Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
32523-Z
FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-32994 Date: 04/21/08 THIS CERTIFIES that the building ADDITIONS/ALTERATIONS Location of Property: 345 DOUGLASS ST ORIENT (HOUSE NO.) (STREET) (HAMLET) County Tax Map No. 473889 Section 26 Block 3 Lot 3 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated SEPTEMBER 27, 2006 pursuant to which Building Permit No. 32523-Z dated NOVEMBER 29, 2006 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is FIRST & SECOND STORY ADDITIONS & ALTERATIONS TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR. The certificate is issued to NINA S. ESHOO (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A ELECTRICAL CERTIFICATE NO. 3063061 04/04/08 PLUMBERS CERTIFICATION DATED 03/26/08 CUTCHOGUE EAST PLUMB&HEAT i Au t /Zed Aignaeure Rev. 1/81 Form No. 6 TOWN OF SOUTHOLD BUILDING DEPARTMENT' NCJ TOWN HALL' C o 765-1802 �l APPLICATION FOR:CERTIFICATE. OF OCCUPANCY �i 5 3 A. Thisapplication must be filled in by typewriter OR ink and submitted to� the building inspector with the following: for new building or new use: 1. Final survey- of .property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval -from Health Dept. of water supply and sewerage-disposal(S-9 form) . 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. _ 5. Commercial building, industrial building, multiple residence -and msz llatr N,40�,; and installations, a certificate of Code Complianoe from arch'i e��t-.or engineers �� 1 responsible for .the building. �` ` •,.ti i ;, i, 6. • Submit Planning Board Approval of completed site plan requirements.,,DR 11`41 i., B. For existing buildings (prior to April 9, 1957) non-conforming uses_,_._or buildings and "pre-existing" land .uses: = „-- 1. Accurate surveyof property showing all property lines, street-s--=liu`i1-di d P P Y g P P Y � g unusual natural or topographic features. 2. A properly completed application and a consent to inspect signed by the applicant. If a Certif icate .of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00, Swimming pool $25.00, Accessory_ building $25.00, . Additions to accessory building $25.U0. Businesses $50.00. 2. Certificate 'of Occupancy on Pre-existing Buildine - $100.00 3. Copy of Certificate'of Occupancy 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 Date . . . .!i .�< . P.P O. . . .. . . . . . . . . . .. . . . . . . . . New Construction. . ..... .. .. Old Or Pre-existing Building. .,,.. . . .. . . . . . . Location of Property....13.�.�... ........ .. . .s���1 �. ..%t4/. . . ... . . . .. . . . . . . . . . . House No. �� Street Hamlet Onwer or Owners of Property.. . .4a.. �.,, 7-/ av . .. .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. County Tax Map No 1000, Section. ... .9':K:. . . ..Block. . . . . . . . . . . . . .Lot. . . . . . .. . . . . . . . . . . . . Subdivision..... ... .. .. .. . . .. . . .. .... . . ... . . .. . .Filed Map. . . . . . . . . . . .Lot. . . . . . . . . . . . . . . . . . . . . . Permit No. . . .. .Date Of Permit. ... .. .. .. . . . . . .Applicant. Health Dept. Approval. . ./.:�-1/:. ... . .. .. .. . .....Underwriters Approval. . . .. .. . . .. . . .c.... . . . . . . . . . Planning Board Approval...... .. . . .... ... . .. .. ... Request for: Temporary Certificate. .. . . . .. .. . Final Certicate. . . . . . . . . . . Fee Submitted: $. .P.`.`� , .. .. . . . . . . . � 157 ... . ... . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . co�3aq q AP C FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 32523 Z Date NOVEMBER 29, 2006 Permission is hereby granted to: NINA S . ESHOO 345 DOUGLASS STREET ORIENT,NY 11957 for SECOND STORY ADDITION AND FIRST FLOOR ADDITIONS AND ALTERATIONS AS APPLIED FOR WITH FLOOD PERMIT AND NON-SUBSTANTIAL IMPROVEMENT REPORT at premises located at 345 DOUGLASS ST ORIENT County Tax Map No. 473889 Section 026 Block 0003 Lot No. 003 pursuant to application dated SEPTEMBER 27, 2006 and approved by the Building Inspector to expire on MAY 29, 2008 . Fee $ 649 . 60 Au o e S ' ure ORIGINAL Rev. 5/8/02 @rL3r.,f3[nCP[.![![1�[.n[J'[J�[J�[1[1[1[J�Gf[J�rJ[J�[J�[J�[.1�[J�rJ�rJ�GI[P[.CC[�n[J�[1�[.f[.�rJ�[J�t1[J�[.fflL3[.IG1[J�[.I�[1�[n[P[J�[J�[J�[J�[1�[.1-[tr MrrPrr fcP�[J� Icy 5 BY THIS CERTIFICATE OF COMPLIANCE THE 5 5 NEW YORK BOARD OF FIRE UNDERWRITERS 5 5 5 5 BUREAU OF ELECTRICITY S 5 40 FULTON STREET — NEW YORK, NY 10038 c� 5 CERTIFIES THAT 94 5 5 5 Upon the application of upon premises owned by 5 a0105 5 5 JIM SAGE ELEC. INC. NINA ESHOOPO c5 5 O GREE PORT, NY 11944-0038, ORIENT,NT, NY 1S D 1957 5 5 S 5 Located at 345 DOUGLAS RD. ORIENT, NY 11957 c5 5 5Application Number: 3063061 Certificate Number.. 3063061 S 5 5 5 S Section: Block: Lot: Building Permit: BDC: ns11 5 5 5 Described as a occupancy, wherein the premises electrical system consisting of CU electrical devices and wiring, described below, located in/on the premises at: 5 First Floor, Second Floor,Outside,Attic, 5 5 5 A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed 5 5 herein, was conducted in accordance with the requirements of the applicable code and/or standard 5 promulgated by the State of New York, Department of State Code Enforcement and Administration, or other Sauthority having jurisdiction, and found to be in compliance therewith on the 4th Day of April,2008. S 5 Name QTY Rate Rating Circuit Type 5 Miscellaneous 5 5 almost total renovation 5 5 Alarm and Emergency Equipment Sensor 2 0 Carbon Monoxide 5 Sensor 6 0 Smoke 5 Appliances and Accessories 5 5 Dish Washer 1 0 1.2 KW 5 5 Exhaust Fan 2 0 F.H.P. 5 5 Wiring and Devices 5 Outlet 64 0 Fixture S 5 Fixture 64 0 Incandescent 5 5 Outlet 95 0 General Purpose 5 5 Receptacle 48 0 General Purpose 5 5 Switch 58 0 General Purpose 5 C5Receptacle 1 0 20a Laundry 5 � Receptacle 1 0 30a Dryer 5 5 Paddle Fan 5 0 seal SReceptacle 9 0 GFCI C5J 5 Continued on Next Page 1 of 2 5 5 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. 5 5 5 o LIUMM ���rn������LPL�L�LP��������rn��������LP�������L����������rPL Q PL rr3jo lr�rJrJ�r.1�rJ'cTcJ'�J'rJ�cPtJ'3rJ�cPrJ�rJ�cTrJ�tJ'c1'c.(rJ��rJ�rJ�r�rJ'cJ'r.Pr.PrJ�cPPJ�c1rJ�t1�rJcnrJ�rJ�rJ�r�.PrJ�cPcJ'rJ�cPcJIr.17rJLFL3rcfrJ�cfrlrJrr3 5 BY THIS CERTIFICATE OF COMPLIANCE THE 5 5 NEW YORK BOARD OF FIRE UNDERWRITERS 5 5 S 5 BUREAU OF ELECTRICITY 5 5 40 FULTON STREET — NEW YORK, NY 10038 5 CERTIFIES THAT 5 5 S 5 Upon the application of upon premises owned by 5 5 SJIM SAGE ELEC. INC. NINA ESHOO 5 PO BOX 38 345 DOUGLAS RD. c5 5 GREENPORT, NY 11944-0038, ORIENT, NY 11957 5 5 5 5 Located at 345 DOUGLAS RD. ORIENT, NY 11957 5 5 c 5 Application Number: 3063061 Certificate Number: 3063061 5 5 S 5 Section: Block: Lot: Building Permit: BDC: ns11 5 5 5 Described as a occupancy, wherein the premises electrical system consisting of 5 electrical devices and wiring, described below, Located in/on the premises at: 5 First Floor, Second Floor,Outside,Attic, 5 5 A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed 5 5 herein, was conducted in accordance with the requirements of the applicable code and/or standard 5 promulgated by the State of New York, Department of State Code Enforcement and Administration, or other 5 authority having jurisdiction, and found to be in compliance therewith on the 4th Day of April,2008. 5 5 Name QTY Rate Rating Circuit Tyne 5 5 5 5 5 S 5 5 S 5 5 S 5 5 5 5 5 5 5 5 _ 5 5 5 5 5 5 5 seal 5 5 5 5 2 of 2 5 5 This certificate may not be altered in any and is validated only by the presence of a raised seal at the location indicated. 5 5 o ���������2PT, - - I I J1�������rT, I�1������yi - 002INHOMP�M o : z Town HaA, 53V95 Z:4mn Pma-d �A l77 t$i9�311Qf�$ ss�4 T.S 1802- a Box 1 179 Smdhwd,Now YOM ".971 (MCE OF THE BUILDING INSPECTOR `OWN OF SO ` HOLD E R 'T I F IC A x I 1 DATE m b V U Building Feim Lt. No . (please print% please print.) i certify LCAWi 5el a solder uze d in the water supp}Ey contains less than 2/10 of i% lead. l hers Signature ., NAGY NotaiyF'ubtic State of PJ 'vo Yf{< Wo, a735 Sworn to be f ore me this Quailfi®• in Suffolk County C Commi sior.a:vni.res Mav Po.d. day ofoD� SOUjy�lo comm,�`� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] 1 LATION [ ] FRAMING / STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: r n C2:4-j- C t DATE l INSPECTOR.,- S0UTy0 ti0 �O N C cOUNi'1,��a TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ SULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: DATE 3 INSPECTOR ho��OF SOUTyo�o courm� Q TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ \ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT C STRUCTION [ ] FIRE RESISTANT PENETRATION n , v REMARKS: - ° 2-X ti /�Q 40% I r/ "' 7 DATE INSPECTOR Of SO(/TyD�o TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [><ROUGH PLBG. [ ] FOUNDATION 2ND [ ]\INSULATION FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS-,(�A : (�- e ._ d�A�l L "L DATE ' INSPECTOR FIELD INSPECTION REPORT DATE I COMMENTS FOUNDATION(1ST) ------------------------------------- t FOUNDATION(2ND) � U� z ROUGH FRAMING& L PLUMBING .12 D� QLA d � IA INSULATION PER N.Y. STATE ENERGY CODE d P FINAL ADDITIONAL COMMENTS V, cT O z rn G � oc,o z x E� d b y ivvvi1 yr 0vv.111vLL bUILI)JNCr FEKN111 APPLIC:ATIUN CHEC;KLIS1 BUILDING DEPARTMENT Do you have or need the following,before applying: TOWN HALL Board of Health SOUTHOLD, NY 11971 . 3 sets of Building Plans . TEL: (631)765-1802 Planning Board approval FAX: (631)765-9502 Survey . www. northfork.net/Southold/ PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees Examined I'L61 ,20 Contact: Approved 20_J.6, Mail to: Disapproved a/c " Phone: -23 7 Expiration 20 Building Inspector �?�5 AP P J ICATION FOR BUILDING PERMIT �SFPP 2 2 2006 Date 7 2 20 INSTRUCTIONS a.This application MUST be.compleiely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for.any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations,for the construction of buildings, additions, or alterations or for remov 1 or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,h ing code, a dd iegulations, and to admit authorized inspectors on premises and in building for necessary inspections. � J �a . (S "ature of applicart or name,if a corporation) (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. — Electricians License No. Other Trade's License No. 1. Location of land on which proposed wor w' 1 be done. _ - t! House Number Street Hamlet County Tax Map No. 1000 Section Z,_Block Lot Subdivision Filed Map No. Lot (Name) 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy 60!