Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
33056-Z
FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-32953 Date: 03/31/08 THIS CERTIFIES that the building NEW DWELLING Location of Property: 175 FIRST ST LAUREL (HOUSE NO.) (STREET) (HAMLET) County Tax Map No. 473889 Section 126 Block 10 Lot 9.5 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated MAY 14, 2007 pursuant to which Building Permit No. 33056-Z dated MAY 21, 2007 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is SINGLE FAMILY DWELLING WITH ATTACHED TWO CAR GARAGE & COVERED FRONT ENTRY AS APPLIED FOR. The certificate is issued to VINCENT & MAUREEN PAPA (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL R10-05-0020 03/10/08 ELECTRICAL CERTIFICATE NO. 8111 02/20/08 PLUMBERS CERTIFICATION DATED 02/27/08 MATTITUCK PLUMB.& HEATING s A thorized Signature Rev. 1/81 �lr__J u_ -`._, FormNo.6 TOWN OF SOUTHOLD C 2-8 2K,_ ,, ; �; ' BUILDING DEPARTMENT j 6' TOWN HALL 765-1802 �:..: APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$25.00, Additions to dwelling$25.00, Alterations to dwelling$25.00, Swimming pool$25.00, Accessory building$25.00,Additions to accessory building$25.00,Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial $15.00 Date. 3/ c �/ o I. New Construction: X Old or Pre-existing Building: (check one) Location of Property: I-� 2: � S T e, House No. Street H mlet NOwner or Owners of Property: �� If�C,ey� " } {Aynf e.r,-� Suffolk County Tax Map No 1000, Section a la _Block 0 0 Lot 023 QO S� Subdivision Filed Map. ot: Permit No. 3 0 �Date of Permit. -D A licant: FRCr� 1 A- Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: /` (check one) Fee Submitted: $ IS 1 0(� Applicant Signature co Nassau Suffolk Electrical Inspections,Inc. P.O.Box 549,Aquebogue,New York♦ 11931 Tel: 631-591-3097 Fax: 631-591-3098 Application: 8111 Date: 2/20/08 Issued to: Papa Address: 75 First St Introduced By: M&B Electric Village: Laurel License#: 38879-ME Residential 0 Commercial The following was examined and approved up to the above date and found to be in compliance with the NEC: Attic 0 I" Floor ❑x 2"d Floor ❑x 3rd Floor Garage Conversion Basement ❑x Hot Tub Addition Detached Garage Pool Switches Receptacle Fixtures G.F.I. Microwave Smoke Detectors 53 5T 62 8- 1 Fans Dishwasher Washer/Amps Dryer/Amps Oven Range/Amps Carbon Monoxide 3-Ex Bath I 1 1 1-Elec Wall 2 Oven Furnace Oil Gas Heat Zones Whirlpool Bell Transformers 1 Yes 2 1 Final Insp. Meter Amps Phase Motors 2/20/08 1 200A UG 1 Other Equipment: I-Gas Cooktop D a4.e. Q5.#A S ec l2.- 3. This certificate must not be altered in any manner - �g�FFO('�coG O N = Town Hall, 53095-Main.Road,. O � � Fax (631) 765-9502 P_O:•Box 1 179 �O� �aO� Telephone (631) 765-1 SU2- Sou!ho!c. New York 11971.0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATION Date: O Sr Building Permit No. (Please print) '. . rVI Plumber: (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. (Plumbers Signature) Al tl I Sworn to b fore me this da\ o 20 O0 DENISE KING Notary Public, State of New York Registration #01 K16041757 Qualified in Suffolk County 74 My Commission Expires May 15,2 QLO Notary Public, !� County FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 33056 Z Date MAY 21, 2007 Permission is hereby granted to: VINCENT & MAUREEN PAPA 22 SOUTH KENNEDY DRIVE CENTEREACH,NY 11720 for CONSTRUCTION OF A NEW SINGLE FAMILY DWELLING WITH ATTACHED TWO CAR GARAGE & COVERED FRONT ENTRY AS APPLIED FOR at premises located at 175 FIRST ST LAUREL County Tax Map No. 473889 Section 126 Block 0010 Lot No. 009 . 005 pursuant to application dated MAY 14 , 2007 and approved by the Building Inspector to expire on NOVEMBER 21, 2008 . Fee $ 1, 999 . 20 Authorized Signature ORIGINAL Rev. 5/8/02 OF SO�ryo�o �o old o Mv,Oe TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING P<FINAL /*— of [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: off, DATE INSPECTOR OG SO330 576 7- pTyOlo 0 • ao UNTI, TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [KFINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: 1 �- DATE 3 j ° INSPECTOR SOUryo`o 3 ®�� Z_ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND XINSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION RE ARKS: VA)� t ca A DATE . ®��� _® � INSPECTOR P OF SOUlyOlo l 05� UMY,� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST kROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION XjRA STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS! �J ~ DATE ?ten- 07 INSPECTOR • } pF SOUIyO�o 33o56 Z- # '� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSP. ECTION [FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: i y DATE 7��~ INSPECTOR OF SObryolo TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION [ FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: r 1 p� DATE / , �� 7 INSPECTOR so couIff`i,� TOWN OF SOUTHOLD BUILDING DEPT. 765-1602 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. KFOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: Zf" / ! r V 7 DATE INSPECTOR JAMES J. DEERKOSKI, P.E. 260 Deer Drive Mattituck, N.Y. 11952 DG_1 310 20Ji (631) 298-7116 [JLD 1 7 TOW�tIQF S ",'TNOI- Date: October 29, 2007 To: Town of Southold Re: Insulation Inspection Papa 75 First St Larel, NY Permit# 33056 To Whom It May Concern: An Insulation Inspection was preformed at the above mentioned property; all insulation was installed as per amended Insulation Plan and meets all State and local Building Codes. Any questions please feel free to call. e � 'NEW EER/r� 5 Sin erely � 4 COO S \.." James J. ee koski P.E. `' 1 F ' FIELD INSPECTION REPORT DATE I COMMENTS FOUNDATION(1ST) FOUNDATION(2ND) t� z eat ROUGH FRAMING& a ' PLUMBING -------- 'l --=3° ' - c x INSULATION PER N.Y. -- H STATE ENERGY CODE re FINALL v l .�' ADDITIONAL COMMENTS c d � 'D5 lss� �l s a� � Sri A- Q n m 0 PC CgAl_ At � H O z d Q H LR x H TOWN OF SOUTHOLD _ BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL 4 Board of Health SOUTHOLD,NY 11971 14 2007 :_;i 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Surve www.northfork.net/Southold/ - PERMIT NO: 3051 Check Septic Form N.Y.S.D.E.C. Trustees Examined a� ,2007 Contact: Approved 5 - 20Z7— Mail to: Disapproved a/c Phone: Expiration ,20 015 uilding Inspector APPLICATION FOR BUILDING PERMIT Date �5//0 , 20 0 INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing, the extension of the permit for an addition six months.Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws, ordinances,building code,housing code,and regulations, and to admit authorized inspectors on premises and in building for necessary inspections: (Signature of applic0i or name,if a corporation) (Mailing address of applicant) '�f-4j,72.,) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises V (N Ce A M A 0 IL6-6;-Al ll. /4 (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of�corporate officer) Builders License No. Plumbers License No. r, Electricians License No. l� �- Other Trade's License No. 1. Location of land on which I oposed work will be done: Z-4-vot&Z A House Number Street Hamlet County Tax Man No. 1000 Section /00'0 Block Z Lot ` Subdivision CU 2 U c� r'(J 7-'/4 i L L Filed Map No. Vto Lot (Name) 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Vs E A-7-1 o A] _t3 bp�nog,� hj= b. Intended use and occupancys 3. Nature of work(check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work (Description) 4. Estimated Cost 's 0 0 p o o Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars ?, 6. If business, commercial or mixed occupancy, specify nature and extent,of each type of use. 7. Dimensions of existing structures, if any: Front 7/Z Rear Depth qy 6 Height Number of Stories slte 6 Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front -7 L J Rear `1 2. - J Depth Y 7 Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase ( Name of Former Owner Jgp-Q/C I< O U4 12 4i u 4- 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO Will excess fill be removed from premises? YES NO 14. Names of Owner of premises �111✓CZ'A/7_' 11VAAddress- Phone No.6 31• � �; Z-7 2 9!Z Name of ArchitectGL Lk t,� k&t- -'--101 G-6 G ft Address Phone No (9 30 - -7 3 7 V 7 k-k 7 Name of Contractor�;�/1&�P and/y ,7;2 Address Phone No. —,50 3 z 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTY OF ) being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)He is the (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this --�day of Ay 20 0;7 Notary Public Signature of plicant Phyllis Fritz Notary Public state of New Yo NO.01FR�aliffed in 60ti0293 ty Comm s ion Expir�sJune 1e,fez Erosion, Sedimentation and Storm-water Run-off Control Plan ASSESSMENT FORM Yes. No. EXEMPTIONS:. A. Does.this project meet the.minimum standards for classification as.an Agricultural Project. Note: If you.answered.Yes.to any.of the.above,a.Storm-water,Grading,Drainage.&.Erosion.Control.Plan is.not required. ------------------------------------------------------- ACTIONS.REQUIRING THE.SUBMISSION OF A STORM-WATER, GRADING,DRAINAGE &EROSION. CONTROL.PLAN.CERTIFIED.BY A DESIGN.PROFESSIONAL.IN.THE.STATE.OF NEW YORK.. Item Number:. (A Check Mark (J).for each question is.required for complete.application). Yes. No. 1. Will this.project retain all Storm-Water Run-off generated on Site? (This:will include.all run-off created by site.clearing and/or construction activities.as.well as.all Site.Improvements.and the.permanent creation of impervious.surfaces.) C 2.. Will this.project.require any land filling,grading or excavation where.there.is.a change to the natural existing grade involving more than 200 cubic yards.of material within any.parcel? X K Will this.application require.land disturbing activities.encompassing an area. of five.thousand(5,000)square feet of ground surface or more? ❑ X 4. Is.there.a Natural Water course.running through the.site or is.this.project within One.hundred(100)feet of wetlands or a beach? 5. Will there be site.preparation on slopes which exceed.fifteen(15),feet of vertical rise.to. One.hundred(100)feet of horizontal distance? X 6.. Will driveways,parking areas or other impervious..surfaces.direct Storm-Water.Run-off. into.and/or in the.direction of a Town Right-of-Way? X 7. Will this application 'require the placement of material,removal of vegetation and/or the. construction of any,item within the Town Right-of-Way or road shoulder area? (This item.does.not include.the.installation.of driveway aprons.) 8. Will there.be.site preparation within the one hundred(100)year floodplain of any watercourse? Note:. If.any answer to.questions one through.eight is.answered,with,a check mark in the.Box,.a Storm-water,Grading, Drainage.&Erosion.Control.Plan is,required.and.must be.submitted for review prior to.issuance.of any building.permit. ------------------------------------------------------------------- STATE OF NEW YORK, COUNTYOF................................................ ss That I, ... .N l /I-P/I ...being duly sworn,deposes and says that he/she is the applicant for Permit, (Name of individual signing Document) n And that He/She is the ..............�.W)v t% ................................................................................................................................................ (Owner,Contractor,Agent,Corporate Officer,etc.) Owner and/or representative of the Owner or Owner's,and is duly authorized to perform or have performed,the said work and to make and file this application;that all statements contained in this application are true to the best of his knowledge and belier; and that the work sill be performed in the manner set forth in the application filed herewith. Sworn to before me this; ........ ...........................day of.....M.17.1.....................20.®.7 - Notary Public: ......... .. '........ ......��.................. ................ Phyllis Frltz (Signature of Appli t) wry Public State of New York No.01 FA60602g9 r�ty Commles oin Explreua June 1e,20� OLUECKERU AND MESER 20 Peachtree Court, Holbrook, New York, 11741 631 - 737 - 4747 562 Lake Caroline Drive, Ruther Glen, Virginia, 22546 804 - 448 - 8232 MAY 25 2,r,I May 16, 2007 Project#27007 Re: Papa Residence Town of Southold Building Department 53095 Route 25 P.O. Box 1179 Southold,N.Y. 11971 Dear Building Official, Please be advised that(2) 8'- 0" dia. x 7'- 0" deep roof storm drain pools will be provided with 4"PVC SDR 35 piping to gutters and leaders. Locations to be in rear, northwest corner and front, southwest corner of property. If you should have any questions,please feel free to contact this office. Ver.syot�ZcS, i i p`lrl q: or iebe , GEW/pf -r..,-. Cc: Mr. Vinny Papa ITTNATIONAL COUNCIL OF ARCHITECTURAL REGISTRATION BOARDS OLUECKERU AND MEBER In ROW 0TECTSg LLG. 20 Peachtree Court, Holb ;;;;, New York, 11741 631 - 737 - 4747 562 Lake Caroline Drive;R #her;,, .len, Virginia, 22546 804 - 448 - 8232 1: May 24, 2007 Project 4 27007 Re: Papa Residence Town of Southold Building Department 53095 Route 25 P.O. Box 1179 Southold,N.Y. 11971 Attention: Ms. Pat Conklin Dear Ms. Conklin, As per your conversation with my office, we will reduce the overhang at the kitchen bay door by 4"to 1' —4"which will eliminate the rear yard encroachment. We hope this will satisfy the requested revisions and look forward to your approval. Thank you for your assistance in this matter. Rer, tful'ly.sftbi ' ed, 4e N. tBN ON GEW/pf Cc: Vinny Papa NATIONAL COUNCIL OF ARCHITECTURAL REGISTRATION BOARDS REScheck Software Version 4.0.1 Compliance Certificate Project Title: PAPA RESIDENCE Report Date:04/04/07 Data filename:Z:\shared\John\sodano-latest\2007\27007-papa\PAPA2.rck, Energy Code: New York State Energy Conservation Construction Code Location: Suffolk County,New York Construction Type: Detached 1 or 2 Family Heating Type: Non-Electric Glazing Area Percentage: 13% Heating Degree Days: 5750 Construction Site: Owner/Agent: Designer/Contractor: 75 FIRST STREET VINCENT PAPA GEORGE E.WIEBER LAUREL,NY 11948 75 FIRST STREET GLUECKERT and WIEBER, LAUREL,NY 11948 ARCHITECTS. 20 PEACHTREE CT,SUITE 101 HOLBROOK,NY 11741 731-737-4747 Compliance: . ..• Gross Cavity Cont. Glazing UA Assembly Area or R-Value R-Value or D.. Perimeter U-Factor Ceiling 1:Flat Ceiling or Scissor Truss: 2356 38.0 0.0 71 Ceiling 2:Cathedral Ceiling(no attic): 204 38.0 0.0 6 Wall 1:Wood Frame,16"o.c.: 3315 21.0 0.0 161 Window 1:Wood Frame:Double Pane: 341 0.330 113 Door 1:Solid: 63 0.330 21 Door 2:Glass: 84 0.330 28 Floor 1:All-Wood Joist/Truss:Over Unconditioned Space: 1370 21.0 0.0 60 Floor 2:All-Wood Joist/Truss:Over Outside Air: 1190 21.0 0.0 52 The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted With this permit application.The proposed systems have been designed to meet the-New York State Energy Conservation Construction Code requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code. Name-Title Signature Date IERED A,?C V.UGENF O T i� .� I. rn K ST 1 05 DT I0 NEW PAPA RESIDENCE Page 1 of 4 REScheck Software Version 4.0.1 Inspection Checklist Date:04/04/07 " Ceilings:. . ❑ Ceiling 1:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation Comments: ❑ Ceiling 2:,Cathedral Ceiling(no attic),R-38.0 cavity insulation Comments: Above-Grade Walls: .[].Wall 1:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: Windows: . ❑ Window 1.:Wood Frame:Double Pane,U-factor:0.330 For windows without"labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors:. ❑ Door 1:Solid,U-factor:0.330 Comments:. ❑ Door 2:Glass,U-factor:0.'330 Comments: Floors: ❑ Floor 1:_AII-Wood-Joist/Truss:Over,Unconditioned Space,R-21.0 cavity insulation Comments: . . .. ❑ Floor 2:All-Wood Joist/Truss:Over Outside Air,R21.0 cavity insulation . Comments: Air Leakage: ❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed. ❑ Recessed lights are 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,fixtures are installed with a 3"clearance from insulation. . Vapor Retarder: ❑ Installed on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification:' ❑. Materials and equipment are installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment are identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating'equipment have been provided. ❑. . Insulation R-values and glazing U-factors.are clearly marked.on the building plans:or specifications. 0 Insulation is installed according to manufacturer's:instructions,in substantial contact with the surface being insulated,and in a manner that achieves the rated R-value without compressing'the insulation. Duct Insulation: ❑. Supply ducts in unconditioned attics or outside the building are insulated to.R-8.; PAPA RESIDENCE Page 2 of 4 Return ducts in unconditioned attics or outside the building are insulated to R-4. Supply ducts in unconditioned spaces are insulated to R-8. ❑ Return ducts in unconditioned spaces(except basements)are insulated to R-2.Insulation is not required on return ducts in basements. Duct Construction: 0 All joints,seams,and connections are securely fastened with welds,gaskets,mastics(adhesives),mastic-plus-embedded-fabric, or tapes.Tapes and mastics are rated UL 181A or UL 181 B. Exceptions: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). ❑ The HVAC system provides a means for balancing air and water systems: Temperature Controls: Ll Each dwelling unit has at least one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: Separate electric meters exist for each dwelling unit. Fireplaces: Fireplaces are installed with tight fitting non-combustible fireplace doors. Fireplaces have a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: 0 Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. Circulating hot water pipes are insulated to the levels in Table 1. Circulating Hot Water Systems: ❑ Circulating hot water pipes are insulated to the levels in Table 1. Swimming Pools: ❑ All heated swimming pools have an on/off heater switch and a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps have a time clock. Heating and Cooling Piping Insulation: 0 HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2. PAPA RESIDENCE Page 3 of 4 Table 9:Minimum Insulation Thickness for Circulating Hot.Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Up to V Up to 1.25" 1.5"to 2.0" Over 2" Temperature(°F) 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2. Minimum Insulation Thickness for HVAC Pipes Insulation Thickness,in Inches by Pipe Sizes Piping System Types Fluid Temp.Range(°F) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Heating Systems. Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) PAPA RESIDENCE Page 4 of 4 Permit# Permit Date REScheck Software Version 3.7 Release 1 b Compliance Certificate Project Title: 75 First St. Report Date:10/29/07 Energy Code: 2000 IECC Location: Peconic,New York Construction Type: Single Family Glazing Area Percentage: 13% Heating Degree Days: 5572 Construction Site: Owner/Agent: Designer/Contractor: VINCENT PAPA 75 FIRST ST LAREL,NY Ceiling 1:Flat Ceiling or Scissor Truss: 2356 30.0 0.0 82 Ceiling 2:Cathedral Ceiling(no attic): 204 30.0 0.0 7 Wall 1:Wood Frame,16"o.c.: 3315 19.0 0.0 170 Window 1:Wood Frame:Double Pane with Low-E: 341 0.330 113 Door 1:Solid: 63 0.330 21 Door 2:Glass: 84 0.330 28 Floor 1:All-Wood JoistlTruss:Over Unconditioned Space: 1370 19.0 0.0 64 Floor 2:All-Wood J oist/Truss:Over Outside Air: 1190 19.0 0.0 56 Compliance Statement:Statement of Compliance:The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2000 IECC requirements in REScheck Version 3.7 Release 1 b and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. �Rma.s /a 2. Builder/Designer Company Name Date OFE 75 First St. Page 1 of 4 REScheck Software Version 3.7 Release 1 b Inspection Checklist Date: 10/29/07 Ceilings: ❑ Ceiling 1:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation Comments: ❑ Ceiling 2:Cathedral Ceiling(no attic),R-30.0 cavity insulation Comments: Above-Grade Walls: ❑ Wall 1:Wood Frame,16"o.c.,R-19.0 cavity insulation Comments: Windows: ❑ Window 1:Wood Frame:Double Pane with Low-E,U-factor:0.330 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door 1:Solid,U-factor:0.330 Comments: ❑ Door 2:Glass,U-factor:0.330 Comments: Floors: ❑ Floor 1:All-Wood JolstfTruss:Over Unconditioned Space,R-19.0 cavity insulation Comments: ❑ Floor 2:All-Wood JoisttTruss:Over Outside Air,R-19.0 cavity insulation Comments: Air Leakage: ❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. ❑ Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: ❑ Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: ❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment must be identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. ❑ Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: ❑ Ducts in unconditioned spaces must be insulated to R-5.Ducts outside the building must be insulated to R-6.5. Duct Construction: 75 First St. Page 2 of 4 v ❑ All joints,seams,and connections must be securely fastened with welds,gaskets,mastics(adhesives), mastic-plus-embedded-fabric,or tapes.Tapes and mastics must be rated UL 181A or UL 181 B. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). ❑ The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ❑ Thermostats are required for each separate HVAC system.A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: ❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: ❑ Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: ❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps require a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. 75 First St. Page 3 of 4 Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Temperature(°F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range ff) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) 75 First St. Page 4 of 4 REScheck Software Version 4.0.1 Compliance Certificate Project Title: PAPA RESIDENCE Report Date:04/04/07 Data.filename:Z:\shared\John\sodano-latest\2007\27007-papa\PAPA2.rck Energy Code: New York State Energy Conservation Construction Code Location: Suffolk County, New York Construction Type: Detached 1 or 2 Family Heating Type: Non-Electric Glazing Area Percentage: 13% Heating Degree Days: 5750 Construction Site: Owner/Agent: Designer/Contractor: 75 FIRST STREET VINCENT PAPA GEORGE E.WIEBER LAUREL,NY 11948 75 FIRST STREET GLUECKERT and WIEBER, LAUREL,NY 11948 ARCHITECTS 20 PEACHTREE CT,SUITE 101 HOLBROOK,NY 11741 731-737-4747 Compliance: . Gross Cavity Cont. Glazing ILIA Assembly Area or R-Value R-Value or D.. Perimeter U-Factor Ceiling 1:Flat Ceiling or Scissor Truss: 2356 38.0 0.0 71 Ceiling 2:Cathedral Ceiling(no attic): 204 38.0 0.0 6 Wall 1:Wood Frame,16"o.c.: 3315 21.0 0.0 161 Window 1:Wood Frame:Double Pane: 341 0.330 113 Door 1:Solid: 63 0.330 21 Door 2:Glass: 84 0.330 28 Floor 1:All-Wood Joist/Truss:Over Unconditioned Space: 1370 21.0 0.0 60 Floor 2:All-Wood Joist/Truss:Over Outside Air: 1190 21.0 0.0 52 The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code. Name-Title Signature Date 5-Iv RFD A/?Cy' 0SUGEn,F TF�� M i- S>, -14 0 "9TF OF PAPA RESIDENCE Page 1 of 4 REScheck Software Version 4.0.1 Inspection .Checklist Date:04/04/07 Ceilings: ❑ Ceiling 1:Flat Ceiling or Scissor Truss,R=38.0 cavity.insulation Comments: ❑-Ceiling 2:Cathedral Ceiling(no attic),.R-38.0 cavity insulation Comments: Above-Grade Walls: 0.Wall 1:Wood Frame,16"o.c.,.R-21.0 cavity insulation Comments: Windows: ❑ Window 1:Wood Frame:Double Pane,U-factor:0.330 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors ❑ Door 1::Solid,U-factor:0.330 Comments: ❑ Door 2:Glass,U-factor:0.330 Comments: Floors: ❑.Floor.:.All-Wood,Joist(Truss:Over.Unconditioned Space,R-21;0 cavity insulation Comments: ❑ Floor.2:All-Wood Joist/Truss:Over Outside Air,R-21.0 cavity insulation Comments: Air.Leakage: ❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed. ❑ Recessed lights are 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,fixtures are installed with a 3"clearance from insulation. Vapor Retarder: ❑ Installed on the warm-in-winter.side of all non-vented framed ceilings,walls,and floors. - Materials Identification: ❑_ Materials and equipment are installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment are identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. ❑ Insulation R-values and glazing U-factors are clearly marked on the building plans or specifications. ❑- Insulation is installed according to manufacturer's instructions,in substantial contact with the surface being insulated,and in a manner that achieves the rated R-value without compressing the insulation. Duct Insulation: ❑ Supply ducts in unconditioned attics or outside the building are insulated to:R-8. PAPA RESIDENCE Page 2 of 4 I] Return ducts in unconditioned attics or outside the building are insulated to R4. Supply ducts in unconditioned spaces are insulated to R-8. Return ducts in unconditioned spaces(except basements)are insulated to R-2.Insulation is not required on return ducts in basements. Duct Construction: L1. All joints,seams,and connections are securely fastened with welds,gaskets,mastics(adhesives),mastic-plus-embedded-fabric, or tapes.Tapes and mastics are rated UL 181A or UL 181 B. Exceptions: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). 