Loading...
HomeMy WebLinkAbout32538-Z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-33038 Date: 05/21/08 THIS CERTIFIES that the building ACCESSORY Location of Property: 8110 NORTH BAYVIEW RD SOUTHOLD (HOUSE NO.) (STREET) (HAMLET) County Tax Map No. 473889 Section 79 Block 7 Lot 53 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated NOVEMBER 27, 2006 pursuant to which Building Permit No. 32538-Z dated DECEMBER 1, 2006 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ACCESSORY GARAGE AS APPLIED FOR. The certificate is issued to DAVID & LAUREN KOLLEN (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A- ET CTRICAL CERTIFICATE NO. 3029093 11/02/07 PLUMBERS CERTIFICATION DATED N/A r � uthoiAzed ignature Rev. 1/81 f'; ' Form No, 6 N0U,26 2007 TOWN OF SOUTHOLD BUILDING DEPARTMENT is�o c 0- —� TOWN HALL T Wig OF S^L'TFIO.LD 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form), 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B� For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$25.00, Additions to dwelling$25.00, Alterations to dwelling$25.00, Swimming pool $25.00, Accessory building$25,00, Additions to accessory building $25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy- $.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commmercial $15.00 / Date. 'Wov Ylb ) , Qoc)-�' New Construction: V Old or Pre-existing Building: (check one) Location of Property: v} 52)C.4 00 House No. et Hamlet Owner or Owners of Property: U 1 N (X V-,P n14217) Suffolk County Tax Map No 1000, Section Block '? Lot 053 Subdivision Filed Map. Lot: Permit No. _ Date of Permit. Applicant: vLn Health Dept. Approval: Underwriters Approval: t� Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ �5 a QQ 3 03� Applicant Signature - 3 a MIREPR Mn��RPLIER El 5 BY THIS CERTIFICATE OF COMPLIANCE THE 5 S NEW YORK BOARD OF FIRE UNDERWRITERS 5 5 5 5 BUREAU OF ELECTRICITY 5 5 40 FULTON STREET - NEW YORK, NY 10038 SCERTIFIES THAT 5 5 5 5 Upon the application of upon premises owned by 5 55 S5 PLATINUM ELECTRIC 1 320 KENNEY S RD 8 A 0 1 N BAAYV EW RD 5 SOUTHOLD, NY 11971, SOUTHOLD, NY 11971 5 5 C5 5 Located at 8110 N BAYVIEW RD SOUTHOLD, NY 11971 5 5 5Application Number: 3029093 Certificate Number: 3029093 c5 5 Section: Block: Lot: Building Permit: BDC: ns11 5 5 Described as a occupancy, wherein the premises electrical system consisting of Cj 5 electrical devices and wiring, described below, located in/on the premises at: S 5 Attached Garage,Detached Garage,Outside, 5 5 5 5 A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed 5 5 herein, was conducted in accordance with the requirements of the applicable code and/or standard Spromulgated by the State of New York, Department of State Code Enforcement and Administration, or other 5 authority having jurisdiction, and found to be in compliance therewith on the 2nd Day of November,2007. 