Loading...
HomeMy WebLinkAbout33059-z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-32726 Date: 11/15/07 THIS CERTIFIES that the building EMERGENCY FIRE REPAIR Location of Property: 55575 MAIN RD SOUTHOLD (HOUSE NO.) (STREET) (HAMLET) County Tax Map No. 473889 Section 62 Block 1 Lot 15 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated MAY 15, 2007 pursuant to which Building Permit No. 33059-Z dated MAY 22, 2007 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is FIRE REPAIR TO AN EXISTING BUSINESS BUILDING AS APPLIED FOR. The certificate is issued to PASQUALE T RUTIGLIANO (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A ELECTRICAL CERTIFICATE NO. 3045111 11/08/07 PLUMBERS CERTIFICATION DATED 11/08/07 CHARLES AZZAR Aut oriz 'd Signature Rev. 1/81 ' Form No. 6 TOWN OF SOUTHOLD 114 BUILDING DEPARTMENT TOWN HALL Eel •_;. n"i'i. TOWf.'SiF Sr THOi_7 r 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural Or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a.certificate of Code Compliance from architect o'r engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, oi-buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied; the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$25.00,Additions to dwelling$25.00, Alterations to dwelling$25.00, Swimming pool $25.00, Accessory building$25.00, Additions to accessory building$25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy- Residential$15.00, Commercial$15.00 Date. New Construction: Old or Pre-existing Building: (check one) Location of Property: /Y)A3 w House No. Street ?? Hamlet ?�Owner or Owners of Property: C d`L I G,!'► a Suffolk County Tax Map No 1000, Section (p„? Block Lot Subdivision Filed Map. Lot: Permit No. "5o 0 Date of Permit._ 7.7 P37� Applicant: Health Dept. Approval: Underwriters Approval: Planning Board Approval: / Request for: Temporary Certificate Final Certificate: L' (check one) Fee Submitted: $ Applicant Signature Go -Z3JJ7 '2& FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 33059 Z Date MAY 22 , 2007 Permission is hereby granted to : PASQUALE T RUTIGLIANO PO BOX 1339 SOUTHOLD,NY 11971 for EMERGENCY FIRE REPAIR TO AN EXISTING BUSINESS BUILDING AS APPLIED FOR. PLANS AND CERTIFICATIONS TO FOLLOW. at premises located at 55575 MAIN RD SOUTHOLD County Tax Map No. 473889 Section 062 Block 0001 Lot No. 015 pursuant to application dated MAY 15, 2007 and approved by the Building Inspector to expire on NOVEMBER 22 , 2008 . Fee $ 250 . 00 A ized Sig ture Rev. 5/8/02 cl�[J�[J�[J�[.([1GfrJ�GI�[.1�[J�[nrJ�[J�C1�[1[J'C nC PL1GlC1[J'[15[.n[J [1a�[J'[Jo![1[.l M[J�[J[1[1'[.nrJ�[.tGfGI[J�[1�[J�rJ�[J�[J�[nL3rL3f rL3r[J�rJr 5 BY THIS CERTIFICATE OF COMPLIANCE THE 5 5 NEW YORK BOARD OF FIRE' UNDERWRITERS S 5 S S BUREAU OF ELECTRICITY 5 5 40 FULTON STREET — NEW YORK, NY 10038 c� 5 CERTIFIES THAT 5 5 5 5 Upon the application of upon premises owned by 5 5 5 ABCO ELECTRIC CORP SOUTHOLD WAYSIDE MARKET 5 5 1361 II COLN AVE SUITE 14 SOUTHOLD, NY 11971 5 5 HOLBROOK, NY 11742, c5 SLocated at 55575 MAIN RD SOUTHOLD, NY 11971 5 S5 5 Application Number: 3045111 Certificate Number: 3045111 5 5 5 5 Section: Block: Lot: Building Permit: 33059 BDC: ns11 5 5 5 5 Described as a Commercial occupancy, wherein the premises electrical system consisting of 5 electrical devices and wiring, described below, located in/on the premises at: 5 S 5 5 First Floor, 5 5 5 A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed 5 herein, was conducted in accordance with the requirements of the applicable code and/or standard 5 promulgated by the State of New York, Department of State Code Enforcement and Administration, or other 5 5 authority having jurisdiction, and found to be in compliance therewith on the gth Day of November,2007. 