�41e r1_J n,J( ��lr�c,l�G� b. Intended use and occupancy �� 3. Nature of work(check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work _ (Description) 4. Estimated Cost ;?jyjU ©lJ0 Fee — d , (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars I ' 6. If business, commercial or mixed occupancy, specify naturevand extent of each type of use. - 7. Dimensions of existing structures, if any: Front 5 ' Rear ��- Depth 36 =7" Height �,� Number of Stories__;_2 Dimensions of same structure with alterations or additions: Front � Rear ' Depth Height 2-4'-6 Number of Stories � 8. Dimensions of entire new construction: Front -- Rear -- Depth Height — Number of Stories — 9. Size of lot: Front./4 'C Rear /GCJ Depth 10. Date of Purchase 200 5 Name of Former Owner 11. Zone or use district in which premises are situated - 40 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO_,>< 13. Will lot be re-graded? YES NO Will excess fill be removed from premises? YES NOS 14. Names of Owner of premises_ Alir)--2 Address �,�,1�or1� c t 'hone No.-7 ZZ Name of Architect, arY►j��� � z�lr, ter, Address Phone No .: /-'3�- Name of Contractor Address� Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO_X _ * IF YES, SOUTHOLD TOWN TRUSTEES'& D.E.C. PERMITS MAY BE REQUIRED, b. Is this property within 300 feet of a tidal wetland? * YES NO_X * IF YES, D.E.C. PERMITS MAY BE REQUIRED, 16. Provide survey,to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) , COUNTY OFSASS: �J/G 117 '.being,duly Sworn;deposes and'says that'(s)he is the applicant (Name o individual signing contract) abov--e.named, (S)He is the ���� \ ►�-�J (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this i oZ 2 day of 2001-9 MRCS Notary Public �/ /`Signature of Applicant Notary Public, State of.New York No. 01 R16042467 !� Qualified iri 6uffolk County Commission-Expires May 30, 2002--,-;�6L r, S A M U E L S & S T E E L M A N June 11, 2007 Building Department Town of Southold 53095 Main Road Southold, NY 11971 Re: THE ESHOO RESIDENCE 345 Douglas Road Orient, NY Building Department BP# 32523Z Attn: Building Inspector I hereby certify that all poured concrete piers have been install as per our drawings and specifications and was observed by me prior to backfilling. Th4%113an, Sael Architects oF NiWwa R.A. �r cc: Wayne Langer ARCHITECTS 25235 MAIN ROAD CUTCHOGUE,NEW YORK 11935 (631)734-6405 FAX(631)734-6407 Permit# Permit Date REScheck Software Version 3.7.3 Compliance Certificate Project Title: Eshoo Residence Report Date:09/22/06 Data filename:Z:\ACTIVE PROJECTS\Eshoo\Res Check.rck Energy Code: New York State Energy Conservation Construction Code Location: Suffolk County,New York Construction Type: Detached 1 or 2 Family Heating Type: Non-Electric Glazing Area Percentage: 17% Heating Degree Days: 5750 Construction Site: Owner/Agent: Designer/Contractor: 345 Douglas Rd Nina Eshoo Nancy Steelman Orient,NY 11957 50 East 10th St Samuels&Steelman Architects New York,NY 10003 25235 Main Road Cutchogue,NY 11935 631 734-6405 Ceiling 1:Cathedral Ceiling(no attic): 1107 30.0 2.0 35 Wall 1:Wood Frame,16"o.c.: 1043 19.0 2.0 49 Window 1:Wood Frame:Double Pane with Low-E: 177 0.330 58 Floor 1:All-Wood Joist/Truss:Over Unconditioned Space: 1107 19.0 0.0 52 Furnace 1:Forced Hot Air:78 AFUE The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted�with this permit a plication.The proposed systems have been designed to meet the New York State Energy Conservation Coonstrucgfbn Code requifer ents.Wh n a Registered Design Professional has stamped and signed this page,they are attesting that o the�lti5st of his/h r kn Ilvledge,bel' f,and professional judgm nt,su h plans or sp cifications are in compliance wit this Code. I � w /Builder/Designer-� Company Name /.ln ��G Dat Project Notes: u 1 Project Description: Second Floor Addition Eshoo Residence Page 1 of 4 REScheck Software Version 3.7.3 Inspection Checklist t:/j Date:09/22/06 Ceilings: ❑ Ceiling 1:Cathedral Ceiling(no attic),R-30.0 cavity+R-2.0 continuous insulation Comments: Above-Grade Walls: ❑ Wall 1:Wood Frame,16"o.c.,R-19.0 cavity+R-2.0 continuous insulation Comments: Windows: ❑ Window 1:Wood Frame:Double Pane with Low-E,U-factor:0.330 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Floors: ❑ Floor 1:All-Wood Joist/Truss:Over Unconditioned Space,R-19.0 cavity insulation Comments: Heating and Cooling Equipment: ❑ Furnace 1:Forced Hot Air:78 AFUE or higher Make and Model Number: Air Leakage: ❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. ❑ Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: ❑ Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: ❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment must be identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. ❑ Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: ❑ Supply ducts in unconditioned attics or outside the building must be insulated to R-8. ❑ Return ducts in unconditioned attics or outside the building must be insulated to R-4. ❑ Supply ducts in unconditioned spaces must be insulated to R-8. ❑ Return ducts in unconditioned spaces(except basements)must be insulated to R- ❑ Return ducts in unconditioned spaces(except basements)must be insulated to R-2. .Insulation is not required on return ducts in basements. Duct Construction: ❑ All joints,seams,and connections must be securely fastened with welds,gaskets,mastics(adhesives), mastic-plus-embedded-fabric,or tapes.Tapes and mastics must be rated UL 181A or UL 181 B. Eshoo Residence Page 2 of 4 Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). ❑ The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ❑ Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: ❑ Separate electric meters are required for each dwelling unit. Fireplaces: ❑ Fireplaces must be installed with tight fitting non-combustible fireplace doors. ❑ Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: ❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: ❑ Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: ❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps require a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. Eshoo Residence _ Page 3 of 4 I Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water ' Temperature(°F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes I Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range ff) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condenslate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) I i I I I I I i I i i I i I II I Eshoo Residence Page 4 of 4 I i 1 S A M U E L S & T E E L M A N N&, "* ber 2$ ,:20''1 Z'Iis, Damonl Building Department Town of Southold 53095 Main Road Southold, NY 1111971 Re: Eshoo Residence 345 Douglas Road Orient,ANY Dear Damon, ' I As requested,lwe are submitting for your review, an Appraisal Report for the Eshoo Residence and a Construction Cost breakdown for the proposed new construction. The following is a summary of the appraisal and the constructions costs. Appraisal of the existing structure: $398,720 Fifty Percent (%) Allowable: $199,360 Total Construction Costs: $195,950 1 As you can see, the value of the proposed project is less than 50% of the appraised value of the existing house, and therefore is not a substantial improvement. i If you have any questions, please do not hesitate to call. Sincerely, Samuel Steelma Architects `�� . ST� � ancy S elman, R.A. ARCHITECTS 25235 MAIN ROAD CUTCHOGUE,NEW YORK 11935 (631)734-6405 FAX(631)734-6407 I i i S A M U E L S & S T E E L M A N ESHOO RESIDENCE CONSTRUCTION COSTS November 27, 2006 For the purpose of evaluating FEMA compliance, the following is a breakdown of costs for the proposed new construction at the Eshoo Residence. 1. Construction of a new Second Floor- Remove existing roof deck and second floor (2 Bedrooms and Bath). Construct new second floor with 3 new bedrooms and Bath. Total square feet:. 1105 SF Square foot cost: $135/SF Total Construction Cost: $149,175 i 2. Construction of a new Screen Porch - Reuse a portion of the existing deck structure (150 SF) and add 225 SF of decking, a roof structure and screen panels! Total square feet: 375 SF Square foot cost: $75/SF Total Construction Cost: $28,125 I 3. Construction of a new roof over the existing Garage - Remove existing roof structure and construct a new roof structure over the existing garage. Total square feet: 746 SF Square foot cost: $25/SF Total Construction Cost: $18,650 4. Construction of a new Entry Porch and terrace is in Zone X. 5. In addition to the new construction above, there are several maintenance related litems which include the following: replacing existing windows with energy efficient windows in existing openings; replacing existing entry door and garage door; new siding on existing exterior walls; replacing outdated plumbing fixtures in existing bathrooms; painting; floor refinishing; and replacing existing rotted decking. These items do not require a building permit. ARCHITECTS 25235 MAIN ROAD CUTCHOGUE, NEW YORK 11935 (631)734-6405 FAX(631)734-6407 i it I NORTH FORK APPRAISAL SERVICES I File No.NF6014 I I 11/22/2006 I (Samuels Steelman Architects 25235 Main Road �Cutchogue,NY 11935 II have personally completed a partial cost approach to value of the real property at 345 Douglas Road,Orient,NY 11957. The purpose of this appraisal was to develop a total estimated replacement cost of the structure less the physical depreciation. The property rights appraised are the fee simple interest in the site improvements. (The intended user of this appraisal report is Samuels and Steelman Architects on behalf of Nina S.Eshoo. This appraisal report will be used as a guide for future home improvements. It is my opinion that the total estimated replacement cost of the structure less the physical depreciation is$398,720. SCOPE OF WORK I To complete this assignment I completed the following: Viewed the subject site and surrounding properties to note any external influences on the subject property. I Inspected the exterior and the interior of the subject house and improvements to evaluate the physical characteristics and condition of all;the improvements. Researched economic data,town assessor records. Interviewed local builders to observe recent trends of Building costs in the subjects market area. Analyzed the data collected and completed the cost approach for the subject dwelling and the attached improvements. Prepared this Limited Summary Appraisal Report in accordance with Standards Rule 2-2(b)of the Uniform Standards of Professional Appraisal Practice. As such,it presents sufficient information to enable the client and other intended users,as identified to understand it properly. I I Donald G. Stirnweis I i I I I I 238 Long Island Avenue,Holtsville,NY 11742 Phone-631-654-9045 Fax-631-654-3324 RW.W usUN AG.0—=234.0227—..a b— TXT3 I I SUMMARY REPORT Prooertv Descri tion UNIFORM RESIDENTIAL APPRAISAL REPORT File No. NF6014 Property Address 345 Douglas Road City Orient State NY Zi Code 11957 Legal Description District:1000 Section:26 Block:3 Lot:3 SMSA#5380 County Suffolk Assessor's Parcel No.N/A Tax Year 05/06 R.E.Taxes$5167.9D Special Assessments$ None Borrower N/A Current Owner Nina S.Eschoo Occu ant: X Owner Tenant Vacant „ Property rights appraised I X I Fee Sim le Leasehold Project Type I I PUD Condominium UDNA on HOA$ None /Mo. Neighborhood or Project Name N/A Map Reference Hag Map 32 E-47 Census