0 The HVAC system provides a means for balancing air and water systems. Temperature Controls: Ll Each dwelling unit has at least one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: Separate electric meters exist for each dwelling unit. Fireplaces: Fireplaces are installed with tight fitting non-combustible fireplace doors. O Fireplaces have a source of combustion air,as.required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Circulating hot water pipes are insulated to the levels in Table 1. Circulating Hot Water Systems- 0 Circulating hot water pipes are insulated to the levels in Table 1. Swimming Pools: All heated swimming pools have an on/off heater switch and a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps have a time clock. Heating and Cooling Piping Insulation: ❑. HVAC piping conveying fluids.above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2. PAPA RESIDENCE Page 3 of 4 Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Temperature(°F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 .1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 . Table 2:Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range ff) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) PAPA RESIDENCE Page 4 of 4 "N�o£ SURVEY OF \ .; LOTS 99 & 100 �A r SUBDIVISION MAP OF PROPERTY OF GEORGE I. TUTHILL & OTHERS SECTION ONE \ FILE No. 861 FILED JANUARY 15, 1929 SUFFOLK Douvmy DERARTMENT.®F HEALTH SERVICES SITUATED AT \ O�E�LING PERMIT FOR APPROVAL;C��,CON!Ti SUCTION FOR A M ATT I T U C K \ fqo SINOLEFAmwMESiDENCEAND TOWN OF SOUTHOLD 4 SUFFOLK COUNTY, NEW YORK ��or �5p op_ \ -�S.C. TAX No. 1000-126-10-9.3� p rrr� N\ 1000126-10-9.4 11 �gLv y `DATE ) CI? �". .s ��. 0-05 40,�D SCALE 1"=40' 1� m a„\ JUNE 30, 1995 SURVEY LOT 100 & HEALTH DEPT. DATA °'` , o APPROVED 4 DECEMBER 27, 2002 REV02 ADDED ISED ED BUILDING ENVELOPE 10p0.126_10T 99 _9 .� Vn ^ '. AUGUST 25, 2006 ADDED PROPOSED ADDITION TOTAL-I&IMUM BEDROOMS NOVEMBER 6, 2006 REVISED AS PER S.C.D.H.S. INCOMPLETE NOTICE JANUARY 11, 2007 REVISED PROPOSED_SEPTIC SYSTEM TO A 5-6 BEDROOM HOUSE 9 N � �e, `� "' � EXPIRES THREE YEARS FROM DATE Ot=APPROVAL T 99 \ spP - s tr AREA = 20,086.11 Sq. ft. �� � v: A6 j , �•�,�•�" � � TEST HOLE DATA LL. 15.1• _°• CERTIFIED TO: 1 l\NO x- _ d" 1n LrI \" • �' °ARn eRowN w y Low VINCENT PAPA 2To ��w. i . _@ A ando6ent of existing sanitary system must be i 1 / Bm»N LOMr SV D >r 7 , c a conformance t1th department requirement Su tit x �- •� i SO �� �' -`- -_ _ -� campleted\font+dN1�►Nl- as proof 1. ELEVATIONS SHOWN THUS: ARE REFERENCED TO AN N.G.V.D. 1929 DATUM. i e 2. TEST HOLE DUG BY Mc00NALD GEOSCIENCE ON JUNE 23. 1995. 6y.T5' 0,1Diar Nai "• •A'` 3. ZONING USE DISTRICT: R-40 J. ,000'TZ 4 4. MINIMUM SEPTIC TANK CAPACITIES FOR A 5-6 BEDROOM HOUSE IS 1,500 GALLONS. O mod, N•`� i� tlx�� $q`, TO coL TNLAND 5. MINIMUM LEACHING SYSTEM FOR A 5-6 BEDROOM HOUSE IS 400 sq ft SIDEWALL AREA. 2 POOLS: 8• DIA. X 6' DEEP PROPOSED FUTURE 50% EXPANSION POOL [L-0.7• _1�.. �PROPOSED B• DIA. X 8' DEEP LEACHING POOL WATEF1 IN PALL WO- PROPOSED 1.500 GALLON SEPTIC TANK 1 r £ nNE 70 CWRSE SAND 6 THE LOCATION OBSERVATIONS OF WELLS AND CESSPOOLS AND/OR DATA OBTAINED FROM WN OTHERS. THERSREON ARE FROM FIELD wo �% /■1 /0Y Q'+� 7 BACK- FILLED WITH SEPTIC SYSTEM SA SAND, INUCTURES SHALL ACCORDANCE WITTH S.C.DEH.SCLEAN AND ACK- STANDARDS. a1N LO 1 00 \ 4\\\ ti � 01 e yw O PRE2E_&FD ACCORDANCE WITH THE MINIMUM O SrANDARTJ-OR TITLE SURVEYS AS ESTABLISHED LEES..�.[LND APPROVED AND ADOPTED • �� �'rPRE='AS' •NATION)BV-TNEW YORK STATE LAND y 4. Ir lo`\�oPGOpG\\ �S� �(`,r N.Y.S. Lic. No. 49668 >>pp 1, UNAUTHORIZED4LTERATION OP. ADDITION 11bau TO TH15 SURVEY 15 A VIOLATION OF SECTION 721019LA OF THE NEW PORK STATE �OC ph A. Ingegno F•Q. � 2 I EDUCATION LAW J L OR 5. COPTHEIES OF THIS SURVEY MAP NOT BEARING EMBOSSED SEAL SOHALL INKED BEECONSIDERED Land Surveyor TO CERTIFICATIONS A VALID TRUE COPY I CERTITI FICATIONS INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED. AND ON HIS BEHALF TO THE ,v TITLE COMPANY, GOVERNMENTAL AGENCY AND Title Surveys — Subdivisions — Site Plans — Construction Layout �J LENDING INSTITUTION LISTED HEREON. AND TO THE ASSIGNEES OF THE LENDING INSR- TUIION CERTIFICATIONS ARE NOT TRANSFERABLE PHONE (631)727-2090 FOX (631)727-1727 W� THE EXISTENCE OF RIGHT OF WAYS OFFICES LOCATED AT MAILING ADDRESS O AND EASEMENTS OF RECORD, IF 322 ROANOKE AVENUE P.O. Box 1931 ANY,, NOT SHOWN ARE NOT GUARANTEED. RIVERHEAD. New York 11901 Riverhead, New York 11901-0965 SURVEY OF LOTS 99 & 100 SUBDIVISION MAP OF PROPERTY OF GEORGE I. TUTHILL & OTHERS SECTION ONE FILE No. 861 FILED JANUARY 15, 1929 SITUATED AT MATTITUCK TOWN OF SOUTHOLD w SUFFOLK COUNTY, NEW YORK fP S.C. TAX No. 1000-126-10-9.3 1I 3 ��GO �•� 1000-126-10-9.4 SCALE 1"=40' JUNE 30, 1995 SURVEY LOT 100 & HEALTH DEPT. DATA y DECEMBER 12, 2002 ADDED LOT 99 fad Lr O- o O: DECEMBER 27, 2002 REVISED BUILDING ENVELOPE oo. AUGUST 25, 2006 ADDED PROPOSED ADDITION NOVEMBER 6, 2006 REVISED AS PER S.C.D.H.S. INCOMPLETE NOTICE JANUARY 11, 2007 REVISED PROPOSED SEPTIC SYSTEM TO A 5-6 BEDROOM HOUSE JUNE 11, 2007 STAKE FOUNDATION JULY 10, 2007 FOUNDATION LOCATION 2 ; AREA = 20,086.11 sq. ft. to / 0.461 ae. 'p CERTIFIED T0: o, 6-10'9 3 •a. �� 9p� VINCENT PAPA 0a�12 O o, O O glOL N 10 �E 0-94 9Oy� •SA, i1• `b°••~52 6L g WPU'°i�9 ;o0 126-1 Z� No. 4.6 •-� ?,; A N O 0 G g0 'o. O �°55• i TO �•' J5-0— Of 1. P PCC CE WITH THE MINIMUM � t17,q/ RVEYS AS ESTABLISHED PTED N OVED YORKN STATE LAND .O JB.4 fQL CO a 50467O � F 04AND 5 N.Y.S. Lic. No. 50467 ��R• e' C) UNAUTHORIZED ALTERATION OR ADDITIONAo� TO THIS SURVEY ^s ..... SECTION 7209 OF NEW YORK STATE Q�°� 41 EDUCATION LAW. Nathan Taft Corwin III 0 S. �A• COPIES OF THIS SURVEY MAP NOT BEARING v THE LAND SURVEYOR'S INKED SEAL OR Land Surveyor EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VAUD TRUE COPY. ��• CERTIFICATIONS INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY O IS PREPARED,AND ON HIS BEHALF TO THE TITLE COMPANY, GOVERNMENTAL AGENCY AND Title Surveys - Subdivisions - Site Plans - Construction Layout LENDING INSTITUTION LISTED HEREON,AND TO THE ASSIGNEES OF THE LENDING INSTI- TUTION. CERTIFICATIONS ARE NOT TRANSFERABLE. PHONE (631)727-2090 Fax (631)727-1727 THE EXISTENCE OF RIGHT OF WAYS OFFICES LOCATED AT MAILING ADDRESS AND/OR EASEMENTS OF RECORD, IF ANY, NOT SHOWN ARE NOT GUARANTEED. 322 ROANOKE AVENUE P.O. Box 1931 RIVERHEAD, New York 11901 Riverhead, New York 11901-0965 SURVEY OF d• LOTS 9V & 100 SUBDIVISION MAP OF PROPERTY OF GEORGE I. TUTHILL & OTHERS SECTION ONE p p0o M ' FILE No. 861 FILED JANUARY 15, 1929 12 ° ' SITUATED AT • a•, t. MATTITUCK 4 a b � TOWN OF SOUTHOLD SUFFOLK COUNTY, NEW YORK�4 I , �aNER ° . " S.C. TAX No. 1000- 126- 10-9.3 I of g9 �, o 4 1000- 126- 10-9.4 $ . 4f SCALE 1 "-40' -_.. " JUNE 30, 1995 SURVEY LOT 100 & HEALTH DEPT. DATA a DECEMBER 12, 2002 ADDED LOT 99 g•1�+gyp DECEMBER 27, 2002 REVISED BUILDING ENVELOPE N 6 � N ' AUGUST 25, 2006 ADDED PROPOSED ADDITION P NOVEMBER 6, 2006 REVISED AS PER S.C.D.H.S. INCOMPLETE NOTICE o JANUARY 11 , 2007 REVISED PROPOSED SEPTIC SYSTEM TO A 5-6 BEDROOM HOUSE JUNE 1 1 , _ 00o cISRe ��� `'° �Q `'. 2Q07_ STAKE FOUNDATION " .JULY 10, 2007 FOUNDATION LOCATION 2 44 d� OCTOBER 29, 2007 ADDED SEPTIC SYSTEM Nam. JANUARY 24, 2008 FINAL SURVEY a AREA = 20,086.11 sq. ft. d + 0.461 ac. LO d.. Lit •.a. .n d • 9.3 • o. 126�1 6� �y S.C.H.D. REFERENCE No. R10-05-0020 0/ _ •-00 a. ° AX T�� �10� 10�g'4 N ��� Yr00� E(F� Z� o• �3 26' Np�/ ro 1000-1 �. o Ro°F % _,-�W TIF.LED TO: C TAX Na. Nr� ¢° ."o y wOpD poRc PQ ` - -- 1_:: VINCENT PAPA ENO � Al `b O RE(P�N � �D� 'p0 0 O �. -O. ��'�^O• 03 N_ Now bidMAR ,��°- �. SEPTIC SYSTEM TIE DISTANCES G� COVER HOUSE CORNER "A" HOUSE CORNER"B" o• y 1 ,s o� GATE\ \ + ' � SEPTIC TANK (:OVER 1 66 15 c� �,�1 2 N obs. SEPTIC TANK COVER 2 68' 19, CESSPOOL COVER 1 69' 32' CESSPOOL COVER 2 80' 25' 1 �^ LOT G��v �'� �l♦or� IF MY 1, �-+ �_..,, E^,!.y �r rem t LO Ey9 ♦v �.F t�k. �' ... �/! 1� ��.`1 a�e� 1 f v: �E-� awe w7. ..' a. t s• ; ���, I"t!P �� H.s.r.-���. Q�o—DS-asp Z� 110\� ? The C-710*-1 FM vim'°r V P+rr"-*n tl e?'+t-'O*n t-*71 """► o!�t �11e9�t',Ik t;a� "ar .,gyp,_,.. ,,,'..'"Qi t"+..', ,.'".w..��'"E'!4"�►` .- '°'' Cr,.__.� w 04 be F0ri A?1AXt V 4 07...54� h UNAUTHORIZED ALTERATION OR ADDITION ° �,?!� , h~' yM�•�� TO THIS SURVEY IS A VIOLATION OF ,y , SECTION 7209 OF THE NEW YORK STATE 10 or-S 0•,1a��i./s��r_ _ EDUCATION LAW. COPIES OF THIS SURVEY MAP NOT BEARING n ` THE LAND SURVEYOR'S INKED SEAL OR v EMBOSSED SEAL SHALL NOT BE CONSIDERED •oy. G TO BE A VALID TRUE COPY. Z CERTIFICATIONS INDICATED HEREON SHALL RUN 61 ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED, AND ON HIS BEHALF TO THE TITLE COMPANY, GOVERNMENTAL AGENCY AND LENDING INSTITUTION LISTED HEREON, AND TO THE ASSIGNEES OF THE TUTION. CERTIFICATIONS ARE NOTDING TRANSFEIRABLE. F THE EXISTENCE OF RIGHTS OF WAY ANY, NOTE SHOWN TARE FNOTCORD GUARANTEED. PREPARED IN ACCORDANCE WITH THE MINIMUM STANDARDS FOR TITLE SURVEYS AS ESTABLISHED • O BY THE L.I.A.L.S. AND APPROVED AND ADOPTED Nathan T of t Corwin FOR TITLE SASSOCIATIOUCH USE BY THE NEW YORK STATE LAND ,Sol=h��dy Land Surveyor cod� ,iAFTcOr�•P t sc 1". .1j1 A �. Title Surveys — Subdivisions — Site Plans — Construction Layout PHONE (631)727-2090 Fax (631)727-1727 S�J7 yOF OFFICES LOCATED AT MAILING ADDRESS v / 322 Roanoke Avenue P.O. Box 1931 N.Y.S. Lic. No. 50467 Riverhead, New York 11901 Riverhead, New York 11901-0965 � N G�N� �. N o�5, N I. ►1V�TTEN t91WN51ON5 SHALL FM I'M09MN T OVER'5CALFP DIWN510N5,LAPGMM SCALE MM%5 M12 PLAN5 SHALL u � � "t NAVE;PkECERMNCE OVER 5M,LEP 5CALEM PLAN5, o � N . !dJ 'o ,� N 2.CONT1'ACTGP SHALL VERIFY All DIMEN51ON5 ANP CONP1110N5 ON THE JOB 51TE BEFOW 5TAZf OF CON5TMUCTION• 5Cx(IM FOOfAGE5 } Q o ARCHITECT5 OFFICE 15 t0 BM NOflM19 OF ANY VAPIA11ON5 FROM TIC RIMEN510N5 ANP CONIATION5 SHOWN ON THE - 00 PLAN5. LGT SIZE s 20,08515�S,FI z (D- 3,ALL CONSTRUCTION SHALL COMFL•Y FULLY WITH THE i�TPLICABLE PMOV15ION5 OF THE NEW YOM 5TATE PUILRING CORM M19 AMEMICAN FoI15f AND PAIEP A550CIA110M W00'P FRAME CONSTRUCTION MANUAL FOR I AND 2-FAMILY RWELLING5 A f � � > IIM PPAWING5,fH15&%&L NOT'BE C5ON5TUI2 TO MAN THAT�KEQUIREMWt5 SHOWN ON TIf MRAWI 6 MAY MOiJ EXISTING 15TLFLOOP9 905 5,F. I y 20046 150 I 7� I Of w MODIFIER BECAUSE 11�Y M MORE 5TMINGENf THAN CORM RMQUIREMENT5 OR BECAISM TIDY AM NOf 5PMCIFICALLY - - - - - - - - - ---- - - - - - - �.._..,._m. _� REQUIREP BY CORE, "I;XSVVI2 M�GK�-Zh0 S�F�, �"' LLI _o � 9:MINIMUM CONCRETE STRENGTH SHALL BE 4,000 P.5•I.AFTER 28 RAY5,STEP Al CONCMTE FOOMCA5 AN17 FOLNPATIoN WA.L5 TO BM?ON SOUP LN'PI5TLWB 12;501L,MINIMUM 501L BEARING CAPACITY fO BE 4,000 P.5,F. TROPOSEM CELLAR � 13�0 5.F• if T\ PLu L _ A.A.I.EXTERIOR FOOT1NG5 SHALL BE A MINIMUM OF 3'-O" GLOW FINI51f[9 GM. �!' OP4`C�IST Fi.00t;-�-2960""S;F; u, 1� ; �" B,MIT�.ABS AID SLPPOMfMR ON FILL,11 FILL SMALL BM COMPACTED IN LAYERS. .. PPOPO5W COWM19 POPCH- 9h 5.F. \ v C.IN ACCOP. RZA WITH 5FCTION P402,2 CONCMfF-SHALL I3E AI:-ENTPANEM WITH A TOTAL AM CONTENT OF NOt P OPOSC Wt2 t1FCK lO r \, LE55 THAN 5% OM MORE THAN 17.. L WOOR fO I3F NUMBMM I ISM-FII:OP BMTTEM(F6¢1,400 P.51) ANP SHALL BM STAMPER A5 SUCH OR ARCHITECT PPOPO5EM 2NP FLOOD- 14} O 5,F, PMOPO5N2 CELLAR. 