Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
32568-Z
FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-32697 Date: 10/25/07 THIS CERTIFIES that the building ACCESSORY STORAGE Location of Property: 6619 MAIN RD LAUREL (HOUSE NO.) (STREET) (HAMLET) County Tax Map No. 473889 Section 125 Block 1 Lot 19.7 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated DECEMBER 14, 2006 pursuant to which Building Permit No. 32568-Z dated DECEMBER 14, 2006 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ACCESSORY WAREHOUSE STORAGE BUILDING AS APPLIED FOR & AS PER CONDITIONS OF ZBA #5919 DATED 9/14/06. The certificate is issued to FHV, LLC (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL C10-06-0017 10/25/07 ELECTRICAL CERTIFICATE NO. 115304C 05/07/07 PLUMBERS CERTIFICATION DATED N/A P uthorized Signature Rev. 1/81 --- 73 Y - � 29 Form No.6 ` OC I ;� ZQQ7 U TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL BLDii. DEPT. r �ruiv OF s^t;T6ip�® 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or- topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in-system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: L Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied; the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$25.00, Additions to dwelling$25.00, Alterations to dwelling$25.00, Swimming pool $25.00, Accessory building$25.00, Additions to accessory building$25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy- $.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 Date. �/ 11 7 t New Construct ion: Old or Pre-exi/s�tin Building: (check one) l Location ofProperty: House No. Street Hamlet Owner or Owners of Property: FNP] L-L Suffolk County Tax Map No 1000, Section Block Lot p Subdivision Filed Map. Lot: Permit No. D-56 P-7 Date of Permit. % /6 0$ Applicant: F-111IL .c Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: X (check one) Fee Submitted: 33 l Applican i ature co-E 3.2-� 9 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 32568 Z Date DECEMBER 14, 2006 Permission is hereby granted to: B KELLY FOR FHV PO BOX 1680 SOUTHOLD,NY 11971 for CONSTRUCTION OF AN ACCESSORY WAREHOUSE STORAGE BUILDING PER ZBA #5919, PLANNING BOARD & DOT APPROVALS . at premises located at 6619 MAIN RD MATT/LAUREL County Tax Map No. 473889 Section 125 Block 0001 Lot No. 019 . 007 pursuant to application dated DECEMBER 14 , 2006 and approved by the Building Inspector to expire on JUNE 14, 2008 . Fee $ 681 . 00 Authorized Signature ORIGINAL Rev. 5/8/02 MAILING ADDRESS: PLANNING BOARD MEMBERS rjF SO�,L' P.O. Box 1179 JERILYN B.WOODHOUSE ti0�� yQlo Southold, NY 11971 Chair OFFICE LOCATION: KENNETH L.EDWARDS Town Hall Annex MARTIN H.SIDOR G Q 54375 State Route 25 GEORGE D.SOLOMON: �O Q (cor.Main Rd. &Youngs Ave.) J�PH L_.TOWNSND, t l''COU '� Southold, NY V . Telephone: 631 765-1938 C M S 1 Fax: 631765-3136 PLANNING BOARD OFFICE TOWN OF SOUTHOLD Septeml,,er.•19 2007....'< ;_0 5 - Gerard M. Stankewicz FHV,LLC P.O. Box 1925 Cutchogue,New York 11935 Re: North Fork Custom Audio &Video 6619 Main Road in Mattituck SLIM# : 1000-125-1-19.7 Zoning District: General Business Dear Mr. Stankewicz: At the written request of Gerard Stankewicz date received September 13, 2007 requesting final site plan inspection,Planning Department staff performed a site visit on September 17, 2007. In reference to the above,the Planning Board held a work session on September 17,2007 to discuss the submitted letter, approved site plan and resolution, and the June 20,2007 letter approving changes to the approved site plan. In addition,the Planning Board approves the survey dated September 4,2007 prepared and certified by Nathan Taft Corwin III, L.S. showing the site plan changes as approved by the Planning Board in a letter dated June 20, 2007. This is to inform you that the site plan requirements have been satisfied and include the following items: • All handicap parking stalls, access aisles and signage must comply with New York State Code and ADA requirements. • All outdoor lighting shall be shielded so that the light source is not visible from adjacent properties and roadways. Lighting fixtures shall focus and direct the light in such a manner as to contain the light and glare within property boundaries.All lighting must meet town code requirements. • As per landscape survivability,the applicant agrees to replace any of the landscaping which dies within three (3) years of planting. • As per Town Code §280-127, "any change in use or intensity of use which will affect the characteristics of the site in terms of parking, loading, access, drainage, open space or utilities will require site plan approval'. • As per the final resolution dated November 16, 2006 and the Declaration of Covenants & Restrictions made December 5, 2006,the applicant continues to agree to the future cross easement with the property to the east. North Fork Custom Audio &Video Page Two September 19, 2007 All signs shall meet Southold Town Zoning Codes and shall be subject to approval of the Southold Town Building Inspector. This letter does not condone any changes from the approved site plan and approvals from other agencies if required. Please do not hesitate to contact this office should you have any questions or need anything further. Respectfully yours, Je�BWoodhouse Chairperson Cc: File Building Department Engineering Department Zoning Board of Appeals :'°._ - �i-.•__ �_ h _ •is rYs:.ci,'3 oe','A'�"s= cs,`i;:,�i2^ .cr`S p' 3$•.= r,'•; c..A= - .�_ :`tiynr''<<�ay���•.s` c�r•^b~�: •. Z•�`ss=•� k{+ r-``Z*:4,•:'! .r�••,r•�o t''::�:�Er:.p}3�c ,ti:�.��Fr�.�^r�._E '. £ Tc SC, s- +c •+c 4��sr- ..'�: g s. .t s. s �rS p•� IN`I��•'. '". J�1'4':j:J� 4'•,../�1y♦ '•°�fCC/••i.���i 4•r J/�i p•♦ �♦.P'�i 4�•�5'{'4.:••J IN/O.•.°1fir10y b 1 14°�.��i 4•y��/i4'p:P 1rC/1'4'•:W` O y• qs.•♦ `✓•:0.�� '4•y�J' �••:��r�1 iOG�� M Electrical Inspection Certificate Issue Date Electrical Inspection Service,Inc. Application 5/7/07 375 Dunton Avenue 115304C East Patchogue,New York 11772 (631)286-6642 ----. E --------Issued-To:--I-RLr-LW---------' - ------ --- —--- - --- - ----_.__.------ -------- ------ - Street: 6615 Main Road Village: Mattituck Zip: 11952 Town: Southold Section: Block: Lot: Contractor: G. J..S. Electric(L) (cc) Lic. # 4839-E 9 Was examined and found to be in compliance with the National Electrical Code. �o X❑ Commercial ❑ NV Defects ❑ Pool 'N 1st Floor ❑X Indoor ❑ Basement ❑ Hot Tub ❑ Residential ❑ Det.Garage ❑ Attic ❑ 2nd Floor X❑ Outdoor ❑ Addition ❑ Survey f 4 Switches Receptacles Fixtures GFI Heaters A/C Fans 62 43 Dishwasher WasherlAmps DryerlAmps Oven RangelAmps Microwaves S 4 Furnace Oil Gas Circulators Smoke Detector Bell Transformer r' r Meter Amps Phase UG/OH Jacuni Television CO Detector p S' 'd Bldg. Permit: 32568Z v .Other Equipment 1-125 amp Subpanel/2-Garage Door Opener Recept:/ 1-50 amp Spec. Oulets/2-20 amp Spec. Outlets/1-30 amp Spec. Oulets Hugo S. 96rdi President :> y} .hob b� - ---.- — - ----_ --Rough-Inspection:--03/21f2007 — ----- -:� --- `.- Inspector: John McMahon 111 Final Inspection: 05/02/2007 sj•: Inspector: John McMahon III y b'b ✓•.: ,.; This certificate must not be altered in any manner. Inspectors may be identified by their credentials. (14�•�� ''•4�V11 S 4•. 4.� r it y �9 Pi'•�T ` Ll IT � � t i II � t 7 1I � f 4 T I 1 1 1 �� 1 . 1 I1. r♦ (yam Nil'���f/fl /l { {1 + ♦•�/�+1 P♦♦ . +i/ II/Ylf' 1/41 �11 II+/Y' {/�111 I�Y'1) ��Y 1'V� . �,� {I { /NI� •?5 ����s�.♦�/i//S/p•••p�1P.S♦�/,Ip,p pO l/p..p 1r••.��'Ci/p•••4/fd...♦♦,;`I/..•.p/,;1:LP.•4�i��.4�y1�p.•.♦i�•:Ilp�♦°Illllp.•.�,�:a0.•.♦ilU:lO•'•h41S�d ir1�1i1..0♦♦�11�..♦�111��.O y�61:1 p•.♦i N� •.:�IIIr000♦,{IIIJ�,�O� 4.,`%:•'•ree'fis:•,•s'..i•':•,i4.'e'•'•'.c ❖••r>�'•:'f4^i%:•b'-i.•'❖••r<-Vie•❖°•:_-.e,�y!'/•.E_i'❖��ti i•:fr"G4•'i•'Y�1:%:•':2_e!:dre..EC'•:•' �iv�''ti�a��=•'Y_'�•,•,�:;-f;�rs�;.•fr•.<+t,•i�3-�•,�,...r y.,.�,in ..,y 1 E.•=- -: E-�=- �i£= ��._ osy_ ���.? _7�_ tea.- �,.._ ..r- -`•--- �.� �Y:.. �:.._ _�•'- •'- i-r �.- �_ ��.:� ..- �..y ti. - 1�- �Y - Cam- �- ._� -- �� - - �L �^� �1.. 4•��1 _.•y�� � �� APPEALS BOARD MEMBERS *OF SU(/r�, Mailing Address: Ruth D.,Oliva,Chairwoman O� Ql Southold Town Hall 53095 Main Road•P.O.Box 1179 Gerard P. Goehringer � � Southold,NY 11971-0959 James Dinizio,Jr. N Office Location: Michael A. Simon � Town Annex/First Floor,North Fork Bank Leslie Kanes Weisman Cpi'JNM 54375 Main Road(at Youngs Avenue) Southold,NY 11971 _ http://southoldtown.northfork.net ZONING BOARD OF APPEALS TOWN OF SOUTHOLD ` SOT 8 2006 { q Tel. (631)765-1809•Fax(631)765-9064 SOOT➢O .) FINDINGS, DELIBERATIONS AND DETERMINATION MEETING HELD SEPTEMBER 14, 2006 ZB File No. 5919—FHV, LLC Property Location: 6619 Route 25, Laurel CTM 125-1-19.7 SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this application and determines that this review falls under the Type II category of the State's List of Actions, without an adverse effect on the environment if the project is implemented as planned. PROPERTY FACTS/DESCRIPTION: The applicant's 1.1645 acre parcel is improved with two (2) existing one story buildings, as shown on the plan prepared by S.L. Maresca Associates, Consulting Engineers, dated 2- 24-03, updated 3-29-03 with landscaping details. BASIS OF APPLICATION: Notice of Disapproval issued by the Building Inspector on January 27, 2006 for the reason that the proposed accessory building construction would be in violation of a condition related to the Building Inspector's March 15, 1990 Notice of Disapproval issued for this property, and a Variance determination with Conditions under ZBA Appeal No. 3931, regarding a request for a minimum of 30,000 square feet of land area per use under Zoning Code Section 100-102. Zone District: B General Business. FINDINGS OF FACT The Zoning Board of Appeals held a public hearing on this application on August 31, 2006, at which time written and oral evidence were presented. Based upon all testimony, documentation, personal inspection of the property, and other evidence, the Zoning Board finds the following facts to be true and relevant: AREA VARIANCE RELIEF REQUESTED: On May 30, 1990, the Board of Appeals granted a variance (Appeal No. 3931) to allow a second business use in the B Zone on a property less than 60,000 square feet, with the condition that building #2, used as an electrical contractor business and located in the rear yard of said parcel, would not exceed the 35 x 50 feet as shown on a survey dated Dec 22, 2987 by R. Van Tuyl, The owner/applicant proposes to build a 42 x 16 x 60 foot Morton Building to serve as an accessory warehouse for the storage of vehicles and supplies related to the operation of the two principal businesses on the subject premises, which the Building Inspector states would be a violation of a condition accepted and issued under Appeal No. 3931. REASONS FOR BOARD ACTION: On the basis of testimony presented, materials submitted and personal inspections,the Board makes the following findings: Page 2—September 14,2006 ZB File No.5919—FHV, LLC CTM No. 125-1-19.7 1. Grant of the variance will not produce an undesirable change in the character of the neighborhood or a detriment to nearby properties. The application has received site plan approval from the Planning Board and approval from the Architectural Review Committee. The businesses to the west (a car wash) and the east (Tyler Electric) are heavily screened from views of the subject property by mature evergreens and hedgerow. The proposed accessory storage building (#3) is sited far back from.Route 25 and screened by the existing principal building to the north (#1). The site plan dated 2/24/06 shows a row of evergreens along the south edge of the proposed accessory structure to further screen it from views from Route 25. The existing two businesses on the subject property, North Fork Custom Audio/Video, and GJS Electric, (building #1 and building#2 respectively on the site plan submitted and dated 2/24/06) are similar to other business uses in the area. 2. The benefit sought by the applicant cannot be achieved by some method, feasible for the applicant to pursue, other than the relief requested. The Building Inspector states that an accessory structure cannot be built in connection with a use related to the second business on the subject premises without a variance from the Board of Appeals. The proposed accessory warehouse does not constitute an expansion of either of the two existing business. 3. The variance granted herein is substantial. The third proposed accessory structure to be used as a warehouse is 2,250 square feet, each of the existing principal buildings (#1 and #2) measure 1,785 square feet each. However, the additional proposed accessory structure does not exceed the allowable lot converge on the subject property. 4. The alleged difficulty has been self-created because the owner/applicant chose to build an accessory storage structure that will be used for storage for both of the two businesses on the subject premises in violation of a condition set forth in ZBA Appeal No. 3931 dated May 30, 1990. 5. No evidence has been submitted to suggest that the proposed additions will have an adverse impact on physical or environmental conditions in the neighborhood. Potential ground water runoff toward Route 25 on this north/south sloping property will be controlled by proper drainage and infrastructure as shown on the site plan dated 2/24/06. 6. Grant of the requested variance is the minimum action necessary and adequate to enable the applicant to enjoy the benefit of a new accessory building to a second business on the subject property, while preserving and protecting the character of the neighborhood and the health, safety and welfare of the community. RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing test under New York Town Law 267713, motion was offered by Member Weisman, seconded by Chairwoman Oliva, and duly carried, to GRANT the variance as applied for, as shown on Drainage and Site Plan dated February 24, 2006 by S. L. Maresca Associates, Consulting Engineers, and elevation diagram prepared by Allied Design Architectural & Engineering Group, P.C. subject to the following condition: Ti a proposed�acces g strupcture be_used only for�nirehouserage and not for the expansion ofof e 9f the-two existin n rid al-business-uses-on-the-subject.premise Any deviation from the variance given such as extensions, or demolitions which are not shown on the applicant's diagrams or survey site maps,are not authorized under this application when involving nonconformities under the zoning code. This action does not authorize or condone any current or future use, setback or other feature of the subject property that may violate the Zoning Code,other than such uses,setbacks and other features as are expressly addressed in this action. The Board reserves the right to substitute a similar design that is de minimis in nature for an alteration that does not Page 3—September 14,2006 } ZB File No.5919—FHV, LLC CTM No. 125-1-19.7 increase the degree of nonconformity. Vote of the Board: Ayes: Members Oliva (Chairwoman), Goehringer, and Weisman. (Absent were: Members Dinizio and Simon.) This Resolution was (�/3f\-0).d dopted & rqa—Ir" Ruth D. Oliva ) 9/.tpf/06 Approved for Filing MAILING ADDRESS: PLANNING BOARD MEMBERS P.O.Box 1179 JF*,ILYN B.WOODHOUSE ®��Of SO(/,y�l Southold,NY 11971 Chair � � OFFICE LOCATION: KENNETH L.EDWARDS Town Hall Annex MARTIN H.SIDOR G 54375 State Route 25 GEORGE D.SOLOMON �� ^��� (cor.Main Rd.&Youngs Ave.) JOSEPH L.TOWNSEND IyCOWN,� Southold,NY Telephone: 631 765-193 8 w 3� ax:631 765-3136 P1Jh1\1\i TO _'� September 19,2007 � Gerard M.Stankewicz ; P 4 c, 2 � 2007 FHV,LLC � _ , `• P.O.Box 1A�5/o�9v� ; �.•u,.. ; Cutchogue,New York 11935 _ _11...•.