Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
33129-Z
FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-32826 Date: 01/09/07 THIS CERTIFIES that the building ALTERATIONS Location of Property: 930 SEBASTIANS COVE RD MATTITUCK (HOUSE NO.) (STREET) (HAMLET) County Tax Map No. 473889 Section 100 Block 3 Lot 11.5 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated JUNE 5, 2007 pursuant to which Building Permit No. 33129-Z dated JUNE 14, 2007 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ALTERATIONS TO EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR. The certificate is issued to JEREMY PUTTOCK & SARAH GILL (OWNER) of the aforesaid building. SUFFOLIC COUNTY DEPARTMENT OF HEALTH APPROVAL N/A ELECTRICAL CERTIFICATE NO. 3038726 11/15/07 PLUMBERS CERTIFICATION DATED 01/08/08 MATTITUCK PLUMB.&HEATING y Aughorized Signature Rev. 1/81 Form No.6 TOWN OF SOUTHOLD ,1 JAN BUILDING DEPARTMENT Ll 8 6�J TO y WN HALL 765-1802 b Lt_i i7. t:E P T. Tf`1NN OF'SOUTHOLD ` APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or ..topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form), 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and features. unusual natural or topographic 2. A properly completed application and consent to denied, the Building Inspector shall state the reas inspect signed by the applicant. If a Certificate of Occupancy is ons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$25.00, Additions to dwelling $25.00, Alterations to dwelling$25.00, Swimming pool $25.00, Accessory building $25.00, Additions to accessory building$25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy- $.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy - Residential$15.00, Commercial $15.00 Date. f/ sky New Construction: Old or Pre-existing Building: V (check one) Location of Property: '� 60&�� 0b(/e— House No Street ° uC Hamlet Owner or Owners of Property: 5&a- ai j Suffolk County Tax Map No 1000, Section J 0 Block C" UU 7j Lot.. Subdivision zz Filed Map. Lot: Pen-nit No. J 73 v`2 Date of Permit.e2 / 0-7 Applicant: 9610-YKI0 f'i ZZp Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: �� 2� !- heck one) Fee Submitted: $ Applrcan igr re GZk,--- ? 3 C© t 32% �C� FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 33129 Z Date JUNE 14, 2007 Permission is hereby granted to: JEREMY PUTTOCK & SARAH GILL 150 COLUMBUS AVE, APT 7B NEW YORK,NY 10023 for ALTERATIONS TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR. at premises located at 930 SEBASTIANS COVE RD MATTITUCK County Tax Map No. 473889 Section 100 Block 0003 Lot No. 011 . 005 pursuant to application dated JUNE 5, 2007 and approved by the Building Inspector to expire on DECEMBER 14 Fee $ 200 . 00 Authorized S gnatur ORIGINAL Rev. 5/8/02 Vic P� PrJ�r�rJ�rJ��PC fcTTi?PrJ�r�rJ�c.I�rnrJ��PrJ'r�rJ��cPr�C.I�rJ�C.I�rJ�rJ�r�C.tcPC.I�C.nrJcJ�rJ�CJ�C l�rJ�r.Pr.P�.frJ�rJ�rJ�rI&PRI�rJ�cPUPrJN5rlcl�ri 1m a ,F-si , 0° 5 BY THIS CERTIFICATE OF COMPLIANCE THE 5 5 NEW YORK BOARD OF FIRE UNDERWRITERS 5 5 c5 5 TY 40 FULT�ON STREET EETTF NEW RIKI NY 10038 5 5 � � C5 5 CERTIFIES THAT 5 5 5 5 Upon the application of upon premises owned by 5 ,1 5 S5 CUSTOM LIGHTING OF SUFFOLK INC SARA GILLPO BOX 5 MATTI UCK8NY 11952, MATTITUCK 930 I NY 11ANS 9 2E RD. S cS