33097-Z
FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-32844 Date: 01/25/08 THIS CERTIFIES that the building HEATING SYSTEM Location of Property: 725 HOLDEN AVE CUTCHOGUE (HOUSE NO.) (STREET) (HAMLET) County Tax Map No. 473889 Section 110 Block 5 Lot 50 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated MAY 21, 2007 pursuant to which Building Permit No. 33097-Z dated JUNE 1, 2007 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is CONVERSION TO GAS HEATING SYSTEM AS APPLIED FOR. The certificate is issued to DENNIS & SUSAN SHEEHAN (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A ELECTRICAL CERTIFICATE NO. 07-9039 01/07/08 PLUMBERS CERTIFICATION DATED N/A r Aithorized Signature Rev. 1/81 Form No.'6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the fof`lowing: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April.9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property silo wi t1g.p.11 property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent'to inspect signed by the applicant. If a Certificate of Occupancy is denied; the Building Inspector sliall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$25.00, Additions to dwelling$25.00, Alterations to dwelling$25.00, Swimming pool $25.00, Accessory building$25.00, Additions to accessory building$25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy- $.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commmercial $15.00 Date. New Construction: Old or Pre-existing Building: (check one) Location of Property: 74i�I� f4o 6 i57,j�Ayl-ip-- yF5 House No. Street Hamlet Owner or Owners of Property: 17 ;,.,. :`c 5 G- SA Suffolk County Tax Map No 1000, Section Block OS> OO Lot c $—�, oe:-o Subdivision Filed Map. Lot: Permit No. Date of Permit. L Applicant: Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ S _.7 3G _Z�pplicant Signature c 0 VY IN, MM -9039 Electrical Inspectors, Inc. cerrocate Number. 07 2 1 308 Eat MeadowAvenue X Munic4laU�-' Southold,Town Of Z' East Meadow,NY 11554 Office.(516)794-0400(631)396-7474 I-Rcct0r,- 124 Fax:($16)794-5854 Imue Date: 11712008 website:www.c]=Wmlinspectm.com Email:in(b@e1cotricalinspectomcom Mail To: PropatyAddress: Keyspan Energy Solutions,LLC. Arthur D.Conner Derinis Sheehan 125 Schmitt Boulevard 72Violden Avenue Farriiingdale,MY L 1735 Cutchogue.,NY 11935 License#: 4451 ME ELECTRICALAPPROVAL CITURTIFICATE ON A AREAS LISTED BELOW ARE APPROVED BY INSPECTION X1 .".jj AND FOUND TO BE IN COWLLANCE WITH TBE NATIONAL ELECIRIC CODE 3: No visual defiact;were found for the electrical inspection provided.No obvious unsAtisfacwry condiWns w=found in the areas h ein below only- 4W Residential Inspection Basement.Gas Burner Onty J-Wrcik J-hreal Fractional Motors. Not valid un signed by autAzd Ell Agent > ............. Richard M.Bivone Philip F.Goebring President Chief Electrical inspector W.- N !2 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 33097 Z Date JUNE 1, 2007 Permission is hereby granted to: DENNIS SHEEHAN 725 HOLDEN AVENUE CUTCHOGUE,NY 11935 for CONVERSION TO GAS HEAT SYSTEM AS APPLIED FOR at premises located at 725 HOLDEN AVE CUTCHOGUE County Tax Map No. 473889 Section 110 Block 0005 Lot No. 050 pursuant to application dated MAY 21, 2007 and approved by the Building Inspector to expire on DECEMBER 1, 2008 . Fee $ 200 . 