- --- -f` Re: North Fork Custom Audio &Video 6619 Main Road in Mattituck SCTM#: 1000-125-1-19.7 Zoning District: General Business Dear Mr.Stankewicz: - At the written request of Gerard Stankewicz date received September 13,2007 requesting final site plan inspection,Planning Department staff performed a site visit on September 17,2007. In reference to the above,the Planning Board held a work session on September 17,2007 to discuss the submitted letter, approved site plan and resolution,and the June 20,2007 letter approving changes to the approved site plan. In addition,the Planning Board approves the survey dated September 4,2007 prepared and certified by Nathan Taft Corwin III,L.S.showing the site plan changes as approved by the Planning Board in a letter dated June 20,2007. This is to inform you that the site plan requirements have been satisfied and include the following items: • All handicap parking stalls,access aisles and signage must comply with New York State Code and ADA requirements. • All outdoor lighting shall be shielded so that the light source is not visible from adjacent properties and roadways.Lighting fixtures shall focus and direct the light in such a manner as to contain the light and glare within property boundaries.All lighting must meet town code requirements. • As per landscape survivability,the applicant agrees to replace any of the landscaping which dies within three (3) years of planting. • As per Town Code S280-127,"any change in use or intensity of use which will affect the characteristics of the site in terms of parking,loading,access,drainage,open space or utilities will,require site plan approval". • As per the final resolution dated November 16,2006 and the Declaration of Covenants & Restrictions made December 5,2006,the applicant continues to agree to the future cross easement with the property to the east. `1,16A Fork Custom Audio&Video Page Two September 19,2007 • All signs shall meet Southold Town Zoning Codes and shall be subject to approval of the Southold Town Building Inspector. This letter does not condone any changes from the approved site plan and approvals from other agencies if required. Please do not hesitate to contact this office should you have any questions or need anything further. Respectfully yours, Je�BWoodhouse Chairperson Cc: File Building Department Engineering Department Zoning Board of Appeals MV,LW P.O.Box 1295 Cutchogue,N.Y.11935 Tel/Fax 631-734-6429 August 21, 2007 �Tn . , ��A- - Southold Town Building Department f ; . Atli.: Mr. George Gillen g Re: Building Permit# 32568Z Dear Mr. Gillen, Attached are: 1. Insulation Certificate from the engineer 2. Interior room certification from engineer 3. Copy of truss placard that will be installed this week. I believe the only item left as per last inspection that will be required is the Building Location, which will be on the final survey, which will be submitted with three weeks, as it has already been ordered. I would appreciate it if you could take the time to review the file so that this is all I will need to apply for the final Certificate of Occupancy. I can be reached at 63- 786-1809. Thank you. Sincerely, foodlWStarke i c z Managing Agent ,s.' "^a, /y r',� �, l., ��4� \ +` \ �� ,` `. � \� i j ,1 - �\ 1 �1 _ � �� i� `� i i f i _ , `, -, '� -, ,� •, .,� `� �•., ,, ,� ..,� �.` l l MES J. DEERKOSKI, P.E. 260 Deer Drive Mattituck,N.Y. 11952 (631) 298-7116 Date: Au 2607 To: Town of Southold Building Dept. Re: Interior room floor Framing Inspection Main Rd Mattituck,NY 11952 Permit#32568 To Whom It May Concern: After an inspection was preformed on the above mentioned interior room floor system, it is deemed that all work performed was completed as per submitted plans and meets all state and local codes. Any other questions please call. Of .; cerely 1 � James J. Deer Allied Design Architectural:& Engineering:Group9 P.C., . July 19,,2007 j i i � .I Town of Southold Building Department Southold NY RE:FHV.LLC Project 42°w x 601: Heated Warehouse- " -:.6615 Main Road 1Vlattituck,NY , MBI Job#128=0765 _ _ . .Dear Sirs: I am' mn iri'g to eonfirin that the ceiling insulation,having an'R°value.of 19, was.installed according to my plans dated 01 19-07 and to my specified requirements. Yourstrul'y, Aflied,Desigri Architectural and Engineering Group,--P.C. Ronald on,P .. . Presi yO ��,► * ®� o # 100 S:Pershing. P.O.Box 110 Morton,IL'61550 j: 309.263.4105 i _ Allied De"' Architectural 8�En ineerin ' ro p, P.C: May 7, 2007 Town,of°Southold Building Dept 4 ;: S61!thold,,NY LLC/Charles Salice . 42'W x 16'H x 60'L . Storage Building Mattituck;:NY 1V1BI#`_12$,0765 DearlSirs Please.find"enclosed truss de -for the truss thatrwas`used for this job —I also writing to confirm:and advise that the:footings and foundation were o rved to have"been installed in,accordance to-my,plans dated O 1=19, 07. M( ' t 1 Footings`were placed;4'10"bel"ow grade and were drilled the 1� , diameter specified on the plans 2:) 11/4"x 11/4"x 14 Ga'columnstilts were,attached to each column corner with(3):'0 148" dia.,X 2"..stainless nails: 3' ): Concrete for each footing was.placed in accordance with the plans = ,Yours truly, Allied' A.&E Group;PC Roria is : sgv6 ' - s .' Pres o$ , o.. r t� p g1�tAl't��II.GY550�� p 309b3:2 4�5 ems : t i Truss Design Load - 300 pif LUMBER SPEC I FKAT I ONS Top Chord (3) i2X10 SYP N❑ . 1 KD19 ;1 , 7E6 Regid Truss Load - 3'L �)sf at `j ,rji OC. _ �4p pff I c'i I CI I01- d ( 1 , 2) 2X 1 0 SYP MSR 1950 1 , 5E6 I.c,wer (".fiord 2X4/2X6 SYP MSR 1950 1 . 5E6 11ek•)s 2X4 SYP N0 , 1 KD19 1 . 7E6 LOADS 1 TRUSS PLATE DATA TCLL 2(o psf- (ANSI/TPI I-1995> Load dura-t; Ion fac-tor = 1 15 20 GA. 18 GA. TCDL 4- psf AA 86 psi 108 psi LCDL 2 psf Lateral EA 87 psi lot PSI MEMBER FORCE TABLE Design Value AE 59 Psi 43 psi — EE 63 Psi 46 Psi Member Forces Member Stresses Tensile Value 0° 403 pli 610pIi Bending AxIat Bending Axial 90° 403 p1. 610 pli Member CSI ( In- (bs) ( (bs) (psi ) (psi ) Shear Va tue 01 275 p l i 410 p t i -TC'1 . 676 9669 . -13616 . - 452 , 0 -981 . 3 + ; 00 315 ptI 361 pt 60 TC2 . 770 14918 . -13184 . 697 . 4 -950 . 2 90. 276 pt i 410 pli TC3 . 861 -13031 , -1 1579 -609 . 2 -834 , 5 120° 261 pli 363 pli ptl 3 pl1 LC1 , 858 11490 , 12913 , 567 , 4 956 . 5 150. 306 pt 1 428 pl i LC2 . 792 11490 . 1 1514 , 567 , 4 852 . 9 IOxIS P1. LC3 . 423 452 . 8826 , 22 . 3 653 . 8 W1 160 0 . -1273 , 0 -242 . 4 B W2 . 433 0 . -2756 , A -525 , 0 C.. i Z'IoxB W3 . 213 0 . 1353 , . 0 257 . 7 TC3 W4 . 519 0 . 3289 , 10 626 . 4 11x13 PI. Zkl0x16. ,/?" tytq r� . W1 2x4 TC2 1ATea �(/ • •��.. 12 IL V W2 W3 ) 4 ISO PI. 18 Co. h • 0 3x5 PI. TCI 13AS PI. 18 Ca. ,0, �' Ilxl WI • • ' I600 PI PI. W.3 18 Go. 13xS PI. 15x5 PI. IB Ga. :i i' 18 Co. 9x9 PI. ;eiyN.i i..li �- ( • • 0 Eats: LC-3 P• i!E LC2 1�' WIT h iilt IS_1/2• In - - — --- Chord 2xfi LCI I11 (b rh1:BEN A! (:f 1l IERI IIIE 5'0— - / I4" / 12'2-13/I6` 4x5 Pis. T}p. 20'10-1/2- —0i, } Os Truss Reaction ) 6193 , 750 bs , _ 4.21-L COMM. SC TRUSS 42 -- Morton Buildings NYSDOT TRANSPORTATION MAINTENANCE RESIDENCY 03 1900 COUNTY ROAD 58 M E M O R A:N D U M . RIVERHEAD, NY 11901 DEPARTMENT OF TRANSPORTATION— tel(631)727-1731 N EE fax(631)727-6645 7. 4 TO: Town of Southold + Town Hall µ SEP 14 2001 PO Box 1179 Southold, N.Y. 11971 ATTENTION: Building Dept. - Michael J. Verity a.r;.cc.re;tFte§':�'1'io'fr:wcxr,P+c3::fi::�n-rtR. FROM: Kevin E. Matthaei , Eastern Suffolk Permit Engineer SUBJECT: NYSDOT Highway Work Permit#10-04-0509. For FHV, LLC to "construct and permanently maintain" a commercial access on the north side of Route 25 at mile marker 1522, SCTL# 1000-125-1- 19.7 DATE: September 13, 2007 The above mentioned New York State Highway work Permit has been completed as required. There are no holds or restrictions on this permit. If you have any questions or concerns, please call me at (631)727-1731. 'M ------ Sincerely, 1101 r �` p 14 200 Kevin E. Matthaei ��,;;;. DEFT. Eastern Suffolk Permit Engineer T V F SQJTAot D fg�SDOT 516 727-1731 FAX 516 727-6645 Region 10 Residency 03 Suffolk East 1900 Rte. 58, Riverhead, NY 11901 OF SOplyolo Z- 'F cDUNiY,�c� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [`FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: / '^ o JJ i -uk �J DATE INSPECTOR OF SOUryo�o 3 7- TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND KINSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: cola— o DATE INSPECTOR Of SOpTyolo IroutNmvl ' TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING P FINAL ] FIREPLACEA CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: f,,&ewv�� � DATE / INSPECTOR ho��pF SOUTyolo cOUNi'i,� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: DATE INSPECTOR FIELD INSPECTION REPORT 7DATE I COMMENTS FOUNDATION(1ST) ------------------------------------- (U FOUNDATION(2ND) z ROUGH FRAMING& PLUMBING — y INSULATION PER N.Y. — H ' STATE ENERGY CODE \ a VL r FINAL ' } CAM / V— Y / Ar -® ADDITIONAL&OMMENTS (01 i5 2tv4 uAd,,,L cam- aj 7 � z rn ok Ae- 1 H 0 CK) z x � d b H TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL,, . Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey www. northfork.net/Southold/ PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees Examined /a�/ ,20 o Contact: Approved 1 / ,2 Mail to: Disapproved a/c Phone: Expiration Zlla ,20 0 fe F3uTdin Inspector •; ; , � i i � APPLICATION FOR BUILDING PERMIT � Date � — IC , 20641- --- -- - - --- INSTRUCTIONS .. IIIJLD a. "Phis pp ication 1VIIIS The completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and-of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing,the extension of the permit for an addition six months.Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws,Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code,and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. '(Si`gr6d of aapppl' ant or n me,if a corporation) 7,Z JSr ?C LA (Mailing address of applicant) U 1• l--r # 1-4 Cy-rGFALZ-;(JL OLA State whether applicant is owner, less e, agent, chitect, engineer, general contractor, electrician, plumber or builder Name of owner of premis _ (As on the tax ro or atie5t e �— If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. UA Electricians License NoALA Other Trade's License No.AA tom€ and on which proposed work will be done: 4b I 0007'0- House Number Street Hamlet - County Tax Map No. 1000 Section 17- Block l Lof,, , Subdivision Filed Map No. •: -.Lot. A (Name) 2. State existing use and occupancy of premises and intended use arld occupancy of proposed construction: a. Existing use and occupancy- b. Intended use and occupancy //�/�� 3. Nature of work(check which applicable): New Building Addition Alteration Repair 01 1 Removal Demolition Other Work oG (Description) 4. Estimated Cos Fee (To be paid on filing this application) 5. If dwelling, number of dwelling fu n ids . Number of dwelling units on each floor If garage, number of cars ��„/� 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dim structures, if any:.Front ear Depth Height u s Dimensions of s ructure with alterations or additions: Front De Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height 04 ` (c," Number of Stories 0KAL 9. Size of lot: Front 22� Rear. 171 S Depth F 10. Date of Purchase — Name of Former Owner Mom' 11. Zone or use district in which premises are situated •---���� J 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES )( NO Will excess fill be removed from premises? YES NO�<— 14. Names of Owner ofTremisesAddress Phone No. Name of Architect 4.,.. �� AddressCQ—j& WQk- Phone No 7aA —14b.10 Name of Contractor NkM7rOM F:;L" AddressCP-X,I��U�Phone No. -44666 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO V * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO—)� * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTY OF ) being duly sworn, deposes and says'that(s)he is the applicant (Name of individual signing contract) above named, (S)He is the 1&4k4`( (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to befo m 's -Z of ca S' 20 C' Notary Pub 'c ignat e of Ap nt ROBE . Sta e�of New York Notary alified in Suffolk County No.01SC47250 Term Expires May: FR,LLC P.O.Box 1295 CutchoM N.Y.11935 Phone 631-734-6429 Fax 631-734-6429 October 15, 2007 Southold Town Building Department Attn.: Mr. George Gillen Re: Building Permit#32568Z Dear Mr. Gillen, As per last inspection, the following items were needed for the final C of O. 1. Insulation Certificate from engineer (This has been submitted and is in the file) 2. Interior room certification from engineer (This has been submitted and is in the file) 3. Copy of Site Plan approval (This has been submitted and is in the file) 4. Final Survey— showing building location (This has been submitted and is in the file) 5. Truss placards installed (Installed and visible upon final inspection) 6. Health Department approval (Final test paperwork delivered to Health Department 10/17/07; will be picking it up within 7 days or sooner) I believe this should complete everything on the list. If there is anything else of concern, please let me know. Thank you. I Sincerely, 4 erard M. aewicz Managing Agent JAN-23-2006 MON 10:29 AM FAX NO, 212 271 8785 P. 01 FHV LLC . N 0 R T H F 0 R K DEAR Town of SOUTHOLD, building department 1/22/06 For the propsed new Morton storage building at 6615 Main Road , Mattituck. The site of G]S Electric . The building will only be used for additional warehouse and storage space for GIS Electric , As needed for our expanding bussiness . Thank You, for your consideration CHARLES V. SALICE OWNER /MANAGING PARTNER r P.O. BOX 1295 CUTCHOGUE NEW YORK 11935 JAN 23,2006 10:23A 212 271 8785 page 1 MAILING ADDRESS: PLkW-UNG BOARD MEMBERS ��0� so Southold,Box 1179 11971 JERILYN B.WOODHOUSE �® l� Chair OFFICE LOCATION: KENNETH L.EDWAR.DS Town Hall Annex MARTIN H.SIDOR �� 54375 State Route 25 GEORGE D.SOLOMON 0��. (cor.Main Rd.&Youngs Ave.) JOSEPH L.TOWNSEND MUMN Southold,NY Telephone:631 765-1938 Fax: 631 765-3136 PLANNING BOARD OFFICE TOWN OF SOUTHOLD June 20,2007 ----- Gerard K Stankewicz - - ---� FHV,LLC n� P.O.Box 1925 JUL 18 20 Cutchogue,New York 11935 BLDi- DEP T WN QF SC`L'THOLD i Re: North Fork Custom Audio &Video 6619 Main Road in Mattituck SCTM#: 1000-125-1-19.7 Zoning District: General Business Dear Mr. Stankewicz: The Planning Board,at their work session on Monday,June 4,2007,reviewed your request,dated June 1, 2007(attached),and approves the following changes to the approved site plan: ■ Rearranging the proposed handicap parking space to allow for handicap access to the existing 51'x 35'building(building#2). All handicap parking stalls and access aisles must complywith New York State Code and ADA requirements. ■ The installation of a concrete wall to the north of the,proposed 42'x 60'building. The proposed wall will not require additional bumpers for parking. ■ The shift in the proposed Belgium block lined stone driveway to the east to allow for better access to the rear portion of the site. The Planning Board approves this shift in the driveway provided that: o The size (square feet) of the driveway will remain the same. o The vegetative border between the subject parcel and the parcel to the east will be maintained. o The area to the west of the proposed driveway will be maintained with grass. ■ Moving the dumpster from the proposed location(near building#1)to the northern portion of the site where it will not be visible from the road. The Planning Board approves the relocation of the dumpster and reserves the right for further comment at the time of final site plan inspection to ensure the dumpster is adequately screened. ■ Extend the proposed Belgium block curbing and add a small stacking wall extending from the proposed gravel driveway north of existing building#1. ■ Raise the top cover of 2 drywells PW7&DW8) approximately 6 inches. The Planning Board and Town Engineer approves the raising of these covers and the installation of a 6" trench drain north of the concrete apron provided that written approval from NYSDOT is obtained prior to construction and all water is adequately maintained on site. Written approval from NYSDOT should be submitted to this office for the file. North Fork Custom Audio &Video Page Two June 20,2007 All construction must complywith Town Code. This letter will serve as permission from the Planning Board for these proposed changes. Once all site work is complete please submit a request in writing for a final site inspection for site plan satisfaction. As referenced in your letter,please submit three (3) copies of the