HomeMy WebLinkAbout33017-Z FORM NO. 4
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Office of the Building Inspector
Town Hall
Southold, N.Y.
CERTIFICATE OF OCCUPANCY
No: Z-32749 Date: 11/26/07
THIS CERTIFIES that the building NEW DWELLING
Location of Property: 650 COTTAGE WAY MATTITUCK
(HOUSE NO.) (STREET) (HAMLET)
County Tax Map No. 473889 Section 122 Block 2 Lot 23.17
Subdivision Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore
filed in this office dated APRIL 25, 2007 pursuant to which
Building Permit No. 33017-Z dated MAY 8, 2007
was issued, and conforms to all of the requirements of the applicable
provisions of the law. The occupancy for which this certificate is issued
is SINGLE FAMILY DWELLLING AS APPLIED FOR.
The certificate is issued to CDCLI HOUSING DEV CORP
(OWNER)
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL R10-07-0032 11/09/07
ELECTRICAL CERTIFICATE NO. 117996C 11/02/07
PLUMBERS CERTIFICATION DATED 09/12/07 CHARLES BRUNO
uthorized Signature
Rev. 1/81
Form No.6
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
765-1802
APPLICATION FOR CERTIFICATE OF OCCUPANCY
This application must be filled in by typewriter or ink and submitted to the Building Department with the following:
A. For new building or new use:
1. Final survey of property with accurate location of all buildings, property lines,streets,and unusual natural or
topographic features.
2. Final Approval from Health Dept.of water supply and sewerage-disposal (S-9 form).
3. Approval of electrical installation from Board of Fire Underwriters.
4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead.
5. Commercial building, industrial building, multiple residences and similar buildings and installations,a certificate
of Code Compliance from architect or engineer responsible for the building.
6. Submit Planning Board Approval of completed site plan requirements.
B. For existing buildings(prior to April 9, 1957) non-conforming uses,or buildings and "pre-existing"land uses:
1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic
features.
2. A properly completed application and a consent to inspect signed by the applicant. If a Certificate of Occupancy
is denied,the Building Inspector shall state the reasons therefor in writing to the applicant.
C. Fees
1. Certificate of Occupancy-New dwelling$25.00,Additions to dwelling$25.00,Alterations to dwelling$25.00,
Swimming pool $25.00,Accessory building$25.00,Additions to accessory building$25.00, Businesses$50.00.
2. Certificate of Occupancy on Pre-existing Building- $100.00
3. Copy of Certificate of Occupancy-$25.00
4. Updated Certificate of Occupancy- $50.00
5. Temporary Certificate of Occupancy- Residential $15.00, Commercial $15.00
Date.
New Construction: Old or Pre-existing Building: (check one)
Location of Property: 1 .2 lj �nQ, m/,,T41u_e_k
House No. eet Q, Hamlet
Owner or Owners of Property:
Suffolk County Tax Map No 1000, Section Block D Lot
Subdivision l Filed Map. Lot:
Permit No. j b �� Date of Permit. Applicant:
Health Dept. Approval: Underwriters Approval:
Planning Board Approval:
Request for: Temporary Certificate Final Certificate: (check one)
Fee Submitted:$
c
A licant Signature
3�
ca i 3 V I
FORM NO. 3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Town Hall
Southold, N.Y.
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL
COMPLETION OF THE WORK AUTHORIZED)
PERMIT NO. 33017 Z Date MAY 8 , 2007
Permission is hereby granted to:
CDCLI HOUSING DEV CORP
2100 MIDDLE CTY RD
CENTEREACH,NY 11720
for I
CONSTRUCTION OF A NEW SINGLE FAMILY DWELLING PER PLANNING BOARD
APPROVAL AS APPLIED FOR
at premises located at 650 COTTAGE WAY MATTITUCK
County Tax Map No. 473889 Section 122 Block 0002 Lot No. 023 . 017
pursuant to application dated APRIL 25, 2007 and approved by the
Building Inspector to expire on NOVEMBER 8, 2008 .
Fee $ 776 .40
Aut orized Signature
ORIGINAL
Rev. 5/8/02
r`==✓-mac =:=U•= :''-y_ ,-_ c
ai+r,�.':••:i•F i0�`rr•♦.O�;��•n•tE�rr..••:p•.A,•o-'.j F i0�r'q4:.+•.z•�•a��«:.s•.�^•t�`cr•i,'.q••»•o•.•i'i�r.r•',q:;••:i•y••9 y�Ocr.S t•Y.�'•,,�9♦s.r.• 'A.•.••.�rr:•p�_•S•• t..••p'gn•r•p+•nfip,p t �s,pr.'•p.+�".p•�n£amrr••••.,py�-3,�y+"`.p.,+.'�yu nf���<•�:.,,�.:a�,r.i'..ceS,•'s v' ,rr•�S,:e,•s.�3+i•♦r r4•'..❖,.s?a.aN.so�•O�'♦1�4�'.•:•%••:?O'«'3•��F ri•t,v,'Js'.•1 tiF,rp,r❖.'2 A•-••a♦;:
... .� ••t...•• o'i.r.. .t..••ni...•..r.. r..Ci•t r.. . F'• t
�i�♦�% pPP01 �.•OtiJ f••••Pi•J• tt•.pA,' Ott••' �t./r ` tr tt•1 `t.r/ `�.t. ' .n t.h' P••r h.t te• •.. J tr• �+•'0•ti t•1�1••ri,' IOti•Q) �0•//i)��♦">lt•'/'•'���trr/ •♦t:��.
!+•.t'•O N11{� 114 1♦•111. 1t11 �f•t�t•1 �I/ft•����•t�1/1f{"�•, 1•/�1•11 �•f/1/11 �f'1•,t/f/l�.•,`.1•1/t/t/ �fllt/t•11 � f11111/ t/ttll�, �t/l///ly t//t/Ill{.,,�Q/t/1•1. �, fN��1N1{%�•,� /{�•,.tl/114'�, If. ,�tlf/1H. ,♦J••
�:.� � Inrx��1�, ntaf 1 nr ,tt.uf.�,�lVtf fl �t flr�, farr���flr fl'tlflrp�af�r �;.vNl►f �.f+r61; ,flrr4r ,f1 a:� r 11 -�rfr.nrj;a r 1rf.�.fttfrlr•,. .. 4/irr„.��t►rr r�f Ott ,�,.;,flrtt' .'+s�
F �II ��'��� r�r �'�� � ,fI �k �Ir„ ,r►"� ' �1r r� rl'tt� �t r��. tl'�f �t t+� �t'�f nM►�t' rtr�f t'��- �n'» �t4f� tt �+ t,���� +4t l�;, th �+ t►
- Electrical Inspection Certificate
t; Issue Date Electrical Inspection Service,Inc. Application Number
r{' 11/2/2007 375 Dunton Avenue 117996C - y
East Patchogue,New York 11772 =_
(631)286-6642 .
Issued To: Island Estates East LLC (Job# 16) -y �
Street: 650 Cottage Way
Village: Mattituck Zip: 11952 Town: Southold
Section: Block: Lot:
" Contractor: Newbridge Electric of U. Corp. Lic.# 3857-E �=
Was examined and found to be in compliance with the National Electrical Code.
❑ Commercial ❑ NV Defects ❑ Pool ❑X 1st Floor ❑x Indoor X❑ Basement ❑ Hot Tub
'' X❑ Residential ❑ Det.Garage ❑ Attic ❑ 2nd Floor ® Outdoor ❑ Addition ❑ Survey _
1.❖, .v:
Switches Receptacles Fixtures GFI Heaters A/C Fans >.t
Dishwasher Washer/Amps Dryer/Amps Oven Range/Amps Microwavesw
' 1/20a 1 Gas 1/20a '= +
. •
•;` Furnace Oil Gas Circulators Smoke Detector Bell Transformer
N 1 x 1 4 1
Meter Amps Phase UG/OH Jacuzzi Television CO Detector -
1 150 1 x❑ / 1
Bldg. Permit: 33017
_ Other Equipment
1-150 amp M/B Panel
1-30 am[W/D combo disc. -�
Hugo S. Surdi xy:,
- President
Rough Inspection: 07/25/2007 "
Inspector: John McMahon III
Final Inspection: 10/31/2007 " - }
f Inspector: John McMahon III a
• _ This certificate must not be altered in any manner. Inspectors may be identified by their credentials.
♦
f `r�,b r' t ►r +► + � � 1 r i►f f1f rf r�+f o 1f
+ /1 H Nfi 1 1 M/ 'Ni l�li li/ie 1 lili/i11 l/il I/il t/y i 1• �,�t ( •11 .t ';q$, ;•�.j., 11111 ,1•• 1 ,�•1 1 1 // 1 1♦ ,.� � '1Y' �� ,.!f�,.,, �' +�
/h• L�•�• 1•�,..,�', � t•f , •9�4� /. /. /i•�,., • •tit t,,t. h0��, . • /•. .•,� ••0 t• ♦.%+O�S• �i
r•.:•..oa,w..• J+ •>ti.+'• �..;:.0 4p'..•yo e�o.•'.o yy:;.;:;tr, w:;.n ..♦.o y'�st'.o�'S o�y.q n'�+=• ' •v �'d+�f:,.rV,+F•• V�4•'•• wY+ . -`` w ., m e••�:+
♦�^♦�•''_'%��T%♦-,•.� �r��3 '��+-era '':+� <'r +♦='':r g'�'':'.'�r -ski:r >i F�s��r �vw'r ♦���i ♦'.:�j+ '%.?�� i�%e ♦ � ♦ it 'Li$'.A ::�:L'+ tij:�r +:,•✓j ��jr Es�:,i
e� R�
9`
Town}loll,5309$MAIn Roof Fax(631)765.1833
P.O.Box 1179 Tolrplsorte(631)76S-lttll2
SgtJrttold,New York 1471.0959
auRMTKO DUARTM>ENT
Town OF SOUTHOLD
CERTIFICATION
Date:
Building Permit No. jD
Owner: CDLLM
(please print)
Plumber: 1'-WA J / ll l
(please print)
I certify that the solder used in the water supply system contains less than 2/10 of 1% lead.
(Plumbers Signatur
Sworn to before me this
day of E 20_
l
Notary Public, S County
SOPHIA SMIMMO
Notary Public State Of New York
No.4604011
Qualified In Suffolk County
Term Expires February 28
MAILING ADDRESS:
PLANNING BOARD MEMBERS S 0 P.O. Box 1179
JERILYN B.WOODHOUSE Southold, NY 11971
Chair
OFFICE LOCATION:
KENNETH L.EDWARDS Town Hall Annex
MARTIN H.SIDOR G Q 54375 State Route 25
GEORGE D.SOLOMON :rhl (cor.Main Rd. &Youngs Ave.)
JOSEPH L.TOWNSEND Cou Southold, NY
Telephone: 631 765-1938
V11 Fli
PLANNING BOARD OFFICE Fax: 631 765-3136
TOWN OF SOUTHOLD
MEMORANDUM
To: Building Department
From: Anthony Trezza, Senior Planner
Date: November 26, 2007
Re: The Cottages at Mattituck
It has been brought to the Planning Board's attention that the Building Department is
preparing to issue Certificates of Occupancy for a number of residences in the recently
constructed Cottages at Mattituck. Please be advised that the Planning Board has no
objections to the issuance of the CO's because the builder has agreed to complete the
installation of the monuments within 60 days of the date of this correspondence. In
addition, the Town will not release the bond until such time as all work is completed.
MERCURY TEST CERTIFICATION BY CONTRACTOR
DATE:
Plumbing Contractor: Park Avenue Plumbing Corporation
Address: 856 Johnson Avenue Suite 2 Ronkonkoma,N.Y.11779
Telephone: (631)981-3800 Fax: (631) 981-3861
Plumbing License# 1543P
Name of Licensee: Charles Bruno
Owner of Prope C—L
Address of Property: y
SD
Section 1 )-� Block 0(M-,)- Lot
Permit# House# --t-�Gcs
Telephone#of Owner:
Type of Gas (LP) (NG) /
I certify that I am a licensed Plumber in Suffolk County and have performed on this
date a mercury test on existing or_ �new(please
check) gas piping located at the address above and that no gas leaks were detected.
Licensed Plumber
License# /S-X? ,P
SOUjy�lo
At /6
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION
[ ] FRAMING / STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
REMARKS:
off ,
1
DATE INSPECTOR
OF SObryo�o
33 017 ,z- -
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1 ST [ ] ROUGH PL13G.
[ ] FOUNDATION 2NDINSULATION
[ ] FRAMING / STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
REMARKS:
�Z2
DATE �� ��� INSPECTOR
OF SO(/lyolo
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND INSULATION
[ ] FRAMING / STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
REMARKS:
.A
DATE INSPECTOR
OF SOU
�3 J�o z— o .
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1ST 0<1ROUGH PL13G.
[ ] FOUNDATION 2ND [ ] INSULATION
FRAMING STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
REMARKS:
azt_wl�:4)
0�
DATE / INSPECTOR
�o�aOF SO
® � � �
courm,��'
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] DOUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION
[kFRAMIN STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
REMARKS:
DATE INSPECTOR r
OF SOl/,yo�o
3,3 7
couMv,e
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[�] FOUNDATION 1ST [ ] ROUGH PLBG.
[/ _] FOUNDATION 2ND [ ] INSULATION
[ ] FRAMING / STRAPPING [ ] FINAL
[ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
REMARKS:
Opt,
DATE -- ® '7 INSPECTOR �.
OF SOUjyo�o
® ,�' • ao
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PL13G.
[ FOUNDATION 2ND [ ] INSULATION
[/ ]\ FRAMING / STRAPPING [ ] FINAL 4
[ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ) FIRE RESISTANT PENETRATION
REMARKS:
DATE INSPECTOR '
FIELD INSPECTION REPORT DATE I COMMENTS
FOUNDATION'(1ST)
G �
-------------------------------------
FOUNDATION(2ND) 1117
z
0
H
ROUGH FRAMING& -3 —
Gy
PLUMBING
IF
INSULATION PER N.Y. — y
STATE ENERGY CODE
cn^_
TAP o -
FINAL
ADDITIONAL COMMENTS C�
ra
m
z
C)
� o
i�
O
Sjj
J �{y"
ro
y
LAND NOW OR FORMERL Y OF
S41LLIVAN
(WELL/PRIVA7F SANITARY)
" 63.52'
LbT 1'a
4�6
AREA=�8,b00\S.F:,,NATURAL NON\DISTURBED VEGETATED BUFFER
r�- 28.2+ +.�- 28.8
04 ( O
N i 00
M z DO
16.8, �i1 N
LOT 15 o 30.1' + r- LOT 17
00 ad
N Orl
" FRAME RES. " +\)
FFL=29,6
ROOF
OVER 7.7' 17.1 I
c 29.0
3 17.0' 295
R (
( a V
00 N M "J� rn I S O
N a� S.T. N vil iI N
O + al N
W L.P. �3 :n
N 1 T21'04 W R-1 p I N z �0
- a `r' TC 25.55 38.42' L_ 0•plp' J
O , n�, CONC. CURB 6.9 + 667.47� O
�O
TC 26.68
> --• ~---- WATER MAIN
O
I ZDL:."b•e-',,.j1,l.L.:'f.';; .-.. d {�'l•.;i� .J'8lie(".Laau •tm�au!".d'e:alZl
it= s (BIT. SUB. P
�J
_
NOTES• Nov 0 T-2007a � _n. ,;•, G�(U_07 uC�-
WATER SERVICE, SANITARY, AND DRAINAGE F r,;,•^,;:��-�_
SYSTEMS LOCATED BY OTHERS.
LOCATION, TYPE, AND SIZE OF UNDERGROUND UTILITIES
SHOWN ON THIS SURVEY MUST BE VERIFIED PRIOR TO E ANY CONSTRUCTION AND/OR EXCAVATION. ADDITIONAL -�
UNDERGROUND STRUCTURES, IF ANY, OF WHICH THE
SURVEYOR IS NOT AWARE ARE NOT SHOWN. c,• ,y ;,^•
11-5-07 ADD CERTIFICATION
SCTM DISTRICT 1000 SECTION 122 BLOCK 2 LOT 23.17 9-19-07 ADD WATER SERV. AND SAN H.C. LOC.
NELSON s. POPE, LL-P
ENClINEERS • MESIC IINERS • SURVEYORS
572 WALT WHITMAN ROAD, MELVILLE, N.Y. 11747-2188
- - - (631) 427-5665 FAX (631) 427-5620
FINAL SURVEY OF LOT 16 7W 01WM(OR SHMN
HUE-ON FROM TM UnWC1U@B TO
YM PROPWff LIJ M AIE FOR A
WECRC KWOOE AND UBE AND
MAP OF COTTAGES AT MATTITUCK" TH3E WME NW lR�TO
OLOE TM EREOWN OF FaL=
FILED JANUARY 30, 2007; FILE No. 1J0491` 'a"� �MU Aro'
SITUATED AT _ ao f.. ;r ,"• \- TO MRMX.M—AM ANY OTHO
WHW� e�e
zM1 t>.h KWAFED.AND ON HE B80 F M TFE TRLE
CIDWANY,G 7430A NYAL A0810Y AID L8DM
TOWN OF SOUTHOLD,%/ S�#J QLK� OUN `y`t', NEW YORK NMU11oNU—HUWON.AND TOTM
GUMANTEN CERTIFIED ONLY TO ROXANA L. CRU• l; MWAFffVZW
ORT `_" ";),'• ANK, a IMSION OF MMUTIO SOR TO
r't WMTHOMW ALTERATION OR
OWNM
DATER CAPITAL ONE, tS, FID :.; q x10N E INSURANCE COMPANY ADOMONMOLATION70��
Fi D P I --LOC �° L' 3"1~`' °
SCAL 30 NEW YOW BYAIE EDUCATION LAW.
'a, �. �� E•1 OOM OF THB BUfl w MAP NOT
q BEMM TFE LAID MNEYM PION
B P P P FINAL 10 19 07 ° , ��°', ,JOB NO. 02007 e�oa+eOeg��toe��NDooPv.
`�"--q•— NO PM181CAL EAGEMEM ON PROPERN
WOW CA
S O. AEAB1iB, oTDFOUIDATION FILE NO. 1000-112-1 wCtF+rw®F 8FEA1MAffiME
U.B.BfANDAFD OF 1EA8lfE1,FN18NOT
I nT Is TM-E NO.
(,7
1.
JUL 30 20`7
LAND NOW OR FORMERLY OF PY.
SUILIVAIV DE
(;IEL LIPRI VA 7E SANITARY) (',,
--l�L19*04'40" W 63.52'
LOT f6.
AREA* ,wo's.F.'-,".
25.'�NON-DISTURBED VEGETATED BUFFER.
04 "0
04 00
Ki 05
CELLAR ENT,
16.8' C14
LOT 15 30.1' LOT 17
(VACANT) (VACANT)
b
1 STY. RES.
FND. ONLY
[TOP OF FND=29.4]
7.7'1 17.1'
17 Cr
Ld
0 r �v
00 0
C14
Fq ui
z
cn
Z
4.' R n A�-
N 182424fp W R�=100.0
0
PROP. EONCCQmo L=:26.9 667.47'
c�
Co TTA GE- WA Y
SCTM DISTRICT 1000 SECTION 122 BLOCK 2 P/O LOT 23.1
L-
NELSON & POPE,POPE, L-P
ENGINEERS 0 EDEE-SIC'mNEE-FtO 0 SURVEYORS
6p572
WALT WHITMAN ROAD, MELVILLE, N.Y. 11747-2188
(631) 427-5665 FAX (631) 427-5620
THE (OR DIMF�NSIONS)SHOWN
FOUNDATION LOCATION OF LOT 16 HEREONOFFSETS FROM THE STIIUCTUREB TO
THE PROPERTY LINES AM FOR A
PURPOSE AM USE AM
"COTTAGES AT MAT-nTUCK" THB13-OM AM NOT INTENDEDTO
MAP OF GUIDE THE ERECTION Or FENCES.
RETAINING WALLA POOLSPATIOS,
RANTING AREAS,ADDITIONS 70
FILED 0A M. BUILDINGS AND ANY OTHER
CONSTRUCT"L
GUAPANrEES fADIOATED HEREON 84ALL RUN
SrrUATED AT MATTITUCK TO THE PERSON FOR Wl-IOMTHE SURMY 8
PREPARED.NO ON HIS BEHALF TO THE rn-E
COMPANY,OOVSH*NTAL AQENCY AM UREM
TOWN OF SOUTHOLD,IIVFFOI'Vyt'-Q*'TYI':-�IW YORK INSTITUTION LISTED HERE-OR ANDTO THE
w ASBKINEES OF THE LEMINO mmiurnok
0114RANIMES ARE NOT TRANSFERABLE TO
CERTIFIED ONLY TO l OWNER&
ADDITIONAL fMnJTIONS OR SUBSEOUENT
tA 4 !�
UNAUTHORGM ALTERATION OR
DATES : ADDrnON TO THIS SURVEY 19 A
NEW YM STATE EDUCATM LAW.
VIOLATION Or SECTION 7M Or THE
H D P P Loo 7/24/07 SCALE: 1 30' COPIES or THE THIS aim MAP NOT
BEARING LAND SURVEYORS 14M
BEAL OR
B P P P-FINAL JOB No. 02007 EEC
CONSEMBOSSEID Mg.SHALL NOT
IDERED TO BE A VALID TRUE COPY.
NO PHYSICAL EASEMENTS ON PROPERTY
UNIESSNOTED RECORDEDEASEMENTOOR
SO. MEASUREMENTS TO FOUNDATION FILE NO. 1000-112-1 FIC*ff Of:WAYS,IF AW NOT SHOW ARE
UR STANDARD OF MEASUREMENTSNOT CIE .
fi.L0j45
LAND NOW OR FORMERL Y OF
SULLIVAN
(WELL/PRIVATE SANITARY)
i
i
" r 63.52'
h
1 —
LOP 1'6 \ --
AREA=,$;00PIN
0
25' NON7 Dl9f RBED VEGETATE BUFFER '
---- L51 T,n O L ICI I N GEl, c
MROG e00 RUCTION ea
N +(26.6) i :H x �' no
r'
(27.9) I sb7
M I CELLAR + c6 &� �_ J
04 ENT. Cud �"
LOT 15 LOT 17, G b7
17
n
\\(VACANT) � � 30°—O (VACANT > '; p
Z Y3
._- • ° � ; � , PROPOSED
�.' �,. RESIDENCE '
. d ?