00 / Authorized Signature ORIGINAL Rev. 5/8/02 SUFl--._ ClrwUNTY DEPARTMEM OF KEAUN SERVICES Sl4Gi4fXAlLY OY4,EW?K-ONLY H.S.REF.140, Sj=� TW wwag-dispaal arrd watar s.-jppte Willtics(Gr th.-s I(Xaqnn kaw been inspultid bj,Mis D.paiimeiitgnVor Lxi,,c-r to IoM,secusfe—try. r f/ ,;�tir•':v;'4�1 ` � G11aP E��roaD cd 6Uasterz{es Mr1 �- � _J /15 'jI 42: L? C.'2 0 Qy A ;lL 5p, 1 n .r �u pkt, *$-aj 75 TJfE An. !I 0:09D.0 AIr.NO,9HOWN AE AOT GOA RA'4799D.. E&SrVICE CF nlfNr Or WAYS AAD,'Oq EjASE"VM.Or W 7Hi5 gtmvEy vAt Pnrpmlirl IN ACCOP.Dlk�m%wrH21-4;teisriRl c*:)r OFPru.,'Tv.-tsop i-x4r,sAVEYS AVCF'ICCI tre THE rdE' T09K BTAYE On ADGi7iGIJ TO TNtS UP.YEY N 2 0 THE I EY YORK lT'5WUGA!lON LAY?. CCPIES OF T ;0 r SEAL SHALL. tA.�AVALADPRUE l0kCr'AyNrrHERqOH SHALL WN CKY 11GINE P�-RSOZNrOR WHOM 0,7-PY.URIVINSAF F'YllAD4 'r COMPAN GOVFlkk)4t KTAL AGE N"AWL1 LF.%tlfWC KiTl"O 4 LISTED HFF;CON AND707HE AS3!OUEESO,--FHC�E kla C fS-n7u-,IDfl.c6 calcAss ARE 4uvriQjImt u4sn74•n0ms arlsuusEQtjEjij owrigjIg ;Ur-rOLK C,0UrJTV 'FAX f"rl- 0 Is 7.fAGo sra-r. 00 Lq�K. LOT 60 ?IA P N C3. r-A T rl I nAp CP csvr nPq A c): ERTIFIED'YO- MAT "311 CIA 14c,R—,m OF SOUjyo�o o 7 courm,��' TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING v�FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: v DATE 1�( � _ D INSPECTOR ` FIELD INSPECTION REPORT DATE I COMMENTS C�ro FOUNDATION(1ST)------------------------------------- l� 0 FOUNDATION(2ND) trJ Z O Ul� H ROUGH FRAMING& trJ PLUMBING INSULATION PER N.Y. STATE ENERGY CODE' S FINAL ADDITIONAL COMMENTS N-� O � Z rn �7 H Oo Z �H x d ro ' H TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 3 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey www. northfork.net/Southold/ PERMIT NO. �f'301 3 12 Check Septic Form N.Y.S.D.E.C. Trustees Examined ,20 Contact: Approved ,20 Mail to: Disapproved a/c Phone: Expiration 120 09 ui ding Inspector Pil1� 2 c' J -•-�'APPLICATION FOR BUILDING PERMIT Date Ag,4y 21 sR , 20p� } INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans, accurate plot plan to scale. Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. s a J-14 4- (Signature of p)licant or name,it a corporation) Z mil. l-ud. MY I t'73 S— (Mailing address o applicant) State whether applicant is owner, lessee, agenA4'4M6tTpg4 er; general contract � c b or builder MEEK'THE REQU R�h�::'v7 5 �� � `2 :y ; �a :CODES OF Nt',M yGF44 , - nATF- 611 -7 P �,y Name of owner of remises ` FEE: _d,,- :` c'�-E%, P e-,A s See �,h . (As on the tax roll or lat eit5- �b 8 AM TO I . �OR THE If applicant is a corporation, signature of duly au1 gVERTIFICATt FOLLOWING INSPE"?". 1. FOUNDATION - T'AJ)�PE-QU'RED My(Name and title of corporate officer) - FOR POURED COt�(',?'