Located at 930 SEBASTIANS COVE RD. MATTITUCK, NY 11952 c5 5 5 Application Number: 3038726 3038726 5 pp Certificate. Number: 5 11 129 Section: BELOV$Iock: Lot: f Building Permit: 33 BDC: ns 5 5 5 Described as a occupancy, wherein the premises electrical system consisting of 5 electrical devices and wiring, described below, located in/on the premises at: 5 5 Second Floor, 5 S 5 A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed 5 5 herein, was conducted in accordance with the requirements of the applicable code and/or standard 5 5 promulgated by the State of New York, Department of State Code Enforcement and Administration, or other 5 authority having jurisdiction, and found to be in compliance therewith on the 15thDay of November,2007. 5 Name QTY Rate Rating Circuit Tyne C 5 Miscellaneous 5 5 SECTION: 100 S5 5 BLOCK: 0003 5 SLOT: 011.005 Cj SROUGH 7/12/07 B.MYERS 5 5 2nd floor bedroom&'bathroom S 5 Alarm and Emergency Equipment 5 SSensor 1 0 Carbon Monoxide 5 5 Sensor 1 0 Smoke CcJ 5 Appliances and Accessories 5 5 Exhaust Fan 1 0 F.H.P. 5 SWiring and Devices S 5 Outlet 9 0 Fixture S 5 Fixture 9 0 Incandescent 5 Outlet 11 0 General Purpose c5 5 Receptacle 6 0 General Purpose 5 SSwitch 5 0 General Purpose seal 5 Receptacle 1 0 GFCI 5 5 Continued on Next Page 1 of 2 5 5 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. 5 �. 5 o ����������������������������������@������ o [J'r�[.n[J�Gf[1�r�[nC1�C1I IE, [J�[J��[.1��1[J�[nrJ�CJ�rJC1[1�[J�[n[J�[P[rL3rJ J�[.f[n[.�[.n[nr�rJ�r�rJ�cl�ct�[J�rJ� 5 5 BY THIS CERTIFICATE OF COMPLIANCE THE 5 NEW YORK BOARD OF FIRE UNDERWRITERS 5 5 S 5 BUREAU OF ELECTRICITY S 5 40 FULTON STREET - NEW YORK, NY 10038 c� 5 CERTIFIES THAT 5 S 5 5 Upon the application of upon premises owned by 5 cS 5 CUSTOM LIGHTINGI OX OF SUFFOLK INC 930 SEBASTIANS COVE RD. cS 5 MATTITUCK; NY 11952, MATTITUCK, NY 11952 5 5 5 5 Located at 930 SEBASTIANS COVE RD. MATTITUCK, NY 11952 5 5 5 Application Number: 3038726 Certificate Number: 3038726 5 5 c5 Cj ns11 33129 Section: BELO\Rlock: Lot: Building Permit: gDC: S 5 5 5 Described as a occupancy, wherein the premises electrical system consisting of 5 electrical devices and wiring, described below, located in/on the premises at: 5 5 5 second Floor, 5 5 5 5 A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed 5 herein, was conducted in accordance with the requirements of the applicable code and/or standard 5 promulgated by the State of New York, Department of State Code Enforcement and Administration, or other 5 5 authority having jurisdiction, and found to be in compliance therewith on the 15thDay of November,2007. 5 5 Name ()Ty Rate Ratin Circuit. Tyne 5 5 5 5 S S 5 5 5 S S 5 5 5 S 5 5 S 5 S 5 5 5 5 S 5 seal 5 5 5 2 of 2 5 5 5 5 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. 