Tract 1702.02 Sale Price$N/A Date of Sale N/A Description and$amount of loan charges/concessions to be paid by seler N/A Lender/Client Samuels Steelman Architects Address 25235 Main Road Cutchogue,NY 11935 A raiser Donald G.Stirnweis Address 238 Long Island Avenue Holtsville NY 11742 Location Urban X Suburban Rural Predominant Single family housing Present land use% Land use change Built up ❑Over 75% X❑25-75% ❑Under 25% occupancy PRICE AGE One family 60% X❑Not likely ❑Likely Growth rate ❑Rapid X❑Stable ❑Slow X❑Owner 450 Low New 2.4 family ❑In process Property values ❑Increasing X❑Stable ❑Declining ❑Tenant 2700 High 20D+ Multi-family To: Demand/supply ❑Shortage El In balance ❑Oversupply X❑Varzit(05°G) :i'%Predominant -:E Commercial 1% Marketing time L Under 3 mos. X 3-6 mos. F Over 6 mos. F varan avers%1 750 75 tVac/Other 39 Note:Race and the racial composition of the neighborhood are not appraisal factors. Neighborhood boundaries and characteristics: The boundaries of the subject neighborhood are the Long Island Sound to the north,Orient Point to the east,Orient Harbor to the south,and Damn Pond to the west Factors that affect the marketability of the properties in the neighborhood(proximity to employment and amenities,employment stability,appeal to market,etc.): The sub'ecls neighborhood is predominantly comprised of single family homes,surrounded by farm land,vineyards,and nurseries. The subject has access to " all necessary supporting facilities including schools shopping,public beaches,marinas and recreation facilities. Public transportation to New York City is provided by the Long Island Rail Road. Southold Town's economic base is composed of agriculture,fishing,tourism and retail trade. Suffolk County has a diverse economy with stable employment. In recent years the unemployment in Suffolk County has remained below the national average because of job growth in the high tech and service Industries.There are no known adverse factors that would negatively affect the subject neighborhoods good market appeal. Market conditions in the subject neighborhood(including support for the above conclusions related to the trend of property values,demand/supply,and marketing time --such as data on competitive properties for sale in the neighborhood,description of the prevalence of sales and financing concessions,etc.): A review of sale transactions recorded in the Suffolk County Clerks office and reported by the Multiple Listing Service of Long Island shows prices had been increasing from January 1998 to June 2005. Multiple Listing Service data as well as discussions with local brokers indicates that the prices have become stable and the typical house sells in 3 to 6 months. The strong economic and social conditions of the region along with no adverse influences or evidence of an negative trends at the present time,the overall outlook for the neighborhood should remain strong. _ Project Information for PUDs(If applicable)--Is the developerlbuilder in control of the Home Owners'Association(HOA)7 LJ YES X NO Approximate total number of units in the subject project N/A Approximate total number of units for sale in the subject project NIA Describe common elements and recreational facilities:N/A Dimensions 1D0x175x100xl75 Topography Level Site area 17,500 Square Feet/.40 Acre Corner Lot CTYes X No Size Typical For The Area Specific zoning classification and description R-40 Residence-Sin le Famil Shape Rectangular Zoning compliance ❑Legal X❑Legal nonconfo ming(Grandlathe ed use) Illegal LJ No zoning Drainage Appears Adequate Highest&best use as improved: 0 Present use Other use(explain) View Residential Utilities Public Other Off-site Improvements Type Public Private Landscaping Typical Electricity 0 100 Amp C.B. Street Asphalt X❑ ❑ Driveway Surface Asphalt Gas ❑None Curb/gutter None ❑ ElApparent easements NoneA anent Water ❑Well Sidewalk None ❑ , ❑ FEMA Special Flood Hazard Area Yes X No sanitary sewer Elcesspool Street lights None ❑ ❑ FEMA Zone AE(EL9) Map Date 05/04/98 Storm sewer F None Alley Nona F F FEMA Map No. 36103CO068 G Comments(apparent adverse easements,encroachments,special assessments,slide areas,illegal or legal nonconforming zoning,use,etc.): See attached addendum. GENERAL DESCRIPTION EXTERIOR DESCRIPTION FOUNDATION BASEMENT INSULATION No.of Units 1 Foundation Concrete Slab None Area Sq.Ft. 0 Roof Enclosed Q No.of Stories 1 Exterior Walls Cedar Crawl Space Yes %Finished N/A Ceiling Enclosed Q Type(Det./Att.) Detached Roof Solace Asphalt Shingle Basement None Ceiling N/A Walls Enclosed Q Design(Style) Exo Cape Gutters&Dwnspts. Aluminum Sump Pump None Walls N/A Floor Enclosed ❑ Existing/Proposed Existing Window Type Casement Dampness None Noted Floor N/A None ❑ Age(Yrs.) 30 Storm/Screens ThermagScreens Settlement None Noted Outside Entry N/A enk—n X❑ Effective Acie(Yrs.) 8-12 Manufactured House No Infestation None Noted ROOMS Foyer Livinq Dininq Kitchen Den Family Rm. Rec.Rm. Bedrooms N Baths Laundry Other Area S .Ft. Basement 0 Levell 1 1 1 2 1 x 1659 Leve12 2 1 720 Finished area above grade contains: 7 Rooms: 4 Bedrooms: 2 Baths: 2,379 So are Feet of Gross Living Area INTERIOR Materials/Condition HEATING KITCHEN EQUIP. ATTIC AMENITIES CAR STORAGE: Floors Wood Ceramic Type HotWaler Refrigerator X❑ None ❑ Fireplace(s)#Brick 2 None ❑ Walls Drywall Fuel Oil Range/Oven 2❑ Stairs ❑ Patio ❑ Garage 1 #of cars Trim/Finish Wood ConditionAvera a Disposal ❑ Drop Stair ❑ Deck Multi Level X❑ Attached X Bath Floor Ceramic Tile COOLING Dishwasher X❑ Scuttle X❑ Porch ❑ Detached Bath Wainscot Ceramic Tile Central Yes Fan/Hood X❑ Floor ❑ Fence ❑ Built-In Doors Wood Other None Microwave ❑ Heated ❑ Pool ❑ Carport All of the above are in good condition. ConditbnAvera a i Washer/Dryer [X1,Finished Driveway Yes Additional features(special energy efficient items,etc.): Thermal windows. Condition of the improvements,depreciation(physical,functional,and external),repairs needed,quality of construction remodeling/additions,etc.: See attached addendum. Adverse environmental conditions(such as,but not limited to,hazardous wastes,toxic substances,etc.)present in the improvements,on the site,or in the immediate vicinity of the subject property:No known or apparent adverse environmental conditions were noted at the time of inspection that would negatively affect the value of the property. If the client has a concern a qualified environmental expert should be consulted. Fr.Mm Mac F-70 6-93 PAGE OF Fannie Mae F-1004 6-93 R..W using AG saw,8W2N.8727—...b.— SUMMARY REPORT Valuation Section UNIFORM RESIDENTIAL APPRAISAL REPORT File No. NF6014 ESTIMATED SITE VALUE•,•,•••••.•••,••••.•...,..•=$ 300000 Comments on Cost Approach(such as,source of cost estimate, ESTIMATED REPRODUCTION COST-NEW OF IMPROVEMENTS: site value,square foot calculation and for HUD,VA and FmHA,the Dwelling 2,379 Sq.Ft.0$ 150.00 =$ 356,850 estimated remaining economic life of the property): Craw11659 Sq.R.0$ 30.00 = 49,770 The estimated reproduction costs are considered common and typical 2 Fire Iaces,Bi-level Deck,CAC,Cess ool,Ddvewe = 50,000 for this area. They were derived by surveying local builders. These GaragelCarport 342 Sq.Ft.0$ 50.00 = 17,100 costs are significantly higher than other areas of Suffolk County because Total Estimated Cost New ••••••••••..•••. =$ 473,720 of the the lack of competition on the North Fork of Long Island. The acle Less 60 Physical I Functional External Est.Remaining Econ.Life: 47 -life method of estimating physical depreciation was used in this Depreciation $75,000 =$ 75,000 appraisal.The subject has a remaining economic life of 48 to 52 years. Depreciated Value of Improvements•.•••••••••••...... .=$ 398,720 The dollar amount of the external depreciation Is attributed to the subject 'As-is"Value of Site Improvements••••••,•••,••••••,• =$ 5,000 dwelling and attached improvements only. INDICATED VALUE BY COST APPROACH•••••••••• =$ 703 700 ITEM SUBJECT COMPARABLE NO,1 COMPARABLE NO.2 COMPARABLE NO.3 345 Douglas Road N/A N/A N/A Address Orient Proximity to Subject Sales Price $ N/A 1$ $ $ Price/Gross Liv.Area $ 0.00V1 $ rdl. `$ fdis $ Data and/or Comps Inc Verification Sources Ins action VALUEADJUSTMENTS DESCRIPTION DESCRIPTION .(-If Ad ad DESCRIPTION .0SAd oa DESCRIPTION .t)$naa:uaai Sales or Financing N/A Concessions Date of Salefrime N/A Location Average LeasehokDFeeSimple Fee Simple Site .40 Acre View Resident/Average Design and Appeal Expanded Cape QuakyofConshdon I Average A e 30 Years Condition Good Above Grade Tali;Bdrms' Bws mni;Barns' eau raw;Btrms' ea s Taal;B&-' Bahs Room Count 50 7; 4: 2.00 Gross Living Area 2,379 S .Ft. S.Ft. S.Ft. S .Ft. Basement&Finished Crawl Space - Rooms Below Grade N/A Functional Utility Average _ Heatin ICoolin Oil Hot Water/CAC Ene Efficient Thermal Windows Gars a/Car ort 1 Car Garage Porch,Patio,Deck, Bi-level Deck Fire laces,etc. 2 Brick Fire laces Fence,Pool,etc. Fence Miscellaneous None Net Ad'.(total) X + ;$ 0 TXT, ;$ 0 X + '$ 0 Adjusted Sales Price Gross 0 01 §)§ Gross:q.0/o Gross:0 Oab of Com arable Net 0.03k i$ 0 Net �0.0% $ 0 1 Net: 0.05 j$ 0 Comments on Sales Comparison(including the subject property's compatibility to the neighborhood,etc.): See attached addendum ITEM SUBJECT COMPARABLE NO.1 COMPARABLE NO.2 COMPARABLE NO.3 Date,Price and Data 11/15/2004 Source for prior sales $635,000 within Yearof aonraisal Com s Inc. Analysis of any current agreement of sale,option,or listing of the subject property and analysis of any prior sales of subject and coWambles within one year of the date of appraisal: Title to the subject property has was conveyed on November 15th 2004. The sale price was$635 000. The subject is not currently listed nor has it been in the last 12 months. INDICATED VALUE BY SALES COMPARISON APPROACH••,••••••••..........................................