O (FFL=29.7) U
+ I 6�
(BFL=22.0) 0 0 0cq
�
00
\ti" 7' A" LOCATIO �TiE•T 1 L #3 ° 2; C '
COV, C' Ehi 13
Ca i c6 PORCH ETA _ rTj �'• h
60 find +I
Cif e11 b i i 'f d gj I
LTJ > 0
2+•6 "Inn y 8' MIN' EJ(PI O er9
?sJ y0�N 5 M�� M1N• J MIN. 1 N ® p��
0 MIN. L.P. 2 . vi I T.' v'.
0i PROP. ORIVE�, 3;I �
w n= 4.4% ¢ CO t`
+ ) o O�
N 17'21'04' W 27 R= ,
TC 25 38.42' L.- 60• 0'
PROP. CONIC, CUR + `6 = v O
26� (P 26.3) 9 T r� ° ^667.4�7 (�O
PROPOSEp WATER k n
TEST HOLE No. 3
DATED 3-30-06 CO��� �� ��
EL. 28,5
TOP SOIL
(PT) LLLJJJ LLL II
LOAM F 1 .,
(OL)
—2 3y
NOTE,• NO WELLS WITHIN 150' OF SUBJECT PROPERTY. -
FINE SAND(Sp) OWNER/APPL/CANT
MINIMUM SEPTIC TANK CAPACITIES LEACHING POOL ISLAND ESTATES EAST
NUMBER OF MINIMUM TANK EFFECTIVE DEPTH 175 PINELAWN ROAD
BEDROOMS CAPACITIES
(GALLONS) 2100 MIDDLE COUNTRY ROAD
-22.0 ELEV 6.5 1,2,3 OR a 1,000 12' SUITE 100
l,,� MEL 19LLE, NY, 11747
BCTM DISTRICT 1000 SECTION 122 BLOCK 2 P/O LOT 23.1 3 i'")�
NELSON & POPE, LLP
ENGINEERS • DESIGNERS • SURVEYORS
572 WALT WHITMAN ROAD, MELVILLE, N.Y. 11747-2188
- (631) 427-5665 FAX (631) 427-5620
LOT 16 THE N'��D (OR DONS)SHOWN
R PLOT PLAN FO NEON FROM THE BTRUOTURES TO
THE PROPERTY I ARE FOR A
BPECM PURIPOSE AM USE AM
MAP OF "COTTAGES AT MATTITUCK" THEREIzORIE AM NCIT INTENDW TO
RETAMIO WALLS,POOL.B,PATIOS.
PLANTINCII AREAS,FILED BUILDNioB AM ANY OTIH0N8rER TO
SITUATED AT M ATTI TU CK GUARANTEES�,„ R
" •�� `"�, �••' �.�• :, �ANY,'OO�VE TAL ON M�AXB=MAD L� J�
TOWN OF SOU TH OL ,s UFF• L. COI`1 1`I' NEW YOR K INSTITUTION LISTEID NEON,AID To TIE
GUARANTEES AM N0T 7RANSF002LE TO
CERTIFIED ONLY TO E >;�:'`-';;'r ADDITIONAL I18I IVTK B OR SUBSEOUENT
oWrrEI:Ia
UNAU HOFUM ALTERATM OR
DATES :
t�" L VK BE M 7M of THE
Y�' {"o r NEW YOW STATE EDUCATION LAW.
H D P P 12 12 06 LOC �� ` SCALE: 1 ' - 30 COPS OF THIS SURVEY MAP NOT
BEARINCI THE LAM BEAL.OR EL*MeeM SEAL S SHALL NOT
B P P P 12 12 06 ANAL �Lti°� � JOB NO. 02007 BE TO 13E A VALID TM COPY,
No PHYSICAL EASEMENTS ON PROPERTY
°�sO. R LE NO. 1000-112-1 IF B
,� re
9
DECLARATION OF COVENANTS AND RESTRICTIONS
DECLARATION, made the &r day of December, 2006, by CDCLI Housing
Development Fund Corporation, having an office at 2100 Middle Country Road,
Centereach,New York 11720, hereinafter referred to as the Declarant.
WHEREAS, the Declarant is the owner of certain real property situate at 895
Factory Avenue, Mattituck, Town of Southold, County of Suffolk and State of
New York, more fully described in Schedule A annexed hereto, and
WHEREAS, the Declarant has made application to the Planning Board of the
Town of Southold for approval of a 22 lot Standard Subdivision in the Affordable
Housing District known as "Cottages at Mattituck", and
WHEREAS, in consideration of the granting of subdivision approval, the
Planning Board of the Town of Southold has required certain covenants as a condition of
said approval and that this Declaration be recorded in the Suffolk County Clerk's Office,
and
WHEREAS, the Declarant has considered the foregoing and determined that the
same will be for the best interest of the Declarant and subsequent owners of said parcels.
NOW, THEREFORE, THIS DECLARATION WITNESSETH:
That the Declarant, for the purposes of carrying out the intentions above
expressed, does hereby covenant and agree that the said premises described in Schedule
"A" annexed hereto shall hereafter be subject to the following-covenants which shall run
with the land and shall be binding upon all purchasers and holders of said premises,their
heirs, executors, legal representatives, distributees, successors and assigns, to wit:
1. No Further Subdivision. There shall be no further subdivision of any lot in
perpetuity.
2. No Lot Line Change. There shall be no modification of any lot line without
the approval of the Planning Board.
3. Non-Disturbance Buffer. The lots shall contain a non-disturbance vegetation
1
buffer at the rear of each lot as shown on the filed map and as set forth below(the Buffer
Area):
Lot 1: 25 feet, and in addition, the northerly area of Lot 1
as shown on the filed map.
Lots 2 through 5 inclusive: 25 feet.
Lot 6: 15 feet
Lot 7: 15 feet in the area shown on the filed map.
Lot 10: 20 feet
Lot 12: 25 feet in the area shown on the filed map.
Lots 13 through 22, inclusive: 25 feet.
No trees or natural vegetative cover may be removed within the Buffer Area;
except for the removal of noxious, dead and decayed vegetation; provided that the area in
which maintenance activity is conducted will be re-vegetated in accordance with a plan
approved by the Planning Board with species native to Long Island and the State of New
York. Such clearing and replanting shall be subject to prior review by the Town Planning
Board to insure the proper maintenance and preservation of the natural buffer. Noxious
vegetation shall mean poison ivy or other poisonous plant material, bamboo, or vines or
other invasive species which threaten the health of trees or other natural undergrowth
within the buffer. No structures may be erected within the Buffer Area, except 1) a
fence around the outer perimeter, and 2) an unlit sign within the Buffer Area of Lot 1
setting forth the name of the subdivision, all of which shall be in compliance with Town
Code. No dumping of debris or other action inconsistent with the non-disturbance
purpose of the Buffer Area is permitted in the Buffer Area.
4. Perpetual Affordability. The subdivision is subject to a Declaration of
Covenants and Restrictions dated November 17, 2006, and recorded in the Suffolk
County Clerk's Office in Liber 12480 cp 627, covenanting, inter alia,that all the lots in
2
such subdivision are subject to the provisions of the Affordable Housing District as set
forth in the Southold Town Code,
5. All structures with impervious areas shall control and retain surface runoff
through the use of gutters, leaders and subsurface drywells.
6. Driveway Access. There shall be no driveway or other vehicular access from
Lot 9 to Factory Avenue. Vehicular access to all lots shall be from Sound Avenue only,
except for emergency access over the access designated on the filed map.
7. These covenants and restrictions can be modified only at the request of the
then owner of the lot with the approval of a majority plus one of the Planning Board of
the Town of Southold after a public hearing. Property owners of other lots in the
subdivision which adjoin or are across the street from the lot subject to the modification
request shall be entitled to notice of such public hearing but their consent to such
modification shall not be required.
IN WITNESS WHEREOF,the Declarant above named has executed the
foregoing Declaration the day and year first above written.
CDCLI Housing Development Fund Corporation
COUNTY CLERK'S OFFICE
STATE OF NEW YORK SS.:
COUNTY OF SUFFOLK
I, JUDITH A. PASCALE, Clerk of the County of Suffolk and the Court
of Record thereof, do,-h<�reby certify that I have compared the annexed with the
original J..............
...� -..........RECORDED in the office on
under LIBER Ia. : ...............PAGE A YI....and, that the same is a true
copy thereof, and of the whole of such original.
In Testimony Whereof, I have hereunto set my hand and affixed the seal of
said County and Court on this ..:l.�r......day of -..............1 20. b
CLERK.. ... e
�... ...................
TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST
BUILDING DEPARTMENT ' Do you have or need the following,before applying?
TOWN HALL Board of Health
SOUTHOLD,NY 11971 4 sets of Building Plans
TEL: (631) 765-1802 Planning Board approval
FAX: (631) 765-9502 330
! Survey V/
✓www. northfork.net/Southold/ PERMIT NO. 3 01� e l Check-V
Septic Form
N.Y.S.D.E.C.
Trustees
Examined 2QV Contact:
Approved ,200V Mail to:
Disapproved a/c
Phone:
Expiration t( 120 d
Building Inspector
APR 5
APPLICATION FOR BUILDING PERMIT
Date (� , 20p
INSTRUCTIONS
a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4
sets of plans, accurate plot plan to scale.Fee according to schedule.
b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or
areas, and waterways.
c.The work covered by this application may not be commenced before issuance of Building Permit.
d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit
shall be kept on the premises available for inspection throughout the work.
e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector
issues a Certificate of Occupancy.
f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the
property have been enacted in the interim, the Building Inspector may authorize, in writing,the extension of the permit for an
addition six months. Thereafter, a new permit shall be required.
APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or
Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described.The
applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations, and to admit
authorized inspectors on premises and in building for necessary inspections.
q
(Si ature of applicant or name,i a corporation)
(Mailing address of applicant)
State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder
Name of owner of premises
(As on the tax roll or latest deed)
If applicant is a corporation, signature of duly authorized officer
(Name and title of corporate officer)
Builders License No.
Plumbers License No.
Electricians License No.
Other Trade's License No.
1. Location of land on w ich roposed work will be done:
650
House Number Streee I Hamlet
�3-!7
County Tax Map o. 1000 Section C Block 0 Lot
Subdivision L Filed Map No. Lot
Name
2. State existing use and occupancy of premises and intended use and occupancy of proposed construction:
a. Existing use and occupancy
b. Intended use and occupancy Kxu) �Q� C�-
3. Nature of work(check which applicable): New Building )0 Addition Alteration
Repair Removal Demolition Other Work
(Description)
4. Estimated Cost Fee
(To be paid on filing this application)
5. If dwelling, number of dwelling units I Number of dwelling units on each floor
If garage, number of cars f
6. If business, commercial or mixed occupancy, specify nature and extent of each type of use.
7. Dimensions of existing structures, if any: Front Rear Depth
Height Number of Stories
Dimensions of same structure with alterations or additions: Front Rear
Depth Height Number of Stories
8. Dimensions of entire new construction: Front �JD I Rear a, Depth
Height IF5 Number of Stories I
9. Size of lot: Front Rear Depth
10. Date of Purchase Name of Former Owner
11. Zone or use district in which premises are situated
12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO SG
13. Will lot be re-graded? YES NO Will excess fill be removed from premises? YES NO �c
14. Names of Owner of remises A Address Phone No.
Name of Architect Address Phone No3- I a�
Name of Contractor 1 Address Phone No.
15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO
* IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED.
b. Is this property within 300 feet of a tidal wetland? * YES NO�
* IF YES, D.E.C. PERMITS MAY BE REQUIRED.
16. Provide survey, to scale, with accurate foundation plan and distances to property lines.
17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey.
STATE OF NEW YORK)
_��5:
COUNTY OF-� �1
C'=:��-r being duly sworn, deposes and says that(s)he is the applicant
(Name of individual signing contract) above named,
(S)He is the Uv— P
(Contractor, Agent, Corporate Officer, etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;
that all statements contained in this application are true to the best of his knowledge and belief, and that the work will be
performed in the manner set forth in the application filed therewith.
Swo4rdayof
re me this
/ aAeh 20 07
K uaI
Notary Public Signature of Applicant
JANEAN.R.VOLLARO
Nolary Public,State of New York
140.01VO6157197
Qu 110 In Suffolk County
GoeffdWon DO=Dom 4,2010
Erosion, Sedimentation and Storm-water Run-off Control Plan ASSESSMENT FORM
Yes. No.
EXEMPTIONS:. —
A. Does.this project meet the.minimum standards for classification as.an Agricultural Project.
Note: If you.answered.Yes.to any of the.above,a Storm-water,Grading,.Drainage.&Erosion.Control.Plan is not required.
-------------------------------------------------------------------
ACTIONS.REQUIRING THE.SUBMISSION OF A STORM-WATER, GRADING,DRAINAGE &EROSION.
CONTROL.PLAN.CERTIFIED.BY A DESIGN.PROFESSIONAL.IN.THE.STATE.OF NEW YORK..
Item Number:. (A Check Mark (J).for each question is.required for complete.application) Yes. No.
1. Will this.project retain all Storm-Water.Run-off generated on Site?
(This:will include all run-off created by site clearing and/or construction activities.as.well as.all —
Site.Improvements.and thee permanent creation of impervious.surfaces.)
2. Wilt this.project require any land filling, grading or excavation where there is,a change to the
natural existing grade involving more than 200.cubic yards.of material within any.parcel?
3.. Will this application require.land disturbing activities.encompassing an area.
of five.thousand(5,000)square feet of ground surface or.more?
4. Is.there.a Natural Water course.running through the.site or is.this project within
One hundred(100).feet of wetlands or a beach? ❑
5. Will there be site,preparation on slopes which exceed fifteen(15)feet of vertical rise.to.
One.hundred(100),feet of horizontal distance? ❑
6.. Will driveways,.parking areas or other impervious.surfaces.direct Storm-Water.Run-off.
into and/or in the.direction of a Town Right-of-Way?
7. Will this application require the placement of material,removal of vegetation and/or the
construction of any item within the Town Right-of-Way or road shoulder area?
(This.item.does not include the installation.of driveway aprons.)
8. Will there be.site.preparation within the one hundred(100).year floodplain of any.watercourse?
Note: If any answer to.questions one.through.eight is.answered.with,a check mark in the.Box,a Storm-water,Grading,
Drainage.&Erosion.Control.Plan is.required and must be.submitted for review prior to.issuance.of any building.permit.
-------------------------------------------------------------------
STATE OF NEW YORK,
C UNTYOF........ PP
,.. ...�................. ss
That I, ..... ... .«.�...1��0.!"`�...........................being duly sworn,deposes and says that he/she is the applicant for Permit,
(Name of individual signing Document)
Andthat He/She is the ............f..!. .... . ...............................................................................................................................
�`✓✓ (Owner,Contractor,Agent,Corporate Officer,etc.)
Owner and/or representative of the Owner or Owner's,and is duly authorized to perform or have performed.the said work and to make
and file this application;that all statements contained in this application are true to the best of his knowledge and belier;and that the
work sill be performed in the manner set forth in the application filed herewith.
Sworn to before me this;
.. .. ...... ...........day own
.I......................20..0�
: � .
Notary Public: .. ................... )7 C_;C:ne�--6
.......Jr.........JMF. I:�
R-'V0 IRO ...e
Notm pub,State of New York Signature of Applicant)
NO.OIVOSI57197
Conmied In Suffolk w—, 4n,y
Comrnissfon E�Ires Dec.4,W0
RES check Software Version 4.0.1
Compliance Certificate
Project Title: COTTAGES @ MATTITUCK 05.236
Report Date: 06/07/07
Data filename: F:IMEC AND RES CHK PROJECTSI05 Projectsl05.236 COTTAGE @MATTITUCK.rck
Energy Code:
New York State Energy Conservation
Construction Code
Suffolk County, New York
Detached 1 or 2 Family
Non-Electric
14%
5750
Location:
Construction Type:
Heating Type:
Glazing Area Percentage:
Heating Degree Days:
Construction Site:
Owner/Agent:
Designer/Contractor:
GARY CANNELLA ASSOCIATES
55 KNICKERBOCKER AVE.
BOHEMIA, NY 11716
Compliance Passes MaXimum Uk 250 Your Home UA 248 -> 0.8% Belter Than Code (UA)
Gross Cavity Cont. Glazing UA
Assembly Area or R.Value R-Value or Door
Perimeter U-Factor
Ceiling 1: Flat Ceiling or Scissor Truss:
Wall 1 : Wood Frame, 16" a.c.:
Window 1: Vinyl Frame:Double Pane with Low-E:
Door 1: Solid:
Door 2: Glass:
Floor 1: All-Wood JoistITruss:Ov rUn
The proposed building repr
with this permit applicatio
Code requirements. W
his/her knowledge. b
1100
1278
145
20
40
1100
30.0
13.0
19.0
0.0 39
0.0 88
0.340 49
0.290 6
0.340 14
0.0 52
he building plans, specifications, and other calculations submitted
aa d Ign to meet the New York State Energy Conservation Construction
sta ped and signed this page, they are attesting that to the best of
a s or pecifications are in compliance with this Code.
-;
Date
---- .
(
,
-~,
. ---- It_ \.... \ \
".-, . \
\
\
.--.-'
"
j\)~ \ \
J
.~
~'
......-
----
.-----
\---->
COTTAGES @ MATTITUCK 05.236
Page 1 of 4
REScheck Software Version 4.0.1
Inspection Checklist
Date: 06/07/07
Ceilings:
o Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
Above-Grade Walls:
o Wall 1 : Wood Frame, 16" a.c., R-13.0 cavity insulation
Comments:
Windows:
o Window 1: Vinyl Frame:Double Pane with Low-E, U-factor: 0.340
For windows without labeled U-factors, describe features:
#Panes _ Frame Type
Comments:
Thermal Break? _ Yes _ No
Doors:
o Door 1: Solid, U-factor: 0.290
Comments:
o Door 2: Glass, U-factor: 0.340
Comments:
Floors:
o Floor 1: All-Wood JoistfTruss:Over Unconditioned Space, R-19.0 cavity insulation
Comments:
Air Leakage:
o Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed.
o Recessed lights are 1) Type Ie rated, or 2) installed inside an appropriate air-tight assembly with a 0.5" clearance from
combustible materials. If non-Ie rated, fixtures are installed with a 3" clearance from insulation.
Vapor Retarder:
o Installed on the warm-in-winter side of all non-vented framed ceilings, walls, and floors.
Materials Identification:
o Materials and equipment are installed in accordance with the manufacturer's installation instructions.
o Materials and equipment are identified so that compliance can be determined.
o Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided.
o Insulation R-values and glazing V-factors are clearly marked on the building plans or specifications.
o Insulation is installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a
manner that achieves the rated R-value without compressing the insulation.
Duct Insulation:
o Supply ducts in unconditioned attics or outside the building are insulated to R-8.
o Return ducts in unconditioned attics or outside the building are insulated to RA.
o Supply ducts in unconditioned spaces are insulated to R-8.
o Return ducts in unconditioned spaces (except basements) are insulated to R-2. Insulation is not required on return ducts in
basements.
COTTAGES @ MATTITUCK 05.236
Page 2 of 4
Duct Construction:
o All joints, seams, and connections are securely fastened with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric,
or tapes. Tapes and mastics are rated UL 181A or UL 1818.
Exceptions:
Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pal.
o The HVAC system provides a means for balancing air and water systems.
Temperature Controls:
o Each dwelling unit has at least one thermostat capable of automatically adjusting the space temperature set point of the largest
zone.
Electric Systems:
o Separate electric meters exist for each dwelling unit.
Fireplaces:
o Fireplaces are installed with tight fitting non-combustible fireplace doors.
o Fireplaces have a source of combustion air, as required by the Fireplace construction provisions of the Building Code of New York
State, the Residential Code of New York State or the New York City Bui/ding Code, as applicable.
Service Water Heating:
o Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat
trap or is part of a circulating system.
o Circulating hot water pipes are insulated to the levels in Table 1.
Circulating Hot Water Systems:
o Circulating hot water pipes are insulated to the levels in Table 1.
Swimming Pools:
o All heated swimming pools have an on/off heater switch and a cover unless over 20% of the heating energy is from non-depletable
sources. Pool pumps have a time clock.
Heating and Cooling Piping Insulation:
o HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2.
COTTAGES @ MATTITUCK 05.236
Page 3 of 4
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes
Heated Water
Temperature (OF)
170-180
140-169
100-139
Insulation Thickness in Inches by Pipe Sizes
Non-Circulating Runouts Circulating Mains and Runouts
Up to 1" Up to 1.25" 1.5" to 2.0" Over 2"
Q5 1~ 1B 2~
0.5 0.5 1.0 1.5
0.5 0.5 0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes
Piping System Types
Heating Systems
Low PressurelTemperature
Low Temperature
Steam Condensate (for feed water)
Cooling Systems
Chilled Water, Refrigerant and
Brine
Fluid Temp.
Range(OF)
Insulation Thickness in Inches by Pipe Sizes
2" Runouts 1" and Less 1.25" to 2.0" 2.5" to 4"
40-55
Below 40
1.0 1.5 1.5 2.0
0.5 1.0 1.0 1.5
1.0 1.0 1.5 2.0
0.5 0.5 0.75 1.0
1.0 1.0 1.5 1.5
201-250
120-200
Any
NOTES TO FIELD: (Building Department Use Only)
COTTAGES @ MATTITUCK 05.236
Page 4 of 4
N69052 O"E
ON FOUND MON FOUND
~ 2n.87' ,: ~.
i ------~--71
....~r LOT 22 / 1.75'
~ L 13,657 sq.ft. " /
11\ Q.31acres,/ J
I __ _~'___
~f.=J:t..,o;.AL
S690~2'20.W ..' 214.38'
w _
~r:.::-~"-'L~T2-;- ./-7
- ;,1 l1,135sq.ft.R' /
ihL _ _O.~a~s_..../
S690S2'20~W
160.63'
----,
~r LOT2a ...,
. I 8,911 sq.~. 1111
... 0.20 acres .
L___--I
569052'20.W
141.31'
,------, :;:
I LOT 19 I ".
8,.444 sq.ft. i "! S
L-~1:...~~ &n~
569052'20.W PROPOSe
140.48' ..
~:r.- - - - ---,~
o Lar18~ >< 8it
~~ 8J39' sq.~. I / g ~ ..
I ~ u.19 acres --,. ~
~"'L___. &.
. 569052'20.W "
139.35' ItS3' z
r 70.;7, - ., (ff.. "
8,181 sq.ft. J oQ,": C1
L~l~~ j"
S69052'20"W
128.80'
0
~
0
v.
. n
"'OJ
O'
00
OM
N
Z
z
..
>
:;
~
::>
'"
> ~
<< 0
~ >
~ ~
~ <<
w
'~ :E
if <<
:> 0
ill ~
"
<<
0
"
0
z
"
z
..
~
N71009'30"E 177.27'
'OUND
&T.H.
'0"0'
RECHARGE BASIN
49,203 sq.ft.
1.13 acre.
TO BE DEDICATED TO THE
TOWN OF SOUTHOLD
z'
:l~
:J
m
::>
.
z
:l
r-
o
o
o
o
o
,
,
,
,
o
.-
\j--1
;;;
;...
o
o
o
N
Ul
>-u
cd~
05
l::i~
<{-
u..
150'
235.62'
C3
'"
21.24
r ~T~ 'l
I 8,001 sq.~. ,
0.18 acres
L__-l
.,
GO
.~
iii. <0
{o, ~
00",'
9~ :<I-
0",
>r
~5
~=
~
W~
w
CJ~
.<(~
.I-~
;0 1-i3
~ O€ i:J
Co ~ U~ :8i8
P'I.... G)"""ai
/ ~;;: ~ <0
~~
O!:(
~;o
zu
:lii!
::>
, ..
N69052''';'''E
:" 38.0pfV
o
ISO'
C3
c,""
'-
\~~~
,
g
ci
:::'"
~
"
S700SS'20.W
133.28' /
r---.,
LOT 2 ~
I 8"204 sq.~. I
u.19 acres -
L___....J.
