Loading...
HomeMy WebLinkAbout32502-Z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-32866 Date: 02/05/08 THIS CERTIFIES that the building ADDITION Location of Property: 365 FREEMAN AVE MATTITUCK (HOUSE NO.) (STREET) (HAMLET) County Tax Map No. 473889 Section 139 Block 3 Lot 38 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated NOVEMBER 8, 2006 pursuant to which Building Permit No. 32502-Z dated NOVEMBER 17, 2006 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is DECK ADDITION TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR & AS PER CONDITIONS OF ZBA #5952 DATED 10/5/06. The certificate is issued to THOMAS & HELEN FOX (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A ELECTRICAL CERTIFICATE NO. N/A PLUMBERS CERTIFICATION DATED N/A r Authorized Signature Rev. 1/81 Form No.6 9 S 2 a TOWN OF SOUTHOLD f! t BUILDING DEPARTMENT 1�11 FEB 5 TOWN HALL -.. ------__- 765-1802 A�'PIJICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing"land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$25.00, Additions to dwelling$25.00, Alterations to dwelling$25.00, Swimming pool $25.00, Accessory building$25.00,Additions to accessory building$25.00,Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy -Residential $15,00, Commercial$15.00 Date. o D New Construction: Old or Pre-existing Building: (check one) / Location of Property: 3 �� L !ate Jam' House No. ( /�Street Hamlet Owner or Owners of Property: j h-�,��.� t�IQLI'l Suffolk County Tax Map No 1000, Section Y 23,?8 j /39'-3-39 Block jD p p 3 Lot 037 Subdivision Filed Map. Lot: Permit No. 3 c2 5'0 1. Date of Permit. p p/ Applicant: al� ZVA,,L_ Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: Applicant Signature � 3? 33 Cc 4—Z3,25 6 6 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 32502 Z Date NOVEMBER 17, 2006 Permission is hereby granted to: THOMAS FOX 365 FREEMAN AVE - P•0 If I O LI 7 MATTITUCK,NY 11952 for DECK ADDITION TO AN EXISTING SINGLE FAMILY DWELLING PER ZBA DECISION #5952 AS APPLIED FOR at premises located at 365 FREEMAN AVE MATTITUCK County Tax Map No. 473889 Section 139 Block 0003 Lot No. 038 pursuant to application dated NOVEMBER 8, 2006 and approved by the Building Inspector to expire on MAY 17, 2008 . Fee $ 150 . 00 Authorized Signature ORIGINAL Rev. 5/8/02 ' PtAALS BOARD MEMBERS Mailing Address: Ruth D. Oliva, Chairwoman �OF $o(/T�, � pl0 Southold Town Hall 53095 Main Road•P.O. Box 1179 Gerard P. Goehringer � � Southold,NY 11971-0959 James Dinizio, Jr. N Office Location: Michael A. Simon ^��� Town Annex/First Floor,North Fork Bank Leslie Kanes Weisman l'Ycou 54375 Main Road(at Youngs Avenue) Southold,NY 11971 http://southoldtown.northfork.net ZONING BOARD OF APPEALS 1 TOWN OF SOUTHOLD Tel. (631)765-1809•Fax(631)765-9064 FINDINGS, DELIBERATIONS AND DETERMINATION MEETING OF OCTOBER 5, 2006 ZB File No. 5952—Thomas Fox Property Location: 365 Freeman Road, Mattituck CTM 139-3-38 SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this application and determines that this review falls under the Type II category of the State's List of Actions, without further SEQRA steps as planned. PROPERTY FACTS/DESCRIPTION: The applicant's 18,348 square foot parcel is improved with a single- family, one-story house, as shown on the February 5, 1989 survey prepared by John Schnurr. The 'proposed garage' shown on this survey was withdrawn by applicant and is therefore not included in the applications filed with the Building Department or the Zoning Board of Appeals. BASIS OF APPLICATION: Request for a Variance under Section 100-244 (280-124), based on the Building Inspector's June 5, 2006 Notice of Disapproval concerning a proposed deck addition at less than 35 feet from the front lot line. The Notice of Disapproval notes a hand-drawn diagram with a proposed deck at approximately 28 feet. FINDINGS OF FACT The Zoning Board of Appeals held a public hearing on this application on September 28, 2006, at which time written and oral evidence were presented. Based upon all testimony, documentation, personal inspection of the property, and other evidence, the Zoning Board finds the following facts to be true and relevant: AREA VARIANCE RELIEF REQUESTED: The applicant wishes to