5 Name ( TY Rate Rating Circuit Tyne 5 Miscellaneous Cj 5 new service +detached garage S SPanels 5 1 100 2 5 Wiring and Devices 5 Fixture 1 0 Incandescent S 5 Outlet 6 0 General Purpose 5 �5] Receptacle 4 0 General Purpose 5 Switch 1 0 General Purpose 5 5 Receptacle 1 0 GFCI 5 SService S 5 I Phase 3 W Service Rating 200 Amperes 5 5 Service Disconnect: 1 200 cb 5 5 Meters: I 5 5 5 S seal 5 5 5 1 of I 5 5 5 5 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. 5 5 5 o ��������������������������������������������������������������� El Allied Design Archite kraal'. & 'ngirieeri 1 Fs t r May'5, 2008.`, 6 Town of Southold Building Dept: , ' �� _ Southold;NY 301W x 14'H x 45.'L Utility'Building •MBI.Job'# 128=0788 Building Permit#�2538 , Dear Sirs Please.be advised.that'I am receipt of verification.from lVlo . on Building.'s Construction Superintendent,tlat the referenced job has been constructed insubstantial complianceto my design dated`.08-23=06"without knowndefect'or deviation..., This.building was designed'fora a,29PSF roof snow.load and a,'120MP11 wind ; speed considering exposure category C. The construction..ve'rification specifically'states that the wind load structural. : ,provisions including fasteners;hurricane'strapping,'RT4.clips and shear walls were -installed per:plans. - Also the Verification confirms that the footings and concrete were -constructed to plan specifications. If you have.further questions,concerning this:matter,:please advi'se:'. . . : ; Yours truly,. Allied:Design A.&. E Group, PC " ,•`��Of JE011 Ronald 100 S. Pershin hb President PO.BOX 1,10 mt�tr��t°• Morton,IL 61550. .309.263.4105 __ _ ' , Alec Rini Airchiteu�ral &�`Engirieering"Gau , P C. :: z 7 , a te , f May 7, 2007 ' -Town,of Southold-Building Dept Southold;NY, RE Ro bert&,Nancie.At son 01eq :30W x 14-'H:x 45'L Garage -Southold;NY MBI�# T28=0788: Dear,.Sirs: Prase find enclosed truss design fort the truss that was used for this. ob I am also,w;riting to confirmand advse,;that the;foo'tings and:foundation were obkir ed 4 have been installed in,accordai c�;t: rriY Mans rJ.?ted 01=17.07. , l ) Footings were placed'.4'10"'.'.belo,u`grade and Were,drilled tli Nli diam0t6rll§pecified on'the plans 11%4"`xJ1/4":x 147'Ga eolunin stilts were attached to,each column corner with(3),0 14$" dia X�' stainless mills. 3 ) Concrete;for each footing was placed in accordance with the plans Yours-trulY; Alhd Design A&,E Group,PAC l o Ronald L•..Sutton� �� �' � ,►►�y, President •a c 140Serslung . ros®X110 04 `�MOr �IL G1550 'Meuara� i 309'213 4105 ' FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 32538 Z Date DECEMBER 1, 2006 Permission is hereby granted to: KOLLEN 8110 NORTH BAYVIEW ROAD SOUTHOLD,NY 11971 for CONSTRUCTION OF AN ACCESSORY GARAGE IN THE REQUIRED REAR YARD AS APPLIED FOR at premises located at 8110 NORTH BAYVIEW RD SOUTHOLD County Tax Map No. 473889 Section 079 Block 0007 Lot No. 053 pursuant to application dated NOVEMBER 27, 2006 and approved by the Building Inspector to expire on JUNE 1 _-2-0.0- Fee $ 330 . 