as-built site plan along with your request. This letter does not condone any other site plan changes and or approvals from other agencies if required. Please do not hesitate to contact this office should you have any questions or need anything further. Sincerely, 8e, .,� —?,,, . Jerliyn B.Woodhouse Chairperson Cc: File James A.Richter,Town Engineer Michael J.Verity,Chief Building Inspector Gary Salice,FHV,UC Enc: June 1,2007 letter from Gerard M.Stankewicz t -.1 " ~ • FNV,UC P.O.Box 1925 Cutchogue,N.Y.11935 Tell Fax 631-734-6429 June 1, 2007 Southold Town Amy Ford, Bruno Semon ' Re:6619 Main Road,Mattituck Dear Sirs, r Attached is a copy of the site plan with the following changes requested: A. Handicap Space: Enlarging it slightly and sliding it.south so that it enables access to the door. It would attach to the existing apron so that the accessibility to the door is enabled. As it is presently shown, there would be gravel between the handicap space and the doorway, which would defeat the purpose. B. A concrete retaining wall has been added just north of the new Morton building, with rebar and gussets, to lessen the steepness of the grade and direct the water runoff more directly to the drain. The parking has not been compromised, as there is still more than 22 feet between the front and rear parking spaces. The wall extends above the parking area approximately twelve inches, is away from the building six feet, and there is no possibility of a vehicle being able to come in contact with the building. In conjunction with this, since the walls elevates over grade level approximately 8 inches, it was suggested to us that the wall act as the curb stop in the parking areas, and that the curb stops for the automobiles would not be necessary. C. We would like to shift over the Belgian block border to the east as drawn in, as Ahe way it is proposed.no_w,-would lead into.the_pre-exasting_fence where there is no opening. The amount of grass would remain the same, as the width of the driveway would remain the same. It is just to shift the connection between the lower and the upper parking areas to the east. D. We would like to raise the top cover of two drywells—DW7 and DW8 approximately 6 inches. This is because the way the drywells are now set to grade, coordinating with the state codes with the entrance, the grade does not allow for trucks with a trailer to enter. The grade is basically the same, and if there is a concern regarding the lower drywell taking on more water, all of the drywells are connected to each other and will be taking on the same amount of water. We are also checking with the state to see if we can add a 6"trench drain at the entrance, where the concrete apron ends, tying it in with the existing drywells there, to enhance the approved drainage plan. Page 2 E. Lastly, where the dumpster is shown on the lower level, we would like to move that to an upper area where it will not be visible from the road. That area where it was proposed to be, we would like to extend, as shown on the plan, the Belgian block, and add a little landscaping. This would be in the form of a small stacking wall. We believe it will coordinate with the existing landscape and grade better, and be more pleasing aesthetically. If there are any questions or problems with the above, I would be happy to explain -all-in-more-detail,-and would appreeiate any--suggestions in-regards to the- above.All items would be shown on the final survey submitted to the town when applying for the final C of O. Thank you. Sincerely, J Gerard M. Stanke4c'z Managing Agent MAILING ADDRESS: PLANNING BOARD MEMBERS *QF SO P.O.Box 1179 JERILYN B.WOODHOUSE h�V'` yplo Southold, NY 11971 Chair OFFICE LOCATION: KENNETH L.EDWARDS CA Town Hall Annex MARTIN H.SIDOR G @ 54375 State Route 25 GEORGE D.SOLOMON ��l �� (cor.Main Rd. &Youngs Ave.) �JOSEPH L:TO ` Cum� Southold, NY R n a Telephone: 631 765-1938 20Oo Fax: 631 765-3136 �� PLANNING BOARD OFFICE TOWN OF SOUTHOLD T 1l 3CJ T HOLD ovember 14, 2006 William S. Kelly 22355 Cox Lane - Unit#4 Cutchogue, NY 11935 Re: Proposed amended site plan for North Fork Custom Audio & Video Located on the n/s/o New York State Road 25, approximately 250' w/o Laurel Trail known as 6619 Main Road in Mattituck SCTM #: 1000-125-1-19.7 Zone: General Business (B) Dear Mr. Kelly: The Southold Town Planning Board, at a meeting held on Monday,, November 13, 2006, adopted the following resolutions: The final public hearing was closed. WHEREAS, this amended site plan is for the proposed new construction of a 2,520 square foot 1 story building for warehouse/storage which includes a site plan change in parking to 26 required spaces, 29 provided on 1.1645 acres in the General Business Zone located on the n/s/o New York State Road 25, approximately 250' w/o Laurel Trail known as 6619 Main Road in Mattituck. SCTM #: 1000-125-1-19.7; and WHEREAS, FHV, LLC is the owner of the property located on the n/s%o New York State Road 25, approximately 250' w/o Laurel Trail known as 6619 Main Road in Mattituck; and WHEREAS, on April 9, 1984, the Southold Town Planning Board granted site plan approval for a 35' x 50' building for a tree service building; and WHEREAS, on March 9, 1987 the Southold Town Planning Board granted are d sate plan approval for "a 35' x 50' storage building accessory to the existing building"; and WHEREAS, on December 9, 1991, the Southold Town Planning Board granted an amended site plan approval for a change,in use from Shamrock Tree Company to Acrylic Duck Marine Canvas; and WHEREAS, on October 4, 2004 the Southold Town Planning Board granted conditional final approval for the alteration of an existing 1,785 sq. ft. building on the site plans prepared and certified by John C. Ehlers, Surveyor, dated June 13, 2004 and last revised September 21, 2004 subject to final approval from the New York State Department of Transportation; and FHV, LLC - North Fork Custom Audio & Video Page Two November 14, 2006 WHEREAS, on December 14, 2004, the Southold Town Planning Board granted final approval for an amended site plan for the alteration of an existing 1,785 sq. ft. building on the site plan prepared and certified by John C. Ehlers, Surveyor, dated June 13, 2004 and last revised September 21, 2004; and WHEREAS, on March 29, 2006, the agent, William S. Kelly working for the applicant, North Fork Custom Audio & Video, submitted an amended site plan application for approval; and WHEREAS, on May 4, 2006, the Architectural Review Committee reviewed the architectural drawings and associated site plan materials and approved the project as submitted; and WHEREAS, on May 30, 2006, the Building Department amended the Notice of Disapproval to address the previously issued ZBA decision appeal #3931 which stated "...a second business that will not exceed 35 X 50 ft..."; and WHEREAS, on May 31, 2006, the Southold Town Engineer reviewed the proposed site plan and requested further information; and WHEREAS, on June 14, 2006, the Mattituck Fire District responded that no additional water supply is required and that all drives and roads meet Town requirements; and WHEREAS, on June 21, 2006, the Suffolk County Department of Planning responded after review and determined this matter is for "local determination as there appears to be no significant county- wide or inter-community impact(s)" and the Planning Board accepts this pursuant to 239L & M General Municipal Law; and WHEREAS, on June 22, 2006, New York State Department of Transportation responded that the previously issued Highway Work Permit#10-04-0509 expired on June 1, 2005 and a permit extension would be required; and WHEREAS, on July 7, 2006, the agent was forwarded a copy of the New York State Department of Transportation letter dated June 22, 2006; and WHEREAS, on September 12, 2006, the Southold Town Planning Board, acting under the State Environmental Quality Review Act (6 NYCRR), Part 617.5 c, makes a determination that the proposed action is a Type II and not subject to review; and WHEREAS, on September 14, 2006, the Southold Town Zoning Board of Appeals granted an area Mari r Anneal #5 to build "a 42 x=16 x 60 ft Morton building to serve as an accessory warehouse for the storage of vehicles and supplies related to the operation of the two principal businesses" and with the following condition: 1. That the proposed accessory structure be used only for warehouse storage and not for the expansion of either of the two existing principal business uses on the subject premises; and FHV, LLC - North Fork Custom Audio & Video Page Three November 14, 2006 WHEREAS, on September 20, 2006, the Suffolk County Water Authority responded after review that there is an existing water main and one (1) inch service serving the above captioned property from Main Road; and WHEREAS, on October 23, 2006, the Southold Town Building Inspector reviewed and certified the site plan for a "Accessory Warehouse Storage" use; and WHEREAS, on October 25, 2006, the Southold Town Engineer reviewed the revised site plan materials and replied that all items have been addressed in a satisfactory manner; and WHEREAS, the Southold Town Planning Board, pursuant to Chapter 58, Notice of Public Hearing, has received affidavits that the applicant has complied with the notification provisions; and WHEREAS, the following items shall be required: 1. The applicant agrees to be bound by all of the requirements in the Declaration of Covenants & Restrictions for a cross access easement agreement date received November 13, 2006 pending review and approval from the Town Attorney and the Southold Town Planning Board. 2. All outdoor lighting shall be shielded so that the light source is not visible from adjacent properties and roadways. Lighting fixtures shall focus and direct the light in such a manner as to contain the light and glare within property boundaries. The lighting must meet town code requirements. XAll signs shall meet Southold Town Zoning Codes and shall be subject to approval of the Southold Town Building Inspector. 4. As per the landscape survivability guarantee, the applicant agrees to replace any of the landscaping which dies within three (3) years of planting; be it therefore RESOLVED, that the Southold Town Planning Board has reviewed the proposed action under the policies of the Town of Southold Local Waterfront Revitalization Program and has determined that the action is consistent with the Policy Standards in the July 31, 2006 memo prepared by the LWRP Coordinator; and be it further RESOLVED, that pursuant to Southold Town Code 100-254 Part I, the applicant agrees to incorporate all the requirements, comments, and recommendations of each reviewing agency as referenned abmie and as c2ted on the site -!an nd corresponding attaaGhme Its; and be it further RESOLVED, that the Southold Town Planning Board grant approval on the site plan drawing D-1 & D-2 prepared and certified by Steven L. Maresca dated February 24, 2006 and last revised November 9, 2006 and the construction plans G1 and S1-S6 prepared and certified by Ronald L. Sutton and authorize the Chairperson to endorse the site plans with the following conditions: 1. Pending final approval of the Declaration of Covenants & Restrictions by the Southold Town Planning Board, the applicant agrees to file and record Declaration of Covenants & Restrictions for a cross access agreement in the Office of the Suffolk County Clerk within sixty FHV, LLC - North Fork Custom Audio & Video Page Four November 14, 2006 (60) days of site plan approval. A copy of the filed Declaration of Covenants & Restrictions for a cross access agreement must be submitted to the Southold Town Planning Department within thirty (30) days of receipt. If the applicant/agent/owner fails to adhere to this requirement within the prescribed time periods, this approval shall become null and void. 2. The site plan approval requires that all work proposed on the site plan shall be completed within three (3) years from the date of this resolution. 3. If necessary, the applicant/agent/owner shall obtain certification from a design professional for the existing septic system or approval from Suffolk County Department of Health Services for the approved construction. This approval must be to the satisfaction of the Southold Town Building Department. If the septic approval changes from the approved site plan, the Planning Board reserves the right to the review of a new site plan application. 4. Prior to the request for the Certificate of Occupancy, the owner or authorized agent must request, in writing, the said Building Inspector and the Planning Board to perform an on-site inspection to find the site improvements are in conformity with the approved amended site plan. 5. Prior to the request for an on-site inspection, the applicant/agent/owner must submit a copy of all required approvals from any necessary agencies to the Southold Town Planning Department. 6. The applicant agrees to obtain a valid New York State Department of Transportation Highway Work Permit as required in their letter dated June 22, 2006 within sixty (60) days of site plan approval. A copy of this approval and plan must be submitted to the Southold Town Planning Department within thirty (30) days of receipt. All conditions of New York State Department of Transportation Highway work permit#10-04-0509 must be completed. Any changes in the approved permit must be submitted to this office for review. If such approval varies from this approved site plan, the Planning Board reserves the right to review a new site plan. 7. If the as-built site improvements vary from the approved amended site plan, the Planning Board reserves the right to request a certified as-built site plan detailing all the changes. 8. Any changes from the approved site plan shall require Planning Board approval, and any such changes without Planning Board approval will be subject to referral to the Town Attorney's Office for possible legal action. The Planning Board will issue a final site plan approval in the form of a letter following a site inspection and at the time the site improvements are found to be in conformance with the approved site plan. A copy of the approved amended site plan is enclosed for your records. As per the Town Code, one copy each will be distributed to the Building Department, Town Engineer/Highway Department and Zoning Board of Appeals. FHV, LLC - North Fork Custom Audio & Video Page Five November 14, 2006 If you have any questions regarding the above, please contact this office. Very truly yours, N Jerilyn B. Woodhouse Chairperson Enc. cc: Southold Town Building Department Southold Town Engineer Southold Town Zoning Board of Appeals New York State Department of Transportation (Resolution & approved plan) Abigail A. Wickham, Esq. F 4 ITgbr APPEALS BOARD MEMBERS SCOTT L. HARRIS Supervisor Gerard P. Goehringer, Chairman Charles Grigonis; Jr. �1 'Town Hall,53095 Main Ro Serge Doyen,Jr. P.O. Box 1179 Joseph H. Sawicki Southold,New York 1197 James Dinizio, Jr. BOARD OF APPEALS- Fax(516)765=1823 Telephone(516) 765-1809 TOWN.OF SOUTHOLD Telephone{516).765-1.80C ACTION OF THE BOARD OF APPEALS' Appl. No. 3931 Matter of JOSEPH SHIPMAN. Variance to the Zoning Ordinance, article X., Section 100. 102, for permission to . . institute a second business, Bulk, Area and Parking Requirements. Property contains less than.required business area. Property Location: 6619• Main Road, Laurel, County Tax Map No.• 1000, Section 125, 'Bloek 01, Lot'-19.7 . WHEREAS, a public hearing was held and concluded. on May 15, 1990 in the matter of the Application of JOSEPH SHIPMAN, under Appeal No. 3931; and WHEREAS, at said hearing all those who desired to be heard were heard and their testimony recorded; and WHEREAS, the Board Members have personally viewed and are familiar with the premises in question, its present zoning, and the surrounding areas; and WHEREAS, .the Board made the following findings of fact: 1. The premises in question is located along the northwest side of Main Road, Route 25, Hamlet of Laurel, and is identified on the Suffolk County Tax Map as District 1000,. , Section 125, Block 01, Lot 19.7. 