_TE 2. ROUGH - FRAMIh,`.:. Builders License No. OCCU PAN-Y O.R 3. INSULATION Plumbers License No. 4. FINAL - CONST;?' ! MUST 3s �9 r � i �c� i��� `�A1NFU� ...:). Electricians License No. BE COMPLETE i=O!SFICATE ALL CONSTRUCTION SH"d L MEET THE Other Trade's License No. E % I ' ` < i REQUIREMENTS OF Tf;i "DES OF NEW Q� Ali�Ncy YORK STATE. NOT RU-SI- )NSIBLE FOR 1. Location of land on which proposed rk 1 . DESIGN OR CONSTRUCTION ERRORS House Number Street Hamlet Count Tax Ma No. 1000 Section //� Bloz kA�s r: b Y p �� S�' Lot � Subdivision Filed,, dp,.No. Lot , (Name) 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy. 3. Nature of work(check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work a,[ i A,A wOZ ,(Description) 4. Estimated Cost A 2 5 Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars , 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded?YES NO Will excess fill be removed from premises? YES NO 14. Names of Owner of premises Address Phone No. Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) h,l SS: COUNTY OF ) being duly sworn, deposes and says that(s)he is the applicant (Name of individu sung contract)above named, (S)He is the (Contractor, Agent, Corpor`&& �'icer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge-and belief, and that the work will be performed in the manner set forth in the application filed therewith- Sworn to before me this / day of 20 7 =-s otary Public gnature of Applicant ,10AN M. BOTTICELLI Notary Nobp�, State of W Ysau tyork -7 Qualified.piresApri 23+20�'� / Commission Exp p 6, *+ - ■■■■■■ ■■■■■■■■■■■■■■■■■■■■ ■■■■■■■ ■■■■■■■■■■■■■■■■■■■ f a�. �-tJe-,. •y •-ram.- ^4-�ts ■■■■■ ■■■���■�■■■■■■■■■■■■ S^ „C^ ' iS>:•a<V_ ■■■■■ ■■■E■■■■■■■■■■■■NONE ■■■■ _ . . . . MINMori■m M-■■911MI■■■■■■■■■■■■■ • a r ��.. ■■■■■■■��■■■■■■■■■■■■■■■■■■ Foundation :. asement !Ext. Walls Interior Finish Fire Place c Recreation-Roomi Driveway is coo - o TOWN OF SOUTHOLD PROPERTY RECORD CARD OWNER STREET VILLAGE DIST. SUB. LOT to FORMER OWNER S)q -E v ))UT*aw. N E .1 ACR. ,fit C L155 1 c�l a 4-e.a U "' %U 2a I' .J7,2 ,-CLC4 C1t� �� S �. n W / �ry TYPE OF BUILDING tE 7 SEAS. VL. FARM COMM. CB. MISC. Mkt. Value ° LAND IMP. TOTAL DATE REMARKS `7Q Q ©� o �z (rAm",JAU L �iz.3 AGE BUILDING CONDITION t 131 4)-e NEW NORMAL BELOW ABOVE I I S_ ' 5g 31 Ua l�n $- FARM Acre Value Per Value Acre (n 3 D�-l-l 013�'-F t -�A l�llV� "t"y �� l-hjvl ' Ci AO. ` n kG Tillable I Ld O- l kv) e°-CnD. -D S1')9,ph6n Tillable 2 tillable 3 Noodland swampland 3rushland FRONTAGE ON ROAD louse Plot DEPTH' , v,Ve total DOCK h �- o } � 6 1 y .. s �,r s"34.j+-d ICY, t ':' • .' � 'S ��•�1.sW.�'.% �f46i' L �.,. � ,, 4nar n y f i'i � h tr zw"5 �a'«+ � �n, a i `t,.:.`t > 'a" ,,,�s r t �` f Y B t 4' � � 4yr• � �Y�,Sr i� h ... ,.' asn 3,� •E - s dr��5s, `�k ;x , ;t'?,'S 1p MV. gn �=n Sc � �'•�` a) a arc + egx � < 32 % ��� 3�" i r��tte k-f'� Fl ti��L f t<c 'A 1 �, F3'�:, � L'" n7,.. ���.• Y S; tN`�ac[:.-`� ,a? ,[Z t�'f eu f �,"i'k� _u^• ` .r.'f�.. i'i•ri f !� sK Ek S'ff�,,..,?� s. Yin a "✓t 'u� '"6+- "t �`�`�p'�["� "•'"�•z�f.-� �s �' a —:�K-F A# .... ���s�����' d f > f $av t� L.: ✓ srsa�,�Yvx� ,S� S� �� - h k2 P ;� ` § trly�ftryQ .rF�tellrgPrll�sySre/7m .and t � V kN x.. .� . FA do � ;7-' ;:.�5���*��..<s'+,��'^s' x �.'