22,3' - -- - - z c W, MEM5 TNF PIGHf TO HAW WOi&REPOW.ALL LINTS L5 to BE(3) 2" x B W-M(2) 12" PLYWOOD FL.ItCH BMTWFFN C 0�0 5,F I) PP 5ED U' "!BECK FOR 6 WALL5 ANP(2) 2 x 10 W/ 1/2 PLYWI2 F MCH BMTWFEN FOR WALL LWLE55 OTHERWISE NOTFP, FAR, 2913% C 21 z A. IN-VOM WALL5 ANP PAR11fION5 SHALL BE 2" X 4" W0019 5TL12516" O.C.WITH 1/2" GYPSUM BOARD 9M AND S PPOP05En 2ND FLOOR _ _ SPACKLER 3 COAT5. I I o �� " �" -$ q< 0 \ (1,�50 SIF.) ( EXI f1NG 1 fMY I o w o 13.EXTFPIOM ML5 TO BE 2 X h WOOD 5TUP516 OIC(UNLE55 OTH !MI5F NOT1 P ON PLAN5 ANP RETAL5) WITH GYPSUM BOAW FA5SW19 TO INTFPJOP OF 5TIV5,,TATER AND 5PACKLEP 3 COAT5.EXTFPIOM TO BE COVWR WITH \ PI?OP05ND 15T FL001: r, '� —�} F RES, 0 rz Q 1/2" Cl2X EXTERIOR PLYWOOD MI?MATH"TYVEK"' IiNFILTRA110N DMIMR IN ACCOWANCE WITH SECTION 022. U, 0 v FXTERIoP FINISH MATERIAL fO It VINYL SIDING TO'MATCH EXI511NG,COLOP A5 5ELECEM BY OWNED, A5 NO02 ON PLANS I (2.960 S.F J („�5) ��"; � = w 6.ALL ROOF AND WALL PLYWOOD SHALL BM CPX EXTFIPIOR 6 AIX AND 5-I&L MMMf TIE MQUIREMMNf5 OF fHE LATEST :' `;r'::/' :•: •::: :: ::.:: ® ,� w QJ EDITION OF THE U5,PPOMUCt 5tANDAP.D5 P5-I,AND 5HiALL BE Ii2EN11FIER WITH TNF ATPMOPPIATE MAMF TRADEMARK OF "' �'�... /fL�pf 6 �C---- j � Tt AMFMICAN PLYWOOD A550C!A110N, - :.:.:: : :' o .No 7 5 F 1 RST STREET ZGNING INFORMATION;TOWN OF 50MOLM G ,;� _ —18 0 _ �� 0 N ANn RANK JOI Sty FM INTO OiI1ER WO(0D BEAM5,PROVIDE TECO U-GMIT 18 GA,GALVANI7ED STEEL JOIST PPOMM ZONED F-40 51NCALE FAMILY PE5IMENCE — NY 1 1948 .A,19OL LF ALL FRAMING UNPEM PARALLEL PAN110NI5,PROVIDE FII�STOPPING A5 REQUII�R AROLNP ALL OPENINGS �AURE 'R' : WD MCK A�t�M N.Y15,CODE. � U5� P,FQU►i�MENTS :� :. ,�: ��. I � � J�� � 13,PROV17c AT LFA5f ROUBLE JOI5t5 AND HFAMEP.5 TAT WATEP CLOSET RMAN5, BATHTUB5,AND AT ALL VENT AND LOf CowwM 20% / W-aMICAL OPMNINC45 2'-0" OP MM IN WIPTFI, MIN,FRONT YAPP 40 FT C.PROVIRM I" X 3" BPJPGING 13ETWEFN ALL FLOOM,JOISTS.MAXIMUM SPACE BETWEEN MOW5 OF BMIPGING ANP BETWEEN BMIDGING ANP SU'POMt5 SHALL BE a-(0", MIN,PEA:YAW 50 FT, ' MIN, 51M YA t9 15 FT �-- 8,BLINP FLASH ALL JUNC11ON5 W1-ERF WMA, YMV..5 HOMIZONTA,, ie;CHIMNEY,ROG'F5,WINPOW5,P00M5,ETC. N 9.WINPOIN5 AM TO MATCH FXI5TING,SHALL it OF�SIZE ANP TYPE NOTED ANP SHALL BE SUPPLIER COMPLETE WITH INSULATED MIN,TOfI SIDE 35 FTI aA55 ANR 5CRMEN5,(MIN,P-1,70).WINDOW ANP POOP HEAM5 TO ICE 5ET At 6"-8" ABOVE FINISH FLOOM. �OCA110N MAC (1569) _ (20.42') I EXISTING 0 A.NFW FXTEMIOM ROOP5 M TO BE INSULATED ANP COMPLETELY WEATHEP5TRIPK19.( MIN.M-2.50). I 5fONM DPIVMWAY - .� B.INTEMfOM ROOF5 ARE TO BE FLU5H,HOLLOW CM WOOF, 5TANFR ANP FINI5HE9 A5 PIMM9 BY OWNFM SCALE:r' l000' 10.VERIFY Al MIMEN5101N5 AN1251ZE5 OF WINROW5 WITH MAN.FPCMI ,M 13MFOMF PFOCFFMING WITH ROLW \\ PROPOSED COV, FMAMiNG,AND RELATER WORK. 51t Not5 PORCH(94 5,F.) II,Al FXtOCK WOOF ANR ALL WOOD P. %NG ON fOP OF CONCRETE 5HALL BM PRE5FWATIVE TMEAS12 WTH OIL-BONNE OfMiCAL5 IN ACCORDANCE WITH AMA%ANDATJ25. I, BiFORE BEGINNING AtTHIE 511E,W1 ERE POSSIBLE �o A.ALL WOOD PO5f5 RM511NG ON fOP OF CONCRETr SHALL NAVE C4&'VR METAL 5M 5 ANIG M19 TO CONCRETE, � `� �I--EXISTING AVP".ou6HIOUK THE COUrU%OF IM WOM,IN5PECf \ �' i 12.PAtCH ANP REPAM ANY PAMAGEP EA511NG WORK TO FFMAN, MATCH EX1511NG CONPIT10N5 ANP MATERIALS. AW VERIFY THE LOCA11ON ANP CON12111ON OF EVMWY �� \ 1 i WASP 5MRVICM ITcM AFFECTED PY TNF WORM.WIPER THI5 CONTRACT 13.ROOF RESIGN LOAFS- �15# $LIVE LOAD+ 10#PiEA2 LOAM- 55#5.F.TOM,LOA21 �o� � AND R>;PORt DISCREPANCIES TO THIi A"�:NITECf BEFOP.E � ,• ��°`� I ( I I FLOOR ME51GN LOA125- -40 LIVM LOAM+ 15 PIMAM LOAM 55 5.F.TOTAL LOA9. �' ` DOING WORK MtATEP fO THAf BRING 1N5PECiTP, tit.Al ELECTRICAL WOW.TO BF INSTA LER SHALL It TIN ACCORRANCE WITH 1HF N,F.C,ANP CHWtIZ5 33-42 OF THM MATit K �° I iT9X-NTIAL CORE OF NY STATE ANP SHALL It U,L,A'F'POVW, 2�� 5� � DISTRICT I � u� ELFCTRCAL CONVKfOR 15 TO BILE FM ALL MQUIMV TEPMIT5 ANP OMAN ALL REQUIMI?CMP11FICATE5. ` 5 8� y pp 2• BEFORE BEGINNIivG WORK Af THE SITE,IN�I'ECTTH — ..�. ..— 1_ — b — �J DO NOT PROCEED WITH y� I5.ALL PLUMBING WORK SHALL BF IN5%LE9 IN ACCOWNNCE W111i CHAPTMP5 25-32 OF TW RM51PMNV&CORE OF NY 5TATE, N� � ,5( E(I5fING BUILDING ANP DETEWMINE 5L EW, OF FRAMING UNTIL SURVEY PLUMBING CONTRACTOR 15 t0 F!I.F FOP ANP OBTAN ALL T,EQUIMMD PEPMItS AND OBtAN A L P.EQUIREP CFMI1FICATES. $ EXI571NG FINI5HL5,sPECIA 11Es,cASEwor , Q I I I ��/ I OF FOUNDATION LOCATION PLUMBING FIXTUS ANP FITTINGS t0 BE AS SFLFCTER q3Y 1HF OWNERS• b ��s EQUIPMENT,AND OfNER ITEM5 WHICH MU5f BE REMOVED 20 16 �7 0 Y " 9�16 6 HAS BEEN APPROVED. �p� gt� Aril?REIN5MEP IN ORDER TO PERFORM THE WORK -- — —___-- -.----_._---------_--�-- -._-_--_-- I 16,ff MECHANICAL 5Y51FM SHALL BE IN5tALLEP IN AC CCOWMa WYM CHAPTFP512-2h Or TNM W51MFM&CORM OF NY 5tATE, \�� q�5� I•1 VrT fH15 CONTACT. 1 G5 11.WHEN IMIZI R A f MATION5,MPAP5,AMMMON5 CM CONVERSION5 REQUIRING A KWIf OCCUR,a INMIVIPUAL L9MLLIN6 UNIT a5( �J��'�1 5 ;0`t 5H&L BE PPOVIM19 WITH 5MM,ALA?M5 LOCAM9 A5,MOUIRED FOP NEW MWELLING5 IN ACCORDANCE WITH 5EC11oN U11,11, � ,5 f < •Jt L�r .I ( 4'9 t ARCNITECTI rRAI DRAWINGS IOUJ PRINCIPAL AREAS WHERE - TIC 5MOKM ALRM5 SHALL BM IMFCONNMCT 19 ANP I•Vw'TJ2 WIRED• 2"a ��'� WOW MU5f BE ACCOMPLI5HED WIPER 1NI5 CONWACf.INCIDENTAL r r4 , 18.WALL AND CMILING FIN15HE5 9i&L BM IN ACCOFPA�NCE WITH SECTION U19 ANP IN51LATION SWV.L BE IN ACCOPRANCE WITH �U,�� V5�5� �A CT WORT:IV!AYA 50 BE NECESSARY IN A1�A5 NOf�IDWN ON THE PP\AY C,.- I�� FINU� 5ECT1oNU20, P/�iTERS Alm!ITi;CTURALPP.AIMNG5PUEfOaNANGE5AFFECf1NGEXI5TING OCCUPANCY OR 19,INTFRIOM WALL COVMRING SHALL BE IN ACCORPANCIM WiH 5FC110N IU02 ANP EXTEFIOP WALL COVERINGS SHALL GE of AMERICA .. MECHANICAL,ELECTRICAL,PLUMBING,OR OTHER 5Y5TEM5,SIGN USE.IS UN L F.ULT IN ACC01�2ANCM WITH SFC110N P'l03 �`� ,;�.,> INCIDENTAL WORK 15&50 FAR OF THIS CONTRACT,INSPECT 20.TM ARCHITECT HA5 NOf MEN P.EM 9 FOR CON5TRUC110N 5WMFVI510N,TNM5E PLAN5 M IN5TMUMMNf5 OF 5MMVICM 5� V19%AITA5,AND A5CERKAIN WOW\WEPEP,AND 10 THAT WITHOUT C E RTI FICATE AND ffMAN THE PMOPFRfY of lit ARCHITECT, U` WORK IN ACCOM WITH THE CONTP.ACf MQUIREMFW5,Af NO OF OCCUPANCY 21,fW A?CHITFCf WILL NOf NAVE CONTROL OVER OR CWM OF,ANP WiLL NOf BM RM5PON51BLE FOP CON5TP.UCTiON 5� � ,4� AVPIfIONAL C05r, PLOT PLAN MEAN5 MO METHOP5,TECHNIQUM5,5EQLJENCF ANP MOCFPLIP.M5 OM FOR THM SAFETY WOGRAM5 IN CONNMC11ON WITH a Gp�A1' 1HM PROJMCf, PFCONIC 5CA F ,- 1 ' ' ` 20' -0' ' S e SAY 5UFFOLK COUNTY fAX M� , TL 1715TRICT 1000 DATE:E:-- = - S.P.#r 5EC110N 126 BLOCK 10 FPE:-_ � cl��? �°: j; C0 AT � � q FO' TIME - y �_ FC)L1-1'+'Ji \'\7 !j` ' 1-1-1.•Ji(�I C. � CLIMATIC AND GEOGRAPHIC GE51GN CRITERIA P`""'"?I''�C F; I ��� 3. INSULATIO`i GWOWP WIND %i5MIC 1�M1�A7 IYINTM ICE 5HIELD FLO 4. FINAL O SNOW M516N PE516N UNPERLAYMENT L', ';-'�'. MJSc SPEEDCMPN) WEATHiER1NG 11105111W 1ERMITE DECAY W301,2,1,21N1ERNALPRESSUP.E: TABLE 150�,2(I) BE CUr.^,DUETS Fi��-LOAD CAEGORYTEMP REQUIRED IMNDO'NS IN BUILDINGS LOCATED IN WIND BORNE DEBPJS REGION ALL CONSTRU ,TiOrJ Sl iA_L 14iEET THE K) DEPTH ASPHALT SHINGLE APPLICATION (PRGPLPTIES WITHIN I-MILE OF COASfA WATERWAYS) REQUIREI,�IENTS OF THE CODES OF NEW -45 120 c 5EWW 36" MOD,f0 5LIGNf II YE5 5ME PLAN5 SHALL HAVE GLAZED OPENING5 PROTMCt[9 FPOM WINDBOf3 DEBPI5 COMPONENT- IN5TA-LA110N REQUIT.EMWT YORK STATE. NOT RESPONSIBLE FOR HEAVY TO MOD, EXANVI�W OR THt BUILDING SHALL BM DESIGNED A5 A PPRfIALLY ENCLOSED BUILLDING DESIGN OR CONSTRUCTION ERF;ORS. O IN ALCO�IANCE WITH 1NE INTEWNA110NAL BUILDING CODE.GLAZED OPENING v I.ROOK SLOPE ASPHALT SNINCd ES SWALL ONL,BC USED ON WOOF SI ODES OF fW0 WITS VERTCAL IN 12 WITS ' . - ;1, T;F!C/�TION PROTMC110N FOR WINDBOPIv'E DEBRIS 5I&L MEET THE PEQUIREMENf5 OF TIC HORIZONTAL(2:12) TOR GREATER, FOR EOOF 5LOPE5 FROM fWO WIf5 VERTICAL IN 12 UNlf5 O O TABLE R30114 TABLE R301,h LARGI=MISSILE 1E5t OF ASTM 1996 AND OF ASTM E 1886 REFERENCED 1WiEWE1N, HIORIZONfN (2:12) IUD TO FOUR UJIfS VERTICAL IN 12 WITS HIORIZONTAL(4:I2),DOUBLE ,, C :-- _.'.:. ;i%N7 ENT BEFORE v MINIMUM UNIFORMLY P15TRIi3UTEn UVE LOAt25 A.LOWAI3LE DEFLEC 110N OF StRUCTPAL MEMBERS WPERLAYMEWM-ICA-1ION 15 REQUIV IN ACCORPAJCE WiTH 5EC11ON 1507,2,8 Ci_ -i ri-ICATE OF OCCUPANCYRETAI N STORM WATF T $'A UNO :'F (IN POUNDS PER SQUAP.E Fn01) ExCEPt"4 N:WOOF 5TRUCfLM PANEL5 WM-1 A MINIMUM TNICKNE55 OF 1/16" - `Y PURSUANT TO SECTIO� INCH PNi)A MAXIMUM SPAN OF 8 FEET SHALL BM PEPMIf1E1 FOP OPENING 2,DECK REQUMENf ASPHALTSMNGI E5 SWN L BE FASIENEPfO SOLIDLY 51ATHED WOOFS, ` SOLDER USED IN WATER OF THE TOWN CODE. STRUCtU'J�L MEA�BER ALLOWABLE PRK; 1,C110N IN ONE-ANP TWO-STORY BUILDINGS,PANELS SHALL BE rMCUr r I SUPPLY SYSTEM CANNOT USE LIVE LOAF REFLECTION fO CO4'ER If GLAZED OPMNING5 WITH AffP0WNf HAMAP.M PROVIDED IN 3.UNMAYMEW UNMAYMEW%&L COi�ORM WITH 15TM D 226,TYPE I,OR A5TM P-4669 TYPE I, � � o r EXIEPJOR BA,CON�s 6CJ ALCC7:'DANCE WITH TA3LE P301,2,1,2 OR SHALL K3E DESIGNED TO Rt:515TT1-iE a � EXCEED,2/10-OF 1/LEAD. tlP,DE�RWRiTERS CERTIFICATE RAFTERS HAVING SLOPE5 GREATER THAN 5/12 L/150 COMA VN\a AND Q Ai21 R25 LOADS DETERMINED IN ACCORDANCE 15f TILL FOR ROOF SLOPES FROM TWO WIf5 VW11CA.IN 12 WIf5 WPERLAYMWf 5HW.Il.BE TWO LA,:TW5 AMIEP IN 11f FOLLOWING MANNER, APPLY A REQUIRED -� qp VATH NO FINI5HEP CET!ING AfVCHED fO RAFTERS HORIZONTAL(2J2),IF TO FOUR WIf5 VEMCAL IN 12 WIf5 MINIMUM 19-INCH 5f0P OR WPEIJ,AYMWf FELTPAP&LEL WITH THE 5fARfING Af THE EAVE5, � O O PWOVISION5 OF fW INIER,NAfIONA-BUILDING QDM, HORIZONTAL(4:12) OR GREATER, FA5SNIN6 5UFFICIENnY fO HOLD IN PLACE, STARTING Af THiE SAVE,APPLY 35-INCH WIPE PLUMBING 0 � FIREE5CAAPEE5 `0 INTERIORWALL5ANDPAI"VON5 H/180 tA13; E r I,211.2 e \, 5HEEf5OFUNPEP1AYMENfOVERMAPPIKU5LM5510E51EET519INCHESANDFA5TENED CERTIFICATION OF >' p� p� I�J!NJ,3ti'�;N REBMI5 PP CTiON FASTENING 5CHEDU.E WICIENTLYfOHOLIP IN PLACE. ALL PLUMBING WASTE (WAILING & CONNECTIONS Z VPP�VIATION5 WATER LINES NEED REQUIRED. z PASSENGER VEN11W GARAGE5a 50a FC 'r''i�iOD STMUICTURA. PANELS a,b,c,d TESTING BEFORE COVERING FLOOR5 AND PLA5TEREP CEILINGS L/360 FOR ROOF 9L0PE5 FROM FOUR WIf5 W"CAL IN 12 WIT5 WPERLAYMENf 5HW I,BE ONE LAYER5 f1fiLIEP IN 1T-IE FOLLOWING MANNER•UNMIIAYMENf A.F.F. MM FINI5H FLOOR IN. INCHES d Af11C51MiHM 5fORAGE 6,e 10) Aft, AffACWV INf, iwooR FASTENER SPACING HORIZONTAL(4:12) OR GREATER 5HALL BE APPLIED ANaX FA5HI04,PAZ&LEL fO ANP STARTING FROM THE EAVE ANP LAPPEP AIAIM, ALUMINUM IN5LL. INS ACIN ALL CONSTRUCTION SHALL o ALL Off R StRUCTI!'fJ MEMBERS L/2�t0 FA5TENEP 2 INCHES,FA5SWP MY A5 wa55AKY TO HOLD IN PLACE, DLVG PULPING LB POW � ATTICSIMTN SfOi'AGE b,e 20 PANEL 5i% 4 FOOT' 6 FOOf MK �-� MEET THE REQUIREMENTS OF THE � TYPE _ VI.r� MC)CM16 MAX. MA'JMR � CODES OF NEW YORiK STATE. n w < FOOT < PANEL SPAN < PANEL 5PAN IN AREAS WHERE TIC AVERAGE PALLY fEMPERAfU IN AN ICE SHIELD 1HAf Ci0N515f5 OF AT LRfSf 1W0 LAYERS OF UNDER AYMENf CEMENTED WCH NfO ANICN ROOM OfIiER THAN 51 EEPIN,ROOMS q0 EXTERIOR WALLS WITH PL,g51ER OR 5111CC0 FINISH N/360 - - ,IANUARY 15 25 DEG,F.OR LF55 OR WHERE THERE 15 A PO551BLITY fO6EM OF A ELF-ADHERING POLYMER-MOPIFIFD BITUMEN 51 SET,SHALL BE U5EP IN C.J, CONTRCL JO1Nf ► 69 MANIVAGMIZ �\6 FOOT < 8 FOor OF ICE FORMING ALONG fHE EAVE5 CAUSING A BALKU'OF WATER LIEU OF NORMAL UNP>ER-AYMENf AND EXTEND FROM fHL EAW'5 EDGE fO A POINT Af LEAST �G aL NG uNE t 115NC, WNM�,W C16 SYMPOL K�Y Q SLEEPING ROOMS 3© - 291NCHE5 IN51M THE EXTERIOR WALL LIT OF,HIE BUILDING. CONC, CONCMft M.O. MA50WYOPENING" O 0 EXTERIOR WALL5-WINP LOAPa WfH BRITTLE FINI5HE5 L/2-40 2-!/`; #6 CONE. CONTINUOUS - 5fA� 40c 16" I� � 9" VIA. VIAWSIZ KI. NOf IN CONTP.ACf N WOOD 5CPEW5 4,APPLICATION AfTACHMENf A5PNALf SHINGLES 51-ML NAVE fit.TYPE AW MINIMUM NUMBER OF FA5TENER5 REQUREP DWG nF?AW N.T.5, NOf f0 5CALE 2 ELEVATION LI MP n EXTERIOR WALL5-WIi V LOA17a M FLEXIBLE FINl�5 L/240 BY THE MANITACTURFM,FOR NORMAL AHf'LICATTON,A5PHALf 5HII`aE5 SHALL BE 5ECLREP TO A-2 SHEET NUMBER = � GUAWDRAR.S AN,m HUVJDRALS d 200 _--_ EA EACH O.C. ON CENTER — `� � THIS ROOF WITH NOK LF55 TI�iW FOUR FA5fENER5 PER 511Z P 5HINGLE f0 TWO FA5fENER5 PER FL, rt&AWN OPNG OPENING 2-1/2" #� „ �i „ INPIVIPI Al.5HINaE.MIZE IHL R00P 5I.GPE EXCEEn5 20 UNT5 VERCICA,IN 12 WlTs ��C, E eCTMCC(AL) PL11Nf7 L 0 5CHMLU OF WAWI NG5 �A W � a.ELEVAtED GARAGE FLOORS SHALL BE CAPAT�LE of pl'ORTING NOTE:L-SPAN LENGIII,H s SPAN HEIGHT r7 I6 1611 12 HORIZONTAL(20:12)),5PECIAL MEM5 OF FASTENING ARE REQUINT19a• FG �G� P,S,F, � 2 M D i,55FCflON NUMUFP,, f` a � WOOF ` W5 FGIJIP. FOLIPAW r.5.1, ns �i�c A 2_,000-PU9�1P LOAF N'PL�D OVER A 20-SQI.IARE-INCN A'P.E{A W.Jr VWAN510N JOINT A-2 ` > 6.NO 5i* AGE WITH ROOF SLOPE NOr OVER 3 WIf5 IN 12 UNn. a.T{ -WW LOAF SHALL BE PERMITTEP TO BE TAKEN A5 0.9 f1ME5 THE __-- EXf. EXTERIOR R,a, RinG> DEAR A-1 COV�, 5H�Ff, t'Of PLAN and N01�5 u w c.WVIPIA 5fAIR T�AP5 51A L BE PE9MP FOR fit WIFORMPI.Y COMPONEW ANP CLAPPING LOAP5 FOR THE Pl�PO�OF THE FASTENER5 GALVANIZED,5fA -1. 