5 5 Name QTY Rate Rating Circuit Type LC Alarm and Emergency Equipment 5 5 Combo Exit and Emergency Light 2 0 S 5 Appliances and Accessories 5 Exhaust Fan 2 0 F.H.P. S L'SJ Furnace 1 0 Oil 5 Show Case 2 0 S Wiring and Devices 5 5 Fixture 6 0 Incandescent 5 5 Fixture 21 0 Flourescent C, 5 Outlet 29 0 General Purpose 5 SReceptacle 11 0 General Purpose 55 5 Switch 22 0 General Purpose 5 SReceptacle 2 0 3p-20a Special 5 SReceptacle 6 0 1p-20a Special 5 5 5 5 seal 5 5 . 5 5 5 1 of 1 S 5 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated-,- S �°1WLPLrL3PEFC. J15cPr.PrJMrJ�cPrJ6U�cTcftPcPrJ�rJ�C.fc.frJrJ�rJ�rJ�rnC.fr�r.PC I�cPc.fCJ�L3rL3 r I[C11r�cJ�cfrJ�C.fC.rC.I��.fr�J�c.I�rJC.(rJ�r.�'r�nrJrJ�rJ�c�PC PrJ� O° o��gl1FF0(�.c o y 2 Town Hall,53095 Main Road p • �� P.O..Box 1179 y�0 Fax(631)765-9502 Southold, New York 11971-0959 .( �� Telephone(631)765-1802 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATION Date: ��• �- Building Permit No. j3 SJ 9 Owner: �i45' �-J�- 'Q < < (Please p t) Plumber: ��al (-eS A-Z:ze"-z (Please print) lead. I certify that the solder used in the water supply system contains less than 2/10 of 1% (Plu ers Signature) Sworn to before.me this day of ND U�04 be V, 20 0 7 Notary Public, M( County PENNY BEDELI. Notary Publir. State of New York Nc, ' '�'--,9993I. _ Qualifies 'i0'folk County Commission Expires Sept.29, / OF SOpryolo VVAqSv �y00UNTY,N73 TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: PLA DATE � �� INSPE CTOR-7 3 �OF SOUTH �o� oho o�ycOUlm,� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INS ATION [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RES r T CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ISLj 0 REM KS: IZ DATE f - INSPECTOR-,,"L? TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] RO GH PLBG. [ ] FOUNDATION 2ND [ NSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS. r 9659, /0 t DATE INSPECTOR oF so�lyolo 3 3 s� courm,N�' TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST p�ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ FRAMING STRAPPING [ ] FINAL [/ \] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION s REMARKS: IA� � 6 DATE INSPECTOR FIELD INSPECTION REPORT 7DATE I COMMENTS uj ,b FOUNDATION(1ST) (J� ------------------------------------- \f FOUNDATION(2ND) b z _ d CA U� J ROUGH FRAMING& y PLUMBING vI INSULATION PER N.Y. STATE ENERGY CODE U FINAL ADDITIONAL COMMENTS � 0 07 Z taao,� Az 9,L2q07 I07 i Q/ 0 0 1 � y x d y 8.. ■■MEN■■ ■MS■■N■I■■■■■■■■■■■■EMMM ■■■■■■■�■ ■■G�■■■■■■■■■■■■■■■ ■■■■■■■ ■ ■■`1�i1i ■■■■■■■■■■■■■ ■■■■■■■ ■A■■■■®■■■■■■■■■■■■■ MEN ME ■ ■■■■■■f■■■®■■■■■■■■ ■■■■■■■ ■[ i■■■■■■■■■■■■■■■ ■■■■■■■ ■■■■O■■■M■■■■■■■■■■ ■■■■■■■ ■■M■N■■■■■M■■■■■■■■ zasement •• �Ext. Walls ��,�wplace 1-6 0 o _ _ _ �� TOWN OF SOUTHOLD - PROPERTY RECORD CARD OWNER STREET „ j VILLAGE DIST. SUB. LOT FORMER OWN Rid hn c'Sao O r✓ N - E ACR. Wry 1 {-er Adc M' sp,-) S j( W TYPE OF BUILDING RES. SEAS. VL. FARM COMM. CB. MISS Mkt. Value �r LAND IMP. TOTAL DATE REMARKS 66 2 2Z &y aa 'I ell _/ fir I ,,,,�,, / AGE