HomeMy WebLinkAbout33060-Z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-32887 Date: 12/14/08 THIS CERTIFIES that the building SOLAR PANELS Location of Property: 205 CR 48 MATTITUCK (HOUSE NO.) (STREET) (HAMLET) County Tax Map No. 473889 Section 113 Block 12 Lot 10.4 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated MAY 15, 2007 pursuant to which Building Permit No. 33060-Z dated MAY 22, 2007 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is INSTALLATION OF SOLAR PANELS ON AN EXISTING COMMERCIAL BUILDING AS APPLIED FOR. The certificate is issued to THOMAS & ELLEN TALBOT (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A ELECTRICAL CERTIFICATE NO. 117453C 10/22/07 PLUMBERS CERTIFICATION DATED N/A Autho ized Signature Rev. 1/81 • Form No.6 ' TOWN OF SOUTHOLD ' BUILDING DEPARTMENT s s TOWN HALL + 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with_tlze following:_'-J j ._.. ! A. For new building or new use: l. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in.system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land use's: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied; the Building hispector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$25.00,Additions to dwelling$25.00, Alterations to dwelling$25.00, Swimming pool $25.00, Accessory building$25.00, Additions to accessory building $25.00, Businesses $50.00, 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00 1 Date. New Construction: Old or Pre-existing Building: V (check one) Location of Property: 2 03' House No. Street Hamlet Owner or Owners of Property: 40 Suffolk County Tax Map No 1000, Section // 3 Block l s Lot J� Subdivision Filed Map, Lot: Permit No. �& ® ZDateofPermit, VZlo7 Applicant: Health Dept. Approval: /V/IV Underwriters Approval: Planning Board Approval: X01 Request for: Temporary Certificate Final Certificate: V check one Fee Submitted: $ � - 739�� Applicant Signatu'e e..o FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 33060 Z Date MAY 22 , 2007 Permission is hereby granted to: THOMAS & ELLEN TALBOT 205 RT 48 MATTITUCK,NY 11952 for INSTALLATION OF SOLAR PANELS ON AN EXISTING COMMERCIAL BUILDING AS APPLIED FOR. at premises located at 205 CR 48 MATTITUCK County Tax Map No. 473889 Section 113 Block 0012 Lot No. 010 . 004 pursuant to application dated MAY 15, 2007 and approved by the Building Inspector to expire on NOVEMBER 22 , 2008 . Fee $ 250 . 00 1� '71 rized ignature ORIGINAL Rev. 5/8/02 ✓:< :•:r. 't:� r:•'3 ii:•.- �i•:� -i�e <?:w �?a %.,a ,�S_.-Ir••:;i�_vr,`i:»_r:;:;.;4: Tr`iS»_r�:;}�_�i;•_$'i:;i�,...r.�;4\ rf.•+ti .l.$K ;::;•. F�. :::•,.. fi::•• - -(r..::�..f.:t4. ,{'...� fvt.1.r:�•..�+•++�.•..~`•`r:...•..�>:i�0..•t: r...•4.1....3..y...�.y...•.may...•4 .+•• �•�.yp•'r�i 4•.:•:�ri.4•.:%o ri.4•.:•:�r/i i•:•'o Pi.4•.:•'d r`rh•.••:••0 0.h 4•.V iPl p••Po Iir.••:••o rYr 0.•.O Nr•..•.Nr 9 p•d N ..,•J r rr 4.,.o r rr 9..•d Or/0•;Orr •.f .•:•rr . . h'•J.;•P iP•:q••o r'A•?{%.rr r 0.:.�. �'t,'i•�' 4'ii'i� V�,�ii' V'i'i'r• 'i'ii'i' i'i�'i'��'i'i'i'i' y'i'ii'i' •� i'iV'i'J���Oi'i'i' 'i'i'i'i'��'i'i'i'i'� 'i'i'i'i'' 'i'i'ii' V'r'i'i'H V'i'i'i' `iiii'� i'r'ii',� 0���, ''1� •'' o .1 i' �yr'P�rl �I;r�/�r,��`.•:j 4r` IH it„ 111, „1 �Ifhll 1 111� H f 1111'(� �IIIN fHfl � IIIN��N11� IN� 1y1 Nllf� 1N�1 If�H N�ItiV � 1 �y' , fl�ffl��1i fL��' ��:� ► t{ ! t ttr' try rr� t�{rr trt�lr r4ttr+ nt rt tr{{rr nt{rt rr{{rr tr�trt tt trr' try{rr try{rr �tr►rt n rr t�r il!rt }+ �a,,, 4 Electrical Inspection Certificate _ :u "••�;�,• _ Issue Date Electrical Inspection Service Inc. Application Number 10/22/2007 375 Dunton Avenue 117453C ,, East Patchogue, New York 11772 (631)286-6642 � Issued To: Mr. & Mrs. Thomas Talbot Street: 205 County Road 48r' Ir'r, Village: Mattituck Zip: 11952 Town: Southold wry Section: 113 Block: 0012 Lot: 010.004 `_- Contractor: Ridge Electric Contracting, LLC (L) Lic. # 1895 ,r,•'` ,dew' ..•__ Was examined and found to be in compliance with the National Electrical Code. _ a /F� 'r �w•1.S Cx.l Commercial D NV Defects I- Pool I 11st Floor A Indoor I I Basement 1_. I Hot Tub Residential ❑ Det Garage I _I Attic I 1 2nd Floor lJ Outdoor I. 1 Addition [ Survey T :;w W Switches Receptacles Fixtures GFI Heaters A/C Fans Dishwasher Washer/Amps Dryer/Amps Oven Range/Amps Microwaves Furnace Oil Gas Circulators Smoke Detector Bell Transformer : $ • �— �j Meter Amps Phase UG/OH Jacuzzi Television CO Detector Bldg. Permit: 330602 Other Equipment Photo Voltaic System 10.0 KW �- Hugo S. Surd .' 1-100 amp Raintight Subpanel i� �• -20 amp Inverter Disc./ 1-30 amp Raintight i President Disc. _ Rough Inspection: E Inspector: y-z r.% Final Inspection: 08/01/2007 f. Inspector: John McMahon III This certificate must not be altered in any manner. Inspectors may be identified by their credentials. l+ 1 ► i rr l i r r r►1 it a ii r + i r t=`a, 1,1 , , 1 1 1,41 11, / „1 1,1 1„1 , N , ,1 � rrr t. • 1;+ 1'Ir 1 r /r'� r�l yAr1r'� 11 rl r 111 /r 1;Lr r rrr�•• /rr •••,�irr/ yA,r l /r r �ir'� 1/ •,�y�� �y'� Arr r tiR� ,�ti 'Y•'J�,:•.J Vi-4. • "!`✓•:,.! :,.'>'�J:.•i r':.•S•%••r9�.$yJ�:•;•;A.'r'Pv,.•J,•..J:.:$O!Ir.4.;:.t'r�••'.•,.>�W�f•:y:• 0 '>�4!�'p .r4!S..$::•'�'/•:.•. :�'i''P r:g:y:.V✓S @g�:.'> r'•;q�,•:•.•cM•;.;�;.'>.!�•:.����i�ti�`:,'j��I','•Ii �::;5 ti�.0 4., rr 4'••f •S 1 i �l v:,.•! k Y ;.• ��rJ ''ems;J 4.:; tv�°s 4�;�i t�vl ♦ '' t'%Y� 1 .• �yl 1�,r 'v .•r i�2L :r oF soaryo�o o • ao coutm,��' TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING KFINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS:_,..;'4� ,O�aa� e , v DATE7- INSPECTOR FIELD INSPECTION REPORT DATE I COMMENTS W O � FOUNDATION(1ST) y ------------------------------------- FOUNDATION(2ND)` z � o o . H ROUGH FRAMING& y PLUMBING INSULATION PER N.Y. - -- H STATE ENERGY CODE a-a- a FINAL ADDITIONAL COMMENTS r - o 0 � Z o m � y o O y� � x d ro -� TOWN OF SOUTHOLD PROPERTY RECORD CARD OWNER STREET �j VILLAGE DIST. SUB. LOT 4 �l ACR. _ REMARKS TYPE OF BLD. .� PROP. CLASS qm . ssoc A� LAND IMP. TOTAL DATE 0 .0 ✓A) b' -_ I I ct" C G fit'I / (�Y. lQ 92 1 oc-> l®ao CC) I 11 )Lt - 8 � a.a r7I ti T ` max;: FRONTAGE ON WATER TILLABLE 14� FRONTAGE ON ROAD WOODLAND DEPTH MEADOWLAND ,Zot'0 BULKHEAD r� TOTAL ti / ��17 ■■■■■■■■■■■■■■■■■■■■ • •- ■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■ - ■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■i■■■■MMMMMMMMMMM ■■■ ■■■■■■■■■■■■■■■■■MM Foundation ■■■ '� Interior Finish Fire Place Rooms 1st Floor Rooms 2nd Floor TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL:(631)765-1802 Planning Board approval FAX:(631)765-9502 rr Survey www.northfork.net/Southold/ PERMIT NO. U b � Check Septic Form N.Y.S.D.E.C. Trustees Examined ,20 Contact: Approved ��20 Mail to: Disapproved a/c Phone: Expiration ,20 ut ding ect r 2007 'I APPLICATION FOR BUILDING PERMIT 15 Date ' ,20_PJ INSTRUCTIONS -i-(-,% ,.:a:This application�MUSTlbe completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 ,sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. huh Strom, Use ��� (Signature of applicant or name,if a corporation) 17(aq CR 3R < cop ► /V (Mailing address of applicant)[ State whether applicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber or builder Co n-frucb r- Name of owner of premisest l '� 'e I al��� (As on the tax roll or latest deed) If applicant is a corporation,signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which,proposed work wi ��ll be,d�e: l (�G/! House Number Street J Hamlet County Tax M No. 1000 Section I Block I ?