00 Authori ed Si nature ORIGINAL Rev. 5/8/02 J �pF S0(/l�, h�� Olo courm,� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] 1 LATION [ ] FRAMING / STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: �I Ot , DATE f INSPECTOR— Li p � �OF SOUly �o� oho TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION lk<FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION 1 / REMARKS: � �r � �^ ffjy J f J f; DATE . - INSPECTOR 9 Flitl)INSPECTION REPORT DATE I COMMENTS FOUNDATION(1ST) ------------------------------------- FOUNDATION (2ND) L(n) t4 ROUGH FRAMING& r PLUMBING 2 '� INSULATION PER N.Y. STATE ENERGY CODE a FINAL ADDITIONAL COMMENTS C7 no �- Z m 1 Ci y O z y� r x C trJ b y OFFICE.' CUTCHOGUE, N.Y. JOB NO. 128-0788 z � R � 6. 06. r z O Z SL 15-8-2 SL 15-8-2 ''finn z HO 1-3-8 HO 1-3-8 �/ v SL 7-1 1-2 7-9-0 7-9-0 7-1 1-2 LU 0 Q EP 7-6-4 14-10-8 22-2-12 29-9-0 z TC 7-6-4 7-4-4 7-4-4 7-6-4 co LLJ c Q N z 4 W I I C� 3x5 3x5 B D v Tl T2 Q 6-3-0 W2 Z 12H W3 18G-RL8H-1Ox14 W4 W5 18G-RL8H-1Oxl4 U �� A E L1J W 1 z 1— 2 LGl LG2 = 0� U a� o Bl — 0.05202 B2 I H G — K i F Q #5x7 — 418G-RL8H-7xl2= #5x7 LL V> m BC 1 6-9-1 b-3-13 11 b-3-13 6-9-1 ucoi Lu p EP vv o 8-4-15 14-8-12 080 21-4-1 28-1-2 ' r M SL o0 0 6-9-1 6-3-13 6-3-13 6-9-1 200 z __ -cam 0 1 I x J d J H 29-9-0 Q 8 30' S.C. 2090 TRUSS DRAwNeY: B. HAYES SCALE: I/e"=1'-0" 0A0 DATE: 5-7-07 CIF CHECKED B Y. r�`Q^ DATE. • `� 1 REVISED DATE.' � • • SCALE.' • • SHEET NO. ,�.� 1 OF 2 e OFFICE.• r' CUTCHOGUE, N.Y. JOB NO. 128-0788 TRUSS DESIGN LOAD=288 PLF REQUIRED TRUSS LOAD= 33 PSF AT 7-6' O.C.=247.5 PLF LIVE LOAD 29 PSF Z CLf DEAD LOAD 4 PSF 0 } CEILING LOAD - PSF V Z O i TOTAL LOAD 33 PSF o J w 0 z 30' S.C. 2090 TRUSS Q o z Robbins Engineer in Inc/Online Pl..- APPROX. TRUSS LIEIGHT: 271-3 LBS 0213001 -------------Webs------------- Trusses Manufactured by: �l w B -J 0.18 1290 C Morton Buildings, Inc. Online us -- Version 19.0.018 J -C 0.25 1615 T Analysis Conforms To: AUti DA 11-MAY-06 C -C 0.25 426 T n verticSI/TPIal 95 b 02 / C -G 0.25 1616 T Run vertical thru bottom chord V CSI -Size- ----Lumber---- G -D 0.18 1290 C Joint H Q TC 0.95 2x 8 SP-2401 -----------Sliders------------ Prevent truss rotation at all BC 0.89 2x 6 SP-2401 A -K 0.05 1351 C bearintt locations. Z � EB 0.25 2x 4 SP-#1 F -E 0.05 1351 C Truss is designed for no SL 0.05 2x10 SF-#1 ceiling load. /F- TL Defl -0.48 in J -H L/715 NOTE: USER MODIFIED PLATES V Brace truss as follows: LL Defl -0.39" in J -H L/881 This design may have plates Z !Z= 0 O.C. From To Shear // Grain in K -B 0.70 selected through a plate = TC 2- 8- 0 0- 0- 0 29- 9- 0 monitor. BC 7- 6- 0 0- 0- 0 29- 9- 0 Plates for each ply each face. Max comp. force 7693 Lbs o PLATING CONFORMS TO TPI. Quality Control Factor 1.00 Loading Live Dead (psf) PLATE VALUES MAY BE VERIFIED Q TC 26.0 4.0 WITH ROBBINS ENGINEERING. z BC 0.0 2:1 GRIP VALUES BASED ON SP Total 26.0 60 32.0 USING GROSS AREA TEST. V x Spacing 108.0" Plate - LOCK 20 Ga, Gross Area w Cr) m Lumber Duration Factor 1.15 Plate - RHS 20 Ga, Gross Area Q 0 Plate Duration Factor 1:15 Plate - RLBH 20 Ga, Gross Area 00 TC Fb-1.00 Fc=1.00 Ft=1.00 Jt Type Plt Size X Y JSI c BC Fb=1.00 Fc=1.00 Ft=1.00 A RL8H 