$ N/A INDICATED VALUE BY INCOME APPROACH If Applicable)Estimated Market Rent$ N/A /Mo.x Gross Rem MuIG her N/A =$ N/A This appraisal is made X❑ was is' ❑subject to the repairs,alterations,inspections or conditions listed below ❑subject to completion per plans and specifications. Conditions of Appraisal: All normal limitations apply.This is a partial cost approach appraisal presented in a summary format. Final Reconciliation:N/A • The purpose of this appraisal is to estimate the market value of the real property that is the subject of this report,based on the above conditions and the certification,contingent and limiting conditions,and market value definition that are stated in the attached Freddie Mac Form 439/Fannie Mae Form 1004B(Revised 6193 ). I M ESTIMATE THE MARKET VALUE,AS DEFINED,OF THE REAL PROPERTY THAT IS THE SUBJECT OF THIS REPORT,AS OF 11/15/2006 (WHICH IS THE DATE OF INSPECTION AND THE EFFIE ATE OF THIS REPORT)TO BE$ N/A ' APPRAISER: SUPERVISORY APPRAISER(ONLY IF REQUIRED): Si nature ( Signature []Did ❑Did Not Name Do ald G.Stimweis Name Inspect Property Date Report Signed 11/27/2006 Date Report Signed State Certification F 45000023431 State NY State Certification N State Or State License# State Or State License fi State Frame Mac Farm 70 693 PAGE 2OF2 F—da Mae F-1004 693 Produced u,g AG mcwae,M23/8727 vmw web.com APPRAISAL SERVICES ADDENDUM File No. NF6014 Zoning Classification And Description The subjects specific zoning classification is R 40 Residential Low-Density Residence. The minimum lot size is 40,000 square feet. The minimum lot width is 150 feet. The subject pre-exists current zoning with regard to frontage and lot size requirements.This is common as many areas have been up zoned in order to reduce population density.Discussions with the municipality revealed that if the subject were to be destroyed by fire,a new building permit would customarily be granted if a certificate of occupancy was in place for the original structure. Site Comments No adverse easements,encroachments,or other conditions were evident at the time of inspection. The subject site has no public gas,water or sanitary sewer. Well water,and cesspools are common to the area and have no adverse affect on marketability. At the time of inspection,the cesspools appeared to be operating properly with no seepage or percolation noted. There is a 275 gallon oil tank located in the garage. There was no evidence of any leaks at the time of the appraisal. Condition of Improvements The overall quality of construction of the subject house is compatible to the neighborhood and considered good. It has been well maintained and is in overall good condition with no immediate major repairs or modernization needed.The paint on the exterior siding on the rear of the house is peeling and needs to be repainted. The effective age of the subject dwelling is less than the actual age because this home has been occupied as a second home and is not subject to as much wear and tear as a home that is occupied as a primary residence. Additional Certification My compensation for completing this assignment is not contingent upon the development or reporting of a predetermined value or direction in value that favors the cause of the client,the amount of the value opinion,the attainment of a stipulated result,or the occurrence of a subsequent event directly related to the intended use of this appraisal. The signatures on this report may be digitally reproduced.The undersigned has taken adequate precautions to insure the security of the report. I certify that,to the best of my knowledge,and belief,the report analyses,opinions and conclusions were developed,and this report has been prepared,in conformity with the requirements of the Uniform Standards of Professional Appraisal Practice. Addendum Page I of I File No. NF6014 DEFINITION OF MARKET VALUE: The most probable price which a property should bring in a competitive and open market under all conditions requisite to a fair sale,the buyer and seller,each acting prudently,knowledgeably and assuming the price is not affected by undue stimulus. Implicit in this definition is the consummation of a sale as of a specified date and the passing of title from seller to buyer under conditions whereby:(1)buyer and seller are typically motivated;(2)both parties are well informed or well advised, and each acting in what he considers his own best interest;(3)a reasonable time is allowed for exposure in the open market;(4)payment is made in terms of cash in U.S.dollars or in terms of financial arrangements comparable thereto;and(5)the price represents the normal consideration for the property sold unaffected by special or creative financing or sales concessions'granted by anyone associated with the sale. 'Adjustments to the comparables must be made for special or creative financing or sales concessions. No adjustments are necessary for those costs which are normally paid by sellers as a result of tradition or law in a market area;these costs are readily identifiable since the seller pays these costs in virtually all sales transactions. Special or creative financing adjustments can be made to the comparable property by comparisons to financing terms offered by a third party institutional lender that is not already involved in the property or transaction. Any adjustment should not be calculated on a mechanical dollar for dollar cost of the financing or concession but the dollar amount of any adjustment should approximate the market's reaction to the financing or concessions based on the Appraisers judgment. STATEMENT OF LIMITING CONDITIONS AND APPRAISER'S CERTIFICATION CONTINGENT AND LIMITING CONDITIONS: The appraiser's certification that appears in the appraisal report is subject to the following conditions: 1. The appraiser will not be responsible for matters of a legal nature that affect either the property being appraised or the title to it. The appraiser assumes that the title is good and marketable and,therefore,will not render any opinions about the title. The property is appraised on the basis of it being under responsible ownership. 2. The appraiser has provided a sketch in the appraisal report to show approximate dimensions of the improvements and the sketch is included only to assist the reader of the report in visualizing the property and understanding the appraisers determination of its size. 3. The appraiser has examined the available flood maps that are provided by the Federal Emergency Management Agency(or other data sources)and has noted in the appraisal report whether the subject site is located in an identified Special Flood Hazard Area. Because the appraiser is not a surveyor,he or she makes no guarantees,express or implied,regarding this determination. 4. The appraiser will not give testimony or appear in court because he or she made an appraisal of the property in question,unless specific arrangements to do so have been made beforehand. 5. The appraiser has estimated the value of the land in the cost approach at its highest and best use and the improvements at their contributory value. These separate valuations of the land and improvements must not be used in conjunction with any other appraisal and are invalid if they are so used. 6. The appraiser has noted in the appraisal report any adverse conditions(such as,needed repairs,depreciation,the presence of hazardous wastes,toxic substances,etc.)observed during the inspection of the subject property or that he or she became aware of during the normal research involved in performing the appraisal. Unless otherwise stated in the appraisal report,the appraiser has no knowledge of any hidden or unapparent conditions of the property or adverse environmental conditions(including the presence of hazardous wastes,toxic substances,etc.)that would make the property more or less valuable,and has assumed that there are no such conditions and makes no guarantees or warranties,express or implied,regarding the condition of the property. The appraiser will not be responsible for any such conditions that do exist or for any engineering or testing that might be required to discover whether such conditions exist. Because the appraiser is not an expert in the field of environmental hazards,the appraisal report must not be considered as an environmental assessment of the property. 7. The appraiser obtained the information,estimates,and opinions that were expressed in the appraisal report from sources that he or she considers to be reliable and believes them to be true and correct. The appraiser does not assume responsibility for the accuracy of such items that were furnished by other parties. 8. The appraiser will not disclose the contents of the appraisal report except as provided for in the Uniform Standards of Professional Appraisal Practice. 9. The appraiser has based his or her appraisal report and valuation conclusion for an appraisal that is subject to satisfactory completion, repairs,or alterations on the assumption that completion of the improvements will be performed in a workmanlike manner. 10. The appraiser must provide his or her prior written consent before the lender/client specified in the appraisal report can distribute the appraisal report(including conclusions about the property value,the appraiser's identity and professional designations,and references to any professional appraisal organizations or the firm with which the appraiser is associated)to anyone other than the borrower;the mortgagee or its successors and assigns;the mortgage insurer;consultants;professional appraisal organizations;any state or federally approved financial institution;or any department,agency,or instrumentality of the United States or any state or the District of Columbia; except that the lender/client may distribute the property description section of the report only to data collection or reporting service(s) without having to obtain the appraiser's prior written consent. The appraiser's written consent and approval must also be obtained before the appraisal can be conveyed by anyone to the public through advertising,public relations,news,sales,or other media. Freddie Mac Form 439 6.93 Page 1 of 2 Fannie Mae Form 1004B 6-93 File No. NF6014 APPRAISERS CERTIFICATION: The Appraiser certifies and agrees that: 1. 1 have researched the subject market area and have selected a minimum of three recent sales of properties most similar and proximate to the subject property for consideration in the*sales comparison analysis and have made a dollar adjustment when appropriate to reflect the market reaction to those items of significant variation. If a significant item in a comparable property is superior to,or more favorable than, the subject property,I have made a negative adjustment to reduce the adjusted sales price of the comparable and,if a significant item in a comparable property is inferior to,or less favorable than the subject property,I have made a positive adjustment to increase the adjusted sales price of the comparable. 2. 1 have taken into consideration the factors that have an impact on value in my development of the estimate of market value in the appraisal report. I have not knowingly withheld any significant information from the appraisal report and I believe,to the best of my knowledge,that all statements and information in the appraisal report are true and correct. 3. 1 stated in the appraisal report only my own personal,unbiased,and professional analysis,opinions,and conclusions,which are subject only to the contingent and limiting conditions specified in this form. 4. 1 have no present or prospective interest in the property that is the subject to this report,and I have no present or prospective personal interest or bias with respect to the participants in the transaction. I did not base,either partially or completely,my analysis and/or the estimate of market value in the appraisal report on the race,color,religion,sex,handicap,familial status,or national origin of either the prospective owners or occupants of the subject property or of the present owners or occupants of the properties in the vicinity of the subject property. 