— Lot Subdivision [ (�SC(y C L CA S Filed Map No. Lot (Name) 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy M(Ach lilt; shad b. Intended use and occupancy Ivl 01�11V1Q, c 3. Nature of work(check which applicable):New Building Addition —Alteration Repair Removal Demolition ther Wor (�tar 7 110,t-Qki !l �y� (Description) 4. Estimated Cost T O,SW Fee //� (To be paid on filing this application) 5. If dwelling,number of dwelling units n//"1 Number of dwelling units on each floor If garage, number of cars 6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. t �j� < t 7. Dimensions of exisring structures,if any:Front Rear ,V Depth S Height 2 Number of Stories Dimensions of same structure with alterations or additions: Front cSamt Rear ,Sar'n? Depth 54N'\k Height da,A-,k Number of Stories ,_V6ttr)f 8. Dimensions of entire new construction:Front 5'G. 14-( Rear SAS Depth 5'6Lf ny Height S'aw Number of Stories RW-F goo � 9. Size of lot:Front 15- % Rear 0 5G, Depth `1 t 10.Date of Purchase 2-` 19 C� Name of Former Owner ITS 11.Zone or use district in which premises are situated /n._� 12.Does proposed construction violate any zoning law,ordinance or regulation?YES_NO 13.Will lot be re-graded?YES_NO Will excess fill be removed frrom/fpremises?YES_NO_ 14.Names of Owner of premisesTcN(Ta Address Z�5�-I C`t r Phone No.- / Z P-`k Name of Architect Address Phone No Name of ContractorSL4n I L Address Mod Ck 3q Phone No. ry 3 I-Z us 7 5'o�NMa►�.pd� 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES NO *IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED. b.Is this property within 300 feet of a tidal wetland?*YES NO*— *IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTY OFF ) :&in q-ream 1'�`l� �tCe(l L/ rein-g duly sworn,deposes and says that(s)he is the applicant (Name of individual signing ntract)above named, (S)He is the (o !9 s4 c' 6r (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. Swat fore me this 1, j day of 20(�T V&e i LL 2-�a Notary Public Signature oCWplicant CHRISTINE L. DONATO NOTARY PUBLIC-STATE OF NEW YORK No. 01 D06113407 AUOIIIIOCI In Suffolk County CommIsslon ExplrGs JUIy 26, 2008 Rev II I i II 9Z1`(TYP.)� i 9Z1`(TYP.) i 9ZI`(TYP.)�—- 1 =gig e b°Q��• t E ?a6a 6 1 1 i 0. 1 I I I I I All Zw N'UNIRAC SOLAR MOUNT' RAILS 6 ~ C ? BOLTED TO 'Z' PULINS (TYP.) --� n g -- - _ ---------------J I tr - - - o U) W 1 2 3 4 61 6 7 8 9 10 11 12 13 14 1 F z C m 15 16 17 16 - 191 - 20 - 21 - 22 23 24 26 zs z7 za I LEGEND _ } 1 1 29 30 31 32 _ - - - 39 40_ 41 42 1 I C Y 0 o 0 1 43 44 45 46 471 48 49 50 — — — — — - 1 PROPOSED SOLAR PANEL = m _ INSTALLATION -- -- dr 1 I — — — — -{ — — — — — — — — I POSSIBLE FUTURE SOLAR m �CL 3 1 1 L — J PANEL INSTALLATION ¢ o N w IJ — J — J — — J — — J — — J — J — — J — —_ J � � Co -- _-_ - - - - - - - - - - - - - o � a' lJ ROOF PLAN 4 THIS IS TO CERTIFY THAT WE HAVE CHECKED ALL ALUMINUM MEMBERS TO BE 6105 T5 NOTE: THE ROOF STRUCTURE FOR WIND, SNOW, mse ALLOY. 50 - GE SOLAR PANELS: GEPVp-200 UNBALANCED SNOW, LIVE AMD DEAD LOADS 200 Watts BASED ON ASCE 7-98 AND FOR ALL BOLTS TO BE SAE GRADE 5 STAINLESS Length = 58.5° CONFORMANCE WITH THE NYS BUILDING CODE. STEEL OR BETTER, WITH STAINLESS STEEL WASHERS, PLATES AND NUTS Width = 38.6" THIS ROOF STRUCTURE IS ADEQUATE TO Thickness = 1.4" SUPPORT THE PROPOSED LOADS 07029 S-1 �� L� RCt i i i � � A �: . t �y yf �. _ _... �, n 'i �.. . l �. � , . ��� , ��. 4:,;�� ' ;�:� '� } ..:_ �y �� i "`` �,._�.� � -.Iola V"_ t s s . i County of Suffolk) ss: State of New York) being duly sworn, deposes and says that he/she resides at ®5 /'_�0/d in the County of yfi�� in the State of and that he/she is (owner in fee) (officer of the corporation which is the owner in fee) of the premises in the foregoing application and that he/she has authorized Sun Stream USA, LLC. to make the foregoing application for the building permit as described herein. Owner's Signature S oAblic e this d 20 . Not CHRISTINE L. DONATO NOTARY PUBLIC-STALE OF NEW YORK No. 01 D0611 3407 Qualified In Suffolk County Commlj3lon Expireg July 26, ROOb Seal If a corporation,name of corporation and officer's title Page 4 of 4 — AHE STANDARD IN PV MOUNTING STRUCTUREST" SO RMOUN . U.S.Des.Patent No.D496,2485,D496,249S.Other patents pending. Code-Compliant Planning and Assembly with California Building Code Certification Installation Manual 214 1 :,� �t a 1C{z'w�l + ..',�_. Contents Letter of certification.......................................2 Part I. Scope,certification,and installer responsibility........3 Part H. Procedures for code-compliant installations using the SolarMounO Module Mounting System......4 Part III. Installing SolarMount®with top mounting clamps.....9. Part IV. Installing SolarMount®with bottom mounting clips...15 Warranty................................................20 UniRac welcomes input concerning the accuracy and user friendliness of P.b 0•0 ©2004 by UniRac,Inc. this publication.Please write to publications@unirac.com.' March 2004 All rights reserved. Brian Spring 1 September 2006 Structural Engineering 161 LINDEN LN Mr. Hal Newman MILL VALLEY, CA UniRac,Inc. 94941 Tel:(41 S)497-2880 1411 Broadway Boulevard NE Albuquerque,NM 87102-1545 Subject: Engineering Certification for UniRac's SolarMountTM Universal PV Module Mounting System Dear Mr.Newman, Attached is the UniRac Calculation worksheet and Installation Manual#214,Pub. 040316-1ii, Copyrighted by UniRac,Inc.,March 2004,20 pages. I have reviewed these calculations, and certify their results are accurate. The calculations determine the design level forces for wind, as prescribed .in the California Building Code. The adequacy of the UNIRAC structure is demonstrated by the calculations. The calculations also correctly determine the anchorage requirements for the installation, and this requirement is properly represented in Installation Manual 9214. The calculations are based upon: 1. "The 2001 California Building Code,California Code of Regulations",based on the 1997 "Uniform Building Code,Volume 2: Structural Engineering Design Provisions",by International Conference of Building Officials,Whittier,Ca, 1997,and California Building Standards Commission, Sacramento,California,2001. 2. `Manual of Steel Construction: Load Resistance Factor Design",3rd Ed, American Institute of Steel Construction,Chicago, IL.,2001. 