���?X �f�t����`:�go �' "�`f'"'�, `•. K '?da'r' �'. � t �,�� s� � �, 1.' .:.�4` � a a2 - � e�R!'.;.�' � t�s v• *�K{�-��,."Y`' �'��`' �2 R��"�'Y'�"� � ak unflm ar exch4 ge&-, i t : • Y?li o e aricl ventun teshnolo' #hat cons a= . optimal:atr:and feel.ra#io'.at:allyail Ell I ININ '= '�5 V .r 3s ;a+ '� t - {E.=,~f�t t`✓n `t< � �f� f;° 5,v`` 1'� YC�.i•4 r{ u a., . 'r ` .4 � r� YES ����Y:d rf..`.se •�'� �p5...� .n. }'+a• #n''`?i 3� 7' 4'MY ����# '' __ i{":� L r�.$'~'�.>��h+'ta`4 ^�.. r�R. �&ast$SN'�u.,,�lk�,yy�,'��'��� ��� yyyf��i';�'� ;-t� K,��f. `7�,�' t• �, f� 5+; Z':y'> ? 6 _ - ';` }�,e<al, F4pf c�.3„•t%+�u 2+`n4¢+aF AF c'�..,i .a :, �.:,r. ,�.ra�`4y: ..� :" :'`:.', '... .::t„ ""�P',4:•fz�' ��" +�i` �2�� �{+ 'r'x='4�e§g�.r ..F as"zawn N 4 .. 4"�` +S ,ar :•, Lf.t"�'Lk•: �s�4 S *1'a'•`�. } �•�S�i��t. tg." ,� i+ a .w��� _ .: . . „�k�-, .�f�`diut:��.,e.�a��p�� mt�'q,%it,�;� .�s�$s<w '` i`�"Y, I '' i.. '-.;�;d Weil-McLain :: Products :: Ultra gas boiler Page 1 of 1 EAMER-MgLiffiN5 Fw—jt hott Cttt"tpi&D 1i9_oT GONSU'Pr ERS PROFESSIONALS ''M GEAR'; A80UT i Homes Professionals '^y�<, ► Products . Gas-fired boilers Ultra gas F Showcase �,• E y Distributors Only " �� �. ., I� Product Locator ► Arch/Eng ► Service Info F Pro Training 3 F Distributor Locator U It 01 w Contractor Appl. A " Highest efficiency comfort heating Models. UG-80, UG-105, UG-155, UG-230, UG- 310 r 8,FE =8f€EE3 -Gas fired water boiler with cast aluminum heat exchanger -Venturi mixing body mixes air and gas providing higher efficiency -Designed to operate in low temperature condensing applications -Outdoor reset and domestic hot water priority standard -Negative regulated gas valve precisely delivers gas to the boiler -Electronic control module automatically adjusts blower speed and gas flow rate in response to environment -Modulates with 5 to 1 turndown ratio -Variable speed motor matches combustion output to heating needs -High grade stainless steel burner features quiet operation, high efficiency, and cleaner combustion for low NOx applications ©2007,Weil-McLain I Privacy I Site Map I Careers http://www.weil-mclain.com/products/displaypro/1-Ultra%20gas 5/21/2007 WEILEMILiiIN P us and PLUS GOLD Indirect-Fired Water Heaters - � A� w GOLD Plus Residential Units 4 Sizes Models 30, 40, 60, 80 t S i.t< r t ir-"tZ �. � �Y -•°{ �� ,� +r a �S-2 � _ PLUS (/�_ "" F' Oyu fa "ar4,,,, 4y ,. 1•'3q".$-^ pf r t.�' Commercial Units tt. r rr � T 2 Sizes Ri Models 61 � vga{tea 7 F �2115 d rz�.`r k y g r r i t i ti as y,4 of -vim' uc r. AI -m r a +xt zJ rr - - a s ray gets 0 S �n 5 xa 5 � More Domestic Hot Water When You Need It UP High Efficiency - Low Operating Cost Weil-McLain Quality & Sales Support q� G-�-:Y.tit..�. _ .h�ae#•.,.,�T..r.'1.n{ �'Y...d., n.. �.�:� "r.�" k� J�' ( P F'1 ^y7}-f dY 2' GOLD Plus FEATI IRES �' WEWM IN j `''SRgd{ _sS.°�'`4ati Fx�'c �; n,� �{' �.