5. 1 have no present or contemplated future interest in the subject property,and neither my current or future employment nor my compensation for performing this appraisal is contingent on the appraised value of the property. 6. 1 was not required to report a predetermined value or direction in value that favors the cause of the client or any related party; the amount of the value estimate,the attainment of a specific result,or the occurrence of a subsequent event in order to receive my compensation and/or employment for performing the appraisal. I did not base the appraisal report on a requested minimum valuation,a specific valuation,or the need to approve a specific mortgage loan. 7. I performed this appraisal in conformity with the Uniform Standards of Professional Appraisal Practice that were adopted and promulgated by the Appraisal Standards Board of The Appraisal Foundation and that were in place as of the effective date of this appraisal, with the exception of the departure provision of those Standards,which does not apply. I acknowledge that an estimate of a reasonable time for exposure in the open market is a condition in the definition of market value and the estimate I developed is consistent with the marketing time noted in the neighborhood section of this report,unless I have otherwise stated in the reconciliation section. B. 1 have personally inspected the interior and exterior areas of the subject property and the exterior of all properties Iisted as comparables in the appraisal report. I further certify that I have noted any apparent or known adverse conditions in the subject improvements,on the subject site,or on any site within the immediate vicinity of the subject property of which I am aware and have made adjustments for these adverse conditions in my analysis of the property value to the extent that I had market evidence to support them. I have also commented about the effect of the adverse conditions on the marketability of the subject property. 9. I personally prepared all conclusions and opinions about the real estate that were set forth in the appraisal report. If I relied on significant professional assistance from any individual or individuals in the performance of the appraisal or the preparation of the appraisal report,I have named such individual(s)and disclosed the specific tasks performed by them in the reconciliation section of this appraisal report. I certify that any individual so named is qualified to perform the tasks. I have not authorized anyone to make a change to any item in the report;therefore,if an unauthorized change is made to the appraisal report,I will take no responsibility for it. SUPERVISORY APPRAISER'S CERTIFICATION: If a supervisory appraiser signed the appraisal report,he or she certifies and agrees that:I directly supervise the appraiser who prepared the appraisal report,have reviewed the appraisal report,agree with the statements and conclusions of the appraiser,agree to be bound by the appraiser's certifications numbered 4 through 7 above,and am taking full responsibility for the appraisal and the appraisal report. ADDRESS OF PROPERTY APPRAISED: 345 Douglas Road Orient NY 11957 APPRAISER: ¢� SUPERVISORY APPRAISER(only if required) Signature: '�R ✓� Signature: Name: Don ffd``GG..Stirnweils Name: Date Signed: 11/27/2006 Date Signed: State Certification#: 45000023431 State Certification#: or State License#: or State License#: State:NY State: Expiration Date of Certification or License: 01/02/2006 Expiration Date of Certification or License: ❑ Did ❑ Did Not Inspect Property State Certified Residential Appraiser Freddie Mac Form 439 6-93 Page 2 of 2 Fannie Mae Form 1004B 6-93 FLOORPLAN File No. NF6014 60.5' Deck 50.0' 0 N O [7 Dining Bedroom Bath Room Kitchen 3.5' 1/2 . 0 Bath m 7.0' co co 16.0' Living Room u-; 0 o; Bedroom Garage N 15.5' 18.0' skean by Ape.N- Comments: AREA CALCULATIONS SUMMARY LIVING AREA BREAKDOWN Code Description - Size Net Totals I Breakdown Subtotals GLAl First Floor 1659.00 1659.00 First Floor P/P First floor Deck 702.00 702.00 11.5 x 23.0 264.50 GAR Garage 342.00 342.00 2.0 x 6.0 12.00 0.5 x 2.8 x 2.0 2.75 0.5 x 2.8 x 2.0 2.75 2.5 x 23.0 57.50 21.5 x 23.0 494.50 8.0 x. 18.0 144.00 2.0 x 15.5 31.00 13.0 x 5o.o 650.00 TOTAL LIVABLE (rounded) 1659 9 Calculations Total(rounded) 1659 FLOORPLAN File No. NF6014 53.5' N Deck i N 36.0' Bath 0 0 N Bedroom Bedroom 36.0' Sk.1 by Apex W- Comments: AREA CALCULATIONS SUMMARY LIVING AREA BREAKDOWN Code Description size Net Totals Breakdown Subtotals GLA2 second Floor 720.00 720.00 second Floor P/P second L-1 Deck 642.00 642.00 20.0 x 36.0 720.00 TOTAL LIVABLE (rounded) 720 1 Calculation Total(rounded) 720 4010 TOWN OF SOUTHOLD PROPERTY RECORD CARD A/-,2 N R STREET 3 VILLAGE DIST. SUB. LOT to- .60 Dou 4 /as's jh�e FORMER OWNER ;robe r+ f!pmo J , ACR. S, W TYPE OF BUILDING El RES. �. ' SEAS. VL. FARM COMM. CB. MISC. Mkt. Value LAND IMP. TOTAL DATE . REMARKS 4- ITY //"//z 7,0 /a 4 a'? NEW NORMAL BELOW AB VE �{ a& F57- =Fo - FARM Acre Value aAcre Per Value 1 3 q.4—L Tillable 1 S o -L 2-3, 7 �C/�GL 0 r 6 p Tillable 2 tillable 3 Hoodland Swampland FRONTAGE ON WATER 3rushland FRONTAGE ON ROAD a f -louse Plot DEPTH d a BULKHEAD f otal DOCK- - i ■■■■■■ "■PRIN!!1NIM- ■■■■■■■■■■■■ R1Sffi 2821 AE15FdFd5 . ■■■■■'®■ �L.il�■�.��-��■■■■■■■■■■■ 3 = ' ■■■■■■ ■:R"REMNEIM■■■■■■■■■■■ ■■■■■■■ ■■■■■■■■■■■■■■■■■■■■ Basement ' - it / / f Interior � • BUILDING PERMIT EXAMINER CHECKLIST *Date Submitted.? rVA0/07*Date Reviewed:114?.J/ 7 Applicant: SP4ja)fts I Owner: 2S__-C -k o _ rc i e ngineer: 1►U`F}�3cu Estimated Cost: SCTM# 1000- oPr - 3 - 3 Subdivision: Zone: — Conforming? Property Address:3*J �� St. City: (f�)Revt� Pre COs? Buildin Permits (Open/Expired): BPn®I -Z/C/o Z- 73P ,Info: N15 BP«7 -Z/C/o Z- C 3,Info: BP -Z/C/O Z-JK1tq,Info:BP -Z/C/O Z- ,Info: BP -Z/C/0 Z- ,Info: Single& Separate Search Required? Y N��etermination: ta Lk REQ. Lot Size. ACT. Lot Size: �7, (42 PQ Lot Cov�ACT. Lot Cov. REQ. Front ACT. Front _REQ Side ACT. Side o REQ. Rear PROP. Ream REQ. Height ACT. Height Project Description:G�' L Waterfront? Y o ? If yes,water body: Panel# Flood Zone'AE ! Bulkhead/Bluff Distance: ADDITIONAL APPROVALS REOUIRED Suffolk County Health: Y or VIf yes, *Bed#: *Date: /_�Pe • Town Septic: Y or T - If no, certification required: Y ec ived: Y or N By: Z4 y b;f� o& NYS DEC: PRE-DEC 9/1/75 Y 00 Date: _/_/_ Permit#: or NJ Letter—Notes: Southold Trustees: Y o NOD- ate: / / Permit#: or NJ Letter—Notes: Southold ZBA: Y 00 Date: / / Permit#: —Notes: Southold Planning: Y o(&ate: / / Permit#: —Notes: Town Landmark C of A: Y o TE: / / *NYS CODE Compliance (page A61or N Notes Fee Structure: Calculation: Foundation: SF 1. SF SF -I = I3 SF X $a30 _$ c39q�Q cam_ > �'a ) First Floor: g9a SF +Initial Fee: $ 1,50 Second Floor: 1 )(60 SF +Additional Fee ( IDS $ /00 Other: SF 2. ( SF)- ( SF)= SF X $ =$ Total: C3 I _SF +Initial Fee: $ +Additional Fee TO AL: $ NEW YORK STATE CODE COMPLIANCE CHECKLIST CLIMATIC/GEOGRAPHIC DESIGN CRITERIA: Ground Snow Load: 45 Wind Speed: 120MPH Seismic Design Category:B Weathering: Severe Frost Depth: 36" Termite: M-H' Decay: S-M Design Temp: I I Iee Shield Underlay:YES Flood Hazards: USE/OCCUPANCY CLASSIFICATION: HEIGHT/FIRE AREA: TYPE OF CONSTRUCTION: DESIGN CRITERIA: ENGINEERED/PRESCRIPTIVE FULL FRAMING DESIGN ELEMENTS: Y/N HEADERS: Y/N WALL STUDS:Y/N GIRDERS: Y/N CEILING JOISTS: Y/N FLOOR JOISTS:Y/N ROOF RAFTERS: Y/N LUMBER SPECIES AND GRADE:Y/N DESIGN LOAD CALCULATIONS: Y/N LIVE: Y/N DEAD: Y/N SNOW: Y/N SEISMIC: Y/N WIND: Y/N WINDOW AND DOOR SCHEDULE: MISSLE TEST REQUIREMENTS: Y/N EGRESS 5.7 S.F.: Y/N LIGHT 8%: Y/N VENT 4%: Y/N NAILING/CONSTRUCTION SCHEDULE: Y/N MEANS OF EGRESS: Y/N PLUMBING RISER DIAGRAM: Y/N LOCATION OF FIRE PROTECTION EQUIPMENT: Y/N TRUSS DESIGN: Y/N CERTIFICATION: Y/N ENERGY CALCS: Y/N TOTAL COMPLIENCE? Y/N (RETURN TO PAGE ONE) SITE DATA SCTM # 1000-26-3-3 PROPERTY: 345 DOUGLAS ROAD ADRESS ORIENT NEW YORK OWNER: NINA ESHOO 50 EAST 10th STREET New York, NY 10003 O SITE: 17,500.00 SQ. FT. = 0.4 ACRES >- ZONING: R-40 Z COVERAGE: ALLOWABLE: 3500 SF O W EXISTING UTILITY POLE S 40d 28 00 E ACTUAL: 3264 SF or 18.6% H Z • SURVEYOR: RODERICK VAN TUYL, PC GREENPORT NEW YORK Q LICENSE # 25626 Q laJ O DATED 1 / 8 / 88 O ;n Q nC O ZONE X / LOLC"ATION MAP` zEXIST. TREE z RierOr% O '�'�JRONT YARD SETBACK ; ZONE ,4 \�\\�;.. 9 z X15T. TREE / - j i/ (EL: \�\\ `o Rd O PROPOSED ; RcJ I G ' %i�!; �� ENTRY � � ��� W II PORCH /!// l�l/Nl�l GOND //, /j FL-00 ADD I T �� \ w REMOVE EXIST // % ' / / / <; \\�\, \ o c� GONG. WALKY4AY — " \\ \\ 3 N— 2 X3 BLUESTONE ,// % !% �/ , /'-' \ ' o STEPPING STONE o V U VERIFY LOC. OF % a EX15T. WELL // "" i, /j / , /!/' ;�/ \ �\\\\�. \\ \\. y 93 101 / //, /i :\\\\.\ \\.. ,�\\ �a / /% /,Em//�//// / /�//.�/ ��� \�:\ \ �\ \. SITE r REMOVE , , , .EX15T. j �� '//�/ / REAR YARD SETBACK:'/ /i/ ��FLAGPOLE "/; CL / / PLANTS /�/ j' NEW DECK 05 Z • c /�/� / AREA t t 'EXI5TNG GONG. DRIVEWAY d• :// / �, ,r / ,% / ; -� a y oos Lu s xnz a EX15TING;/ �'�,ui IJ-1 REMOVE EXIST. GONG. Q N D u) EXIST. LT WAL Y m / i = W . 'n 0 v I AGGESSSORY o O TO �AIN jBUILDING/ N= co in • ST. D � // V�"� ` -------- ----- ---- - ------------- NEYIU6ROUNDELEGTRIGTOASSESSORY LDINF'------- ^, r. IUD ity Or urSAROUQ EXISTING Z OIL a PROPANE TANKS UnA MO�T EXIST. FENCE N 40d 28' 00" N PROJECT NO: 0601 DRAWN BY: UT SEE rL Ar' N CHECKED BY: SCALE: 1" = 109-0" NS DATE: SEPT. 12, 2006 SCALE: 1" = 10'-0" SHEET TITLE: SITE PLAN SHEET NO: FINAL DRAWING SITE DATA SCTM # 1000-26-3-3 PROPERTY: 345 DOUGLAS ROAD ADRESS ORIENT NEW YORK OWNER: NINA ESHOO Y 50 EAST 10th STREET New York, NY 10003 SITE: 17,500.00 SQ. FT. = 0.4 ACRES 0 ZONING: R-40 II COVERAGE: ALLOWABLE: 3500 SF W ACTUAL: 3264 SF or 18.6% EXISTING UTIILITY POLE I�5.00 5 406 28 00 E SURVEYOR: RODERICK VAN TUYL, PC ' _ GREENPORT NEW YORK Q O LICENSE # 25626 Q 0 Q p DATED 1 /8 /88 ;n O O O (n)- C A 0""Joffik m M 0 OXE EXIST. TREE L 06k Lu Q = ��er z O \\\ rd RONT _ /i RD 5ETBAGIG �O X15T. TREE /// / /!%/ /%;%:%;/ \\\ 9� < o, V ' PROPOSED /�; /,/ `: �RES I DE1�G /r,/ Lu ENTRY W/NEW 5EC.,0N��i W Lu /FL_OOR ADDITIFORCM K, ° z I� \.:< REMOVE EXIST GONG. WALKW WAY \�\� ' • 21X3' BLUES NE STEPPING STONE %;,j;/� '�;' ' ./�i/ /i// //''' �� \ :\\\ ° o O ; '�. /r �,,/ / \. \ \:\:, ;� ,•' ,. . mod+ VERIFY LOG. OF .,; �` �\;\ EXIST. WELL / / /!; \� SITE REMOVE REAR YARD 5ETBAGK ��\\, ;`\,\ Y,. �\ EXIST. FLAGPOLE61 — / PLAN NEW DECK AREA AN/1 ' TNG GONG;EXIS DRIVEWAY ° // ,/ i; �oQ M°APPRO ED AS NOTED L16 l DATE: B.P.