000# CAPACITY. w z 9).Provide blocking/bdd ng in floorjoists at 8'0 o.c..Use solid blocking in floor joists HVAC SYSTEM NOT S 1"OR LESS 12'O.C.FIELD � Lei 1).PROVIDE 5/8'TYPE-X SHEETROCK FIRE STOPPING AT 10'0 MAXIMUM DISTANCES FOR NON ACCESSIBLE AREAS. under all bearing walls. 1).Mechanical subcontractor is responsible for adhearin to all a Iicabie codes and safe 2 USE SIMPSON HANGERS AND ANCHORS WITH Z-MAX TRIPPLE PROTECTIVE COATING FOR CONTACT WITH ACQ. ) P 9 Pp safety NOTES: )• w D requirements. 3).INSTALL 1-Co2 DETECTOR IN ADDITION TO SMOKE ALARMS PER FLOOR. 0 10).Provide insulation baffles at eave vents between rafters.Install draft blocking as < O THESE NOTES ARE ONLY TO BE REFERRED TO IF needed. 2).HVAC subcontractor is to fully coordinate all system data and tequiremyants with the MENTIONED IN SCHEDULE NOTES ONLY. Section R602.8 -FIREBLOCKING REQUIRED Q = equipment supplier. Ftreblocktng shall be provided to cut off all concealed draft openings(both vertical and horizontal) Q 11).Unless otherwise noted,all roofs and walls to have a minimum 1/2"thick,4-ply Fir 1).Nailing requirements are based on iwall sheathing and to form en effective fire barrier between stories,and between a top story and the roof space. CO exterior sheathing grade plywood.Plywood to cover over plates and headers. 3).HVAC subcontractor to provide final system layout drawing and submit it to th'a General nailed 6"on-center at the panel edge.llf wall sheathing Firebioeking shall be provided in wood-Frame construction in the following locations, V 12).Unless otherwise noted use 3/4"thick T&G PTS Fir or Advantech plywood subfloor Contractor and owner for final review and approval. is nailed 3"on-center at the panel edg(e to obtain higher shear capacities,nailing requirements for structural adhered with PL400 adhesive and screwed to floor joists.Finished floor to be installed ELECTRICAL NOTES: ' 1). In concealed spaces of stud walls and partitions, including furred spaces,at the ceiling and floor members shall be doubled,or altematte connectors, over subfloor as per manufacture's instructions. such as shear plates,shall be used to imaintain load path. levels. Concealed horizontal furred spaces shall also be fireblocked at Intervals not exceeding 10 1).All electrical to be installed as per N.Y.S.Residential Construction Code. feet. Batts or blankets of mineral or glass fiber shall be allowed as fireblocking in walls constructed 13).All bathroom walls to have 1/2"thick moisture-resistant sheetrock.Garage walls and 2).When wall sheathing is continuous(over connected using parallel rows of studs or staggered studs. ceilings and over furnace to have 518"thick type-x sheetrock.All other parts of building 2).All electrical work shall be approved by a qualified Underwriter. members,the tabulated number of nails shall be permitted to have regular 1/2"sheetrock.All walls to be taped and finished. to be reduced tot-16d nail per foot. 2). At all interconnections between concealed vertical and horizontals aces such as occur at soffits,3).install Smoke detectors and Carbon Monoxide detectors throughout as per section R317 p � 4 drop ceilings and cove ceilings, ` i,j, v �.4.�i''" 14).All roof with a pitch less than 4:12 shall be installed with an Ice&Water barrier or of N.Y.S.Residential Construction Code. . �* approved equal.Flat roofs shall be applied with a Fiberglas base sheet with an EPDM . � � torch down type material over. 3). In concealed spaces between stair stringers at the top and bottom of the run. Enclosed spaces t1�, t, /�!�J`� under stairs shall comply with Section R314.8,N.Y.S. Residential Code. +^" W (t 16).All sill plates and wood in contact with concrete to be pressure treated.Sill plates to ;/ •� DRAWN: MH/MS Ise installed with a foam sill gasket and cop r-tex termite shield or approved equal. 4). At Openings around vents, pipes and ducts at ceiling and floor level, to resist the free assa } lyf + <.y r: .+ � SCALE: 1/4"=1'-T p t� 9 p g� 6 flame and products of combustion, 9 � JOB#• ' "° A 5). For the fireblocking of chimneys and fireplaces,refer to Section Ri001,16. N.Y.S. Residential �dei• ++�'c�„��^' A'* December 12,2006 "'�'��� ,���� SHEET NUMBER: A=7