construct a 12' x 21' (238 square foot) open, unroofed deck addition to replace an existing front entrance, as shown on the 9-22-2006 site map and 4-24-2006 construction diagrams prepared by Penny Lumber. REASONS FOR BOARD ACTION: On the basis of testimony presented, materials submitted and personal inspections, the Board makes the following findings: 1. Grant of the variance will not produce an undesirable change in the character of the neighborhood or a detriment to nearby properties because the deck is modest in both scope and size. The deck includes the step area within the 238 sq. ft. section of the 12 ft. deck as an entrance and as a place to relax and enjoy the neighborhood. 2. The benefit sought by the applicant cannot be achieved by some method, feasible for the applicant to pursue, other than an area variance. There is no other procedure available to place a modest, open deck at C Pago 2—October 5,2006 ZB File No. 5952—Thomas Fox CTM No. 139-3-38 the front of this house when the size of the deck is restricted to an allowable 4.9 ft. section under the minimum code requirement of 35 feet. 3. The variance granted herein is substantial and represents a 20% reduction from the code required 35 ft. minimum front yard setback. 4. The difficulty has been self-created. 5. No evidence has been submitted to suggest that a variance in this residential community will have an adverse impact on the physical or environmental conditions in the neighborhood. 6. Grant of the requested relief is the minimum action necessary and adequate to enable the applicant to enjoy the benefit of a new front deck with entrance, while preserving and protecting the character of the neighborhood and the health, safety and welfare of the community. RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing test under New York Town Law 267-13, motion was offered by Member Dinizio, seconded by Chairwoman Oliva, and duly carried, to GRANT the variance as applied for and shown on the site plan revised 9/22/06, and 4-24-2006 construction diagrams, prepared by Penny Lumber subject to the Condition that the deck construction shall remain open to the sky. Any deviation from the variance given such as extensions, or demolitions which are not shown on the applicant's diagrams or survey site maps, are not authorized under this application when involving nonconformities under the zoning code. This action does not authorize or condone any current or future use, setback or other feature of the subject property that may violate the Zoning Code, other than such uses,setbacks and other features as are expressly addressed in this action. The Board reserves the right to substitute a similar design that is de minimis in nature for an alteration that does not increase the degree of nonconformity. Vote of the Board: Ayes: Members Oliva (Chairwoman), Goehringer, Dinizio, Simon. (Absent was Member Weisman.) This Resolution was duly ad d (4-0). Ruth D. Oliva 10/30/06 Approved for Filing ��TO� : ' OF SOUTHOLD P-''OPERTY ''RECORD CAkRD � OWNER STREET ,. VILLAGE DIST. SUB. LOT FORMER OWNER N E S W TYPE OF BUILDING RES. l� SEAS. VL. FARM COMM. CB. MISC. Mkt/ Value LAND IMP. TOTAL DATE REMARKS 6 .13 s0 d •S70 C1 iz 0 n o o G o � a 73 ' 2 1-7 AGES 0 0 Lo .�3 0 I LDING C DITI N � , t.e.+� �`' �'i"' - /'fir 'Ll � f o Co �p p NEW NORMAL BELOW AB FARM Acre Value Per Value Acre /86f) DP-c.V— +A-OIDi ca�.�l 9oc), Tillable 1 Tillable 2 Tillable 3 Woodland Swampland FRONTAGE ON WATER Brushland FRONTAGE ON ROAD D House Plot DEPTH BULKHEAD Total DOCK I s 1 r COLOR _ N TRIM MEN 1101 r,•'id.. is i i M. Bldg. ,k, �� �, 5� 3A 7 Foundation �r Bath / Dinette Extension Basement ):::'o E Floors � �� K. Extension Ext. Walls /4 S/3 Interior Finish �L � LR. Extension Fire Place U Heat FS DR. Type Roof Rooms 1 st Floor BR. PorchhA,,, Z,.