55 STEEL,ALUMINUM OR COPPER ROOFING NAIL5,MINIMUM 12-GAUGE MINF, �WFOU OI KEY TO POOP 5CHERULE af � �� F.V. FLOOK VRNN �ea'V �QUI�V � PI511�MP LIVE LOAP OR A 300-POWP CONCEN KATEP LOAF DETERMINING PEFLECTION LIMIT5 MIN, a.TH5 TABLE 15 BASER ON 110 MPH WINK 5PEEP5 AND A 33-FOOT (0,015 INCH) C WITH A MINIMUM./8 -INCH PIAMETER HEAP,FA5fEKER5 SHALL BE FIN, FIM5i PM ROOM � r ^2 �OUNnA110N CON511�UC110N FLAN LONG ENOUGH TO PrNE1RAfE INFO 5Cr7WNG 3/4-INCH OR THROUGH tHIE 1NICKNE55 OF FR. I0515W kk Poor PRT A KFY TO WINDOW SCNFPLiL: I ! AC nNG OVER AREA a sQIIARr INQ S,WMQ VERPROPUfCEs MEAN P00F WIGHr. I A-5 F,I;5f FOR, CONS\UCION PLAN 1HE GREATER 5TM55E5, 1HE 5HEATHING, GA, CAE 5IM, 51MCIN 6,FA51 fl M5 5HALL PE IN5fALLER AT OPPOSING ENDS OF 1HF 6-V'n CA-VANIZEn rcr5 �'oo°Nrs 100 ROOM NUMBER I /�-�} S�CONn FI.00� CON511�UG1"ION pI.AN J.A SINGLE CGIJCENIRATEP LOAF APPLIED IN ANY DIRECTION At ANY CAP. GYPSUM 60A1?n 56F. 5UTMr T � � POWKAI ONG THE TOP. WOOL?5TP.UCTUM PANEL. FLASHING PER 5EC110N I501,2:,9 G.c, GENFPAL COMiMfOP 5.C. SELF CLOSING � pA'.11110N TYPES � A-5 �X1�pI0p �i�VA110N5 e.AfTIC5 CONTk1 IC1EP WITH WOOF 1RU55E5%&L BE M516WP IN HGf HIEGNi' T1 iK, THICK G. NALS SHN,L BE TOP COMMON OP 12M BOX NAILS. H.M. HOLLOW M fAL �• 'I A-6 r-X1�I?IOI? �I.MIION5 and 5�GV ON5 ACC0�7ANCE iMiN SECTION RB02]0,1 a,EXCEPTION;ASPHALT STRIP�IING�,ES SHALL NAVE A MINIMUM OF 51X FASTENERS PER SHINGLIE WHIERc THE ROOF IS ONE OF TH1E FOI.LOW!NG CATEGORIES, t,0,5, t�IM OUT SOFFIT H 1.SEE SECTION R5o2.z.2 FOR DECKS ATTACYED To Ex,ERIOR wA GLs. J.WNW, 50MEW5 ARE ATTACHER TO MASONRY OF,MA50NPY/51U000, v,s, vALLEY SI EEPER A�- - - COLUMN and GPIs NUP��B;=!: w O z I.1HE BASIC FASTEST-MILE WIND SPEED PER FIGLI 160915 110 MPH GREATER AND SAVE IS 20 FEET OW HtlGI[W ABOVE GRADE, A`7 I-13CAM n�1'A11.5 and pl.UMI3ING HIS�f? II�EY SHALL BE ATTACHED UTILIZING VIBMA11ON-RE515TANT ANCHOM5 2,1E BA51C FA5TE5T-MILE WINP 5MED PER FIGURE 160915110 MPH GREATER AND fHL IMPORTANCE FACTOR IN fAMF-1609.515 I.15, W� 'Ern � \ -) O HAVIN.'A MINIMUM UL11MATE WITHDRAWAL CAPACITY OF 490 POUND 3,THE BA51C FA5TEsf-MILE WNP 5PHIP PER Flag 160915120 MPH GREATER, M G OO r�'zo'o' WPVCAL ELEVA110N I c N W.W.F. MLMPwMI`ARIC — NAIUIN6 5CHR)1� 5 and COWC110N MTAI�5 Q MARYLAND MICHIGAN MISSOURI commmm%yr.wINDIAN CONNECTICUT PENNSYLVANiA NORTH CAROLINA NEW HAMPSHIRE _ RHODE ISLAND NEW JERSEY _ _ VIRGINIA FLORIDA NEW PORK - n — e Er'ci) r- U-) N co -- I N 1 I C) w c III II v J 1 � I p 1 W : :.•��-ill I=III=I� � J - • •:o•: •'_•I—III=: . =III- ( I � o w in loe I IIII N,0M:I,11-2X i Lo — _ w MIN 24' a 8'-lo e' Io 8 -10 22'-0" I F- > 1 I D ffIC& 5tK12 F0OMCA b��'Ail. I I I � I- w I 1 � Z 1 I 0 0 I I W Q I I wft� U F- 12"n1A,roar Comm-1E mr, I I U Q EXISTING WU5 WITH 4 X 4 NA7 P05f ABOVE. (TYPICAL) ( 1 w TO REMAIN _ I I I N EX1511%WALLS (2)2 " (2)2"x 8" (2)2" r — — — — — — — — — — — — TOmREMOVED I I l ro = 1 1 xl'-8" I i NEW 5w WALLS N I= v_ m I 'ANPERSM 'AWNING 69VMIZE12 MCTA. I �XI511NG 1 STEP FOOIING nOWN 11 N I 1 I C�I.I Ap �v �, 31 AREAWAY A5 WQ P, `O 6"X6"KAMPOCKETIWO ASREQUIRCn. I " . ( (TYPICAL) NO1E Ixl I <UNFINISNEn, FOUNPATiON WALL W/ NON `� I 1 NEW BEARING SfIY)WAI LS I,2 `KINK GRUUi, I ( 211 x 8"C .LEnGC'LPG BOLTCP -- 1 i _ I NOrWITABLE) TYPICAL ALL A_8 M,MIN 16"O.C.SfAGGERCP I I '+' ..•Y� = :.':� NEW FOUNDATIONWPUS ° 4 a ° d a d — I FF I REMOVF EXISTING I N I X 6"BEAM POCKET INTO - I FOUNPA11ON WALL W/ NON — — — — — - 13ILCO POOP ANn I I STARS A5 REQU! n. 1 ° ( MIN.24"x�O"ACCESS I ;n v 5Ht?INK GROUP. — — — — — 8"X 12"5 MEWn WJ159M ARUM.FOUNPA"VrWfO BC �v t0(PAWL SPACER v NOT('X' 1 1 UNnCN'IN EXI511NG PRILL INTO EXIS G FOLINPATiON CORNER WITHIN 3'-0"OF EACH i I 1 FOOTING A5 RCQUI P WA-L,12"rr &BOTTOM C/',�-�I /�I n I y� CORNER AS�1OUViJ.0 TYPICAL.) I f�IC& I VC'115 I a I I "3 I I ANn 5Er18"LOW, 5 POn5INTO of ILLCP NOI ES&5M vi WITH I _ . p1;01`05�P ExcAVATEn I. PLL A'i'ROVED WORE f0 BE INSfW I En IAILL BC IN PLCORDANCE NMFI I a' I ' c� IN7rAll 3-I/2"SiL LW I Y CO1 U I 0 CPOxY. PCv TO CXTE INFO 1 8 POMP CONC�TC _ u C�I.I.Ap _ '} 1NICK P011REP CONCRCTM SLAB VJI1N I � CXI511NG WALL 5"C TYP Al T}E N.EC AND%U M UL.APPRMV.ELECTTRICAL CONTI"PCTOR 15 TO FILE " v� II " I — 6x6/I0x10 W.W.F.ON 4 MIL VAPOR'BARRIER FOR ALL TTE RMQUeP PERMU'S AW MAIN ALLL REQI BRED CERTIFICATES. 1 v_ ON A 2'-6 x 2 5 x I -O Er - FOUNnA110N WPI L5.(1WICPL) 4. I W o N - POIMP CONCRCTE PAP.PROVIPC C UNFINI5 M ON 4 CARANILLAR CAMPACTEP MATCRI& i I NEW WPLL CONNCCION5 ���-7 Wit.-� C,y 2. PLI,UNDEPSI.Afj WING`i W.L BC RlW IN CCONI7(yf. .a '�' - �� .. I I n I I I S AIR X 16"POUR' �- <'}) #5 BAPS EACH WAY, NOf mitAB1.M) `" I �t� O G�' A. CONDLY_fOR_5 5IALI,BC COPPER,GCM'-RAJ.N wrH 600-VOLf RATED IN511- u C WAU CIRCUf Wi<l%MIMWN 51ZM,#14 OR'#12 fn"IW'OR"NCI"ASREQ. ( _ N ONCKMIM FOOTING. P� 1P.U31NG, A�IMT�517�6Y ONE ON ALL f3RA1JC7•I CIRGUffS OVOR 100 Ff W LENGTH. I � � (TYPICAL) ca d ° I I Pr� d NOTM IX, v ul r 1 4 ;, m r 0 i. CC�lAfS IN GROW?UNDER CONCRETE%Af3 OR EXPOSEn f0 EXTERIOR �# ;� 5iU 9 GM.VANIZED RIX St . 16'�I1 61�11 d _q 8-10 6 .� 6' 9 1 11 J 1 11 1I /I_9II /_1 All hl_(,11 -- 4. ALL 51WQ•E5 AW ffa ffiM5 TO ICE MCAMP FLn,Cc29WING TYPE ° -- C I� 7 �T RATED 20 AMPS;COMFI.Fff WiM WPI-I.M,ATF°5 COLOR AS SELECTfn f%Y O 1W�.R, y y " " A N�EAII�ERPROOP DI1'LEX RECEPfAGLES(Wn71CnTEn WY)91/V,L PO RntEn � •A � a ca «) 2"x 12" ' . (�) 2 x IZ ° i 15 AMIPS WITH STEEL WEATIEWWff COVER MATE, d_. A 0) 2 x 12 A.o (3) 2 x 12 IT <3) 2 x 12 h ib L I I a:° ° 5. INSrAl.L.I dJCiION BOXES FOR LIGHT F�ill4�5 WHEN SHOWN AS INDICATED ON THE DMWNGS, VERIFY LOCATiO N5 OF FIYM OIlUf5 fO CK15E a' — NO INTERFERENCE IM1H PFING,EQUIPMENT;N4V ARCFg1MCTLM 1REATMENr. i = " 11 " I 1 y " " 1 c� C3) 2 x12 C3) 2" x12 2 x12 _ I 6. WALL ALL WIRING FOR MEC11.E0UPMEPtr'*V CaKP.OL5 KLLVIN16WAL 1 - - - , e LW 5.WOf WATER I-EATERS,CUI.5f I".ETC:. UNFXCAVATr;l7 4 � -� I o I •4 MIN.2"CrMYclY 5LAI3,MIN. 6"X 8"KAM POCKMf INTO �- D 9, LEGEND,WY(WATER PROOF).GFI(GROl1JdD FAU t INCERRLPTER) I 18 BFLOW BOffOM OF 1015r5 FOLfJPA11ON WALL W/ NON 5 8 b' P" 6' qll I 5HRINK GROUT, 1 a I -• �I " " II -II 1 " " I d III 1° " " 11 II �c- Cy>) 2 xl2 d (3) 2 xl2 (3) 2 zl2 L3� xl7_ - (3) 2 xi2 as (3) 2 xl2 4 �'. a :• a a UCTIC& ��G�Nn = ( LTD �� I I Imo: L-- ► I - — 1 b"X 8"BCPM POCKET IPtrO NEW WCEPQat,COVER PLATE AIV Wk,INSTALL 18" ° �v y N a I� ABOVE FINIS}En FLOOR IUE55 Of1•ERWIISX NOTEn I >< _ I I K FOUNnA11O1J WALL W/ NON - O 5;RINK GpOUf, STOP FOOi1NG nUWN A5 REQUIMP. NEw 1-LooR IT-cwfPar.COVER PLATE AWD BOX 1 % 1� II-2/8"TJI IIO SCRi 5 FLOOR JOISTS II-2/8"tJl IIO SCRIMS FL JO15T5 1 - � PEW COILING MOUMU12 RECUKNIE,COVER PLATE Al d7 �I6"U.C. c I6"O,C, I ° I II-2/8"tJl IIO SMPIES FLOOR JOISTS UN�XCAVAtP ( O 1 IN51A.L�-1/2"51L LALLYCa. i I 1 . _ . 1 ® c 1611 O.C. 1 . a . a. �! 4"CONCRETE SLAB REINFORCEP + PEW RECEPfPaE,COVER PLATE P1PJD BOX(INSTALL 18" I L 4• ON A 2'-611 x 2'-b''z I'-O"ABOVE FW151•ED FLOOR LUE55 OTl�ERW%NOTEn � vPont?CONCRETE PAP,PROVInM • N A WITH*4 I'O/10 wff-OVER WELL 4) 5 BA5 EACH WAY, ( 1 0 / 1 ( TAMPCP 4 BLIV--TONE FILL, NEW SWifCF1,COVER PLATE AND BOX WSf,A.L 54'' PITCH MIN,1/8"/Ff TOWAR195 POOR ABOVE FII`mI2 FLOOR LIP NEW 3 WAY SIMfCN,COVER PLATE M67 rj(OX INSfA.I.54" _ �` "X16"BEAM POCKET INTO 1 I ° d ° d 1 O I O O I ABOVE FINl5I ED FLOOR �? I 1 FOIAPAfION WALL W/ NON 0 1 1 N 51�INK GROUP, -s • PEW OWPER 5LIPPLIEn RECE55En FiXTUM I INSTALL 1 i Q REOItlRcn WOOD ft0aIPIG TO S"0u fFIXm b i O STOP FODt1NG DOWN NEW UWNER�I f'PLEn WALL MOUNIMD FDXTTKE IN`JrALL d. e. a ; 4 A5 REQLIREn. I I xt N I 1 I i ', WOMP WOOF BLOCKING TO 5LPPORr F IX11 P NOW ONR -R 5L1'PLIEn(Z-LI�MOUNTED I FIXTURE WITHib - c' I Q lL �- © FILL 51rdNG INSTALL REQl11r�D WOOn BLlOCKING TO � � ,,, SLI=PORrFIXTI ° % 1 I— 15 PEG• CABLE TELEM51ON OUILET,11J5TALL 18"ABOVC FIM�I 4• 11'-111 TYP, FLOOR LIU55 OTI•ERW15T'-NOTEV 4 � 1 • \'• ° e � II-9/8"TJI IIO SCRIMS FL JOISTS nF55 OOTFERIM%NOiED 18"ABOVE FIM511 FLOOR 16"O.C. v •� I —� v I N � Os aLIPIG WIM17 SMOKE DETECTOR,IN-5fA UP ONQIN m 5EPERAiE CIKCLII' 6"X 6"BMM POCKET INTO Q `�' Z t 1 CO FOW7ATiON WALL W/ NON CA);T�ON MONOXIDE DETECTOR,IN%All IPA"ABOVE o 5HRINK GROUT. � 2'-411 8l1 STOP FOOTING nOWN � Q FIMSH FLOOR UKLE55OTI•ERWM5E NOTED w A5 KQUIF.EP, PEW E olfff FAN,MIN 70 CFM•DUCTED ir0 O11r51DE, 4 ® CAPmv WIM SCREENED LOUVER. ❑ ❑ ❑ ❑ e I� JIW PION BOX.COO13 MATE WN OJ+TER:ON LOCATION, o O H ,Q \L8"THICK P.C.CHEEK WALL, fl tl 5TCP DOWN TO CELLAR FOOTING, - \ Cn 1 G'_011 2'-I" 2'-0" 5'-6" 2''0" I'-5" 15''8" I'-5" 2'-O" /I.611 2'-0" I'-5" 20'-511 U/ W N FOUNPAWN CONSTRUCW N PLAN pPOPOn 1,310 5f, CFL. AP. w O z —) O (, . MARYLAND em MICHIGAN MISSOURI INDIAN CONNECTICUT PENNSYLVANIA NORTH CAROLINA NEW HAMPSHIRE RHODE ISLAND NEW JERSEY VIRGINIA RPM FLORIDA NEW YORK I Inlee r N� � � N op 1 W O ^ Q 1 �^ z zco > �- 1511NG �X1511 Q o w 1 P p00M C3�n OOM 0rn J W o w I Im = � w > Z � I Q Of z �'-I" 4'-I" 5'-y" 9'-10" 6'-8" �., ZD — J uo Of 24'-6' �4511NG W w PATH V �- z r W � a w N �X1511N6 J CL %0 Lo ON To GRAnE niNING pM N 2R(8-1 4"MW l' .� 1 IMy n�CK V.1 V pPOpOS�n �� I .�� 6'-8" � 0,/ I �N1�t?1"AINM�NT : 2'-II" 5'-�" Z'-II" 5'-4" 2'-6"x6'-8" -6"xb'-8" `�1 „Mlle 5 •� �, 6, (2)2'- T-II" (2)2'- "x2'-11 }` ,p0 6 O I AAA 'M1nEP5EN'#400 SEES "M1nE EN"400 SEP�S PAN' 4C0 SERIFS y'-il 6-8 "ANt7EP5EN' 400 SERIES b oN rv"m 8APLR 2 �' „N\Vr N'400 5FIT5 "MMN'400 5t OF5 CA5rMP -MIT55 CA5EME -eC 55 685 "ANnEUN, M5 F 685 � �� -6° \ s �� CA M W CASEMEN( I _ 3 CIM3 -- - - - 55- -- -- -- - - - 5yy - - - - - FWN BAPLK ��i �C / ,;; 0 /ii `ems — — — — ———— — — TWICAL 4 FYJ UST FANnUC1En I� I c,�l�w _ m Al CORNEP5 I t0 XTEPIOP 6° <2>II 7/8" G P LAM LVL - I ` 9 (2)II-7/8" •oE 6-P LAM L ao 6"x4" r b11 FLUSN O 6"x4" 3 0 0 0 6,1x41, `fl Wn POSE i Wn POSt K, W17 P05t c�i+42i+4z' P05r 2'-6"x 8" I rao5. o o ZE N � I 2 , (`+ Arric AccEss — r` � G— I �XI511NG i L - - 6„,�, krN o I GP.�AT PM / Ot'OS�n I/ wn Posf PkOp05N2zz 1 Pf? ( I PPPFWtK 5T MA = � v MA51�p P3 PFOOM I I Pt;OpOS�n rkop05N) x I o I I KITCHEN I g o I I FAMILY kM _ IGkIEFFICIFNCY<FLIELE55), v 3' " 6'-8' PUMPICATEn 6A5 FIREPLACE,W1TN _ c TEMP u aA55 n00P5"IfAf-N-GLO" 6"x6" N MOPFL#60001RI.SEE nEfAJLS o 8 � I II 13ATN - z I �- - - -- - - — '— � I I C,FI+42,1 — - - - — — — — — — — — — — — — — — — — — ;`• 1 •5 �, T-0„ 31-0„ � pt;OpOS�n 4 + 2'-6,x 6'-8" t4 <3) 2 x 12 — — __ (3) 2 x IZ ——— —— — (3)II-7/8"2.0E G-P LAM LVL ( Rn, oSEn LAUNnt?Y / �' - - - - - - - —�-- - ---- - - - „ ELLl5f1�— Za 2'-6 x6' I Q 6"x4" T.0,5, 6 0 t.05, 6 rb 6,x _ �XI511NG / �4 x 30 1 ' WZ PoSr m POST w PO5T Wn 05r ( �� I Wn I�CK of _ I / W.I.C. 5' 4° 2'-6"xb'-8" \_ � _ / � � � I � 17K''rEt;'I'ENrI�lC1En n p 14k(6-1/4"MAW 6"x " O A r0EX11�R10P 3 Qp <2) 2 x 12 3 (�'MR) 3 (3) 2 z 12 Wn o5t 2"x 12"PInG> BEAM_ — z i o f0,5. `� 6„x4 2!'-6"x 6'-8" Z' 6"x 6'-8" 3 �" I e - I 10 �' LIN. _ WnP05T 1'-4" / ' z Kio°v.s. = c i �/ PROVIT 3'- Y'x V-O'Wn PLATFOPM, I Z r--- — — STAID ANn RAILIN65 If(2)OP MOPE I O N 4"011 / ,BPS APF WolA V o - I rkop05�b / 2'-0" 13'-6" WnP05t 3'-4" 6" 13'/4" 4" 19'-5" 6" I v c GA}ZAL,E noon — I N I I 61,x4„ n1N NG f?M \aPENER o (N Z 6",6, Wn POST r I z SL _ pt; OS�n / Wn POST // (3) Z x 12 Wn, 1Z W p05f ~ O O FLUSH GIPI P 11-1/8"fJi IIO PIES FLOOR KJI5T5 III 11-9/8"fil uo SE IES FLOOR J015r5 GAp I U Z ' OR05En1116"0 , _ MA5Tp 13ATH I I I 0 \\ \ up � N o Pt?0p05�17\\ 4"x4" 16 R(8-1/4' MAX) ti `s LIVING t?M — wro Posr 15 rP(9' MIN.) PPOPOS�n vl•F. x i @ 16"O.C. , 6 x�} vI/. �s, rL / K�PAtE HOOK �i I -� O — i, ev,O ' Wn POST — �) 2 x 12 Wn P05T OPE{�ER q ( •, N 21 l x6 1,P,R, 2"x6"RR. � c s I CL05. CL05. 16"o.c. 16"oc, �G O - I I 61101 „ „ q I vvv P05r q< 02 x 12 Wt7 Po5r N _ P�51GN 6 x4 PROP.COV. 6"x4" � - I 5 5� I\ �-- T-4' x3'4' 2'-4"x '-4" <DI'-5'x5'-II" ( WVP05fI I (2)1'- "x5'_IIf' :o m "ANITUN'400 5FMr5 "MVrMN"4 5EP� "ANnERSEN' 400 5FRIF5 2"x6"R.R. POPCN "x6"R.R. Wn POST "A mm- '400 5FM5 — — — — — — — —— — — — — — —— — —— — '56" MIN.5TA k WPM \\ \ C ` mr-w CA5EMFNf C JAI W = @ 16"O,C, @ I6"O,C. = MENr 2'-II"x 5'-4" 2'-II"x 5'-4" 8-114„ MAX.m5EP Z C 135 CIM3� CPI'6 I ° I 2 xb CJ, I ° I P16 �� Q I I NI I @ 16"O.C. nN TO I c� I ANITUN 400%M5 ANtT\5 00 5WE5 9 MINI.MAP Q �v 1, 12 P(8-1/4" ) N CAS1MENr CASs NT } 4 x4 4 x4 c 4"x4" 4"x4" �{� �SEt2 x 1�EAI7= MINIMUM 70" MAXIMUM 77-I/2" of TP(9"MIN) 55 CXiM55 " , " Wn P051I WTJ P05t - 8-1/4 RISER x 9 T1At7-�4-I/�} T01 PJ -COMRLIES C 2 2"x8" �' WE w POS Wn POS fl — — - - - - - - - - - — - - NOTES: -' W 2'—6"x 6'8" T-6"x 6'-8" Q Q "ANnEPSEN"1400 SEPS "AN(7EP5EN"1400PIFS I.ALL STpUCTUt?AL WOOn MEMf3ER5,lE;R00F RAFTERS, — �- fl CEILING,1015r5,FLOOR.JO15T5,GIRJ7ER5,C3EAP,ING WALLS, n ,� FNW 685 _F 685 """x" '-il"x I'-9" ETC.r0[3E OF HEM-F1R#I 01?GETTER UNLESS Oil-1ERW15E - "ANPFUN"1400 SPIES CALLEn OUT nIFFEFENf, ELL c& 2.ALL EXTERIOR MCK LUMBER TO I3E ACQ(ALKALINE — c Z E Copprp,QUA1?TERN/�RY) a EaN., LLI O 2" I'-6" 10' II" I'-6" 12" 10 J T-9" T-6" 1'41 1'-9" 1'-9" T-10" 7'-I O" I'-9" 1'-9" 4'-6" I I'-5" 4'-6" IM1�OW NOTE; U W ,� Al MINOOM5 TO HAVE EMERGENCY 4'-4" IT-O" 2'-1" 2'-0" 3'-6" T-O" i'-y" ly' 8° 1'-y° 2'-0" 3'-6" 2'-0" 1'-5" t �' 20' S" EGRE55ANn RESCUE OPENING WITH THE FOLLOWING PIMEN510N5: -CLEAR.OPENPM3 AP.EA OF 5,0 5,F.