3. "Aluminum Design Manual: Specifications and Guidelines for Aluminum Structures":, The Aluminum Association,Washington D.C.,2000 4. Mechanical Properties of UNIRAC extruded rails and related components based on data obtained from Walter Gerstle,PE,Department of Civil Engineering,University of New Mexico,Albuquerque,NM. With this letter, I certify that UniRac SolarMount products will be structurally adequate and will satisfy the building codes listed above when they are installed per the "SolarMount Code- Compliant Planning and Assembly", Installation Manual #214, Pub. 040316-1ii, Copyrighted by UniRac, Inc., March 2004. The structure to which the UniRac SolarMount system is connected should be evaluated on a .case-by-case basis, per Part I of the Installation Manual, to ensure it's adequacy to accept attachments and to support all applied loadings,per the building code. r Please call me if you have any questi c nee �pEESS! Sincerely, C 2 No. S 61 Brian Spring,PE, SE Exp. 6/ 0/08 sq STRUC?ARP���P Or CA1�4� Installation Manual 214 SolarMount Code-Compliant Planning and Assembly MARA,C® Part I. Scope, certification, and installer responsibility Please review this manual thor- The installer is solely responsible for: oughly before installing your SolarMount system. • Complying with all applicable local or national building codes,including any that may supercede this manual; This manual provides (1) sup- porting documentation for • Ensuring that UniRac and other products are appropri- building permit applications ate for the particular installation and the installation' relating to UniRac s Solar- environment; . Mount' Universal PV Module • Ensuring that the roof,its rafters,connections,and Mounting system, and (2) plan- other structural support members can support the array ning and assembly instructions under building live load conditions (this total assembly for SolarMount. is hereafter referred to as the roof rafter assembly); SolarMount products,when • Using only UniRac parts and installer-supplied parts as installed in accordance with specified by UniRac (substitution of parts may void the this bulletin,will be structur- warranty and invalidate the letter of certification on ally adequate and will meet page 2); the 2001 California Building • Ensuring that lag screws have adequate pullout strength Code and the Uniform Building and shear capacities as installed; Code, 1997,hereafter UBC 1997 . Maintaining the waterproof integrity of the roof,includ- . UniRac also provides a limited warranty on SolarMount prod- ing selection of appropriate flashing; and ucts (see p.20). • Ensuring safe installation of all electrical aspects of the PV array. 3 YNARAW Installation Manual 214 SolarMount Code-Compliant Planning and Assembly Part H. Procedures for code-compliant installations using the SolarMount Module Mounting System This bulletin is designed to support applications for build- 1• Determine the Basic Wind Speed ing permits for installations using SolarMount—PV Module Mounting System,manufactured by UniRac,Inc. at your installation site Follow the six steps below and the installation instructions on For the United States,see"Minimum Basic Wind Speeds in pages 9-20 to install SolarMount in compliance with the 2001 Miles per Hour,"reproduced below. California Building Code and the UBC 1997 If your installation is outside the United States or if you need Before proceeding,note the following: further assistance,consult a local professional engineer or • This bulletin addresses only wind loads on the as- your local building authority. sumption that wind produces the maximum load factor affecting an installation.Verify that other local factors, such as snow loads and earthquake effects,do not ex- ceed the wind loads.Give precedence to any factor that does.Wind loads are considered to act on the entire projected area,or may be perpendicular to any surface. • The roof on which the SolarMount will be installed must have the capacity to resist the combined Design Dead Load and Live Load per footing listed in Tables 2 and 3 on pages 6-7. 100 90 d0 so ` 100y 1 f �° 90 — I ( � 70 —� �r •1 7 1 _...VJ 1 70 „00 — /110 l�y�\` 110 70 17� t PD t —� 70 — — ��-- t 0 wit 110 110 70 g0 901°° RARO WINO SPEEO 70 mph ®SPECIAL WINO REGION `6,1�NL:fl 15 n39 1 0 1 rAUT 1`!S£11PO1tlt92OCM7IN WlllO`.PCCD OONTWnSL'ACC•TpOLE. 10 x caur�' Ke+Ir<us Rccvn;vE n:rsMIs�rsEu. ]YICt0 WEED FOR IIAIV>W K CM.-O r 9.OSMIEF E w E C IRAel IR A:) _ •.WCIO SEED VhV PE/SSl.1EC 102E CO:XiTA`I(@£T:'IEF.'�ME COA.RtUnE M')TNF.M1EAfL61 L•.LYi] _CUR. Figure 1.Minimum Basic Wind Speeds.Reproduced from UBC,Vol.2,Structural Engineering Design provisions, Chap.16,Div.III,Wind Design,Fig.16.1,`Minimum Basic Wind Speeds in Miles per Hour,"p.36.The map has been adopted by the 2001 California Building Code(Fig.16-1,vol 2.p.36). Pap 4 Installation Manual 214 SolarMount Code-Compliant Planning and Assembly UNMMC' 2. Determine the exposure category Table 1.Design Wind Pressure(psQ of your installation site by Wind Speed and Exposure Category The California Building Code*defines wind exposure catego- Design force applies to surface pressure and/or uplift(withdrawal). ries as follows: Basic Wind Speed(mph) ExrosoxE B has terrain with buildings,forests or sur- 70 80 90 100 110 120 130 face irregularities,covering at least 20 percent of the Category B ground level area extending 1 mile(1.61 km)or more 15'roof height 10 13 17 21 25 30 35 from the site. 20'roof height 11 14 18 22 27 32 38 ExrosuRE c has terrain that is flat and generally open, 25'roof height 12 15 19 24 29 35 41 extending Y2 mile(0.81 km)or more from the site in 30'roof height 12 16 21 25 31 36 43 any quadrant or having scattered obstructions extending Category C one-half mile or more from the site in any full quadrant. 15'roof height 17 23 29 35 43 51 60 This category includes flat orgently rolling open country 20'roof height 19 24 31 38 46 54 64 and grasslands.Sites normally considered as Exposure 25'roof height 19 25 32 40 48 57 67 B,but which are subject to topographic amplification 30'roof height 20 26 33 41 50 59 69 or channelization,such as ridgetops or draws,shall be considered as Exposure C.t Category D 15'roof height 23 30 38 46 56 67 78 ExrosunE D represents the most severe exposure in ar- 20'roof height 24 31 39 48 58 70 82 eas with basic wind speeds of 80 miles per hour(mph) 25'roof height 25 32 41 50 60 72 84 (129 km/h)or greater and has terrain that is flat and 30'roof height 25 33 42 51 62 74 87 unobstructed facing large bodies of water over 1 mile (1.61 km)or more in width relative to any quadrant of Source These Design Wind Pressure(P)values are based on the formula P=C C *qs*I (2001 California Building Code,vol.2,chap.16,Structural the building site.Exposure D extends inland from the Engineering Design Provisions,Div.III,Wind Design,p.38.10).Assump- shoreline t/a mile(0.40 km)or 10 times the building bons:l =1 and C =1.3. height,whichever is greater. 3. Determine Design Wind Pressure 4a.Determine Minimum Design Dead required for your installation and Live Loads for standard rafter Design Wind Pressure is the amount of wind pressure that a spacing structure is designed to withstand,expressed here in pounds Foot spacing refers to the space between L-feet(or standoffs,if per square foot(psf).To determine the Design Wind Pressure applicable)along the same SolarMount rail(see Fig.2,p.8). required for your installation,apply the following factors using If you are spacing feet to match a standard rafter spacing,con- Table 1: sult Table 2 to determine your Minimum Design Live and Dead • your Basic Wind Speed(determined in step 1). Loads per footing.(If you prefer to maximize foot spacing to minimize roof penetrations,skip to Step 0 on p.8.) • your exposure category(determined in step 2),and Locate the make and model of the PV module that you plan to • the height of your roof above the ground. install and the rafter spacing at your installation site.Read the If your values fall significantly outside the range of the table, Minimum Design Dead Load and read or extrapolate the Mini- or if your Design Wind Pressure requirement exceeds 50 psf, mum Design Live Load for the Maximum Foot Spacing and the consult UniRac,a professional engineer,or your local building Design Wind Pressure you determined in step 3. authority. To meet code,you must verify that the roof rafter assembly at your installation site has the capacity to resist the sum of the Design Dead and Live Loads. *2001 California Building Code,vol.2,chap.16,Structural Engineer- ing Design Provisions,Div.III,Wind Design,p.38.10. If they do not,try smaller footer spacing.