S70oS5'20.W W
138.36'
RE,'IA1NSOf
r - ~~E~~
I LOT]"" I
8,33' sq.~., / .
~.~~"_ -.J ~
LAND NOW OR fORMERLY OF rI
AYTUUN L.-r--J
C3
r;;;:;.;;, /
~ I 8,000 sq.~. a .
" 0.18 acres Jf.H. N
f L _ _ -1#3 m N
U; S70028'04.W ~
123.22' ~
: r-;:-OT~I "
~ I 8,000 sq'~'1 ::l
..; 0.18 acres '"
"L _..J;
I5'MIN.
2S'MIft.TCIt.....
2
/
,
,
PUBUC WATER/PRIVATE SANITARY/NO WELLS
'So.
MON FOUND
ii>O
~ NO NOW OR fORMERlY 0
- OIAZ
~ WELl/PRIVATE SANITARY
..
"
139. /
t LOT4 -:- -,~
8,401 'q.~. I~
0.19 acres i J
R --- ~I
S70oS5'20.W
144.20'
r - - --/-,
lOT 5 v'
L 9,117 sq.tt. &.
0.21 acres ."
---_-l
S70055'2~.W MON
NO OW OR FORMER.[
ZANESkl
~.~t4EFOU WEu'/PRlVATE SANITARY
!U
o
n
.'"
'n
~
'n
'Ul
LANONOWORFORMERLYOF 0
MCGETRICK
PUBUC WATER/PRIVATE SANITARY/NO WELLS
~.\Pl'
BUFF,_15,Ol'
JrL;-., j~ .
/8,001 sq'~'1 ~i
0.18 acres 9~
L _ --1 ~lj
S70028'~nw ~
o
LAND NOW OR FORMERLY OF BRADLEY
PUBUC WATER/PRIVATE SANITARY/NO WELLS
o
255.99'
152.45'
BUl'feR~'20.c:l'
w
::>~
2'"
W~
>w
<{~
>-0
o::i!i
05
l::ig
~
011-0
l\..~
~O~
\SV'
\..O~G
PEDESTRIAN AND
EMERGENCY ACCESS
TO BE DEDICATED TO THE
TOWN OF SOUTHOLD
5,988 S.F. .q.ft.
0.14 acre.
...~u.S
,1,,0
""""
~~s>'
yI'S"
....~
vv~v.c.
3 12-19-06 ADD COVENANTS AND RESTRIC
2 11-10-06 ADO ADJACENT BUILDINGS
1 08-25-06 REVISE PER COMMENTS
NO. DATE DESCRIPTION
Date: 04/25107
Transaction(s):
22 22
Town Of Southold
P.O Box 1179
Southold, NY 11971
* * * RECEIPT * * *
Reference
3682-37
Cash
Septic Permit - Construct - Resid.
Total Paid:
Name:
Island, Estates East Lie
175 Pinelawn Road Suite 100
Melville, NY 11747
Clerk ID: BONNIED
Subtotal
$220.00
$220.00
Internal 10: 3682-3703
KENNETH L. EDWARDS
MARTIN H. SIDOR
GEORGE D. SOLOMON
JOSEPH L. TOWNSEND
MAIUNG ADDRESS:
P.O. Box 1179
Southold, NY 11971
OFFICE WCATION:
Town Hall Annex
54375 State Route 25
(cor. Main Rd. & Youngs Ave.)
Southold, NY
PLANNING BOARD MEMBERS
JERILYN B. WOODHOUSE
Chair
r.-:--"--'..'---
(~ ~ (r:1 [1 n ~7
i! U ['.- - ..,._u.'
lu~ 26,
I
Telephone: 631 765-1938
Fax: 631 765-3136
PLANNING BOARD OFFICE
TOWN OF SOUTHOLD
ii
J ..../
,
1"1'.'
MEMORANDUM
To: Building Department
From: Anthony Trezza, Senior Planner
Date: November 26,2007
Re: The Cottages at Mattituck
It has been brought to the Planning Board's attention that the Building Department is
preparing to issue Certificates of Occupancy for a number of residences in the recently
constructed Cottages at Mattituck. Please be advised that the Planning Board has no
objections to the issuance of the CO's because the builder has agreed to complete the
installation of the monuments within 60 days of the date ofthis correspondence. In
addition, the Town will not release the bond until such time as all work is completed.
.
; .
,
Permit #
Permit Date
REScheck Software Version 3.7.3
Compliance Certificate
Project Title: COTTAGES @ MATTITUCK 05.236
Report Date: 12/07/06
Data filename: F:\MEC AND RES CHK PROJECTS\05 Projects\05.236 COTTAGE@ MATTITUCK .rck
Energy Code:
New York State Energy Conservation
Construction Code
Suffolk County, New York
Detached 1 or 2 Family
Non-Electric
14%
5750
Location:
Construction Type:
Heating Type:
Glazing Area Percentage:
Heating Degree Days:
Construction Site:
Owner/Agent:
Designer/Contractor:
GARY CANNELLA ASSOCIATES
55 KNICKERBOCKER AVE.
BOHEMIA, NY 11716
Compliance Passes Maximum UA 250 Your Home UA 248 u> O.8%} Better Than Code (UA)
Assembly
..... .
.: -. o' . . . . .. . . . ~",
Ceiling 1: Flat Ceiling or Scissor Truss:
WaUl: Wood Frame, 16" D.C.:
Window 1: Vinyl Frame:Double Pane with Low-E:
Door 1: Solid:
Door 2: Glass:
Floor 1: All-Wood JoistfTruss:Over Unconditioned Space:
1100
127B
145
20
40
1100
19.0
0.0 39
0.0 BB
0.340 49
0.290 6
0.340 14
0.0 52
30.0
13.0
The proposed building represented in this document is consistent with the building plans, specifications, and other calculations
submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation
Construction Code requirements. When a Registered Design Professional has stamped and signed this page, they are attesting that
to the best of hislher knowledge, belief, and professional judgment, such plans or specifications in Uan ith thi Co e.
Builder/Designer
Company Name
/
COTTAGES @MATTITUCK05.236
Page 1 of4
. .
REScheck Software Version 3.7.3
Inspection Checklist
Date: 12/07/06
Ceilings:
o Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
Above-Grade Walls:
o Wall 1 ; Wood Frame, 16" C.C., R-13.0 cavity insulation
Comments:
Windows:
o Window 1: Vinyl Frame:Double Pane with Low-E, U-factor: 0.340
For windows without labeled U-factors, describe features:
#Panes _ Frame Type Thermal Break? _ Yes _ No
Comments:
Doors:
o Door 1: Solid. U-factor: 0.290
Comments:
o Door 2: Glass, U-factor: 0.340
Comments:
Floors:
o Floor 1: All-Wood JoisVTruss:Over Unconditioned Space, R-19.0 cavity insulation
Comments:
Air Leakage:
o Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed.
o Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air-tight assembly with a 0.5" clearance from
combustible materials. If non-IC rated, the fixture must be installed with a 3" clearance from insulation.
Vapor Retarder:
o Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors.
Materials Identification:
o Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
o Materials and equipment must be identified so that compliance can be determined.
o Manufacturer manuals for all installed heating and cooling equipment and seNics water heating equipment must be provided.
o Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications.
Duct Insulation:
o Supply ducts in unconditioned attics or outside the building must be insulated to R~8.
o Return ducts in unconditioned attics or outside the building must be insulated to R-4.
o Supply ducts in unconditioned spaces must be insulated to R-8.
o Return ducts in unconditioned spaces (except basements) must be insulated to R-
o Return ducts in unconditioned spaces (except basements) must be insulated to R-2.
. Insulation is not required on return ducts in basements.
Duct Construction:
COTTAGES @ MATTITUCK 05.236
Page 2 of 4
. .
o All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives),
mastic-plus-embedded-fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 1818.
Exception: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500
Pal.
o The HV AC system must provide a means for balancing air and water systems.
Temperature Controls:
o Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest
zone.
Electric Systems:
o Separate electric meters are required for each dwelling unit.
Fireplaces:
o Fireplaces must be installed with tight fitting non-combustible fireplace doors.
o Fireplaces must be provided with a source of combustion air, as required by the Fireplace construction provisions of the Building
Code of New York State, the Residential Code of New York State or the New York City Building Code, as applicable.
Service Water Heating:
o Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral
heat trap or is part of a circulating system.
o Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
o Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
o All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from
non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
o HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table
2.
COTTAGES @MATTITUCK05.236
Page 3 of 4
.
. .
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness in Inches by Pipe Sizes
Heated Water
Temperature (OF) Upto 1" Up to 1.25" 1.5" to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-189 0.5 0.5 1.0 1.5
100-139 0.5 0.5 0.5 1.0
Non-Circulating Runouts
Circulating Mains and Runouts
Table 2: Minimum Insulation Thickness for HVAC Pipes
Piping System Types
Heating Systems
Low PressurefT emperature
Low Temperature
Steam Condensate (for feed water)
Cooling Systems
Chilled Water, Refrigerant and
Brine
Fluid Temp.
Range("F)
Insulation Thickness in Inches by Pipe Sizes
2" Runouts 1" and Less 1.25" to 2.0" 2.5" to 4"
1.0 1.5 1.5 2.0
0.5 1.0 1.0 1.5
1.0 1.0 1.5 2.0
0.5 0.5 0.75 1.0
1.0 1.0 1.5 1.5
201-250
120-200
Any
40-55
Below 40
NOTES TO FIELD: (Building Department Use Only)
COTTAGES @ MATTITUCK 05.236
Page 4 of4
Index Page 1 of 1
Permit Number:
Miscellaneous:
Lot Number:
Address:
The information in this box is for administrative purposes only and is not part of the engineering review
Standard Loadina:
T.C. live 30 psf
T.C Dead 7 psI
B,C live 0 psf
Be Dead 8 psf
Total 45 psf
Truss Fabricator:Triangle Building Products
Job Reference:Q608030 - Ranch Roof
ROBBINS 6904 Parke East Blvd Engineering Index Sheet
Tampa. FL 33610-4115
ENGINEERING. INC. Phone: (813) 972-1135 Index Page 1 of 1
Job Number Date Specification Quantity
T07041879 04/20/2007 12
A Professional Engineer's seal affixed to this Index Sheet indicates the acceptance of Professional E~ineering
responsibilities for Individual truss comftonents fabricated in accordance with the listed and attached russ Specification
Sheets. Determination as to the suitabi i~ of these individual truss components for any structure is the resRonsibil~ of the
Building Designer, as defined in ANSJrr r 1-2002, Section 2.2. Permanent files of the original Truss Speclficstion heet are
maintained by Robbins Engineering, Inc. Questions regarding this Index Sheet and/or the attached Specificatton Sheets may
be directed to the truss fabricator listed above or Robbins Engineering, Inc. (Sofware - Online Plus)
ANSI/ASCE 7-02
Wind Speed. 120 MPH
Mean Roof HI. - 25 FT
Exposure Catergory - C
Occupancy Factor - 1.00
MWFRS
Enclosed
Notes: Refer to individual
truss design drawings for
special loading
conditions.
Date Mark
[1~4/20/071 C1 1
C=f---ni4i20/071 G2---1
0-=]24/20/071 T4I
Date Mark
~~~
16 104/20/0~~
i10-------roo~T5-1
Date Mark
Ll'~7071Gn
I 7 104/201071 T2 1
1 11 104/20/071 v--;--j
Date Mark
~Lt2~~1D
1 8 104/2~O
1 12 104/2QIQ'?'L...:-{U
lr~:~S~~ig~fj$~.rer: Thomas A. Alban;
Address: P,O. Box 280055. Tampa, Fl33682
.___nQ;!!E;!! Sealed:~!?_012007____
I Job I
I. Q608030'----_CL
I U#J#Q60863.0 Ranch Roof
I
!
Mark
T
2-11-9
J
-~t-~
Quan
2
Type
VLM. SB
Span
51009
P1-H1
6
DG 6-7-0
HO .
f--~
lx311
D
3x4-;::.
A
I~
E
lx311
/-771/ / /
S-lO~9
5-10-9
---5-10-9---
ALL PLATES ARE LOCK2Q
Left OH
o
Righ t OH i Engineering
o ! T07041879
HO 2-11-9
lx311
F
2x411
B
G C
lx311 2x411
//1
-j
Scale: O_590~ = l'
Online Plus Version 21.0.012
RUN DATE: 4-20-07
Robbins Engineering, Inc./Online Plus'M APPROX. TRUSS WEIGHT, 25.6 LBS
CSI SIZE LUMBER
TOP 0.36 2X 3 SPF-#2
BTM 0.21 2X 3 SPF-#2
WBS 0.11 2X 3 SPF-STUD
REPETITIVE MEMBER INCREASES:
FB 15.0% FT 0.0% FC 0.0%
LATERAL BRACING:
TOP CHORD - CONTINUOUS
BTM CHORD - CONTINUOUS
TRUSS SPACING - 24.0 IN.
STANDARD LOADING
LUMBER STRESS INCREASE: 15.0%
PLATE STRESS INCREASE: 15.0%
LOADING LIVE DEAD (PSF)
TOP CHD 37.8 7.0
BTH CHD 0.0 8.0
TOTAL 37.8 15.0 52.8
SUPPORT CRITERIA
CONTINUOUS BETWEEN JNTS A & C
LEFT RIGHT
GIRD DIN - 4SX
MEMBR CSI P(LBS) M@lST M@2ND
TOP CHORDS
A-D 0.36 171 C -532 855
D-F 0.34 53 C -855 67
F-B 0.02 10 C -67 5
BOTTOM CHORDS
A-E 0.21 0 T -576 -194
E-G 0.07 0 T 194 78
G-C 0.03 0 T -78 0
WEBS
E-D 283 C G-F 86 T
CoB 22 C
DL+LL DEFL = 0.04ft IN A-D
LL DEFL < BRG-SPAN/240
SPAN/DEFL (DL+LL) = 999
PLATING CONFORMS TO TPI.
PLATE VALUES MAY BE VERIFIED
WITH ROBBINS MANUFACTURING.
GRIP BASED ON SPF & SYP LUMBER
USING GROSS AREA TEST.
PLATES - 20 GAUGE LOCK
GRIPPING 514-250 PSI PER PAIR
INCLUDES 15.0% INCREASE
TENSION 1339- 465 PLI PER PAIR
SHEAR 784- 506 PLI PER PAIR
JT TYPE PLATE SIZE X Y
A 2003 3.00 X 4.00 4.0 2.5
B 4200 2.00 X 4.00 CTR CTR
C 4000 2.00 X 4.00 CTR CTR
D 1001 1. 00 X 3.00 1.6 0.4
E 1001 1. 00 X 3.00 CTR CTR
F 1001 1. 00 X 3.00 1.5 0.5
G 1001 1. 00 X 3.00 CTR CTR
REVIEWED BY:
Robbins Engineering, Inc.
6904 Parke East Blvd.
Tampa, FL 33610
REFER TO ROBBINS ENG. GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
1. TRUSSES MANUFACTURED BY
TRIANGLE BUILDING PRODUCT
2. EMPIRICAL ANALOG IS USED.
3. WIND LOADS - ANSI/ASCE 7-02
TRUSS IS DESIGNED AS A
MAIN WIND-PORCE RES SYSTEM
FOR EXTERIOR ZONE LOCATION
WIND SPEED - 120 MPH
MEAN ROOF HEIGHT - 25'
EXPOSURE CATEGORY - C
OCCUPANCY FACTOR - 1.00
ENCLOSED BUILDING.
TC DEAD LOAD = 4.0 PSP
BC DEAD LOAD = 5.0 PSF
4. ROOF SNOW LOAD PER ASeE 7-02
GROUND SNOW LOAD = 45.0 PSF
RAIN LOAD NOT REQ'D
IMPORTANCE FACTOR: 1.00
RObb,ns Eng,neenng. InclOnline PillS'" ~ 1996-2007 VersIOn 210.012 Engoneering. Port'3Il 412012007 230c46 PM Page 1
THERMAL FACTOR: 1.00
EXPOSURE FACTOR: 1.20
(BALANCED FACTOR =0.84
UNBALANCED NOT REQ'D)
5. LIVE LOAD CHECK PER BOCA-96,
SECTION 1606.2.3
6. ANCHOR TRUSS FOR A TOTAL
HORIZONTAL LOAD OF 208 LBS.
7. FASTEN TRUSS TO BRG E
POR 287 LBS OP UPLIFT,
WHILE PERMITTING NO UPWARD
MOVEMENT OF WALL OR BRG.
8. FASTEN TRUSS TO BRG G
FOR 62 LBS OF UPLIFT,
WHILE PERMITTING NO UPWARD
MOVEMENT OF WALL OR BRG.
Truss Design Engineer: Thomas A. Albani
LIcense #: 077357-1
Address: P.O. Box 280055, Tampa, FL 33682
Dale Sealed: 4/20/2007
,--
I
Job
Mark
C2
Q608030
U# J#Q608030
Ranch Roof
l____
2x4i1
r///L/7:
j
Quan
2
Span
30209
Pl-Hl
6
Type
VLM. S8
DG 3-7-4
HO 4
'I
I
I
1-7-9
1
igt-
l-E1--~.
3-2-9
3-2-9
3-2-9
ALL PLATES ARE LOCK20
Robbins Engineering. Inc . (Online Plus'. APPROX. TRUSS
Online Plus -- Version 21.0.012 PLATING CONFORMS TO TPI.
RUN DATE: 4-20-07 PLATE VALUES MAY BE VERIFIED
WITH ROBBINS MANUFACTURING.
GRIP BASED ON SPF & gyp LUMBER
USING GROSS AREA TEST.
PLATES - 20 GAUGE LOCK
GRIPPING 514-250 PSI PER PAIR
INCLUDES 15.0% INCREASE
TENSION 1339- 465 PLI PER PAIR
SHEAR 784- 506 PLI PER PAIR
CSt SIZE LUMBER
TOP 0.36 2X 3 SPF-#2
BTM 0.25 2X 3 SPF-#2
WES 0.05 2X 3 SPF-STUD
REPETITIVE MEMBER INCREASES:
FB 15.0% PT 0.0% FC 0.0%
LATERAL BRACING:
TOP CHORD - CONTINUOUS JT TYPE PLATE SIZE X Y
BTMCHORD - CONTINUOUS A 2003 3.00 X 4.00 4.0 2.5
TRUSS SPACING - 24.0 IN. B 4200 2.00 X 4.00 CTR CTR
C 4000 2.00 X 4.00 CTR CTR
STANDARD LOADING
LUMBER STRESS INCREASE: 15.0%
PLATE STRESS INCREASE: 15.0%
LOADING LIVE DEAD (PSF)
TOP CHD 37.8 7.0
BTM CHD 0.0 8.0
TOTAL 37.8 15.0
SUPPORT CRITERIA
CONTINUOUS BETWEEN JNTS A ,C
52.8
GIRD
LEFT
DIN 4SX
RIGHT
MEMBR
CSI P(LBS) M@IST
TOP CHORDS
0.36 54 C -624
BOTTOM CHORDS
0.25 0 T -676
WEBS
131 C
M@2ND
A-B
A-C
COB
DL+LL DEFL = 0.05" IN A-B
LL DEPL < BRG-SPAN/240
SPAN/DEFL (DL+LL) = 744
REVIEWED BY:
Robbins Engineering, Inc.
6904 Parke East Blvd.
Tampa. FL 33610
5
REFER TO ROBBINS ENG. GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
1. TRUSSES MANUFACTURED BY
TRIANGLE BUILDING PRODUCT
2. EMPIRICAL ANALOG IS USED.
3. WIND LOADS - ANSI/ASeE 7-02
TRUSS IS DESIGNED AS A
MAIN WIND-FORCE RES SYSTEM
POR EXTERIOR ZONE LOCATION
WIND SPEED - 120 MPH
MEAN ROOF HEIGHT - 25'
EXPOSURE CATEGORY - C
OCCUPANCY FACTOR - 1.00
ENCLOSED BUILDING.
TC DEAD LOAD =
BC DEAD LOAD =
4. ROOF SNOW LOAD PER
o
4.0
5.0
ASCE
Robbins EngIneering, Inc /Online Plus""@ 1996-2007 Version 21.0.012 En.gineenng. Porlrall 41'201'200723045 PM Page 1
~~~;:~1'~";9 -1
I
Left OH
o
Right OH
o
2lC.4ii
HO
Scale: 0.816"::: l'
10.7 LBS
GROUND SNOW LOAD = 45.0 PSF
RAIN LOAD NOT REQID
IMPORTANCE FACTOR: 1.00
THERMAL FACTOR: 1.00
EXPOSURE FACTOR: 1.20
(BALANCED FACTOR =0.84
UNBALANCED NOT REQ'D)
5. LIVE LOAD CHECK PER BOCA-96,
SECTION 1606.2.3
6. ANCHOR TRUSS FOR A TOTAL
HORIZONTAL LOAD OF 107 LBS.
7. FASTEN TRUSS TO BRG A
FOR 81 LBS OF UPLIFT,
WHILE PERMITTING NO UPWARD
MOVEMENT OF WALL OR BRG.
8. FASTEN TRUSS TO BRG C
FOR 137 LBS OF UPLIFT,
WHILE PERMITTING NO UPWARD
MOVEMENT OF WALL OR BRG.
WEIGHT:
Truss Design Engineer: Thomas A. Albani
LIcense #: 077357-1
Address: P.O. Box 280055, Tampa, FL 33682
PSF
PSF
7-02
Date Sealed: 4120/2007
r-- ~-~'-.~-Job --r~ ------ I --- -_nT---~
I Hark I Quan Type Span P1-H1 Left OH Right OH Engineering
LQ608Q,10_ I Gl I 1 TR 380000 6 l- a- 0 1- 0- 0 T07041879
, -------- ~_________u__ ___,_
lt1-# J#Q608030 Ranch Roof
--~ - ~-
This truss is NOT symmetric.
Proper orientation 16 essential.