2. This is an application for Variances from the Zoning .- Code Article X, Section 100-102, for permission to institute a second business, bulk, area and parking requirements. Property contains less than required business area. Page 2 Appl. No. 3931 Matter of JOSEPH SHIPMAN Decision rendered May 30, 1990 3. Article X, ' Section 106-102, No building or premises -shall be used and no building or part thereof shall be erected. . or altered in the B Distract unless the same conforms to the Bulk Schedule and Parking and Loading Schedules incorporated into this. chapter by reference, with the same force and effect as. if such regulation.were set for the herein in full. I., The subject premises is improved with-two framed buildings,. located to .the rear of the property-.is a 50, X 35 building: approximately 9 1/2 ft. from- the. southeast property line, 12 1/2+- ft. from .the northwest property line and the second building is located 53+- ft from the north side of t4ain Road, Route 25 and 25 1/2+- ft. from the west property line. 5.. In considering the application, the .Board finds and ' . determines: (a) that the circumstances of the application are uniquely related to the premises and its established nonconformities; (b) that there is no other method for appellants to pursue; and having a second business on this location will " require other variance relief; (a) that the variance will not in turn cause a substantial effect on the safety, health, welfare, comfort, convenience and/or order of the Town; (d) that in carefully considering the record and all the above factors, the interests of justice will be served. by granting the variance, as applied conditionally noted below. Accordingly, on motion by Mr. Goehringer., seconded by Mr. Dinizio, it was RESOLVED, to GRANT a Variance in the matter of the application of JOSEPH SHIPMAN as applied under Appeal No. 3931, SUBJECT TO THE FOLLOWING CONDITIONS: 1.' That the 35 X 50 ft. building in the rear of said parcel will be used as a second business that will not to exceed 35 X 50 ft. as it presently exists on the survey dated December .22, 1987 by R. Van Tuyl. Page 3 - Appl. -No. 3931 Matter of JOSEPH SHIPMAN Decision rendered May 30, 1990 2: That the applicant place screening forward 'of• the gear parking area, theriee starting at a point approximately 135 ft. south of the vest side rear corner. property monument and running east approximately 120+- with the exception that the applicant 'may put 'a. driveway for ingress/egress between the screening area not to exceed 10 ft.- in width. 3. That the evergreens be approximately 3 ft. in height and be continuously. maintained. Vote of the Board: Ayes.: Messrs. Goehringer, Doyen, Sawicki and Dinizio (Absent Charles Grigonis) . This resolution. was duly adopted'. df rr' {GERARD P. GO INGG19R, CHAP- RECEIVED AND FILED BY THE SOUTHOLD TOWN CLMK . DATE 9 gv HOUR a op _ � Town Clerk, Town of Southold. FORM NO. 3 NOTICE OF DISAPPROVAL DATE: January 27, 2006 AMENDED: May 30, 2006 TO: William Kelly a/c FHV, LLC PO Box 1680 Southold,NY 11971 Please take notice that your application dated January 17, 2006 For permit to construct an accessory storage building at Location of property: 6619 Route 25, Laurel,NY County Tax Map No. 1000 - Section 125 Block 1 Lot 19.7 Is returned herewith and disapproved on the following grounds: The proposed construction is not permitted pursuant to ZBA appeal#3931, dated May 15, 1990, for a second business on an undersized lot. The Notice of Disapproval included the following condition: "...a second business that will not exceed 35 X 50 ft..." Because the accessory building is slated to be used for part of that "second business," it is in violation of this condition. The proposed accessory storage building will require approval from the Southold Town Planning Board. f 1 This Notice of Disavvroval was amended on May 30 2006 to address the previous ZBA decision. a Authorize Signa e Note to Applicant: Any change or deviation to the above referenced application, may require further review by the Southold Town Building Department. CC: file, Planning, ZBA FORM NO. 3 NOTICE OF DISAPPROVAL DATE: January 27, 2006 TO: William Kelly a/c FHV, LLC PO Box 1680 Southold,NY 11971 Please take notice that your application dated January 17, 2006 For permit to construct an accessorysorage building at Location of property: 6619 Route 25, Laurel,NY County Tax Map No. 1000 - Section 125 Block 1 Lot 19.7 Is returned herewith and disapproved on the following grounds: The proposed accessorystorage torage building will require approval from the Southold Town Planning Board. G o .z i ature Note to Applicant: Any change or deviation to the above referenced application, may require further review by the Southold Town Building Department. CC: file, Planing. MAILING ADDRESS: PLANNING BOARD MEMBERS OF SOU P.O. Box 1179 JERILYN B.WOODHOUSE �O_.`� lyolo Southold, NY 11971 Chair V`' OFFICE LOCATION: KENNETH L.EDWARDS Town Hall Annex MARTIN H.SIDOR cn ,c 54375 State Route 25 GEORGE D.SOLOMON � �pQ (cor.Main Rd. &Youngs Ave.) JOSEPH L.TOWNSEND Oly Southold, NY "'UNT i Telephone: 631 765-1938 Fax: 631 765-3136 PLANNING BOARD OFFICE TOWN OF SOUTHOLD May 26,2006 William S.Kelly 22355 Cox Lane- Unit#4 Cutchogue,New York 11935 Re: Proposed amended site plan for North Fork Custom Audio&Video 6619 Main Road,Mattituck SCTM#1000-125-1-19.7 Zone: General Business Dear Mr.Kelly, After further review of your application and discussions with the Building Department and Town Attorneys office,it has been determined that your application will need further review from the Building Department as it appears that your site plan application and plan are not in compliance with the May 30, 1990 Zoning Board of Appeals decision (Appl.3931). This decision limits the rear business to 35 x 50 ft. and states that it maynot exceed this size. Please contact the Building Department for a revised Notice of Disapproval. Please do not hesitate to contact this office should you have any questions or need further assistance. Sincerely, Amy For Senior Planner Cc: File Ruth Oliva,Chairperson,Zoning Board of Appeals ilvli_chaeTj Verity`,Cliief-Biulding Ins orc Kieran Corcoran,Assistant T Atorn Town tey Planning Board -� a 1 66 � 2 Are there any questions from any 3 Board members? 4 Hearing no further questions , we make 5 a motion closing this hearing and reserving 6 decision until later. 7 MR. SAWICKI : Second. g THE CHAIRMAN: All in favor? 9 MR. GRIGONIS: Aye. 10 MR. DOYEN: Aye. 11 MR. SAWICKI : Aye. 12 MR. DINIZIO: Aye. +� 13 THE CHAIRMAN: Thank you very much 14 for coming . in. 15 MR. GREDICK: Thank you. 16 THE CHAIRMAN: The next appeal is in 17 behalf of Joseph Shipman. The legal notice 18 reads as follows : 19 Appeal Number 3931, Joseph Shipman. 20 Variance to the Zoning Ordinance, Article X, 21 Section 100-102 , for permission to institute 22 a second business, Bulk, Area and Parking 23 Requirements . Property contains less than 24 required business area. Property Location: 25 6619 Main Road, Laurel , County Tax Map 1 67 2 Number 1000, Section 125 , Block 01, Lot 3 19.7 . 4 We have a survey produced by Roderick 5 Van Tuyl , P.C. , dated December 22, 1987 . 6 The nature of this application is a one 7 story frame building in the rear of the 8 property, approximately 9 1/2 feet from the 9 east property line, approximately 12 1/2 10 feet from the Long Island Railroad, and the 11 reason for getting a denial is the second' 12 business in this particular building. 13 We have copies of the Suffolk County 14 Tax Map indicating this and surrounding 15 properties in the area. 16 Would you like to be heard, sir? 17 MR. SHIPMAN: Joseph Shipman. I 18 supplied the variance. I would be happy to 19 answer any questions the Board has at this 20 time. 21 THE CHAIRMAN: Presently you are 22 renting the building to another person other 23 than your own business? 24 MR. SHIPMAN: That is correct. 25 THE CHAIRMAN: What type of business? 68 2 MR. SHIPMAN: Storage for produce 3 business. 4 THE CHAIRMAN: We noticed that, I 5 think, there is about five trucks involved. 6 MR. SHIPMAN: Yes. Well , we use the 7 trucks to deliver produce. 8 THE CHAIRMAN: He does a pretty good 9 job parallel parking in one specific rear 10 corner of the property. 11 MR. SHIPMAN: He is a neat person 12 THE CHAIRMAN: We certainly can't put 13 restrictions on where trucks go. My only 14 concern is that originally when we dealt 15 with this applicant next-door, we requested 16 that the garage doors on that particular 17 building be placed other than facing the 18 front of the property. In this particular 19 case I believe you have one door, which is a 20 loading dock, which faces . . . is that one 21 door or two doors? 22 MR. SHIPMAN: Two doors . 23 THE CHAIRMAN: I notice that you have 24 a landscaping plant area in the center of 25 the property. 7S� 69 2 MR. SHIPMAN: The landscaping was put 3 there with the intention of trying to break 4 up the monotony of the building, so-to- 5 speak. 6 THE CHAIRMAN: Is there any way .you 7 can screen those trucks from the road other g than not . . . what would you suggest? g MR. SHIPMAN: I could run a screening 10 run of plant material., running from west to 11 east, and he could turn the trucks and park 12 them : . . instead of facing the road, they 13 would be sideways to the road . . . and the 14 plant material could probably screen them 15 very well , but it wouldn' t be instantly . is It would take a few years. But if I did 17 that, if I put the screening line where I 18 think . . . from west to east . . . there is 19 already a screening line already there that 20 the trucks couldn't see from the Main Road 21 between myself and the car wash. 22 There is a row of evergreens running 23 right down the line and, if I am correct, I 24 have driven it many times and you really L 25 couldn't see the truck from the Main Road, 1 70 2 coming from west to east. 3 THE CHAIRMAN: But you could see them 4 coming from east to west, because of the 5 height of the property. 6 MR. SHIPMAN: Because of the height 7 of the trucks as well . Something could be 8 done there. I don't see the problem with 9 that . 10 THE CHAIRMAN: .. Do you have any plans 11 of expanding this building, in any way? 12 MR. SHIPMAN: No. 13 THE CHAIRMAN: The approximate size 14 of the building is how big at this point? 15 MR. SHIPMAN: Thirty-five by 40 . . . 16 35 by 50. 17 THE CHAIRMAN: Is that building 18 heated? 19 MR. SHIPMAN: Partially. 20 THE CHAIRMAN: I don' t have any other 21 questions. Any question from the Board 22 members? 23 MR. DOYEN: No. Q 24 THE CHAIRMAN: We will see what else 25 develops. Thank you. SURVEY OF PROPERTY SI T UA TED A T LAUREL TOWN OF SOUTHOLD °p SUFFOLK COUNTY NEW YORK S.C. TAX No. 1000- 125-01 — 19 .7 oO SCALE 1 "=30' SEPTEMBER 4, 2007 s G�� ��-^,o��,�. `'• =:t::::°°aG � �,� AREA = ;0,65 �9 42 sq. ft. lip " 39' `-TO 43.5' �,,o.. V G e���� D • D�G'+ ��C,�/Gib ry�bj o�9 . "G `Z♦ 1D 1 B 05iF"6 •DRAIN 1p D D �2 0 Syr D •. . 'yc S5 ,tea � i b �yA 00 n ESS'��'• .• Dr Zo •CO�RS •. 0 SO _ t .•D •. D • OJ�G� ,y \vim !Q r °SEp�CCO�R� ° : UNAUTHORIZED ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION OF y^��y 'TA"� SECTION 7209 OF THE NEW YORK STATE Gyry^ �' 9�C+ a • ' ° �� EDUCATION LAW. d + D •• o COPIES OF THIS SURVEY MAP NOT BEARING `D D DRAIN ° f �'J 9 AO THE LAND SURVEYOR'S INKED SEAL OR 3y k �vDDf EMBOSSED SEAL SHALL NOT BE CONSIDERED DRAIND • a ,c�� S 6� �0 TO BE A VALID TRUE COPY. G • °' .• D CER RUN ONLY TO THE PERSONINDICATED PE SON FOR WHOM THE SURVEY F Q D • 'PRAIN-1, ' �G•� a IS -REPARED, AND ON HIS BEHALF TO THE mr °; o „ ° .D GO UO LENDINGTITLE 'INSSTITUTIONERNMENTAL AGENCY LISTED HEREON. AND / PgfA 00� D D TO THE ASSIGNEES OF THE LENDING INSTI- Pelt ti� . D ". t • TUTION. CERTIFICATIONS ARE NOT TRANSFERABLE. \ `rep e0� \0�� :,...'.,.;: • .• •,, y.. °' dN�'S. OSRpN"' •° ' THE EXISTENCE OF RIGHTS OF WAY IGN S•c GONG• .,L51 AND/OR EASEMENTS OF RECORD, IF �O ANY, NOT SHOWN ARE NOT GUARANTEED. O' PREPARED IN ACCORDANCE WITH THE MINIMUM STANDARDS FOR TITLE SURVEYS AS ESTABLISHED USE...'�•, BY THE L.I.A.L.S. AND APPROVED AND ADOPTED Nathan Taft Corwin III "> •� � FOR SUCH USE BY THE NEW YORK STATE LAND �::��• / •o��j.� �• •'• �� TITLE ASSOCIATION. C) T� �O Land Surveyor ��j� Coy �� -.V Title Surveys — Subdivisions — Site Plans — Construction Layout r PHONE (631)727-2090 Fax (631)727-1727 OFFICES LOCATED AT MAILING ADDRESS 322 Roanoke Avenue P.O. Box 1931 �Ale(p S� N.Y.S. Lic. No. 50467 Riverhead, New York 11901 Riverhead, New York 11901-0965 SURVEY OF PROPERTY SI T UA TED A T LAUREL TOWN OF SOUTHOLD SUFFOLK COUNTY, NEW YORK S.C. TAX No. 1000- 125-01 — 19 .7 ooJ SCALE 1 "=30' SEPTEMBER 4, 2007 AREA = 50,729.42 sq. ft. e C1 pe, 39' ►+c G J 43.5 C> �p op0 git u '0 GQy j 6°' �0.. ti cry �ti \\ �Ot�'I�GF' `:'G•tp��� •� a ",� J����G 1�0/�y9� l���P •a• p �g�G ��*'� p ' � n _ 65 r DRAIN SUFFC)t_!.CO:if•.';Y 0. POET a. GJPO n F�p i U(.I 25 2007 0 a ti c g �O ��2�F a •• -•.a - p '. :D •p • 4 ^ •"'o 1p 39� .D -p .• Zc �rLJJ�V� J yc •COVERS � a r p °�, i qR °SEPTIC D UNAUTHORIZED ALTERATION OR ADDITION O a.w ��� CAVEit s , • TO THIS SURVEY IS A VIOLATION OF SECTION 7209 OF THE NEW YORK STATE p EDUCATION LAW. � r + " • p �f1 COPIES OF THIS SURVEY MAP NOT BEARING a DRAIN p j •� ,�O THE LAND SURVEYOR'S INKED SEAL OR yy� a .• n v�p/• EMBOSSED SEAL SHALL NOT BE CONSIDERED 1p ' DRAINS ' • n • r � S 6 � TO BE A VALID TRUE COPY. FOCOo s p�G�G p• ,� No QO CERTIFICATIONS INDICATED HEREON SHALL RUN �a ONLY TO THE PERSON FOR WHOM THE SURVEY /�'O�F �cti p QP��\ p .• DRAIN\ d ��ON O IS DREPARED, AND ON HIS BEHALF TO THE GO a TITLE COMPANY, GOVERNMENTAL AGENCY AND ryyh, \ p • o • •,' V LENDING INSTITUTION LISTED HEREON, AND ro\ a ` TO THE ASSIGNEES OF THE LENDING INSTI— PRE TUT10N. CERTIFICATIONS ARE NOT TRANSFERABLE. \ bo Sao RON:: THE EXISTENCE OF RIGHTS OF WAY IGN S G .G Ps ..:. .. p � coN • �' �2y� AND/OR EASEMENTS OF RECORD, IF ITO R ANY, NOT SHOWN ARE NOT GUARANTEED. 5, \ �i ,.Q' PREPARED IN ACCORDANCE WITH THE MINIMUM Jo�(I p ����••J// STANDARDS FOR TITLE SURVEYS AS ESTABLISHED...'i BY THE LI.USE AND APPROVED AND ADOPTED Nathan Taft Corwin III > •• � FOR SUCH USE BY THE NEW YORK STATE LAND TITLE ASSOCIATION. �OF Nf W Land Surveyor co ¢�jAFT Title Surveys — Subdivisions — Site Plans — Construction Layout T PHONE (631)727-2090 Fax (631)727-1727 OFFICES LOCATED AT MAILING ADDRESS 322 Roanoke Avenue P.O. Box 1931 CA (pSv N.Y.S. Lic. No. 50467 Riverhead, New York 11901 Riverhead, New York 11901-0965 1 J J J J J m NORTH FORK AUDIO £t VIDEO 6619 MAIN ROAD ' MATTITUCK, TOWN OF SOUTHOLD . 0 SUFFOLK COUNTY, NEW YORK _ - P O TAX MAP NO. 1000-125-1-19.7 0 H i as well- PROPERTY O O O OWNER: I O / m w I- LL F- Lu I FHV, LLC SEEDED AREA 2a'O CAST IRON.TRAFFIC-BEARING PO BOX 1295 O O O Z z G - CUTCHOGUE, NY 11935 �� OPENGRATFRUNO RUNOFF) �� SOLID(ROOF RUNOFF)COVER � � � Z a `��� Q\��\C Gp�a CHIMNEY TOP SLAB(TYP)BEARING(--MASONRY TRAFFIC O 0 C)Z O_ I SITE DATA �5 I Qa ti > p _ ZONING CLASSIFICATION GENERAL BUSINESS - B ^ cb� / G n �� =:NISHEDGRADE � > y CIO '. %� O Z CURRENT USE OFFICE, RETAIL, CONTRACTOR w �, w o a �," //moo;; O w O F- Q w O ` ` 5° p 2 ' J J� �/V v�JYyO�`' Stir v✓�'\ i.j�ljJ✓ J✓C�% v/J/ F-' Z ED USE OFFICE RETAIL, WAREHOUSE, CONTRACTOR � �s c'� �� �-3 � ""� � � Yl / � PROPOSED O h o � � � yl ,� ✓,� r, �� r y,, \1��. � Ix nw/ o T i'✓i✓i�✓i✓i r i✓i/i✓//�i y� : �%'✓i:�/.� . '�?��✓,��/i '�✓i�� ;✓�/i/✓i✓i✓/��li�✓✓i\✓/li:/i�iyiyl LL TOTAL AREA OF' SITE 1.1645 ACRES / 50,725.358 SQ.FT. . � �s ' OJy 200 S a aw Q t AREA OF BUILDINGS 6,090 SQ.FT. (12%) Jr0 / �,� CO Q ® ® ® ® ® Q wa Q Q AREA OF PAVEMENT 25,482 SQ.FT. (50%) Q' / �G' �,'�'� �� 5a (PI 8•CORRUGATEDPOLYETHYLENE :. PIPING FROM ROOF LEADERS(TYP.) a WALK 576 S .FT. 1% �` : I m AREA OF CONCRETE Q ( ) ;`�O cj �'� oc• �o -OR- ® ® ® ® ® ® ® ® ® 0 N 12 d �Qc :.:; W NATURAL/LANDSCAPED 18,577 SQ.FT. (37%) �nJ , 12 Q O� - ' On- 0 15•CORRUGATED POLYETHYLENE PIPING > • ALLOWED - 15 218 S .FT. OR 30% 5 -- O� �e� ® ® ® ® ® ® ® ® ® COVERAGE. (BUILDING) Q ( ) / 0.3� MID-ULTI LEDRIV CONNECTION I A_ A \ i BETWEEN MULTIPLE DRIVE POOLS(TYP.) ® ® ® O PROPOSED -6 090 SQ.FT- OR 12% t 1" :: u _ _�� : : % •••.