5 5 5 o �F�������������� ��� ri����������������� o 0 o C4 = Town Hall, 53095 Main Road Oy �� Fax (631) 765-9502 P.O. Box 1179 ,' � Telephone (631) 765-1802 Southold, New York 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATION Date: ® $ Building Permit No. 3 30 Owner: (Please print) Plumber: o--44P/001 L t (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. p (Plumbers Signature) Sworn to before me this day of 20 ,99 DENISE KING At-4ry:Public„State'0CNew Y' R- Or ltionir#01,K1604� 57� al Wd i►r,S0ffbIk-Odaltty MY Comrtiison.Expires.Ma :T5,=2_.J/_o Notary Public County pF SOUTyolo 9UM`1,�c� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY /[ \] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: d DATE ���� INSPECTOR . ho�aOF SOUlyolo � 31 ?,-7 cou tom, Oc� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST KROUGH PL13G. /6 r [ ] FOUNDATION 2ND XINSULATION xoAMINGSTRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: DATE �� �� INSPECTOR FIELD INSPECTION REPORT7 DATE I COMMENTS W� FOUNDATION(1ST) �1 H ------------------------------------- FOUNDATION(2ND) ct 0 a H ROUGH FRAMING& PLUMBING H y INSULATION PER N.Y. - -- ellS STATE ENERGY CODE (b FINAL ADDITIONAL COMMENTS O � b T � O z H b H NOON■■■ ,, ■I��i�■il��■■■■ s.. ■■■■■iiii�ii■iilEi�■■■�■ ' 'r•?/i.,S "J. ' ` g i ■■■■■„■■��■�■��®NOON ?. } I•.9 51 , ' LiGr�lt Jig • v_ ■■■■■,�■■■■■���■■■�■■■ pel NONE■■ E■■■®E ■ENO■ ■EON■■ ■■■EMMOEE■E■■ = - NOON■■ ■■■■■■■■■■■■■ .. Foundation FloorFire Place Rooms 1st • TOWN OF SOUTHOLD- PROPERTY., RECORD CARD OWNER STREET Cl 0 VILLAGE DIST.1 SUB. LOT T e.rtm� Oc4r_ * GOA Ir:r�+r��'i i�; -'"}d � 1�`_ icy, `,'•`1` f�-- � f 7 Q' c 1,.'' Gt l: FORMER OWNER N E ACR. SXrz�-P,ecf,- -le, mjc ate ' S W TYPE OF BUILDING RES. / SEAS. VL. FARM C6Mlv1. CB. MILS. Mkt. Value LAND IMP. TOTAL DATE REMARKS - s"et" _(.1 �.� Y lJ .. �`^'iC'L-A �."q+....�I 1 6 In 0 - fi r: en .a" I 1`�! r . )ur-( L-9vi ""1 `ru_} t..l c� � '�rS �l � f�";7 "�� r�i:. ! } ; '•`y Ica \` l_ C I 1 - .� .�' c 3 , t J! )C� .1. Y.i I i "� l �.�. V~'�-/ �,. t 3 0� d ems•. ,�F- 7sl ��f a t�IV I Tillable FRONTAGE ON WATER R Woodland FRONTAGE ON ROAD Meadowland `-5 r ;,� {:1 .�-ice� ;�f+�r DEPTH House Plot a; � .{` BULKHEAD Tota l j '"r i TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL , Board of Health SOUTHOLD, NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey www. northfork.net/Southold/ PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees Examined ,20 Contact: Approved 120 Mail to: Disapproved a/c Phone: Expiration ,20 - ----- ;._--- Building In o for JUN 5,2007 A�rlj P CATION FOR BUILDING PERMIT Date / , 20_!�X INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months.Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations, and to admit authorized inspectors.on premises and in building for necessary inspections. (Signatur of p 'cant or name,if a corporation) �'Z)•�O 79 �p (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder Name of owner of premises S/�fL kr �-� Pa_b4D C,�. (As on 6e tax roll or latest deed). If%cant is a corporation, signaturof duly authorized officer u� (Name and title of corporate officer) Builders License No. h-,Z 6 -7 7 Plumbers License No. 61 3 6" P Electricians License No. `3 E!> r M Other Trade's License No. 1. Location of land on which prop sed wo k will be d e: House Number Street Hamlet County Tax Map No. 1000 Section / Block 3 Lot A s Subdivision Filed Map No. Lot (Name) 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy ti ' d b. Intended use and occupancy 3. Nature of work (check which applicable): New Building Addition Alterati n _. Repair Removal Demolition k � (Des ription) 4. Estimated Cost 30� Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES N9-1 13. Will lot be re-graded? YES NO_Will excess fill be removed from premises? YES NOA 14. Names of Owner of premises 6,. 