-X .3 Recreation Room Rooms 2nd Floor FIN. B. Porch Dormer Breezeway Driveway Garage Patio Total 3 3 7 SOUTyolo LSD o2— 7— * • �# courm,��' TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [gFINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION 4 REMARKS: L14 / v DATE ( 3a _ v � INSPECTOR SOUTy�Io 3 �� _ 'F coutom,� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION �IUMING / STRA PI [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: CZAR DATE INSPECTOR 50 �pF SOUTy cAt ��'y000Ni'I,Nc� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ OUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: DATE INSPECTOR s FIELD INSPECTION REPORT I DATE COMMENTS ` 00 FOUNDATION(1ST) O y ------------------------------------- FOUNDATION(2ND) A11A t`�ri IL li z 0 ROUGH FRAMING& U� y PLUMBING I. i i INSULATION PER N.Y. -- — y STATE ENERGY CODE FINAL ADDITIONAL COMMENTS �1 O Z rn . (n J � 0 o� z x d b y TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey www. northfork.net/Southold/ PERMIT NO. �a �-� Check Septic Form N.Y.S.D.E.C. Trustees ' Examined U ,20_Vk Contact: Approved ,20 Mail to: Disapproved a/c ��,/t(/ I Phone: Expiration 20 �r (� Building Inspector APPLICATION FOR BUILDING PERMIT Date , 20 ,. �.'.'''iJL✓ t INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing, the extension of the permit for an addition six months.Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name,if a corporation) (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises 'naw s /' lox Sr. t lk le m tfi-aX (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on hich proposed work will be done: House Number Street a9let County Tax Map No. 1000 Section <.`' ' f 3 3 Block,,, „C�: �. .,. Lot Subdivision Filed Map No °'~",r' -' `' Lot (Name) 2. State existing use and occupancy of premises and int ded use and occupancy of proposed construction: a. Existing use and occupancy ' b. Intended use and occupancy . 3. Nature of work(check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work Deck (Description) 4. Estimated Cost Sk"V, Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front 'V 2 z Rear y2 ' Depth y Height Number of Stories y Dimensions of same structure with alterations or additions: Front y z. 2— Rear "1z• 2 Depth 3 �. Height -- Number of Stories 0 `8. Dimensions of entire new construction: Front LA / Rear Depth /;z Height f._ Number of Stories 9. Size of lot: Front /00 Rear /0 a. ?2- Depth We.sZ- /Y4.37 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO )(_Will excess fill be removed from premises? YES NO X 14. Names of Owner of premise IlViZAddress;fir it et"w rA, Phone No. Zff"J'2245,2— Name of Architect Address r ,tck Phone No Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES x NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) SS: `OUNTY OF nn ) � m,05 being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above'named, (S)He is the (Contractor,Agent, Corporate Officer;etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn o efore me this p day of 20 i�'& Notary Public Signature of Applicant RIC� JERT NQtary3 isc StaWO News York 36-4741154, Qualified irt'Nassau/Suff Co ti Commission Expires d / �O of GOJN� N � E COE; 0 N N �o N 0 z i O �L N101F JAMES McMAHON& AUDREY McMAHON N ' o O EX�s��NG O GKQ� N 31S IE 42 2 6 5, 26•a ,eX,So"i"ok3SE 3,2 A.0 17 SQ� w PR- 0- N 1 W OEGK � to 0 w� 1 N N N o 0 SITE DRAWING IS BASED ON INFO O co FROM SURVEY DATED 05-05-1999 + LAND SURVEYORS AS PROVIDED BY THOMAS&HELLEN FOX OF W 100 p0 0 IN NO CIRCUMSTANCE SHALL PEN RESPONSIBLE FOR ANY MISINFOF INCONSISTENCIES ON SURVEY 051,40„ VV * THIS DRAWING TO BE USED AS G S 71 VANS ONLY AND SHALL NOT BE CONSI[ F SITE PLAN .OPOSED CONSTRUCTION 1"=20' M I, SEP 2 5 2006 i a C3:�a6+_I¢; '!.OAFOti /� REVISED ON 9- 22- 2006 q q nbzt, p ury e y-orq, ,,­.,- --ou t, ung, -__j ng, ­7 d' S 'New 6�* ,0 J., T �,­_7, -27I�723,03 �z C u?"19; y ldhd Sum --A X ''W ' t "Yrof.6.9sional T p tz �s h.......... OTES N: �::Ab MA SUB \A PbL 4 '0 o.. -WE-tHEREBY,,:'CERMF..... X 71 HIS;-5 .'Oi�,i�E�Y.',,,,WAS�,�PREPARED�'�IN W, bt 'R 0 F ;'-S C� u w URR w -5 PART-, GA 1 'Y�S 6 ff,61 k Y&k�%,:, 'oun,, u ..... nTLE" S 9 P A Eb R 9 E '40 �SCAL UMENT,SET,. STAKE,FOUND w_" 61UMENt�FOUND STAKE SET A' W m D FORM NO. 3 NOTICE OF DISAPPROVAL DATE: June 5, 2006 TO: Thomas Fox 365 Freeman Road Mattituck,NY 11952 Please take notice that your application dated May 25, 2006 For a permit for a deck addition to a single family dwelling at Location of property: 365 Freeman Road, Mattituck County Tax Map No. 1000 - Section 139 Block 3 Lot 38 Is returned herewith and disapproved on the following