(6I?0M FLoop) a -CLEAR,OFE MI,E AREA OF 9.7 5,F,(UVMR FLOOR) -CLEAR.ORENVLE WPM OF 20" lo -AFAR OFFNAPI,E TIGI't(OF 24" F- �I ,5' F�00P CON5VUCTION PLAN - G w z PPOp05F1��;96'05f, F15TF100P, o g p1;Op05F 194 5,1', CO=EP POrCH J N o MARYLAND MICHIGAN MISSOURI - INDIAN - CONNECTICUT PENNSYLVANIA NORTH CAROLINA NEW HAMPSHIRE RHODE ISLAND NEW JERSEY VIRGINIA FLORIDA NEW YORK - VQ Ljr) 00 r�- c\j cp W) of-- -41 3.to ExNAUSrFAN VICTEp j 7 Lu 'o %--1 >— co fo Extom Z -- ly- 0 w -- ---- ---- - - ---L 0 --- -- - -- --- - - -- - - -- - - - - - - - - -- ---- -- - - - - - - - - - -- -- - - -- -- - - - - -- - - -- m -i Of w 0 w 1I I II - � j I LLI o � Ld Lj :D cn 2411 w 5011 Aff]CACa55 w z II 2.-011l 17'-5" 141-11, Z) :i 0 0 u w LLI w < w ) a OFFN fo PF0W — - I-, I `� < .' �/' I j w IA C) F1?OP05N2 w< 014 IL \0 L0 1 i I i - - — — — — —— c\j — — --RA — — —— — —— — — —— —— — — —— —— — Pol g PAS u . Ll- 6 "j PP,0P05N9 Fr\0ro 2"x 12"076E corlp'll2orl ET-AM FPIOP05�p C 5toAA6 Afll ED QUILT CL05. 2'-6" x6'-8" —— ——— —— — — — — — — — — ——— —— —— — — Af� LA. d/r/N/1'q (2)2'-0"x6'-8" (2)2'-0"x 6'-8" (?)2'-0"�6'-8" (7)1,-o"x 6 -811 +-511 Omit .41-811 V-61' lt0w x 10"CEILING Jol* 2"x 10"(PU J0155 2"x 10"aLIN6 J0155 @ 16"O.C. @ 611 O.C. 0 16"0,C, / i ( I ON pED AAchi -X' PrQP05�1? FP\0P05Ft? \E3 Mpkoom to PWkOOM #2 x ao -6\ 4 ,0'-611 6"6" L 2'�x6 FR 2"x6" 2"x6"PJZtjo4 2"x6"U. 6 0.c V4 —el e—o'—c. -4 @ 1611 OLF-4 @ 1611 O.C. TI IT ')7'-1 1 MMMN',4')0 5ME5 IL "MMMN' 400 5FRE5 CA-cV&'140rf'5 � — — J cASEMEt�r-EGi�ss L J y'-411 CM A55 -1111 V 5P-4" 1'-5"0'41 "ANMM-N"400 5=5 "NM6EN"400 5E X5 'Nv r5eNll 400 5EPE5 MMUN"400 SKIES "AN Xr-5fN'ljl005rRlr5 "MPFP%N"I-100-4rX5 CAD EW CA5FIAM CA5E 9Nf CA569W CASE Nf CASE "I Ca 5 cri 5 MMMN 400 5,:m5 PXlX3rN'l 400 VE5 CI EfG7 C rfor 9'-711 71,011 for or 9119a X Twr&ro(y CON51Ullom -2"Y,4"WV POOP T)155E5,24"(X -A9liALf 59Nae5 ol #FELT LMW1811 OVER -5/8"Extom cm rLwwoop -EXTEW FW5 Or M 16"MYOW 51MWA-L5 ffww wili WRiU9 WAL Icaf if MR. LOAD PATH XAP PATH MCK Poor CON51unoN -2"x 6"R1126�MAM 5�CONP FILOR CON51RUCTION PI -21,Y.611 R00r WN5 @ 16110,C. PP\OP05N21,450 5f, 5�CONP FLOOP, -2"x 6"VALEY 5LffKR5 -5V 8"rxfrlaop 6m PLYWOOV LOAP F'AfH -15#RLf LAMP lall MR 49'Wf 51INW5 -fXlfNt9 W5 OF R00r 16"6EYON19 5176WA15 BELOW WITH MTV\ANt 50Fflf MR. ELECTRICAL + iACCESS \9\ -x X x x x x YXI Y, Y'A X x x x Y, 'y' x x x x x Ali 1 111 X X X X X Xx>�k y FINISH aUN4,4, 08 5/8 1219 0 mml —XI 6MUFE 38 1/2 197�8MMI MAN FOR 5FZE- -12"PAff IN51LA110N,R-38 WWOW WAI?HFlair'-K --T 4 -1/2"GYP W LWR T t DO 24 5/8 1625MMI VVICA,EXTERIOR W&L WWWON 22 [559MMI Prop05rp L -1 -2 X 6 5f1l25,16"OC WTH(2)fOP &(1)POrfOM PLAlt 9 M. [XPP,00M -(2) 2"Y 6"TITATEP MLV 51, 3 1/2 19014M] [�AM -9 1/2"PAff IN5LLA110N,R-21, MCA FLOOR COWWON M. GALV 12 VWE 5EU -1/2"EXTERIOR 6EAM FLYWOOP 10 1/4 (259MM 42 11067MMI Lij -II-7/8"fa FLOOR J015T5,16"OC -51LL 5e v -TMK PULPING MR -5/1"T(A MYVYV 9MOOR,5CffVkt2&WE[? -5502C I 60L1;6'(.(. -vm 511V4 -15#W -Wll 8 R -1/2"6W5UM 130M ON IN5M. -1/21,rimi9i FLOOR 0\/rp. -0516 @ 6 O.C. FIN15H FLOOR 28 1/2 1724MMI c/) z 130ffOM OF 5TUfm 34 5/8 1879MMI 14 1/4 [362MMI 0 r 38 [965MMI GAS LINE 25 1/4 [642MMI U) ACCESS 21/8 155MMJ -ror or ve 4) .1 1 �> G) F u 21 1/2 [548MMI .i'\A fTICA.WW FOLWATON w -8"IHCK POLIW CONMIt FOLWAfION WALL -T 36 1/8 1916MM3 5A/2"5S L&LY Ca. 08 5/8 1219MM3 2"IHCK I POLM19 COMCIVE ON A 2'-6 2'-6"x I--0" -16"\MM X 6"VEEP POLIT17 CONCITIF FooflKu 11 5/8 [297MM 6 7/8 1174MMI 41 11043MMI "RAT"SLIPS,MIN 16"DFLOW 7 1 %WIM. POLM CONMf M.ITOM (4) #9 PASS EACH WAY, PUFFING A-A W0 z 5CAX:1/4"-I'-0" ) (D 3: MARYLAND m�:e MICHI GAN MISSOURI INDIAN- CONNECTICUT PENNSYLVANIA NORTH CAROL INA NEW HAMPSHIRE RHODE ISLAND NEW JERSEY VIRGINIA mm FLORIDAmemmmmmmmem NEW YORK - C\J [3-13 Lo C\j A-6 c\j 00 0, fop or ma Lu 0 ler -1 r-, w co z > A-A 0 w A-6 00 ce m uj 0 w :-4 Im A-A A-A-'} Lu C, 12 12 12 12 w Ld F- > Lj Z) U) w z Lul —1 FINM aLIN6 0 0 u IX 4� WN19ow FrApaoa aoa w \il tL NEW FMUA55ROOF q w ------__u 51-1!N�B.CaGIZA5 511EMP Py owV. A w IL IL \0 FT1 p Lr) ILIA— A LIU I iL c\j liu I ul -LULLLU JULLi 5f'-ow moor LL IV 11 11 11 1 1112 12 I Hill WIVOW&APFEW. 5EN&E55&UHNUMFKMhV It I LLI ILL JL L L LL i LIL i-L- Lt[j ---It JiLLL- \AM 5RN6 A5 Li 7- - J t Lw 7- a j [ULM - EL Ln lu 11-Lul UAM Lfl 11L IL AL LL ILI- MUILL Eli -111- - —11-Lu I LLIUL 130ffOM OF 5flaEfLM 11A4 1 11 1 J WIN 1211 VA PaMI? CoNmTe PIER,MIN.51-01, 8"VICK POLM7 COKMT mawa\'AM. — —— — — — — — — — — — — —— I MK WA15,MIN.5' —— —— —— —— ————— — MCW CM,5TP VOWN IIJO —— — — —— — ————— —— —— —— —— —— — - — — — — — — — ———— —— —- -- ——— II--I I-T-1 T 5VI`F00flN6190VvN ITI 7 I I F -1 59P 1`001M POWN 4 5EE Mf& I I F- 7 - --- -- -- -- ----- - - -- --- - - L FP,,ONf N,FWAVON 5V VOMN6 POWN 13-p A5fl,'ArE12. A-6 5FF v*,-,!'X1 linn n ml A A-6 A-A co A-4 s)z NEW fiffrZaA55 ROOF 5HINM5,CaOR A5 < 5UM19 PY OWV. + UN (fyplcAl) siz co Q) &1Z NEW ALUMINUM 61MIZ Nv Lrm p.-TYPICAL. 12 5ECONP FLOOIZZ WNPOWMAPHEIatrd,, co z (�\ -71 5MU55 ALUMINUM FKIA5 AN19 MAW TMMVICAJ < r L It ED VIM 51PIN6 A5 N 51 VMR-VPM. -7 — -------- My \-A v FINISH I'Loor d) C) r L30rfoM OF 5TUftM uw) j ✓J I z Fr-- -71 0 _ _ _ _ _ _ _ _ - _ _ _ _ - - < cn L LJ LJ LJ u w5; cAvmrgv NEW 1211 PA PORP AITAWAY.-IYPrmA- KEW IT;t A.rotar CONCITt PIMP,MIN.5'-011 CONCIM FIR,MIN,51-01, M0W(4M,-TYPICAL ILINIMITIN U15TIN6 MoW6m'-1wIc& rom"'Allow wTH F- - - - - - - - - - -- - - - - - - - - - - - - - - - - - 7-01 WIT MIN. 4) FOOTING - - mm moor, Nu 5TP F00flNrA POWN c5 --- ---- - - -- - - - - - - - - - - - --- -- -- - ------- ---- -- -- --------- -- --[- - u Lo L —— — — — — — — — — — —— — — — — —— —— ——— — — — Lu 0 z 51�r rML -) 0 0 PVR, UVAf ION MARYLAND MICHIGAN MISSOURI INDIAN CONNECTICUT PENNSYLVANIA NORTH CAROLINA NEW HAMPSHIRE RHODE ISLAND NEW JERSEY VIRGINIA FLORIDA NEW YORK ♦� � ^ N VO N roP OF ovaN oO VINYL GRALE VENT `.L 1� Nap yy yy WTH IN5vCf SEEN p i� Q 00 ---- IZ - IZ 12 --- 12 d� v 8 �8 8 -- - �8 12 Z 0 -- - 0 cmr CRICKET _ L1J o w W o w -- -- - - — — w Lii - CONTINUOUS 012a VENT,(TYPICAL) ---- - - � u � 0 --_ - FIN15H CEILING _ -- - - - -- _Z 12-- - -- 12 WNnOW NEAP HEIGHT \ �\ w NEW FIDEPGI-A55 POOF - - - - - \ \ IN, UJI W Q 5IINGLE5,COLOR AS -- -- - _ w V -- 5ELECTEn DY OwNEP. _ + - - ,- \ p W - - - (TYPICAL) = -- _�.� - -- - - -- � � � -- - ui -� . - NEW ALUMINUM GUfl[K' -- ------- - / \\ J CL No O No - - ---- --- SECONn'FLOOR ----- — - - -- \ �- ---- -- FINISH CEILING WWOWItAInNEIGNf -r - - -- - 5EAMLE55 ALUMINUM FAC,IA5 AW EAW TRIM,(TYPICAL) -_ - VINYL 51nING A5 - - - __ �LEcr>;n,TYPICAL, — _ FINISH FILOOR - PorfOM OF 5TPIUGM - --- - I I I I I I I I I I I I I I I I I I 8"TMCK P.C.afFK WALL. I -- -- -- - -- - --- - -- -- -- - - - - - -- - - - -- - - - - - -- - -J I I sTERnowNrocEUARFoonNG, �0T3LD ar�� - --- - - - - - - - - - --- - - -- - -- --------- -- - ---- - _ Cam Gu C NEW 12 n1A POIKn 51EP FoonNG nowN COKMTE PUP,MIN,V-01, A51TOUMP. •� mowr4m.TYPICAL SEE nErAIL I 1� __- "'A STEPFOOiINGnONM A5waw. WN I P16Hf 5M �VMON L _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _A5MQJffn. ��Ff 5M � VATION %EMfAIL CEUARfFL°� L- ]---- -- - - - - --- - - --- - - --- - - - - - - 5MMfAILSCGd.PII/���-1� ��� C-- -- - - -- - - - - - -- - - - - - - -- - - - - --- -_ __ _ * � ..- : t` E\� 2"x IZ" CONr,RInGE BEAM _ TOP OF RroG� � 2"X 4"COLLAR S5 @52"O.C. 1/5 1?15fR\a FROM TOP TYPICAL Wa CON5TQY11ON -ASPHALT 5HiINa f5 -15#FELf L.mv 16"OVER -5/8"EXTfMIOM 6MAd7E PLYWOO10 15 2"x 12" CONr.R117a;REAM • TOP Of mix - �, TYPICAL ROOF CONSTRL1CT10N U -2"x 12"ROOF PAFTEM5,16"OC flT'ICAI GEEING CONSiRUC110N `- -2"x 8"RInGE REAM `� 2"X 4"COLLAR fE5 @52"OC, - „ -10,25 DWTf INSILATION,R-38C -2"x 6"CEILING J015T5,16"OC 2 x 6 POOP IWER5 @ I6 O.C. -I/2"GYP, Dn -12"PC[N%LAf]ON,P-56 MAL ROOF CON5TRUCTION I/3 nISfAN�FROM TOP -2"x 8"VALLEY%EEEPER5 -EXTENn ENV5 OF POOP 16"DEYOW 5IVCWALL5 -1/2"GYP.Dn -2"x 12"ROOF RAFTI;R5,12"OC -5/8"EXTERIOR GP.AM PLYWOOD -6 DELOWWItM1VENTEnVINYL 5OFFIf MR, I.OAn PAIN -5/8"EXTERIORGPWn PLYWOOn -15#PELTLAPPEn18"OVEP -15#PELF LIMP 18"OVER A5PNALf S %U5 .l_1__� ICAI,EAW CON5TRUCTION -A5PHALf SHINGLES 12 IZ -EXTENn ENn5 OF ROOF 16"DEYONI7 51MWALL5 v � -1 X 8 CCA W0019 FA50A ROAM -EXMNn ENn5 Of ROOF 16"DEYOW 5IM-WA1-L5 8 F- DELOW WTH WK19 VINYL SOFFIT UNPER, 1.0An PA11-I Z � -ALUMINUM GUr1ER DELOW WTH VENTEn VINYL 5OFFIf WnEP, - -WNTI?VINYL 5OFFIf DELOW. O z - I.OAt7 PATH TYPICAL NEwArnc FLOOR colvsTMucnoN FINISH CLING -11-7/8"fGl FLOOR J0155 @16"O.0 i1/: a�7EP,5EE OAP PATH I -v 4"rG PI-YWn,5cmw&an � � PLAN FOR SIZE TYPICAL CEILING CON5TRLICTION WNnoW liEAl�FEIGHr -I/02'y M Dom WAR, r _ _ ppOpOSNn I I I 1 O -12 x 10"CEILING JOISTS,I6"OC TYPICAL PORCH ROOF CON5TRUC110N 12 DAff INSLLATION,M-38 I I AT11C 5TQM? -1/2"GYP,Dn -2"x 8"PInGE DEAM "x 6"ROOF MAFEMS @ 16"O.C, LOAC1 PAIN 10 -2 PAIN I I I I I I I I -2"x 6"GEEING JOISTS 1 -5/8"EXTEPIOM cim PLYwoon `O °0 "� I.OAP PA111 I I PATH TYPICAL POOP CON5TRUCTION II I I I I O < UN 14 I I I I I I I I I I -15#FELf LAPPEn 18"OVER -2"x 4"Von POOP TAUS`♦s,24"OC I I I I I I I I I I I n5PHA1-r 5HINGLE5 OUMV I I -ASPNALf 5111Na,E5 I II I I II I I II -fXfFW EW5 of ROOF 16"DEYOMP 51PEWALL5 P MAN I I -15#FELrLAPPEn 18"MR DELOW WTH wwr VINYL 5OFFIf umv, 4 IUKt:KI I -5/81,EXTERIOR 6PJU7E PLYwoon I I I I I I I I I I I N -EXSW FW5 OF ROOF 16"PMW 511TWALL I I I I I 5ECoNL7 FLOM DELOW wiN wwr VINYL 50FPIT UNIOER, g- FINI51 I Cl A live - I Ly MR I fli GIRt7EM,%E PLAN FOR SIZE � -_ � -- =— �• PLAN FOR SIZE WNWW&A P HEIGHT POY05N2 pp0P05Pn W L5 I HR FIB PATEn Pf;OPOSCn I I I I l WALLS CO CEILINGS 14 TYPICAL Ex1EPIOP ww L CONSTRUCilory KITCHEN GAP.AG� As PER onE, PAMII.Y f?M I I i I -2 x 6 5Wt95,16"OC WITH(2)TOP I I I I Pp0P05N2 8 &(1)WfTOM FLAT 1 rn (�N fYVMI WV HECK CC N51UWN � I I I I 51/2"DAff INAATION,R-21, _ -(2) 2"X " ATEn MLV 51 L - - -- - m -2"x 6"FLOOR J01 f5,16"oc PO p 1/2 EXTERIOR GRADE PLYWOOD - - - -GALVANIZE TE MITE SNEILn 1:11:11:1 -5/4"PECKINGIWOP05W -TYVEK IA LVING PAPER ;:6 --- -51LL SEALS El El El El Z I I COV,PORCH -VINYL 51nWG -55TD20 AN DOLf,6'O,C _ - - - -11 Q 2"x 8"CONTIN.IXI 2iV LAG PafE12 1 I I I -1/2"0Y1`51JM DOAW ON IN511T. -DPI/8 WA it - TO 51PI M,MINI "OL.5fAGGEffn I 1 I 1 -0516 @ 16"04. n FINI%FLOOR vvyvvyyyyvvy - - _ -- DOfTOM Of 5T1~lrM GIRnEM,SEE 'i a3 I 5LAD FLOOR G PPOP05N9 GIp7EP,5E .:t: , AI- ARAGE 2 7 2 6 (Z) 2"X 6"T'LEA1i M117 SILLI 8"tIiICK P.C.CIivEK WALL. TYPIC PLAN FOq SIZE.{: GALVMIZEn TEP Ln PI AN FOR SIZE- 5TEP VOWN fO CLAR F0011N .. . -4" HICK POLRn CONCREE - - nPOP05� , Q -%L 5EAER x xW.W.F. Z 5LM - 2 55T7320 ANCHOK '51 O.C. TYPICAL FLOOR CONSTRUC110N I -4"GPANLLAM CAMPACTEn MATERIAL 0 . -DPI/8 4YA9fP - ! -11-7/8"fGl FLOOM J015f5,16"OC TYPICAL CONCRETE PITCH 5LAD fO nOOM,MIN 1/8"/Ff. W - C516 @ I6"O C. ( -5/4"TG PLYWV%PFLOOR,5CMWfr2&atfV -4"TWCK POIMn CONCWTE 1 Q PEW 12"PIA Ramon TYPICAL CONCM-Z 5LAa '. _ I -15#FELL -6x6/INO W.W.F. S11 AI LYC , 3-I/2"5S LAL COL, -J CONC IE PIED,MIN.3'-0" -4"THICK POl-n CONCRETE .. :5 > ON A T-6"x 2' "x 1'-O" -1/2"FINISH FLOOM OVER, ON A 2 x O V DELOW aZAI .TYPICAL -dxb/IOxlO W,W F. h'MIGRANILAR CAMPPC919 MAVIAL I POUt�n CO'NCk�TE PAP,oOVInE � � , y POLK12 PAP.PPOVICJE I (4) #5 DABS E WAY. -6�ML VAPOR DARKER - - - - -- - - - - -- '} - - - - - - - - - - - - - - - - �.;' (4) #5 DAMS EACH WAY, a. -4 GRANULAR CAMPACTEn MATER& CELLARFLOOM - - - - - - - - - - - - - - - -- - - - - - - - - - TLL - J TYPICAL NEWFaiNCJATION • J. .