- 0 ® ® ® ® ® ® 0 0 0 0 0 d" . ai O , cV Qi COVERAGE: LANDSCAPING - ( ) K\ o �. O C7 O N N Q uj a . . ..... ........................ .... LANDSCAPED AREA TO BE PROVIDED - 17 754 SQ.FT. OR (35%) • � MINIMUM L . : I:: .3g:.:.:•: :: : :::. N Z , o rn c�i O :.. - 0 0 0 O - - ........... . PROPOSED 18,577 SQ.FT. OR (37%) OQ " ' : sr :STE) )?Afl(IfiIG AF2A:2';(.622 SZ�. :}::::::::: W -�•o•MIN. ^RYwELL ' �� C :• ::::::::::: : ::::::':::: :: ::. Q PARKING CALCULATIONS o -- -- - --- •�': :v �' _ - / _ -_- ` .. OFFICE Et BA TH r.. C R O GROUNDWATER 3 G OU PROVIDE 1 SPACE J/ 100 SQ.FT. / - - " Q j _ C7�.:'.' O AILSPACE RETAIL :� ��•'• . 6': RIAL T'O BE CLEAN I MATE 6' BACKF u .. ..... ... ........................... .... .. .... ... ............... .. ........................... PROVIDE 1 SPACE Jl 200 SQ. FT. '7 .`�` :':'::::i':•:::::•:•:•:':•:•:•:::•f::: :•::::::':::::: :��`::: '::. :::':. o SAND AND GRAVEL(TYP.) �� ::� ,.. - ... LLJ G ;. v NTRAC T0 R BUSI NESS Et YARD O .�.... ....... .... DETAILS PROVIDE 1SPACE PER EMPLOYEE 2 SY STEM TEM HOOKUP - D E TA IL SWAREHOUSEAFEA �a DRAINAG _�� . ' :PROVIDE 1 SPACEJ 1,000 SQ-FT. ::: 3 r T SC ALE NOT TO t r� O 85 .FT. , O 17 N U LDIN G #1 AUDI O/VI S B I Q ( :.t: o. fr BATH 443 .FT. o Q) 0 OFFICE Q -,- L .................... ........... ........:::: . .................... ...................... . PARKING REQUIRED 5 SPACES d�... r _ - o •� �:. `: ::.. } .FT. M 546 S � co IL SHO WROOM 30 -RETAIL 5 - Q 5 0 DW Z P E - sr • 7 ® C 3 SPACES I D S IRE PA RKING, REQUIRED � �� LLI Q vi :•'CI 0 7 � WAREHOUSE AREA 796 SQ.FT. - :jw. ` :. :;: :•:: q- Q C� CU ......... ........ s ..'::. ' ?i m .::.::. PARKING REQUIRED 1 SPACE F 2 O q � ' - 0 9 SPACES TOTAL PARKING REQUIRED F •- co - �/••.. o ti IN L DE 1 HANDICAPPED SPACE O :'::�.':: ::::': ::: : .:.:... :: : . :.. :............... CI) o a TOTAL PARKING PROVIDED 12 SPACES ( C U S ) -9 ::T%G- -p ... ... r J :�:::::::� 9�::: N O^ - EL 21.5 _ 0.0 O E �� T MIXED SAND C DO CU BUILDING #2 (CON T 5RACTOR) 1,785 SQ.FT. mod::: :::': ::::::::::• °o 11 ?i�0. O^ AND LOAM O _ OFFICE Et BATI 455 SQ.FT. y9 :: �. O� 5�4 ��. :;�.::::::::: : -': :. 'Fp - - 2.0' Q U PARKING REQUIRED 5 SPACES O l S CrihiTRACTOR BUSINESS 6 EMPLOYEES "z� QO _ PARKING REQUIRED 8 SPACES �Fti n�,o 0�''lF��o54 �G� G c3`� off':` BROWN FINE TO .. .......................:::.:�.� y N COARSE SAND WAREHOUSE AREA 1,330 SQ.FT. � ' Q`���\�. ���, \���� s .••:nlii`-:r�2ti�t �ri�iY.3•:(22st-St� .) � WJ20%GRAVEL PARKING REQUIRED 1.3 SPACES TOTAL PARKING REQUIRED 14.3 SPACES '�° ? G� :.z. ' . g" .�� TOTAL PARKING PROVIDED 15 SPACES (INCLUDES 1 HANDICAPPED SPACE) .��- O ti �,_-- _SW , 5 \ w 10.01 D _ � oe�� PALE BROWN ` BUILDING #3 (WAREHOUSE) 2,520 SQ.FT. o� �' 0 e_ �I =0 FINE TO WAREHOUSE AREA 2 520 SQ.FT. �`�� O ��a Q`� EDIUM SAND I" 2.5 SPACES o o :TiG:::. s U G.W.cw EL. to.7 sP 10.8' PARKING REQUIRED o� SEEDED AREA � P i REQUIRED 2.5 SPACES TOTAL PARKING �` D 0 Q m, 18-REDOAK '.i;•( .� WATER IN TOTAL PARKING PROVIDED 2 SPACES `L, 11 \` 20-'SILVER MAPLE � PALE BROWNc- ,' FINE TO �� `' .� a 4 , �j Z MEDIUM SAND , / O e timbercu�' - \ � ' ' e � 5DRAINAGE CALCULATIONS 17.0' -Ile _ a '°� BUILDINGS #1 £ 2 a - TEST HOLE ROOF AREA EACH `� "m�' 3 ROOF AREA = 1 ,785 SQ.FT. X 1 .0 = 1 ,785 X 2/12 = 298 CU.FT. `° NO SCALE m ; ti ASPHALT PARKING AREA 4,(9027 SQ.FT.) TEST HOLE PERFORMED BY McDONALD GEOSCIENCE CAPACITY REQUIRED = 298 CU.FT. EACH �p PROVIDE (DW 1 &t DW2) L o o .'(�Q' 4 Cry ' .VmmeRsunarn,Pc)RSUAxr'to so i`rbt CCOc�r �' >- HING POOL 408 CU.FT. EACH °�� '� 0 .EAC 9 �; ,r..n.?•��'�).'��':�'Nn1.Fl?CiPSTHATTHE .� O 2 - 10 IDIA. X 6 DEEP L ( ) 6 0� 4', 'E':FORTH IN i, •U' AFFR DATED z TOTAL CAPACITY PROVIDED 408 CU.FT. EACHELF ��r� �� FLsitiSEPP.TN. \ 0 16 joy` 'P I C� `' y ,� 2 l���c`'?�� �C`� O z BUILDING #3 �- �,� o^ ��2 ,�\�C�`G, '� ,o d ROOF AREA cs� s �., , 5 ^o� 0 (o t,:rr�Pc�k.v a°sttih AT UIt> t�Lt� DATE 2 X 2/12 = 420 CU.FT. ��o p � �'�� �'� 'L3 oo - - R ,, Dv ROOF AREA 2,520 SC�.FT. X 1.0 2,5 0 CAPACITY REQUIRED = 420 CU.FT. - -- - o0 � rawrr nt�Sau�lolvn'�t.nxzzcrta B4PRA U Q O � Z PROVIDE (DW3) <-L�c� �- _/� 9 _ ,, , Ll n Q Qt � �-��.��C 'ty mnlr�^�!rter�,hmlr-refs C/J Q `' 1 ` �9 ��Nv� ti ALf .O",IZLU5I�:,NATUkir 1TTLE pATli 1 1 - 10 DIA. X 8 DEEP LEACHING POOL ( 544 CU.FT.) LL ..._I TOTAL CAPACITY PROVIDED = 544 CU.FT. �__ 1 P j �� P O, �� DW7 Z ` y6o��P -_ -.i- N01'E•The approved site developtmtsrt plea s2:a11 be valid for z O (9' 1 O a period of three(3)years from the,dllp,Of apinoy;!l_aS- •..;" " � ^ Q STONE PARKING AREA 1 ' TAG - z W W code section 100-255. :--�•r-°�`" PAVEMENT AREA = 8,1:34 SQ.FT. X .60 = 4,880 X 2/12 = 813.4 CU.FT. - D®8 el 22.0 -. ��, ,_ -- : O -`, M.� 1 Z p - CAPACITY REQUIRED - 813.4 CU.FT. 0 Q• _ 1 ,fit �� 'I, A� Q C� PROVIDE (DW4) p�yt O ® 2• de�e° �` ' ti LL ~ Z 1 - 10' DIA. X 12' DEEP LEACHING POOL ( 816 CU.FT.) SEEDED AREA QQ T/G DW9 TAL CAPACITY PROVIDED = 816 CU.FT. `�' P ^r TO �cl� EXISTING SIGN el 21.7 �O e m ;4 STONE PARKIiNG AREA 2 �` TEST F 9j ci? 1 \14 HOLE ��\ di 21 F_ Q PAVEMENT AREA = 6,222 SQ.FT. X .60 = 3,733.2 X 2/12 = 622.2 CU.FT. CAPACITY REQUIRED = 622.2 CU.FT. 2��L PROVIDE DW5) �c _ --------- -- � �°G� `t. .:�.� •Y.. � ;,:...--- y` Q 1 - 10 DIA. X 10 DEEP LEACHING POOL ( 680 CU.FT.) A - ~- TOTAL CAPACI TY PROVIDED = 680 CU.FT. EE� LIGHTING SPEC IF'ICATIONS- STONE DRIVEWAY AREA 3 e- �Z---- ac `,,� �N o AREA = 2 2�81 SQ.FT. X .60 = 1 368.6 X 2/12 = 288.1 CU.FT. DRAINAGE & PARKING PLAN n �� PAVEMENT A , Q ask °° '" A - RUUD E4405-D 50 WATT WALLMOUNT METAL HALIDE DOWNLIGHT c 10 ABOVE GRAD DRAWN BY. LR CAPACITY REQUIRED = 288.1 CU.FT. SCALE 1" = 20' ��Reie s\ae� ryo' �pV`! ��Q�Ci B - RUUD DU405SYM-D 50 WATT SEALED METAL HALIDE WELL LIGHT PROVIDE (DW6) �/ G ' DATE: 02.24.06 1 - 10 DIA. X 5 DEEP LEACHING POOL (340 CU.FT.) C - COOPER 91;: WESTWOOD 50 WATT" WALLMOUNT HALOGEN DOWNLIGHT c 8' ABOVE GRADE SALE: AS NOTED TOTAL CAPACITY PROVIDED = 340 CU.FT. �1 SHEET ASPHALT DRIVE Et PARKING AREA 4 PAVEMENT AREA = 9,027 SQ.FT. X 1 = 9,027 X 2/12 = 1 ,505 CU.FT. CAPACITY REQUIRED =: 1,505 CU.FT. ALL SITE DATA FROM SURVEY BY JOHN C. EHLERS, LAND SURVEYOR, D o PROVIDE (DW7, DW8 Et DW9) RIVERHEAD, NY 06.13.04 - REVISED 02.07.06 3 - 10' DIA. X 8' DEEP LEACHING POOLS (1,632 CU.FT.) TOTAL CAPACITY PROVIDED = 1,632 CU.FT. OF 2 SHEETS .\Com i 1 1 y,r,`39d i' RECfAWOULAR'MD WALL MOUNT PROJEC'1IUN CUTOFF IY IY IY _j Of J J J J J m IIsolool=de*t8 sfm kr U 1nM avift at grade. F ANGLE MEAN CP AWE- MEAN CP 0.0 933 57-5 2522 Q - _ 5.0 an 600 e9_5 23M ...I F1 (� well--- to.0 rM 659 2842 O 1 �O� SOQ1� 20.0 1182 67:0 zs7 / 25.0 12e7 1407 ITEM 10508.0102 I4•) ITEM 10608,0103 (6") ITEM 10608.010E (4") O 50.0 1301 72-5� G�i / SEEDED AREA m• a51 1230 n-5 343 _ O = w n? �, loo0 40.0 10fi7 80_0 183 (n F- W 45.0 2141 MS 125 O O O Z IL Z_ CD I WIDTH SHOWN ON PLANS I 525 4854 a s 76 MAX. SLOPE 1:!2 DRIVEWAY WIDTH SEE NOTE 2 � , �. -_ G �a lsoo-` ss.a 2659 so_0 63 3' C� I tea. O % G°�a L- Z a O O W U Z �� ny MaldmumCanalepower: 2654 HIGHWAY BOUNDARY� O Z � O y� 2000 Pbm of Mm"vort CP. Ir - v p� ` 2 I Vertical Anp10 of MaxlmOm Candlepower•- 65' 10 0" DIM I "C' SEE TABLE NO Z F- Z � Q (n ` G �y O� N G ,aa h1 1` <i Lunen Fmfv: t3400 _ < 3 � Z > Q 2� r O O 5'-0" I E C F- W F- IY "may J '� LMWWI aeb"M file SCOR( MARKS Cx� ►''S. �J` �`� --� 2 r'se°n"N°'L>e>�° EfFlC1ENCY=60.1% Z �O� z�_ CT Ierwer HsIrMIM1 eerre M ra. Ilt'e E W 0 rrailseeoa atoN ftIlrn. / L ` a O a - - I / '�\ � � '•' y a.-: �, + --'t PFIOTOMETRIC DATA W �� HID-EDUIMP i.'3 ' >''; t :. _;- ....;-,_ SEE NOTE 1.0 CURS co SEALED WELL LIGHT . ; ;.� - ,- .:.:.-,. Westwood-" ^ Q •�• ul 3 1^�3c -�,,,lit+:,�. r{ -�- - - - -j,M'i �- -I"1"•r Cone of Light �,, ............ • J .: •,: v . ,. u ` I.. a:' i..: I I. ..,.-..i, Larf 50PAR20/NSP Q QO O� O O 1 i. '.r. • 1.� ,. �Ch= D Dittat�esty ItIFeiY Ntd� 13Mtn 3' DRIVEWAY WIDTH +6' 3' 0- ............... 5 s MumimtedPhtN Foatandes, �• T •,J• I.1 fOFaeneter 3/ EXPANSION JOIN a D� / �j VOA Gp0 1n..i' i s.j_.i{ ,. 250' 8 10'0• 1 ,( .?tom. : _a _ 1- i- : `WIJ t ,,.. . L.; D 2 a' csJ 23 O O O O o g0• t` a.. o 0 0 0 o W 1 e - '+' -I+ + tzo• a5 so• 3� 4 Q) O N O F- p I :'::::::'::'::'::':::::::::'::::':: 3'�:':...........:'. 1o'o• so a'o- DRIVEWAY CONSTRUCTION PLAN o c� O " c l Q �Aac:: •.•.'.'.•.'.'.'.'.•.'.'..'. •.•.:'.:'._...::.':.':::.'::.'::::. Dioleves In thlss O/Mameng Me%M 8,°. 3,°• . :::::::::::::::::::::::: ....:::::::::::::::. O 0) co c) ST6N. •'PARKN6-AI3,5k:' .':$22�:$1�.F3:)::::: :::. SGALEe N.T.S. � - O O O ?� S nIr IPs McI1dr t�Igbcttw JkleW -- - - _ o 1200i1 �u1 a w tr ■ M rkw - ro Iseeeq . _ I ... 3 ::. I•10T'ESr ' - 30 N t, THtS SLOPE NAY @ REDUCED TO f!A /F7,A5 NEGE55r4RY FOR SMOTHER TfZAN51TI0Nr TO ADJAGPNT F1aOPERTIES. P` O ' �.......' ::::::::: t iN C3A.K�MG:'ARE :1............ ... .... ...I..-.............. ............ .... .. w�seWooa s�um� z. Tl+ese 5URFAGES`aHA(L BE GIVEN A SLIP RE515TANt TCXTt1RE.A GOl1R5E BROOM PIN15N f'ER NDIQILAR TO THE 51DEM1ACK 5LOF'E I5 AC1xl'TABLE. �. �O ` Cone of Light am 20 l OPAR M G 1� 1 s000 .�• 1 distance to Inhid Hadir V J 1 9 Beam :l- CBCP=1 400 Illu� imirTated Plane-- Footemdlea Diameter 2 ' I W .................- 25•0• 2 0- 9 za R N IT T FOR .Y S.D. T. R Q `� - sD- : . ITEM LIS O. E 20 D 3 1 O •iP• .' 160- 9 15'0 s � o- ' ? r t� x' o so- ........ . ............ 1 � CSC. ........ -;`�•�• .... ...•:: r ' ITEM N DESCRIPTION .O - �o'o s J3'°- TE D. O t Id' Sciences ht••�• c, Sciences 19 � U eases Inc. 8'0' ��- U F R I 10 N RT I WAK RiNO GD O GO E E 5 D E E°led 60 .O 2 G E L UN Cert Tes} N O 8 Roped o.LSI 132?'I eftffl d T R N C e eat e ° L I ti a oR 51132'25 :.y. ��/} ndt ist 9 Ca ovrer d ribntisn 01M cnnle e 7 _flfH arM! r C tnro dialrlbntMlt o170yV H eP enrae to CONCRETE T •F I G E RI WAY G A55�•�:•�•' 10 08.0 03 GO E D VE 5 L O 0 ............... ...............:':: ::::.:::::::::::::::::::: .... �.Y'j•.'.•.'.•:••�•�:•��.:��•�••••••••�.:': � Seated Well Light to amp Sealed tL�nll Light With clear lamp. _ :f ;{� r :: ::': :::;. (standard). Q) rn )- o` ''^^ vJ T •' •. -' f 1. 1 GG .......... DW5• i� .� i �.. co z ti Z - t Q .............. w' c to ;: �' O FxISTTt4r4 1::.:: 2j CC �. r7R1 Y C VE:YtA : 3? : .G q- -•r'- � m (� fr. / O . ' G FULL HEI6IMT CURB �•� 0 �A�;!9:88 .. .+ : : ' O '9 Q� y ° TOP Itern 402.Or18301M 4 - ,� --- -- 2 - 5 3 1 7� (� �� 7' ? •+ - hem 402DgB301IM , T'- / y / :. '.;`'::':::: / 4 2"---- ASPHA°L E DRwEWAY ry Item 402d4Jj9011M , ItJ �,•,: U ` O O ! _ ... aL- Item 4 Q �. :, Q 5<(� 0. �(� ••i•• ' • i+ ex►stxtg pav't 31NDF1? 402.198401M 1 ` y ` Vv i, d9 2 ; 0� 0 !G :>• G is l;` OR1 VEt^!AY GUR'3 SECTION r ASE i 14 w 0 S Item 402318GOIM i O� Q� �G S filE Df2F1�1=VIl ilC:3::(228t SQ ) IV `► Item 402318�1OiIM Q 1 IL IL '.... SUBBASE ' Q n' t of v mn+I a i I ' r Item 11304.1011 �P . :':::::: :::::. _ ry .; `-•- rTFM 10405)"03'FULL DEPTH) N : _ ��5 .DRlV r iY' SECTION A A I D Q�' O '' �� xALE: W.tr,. DETAIL rL 0 MEETING EXIST,A5FI4ALT PAV'T O (NO RESURFACING) i \ \ -....... � 1 ITEM 10403.0"SAW C.VtIIH&ASPHALT/CONCRETE .., of m •:TLC:•:':-. �p� SEEDED AREA :.:. NOTIsr D ........ :..'.' . CONCRETE CURB RED OAK ;;; 1.DETAILS SIHOW METHOD OF SLOpINb AFtD GONSTRUGTING'DRIVEWAY APRONS. TYPE A M ` 1� WHERE CO •IGRETE 51DEWALK 15 NOT-REQUIRFD R 'DIRT' DRIVtWAYS NOT ITEM 106041.2501 _ I 20'SILVERM,VtE U ` SPECIFIED THE DRIVEWAY 15 TO 13E CON5TRUCTED OF 9' OF ITEM b06.O201 AfJp N.T.S. nc� _ T Z ,yp GON5TRUGTED TO THE LAYOITr AND SLOPES NOTE.THE END Or CURI5 NOT ADVrTINS ExtSTe+e CIMD 'L SHALL eE RAMPED DOPIN TO ZERO 1Ef6r1T REVEAL IN m 1�9 10 ! THE LAST 10 FEET AT LOCATIONS FACING TRAFFIC. I �p -' ' 9 gmbercurb-" �� -o `� 9 14 ' b ITEM 1060(.5.2801 ASPHALT GONGI'ETE 51DE'YVALKS AND BICYCLE PATHS 1 >' 3 _q:u 1 ' �7 ASPHALT PARKING AREA 4 (9b27 SQ.FT.) a 0 SHOULDER WORK AREA 1 %" S.C. TYPE 1A °v 0 ,�(P• w ARING COARSE }: ig o Alto { �� �0 O� �� `°� O © $� �� '�� 2 %2' S.C. TYPE 1A z i q -l4X T �� i �, GRADE BASE COARSE �O O�/� �p� Cj s� o' � \�/\�/\� \�/\�/ _ = 95% DRY DENSITY Gas '� �, ���\��\�� ,/ 2s G) �+ ,� Ago K _ " _ o O ��(� ���y 5 O,� O O � RO D WOR _ - -17 - J O1,- -------------- - io C) F- 1 (� / ALL LANE5 K)5T ER! N e r , OPE TO TRAFFIC BEFORE 9 AM AND - � v ��• O / AFTER 5 PM NO LA 1N65 ARE PERMITTED ON ND5 cr) _ U M �3' OR HOLIDAYS. NIGHTI GL05 WEl'KE O W I ' ' O _ ME LANE GL051N65 WILL NOT BE =.:.: O W W � 00 ` �N�� PERMIT INSPECTOR.TOU PRIOR TRAFFAPPROVAL PROM THE STATE j '; •:' .'3�_ r G CONTROL SIGNS UTILIZED AS PER REGULATIONS. �� 0 6 O ' ;: z o V DW8 el 22.0 > Z _�`�_. ® EXAMPLE OF TRAFFIC CONTROL �� 1 /ice ��\//i\ z \ O -.�'' 2� AT SHOULDER WORK AREA Il � W o Il 611 GRANULAR ACCORDING TO FIGURE 302.a OF THE N.YS.D,O.T. LL (0 F- ® ��'• etie G SUB-BASE SEfDEDAREA 3 �.p DW9 ,1 r E Goad �'� MANUAL OF TRAFFIC CONTROL DEVICES r, O T/G n/ CJ ei 21.7 P• �pF 50ALE7 N.T.S. LL EXISTING SIGN SUB GRADE (� C ',Ban TEs NOTE: CONCRETE TO BE 4000 PSI @ 28 DAYS HOLE ��' :p u NOTE51 I06 - I 'A< 2$ FQP I. SEE SECTIONS 234.10, 238.1, 235.4; 23b.1, 254,2, ON VIRGIN, UNDISTURBED SOIL 301.2. AND SUBGHA'TER CG. 2. FOR TRANSITION LENGTH, L SEE SECTION 301,12 t CURB DETAIL Q NO � E LEGEND �; SHOULDER BELGIAN BLOCK / 1'LA6cyER NOT 0 SCALE-PROVED BY PLANNING [30AF'.•D v I cool: LD DRAWN BY: LR s� t UTHO TOWN 01= S® G ® WORK AREA DATE: 02.24.06 DATE SCALE: AS NOTED / GONE WORK SHEET DRAINAGE & PARKING PLAN SCALE 1" = 20' ALL SITE DATA FROM SURVEY BY JOHN C. EHLERS, LAND SURVEYOR, [00p= RIVERHEAD, NY 06.13.04 - REVISED 02.07.06 OF 2 SHEETS \C0m - 1 OFFICE: CUTCHOGUE, NY i F'�� MORTON BUILDINGS GENERAL SPECIFICATIONS _\ � 128-0765 LAMINATED COLUMNS - NO. 1 OR BETTER SOUTHERN YELLOW PINE NAIL LAMINATED 3 MEMBER S4S COLUMNS USED IN MORTON BUILDINGS ARE PRESSURE TREATED BELOW GRADE TO A RETENTION OF .8 \ o POUNDS PER CUBIC FOOT WITH CHROMATED COPPER ARSENATE TYPE III, OXIDE IN CONFORMANCE � WITH USEPA GUIDELINES AND AWPA STANDARD C28. THE TREATED PORTION OF THE COLUMN / EMBEDDED IN GROUND SHALL BE LAMINATED WITH STAINLESS STEEL NAILS. a- O ��j EXISTING FOOTINGS AND ANCHORAGE- COLUMN HOLES ARE DUG A MINIMUM DEPTH OF 4'-8" BELOW GRADE 35'x51' \ �-- w NS WITH GALVANIZED SUPPORT STILTS ARE PLACED IN BUILDING (SEE PLANS FOR DIAMETER AND DEPTH). COLUMNS W/LOADING (- °� THE HOLE. CONCRETE (MINIMUM COMPRESSIVE STRENGTH 2500 PSI) IS POURED IN PLACE TO THE 1.9k, DOCK � Z Lu SPECIFIED THICKNESS (SEE PLANS FOR REQUIRED THICKNESS ABOVE AND BELOW THE COLUMN). THE 01'A Op Z COLUMN IS THEN BACKFILLED WITH SOIL AND COMPACTED AT 8" INTERVALS OR BACKFILLED WITH / a. CONCRETE (SEE PLANS). TREATED LUMBER - PRESSURE PRESERVATIVE TREATED LUMBER OTHER THAN LAMINATED COLUMNS ARE U NO. 1 OR BETTER SOUTHERN YELLOW PINE AND CENTER MATCHED, PRESSURE TREATED TO A NET .� [Z RETENTION OF .6 POUNDS PER CUBIC FOOT WITH A CODE AND INDUSTRY APPROVED PRESERVATIVE \ �.) LjLj TREATMENT IN ACCORDANCE WITH AWPA STANDARD C2. Q Lj j N26038'30"W \' FRAMING LUMBER -SIDING NAILERS ARE 2x4 S4S OR 2x6 SPF NO. 2 OR BETTER SPACED APPROXIMATELY 12.00' r ^ 36" O.C. WITH ALL JOINTS STAGGERED AT ATTACHMENT TO COLUMNS. ROOF PURLINS ARE 2x4 S4S NO. W s 2 OR BETTER ON EDGE SPACED APPROXIMATELY 24"O.C. ALL OTHER FRAMING LUMBER IS NO. 2 OR BETTER. ti �G GL-10 ROOF TRUSSES - FACTORY ASSEMBLED WITH 18 OR 20 GAUGE GALVANIZED STEEL TRUSS PLATES AS REQUIRED AND KILN DRIED LUMBER AS SPECIFIED, IN-PLANT QUALITY CONTROL INSPECTION IS F0P0 6� = Q �" ' CONDUCTED UNDER THE AUSPICES OF THE TPI INSPECTION BUREAU. TRUSSES ARE DESIGNED IN MORTON BUILDING ACCORDANCE WITH CURRENT STANDARDS AND SPECIFICATIONS FOR THE STATED LOADING. '�2 c U U10 DISTANT TO SIDING PANELS (KYNAR 500 / HYLAR 5000) -0.019" MIN., G90 GALVANIZED OR AZ55 GALVALUME, WITH �� PROPERTY LINE J Z l 1 1 AN ADDITIONAL BAKED-ON KYNAR 500 / HYLAR 5000 FINISH WITH A NOMINAL 1 MIL. PAINT THICKNESS �P\� � ') �'- O Cie ON EXTERIOR. \ G BUILDING LOCATION PLAN ] = o � U ROOFING PANELS (FLUOROFLEX 2000 T"') - 0.019" MIN. AZ55 GALVALUME WITH AN ADDITIONAL g0� 7.5 30' Lil BAKED-ON THICKNESS POLYURETHANE PRIMER AND KYNAR 500/ HYLAR 5000 TOPCOAT WITH A TOTAL SCALE: 3.75' 15' 60' x MINIMUM PAINT THICKNESS OF 2 MILS ON EXTERIOR. 