grounds: The proposed structure on this 18,348 sq. ft. lot, is not permitted pursuant to Article XXIV, 100-244 which states: "This section is intended to provide minimum standards for granting of a building permit for the principal buildings of lots which are recognized by the town under 100-24, are non-conforming and have not merged pursuant to 100-25. The allowable minimum front yard setback is 35'. The proposed front yard setback is approximatel2 8'(feet. Az-���- - cl'-� Authorized Signature Note to Applicant: Any change or deviation to the above referenced application may require further review by the Southold Town Building Department. v 0 z n i t= z �f• O ox z_ 3 � w Q! U Q >- A f� A Pq O Lo lL p z Q' c- J W Q Z J p Z W 2 it Ili ~ O _ M �Pq O M Lo O 0 a ti z ti ' W d �r nn I W 0) co Z "T O o iL z ti �Ll I M co ..1 •° if I 1 11 1 11 P �• a � a I.• I L• I ,. COMPLY WITH ALL CODES OF == �== �•^'-� =f=� NEW YORK STATE & TO1AVN CODES AS REQUIRED AND CONDITIONS OF 4-4 PROPOSED DECK CERTIV !, ._S0UTH0LDTO� VN Z3A � , ; NAILING (,�"'' ., . C: ; ;, , S0UTH0LDT&1'dN PL, llfi'NG BOARD z REQUIRED. SOUTNOLDTO''*Nt i'RJSTEES N.Y.S.DECi 1 1, O wo Z OCCUPANCY OR `� e� `�� ' o ALL CONSTRUCTI p���Frsst® ��',r USE',IS UNLAWFUL �4 MEET THE REOUIREMEEN S OF THE 3 0 WITHOUT CERTIFICATE CODES OF NEtiV Yc�RK STATE. �, z z OF OCCUPANCY W Q SOUTHOLD BUILDING DEPARTMENT CRITERIA O APPROVED AS NOTED 1 OCCUPANCY CLASSIFICATION R-3 RESIDENTIAL-SECTION 310 BUILDING CODE N.Y.S. _ USE DWELLING UNIT-SECTION 310-310.2 DATE: B•p•# 3,13Z)L : 2 HEIGHT TOTAL 2'-6" FEE: /6� - BY: }-+ 3 TYPE OF CONSTRUCTION WOOD FRAME CONSTRUCTION FT P10TIFY BUILDING DEPAr-iTVENT AT 41 DESIGN CRITERIA PRESCRIPTIVE DESIGN- 1995 HIGH WIND EDITION WFCM 765-1°02 8 AM TO 4 P FOR THE FOLLOWING INIE Er'710;!g; 5 FRAMING ELEMENTS SEE FLOOR PLANS AND SECTIONS 1. FOUPJDATION - Tw0 RECUIRED 6 DESIGN LOAD CALCULATIONS SEE SHEET FOR POURED r-C) �CRETC_ 7 WINDOW AND DOOR SCHEDULE N/A IV 2• - FRAMIi�G & PLUM SING 8 LOAD PATH SEE SHEET 2 W 3. INSUU,TION 9 NAILING SCHEDULE SEE SHEET 3 0 4. FI,}AL - CONSTRUCTION MUST 10 EGRESS N/A r- N 11 PLUMBING RISER DIAGRAM N/A BE COA4?LETS �OR C.O. o ALL CONS T RIJC,_i0fiv SHALL MEET THE 12 FIRE PROTECTION N/A z REQUIREMENTS 07 THE CODES OF NEW 13 TRUSS DESIGN DRAWINGS N/A w z YORK STATE. NOT RESPONSIBLE FOR 14 ENERGY CALCULATIONS N/A = J DESIGN OR CONSTRUCTION ERRORS. 1 o- z DEGiG CONST. ° 5/4"X6" DECKING SCREWED OR NAILED ON w v 2"X5" ACQ F.J. a 16" O.G. ON (2)2"XIO" ACQ a GIRDER ON 5" PG P I ER5 W/S I GI=00T 20" FOOTI N65 _ o W/APPROVED HURRICANE STRAPS TO GIRDER i z (SEE SPECIFICATIONS SHEET) _1 N o AGQ o 0 z EXISTING ~ W a , 11E i i(2)2"XIO" P�.Q GIRDER i i i i w U ¢ >- HOUSE . .. GRADE ;; x0 � klA� LL � m w z ` —J Y W 0 CK L 1 4"X4" A00 POST WN5P O M Q SECTION A—A CONNECTOR PAU44 TO 5 PG � g PIER ON B 1 G FOOT 24 (TYP) 6•=y E_= SCALE: 5/8,, = 1'—O" NOTE: °° ti Lo PROVIDE U5P JU525 OR EQUAL CONNECTOR a o FROPOSEro) SOUTH ELEVATION TO ALL FJ (5EE 5PE05. SHEET) W v- � 50ALE: Y4" = I'-O" PROVIDE USP RT l OR EQUAL CONNECTOR � r TO ALL FJ (5EE SPECS. SHEET) c� co PROVIDE U5P CONNECTOR PAU44 TO Q z o 5" PG PIERS (5EE SPECS. SHEET) 0 o z r M co 2" X 5" ACQ LEDGER BOLTED EX I ST I N6 TO EXISTING STRUCTURE W/IVY 0 LAG BOLTS 52" OG HOUSE (5EE 5PE05 SHEET) co w y p w z IL u_ p w III , z o EXISTIN � N III PROPOSED u- A o HOUSE G it /. i _ DECK at z IIXIO 11 �0322 (2 2 <� � GIB , N �4" MAX. 2'-O' 3'-2" 6'-�" 6'-�i" 2'_o , I I I 1 DECK LINE 21 1-off .� U- O Lo PROPOSED FOUNDATION/FRAMIN& PLAN PROPOSED NEST ELEVATION " 0 z 50ALE: Y4" = I'-O" SCALE: Y4" = 1'-0" w z GENERAL CONSTRUCTION NOTES GENERAL FRAMING NOTES NAILING SCHEDULE 1.The information on this set of construction documents is to relate basic design 1.All walls,2x4 and 2x6,to be stud grade or better 16"o/c. All other framing material TABLE 3.1, INCLUDING 3.3 A No 3.9 intent and framing details. They are intended as a construction aid,not a substitute to be#2 douglas fir or better. '1995 s B c HIGH WIND EDITION WOOD FRAME CONSTRUCTION M A N U A L for generally accepted good building practice and compliance with current New York JOINT DESCRIPTION NAIL QUALITY NAIL SPACING state building codes. The general contractor is responsible for providing standard 2.All wood framing in contact with concrete or masonry to be pressure treated. construction details and procedures to ensure a professionally finished,structural) IROOF FRAMING v p P Y Y (RAFTER TO TOP PLATE TOE NAILED 8'-0" WALL: 3-8d PER RAFTER _ sound, and weatherproof completed product. 