5x6=
DG 21-4-13 B DG 21-4-13
HO '.3 HO '-3
TT z ee
X EE
3x6-:::. 3x6-:::-
'i-- Sl GG S2
II
10-3~l5 KK
9-10-3 'I MM
11 N U I 00
~ I
L 4x6=
e
M 0 K Q S u W S3 y AA BB DO 1"1" S4 HH JJ LL NN pp RR
*2x411 3x6= 3x6=
Cant:4- 4 ~
W:308
R: 600
U, 234
~
-BCle ~7-4~0
ir7"7777-7-77777/ / / / / / / / / / / / / / / / / / " / , / / / Tr-~T7'/77-TTr777-T/ / / / / / / / TJ"""777l
_:Ll..:ll..:..L_
o
o
o
o
__38~0.f!__'--_.~----f-i
eoi
38-0-0
ALL PLATES ARE LOCK20
See Joint L For Typical Gable Plate Size and Placement
Scale: 0_166" = l'
-.J
38-0-0
Robbins
Online Plus -- Version 21.0.012
RUN DATE, 20-APR-07
Te
Be
GW
eS1
0.64
0.72
0.25
0.23
M -L
U -T
PP-OO
-Size-
2x ,
2x ,
2x 3
2x 3
o -N
JJ-II
RR~OO
2x 4 SPF-STUD
_-uLwnberu--
SPF-#2
SPF-#2
SP1"-#2
S1"F-STUD
K -1" S 4R
LL-KK NN~MM
WG
Brace truss as follows:
O.C. From To
TC Cont. 0- O. 0 38- 0- 0
BC Cont. 0- 0- 0 ]8- 0- 0
we I rows CLB on AA-Z
we 1 rows CLB on BB-B
we 1 rows CLB on DD-CC
Attach CLB with (l)-IOd nails
at each web.
psf-Ld Dead Live
TC 7.0 ]7.8
BC 8.0 0.0
TC+BC 15.0 37.8
Total 52.8 Spacing 24.0n
Lwnber Duration Factor 1.15
Plate Duration Factor 1.15
TC Fb~1.15 1"c=1.l0 Ft=l.lO
BC Fb~1.l0 Fc=l.lO Ft=1.10
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
A 601 2]4 U ]56 R
K 3685 2095 U ]58 R
J'
A
K
Brg Size
].5"
368.0"
Required
1. 5-
88"-to~ 456"
Plus 6 Wind Load Case(s)
Plus 2 Unbalanced Load Cases
Hembr CSI 1" Lbs Axl-CSI-Bnd
----------top Chords----------
A -L 0.47 224 c 0.00 0.47
L -N 0.50 170 C 0.00 0.50
N -1" 0.64 164 T 0.00 0.64
P -R 0.64 268 C 0.00 0.64
R -T 0.08 258 T 0_04 0.04
T -Sl 0.09 346 T 0.05 0.04
Sl-V 0.09 350 T 0.05 0.04
V -X 0.12 4]] T 0.07 0.05
X 4Z 0.13 524 T 0.08 0.05
Z -8 0.14 596 T 0_09 0.05
B -CC 0.14 596 T 0.09 0.05
CC-EE 0.13 524 T 0_08 0.05
EE-GG 0.12 433 T 0.07 0.05
GG-S2 0.09 ]49 T 0.05 0.04
Bngineering, Inc./Online P1us~ APPROX.
S2-I1 0.09 346 T 0.05 0.04
II-KK 0.08 264 T 0.04 0.04
KK~MH 0.08 19] C 0.00 0.08
MH-OO 0.08 192 C 0.00 0.08
OO-QQ 0.14 193 C 0.00 0.14
QQ-C 0.14 218 T 0.00 0.14
--------Bottom Chords---------
A -H 0.64 178 T 0.03 0.61
H -0 0.64 178 T 0.03 0.61
o -K 0.72 178 T 0.03 0_69
K -S 0.72 178 T 0.03 0.69
S ~U 0.12 178 T 0.03 0.09
U -w 0.06 178 T 0.03 0.03
w -S3 0.03 178 T 0.03 0.00
S]*Y 0.0] 178 T 0.0] 0.00
Y -AA 0.04 178 T 0.03 0.01
AA-BB 0.04 178 T 0.03 0.01
BB-DD 0.04 178 T 0.0] 0.01
DD-FF 0.04 178 T 0.0] 0.01
F1"-S4 0.0] 178 T 0.03 0.00
S4-HH 0.03 178 T 0.03 0.00
HH-JJ 0.04 178 T 0.0] 0_01
JJ-LL 0.04 178 T 0.03 0.01
LL-NN 0.04 178 T 0.03 0.01
NN-PP 0.04 178 T 0.03 0.01
PP-RR 0.07 178 T 0.03 0.04
RR-C 0.11 178 T 0.01 0.10
----------Gable Webs----------
M -L 0_04 96 T
o *N 0.05 117 T
K -p 0.23 553 C
S -R 0.01 36 T
U -T 0.18 234 C
W -V 0.18 216 C
Y -x 0.25 220 C
AA-Z 0.09 218 C
BB-B 0.17 ]69 C
DD-CC 0.09 225 C
FF-EE 0.25 217 C
HH-GG 0.19 217 C
JJ4I1 0.16 215 C
LL*KX 0.12 217 C
NN-MM 0.09 219 C
1"1"-00 0.06 199 C
RR-OO 0.09 282 C
TRUSS
WEIGHT: 279.6 Les
L LOCK 2.0x 4.0 Ctr Ctr 0.00
N LOCK 2.0x 4.0 Ctr Ctr 0_00
1" LOCK 2.0x 4.0 Ctr Ctr 0.00
R LOCK 2.0x 4.0 Ctr Ctr 0.00
T LOCK 2.0x 4.0 Ctr Ctr 0.00
Sl LOCK 3.0x 6.0 Ctr Ctr 0.77
V LOCK 2.0x 4.0 Ctr Ctr 0.00
X LOCK 2.0x 4.0 Ctr Ctr 0.00
Z LOCK 2.0x 4.0 Ctr Ctr 0.00
BLOCK 5.0x 6.0 Ctr~O.l 0.69
CC LOCK 2.0x 4.0 Ctr Ctr 0.00
EE LOCK 2.0x 4.0 Ctr Ctr 0.00
GG LOCK 2.0x 4.0 Ctr Ctr 0.00
S2 LOCK 3_0x 6.0 Ctr Ctr 0.77
II LOCK 2.0x 4.0 Ctr Ctr 0.00
KK LOCK 2.0x 4.0 Ctr Ctr 0.00
MM LOCK 2.0x 4.0 Ctr Ctr 0.00
00 LOCK 2.0x 4.0 Ctr Ctr 0.00
00 LOCK l.Ox 4.0 Ctr Ctr 0.00
CLOCK 4.0x 6.0 Ctr 0.1 0.72
M LOCK 2.0x 4.0 Ctr Ctr 0_00
o LOCK 2.0x 4.0 Ctr Ctr 0.00
KLOCK 2.ax 4.0 Ctr Ctr 0.00
S LOCK 2.0x 4.0 Ctr Ctr 0.00
U LOCK 2.0x 4.0 Ctr Ctr 0.00
w LOCK 2_0x 4.0 Ctr Ctr 0.00
S] LOCK 3.0x 6.0 Ctr Ctr 0.77
Y LOCK l.Ox 4.0 Ctr Ctr 0.00
AA LOCK 2.0x 4.0 Ctr Ctr 0.00
BB LOCK 2.0x 4.0 Ctr Ctr 0.00
DD LOCK 2.0x 4.0 Ctr Ctr 0.00
FF LOCK 2.0x 4.0 Ctr Ctr 0.00
S4 LOCK ].Ox 6.0 Ctr Ctr 0.77
HH LOCK 2.0x 4.0 Ctr Ctr 0.00
JJ LOCK 2.0x 4.0 Ctr Ctr 0.00
LL LOCK 2.0x 4.0 Ctr Ctr 0.00
1 Br
1 Br
1 Br
Truss Design Engineer: Thomas A. Albani
License #: 077357-1
Address: P.O. Box 280055, Tampa, FL 33682
TL Defl
LL Defl
Shear II
-0.24" in A -H
-0.18" in A .M
Grain in N -1"
L/332
L/437
0.48
Plates for each ply each face.
PLATING CONFORMS TO TPI.
PLATE VALUES MAY BE VERIFIED
WITH ROBBINS MANUFACTURING.
GRIP BASED ON SPF & SYP LUMBER
USING GROSS AREA TEST.
Plate - LOCK 20 Ga, Gross
Plate - RHS 20 Ga, Gross
Jt Type PIt Size X Y
A LOCK 4.0x 6.0 Ctr 0.1
A LOCK 2.0x 6.0 Ctr Ctr
Area
Area
JSl
0.72
0.00
RObb.ns Engineering. Inc_IQnhoe Plus"'@ 1996-2007 Vers,on 21 0012 Engineering. Portrait 4120/2007230.46 PM Page 1 of 2
Date Sealed: 4/2012007
~ Q6;~~30 L ~;k
I U# J#Q608030 Ranch Roof
------_..---,-------
NN LOCK
PP LOCK
RR LOCK
2.0x 4.0 Ctr Ctr 0.00
2.0x 4.0 Ctr Ctr 0.00
2.0x 4.0 Ctr Ctr 0.00
REVIEWED BY:
Robbins Engineering, Inc.
6904 Parke East Blvd.
Tampa, FL 33610
REFER TO ROBBINS ENG. GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
Trusses Manufactured by:
TRIANGLE BUILDING PRODUCTS
Analysis Confo~s To:
ANSI/TPI 95 & 02
OH Loading
Soffit psf 2.0
Design checked for LL on BC
per BOCA (section 1606.2.3),
leC/IRe-200) and FBC 2004
(section 1607.1),20.0 pst.
Refer to Gen Det 3 series for
web bracing and plating.
Wind Loads - ANSI / ASeE 7-02
Truss is designed as a Main
Wind~Force Resistance System.
Wind Speed: 120 mph
Mean Roof Height: 25-0
Exposure Catego~: C
Occupancy Factor : 1.00
Building Type: Enclosed
Zone location: Exterior
TC Dead Load 4.0 psf
Be Dead Load : 5.0 psf
Roof Snow Load per ASCE 7~02
Ground Snow Load 45_0 psf
Rain Load 0.0 pst
Importance Factor 1.00
Thermal Factor 1.00
Exposure Factor 1.20
Balanced Load Factor 0.84
Unbalanced Load Factor 1.25
Unbalanced Loads Checked
Load Factors = 1.25 and 0.00
Max compo torce 553 Lbs
Max tens. force 596 Lbs
Quality Control Factor 1.25
~----
Quan Type Span
I 1 TR 380000
LeftOHRight- OH]-~;meenng
1- 0- 0 1- 0- 0 T07041879
--- ---
PI-HI
6
Robb.n<; EnOln""nno In~ 10nlin.. Ph,<;'" ffJ 1996-:?OO7 v..,<;;on;>1 001;> Fnn.n"'''''''o. PfYlr,,,t 41?On11l17 "'In'41> PM P:m",',-,I'
r
I Q608030
1 U# J#Q608030
I
I
Robbins Engineering, Ine./Online Plus'. APPROX. TRUSS
Online Plus -- Version 21.0.012 QQ-C 0.15 355 C 0.00 0.15
RUN DATE: 2Q-APR-Q7 --------Bottom Chords-~-------
TT-Q 0.08 3 C 0.00 0.08
Q -5 0.07 1 T 0.00 0.07
S -u 0.04 0 T 0.00 0.04
U -w 0.01 0 T 0.00 0.01
W .53 0.00 0 T
S3-Y 0.00 0 T
Y -AA 0.01 0 T
AA-BB 0.01 0 T
BS-DD 0.01 0 T
DD-FF 0.01 0 T
FF-S4 0.00 0 T
S4-HH 0.00 0 T
HH-JJ 0.01 0 T 0.00 0.01
JJ-LL 0.01 0 T 0.00 0.01
LL.NN 0.01 0 T 0.00 0.01
NN-PP 0.01 0 T 0.00 0.01
PP-RR 0.03 0 T 0.00 0.03
RR-C 0.10 15 T 0.00 0.10
-------------Webs-------------
TT-SS 0.15 122 T 0.00 0.15
----------Gable Webs----------
Q -p 0.07 70 C 0.01 0.06
S -R 0.15 23] C 0.08 0.07
U -T 0.10 212 C 0.07 0.03
W ~v 0.05 218 C 0.04 0.01
Y -x 0.06 217 C 0.06 0.00
AA-Z 0.04 227 C 0.03 0.01
BB-B 0.03 326 C 0.03 0.00
DD-CC 0.03 227 C 0.03 0_00
FF~EE 0.06 217 C 0.06 0.00
HH-GG 0.04 217 C 0_04 0.00
JJ-II 0.07 215 C 0.07 0.00
LL-KK 0.07 217 C 0.07 0.00
NN~MM 0.07 218 C 0_07 0.00
PP-OO 0.07 204 C 0.07 0.00
RR~QO 0.17 272 C 0.09 0.08
CSI -Size- ----Lumber----
TC 0.15 2x , SPF-#2
BC 0.10 2x , SPF-#2
WB 0.15 2x , SPF-STUD
GW 0.17 2x 3 SPF - STUD
0.06 2x 3 SPF-#2
W -v y -x AA-Z BB-B
DD-CC FF-EE HH-GG
Tf
II
10-3-15
9-10-3
J1
r--QuanTYP;- S-pan-
,1 TR 310900
L_..._____,..._ _.~____.__
---- - --- --- - ----1--- --l
Pl-Hl Left OH Right OH I Engmeenng
6 0 1- 0- 0 T07041879
- -----~ - -- ~ --- -----.
Job
Mark
GIS
Ranch Roof
DG 16-1-5
HO 3-5-11
5x6c::
B
Z CC
'I
3x6-;.-
Sl v
I 1
JlJ
4x6.:..:
C
DG 21-4-13
HO 4-]
EE
GG
]x6..::;-
S2
II
KK
M>I
00
QQ
TT
2x411
Q
S
u
W S3 Y
3x6=
FF $4 HH
3x6=
JJ
NlI
pp
RR
AA
BB
DO
LL
1//////
////
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
/~/"7"'Zlo
'0
10
--j1
~t--
1~-9-0
31-9-0
31-9-0
31.9-0
ALL PLATES ARE LOCK20
See Joint P For Typical Gable Plate Size and Placement
Scale: 0,192" = l'
0.00
0.00
0.00
0.00
WEIGHT: 252.0 LBS
CC LOCK 2.0x 4.0 Ctr Ctr 0_00
EE LOCK 2.0x 4.0 Ctr Ctr 0.00
GG LOCK 2_0x 4.0 Ctr Ctr 0.00
S2 LOCK ].Ox 6.0 Ctr Ctr 0.71
II LOCK 2.0x 4.0 Ctr Ctr 0.00
KK LOCK 2.0x 4.0 Ctr Ctr 0.00
MM LOCK 2.0x 4.0 Ctr Ctr 0.00
00 LOCK 2.0x 4.0 Ctr Ctr 0.00
QO LOCK 2.0x 4_0 Ctr Ctr 0.00
CLOCK 4.0x 6.0 Ctr 0.1 0.66
TT LOCK 2.0x 4.0 Ctr Ctr 0.45
Q LOCK 2.0x 4.0 Ctr Ctr 0.00
SLaCK 2.0x 4.0 Ctr Ctr 0.00
U LOCK 2.0x 4.0 Ctr Ctr 0.00
W LOCK 2.0x 4.0 Ctr Ctr 0.00
S] LOCK ]_Ox 6.0 Ctr Ctr 0.71
Y LOCK 2.0x 4_0 Ctr Ctr 0.00
AA LOCK 2.0x 4.0 Ctr Ctr 0.00
BB LOCK 2_0x 4.0 Ctr Ctr 0.00
DD LOCK 2.0x 4.0 Ctr Ctr 0.00
FF LOCK 2.0x 4.0 Ctr Ctr 0.00
S4 LOCK 3.0x 6.0 Ctr Ctr 0_71
HH LOCK 2.0x 4.0 Ctr Ctr 0.00
JJ LOCK 2.0x 4.0 Ctr Ctr 0.00
LL LOCK 2.0x 4.0 Ctr Ctr 0.00
NN LOCK 2.0x 4.0 Ctr Ctr 0.00
PP LOCK 2.0x 4.0 Ctr Ctr 0.00
RR LOCK 2.0x 4.0 Ctr Ctr 0.00
0_01
0.01
0.01
0.01
Brace truss as follows:
O_C_ From To
TC Cont. O~ 0- 0 31- 9- 0
BC Cont. 0- 0- 0 31- 9- 0
we 1 rows CLB on AA-Z
we 1 rows CLB on BB-B
we 1 rows CLB on DD-CC
Attach CLB with (2}-10d nails
at each web_
psf-Ld Dead Live
TC 7.0 ]7.8
BC 8.0 0.0
TC+BC 15.0 37.8
Total 52.8 Spacing 24.0R
Lumber Duration Factor 1.15
Plate Duration Factor 1.15
TC Fb=1.15 Fc=1.10 Ft=1.10
BC Fbzl.lO Fc=1.10 Ft=1.10
REVIEWED BY:
Robbins Engineering, Inc.
6904 Parke East Blvd.
Tampa, FL 33610
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
TT 3606 2006 U 537 R
Jt
TT
Brg Size
381.0"
Plus 6 Wind Load Case(s)
Plus 2 Unbalanced Load Cases
Truss Design Engineer: Thomas A. Albani
License #: 077357-1
Address' P.O. Box 280055, Tampa, FL 33682
Membr CSI P Lbs Axl-CSI~Bnd
----------Top Chords----------
SS-P 0.05
P -R 0_09
R -T 0.09
T -S1 0.08
Sl-V 0.09
V -x 0.11
X -Z 0.11
Z -B 0.1]
B -CC 0.:12
CC-EE 0.12
EE-GG 0.10
GG-S2 0.08
S2-II 0_08
II-KK 0.08
KK-MM 0.08
MM-OO 0.08
oO-QO 0.12
REFER TO ROBBINS ENG. GENERAL
Required
O"-to- 381"
TL Def!
LL Defl
Shear II
0.00" in RR-C
O.OOR in RR-C
Grain in QO-C
L/999
L/999
0.26
112 T
130T
219 T
297 T
301 T
384 T
473 T
546 T
546 T
47] T
]83 T
299 T
295 T
277 C
298 C
318 C
336C
Plates for each ply each face.
PLATING CONFORMS TO TPI.
PLATE VALUES MAY BE VERIFIED
WITH ROBBINS MANUFACTURING.
GRIP BASED ON SPF k SYP LUMBER
USING GROSS AREA TEST.
Plate - LOCK 20 Ga, Gross
Plate - RHS 20 Ga, Gross
Jt Type PIt Size X Y
5S LOCK 2.0x 4.0 Ctr Ctr
PLOCK 2_0x 4.0 Ctr Ctr
R LOCK 2.0x 4.0 Ctr Ctr
T LOCK 2.0x 4.0 Ctr Ctr
Sl LOCK 3.0x 6.0 Ctr Ctr
V LOCK 2.0x 4.0 Ctr Ctr
X LOCK 2.0x 4.0 Ctr Ctr
Z LOCK 2.0x 4.0 Ctr Ctr
BLOCK 5.0x 6.0 Ctr-O.l
0.00
0_00
0.00
0.04
0.04
0.06
0.07
0.08
0.08
0.07
0.06
0.04
0_04
0.00
0.00
0_00
0.00
0.05
0_09
0.09
0.04
0.05
0.05
0.04
0.05
0.04
0.05
0.04
0.04
0.04
0.08
0.08
0.08
0.12
Area
Area
JSr
0.45
0.00
0.00
0.00
0.71
0_00
0.00
0.00
0.64
Robbins Englneenng. Inc/Online Plus""@1996-2007Verslon21 0012 Englneenng - Portrait 4120/200723046 PM Page 1 of 2
Date Sealed: 4/20/2007
r----
Job
1~~o8030
I U# J#Q608030
T
LGlS
Ranch Roof
Mark
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
Trusses Manufactured by:
TRIANGLE BUILDING PRODUCTS
Analysis Conforms To:
ANSI!TPI 95 & 02
OH Loading
Soffit pst 2.0
Design checked for LL on Be
per BOCA (section 1606.2.3),
lBC/IRe-20D3 and FBe 2004
(section 1607.1), 20.0 pst.
Refer to Gen Det 3 series for
web bracing and plating.
Wind Loads - ANSI / ASeE 7-02
Truss is designed as a Main
Wind-Force Resistance System.
Wind Speed: 120 mph
Mean Roof Height: 25-0
Exposure Category: C
Occupancy Factor : 1.00
Building Type: Enclosed
Zone location: Exterior
TC Dead Load: 4.0 pst
Be Dead Load: 5.0 pst
Roof Snow Load per AseE 7-02
Ground Snow Load 45.0 psf
Rain Load 0.0 pst
Importance Factor 1.00
Thermal Factor 1.00
Exposure Factor 1.20
Balanced Load Factor 0.84
Unbalanced Load Factor 1.25
Unbalanced Loads Checked
Load Factors = 1.25 and 0.00
Max compo force 355 Lbs
Max tens. force 546 Lbs
Quality Control Factor 1.25
r~~~;; _ T~e_~~~:~O
P1-H1
6
Rohhros EnOlORfmnn In~ IOnhn~ PIli""" i!;) 1996-2007 VRrsiOl1 21 0012 FnOlnF!F!nnn. Pnrtr;!j1 4000007 ?104fi PM P"ln~::> of::>
Left
o
OH
Right OH
1- 0- 0
Engineering -"l
_ T070~18~ .--l
__ ___J
lQ~Q~~30 :~-_I- ;;k
I U# J#Q608030 Ranch Roof
r--
I
DG 10-5-2
HO 4-7
Tf
I I
II
6-8-3
6-0-7
I
J
3x4=
A
--,---------
I Quan Type
__L~__ TR
Span
170000
4x4;::;
B
J
P1-H1
8
Q L
3x4::::
Left OH
1- 0- 0
r--Enginc:nng----I
. T07041879 !
j
I
I
I
I
I
I
!
H
'I'~/
"'2x411
D
B
G
I
Right OH
1- 0- 0
DG 10-5-2
HO 4-7
K
M
o
3x4=
C
N
P
r / / LLC/ / / LL / 777-LL/ / / / / / / / / / / 777 / / L /
I
I
L
~I
a
8-6-0
- 10-0-0
17-0-0
SPL
/7j
----j'~
17-0-0
17-0-0
APPROX. TRUSS
L/999
L!999
0.18
Area
Area
JS'
0.68
0.00
0.00
0.00
0.58
0.00
0.00
0.00
0.68
0.00
0.00
0.00
0.00
0.53
0.00
0.00
0.00
Robbins Englneerrng. Ii'lC IOnllne Plus""@ 1996-2007 Versmn 21 0.012 Engineering. POrlra'l 4120/200723047 PM Page 1
ALL PLATES ARE LOCK20
See Joint D Por Typical Gable plate Size and Placement
Scale-
0.344" = 1 ,___~
Robbins Engineering,
21.0.012 E -D
G -F
, -H
J -B
L -K
N -I<
P -0
IDe. /Onl10e Plus'~
0.10 238 T
0.08 199 T
0.11 210 C
0.06 86 C
0.11 210 C
0.08 199 T
0.10 238 T
TL De fl
LL Def!
Shear II
0.00"
0.00"
Grain
in P -C
in P -C
in A -0
Online Plus -- Version
RUN DATE: 20-APR-07
TC
BC
GW
CS'
0.09
0.07
0.11
----Lumber----
SPF-#2
SPF-#2
SPF-STUD
-5ize-
2x 4
2x 4
2x 3
Brace truss
O.C.
TC Cont.
BC Cont.
as follows:
From
0- 0- 0
0- 0- 0
To
17- 0- 0
17- 0- 0
psf-Ld Dead Live
TC 7.0 34.3
BC 8.0 0.0
TC+BC 15.0 34.3
Total 49.3 Spacing 24.0"
Lumber Duration Factor 1.15
Plate Duration Factor 1.15
TC Fb=1.15 Fc=1.10 Ft=1.10
Be Fb=1.l0 Fc=l.lO Ft=1.10
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
A 1850 1095 U 223 R
Jt
A
Brg Size
204.0"
Required
O"-to- 204"
Plus 6 Wind Load Case(s)
Plus 2 Unbalanced Load Cases
Mambr CSI P Lbs AxI-C5I-Bnd
----------Top Chords----------
A -0 0.09 177 C 0.00 0.09
D -F 0.09 86 C 0.00 0.09
F -8 0.07 83 T 0.00 0.07
H -B 0.07 202 T 0.00 0.07
B -K 0.07 202 T 0.00 0.07
K -M 0.07 83 T 0.00 0.07
M -0 0.09 86 C 0.00 0.09
o -C 0.09 177 C 0.00 0.09
--------Bottom Chords---------
A -E 0.07 5 T 0.00 0.07
E -G 0.03 0 T 0.00 0.03
G -I 0.01 0 T 0.00 0.01
I -J 0.01 0 T 0.00 0.01
J -Q 0.01 0 T 0.00 0.01
Q -L 0.00 0 T
L -N 0.01 0 T 0.00 0.01
N -P 0.03 0 T 0.00 0.03
P -C 0.07 5 T 0.00 0.07
----------Gab1e Webs----------
Plates for each ply each face.