BUILDING CONDITION NEW NORMAL BELOW ABOVE FARM Acre Value Per Value Acre Tillable 1 Tillable 2 Tillable 3 Woodland Swampland FRONTAGE ON WATER Brushland FRONTAGE ON ROAD House Plot DEPTH b BULKHEAD Total DOCK TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL -, Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey www. northfork.net/Southold/ PERMIT NO. 3!)02-E Check er , ()'D Septic Form N.Y.S.D.E.C. Trustees Examined 120 Contact: Approved 20 Mail to: Disapproved a/c Phone:1pa.J Expiration ,20 - � Building Inspector lY 15 W'' .-APPLICATION FOR BUILDING PERMIT - —---_ - - Date /tx. , 20 INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according-to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months.Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code, housing using code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. j J (Si ature of applicant or name,if a corporation) (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder Name of owner of premises` �Y�-� 1 R®� (As on the tax roll o� atest d ^� If applicant is a corporation, signature of duly authorized officer D _L nr g`�CPla�1��, NZ AT FED' gU1�DING P� FOR THE (Name and title of corporate officer) NOS g AM TO S'. '65-1ao? WSPECW�NREaD) Builders License No. AOo�NpP�10p CONCRETE M6�NG Plumbers License No. FOR POOR , P Electricians License No. 2 ROUGH - FR gosl Other Trade's License No. 1NSo_A�,ON slRkur ION 3 E . CON '.OR C O -SHE 4• F1N�OMp1.E�E sHA�-� gEE� NEW 1. Location of land on which proposed work will be done: BE SJRk\301 ON E CODES OF FOR CONMEN�s of RES4oNS18�aORs. House Number Street H STAT 'CONSSRUC SIGN OR , County Tax Map No. 1000 Section Block ''' -'Lot Subdivision Filed Map No. Lot (Name) _. 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy 3. Nature of work(check which applicable): New Building Addition Alteration Repair� Removal � Demolition Other Work (e a P(VA�1t�, $� (Descripti%n 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed.occupancy, specify nature and extent of each type of use. VDU—�) f r�- � 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front „§ RRear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO Will excess fill be removed from premises? YES NO 14. Names of Owner of premises Address Phone No. Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTY OF S j f F-14) PAY 910r., le, T (ZJ�r n $Af o being duly sworn, deposes and says that(s)he is the applicant (Nam of individual signing contract) above named, (S)He is the ® w►ti c-, (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief, and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this _ day of M A 20 0-1 r Notary Public U Signature of Applicant John M.Judge NOTARY PUBLIC,State of New York No.01JU6059400 Qualified In Suffolk County Commission Expires May 29,200 • IeR ` Rpe roChem II Model 160 460 460 600 600 [Potassium Carbonate] ( Volume OQ/0.�/07 max flow points generally 5 00-14 10-15 14-1914-2 MN flow pts with rangelwokffryer 5 8 2 .__....._.._...___.___...__—__ —_._..