3. Provide double floor joists under all walls parallel to floor joist span direction unless 10'-0" W ALL: 4-8d PER RAFTER Z y • otherwise specified. CEILING JOISTTO TOP PLATE TOE NAILED 8'-0" WALL: 3-8d PER JOIST lxy 2. General Contractor to coordinate all sub contractors,scheduling of work,and 1 0' WALL: 4-8d PER JOIST CEILING JOIST TO PARALLEL RAFTER FACE NAILED SE E E E TABLE 3.7 EACH LAP V interaction between trades. 4. Provide x-bracing or solid blocking at a maximum of 8'-0"o/c for all dimensional iC E IL IN G JOIST LAPS OVER PARTITIONS FACE NAILED S E E TABLE 3.7 EACH L A P lumber floor joists. COLLAR TIE TO RAFTER FACE NAILED SEE TABLE 3.4 PER TIE LL 3.The general contractor is responsible for ensuring that all work and construction IB O B K IN G T O R AFTER TOE NAILED 2-8d EACH END V Ill Z (RIM BOARD TO RAFTER END NAILED 2-16d EACH END Z N = meets or exceeds current federal,state,and local codes,ordinances and regulations, 5. Floor construction:3/4"tongue and groove plywood subfloor. Finished material to be z0 O etc. These codes are to be considered as part of the specifications for this building applied over subfloor. Glue and screw plywood decking to floor joists. 'WALL FRAMING and should be adhered to even if they are invariance with the plan. 'TOP PLATE TO TOP PLATE FACE NAILED 2-1 6d PER F O O T TOP PLATES AT INTERSECTIONS FACE NAILED 4-16d JOINTS - EACH SIDE 6.All window and door headers to be minimum(2)2x10 unless otherwise specified. STUD TO STUD FACE NAILED 2-1 6 d 24" O/C Z 4. Dimensions shall take precedent over scale drawings(do not scale drawings). All interior headers to be(2)2x10 unless otherwise specified. HEADER To HEADER FACE NAILED 16 d 16" O/C ALONG EDGES Ld 'TOP OR BOTTOM PLATE TO STUD END NAILED 2-16d PER 2X4 STUD 3 J W 5.The designer has not been engaged for construction supervision and assumes no 7. Provide full solid blocking under all bearing walls. 3-16 d PER 2 xs STUD 4-16d PER 2X8 STUD W C.) Q } responsibility for construction coordinating with these plans,nor responsibility for BOTTOM PLATE TO FLOOR JOIST, A 0 A t>a construction means, methods,techniques,sequences,or procedures,or for safety 8.All beams to have adequate bearing at each end or as specified. B A N D J O IS T, END JOIST, OR BLOCKING I FACE NAILED 2-16 d - PER FOOT precautions and programs in connection with the work. There are no warranties for a FLOOR FRAMING specific use expressed or implied in the use of these plans. 9.All flush beam and joist intersections to have galvanized hangers. JOIST TO SILL, TOP PLATE, OR GIRDER 'TOE NAILED 4-8d PER JOIST X � BRIDGING TO JOIST ;TOE NAILED 2-8d EACH END O 6. Refer to floor plans,exterior elevations,and window schedule for types and sizes of 10.A typical structure that is designed as a"Partially Enclosed Building"shall have BLOCKING TO JOIST TOE NAILED 2-8d EACH END V- 0 BLOCKING TO SILL OR TOP PLATE TOE NAILED 3-16d EACH BLOCK Z r windows. All windows to be Andersen high performance quality or approved equal. exterior walls and roof to be sheathed with %"exterior grade plywood or LEDGER STRIP TO BEAM FACE NAILED 3-1 6 d EACH JOIST W 0 ZZ Z "OSB plywood,group 1,APA rated. Plywood to span over all plates and headers. JOIST ON LEDGER TO BEAM I T O E NAILED 3-8d PER JOIST J 7.Door and window headers to align unless otherwise noted. BAND JOIST TO JOIST ;END NAILED 3-1 6d PER JOIST 11. Provide insulation baffles at eave vents between rafters. BAND JOIST TO SILL O R TOP PLATE TOE NAILED 2-1 6 d PER FOOT W W Y 8.General contractor is to ensure that masonry and prefabricated fireplace 06 W U ROOF SHEATHING Oi!f � � construction meets or exceeds all manufacturer's specifications and applicable codes. 