# 3a5c �.. W 1i. FEE: m n z ° - - - tu REMOVE EXIST. GONG. WEN OUMPOOR /;EXISTING/ L ui EXIST. LT WALKWAY I AGGESSSORY _ NOTIFY BUILDING DEPARTMENT AT Q N�w TO REMAIN m ° ° p, %%BUILDING% , 765-1802 8AM TO 4PM FOR THE W an �O Q • ° • ° (°< • a ° � / „ O FOLLOWING INSPECTIONS: DETAI'1 STdr4t! l.'PiTER R P' N sT.s %''/�%%' 1. FOUNDATION - TWO REQUIRED U"� Q • r�rr cTRIc To LDIN6 / O PURSUANT TO SECTION 45-10^ --------- -------------- --------- — ---- - --- -- -------- //// ;% ' - FOR POURED CONCRETE �, ,, �+ 2. ROUGH - FRAMING & PLUMBING �!'Ti TOE i�C�Qr, V 3. INSULATION -6 4. FINAL - CONSTRUCTION MUST _ 111 D BE COMPLETE FOR C.O. AP'PWX.LOCATION Q ALL CONSTRUCTION SHALL MEET THE �� REMOVE EXIST. (Il� FENCE G (sl AG UNIT REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR __ OF DESIGN OR CONSTRUCTION ERRORS. ,• ' " I-1�.00' CERTIFICATIO"J OF N 40d 28 00 W NAILING &I CONUECTIOIIS � �, 4 COMPLY WITH ALL CODES OF REQJIdED. NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF i SOUTHOLD TCY.'N ZBA SOUTHOLD TOTN PLANNING BOARD PFYOJECT N SOUTHOLD TOV'N TRUSTEES 0601 N.Y.S.DEC DRAWN BY: UT t PLAN, 5,03D MINT, A SCALE: 1 = 101-0" I ComPLY WITH CHAPTER" :I�i" CHECKED BY: OR FLOOD DAMAGE! PREVENTION NS OCCUPANCY USE IS UNLAWFUL SOUTHOLD TOWN CODE. DATE: WITHOUT CERTIFICATE SEPT. 12, Zoos SCALE: OF OCCUPANiCY PF F IMaING SHEET TITLE: ALL CONSTRUCTION SHALL ALL PLUMBING WASTE 1MEET THE REQUIREMENTS OF THE &WATER LINES NEED CODES OF r4cr-W YORK STATE. TESTING BEFORE COVERING y SITE PLAN PLUMBER CERTIFICAT10,V ON LEAD CO"�sTEr BEFORE CERTIFICATEO,"06&1; A;Ncy SOLDER X'T ty WATER SUPPL YS T �f C1A','VOT SHEET NO: EXCEED,^/10071c;LElD WIDERN1RITERS CERTIFICATE REQUIRED FINAL DRAWING NOTE: REMOVE ALL EXTERIOR NOTE: REMOVE ALL EXIST. FLOOD LIGHTS WINDOWS JUST PRIOR TO NEW WINDOW INSTALL- - REMOVE CLOSET � REMOVE EXIST. �[ t STORE CEDAR HANDRAIL L LINING FOR REUSE EXIST. I 0 REMOVE bl BD GL6 3 II XI 5TINCG EXISTING I EXI5TINCG z Di'�OOM = � BEDROOM CD BEDROOM REMOVE GYP BD GL6 EXIST. REMOVE GYP 113D GL6 REMOVE CIL05ET ORE CM AR I I REMOVELWALLPAPER z LINING FOR REUr✓E REMOVE REMOVE DOOR � STORE FOR L O O I REUSE OS — — — STORE FOR EXIST. 74 — — O o I REMOVE ALL EXIST. I RexE REMOVE GYP BD GL6 PATH — — C PLUMBING FIXTURES REMOVE ALL TILE, EXIST. IEXIS . ) AND PIPING I TUB TO Q EXIST. CLOSET 5-r• A YPLUMB. FI)CIIJRES, REMAIN — — — — — _J HALLO 5ATH — tWALLP GAB. I � w / TI IT i _ I e _ / I,P STORAGE aL l lA I co ~ DN EXISTING CHIMNEY I I o I� WAIN IR I ) TO REMAIN I z 0 IN — REMOVE EX11T.COW.,. O WALKK^Y 0 <—TEMPORARY SUPPORT 0 AT EXI5TIN6 HEADER O EX 15T I NG I Z v NOTE: ALL EXIST. DOORS ROOF DECK I (/ W 7;zf=mnvr_ SET TO BE STOCKPILED ANDCD 4 STORE CEDAR LABELED FOR FUTURE USE I I IXI ST)NG •` ININ6 FOR REUSE REMOVE ALL EXISTING DECKIN6, I I REMOVE EXISTING EXIST. O WATERPROOFING, PLYWOOD I I I BAY WINDOW, ENTRY LIVING/DINING AREA SX15•'r1N�7 AND EXISTING FLOOR JOISTS III �51�IITE rR D�G ALL INTERIOR FINISHES TO REMAIN EXCEPT CEILIN65 IN ALL AREAS REMOVE ALL EXIST. BEDROOM I I I AFFECTED BY NEW SECOND FL. DECKING DOWN TO REMOVE ALL EXIST. WALLS REMOVE EXISTING HANDRAIL I I (TYPICAL) EXIST. DECK JOISTS ROOF, WINDOWS 4 DOOR5 k I I REMOVE ALL EXISTING FLOOR'G DOWN TO NOTE: ALL DOORS TO REMAIN OAK OAK5UBF OR I I I UNLESS NOTED OTHERWISE i I I I I I I 19T. WATER STORAGE TANK Z. EXI5TIN6 CHIMNEY TO REMAIN I MG I I N Q ROOM ElI HW � -� �• c � I III _J . � w REMOVE EXIST. I a Z LLX I ST I NG HANDRAIL m w- w M g EXISTING 6A �X 15T I NG �G I TG N I I w. a N 0 � X 1ST• I DOOR AT TIME OF INSTALLATION LAU I CDR EXISTING GEILIN6 TO REMAIN ROOT= I I II OF NEW DOOR EXIST. GL6 �X 15T1 NCG TO REMAIN I cn cn REMOVE ALL EXISTING ROOFING, I ( II I PLYWOOD SHEATHING, 4 RAFTERS I CGARA&E IST. SHELVES EXISTING GEILIN6 4 ALL TO REMAIN REMOVE EXIST. RANGE, I I I DN REMOVE EXISTING I I FINISHES TO REMAIN � COORDINATE 4 NOTE: PROTECT EXISTING I STAIR 4 LANDINGS I II REMOVE �"1 �� ARCHITECT HEATING EQUIPMENT DURING I AINE _- DEMOLITON AND CONSTRUCTION RA4EX. K OF T I I REMOVE EXIST.— TOILET 4 WALL- REMOVE 5 �—REMOVE EXIST. PAPER IN PWD BATH ��� DOORS d STAIR DOWN TO H- H- I� E-+ BArH V �I- 14 H � I I DECK STRUGT. EX. VANITY 'rQ REMAIN, IL REMOVE EXIST. HANDRAIL U EXIST. REMOVE EXIST. DECK I DECK AREA REMOVE EXIST REMOVE ALL EXIST. PROJECT NO:I I I 0601 GENERATOR AND DECKING DOWN TO REMOVE EXIST. ENCLOSURE EXIST. DECK JOISTS I TRELLIS — I DRAWN BY: UT C - - � NS DATE: Sept. 12, 2006 DEMOLITION DEMOLITION 1/4�� = 1v - owl SHEET TITLESECOND FLU-Kim PLAN Ir= 1 0 Km% S&T F' EL 4 0 ff-um- ft" r Kmft 0 P L AM IM SCALE: 1/4" = 1 -0 SCALE: 1/4" = V -0" DEMOLITION FLOOR PLANS SHEET NO: FINAL DRAWING Vo op REMOVE EXIST. FIELD VERIFY WINDOW 4 INSTALL — NEW WINDOWS— — El �- - N OJe o o` I IDLK FDN WAL �"L +�+ " BELLOW EXIST B I I I -° z co v ( EXISTING I ACCESS WAY Z - ( NEW GONG ELK" OC I I IT SST UK LL. — � FDN WA w/24 X 10"D - O GONG. FTS UNDER 0 r VERIFY Yv La I ILi EXISTING STRUCT. I ARCHITECT O I I EXIST. FM WALL �, I EXIST. FDN WALL Q FOOTING, (TYPJ 4 FOOTING (TYPJ I Q i ICIEXIST. 8" X I6' I �j GONG. ELK PEIRS EXIST. DECK JOISTS EXIST. ACCESS^ EXIST. STL COL --- HATCH -h co z20 Q v�IFY FoonNG SIZE �POVIDE 3'X3'XI'D IF O Q I I I REQUIRED --1 0 NEW GONG BLK NEW 3 1/2"d STL COL FDN WALL w/24' X 1000 L J GONG. FTG, UNDER NEW I I I L Q PI ADDITION IEXIST-2 FJ. 0 16" OG p =ry I I " F--EXIST. 5TL COIL I I I Z 4 CONG. SLAB W/ 6X6 IOAO REINF. W "CD 4 I I ON G,RADE I FX 15T I I`4G GR�I�IL 5�'�G� O IE S TO GONG.I I EXIST. COW.,. SLAB T LAB PIERS NEW R-IQ GATT INSUL I I I I I FIELD VERIFY EXISTING EXIST THICKEN SLAB AT I I OIL � I I C RAkNL 5fi AGE PERIMETER WITH TANK EXIST. GONG. SLAB TOP d B B R I I RETO MAIN I I NEW R-19 GATT IWWL 6'-8" b'_8" EXIST. 2X8 FJ. o 16. OG I O �--- I — � � 3-2x10 �`y�� 8-2x10 I rOOTI ( ) II I I I I I I II ER n Z. OMdX9PI � I I6"dGONG. PI EN QD 61 y A O 33 n Q•PI 36" D1EPYCAL) EXIST DECK PEEP (TYPICAL) � g I T STRUCTURE I I I I STRAP G,IRDER TO o o EACH PIER (TYPICAL AT ALL LOCATIONS) W J• Z EXIST. DECK JOISTS = W• M = N g EX15TIN& � W• aN � M &ARAGE 5LAB 2)QO P.T. DECK JOISTS 0 O Q a cnco• EI �,� I<—EXIST. FDN WALL I -j 4 FOOTING, (TYPJ L ( ( I }4 Cl- VERIFY DECK STRUGT. .. WITH ARCHITECT NON-STCOL. A RUGTun " 3-2aCIO MIN. B-2XI0 a,A Y 6'-8" 6'-8" P OJEC ' O: 0601 20' DRAWN'BY: NS EXISTING, STEPP j NS EXIST. DECK STRUCTU DATE:RE SEPT. 12, 2006 (ASSUMED LOCATIONS) 11491 = 1' - 01119 SHEET TITLE: IMP Ulm M I v FOUNDATIO N Ill F00um N "AT P L SCALE: 1/4" = V -0" PLAN SHEET NO: FINAL DRAWING 00 4" 8" 50 CASED COL W/4-2X6 PLT POST. P ND ROVIIDDE ANCHORS GASP W1 1XIX4 BASE ('TYPICAL) NEW WINDOW NEW WINDOW IN NEW WINDOW REMOVE EXIST �t IN EXIST. OPEN'S NEW OPEN'& IN EXIST. OPEN'& RAILING Z .9 EXIST. 0 Op G1 0 LOSiET G �' O IST. 2 X 8 F.J. ®Ib" O.G. Z WI CA NEW 2 EX 15T1 NG r (TYPICAL AT ALL F PATCH FLOOR BEDROOM M. B IN THIS AREA EXIST. WD FLOOR ' IF REQUIRED EX O 9 �o HALL E— O OFFICE Exl T W FLOOR — x- (FORMER BEDROOM) lex O - �z EXIST. WD FLOOR O - EXIST. NEW TILE DECK EXIST. DECK TO REMAINEXIS 0 AIIII 5INTRY DppR MREMOVET. EX Lroco AT EXIST. TUB PROVIDE DEGKIN& INFILL Q i- OPENING 2 OVER EXIST. STRUCTURE EX 15T. BATH 1 11 3 EXIST. dj EXJ^ID FL A - L xal 3-2�xIo NF 3-2 NEW TOILET AND EXISTING PEDESTAL SIW TUB TO Z D35T. STAIRLI - _ REMAIN O T I EX EXIST. O O 0 E 0 .G Q 0 2X4 m AlPOST EXIST. CABINET I N Q. O `} OPEN TO ABOVE EXIST. HATCH �X4 TO REMAIN SPADR E POSIT O — 3-?.X8— - - 3-2X8 EXISTING 3-2X8 XX Z CHANGE IN CEILING FIREPLACE W W I^ 1� � ■ L AXIST. 2 X 8 F.J. 616r O.G'.. O 0. SISTERED NEW 230 / p- O 0 I I 2'X2' T NE �1 cTYPIGAL AT ALL F.J) PA VMS INF. O N N r �X15TING x = x = X15TING LIYINC� REA � x � X DINING AREA in EXIST. WD FLOOR E—CASE NEW BEAMS W/ � IYpF� O 8" 50 CASED COL W/4-2X6 EO ry IX POPLAR WITH GROWMI ry MOULDING IN THIS AREA PLT POST. PROVIDE ANCHORS MOULDING AT GL&. TOP AND BOT WI VIM ffl . O'-O" GAP W/ IX4 BASE TYPICAL) _ I tV tV O E 1 X X 2 1 6- ■ 6_8 6�_811 'HEADER EXIST. „3j � CASE NEW BEAM W/ MIN. zz IX POPLAR WITH GRDWN 6 MOULDING AT GL6. EXISTING 4 NEW NEW `r Z IREPLAC' POST pO T 3-al/2"LVL 4-1 7 - - - -POST 777717 tea• Mg p I 2 1 N I I Jam• Qa � MEGH ROOM w J• = Q � x PROVIDE 1/2" PLY- I I W• a C4 a ��Q EX O ,,,,• N = V O WOOD SHEAR WALL 2 �X15TING EX15TING I I I I I a F• cre o KITCHEN LUND� p� EXIST. WD FLOOR I I I I i N N NEW &ARA&E DOOR AT � I/2" PLY- j"� FLOOR INSTALL NEW FAUCET— PROVIDE _i EXISTIN& OPENING -VERIFY ; ® X 1ST I NG WOOD SHEAR WAIL AT EXIST. SINK I I ry ® V Q EXACT SIZE PRIOR TO 4 NEW 5/8" GYP INSTALL NEW G.T. 4 BASE EXIST. CONCRETE ORDERING 43 L 6ARA&E BO FIN. I PREEM,OI/0E EX. CABINETS TO MATCH F / I - DRIVEWAY X EXIST. GONG. SLAB 4 WALL4 IT i O IST. ItE X _ I NEN lwoyi r � PANELS W, .\,. � I"DBL DOORS NEW OPN 6 XIST. ATTIC, 15TIN6- " Tf01 III I I I I m EX 0 8 = •yC � Rfir`:: 7rE 6 STAIR REMAIN EXIST. ELECT. LTO ui �`OO I CH Ilk zz . @ NEW WINDOW NEWINDOW - 514ilk r% IN EXIST. OPEN'S IN EXIST. OPEMIS IZZ � PROD T NO: NEW OUTDOOR EXISTf'. z I6 L DECK 0601 eSHOY HANDRAIL I DR-AWN BY:STEP UP Q ( / NS EXIST. GONG WALKWAY 5/4 X6 MAHOGANYJ I I N DECKING ON 2X6 PT � NS DECK JOISTS ®Ib"OC DATE: EXIST. STEP ON SEPT. 12, 2006 • 12'- " VERIFY 1/4" = 1' - 0" SHEET TITLE: 4" 4" FIRST 28'-I" 52'-6" FIELD VERIFY op FLOOR PLAN SHEET NO: IFIR' S"l- FLOOffimm' PLAIM-1 SCALE: 1/4" = 1' -0" FINAL DRAWING V O 4'-0" 30'-"i" 4'-0" 10'-8" 3 1/211 V-2 1/4" --5 I/ " 14�'-'7 1/4" 5 1/2'" RECESSED MEDIGI NOTE= PROVIDE NEW 3/4" PLYWOOD SUB-FLR CABINET ON NEW DBL 2X6 FL JSTS COORDINATE IN AREAS SHOWN SHADED EXACT. LOG. iv OF WALL -T71 ABOVE FL. 0 O O volDLj s 3 0 _ .� 1 = -� m I z w B I121 1I O g MAS R N I I-OOR I m o _ I 2X6 TIE AT EA - Q 51DE or- 2XIO RR co W/ 2-5/6" MB TYP Q .0 .EACH TIE, CASED W IX POPLAR O I w BELOLl W It REUSE CEDAR IN -cw %r fANDINv;% .- WALK-IN CLOSETcn � SHELF 5_�2 O K E ANdF eL - rt � I — '/ DIN n g _ HAI I .k ROOF w a m N WOOD LOOR BELOW I m 0 \ I O OPEN TO L.R. BELOW I GHANSE IN d _ �•+ N CEILING cv m W � O �� m I 4- 2 of 5Vloll 2X6 TIE AT EA tau 51DE OF 2XIO RR BEDROOM #1 M B R YV 2-5/6" MB TYP ®EACH TIE, CASED YVOOD FLOOR W IX POPLAR K O - COORDINATE I I m EXACT. LOG. OF WALL -T 14 I G w ABOVE FL. 0 m cn I,_4„ n I otS Z STORA6E N sHtPL 12 - - - - - - - - Jg. x (V 4 ry LV -J CC Q in N 8' G W• a = M C1 � XX 3 1/2 8'-2" N 5 1/2" 14/-7 I/4" I'Je 14-1 1/4" 5 1/2" 00, PORCH BELON ATT I O < EX15T FURNACE STORAG TO INg�i 7, NEW 5/4 PLYWOOD SUBFL ' �O Mr - - - - - - - - - - - - — - -- - - - - - - - - - - - - - - - -ROOF PROJECT NO: 0601 DRAWN BY: NS MIEUKE ' NS { < BATE y SEPT. 12, 2006 LE: 1/4" = 1'I . 0" SHEET TITLE: SECOND FLOOR PLAN FMIM N E) F L 0 P L SCALE: 1/4" = 1' -0" SHEET NO: FINAL DRAWING V 0) 4'T'-O" m _ Y — — — L I 1 O I p 3 co - I z ! I I Ioo, B ( 411251.0VFMT -- — 8 he mpkoq 1 - 0 L Wo I I 711 m 4110oxic I I I -- - - -- ' O -21RIri m 0 41 m A �b8 T N O w, Q>zQ 00 71 00 L I ; O 1 I I I I I I I' I o -- op I ALUMINUM W TM - M ff 1 I I - _ I i - _ — -- Z. _� 1 _ - - - - - — - - — co � g 4 EXIST. I _g�� ° cq W —� z I I I = az' u- I If 4 �= � UJ• c� � u; a LLI• N � � IIup Q iI. •nor Q ot IV N ROO N �' .. 4 UL IV RO NO. 0601 ALUMINUM &UrrER DRAWN BY: NS CHECK S J TE: SEPT. 12, 2006 A E: 1/4" = I - 0" SHEET TITLE: ROOF PLAN RuuF PL AN SCALE: 1/4" = V -0" SHEET NO: FINAL DRAWING A B 9 9 IX6 RAKE BD W17H IX3 - TRIM WITH 5/4 X95 FREIZE 4 BOARD iV EXTEND EXIST. CHIMNEYS 2'-0" ABOVE NEW RIDGE LINE - APPROX. 