10.Ox14.011.0 1.7 0.91 O L i B LOCK 3.Ox 5.0 Ctr Ctr 0.43 w Jt React Uplft Size Req'd C#LOCK 7.Ox 9.0 Ctr-0.5 0.93 Lbs Lbs In-Sx In-Sx D LOCK 3.Ox 5.0 Ctr Ctr 0.43 Q g A 4284 0 5- 8 3- 9 E 17L8H 10.Ox14.0-7.7 2.0 0.94 - E 4284 0 5- 8 3- 9 K LOCK 5.Ox 7.0-0.5 Ctr 0.86 J#LOCK 5.Ox 7.0 Ctr Ctr 0.77 Membr CSI P Lbs Axl-CSI-Bled H#RLBH 7.Ox12.0 Ctr 0.8 0.78 Top Chords---------- G#LOCK 5.Ox 7.0 Ctr Ctr 0.64 DRA wN B Y.' B. H AY ES A -B 0.95 7693 C 0.13 0.82 F LOCK 5.Ox 7.0 0.5 Ctr 0.86 B -C 0.15 7171 C 0.11 0.64 DATE.' 5-7-07 C -D 0.15 7171 C 0.11 0.64 # = Plate Monitor used _! D -E 0.95 7693 C 0.13 0.82 `G`y ` L CHECKED BY., B EFER-------- ottom Chords--------- R TO RMM12FS EUG. GDNERAL K -J 0.89 7182 T 0.39 0.50 NOTES MID SYMBOLS SHEET FOR �` ••j• �;( DATE: J -H 0.59 5566 T 0.30 0.29 ADDITIONAL SPECIFICATIONS. H -G 0.59 5566 T 0.30 0.29 • TO•• REVISED DATE: G -F 0.89 7182 T 0.39 9.50 NOTES: Q BCtbllt E1911e elll(J,It0A110e Plls^'O I'96v^fIIi VPfcUI 19.OB16 EItJ�Pl10g-VOOYd[S27 fS1�T:l ISIAY P aj 1012 , .0 + • E: \ ` •d' . . `. SHEET N . •'�. S CALE: : ' v - ,. ,]zz:)J U - ��� TOWN OF SOUTHOLD PROPERTY RECORD CARD 7-L f - OWNER STREET VILLAGE DIST. - - SUB. LOTa� - FORMER OyVNER"JQ a h. ,r,' N E ACR. ' S W TYPE OF BUILDING RES. SEAS. VL. FARM COMM. CB. MILS. Mkt. Value LAND IMP. TOTAL DATE REMARKS s L 7Lc, p 136 :7 - 1 Z7Z 0-9 / �/ z/ !-, / r `7 5 f W _ Ila. Sid v o //,-t) r� nay 1 v oot 1r, 7 ~i `ry 00 l� CTZ) g� 1 z billable FRONTAGE ON WATER Noodland FRONTAGE ON ROAD AeodowkNid DEPTH iouse Pli# BULKHEAD Total s , ,:t r F COLOR NAT . TRIM - - - I — - I I � 11►� . Ex' 1:s A " I � ``C� 3:s 19 3 vl—I— _�l1 Extension. Z „Ex S si " � -r 1 1C�K`2C� Foundation Bath i I 31/ Dinette X\ ---- - 1�- -E "--� - --Basement - K sement �uL_ (FloorsK. --= Porch 1�-.'<L S 30� �/�Q--T w-- I ---- - ----- — Ej�z1 I Ext. Walls —lam r��lnterior Finish Breezeway i Fire Place ' I ( Heat I� I DR-- R arage Z, �S 7 Type Roof 1�P i fig. YP (Rooms 1st Floor BR. Patio (Recreation Room I 1Rooms 2nd Floor I .- I FIN. B ' O. B. (Dormer I I Driveway----------------- Total i I ' 7 3 9� NORTH B AYVIEW ROAD rIE= I7s.00' S 72°59'30"E 100.00' R=25.00' / CONC MON A=39.27' / LI W z FENCE CHAIN LINK FE p \i o o ..J O O O Ld O � 21.8' 22.3' WOOD ENTRY GARAGES STEPS SURVEY OF N W RAILINGS LOT 15.1' "0 00 ---18.s' IN MAP OF LEEWARD ACRES WOOD FRAME RESIDENCE AT BAYVIEW 24.7 14.4' SITUATE 21.6', 21'9' SOUTHOLD 7.4' TOWN OF SOUTHOLD WOOD DE W RAILINGS , SUFFOLK COUNTY, N.Y. WOOD STEPS 6.0' SURVEYED FOR: DAVID KOLLEN LOT 3 LOT 1 LAUREN KOLLEN . W U . Z FM# 5599 w DATE FILED JUNE 4, 1971 o � X o TM# 1000-079-07-053 U) CONC MON GUARANTEED TO: DAVID KOLLEN LAUREN KOLLEN COMMONWEALTH.LAND TITLE INS. CO. 10 7' 30.3' WILMINGTON FINANCE, INC. METAL N BUILDING 11.2 2 9 NiF 4 LOT 4 3. W � T \� . ;JTH. LD N 0 0 O O z SURVEYED: 19 JULY 2006 CONC MON SCALE 1"= 40' N 72°59 30 W 100.00 AREA = 40,000 S.F. OR LOT 43 0.918 ACRES GUARANTEES INDICATED HERE ON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY, SURVEYED BY IS PREPARED,77TLE C N BEHALFD ON HIS OMPANY,, GOVERNMENIALAGENC�£ STANLEY J. ISAKSEN, JR. LENDING 1NS77TU710N, 1F LISTED,HEREON, AND .P.O. BOX 294 TO THE ASSIGNEES OF THE LENDING INSTITUTION. GUARANTEES ARE NOT TRANSFERABLE TO NEW S FFO L K. N.Y. 1 1 5 6 ADD17IONAL INS77TU77ONS OR SUBSEQUENT OWNERS. 