12. Exterior flashing to be correctly installed at all connections between roofs,walls, STRUCTURAL PANELS ; 4' P E R IM E T E R EDGE ZONE - 16" O/C - 6" AT PANEL U.. chimneys, projections,and penetrations as required by approved construction EDGES AND AT INTERMEDIATE SUPPORTS IN THE ELO 9. General contractor to consult and coordinate with the owner and the plans for all practices. s d PANEL FIELD 0 co Q INTERIOR ZONE - 16" O/C - 6" AT PANEL EDGES AND 12" built in items such as bookcases,shelving,pantry,closets,etc. Sd IAT INTERMEDIATE SUPPORTS IN THE PANEL FIELD PQ 13.General contractor to provide adequate attic ventilation and roof vents. FOR ROOF SHEATHING W ITHIN 4'-0" OF THE PERIMETER EDGE OF THE ROOF, INCLUDING 4'-0- ON EACH SIDE OF THE ROOF PEAK, THE 4'-0- O PERIMETER EDGE ZONE ATTACHMENT REQUIREMENTS SHALL BE USED. � 10. Provide hardwired smoke detectors,with battery backup,on all floors and in each bedroom,verify with local code requirements as per Section R317, New York State 14. Provide appropriate soffit ventilation at overhangs. CEILING SHEATHING Residential Construction Code. Install carbon monoxide detectors as per code. GENERAL PLUMBING NOTES GYPSUM WALLBOARD 5 d COOLERS 7" EDGE / 10" FIELD WALL SHEATHING GENERAL FOUNDATION NOTES 1. Plumbing subcontractor to be responsible for adhering to all applicable code and STRUCTURAL PANELS 8d 4' EDGE ZONE - 16" O/C - 6" AT PANEL EDGES AND 12" 00 ti AT INTERMEDIATE SUPPORTS IN THE PANEL FIELD F'- Lf) safety requirements. 8d INTERIOR ZONE - 16- O/C - 6" AT PANEL EDGES AND 12" O 1. General contractor to review plans, elevations,and details to determine intended AT INTERMEDIATE SUPPORTS IN THE PANEL FIELD O hei hts of finished floors above typical grade. 2. If wall plates or joists are cut during the installation of plumbing fixtures or FIBERBOARD PANELS 7!1 6" 6d 3" EDGE / 6" FIELD Z ti 9 ( ) tYP 9 P 1 g P g '25/32" 8d 3" EDGE / 6" FIELD Z ~ IRT equipment provide bracing to be framing back together. GYPSUM WALLBOARD 5 d COOLERS 7" EDGE / 10* FIELD W Bd 4' EDGE ZONE - 16" O/C - 6" AT PANEL EDGES AND 12" W 2.All footings to rest on undisturbed soil. GENERAL HVAC SYSTEM NOTES HARDBOARD j AT INTERMEDIATE SUPPORTS IN THE PANEL FIELD (MD 3. Provide'/"expansion joint material between all concrete slabs and abutting concrete or masonry walls occurring in exterior or unheated interior areas. 1. Mechanical subcontractor is responsible for adhering to all applicable codes and o safety requirements. TABLE 37 O Z o 4. Concrete on 4 . sand or gravel fill minimum,with 6x6-10/10 wire mesh reinforcing. 1995 SBC HIGH WIND EDITION WOOD FRAME 0 Interior slabs to be placed on 6 mil.stabilized polyethylene vapor barrier. 2. HVAC subcontractor to fully coordinate all system data and requirements with the equipment supplier. CONSTRUCTION MANUAL Z r 5. Provide crawl space ventilation per local code requirements. RAFTER SPACING 16" O/C CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA 3. HVAC subcontractor to provide final system layout drawing and submit it to general WEATHERING S E V E R E co CID 6. General contractor to install cop-r-tex(or copper)sheet metal termite shields contractor, owner,and equipment supplier for final review and approval. ROOF PITCH ROOF SPAN 28 36 FROST LINE DEPTH T-0" between all wood surfaces that are exposed to concrete or masonry surfaces. TERMITE MODERATE TO HEAVY 3:12 5 8 11 14 DECAY SLIGHT TO MODERATE 7. Dampproof exterior of foundation with a bituminous coating as per code and soil 4:12 4 6 8 11 WINTER DESIGN TEMP. 11 conditions. 5:12 3 5 7 9 ICE SHIELD UNDER- AS PER MANUFACTURER'S GENERAL WIND PROTECTION CONNECTION NOTES LAYMENT REQUIRED SPECIFICATIONS / STATE CODE GENERAL FLOOR PLAN NOTES Adapted from Standard for Hurricane Resistant Residential Construction; SSTD 10-99 7:12 3 4 5 6 -M and 1995 SBC High Wind Edition Wood Frame Construction 9:12 3 3 ___4L 5 FLOOD HAZARDS 1. Dimensions shall take precedent over scale drawings(do not scale drawings). Fasteners and Connectors for Wood Frame Construction 12:121 3 31 31 4 . 2.All interior walls to be covered with'/"gypsum board With metal comer reinforcing. 1.A continuous load path between footings,foundations walls,floors,studs and roof Tape,float,and sand(3 coats). framingshall be provided. �4 T In P .TABLE 3 .4 �r � � •� 3.Walls common to garage and house to have a layer of 5/8",fire rated gypsum board 2.Approved connectors,anchors and other fastening devices not included in the 1995 s B C HIGH WIND EDITION WOOD a r� W at garage side With T-0"return on adjacent walls and ceiling. Manufactured lumber ''FRAME CONSTRUCTION MANUAL �� ''� ' �`� ~ r_0 Standard Building Code,Table 2306.1 shall be installed in accordance with ty !