4'-6" ,[ 1-2 L NEW CEDAR SHINGLES ON 5/6" PLYWOOD 4 BUILDING PAPER 3 G� Z SECOND FL TOP OF NEW PLATE Z NEW ROOF STRUCTURE O 12 AT EXISTING GARAGE �a IX6 RAKE BD WITH IX2 TRIM WITH 5/4 X6 FREIZE p BOARD ISTIN6 0 ELECTRIC, RISER TO BE EXTENDED ui SECOND FLOOR 01 3: TOP OF NEW SUBFL BUILDIN&PAPER TOP OF EXIST. PLATE Z Q ALUM. GUTTER (TYP) O - ON IX6 FASCIA r LU O =V a Q > lu Li O __-- - - W GARAGE DOOR Z IN EXISTING OPENING TOP OF . SUBFL.T FLOOR 19 W CD NEW WINDOWS IN NEW ._ 6" 50 CASED GOL W/5-2X6 OPENING (SEE PLAW L O PLT POST'. PROVIID}{E ANCHORS TONE PAVERS GAP r 40BAW5I (TYPIGA[F ON GONG. SLAB AT NEW ENTRY PORCH WEa m I tLEVATIOR SCALE: 114" = V -0" EXTEND EXIST. CHIMNEYS A B 2'-O" ABOVE NEW RIDGE 9 9 otS Z. LINE - APPROX. 4'-6" NEW ASPHALT SHINGLE ROOF V3 Q ON 5/4" PLYWOOD 4 500 4 ROOFING FELT (TYPICAL) (V W J. Z DW. L � IX6 RAKE BD WITH IX5 a N TRIM WITH 5/4 X 6 FREIZE W• N BOARD c0icn N N- TOP OF NEW PLATE 5/4 X4 y J J J OBUILDINS PAPER J J J CASING (TYP) 1 12 mq- XMI 3 IX6 RAKE BD WITH 1X3 `-ry:;«:.::-- TRIM WITH 5/4 X6 FRIEZE 01 BOARD � TOP OF NEW SUBFL 1-g STOP OF EXIST. PLATE GUTTER (TYP) 0601 8 50 CASED COL W/4-2X6 .a: 05T. PROVIDE ANCHORS ';NOD..>; ;:<:"s. >'< >;:.::: PLT P , .. .,;.: ... y �::r�; 4: EXI 5L. EXIST. 5L. EXIST. SL. REMOVE EXISTING SIDING DRAWN BY: TOP AND BOT W IXb 4 X-3 . . II II - :`,• ,: >: f � ::: GL. GL. POOR GL. OR AND PROVIDE NEW CEDAR NS GAP W/ IX4 BASE�TYPIGAL.) _ <Y >; SHINGLES - 5 1/2 TO - WEATHER ON EXIST. ;:" NS SHEATHING (TYPICAL) IN EX. OPEN& WA X4. RECESSED DATE: PANG. SEPT. 8, 2006 TOP OF EXIST. SUBFL. EXIST. GRADE EXIST. GRADE61W 1/4" = 1 -0" 16"d CONCRET PIER ON - 6X6 PT WDOD LATTICE PANEL BELOWPRIDST E NEWCK Ar5�/4 x 6P SHEET TITLE: g12 5G2 X 10"5 FOOTING m POST FASCIA BOARD AS REO'D MAHOGANY DECKING ON EAST & c�Y AU EXISTING STRUCTURE. WEST LEVATION At EtLPEVATION l=M%AJ — SCALE: 1/4" = V -0" SHEET NO: FINAL DRAWING EXTEND EXIST. CHIMNEY IXb RAKE BD WITH I X5 C 2'-0" ABOVE NEW RIDGE TRIM WITH 5/4 X6 FREIZE 1 Q LINE - APPROX. 4'-6" BOARD �RID&E VENT 0 N D 10 SECOND FLOOR i TOP OF NEW PLATE 0 3 CD cl) z 4 z CEDAR SHINGLE 51DING 12 SECOND FLOOR 4TOP OF NEW SUBFL 0 TOP OF EXIST. PLATE ev LUA `..;. ;..� .;:, 1.:;�`} �': >Y. : -,,...;9 .tir,:; ., r:S'!'y�.,`:{' .;' ':� "V1, 8 50 CASED COL w/4-2X6 PT POST. PROVIDE ANCHORS J : .:;.:.;. TOP AND BOT W IX6 d IX'3 } � GAPBASE IG NEw wlNDoHS NEW WINDOWS IN EX. OPEN'& REGESSED� iv FIRST FLOOR {� IN EX. OPEN'G PANEL TOP OF EXIST. SUBFL. 0 6X6 PT WOOD POST O REMOVE EXISTING SIDING OUTDOOR SHOWER ENGLOSUR1,E OG DOOR I z AND PROVIDE NEW GEDAR 4X4 POSTS w/IX6 CEDAR Tow EXISTING DECK AND IN SCREEN SHIN&LES - 5 I/2" TO "V" &ROVE WITH IXI LATTICE STEP WITH NEW DECKIN& PAS- I6"d CONCRETE PIER ON W ON 52" 50 X 10"D FOOTIN& WEATHER ON EXIST. (TYPICAL) SHEAT'HIN& (TYPICAL) L O Lim "h0m "TH EL"mVAfl0lftlmm SCALE: 1/4" = V -0" C 10 ad z- v� a• Ofc" M T IDLE VENT J c n T Z w �• � Q2� U. D � W• c=i � u; � 10 Q C4 N � W• N � TOP OF NEW PLATE I'-D° 2Xb RAKE BD WITH IX5 TRIM WITH 5/4 Xb FREIZE BOARD NEW ASPHALT SHINGLE ROOF d) ON 5/4 PLYWOOD it 500 rF` y ROOFING FELT (TICAL)YP s'�, �' „ B� •y BUILDINS PAPER 12 4 may` �� ULr9�3 — — — — — — — — TOP OF NEW SUBFL . { ;fix;'." r:�: ., :_ I '�3'�<•>;� I'-3" TOP OF EXIST. PLATE 77.1 8 50 CASED GOL W/3-2X6 PROJ T NO: 8" SQ CASED COL W/4-2X6 'C ` J' : :`{` PT POST. PROVIDE ANCHORS _ 06 ' 9:$;:::::;`,:; TOP AND SOT WI IXb Ix-3 - PT POST. PROVIDE ANCHORS O GAP W/ IX4 BASETYPICAU DRAWN BY: TOP AND BOT W I X6 3 X3 :; ;�`�; �::;: .> i�${•::::;:�� I .. :. IT}{ I - f" O GAP W/ IX4 BASE ('M'IGALJ � tl�>�>;:::: .�.�,. ��<>�» ,;�:::::^:': :.{ Y ��{';:' O ON COW.,. ONE PAVERS ON GONG. SLAB AT -- = NEW ENTRY PORCH PANEL . oloWs (V TOP OF EXIST. SUBFL. DATE: IX 10 FASIGA 10 FAA55 C, I N, SEPT. 12, 2006 6X6 PT WOOD POST 'm7 A E: I6"d CONCRETE PIER ON NEW GONG. BLK FDN N 512 X 10"D FOOTING LA IG PANEL BELOW \--EXISTIN& DECK AND FIRST FLOOR EXT. YVALLS 1/4" = 1'-0"p 5QWALL i FT& UNDER 4"d CONGRET PIER ON 8"X 24" SHEET TITLE: (TYPIGALJ FA I BOARD AS REQ'D STEP WITH NEW DECKING q PROVIDE INEW CEDAR EXISTING CANTILEVERED I m SG2. FooTIN& (TYPIGAQ " WALL (THIS AREA ONLY) � SHINGLES 51/2 TO WEATHER ON EXIST. NORTH & SHEATHING (TYPIGAI..) SOUTH Ate• � `�'�' ELEVATION INORTH ELEVAmpl'"K014 SCALE: 1/4" = V -0" SHEET NO: FINAL DRAWING RIDGE VENT SOT OF RIDGE NEW 2XIO RR a 16"00 YV/3/4" PLYWOOD SHEATHING, YV/ ASPHALT 2-2X8 HEADER SHINGLE ROOOF AWNING WINDOW E 1/2" GYP BD CEILING ATTIC 12 14 W/ 5/4 X 4 CASING 2X6 STUDS alb" W 6" BATT INSUL 5-2XIO HDR TOP OF DBL PL Y 5-2XIO HEADER I-O 2X8 CJ a 16 OG _ W/R-50 BATT INSUL. t 0 CASEMENT WINDOW O �I IAI REUSE CEDAR ON. ALL NEW 2X6 STUD' e16"OG W/ 5/4 X 4 CASING iV I Xr-r � WALL5 4CLG!� ` WITH 5� S %THIN¢_ 2X6 STUDS a 16'OG v HALL CASED OPENING co W I� GATT INSUL +� � WITH 5/8 PLYWOODR-Q BEYOND NEY _ O Z SHEATHING ry Nr- � ALK-I I`I, CLOSET -�O' NEW 2XIO RR a 16"OC 12 r STAIR HALL o I/NEN soL #OqR� "/4 PLYYVDOD 4.. WALL-5 d GEILLIN65 12 SHEATHING W/ASPHALT 0 SHINGLE ROOF q 0 4 STUD WALLALL NEW 6' BATT INSUL Q 2ND F1aGOR TO RAFTERS SHELF BETYVEEN FLOORS 2ND FLOOR TOP OF SUBFLOOR7 TOP OF SUBFLOOR _ TOP OF EXIST. PL TOP OF NEW PLATE Q 4-2X8 HDR 1 5/4 x 8 FRIEZE BOARD 5-2X8 HDR CASED 2X8 GJ alb"OG YV/ R-50 BAIT INSUL I_3 EXIST. I'm }� IN IX CEDAR "AZEK EE OARD• 016 FL JOISTS NEW DB1L 2X8 FLOOR JOISTS IN THI5 oAREA ONLY CEILING alb OG . IAI O Aw INX CEDAR CASED NE rY DOOR �X I sT. NEW DBL HUNG WINDOW �j F CU r ENTR'r EXIST. S uN 4 EX 15T. IN EXISTING OPENING W/ _ = Q FORGH H A L NEW 5/4X4 CASING �p T-f l'� BATH CC) EX 1 ST I NG MXIST. WD FLOOR O EXIST. STAIR W/5/4 EXIST. L I N. CLOSET _ _ z 2 SGt BLUETONE PAVERS NEW CHERRY om'°`Y T CLOSET 1ST. BEALRIN6 K44EK CEDAR SHINGLE W ON 4" GONG. SLAB AT AREA OF EXIST WALL TO BE REMOVED WA�,1. EXIST. TUB SIDING �/ Z IST FLOOR L IST FLOOR LLI TOP OF EX. SUBFLOOR TOP OF EX. SURF \ •:•°ice \ .\ \ O \ EXIST. FDN WALL OIGTGH GV�l1, SSG NEW R-la BATT INSUL SPACE \/RAYC \/\ EXIST. FDN \/\ EXIST. GONG. SLAB 1ST. GONG. BLK TYP. AT CRAWL PIER YV/3-2X8 GIRDER / \// SPACE / 08" m mim 00" ING Sr% '"m Al"k m"m r' m / / / \\/\\��\��\ \\ \\ \\/\\/\ SCALE: 3/8" = 1. �.. RIDGE VENT atS Z N Q• "' o r � BOT OF RIDGE ;9 / \ wJ• wz 12 / / II it = LIJ- W) NEW 2XIO RR a I6"OC 4�— \ 2-2X8 HEADER. W/3/4" PLYWOOD / \ I I I I W• a in N M 5HINGLTM.EIN ASPHALT /ROOF \ 55/4 x 41rOA5ING Q I.,, to R-30 GATT INSUL / I - R-90 GATT IN5U1. N y. / / ATTI� 2X6 CLG JOISTS \ a WOO \ TOP OF DBL PL / / \ 8-2XIO HEADER EA LINE OF R00F—�' / 51 TI :n RR \ BEYOND / / e BTIE G \ �\ r ."t Tyr W IX POPLAR *5 �f �p IEN \ DBL HUNG WINDOW MBTE w/5/4 x 4 CASING / BATHSI LL BEDROOM t` O _ Q NEW WD FLOOR \ 2X6 STUDS a Ib"OC fd ' / NEW TILE FLOOR d� NEW WD FLOOR I/� GYP BD • ALL �' � r YVALLS d CEILINGS WITH 5/8" PLYWOOD I/2" WR GYP BD WITH SHEATHING 8' So CASED COL KM-=6 12 MOF WAINSGOATING 2X6 STUDS eI6" OG 12 NEW 2XIO RR a 16"00 PAOAC o.0601 PT POST. PROVIDE ANCHORS O W 6" BATT INSUL ,/ TOP AND BOT WITH IXb d IXB `F�- - NEW 5/4" PLYWD SUBFL q YV/3/4" PLYWOOD GAP W/ B BASE ( IX6 4 I m� W/ TILE FLOOR ON MUD NEW 6' BATT INSUIL 5HEATHING YV/ASPHALT BETYVEEN FL S 5HINGLE RDOF DRAWL BY: 2ND FLOOR R-50 BATT INSUL Y V N S TOP OF SUBFLOOR VAPOR BARRIER 2ND FLOOR TOP OF SUBIFLOOR CHECKED BY: TOP OF EXIST. PL 2X4 STUD WALL TOP OF EXIST. TE DATE: TO RAFTERS EXIST. 2X6 FJ 016"00 SEPT. 12, 2006 5-2X15 HDR CASE 2X8 GJ eI6"OG YV/ YV/NEW 2X8 515TERED VERIFY EXIST. HEADER EXIST. FADER I-3 IN IX CEDAR 'AZEK SEADSOARD" TO EXISTING (`TYP) 5-2XIO MIN. 8" CEILING N NEVV�PBL 2X8 FLooR JOISTS &UUTTER�dIA�EALADBD SCALE: NEW I/2 GYP BD CEILING a Ib o.G IN ITH 5 AREA oNLY " 3/8" = 1'-0" 1.I�IwI AT FIRST FLOOR GLGS SOFFIT (VENTED) SHEET TITLE: I`l r � CN D ON FIRST FLOOR ENTR"*r EX I ST i 1�G EX 1ST. EX I ST I N& S I7i�00M EXIHA�LLooR BEDROOM BUILDING NEW DBL HUNG WINDOW EXIST. WD FLOOR PATCH IF REO"D EX15T. WD FLOOR IN EXISTING OPENING EXIST. 5L DOOR TO REMAIN R SECTIONS NEW R-Iq BAIT INSUL EXIST. GYP BD B u I L KALLS To IN EXIST. 2X8 FJ. a 160 CC, TYP. AT FIRST. EXIST. DECK STRUCT. SCALE: 3/8" = 1' -0" IST FLOOR Y41 BFLOOR�AND VGKI NEW�3/4"X 6 MAHOGANY IST FLOOR FLOORI TOP OF EX. SUBFLOOR 4 SLOPE 1/6"/1' TOP OF EX. SUEIFLOOR SHEET NO: \ / / / / / EXIST. FDN WALL EXIST. MN WALL EXIST. GRADE y 7\ 7/7, N�E�W4GOy�NGx. BLKpFON / /� // /j/ / // // // // '•tt BELONW EXI��p WAL1.G PIER YN/-2-2XXB 61KRDER TTYIP.TAT CRRA.WI A / \ \ \ \ \ \ SPACE \\\\\\ \\\\\\ � 1ST. DECK STRUGT. \\ / \/ FINAL DRAWING s NEW 2XIO RR O 16000 14/5/4" PLYWOOD RIDGE VENT' SHEATHING YV/ ASPHALT 2-2XI2 RIDGE SHIN&L.E ROOF 12 ATTIC JI- AGE 12 R-50 BATT I �a - 2-2XI2 RIDGE Oww7 TI TIB A TOP OF VOL PLN_ pije 2X5 GJ 016" OG 8 M. TYP 3-2X5 HEADER YV/R-50 BATT INSUL ® TIE, CASED W IX POPLAR 1�ICIw1 NEW 2XIO RR ® 16"OC /I�`E `4 W W/5/4" PLYWOOD 12 -- - NPN MASTER DBL MJN6 wlNDow z Z SHEATHING YV/ ASPHALT HALL L.� DR�OOM = SHINGLE ROOF � NEN I LJ � W/5/4 X 4 CASING O NEW WD FLOOR BEDROOM 0 I/2 6YP BD o ALL p I— NEW YVD FLOOR WALLS 4 CEILINGS g" LL&.S t CEILINGS 2X4 57UD5 A 16" OG O ATTIC, SFAGE R-la GATT INSUL NV 5 I/2" BAIT INSUL 0 Q INSUL X6 TWpS ® 16000 VERIFY EXIST. INSUL OVER L040R Y BETHMN FLOORS SSHEATH/IN6 4 CEDAR HEATED SPACE. PROVIDE SHINGLE SIDING Z NEW INSUL IF REGV 2NV FLOOR TOP OF SUBFLOOR _ Lu "TOP OF EXIST. PL TOP OF EXIST. PL U) Ja EXIST. 2X6 FJ ® 16"OG EXIST. 2X8 FJ •16"OG Z O 4 GYP BD GL6 TO YV/NEW 2X8 SISTERED EXIST. GYP BD 0 REMAIN TO EXISTING, (TYP) WALLS TO REMAIN IX6 FASCIA WITH ALUM ��// TYP. AT FIRST. FL 1'�1� GUTTER 4 "AZEK BEADBD" EX 15T. NEW 1/2" GYP BD CEILING 1— SOFFIT 9NADR EX15TIN& AT ALL FIRST FLOOR GL65EXIST 2 X4 STUD WALL TH LAUNDRY ROOM EX15TIN& EX15T. EX15T. EXISTIN& HALE EXIST2 X4 STUD WALL _ > W/NEW CEDAR SHINGLE Q CEDAR SFIN6LE EXIST. YD FLOOR SIDING I I 6 � � SAUNAa T� PATCH IF REQ"D SIDING 0i O EXIST. WD d) EXIST. GYP BD YVALL EXIST. WD FLOOR FLOOR I z.1 �/�• LINEN NON TO REMAIN Y � NEYV. R-1a INSUL GL05ET Z INSUL IF SPACE W EXIST. 2X8 FJ. 0 16" OG WITH WD SUBFLOOR AND 115T FLOOR EXIST. CONC. 5LAB WD PLANK FLOORING 1ST FLOOR O Tr•OP OF SUBFLOOR TOP OF SUBFLOOR EXIST. &RAVE \\/\/\/\/\ GG X 1ST I NG P( IT LL0FN0i5m7 � . �2. EX 15T I NG EXIST. FDN YVALL EXI \ \ \ \\ \\ \\ \ EXIST GONG. sLAEB (THIS GR� Y�IL SR� G \\ GR�r�Y�IL SR��LG SPTPA ET GROYNE j\j�/\ r \\i\/\\/,\�j/\/\\j\\j\\j\\j\\j\\j\\j\\j\\j\\j\\j\\j\ /\\j\\j r,/ // / /,, / �. r�// \ caz• V/ M OI U I L I pi'mom G% S' PE to I"2-2XI2 RIDGE 10% W J' z 1' NEW 2XIO RR ® 16100 SCALE: 3/8" = -0" ' 1"/4" PLYWOOD D W• t� w c SHEATHING YV/ ASPHALT M ` SHINGLE ROOF W• a N ti Q H-• � � "AZEK BEADBOARD" AT EXPOSED CLS, N N j?ftjxAAN TpI ATx EA12 B MB T YP EXPO5ED RAFTERS �a 2X BLOCKING BETWEEN C�AI0 T EACH RAFTER 5-2XI0 HDR CASED IN IX CEDAR , I6N FASCIA 4 FRIEZE SGfi� N i�ORGf� BOARD WITH MAIN ROOF CHERRY 4 HANDRAIL v AS PER SPEC _ N 5/4 X 6 FRIEZE BOARD O.G. OR AS REQ. FOR STAIR BORED INTO TOP m PROJE NO.X IAND BOTTOM RAIL INVo N ISTI ' DRAWN BY: pi "d X 4 CAST all 50 CASED COL Y` 3-2X6 %X4 POPLAR TOP 4 NS W PT POST. PROVIDE ANCHORS BOTTOM RAIL PAINTED FLOOR LEVEL CHECKED BY: > TOP AND BOT WITH IX6 4 IX5 AS PER SPECS. GAP W/ IX4 BASE (TYPICAL) "r 5/4 X 6 MAH06ANY DATE: DECKIN& SEPT. 12, 2006 XIO P.T. DECK JOISTS •16" oG RAILING DETAIL SCALE: 3/8" = 1'-0" 5-2XIO P.T. RIM JOIST SCALE: 3/4"=1%0" SHEET TITLE: LATTICE PANEL AS REQUIRED EXISTING, GRADE \ / / \/ \/ \/ \/ / ���.