631 -7 4-5835 UNAUTHORIZED ALTERATION OR ADD177ON TO THIS SURVEY IS A VIOLATION OF SECTION 7209 OF 7HE NEW YORK STATE EDUCATION LAW. COPIES OF THIS SURVEY MAP NOT BEARING I CE SE LA D VEYOR THE LAND SURVEYORS EMBOSSED SEAL SHALL NOT BE CONSIDERED,TO BE A VALID TRUE Li N0. 49273 06R 151 1 COPY. 1. 27 MAR 07 ADD METAL BUILDING. . TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health W fit' SOUTHOLD,NY 11971 3 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 7Survey www. northfork.net/Southold/ PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees NA Examined ,20 Contact: Approved 120 Mail to: P,(�, ICJ Disapproved a/c 46T p 7M(I D Phone: (.51- 7aJ�' Expiration ,20 Build' g Inspector \01 L st APPLICATION FOR BUILDING PERMIT =� Date �� , 20C>- INSTRUCTIONS a. This applicationMUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans, accurate plot plan to scale. Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months.Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. e (Sig 0eaplAican o*nae,if a corporation) `� �• l ��c.�c�-tom �I (Mailing address of applicant) State whether applicant is owner, les ee, agent,; gent, a 6h. ect, engineer, general contractor, electrician,plumber or builder A�,�D� Name of owner of premises , LAUMJ (As on the tax roll or latest deed) If applicant is a c�rppration, signature of duly authorized officer (Name and tittle of corporate officer) Builders License No. �j ^ Plumbers License No. Electricians License No. Other Trade's License No. 1. Location Lion of land onA �i proposed work will be done: ) N i 1��4 VZEU ED House Number Street Hamlet County Tax Map No. 1000 Section 7G( Block-7 Lot S Subdivision Filed Map No. �jS�jG( Lot (Name) 2. State existing use and occupancy of premises and intended use and occu ancy of proposed construction: a. Existing use and occupancy T t� X tom( b. Intended use and occupancy 6 Lk FAVAX-L-LA lLL!rbl�G 3. Nature of work(check which applicable): New Building Addition Alteration Repair Removal—Demolition—Other Work (Description) 4. Estimated Cos Z6,DDD Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars C{ 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. �L - 7. Dimensions of exi res,_if any.: Front Rear Height Num er Dimensions of same struc alterations or additio ns: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front 5P ` Rear 3 ` Depth Ll Height 7V 0 P&&,V- Number of Stories 1, 9. Size of lot: Front /00 F Rear /M c Depthlaia ate of Purchase�-�� 'd� Name of Former Owner 1 . zone or use district in which premises are situated F 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO-)4 13. Will lot be re-graded? YES NOX—Will excess fill be removed from premises? YES NO 14.Names of Owner of premises Addressf L� RCX—Z> Phone No.651- 