__. ._... MECHANICAL CONTROL rrax pipe volurre-rrpv 1500 3400 2600 4215 3465 1500 HEAD NMCHo3 between 1st/last nozzle 600 3000 2000 1688 1313 per side 600 SCALE 3/8"X12" I Mabmum Part Tip Row Nozzle;Equipment Type Coverage No. No. Pts. Per Cen Any Notes Hts Quan. 12" AUG 2 0 '7 nge 2x 8 551029 1H 1 x e 5 I f _ 12x28 551066 1L 1 x 22 inch from fronVrearedge 13-24 X I [ 28x28 551027 2L 2 x No Shelf', 34-48 TO REMOTE MANUAL 12" FUSEABLE LINK I Griddle 1080 si,36 Is 551026 1 L 1 Over any 12 in corner aim diag op 10-24 PULL STATION TO FUSIBLE LINKS 551029 1 H 1 24-48 TO GAS VALVE 2D `-- ( 1_440_si,4.81s 551027 2L 2 10-24 v 551 SHUT-OFF GREASE TIGHT SEAL 02 ( 1080 si,36 Is 551029 2L 1 0-6 inch of short side edge 13-24 0 551029 2H 1 24-48 Chem I Wok 24x6 deep 551026 1 L 1 x 13-24 1 H I 551029 1 H 1 x 24 48 {_..._...__...__._ __. __.24-30x8deep 551027 2L 2 x 13-24 551028 2H 2 x 2448 • TO DISCHARGE PIPING Fryer,Tilt Skillet 500 si,27.75 Is 551027 2L 2 x T.S.nozzles tow ards front openin 13-24 1 H S.2ftx4ft 551028 2H 2 x 2448 1 Gas/Hectric-Char 624 si,26 Is 551026 1 L 1 x 13-24 ---.._......_..__-----___—.------__—_--551029 1 H 1 x ! 2448 864 si,36 Is 551027 2L 2 x 13-36 ( 551028 2H 2 x Over any comer aim to center 3648 Lava Rock-Char 624 si,26 Is 551027 2L 1 x 15-24 160PLC 551027 2L 1 x 24-35 O O p Natural,Charcoal, 480 si,24 LS, 551026 1L 1 x 15-24 ll�s uite,Wood 6 inch d 551029 1H 1 x 24-35 PULL 78.00" Chain Broiler 1026 si,38 Is 551026 1L 1 Parallel to chain surf,diag opp 1-3 STATION ri hbSalamander 1064 si,36 Is 551026 1L 1 Parallel to grate surf,diag opp I Duct 100 in/P,34 Is 551038 2D 2 or 31.5 inch diam round duct 0-6 1 1 150 in/P,51 Is 551038 2-21D 4 or 47.5 inch diam round duct 0 1 Penum 10 ft x 4 ft [V] 551029 1 H 1 x 1/3 vert filter ht,6/max-Renum end 10 ft x 4 ft 551029 1 H 1 1 12 inch of back filter edge, 1 ElectroStatfcP-ecip j 551038 2D 2 1 nozz before&after each cell jAdditional Notes Components Part Nos Nbdel Check No Manifolds Rping Schedule 40 Nbchanical Control I-f ad 551200 NM x R1300&460-Split Rping and Straight Rping shall be pemritted. Nbchanical Control Had 1203 11,/I R GAS SHUTOFF VALVE I FCL 300,460,600-2 Row Vs used before/at Pange-Wok Fryer. Bech is Control Had- 1202 ECI-13-120 RL 600 Spl'It piping only, 1/2 inch pipe to 1st split I Bectric Control I-f ad- 51201 BD—&24 I I I I FCL 600-14 flow points max per side,no nozzle before 1st split. Enclosure[300/460 as 2nd] 0966 6NI-S =Maximum Row Points shall be used for all 1/4 inch pipe. Pneumatic ActuqCylindder4 PAC-10IMaximum elbow s in the system is 25 and 5 elbow s Tee to Nozzle. Fuseable Link K1,2 FLK1,1A(Maximum 10 ft rise allow ed[tank outlet to highest or low est nozzle] Fuseable Link F6 FLI-1 Rpe diameters can only re ducetowards the the final end points.Fuseable Links9 R_-360 ;Split enters Bull of fee hb piping Traps Fuseable Link7 FL-450 1_ . __.__._ _._.._____ _.___.___-___.. .___.._.__.__..____.___.__-. _._.I t�tectors inthe exhaust duct shall be centered&12 ft max into du Fuseable Link R_-500 Detector over each appliance,over 48"gets additional fvbchanical Rill 4 RPSM x:, I Ni7-B,ECJ-13&NMUCi-M3x 8 feet pneumatic tubing&3 cylinders. Comer Rilleys 415670,550982 SBR1,W PAG10 -M3ic 100 feet prieurretic tubing&10 cylinders Corner Pulleys 423250 CBP--1 ECkB-supervision req'd&1A battery backup&solenoid monitor. The Tee Pulley 0166 TR1 _;M3xirrum 20 detectors,150 feet cable,40 pulleys,per control head Bectrical Sv itch 551154,5,6,7 NIS-= Maximum GVSO,100 feet cable and 30 pulleys,per control head. Solenoid Nbnkor 550302/3 SNQ4/120 ;Tee Pulley allowed only for 2 GVSO-[314-1 1/2'],[2"],[21/2-3"]. Gas Shutoff Valves 3/4" 550593 GV-75 1 ;Tee Pulley not allowed for rrultiple link lines to single control head. Gas Shutoff Valves 1" 550594 GV-100 BV S*used