�;� � \/\\/ �/\\/\�/ ��/� BUILDING \\/\\/\\/\\/\\/\\/\\/\\/\\/\\/\\/\\ \/\\/\\/\\��\� SECTIONS 6X6 PT POST YV/ SHEET NO: 16"d CONC. PIER ON 52" SQ X 10" D FOOTING, REINF. W/2 —#5 EACH WAY Li BUIL'u,' '611mu- a1=%m0T1u1N1_ SCALE: 3/8" = 1' -0" FINAL DRAWING WIND-BORNE DEBRIS PROTECTION FOROPEN OPENINGS STRUCTURAL RSV I EV BY STEVE MARESGA, PE FOR WALL OPENINC PROTGTION O 120 MPH -SGOND VlND GUSTS OT 188-0-7 NEST MONTAUK HIGHWAY, HAMPTON SA YS, NY I I a46 �/ �I SIGHT: ���1 SIMPSON LSTA - 20 GAGE FOIX 651 �20 1480 MAX MEAN I'IE�/�"�I�l ROOF H / RIDGE STRAP - ALL ROOF RAFTERS USE/OCCUPANCY ° 2 x 6 TIE a EACH RAFTER IN VIEW OF STRAP. CLASSIFICATION DESIGN CRITERIA: r � � I I ICE SHIELD UNDERLAYMENT S I II&LE FAM I L**r RESIDENTIAL SHUTTER ASSEMBLY REQUIRED - 24" FROM EDGE DE51 SN IN ACCORDANCE WITH AMER I CAN FOREST PRODUGT5 WOOD FRAME N.T.S. oil'FOR PANEL SPANS: O < 40 WIDE SPAN GON5TRUGTI ON MANUAL FOR I + 2 FAMILY HOUSE I HEIGHT PRESCRIPTIVE METHOD 23/32" APA SPAN-RATED 45/24 SHEATHING GRADE PLYWOOD I , ALTERNATE POSITION OF �_ �� i (OVERLAP AROUND OPENINGS 4 ) I 1 HURRICANE CLIP USE 35 O MAXIMUM GROUND SNOW LOAD - 45 PSF. ASSEMBLY: I I SIMP50N H3 ATTACHING STRUCTURAL PANEL: FASTEN TO BUILDING w/ ° I I FIRST LEVEL - 40 P5F. L.L. �. LIVING AREAS - 40 PSF. L.L. #lOx3" (w/ WASHERS) GALVINIZED OR STAINLESS STEEL - I I WOOD SCREW ® 16" O.G. 1 I e 51MPSON H2 HURRIGANE � BEDROOMS - 30 PSF. L.L. W ALTERNATIVE FASTENER FOR SHUTTER TO BUILDING: CLIP NAILED. FROM RAFTER TO STUD. - FIRE AREA WIND SPEED - 120 MPH #10 TEE NUTS ATTACHED TO BLDG. W/ #10xl-1/2 ( WASHERS) TYPICAL ALL RAFTERS I I MACHINE B 5OLT ® 12" O.G. W/ Z a�' 1 - 8d NAILS EACH END R�SID�NG�. SEISMIC DESIGN CATEGORY - B WEATHERING - SEVERE APA RATED PLYWOOD TO PROVIDE 8d COMMON FR05T LINE DEPTH - 56" EXTEND TO TOP OF TOP EXTERIOR"I°DGE OF ALL TERMITE - MODERATE TO HEAVY s�\ i BHEATH►NG. TYPE OF CONSTRUCTION DEGAY - SLIGHT J CONVENTIONAL LIGHT FRAME MOOD ICE SHIELD UNDERLAYMENT REQUIRED - YES I I GONSTRUGTION II ULTIPLE SECTION ASSEMBLY: I I/4" THICK BOLTS @ 2' OG GENERAL NOTES 11 II I I't, I - I. ALL WORK MATERIAL, AND EQUIPMENT SHALL BE IN 13. SEWAGE DISPOSAL SYSTEM AND FRESH WATER SUPPLY I I i 1 I ACCORDANCE WITH THE NEW YORK STATE UNIFORM SHALL BE DESIGNED AND BUILT IN ACCORDANCE 1 I I BUILDING CODE, AND THE NEW YORK STATE ENERGY WITH THE SUFFOLK COUNTY DEPARTMENT OF HEALTH. Z 1 I I I CONSERVATION CODE, I I AND LOCAL AUTHORITIES. 14. THIS STRUCTURE HAS SEEN DESIGNED IN 2. ALL CONCRETE SHALL BE STONE AGGREGATE WITH A ACCORDANCE WITH THE NEW YORK STATE ENERGY I I I I PLYWOOD SHEATHING MINIMUM 25 DAY STRENGTH OF 5000 P51 CONSERVATION CODE. 1 1 i t I TO OVER LAP BOX 1 I I I I BEAM - TOP + BOTTOM. 3. ALL LUMBER SHALL BE GRADE STAMPED DOUGLAS FIR- 15. ENGINEER TO BE NOTIFIED IN WRITING OF ALL Q I I I I 1 LARCH STRUCTURAL GRADE #2 OR BETTER. CHANGES PRIOR TO AND DURING CONSTRUCTION.. 4. PROVIDE DOUBLE HEADERS AND TRIMMERS AT ALL I6. ELECTRICAL AND MECHANICAL COMPONENTS TO BE H SHUTTER ASSEMBLY 1 DOUBLE TOP STAIR AND FLOOR OPENINGS, POSTS AND PARALLEL DESIGNED AND SPECIFIED BY OTHERS. 2 x 6 ®I6" O.C. PLATE PARTITIONS, EXCEPT AS NOTED ON DRAWING. Q I I I I I I STUDS I?. ALL STRUCTURAL STEEL TO BE ASTM A36 WITH ONE N.T.S. I 1 I 5. BRIDGING GOAT EPDXY PAINT. ALL FASTENERS TO BE ASTM W FOR PANEL SPANS:4' OR WIDER 'SPAN I �' I� I TO BE PROVIDED FOR ALL JOISTS AND A-325 BOLTS, 3/4" DIAMETER. FLOOR BEAMS. SPACING NOT TO EXCEED 5.0 FT. I ' I I I 6. ALL DIMENSIONS AND GRADE CONDITIONS TO BE 15. CONTRACTOR SHALL OBTAIN ALL PERMITS AND 23/32" APA SPAN-RATED 45/24 SHEATHING GRADE PLYWOOD I I I I VERIFIED BY CONTRACTOR(S) PRIOR TO START OF INSURANCE NECESSARY TO PROTECT THE ENGINEER (OVERLAP AROUND OPENINGS 4")) WRAP + NAIL 5TRAP AND OWNER. 2x4 STRONG-BACKS ® 24" OG I�, I�. AROUND SILL PLATE CONSTRUCTION AND ORDERING OF MATERIALS. TH15 AT ANCHOR BOLT 4 - 8d NAILS FOUNDATION HAS BEEN DESIGNED FOR A SOIL la. DO NOT BACKFILL AGAINST FOUNDATION WALLS 1 ASSEMBLY: I 1 I BEARING CAPACITY OF TWO (2) TSF AND GRADES UNTIL FLOOR SYSTEM INSTALLATION 15 GOMPLETIE. I I 51MPSON MST2'7 1 1/2" WIDE - 20 GAGE LE55 THAN 5%. CONTRACTOR SHALL VERIFY THAT 1). PREASSEMBLE PLYWOOD TO 2x4'5.. # lOx3" (w/ WASHERS) GALVINIZED OR I i METAL STRAP @45" OC. THESE CONDITIONS ARE MET. ALL FILL BENEATH 20. PROVIDE CARBON MONOXIDE ALARMS ON EACH LEVEL STAINLESS STEEL WOOD 50REW o 12" O.G. NAIL SHEATHING TO SILL PLATE CONCRETE SLABS TO BE COMPACTED TO q5% AND IN BASEMENT ( IF APPLICABLE ). POSITION NEAR 2). ATTACHING STRUCTURAL PANEL: FASTEN TO BUILDING W :ri;y; 2, 6d NAILS ® 4" O.C. RELATIVE DENSITY. ENTRY FROM HOUSE TO ATTACHED GARAGE AREA. 06 Z . c #IOx3" (W/ WASHERS) GALVANIZED OR STAINLESS STEEL = WOOD SCREW @ 16" O.G. `"`� £ 1. ALL HEADERS 6.0 FT IN LENGTH AND OVER TO BE 21. SMOKE DETECTORS REQUIRED IN EACH BEDROOM AND Q o 2 - #5 REBAR 'r`; '"'' `- ALTERNATIVE FASTENER FOR 5HIUTTER TO BUILDING: <::� :'P�: 2 x 6 SILL PLATE ON EAGH LEVEL OF DWELLING AS REQUIRED BY •-,"'.. '_t :,: i p� SATED, SUPPORTED BY DOUBLE UPRIGHTS, a.0 FT AND OVER Y r #10 TEE NUTS ATTACHED TO BLDr6. W/ #I0xl-1/2 ( W/ WASHERS) ':`; BY TRIPLE UPRIGHTS. ALL HEADERS TO BE NEW YORK STATE BUILDING CODE. -� .yQ0v MACHINE BOLT ® 12" O.G. `' SEE FOUNDATION DWG. ;:.stir; MINIMUM OF 2-2x8 OR AS SHOWN ON DRAWING. FOR DESIGN. ~ +'r ti E/8" x 12" A.B. @52" 00. 22. ANY ALTERATION, REPAIR, ADDITION OR CONVERSION TO w/FENDER WASHER. 8. PROVIDE FIRESTOPPING AT ALL LEVEL AN EXISTING DWELLING REQUIRING A BUILDING PERMIT Q Z - LIAZ E D OPENING .;::+; PENETRATIONS = WINDOWS G NOW REQUIRES THAT ALL SLEEPING ROOMS IN THE � W •t��w q. PROVIDE FLASHING AT ALL ROOF BREAKS, HOUSE BE UPGRADED WITH HARD WIRED a�o v PROTECTION 15 REQUIRED FOR AkLL GLAZED AREAS. CHIMNEYS, SKYLIGHTS, EXTERIOR DOORS, WINDOWS INTERGONNEGTED SMOKE ALARMS. W • N 0 w IN ACCORDANCE WITH LARGE MISSILE TEST OF A5TM E IQ96 AND OF ASTM 1556;. AND DECKS ETC.. 23. THE NYS GORES ALSO APPLY TO ACCESSORY Q F' • �" CONTRACTOR MAY USE WOOD 57 RUCTURAL PANELS IN LIEU OF THE ABOVE MENTIONEDWINDOW5. HOLD DOWN + SHEAR CONNECTION 10. DO NOT SCALE DRAWINGS. STRUCTURE DESIGN. v M PANELS TO BE PRECUT TO FIT OVER WINDOW NITH TO CRITICAL LOAD PATH N • HARDWARE PROVIDED. FA5TENEIR5 TO BE DE II. ARCHITECT NOR ENGINEER IS NOT RESPONSIBLE 24. GARAGE DOORS TO BE RATED FOR 120 MPH. WIND LOAD ALIGN WITH WINDOW JACK P05T5� , HEADER + SILL PLATE. SHALL COMPLY W/N1'55G CHAPTER #2504.cf.6 FOR THE INSPECTION OR SUPERVISION OF PANELS TO BE MAINTAINED ON SIITE. THIS CONSTRUCTION PROJECT. FEDERAL, STATE LABEL LOCATIONS ON EACH PANIEL. AND LOCAL ZONING AND BUILDING GODS GOMPL I ANGE SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. - ass Q ST . NAILING SCHEDULE FRAMING NOTES z TAKEN FROM 2001 EDITION WOOD FRAME CONSTRUCTION MA UAL, AMERICAN FOREST I. ALL FRAMING LUMBER SHALL BE GRADE STAMPED 10. PLYWOOD SHEATHING TO BE NAILED WITH 5 d c9 4" 4 PAPER A550CIATION DOUGLAS FIR-LARCH STRUCTURAL GRADE No. 2 OR o.c. EXTERIOR EDGES AND 6 d 12" o.c. o BETTER. I NTERMED I ATE. - SIZED FOR COMMON NAILS; CONTACT ARCHITECT FOR BOX MAIL SIZES PROJECT o: - h - 2. ALL SHEATHING TO BE APA RATED, EXPOSURE I, 5/8II II. ALL INTERIOR AND EXTERIOR FINISHES, FLASHING 0507 RAFTER/TOP PLATE 3 5d (TOE NAILED) MIN. THICKNESS OR AS NOTED. AND WATERPROOFING SHALL BE BY ARCHITECT. o Flo o CEILING JOI5T/TOP PLATE 3-5d (TOE NAILED) 3. ALL 5UBFLOORING TO BE APA RATED 5TURD-I-FLOOR, CEILING J0I5T/PARALLEL RAFTER 1-16d (FACE NAILED)) EXPOSURE I, 5/4" MIN. THICKNESS. ALL EDGES OF 12. ALL ROOF RAFTERS SHALL BE ATTACHED TO THE PLATE UT ich cl CEILING JOIST LAPS OVER PARTITION 1-16d (FACE NAILED,),' PLYWOOD TO BE SET ON SOLID BLOCKING. GLUE AND AND STUD WITH GALVANIZED HURRICANE TYPE NAIL PLYWOOD 5UBFLOOR TO FLOOR JOISTS. CONNECTORS BY "TECO" OR APPROVED EQUAL. FOR CHECKED BY: COLLAR TIE/RAFTER 2-Sd (ea. end I-I/4" : trap) NS _GABLE ROOFS BLOCKING/RAFTER 2-Sd (TOE NAILED) TIMBER PILE FOUNDATIONS, PROVIDE HURRICANE o to RIM BOARD/RAFTER 2-Ibd (END NAILED) 4. ALL HEADERS 6'-0" AND OVER SHALL BE SUPPORTED CLIPS AT ALL PERIMETER JOIST TO GIRDERDATE: TOP PLATE/TOP PLATE 2-16d (FACE NAILEL'1 WITH DOUBLE UPRIGHTS, 9'-O" AND OVER WITH CONNECTIONS. 2 / 27 / 06 TRIPLE UPRIGHTS. ALL HEADERS SHALL BE A o TOP PLATE AT INTERSECTIONS 4-Ibd (PAGED NAILS: ) MINIMUM OF 2-2X8 OR AS SHOWN ON DRAWING. 13. ALL PRE-ENGINEERED LUMBER SHALL BE GEORGIA STUD/STUD 2-Ibd (FACE NAILED)) h HEADER/HEADER Ibd (PAGE NAILED) 5. SOLID BLOCKING SHALL BE PROVIDED FOR ALL JOISTS PACIFIC GPI SERIES WOOD-I-BEAMS AND LVL TOP or BOTTOM PLATE/STUD 2-I6d (END NAILED) AND FLOOR BEAMS AS PER N.Y.5. CODE OR AS NOTED PRODUCTS OR EQUAL. ALL JOISTS, GIRDERS AND SHEET TITLE: 0 0 ® 5'-0" O.G. MIN. PROVIDE 2 SPACE FOR AIR HEADERS SHALL HAVE BEARING STIFFENERS INSTALLED IO < O (45 BOTTOM PLATE/FLOOR JOIST 2-16d (FACE NAILED,> CIRCULATION IN ROOFS. JOIST/SILL, TOP PLATE or GIRDER 4-5d (TOE NAILED) AS PER MANUFACTURERS RECOMMENDATIONS. WEB o BRIDGING/JOIST 2-5d (TOE NAILED) 6. DOUBLE FRAMING AROUND ALL OPENINGS ( skylights, STIFFENERS SHALL BE REQUIRED AT ALL LOAF AND STRUCTURAL h BLOCKIN(5/JOIST 2-5d (TOE NAILED) stairs etc. ) OR AS NOTED ON DRAWINGS. BEARING POINTS AT A MINIMUM. A SINGLE 1 3/4" GABLE ROOFS BLOCKING/SILL orTOP PLATE 3-16d (TOE NAILED) 1. DOUBLE UP FRAMING UNDER ALL POSTS AND PARALLEL LVL RIM JOIST SHALL BE REQUIRED AT FLOOR NOTES &lo° o <,30 0 lo° o �45° LEDGER STRIP/BEAM 3-I6d (PAGE NAILED, PERIMETERS. HANDLING PARTITIONS OR AS NOTED ON DRAWINGS. C STORAGE AND ERECTION OF BE AS PER MANUFACTURERS DETAILS JOIST ON LEDGER/BEAM 3-8d (TOE NAILED) COMPONENTS SHALL PROVIDE 8d COMMON NAILS ® 4' O.C. BAND JOIST/JOIST 3-16d (END NAILED) 5. ALL FLUSH WOOD CONNECTIONS SHALL BE FASTENED RECOMMENDATIONS. AT HIGH PRESSURE ZONE - 6" O.C. BAND JOIST/SILL or TOP PLATE 2-16d (TOE NAILED) WITH RATED GALVANIZED METAL CONNECTORS BY HIP ROOFS AT INTERIOR PORTIONS OF ROOF - TYP. 14. ALL MULTIPLE LVL PRODUCTS TO HAVE 2 ROWS OF 1/2" PIA. o o �30 ° PLYWOOD ROOF DECKING 8d ®4" O.G. EDGES, all O.C. FIELD "TECO" OR APPROVED EQUAL. SHEET NO: lo STRIP 5HEATHING 8d (ONE/RAFTER) GALVANIZED MACHINE BOLTS ® 12 O.G.. PROVIDE 8d NAILS a 4" O.G. AT PERIMETER INTERIOR PLYWOOD WALL SHEATHING 8d ®4�" O.G. ED6E5, 4 5" O.G. FIELD q. NAILING SCHEDULE SHALL BE AS PER THE N.Y.S. 15. T PORTIONS OF PANELS IN HIGH PRESSURE ZONES. PLYWOOD 5UBFLOOR DECKING ad ®6 O.G. EDGES, c 12 O.G. FIELD BUILDING CODE AS A MINIMUM. ALL 2X6 5TU125 r_ DRAWING IS AN INSTRUMENT PREPARED TO NOTE ., a = 4 FT. IN ALL GASES SHALL RECEIVE 5-IOD NAILS AT SILL AND PLATE. FAACILITATE CONSTRUCTION AND SHALL NOT BE COMPONENT AND CLADDING PRESSURE ZONES ALL EXTERIOR NAILS SHALL BE GALVANIZED. CONSTRUED AS A CONTRACT BETWEEN BUILDER AND OWNER. FINAL DRAWING