• - - -- - -- -8"fHCK POLIT�17 CONCITS FOU VA 110N WALL -16"WIX X 8"PEEP POLM CONCRETE FOOD MRPIN EX15IN6 POOnNG PUI�PM 5�CTION TRO,�EL°NwATE PPP" PULPING 5�CfION W 16"Wt7EPC, Lu F0GflN6 011NGA5PEQUITn. ALA W Q Z MARYLAND MICHIGAN MISSOURI INDIAN CONNECTICUT PENNSYLVANIA INORTH CAROL INA NEW HAMPSHIRE RHODE ISLAND NEW JERSEY VIRGINIA FLORIDA NEW YORK o r` \O N F4 SQUASH BLOCKS & SINGLE RIM JOIST FS FIBERSTRONG 0 F7 BLOCKING PANELS - N °O FI ATTACHMENT AT END BEARING F2 BLOCKING PANEL, EXTERIOR F3 WOOD I BEAM RIM JOIST O r 0 l O USED FOR BRACING F8 BEVEL CUT JOIST F9 BLOCKING PANEL, INTERIOR FIO SQUASH BLOCKS AT INTERIOR BEARING 0 r, cal co Vertcal load knrtsfer=zeoo Of tax Yertial load trorsfer=2aro of max Vertkd load transfer=2800 pl,max RIM BOARD CLOSURE Vertkd load transfer=2aro Of nix slag beortg tab` � � along load 6earig ml based on bearhg p „ e�, Vertical load transfer=M Of max along load beirhg WL Lu O � Q Yertlal toad transfer=4850 Of rr,a AIP6.tlka Ref ar eA.R stress of 390 psi type tarn furor aeaa Ise nrr -�erwt as t,ssr aa, aesra Wred P asn aups�sus as srae aat4 o e K ar e�►a Land a!nst stack over� 1— Z kr(a a apt qn hfoca k+a!kr beam beWA — ar tb not bevel tut Vood I Aeon' &i r °ttraaoo t�ir�( I �Y pip x W � �_ Dx 10d fox or f in V000dral�sNe at rim Joist I 9 rHitrstaus import bloddy ardty or�bean�b over s z v 00 6eorfg Toe-nd rh Jiht to top 2U3?'4BR4 IPA' or Fberst of face aF 1n6 U > per M Vaud I Bea flange of Jrdst tNh llN raU rated dntlhl rim board for doplraan D When J meet over nfl 13/4'aHrn r:ra i.l.a `� Z hag �� beaktg far both ad U Nnd6g pro¢e�t}�d a"a"'a 0 W rvra dM jdstsdsts an crndhus waUlird mtlrad [ifO J mIf liinaJ For sfdrg use Wing►al rdst ahwe. m W O W 6adar block --- - 3/A'elnhn l bearFg ength lid 13/4' 1 _ it aA flow and roof metals nals w O Vw Bd nals yY shenthFg tt aro wen rvaa+aasa Pon a cook Now Void I Aeon'Mocking (L f rhtnJ � To atdd spBttFp Huge,start rots at least 8�d and tt r non&dad ft% a'x-bridglg re Ad rxls at 6•ox for per W Bd Dols at 6'or:far d r r at.de mn:d d per esipit pro,- 8d nals at 6'ac(or per tap me u rs a a.- tt for kternl d° professtnl r o I V?from end]five mots at to ogle to fessimd's sue,hot aplyt�p afth essimol's bmttm Norge � � Bear(tg tab,GP Lan LVL or w.Isom _> prevent TOW^D of"phi l stahation Ibte I,p IC 6�f4aduk:t Wde) &4� �, See detd F7 for Noddrg q*ements t roaplytg dth hshl� Note b,m p W d Product but C 0#9 0 in tiaaBim Dx k Coal hiding rode for appropriate detal h areas of higtt laterd load Grp F1'S�g ed rats it 6'm,center �4Pa Wk a cl � � Note%p.18 G-P Frodxt G O rh board 3-od rats tie-nal to Platte,typkal Ibn stadbg keys re*addtlnal Imianatta � � at Comers Deck has rake oar fir gvott art h arras d Mh filar rka t)ledt focal Wdeg code for appropr(ote detd In areas of 4 lateral load I Lt sbftg tabs r*v addtlmol anddeknt1wL oedk Ind bms Mae far apggarte arts h areas dtomeatr,a � z FI4 STRINGER TO JOIST CONNECTION F15 JOIST TO BEAM CONNECTION FIb JOIST TO BEAM CONNECTION, STEP DOWN FI7 JOIST TO BIFAM CONNECTION, STEP DOWN FI9 SQUASH BLOCKS AT CONCENTRATED LOADS F20 WEB STIFFENERS F2I RAISED RAFTER BEARING 0 ` �& �a Fi2 Ion*ds FAir 3 ode E lI DOUBLE JOIST CONSTRUCTION flangr/kpth the h detds FII,C4!97 Bsr h deeds f13!Fl4 Qbt m(*ed V both boded qdy from above) stiffeners to be a Vertkol lied transfer=2000 Of max I j,I u t 3/4' / 91/r 13/8'(total#tfarssl x 6' 13re'(told iHdoiess)x 6' Cry�LVL Q, (See detd FIB) D� To prevent excrssfre 1-Jdst bevel Cut per detal F8 � � W Bearhg y regtlred at hangers vi6 a D T/8 I are<bttl tht±alss)z 6' 13re(totd ttkimessl z 8' Doable Vaod I fteat�canshtttf�t per decal Fll fiulon Bean OW depth flier).Backer blodd'g she and A„g� APA Rated f—� ~ < z 5/l6'/ 912' 86+are'plytoodrlaA dt;+are'plyaoodNSH A I � U Q D 7/r Bd+are' +3re' InshRatlrn per detal Fla Dearhg ate.Keep plate Note Bea SdFFerers 14' + 'dT+ '� + dTtoodlDse , flush h53de Fnce of beoa may Be q lydsmwthed rafter Q rh a 04 � IL � 2 Y?/ D 7/r 2x6+SM plyaoadre111 2d1+yg plyao-dl�l n LO 14' as+SM piyaoodlBSB 3df+5I8'O)ToodM Tap wMt war s N � from Vacd!Bean �Per� O %, N+5/8'plptmdrl)j11 2d2+Sir ylytomyAiA FAer , 6loddg N 31Z/ U 7/r ow 022 i 14' 0 Zre 0000 V 0 LIS 0 M + Tap notnt ce D &M'i badk of teb duttp n g to prewad domoge to for Gad g Nonler t�Ftbnpe earecilua �pp�oprh ace reqk—ts. 21 Leave LB'pp bettron tap of filer latoddg and bottom of top flange bin eonT hangs sfpayy Ledger for M flak sold beheem Atfor fed leto of spun min mn.r rr Lit a dr be substituted See ontling tttadra nt 4) Nakr Jahts tagethrr trd rot foots code side altlt 2 rats of IOd rots bp�}q 1Hrn Jail Depth Web sllfFemrs d eV : �auk yrrakr. detat F18 far t APA dated Shea ¢T Ica ohm mrentrnted lands eceeed tFe VOILE Lu S all �d at 12'or.dnM diet posit Shgger revs from ippnstte t� • stiffener regiym s Steel BeanIVL or or STIflD I FIIDi h the dart 9 U2' ti2a1 stiles by V. rasums a.xestapeelmsetaraRadH. yidepncyd Gf to TVL or Sogd 6ltuk at pasts from above to bearig betas Instal saffenes per drW FIB but tf#�t egotist B 7/9' 14201 Qkian Bean frith equal tanber of squash blacks ��� �� 14' t50a1 Bd rots at 6'oe(or per desigk pro- w 1500a fessiinat's specs,but nth installatfm Note I,p 18�idluCt G1kJ FOOk &OIST SPACING BELOW PLUMBING WALL @JOIST SPACING BELOW PLUMBING wet to tan Norrload Jkt Specir9 beartg only. ad PUMPING FIXTUPF 5CHN U F Rai 5IlC 712 to wM 49 6 r I o 5YM. t 5mrf oN WA51F WNf=9 HOf W o 6' r NW r 9 n � W.C. WATER i i I V 2 k i t !t. C�U JT 0,05 f ' 1 - r 5� LAV. LAVATORY 2" 1-1/2" 1/2" 1/2" ���EUGi 5 5f*LE55 STEEL 51NK 2" 1-1/2" 1/2" 1/2" 55 5ERVICE5INK 3" 1-112" 3/4" 3/4" 4e v t m T113 Ti13 2" 1-1/2" 1/2" 1/2" Tab `5w 511109P 2" 1-1/2" 1/2" 1/2" above S'T WM' fLECIMC WAVITATER - In I" Jdst fay be shifted tip VI5NWA5fER 2" 1-1/2" 1/2" to 3'to Ava OR* ° FX1511NG t be �XI511NG 6a-t 8adm Interference � k fay �IFkd�h 3 h3 h PEPn 00M PF[12 M ��UM�ING b��"AI�S I PUMPING Not5 I. AU.PLUWN6 WOE'(.f0 BE IN5TAI,I,EV%Bel,BE IN ACC0Rt7N a WfH ff NATIONAL PLUMBING COVE NV Al OTf P APPLICABLE C0VE5 ANV =AfION5.PIAIWING CONTRXf0P 15 fO FILE FOR ALL RfOIBREV PERM15 ANV OKAN ALL RE01,111119 aINFICATES. A. 4f;MAWNGS AW-VVtidMMAIIC AW NOf W NITV f0 ALL ffAM5 OF Tit WORK.H fPLUMi31N6 CON if KTOR 15 fO PROVIVE A C0MPLM ANV C0IUCILY OPERATING PLUMBING SYSTEM. FX1511N(A 13. PLUMBING CONTRACfOf SMALL VERFY POW OF C0NNWCTION fo q"VENTif K011CN PATH v CC) AJV MEVA11ON5 OF EYVIING PIPING PRIOR fO IWALLA110N OF NEW PIPING. - — — ROOF,II-A5 C. PLUMBING CONTRACTOR%U C00WIN[ATf HIS WOW,WITH THAT OF&I-OHR CONTRACTORS KFOW INSTALLATION OF f115 WORK I 1 IN CHA5r5 aLING SPACES ANV OlKP AREAS WIT C0NFLICf5 0 �4511N6 MAYOCCIk. PM —' 2. ALL PIPING STALL PE C.O aALEV.CAPS OR PLUGS%KL 1 NOf PENETRATE FINIS�V SI DACES.COOWINATE TMS WORK WITH 11-1/2' 1-112 I 1-1/21' 0Tf PC0NrRAcM. 1 I I I I �XI511 G FX1511NG —' 3. Fl N5H*V INSTALL&I-PLUMBING FIXM5 COMPI ETf WfH&I, KIZH�N FIfT1NG5 TM AW ACCE550RIf5. q"VENTTl•1:0WH I I LAVATORY 4"ftf iFf�011G>I I a All FIXM5 SHALL BE AMWRICAN 5T A 2AW OR raK,COI OP ROOF.FLA51�V � I WATER ao>rfl I I � N A5>�D I � � A5 5UCTf9 BY 0Ji?JER. ROOF — — I — — — I V'\ �P. INSTALL KWICAP FIXTLM5 W fW 5`19 M ON VKAWNGS. C. INSTALL HOr WATER DATER COM'I-ETE WITH Al 1EMPERAM FLOOR ANV 5AFE1Y CONTROLS,RELIEF N V M NE N VAS,ETC, — — �— — --2 — 4. INSfAU INWff5 W5FM f VEMV RIiy ING BEFORE SEAMING a i CD. I Co. A. 5OL,WA51E ANV VENT PIPING Bfl OWFLOM fO 5'-0"0Uf51VE f' —T BIBLVING 5-OLL BE SfN VARY WEIGHT COATEV CASE IRON 50L PILE XV CASf IRON/WOMW GA`f'.Ef W11N65.P.V.C. I I —T 50fi LE 40 PIPE XV FIfllW5 MAY PE IWALLW ONLY AS I I I I 1-112„ I I APPROVEV BY LOCH.AIMOPITY, I I-I/2" I I I 5.A L PB'ES ANV VA ES.EXPO V AJV CONCEALEV,COVEREV ANV W- 1 1-11 2" I WATER aO5Ef I I LAVATORY I LAVATORY I WATER a05Ef I LAVATORY I LAVAfOR� I �XI511NG COVEN,SHA,L BE MAP.KEV AME IM1H fm N of 11T 5rwa PROWIT I I q„ I F ( GMAT I?M O Aft iM1H AN ARROW IN71CA110N OF ff VIREC110N OF THE Flow, I I I VIA I o m O d.A.L WATER A30VE GRolPv17%U M WW TEMPER,TYPE'L'COPPER FIRST Pt-OOR I — I WAf 1 f 1 z Tf131NG AND ALL WATER PIPING BELOW GR0 W IN51VE 1ff BIAL121% - — — L f 'K' NG P TL13 . L C 2n 9„ Q 2n 2„ 11 2i, I I K'i1131NG STALL CON'oRM t0 ASiM SPECIFICA110N B-88-66A I 2 'tn 2° OVO-5EV C0NNECil0N5 TO PLUMBING FIXM5 ANV SPECIAL 9" CA. C CJ. EQUIPMEW%&I,BE CfROMIUM PLAZI9. ftlIN65 FOR(TOPPER fLVING 5111A,L BE 150 P.5.1.CASf ITV BRASS OR WROIfGfif COPPER SOLVER TM FIfTM5. 411 4" W 7. 1?0ME5TIC COLV WATER EXP05W f0 FREEZING AW 170ME5fIC HL WATER,V0ME5fIC HOf WATER STALL BE MAIEV WITH OW(1) INCH TO SAMfPR1 CA. � Q N0MM&1fICK FIBERCLA55. SYSTEM 9"CAST IRON MAIN HOI EE MN, 8.U NORIZONf&PIPING SNAU.BE 5U'P0RTE19 BY MJ115TVLE It" 1 O MAVEV ROV ft UP5. M46M MUSf It OF A M%N WNICH WiLL z PERMIT VERTICAL AO-MfwMf aF PIPES. Z • _O 9.AI L PIPE PASSING ITH 5, N WALLS,FLOOR PAPiftI0 T O( CEILINGS aA�frlENf — — /`I 5�'I N� Q > SNALL BE FIfTEV W1M 5-fEVES. SLEEVES�IW.I,BE TWO C 2) SQEV Lmaiz1WWPIPEWF'ENWISLATEVw1T rNwm. �XI5�"ING u W ly- I O.A-L PIPING 51-N-L BE PROPERLY 6MV FOR 19PAIWE OF SYSTEMS, C�/ V\ F�OO F PUN p�UM131% PIAGpA FRY FL00� P�AN 11. � APOL 5=a5 KI,K TEai V&VeP LLW555 Feu 1�n A5 PARf Of FTXfLM rlf11N65. N0f TO SCALD 12.Al LAVAf0RIE5 N7 5INK5 fO HAVE SINGLE WVV LEVER"VELTN' FA1.I15 AVV TRIM,A5 SELfCTEV BY OWNER. &L 9VMV 5 N\V BAHL05 SNALL NAVE:%ae COOT a FIfTiNGS WITH COMMON WONG VW M PM55H BA-ANCE FITTING. w Z QO � C� � N MARYLAND w=IMICHIGAN MISSOURI INDIANA CONNECTICUT PENNSYLVANIA NORTH CAROLINA NEW HAMPSHIRE RHODE ISLAND NEW JERSEY VIRGINIA FLORIDA NEW YORK It It N 1PJ3M 3,1 �/CHUNG J015f Ill, JOINt CONNECI1ONQUIiMN5 1 1i�t31 5,3A WSp/ aLING J015f T fOP PUAS UASk&ANn WOOL? MAMl RI 1 CON51ION MANUAL C 1995 513C HIGH WINP EVION) I® LO N CO N I FGV 20 P5F k00F LK Lov 5HM CONWUON MQUIP M�N15 �"A13L� 3,1 NAILING SCN�nUI� -- � � t Lij � � N (PM5Ct?If'iiIVE ALIEE 9 TO TABLE 33) 4 JOINT M5CRI"ON NUMBER OF NAM5 NAL SPACING — r �D O ROOF TAN(Ff) Fffif5f MILE WW TEED(MMFN) ROOF FEAM!NG 11 ` H `��+ Z` Of 00 12 20 28 36 110 EAFIER TO fOF PLATE (SEE fADLE 5.M PER R/ R , i I�S ,�� �'sy �yd R SPACING REQUMED NWMBER OF 16D COMMON NAL5 PEE f WALL NUWEM of 8D COMMON NAL5(TOEWJLED) CEILING JOIST TO TOP PLATE<f0E WVLED) (SEE TABLE 33AJ PER J015f I i i tl `ri • O W RAFfEKS.oi'E MPFTE EAFTER/CELINGJ015 � Z (IN.) I'm JOINT CONFECTION.l,2),3,4,5 5FACIN6(114.) I'EIGMf(m m; Usmr W EACH RAFTER AW/OR all-M J015T TO TOP PLAiE CONNEC11ON i.z3 CEILING JOi5f f0 PARALLEL WM(FACE NAILED) 5`E TADLE 3.7) EACH LAP r � � O CEILING J015f LAP5 oVEE Fmnf1oN5(FALE-NAI,ED) 5EE TADLE 3.7) EACH LAP bra i 0 12 4 6 8 II 8-10 3 COLLAR iE TO RARER(PALE-HALED) 5:E TAM 3.4) PER iiE � r i� Ye m 16 5 8 II 14 IZ BLOCKINGfORAPiER(T 4PLED) 2-8D EACHEW � � `I C7 ��' • 51mp5on strong-fie W O W 3:12 24 7 II 16 21 I6 8 3 RIM DOARr7 t0 RAFTEE(Erin-W10.Ev> 2-Ibn EPLN ENCJ 1� ��i Slm 501'I 5tl" �fle I-SrA36 Strap ° ° � _ o 10 3 WALL FRAMING ' �� i p 51mp5on 5traq-fie ° W O � 12 3 5 6 8 24 8 4 1 ,,, f'NC72-51733 r1 KInGr, CONNrCTION nr1Al, r532-24 ° I6 4 6 8 it 10 5 t 4:12 7.4 5 9 12 16 TOP PLATE TO TOP PLATE(FACE-NALF17) 2-16P l PER FOOT )'hl i I , �l HW-- I.IOD BOX NAL5 SILL BE FEP.MFfTED fO BE 5t351n=I' M 8D COMMON NAIL5, TOP PLATES Af INfEMSECfION5(FACE-iaW) 4-16D JOINf5-EACH 511T l� _ j 2,WEN CELING J015T5 M WSfALI.EP FARA 191-TO?A-MR5,IfE 5UM OF TfE TOENAL5 IN if,,PARER AND 511V f0 5AV(FALE-NAILED) 2-16D 24"O.C. - y1` .,• o ® O 12 3 4 5 7 CELNG J015f SNAIL EQf1Al OR EXCEED 1fE fA3lLAtED NUMBER OF NAILS REQUMED. WA7ER fO WA7ER(FACE-W LEn) 16n 16"O.C.ALONG FM5 J\h r e j z (n 16 3 5 7 9 3.fO AVOID 51WIN6,NO MOM THAN 2 f0fM5 5W.1-BE INSTALLED IN EACH 51DE WHEN PA51UM17 TO A � � � ••{'' ,:�' `�'� � � 5:12 24 4 7 10 13 2X6 TOP PLATE, TOP OR BOTTOM FLATS f0 511 t7(E W-NAI.ED) 2-i6D PER ZX4 511d7 0 0 2-16D PEE 2X6 5IW I/; Sampson Strarq Tie ? Z 216D PER 2X8 5Ttd7 , 5tardard 5tranq Shear Wall O J 12 3 3 4 5 Simpson strong Tie r lI ,. O 16 3 4 5 6 t ' ' 7:IZ 29 3 5 7 9 BOf10M PLATE TO FLOOP J015f,P*VJ015f,EW 2A6191,2 PER FOOT pHf72-51?33 , a b • ° U JOIST OM BLCXKIJG(PALE NAS En) J P,..•.• MIN.Iz"rrn. I� W Q COf?N�1 CL ING n�rAIL �"�"�` Uj U 12 3 3 3 4 TAM 3361"Orf 511 P COWC110N MQUiITMCNTS � � - I6 3 3 4 5 C f;00�-TO-WPLI, WAI.i,-10-WADI. ANf7 WN.i,-10-�OUNI7A�10N) _ �, 16 N 5hnp5on Strorq-fle o U FLOOR FRAMING •• 9:12 24 3 4 6 7 ,4. : 4, WI OWS PdJD GAPAGE DOORS LOCATED Mf520 °O o° = Q 11 (PRESC�IPIIVE A-iERW1E To TPfA.E 33) JOISTTO 5,L,TOP PLATE OR(41TER(fa-NMLED) 4-8n PEE JOIST WITHIN 48"OF A COW%I&L M C3RACED � U _1 BRIDGING TO JOIST(f0E-NAILED) 2-en EACH END WTH 51,0NG-WALL PANEL A5 REQUIRED, W 12 3 3 3 3 DLOCYJNG fO J015f(fOE-NAUP) 2-617 EACH ENn 5EE MA 391NI5 5HEEf FOR OPTIONAL 16 3 3 3 4 MOCYJNG fO SILL OR fOP PLATE(TOE-NAI,ED) 3-16D EACH BLo� 5H�A�WN.L H X191?o N CORNER BRACING, J015f/k*1EIZ/ F' At WOOn TrU55 L" 12:12 24 3 3 4 6 rMTE5 MILE WWD 5'EED(MPH) LEER 5fW fO f%EAM(FACE-WLED) 3-I ion EACH J015f CONN�C I ION n��AJI. N J015f ON LEDGER fO BEAM ME-NAILED) 3 8D PER Jol5T CONN�ClON n�1'AJL 5t'AC�t;(3pAC�p b�1 AJL 110 PAW J015f TO J015f(END-NALED) 3-I6D MR J015f 1,NALWG MQUREMENr55'Jd.!-t3E PERMITTED TO BE W E5 25%( Ir W L5 AME CL-INDW. BAW J015f fO SILL OR TOP FLATE(10E-NAILEn) 2-16P i PER Foor C Z 51 OKY 511;UCTU ) 2.IEEE JONf CONNECTIONS PRr NOf REQLL�D WREN iFE RIM Is%MORfED BY AA LOADBEA MW WALL.