(In this case,you may )Emphasis in the original,indicating material inserted by California elect to use the procedures outlined in Step 4b.)If the result into definitions adopted from the UBC. is still not acceptable,relocate the array to a stronger area of the roof or strengthen the inadequate framing elements.For assistance,consult a local professional engineer. Go to step 5 on page S. NP 5 UN®I V Installation Manual 214 SolarMount Code-Compliant Planning and Assembly Table 2.SolarMountTm Loads (lbs) per Footing at Standard Rafter Spacings To meet code,your Design Loads must beat or above those indicated.You,the installer,are solely responsible for verifying that the roof can withstand these design loads.For specifications based on Design Wind Pressure values greater than 50 pounts per square foot,contact UniRac. Minimum Design Live Load as a Minimum Design Live Load as a Minimum Function of Design Wind Pressure Minimum Function of Design Wind Pressure Design Design Dead Load 20 psf 30 psf 40 psf 50 psf Dead Load 20psf 30 psf 40 psf 50 psf AstroPowerAP65,AP75 RWE Schott ASE 300 48"rafter(foot)spacing 33 157 236 315 393 48"rafter(foot)spacing 58 248 373 497 621 64"rafter(foot)spacing 43 210 315 420 524 64"rafter(foot)spacing 77 331 497 662 828 72"rafter(foot)spacing 49 236 354 472 590 72"rafter(foot)spacing 87 373 559 745 NA AstroPower APi I IO,APi120 RWE Schott SAPC165(See Sharp NE-165U1) 48"rafter(foot)spacing 33 194 291 387 484 Sanyo HIT190 64"rafter(foot)spacing 44 258 387 516 646 48"rafter(foot)spacing 29 173 260 347 433 72"rafter(foot)spacing 50 291 436 581 726 64"rafter(foot)spacing 39 231 347 462 578 Astro owerAPi165 72"rafter(foot)spacing 44 260 390 520 650 48"rafter(foot)spacing 31 194 291 387 484 Sharp NE-BOUI 64"rafter(foot)spacing 41 258 387 516 646 48"rafter(foot)spacing 33 158 237 315 394 72"rafter(foot)spacing 46 291 436 581 726 64"rafter(foot)spacing 44 210 315 420 526 BP Solar 375,380,580,585 72"rafter(foot)spacing 49 237 355 473 591 48"rafter(foot)spacing 31 158 237 316 395 Sharp ND-123UI 64"rafter(foot)spacing 41 211 316 421 527 48"rafter(foot)spacing 38 197 295 393 492 72"rafter(foot)spacing 46 237 356 474 593 64"rafter(foot)spacing 50 262 393 525 656 BP Solar 3125 72"rafter(foot)spacing 56 295 443 590 738 48"rafter(foot)spacing 33 198 297 396 495 Sharp ND-NOECU(140W) 64"rafter(foot)spacing 44 264 396 528 660 48"rafter(foot)spacing 26 153 230 306 383 72"rafter(foot)spacing 50 297 446 594 743 64"rafter(foot)spacing 34 204 306 408 510 BP Solar 3160,4150,4160,4170 72"rafter(foot)spacing 39 230 344 459 574 48"rafter(foot)spacing 33 209 314 418 523 Sharp NE-165U I,NT 175U I,NT 185U 1 64"rafter(foot)spacing 44 279 418 557 697 48"rafter(foot)spacing 35 207 310 413 517 72"rafter(foot)spacing 50 314 470 627 784 W rafter(foot)spacing 47 276 413 551 689 Evergreen EC 102,EC 110,EC 115 72"rafter(foot)spacing 53 310 465 620 775 48"rafter(foot)spacing 35 208 312 416 520 Sharp ND-I67U1 64"rafter(foot)spacing 46 277 416 555 693 48"rafter(foot)spacing 28 174 262 349 436 72"rafter(foot)spacing 52 312 468 624 780 64"rafter(foot)spacing 37 232 349 465 581 First Solar FS50D 72"rafter(foot)spacing 41 262 392 523 654 48"rafter(foot)spacing 35 158 236 315 394 Shell SM 110 64"rafter(foot)spacing 47 210 315 420 525 48"rafter(foot)spacing 32 173 259 345 432 72"rafter(foot)spacing 52 236 354 473 591 64"rafter(foot)spacing 43 230 345 460 576 Kyocera KC80 72"rafter(foot)spacing 49 259 389 518 648 48"rafter(foot)spacing 29 128 192 256 320 Shell SQ70,SQ75,SQ80 64"rafter(foot)spacing 39 171 256 341 427 48"rafter(foot)spacing 31 157 236 315 393 72"rafter(foot)spacing 44 192 288 384 480 64"rafter(foot)spacing 41 210 315 420 524 Kyocera KC 120,KC 125G 72"rafter(foot)spacing 46 236 354 472 590 48"rafter(foot)spacing 34 187 281 374 468 Shell SQ 140,SQ 150,SQ 160 64"rafter(foot)spacing 45 249 374 499 623 48"rafter(foot)spacing 36 213 320 426 533 72"rafter(foot)spacing 51 281 421 561 701 64"rafter(foot)spacing 48 284 426 568 710 Kyocera KC I S8G,KC I67G 72"rafter(foot)spacing 54 320 479 639 NA 48"rafter(foot)spacing 28 169 254 339 423 SunWize SW85,SW90,SW95 64"rafter(foot)spacing 37 226 339 452 564 48"rafter(foot)spacing 35 190 285 380 474 72"rafter(foot)spacing 42 254 381 508 635 fi4"rafter(foot)spacing 46 253 380 506 633 Photowatt PW750 72"rafter(foot)spacing 52 285 427 569 712 48"rafter(foot)spacing 30 162 244 325 406 SunWize SW 115,SW 120 64"rafter(foot)spacing 40 216 325 433 541 48"rafter(foot)spacing 34 190 285 380 474 72"rafter(foot)spacing 45 244 365 487 609 64"rafter(foot)spacing 45 253 380 506 633 Photowatt PW 1250 72"rafter(foot)spacing 51 285 427 569 712 48"rafter(foot)spacing 30 163 245 327 409 UniSolar 64 64"rafter(foot)spacing 39 218 327 436 545 48"rafter(foot)spacing 25 179 269 359 448 72"rafter(foot)spacing 44 245 368 490 613 64"rafter(foot)spacing 33 239 359 478 598 Photowatt PW 1650 72"rafter(foot)spacing 37 269 403 538 672 48"rafter(foot)spacing 31 162 244 325 406 64"rafter(foot)spacing 41 216 325 433 541 72"rafter(foot)spacing 46 244 365 487 609, Page 6 Installation Manual214 SolarMount Code-Compliant Planning and Assembly UmBRAc® Table 3.SolarMountTm Loads per Footing at Maximum Foot Spacing To meet code,your Design Loads must beat or above the Design Wind Pressure indicated.You,the installer,are solely responsible for verifying that the roof can withstand these design loads.For specifications based on Design Wind Pressure values greater than 50 pounds per square foot,contact UniRac, Design Wind Pressure Design Wind Pressure 20 psf 30 psf 40 psf 50 psf 20 psf 30 psf 40 psf 50 psf AstroPowerAP65,AP75 RWE Schott ASE 300 Maximum Foot Spacing(inches) 131 107 93 83 Maximum Foot Spacing(inches) 104 85 74 66 Minimum Foot Design Live Load(lbs) 429 526 610 680 Minimum Foot Design Live Load(lbs) 538 660 766 054 Minimum Foot Design Dead Load(Ibs) 89 73 63 56 Minimum Foot Design Dead Load(Ibs) 126 103 89 80 AstroPower APi I 10,AN 120 RWE Schott SAPC165(See Sharp NE-165U1) Maximum Foot Spacing(inches) 118 96 83 75 90 Minimum Foot Design Live Load(Ibs) 476 581 670 757 Sanyo Foot Minimum Foot Design Dead Load(lbs) 82 67 58 52 Maximuumm F Foot Spacing(inches) 1 102 88 79 Minimum Foot Design Live Load(lbs) 45151 553 636 713 AstroPower API 165 Minimum Foot Design Dead Load(lbs) 76 62 54 48 Maximum Foot Spacing(inches) 118 96 83 75 Minimum Foot Design Live Load(lbs) 476 581 670 757 Sharp I Minimum Foot Design Dead Load(lbs) 75 61 53 48 Maximuumm Foot Spacing(inches) 131 107 92 83 Minimum Foot Design Live Load(Ibs) 430 527 604 682 BP Solar 375,380,580,585 Minimum Foot Design Dead Load(lbs) 90 73 63 57 Maximum Foot Spacing(inches) 131 107 92 83 Minimum Foot Design Live Load(lbs) 431 528 606 683 Sharp ND-123U1 Minimum Foot Design Dead Load(Ibs) 84 68 59 53 Maximum Foot Spacing(inches) 117 96 83 74 Minimum Foot Design Live Load(lbs) 480 590 680 758 BP Solar 3125 Minimum Foot Design Dead Load(lbs) 92 75 65 58 Maximum