746S-1612 Name of Architect Addresses CGL-CKVE. Phone No 4�-7Zq Name of Contractor Address4&t!QD�jj 7V Phone No. &N-TV-Wg& 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) S : COUNTY O being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)He is the A44i (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this day-of vc m 20 r 4,X11 Notary Public rr/ Vgnr 'of t o -�� ry rr � i aA M1r �*�:,`FI�4 EC�It �EiBIM a�TOO�baY '�1(1C�0�7�H���t �` �: r ':�� e 21 � �� x '� '' �`s*• � �„1e 'a �,e �5 79. 7 53dTtuth�ldy % •«n= ,.. t ::�,at a,� w•-a sus a � ,. :.a` t., `��'r '�`\ sfa., a\m\ : 1n �a �-, s � �-m�• s"a,� a \•ems' �:�k �� \� \ � a a a x � a cam 3 �. 'aY \� �w a�\;�. A e7�" v��'`fie ': ac�\�.* a •m'�""�x .". 'rm \ •. � r{! �a+� Y aaa '.. sc .s '\ '°,` �`:LS sn xm�• =r .� gip. u�.�?�.g.�s x� x�\ � ks a� '\ Ym.�ca\tea r$�' •aas .��m �, 4 \�,� m Z\\� �`: a=F,". �r'av'�' �z•,',n �, �, p � 'f s� �� L�V,�.. �:.jj �'•$�hw'dr raI'� Vic. amp'�8�4f C+1��� 3:: ��a'\c..a�• .:�a � ������ �.. Rgpl Spallf s�a1� s< a A: � .. m_ Rxn 2 a,s\ s'. > xi s.;.a� �.o EE •' ;\�<, A �`' I� ,\ , a�? P1'CiClpli7 j� aY \ s a'm`°'.. r.. ;� �. -n,• ,., 'i1B \`b,g 's"9 •� -.".;:w:+ .... a " \��aO a um a�...,, °� �° "laa`'+��a .\\.';. a S H< i f : Ms. , •� � � ��� �i_. >4E MO. y\ .. s�•m, 'vf m*`��mI �w�`itCr : Y " \W a `mob ':F�� ",g. w•' ,. a w � pp '' �m+ kx ,+,� s•, \ a��m� � ' t � IItlBit- •':> ,_ ,�, it-N- ��es m s 3`,` 'A`a: '�\• e \� _ �� ak..... ` � wIC�C ,�r \ NORwo a m��s�� ���� '�� va�� ��1f�T,}t s ,.r• ,�a.� r,�� �~r ':: WHAIII, F°q,�s. �3 �"9 Y'� zi'arR''K {� 351�1� v a ?F \� .sa c°a•'' \`l•h.d. m � �x ws C F'dadj p6 .em:". �'`� i Y a a aw' ._'.�*, ��' ti`a h .".. �� x ,r<. \ '. t \.c*. ;`` N< 3 F � `" v ��' '~\ .° ",y\I<, �vmrEg � '� � _' t � a i y°ah,..ws ..;; Y '� \ w \ a pu y••- � *:a xa\ � o\ �� .s � =a r F ,, WON �m o� �a \ to rc+k�� �, ��• m ; �4 � m�,�� =�l�C��p ���If� � � "�mma�w�� ���� `�� ,� H`1d _ PN Ec: �\£\ �mcp - •�w� k, a w .` r .:i. c \ XTI MIN III SAIIx g k1 4m "' kw _:E b+�� '. a2 8 s. �°•.s m� T�w\� `�Va ra:z�° ?' .w.•lilt a:. •.g�a E.'�xz�: ,aa.22 MCA x �\ '2" v•\ .a -_ a° a �\ a a�L m` i '� s y \ ark a m s �e gw\. � w s caa Yy\� r�. s m�e ,y g @ 3 F l,;T \ ��\1 S •�a D�` � �� ym 4.�<�\ S•.:'.�\D - \ mix Fit im w�\m�..my \ c 3s y `c \�. �� ;�; `.: rk °"��,.x.• a a , ,..`..mw\y }b a •':ssa. + `� � �.F as �.�' #�.�\t -.-� i hsw s' a �rc'�,w c' � � m$-. `' ;,���� � �m �k � `a�' a �.s �� �' �\ "�< °' � m "�.:�. ��\�. 3 �°� ?m�.�\m���m\ �'_.�rm� x '\� ���•"4 "e+a�y\�mti.�.. z a a\3a ..� � y�aa r as a 'ate'�` >p:;; e° � a1\\�.F�� a -.a: `a Yes ... �s. ��\ mgx,a :.. -•s' 44 `" \ ffift a oas.'"az<sir s<m * mc� m Y �� F� <�ax✓ �° a o�m I'll w r i;,.M� � \x� �Y\„ �x�mx"a\m ��cs �se\ue,�b,•a�`3x�: a\fiex....'��k s< �2+ ��- \ �a\'"•':�v>eR$•\^a G a\�1�;:m«ex x\�x c��nxs�n,"m :Ii _ r �`• 2 r o \ r w Aa ""'""� sm w. S• �� ° m.. \ aw°n•? \� \�.:'.r a� a\ x .§ mf74, x �'s��w � r� .'s} \ a.°� a \ •..�° a.' \> \�F >��" r s" \ •§P a,a tip' *m�ia a`\ � gm2 a„.„� .* •m - ..