� Z requires 2 layers of 5/8",fire rated gypsum board. RAFTER SPACING 16" O/C DESIGN LOAD CALCULATIONS ` 'a `� '`� W manufacturer's recommendations. I �E,,iC} �:120 mph FASTEST W INDSPEED J 4.All bath and toilet area walls and ceilings adjacent to wet areas to have water 0 g I 3. Metal plates,connectors, screws, bolts,and nails exposed directly to the weather or ROOF ROOF NUMBER MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS (Ibsf) }/ resistant gypsum board,or wall tile set on wonderboard or equal. subject to salt corrosion in coastal areas, shall be stainless steel or hot dipped Z P IT C H SPAN (ft) OF NAILS EXTERIOR BALCONIES 60 W_ galvanized. 4:12 12 3 DECKS 40 O 4.Where windows and doors interrupt wood structural panel sheathing and siding, 16 4 ATTICS WITHOUT STORAGE 30 0 2 0 5 J framing anchors or connectors shall be provided at the top and bottom of cripple 24 6 ATTICS WITH STORAGE 40 LL studs, header studs,and at least one stud at each side of opening. 28 7 ROOMS (OTHER THAN SLEEPING ROOMS) 40 Z 32 8 ISLEEPING ROOMS 30 Q 5. Ridge straps shall be attached to each pair of opposing rafters except where collar 36 - I W ties of 1 x6 or 2x4 lumber is located in upper third of attic space and attach to each pair 5:12 12 3 CRITERIA FOR CALCULATION OF DEAD LOAD O of rafters. 16 a 20 4 ACTUAL WEIGHTS OF MATERIALS REFERENCED TO A.I.A. _ 6.When a structure is designed as a"Partially Enclosed Building" uplift connectors 24 5 8 s ARCHITECTURAL GRAPHIC STANDARDS shall now require 20 gage strapping with six 8d nails provided at each rafter bearing. 32 7 36 7 SNOW 7. Floor to floor hold-downs to be provided every 48,and every 16"within 4'of exterior 6:12 12 3 IGROUND SNOW LOAD 145 lbs. comers. 16 3 20 4 SEISMIC 8. Sill Plate to Foundation Anchorage: Sill plate shall be anchored to the foundation 24 5 with anchor bolts having a min. bolt diameter of 5/8"and 3"x 3"x 1/8"washers. A 28 5 DESIGN CATEGORY B minimum of one anchor bolt shall be provided within 6 to 12 inches of each end of 32 s each plate. Anchor bolts shall have a minimum embedment of 7 inches in concrete/ 7:12-12:12 1 2 2 WIND masonry foundations. Anchor bolts shall be located within 12 inches of comers and at 16 3 WIND SPEED 120 mph 0 spacing not exceeding 4 feet on center. 20 4 EXPOSURE CATEGORY 1B LO 24 4 In N THESE NOTES ARE GENERAL CONSTRUCITON NOTES. THEY ARE NOT 28 5 SPECIFICALLY WRITTEN FOR THIS PLAN. THEY ARE TO BE CONSIDERED AS 32 6 Z GENERAL GUIDELINES ONLY AND SHOULD BE DISCUSSED WITH YOUR 36 61 W Z GENERAL CONTRACTOR BEFORE CONSTRUCTION BEGINS. = J to d WIND LOAD PATH CONNECTION AND CONSTRUCTION DETAIL DRAWINGS USE THE FOLLOWING OR APPROVED USP METAL CONNECTORS FOR PROPER WIND RESISTANT CONSTRUCTION. FOLLOW MANUFACTURES RECOMMENDED INSTALLATION INSTRUCTIONS TO ACHIEVE MAXIMUM UPLIFT LOAD CAPACITY. I 4'MAX. I 4'MAX. 'V I ( 4"DIA.MAXIMUM 4 DIA.MAXIMUM POST GIRDERIHEADER z � V � Z POST/COLUMN T N ZO12'xl2'xl2'CONCRETE FOOTINGO Z LLJ 3 LrJ DECK POST FTG. CONNECTION W U ¢ >- DECK/PORCH RAILING LOCATION USP NUMBER DESCRIPTION APPLICATION A (61 1 AI Pq POST-TO-GIRDER/HEADER CONNECTION 4X4 POST PAU44 OR WE44 POST/BEAM ANCHOR APPLY TO STAIR RAILINGS EACH FOOTING 6X6 POST PAU66 OR WE66 POST/BEAM ANCHOR APPLY TO EACH FOOTING USE MIN.(2)1/2'DIA.GALV.BOLTS WITH WASHERS AND NUTS X to 0 CA MINIMUM LL- Z Y HANDRAILS GIRDE W Y POST = z W U CsIRDER/HEADER °� p LL L0 F- BALUSTERS RIMIDECK JOIST o CONCRETE PIE ••',." M Q POST/COLUMN ,• o OPEN BALUSTER ATTACHED TO WALL •`•" HANDRAIL CONNECTION ALL HANDRAILS SHALL BE CONTINUOUS THE FULL LENGTH POST-TO-DECK CONNECTION OF THE STAIRS. HANDGRIP PORTION OF ALL HANDRAILS HEADER/GIRDER-TO-POST CONNECTION � SHALL NOT BE LESS THAN 1-1/4"NOR MORE THAN 2'IN LOCATION USP NUMBER DESCRIPTION APPLICATION ti CROSS SECTIONAL DIMENSION,OR THE SHAPE SHALL USE MIN.