��' s> 7`ab4"tT� }r ` �'x#�' a'��,,'�� .. .,,. � "�aif 'xz''", �:• k • , '+'';, Spud for T&P Snap Set Electrical Adjustable r Relief Valve Connector Thermostat PLUS Domestic Hot Air Vent Domestic Cold r Water Outlet Connection Water Inlet 3 �:. pemava6lePWte Cover There are six Weil-McLain indirectfired 1 ># water heaters: � �' ■GOLD Plus-Four residential units: Round Gold Plastic Boiler Return v Jacket—Protects (on Back) GOLD Plus 30, 40, 60 and 80 with Exgtenor CoROS t Dents Ordl }' round gold plastic jackets. }- 2 Inches f Rigid o ■PLUS - Two commercial uriltS. Polyurethane Dip TubeK�u �n PLUS 100 and 120 with rectangular ) Foam Insulation a a blue enameled steel jackets. 31 ; Carbon Steel � Dry Well for £F Outer Tank Thermostat Remote 7 These heaters are designed to be used Sensing Bulb } Wi Circulating with Weil-McLain cast iron boilers to pro- WIN' Circulating Bailer Water ' vide the best value combination for any N Corrugated DOMESTIC WATER - § economical and abundant supply of �`V1nnerlrankteelS& domestic hot water plus energy-efficient a comfort heating. f 7. Boiler Supply (on Back)LIM ,F . �,fx r . n ��'�^e $ C� a3 c i -re N I Furnished with 3/4"NPT Brass Tee,Drain Valve&Auto Air Venth �Nr�+��.Fe���gggg �EP1Ct�NGY ile)I�t1CLalri bollet are a al ab eat` to�8 operating.etti%e Y f 'ry ��.--- �sP2' -i�r ;,'„�a�s t �, L a 7 ..d § c HOThxWAti� lel°MCL In�lnd'rreClfl ed ters,plod Ce"tw�Ce a • r Yd Ycr� s a x a :*� f% s y N � ti . aw of ka,tank�ess4 Col(,��t�least�0°lo ere han a co par� F sizedllreire�d rasa W� ei ha�eater,three� rres sr'7" � it'�b..7ai• xa '� f - � { ' A� EASY l STA .LAOI `� a r f i �� edtplp g in d w ratheaf t ► ��an ,n g sy Tat of o Iristatlatlo: � c s NovaeSNIarN10,11le SLpte V811T. c�'��eCtf c eternents �4 � _ -K wGo GOLD oil Boiler and �� LESS>'1AINT i�1NCE � ell (vic n heater's area nulne�r ro e7e GOLD Plus 60 Water Heaterw x $ c��riherun di ; ty(recVOW atC1 sdrapaC n�ts ? t�� r . ¢� f �x atlen no calf mailltalnN no Colc spots. orh stra t do E � ' "eini�11'1�1`1to-17 �ntltrlfarlkreslgti' �or� � � t ®� steelTo to Ad K _* rilClue Ely, g s Y - kt . Mk. �,` M " 1 JnrTM`_ v� G Gln,lnsuiatipn� �� t �s --� ? Speclai Krarourtd design heat1sJaster nosCOitl spots. :r r ' ? • Low resslre cro tilnustry m t e d x�o%hl huh° V, recjulred� M; I ) ridentla ppii�at�o s v � • ve; eta l�s 1004 a beak teste s 1.:,Ir EV It IViLAl�1t�tz7 astvalu% �proc � gua��yr° a srreleC Icai S -- ' h ptlo4t �meatver Prote tirt Plan P `V(r� exte�adecl warrant+t '- rer gt I'3We NlclNater= ietesupld aits 1 s yq 4 fi �y N } "d1.Ri'f C S."oY E4 fi �.���� � o' g llfe�flmitedrtetjrpe��rran�y�,ion�'i�L�Pfi�s �sti€Ienai� GV GOLD Gas Boiler and }r 5�/� raL3i�PL�ISCOITinletCt DnftS " GOLD Plus 40 Water Heater BOILER/WATERSELECTION GUIDE - First select the boiler model/size based on design heating load. - Then select the water heater based on the first hour requirement. - For hot tubs, spas, etc.,it is suggested water heater tank capacity should equal the capacity of the tub if immediate fill is required. 