7 m • L O TRIM - DIE-FORMED TRIM OF 0.019" MIN., G90 GALVANIZED OR AZ55 GALVALUME STEEL ON GABLES, BUILDING DESIGN CRITERIA TYPICAL LUMBER SPECIFICATIONS - 2001 NDS °- • RIDGES, CORNERS, BASE WINDOWS, AND DOORS WITH SAME FINISH AS ROOFING OR SIDING PANELS. SIZE DESCRIPTION BENDING VALUE Fb BUILDING CODE 2002 BUILDING CODE OF NEW YORK STATE 2x4 NO. 1 &2 SPF 1313 PSI l 1 Lj USE GROUP S-1 2x4 2100f MS SPF 2100 PSI N GUTTERS - 5" K-STYLE, .030 HIGH TENSILE ALUMINUM GUTTER, KYNAR 500 / HYLAR 5000 FINISH TO MATCH CONSTRUCTION TYPE VB 2x6 NO. 1 & 2 SPF 1 138 PSI a- TRIM, ON BOTH SIDES OF THE BUILDING. FLOOR AREA 2520 SQ FT 2x6 NO. 1 SYP 1650 PSI V; FLOOR LOAD 125 PSF 2x8 NO. 1 SYP 1500 PSI l 1 1 0 ADDITIONAL NOTES MEAN ROOF HEIGHT 21 FT 2x10 NO. 1 SYP 1300 PSI 1.) ALL PLOT PLANS AND RELATED DETAILS SHALL BE PROVIDED BY OWNER UNLESS INCORPORATED BUILDING CATEGORY 1 V 2x12 NO. 1 SYP 1250 PSI _J AS PART OF THESE DRAWINGS. ROOF SNOW LOAD* 26 PSF ALL 1950f MSR SYP 1950 PSI -� 2.) ALL INTERIOR PARTITIONS AND ROOM FINISHES IF NOT INCLUDED WITH THESE DRAWINGS SHALL BE GROUND SNOW LOAD 45 PSF 1 1/2"x16" LAMINATED VENEER LUMBER 2800 PSI PROVIDED BY OWNER, STANDARD FINISHES SHALL HAVE LESS THAN 200 FLAME SPREAD RATING AS WIND SPEED (V3S) 120 MPH 3 1/2"x15" GLU-LAM 1650 PSI 5 1/4"x16 1/2" GLU-LAM 2400 PSI REQUIRED BY ASTM E84 FOR ORDINARY CONDITIONS AND 25 OR LESS FOR EXITS, PASSAGEWAYS, WIND IMPORTANCE FACTOR 0.77 5 1/4"x1 1/2" GLU-LAM 2400 PSI AND CORRIDORS. EXPOSURE CATEGORY B NOTE: HIGHER GRADE MATERIAL REQUIRED AS NOTED ON PLANS. DRAWN BY.' RAMEY 3.) FLOOR COVERINGS JUDGED TO REPRESENT AN UNUSUAL HAZARD SHALL MEET THE SAME TESTING INTERNAL PRESSURE COEFFICIENT ±0.18 DATE: 1 1/7/05 PROCEDURES AS REQUIRED FOR WALL AND CEILING FINISHES. BUILDING DESIGN CONDITION ENCLOSED ZONE 1 E 16.23 PSF CHECKED BY: C. BYRD 4.) MORTON BUILDINGS GENERAL SPECIFICATIONS APPLY UNLESS INDICATED DIFFERENTLY ON DATE: 1 1/23/05 ZONE 2E -21.13 PSF SPECIFIC JOB DRAWINGS OR SUPPLEMENTAL INFORMATION. ZONE 3E -14.42 PSF REVISED DATE., 1116107 5.) KYNAR 500 IS A REGISTERED TRADEMARK OF ATOFINA CHEMICAL, INC., HYLAR 5000 IS A ZONE 4E -13.49 PSF I HEREBY CERTIFY THAT THE STRUCTURAL DESIGN FOR REVISED DATE; TRADEMARK OF SOLVAY SOLEXIS. ZONE 5E 13.49 PSF THIS BUILDING WAS PREPARED BY ME OR UNDER MY REVISED DATE. (ALL FORCEESS ACT • MAIN W RESISTING SYSTEM DIRECT SUPERVISION AND THAT I AM A DULY CT NORMAL TO THE SURFACE) ZONE 6E -10.31 PSF LICENSED/REGISTERED PROFESSIO AL E +sr• REVISED DATE: CS2X4FK 07/05 (FOR ZONES SEE MWFRS ONELEVATIONS PAGE) ZONE 1 11.77 PSF Ow"e�,sh� (MAXIMUM VALUE SHOWN), ZONE 2 -1 4.71 PSF Q 4p • 'f' ZONE 3 -10.96 PSF �. qlo_� A ZONE 4 -10.06 PSF RONALD L. SUTTO, 1 P'Eo ZONE 5 9.80 PSF DATE:O� � �. SHEET INDEX * ROOF SNOW LOAD CALCULATIONS , � � .## SHEET# DESCRIPTION ZONE 6 -7.94 PSF Ps = 0.7 x Ce x I x Pg x Ct x Cs GI OF GI SPECIFICATIONS, SHEET INDEX, & Ce = SNOW EXPOSURE FACTOR = 1.0 ZONE 1 1 1.5, --18.2 PSF WARNING: ,`�'°'►o;,�y` BUILDING LOCATION PLAN ZONE 2 1 1.5, -31.8 PSF IT IS A VIOLATION OF NEW YORK STATE LAW F� ANY Sl OF S7 COLUMN PLAN I = IMPORTANCE FACTOR = 0.8 COMPONENT&CLADDING WIND LOADS PERSON UNLESS ACTING UNDER THE DIRECTION OF THE Pg = GROUND SNOW LOAD = 45 PSF (ALL FORCES ACT NORMAL TO THE SURFACE) ZONE 3 1 1.5, -31.8 PSF S2 OF S7 TRUSS PLAN, TRUSS DRAWING, 8, DETAILS Ct = THERMAL FACTOR = 1.0 (FOR ZONES SEE ELEVATIONS) ZONE 4 19.95, --21.6 PSF LICENSED ARCHITECT OR LICENCED ENGINEER TO Cs = ROOF SLOPE FACTOR = 1.0 ALTER ANY ARCHITECTURAL OR ENGINEERING ITEM. S3 OF S7 ELEVATIONS & DETAIL S4 OF S7 SECTIONS & DETAILS Ps = 0.7 x 1.0 x 0.8 x 45 x 1.0 x 1.0 = 25.2 PSF ZONE 5 19.95, --26.7 PSF S5 OF S7 SECTIONS & DETAIL S6 OF S7 SECTIONS & DETAILS SCALE:AS NOTED S7 OF S7 SECTIONS, DETAILS, & SCHEDULES SHEET NO. Gl OF Gl OFFICE.' N N C14 N Q� CUTCHOGUE, NY .� a v � � 0.1 JOB NO. Z O Z O q ^ ��, �� L0 128-0765 0 = Z f- DZ J W cn —j W 05 yj O :27'-4 1/2" 7'-6" 7'-6" 7'-6" 7'-6" 7'-6" 7'-6" 7'-4 1/2"U = Up J O QQ OZ 1'-0"VENTED SIDEWALL OVERHANGS 0 03 � I o � Q 0Q U v UO W UO V-0"NON-VENTED ENDWALL OVERHANGS J J /.ice N 16"R A )16 — 6L 24"R(ABOVE) 24"R 24"R (ABOVE)24"R 24"R (ABOVE)24"R 24"R m 37-101/2" I O Z 10 34'-10 1/2" - L 6"R E E o Z O B COLUMN PLAN LEGEND ❑ - 3-2x6 LAMINATED COLUMN LOCATION 1 , - 3068 PLAIN, FLAT SLAB FIBERSTEEL WALKDOOR Ll.a N 27'-10 1/2" - 6"R W/LEVER LOCKSET, SINGLE CYLINDER DEADBOLT, ` V& CLOSER - 6068 9-LITE FLAT SLAB FIBERSTEEL WALKDOOR W/ ( 1 1 16 R 23'-10 1/2" LOCKSET `"'� C A- (3) 4429 VINYL SLIDING HAYFIELD WINDOWS uJ 7 S5 i I S? i (2) 14'xl4' INSULATED OVERHEAD DOORS W/ r ^ L 20'-10 1/2" 16}}'R O 7"x7" JAMB PROTECTORS & OPERATORS " ) 18'-5 1/2" 18' 6 1/4" 16"R 30"R 30"R 24"R .� r ^ 16 R1/2" O-87/16' OSB SHEAROWALL (SEE PAGE S5 OF S6 FOR 17'-10 ' - '-V 16'-4 1/2 1 6"R gs: DETAILS) v E E -30"x30" ATTIC ACCESS (VERIFY LOCATION) i .; N 13'-10 1/2" - 6'R S6 S6 Z ALL STEEL FASTENED W/STAINLESS STEEL SCREWS o ., � s 4 16"R - 16" DIAMETER FOOTING W/ � O 8"THICK MINIMUM READ]-MIX CONCRETE BELOW BOTTOM OF LOWER COLUMN WITH 7'-10 1/2" - — I 16"R I ADDITIONAL READI-MIX TO TOP OF 218M STILT (9"±). o PLACE CONCRETE BELOW AND ABOVE BOTTOM OF 6-10 1/2"—,"- 16"R DTSS A I LOWER COLUMN IN ONE OPERATION. cy S4 24"R- 24" DIAMETER FOOTING W/ o R 3'-10 1/2" 16" 36"R 36"R 24"R 24"R 24"R 24"R 10"THICK MINIMUM READI-MIX CONCRETE I \ I \ I I I \ I I BELOW BOTTOM OF LOWER COLUMN WITH �•/ v 24"R 24"R 16"R ►.J 0'-0" 0'-0" — — 0,-01 ADDITIONAL READI-MIX TO TOP OF 224M STILT (PLACE CONCRETE BELOW AND ABOVE BOTTOM 9'±). �J -�J F— z0 OF LOWER COLUMN IN ONE OPERATION. w SOUTHEAST SIDEWALL COLUMN I I I I I I 30"R-30" DIAMETER FOOTING W/ > = O LOCATION DIMENSIONS 7-4 1/2" 1 7-6" 1 7'-6" i 7-6" 7'-6" 1 7'-6" i 7'-6" 1 7-4 1/2" 13"THICK MINIMUM READI-MIX CONCRETE BELOW BOTTOM OF LOWER COLUMN WITH ADDITIONAL READI-MIX TO TOP OF 230M STILT (9"±). o N iv iv iv N N i\ - PLACE CONCRETE BELOW AND ABOVE BOTTOM X ^ ^ 0` OF LOWER COLUMN IN ONE OPERATION. o O 36"R-36" DIAMETER FOOTING W/ 00 N � N 16"THICK MINIMUM READ]-MIX CONCRETE ' ^ �t N � c'') VV � 0 �f BELOW BOTTOM OF LOWER COLUMN WITH ADDITIONAL READI-MIX TO TOP OF 236M STILT (9"±). (� PARTITION COLUMN PLACE CONCRETE BELOW AND ABOVE BOTTOM Z LOCATION DIMENSIONS 7'-4 1/2" i 7-6" i 7'-5 1/4" 37-5 1/4" OF LOWER COLUMN IN ONE OPERATION. Q N w CL o04 ` M o O O ^ v O c� - UJ O ^ O\ CV V N COLUMN PLAN ROUGH OPENING SCHEDULE UNIT SYMBOL WIDTH HEIGHT FROM LEGEND 38 1/4" 81" DRAWN SY: RAMEY Di 52 1/4" 33 5/8" DATE: 1 1/7/05 CHECKED 8Y.' C. BYRD DATE: 1 1/23/05 REVISED DATE.' 1/16/07 REVISED DA TE.' REVISED DA TE: REVISED DATE.' 01 . 1q . -I 2' 8' SCALE.-AS NOTED SCALE: R SHEET NO. 11 4' 16' 1 OF S 7 OFFICE.' 3 [— CUTCHOGUE, NY TRUSS / BRACING PLAN LEGEND JOB NO. 128-0765 2 42' LL S.C. TRUSSES @ 7-6" O.C. TYPICAL a - 2x6 DIAGONAL END BRACES APPROXIMATELY (2) 20d R.S. NAILS IN OVERHANG FRAME 7-0" O.C. TYPICAL 0 - CONTINUOUS 2x4 LOWER CHORD TRUSS TIES 2x4 BEV. PURLIN o i APPROXIMATELY 3'-6" O.C. TYPICAL TOE NAIL OVERHANG RAFTER ' TO OVERHANG NAILER WITH X � A -- — (1) 16d R.S. NAIL EACH SIDE 'O S2 C. B � � O I OVERHANG FRAME S2 a Z END TRUSS 2x6 OVERHANG NAILER w o 0 Z (7) 20d R.S. NAILS O z END TRUSS CL 4 ,O . . . . . . , : : , 0 : 3-2x6 CORNER COLUMN O O O O O O O I J o I ' 3 o a ; I DETAIL #A Uj z I • • I SCALE: 1 1/2" a • 6-20d R.S. NAILS v J 0 , ( PER CONNECTION >: 2-2x6 END COLUMN EXTENSION o o DETAIL # B U o SCALE: 1 1/2"= 1'-0" F— 12 U U ° -- - - - - - - - - - - - - - - - - - - - -1 >>°r --� Wz TRUSS / BRACING PLAN Q2x4PURLIN o 60d R.S. NAIL 60d R.S. NAIL II P V O O 20 GA. GALVANIZED C° TOP TRUSS CHORD o \ PURLIN CONNECTOR (� Q Q �.J ©OUSP RT4 HURRICANE ANCHOR \ � O FASTENED TO TRUSS AND PURLIN \ Z W/(4) 0.131"x 1 1/2" R.S. NAILS Z 0' .o l 1 1 0 0° 20 GA. GALVANIZED aU PURLIN CONNECTOR a®/ RUSS a' \ � (1) #9x1"TRU-GRIP SCREW ON PEAK SIDE AND 1 I 1 10x15 PL. (2) #9x1"TRU-GRIP SCREWS ON EAVE SIDE OF �� 6'-10 1/4" PURLIN IN HOLES SHOWN (JOINT MUST BE TIGHT _J 0000°°ao 13'-8 1/2" BEFORE FASTENING CLIPS) O O ° 000 (1) #9x1"TRU-GRIP SCREW ON PEAK SIDE AND •o o ° °oo (2) #9xl"TRU-GRIP SCREWS ON EAVE SIDE OF ® °°000000 ° oo PURLIN IN HOLES SHOWN (JOINT MUST BE TIGHT ° °° BEFORE FASTENING CLIPS SQ2x4 PURLIN 2x4 BUTTED PURLIN DETAIL x4 BUTTED PURLIN DETAIL ° o. DRAWNBY: RAMEY 0 1 1 x'15 PL. ° ° ' o-o DATE.- 1 1/7/05 o °° WEB #1 °°° ° CHECKED 8Y: C. B Y R D TRUSS DESIGN SPECIFICATION: g,_g:, 2x4 WEB T C' #2 DATE: 1 1/23/05 Truss has been designed by computer using the Purdue STIFFENER Plane Structure Analyzer IAW current standards and 12 REVISED DATE: 1/16/07 specifications of recognized engineering principles. #2 3x5 PL. �Trusses are manufactured by Morton Buildings, Inc. WEB WEB #3 4 REVISED DATE.REVISED DATE; LUMBER SPECIFICATION (2001 NDS for Wood Construction): 2klp 16x9 PL. 18 GA. REVISED DATE, Lower Chord -- 1950f- 1.5E MSR Southern Pine Top Chord --- 1950f- 1.5E MSR Southern Pine WEB #4 13x8 PL. 18 GA. MW"r:, Top Chord --- No. 1 K.D. - 19 Southern Pine 16xl0 PL. 13x8 PL. 15x5 PL. 00000 o° 18 GA. oN000a 000°000 000° ° �Q• ' Web Members -- No. 1 K.D. - 19 Southern Pine 4X5 PL. 18 GA. oo°° 11 lxl 1 PL. 18 GA. �'� SGrO�fi 00 00 4X5 PL. °oo 0 9x9 PL. 4X5 PL. H.B. 00*ooa°°oo °000 °O0000 0000O: o _ 000 oa0000 o° ' 00 ° o 0 000 ooa000 oo0000 000 000000 ' 00 0° o 0 00 TRUSS PLATE SPECIFICATION (ICBO Evaluation report No. 2929): °°°°°° °°°°° o°° °°°°°°°°° °° °° oo° °°°° ° °0 2x4 0° 15 0000000° °°°°°° 1/2"°°oo°° °°°oo ° 0000°°°°°° o °°oo°° ° 000°oo °°ooc°°°°°° °°°°°°° LOWER CHORD o°° °°°4X5 PL. O N °°°°°° °°o°oo °oo°°°°°°° 4X5 PL. 2x6 0°°°°°°°°°a° °°°°° •O °°°o°° °oo o° °°°°°° °°° 2. A TM A-653, Grade A 20 Ga. and 18 Ga. where noted, °°o°°_ � •� galvanized steel Morton truss plates identified by a . hexagon stamped every 1 1/4"along the center of the plate CAMBER AT • 5-0 1/4" RAFTER LENGTH 22-0 1/16" = O� Webs are 2x4's TRUSS SPACING 7'-6" O.C. CENTERLINE 1 1/4" 12-2 13/16" LIVE LOAD 26 PSF `► DEAD LOAD 4 PSF 20'-10 1/2" 2' 8' CEILING LOAD 2 PSF 42' LL S .C. TRUSS ALE: TOTAL LOAD 32 PSF SCALE.•AS NOTED 1' 4' 16' SCALE: 1/2"= V-0" SHEET NO. LS2 OF S7 OFFICE. CUTCHOGUE, NY JOB NO. 4.2' WIDE 4.2' WIDE 128-0765 (ZONE 2 & 3) (ZONE 2) (ZONE 2 & 3) y�~ (ZONE 1) VENT-A-RIDGE QQ (ZONE 3) /777 T �� o (ZONE 2) ch (ZONE 3) / a_ N 0 5"O.G.GUTTERS m 4 6 O Z IN / a HI-RIB STEEL J a/ w 3 : , 6E — T#21 CORNER TRIM O i; 4 E ( °- 2 o T#167 TRANSITION TRIM L 1 HI RIB STEEL WAINSCOT 5 T#21 CORNER TRIM T#167 BASE TRIM Lu 1 E ►..J7 MWFRS w 4.2' WIDE 51.6' WIDE (ZONE 4) 4.2' WIDE tQ Z Reference (ZONE 5) (ZONE 5) " J Corner NORTHWEST ELEVATION U 4.2' WIDE 4.2' WIDE (ZONE 2 & 3) (ZONE 2 & 3) 4.2' WIDE 12 T#16 GABLE TRIM 4.2' WIDE 12 — T#16 GABLE TRIM 0 . (ZONE 2 & 3) 4 (ZONE 2 & 3) 4 r 1 --•1 LU - O Z U lI HI-RIB STEEL HI-RIB STEEL �"� T421 CORNER TRIM T#21 CORNER TRIM O zm T#167 TRANSITION TRIM T#167 TRANSITION TRIM HI RIB STEEL WAINSCOT HI-RIB STEEL WAINSCOT Z 7777777 T#21 CORNER TRIM T#21 CORNER TRIM 1 1 1 = T#167 BASE TRIM T#167 BASE TRIM N w CL 0 4.2' WIDE 33.6' WIDE (ZONE 4) 4.2 WIDE 4.2' WIDE 33.6' WIDE (ZONE 4) 4.2 WIDE LJLJ 0 (ZONE 5) (ZONE 5) (ZONE 5) (ZONE 5) SOUTHWEST ELEVATION NORTHEAST ELEVATION aC 4.2' WIDE 4.2' WIDE (ZONE 2 & 3) (ZONE 2) (ZONE 2 & 3) DRAWN BY: RAMEY (ZONE 3) (ZONE 1) VENT-A� RIDGE(i Q DATE.' 1117105 CHECKED BY.' C. BYRD (ZONE 2 ) / DATE: 1 1/23/05 (ZONE 3) REVISED DATE.' 1/16/07 REVISED DATE.' 5"O.G. GUTTERS REVISED DATE.' REVISED DATE.' HI-RIB STEEL n°uu►.s _ T#21 CORNER TRIM '��'� u " 'O T#167 TRANSITION TRIM HI-RIB STEEL WAINSCOT T#21 CORNER TRIM T#167 BASE TRIM 1 4.2' WIDE 51.6' WIDE (ZONE 4) 4.2� (ZONE 5) (ZONE 5) 2' 8' SOUTHEAST ELEVATION SCALE:AS NOTED SCALE: SHEET NO. 4 16 S3 of S7 OFFICE: CUTCHOGUE, NY JOB NO. s FF2000 HI-RIB STEEL 128-0765 (5 2x4 PURLINS @ 24" O.C. (NO. 2 SPF) FF2000 HI-RIB STEEL INSULATION STOP/ GABLE PURLIN FLASHING AIR DEFLECTOR T#16 GABLE TRIM 2x4 PURLINS @ 24" O.C.Q 16 (4) 2 1/4" R.W. OR 16d R.S. NAILS (NO. 2 SPF) 2x4 BEV. PURLIN 2x6 FASCIA o FILLER STRIP v `r co 2x6 BEV. FASCIA a T# 194 TRIM --� USP RT4 HURRICANE �— (1) 20d R.S. NAIL THROUGH STRAP N RT4 HURRICANE ANCHOR©Q O, 5" O.G. GUTTERS --�' 19 ® SOFFIT ANCHOR & INTO BRACE ` O _ 2' END BRACE STRAP W/ PRE-PUNCHED � i T#144 & 146 FASCIA TRIM 42' LL S.C. TRUSS ® HI-RIB/SOFFIT CAP TRIM i HOLES (BEND TO FIT) FASTENED W/ w 9 0o SOFFIT (3) 1 1/2" R.S. NAILS R-19 INSULATION 42' END TRUSS i O ZD HI-RIB/SOFFIT CAP 4 MIL VAPOR RETARDER 2x6 DIAGONAL BRACING FASTENED w 2x6 OVERHANG NAILER INTERIOR HI-RIB STEEL 2-2x6 E.C.E. i / TO COLUMN W/(4) 1 bd R.S. NAILS I� O 2 1/2"x5 1/2" M. BOLTS & 2x4 TOP BLOCK &T#11 �" i 42' LL S.C. TRUSS C ( ) Is KYNAR HI-RIB STEEL (8) 20d R.S. NAILS 2x4 TRUSS TIE r D FIBERGLASS INSULATION UTILIZED � — ` _ _ — _ _ _ i _ -- — LL,J `�../ AS FIRE BLOCK AS ALLOWED IN ADDL. 2x6 NAILER IBC SECTION 716.2.1 LjLj 3-2x6 LAMINATED COLUMN \_ J l I 1 O INTERIOR HI-RIB STEEL Q Z )e KYNAR HI-RIB STEEL rr^^ - \_ INTERIOR HI-RIB STEEL 2x4 L-NAILER W/T#136 & T#11 ry JJ " J 2x4 STRIPPING @ 32"O.C. ii: (4) ROWS 2x4 NAILERS 14 - (2100f MSR SPF) 16'-0" GRADE TO HEEL T#167 TRANSITION TRIM 2x4 STRIPPING @ 24"O.C. TO 8'-0" 3-2x6 LAMINATED COLUMN 1 " 1 " ,o 1 /4xl /4xl4 GA. SUPPORT ANGLE F— 10 6" BLANKET INSULATION W/ V ( 1 10 � 4 MIL VAPOR RETARDER TRUSS IN COLUIMN FASTENED TO COLUMN AT EACH �./ _j 3/4" PLYWOOD SADDLE CORNER WITH (3) .148"0 x 2" J l l l Z LAMINATED COLUMN STAINLESS NAILS. (12 TOTAL NAILS `J F— O PER COLUMN) � � O 2x2 VERTICAL BLOCKING 14 GA. CHANNEL WITH 1/4" PLATED '2 AT COLUMN LOCATION RIVET TO SUPPORT ANGLE T#167 TRANSITION TRIM UNDISTURBED SOIL Lj__ 2x6 NOTCHED NAILER Q x KYNAR HI-RIB STEEL WAINSCOT STILT NOTES z 7/16" OSB PROTECTIVE LINER 13 1. INSTALL PRESSURE TREATED 1'1 LOWER COLUMN WITH STILT IN T#167 BASE TRIM W/L-CAP TRIM PROTECTOR ,a THE AUGURED HOLE. Z II (1) ROW 2x8 TREATED SPLASHBOARD �' ° 2. POUR MINIMUM THICKNESS OF 1 1 1 2x4 NON-TREATED BASEBOARD Q 15� READI-MIX CONCRETE INTO THE w 1 1/2"xl" BLOCK & T#109 BASE TRIM HOLE AS SPECIFIED. a 18" LOWEST 6"CONCRETE FLOOR :.: ::: A P 0 MEMBER CUT-OFF 4' WIDE R-11 PERIMETER INSULATION♦ 3 B CKFILL AND COMPACT THE 1 1 1 81 M BASE ANCHOR to ANNULAR SPACE AROUND THE q STILT ISOMETRIC COLUMN TO GRADE WITH SOIL T AUGURED FROM THE SITE. FINISH GRADE Q ' MINIMUM COMPACTED GRANULAR BASE+ 2x6 TREATED BOTTOM PLATE CONCRETE FLOOR NOTES I.)3500 PSI,5 1/2 BAG MIX CONCRETE. 2.)REINFORCING:6x6-1Ox10 WWM. 4'-0" 3.)SLOPE GRADE AWAY FROM BUILDING @ 1"PER FOOT FOR A MINIMUM DISTANCE OF IO'PLUS DRAWN BY: RAMEY OVERHANG WIDTH. 4.)WHEN A VAPOR RETARDER IS PROVIDED,PLACE A DATE., 1 1/7/05 MINIMUM 6 MIL POLYETHYLENE VAPOR RETARDER ON TOP OF A MINIMUM 4"COMPACTED GRANULAR BASE AND DIRECTLY BELOW THE CONCRETE FLOOR. -"-�—`� a 81 M BASE ANCHOR 0 CHECKED BY: C. BYRD a 224M (14 GA.) COLUMN STILTQQ T ° DATE., 1 1/23/05 10"THICK MINIMUM READI-MIX CONCRETE REVISED DATE: 1116107 BELOW BOTTOM OF LOWER COLUMN WITH FINISH GRADE ADDITIONAL READI-MIX TO TOP OF 224M STILT (9"±). — REVISED DATE: NOTE: PLACE CONCRETE BELOW AND ABOVE BOTTOM NOTE: FOOTINGS ARE DESIGNED FOR A 24"O OF LOWER COLUMN IN ONE OPERATION. THIS SECTION IS THE SAME AS REVISED DATE. 2000 PSF SOIL BEARING CAPACITY. LOCAL CONDITIONS MAY REQUIRE SECTION "A" EXCEPT FOR REVISED DATE; MODIFICATIONS, THE ITEMS AS NOTED. SIDEWALL SECTION A 218M (14GA.) COLUMN STILT D VL ���- SCALE: 1/2" - 1' 0" 8"THICK MINIMUM READI-MIX CONCRETE 3* BELOW BOTTOM OF LOWER COLUMN WITH ' ADDITIONAL READI-MIX TO TOP OF 218M STILT (9"±). "� •• 16"Q� PLACE CONCRETE BELOW AND ABOVE BOTTOM OF (I LOWER COLUMN IN ONE OPERATION. NOTE: ♦ IDENTIFIES ITEMS THAT ARE NOT PROVIDED BY MORTON BUILDINGS, INC. OR MORTON EN DWALL SECTION B BUILDINGS' SUBCONTRACTORS AND ARE THE OWNER'S RESPONSIBILITY. SCALE: 1/2" = 1'-0" SCALE:AS NOTED SHEET NO. S4 OF S7 ICOFFICE: - CUTCHOGUE, NY :2x4 BLOCKS (BOTH SIDES OF TRUSS) JOB NO. (BUTT TO COLUMN AND NAIL TO TRUSS) 128-0765 R-19 INSULATION LOWER CHORD OF TRUSS 2x4 L-BLOCK (NAIL TO o ia TRUSS AND 2x4 BLOCK. DO NOT NAIL TO COLUMN.) m .9 :�� �_ � FF2000 HI-RIB STEEL o, 2x4 BLOCKS BETWEEN PURLINS INTERIOR HI-RIB STEEL f� M T#129 TRIM (STITCHED TO HI-RIB � Lu lox FIBERGLASS INSULATION UTILIZED @ 3'-0" O.C.) AS FIRE BLOCK AS ALLOWED IN T#66 TRIM (TRIMMED TO 4 1/2" ) O IBC SECTION 716.2.1 Z CONTINUOUS 2x4 PURLINS Z 2x4 TOP NAILER O INTERIOR HI-RIB STEEL (FASTEN STEEL TO THIS NAILER) a: (FOR S.C. TRUSS STEEL SET AT 42' LL S.C. TRUSS CL NOTE: HEEL HEIGHT MINUS 1") w CD TRUSS IN COLUMN SADDLE. 