Foot Spacing(inches) 117 95 82 74 Foot Sp ci Minimum Foot Design Live Load(Ibs) 483 588 677 763 Sharp N (140W) Minimum Foot Design Dead Load(lbs) 81 65 56 51 Maximum F Foot Spacing(inches) 1 108 94 84 Minimum Foot Design Live Load(lbs) 42424 516 599 669 BP Solar 3160,4150,4160,4170 Minimum Foot Design Dead Load(lbs) 72 58 51 45 Maximum Foot Spacing(inches) 114 93 80 72 Sharp NE-I 651.1 I,NT 175U 1,NT 185U 1 Minimum Foot Design Live Load(lbs) 496 607 697 784 Minimum Foot Design Dead Load(lbs) 79 64 55 50 Maximum Foot Spacing(inches) 114 81 72 Minimum Foot Design Live Load(lbs) 491 60101 698 775 Evergreen EC 102,EC 110,EC 115 Minimum Foot Design Dead Load(lbs) 83 68 59 53 Maximum Foot Spacing(inches) 114 93 80 72 Minimum Foot Design Live Load(lbs) 494 605 693 780 Sharp ND-167UI Minimum Foot Design Dead Load(Ibs) 82 67 58 52 Maximum Foot Spacing(inches) 1 102 88 79 Minimum Foot Design Live Load(Ibs) 45050 556 639 717 First Solar FS50D Minimum Foot Design Dead Load(lbs) 71 58 50 45 Maximum Foot Spacing(inches) 131 107 92 83 Minimum Foot Design Live Load(lbs) 430 527 604 661 Shell SM 110 Minimum Foot Design Dead Load(lbs) 95 78 67 60 Maximum Foot Spacing(inches) 125 102 88 79 Minimum Foot Design Live Load(lbs) 450 550 633 710 Kyocera KC80 Minimum Foot Design Dead Load Qbs) 84 69 59 53 Maximum Foot Spacing(inches) 145 118 103 92 Shell SQ70,SQ75,SQBO Minimum Foot Design Live Load(lbs) 387 472 549 613 Minimum Foot Design Dead Load(lbs) 88 72 63 56 Maximum Foot Spacing(inches) 131 107 93 83 Minimum Foot Design Live Load(lbs) 429 526 610 680 Kyocera KC 120,KC125G Minimum Foot Design Dead Load(lbs) 84 69 60 53 Maximum Foot Spacing(inches) 120 98 85 76 Shell SQ 140,SQ I SO,SQ 160 Minimum Foot Design Live Load(lbs) 468 573 662 740 Minimum Foot Design Dead Load(lbs) 85 69 60 54 Maximum Foot Spacing(inches) 112 92 80 71 Minimum Foot Design Live Load(lbs) 497 612 710 788 Kyocera KC I S8G,KC 167G Minimum Foot Design Dead Load(lbs) 84 69 60 53 Maximum Foot Spacing(inches) 126 103 89 80 Minimum Foot Design Live Load(lbs) 445 545 628 706 Sun Maximum Foot S SW90,SW95 Minimum Foot Design Dead Load(Ibs) 73 60 52 46 Maximum Foot Spacing(inches) 119 97 84 75 Minimum Foot Design Live Load(Ibs) 470 575 664 741 Photowatt PW750 Minimum Foot Design Dead Load(lbs) 86 70 61 54 Maximum Foot Spacing(inches) 129 105 91 81 Minimum Foot Design Live Load(lbs) 436 533 616 685 Sun mu Foot 115,SW 120 Minimum Foot Design Dead Load(lbs) 80 65 57 50 Maximum oc Spacing(inches) 119 97 64 75 Minimum Foot Design Live Load(lbs) 470 575 664 741 Photowatt PW 1250 Minimum Foot Design Dead Load(lbs) 84 69 59 53 Maximum Foot Spacing(inches) 128 105 91 81 Minimum Foot Design Live Load(lbs) 436 536 620 689 U ax r 64 Maxim Minimum Foot Design Dead Load(lbs) 79 65 56 50 Maximum Foot Spacing(inches) 1 100 87 78 Minimum Foot Design Live Load(lbs) 45959 560 650 728 Photowatt PW 1650 Minimum Foot Design Dead Load(lbs) 64 52 45 40 Maximum Foot Spacing(inches) 129 105 91 81 Minimum Foot Design Live Load(lbs) 436 533 616 685 Minimum Foot Design Dead Load(lbs) 83 68 59 52 ftr 7 UNNMW Installation Manual 214 SolarMount Code-Compliant Planning and Assembly 4b. . . . Or verify Maximum Foot If they do not,try smaller footer spacing.If the result is still not acceptable,relocate the array to a stronger area of the roof or Spacing and Determine Minimum strengthen the inadequate framing elements.For assistance, Design Dead and Live Loads consult a local professional engineer. To minimize roof penetrations,consult Table 3(p.7)to deter- 5. Verify acceptable Rail End Overhang mine Maximum Foot Spacing allowable for the Design Wind Pressure that you determined in Step 3. Rail End Overhang(Fig.2)must equal 50 percent or less of Find the make and model of the PV module you plan to install, foot spacing.Thus,if foot spacing is 72 inches,the Rail End then read or extrapolate Foot Design Live Loads and Dead Overhang can be up to 36 inches.In this case,two feet can Loads at the maximum spacing. support a rail of as much as 144 inches(72 inches between the feet and 36 inches of overhang at each end). To meet code,you must verify that foot spacing is at or below the dimension listed and that the roof rafter assembly at 6. Ensure that Live Loads do not your installation site has the capacity to withstand the stem exceed Pull-Out Capacities of the Design Dead Load and Design Live Load for the speci- fied spacing. Based on the characteristics of your roof rafter or truss lumber and the lag screws,consult Table 4 to determine the lag pull- out capacity per 1-inch thread depth.Compare that value to the minimum design live load per footing determined in Step 4a or 4b.Based on these values,determine the length of the lag-screw thread depth you require to resist the design live load.To ensure code compliance,the lag / pull-out capacity per footing must be greater than the footing design live load. If your SolarMount requires standoffs,always SolarMount use at least two lag screws to secure the foots pacing Overhang standoff to the rafter. P g m: Figure 2.SolarMountfoot spacing refers to the distance between feeton the same raiL over- hang,the distance from end of the rail to the first foot,maybe no more than half the footspacing. Table 4.Lag pull-out(withdrawal) capacities (lbs) in typical roof truss lumber Lag screw specifications Specific %-shaft* s/b" shaft* '/e"shaft* gravity 2%:"thread depth per I"thread depth per I"thread depth Douglas Fir,Larch 0.50 665 266 304 Douglas Fir,South 0.46 588 235 269 Engelmann Spruce,Lodgepole Pine (MSR 1650 f &higher) 0.46 588 235 269 Hem,Fir 0.43 530 212 243 Hem,Fir(North) 0.46 588 235 269 Thread depth Southern Pine 0.55 768 307 352 Spruce,Pine,Fir 0.42 513 205 235 _ Spruce,Pine,Fir (E of 2 million psi and higher grades of MSR and MEL) 0.50 665 266 304 Sources:Uniform Building Code;American Wood Council. Notes:(1)Thread must be embedded in a rafter or other structural roof member. (2)Pulkut values incorporate a 1.6 safety factor recommended by the American Wood Council. (3)See UBC for required edge distances. *Use Pat washers with lag screws. r.V 8 Installation Manual 214 SolarMount Code-Compliant Planning and Assembly UNNI AC' Part III. Installing SolarMount with top mounting clamps This section covers SolarMount , assembly where the installer has elected to use top mount- ing clamps to secure modules to the rails.It details the procedure for flush mounting SolarMount to a pitched roof. /� ,,- i- • Contents Laying out the \�•„ �� >.d' .\ installation area.......... 10 Laying out L-feet ......... 11 :.. / `� Installing L-feet .......... 11 Laying out standoffs ...... 12 Installing standoffs ....... 12 Installing SolarMount rails .................... 13 Installing the modules..... 14 Mid r Clamp 'N `a �o 9b SolorMount rail "ZI\ �,• ' r�End • °�, �L-foot i, � � Figure 3.Exploded view of a low profile installation mounted flush to the roof with L feet. Table 5.Part quantities Table 6.Wrenches and torque SMR Series SolarMount Rail Sets(model no.=rail length in inches) Wrench Recommended Y8"footing '/.-flange size torque(ft4bs) Rails L-feet bobs nuts %,-hardware 'Ilc 15 SMR48 thru 106 2 4 4 4 '/a- hardware °/b- 30 SMR120 thru 180 2 6 6 6 SMR192 thru 216 2 8 8 8 CT Series Clamp Sets(model no.