PLATING CONFORMS TO TPI.
PLATE VALUES MAY BE VERIFIED
WITH ROBBINS MANUFACTURING.
GRIP BASED ON SPF & gyp LUMBER
USING GROSS AREA TEST.
Plate - LOCK 20 Ga, Gross
Plate - RRS 20 Ga, Gross
Jt Type PIt Size X Y
A LOCK 3.0x 4.0 Ctr Ctr
D LOCK 2.0x 4.0 Ctr Ctr
FLOCK 2.0x 4.0 Ctr Ctr
H LOCK 2.0x 4.0 Ctr Ctr
BLOCK 4.0x 4.0 Ctr Ctr
KLOCK 2.0x 4.0 Ctr Ctr
M LOCK 2.0x 4.0 Ctr Ctr
o LOCK 2.0x 4.0 Ctr Ctr
CLOCK 3.0x 4.0 Ctr Ctr
E LOCK 2.0x 4.0 Ctr Ctr
GLOCK 2.0x 4.0 Ctr Ctr
I LOCK 2.0x 4.0 Ctr Ctr
J LOCK 2.0x 4.0 Ctr Ctr
Q LOCK 3.0x 4.0 Ctr Ctr
L LOCK 2.0x 4.0 Ctr Ctr
N LOCK 2.0x 4.0 Ctr Ctr
PLOCK 2.0x 4.0 Ctr Ctr
REVIEWED BY:
Robbins Engineering, Inc.
6904 Parke East Blvd.
Tampa. FL 33610
REFER TO ROBBINS ENG. GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
Trusses Manufactured by:
TRIANGLE BUILDING PRODUCTS
Analysis Conforms To:
ANSI/TPI 95 & 02
OH Loading
WEIGHT: 107.4 LBS
Soffit psf 2.0
Design checked for LL on BC
per BOCA (section 1606.2.3),
IBC/IRC-2003 and FBC 2004
(section 1607.1), 20.0 psf.
Refer to Gen Det 3 series for
web bracing and plating.
Wind Loads - ANSI / A5CE 7-02
Truss is designed as a Main
Wind-Force Resistance System.
Wind Speed: 120 mph
Mean Roof Height: 25-0
Exposure Category: C
Occupancy Factor : 1.00
Building Type: Enclosed
Zone location: Exterior
TC Dead Load 4.0 psf
BC Dead Load: 5.0 psf
Roof Snow Load per ASCE 7-02
Ground Snow Load. 45.0 psf
Rain Load 0.0 psf
Importance Factor 1.00
Thermal Factor 1.00
Exposure Factor 1.20
Balanced Load Factor 0.76
Unbalanced Load Factor 1.25
Unbalanced Loads Checked
Load Factors = 1.25 and 0.00
Max compo force 227 Lbs
Max tens. force 238 Lbs
Quality Control Factor 1.25
Truss Design Engineer: Thomas A. Albani
LIcense #: 077357-1
Address: P.o. Box 280055, Tampa, FL 33682
Date Sealed: 4/20/2007
L'- -Jo-b - ---~II ~ Mark -- -l-Q~~- ~;-- spa~--p-l=Hl-LeftOH- Right OH
_~803Q__~_!L __~~ TR 170000 8 1~~_ -=-=-_0- 0
i U# J#Q608030 Ranch Roof
I
IT'
I I
I
DG 10-5-2
HO 4-7
4x4-=-
B
6-8-3
6-0-7
I
11
3x4:::
A
~
W:308
R: 924
U: 547
I iW-o-'t
L___
4-5-7
~
D
3x6::o
81
3x4=
8-~O
8-6-0
17-0-0-
ALL PLATES ARE LOCK20
Robbins Engineering.
Online plus -- Version 21.0.012 E-D
RUN DATE: 20-APR-07 D -B
D -F
TC
BC
WB
CSI
0.38
0.44
0.31
-Size-
2x 4
2x 4
2x 3
----Lumber----
SPF-#2
SPF-#2
SPF-STDD
Brace truss
O.C.
TC Cont.
Be Cont.
as follows:
From To
0- 0- 0 17- 0- 0
0- 0- 0 17- 0- 0
psf-Ld Dead Live
TC 7.0 34.3
BC 8.0 0.0
TC+BC 15.0 34.3
Total 49.3 Spacing 24.0"
Lumber Duration Factor 1.15
Plate Duration Factor 1.15
TC Fb=l.lS Fc=l.lO Ft=l.lO
Be Fb=l.lO Fc=l.lO Ft=1.10
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
A 925 547 U 223 R
C 925 547 U 223 R
Jt
A
C
Brg Size
3.5"
3.5"
Required
1.5"
1. 5"
Plus
plus
6 Wind Load Case(s)
2 Unbalanced Load Cases
Membr CSI P Lhs Axl-CSI-Bnd
----------Top Chords----------
A -E 0.38 1073 C 0.00 0.38
E -B 0.38 771 C 0.00 0.38
B -F 0.38 771 C 0.00 0.38
F -C 0.38 1073 C 0.00 0.38
--------Bottom Chords---------
A -D 0.44 902 T 0.20 0.24
D -Sl 0.44 902 T 0.20 0.24
Sl-C 0.34 902 T 0.20 0.14
-------------webs-------------
Ine./Online Plus.
0.27 415 C
0.31 518 T
0.27 415 C
APPROX. TRUSS
TL Defl
LL Defl
Shear II
-0.07"
-0.03"
Grain
in D
in A
in A
-Sl
-D
-E
L/999
L/999
0.35
Plates for each ply each face.
PLATING CONFORMS TO TPI.
PLATE VALUES MAY BE VERIFIED
WITH ROBBINS MANUFACTURING.
GRIP BASED ON SPF & SYP LUMBER
USING GROSS AREA TEST.
Plate - LOCK 20 Ga. Gross
Plate - RHS 20 Ga, Gross
Jt Type PIt Size X Y
A LOCK 3.0x 4.0 Ctr Ctr
E LOCK 1. Ox 3.0 Ctr Ctr
BLOCK 4.0x 4.0 Ctr Ctr
FLOCK 1.0x 3.0 Ctr Ctr
CLOCK 3.0x 4.0 Ctr Ctr
D LOCK 3.0x 6.0 Ctr Ctr
S1 LOCK 3.0x 4.0 Ctr Ctr
REVIEWED BY:
Robbins Engineering, Inc.
6904 Parke East Blvd.
Tampa, FL 33610
REFER TO ROBBINS ENG. GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES,
Trusses Manufactured by:
TRIANGLE BUILDING PRODUCTS
Analysis Conforms To:
ANSI/TPI 95 & 02
OH Loading
Soffit psf 2.0
Design checked for LL on BC
per BOCA (section 1606.2.3),
IBC/IRC-2003 and FBC 2004
(section 1607.1), 20.0 psf.
Wind Loads - ANSI I ASCE 7-02
Robbins Engln€enng. Inc IOnline PluS IV ~ \996-2007 Version 21 0012 Eng'neering - Po"ra,t 4/201200723047 PM Page 1
~--:--c-- ---
I Engmeenng
,
T07041879
-l
I
I
DG 10-5-2
HO 4-7
lx3'i
F
3x4;-::
C
12-6-9
~
W:308
R: 924
U: 547
J~
1-1=0-
17-0-0
Scale 0.344":::; l'
Area
Area
JSI
0.68
0.79
0.58
0.79
0.68
0.44
0.53
WEIGHT: 97.3 LBS
Truss is designed as a Main
Wind-Force Resistance System.
Wind Speed: 120 mph
Mean Roof Height: 25-0
Exposure Category: C
Occupancy Factor : 1.00
Building Type: Enclosed
Zone location: Exterior
TC Dead Load 4.0 psf
Be Dead Load: 5.0 psf
Roof Snow Load per ASCE 7-02
Ground Snow Load 45.0 psf
Rain Load 0.0 psf
Importance Factor 1.00
Thermal Factor 1.00
Exposure Factor 1.20
Balanced Load Factor 0.76
Unbalanced Load Factor 1.25
Unbalanced Loads Checked
Load Factors = 1.25 and 0.00
Max comp. force J.073 Lbs
Max tens. force 902 Lbs
Quality Control Factor 1.25
Truss Design Engineer: Thomas A. Albani
lIcense #: 077357-1
Address: P.O. Box 280055, Tampa, FL 33MQ
Date Sealed: 4/20/2007
I Q60J;~30 -- i ~; -[~~~;.
~u# J#Q608(l30RanCh-Roof --
Type
TR
Span
170000
P1-H1
8
Le ft OH
1- 0- 0
. .Righot OH ll~~:~:
DG 10-5-2
HO 4-7
DG 10-5-2
HO 4-7
Tj
i
I
6xB'i
'I,xv
G
6-8-3
6-0-7
I
~
w:308 (*.)
R: 12992
U:3385
F
axlOl1
.
7x1211
~~ut
8.6-0 11-0-8 I
8-6-0 12-3-12
17-0.0
5-11-8
I
3-5-0
4-8-4
ALL PLATES ARE LOCK20
l
Robbins
Online Plus -- Version 21.0.012
RUN DATE: 20-APR-07
Engineering, Ioe ./Online Plus'. APPROX. TRUSS
51-D 0.43 12039 T 0.25 0.18
D -c 0.76 14360 T 0.29 0.47
---------Webs-------------
G -F 0.09 635 C
F -H 0.47 6429 T
H -E 0.65 3913 C
E -B 0.92 12572 T
E -I 0.65 3913 C
I -0 0.47 6429 T
o -J 0.09 635 C
-----------Sliders------------
A -G 0.08 382 T
J -c 0.08 382 T
***************
.. 2-Ply Truss ..
*******...**.***
CSI -Size- ----Lumber----
TC 0.97 2x 4 SPF-2100
BC 0.76 2x , SP.HOO
WE 0.92 2x , SPF-2100
0.65 2x , SPF-STUD
G .F H .E . .1 D -J
SL 0.08 2x 4 SPF-STUD
Brace truss ., follows: TL Def! -0.]0" in E -SI L/65]
D.C. From To LL Def! -0.22" in . .SI L/908
TC Cont. O. 0- 0 17. O. 0 Shear II Grain in A .F 1. 00
BC Cont. O. 0- 0 17. ,. 0
psf-Ld Dead Live
TC 7.0 ]0.0
BC 18.0 ]0.0
TC~BC 25.0 60.0
Total 85_0 Spacing 24.0"
Lumber Duration Factor 1.15
Plate Duration Factor 1.15
TC Fb=1.00 Fc=I.00 Ft=1_00
BC Fb=1.00 Fc=1.00 Ft=1.00
Plates for each ply each face.
PLATING CONFORMS TO TPI.
PLATE VALUES MAY BE VERIFIED
WITH ROBBINS MANUFACTURING.
GRIP BASED ON SPF . SYP LUMBER
USING GROSS AREA TEST.
Plate - LOCK 20 Ga, Gross
Plate - RHS 20 Ga, Gross
Jt Type PIt Size X Y
A LOCK 6.0x14.0 5.7 4.4
GLOCK ].Ox 4.0 Ctr Ctr
H LOCK 6.0x 8.0 Ctr Ctr
BLOCK 7.0x 8.0 Ctr-2.1
I LOCK 6.0x 8.0 Ctr Ctr
J LOCK ].Ox 4.0 Ctr Ctr
CLOCK 6.0x14.0-5.7 4.4
F LOCK 8.0x10.0~0.8-1_2
E LOCK 7.0x12.0 Ctr~O.]
Sl LOCK 7.0x 6.0 Ctr Ctr
o LOCK 8.0x10.0 0.8-1.2
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
A 12992 ]]86 U 220 R
C 12906 ]]]2 U 220 R
Area
Area
JSI
0.92
0.64
0.95
0.98
0.95
0.64
0.92
0.88
0.94
0.95
0.88
Jt
A
C
Brg Size
].5"
3.5"
Required
5.4" **
5.]" **
1 Girder. Snow Load
Fctrs - Lbr 1.15 PIt 1.15
Dead Live* From To
14 69 0.0' 17.0'
411 1025 0.0' 17.0'
LC'
Dur
pH
TC V
BC V
REVIEWED BY:
Robbins Engineering, Inc.
6904 Parke East Blvd.
Tampa, FL 33610
Plus 6 Wind Load Case{s}
Plus 2 Unbalanced Load Cases REFER TO ROBBINS ENG. GENERAL
NOTES AND SYMBOLS SHEET FOR
Membr CSI P Lbs Axl-CSI-Bnd ADDITIONAL SPECIFICATIONS.
----------Top Chords---------- NOTES:
A -G 0.97 17]60 C 0_60 0.37 Trusses Manufactured by:
G -R 0.79 16932 C 0.59 0.20 TRIANGLE BUILDING PRODUCTS
H -B 0.51 11809 C 0.26 0.25 Analysis Conforms To:
B -I 0.51 11809 C 0.26 0.25 ANSI/TP1 95 . 02
I -J 0.79 16932 C 0.59 0.20 Girder Common
J -c 0.97 17360 C 0.60 0.37 Loading BC
------~-Bottom Chords--------- Span 32- 0- 0
A -F 0.76 14360 T 0.29 0.47 2 COMPLETE TRUSSES REQUIRED.
F -E 0.55 12039 T 0.25 0.30 Fasten together in staggered
E -Sl 0.55 12039 T 0.25 0.30 pattern. (1/2" bolts -OR-
Robbins Engineering. Inc.lOnllne Plus"'@1996.2007VerSlon21 0 012 Engineenng. Portrait 4120/200723047 PM Page 1 of 2
6xa.:::-
51
7x6=
D
ax1011
~
(Ul W:3Da
R:1Z905
U:3332
I7.0.0 . co!
17-0-0 .
13-7-0
I
Scale 0,351" = l'
WEIGHT: 152.3 LBS
SDS3 screws -OR- 10d nails
as each layer is applied.)
----Spacing (In) ----
Rows Nails Screws Bolts
TC 1 12 24 0
BC 2 4.5 9 0
we 1 8 a
Web connection Exception
Use 4" spacing for screws or
nails on the following webs
H -E E-I
OH Loading
Soffit psf 2.0
Design checked for LL on BC
per BOCA (section 1606.2.3),
lBC/IRC-2003 and FBC 2004
(section 1607.1), 20.0 psf.
Use properly rated hangers for
loads framing into girder
truss.
Wind Loads ~ ANSI/ ASCE 7-02
Truss is designed as a Main
Wind-Force Resistance System.
Wind Speed, 120 mph
Mean Roof Height: 25-0
Exposure Category: C
Occupancy Factor : 1.00
Building Type: Enclosed
Zone location: Exterior
TC Dead Load 4.0 psi
Be Dead Load: 11.0 psf
Roof Snow Load per ASCE 7-02
Ground Snow Load 45.0 psf
Rain Load 0.0 psf
Truss Design Engineer: Thomas A. Albani
License #: 077357~ I
Address: P.O. Box 280055, Tampa, FL 33682
Date Scaled. 4120/2007
[-Q6~~~~~-I~~.
LE# J#Q608030 Ranch Roof
Quan
1*2P
Type
TR
1. 00
1.00
1. 20
0.76
1. 25
Importance Factor
Thermal Factor
Exposure Factor
Balanced Load Factor
Unbalanced Load Factor
Unbalanced Loads Checked
Load Factors z 1.25 and 0.00
Max compo force 17360 Lbs
Max tens. force 14360 Lbs
Quality Control Factor 1.25
Span
170000
P1-H1
8
Robbins Engineering, Inc tOnline Plus"'@1996-2007Version21 0012 Enllineerinll' Portrait 4/201200723047 PM Paqe 2 of 2
~~f~_ or-Rig~t~OH I ~~~~:~:nE-1
_J
I Q60J;~30 _ r~;~~
ru#~#Q608030 Ranch Roof
I
. -r Q~an ~e
---~---_._----_.~
Span
380000
Pl-R1
6
~ft OHRight OR -II Engm''':;n~~j
1- 0- 0 1- 0- 0 T07041879
--~---
DG 21-4-13
HO 4-]
5x6=
B
DG 21-4-13
HO 4-3
-~
4x6~
5
lO-3~15
9-10-]
11
10- 0- 0
10- 0- 0
3x8:1
4x6=
e
Cant:4- 4 M
W:308
R: 1352
U: 626
o
Te 0
Be 0
~
K
2x411
I'
W:308
R:2172
U: 571
N
#7x8=
L
6x8=
U
.2lt411
,
W:308
R,2336
U: 970
7-5-12
7-5-12
12-0-12
12-0-12
114-11-61
r
D
..1.~~O-O_-L~:z':}_~^!.'_1--~1:.3-14__+-___3_8-0-0
22.].4 29-3-14 38-0-0
-38-0-0
ALL PLATES ARE LOCK2Q, # = PLATE SELECTED IN PLATE MONITOR
Scale: 0.166" = l'
L...___
Robbins Engineering, IDc./Online Plus'.
Online Plus -~ Version 21.0.012
RUN DATE: 20-APR-07
APPROX. TRUSS
WEIGHT: 268.3 LBS
Q LOCK 4.0x 8.0 Ctr Ctr 0.63
V LOCK 3.0x 6.0 Ctr 0.2 0.75
Te
eS1 -Size- ----Lwnber----
0.89 2x 4 SP-24DO
0.86 2x 4 SPF~#2
A -51 Sl-B
0.58 2. 4 SPF-2100
B -S2
0.71 2x , SPF-2100
0.]8 2x 8 SP-2400
N -L
0.68 2x SPP-2100
L -e
0.86 2x 3 SPF-STUD
0.51 2x 3 SPF-#2
N -0 L -5 L -P
0.52 2x 3 SPF-#2
0.72 2x 3 SPF-STUD
2x , SPF-#2
Membr CSI P Lbs Ax1-CSI-Bnd
----------Top Chords~~
A -G 0.8] 2]85 C 0.00 0.8]
G -Sl 0.86 28]9 C 0_0] 0.8]
Sl-0 0.]9 2756 C 0.09 0.]0
o -R 0.]4 1805 C 0.04 0.]0
R -B 0.34 1405 C 0.01 0.3]
B -S 0.31 1412 C 0.01 0.]0
S -S2 0.58 2782 C 0.09 0.49
S2-P 0.77 2953 C 0.04 0.7]
P -C 0.89 3812 C 0.20 0.69
--------Bottorn Chords---------
A -K 0.24 2129 T 0.12 0.12
K -N 0.71 2131 T 0.12 0.59
N -L 0.38 248] T 0.09 0.29
L -U 0.55 ]435 T 0.32 0.23
U -C 0.68 3435 T 0.]2 0.36
-------------Webs------~------
K 4G 0.86 2047 C
G -N 0.81 1346 T
N.O 0.22 575 T
V -S 0.51 975 T 0.3]
L -v 0.51 973 T 0.33
L -P 0.43 1111 C
U -p 0.09 156 T
------Attic Chords (Top) ------
a -Q 0.52 1378 C 0.22 0.30
Q -v 0.21 24 T 0.00 0_21
-- -- -- -Attic Webs (Top) -- --
R -Q 0.27 504 C
Q.B 0.57 946 T
o -S 0.72 1642 C
# = Plate Monitor used
Be
REVIEWED BY:
Robbins Engineering, Inc.
6904 Parke East Blvd.
Tampa, FL 33610
Brace truss .. follows:
D.C. From To
Te Cont. 0- 0- 0 38- O. 0
Be Cont. 0- 0- 0 38- 0- 0
WB 1 rows eLB on L -P
Attach eLB with (2) -lOd nails
.t each web.
psf-Ld Dead Live
Te 7.0 30_0
Be 8.0 0.0
TC+BC 15.0 30.0
Total 45.0 Spacing 24.0"
Lumber Duration Factor 1.15
Plate Duration Factor 1.15
Te Fb=1.15 Fc=1.l0 Ft..1.10
Be Fb,,1.10 Fc..1.10 Ft=1.10
0.18
0.18
1 Br
REFER TO ROBBINS ENG. GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
Trusses Manufactured by:
TRIANGLE BUILDING PRODUCTS
Analysis Conforms To:
ANSI/TPI 95 & 02
OH Loading
Soffit psf 2.0
Run vertical thru bottom chord
Joint N
Design checked for LL on BC
per BOCA (section 1606.2_3),
IBC/IRC-2003 and FBC 2004
(section 1607.1), 20.0 pst.
NOTE: USER MODIFIED PLATES
This design may have plates
selected through a plate
monitor.
Wind Loads - ANSI / ASCE 7-02
Truss is designed as a Main
wind-Force Resistance System.
Wind Speed: 120 mph
Mean Roof Height: 25-0
Exposure Category: C
Occupancy Factor : 1.00
WB
ACT
AWT
WG
TL Defl
LL Defl
Shear //
-0.42"
-0.32"
Grain
in N -L
in N -L
in A -G
L/851
L/999
0.60
Total Load Reactions (Lbs)
Jt Down uplift Horiz-
A 1353 626 u 354 R
K 2173 572 U
C 2337 970 U 357 R
Plates for each ply each face.
PLATING CONFORMS TO TPI.
PLATE VALUES MAY BE VERIFIED
wITH ROBBINS MANUFACTURING.
GRIP BASED ON SPF & SYP LUMBER
USING GROSS AREA TEST.
Plate - LOCK 20 Ga, Gross
Plate - RHS 20 Ga, Gross
Jt Type PIt Size X Y
A LOCK 4.0x 6_0 Ctr Ctr
GLOCK 4.0x 6.0 Ctr Ctr
Sl LOCK 3.0x 6.0 Ctr Ctr
o LOCK 3.0x 6.0-0.2 0.3
R LOCK 2.0x 4.0 Ctr Ctr
BLOCK 5.0x 6.0 Ctr-0.1
S LOCK 4_0x 6_0 Ctr Ctr
S2 LOCK 3.0x 8.0 Ctr Ctr
PLOCK 3.0x 6.0 Ctr Ctr
CLOCK 4.0x 6.0 Ctr 0.1
CLOCK 3.0x 8.0 Ctr Ctr
KLOCK 2.0x 4.0 Ctr Ctr
N# LOCK 7.0x 8.0 1.2 0.9
L LOCK 6.0x 8.0 Ctr 1.2
U LOCK 2.0x 4.0 Ctr Ctr
Jt Brg Size Required
A 3.5" 1.6"
K 3.5" 2_5"
e 3.5" 3.0"
Le. 1 Attic & Snow Load
Pur Pctrs Lbr 1.15 PIt 1.15
pH Dead Live* From To
Te V 14 " 0.0' 38.0'
Be V 16 0 0_0' 38.0'
Be V 10 60 12.2' 22.2'
MA V 10 0 12.1' 22.3'
MAV 10 0 0.2' 6.1'
MAV 10 0 0.2' 7.9'
Plus , Wind Load Case(s)
Plus 2 Unbalanced Load Cases
Area
Area
JS1
0.75
0.81
0.84
0.83
0.38
0.69
0.83
0.97
0.82
0.91
0.00
0.62
0.81
0.78
0.40
Truss Design Engineer: Thomas A. Albani
LIcense #: 077357-1
Address: P.O. Box 280055. Tampa, FL 33682
RObbins Engineering, Inc./Online Plus"'@1995-2007Version21,0,012Engineering- Portra,t 4/20/20072.30'48 PM Page 1 of 2
Date Sealed: 4/20/2007
I------~. I IE~gm'ering -I
Job 1 Mark Quan Type Span Pl-Hl Left OH Right OH
~608030 T3 3 TR 380000 6 1- 0- 0 1- 0- 0 I 1'07041879 .