1 P,44cy� Tess Phone No. Name of Architect Address Phone No Name of Contractor oN 1V LZ?-0 Addres -yf 7�T yu bgj To. �7 .5-s- 7 72- 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUN F ) , TXOY) being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)He is the (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn before me this a of 20 All- otary Pu lic Si at of Applicant LINDA S. CARLSON Notify Publlc,State of New York No.01 CA6137178 Qualified in.Suffolk Coun COMMIssion Exbirep N9v_. 1a. 06/13/07 WED 16:09 FAX 10002 f . Southold Town Building Department: Ref. Sarah Gill,930 Sebastians Cove Mattituck NY 11952 Damon Rallis, Please be advised that the pitched ceiling finished height in the proposed bathroom is.as follows;at the highest point 12'-T'to the lowest point 9'- 3".At no point is the ceiling any lower than 9'-3". Thank You, John Rabkevich Penny Lumber Drafting Dept. 06-13-2007 15:11 SOUTHOLD BUILDING DEPT 16317659502 PAGE2 Permit# Permit Date REScheck Software Version 3.7 Release 1 b Compliance Certificate Project Title: Gill Puttock Report Date:04/29/07 Energy Code: New York State Energy Conservation Construction Code . Location: Suffolk County,New York Construction Type: Detached 1 or 2 Family Heating Type: Non-Electric Glazing Area Percentage: 6% Heating Degree Days: 5750 Construction Site: Owner/Agent: Designer/Contractor: 930 Sebastians Cove Mattituck,NY 11952 Assembly • - - �.. Ceiling 1:Cathedral Ceiling(no attic): 235 30.0 0.0 8 Wall 1:Wood Frame,16"o.c.: 280 19.0 0.0 16 Window 1:Wood Frame:Double Pane with Low-E: 18 0.350 6 Statement of Compliance:The proposed building represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application.The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code. 01 Builder/Designer Company Name Date S 1® Gill Puttock Page 1 of 4 r REScheck Software Version 3.7 Release 1 b Inspection Checklist Date:04/29/07 Ceilings: ❑ Ceiling 1:Cathedral Ceiling(no attic),R-30.0 cavity insulation Comments: Above-Grade Walls: ❑ Wall 1:Wood Frame,16"o.c.,R-19.0 cavity insulation Comments: Windows: ❑ Window 1:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Air Leakage: ❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. ❑ Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: ❑ Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: ❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment must be identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. ❑ Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: ❑ Supply ducts in unconditioned attics or outside the building must be insulated to R-8. ❑ Return ducts in unconditioned attics or outside the building must be insulated to R-4. ❑ Supply ducts in unconditioned spaces must be insulated to R-8. ❑ Return ducts in unconditioned spaces(except basements)must be insulated to R- ❑ Return ducts in unconditioned spaces(except basements)must be insulated to R-2. .Insulation is not required on return ducts in basements. Duct Construction: ❑ All joints,seams,and connections must be securely fastened with welds,gaskets,mastics(adhesives), mastic-plus-embedded-fabric,or tapes.Tapes and mastics must be rated UL 181A or UL 181 B. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). ❑ The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ❑ Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: Gill Puttock Page 2 of 4 r ❑ Separate electric meters are required for each dwelling unit. Fireplaces: ❑ Fireplaces must be installed with tight fitting non-combustible fireplace doors. ❑ Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: ❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: ❑ Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: ❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20%of the heating energy is from non-depietable sources.Pool pumps require a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. Gill Puttock Page 3 of 4 Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Temperature(°F) Up to 1" Up to 1.25' 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range ff) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) Gill Puttock Page 4 of 4 06/13/07 WED 16:09 FAX 10002 f., �r' a Southold Town Building Department: Ref. Sarah Gill,930 Sebastian Cove Mattituck NY 11952 Damon Rallis, Please be advised that the pitched ceiling finished height in the proposed bathroom is.as follows; at the highest point 12'-7"to the lowest point 9'- 3".At no point is the ceiling any lower than 9'-3"- Thank You, John Rabkevich Penny Lumber Drafting Dept. 06-13-2007 15:11 SOUTHOLD BUILDING DEPT 16317659502 PAGE2 PLUMBING a ALL PLUMBING WASTE _ &WATER LINES NEED APPROVED A� �OVE® AS NOTED TESTING BEFORE COVERING DATE:�, � g,p,�,�3 COMPLY WITH ALL CODES OF 1d�1� � ® NEW YORK STATE & TO':1.- � CODES w FEE:12QDL. OY; TION AS REQUIRED AND CO" 'TiONS OF NOTIFY BUILDING DEP M T AT BTIFIDA FQ�E SOUTHOLD" - 7F5-1802 8 AM TO 4 PM FOR THE R GE 1 gE GY a FOLLOWING INSPECTIONS: UM�� t4,f &AN � ),— �r� N pi. CO pG SOUTHC.' N, yG BOARD I. FOUNDATION - TWO REQUIRED L�p QF � �`GR r q FOR POURED CONCRETE A-�I�ICA�E Ep IN WA NQT ._ SOUTH-, 2. ROI.'uFl - FRA '!NG & PLUMBING GE pER US TEM GAN EAp. N.Y.S uG z 3. INSULATION cJ.QI. SYS �o L 4. FINAL C'i.'��RI CTION MUST SUPPLY 210 OF o N oac cai c > /. A /' BE CCMPLE1E F011 C.O. EXGEEp ��.9 o y o m /I ALL CONS T PUCTION SHALL MEET THE �'t�JEF;;" ",�CERTIFICATE — :' REQU!RE '-'N T S OF THE CODES OF NEW REQUIRED 'IRK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. OC U .. „r Ji'' L-AWFUL \ yre-.ly TCERTIFICATEp OF OCCUPANCY a KNEE .G✓AGG.S' HGT R�G� fIRE4` "=-',� 5��• � O Z'z 2 Z _ �\,�'pN EQ�\�� ��`�•S�� � � A40T�':- c3 i0�o'� �� �n �` F ER �•y N M m o1 T_ POST /EfI DE.4 1 2-4x6'7 I i,h N B/FILL D DU0�5 Go o Z � r L 1/E- 9.3•,G✓,9L-G W •- r� CC W B,9 Th' aQ /6=6"OF"EN/N:a_ ._A T YLL 49.97-H o Z Z so liY e N � -STdRAGE.... ._..:_._ V G I I /c� ,Kt. ,rQ ,r: x �; }� ' All � r 2 N~ o w (� 0: Q -b 10 N 10 A STRUCTURAL WOOD PANELS FOR WIND-BORNE DEBRIS PROTECTION FOR WALL OPENING PROTECTION OF120 MPH 3-SECOND WND GUSTS (MAXIMUM MEAN ROOF HEIGHT:351 `WINDOW AND DOOR SCHEDULE 1 _ ..._ ._. -.._.... . MULTIPLE SECTION ASSEMBLY: 1/4R�e i� .; p� S �f •+ ,` '. ,• ; t �` "` " "z' q (/� ^ °"`y,: iw -j.a, :Frei,t. )'d' `''° '� 'r,""'uJr`% ,.•• we.i4^e v4o ,� - 'f A : "� f, • "vdr;�'. THICK BOLTS @ 2 OC r.`� -� �,. �: .�: ,.,..�'��. ,�, � • �« '' ~' �,2 *1- ,A. � ., .. /d ¢ 25. -28. oP-3U B �r'/.rC3 Ti' i.