`� t2a `. ... `�'" ,mas e�m,m mx "w w�., ,� gme d\ +m'aa m IwW z�' � •at�m�a••.,� m � .Y� as a a �...�. x � � .,�. 1 ad":,x ���,a�, Or •� : �'* _a ,..:. '�st Vim •i a ., aa r�• \��\ s § a °'3pm a�y'� � '.`AM a'.` 'ack'�'. t .wa. ,*\•s• •, �.R\S� u micas. S 72 59'30"E 100.00' cola:xw-�vLLJ 3- — v HAiA i;U r'EWE } I I :`tWO ENTRY l:E 5 STE PS 5`tPV } ijF LOT 2 91 IN I _ MAP OF LEEWARD ACRES AT BAYVIEW SITUATE s SOUTHOL® '�4��, -- ..__.. �.>-:- •-4'.`—_ .:�_ f TOWN OF SOUTH( s SUFFOLK COUNTY, N.Y. SURVEYED FOR: DAVID KOLLEN LDo 3 LOT I LAUREN KOLLE'1. t.: z FMn 5599 DA TI ci . Tr:�7 UUAF,ANTFED TO: DAVID KOUEt; EAU'EN I«L!EN N � COMMONWEALTH LAND TITI-E INS. CO f f � � f 1 1 t i 1 1 1 I 1 E 1 t 7 � Ta ro 1 l C) o , 1 Q GRASS MAlNT tNED THIS AREA 11 :U'R VE'r EV: 19 JUC Y' 2006 i "' •-' Cave rtor: N 72'59 3 ----- 100.00ARE,E _ an,Ot�il S.F. ClR LOT 43 0.9 18 ACRES OFFICE: CUTCHOGUE, N.Y. MORTON BUILDINGS GENERAL SPECIFICATIONS JOB NO. 128-0788 LAMINATED COLUMNS - NO. 1 OR BETTER SOUTHERN YELLOW PINE NAIL LAMINATED 3 MEMBER S43 COLUMNS USED IN MORTON BUILDINGS ARE PRESSURE TREATED BELOW GRADE TO A RETENTION OF .8 POUNDS PER CUBIC FOOT WITH CHROMATED COPPER ARSENATE TYPE III, OXIDE IN CONFORMANCE WITH USEPA GUIDELINES AND AWPA STANDARD C28. THE TREATED PORTION OF THE COLUMN o U EMBEDDED IN GROUND SHALL BE LAMINATED WITH STAINLESS STEEL NAILS. , u 10 ll- 1V FOOTINGS AND ANCHORAGE - COLUMN HOLES ARE DUG A MINIMUM DEPTH OF 4'-8" BELOW GRADE o (SEE PLANS FOR DIAMETER AND DEPTH). COLUMNS WITH GALVANIZED SUPPORT STILTS ARE PLACED IN Q_ THE HOLE. CONCRETE (MINIMUM COMPRESSIVE STRENGTH 2500 PSI) IS POURED IN PLACE TO THE SPECIFIED THICKNESS (SEE PLANS FOR REQUIRED THICKNESS ABOVE AND BELOW THE COLUMN). -THE Q z COLUMN IS THEN BACKFILLED WITH SOIL AND COMPACTED AT 8" INTERVALS OR BACKFILLED WITH CL Z CONCRETE (SEE PLANS). 0 'TREATED LUMBER - PRESSURE PRESERVATIVE TREATED LUMBER OTHER THAN LAMINATED COLUMNS ARE AL LJ NO. 1 OR BETTER SOUTHERN YELLOW PINE AND CENTER MATCHED OR NOTCHED AND GROOVED, C) PRESSURE TREATED TO A NET RETENTION OF .4 POUNDS PER CUBIC FOOT WITH A CODE AND INDUSTRY 1171-110 APPROVED PRESERVATIVE TREATMENT IN ACCORDANCE WITH AWPA USE CATEGORY UC4A. ^ , LW FRAMING LUMBER -SIDING NAILERS ARE 2x4 S4S OR 2x6 SPF NO. 2 OR BETTER SPACED APPROXIMATELY XNXI 36" O.C. WITH ALL JOINTS STAGGERED AT ATTACHMENT TO COLUMNS. ROOF PURLINS ARE 2x4 S4S NO. ca ---..al 2 OR BETTER ON EDGE SPACED APPROXIMATELY 24" O.C. ALL OTHER FRAMING LUMBER IS NO. 2 OR k BETTER. a<.. .. .3 ROOF TRUSSES - FACTORY ASSEMBLED WITH 18 OR 20 GAUGE GALVANIZED STEEL TRUSS PLATES AS z REQUIRED AND KILN DRIED LUMBER AS SPECIFIED, IN-PLANT QUALITY CONTROL INSPECTION IS �✓ :.::.:., CONDUCTED UNDER THE AUSPICES OF THE TPI INSPECTION BUREAU. TRUSSES ARE DESIGNED IN ACCORDANCE WITH CURRENT STANDARDS AND SPECIFICATIONS FOR THE STATED LOADING. \ O `o SIDING PANELS (KYNAR 500 / HYLAR 5000) - 0.019" MIN., G90 GALVANIZED OR AZ55 GALVALUME, WITH ! 