=modules accommodated) End Mid %,-module /,-x%- A-flange Stainless steel hardware can seize up, clamps clamps clamp bobs safety bolts nuts a process called galling.To significantly CT2 4 2 6 2 8 reduce its likelihood,(1)apply lubri- CT3 4 4 8 2 10 cant to bolts,preferably an anti-seize lubricant, CT4 4 6 10 2 12 available at auto parts stores,(2)shade hardware CT5 4 8 12 2 14 prior to installation,and(3)avoid spinning on nuts at high speed.See Installation Supplement CT6 4 10 14 2 16 910,Galling and Its Prevention,at www.unirac.com. CT7 4 12 16 2 18 CT8 4 14 18 2 20 Pag 9 UNNIMC' Installation Manual 214 SolarMount Code-Compliant Planning and Assembly Laying out the installation area The width of the installation area is equal to the length of one The installation can be laid out with rails parallel to the rafters module. (high-profile mode)or perpendicular to the rafters(low-pro- The length of the installation area is equal to: file mode).Note that SolarMount rails make excellent straight • the total width of the modules, edges for doing layouts. • plus 1 inch for each space between modules(for mid- Center the installation area over the rafters as much as pos- clamp), sible. • plus 3 inches(11/a inches for each set of end clamps). Leave enough room to safely move around the array during installation. Low-profile High-profile mode mode 4 Figure 4.Rails may beplacedparallel orperpendicular to rafters. 10 Installation Manual 214 SolarMount Code-Compliant Planning and Assembly UNNRAC° 63 Laying out L feet L-feet(Fig.5)are used for installation through existing roofingmaterial such as asphalt shingles or sheet metal. P g Use Figure 6 or Figure 7 below to locate and mark the L-feet lag bolt holes within the installation area. To meet code,you must use the foot spacing deter- mined in procedural steps 4a or 4b(pp.5,8). Figure 5 When determining the distance be- Overhang 25%typical tween the rails in high-profile mode, � , Foot spacing each end keep in mind that the center of each rail will be offset from the L-foot lag bolt holes by 13/4 inches. if multiple high-profile rows are to be 5017otypical installed adjacent to one another,it 1 will not be possible for each row to be centered above the rafters. Adjust as needed,following the guidelines in Lower roof edge Figure 7 as closely as possible. r Rafters Figure 6.Low profile layout 25%maximum 50%minimum typical typical each end I� 11 �tI it Foot �. spacing I I 1 I II Lower roof edge i I�i �I Overhang Rafters Figure 7.High-profile layout InstaIiing L feet Drill pilot holes through the roof into the center of the rafter at each L-foot lag bolt hole location. Consult procedural step 6 and Table 4(p.8)to select the lag bolts that you must use to meet building code wind load requirements.Lag bolts are not provided with SolarMount rail sets. Squirt sealant into the hole,and on the shafts of the lag bolts.Seal the underside of the L-feet with a suitable weatherproof sealant. Securely fasten the L-feet to the roof with the lag bolts. Ensure that the L-feet face as shown in Figure 6 or Figure 7.The single-slotted square side of the L-foot must always he against the roof with the double-slotted side perpendicular to the roof. 11 UNAMW Installation Manual 214 SolarMount Code-Compliant Planning and Assembly Laying out standoffs Standoffs(Fig.8)are used for flashed installations,such as those with tile and shake shingles. Use Figure 9 or Figure 10 to locate and mark the standoff lag bolt holes within the installation area. To meet code,you must use the foot spacing determined in procedural steps 4a or 4b(pp.5,8). Remove the file or shake underneath each standoff location,exposing the roofing underlayment.Ensure that the standoff base lies flat on the underlayment,but remove no more material than required for the flashings to be installed properly. Use the standoff base as a template to mark lag bolt hole locations on underlayment above the center of the rafters(Fig.9 or Fig.10). Overhang .✓ 25%typical I<—Foot spacing -�. n each end F ! i; 50%minimum i typical - Lower roof edge �y Figure 8.Raised flange _ _f Rafters standoff(left)and flat top standoff used in con- junction with an L-foot. Figure 9. Low-profde layout 257o typical 50%minimum 6. When determining the distance be- each end -° -��� typical �� t tween the rails in high-profile mode, t. keep in mind that the center of each rail will be offset from the standoff lag bolt �h e" holes b '/6 of an inch. If multiple high-profile rows are to be installed adjacent to each other, i; it will not be possible for each row to o p at be centered above the rafters. Adjust ' spacing as needed following the guidelines in i Figure 10 as closely as possible. i GOverhang Lower roof edge I Rafters Figure 10.High profile layout Installing standoffs Ensure that the standoffs face as shown in Figure 9 or Drill 3/i6-inch pilot holes through the underlayment Figure 10. into the center of the rafters at each standoff location. SolarMount steel standoffs(1s/8"O.D.)are designed Securely fasten each standoff to the rafters with the two for collared flashings available from UniRac.Aluminum 5/16"x 3'/3"lag bolts provided with it. two-piece standoffs(11/8"O.D.)take all-metal flash- Note:You must verify that the lag bolts you use are ings,also available from UniRac. adequate for your installation by following proce- install and seal flashings and standoffs using standard dural steps 4A or 4B(pp.5,8). building practices. Page 12 Installation Manual 214 SolarMount Code-Compliant Planning and Assembly 11NOMC° Installing SolarMount rails / Keep rail slots free of roofing grit or other debris. Foreign matter will cause bolts to bind as they slide in the slots. i Installing Splices.If your installation uses ii SolarMount splice bars,attach the rails together (Fig.11)before mounting the rails to the foot- ings. Use splice bars only with flush installations or those that use low-profile tilt legs. If using more than one splice per rail,contact UniRac concerning thermal expansion issues. Figure 11.Splice bars slide into the footing bolt slots of SolarMount rail sections. Mounting Rails on Footings.Rails may be Clamping attached to either of two mounting holes in the bolt slot �� r footings(Fig.12).Mount in the lower hole for a r�. aesthetically pleasing instal- lation.profile,more y p g lation. Mount in the upper hole for a higher profile,which will maximize airflow under the Mounting modules.This will cool them more and may Footing slots enhance performance in hotter climates. bolt slot �. Slide the%-inch mounting bolts into the footing bolt slots. Loosely attach the rails to the footings tFlc'J with the flange nuts. Ensure that the rails are oriented to the footings as shown in Figure 6,7,9,or 10,whichever is Figure 12.Foot-to-rail splice attachment appropriate. Aligning the Rail Ends. Align one pair of rail ends to the edge of the instal- - - lation area(Fig.13 or Fig. 14). The opposite pair of rail ends will overhang the side of the installation area.Do not trim them off until the installation is l I complete. In low-profile mode(Fig. 13),either end of the Edge of installation area Edge of installation area rails can be aligned,but the first module must be Figure 13.Low profile mode Figure 14.High profile mode installed at the aligned end. For the safest high-profile installation(Fig.14),the aligned end of the rails must face the lower edge of the roof.Securely tighten the flange nuts on the mounting bolts after alignment is complete(28-32 ft lbs). Mount modules to the rails as soon as possible.Temperature changes may bow the rails within a few hours if module placement is delayed. P.m 13 1111®1$ W Installation Manual 214 SolarMount Code-Compliant Planning and Assembly Installing the modules Prewiring Modules.If modules are the Plug and Play type,no prewiring is Module required,and you can proceed directly to"Installing the First Module"below. /_'minimum -frame If modules have standard J-boxes,each module should be prewired with one I� end of the intermodule cable for ease of installation.For safe reasons,module a module bolt n' - and flange'nut prewiring should not be performed on the roof. Leave covers off J-boxes.They will be installed when the modules are installed on the rails. 