7 DO NOT NAIL COLUMN TO 2x4 TOP BLOCK 2x6 END COLUMN EXTENSION Z TRUSS. R-19 INSULATION WITH 4 MIL VAPOR RETARDER 2x4 TOP BLOCK J ( 1 1 DETAIL # 1 FIBERGLASS INSULATION UTILIZED I 1 1 o SCALE: 1" = V-0" AS FIRE BLOCK AS ALLOWED IN Z IBC SECTION 716.2.1 42' LL S.C.TRUSS (/� t../ ° INTERIOR HI-RIB STEEL T#11 AND T#136 TRIMS J L.1_i 2x4 TOP NAILER ?` SEE DETAIL #1 2x4 STRIPPING INTERIOR HI-RIB STEEL INTERIOR HI-RIB STEEL INTERIOR HI-RIB STEEL =' NOTE: --.J F- O♦IDENTIFIES ITEMS THAT ARE NOT PROVIDED 2x4 BASEBOARD 2x4 BASEBOARD BY MORTON BUILDINGS, INC. OR MORTON = O BUILDINGS' SUBCONTRACTORS AND ARE THE 1 1/2"xl"BLOCK W/T#167 & T#15 ! 1 2x4 BASEBOARD OWNER'S RESPONSIBILIITY. `J 1 1/2"xl" BLOCK W/T#167 &T#15 ♦3/4"T&G PLYWOOD DECKING U, a/ o 3/4"T&G PLYWOOD DECKING* T#167 TRANSITION TRIM 12"TJI/H90 JOISTS @ 12" O.C.♦ Z co T#167 TRANSITION TRIM ♦♦I-JOIST HANGERS 12"TJI/H90 JOISTS @ 12" O.C. �-/ 2xl2 RIM JOIST 3-2x6 LAMINATED COLUMN 3-2x6 LAMINATED COLUMN 1 1 1 2xl0/2x8 EXTERIOR WALL HEADER--A. w FASTENED (21) 20d R.S. NAILS Lu v> 2x6x20" HEADER SUPPORT BLOCK 3/4" PLYWOOD o I 1 1 W/(26) 20d R.S. NAILS 3/4" PLYWOOD _1 (1) ROW 2x4 STRIPPING FASTENED 2x2 VERTICAL BLOCKING AT —� W/39Q CLIP 2x4 STRIPPING @ 24"TO 8'-0" txCOLUMN LOCATION Q GRADE TO 2x4 STRIPPING 6" BLANKET INSULATION WITH BOTTOM OF JOIST 4 MIL VAPOR RETARDER DRAWN 8Y. R A M E Y 2x4 NON-TREATED BASEBOARD DATE.' 1 1/7/05 INTERIOR HI-RIB STEEL 1 1/2"xl" BLOCK WITH CHECKED 8Y. C. BYRD 2x4 NON-TREATED BASEBOARD T#109 BASE TRIM DATE.' 1 1/23/05 1 1/2"xl" BLOCK W/T#109 6" CONCRETE FLOOR REVISED DATE.• 1116107 CONCRETE STOP 2x6 TREATED BOTTOM BLOCK REVISED DATE: 9 a° ;.• . '. REVISED DATE.' 2x6 TREATED BOTTOM PLATE x REVISED DA TE. NOTE: 4'-0" >r N+�1lY �►i THIS SECTION IS THE SAME AS ���• ' ' ,y©� ' SECTION "A" EXCEPT FOR �4 N THE ITEMS AS NOTED. co � +0 �o 230M (14 GA.) COLUMN STILT ' ' 13"THICK MINIMUM READI-MIX CONCRETE 236M (14 GA. 14 GA.) COLUMN STILT •.'. .A' � ..'. :�• � '•) COLUMN STILT 230M ( BELOW BOTTOM OF LOWER COLUMN WITH . : '�: '•.• '• a a .� ,¢` 16"THICK MINIMUM READI- a 13"THICK MINIMUM READI-MIX CONCRETE ADDITIONAL READI-MIX TO TOP OF 230M STILT (9"±). ��, r r MIX CONCRETE BELOW BELOW BOTTOM OF LOWER COLUMN WITH PLACE CONCRETE BELOW AND ABOVE BOTTOM ' : ..4 BOTTOM OF LOWER , ADDITIONAL READI-MIX TO TOP OF 230M STILT (9"±). OF LOWER COLUMN IN ONE OPERATION. 30"0 A. COLUMN WITH ADD'L READI- I PLACE CONCRETE BELOW AND ABOVE BOTTOM a MIX TO TOP OF 236M STILT OF LOWER COLUMN IN ONE OPERATION. 36"0 (9"±). PLACE CONCRETE 30"0 SIDE ALL SECTION C PARTITION SECTION D BELOW AND ABOVE BOTTOM SCALE.•AS NOTED OF LOWER COLUMN IN ONE SCALE: 1/2" = V-0" SHEET NO. OPERATION. SCALE: 1/2" = 1'-0" S 5 OF S 7 OFFICE: CUTCHOGUE, NY 4.2' WIDE JOB NO. 128-0765 (ZONE 2 & 3) 0 U v 2x4 PURLINS @ 20"O.C. — • 10 0_ N o, 0 M RT4 HURRICANE ANCHORS 2x6 UPRIGHT [L 2x4 TOP BLOCK & T#11/136 m TRUSS TOP CHORD 2x10 HEADER O FLAT STEEL Z 2x6 NAILER r1� Z 2x6 BLOCK 2x12 HEADER 4.2' WIDE O T#124 T#15 NOTE: IL T#129 �� O.H.D. RT'4 CLIPS TO BE USED ON FIRST ROW (ZONE 2 & 3) CD CIF PURLINS FROM SIDEWALL, FIRST LLJ Z 2x2 BLOCK THREE ROWS FROM PEAK, AND AT T#151 ALUMASEAL PURLIN TO END TRUSS. _ T#154 -- i� T#105 42' PURLIN LAYOUT '`� w 2x3 JAMB (BEYOND; 14'-3" GRADE TO BOTTOM SCALE: 1/2" = 1'-0" r ^ z BOTTOM 2' TREATED) (3) 2x6 JAMB COLUMN (BEYOND) OF 2x6 BLOCK C 2x6 TRACK BLOCK (BEYOND; * '::.;..: BOTTOM 2' TREATED) OHD HEADER SECTION E ''2', �= z ^ � SCALE: 1 = 1'-0" 2x4 TRUSS TIE II 60d R.S. NAIL 20 ga. GALVANIZED V .o LOWER TRUSS CHORD PURLIN CONNECTOR LOWER CHORD OF f— p 7/16"OSB END TRUSS � � = O o o �_; STD. 2x4 BUILDING c , NAILERS @ 24" O.C. - - - - - - - - - - - - - - - - • _ _•— _ _ — _I — — — — — — — — — — — — — — — — — — a� x (1) #9x1"TRU-GRIP SCREWS ON PEAK SIDE AND m 2x6 VERTICAL BLOCKS @ (2) ON EAVE SIDE OF PURLIN IN HOLES SHOWN. Z O COLUMN BETWEEN NAILERS (JOINT MUST BE TIGHT BEFORE FASTENING CLIPS) CD CL - - = = - - - = - - - -= —'- - - - - v-� z ADDITIONAL 2x6 NAILER 2x4 TRUSS TIE DETAILLu W N oc PERIMETER OF OSB SHEETS _ _ _ _ _ _ _ _ _ _ _ _ ------- _ _ NAILED W/1-3/4"SHINGLE Q N GUN NAILS SPACED 3"O.C. 20d R.S. (NAIL THROUGH 00 STRAP INTO TIE 1 1 1 (3) 1 1/2' R.S. NAILS die 2' LONG END BRACE STRAP _ —.- - - -.- - - _•_ - - _.- - - -•— THROUGH STRAP OSB NAILED TO INTERMEDIATE d (4) 2 1/4" R.W. NAILS SUPPORTS W/1-3/4"SHINGLE GUN NAILS SPACED 6"O.C.® DRAWN BY.- RAMEY DATE: 1 1/7/05 — — — — — — — — — — — — — LAMINATED COLUMN 2x4 TRUSS TIE CHECKED BY: C. BYRD DATE; 1 1/23/05 REVISED DATE: 1116107 - - - - - - - - - - - - - - - - - - 2x4 TRUSS TIE TO ENDWALL DETAIL REVISED DATE.' 5/4x6 NAILER REVISED DATE.• REVISED DATE: — 2x8 TREATED BASEBOARD 2x6 BLOCK BETWEEN NAILERSpF 1. NAILED TO COLUMN W/20d '�� •,� - - - - - - - - - - - - - - - - - - GUN NAILS. NAILED 3" O.C. Q * ,0 p. 2x4 NAILERSr .� 7/16" OSBt LAMINATED COLUMN OSB SHEARWALL DETAIL LAMINATED COLUMN SCALE: 1/2" = 1'-0" OSB SHEARWALL ELEVATION SCALE: 1/2" = 1'-0" SCALE:AS NOTED SHEET NO. S6 OF S7 OFFICE: CUTCHOGUE, NY JOB NO. 128-0765 ROOF STRUCTURE FASTENING SCHEDULE U o � VENT-A-RIDGE TO RIDGE BASE TRIM #9 x 1"STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS @ 8" o.c. �. RIDGE BASE TRIM TO 2x4 PURLINS #9 x 2"STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS AT EVERY HI-RIB (1'-0" o.c.) a_ � HI-RIB STEEL TO 2x4 PURLINS #9 x 2"STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS AT EVERY HI-RIB (1'-0"o.c.) � 20 ga. GALVANIZED PURLIN CONNECTORS #9 x 1"TRU-GRIP SCREWS M sO 2x4 PURLINS TO TRUSS 0.200"x 6" (60d) RING SHANK NAILS IN PRE-DRILLED HOLE m © RT4 HURRICANE ANCHOR TO 2x4 PURLINS (4) 0.135 (8d) x 1-1/2" RING SHANK NAILS O Qi RT4 HURRICANE ANCHOR TO TRUSS (4) 0.135 (8d) x 1-1/2" RING SHANK NAILS Z ®T 2' LL STRAIGHT CHORD TRUSS TO COLUMN (2) 1/2"x5 1/2" MACHINE BOLTS rr1� O (8) 0.177"x 4" (20d) RING SHANK NAILS V = w W V z . Q w WALL FRAMING FASTENING SCHEDULE cry 0 COLUMN STILT (14 GA.) TO COLUMN (12) 0.148"x 2" (6d) STAINLESS STEEL RING SHANK NAILS Z io 81 M BASE ANCHOR TO COLUMN 0.177"x 2-1/2"STAINLESS STEEL NAILS 4 PER ANCHOR i 2x8 SPLASHBOARD TO COLUMN (4) 0.177"x 4" (20d) STAINLESS STEEL RING SHANK NAILS @ SPLICE/ (3) 0.177"x 4" (20d) RING SHANK NAILS @ STANDARD CONNECTION 2x6 NOTCHED NAILER TO COLUMN (4) 0.148"x 3-1/2" (16d) NAILS @ SPLICE/ (3) 0.148''x 3-1/2" (16)d) NAILS @ STANDARD CONNECTION �3 7/16" OSB TO SPLASHBOARD & NOTCHED NAILER 0.099"x 1-1/4" ASBESTOS SIDING NAILS a/"I is 2x4 NAILER TO COLUMN (4) 0.148"x 3-1/2" (16d) RING SHANK NAILS @ SPLICE/ (3) 0.1418"x 3-1/2" (16d) RING SHANK NAILS @ STANDARD CONNECTION o 0 END TRUSS TO 2-2x6 END COLUMN EXTENSIONS (6) 0.177"x 4" (20d) RING SHANK NAILS r\ F— �b 2x4 PURLIN TO END TRUSS 0.200"x 6" (60d) RING SHANK NAILS IN PRE-DRILLED HOLE V U RT4 HURRICANE ANCHOR TO END TRUSS (4) 0.135" (8d) x 1-1/2" RING SHANK NAILS "'�-� LJLJ Z �e HI-RIB STEEL TO NAILERS #9 x 2"STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS AT EVERY HI-RIB (1'-0" o.c.) --J F— O i9 SOFFIT TO WALL INSERTED IN PRE-FORMED SLOT IN SOFFIT/HI-RIB CAP > p ©o SOFFIT TO FASCIA T-50 MONEL STAPLES (2) PER PIECE �_; Q 7/16" OSB SHEARWALL - I Q OSB TO PERIMETER BLOCKS/ FRAMING 0.120"x 1-3/4"SMOOTH SHANK SHINGLE GUN NAILS @ 3" o.c. �" .� X ® OSB TO INTERMEDIATE FRAMING 0.120"x 1-3/4"SMOOTH SHANK SHINGLE GUN NAILS @ 6" o.c. O BLOCKS TO COLUMNS 0.131"x 3-3/4" (20d) SMOOTH SHANK GUN NAILS @ 3"o.c. (Z p _ O l I 1 = N Lt w N O #8x3 1/2" WOOD SCREWS FASTENED THROUGH THE WINDOW JAMB L L J o FLASHINGS INTO THE 2"x4" ROUGH FRAMING. PRE-DRILL HOLES 10" O.C. IN WINDOW JAMB FLASHINGS TO ACCEPT WOOD SCREWS. _J SCREWS ARE NOT REQUIRED IN THE HEAD OR THE SILL. O.S.B. SHEATHING IS 1" WIDER THAN THE WIDTH OF THE WINDOW FROM OUTSIDE OF TRIM TO OUTSIDE OF TRIM. O.S.B. SHEATHING IS 1"TALLER THAN THE HEIGHT OF THE WINDOW FROM OUTSIDE OF TRIM TO OUTSIDE OF TRIM. DRAWN 3Y: RAMEY DATE: 1 1/7/05 CHECKED 8Y: C. BYRD HEAD FLASHING 4 DATE.' 1 1/23/05 HEIGHT OF WINDOW 7/16" OSB PANEL �� REVISED DATE., 1116107 +1" REVISED DATE.• 7/16" OSB PANEL #8 x 3 1/2" WOOD FINNED WINDOW REVISED DATE: FINNED WINDOW SCREWS @ 10 O.C. REVISED DATE: SILL FLASHING y��ttwuta�� WIDTH WINDOW JAwIB FLASHING QF OF WINDOW 2"x4" ROUGH FRAMING ,��•4 S � +1 FIN WINDOW SECTION * FIN WINDOW JAMB DETAIL e WINDBOURNE DEBRIS PROTECTION SCALE:AS NOTED — FIN TYPE WINDOW SHEET NO. S7 OF S7 RETAIN STORM WATER R(INn)•F VEEC'THE FF,; OF THE TOWN CODE. F"""� OFFICE:- CODES OF Ni','. - Y M CUTCHOGUE, NY MORTON BUILDINGS GENERAL SPECIFICATIONS �� �': J°e "°;2 �D AS 1'60 EED P ¢ 8 0765 F-- DATE: Z ► B.P. Z LAMINATED COLUMNS - NO. 1 OR BETTER SOUTHERN YELLOW PINE NAIL LAMINATED 3 MEMBER S4S �J CERTIFI ATION OF FEE:, -, F' _ ' m COLUMNS USED IN MORTON BUILDINGS ARE PRESSURE TREATED BELOW GRADE TO A RETENTION OF .8 NAILING & NOTIFY BUILDiI'w %r..';",P T�,l;=NT AT w ., C�NNECTIO�IS _ POUNDS PER CUBIC FOOT WITH CHROMATED COPPER ARSENATE TYPE III, OXIDE IN CONFORMANCE REQUI ED. 765-1802 s M! TO ` P,',! FOR THE a WITH USEPA GUIDELINES AND AWPA STANDARD C28. THE TREATED PORTION OF THE COLUMNT/ iJS; r 1 U <v EMBEDDED IN GROUND SHALL BE LAMINATED WITH STAINLESS STEEL NAILS. 1. FOUNDATi. N - T'�•0 REQUIRE •o o DO NOT U CES WITH FOF r^OUf( D C �; ' RETF lr :,'' i 0- 01 1�1� Ui�V 2. ROUGH - FRA1.s{ A & P f�, 3 ;.� ..:: «.>,�, O EXI T EY �Uh,SIN FOOTINGS AND ANCHORAGE - COLUMN HOLES ARE DUG A MINIMUM DEPTH OF 4'-8" BELOW GRADE `� 3 x51 UNDA„ ��, ► CCATICN a INSL.LAT:o,1 '" (� w BUILDING :'''� . FINAL - COto"i;".' 'T'ION PJiJST (SEE PLANS FOR DIAMETER AND DEPTH). COLUMNS WITH GALVANIZED SUPPORT STILTS ARE PLACED IN W/LOADING � BE COMPLf ;; 70;3 C.O. OCCUPANCY ORCD THE HOLE. CONCRETE (MINIMUM COMPRESSIVE STRENGTH 2500 PSI) IS POURED IN PLACE TO THE �O DOCK ALL CONSTrR'JClIOfJ SHALL MEET THE O Z SPECIFIED THICKNESS SEE PLANS FOR REQUIRED THICKNESS ABOVE AND BELOW THE COLUMN). THE °r� p REQUIREMENTS OF THE CODES OF NEW USE IS UNLAWF [�/ w C ( ) �� a FORK STATE. NOT RESPONSIBLE FOR 'VITHOUT CERTIF C ATE C.� ° COLUMN IS THEN BACKFILLED WITH SOIL AND COMPACTED AT 8" INTERVALS OR BACKFILLED WITH FI t CTIOl \ DESIGN OR CONSTRUCTION ERRORS. /� -QUIR REFOR °- CONCRETE (SEE PLANS). _ OPENING w F OCCUPANCY uj CD TREATED LUMBER - PRESSURE PRESERVATIVE TREATED LUMBER OTHER THAN LAMINATED COLUMNS ARE NO. 1 OR BETTER SOUTHERN YELLOW PINE AND CENTER MATCHED, PRESSURE TREATED TO A NET COMPLY W7H LL CODES OF RETENTION OF .6 POUNDS PER CUBIC FOOT WITH A CODE AND INDUSTRY APPROVED PRESERVATIVE NEW PORK STATE & TC NPJ CODES .,,j LL_i TREATMENT IN ACCORDANCE WITH AWPA STANDARD C2. AS R UI _L, ,ND CONDITIONS OF •172,1ND£RSIGNED,Pi1RSUAT3TTOSOtTff MONOLD OWNCODLSi CDO�' uJ 10U•2S4(h ACKNOi.EP,GES THAT THE CONDFITONS OF TttE SITE PLAN Z P SET FOr""`tN THE RFSOLt ON OF APPRO AL DATED N26038'30"W 'HOLD OWN ZBA O S 3N RE ,Ltm 011 (10 FRAMING LUMBER -SIDING NAILERS ARE 2x4 S4S OR 2x6 SPF NO. 2 OR BETTER SPACED APPROXIMATELY 12.00' SOUTHOLD TOWN PLANNING BOARD 1L PLEAASESE P IE r ^ r `'� J 36" O.C. WITH ALL JOINTS STAGGERED AT ATTACHMENT TO COLUMNS. ROOF PURLINS ARE 2x4 S4S NO. SOUTMOLDTOWNTRUSTEES /�t�'c �i�y� 2 OR BETTER ON EDGE SPACED APPROXIMATELY 24"O.C. ALL OTHER FRAMING LUMBER IS NO. 2 OR 31�i% 5-^Tn'LE DATE BETTER. N.Y.S.DEC GP- AU"iH'J!-;' USk;!'+nl'1 sO'1, ROB T:.14PPOVED BY � ROOF TRUSSES - FACTORY ASSEMBLED WITH 18 OR 20 GAUGE GALVANIZED STEEL TRUSS PLATES AS `iJcP� Zot',r1d OF SOUt'HOLb PLANNING BOARD =+� - p, PROPOSED ,2,cr2L.ff�-u ,ninel3r!�ia=.�L���'� \ REQUIRED AND KILN DRIED LUMBER AS SPECIFIED, IN-PLANT QUALITY CONTROL INSPECTION IS 42'x16'x60' - p TITLE DATE � Q CONDUCTED UNDER THE AUSPICES OF THE TPI INSPECTION BUREAU. TRUSSES ARE DESIGNED IN A. "��z`rrsrr>yATurl _ MORTON � � ck�= BUILDING uTB:The a;,provc��xie dv+✓cS� er! ! ,c' ,11-eva!id �r \ _ ACCORDANCE WITH CURRENT STANDARDS AND SPECIFICATIONS FOR THE STATED LOADING. 1` p Ap�;w 0�throe u��tt c �,�.Y:cvrl as per os G� V DISTANT TO ` p)� a� t y SIDING PANELS (KYNAR 500 / HYLAR 5000) -0.019" MIN., G90 GALVANIZED OR AZ55 GALVALUME, WITH � PROPERTY LINE --.I 1 I 1 Z AN ADDITIONAL BAKED-ON KYNAR 500 / HYLAR 5000 FINISH WITH A NOMINAL 1 MIL. PAINT THICKNESS G��P\� J F- O ON EXTERIOR. BUILDING LOCATION -PLAN F 0 ROOFING PANELS (FLUOROFLEX 200i)TM) -0.019"MIN. AZ55 GALVALUME WITH AN ADDITIONAL _✓��^;' 7.5' v3 0' BAKED-ON THICKNESS POLYURETHANE PRIMER AND KYNAR 500/ HYLAR 5000 TOPCOAT WITH A TOTAL SCALP; 3.75' 15' 60' x MINIMUM PAINT THICKNESS OF 2 MILS ON EXTERIOR. m - L O TRIM - DIE-FORMED TRIM OF 0.019"MIN., G90 GALVANIZED OR AZ55 GALVALUME STEEL ON GABLES, BUILDING DESIGN CRITERIA TYPICAL LUMBER SPECIFICATIONS - 2001 NDS O c� RIDGES, CORNERS, BASE WINDOWS, AND DOORS WITH SAME FINISH AS ROOFING OR SIDING PANELS. - - SIZE DESCRIPTION BENDING VALUE Fb 0 BUILDING CODE 2002 BUILDING CODE OF NEW YORK STATE Z 2x4 NO. 1 &2 SPF 1313 PSI � � 1 1 = USE GROUP 2x4 2100f MSR SPF 2100 PSI GUTTERS -5" K-STYLE, .030 HIGH TENSILE ALUMINUM GUTTER, KYNAR 500/ HYLAR 5000 FINISH TO MATCH VB Q w CONSTRUCTION TYPE VB 2x6 NO. 1 &2 SPF 1 138 PSI w TRIM, ON BOTH SIDES OF THE BUILDING. FLOOR AREA 2520 SQ FT 2x6 NO. 1 SYP 1650 PSI Q vi FLOOR LOAD 125 PSF 2x8 NO. 1 SYP 1500 PSI LLB g ADDITIONAL NOTES MEAN ROOF HEIGHT 21 FT 2x10 NO. 1 SYP 1300 PSI _I 1.) ALL PLOT PLANS AND RELATED DETAILS SHALL BE PROVIDED BY OWNER UNLESS INCORPORATED BUILDING CATEGCDRY IV 2x12 NO. 1 SYP 1250 PSI _ I AS PART OF THESE DRAWINGS. ROOF SNOW LOAD* 26 PSF ALL 1950f MSR SYP 1950 PSI 2.) ALL INTERIOR PARTITIONS AND ROOM FINISHES IF NOT INCLUDED WITH THESE DRAWINGS SHALL BE GROUND SNOW LCOAD 45 PSF 1 1/2"x16" LAMINATED VENEER LUMBER 2800 PSI PROVIDED BY OWNER, STANDARD FINISHES SHALL HAVE LESS THAN 200 FLAME SPREAD RATING AS WIND SPEED (V3S) 120 MPH 3 1/2"x15" GLU-LAM 1650 PSI 5 1/4"x16 1/2" GLU-LAM 2400 PSI REQUIRED BY ASTM E84 FOR ORDINARY CONDITIONS AND 25 OR LESS FOR EXITS, PASSAGEWAYS, WIND IMPORTANCE FACTOR 0.77 5 1/4"x19 1/2" GLU-LAM 2400 PSI AND CORRIDORS. EXPOSURE CATEGCJRY B NOTE: HIGHER GRADE MATERIAL REQUIRED AS NOTED ON PLANS. DRA RAMEY 3.) FLOOR COVERINGS JUDGED TO REPRESENT AN UNUSUAL HAZARD SHALL MEET THE SAME TESTING INTERNAL PRESSURE COEFFICIENT ±0.18 - DATE.- 1 1/7/05 PROCEDURES AS REQUIRED FOR WALL AND CEILING FINISHES. BUILDING DESIGN (CONDITION ENCLOSED ZONE 1 E 16.23 PSF f,�` CHECKED BY.' C. BYRD 4.) MORTON BUILDINGS GENERAL SPECIFICATIONS APPLY UNLESS INDICATED DIFFERENTLY ON ° >a DATE.- 1 1/23/05 SPECIFIC JOB DRAWINGS OR SUPPLEMENTAL INFORMATION. ZONE 2E -21.13 PSF �� r 5.J KYNAR 500 IS A REGISTERED TRADEMARK OF ATOFINA CHEMICAL, INC., HYLAR 5000 IS A ZONE 3E -14.42 PSF REVISED DATE.'ZONE 4E -13.49 PSF TRADEMARK OF SOLVAY SOLEXIS. I HEREBY CERTIFY THAT THE STRUCTURAL S N FOR REVISED DATE.: MAIN WINDFORCE RESISTING SYSTEM ZONE 5E 13.49 PSF THIS BUILDING WAS PREPARED BY ME OR UNDER MY REVISED DATE.