with B�M:U or MD-q%HvX�[3 Control F-leads Gas Shutoff Valves 1 1/4" 550595 GV-125 Control Fbad may be installed on sin le c linders on 1 Gas Shutoff Valves 1 1/2" 550596 GV-150 Fryers to have Hgh Linit Control to shut off fuel at 425 degrees Gas Shutoff Valves 2" 551049 GV-200 Ivbnual Full&Fbrtable FFe Extinguishers located as follows Gas Shutoff Valves 21/2" 550185 GV-250 10-20 ft from hood,41/2-5 ft from floor and in the path of egresl Gas ShutOff Valves T 550186 GV-300 " On discharge:Supply damper closes-Gas shuts off in kitchen-Exhaust fan stays on-Bectric shuts off under hood-Fire alarm activates bk C:Excel/00-04/03-py41 rev 020104, PyrcChem 1Gtchen Knight ll, p/n PN551274(1)rev 411102 _.....-._..... -._..._.._.. -... ..__....__....._....._.........._......_..._...... ......................_................._...._-.............._.._- _..........._; gg nt i.4.p h•n,t� le Hood & Fire Protection Co. fim. 965 Wei Ave. Lindenhurst, N Y 11757 a _ PINNACLE 631/ 991 -8080 Fax: 631/ 991 8079 _ - EST. '1958 Job Name: Wayside Market 55575 Main Road Southold, NY 11971 Pasquale 631 / 521 -5456 08/01/07 - All Views to the following scale 1/4"=12" _Dimensions Scale 1/411=121� KITCHEN CONSTRUCTION[c] X New Kitchen Existing Kitchen _NON Combustible[Masonry] _Limited Combustible—[S/Rock-metal stud] _Combustible[S/Rock-wood studs] _FIRE RATED WALLS-2 hrs _Existing—1 hr ok Special Sprinkler Installation—1 hr ok ®FIRE RATED SHEET ROCK WITH S/S OR TILES r I. X OPENING PROTECTIVE[1 '/hr]-{Self closing,self latching,fire rated door assembly] Special Sprinkler Installation—3/hr ok ON WALLS WHERE HOOD IS MOUNTED OR OK WITHOUT O enin Protective if ALL of the following comply: DUCT INTAKE MUST BEA P 9 9MINIMUM OF 10'AWAY Draft Curtain 24"ht[NC/LC] Hds/Aes Special Sprinkler Installation FROM EXHAUST Exit at Grade—or—Sprinkler heads within 24 inches of draft curtain,60 inches apart, kitchen side r ex on wt x Cooking Equipment in the Kitchen _Cooking Equipment at the front counter _Cooking Equipment in the dining room C �� Min. _Cookin Equipment in a Mobile unit d Cookin Equipment in a Concession stand Pizza Oven d s/8°xxsneet rock 1s° ao°__ 9 [ l— 9 [dl_ [ ] I x i 18„ � Rid ed Co duit HOOD Roof Curb —Exhaust cfm—Medium Duty[d] X Exhaust cfm—Heavy Duty[d] _Exhaust cfm—Extra Heavy Duty[d] [hot top,griddle,fryers, pizza,rotisseries] [range,work,gastelec broilers] [Solid fuel char broilers] [Wall-Linear Ft x300],[S-island LinearFt x500] [Wall-LinearFt x400],[S-island LinearFt x6W] [Wall-LinearFt x550],[S-Island LinearFT x700] ------ - . ...... . .. --- electric panel to X Liquid tight external weld 12 ft max hood length per exhaust riser[d] X 18 ga steel or 20 ga Stainless be field I I bgged -------------'------------------ -- - X Supply Air 50/50 approx replacement[d]_Supply Air 10 deg difference except A/C[d] Supply air hood damper(286 deg max) _Clearance-3"to Combustibles, including 1 inch mineral wool, (insulate the combustible not the hood) ACCESS DOOR 0 A D DROP OILING XClearance-T to Limited Combustibles[d] _Clearance-0"to Non Combustible[d] _Insulation max Flame Spread Rating25/x X CHARBROILERS—4' min to hood Solid fuel to have spark arrestors[d] Solid fuel—under separate hood 16" X FRYER—16 inch space to flame producing appliance or 16 inch high steel baffle 3"AIR SPACE 173.00" X FILTERS to heat source 18"minimum To flue baffles 6 inch minimum(uprights, roticerees, ovens, etc) 6 e X6 inch overhang all sides X 7 ft maximum off floor X 24 inch minimum height all sides ! 