�.:,J/t) 1'�46X/ FiQAN/E 9,Q /O 4• -28•/ �P-30 N C .9 5/ Al�t/NV/�VC� z.5" 7.S' 20 S , 24.7 -3 , I,C 50 E' 23.2 -25.¢ B-/ .9� 2 As✓�//NG D. 8 t 7 /O 4- 25.9 -29, 0 z Ld w U Q > A N A Ora ALL WINDOWS TO BE ANDERSEN HIGH PERFORMANCE OR APPROVED EQUAL i I I �I CALCULATIONS FOR WINDOWS BASED UPON EXPOSURE B M UST HAVE DP UPGRADE KIT. F E 'MEETS NY STATE EGRESS REQUIREMENTS COEFFICIENT 1 .0 WITH 120 mph BASIC WIND SPEED. AS PER ! IREMENTS (TABLE R 301 .2 (2) NEW YORK STATE BUILDING CODE . ( FOR HABITABLE SPACE . I ( iCUSTOM GRILLES - SEE ELEVATIONS i i ! _ ..i . . V Q IW TLL OPENINGS INCLUDING WINDOWS AND DOORS SI I - . ; HALL BE PROTECTED W ITH REMOVEABLE 5/8" WOOD STRUCTURAL PANELS 1 O 1 H MAXIMUM OF 8 0 SPAN . FASTENERS FOR SPANS UP TO 6 -0 SHALL BE 2 1/2 - # 8 WOOD SCREWS AT 16" O/C, FASTENERS -FOR SPANS UP TO 8'-0" SHALL BE: 2 1/2" - #8 AT 12" O/C. TABLE 301 .2.1 .2 - I 'ALL NARROLINE WINDOWS MUST USE : ; 1/2" HEIGHT SILL STOP (OR STOOL) AND THE ADDITION OF A 1/2" X 3/4 DP UPGRADE SILL STOP . (SILL STOPS TOTAL A 1-1/4" i o Q'HEIGHT AND REQUIRE THE _INSTALLATION OF A SPECIAL SASH LIFT INCLUDED WITH DP UPGRADE SILL STOP KIT.) co O 'n !/EN T a o Tf/RL/ f�OD� w SHUTTER ASSEMBLY wp'IT jr N.T.S. r M FOR PANEL SPANS:0<4'-0"WIDE SPAN TABLE 1609.1.4 ' i / Q } o 23/32"APA SPAN-RATED 48/24 SHEATHING GRADE PLYWOOD(OVERLAP AROUND OPENINGS 4") -�' I p Z o USE AC GRADE W/2 COATS EXTERIOR PAINT 2 SIDES,4 EDGES. 12 Z ,- LABEL ACCORDING TO LOCATION. �� �2 I � ci ASSEMBLY: I c0 ATTACHING STRUCTURAL PANEL: FASTEN TO BUILDING w/#8x3"(w/WASHERS)GALVINIZED OR STAINLESS STEEL WOOD SCREW @ 16"O.C.OR BETTER ALTERNATIVE FASTNER FOR SHUTTER TO BUILDING: ( _WC #10 TEE NUTS ATTACHED TO BLDG.w/#1Ox 1 Y"(W/WASHERS)MACHINE BOLT @ 12"O.C. I WHERE SCREWS ATTACH TO MASONRY OR MASONRY STUCCO,THEY SHALL BE ATTACHED UTILIZING VIBRATION RESISTANT ANCHORS HAIVING A MINIMUM WITHDRAWL CAPACITY OF 490 lbs. I --s'-la d-R Sri�L. I SHUTTER ASSEMBLY N.T.S. I FOR PANEL SPANS:4'-0"OR WIDER SPAN W SPECIFICATIONS AND ASSEMBLY IDENTICAL TO 0<4'-0"SPAN. ~ NOTE ADDITIONS: Z 2." 3 �701 U 2x4 STRONG-BACKS @ 24"OC C7 C`L�:9N DL/T ? ASSEMBLY: w 1). PREASSEMBLE PLYWOOD TO 2x4'S:#10x3"(w/WASHERS)GALVINIZED OR STAINLESS STEEL WOOD SCREW @ 12"O.C. TD EX/5`T/,1'U ALTERNATIVE FOR OPENING PROTECTION QZ Q WOOD STRUCTURAL PANELS WITH A MINIMUM THICKNESS OF 7/16"AND MAXIMUM PANEL SPAN OF 8'-0" _ _ _ SHALL BE PERMITTED FOR OPENING PROTECTION IN ON AND TWO STORY BUILDINGS. PANELS O SHALL BE PRECUT TO COVER GLAZED OPENINGS WITH ATTACHMENT HARDWARE PROVIDED. (REFER TO SECTION 1609.1.4 AND 1609.6.5 AND TABLE 1609.1.4) k.: PL, ° ` TABLE 1609.1.4 ;:'-':fir• . WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS r1 �-� FASTENER SPACING INCHES PANEL SPAN < 2' 2'-0"< PANEL 4'-0"< PANEL 6'-0"< PANEL FASTENER TYPE 0" SPAN <4'-0" SPAN < 6'-0" SPAN <8'-0" 1 ' r , f 2 1l2" #6 WOOD SCREWS 16 16 12 9 2 1/2" #8 WOOD SCREWS 16 16 16 12 A THIS TABLE IS BASED ON A MAXIMUM WIND SPEED (3 SECOND GUST)OF 130 MPH AND MEAN ROOF V HEIGHT OF 33'-0"OR LESS B. FASTENERS SHALL BE INSTALLED AT OPPOSING ENDS OF THE WOOD STRUCTURAL PANEL. C. WHERE SCREWS ARE ATTACHED TO MASONRY OR MASONRY/STUCCO, THEY SHALL BE ATTACHED UTILIZING VIBRATION RESISTANT ANCHORS HAVING A MINIMUM WITHDRAWL w L� CAPACITY OF 490 LBS. IN < O