--_.---,,--
l_U:# J_#Q608030 Ranch Roof J
-. ------
Building Type: Enclosed
Zone location: Exterior
TC Dead Load 4.0 pst
Be Dead Load : 5.0 psi
Roof Snow Load per ASCE 7-02
Ground Snow Load 45.0 psf
Rain Load 0.0 psf
Importance Factor 1.00
Thermal Factor 1.00
Exposure Factor 1.20
Balanced Load Factor 0.84
Unbalanced Load Factor 1.25
Unbalanced Loads Checked
Load Factors = 1.25 and 0.00
Max compo force 3812 Lbs
Max tens. force 3435 Lbs
Quality Control Factor 1.25
Robbins ErlQlneenflQ, InC.lOnline PlusTU@1996-2007VerSlon21.0.012EnQineerina-POI1ralt 4/20/200723048 PM Paqe 2 of 2
1-;J~3~ -T--~~k--~~;~T~~
I u. ""':::":,"""'''' .
I HO 4-3
! IT
II
110Ls
I
I
f-_'~~O -12
12~O-12
114-11-61
--~~~:---Pl~Hi- ~~f~_ O~ -Rli_9~t_-~1I] ~~~~:7~~-1
~
I
I
I
I
!
I
I
I
W'~08 II
R;2339
U, 9" i
J~11
Scale 0'66" = ~
Sx6=
B
DG 21-4-13
HO 4-3
9-10-3
3xB~
S2
4x6=
A
3x8!1
4x6=
e
Cant:4- 4 ~
W: 308
R: 1283
U: 472
_~9t-6-1-12
BETg 6-1-12
~
K
2x411
~
w:30a
R:2623
u: 729
N
#7x8=
L
6x8=
U
lx411
19_-()~2-3-4
22-3-4
29-3-14
-29-3-14
38-0-0
~8-0-0
L
38-0-0
ALL PLATES ARB LOCK20, # : PLATE SELECTED IN PLATE MONITOR
Robbins Engineering, Ine./Online Plus~
Online Plus -- Version 21.0.012
RUN DATE: 20-APR-07
APPROX. TRUSS
WEIGHT: 268.4 LBS
Q LOCK 4.Qx 8.0 Ctr Ctr 0.64
V LOCK 3.0x 6.0 Ctr 0.2 0.75
eS1 -Size- ----Lumber----
Te 0.91 2. 4 SPF-#2
0.59 2. 4 SPF-2100
B -S2
0.89 2. 4 SP-2400
S2-C
Be 0.68 2. 6 SPF-2100
0.37 2. 8 SP-2400
N -L
0.68 2. 4 SPF-2100
L -e
WB 0.89 2. 3 SPF-STUD
0.68 2. 3 SPF-#2
G -N N -0 L -S L -p
ACT 0.53 2. 3 SPP-#2
AWT 0.72 2. 3 SPF.STUD
WG 2. 6 SPF-#2
Membr CSI P Lbs Axl~CSI-Bnd
----------Top Chords--------~-
A -G 0.91 2277 C 0.10 0.81
G -51 0.85 2843 C 0.04 0.81
Sl-O 0.60 2758 C 0.09 0.51
o -R 0.55 1760 C 0.04 0.51
R -B 0.35 1397 C 0.01 0.34
B -S 0.30 1407 C 0.01 0.29
S -S2 0.59 2795 C 0.09 0.50
S2-P 0.78 2959 C 0.04 0.74
P ~C 0.89 3818 C 0.20 0.69
------~-Bottom Chords---------
A -K 0.27 2033 T 0.12 0.15
K -N 0.68 2034 T 0.12 0.56
N -L 0.37 2496 T 0.09 0.28
L -u 0.55 3441 T 0.32 0.23
U -C 0.68 3441 T 0.32 0.36
-----------~~Webs-------------
K -G 0.89 2459 C
G -N 0.68 1983 T
N.O 0.30 567 T
V -S 0.52 980 T 0.33
L -v 0.52 978 T D.33
L -p 0.43 1112 C
U -P 0.09 156 T
~-----Attic Chords (TOp) ---~--
o -Q 0.53 1386 C 0.23 0.30
o -v 0.21 26 T 0.00 0.21
--.----Attic Webs (Top) -------
R.O 0.24 442 C
o -B 0.56 940 T
Q -S 0.72 1646 C
# = Plate Monitor used
Brace truss as follows:
O.C. From To
TC Cant. 0- 0- 0 38- 0- 0
BC Cant. 0- 0- 0 38- 0- 0
WB 1 rows CLB on L -P
Attach CLB with (2}-10d nails
lit each web.
0.19
0.19
1 Br
REVIEWED BY,
Robbins Engineering, Inc.
6904 Parke East Blvd.
Tampa, FL 33610
REFER TO ROBBINS ENG. GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
Trusses Manufactured by:
TRIANGLE BUILDING PRODUCTS
Analysis Conforms To:
ANSI/TPI 95 & 02
OR Loading
Soffit psf 2.0
Run vertical thru bottom chord
Joint N
Design checked for LL on BC
per BOCA (section 1606.2.3),
IBC/IRC-2003 and FBC 2004
(section 1607.1). 20.0 psf.
NOTE: USER MODIFIED PLATES
This design may have plates
selected through a plate
monitor.
Wind Loads - ANSI / ASCE 7-02
Truss is designed as a Main
Wind-Force Resistance System.
Wind Speed, 120 mph
Mean Roof Height: 25-0
Exposure Category: C
Occupancy Factor : 1.00
psf-Ld Dead Live
TC 7.0 30.0
BC 8.0 0.0
TC+BC 15.0 30.0
Total 45.0 Spacing 24.0"
Lumber Duration Factor 1.15
Plate Duration Factor 1.15
TC Fb~1.l5 Fc=1.10 Ft=1.10
BC Fb=1.10 Fc=1.10 Ft~1.10
TL Den
LL Den
Shear / /
-D.43"
.0.33"
Grain
in N
in N
in G
-L
-L
-Sl
L/874
L/999
0.57
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
A 1283 473 U 354 R
K 2624 729 U
C 2339 966 U 357 R
Plates for each ply each face.
PLATING CONFORMS TO TPI.
PLATE VALUES MAY BE VERIFIED
WITH ROBBINS MANUFACTURING.
GRIP BASED ON SPF & SYP LUMBER
USING GROSS AREA TEST.
Plate - LOCK 20 Ga, Gross
Plate - RHS 20 Ga, Gross
Jt Type PIt Size X Y
A LOCK 4.0x 6.0 Ctr Ctr
GLOCK 4.0x 6.0 Ctr Ctr
51 LOCK 3.0x 8.0 Ctr Ctr
o LOCK 3.0x 6.0-0.2 0.3
R LOCK 2.0x 4.0 Ctr Ctr
BLOCK 5.0x 6.0 Ctr-0.1
S LOCK 4.0x 6.0 Ctr Ctr
52 LOCK 3.0x 8.0 Ctr Ctr
PLOCK 3.0x 6.0 Ctr Ctr
CLOCK 4.0x 6.0 Ctr 0.1
CLOCK 3.Dx 8.0 Ctr Ctr
KLOCK 2.0x 4.0 Ctr Ctr
N# LOCK 7.0x 8.0 0.9 0.9
L LOCK 6.0x 8.0 Ctr 1.2
U LOCK 2.0x 4.0 Ctr Ctr
Area
Area
JSI
0.75
0.92
0.89
0.83
0.38
0.69
0.8]
D.98
0.82
0.91
0.00
0.81
0.88
0.78
0.40
Truss Design Engineer: Thomas A. Albani
LIcense #: 077357.1
Address: P.O. Box 280055, Tampa, FL 33682
Jt Brg Size Required
A ].5" 1. 5"
K ].5" ].08
e 3.5" 3.0"
Le, 1 Attic . Snow Load
Dur Fctrs - Lbr 1.15 Plt 1.15
pH Dead Live* From To
Te V 14 76 0.0' 38.0'
Be V 16 0 0.0' 38.0'
Be V 10 60 12.2' 22.2'
MA V 10 0 12.1' 22.3'
MAV 10 0 0.2' 6.1'
MAV 10 0 0.2' 7.9'
Plus 6 Wind Load Case(s)
Plus 2 Unbalanced Load Cases
RObb,ns Eng,neenng. Inc IOnline Plus"'@1996-2007Version210012Engineenng- Portrail 4120/200723048 PM Page 1 of 2
Date Sealed. 4/20/2007
[~6~~~-L ~~~__J
U# J#Q608030 Ranch Roof
Building Type: Enclosed
Zone location, Exterior
TC Dead Load 4.0 psf
Be Dead Load : 5.0 psf
Roof Snow Load per ASCE 7-02
Ground Snow Load 45.0 psf
Rain Load 0.0 paf
Importance Factor 1.00
Thermal Factor 1.00
Exposure Factor 1.20
Balanced Load Factor 0.84
Unbalanced Load Factor 1.25
Unbalanced Loads Checked
Load Factors = 1.25 and 0.00
Max compo force 3818 Lbs
Max tens. force 3441 Lbs
Quality Control Factor 1.25
Quan
4
Type
TR
Span
380000
P1-H1
6
Left OH
1- 0- 0
Robbins Enqmeenna Inc.lOnline P1us "'@1996-2007VerSlon21.00t2Enaineenna-Portralt 4/20/2007230.48 PM Pact' 2 of 2
Right
1- 0-
OH
o
~~~~~~~~]
~------
I Job
I Q6mW30
i U# J#Q608030
--,--------,----- -- -
Mark I Quan Type
l T5 L_~ __'l'~
Ranch Roof
DG 16-1-5
HO 3-5-11
5x6=.:
B
IT
61
3x6-;::.
F
1I~ O~ 0
10-3-15
9-10-3
J
4x8=
l____
D
3x411 [
HGR
R:2266
U: 780
~
Id
.
7x6::::
5-9-12
5-.9-12
9.4.10
12-9-0
:1"6-0-4
Span
310900
I
3x6
16-0-4
31-9.0
G~~~;7~9j
~]
I
I
P1-H1
6
Left OH
o
Right OH
1- 0- 0
DG 21-4-13
HO 4-3
3x6.;;:;-
H
3x811
4x6=
C I
~
I
w:308 I
R:2161
U: 896
31-9-0 ----ff1 I
31-9-0
----cJ 0
- ~
Scale 0.192" =,' J
G
7x12=
L
2x411
23-0-14
23-0-i4:
ALL PLATES ARB LOCR20
Engineering, Inc./Online Plus'. APPROX.
H -S1 0.74 2559 C 0_07 0.67
Sl-M 0.95 2700 C 0.04 0.91
M -C 0.97 3466 C 0.06 0.91
------~-Bottom Chords--.------
D -E 0.89 360 T 0.00 0.89
E -G 0.96 2272 T 0.07 0.89
G -L 0.92 3127 T 0.29 0.63
L -C 0.67 3128 T 0.29 0.38
--.-~--------Webs-------------
D -A 0.91 2539 C WindLd
A -E 0.88 2576 T
E -p 0.31 376 C
I -H 0.98 831 T 0.26
G -I 0.98 828 T 0.26
G -M 0.49 1254 C
L -K 0.15 249 T
------Attic Chords (Top) ____u
F -J 0.43 1196 C 0.16 0.27
J -I 0.24 97 T 0.03 0.21
---~-.-Attic Webs (Top)-------
K -J 0.18 402 C
J -B 0.51 852 T
J -H 0.59 1345 C
Robbins
Online Plus -- Version 21.0.012
RUN DATE: 20-APR-07
IC
BC
CSI
0.97
0.96
0.92
G -C
0.98
0.91
D .A
0.43
0.59
-Sili:e-
2x 4
2x 8
2x 4
----Lumber----
SPF-2100
SP-2400
SPF-2100
2x 3
2x 3
E .F
2x 3
2x 3
2x 6
SPF-#2
SPF-STUD
L -M
SPF-#2
SPF-STUD
SPF-#2
WB
ACT
AWI
WG
Brace truss as follows:
a-c. From To
TC Cont. 0- 0- 0 31- 9- 0
BC Cont. 0- O~ 0 J1~ 9. 0
we 1 rows CLB on G -M
Attach CLB with (2)-IOd nails
at each web.
psf-Ld Dead Live
Te 7.0 30.0
BC 8.0 0.0
TC+BC 15.0 30.0
Total 45.0 Spacing 24.0"
Lumber Duration Factor 1.15
plate Duration Factor 1.15
TC Fb~I.l5 Fc~I.10 Ft~1.10
BC Fb~1.10 Fc~l.lO Ft~1.10
TL Defl
LL Defl
Shear //
-0.95" in E -G
-0.78" in E -G
Grain in SI-M
Plates for each ply each face.
PLATING CONFORMS TO TPI_
PLATE VALUES MAY BE VERIFIED
WITH ROBBINS MANUFACTURING.
GRIP BASED ON SPF & SYP LUMBER
USING GROSS AREA TEST.
Flate - LOCK 20 Ga, Gross
Plate - RHS 20 Ga, Gross
Jt Type PIt Size X Y
A LOCK 5.0x 6.0 0.5-0.3
FLOCK 3.0x 6.0-0.2 0.3
KLOCK 2.0x 4.0 1.5 0.8
BLOCK 5.0x 6.0 Ctr-0.1
H LOCK 3.0x 6.0 Ctr Ctr
Sl LOCK 3.0x 8.0 Ctr Ctr
M LOCK 3.0x 6.0 Ctr Ctr
CLOCK 4.0x 6.0 Ctr 0.1
CLOCK J.Ox 8.0 Ctr Ctr
D LOCK 3_0x 4_0 0.2 Ctr
E LOCK 7.0x 6.0-0.5-0.6
GLOCK 7.0x12.0 Ctr 1.8
L LOCK 2.0x 4.0 Ctr Ctr
J LOCK 4.0x 8.0 Ctr Ctr
I LOCK 3.0x 6.0 Ctr 0.2
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
D 2266 781 U 438 R
C 2161 897 U 315 R
Jt Brg Size Required
D 3.5" 1.9"
C 3.5" 2.7"
LCO 1 Attic . Snow Load
Dur Fctrs Lbr 1.15 PH 1.15
plf Dead Live- From 10
TC V 14 76 0.0' 31.8'
BC V 16 0 0.0' 31.8 '
BC V 20 60 5.9' 15.9'
MAV 10 0 5.9' 16.0'
MAV 10 0 0.3 ' 6-1 '
MAV 10 0 0.3' 7.9'
Plus 6 wind Load Case(s)
Plus 2 Unbalanced Load Cases
Membr CSI P Lbs Axl-CSI-Bnd
------Top Chords----------
0.66 2503 C 0.03 0.63
0.64 1547 C 0.01 0.63
0.14 1304 C 0.00 0.14
0.21 1316 C 0.04 0.17
REVIEWED BY:
Robbins Engineering, Inc.
6904 Parke East Blvd_
Tampa, FL 33610
A -F
F -K
K -B
B -H
REFER TO ROBBINS ENG. GENERAL
NOTES AND SYMBOLS SHEET FOR
Robbins EngIneering. Inc/Online Plus"'@1996--2007Version21 0 012 Engineering. Portrait 4/20/20072.30.49 PM Page 1 012
Date Sealed: 4/20/2007
0.72
0.72
1 Br
L/392
L/479
0.65
Area
Area
JSI
0.94
0.72
0.70
0.64
0.97
0.94
0.93
0.92
0.00
0.99
0.89
0.60
0.40
0.56
0.75
TRUSS WEIGHT: 239.5 LBS
ADDITIONAL SPECIFICATIONS.
NOTES:
Trusses Manufactured by:
TRIANGLE BUILDING PRODUCTS
Analysis Conforms To:
ANSI/TPI 95 & 02
OR Loading
Soffit psf 2.0
Run vertical thru bottom chord
Joint G
Design checked for LL on BC
per BOCA (section 1606.2.3),
IBC/IRC-2003 and FBC 2004
(section 1607.1), 20.0 pst.
Wind Loads - ANSI / ASCE 7-02
Truss is designed as a Main
Wind-Force Resistance System.
Wind Speed: 120 mph
Mean Roof Height: 25-0
Exposure Category: C
Occupancy Factor : 1.00
Building Type: Enclosed
Zone location: Exterior
TC Dead Load: 4.0 psf
BC Dead Load: 5.0 psf
Roof Snow Load par ASeE 7-02
Ground Snow Load 45.0 psf
Rain Load 0.0 psf
Importance Factor 1.00
Thermal Factor 1.00
Exposure Factor 1.20
Balanced Load Factor 0.84
Unbalanced Load Factor 1.25
Unbalanced Loads Checked
Load Factors ~ 1.25 and 0.00
Max compo force 3466 Lbs
Max tens. force 3128 Lbs
Truss Design Engineer: Thomas A. Albani
License #: 077357-1
Address: P.O. Box 280055, Tampa, FL 33682
I~m_---r .
Q6;~~30 1 ~;k
[ui. J#Q608030 Ran<=h Roof
Quality Control Factor 1.25
I Quan
8
--'----
Type
TR
Span
310900
PI-HI
6
Robbins Engineering, Ine/Onllne Plus no@ 1996-2007 VerS10ll21 0012 Engineering - Portraol 4120/200723049 PM Paoe 2 of 2
Left OH
o
Right OH
1- 0- 0
'~~~:7~~g9]
_J
Job
Mark
Q608030
U# J#Q608030
Ranch
VI
Roof
DG 3-8-5
HO 4
-[1
, I
2-0-13
2-0-12
_U
2x4":/
I
l__
Tel
aCid
Quan
1
Span
60109
PI-HI
8
Left OH
o
Right OH
o
.~~~:;1';;9 J
,
Type
VL.SB
4x4:-::
--1
D
*2x41~
DG 3-8-6
HO 4
l
I
I
I
i
I
6-1-9
ALL PLATES ARE LOCK20
See Joint D For Typical Gable Plate Size and Placement
I
6-1-9
6-1-9------
Robbins Engineering,
Online Plus -- Version 21.0.012
RUN DATE: 2Q-APR-07
Ine./Online Plus~ APPROX. TRUSS
Scale: 0.699" :;- l'
TC
BC
GW
CSI
0.23
0.20
0.04
-size-
2x 3
2x 3
2x 3
----Lumber----
SPF-#2
SPF-#2
SPF-STUD
Brace truss
D.C.
Cont.
Cont.
follows:
From
0- 0- 0
0- 0- 0
To
6- 1- 9
6- 1- 9
as
TC
BC
psf-Ld Dead Live
TC 7.0 34.3
BC 8.00.0
TC+BC 15.0 34.3
Total 49.3 Spacing 24.0.
Lumber Duration Factor 1.15
Plate Duration Factor 1.15
TC Fb=1.15 Fc=l.IO Ft=l.lO
Be Fb=1.10 Fc=1.10 Ft=1.10
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
A 543 320 U 71 R
Jt
A
Brg Size
73.6"
74"
Required
O"-to-
Plus
Plus
6 Wind Load Case(s)
2 unbalanced Load Cases
Membr CSI P Lbs Axl-CSI-Bnd
----------Top Chords----------
A -B 0.23 92 C 0.00 0.23
B -C 0.23 92 C 0.00 0.23
--------Bottom Chords---------
A -D 0.20 2 C 0.00 0.20
D -C 0.20 2 C 0.00 0.20
----------Gable Webs----------
D -B 0.04 131 C
TL Defl
LL Defl
Shear II
L/999
L/999
0.26
-0.01"
-0.01"
Grain
in D
in D
in A
-C
-C
-B
Plates for each ply each face.
PLATING CONFORMS TO TPI.
PLATE VALUES MAY BE VERIFIED
WITH ROBBINS MANUFACTURING.
GRIP BASED ON SPF & SYP LUMBER
USING GROSS AREA TEST.
Plate - LOCK 20 Ga, Gross
Plate - RHS 20 Ga, Gross
Jt Type PIt Size X Y
A LOCK 2.0x 4.0 0.1 Ctr
BLOCK 4.0x 4.0 Ctr-0.3
CLOCK 2.Qx 4.0-0.1 Ctr
D LOCK 2.0x 4.0 Ctr Ctr
Area
Area
JSI
0.59
0.46
0.59
0.00
REVIEWED BY:
Robbins Engineering, Inc.
6904 Parke East Blvd.
Tampa, FL 33610
REFER TO ROBBINS ENG. GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
Trusses Manufactured by:
TRIANGLE BUILDING PRODUCTS
Analysis Conforms To:
ANSI/TPI 95 & 02
Design checked for LL on BC
per BOCA (section 1606.2.3),
IBC/IRC-2003 and FBC 2004
(section 1607.1), 20.0 psf.
Wind Loads - ANSI / ASCE 7-02
Truss is designed as a Main
Wind-Force Resistance System.
Wind Speed: 120 mph
Mean Roof Height: 25-0
Exposure Category: C
Occupancy Factor : 1.00
Building Type: Enclosed
Zone location: Exterior
TC Dead Load 4.0 psf
BC Dead Load: 5.0 psf
Roof Snow Load per ASCE 7-02
Ground Snow Load 45.0 psf
Robbins Engineering, Inc fOnljne Plus""@ 199&-2007 Version 21 0012 Engineenng. Portrait 4/20/200723049 PM Page 1
WEIGHT: 20.3 LBS
Rain Load 0.0 psf
Importance Factor 1.00
Thermal Factor 1.00
Exposure Factor 1.20
Balanced Load Factor 0.76
Unbalanced Load Factor 1.25
Unbalanced Loads Checked
Load Factors = 1.25 and 0.00
Max comp. force 131 Lbs
Max tens. force 96 Lbs
Quality Control Factor 1.25
Truss Design Engineer: Thomas A. Albani
License #: 077357-1
Address: P,O. Box 280055, Tampa, FL 33682
Date Sealed: 412012007
I Q608030
I U# J#Q608030
I
I
I
I
I
I
Job
Mark
V2
Ranch Roof
rT7T / /l
o
I : I
o
~I
.
------
Quan
1
Type
SP
Span
30409
P1-H1
8
T
I
fDG
'I HO
I
1-10-2
12
4x4=
1-2-4
L
&'
TQ3-61
-BcIFU
1-8-5
I
]-1-]
).1.)
I
Ii(]
]-4-9
ALL PLATES ARE LOCK20
Robbins Engineering, lnc./Online Plus~ APPROX.