[CAMP OR RIDGE BEAM ROOF FIfCH ROOF SPAN MEQUEED NUMBER OF 8D COMMON NAILS W I� 3.NMN M MEDATE%TORE Or 1K RA IZ I5 PROM t7 BY VEWAL 5TU5 OW RaIN5 f0 A LOADBEA RING WALL,ffE (Ff) EACH EW OF I-1/4"20 GAGE 5TRAP L2 EOOF 5F01-I NG fA31LAiED{•EEL JOIW CONJ.CiiON MMMEW5%U.BE MRMirTEn fO BE InR CED PROPORTIONALLY TO it E REDUCTION 12 3 W 5'AN, 16 3 5fUTIM PANEL5 8D (5FE MU 38) 4.EOWA.ENTNA'LWG PAffEr3J5 PRE WOUMED FOR CELING J015f TO CELING J015Tf LAP 5'LICE5. 20 3 DVGONA-B0AW 51PAiHING 5.MLATED HEEL JOINT CONFECTION ITQLM095 A55t1ME CEILING JOISTS OF E'A W TE5 ARE LOCATED Af 1W BOTTOM OF z'.4" OW aus Ln�zoL 12 24 4 I"x 6"OR I"x 8" 2-817 MR SLI'POEr Use even{other Hall hoc Q rw�cw.nrG"oc. TrE AM SPACE,W fN CELWG J015T5 OR RAFTER ilE5 ARE LOCATED WU W THIS AM 5'ALE,NO AM% Wa 15 A55UMEn, Z8 4 I"110"OM WDEE 3 8D PEE SLPPORf In a roc to provide he iN NI °° ° ° ° w z ��'� t��c>bwG uo 51 AW ffE TABULATED FEEL JOINT CONNECTION MEMMENf551MI,BE INL�ATfn VYf}E FOLLONMII F/,GTOR5: 32 5 ° ° 31/8 MIN- ° <2)IonNaz code-required minbrum „ w 36 5 CEILING 5MI-11 G 12 815/16 MAX ° ° ° Oeo ML5 IZ 3 center-to-cerrter - 16 4 bYP5UMWA-LI30ARD 5D COOLERS 7"EDGE/ 10"FI1`.LD spacblq for Halls w �- CEILING wilafff/ROOF ma TESL JOINT CONNECTION 20 4 I Skiff(Hc/f4r) ADJUSTMENT FACTORS 16 24 5 WALL SEAiHNG WI 5D COMU NM. —';; , - 6 (19/16 MIN-5 5/16 MAX) a la'O.C. 25 5/6 32 6 5METLRPL PAAEL5 8D (SEE TABLE 5 9) � z^,�'w ocK Nna en rO 4/5 6.00 / SIMPSON® EP6I BkP�IMMA Iq7 NNLS 5.00 7 I'MMOARDFftI,5 Strong-fie GW`%M00AV 3/4 4.00 12 4 7/16" 6D 3 3"EDGE/6"FEILD aE 3 2/3 5.00 16 4 25/32" �13 3"EDGE/ 6"FIEILD SPAN NU 51 strong fie NUS 5ncoal.e.C. 1/2 1150 20 5 GYPSUM W 1,130AW 5DCOOLER5 7"Mir/ 10"FrU? 1/4 1.55 19,2 24 6 HAMAW 8V (5EE fABI E 59) / nOUC3L� 51 I�Ap OW WA,L 5nm 1/4 5 1.29 5z 1 PMICLEL30AW PMU5 8D (5E TABLE 59) JOIST HANG�r?I7�rAll. IbL i o 1.11 36 B IZ �i3�ING GA6Ll INI2 WA-1 C C5201 nlA�a 1A DOP(T SEAi 11 / 12 5 „ n " n 2-8D PER SUPPOMf - I xb ORI x8 16 5 I"x 10"OM WDEM 5-W 20 6 PER SU>PORf Q -J' \rah E f D ETC, 28 8 Provide mininum 1211 1 P13(.�3.8�00F SIAtHING Aft ACHMEN1 CQUIM�N1 1%Of;WINn I,OAt75 24 24 7 FLOOR 5EAIWNG 32 - end distance �ti t a `rti STRIICILRA.PMELS $ 36 I"ORLE55 8D 6"E196 / 12"FIELD CAMI I/4"x20 m FASTEST MILE IMND7 5'EED(MPIi) I TfE TPt3U A1ED KEQURENENfS A55UA4E A E00F/GEEING DEAD LOAD OF 10 F5F<2/3 X 15 P5). GREATER if1AN I" IOD 6"EDGE/6"FEELn Equal raamber of o G 5fWIN n r I E A GEEING A55EA1BI Y IS NOf P�SENf OR E iI E GEEING A`f,EMBLY IS NOf CONFECIOD TO I7K0,A-BOAW 5EAi}6NG specified nad5rl v IIO 1}E ROOF A55EMDLY,VIE fA31LATED NUMBER OF NAL5%U.f3E INCREATD BY I WL Af E"Eta I"x 6"OR I"x 8" 2-8D PER SUPPORT I I/4"z 20 JALI STLCGS 51131C11 k'/1 OF 4E 57M, FOR EACH 5 P5 INCREASE W 5TMUCfIPA ROOF/CEILING MV LOAD,11f fMLAfEn I"110"OR WIMP 3-8D PER 5UPPORf In each end (a pl,� FILL LENGTH z �rs,, Y - ,'105 5 A1HNG NUMBER CIF W1L5 MALL BE FERMff1ED TO Bf RERM f3Y I NAIL. COL SfEAfiING 5i1d75 2 FOR WAU,-TO-WALL AW WAU.T0-FOLMA16N CONNEC110N5,1FE fWASI?"MAR OF NAL5 I,NALWG MQU�MENf5 PRE BASED ON WALL%UATWNG NALEn 6 INCW5 ON-C WP ATi}1E PANEL EnLz, E WALL SEAiNIIING E F 51ALL f3E M Wr1ED fO BE REM17 BY I W Af EACH EW OF 1fE 5fM FOR EA01 FU.L WALL P80VE. 6 NAILED 3 INCf 5 ON-CENiER Af IFS PANEL EDGE TO OBTAIN H 6KR 5EAR CAPACIIE5,NALING REMIREW105 FOR 51PJ1 fUj,,. ; 51mprom 5tronq-TIe (2) 2yb U'TO 1'-0" 5EAIHING EPFiER/11�55 5'PLPJG MAXJMllM NAIL 5'KLWG FOR 8D COMMON NAL5 MEMPN 5 SHALT.BE 170=17,OR ALTERNATE CLKJPECfOMS,SUCH A5 SEAR PLATES,SiALI BE 115ED TO MhNfAN 11 E LOf� �:„( C516 Coiled Strap (���(�A1ER e5 EACH SILL '. <. '. •. � 2.WH:N WALL 5 FAI iM 15 CONIINUOLS OVER CONNECTED AMEWR5,ifE 1f131LA1En NUMBER OF NAL5%U BE FEWTED,0'{ LOCATION I (INCfE5,OCJ (INa5,O.CJ REDUCED fO 1-16n NAIL PER FOOT, 12 6 12 z �% 1-I/4"x 20 z 4'MRiAMMIZEWGr ZONE 16 6 6 GA1Y�E COIL Simpson 5Lraq-fie 5bnp5on 51,onq-fle 51m son 5tronq-Tle 19.2 6 6 s tA1 F 3A t??a SN51ON 5WP CONWC110N ITQURTWNt5 FLOOR 11�ANCHOR 5TP IKU AC4 p N 24 6 s 6 1AI31.�3,2A 511,1.Ot;(30f1 OM pi.A1�TO FOUNi7A110N ANCNOt;1301,1 CONNECTIONS I ALIT snn MLE41N �� Simpson Strona-Tle 12 6 12 M51511NG I,AT�M ANn 51fAR LOAn5 10 CONN�C110N n�1 AIL � _ r05T/ 002n P, / H�AMP,COftC110N P�f& LsrA�21 IMEMOR ZONE 16 6 122 19.2 6 12 z TENNO'' (PRE5CWflVE ALi RNAT fO MU 3.2) 8 z 24 6 6 ( FA51E5 MILE IMW.51'EED(M GADI E ENDIVA L FAKE GR EPKE 1RI55 4 4 7m, ilo I/2"ANCNOp f30L 15 a/8" ANCFiOp f301,T5 s R TWA ROOF PITCH ROOF SPAN EcC�D NUMBER IT 8D COMM014 NAL5 IN FA51E5f MILE PAW 9IM12(MPH) FA51E5f MILE WND 5PEED(MPH) t7EfAL5 1� 0� (FT) EAa1WOF1-1/4"20Wa5TrR1,2,3,4 9 H�Af��p��AMINGn�rAl� a 51mp5on5b-aiq-fie 12 4 110 110 PND2-5D55 5 EAi 6 EAFTEM/1RI55 5'ACWG MINIMUM NUMBER Of 8f1 COMMON W L5 ` ` 5fZE (WCfE5,O.CJ PER 5PPORf 16 5 ANCHOR BOLE FOLNVA11ON BRACNG WALL MOWER MAXIMUM ANO•IOR B01-f MNJMUTA ANGf10R BOLT ® o � \ \ \ co 20 6 lib OR IXB SfATWN'.4 12-19.2 2 3:12 24 7 CONFECTION 5U'FOK'f1NG EDGE NAIL 5'ALING(IN.) SAPLING(IN,) SPACING<INJ I r')OE LARGER 5li AiI ING I2-19.2 3 28 8 15fORY 46 92 o V 32 - sp l PLAITS t0 FOUJDAtION 2 5TORY ALL r 23 46 E-NAIL SPPCIJG AT FAFEL EDGES C INJ 36 - (CRAV&5PACE OR BASEMENT) 3 SfL>RY 15 73 : e 51 5on 5traq-fie F-NAIL 5PPCRJG Af INTERMEDIATE%MOEr5 IN iH'PML FUP(INJ 12 5 z impson StraTq-fie CNW 16 4 3 2 19 :B z . N o PIiD2-5D55 O WALL WHOM PLATE TO FOUWAfiON I.FOR ROOF 51•EAfliM W 1124 4 FEEf OF PERIMETER EDGE OF ifE ROOF,WCLLVWd i 4 FEET ON EACH 519E OF IM ROOF PEAK, 20 5 I-3 STORIES iK 4 FOOT PERIMETER EWa ZONE Af9CHMEWREOMEMr EW55 54A,L BE USD,r• 4:12 24 5 (5Lv ON GRADE) • — 2.fABUIM 12 INCH O.C.WL SPACING A55LIME5 5EAiHN6 AffALfED fO tU�PWl i 155 FRAMkING MENMR5 MI G>0.49. 2B 6 � � � z Q - 6 s 36 51 e Q V \ FOR FRAMING MEMBERS M!0.42<G<0.49,4E NAL 5'ACWGS 51A-L f3E R RU17 fO 6 INCK5 O.C. 32 7 • -.fHB"ZV 6 NCH O C,WL 5'PCWG A55LP95 9-VIHNG AfTKW 17 TO RAPIERY 19W FRAMING ACM 15 WiTH G>0.49. 36 8 FOR FRAMING MrEN�R5 MI 0.42<G(0.49,11E NAL TKWG5 SHALL f3E�EITI.ICED TO 4 INQ•E5 O.C. 12 2 A\CIIOMAGE REMP f0 RE51%LAi�PJV.LOA75 5KL BE DETERMINED IN fit FOLWDAION M516N PER 5EC11ON 1.1.4. r,+. • f . 4,THBLLATED 4 INCH OC.NAIL 5'ALING A551ME5 SHEAffINI A17PCi ED TO F.AFTEE�/iR155 FRAMING MEMBER5 WITH G>0.49. C1K Alva 4 MEMBERS WI1N 0,42<G<0.49,riE NAIL Aff ACI S SMAI L BE R DIKED TO 3 INCfES O.C. I6 3 I ANCHOR BOLT 5PACING5 BASED ON MAMOMIIM SEAR CAPACITY OF LMOC P ROOF AW/OM FLOOM DIAPI K'AAMS<219 t4 iF>. ;,;... . ,• F 20 4 zANOTOM BOLT SPAGIJGS BASED ON MAXIMUM SEAR CAPALIfyof BRACING WAU,M2METEP EDCB NW 5PAGWG OF 3"O.G.(151 PLF)BUILT W ALCOWN\a WfH 5:12 24 4 5EC11ON 5.4.4. 28 5 3ANCHOR BOLE 5FACING5 MEV ON MAXIMUM SEAR CAPACIV OF BMPCWG WAU-PERI,ViEtER EDGE MAL 5PAC.ING OF 6"O.C,(421 PI.P)SULT IN ACCORDMICE WITH '!<<: 32 5 �CfION 3.4.4. COpNI;p 5TU17/5Hr, "NA1 COftF 51'Un/5H�AC;W&L Z �_ 6 slmpson5traq-fie HOLnnOWN CONN�C110N 19 1f L HaPPOWN XftC110N 12 Tf& C516 COILED 5TM n TAI3r,�3,9 WAI.I. SN�AMING ATTPCHM�N1 QUI M�NttS FOt; 1b 3 1A L� 3,X 511.L R POffOM PLAt TO FOUN7A110N ANCHOR BOLT CONWC110N5 C51 COW s ITM M2I,OAt75 20 3 51511NG LIF1 511.1. & Cf?IPPL� / FOUNPA110N 5LU & P\0PON / rOUNPA110N 6:12 24 4 3'-0"MIN.(251Y51k11G11.�5) 11 FA5T5f-MII,E IMW 5'f-En(MPH) 28 4 (FME5CM9'iIVE ALTERNATE TO MOLE 3.2) n CONN�C�10N n�TAll. CONN�C110N n�1'All. 12"MIN,FROM cOM3 6-3/e 32 5 6 36 6 6' "M N.110M LMK 15 5) \^ 110 11 12 2 6' EN7 ZOW 5 It TE�IR ZONES 5/8"DIA 16 3 — — — — - 20 3 FA51E5f MILE WIW 5>EED(MPH) Fh`fE5f►NEE WNP SPEED(MPH) (MI NOR BOLT � MINIMUM EDGE 7:12-12:12 24 4 (MIN,I6-5/8 DISTANCE 9 E F 28 4 EMI3EDMENf) \ 5-AiHM 51LD SPALWG MPJQMIIM NAM.5PArCING FOR 8D COMMON NAL5 32 5 IiO IIO 5 ANCHOR BOLT FOWDATiON MAXIMUM ANCHOR i3af MWXIMUTA MUM L3af � O LOCATION, <INCFES,O.C,) (WC}ES,OCJ � FH72-5D33 m CONNECTION SPFOMIING SPACING(INJ 5PACWG(INJ #4DAR , 4• coRNGR MIOLVOwN \ COLT �� ,r.; . Z � 12 6 12 i.fABILATED C0N EC110N REQUMEMENfS A 3ASED ON fOrA U'LEf MINUS 2/3 OF tfE ROOF ASSEMBLY IAMETER a 16 Aria 2Doa r Q 4 FOOT EDGE ZONE 16 6 12 Y4 6 12 z DEAD LOPD(215 X 10 P50. 5LL FLAKE fO FOMA11ON 1-3%OM1E5 72 12IJ 2,WH N 1fE TPBILATED NLWIBEM OF NAll 5 RiQUMED W EPLH E W OF STRAP 15 EQUAL f0 I AW 1}E FRAMING C CRAWI SPACE OR B/SEMENO 8"FG" 15 AffAQ•ED IN ACCOMM IGE WfH TABLE 3.14E RIDGE 51P P M ADDITIONAL MM 15 NOf MQUIMED, 551i32() T' * : = z z 12 6 12 3.WEN AGOLLAR TE 15 USED IN LEU OF A MDGE 5TRA>,4E NUMBER OF IOD COMMON M5 MQUMED IN � #4 WPM 16 6 12 EACH EW OF IfE COLLAR 1E NEED NOrEYaW THE fAMATW NUMBER OF SD NAL5 N A 51EEL 5T W. WALL BOTTOM FLAS TO FOUWATiON 1-5%0RIE5 28 6 . � '•' N - N WORM 14 6 12 z 4,tABU A1ED LOFrELfioN REQUEEMENfS A�8A5ED ON A 12"RIDGE STRAP SPACING,FOP DIFFEEENr E1DGE MAo ON GRADE) ANCHOR POLE PLAN, R—MIDCL 5fM 5PACWG5,MLI TIPLYflf fAnASP VA Jf5 BYPPPROPRIATE MfLMER BELOW,E iM NUMBER { "3� a +:y'r •. Cf�W�rIICA, E:I/2" I-0" ~ Of NAL5 IN FPO VIM STRAP EXLEED5 8,SPECIAL CONFECTION HARDWARE 15 REQUIRED, L V L FASTENING SCHEDULE ,;'s � o DOPRID SEAiHWGi OM 5,fMAiMD LENGTH ITM MEW5 A55 K A MEAN POOF� IWI`OF 33 FEET.FOR MEAN FEIQ•If5 OF 15 :. 2"MI MUM Simpson strong-fie ,. LAP SDING FEET OR LE55,ffE MLATED VA AE5 5 I,BE PEEMIr1ED TO BE Mll.i1PLEn BY 0.60. a. 51MCMR f3P7/8 A n,..a dp°. , A (Nails)6 F(Screws) I�TE$r .:w� �0 5EA1}i EAFIER/TRIl%9WIFI MINIMJM NUMBER Or 8D COMMON NAILS E ad.. A 519E (INCfE5,o.C,) MR WOEf Iva wnvs oc L Confirm adequacy of the bean(depth and number of pieces)for earrop the designated load :q[�4' Simpson 5tronq-fie RIDGE STRAP 5PPLIJ'+C IN.) 12 16 19 2 24 28 72 �•a 2. Stress level for nall and bolt values Is 1007 Increases of 157.for sm loaded or 25% 55Ti320 Z I rb OR IX8 5fEA4flNG 12-24 2 ►`—'1 for man snow loaded roof conditions are permitted. 51mp5on 5Vonq-fie MU-16'LIER I.00 133 I.60 2.00 4.00 6, 3,.Top and bottom row of connectors should be 2'from edge, MU4�} i ' �j r�/� r FASTENER AJD CONNECTOR NOTES: O IdO OM LA'.GER 5EATHING 12-24 3 4, Bolt holes are to be the sane diameter as the bolt,Every bolt must extend trough G n �I ANCHOR PCt I J (n E-Nat 5>ALWGAfPP�LI EDCLS(INJ B (Naas) the full thickness of the member.Use washers under head and nurt POST' I OUNVAI10N G �I r�G p� 1,FA5TENER5 FOR PRE55UV' IM519VAlIVI AW Flf�-i�TARDANf-MATEn iHRM MS IF LLG 5, For three-piece member,specified nailing Is from the each side. CONNLC I ION V l-TNL W0017 SNAIL DE A MINIMUM OF NOf-i71PPEl?6ALVANIZEt2 5TEEL,5fAIN,E55 U � W F-NAIL 5PPONG Af MizJAEDIME 5PPORf5 N 4E FA,EL FELD(IN.) Ir 6, To nMze rotation,four-piece members should only be used when loads are anAled r', C0ftC110N 17�1'AII. 2 51EEL,51LICON BRONZE OM (n LL' to both sides,or completely across the top of the member. 7. Four•-piece members must be bolted or attached with 6'screws from both side.. COPPER.EXCEPTION:ONE-HALF INCH PIAMETER OR QTATER 5trl,BOLTS, i.FOR WAI L 5EA49NG MEN 4 FEET OF iFE CO"M.ifE 4 F00f EDGE ZOFE A1rTAGiMENf REQUREMENfS SiAI L BC U5 D, F & Floor Joists must be attached with approved metal hangers. ONE 5fORY 5flZUCM5: 2,fVLLAiW 12"O.C.NAL 5'ACING A551ME5 5EATi�YNG AffAC&P fO 5iU7 FRAMMWG ME ER5 G>or-0.49.FOR FRAMING C (Bolts) L E(Screws) 9, Screws ore USP VS series or Simpson Strong-Tie SDS Installed per narufacturm instructions. 2.IN 111E COASTAL NIGH WM AREA AND 11E OCEAN WIZARD AREA,ALL MEMBERS WM 0.42(a-G<0.49,Tit WL 5PACIY45 5•W.L f3E PERM?T(0 6 INGf 5 O.C. rvo Revs 24 Dt aC SrAGGM 10.Screws for 3-ply and 4-Ay members must be from both sides of(bean 5PACE 5/8"D1A,(301, 5 6'-0"O.0• 3.POP WERIOE PANEL 5i9ING,GA-VANrZrn BOX NAL5 5NLL 13E�ERM TV To BIE 9V5 IWP FOR COMMON W L5. WIT FROM CORNER5 V M MIN.2"5QU 9 Wk9a5• METAL IZE19%T0M5 AND I'MOCrAZIN MS N M12E OF COMMONS,5TO SMALL t3E HOf HIP z4'ow; 0° 1 3/4' Multiple Piles 1 3/4' + 3 ll2' 3 1/2' GALVANIZED STEEL AFTER FAI3RICA110N AND MEET ASfM P153. EXPOSED META,GONNECfORS, Qo Q 2 PLY 3 PLY 4 PLY 4 PLY 2 PLY 3 PLY 2 PLY N01�; TWO 5f0RY 51RUCM5: as carareedomi as ear.rectlaa ae Cw"Ctloro ue C«neetlon) rz�Cor.rrdw ar Cwnrctlaa aE Corw ecaan) SPACE 5/8"DIA l30Lf5 5' O"O.C. SUCH A511E-DOWN STRPT'S ON PORCHES,DECKS AND AREAS UNDER THE STRUCTUPE SHALL[3E D(Bolts)6 F (Screws) A,LL 511'MPING fO M 16" O,C,, A�1D 12"FROM CORNERS WITH MIN,7--"SQUAB WASHERS, A MINIMUM OF 5/16 INCH THICK AND 6E HOf DIP GALVANIZED AFTER FA3RICA1I0N AND �, rvo Rays Ir im MEET A5fM A25 AND A5TM A55,%*LE55 5ftlL UGNf-GAGE METAL CONNECI'OR5% L ® o © EEH EACH ZTMI;EACH 5TUR M. t3E PERMITTED IN EXPOSED OR PARTIALLY EXPOSED LOCATIONS,MI f&CONNECfOR5 OF W O � Z ® >z oco ® /ED Pn A L ANCHOR NUT�MUSfEU'E NSfPLLED A'PROVW EQUIVALENT CORRO50N RE515TANr MATERIAL MAY f3E ACCEPTED, S AND T1GNIENED FOR fm rRAMING IN5PEC110N. EL p MARYLAND MICHIGAN MISSOURI INDIANA CONNECTICUT PENNSYLVANIA NORTH CAROLINAammummilnIrmn NEW HAMPSHIRE RHODE ISLAND NEW JERSEY VIRGINIA FLORIDA NEW YORK