(2)1/2'DIA GALV.BOLTS WITH WASHERS AND NUTS (2)BEAMS PAU44 OR WE44 POST I BEAM ANCHOR APPLY TO EACH PIER C:) PROVIDE AN EQUIVALENT GRIPPING SURFACE GIRDER/HEADER TO POST/COLUMN CONNECTION (3)—BEAMS PAU66 OR WE66 I POST I BEAM ANCHOR APPLY TO EACH PIER 0 W ti Z ~ FLASHING TUCKED UNDER W V- TOP PIECE OF SIDING AND W M LAPPED OVER FIRST CONTIN. r— CO GIRDERIHEADER PIECE OF SIDING BELOW UNDISTURBED SOIL 0 1l2"DIA.LAG BOLTS W/WASHERS LAY PLASTIC BASE DIRECTLY ON ljo >- p UNDISTURBED SOIL(ORGANICS REMOVED) Q Z O CONNECTED TO BLDG.(a�16'OC LEVEL BASE p O STAIR TREAD °o FIT CONSTRUCTION TUBE AND PLUMB r POST/COLUMN BRACE TUBE Z ti °° FILL AS PER MANUFACTURES INSTRUCTIONS RIM BOARD FLOOR FRAMING 2x Jo1sT5 u1=111�m1= _ = III=III= _ _ M STRINGER III-III;III-III;III=III;III-III-III-11 � a;LOCKING FOR JOIST HANGER POST-TO-GIRDEWHEADER CONNECTION LAG BOLTS e , LOCATION USP NUMBER DESCRIPTION APPLICATION IRIM JOIST/BD. n 4x4 SOLID COLUMN PBS44/PBSE44/KC44 IPOST CAP ANCHOR APPLY TO EACH COLUMN �• DISTURBED / POOR SOIL STRINGER TO DECK/PORCH CONNECTION 6x6 SOLID COLUMN PBS66/PBSE66/KC66 POST CAP ANCHOR APPLY TO EACH COLUMN LAY 4e LAYER OF CRUSHED STONE OR HOLLOW COLUMN SIMPSON STRR1/2 H.C. ANCHOR APPLY TO EACH COLUMN DECK/PORCH LEDGER CONNECTION GRAVEL LEVEL AND COMPACT BY HAND LAY PLASTIC BASE ON COMPACTED GRAVEL LEVEL BASE FIT CONSTRUCTION TUBE AND PLUMBBRACE TUBE I' FILL AS PER MANUFACTURES INSTRUCTIONS I= III III III-III III-III I►I-III III-11 H WOOD JOIST Z W WOOD JOIST JOIST BLOCKING CONC. PIER FOOTING 0 BIGFOOT SYSTEMS FOOTNG FORM Z_ GIRDERIHEADERIN ACCORDANCE WITH SECTION 104.11 OF N.Y.S.RESIDENTIAL CODE THIS DESIGN or_ WOOD JOIST WOOD GIRDER COMPLIES WITH THE INTENT OF THE CODE AND THE MATERIAL OFFERED IS 0 GIRDER/HEADER AT LEAST THE EQUIVALENT IN DURABILITY AND EFFECTIVENESS OF THAT 0 O PRESCRIBED THE CODE. J THE DIVISION OF CODE ENFORCEMENT AND ADMINISTRATIONS FINDS THIS PRODUCT ILL FLUSH JOISTS WITH HEADER/GIRDER ACCEPTABLE FOR USE IN N.Y.S.BASED UPON ICBO EVALUATION SERVICE REPORT Q SPLICED JOISTS OVER HEADER/GIRDER ER-5495 AND SUBJECT TO THE CONDITIONS THEREIN. .� Z ALL JOISTS CONNECTED TO A FLUSH HEADER TO BE SUPPORTED WITH �. - � , ;� THE PROPER STEEL CONNECTOR SPLICED JOISTS OVER HEADER/GIRDER PROVIDE BLOCKING BETWEEN JOISTS THAT ARE SPICED AND ri Q IF ABLE,SET FIR JOISTS APROX.1/4"HIGHER THAN LVL HEADERS LOCATION USP NUMBER DESCRIPTION APPLICATION USE WITH RT10 TYDOWN ANCHORS ',� W TO ALLOW FOR SHRINKAGE. JOIST TO GIRDERIHEADER I RT10 ITYDOWN ANCHOR ICONNECT TO EACH JOIST Ic A 0 PL� DECK & PORCH NOTES: NAILING SCHEDULE - � �- 1).Unless otherwise noted,all framing material to be#1 ACQ pressure treated lumber. NAIL NAIL it`® 0322-•1 �� All fasteners,hangers and anchors to be galvinized or stainless steel. JOINT DESCRIPTION NOTES QTY. SPACING ��FESS1f3P 2).Girders for deck joists to be bolted or anchored to each post or pier with washers and nuts. JOIST TO: 4-8d COMMON PER TOE Girders on concrete piers shall be anchored with proper steel connectors anchored SILL,TOP PLATE OR GIRDER JOIST NAIL G into concrete with ammimumlrr dia xPlongancorboft with washers and nuts. CLIMATIC & GEOGRAPHIC, DESIGN CRITERIA BRIDGING EACH TOE 2-BdCOMMON 3).Posts supporting gibers shall be anchored to a 12'x12'x12"thick concrete footing. GROUND WIND SEISMIC FROST WINTER ICESHIELD TO JOIST END NAIL FLOOD BLOCKING EACH TOE SNOW SPEED DESIGN WEATHERING LINE TERMITE DECAY DESIGN UNDERLAYMENT Use a minimum 7'long dia x g anchor bolt with washers and nuts.Footings Shall HAZARDS be 4 fL below grade. LOAD (MPH) CATEGORY DEPTH TEMP. REQUIRED TO JOIST COMMON END NAIL MODERATE SLIGHT TO BLOCKING TO: 3-16d COMMON EACH TOE d 4).Deck joists to have blocking at TO o.c.. 45 LBS. 120 B SEVERE 3 FT. TO HEAVY MODERATE 11 NONE - SILL OR TOP PLATE BLOCK NAIL LL. LEDGER STRIP 3-16d COMMON EACH FACE 5).A minimum of 10 inch flashing shall be installed between the building and ledger. TO BEAM JOIST NAIL 0 Ledger to be fastened to building with 1/2'dia.bolts with washers and nuts JOIST ON LEDGER PER To at 16"o.c. TO BEAM 3-8d COMMON JOIST NAIL N 6).Concrete piers shall be a minimum 6'above grade. BAND JOIST 3-16d COMMON PER END O TO JOIST JOIST NAIL Z 7).All joists to be supported with hangers and anchors.Each Joist shall also be anchored BAND JOIST TO: 2-16d COMMON PER TOE NAIL to girder(s). SILL OR TOP PLATE FOOT W Q 2 J