54.09' _LISTEN HOOD installed in accordance with terms of its listing. X Elec.Wire in conduit or EMT 16"HIGHS/S _Manufacturer _Exhaust cf n _Clearance(Hood bottom to appl top) NO SHELF I BAFFLE _Model# _Supply cfm _Maximum cooking surface temp Max DUCTS 00 00 00 00 0 X AIRFLOW 1500 ft/minute minimum �I � a mmmmmmm ,.••®o. •,..®o. .•�o. .•.�v. X Dimensions(17"x17") x 16 ga steel or 18 ga Stainless X Field welds to be Bell or Telescoping[d] o Duct exits bldg directly as possible[d] Horizontal duct travel less than 75'[d] _Duct connections have flush bottoms[d] X Liquid tight external weld X No exhaust dampers used X Duct pitched back hood to collect grease X Ducts not shared by other systems Shall not pass thru firewalls _Not insulated until inspected CLEARANCE-T minimum to combustibles, including 1 inch mineral wool, (insulate the combustible not the duct) X Clearance-3"to Limited Combustible[d]_Clearance-0"to Non Combustible[d] XACCESS PANELS—unobstructed Within 3ft each side of an inline fan _Signs—Access Panel—Do Not Obstruct 20 feet Horizontally[d] At every floor Vertically At every Direction change 10 BURNER RANGE FRYERC I LERI GRIDDLE Access door at vertical riser base _Duct secured to bldg EXTERIOR-Weatherproofed so" 15.5" BROILER aa" —ENCLOSURES-In buildings more than 1 floor,from ceiling above hood or through any concealed spaces ducts shall be 25' enclosed * Penetrate floors&ceilings 6 inches duct to enclosure[a] Vented in curb at roof _Through Penetration Fire Stop System as alternative to Enclosures with 6-inch airspace shall have a minimum 3 inch inclusive airspace, depending on mfg. [d] FAN X TERMINATES-at building exterior up and away from roof X 40 inches from roof X Fan hinges away from duct,with hold open retainer&flexible waterproof cable X Grease drains back to trap at fan X Minimum 10'to air intakes, property lines,windows,doors or 3'vertical X Safe access area for servicing �4 Non-Combustible side wall fan termination ok, no openings 10' horiz,vertical down,32'vertical up, except char broilers not ' permitted ' 1 W J' 05 Pinnacle Hood & Fire Protection Co. Inc. - , Fd 1684 � 965 Wellwood Ave. Lindenhurst, NY 11757 Raf€SSta ��' a PINNACLE 631/ 991-8080 Fax: 631/ 991-8079 2 J :EST. 1958 Job Name: Wayside Market 55575 Main Road Southold, NY 11971 Pasquale 631/ 521-5456 INTERIOR KITCHEN APPLIANCE LAYOUT TO FOLLOW BY OTHERS 4'-61/2" '-2" 11 11 11 n INSTALL(2)5/8"TYPE-X 1/2 BATH ; ; _ FIRE-RATED SHEETROCK ----- ON WALLS AND CEILING KITCHEN WALK—IN '� FREEZER Lu Z 11 4'-0" i 10-101/2" 7'-0" w ' ' NOTE: �' WALK—IN ADD 2X8 RR FREEZER FOOD l2'STEEL COLUMN @12"OC 1 Iw/2'X2'Xi'CONC.FTC. 1 1 (BELOW FLOOR) FILL BLOCK VOIDS•————— STORAGE (3)#4 REBAR EA.)WAY FILL BLOCK VOIDS SOLID BELOW GIRDED 1 1 3"FROM BOTTOM _ 1 1 SOLID BELOW GIRDER .$. (3)1-3/014 MICROLAM (3)1-3/4X14 MICROLAM (2)2X8 GIRDER N .__ REPLACE w/W12X22 STEEL BEAM Ln 1.CONCRETE TO BE 3000 psi 1 C0 6'-3" 15'-li" 11'-6" 10'-4" 2.STEEL REINFORCING TO BE 60 ksi F ie I-1 E cs Z II WALK—IN 30 48 v @ P 1,; 30 48 FREEZER SK HT —4 1 __ SK HT ili , NOTE: ticw r---------------- --- - 1 ADD 2X8 RR ;ram- REMOVE ____ I °� ELECTRIC all%D ell v! SERVICE 2ND. FL. " �O 1 APARTMENT o � 1 2'X3'SKYLIGHT 2'X3'SKYLIGHT —' RO ERI („( — — — — d• \ // 2X8 RR @32"OC E (3) 1-3/4X14 17'-9 /2" 6'-21/2" MICROLAM H A N 0 - j '� I O' CONC.BLK. r` C in o ' WALLS � /*L DELIS +°0 4'-5" OUTSIDE cli SO4 TEEL STORE N �9 .