- ZONE 6E -10.31 PSF DIRECT SUPERVISION AND THAT I AM A DULY (ALL FORCES ACT NORMAL TO THE SURFACE)CS2X4FK 07/05 LICENSED/REGISTER ROFESS19NAL,ENGINEER. REVISED DATE.' (FOR ZONES SEE MWFRS ON ELEVATIONS PAGE) ZONE 1 11.77 PSF 7 avN��at�� (MAXIMUM VALUE SHOWN) ° �► 111~Ilf�► y key ZONE 2 -14.71 PSIF ZONE 3 -10.96 PSF SHEET INDEX ZONE 4 -10.06 PSF �° ` ' "� • RONALD L. SUT 17,12 Ez. * ROOF SNOW LOAD CALCULATIONS ZONE 5 9.80 PSF DATE: `s G(� SHEET# DESCRIPTION ZONE 6 -7.94 PSF ' SPECIFICATIONS, SHEET INDEX, & Ps = 0.7 x Ce x I x Pg x Ct x Cs ZONE 1 1 1.5, --18.2 PSF G1 OF G1 Ce = SNOW EXPOSURE FACTOR = 1.0 WARNING: A � R ' �' BUILDING LOCATION PLAN ,I = IMPORTANCE FACTOR = 0.8 COMPONENT&CLADDING WIND LOADS ZONE 2 1 1.5, -31.8 PSF IT IS A VIOLATION OF NEW YORK STATE L "U�1°9P �NY S1 OF S6 COLUMN PLAN Pg = GROUND SNOW LOAD = 45 PSF (ALL FORCES ACT NORMA.TO THE SURFACE) ZONE 3 1 1.5, -31.8 PSF PERSON UNLESS ACTING UNDER THE DIRECTION OF THE S2 OF S6 TRUSS PLAN, TRUSS DRAWING, & DETAILS Ct = THERMAL FACTOR = 1.0 (FOR ZONES SEE ELEVATIONS) ZONE 4 19.95, --21.6 PSF LICENSED ARCHITECT OR LICENCED ENGINEER TO S3 OF S6 ELEVATIONS & DETAIL Cs = ROOF SLOPE FACTOR = 1.0 ALTER ANY ARCHITECTURAL OR ENGINEERING ITEM. S4 OF S6 SECTIONS & DETAILS Ps = 0.7x 1.0x0.8x45x 1,0x 1.0 = 25.2PSF ZONES 19.95, --26.7PSF S5 OF S6 SECTIONS & DETAILS S6 OF S6 SECTIONS, DETAILS, &SCHEDULES A I 1 55 j��/7{ �f�),ti�C� E 'II SCALE.,AS NOTED SHEET NO. G1 OFG1 OFFICE.' i� CUTCHOGUE, NY v o v � O� JOB NO. 1 v N N m Lo L0 128-0765 7'-4 1/2" 7-6" 7'-6" 7-6" 7-6" 7'-6" 7-6" 7-4 1/2" 1'-0"VENTED SIDEWALL OVERHANGS APPP oVED o 1'-0"NON-VENTED ENDWALL OVERHANGS PLAIl1l " ?, U TOWN OF SOUTHOLD �`— a - - - - - - - - - - - - - - 0 41 '_9" 41 ' 9" - --- -- -- DATE Q_ ---Q- 16"W 0 16"W I �(ABOVEj ' „� (ABOVE)/ ' (ABOVE)' ' 16 R ��� 24 R 24'R 24 R 24 R 24 R 24 R 24 R �-�-- 38'-10 1/2' w Z 'O C C f—l/ w 34'-10 1/2" — 6"R S5 I SS N Z O O IL CD z 27-10 1/2" uj — � 6"R I r 1 16 R 24'-10 1/2" f COLUMN PLAN LEGEND o ❑ -3-2x6 LAMINATED COLUMN LOCATION r� z 20'-10 1/2" — �- 6"R I w e -3068 PLAIN, FLAT SLAB FIBERSTEEL WALKDOOR " J Fil W/LEVER LOCKSET, SINGLE CYLINDER DEADBOLT, rr ^^ b g g 1 & CLOSER v J 16"R 16'-10 1/2" S4 S4 - (3) 4429 VINYL SLIDING HAYFIELD WINDOWS W =  A- (2) 14'xl 4' INSULATED OVERHEAD DOORS W/7"x7"JAMB •..J ==_LJ_I 13'-10 1/2" — 6 R C C �-81 M BASE ANCHORS ORS & OPERATORS SS I S5 - 7/16" OSB SHEARWALL SEE PAGE S5 OF S6 FOR U =_ i ( Q � O I Qi DETAILS) -30N30"ATTIC ACCESS (VERIFY LOCATION) Q - - ALL STEEL FASTENED W/STAINLESS STEEL SCREWS r 1 �'-_ 6'-to 1/2" — T6"R o 16"W- 16" DIAMETER FOOTING W/ �J A MIX (5)50# BAGS OF SACKRETE WITH 2-1/2 �_ S4 iv GALLONS OF WATER. PLACE CONCRETE BELOW 1 0 24"R 24"R 24"R 24"R 24"R 24"R 24"R 16"R 2'-10 1/2" AND ABOVE BOTTOM OF LOWER COLUMN IN ;o I I I I I I I 16rW ONE OPERATION. USE 218M STILT. (CONCRETE ►►� l l l 1 "W Z 0'-0" -- 0'-0" MINIMUM COMPRESSIVE STRENGTH = 2500 PSI) ..,,� �— O — 16"R- 16" DIAMETER FOOTING W/ 8"THICK MINIMUM READ]-MIX CONCRETE > = O BELOW BOTTOM OF LOWER COLUMN WITH ! 1 � S4 ADDITIONAL READI-MIX TO 70P OF 218M STILF (9"±). PLACE CONCRETE BELOW AND ABOVE BOTTOM 01- 7-4 1/2" 7-6" 7-6" 7-6" 7'-6" _ 7-6" 7'-6" 7-4 1/2" LOWER COLUMN IN ONE OPERATION. X 24"R-24" DIAMETER FOOTING W/ O 10"THICK MINIMUM READI-MIX CONCRETE 0° BELOW BOTTOM OF LOWER COLUMN WITH z O o cv N N N N 2v ADDITIONAL READI-MIX TO TOP OF 224M STILT (9"±). d 011 PLACE CONCRETE BELOW AND ABOVE BOTTOM b N oll OF LOWER COLUMN IN ONE OPERATION. C/'7 Z N N cl) J 2 Lo L1 Qw COLUMN PLAN � 8 ROUGH OPENING SCHEDULE UNIT SYMBOL WIDTH HEIGHT FROM LEGEND Di 38 1/4" 811, A 52 1/4" 33 5/8" DRAWN BY.- RAMEY DATE.' 1 1/7/05 CHECKED 8Y.' C. BYRD DATE.' 1 1/23/05 REVISED DA TE• REVISED DA TE. REVISED DA TE' REVISED DATE: MA �e�•pF �a Ew y . . All co • d' ,O t ?. 1 � SCALE:AS NOTED 2 8' c SHEET NO SCALE: MP I 1' 4' 16' J 1 OF S 6 OFFICE.• CUTCHOGUE, NY JOB NO, 128-0765 TRUSS / BRACING PLAN LEGEND 2 - 42' LL S.C. TRUSSES @ 7'-6" O.C.TYPICAL (2) 20d R.S. NAILS IN OVERHANG FRAME �\ V - 2x6 DIAGONAL END BRACES APPROXIMATELY 10 7-0 O.C. TYPICAL 'I o 0 - CONTINUOUS 2x4 LOWER CHORD TRUSS TIES 2x4 BEV. PURLIN APPROXIMATELY 3'-6" O.C.TYPICAL TOE NAIL OVERHANG RAFTER 10 TO OVERHANG NAILER WITH 0— C� 01 (1) 16d R.S. NAIL EACH SIDE 0 o A — -- -- L7 w S2 --- 7-7-- OVERHANG FRAME END TRUSS I� w B 2x6 OVERHANG NAILER Z O S2 ::::::::.:::: : :::: :::: :::::: :: :::: ,::: :: ::: . ,: :::: ::.. ........ ..::- O O _ s I (7) 20d R.S. NAILS o= END TRUSS W 3-2x6 CORNER COLUMN Z 0, V— ...... .. ..... ..... .... .... .. •_ _____ - -�-� '0 I O '`a W ...... ...., , 2 = I DETAIL #A — -_ y ,,,,,, :,,,,, ,,,, : I I I SCALE: 1 1/2„ - 1'-0„ ,,,,,,, . .. :: . . . .. .. : : . .. . I ' I I PLANINIPIG BOARD 6-20d R.S. NAILS TOWN OF SOUTH OLD PER CONNECTION =0 U -O a O I DATE 0, ...... 2-2x6 END COLUMN EXTENSION12 .Q :0 a DETAIL # B '-- ...... I SCALE: 1 1/2" - 1' 0" o �s 2x4 PURLIN R I/. � � TRUSS / BRACING PLAN Z U 60d R.S. NAIL 60d R.S. NAIL X u zco II„ 20 GA. GALVANIZED T � O I ) PURLIN CONNECTOR ! n a R I/2 TOP TRUSS CHORD z ©OUSP R74 HURRICANE ANCHOR \ lJW = FASTENED TO TRUSS AND PURLIN o• �� Q N W/ 4 0.131"x 1 1/2" R.S. NAILS •'i • IL w 20 GA. GALVANIZED® / 4 U vi TRUSS \ PURLIN CONNECTOR (1) #9xl"TRU-GRIP SCREW ON PEAK SIDE AND i l l S o, (2) #9xl"TRU-GRIP SCREWS ON EAVE SIDE OF _J 10x15 PL. • .o °°°°° °° 6'-10 1/4" PURLIN IN HOLES SHOWN (JOINT MUST BE TIGHT \ BEFORE FASTENING CLIPS) 0 o e o0000 oo 13-8 1/2 • 00 p 0000° oo o (1) #9x1"TRU-GRIP SCREW ON PEAK SIDE AND o °oo° o°o (2) #9xl"TRU-GRIP SCREWS ON EAVE SIDE OF °�oa� 2x4 BUTTED PURLIN DETAIL PURLIN IN HOLES SHOWN (JOINT MUST BE TIGHT C #J BEFORE FASTENING CLIPS �s 2x4 PURLIN DRAWN BY: RAMEY 2x4 BUTTED PURLIN DETAIL DATE: 1 1/7/05 ° °°° 11x15 PL. °°o° CHECKED BY: C. BYRD o WEB #1 DATE.' 1 1/23/05 TC' #? TRUSS DESIGN SPECIFICATION: 8'-3" 2x4 WEB REVISED DATE.' Truss has been designed by computer using the Purdue STIFFENER 12 REVISED DATE: Plane Structure Analyzer IAW current standards and o0 3x5 PL. �4 REVISED DATE. specifications of recognized engineering principles. WEB #2 WEB #3 ' 9 PL Trusses are manufactured by Morton Buildings, Inc. ?k70 1 PL. 18 GA. REVISED DATE.• LUMBER SPECIFICATION (2001 NDS for Wood Construction): WEB #4 13x8 PL. 18 GA. Lower Chord -- 1950f- 1.5E MSR Southern Pine 0 ®,` v Top Chord --- 1950f- 1.5E MSR Southern Pine 16x10 PL. 13x8 PL. 15x5 PL. �� Top Chord --- No. 1 K.D. - 19 Southern Pine H.B °�°°°°° °° °00 00 0000000 000 0 00000o 5 •• 18 GA. 4X5 PL. 18 GA. ° o;o °°° 1 lxl 1 PL. 18 GA. °0 0 9x9 PL. o°°°°°°°° °°° °°°oozo 4X5 PL. 4X5 PL. ° ° °°0000 ,,o �c .p Web Members -- No. 1 K.D. - 19 Southern Pine I.N. °° '° °° ooe0O0° 000 0 ,000000 00000°°° °°°° 15 1/2" 00 00000 000�0000 Oo 00000000000 O ° Ooo OOoOo 4— - 0000 000000 000°°° Oo °400 000 2x4 000 °0000°° •VVV • 000000 000000 0000°°°°°° oou0 OOo 000o__000 - 4X5 PL. °0000000° °00 00 Oo00 0 0 000000 000000 000 0000°°000 000,0000 0 000 000 2x6 °° OOOOOOp • TRUSS PLATE SPECIFICATION (ICBO Evaluation report No. 2929): ooeoo0 °°° 4X5 PL. LOWER CHORD • 00000 000000 00 00000o J ASTM A-653, Grade A 20 Ga. and 18 Ga.where noted, Orton truss plates identified by a � "Wr J galvanized steel M p 1 hexagon stamped every 1 1/4" along the center of the plate. 5-0 1/4" CAMBER A7 � I , �- � �• v� RAFTER LENGTH 22'-0 1/16" CENTERLINE = 1 1/4" 12'-2 13/16" Webs are 2x4's TRUSS SPACING 7'-6" O.C. LIVE LOAD 36 PSF 20'-10 1/2" DEAD LOAD 4 PSF SCALE.-AS NOTED CEILING LOAD 2 PSF 42' LL S.C. TRUSS SHEET NO. : 1/2"= 1'-0" L SCALE: 2' 8' TOTAL LOAD 42 PSF SCALE S 2 OF S 6 1' 4' 16' OFFICE: CUTCHOGUE, NY -7 JOB NO. ® FF2000 HI-RIB STEEL 128-0765 Qs 2x4 PURLINS @ 24"O.C. (NO. 2 SPF) PURLINFF2000 HI-RIB STEEL INSULATION STOP/ GABLE GABLE FLASHING 2x4 PURLINS @ 24"O.C.(S 16 (4) 2 1/4" R.W. OR 16d R.S. NAILS AIR DEFLECTOR T#16 GABLE TRIM (NO. 2 SPF) 2x4 BEV. PURLIN 2x6 FASCIA o U FILLER STRIP 7#194 TRIM USP RT4 HURRICANE ~'— (1) 20d R.S. NAIL THROUGH STRAP N 2x6 BEV. FASCIA o RT4 HURRICANE ANCHOR©QQ of I i & INTO BRACE 19 ® SOFFIT ANCHOR © Q 5" O.G. GUTTERS �� 2' END BRACE STRAP W/ PRE-PUNCHED Q_ M T#144 & 146 FASCIA TRIM 42' LL S.C.TRUSS® HI-RIB/SOFIFIT CAP TRIM i / HOLES (BEND TO FIT) FASTENED W/ m 19�o SOFFIT �• '' (3) 1 1/2" R.S. NAILS — R-19 INSULATION ON 4'2' END TRUSS i O Z HI-RIB/SOFFIT CAP 4 MIL VAPOR RETARDER 2x6 DIAGONAL BRACING FASTENED w 2x6 OVERHANG NAILER INTERIOR HI-RIB STEEL 2-2x6 E.C.E. i i '� TO COLUMN W/(4) 1 bd R.S. NAILS ZO 2x4 TOP BLOCK &T#1 1 42' LL S.C. TRUSS a:(2) 1/2 x5 1/2" M. BOLTS & 18 KYNAR HI-RIB STEEL n' (8) 20d R.S. NAILS 2x4 TRUSS TIE FIBERGLASS INSULATION UTILIZED — — ui AS FIRE BLOCK AS ALLOWED IN ADDL. 2x6 NAILER — — — — — — — — — — — — — — — — - r 1 IBC SECTION 716.2.1 - v 3-2x6 LAMINATED COLUMN � A � r) r LAJ INTERIOR HI-RIB STEEL KYNAR HI-RIB STEEL INTERIOR HI-RIB STEEL 2x4 L-NAILER W/T#136 &T#I I ; � (�� y 2x4 STRIPPING @ 32"O.C. � � `•� >- (4) ROWS 2x4 NAILERS(9 (2100f MSR SPF) 16'-0" U GRADE TO HEEL T#167 TRANSITION TRIM 2x4 STRIPPING @ 24" O.C. TO 8'-0" 3-2x6 LAMINATED COLUMN12 1 1/4"xl 1/4"xl4 GA. SUPPORT ANGLE F- 6 BLANKET INSULATION W/ FASTENED TO COLUMN AT EACH �-/ 4 MIL VAPOR RETARDER TRUSS IN CO)LUMN 3/4" PLYWOOD SADDLE CORNER WITH (3) .148"0 x 2" "'J �-�—� 2 STAINLESS NAILS. (12 TOTAL NAILS O LAMINATED COLUMN PER COLUMN) w 2x2 VERTICAL BLOCKING 14 GA. CHANNEL WITH 1/4" PLATED = O AT COLUMN LOCATION RIVET TO SUPPORT ANGLE U T#167 TRANSITION TRIM I - UNDISTURBED SOIL a-000 2x6 NOTCHED NAILER 1 X ©KYNAR HI-RIB STEEL WAINSCOT O STILT NOTES Z °° 1. INSTALL PRESSURE TREATED ( O 7/16" OSB PROTECTIVE LINER 13 �.J LOWER COLUMN WITH STILT IN T#167 BASE TRIM W/L-CAP TRIM PROTECTOR THE AUGURED HOLE. Z (1) ROW 2x8 TREATED SPLASHBOARD 11 a 4.a Lu = 2x4 NON-TREATED BASEBOARD 2. POUR MINIMUM THICKNESS OF Q � READI-MIX CONCRETE INTO THEUJI 1 1/2"xl" BLOCK &T#109 BASE TRIM HOLE AS SPECIFIED. Q vi 18" LOWEST 6"CONCRETE FLOOR 4' WIDE R-1 1 PERIMETER INSULATION* 3. BACKFILL AND COMPACT THE Lu S MEMBER CUT-OFF _J ANNULAR SPACE AROUND THE 81 M BASE ANCHOR to STILT ISOMETRIC COLUMN TO GRADE WITH SOIL a T AUGURED FROM THE SITE. FINISH GRADE ° •`' ' 4" MINIMUM COMPACTED GRANULAR BASE* 2x6 TREATED BOTTOM PLATE CONCRETE FLOOR NOTES 1.)3500 PSI,5 1/2 BAG MIX CONCRETE. 2.)REINFORCING:6x6-10xl 0 WWM. 4'_0" 3.)SLOPE GRADE AWAY FROM BUILDING @ 1"PER FOOT FOR A MINIMUM DISTANCE OF 10'PLUS DRAWN BY.' RAMEY OVERHANG WIDTH. 4.)WHEN A VAPOR RETARDER IS PROVIDED,PLACE A - DATE. 11/7/05 MINIMUM 6 MIL POLYETHYLENE VAPOR RETARDER ON TOP OF A MINIMUM 4"COMPACTED GRANULAR BASE AND DIRECTLY BELOW THE CONCRETE FLOOR. �` ; ,,Q a 81 M BASE ANCHOR Q CHECKED BY. R ` 224M (14 GA.) COLUMN STILT QQ T DATE., 11/23/05 =_ - 3 10 THICK MINIMUM READI-MIX CONCRETE ° d BELOW BOTTOM OF LOWER COLUMN WITH FINISH GRADE REVISED DATE: ADDITIONAL READI-MIX TO TOP OF 224M STILT (9"±). -- REVISED DATE.' NOTE: PLACE CONCRETE BELOW AND ABOVE BOTTOM NOTE: REVISED DATE; FOOTINGS ARE DESIGNED FOR A 24"O OF LOWER COLUMN IN ONE OPERATION. THIS SECTION IS THE SAME AS 2000 PSF SOIL BEARING CAPACITY. SECTION "A" EXCEPT FOR REVISED LOCAL CONDITIONS MAY REQUIRE THE ITEMS AS NOTED. MODIFICATIONS. i�w1►, q; S I D EWALL SECTION A 218M (14 GA.) COLUMN STILT Q •, �O �.0• SCALE: 1/2"= 1'-0" e: 8"THICK MINIMUM READI-MIX CONCRETE •o z BELOW BOTTOM OF LOWER COLUMN WITH ADDITIONAL READ] TO TOP OF 218M STILT (9"±). • 4b M OF PLACE CONCRETE BELOW AND ABOVE BOTTOM I • 16"O LOWER COLUMN IN ONE OPERATION. , a r� �� ��► NOTE: l + IDENTIFIES THAT ARE NOT BYMORTONI BUILDINGS, INC. ORMO TIOND ENDWALL SECTION B BUILDINGS' SUBCONTRACTORS AND ARE THE SCALE: 1/2"= l'-0" OWNER'S RESPONSIBILITY. S E.•AS NOTED SHEET NO. S4 of S6 OFFICE.' 4.2' WIDE CUTCHOGUE, NY (ZONE 2 & 3) JOB NO. �--------------_. 128-0765 APPROVED ter PLANNING BOARt TOWN OF SOUTHOLb 2x4 PURLINS @ 20"O.C. o DATE co So RT4 HURRICANE ANCHORS I �— ol 2x6 UPRIGHT 2x4 TOP BLOCK &T#1 1/136 2xl0 HEADER TRUSS TOP CHORD I a_ FLAT STEEL w m 2x6 NAILER O Z 2x6 BLOCK 2xl2 HEADER 4.2' WIDE (� Z T#124 T#15 NOTE: (ZONE 2 & 3) V � T#129 O.H.D. RT. CLIPS TO BE USED ON FIRST ROW o, OF PURLINS FROM SIDEWALL, FIRST 2x2 BLOCK T ALUMASEAL THREE ROWS FROM PEAK, AND AT PURLIN TO END TRUSS. `� z T#151 T#152 T#154 — T#105 42' PURLIN LAYOUT U 2x3 JAMB (BEYOND; GRADEITO BOTTOM SCALE: 1/2"= V-0" `�-� I l 1 LLJ BOTTOM 2' TREATED) (3) 2x6 JAMB COLUMN (BEYOND) OF 2x6 BLOCK r ^ z 2x6 TRACK BLOCK (BEYOND; BOTTOM 2' TREATED) O ' ' 1 _ _ I W =9 _ OHD HEADER SECTION C �2 -_— SCALE: 1" = V-0" 2x4 TRUSS TIE II U 60d R.S. NAIL 20 ga. GALVANIZED LOWER TRUSS CHORD o PURLIN CONNECTOR E— LOWER CHORD OF \ J 7/16" OSB END TRUSS \ o, °o w Z 0o O STD. 2x4 BUILDING o O ' - - - - - - - - - - - - - - - - -- ( 1 NAILERS @ 24" O.C. --- -- - -,— _ - -'— _ _ —'— _ - ( �./ — — — — — (1) #9x1"TRU-GRIP SCREWS ON PEAK SIDE AND X 2x6 VERTICAL BLOCKS @ (2) ON EAVE SIDE OF PURLIN IN HOLES SHOWN. O COLUMN BETWEEN NAILERS (JOINT MUST BE TIGHT BEFORE FASTENING CLIPS) Zo ' = = — - - - - - - - - - - - — — ADDITIONAL 2x6 NAILER 2x4 TRUSS TIE DETAIL z PERIMETER OF OSB SHEETS uJ - -_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ NAILED W/1-3/4"SHINGLE 20d R.S. NAIL THROUGH CL w GUN NAILS SPACED 3"O.C.Q STRAP INTO TIE Q vi (3) 11 1/2" R.S. NAILS ' 2' LONG END BRACE STRAP UJ 8 ' - - - - - - - - - - - - - - - - - - ' THROUGH STRAP — — — — — OSB NAILED TO INTERMEDIATE i j` (4) 2 1/4" R.W. NAILS —J SUPPORTS W/1-3/4"SHINGLE Q GUN NAILS SPACED 6"O.C.® DRAWN BY.' RAMEY — — — — — — — — — — — — — — — — — LAMINATED COLUMN 2x4 TRUSS TIE DATE.' 1 1/7/05 — — — — — — — — — — — — — — — — — — CHECKED BY: C. BYRD DATE.' 1 1/23/05 2x4 TRUSS TIE TO ENDWALL DETAIL - - - - - - - - - - - - - - - - - - REVISED DATE . . . . . . . . . . . . . . . — — — — — — — — — — — — — — 5/4x6 NAILER REVISED DATE.' REVISED DATE - - - - - - - - - - - - - -. - - _ REVISED DATE.' — — — — — — — — — — — — — — — — — — 2x8 TREATED BASEBOARD 2x6 BLOCK BETWEEN NAILERS NAILED TO COLUMN W/20d ,.ollin" ►w GUN NAILS, NAILED 3"O.C.0 - - - - - - - - - - - - - - - - - - 2x4 NAILERS co !✓�, 7/16" OSB LAMINATED COLUMN OSB SHEARWALL DETAIL LAMINATED COLUMN SCALE: 1/2" = V-0" OSB SHEARWALL ELEVATION 0 SCALE: 1/2" = l'-0" SCALE.'AS NOTED SHEET NO. S5 OF S6 OFFICE: CUTCHOGUE, NY JOB N . 128-0765 ROOF STRUCTURE FASTENING SCHEDULE D VENT-A-RIDGE TO RIDGE BASE TRIM #9 x I"STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS @ 8"o.c. ' ` � RIDGE BASE TRIM TO 2x4 PURLINS #9 x 2"STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS AT EVERY HI-RIB (1'-0"o.c.) �_ c-RIB STEEL TO 2x4 PURLINS #9 x 2"STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS AT EVERY HI-RIB (1'-0"o.c.) o ® 20 ga. GALVANIZED PURLIN CONNECTORS #9 x 1"TRU-GRIP SCREWS °` �s 2x4 PURLINS TO TRUSS ` 0.200"x 6" (60d) RING SHANK NAILS IN PRE-DRILLED HOLE APPROVED Y C1_ © RT4 HURRICANE ANCHOR TO 2x4 PURLINS (4) 0.135 (8d) x 1-1/2" RING SHANK NAILS co �i RT4 HURRICANE ANCHOR TO TRUSS (4) 0.135 (8d) x 1-1/2" RING SHANK NAILS PLANNING BOARD O D ® Lu Z 42' LL STRAIGHT CHORD TRUSS TO COLUMN (2) 1/2"x5 i/2"MACHINE BOLTS f �U��" � (8) 0.177"x 4" (20d) RING SHANK NAILS �e y Z O 11 , J W` WALL FRAMING FASTENING SCHEDULE Q z COLUMN STILT (14 GA.) TO COLUMN (12) 0.148"x 2" (6d) STAINLESS STEEL RING SHANK NAILS I �Lj nj i 81 M BASE ANCHOR TO COLUMN 0.177"x 2-1/2"STAINLESS STEEL NAILS (4) PER ANCHOR Z`''�• -- a >> 2x8 SPLASHBOARD TO COLUMN (4) 0.177"x 4" (20d) STAINLESS STEEL RING SHANK NAILS @SPL UICE/ (3) 0.177"x 4" (20d) RING SHANK NAILS @STANDARD CONNECTION � 2x6 NOTCHED NAILER TO COLUMN (4) 0.148"x 3-1/2" (16d) NAILS @ SPLICE/ (3) 0.148"x 3-1/2" (1 6d) NAILS @ STANDARD CONNECTION � 7/16" OSB TO SPLASHBOARD 8, NOTCHED NAILER 0.099"x 1-1/4"ASBESTOS SIDING NAILS Q (9 2x4 NAILER TO COLUMN (4) 0.148"x 3-1/2" (1 bd) RING SHANK NAILS @SPLICE/ (3) 0.148"x 3-1/2" (1 bd) RING SHANK NAILS @STANDARD CONNECTION �- Q END TRUSS TO 2-2x6 END COLUMN EXTENSIONS \(6) 0.177"x 4" (20d) RING SHANK NAILS 9 2x4 PURLIN TO END TRUSS 0.200"x 6" (60d) RING SHANK NAILS IN PRE-DRILLED HOLE RT4 HURRICANE ANCHOR TO END TRUSS (4) 0.135" (8d) x 1-1/2" RING SHANK NAILS v_ .j is HI-RIB STEEL TO NAILERS #9 x 2"STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL.DRIVE SCREWS AT EVERY HI-RIB (1'-0"o.c.) O i9 SOFFIT TO WALL INSERTED IN PRE-FORMED SLOT IN SOFFIT/HI-RIB CAP � SOFFIT TO FASCIA T-50 MONEL STAPLES (2) PER PIECE O � � Qi 7/16" OSB SHEARWALL - T u o OSB TO PERIMETER BLOCKS/ FRAMING 0.120"x 1-3/4"SMOOTH SHANK SHINGLE GUN NAILS @ 3"o.c., LL_ Q ® OSB TO INTERMEDIATE FRAMING 0.120"x 1-3/4"SMOOTH SHANK SHINGLE GUN NAILS @ 6"o.c. x BLOCKS TO COLUMNS 0.131"x 3-3/4" (20d) SMOOTH SHANK GUN NAILS @ 3"o.c. O Z m O CD LL.I i N w W o- N #8x3 1/2" WOOD SCREWS FASTENED THROUGH THE WINDOW JAMB g FLASHINGS INTO THE 2"x4" ROUGH FRAMING. PRE-DRILL HOLES 10" 1 1 1 O.C. IN WINDOW JAMB FLASHINGS TO ACCEPT WOOD SCREWS. SCREWS ARE NOT REQUIRED IN THE HEAD OR THE SILL. �jJ' O.S.B. SHEATHING IS 1"WIDER THAN THE WIDTH OF THE WINDOW FROM OUTSIDE OF TRIM TO OUTSIDE OF TRIM. O.S.B. SHEATHING IS 1"TALLER THAN THE HEIGHT OF THE WINDOW FROM OUTSIDE OF TRIM TO OUTSIDE OF TRIM. DRAWN BY.• RAMEY DATE: 1117105 CHECKED BY.• C. BYRD HEIGHT HEAD FLASHING DATE. 1 1/23/05 OF WINDOW : 7/16"OSB PANEL REVISED DATE., 7/16"OSB PANEL REVISED DATE.• #8 x 3 1/2" WOOD FINNED WINDOW REVISED DATE. FINNED WINDOW SCREWS @ 10" O.C. REVISED DATE.' SILL FLASHING --- WIDTH WINDOW JAMB FLASHING — , OF WINDOW ��� NE 2"x4" ROUGH FRAMING ��,�k- . •y+1„ �g- FIN WINDOW SECTION © G * ` FIN WINDOW JAMB DETAIL •o • I • • WINDBOURNE DEBRIS PROTECTION - FIN TYPE WINDOW SCALE:AS NOTED SHEET NO. S6 OF S6