'Rail:.^ Installing the First Module.In high-profile installations,the safety bolt and End clamp. flange nut must be fastened to the module bolt slot at the aligned(lower)end of each rail.It will prevent the lower end clamps and damping bolts from sliding out of the rail slot during installation. Figure 15 If there is a return cable to the inverter,connect it to the first module.Close the J-box cover.Secure the first module with T-bolts and end damps at the aligned end of each rail.Allow half an inch between the rail ends and the end clamps (Fig.15).Finger tighten flange nuts,center and align the module as needed,and securely tighten the flange nuts(15 ft lbs). Installing the Other Modules.Lay the second module face down(glass to glass)on the first module.Connect intermodule cable to the second module and s/ r dose the J-box cover.Turn the second module face u (Fig.16).With T-bolts, -- ` mid damps,and flange nuts,secure the adjacent sides of the first and second J-boxes modules.Align the second module and securely tighten the flange nuts(Fig.17). For a neat installation,fasten cable damps to rails with self-tapping screws. Figure 16 Repeat the procedure until all modules are installed.Attach the outside edge of the last module to the rail with end clamps. .v _ Module frames Trim off any excess rail,being careful not to cut into the roof.Allow half an inch between the end clamp and the end of the rail(Fig.15). Check that all flange nuts on T-bolts are securely fastened. 6 module bolt g Y � , , x and flange nut IT4 i • � ��ry•Rail ¢- Mid clamp . Figure 17 High-lipped module Spacer 7aLow-lipped module (cross section) (cross section) SolarMount rail S SolarMount rail Figure I&Mid clamps and end clamps for lipped frame modules are identical.A spacer for the end clamp is necessary only if lips are located high on the module frame. 14 Installation Manual 214 SolarMount Code-Compliant Planning and Assembly VNOMC° Part IV. Installing SolarMount with bottom mounting clips This section covers SolarMount assembly where the installer has elected to use bottom mounting clips to secure modules to the rails.It de- tails the procedure for flush mount- ing SolarMount to a pitched roof. Contents �`� \'\� Yv modules(face down) \' \ Planning the installation area.... 16 Laying out and installing L-feet ..17 Attaching modules to the rails... 18 Installing module-rail assembly.. 19 ~ / SolorMouni rail Fooling bolt slot 4 Bottom mounting clip Figure 19.SAM and CB components Table 7.Part quantities Table 8.Wrenches and torque SMR Series SolarMount Rail Sets(model no.=rail length in inches) Wrench Recommended size torque(ft-lbs) footing '/e"flange Rails L-feet bolts nuts Y4" hardware %6" 15 '/a-hardware %6" 30 SMR48 thru 106 2 4 4 4 SMR120 thru 180 2 6 6 6 SMR192 thru 216 2 8 8 8 CB Series Clip Sets(model no.= modules accommodated) '/."module Y4" flange Clips bolts nuts Stainless steel hardware can seize up, ' a process called galling.To significantly CB2 8 8 8 • reduce its likelihood,(1)apply lubri- CB3 12 12 12 cant to bolts,preferably an anti-seize lubricant, C64 16 16 16 available at auto parts stores,(2)shade hardware CB5 20 20 20 prior to installation,and(3)avoid spinning on CB6 24 24 24 nuts at high speed.See Installation Supplement C87 28 28 28 910,Galling and Its Prevention,at www.unirac.com. C138 32 32 32 Page 15 UNNM .`® Installation Manual 214 SolarMount Code-Compliant Planning and Assembly Planning the installation area Distance between Decide on an arrangement for clips,rails,and L-feet lag bolt centers 2"--► 2„ (Fig.20). Distance between Use Arrangement A if the full width of the rails module mounting holes contact the module.Otherwise use ArrangementB. Caution:Ifyou choose Arrangement B,either PV module 0 (1)use the upper mounting holes of the L-feetor (2)be certain that the L-feet and clip positions don't ti conflict. Module bolt Clip If rails must be parallel to the rafters,it is unlikely i. Rail L-toot—y R o i I that they can be spaced to match rafters.In that case, 1 add structural supports—either sleepers over the - roof or mounting blocks beneath it.These additional -.--log bolt members must meet code;if in doubt,consult a pro- fessional engineer. Distance between Never secure the footings to the roof decking alone. .—lag bolt centers /4"-. -�. •-I/4" Such an arrangement will not meet code and leaves Distance between the installation and the roof itself vulnerable to severe module mounting holes damage from wind.Secure the footings in accordance with"Installing L-feet"(p.11). i Leave enough room to safely move around the array during installation.The width of a rail-module as- sembly equals the length of one module.Note that L-feet may extend beyond the width of the assembly . by as much as 2 inches on each side.The length of the assembly equals the total width of the modules. Figure 20.Clip Arrangements A and B ro� 16 Installation Manual 214 SolarMount Code-Compliant Planning and Assembly WRAC° Rafters Laying out and Install later Install later installing L feet -- - -: - ------- - -------- J ----= 1 IM L-feet are used for installation through e3dsting low profile roofing i i material,such as asphalt shingles or sheet metal.They are also used for 1 1 I 1 1 1t 1 ': II most ground mount installations.To 1 [ I t 1 1 ensure that the L-feet will be easily accessible during flush installation: Rails 11 I�t • Use the PV module mounting II It II holes nearest the ends of the i 1 modules. If IE ! I • Situate the rails so that foot- ing bolt slots face outward. Use Figure 20 to determine spacing _ L _� between feet on opposite rails. __.