� COLUMN is _ i (� WOOD FLOORING I�T� N ' ' W12X35 STEEL GIRDER ' � 12'-3" `-- N OVER 2X SLEEPERS STEEL COLUMNw/ oe , p tea,- >,••:' j. .• ; aid. a:' e. 2'X2'XS"CONC.FTG. GONG.SLAB FLOOR of;o�- 'X2'Xl'CONC.FTC. ° •• 3)*4 REBAR EA.WAY I 3X3 STEE "FROM BOTTOMTFF— ANGLE HD bo X STORE CROSS SECTION- SCALE: 1/4" = 11-011 R --------------- ------ -- — — — ---- , F R N W I � I Z o E I Q� O z Lo N R , 0 Acli W T U _j x � U-) O � Q OOc0 ' N R I SALES U. z m = I 0 Ci �- - --- - - --------- ------------® ---- '� O c0 � LL � 0 O 1 (V e X O .w 00 j N N ~ pF New OFFICEyp to . 3 ' y R �0• 052.�� A ,..� SS(0N� vJ FRONT (ROAD SIDE) DRAWN BY: JF/MH �- 10'-2 1/2" 33'-6" October 04, 2007 44'-0" Av SCALE: 1/4" = 1'-0t1 FLOOR PLAN ' �i SCALE: 1/4" = 1'-0' SHEET NO: AMENDMENT Panic Bar Equipped Doors Panic Bar Equipped Doors 43'-11 1 2" Le ° Emergency& • Emerg cy& Exit Lights Walk in r1l Ex' ights Freezer Grease Tra Grease Tra Ve Box g I Conv I E El ° I Conv I El I:n Oven I I Oven 1-* Table L- - - --i Rated Wall Mtd `-Hood ire Extinguisher Table Table Meat Locker Table loor Drain ood 11�loor Drain O INN loor Drain loor Drain I-- - - - - - 7rry-eT- -- - -- -, I- -- - - - - - - -- - - - - - - - - -, Food Prep. I ass Trough Window Elect Room I Char Grill BroilerFPO ° True 13 RO <RI True True RO RI True TSSU- TSSU- TSSU- TSSU- IFTI 27-8 27-8 27-8 27-8 yro Lj ME ch Room loor Drain \--Floor Drain —Floor Drain Steam Table Deli �-4�� Steam Table Deli Meat Case Meat Case R O I N Refer. Coffee Table ® l Vent Through Roof ailin Ice Cream g ailing i i i VON i O00i ❑ Steam Table Deli Meat C I I SS Sink Case OI 3"0 PVC Cabinet O❑O Floor Draim 2"0 PVC Floor Drain Office Cooler II I O Hand Vli'ash Sinks I ❑ III I O❑O oO O O I Grease Tra Floor Drain I 3"0 PVC C/ --- To Septic System Panic Bar Equipped Doors Emergency& Floor Drain Exit Lights 3"21 PVC P�,. 0 44—0 S < p� N Fr'�, ;Z. G O. 3.t New W Plumbing Plan Plans are prepared by Condon Engineering,P.C. It is a violation of the New York State Education Law,Article 145,Section 7209,for any person unless acting under the direction of a licenised floor Plan Professional Engineer,Architect,or Land Surveyor,to alter any item in any way.If an item bearing yy the seal of an Engineer,Architect,or Land Surveyor is altered,the altering Engineer,Architect,or Land Surveyor shall affix to the item his/her seal and the ration"Altered by"followed by his/her O p signature and the date of such alterations,and a specific description of the alteration. \ �UFE SS���vP� a* -ZZE,- 2—B—O __- Fate : -oR Condon Engineering, P.C. ` - , c� �� Wayside Market : JJC 1755 Sigsbee Road 55575 Main Road Mattituck, New York 11952 Southold, New York 23-2007 (631) 298-1986 FINAL LOCATION OF COLUMN TO BE DETERMINED BY KITCHEN APPLIANCE LAYOUT BUT N NO LASE SHALL THE INTERIOR KITCHEN APPLIANCE LAYOUT SPAN FROM THE EXTERIOR WALL TO THE COLUMN BE TO FOLLOW BY OTHERS y"} GREATER THAN 25 FEET ���" 4'-61/2" -2" 11'-6" ' a i i INSTALL(2)5/9"TYPE-X 1/2 BATH IRE-RATED SHEETROCK ON WALLS AND CEILING WALK-IN 13 FREEZER FOOD i i 4X4 STEEL COLUMN KITCHEN !