Online plus Version 21.0.012 Shear II Grain in D -B
RUN DATE, 20-APR-07
TC
BC
csr
0.03
0.02
-Size-
2x 3
2x 3
----Lumber----
SPF-#2
SPF-#2
Brace truss as follows:
D.C. From To
TC Cont. 0- 0- 0 3- 4- 9
BC Cont. 0- 0- 0 3- 4- 9
psf-Ld Dead Live
TC 7.0 34.3
Be 8. 0 0 . 0
TC+BC 15.0 34.3
Total 49.3 Spacing 24.0"
Lumber Duration Factor 1.15
Plate Duration Factor 1.15
TC Fb=1.15 Fc=1.10 Ft=1.10
Be Fb=1.10 Fc=l.lO Ft=l.lO
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
D 278 164 U 32 R
Jt
D
Brg Size
33.8"
Required
O"_to- 34"
Plus 6 Wind Load Case(s)
Membr CSI P Lbs AxI-CSI-Bnd
----------Top Chords----------
D -B 0.03 101 C 0.00 0.03
B -E 0.03 101 C 0.00 0.03
--------Bottom Chords---------
D -E 0.02 1 T 0.00 0.02
TL Defl
LL Defl
L/999
L/999
O.oon in D -E
0.00" in D -E
TRUSS WEIGHT: 9.9 LBS
0.10 Exposure Category: C
Occupancy Factor 1.00
Building Type: Enclosed
Zone location: Exterior
TC Dead Load 4.0 psf
BC Dead Load: 5.0 psf
Roof Snow Load per ASCE 7-02
Ground Snow Load 45.0 psf
Rain Load 0.0 psf
Importance Factor 1.00
Thermal Factor 1.00
Exposure Factor 1.20
Balanced Load Factor 0.76
Unbalanced Load Factor 0.00
Max compo force 101 Lbs
Max tens. force 78 Lbs
Quality Control Factor 1.25
Plates for each ply each face.
PLATING CONFORMS TO TPI.
PLATE VALUES MAY BE VERIFIED
WITH ROBBINS MANUFACTURING.
GRIP BASED ON SPF & SYP LUMBER
USING GROSS AREA TEST.
Plate - LOCK 20 Ga, Gross
Plate - RHS 20 Ga, Gross
Jt Type PIt Size X Y
D LOCK 2.0x 4.0 0.1 0.1
BLOCK 4.0x 4.0 Ctr-1.8
E LOCK 2.0x 4.0-0.1 0.1
Area
Area
JSr
0.51
0.41
0.51
REVIEWED BY,
Robbins Engineering, Inc.
6904 Parke East Blvd.
Tampa, FL 33610
REFER TO ROBBINS ENG. GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
Trusses Manufactured by:
TRIANGLE BUILDING PRODUCTS
Analysis Conforms To:
ANSr/TPr 95 & 02
Design checked for LL on BC
per BOCA (section 1606.2.3),
rBC/rRC-2003 and FBC 2004
(section 1607.1), 20.0 psf.
Refer to Gen Det 3 series for
web bracing and plating.
Wind Loads - ANSI / ASCE 7-02
Truss is designed as a Main
Wind-Force Resistance System.
Wind Speed: 120 mph
Mean Roof Height: 25-0
Robbins Engineering, InclOnljne Pius"" ~ 1996-2007 Version 21 0012 Engineering. Portrait 4/2012007241.32 PM Page 1
Left OH
o
Right OH
o
Engineering
T0704] 879
DG 1-10-1
HO 12
Scale: 0.799" = l'
Truss Design Engineer: Thomas A. Albani
License #: 077357-1
Address: P.O. Box 280055, Tampa, FL 33682
Date Sealed: 412012007
,------ -------~-----,----------,----, ------
j
PLATE LOCATION
ROBBINS ENG. GENERAL NOTES & SYMBOLS
ft108
I%~>
Center plates on joints unless
otherwise noted in plate list
or on drawing. Dimensions
are given in inches (Le. 1 1/2"
or 1.5" ) or IN-16ths (Le. 108)
PLATE SIZE AND ORIENTATION
3x5 II
The first dimension is
the width measured
perpendicular to slots.
The second dimension is
the length measured
parallel to slots. Plate
orientation, shown next
to plate size, indicates
direction of slots in
connector plates.
f~"" .,l
fT'TT
":,,
--.1..,[J-
.
------~-
FLOOR TRUSS SPLICE
( 3X2, 4X2, 6X2 )
f-llL_f
(W) ~ Wide F ace Plate
(N) ~ Narrow Face Plate
DIMENSIONS
All dimensions are shown in
FT-IN-8X (Le. 6' 81/2" or
6-08-08 ). Dimensions less
than one foot are shown in
IN-8X only (Le. 708).
1'--6-08-08 ----t
H708
~
ROBBINS connector plates shall be applied on both
faces of truss at each joint. Center the plates, unless
indicated otherwise. No loose knots or wane in plate
contact area. Splice only where shown. Overall spans
assume 4" bearing at each end, unless indicated
otherwise. Cutting and fabrication shall be performed
using equipment which produces snug-fitting joints and
plates. Unless otherwise noted, moisture content of
lumber shall not exceed 19% at time of fabrication and
the attached truss designs are not applicable for use
with fire retardant lumber and some preservative
treatments. Nails specified on truss design drawings
refer to common wire nails, except as noted.
The attached design drawings were prepared in
accordance with" National Design Specifications for
Wood Construction" (AF & PA )," National Desi9n
Standard for Metal Plate Connected Wood Truss
I Construction" (ANSI/TPI1), and HUD Design Criteria for
, Trussed Rafters.
LATERAL BRACING
Designates the location for
continuous lateral bracing (CLB) for
support of individual truss members
only. CLBs must be properly
anchored or restrained to prevent
simultaneous buckling of adjacent
truss members.
~
W :::; Actual Bearing
Width (IN-SX)
R = Reaction (Ibs.)
U = Uplift (Ibs.)
BEARING
When truss is designed to
bear on multiple supports,
interior bearing locations
should be marked on the
truss. Interior support or
temporary shoring must be
in place before erecting this
truss. If necessary. shim
bearings to assure solid
contact with truss.
Robbins Eng. Co. bears no responsibility for the
erection of trusses, field bracing or permanent truss
bracing. Refer to BCS11-03 as published by Truss
Plate Institute, 218 North Lee Street, Suite 312,
Alexandria, Virginia 22314. Persons erecting trusses
are cautioned to seek professional advice concerning
proper erection bracing to prevent toppling and
" dominoing ". Care should be taken to prevent
damage during fabrication, storage, shipping and
erection. Top and bottom chords shall be adequately
braced in the absence of sheathing or rigid ceiling,
respectively. It is the responsibility of others to
ascertain that design loads utilized on these drawings
meet or exceed the actual dead loads imposed by the
structure and the live loads imposed by the local
buildin9 code or historical climatic records.
FURNISH A COPY OF THE ATTACHED TRUSS DESIGN DRAWINGS TO ERECTION CONTRACTOR. IT IS
THE RESPONSIBILITY OF THE BUILDING DESIGNER TO REVIEW THESE DRAWINGS AND VERIFY THAT
DATA, INCLUDING DIMENSIONS & LOADS, CONFORM TO ARCHITECTURAL PLAN I SPECS AND THE
TRUSS PLACEMENT DIAGRAM FURNISHED BY THE TRUSS FABRICATOR.
6904 Parke East Blvd.
Tampa, FI 33610-4115
Tel: 813-972-1135 Fax: 813-971-6117
www.robbinseng.com
301_0" 301_0"
5'-4"
7'-9" 7-4"
101.411 4
-5"
Cc
NOTE: VERIFY BILCO DOOR
A I r — , I DIMENSION AND GRADE
1 1 LOCATION PRIOR TO
A 8'I 4' 11 1 I POURING CONCRETE
8
I I I
BILCO DOOR
HOLDDOWNS
�l I 1
GALV. MTL. AREAWAY A5 r 4" P.C. ABOVE I I
3'-0" X S-O"X4" REQUIRED BY GRADE
P.0 SLAB3030— (TYPICAL)
G_0, G-8" 2)2"X8" I
r - - - 5L.G .DR. 4" DN. 3046 - - - TYPICAL FOUNDATION9 OF
�� " 8" P.C. FND WALL ON 16"x 8" P.C. FTG., (U.N.O.) 1 r - - � - - - - - - - - - - - - - - - - - - - - - - - - 'J I I O
„ (2)2 X8 2' x 4" CONT. KEYWAY, (2) 2"x 4"TREATED SILL I _ m
PLATES, SILL SEAL, TERMITE SHIELD AND I 1 1 P NINGI 1 SECTION ^; n
DAMPROOFING BELOW GRADE. p 1 CELLAR
D.W. 7) I I DETAIL A ^ ' —
DROP TOP OF CONCRETE AS SHOWN. -"q' I 4" P.C. SLAB V! —
co ' KITCHEN /' I NO E: DROP TOP OF
4 4 0 51MP50N OR EQUAL HOLDOWN5 TO BE 1 }�
I CO CRETE I I " AT E
3'-4" i 05'-0° D AREA _J PROVIDED AT CORNERS OF BUILDING AND AT I I 5H DE 1
Q OPENINGS GREATER THAN 6'-O" WIDE. / � 1 — 4"
. .-0/ ro 1 I G'- 10ll 1110" 1—Al8 V V g $
N N cn
w/D v TYPICAL ANCHOR BOLT \a > m
I
nr ---- --- - -----J
5/6"0 x 5-0 O.C. WITH MINIMUM EMBEDMENT 1 1 — r w
U OF 7" WITH 3" x 3" SQUARE WASHERS, HOLD 1 2" — -� — _: I I >
O ^ CL ___—___� ___ CL___ OFF CORNERS AND 4" TO 12" OFF EACH END OF I I 1-24" 8" O I G V
0 N 2 2" X 10" V EACH SILL PIATE. I 5'-0" IGH 3 I/2" DIAM. STEEL — J
C. PEP COLUMN - — CC�CCySS
O N I W/ 30"X30"x 12" NI MECHANICAL I I
" O 7'-0" 4" 12'-0" ° i P.C. FTG.
N p NOTE: FIRE PROTECTao
I I
NG AT HTR.
O 3 m I O W/�5/8" FIRE RATED P. I I
m GREAT ROOM 9 I/2 WI40 FLOOR JOIST —
GYP. BD. A5 PER I — _
BEDROOMS x o 0 1 I 0 @ II 2" O.C. CODE I I N+
S.D. O_ N m i 1 I i\l 1 I I i ±24" 8"
OOD
NN 1 O rh / r1 I m di x 5'-0" HIGH
x 2i° 00 \ � I I ip C9id _ C. PIER b
4" 0" 5'-0" 4" 4'-5" 4'-7" 4 5'-2" G" NOTE: SOLID BLOCK I j a',o I 1 I v
WALLS F(OR FUTURE I 1 IDii f L _I_ J
ATTIC ACCESS `r GRAB BANR5 AT TUB xjr
v DBL. FRAME urn /5HOWEER AND TOILET. I - ig m
OPENING AT g REEFER TTO DIAGRAMS
N. I FOYER - ------ 2° o oo ONDRAWdING #2 o I I -1 I j Y
O �. .ILL. C.0. 5.D. � a m°u �'' _ 4'q 11 7-8 5 -4 — 15'_8° I V
— � a I I
- - " F W I m�
L - - - - - - NDTE:
C „ ° " G'-2" — I FLUSH GIRDER TYP. - 1 1 m
-' 2'XIO' — J n 4-7 _ 5-2 n V O lru�:
L - - - - - 1r -4iiWALL I/ Wx -- - -2 SD (REINFORCE FO G B BAR)3° INS. W5 DOOR �-B
N � L J RACE COL.NOTE: LEVER HANDLE
HARDWARE ui '-8" 1 21_4" y. 89 I
o / \
PORCH 8" I _ 9 I/2"WI40 FLOOR JOIST 1 I
1 4" P.0 SLAB DECORATIVE MASTER BEDROOM = 10
RAIL o O I� @ 16" O.C. I Q
1 (2) 1 3/4^ X 9 1/2" LVL DROP_ _ _ ROOF TRU55 GIRD R_ K� — — — — —
� — — — — — — — — — — — — 4)2"X4" WOOD ROOF TRU55E 4)P05T 8" CHEEK WALLS P CHEEK 1 1
POST 24 O.C. SOLID � ♦
WALL UPI L _ __ _ - - -
G. @
1 2-G 50LID (2)2"X 10" 7 4" WOOD FRAME WALL O 2: 1 MAXI 1 y
- - - (3) 3046 MULL � - - -- - - - --- - -- - - - - - - - - J
L — _ _ J I G" x I " TYPICAL CORNER HOLD
A REINFORCED WALL P.C. PIER / DOWN DETAIL SHEET X 3
G" X G" LOAD BEARING P05T .Z FOR GRAB BAR /� PHD5
W/TRIM OVER 4,-G" 3'-2" 8'-G" 8'-G" 8" P.C. FDN. WALL (EITHER E DEEOF OLDDOCORNER
(PROVIDE GAIV. MTL. 2
POST BASE 4 CAP ON 16" X 8" P.C. FTG. —— — — — — —
ANCHORS. 5IMP50N OR EQUAL) T-8" 5'-4" I T-0" DROP CONC. 11" T-8" 5'-4„ I T 0" P05T)
AT SHADED AREA
8" P.C. FDN. WALL 0-0",
30-0„ ON I G"X 8" P.C. FTG. � 3 0
z 0
FOUNDATION PLAN a-
a� m
SCALE: 1/4" = P-O" 00 N
FLOOR PLAN g a O
u- o
SCALE: 1/4" = I'-0" z QC
8'-0" CEILING. HIGHT COTTAGE FLOOR AREA: 1 100 S.F.- �VrR � U —
Oz tn
c
PRE-ENGINEERED FRAMING NOTES : NOTE:
ALL FLOOR JOISTS REFER TO GEOI.GIA PACIFIC WI SERIES O= � N
I . PRE-FABRICATED FLOOR JOISTS TO BE WOOD I-JOISTS AS NOTE: AT LEAST ONE WINDOW IN EVERY BEDROOM 2_` _ _ 2, 0 w u
MANUFACTURED BYTRUS-JOIST OR EQUAL. USE ONLY TO BE EGRE55ABLE AS PERTNE FOLLOWING: PRE-ENGINEERED FRAMING NOTES : 2 r 2 21'I 2111 2'I— z;j
SERIES INDICATED OR BETTER.
1 . MINIMUM NET CLEAR OPENING WIDTH 20". T I FAI
2. JOISTS TO BE INSTALLED IN STRICT CONFORMANCE TO 2. MINIMUM NET CLEAR OPENING HEIGHT 24". I . PRE-FABRICATED FLOOR JOIST3 TO BE WOOD EJQIST5 AS wvc• 5 Dk W. date: 4 / 18/ 07
MANUFACTURERS' SPECIFICATIONS AND DETAILS, INCLUDING 3. SILL HEIGHT NOT MORE THAN 44" ABOVE THE FLOOR.
BUT NOT LIMITED TO BLOCKING, BRIDGING TEMPORARY AND 4. MINIMUM CLEAR OPENING AREA 5.0 SO. FT. MANUFACTURED BYTRUS-JOIST OR EQUAL. USE ONLY 2" proJ.# 05.236 R
SERIES INDICATED OR BETTER
PERMANENT BRACING, REINFORCING AND MULTI-PLY MEMBERS. AT GRADE FLOOR OPENINGS) 2. JOISTS TO BE INSTALLED IN SRICT CONFORMANCE TO 2 3M1" 2
c.o.1 Ic.o.
HOLES AND NOTCHES TO BE CUT ONLY AS PER MANUFACTURERS' MANUFACTURERS' 5PECIFICATDNS AND DETAILS, INCLUDING 3" 3 drwn. b NF
REQUIREMENTS. BUT NOT LIMITED TO BLOCKIN's, BRIDGING TEMPORARY AND cc.o.l y
PERMANENT BRACING, REINFCKCING AND MULTI-PLY MEMBERS. CO Co chkd. by: DK
TO AN APPROVED
HOLES AND NOTCHES TO BE (UT ONLY AS PER MANUFACTURERS' 4 SANITARY SEPTIC
REQUIREMENTS, 4" C.I.H.T. SYSTEM
sheet no.
SCHEMATIC PLUMBING RISER DIAGRAM c-��`
roc' A,
N.T.S. Y m I
S
27; OF
F N
WOOD ROOF TRUSSES TYPICAL ROOF CONSTRUCTION
@24 O.C. FIBERGLASS ROOF SHINGLES
15 # FELT
12 1/2" PLYWOOD SHEATHING
ROOF TRUSSES @24" O.C.
6 R-30 INSULATION
1/2" GYPSUM WALL BOARD
REEFER TO DETAIL DHEET#3 TRU55 GIRDER
FOR CONNECTION (DE51GN BY OTHERS)
TOP Of PLATE TYPICAL EXT. WALL CONSTRUCTION z CJ J
R-30 2) 2" X4" PLATE (2) 2"X4"
R-30 /2" GWB. PLATE (TYPJ
2"X4" WOOD STUDS @ I G" O.C. ap
R-13 BATT INSULATION cr)
_ KITCHEN CL• BEDROOM BATH MASTER BEDROOM 1/2" PLYWOOD SHEATHING
1 5# BUILDING FELT 1 I_6`II � o
' CEDAR SHINGLE5
R-I3 INSULATION R-13 INSULATION � n 9
5/8" PLYWOOD SUBFLOORING ww� _
( T*G ) OVER FLOOR J015T W �1 ♦ ^
COO 0
A5 PER PLAN
TOP OF CONC. y� 10
NOTE: DROP TOP OF--,, I �: '" (� • Q4 u
CONCRETE I I" AT ` 4„ (2) 2"X 4" TREATED 81, (2) 2"X 4"TREATED R- 9 INSULATIO ♦ a
SHADED AREA SILL PLATES W/ 5/8" SILL PLATES W/ 5/8" U V
DIA. ANCHOR BOLTS DIA. ANCHOR BOLTS CELLAR
3'-0" o.c. NOT ; @ O 8" P.C. FDN. WALL 8" x I G" • �+ > m @ 3'-0" o.c. NOT P.C. FTG. w/ DAMPPROOFING U
MORE THAN V-O' MORE THAN I'-0" 3.50 " DIA. STL. - v .2
FROM ANY CORNER FROM ANY CORNER COLUMN �') =
TYPICAL FOUNDATION `V .22 �
rn
4" SLAB WALL CONSTRUCTION
TOP OF SLAB
8" P.C. WALL ON I G"X 8" rA `^
P.C. FTG.
30"x 30" x 1 2" DAMPPROOFING O O
P.C. FTG. (fYP.) (2) 2" X 4"TREATED SILL PLATES m m
5/8" 0 X 1 2" ANCHOR BOLTS
SECTION DETAIL A SECTION A FROM NYCORTMORETHAN I'-0"
FROM ANY CORNER
TERMITE SHIELD
SCALE: 1/4" = I'-0" SCALE: 1/4" = 1'-0" 2
V
BLIND FLA5HING,, IBERGLA55 ROOF 5HINGLE5
LOCATION Or SOLID BLOCKING
FOR FUTURE
GRAB BARS
a
I,' I
GRAD D1AR REINFORCING DETAILS
117I II II ,iJ''. 4'
JLIu J-u CO)
Hill ® I1 'I
W
OVAL DECORATIIVE VENT
u iIJ Llu L Lr -Il �gll �( �E J11� JL L TOP OF PLATE
111 LI �i LIL:J, II I_ IJ, ��yy �-I;II 11I1 1It111 II IJiI III
ll 'ill 11 1. ' rl, " I_II I ILIIIJ:I, 'I lltlJ I I
JI J I; 1 lIJ III L1 J it
l 'll 'I I' ; IL II I' ll II IIII ,L ILLi 4" CORNER 0
LI IIl IIII LIIll Lill BOARD V
I111. �`❑ �N, LI .'�I II I I I '� I I Ll..il'I ! it llll ll,l,1 =
I I- ��l '' IIII JI I. ICI I11 ' II I I TRIM _
G"X G" LOAD BEARING POST Ll D.
-I ;II IIJ I, JTL.IL 1. J�tL.Ii. ljl
W/ TRIM OVER I I I
(PROVIDE GALV. MTL. IIII 111 I_ ll II l, Il 'I Ili
POST BASE E CAP
ANCHORS. SIMPSON OR EQUAL) II ''I. JI _Il'. iy II I111111 -II rl .'. lJ I1 'J
I_ - LIL -'I- 111' I�I_L LII - I ' L11' 1II I�JI fl TOP Of5UBF
2" MAX.STEP UP — _
3° DECORATIVE
RAIL
I I I
I I o3
I I I 1
- - — L I L O
I — _ I
l — 1 TOP OF SLAB
— — — — — — — — - - -
H
HID
Lu
FRONT ELEVATION z o
00 _o
SCALE: 1/4" = 1 '1 Ga >
� m 4)
IBERGLA55 ROOF SHINGLES IBERGLA55 ROOF SHINGLES
1 LOUVERED
SCREEN FIBERGLASS
LOUVERED VENT 1 12 G
18 X 24" SCREEN I fIJ�441L, i � Of SHINGLES date: 4 / 18/ 07
"Ij�i rllltl }tit LOUVERED VENT - u '�jii if 11 IJIlh li Il
sI I, {Ir 1 I FIT III :II
L I; 11 l+tl i 11 II Ir II 12 ylt l;a tll`rjzl "'IIII lr r r = prod.# 05.236 R
ll ul 4� IA1 Ih! - III, �G fl r.Ip JrIJI 11LI1 � 14t1
_ 'I ld hIIJ C � I I 11'��I+11i Illlllilf ¢ 'i L Ll JIJI {11/LIL yII .II I_lI�+ ;'I Iles I ,
i111ii I m'.l' PI II II'� IIII ,'�� I h , _,„ l,ru�' ._ _ f lr I'II"i li CiflII�LI, �' �IT(LVl �I f1411'I�II - If�'If111
1 1 41I IIJI
(I!J1ui Df Ir,rII I l- ,J . J II TOP PPLATE —
9�,} 1 kN „ u I1 l 1 1Li J Yr'I [.