30 GOLD OIL BOILER CG/CGX GAS BOILER CGi GAS BOILER WATER HEATER MODEL WATER HEATER MODEL WATER HEATER MODEL First Hour Rating-GPH First Hour Rating-GPH First Hour Rating-GPH BOILER GOLD Plus GOLD Plus GOLD Plus GOLD Plus BOILER GOLD Plus GOLD Plus GOLD Plus GOLD Plus BOILER GOLD Plus GOLD Plus GOLD Plus GOLD Plus MODEL 30 40 60 80 MODEL 30 40 60 80 MODEL 30 40 60 80 G ' £0-2 85 190 200 210 CG-25 Att0a 2A30 CGi 2500 110 115 125 GO-3 , 23 235 250 260 C5-3 0 140 150 160 CGi-3 13 135 145 155 00-4 260 310 320 CG-4 a 190 200 210 CGF4 5 185 190 200 GO-5 230 260 365 380 CG 5 ' w4 , �` 245 250 265 CGi-50 235 240 250 GO-6 230 260 365 450 CG-6 260 300 310 CGi-6 jjj1t' 260 295 310 GO-7 230 260 365 510 CG-7 230 260 355 370 CGi-7 230 260 350 360 GO-8 230 260 365 550 CG-8 230 260 365 420 GO 9 230 260 365 600 BOILEREG GAS FIRST HOUR RATING Maximum gallons of hot water available WATER HEATER MODEL First Hour Rating-GPH 1n one hour.This is the most common BOILER GOLD Plus GOLD Plus GOLD Plus GOLD Plus GV • fa GAS BOILERrating used to size water heaters. MODEL 30 40 60 80 DOMESTIC PRIORITY ,• - - EG-30 170 180 190 WATER HEATER MODEL EG-351 185 190 200 First Hour Rating-GPH When the storage tank calls for heat, EG-40 Y- BOILER GOLD Plus GOLD Plus GOLD Plus GOLD Plus =,_ 220 230 240 MODEL 30 40 60 80 boiler water is switched from the heat- EG-45 260 265 280 ing system to the tank. " GV-3 44 145 155 165 EG-50230 260 300 310 GV 4 200;F ' 200 210 220 40- NO ra' f c o EG-55 230 260 340 350 GV 5 30 260 270 280 EG-65 230 260 365 420 White-Domestic water priority and/or hot GV-6130 260 1 320 330 boiler not required EG-75 230 260 365 490 WATER HEATER MODEL NOTES: First Hour Rating-GPH 1. First hour ratings are based on: BOILER HEATING GOLD Plus GOLD Plus GOLD Plus GOLD Plus PLUS PLUS e 115°F domestic outlet water CAPACITY-MBH 30 40 60 80 100 120 supply temperature for above 115°F 140°F 115°F 140°F 115°F 140°F 115°F 140°F 115°F 1407 115°F 140°F tables •115°F or 140°F for table at left 50 120 90 125 95 135 100 145 115 160 130 210 170 •50OF domestic inlet water 70 155 115 160 120 170 130 180 140 200 150 250 185 temperature 90 190 140 200 150 210 160 220 170 230 180 285 215 •200oF boiler water supply 110 230 140 235 170 245 185 255 195 270 210 320 245 temperature to the water heater •Flow rates are for factory- 130 230 140 260 170 280 210 290 220 310 230 360 265 supplied circulators or flow 150 230 140 260 170 320 220 330 250 345 260 400 300 rates as shown 170 230 140 1 260 170 355 220 365 275 380 290 430 325 •Assumes approximately 80% usable storage. 190 230 140 260 170 365 220 400 300 420 310 470 345 210 230 140 260 170 365 220 440 330 455 340 510 375 2. If the net BTU/hr.rating of the 250 230 140 260 170 365 220 510 380 530 395 590 430 boiler is close to the space 300 230 140 260 170 365 220 600 410 620 460 675 500 heating load if there is r unusually largg ee demand for 350 230 140 1 260 170 365 220 670 410 715 510 765 560 domestic water-increased boiler 400 230 140 260 170 365 220 670 410 740 510 860 630 capacity and/or domestic priority 450 230 140 260 170 365 220 670 410 740 510 960 650 may be required. 500 230 140 260 170 365 220 1 670 1 410 740 510 970 650 CIRCULATOR-GPM 8 9 13 1 20 22 28 For special applications such as Multiple Boiler Systems,large domestic water loads,etc.,refer to the ASHRAE FSxture Count Method or contact a Weil-McLain representative.