�- " w/2'X2'Xi'CONC.FTG. `n tx W STORAGE i i (BELOW FLOOR) w NOTE: WALK-IN (3)#4 REBAR EA.WAY ADD 2X8 RR 22'-0" 3"FROM BOTTOM @12"OC 22'-0" EX.WOOD " EX.WOOD FILL BLOCK VOIDS FILL BLOCK VOIDS SOLID BELOW GIRDER COLUMN ; SOLID BELOW GIRDER COLUMN EX.WOOD (2)2X8 GIRDER® - - - _- (2)Z�S GIRDER: - ® 4V00D _ - - (2)2X8 GIRDER - 04 REPLACE w/W12X22 STEEL BEAM i p CE w/W12X22rrTfEL BEAM REPLACE w/W12X22 STEEL BEAM -y 1.CONCRETE TO BE 3000 psi 5'-10 1/2"COLUMN 6•_0 COLUMN 8'-8 3/4" 9'-10 3/4" Ln N I I 2.STEEL REINFORCING TO BE 60 ksi r"- 5'-10 1/2" 5'-7 1/2" 7'-7" N 1 9'-0" 2'-9 5'-5° WALK-IN N FREEZER _ W ; .-=====--------------- _, ADD 2X8 RR i ice—REMOVE i (ri � , Ca12"OC "' � "' � ,♦,nn :. ELECTRIC W SERVICE " 2ND. FL. APARTMENT r � i — — � — — — 2'X3'SKYLIGHT 2'X3'SKYLIGHT M - - VIT.-9 RO RI 2X8 RR @12"OC E STEEL GIRDER: /2" J6'-2 1/2" 12.3"DEEP DETERMINED BY H 2X4 PLATE 4.03"WIDE MECHANICAL CONTRACTOR A l N LP I o Li C i» b CONC.BLK. ' WALLS � INSTALL(2)5/9"TYPE-X DELI S FIRE-RATED SHEETROCK + 110 4'-S" ON WALLS AND CEILING OUTSIDE c$j SO4 TEEL STORE COLUMN is cli l �. WOOD FLOORING w OVER 2X SLEEPERS I ._°e l.�n:� e•.., n j �a .._ a v".> �,-•.•.i Vie. :e � �< tt. .��� ,� ' � , CONC.SLAB FLOOR s'o f,'.•� 'X2'Xi'CONC.FTG. 3)*4 REBAR EA.WAY I 17 FROM BOTTOM wr 6- I STORE CROSS SECTION SCALE: 1/4" = 1'-0" R �- -—- - - - -- -—-—-— -—-—-—- - - , a F I R W W I ( z G E _ 0 z U.)N I R o A "'� W � pN T V J X J I � Q 00co R SALES � z � O ci M ®-- --------- - ------- ------- -----®-- --- -� O CD cn ..i LL 0 N .ti OFFICE FRONT (ROAD SIDE) DRAWN BY: JF/MH 10'-2 1/2" 33'-6" May 22, 2007 44'-0" FLOOR PLAN SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0' SHEET NO: Panic Bar Equipped Doors Panic Bar Equipped Doors 43'-11 1 2" Emergency& 0 Exit Lights Emerg cy& O E L g Walk In Ex' Ights Freezer Grease Tra Grease TraP-)4/ Ve Box I I I g I Conv IDEE I Conv I DMED Oven I I Oven I Table - - --I o Rated Wall Mtd ood ire Extinguisher Table Table Meat Locker Table loor Drain door Drain go IN loor Drain loor Drain ood r- - - - -- - P - - - -- --- - - -� R- - - - - - - - - -- - - -- - - -- -� Food Prep. I ass Trough Window Elect Room Char Grill Broiler ° RO <R1 RO RI True True True True TSSU- TSSU- TSSU- TSSU- 27-8 27-8 27-8 27-8 yro ME ch Room door Drain door Drain door Drain Steam Table Deli -4 Steam Table Deli Meat Case Meat Case 0 I (V Refer. Coffee Table ® I Vent Through Roof IciCream ailing ailing i i OOO 0 r' F-1 Steam Table Deli Meat Case I I SS Sink I 0 I 3"0 PVC Cibinet OO O Floor Urin 2"0 PVC Floor Drain Office Cooler OHand ash Sinks ❑ III I OO O OO O O I Grease Tra Floor Drain I 3"0 PVC Cll� \7 To Septic System Panic Bar Equipped loons Emergency& - - - Floor Drain -� N��, ��o �o Exit Lights 3" PVC �S1 ,_ Ceti 91 44'-0" Pr ct- New P I u m b i n g Plan Plans are prepared by Condon Engineering,P.C. It is a violation of the New York State Education — Law,Article 145,Section 7209,for any person unless acting under the direction of limensed I e, ;x. •, Floor Plan Professional Engineer,Architect,or Land Surveyor,to alter any item in any way.If an itlem bearing the seal of an Engineer,Architect,or Land Surveyor is altered,the altering Engineer,Architect,or eJ'F �51684 Land Surveyor shall affix to the item his/her seal and the notation"Altered by"followed I by his/her Q �, signature and the date of such alterations,and a specific description of the alteration. orEssdf r r`tm w Scale: 1/4" = V-On Condon Engineering, P.C. wayside Market Drawn by : JJC 1755 Sigsbee Road 55575 Main Road T - r.-:c� Mattituck, New York 11952 Date : 8 -23-2007 (631) 298-1986 Southold, New York