' lua -",lu �' , Itul �;I �I! I III`II,L II. LII rI I' n r1p _ TOP OF PLAT IViII LrFIh y II_I` I111GIIlI rrl Jt Iff h'
r u ' J ,I yll ',.,. �Oi l` IJIII II I. �.�Iyt�i,lY. �u11,�I1¢L II C111 I,Ir7l!�IIp _ .� i. II '.I.,I f:yJ lLll l',L I, I ° II }tlIII"'�II� it pl ih�110 �,.�
. yl„ I� u I. Id,I}.r Iylo,�,uI,11IT1- ul lift- IL
`p if Ir ' .„' 'r,�t,l itL� w'u�41 I: I, I11 .rl:l 1 r Ir drawn. by: NF
Ilrlir. ll J.t IT
nI:J r u1�,Ll r[,4i 11J [G, li�":- L khrlu Jil IIII IaJI I-1�i7 'i III; 1 I � 'Iul
u� ul JIl:I! IILpII F,en, ; '.� :td rlll Yf If1sI:l IL ICI�I. I,' LLC.,n 'J " I:'rilu fh9 :l.l' - ijil.'�r 'h , �
f111 a}y�,Il] I,, {�.IIlh}III' ` I,n�llI l',lla 'L,1�111f 111Ir II16 � f ';1:
I11�-'aI_,_)_�1 �d iL,I lx 111':L• J 1,J�.y1111- 111-u liJ,n l-�y l�r'1L I�'I- JJ„1IS � IIY,I , L �G:fljl rlli, rl: f II1, II,FI - } I7L 41 ?I Il CHkd. by: DK
III II hnI w {"W:- .J.lil ;111I IJ plll lI-u :II,:;IIII' - ',lu ® p'Ji.SII fl ILIT II IC',',„ '111,;_- ' �'' '� . I; r l - "11I aI I � I' �' I ..:,if lil 4 �t� 11t II, , III r r s
! �ar' II11'11-, !'V' kill l'f I rrl Ll li,iili111 l}I II',{,al�� lQ $ a , ,i:.e niL,J,rl- ® ,QIli .11�h l'1�.Ii��, �II�JIiII I''�fl y' IJ'�ILI IIC!I f.�l�l I11i'Ir it l�i lil l7',1:1111� t y;�II,IIIII�I'I` .l"�I�11 rt
y ..S I ti' ' "r f- '.i II b:IIl .uu l :u J111 r1 iLI 11 J,,1 c�, :. II'IId I , 'I , I .,��ry�l: l TII,I iIl , hL',' r
.II I� �� r�'r `,P I�I'I lIi4 II I}II �-�I�i,IJI l I'i,'J'u]; '�[L I- 4yli; �IIlI 71:Li.,,1il fls u .11 l' IChi:11 ' I' u I,I'7, II�ILI;I n
II I .: I .II ILL ; Il + r „ r r I J! p.,lIi t�` 1
I � o-v r , y ,J11 I.f1 -S ' 71 Ll.a It III I ' :�IJ TOP FSUB_ FL. {' {'Irl ,..i r,4,'117.Tut}'
U u"1 qJ"ul}I_i I,J JIT , Irl ,u!{JuV,JLIII II yI_IIY,If „I'_1_J,ly,( '11, I !_I ��_Ni'.IIJ I, TOP Of SUB FL. _ _ ".�� ' � � �.
IT]
BILL _ `^
I �I � - GAREAWAY �_-_-�' III I 11 �•� - � Sheet n0.
AS REQUIRED `v
(iYP.) s \ "�'�
1 TOP OF 51AB TO OF SLAB
1 2
LEFT SIDE ELEVATION REAR ELEVATION RIGHT SIDE ELEVATION � I
r/
_ " SCALE: 1/8" = P-011 TF�� NEB Q�- OF 4
SCALE: I/8" = I '-O" SCALE: I/8I, — I -0 --
I. ALL CONSTRUCTION 15 TO CONFORM TO N.Y.5 AND LOCAL BUILDING CODES. EGRE-9 WINDOW SCHEDULE
2. ALL PLUMBING 15 TO CONFORM TO LOCAL AND COUNTY HEALTH REQUIREMENTS.
3. ELECTRIC 15 TO CONFORM TO LOCAL N.E.L.AND UNDERWRITERS REQUIREMENTS. (ALL SLEEPING ROOMS
4. CONCRETE 15 TO BE 3000 F51 MIN ON I TON P5F. SOIL BEARING CAPACITY,
VERIFY. CONCRETE FOR PORCHES, GARAGE SLABS#EXPOSED STEPS TO BE REQV CLEAR OPENING PROVIDED O.FJ
3500 P51.
5. DOUBLE FRAME AROUND ALL OPENINGS AND UNDER PARALLEL PARTITIONS AND RESIDENCE PROVIDE HANGER AT EACH FLOOR
BATHTUBS MA5TEREDROOM 1 5.0 1 5.48 TRUST,
G. NOTIFY ARCHITECT OF ALL CHANGES. THE ARCHITECT SHALL Nor BE BEDROOM I 5.0 1 5.48 PLYWOOD 5UBFLOOR WIDTH BASED ON TRU55
RESPONSIBLE FOR ANY CHANGES WITHOUT NOTIFICATION. AS PER PLAIN CONSTRUCTION 51MP50N OR EQUAL.
7. DO NOT SCALE THE DRAWINGS. MINIMUM FLOOR LOAD CAPACITY 775#.
8. ALL FRAMING LUMBER(JOISTS. RAFTERS. HEADERS,GIRDERS, AND STUDS)TO BE
USE ALL NAILS AS SPECIFIED BY MFG.
HEM-FIR No. 2 BETTER.
9. TECO CONNECTIONS REQUIRED AT ALL FLUSH STRUCTURAL LOAD CARRYING
CONDITIONS. rMiNIMUM
ONE WINDOW IN EVERY BEDROOM
I O. PREFABRICATED FIREPLACES AND FLUE5 TO BE U.L. APPROVED. BLE A5 PER THE FOLLOWING: ) 1 Old
NAIL(SIMPS EACH
or EQUAL)
1 1. INSTALL SMOKE AND CARBON MONOXIDE DETECTORS IN ACCORDANCE (8) I Od NAILS EACH END
1 2. EXHAUST FANS TO E 50 ofm MIN.REQUIREMENTS.WTH ALL MUNICIPAL AND 5TATE 1. T CLEAR OPENING WIDTH 24 (TOP PLATES TO STUD
13. ALL RAILINGS, INTERIOR AND EXTERIOR TO HAVE BALU5TER5 TO BE T CLEAR OPENING HEIGHT 24".SPACED 50 AS NOT TO ALLOW PASSAGE OF A SPHERE 4"OR MORE NOT MORE THAN 44"ABOVE THE FLOOR.
4. MINIMUM CLEAR OPENING AREA 5.75Q. FT.. CONNECTOR /2 NAILS I .
(5) I Od x I I/2" NAILS IN PLATE
IN DIAMETER. I SQUARE FEET AT GRADE FLOOR OPENINGS)
d x I I/2" NAILS IN STUD
FLOOR TRUST HEADER AS PER PLAN (5) I O
NEW WINDOW AND GLA55 DOOR STORM PROTECTION: AS PER PLAN
CON5TRUCTION NOTES (120 MPH BA51C WIND SPEED,WITHIN ONE MILE FROM R5P4 (SIMPSON or EQUAL)
SHORELINE).
ALL NEW WINDOWS AND GLA55 DOORS SHALL MEET TOP AND BOTTOMSTUD. O
I. CALCULATION VAUD UP TO 5,999 DEGREE DAYS. THE REQUIREMENTS OF THE LARGE M155LE TEST OF TYPICAL FLUSH GIRDER/JOIST CONNECTION AT FLOOR CC3 N
2. CONFORMANCE CERTIFIES FOR ZONE I I B. A5TM 1996 AND OR A5TM E 188G.
Si N.T.S. TA
3. FRAME WALL5, FLOORS, AND CEILINGS TO HAVE APPROVED VAPOR RETARDER OR
1.4
(PERMEANCE RATING OF 1.0 PERM) INSTALLED ON THE WARM-IN-WINTER 51DE CONTRACTOR TO PROVIDE PRE-CUT 1/2"PLYWOOD PANELS r~ con 0 n
OF THE THERMAL INSULATION. TO COVER THE GLAZED OPENINGS(SCREW INTO TRIM OND).
4. WINDOWS AND SLIDING DOORS TO HAVE A MAXIMUM AIR INFILTRATION RATE PRE DRILL EDGES AT 9"O.C.TO ACCEPT 2 1/2"#8 WOOD (5 1 2 I NAILS EACH
or EQUAL)
Of 0.3 CFM PER SQUARE FOOT OF WINDOW AREA. SWINGING DOOR5 TO HAVE SCREWS TOP AND BOTTOM. (8) Od NAILS EACH END w �`
A MAXIMUM AIR INFILTRATION RATE OF 0.5 CFM PER SQUARE FOOT OF PLYWOOD PANELS TO BE MARKED FOR LOCATION AND C520 S
STORED ON SITE. TRAPS,STUD TOCIS 'i
DOOR AREA. STUD 16"O.C.(5) I Od NAILS
5. INSULATE SKYLIGHT SHAFTS R-19 MINIMUM
G. DOORS, FRONT, SIDES, IN51DE OF GARAGE: U = .40 MAX. SAFETY GLA55 REQUIREMENTS @EACH END.(42" LONG
7. ALL FIREPLACES TO BE PROVIDED WITH A DAMPER FOROLIT51DE COMBUSTION MIN.) U C S
AIR 1 50-200 CFM FLUE TO HAVE TIGHT SEATED DAMPER: MAX AIR LEAKAGE 20 SAFETY GLAZING REQUIRED AT THE FOLLOWING LOCATIONS: O u N
CFM. FIREPLACES SHALL HAVE TIGHT-FITTING NON COMBUSTABLE 000R5. r/A U n
8. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO SUBMIT THE SIZE, ANY GLAZING IN ANY TYPE OF DOOR.
V�
DESIGN, AND TYPE OF MECHANICAL SYSTEMS WHICH WILL BE USED IN 2. GLAZING IN ANY WALL ENCL05ING ATUB,SHOWER
SUFFICIENT DETAIL AS REQUIRED BY THE BUILDING DEPARTMENT. SAUNA, OR STEAM ROOM.' TYPICAL HEADER OPENING VJ �"T 8
9. ALL THERMOSTATS SHALL BE ADJUSTABLE 55 DEGREEW TO 85 DEGREES F. 3. ANY WINDOW WITHIN 2'OF A DOOR.'
4. ANY INDIVIDUAL PANE OF GLA55>9.0 So.FEET 9CAG8: N.T.S.
0. INSULATE ALL DUCTS AND PIPES PS REQUIRED BY CODE. WHERE THE BOTTOM 15 <18"ABOVE ANY FLOOR
1 1. H.V.A C. CONTRACTOR TO VERIFY HEAT L055 CALCULATIONS WITHIN 3'Of THE WINDOW.
12. CELLAR/BASEMENT DOORS TO BE INSULATED. 5. GLAZING IN WALLS OF INDOOR POOL5,HOT Ti
13, THE ARCHITECT CERTIFIES THAT TO THE BEST OF HIS KNOWLEDGE, BELIEF, SPAS WITHIN 5'OF THE WATER. ' J1 n 10 n'
AND PROFESSIONAL JUDGEMENT THE PLANS ARE IN COPLIANCE WITH THE G. GLAZING IN STAIRWAYS AND LANDINGS WITHIN 3'-0'
ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE HORIZONTALLY OP A WALKING SURFACE.'
(MAY 2002)
THE APPLY If THE
ENERGY NOTES OF THE GLA55 5 MORE THAN 60'ABOVE THEOTTOM FLOOR EDGE
AP*PA WOOD FRAME CONSTRUCTION 1995 EDITION
FASTENER SCHEDULE FOR STRUCTURAL MEMBERS
DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE SPACING OF FASTENERS
OF FASTENER CAP SHINGLE OR
ROOF FRAMINGTER (SEE PLAN) FRAMING NOTE CONTINUOUS RIDGE VENT
RAF TO TOP PLATE, TOE NAILED NA PER RAFTER Y
CEILING JOISTS TO PLATE, TOE NAILED NA PER JOIST PROVIDE SHOP DRAWINGS OF ALL
ROOF TRUSSES WITH LAYOUT PLAN. 0CEILING JOIST TO PARALLEL RAFTERS. FACE NAILED NA EACH LAP
CEILING JOIST, LAPS OVER PARTITIONS, FACE NAILED NA EACH LAP ROOF TRUSSES AS PER PLAN
FRAMING NOTE#I
CO CKING TO RAFTER, FACE NAILED
NAILED NA PER TIE ROOF TRUSSES TO BE DESIGNED IN
BLOCKING TO RAFTER, TOE NAILED 2-1 G EACH END CONFORMANCE WITH RESIDENTIAL CODE OF
RIM BOARD TO RAFTER, END NAILED 2-1 Gd EACH END
NEW YORK STATE SECTION R802. 10 AND Q
ROOF RAFTERS TO RIDGE, VALLEY OR HIP RAFTERS: R802. 1 1 .
TOE NAIL4-16d k PROVIDE SIMPSON 'H 10'TRU55 TO PLATE
CONNECTOR WITH
3-16d 8-8d x 1 112 TO TRU55
FACE NAIL 8-8d x 1 1/2 TO STUD
• WALL FRAMING
_ TOP PLATE TO TOP PLATE, FACE NAILED 2-16d PER FOOT
TOP PLATES LAP5 AT CORNERS AND INTERSECTIONS FACE NAILED 4-1 Gd EACH 51DE IN CONFORMANCE WITH TABLE 802. I . (�
STUD TO STUD FACE NAILED 2-1 Gd 24" O.C. (TRU55 FABRICATOR TO VERIFI� W
HEADER TO HEADER FACE NAILED I Gd 16" O.C. ALONG EDGES AND 0
TOP OR SOLE PLATE TO STUD, END NAILED 2-16d/3-1 Gd PER 2x4/ PER 2x6 CONNECT PLATES TIE
EACH STUD V
WITH 51MP50N H8 TIE Q
BOTTOM PLATE TO FLOOR JOIST/ BAND J015T FACE NAILED 2-16d PER FOOT
STUD TO SOLE PLATE, TOE NAILED 3 - 8d OR 2-1 Gd PER FOOT CLIMATIC AND GEOGRAPHIC ~
DOUBLE TOP PLATES, END NAILED 2-I Gd 12" D.C. DESIGN CRITERIA CODE ANALYSIS O
DOUBLE TOP PLATES, MINIMUM 48-INCHE5 OFFSET OF END 8-I Gd V
JOINTS, FACE NAIL IN LAPPED AREA GROUND SNOW
BUILT-UP HEADER, TWO PIECES WITH 1/2"SPACER I Gd 16" O.C. ALONG EACH EDGE LOAD 45 PSI` OCCUPANCY RESIDENTIAL
CONTINOU5 HEADER TO STUD, TOE NAILED REFERENCE 5TANDAR05:
4-8d 3X3 WASHERS
SPEED 120 WOOD
CODE OF STNEWYORKSTATE
CONTINOU5 HEADER TO STUD, TWO PIECES 6d I G" O.C. ALONG EACH EDGE WIND WOOD FRAME CONSTRUCTION MANUAL, 3X3 WASHERS EVERY ANCHOR
O.C. iv
(mph) AF#PA 1995 EDITION EVERY 3'-0" O.C. @ANCHOR BOLT -
FLOOR FRAMING CLIMATE ZONE: 1 113 @ ANCHOR BOLT
JOIST TO SILL OR GIRDER, TOE NAILED 4_8d PER JOIST SEISMIC DESIGN 0 DEGREE DAYS : 5750 C520 STRAPS @ I G" O.C.
CATEGORY STUD TO SILL PLATES.
BRIDGING TO JOIST, TOE NAILED 2_8d EACH END DESIGN LOADS SC520TUD STRAPS L 16" O.C.
BLOCKING TO JOIST, TOE NAILED EACH END DECKS 40 P5F RUN UNDER SILL PLATES AND UP STUD TO SILL PLATES.
2-Bd WEATH- SEVERE STUD. MINIMUM (4) I Od NAILS RUN UNDER SILL PLATES AND UP
BLOCKING TO SILL OR TOP PLATE (TOE NAILED) 3-1 Gd EACH BLOCK EKING ATTICS 20 F5F EACH END STUD. MINIMUM (4) 104 NAILS
LEDGER STRIP TO BEAM (FACE- NAILED) 3-1 Gd EACH J015T FROST 5/8" 0 ANCHOR BOLT @ EACH END
LINE 3'-10" ROOMS OTHER THAN 5/8" 0 ANCHOR BOLT @ 3'-O" O.C. HOLD G" - 12"
J015T ON LEDGER TO BEAM (TOE NAILED) 3-8d PER J015T SUBJECT DEPTH SLEEPING ROOMS 40 P5F 3'-0" O.C. HOLD 6" - 12" OFF EACH END OF EACH
BAND J015T TO JOIST, END NAILED 3-I Gd PER J015T TO OFF EACH END OF EACH SILL PLATE.
SLEEPING ROOMS 30 P5F
2-16d PER FOOT DAMAGE TERMITE M HEAVY
SILL PLATE, MIN, EMBEDMENT 7" INTO
BAND JOIST TO SILL OR TOP PLATE (TOE NAILED) FROM HEALVY STAIRS 40 P5F MIN. EMBEDMENT 7" INTO CONCRETE
SOLE PLATE TO J015T OR BLOCKING, FACE NAIL I rd 12" O.C. CONCRETE
SUGHIT TO HANDRAILS zoo#
CEILING SHEATHING DECAY MODERATE
ROOF 45 P5F(GROUND SNOW LOAD)
G.W.B. 5d COOLERS 7" EDGE/ I a' FIELD WINTER
DESIGN 1 1 ° BASIC WIND SPEED 120 MPH In
WALL SHEATHING TEMP UPLIFT 21.8# O
ICE SHIELD TIE DOWN / FOUNDATION DETAIL N Ln
SPACING UNDERLAY- DEAD LOADS O P5F W
SHEATHING TYPE LOCATION FASTENER NEW YES Si N.T.S. ~
EDGES (INCHES) INTERMEDIATE REQUIRED DEFLECTION LIMITS:
4' PERIM 8d G"O.C. 12"O.C. RAFTERS WITH NO FINISHED Z
STRUCTURAL PANELS INTERIOR ZONE 8d 6" O.C. 12" O.C. FLOOD
LN/,P,OADI ICEILING ATTACHED 1/180
FIBERBOARDS PANELS 7/16 ALL 6d 3" O.G. Gil O.C. HAZARDS
FLOORS Ui date: 4 / 18/ OG
25/32 ALL 8d 3" O.C. 6" O.C.
GYPSUM WALLBOARDS ALL 5,1 COOLERS 7"O.C. I a'D.C. ASPHALT ROOF SHINGLE NOTE prod.# 05.236 R.PARTICLEBOARD PANELS
4' PERIM 8d Gil O.C. 12" O.C.
INTERIOR ZONE 8d 6" O.C. 12" O.C. I . ASPHALT SHINGLES SHALIL HAVE SELF- SEAL STRIPS OR BE
INTERLOCKING, AND COMPLY WITH A5TM D 225 OR D 3462.
FLOORSHEATHING 2. FASTENERS FOR ASPHALT SHINGLES SHALL BE GALVANIZED STEEL, drl by: NF
STAINLESS, ALUMINUM, OR COPPER ROOFING NAILS. MINIMUM
STRUCTURAL PANELS 12 GAGE 5HANKED WITH A MINIMUM 3/8 INCH DIAMETER HEAD, Chkd. by: DK
I" OR LESS 8d 6" EDGE/ 2" FIELD OF A LENGTH TO PENETRATE THROUGH THE ROOFING MATERIALS
MORE THAN I" I Od 6" EDGE/ 6" FIELD AND SHEATHING.
3. ASPHALT SHINGLES SHALL HAVE THE MINIMUM NUMBER OF G
ROOF SHEATHING FASTENERS REQUIRED BY THE MANUFACTURER. ( 6 MIN.)
4. FOR NORMAL APPLICATION, ASPHALT 5HINGLE5 SHALL BE Sheet no.
SPACING OF FASTENERS SECURED TO THE ROOF WITH NOT LE55 THAN SIX FASTENERS D R
SHEATHING TYPE LOCATION FASTENER PER STRIP SHINGLE OR TWO FASTENERS PER INDIVIDUAL SHINGLE. ��ti
EDGES (INCHES) INTERMEDIATE 5. ROOF COVERING MATERIALS ( SHINGLES) SHALL BE DELIVERED IN _
STRUCTURAL PANELS 4' PERIM. EDGE ZONE 8d COMMON NAIL •6" O.C. • 12" O.C. PACKAGES BEARING THE MANUFACTURES IDENTIFYING MARKS.
INTERIOR ZONE 8d COMMON NAIL •6" O.C. • 12" O.C.
t 4" FOR ATTACHMENT OF ROOF SHEATHING TO GABLE WALL5. '
3
'9T�oOA 3D�y0�- OF 4
CIS o
NOTE: Fn k^
1 . ALL LIGHT SWITCHES, ELECTRICAL OUTIET5, ^�
AND ENVIRONMENTAL CONTROLS TO BE PLACED IN W
ACCE551BLE LOCATIONS AS PER THE FOLLOWING:
OUTLETS : 1 5" A.F.F. MIN. r — l A
SWITCHES AND CONTROLS: 48" ABOVE FIN. FLOOR MAX.; r ♦T-0�
4G" A.F.F. MAX. OVER AN 08
OBSTRUCTION ( KITCHEN
COUNTERS, VANITIES, ETC.). ' U
WP cd ~ f m
r - - - Y °
- - - - - - - - - - - - - - - - - - - - - - - - - - - - -
•01" - - - - - - - - - - - - - - - - - - - - - - - - - - - - L - - - i (d
qp
o
SYMBOL LIST KITCHEN / BRKFT. GP1 s.°
� 4c O
\ CELLAR
I � " I I
0 2'X4' FLUORESCENT FIXTUR Oi /,I 4 P.C. SLABE cnTv GREAT ROOM \ /
/D
STANDARD WALL MOUNTED FIXTURE
-------------------
I I I I I
'C� PULL CORD I L _I_ I
T Y
STANDARD SURFACE MOUNTED FIXTURE
BEDROOM \ I MECHANICAL
EXTERIOR WALL MOUNTED LIGHTING FIXTURE =0
I
DUPLEX OUTLET C.O.SOD,
B.D.
\ I II I I I 1
GFI GROUND FAULT INTERUFTED �� - L — J i)
ica
WPC DUPLEX OUTLET, WEATHERPROOF FOYER W
SWITCH
I I I II I
LIGHT/ EXHAUST FAN L' O
GFI' I V
s.D.� SMOKE DETECTOR s..D.
C7 l L � _ _ _ _ _ _ I I
c.0.0 CARBON MONOXIDE DETECTOR IMP
"P
TELEVISION CABL MASTER BEDROOM
L - - J
CAN E I I I
4
PORCH c
T D TELEPHONE JACK cnry T _
I I I
I I I I
L
. I
az
FLOOR PLAN CELLAR PLAN u o
N.T.S. N.T.S. G
w
date: 3 / 15 / 07
prof.# 05.23G f2
drwn. by: NF
chkd. by: DK
sheet no.
A
A N i�
w-- 4 E
OF
30-0-0
2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 9 1-11-8 1-3-0 2-0-0 240-0 2-0-0 1-10-8
0
o_
N o0 d
r
0
ao
0
N
Q
U
O YJ
p O Q
O O
O +
� C
CQ
yN3
W
O V)
H . S2ti P ) x
N Q
0V2 tTv
O
O
N v
O
T2
O N
11
O
N O N
V
U U 4
N
T7 4)
N O
0)
7o a
0 0
N
O O
O �
N
17-0-0 54-0 7-8-0
Roof Loading Account: Island Estates
Island Estates
TC Live: 30.00 psf Job 0608030
TC Dead: 7.00 pelf Designer. NONE ASSIGN
The Cottages at Mattituck BC Live 0.00 psf Checker NONE ASSIGN
Roof Truss Placement Plan BC Dead par Date:04-24-07
TC Stress Incc: 15 00
BC Stress Inc: 15.00
Spacing:2-D-0 o c.