>._ _- Lower _�V Foot spacing(along the same rail) _ roof and rail overhang depend on design Insi all now edge wind loads. To meet code,you must use the foot Figure 21.Rails laid out perpendicular to the rafters. spacing determined in procedural steps 4a or 4b(pp.5,8). Install half the L-feet: • If rails are perpendicular to Rafters rafters(Fig.21),install the feet closest to the lower edge i r of the roof. Mounting i" " block • If rails are parallel to rafters (Fig 22),install the feet for one of the rails,but not both. _ c For the L-feet being installed now, drill pilot holes through the roof into the center of the rafter at each lag bolt hole location.Consult Table 4(p. Install ' ;; Install 8)to select lag bolts to meet design L-feet I I � L-feet �- wind loads. now ;� i later Squirt sealant into the hole and onto the shafts of the lag bolts.Seal the E underside of the L-feet with a weath- erproof sealant.Securely fasten the L-feet to the roof with the lag bolts. i L-________ Ensure that the L-feet face as shown ~ - II i in Figure 21 or Figure 22. '; ii i Mounting Hold the rest of the L-feet and fasten- ;• —Rails-„—► block h I� ers aside until the panels are com- plete and ready for installation. Figure M.Rails laid out parallel to the rafters. par 17 UNOM .j° Installation Manual 214 SolarMount Code-Compliant Planning and Assembly Attaching modules to the rails Lay the modules for a given panel face down on a surface that will not damage the module glass.Align the edges of the modules and snug them together(Fig.19,p.15). Trim the rails to the total width of the modules to be mounted.Place a rail adjacent to the outer mounting holes.Orient the footing bolt slot outward.Place a clip slot adjacent to the mounting holes,following the arrangement you selected earlier(Fig.20a or 20b,p.16). Assemble the clips,mounting bolts,and flange nuts.Torque the flange nuts to 15 foot- pounds. Wire the modules as needed.For safety reasons,module wiring should not be performed on a roof.For a neat installation,fasten cable clamps to rails with self-tapping screws. Page 18 Installation Manual 214 SolarMount Code-Compliant Planning and Assembly WRAce Installing the module-rail assembly • Mount in the lower hole for a low,more aesthetically pleasing installation. Bring the module-rail assembly to the installation site.Keep . Or mount in the upper hole to maximize a cooling rail slots free of debris that might cause bolts to bind in the airflow under the modules.This may enhance perfor- slots. mance in hotter climates. Consider the weight of a fully assembled panel.UniRac recom- Adjust the position of the panel as needed to fit the instal- mends safety lines whenever lifting one to a roof. lation area.Slide the remaining L-feet bolts onto the other Align the panel with the previously installed L-feet.Slide'/e- rail,attach L-feet,and finger tighten with flange nuts.Align inch L-foot mounting bolts onto the rail and align them with L-feet with mounting holes previously drilled into roof.Install the L-feet mounting holes.Attach the panel to the L-feet and lag bolts into remaining L-feet as described in"Laying out and finger tighten the flange nuts. installing L-feet"above. Rails may be attached to either of two mounting holes in the Torque all footing flange nuts to 30 foot-pounds.Verify that all footings(Fig.23). lag bolts are securely fastened. Clip slots . . ' Mounting slots Flange Footing \ nut boll slot Figure 23.Leg-to-rail attachment PaSc 19 UN®I"C" Installation Manual 214 SolarMount Code-Compliant Planning and Assembly 10 year limited Product Warranty, 5 year limited Finish Warranty UniRac,Inc.,warrants to the original purchaser the practices specified by AAMA 609&610-02 If within the specified Warranty periods the ("Purchaser')of product(s)that it manufactures —"Gleaning and Maintenance for Architecturally Product shall be reasonably proven to be ("Product")at the original installation site that Finished Aluminum"(www.aamanetorg)are not defective,then UniRac shall repair or replace the Product shall be free from defects in material followed by Purchaser.This Warranty does not the defective Product,or any part thereof, and workmanship for a period often(10)years, cover damage to the Product that occurs during in UniRac's sole discretion.Such repair or except for the anodized finish,which finish its shipment,storage,or installation. replacement shall completely satisfy and shall be free from visible peeling,or cracking or This Warranty shall beVOID if installation of discharge all of UniRac's liability with respect to chalking under normal atmospheric conditions the Product is not performed in accordance this limited Warranty.Under no circumstances fora period of five 5 ears,from the earlier shall UniRac be liable for special,indirect or P ( )Y with UniRac's written installation instructions, of I)the date the installation of the Product is or if the Product has been modified,repaired, consequential damages arising out of or related completed,or 2)30 days after the purchase of or reworked in a manner not previously to use by Purchaser of the Product. the Product by the original Purchaser("Finish authorized by UniRac IN WRITING,or if the Manufacturers of related items,such as PV Warranty"). Product is installed in an environment for which modules and flashings,may provide written The Finish Warranty does not apply to any it was not designed.UniRac shall not be liable warranties of their own.UniRac's limited foreign residue deposited on the finish.All for consequential,contingent or incidental Warranty covers only its Product,and not any installations in corrosive atmospheric conditions damages arising out of the use of the Product by related items. are excluded.The Finish Warranty isVOID if Purchaser under any circumstances. THE U p a v� STANDARD 69 . AC NV UniRac,Inc. 1411 Broadway NE 505.242.6411 20 www.unirac.com Albuquerque NM 87102-1545 USA 505.242.6412 Fax ,q 1 Revisions: �11 ►0'JE� AS NOTED DATE: R.P.�? nc�o.-.. FEE: }:NOTIFY BUILDING BUILDING i'r,RTMENT AT — — — — — — — — — — — — _ — — — — — — — 765-1802 8 Ali TO 4 PM FOR TIME FOLLOWING INSPECTIONS: 1. FOUNDATION'- T'A'0 REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 1 1 I I 1 3. INSULATION 4. FINAL - CC`!�l-�-?'JCTION MUST — — — — — — — — — — — — — — — — — — — — BE COMPLL"_ i CR C.G. I ALL CONSTRUCTION SHALL MEET THE REQUIRENFNTS OF THE CODES OF NEW O a II I 9 Z 1L CTYP , ) I 9 Z 1L C T Y P , ) I ��z 1L C T Y P� ) YORK STHTE, NOT RESPOfd'�SIRLE FOR o a N 3 0 DESIGN OR CONSTRUCTION ERRORS. 3 3 a o w o V W> z? O o- z wL)oz 1 1 COMPLY WITH ALL CODES OF < �, 0V woaw — — — — — — — — — — NEW YORK STA c & TOWN C )DE _ _ �� 3`) — — — — AS REQUIRED AP:�,� �, ^ `` 1 1 may*{ 000J-o v (/ Lj � azo�v'> C in a zrg- 0wm o � ' in>ui :��% —I - - - - - - - - - - - - - - - - RY.S.DEC 0 CsklPANCY OR L1vE i UNLAWFUL L 1 i - - - - - - - - - - I T, WI =-i .BUT CERTIFICATE J z Q) o w ti 1 UNIRAC SOLAR MOUNT OF OCCUPANCY RAILS 1 I z 0 Q� N BOLTED TO " Z " PULINS CTYP , ) Q 0- J - - - - - - - - - - � ALL CONSTRUCTION SHALL NN OO V-EET THE REQUIREMENTS OF THE Q Q Cfl DE ;OS OF NE4V YOhK STATE, O co 1 2 3 4 51 6 7 8 9 I co z 1 2 13 14 I 151 16 17 18 191 20 21 22 23 124 21i 26 27 28 1 ' L "t2" GEND- U) z I 1 - - - - - - - 5- 6- - --- 41 421 2 -3 a - �®_ o 43 44 45 46 47 48 49 50 PROPOSED SOLAR PANEL m _ _ _ _ — - - — — — — -- - - - - - - INSTALLATION - - z o tri . - - - - - - - - - - - - - - Cl� Q -1 I POSSIBLE w FUTURE SOLAR Om � _ 1 J J i L PANEL INSTALLATION Q O (3) >- - -IL - - - - - - - - - - - cn CN— — — — — — — — — — — — — — � p 0 U � U N O AA NIL r L #% ROOF r m M. 0 n .. r o LLJ 3 a J Lo o T- ° � 1 r C) THIS IS TO CERTIFY THAT WE HAVE CHECKED ALL ALUMINIUM MEMBERS TO BE 6105 T5 NOTE : THE ROOF STRUCTURE FOR WIND , SNOW, SEALd:�r� �, ALLOY. 50 — GtL SOLAR PANELS : GEPVp - 200 UNBALANCED SNOW, LIVE AMD DEAD LOADS 200 Watts BASED ON ASCE 7 - 98 AND FOR � ALL BOLTS TO BE SAE GRADE 5 STAINLES CONFORMANCE WITH THE NYS BUILDING CODE. � " STEEL OR BETTER WITH STAINLESS STEEL_ �_?n g th = 58 . 5 lJ f u ` VIdth = 38 . 6 °A 4,GO WASHERS, PLATES AND NUTS THIS ROOF STRUCTURE IS ADEQUATE TO Thickness = 1 . 4 SUPPORT THE PROPOSED LOADS Project N/ O 0 29 1 / a. a Z �Sl 3 p