1 p AN ADDITIONAL BAKED-ON KYNAR 500 / HYLAR 5000 FINISH WITH A NOMINAL 1 MIL. PAINT THICKNESS �I I I.i ON EXTERIOR. F- p ROOFING PANELS (FLUOROFLEX 2000 T"') -0.019" MIN, AZ55 GALVALUME WITH AN ADDITIONAL BAKED-ON THICKNESS POLYURETHANE PRIMER AND KYNAR 500 / HYLAR 5000 TOPCOAT WITH A TOTAL BUILDING DESIGN CRITERIA MINIMUM PAINT THICKNESS OF 2 MILS ON EXTERIOR. � � 2003 BUILDING CODE OF NEW ® BlUILDING CODE O 0 YORK SLATE ('� m TRIM - DIE-FORMED TRIM OF 0.019" MIN., G90 GALVANIZED OR AZ55 GALVALUME STEEL ON GABLES, U1 SE GROUP U °'�- O RIDGES, CORNERS, BASE WINDOWS, AND DOORS WITH SAME FINISH AS ROOFING OR SIDING PANELS. C:ONS'TRUCTION TYPE VB a I'll OOR AREA 1350 SQ FT z GUTTERS - 5" K-STYLE, .030 HIGH TENSILE ALUMINUM GUTTER, KYNAR 500 / HYLAR 5000 FINISH TO MATCH MEAN ROOF HEIGHT 18.0 FT LJLJ s TRIM, ON BOTH SIDES OF THE BUILDING. BIUILDING CATEGORY IV ® w ROOF SNOW LOAD* 29 PSF °" ADDITIONAL NOTES GROUND SNOW LOAD 45 PSF S 1.) ALL PLOT PLANS AND RELATED DETAILS SHALL BE PROVIDED BY OWNER UNLESS INCORPORATED WIND SPEED (Vss) 120 MPH I I I WIND IMPORTANCE FACTOR 0.77 _J AS PART OF THESE DRAWINGS. _J 2.) ALL INTERIOR PARTITIONS AND ROOM FINISHES IF NOT INCLUDED WITH THESE DRAWINGS SHALL BE EXPOSURE CATEGORY C PROVIDED BY OWNER, STANDARD FINISHES SHALL HAVE LESS THAN 200 FLAME SPREAD RATING AS INTERNAL PRESSURE COEFFICIENT ±0.18 REQUIRED BY ASTM E84 FOR ORDINARY CONDITIONS AND 25 OR LESS FOR EXITS, PASSAGEWAYS, BUILDING DESIGN CONDITION ENCLOSED WIND LOAD DESIGN ASCE 7 METHOD 2 AND CORRIDORS. "LONE 1 E 20.5 PSF ....� ...,��._. 3.) FLOOR COVERINGS JUDGED TO REPRESENT AN UNUSUAL HAZARD SHALL MEET THE SAME TESTING DRAWN BY. B. HAYES ZONE 2E -26.6 PSF PROCEDURES AS REQUIRED FOR WALL AND CEILING FINISHES. ZONE 3E -18.2 PSF DATE: 7/20/2006 4.) MORTON BUILDINGS GENERAL SPECIFICATIONS APPLY UNLESS INDICATED DIFFERENTLY ON ZONE 4E -17.0 PSF CHECKED 8Y: J. SMITH SPECIFIC JOB DRAWINGS OR SUPPLEMENTAL INFORMATION. ZONE 5E 16.8 PSF 5.) KYNAR 500 IS A REGISTERED TRADEMARK OF ATOFINA CHEMICAL, INC., HYLAR 5000 IS A MAIN WINDFORCE RESISTING SYSTEM DATE; 8/21/2006 (ALL FORCES ACT NORMAL TO THE SURFACE) ZONE 6E -13.0 PSF REVISED DATE.' 1/1 I/2007 B.D.H. TRADEMARK OF SOLVAY SOLEXIS. (FOR ZONES SEE MWFRS ON ELEVATIONS PAGE) ZONE 1 14.8 PSF (MAXIMUM VALUE SHOWN) ZONE 2 -18.5 PSF REVISED DATE' 2x4FK 1 1/05 ZONE 3 -13.8 PSF REVISED DATE. REVISED DA TYPICAL LUMBER SPECIFICATIONS - 2001 NDS ZONE 4 -12.7 PSF TE: SIZE DESCRIPTION BENDING VALUE Fb ZONE 5 12.4 PSF SHEET INDEX 2x4 NO. 1 & 2 SPF 1313 PSI ZONE 6 -10.0 PSF SHEET# DESCRIPTION 2x4 2100f MSR SPF 2100 PSI ZONE 1 14.5, -23.5 PSF 2x6 NO. 1 & 2 SPF 1 138 PSI COMPONENT &CLADDING WIND LOADS ZONE 2 14.5, -41.0 PSF GI OF G 1 SPECIFICATIONS & SHEET INDEX ZONE 3 14.5, -41.0 PSF I HEREBY CERTIFY THAT THE STRUCTURAL DESIGN FOR 2x6 NO. 1 SYP 1650 PSI (ALL FORCES ACT NORMAL TO THE SURFACE) Y ME THIS BUILDING WAS PREPARED B O R ! Y S 1 OF S9 COLUMN PLAN (FIOR ZONES SEE ELEVATIONS) ..�� �f 2x8 NO. 1 SYP 1500 PSI ZONE 4 25.1, -27.9 PSF DIRECT SUPERVISION AND THAT I AM_ jjfl CW kl�llzi. S2 OF S9 TRUSS PLAN, TRUSS DRAWING, & DETAILS 2x10 NO. 1 SYP 1300 PSI ZONE 5 25.1, -34.5 PSF LICENSED/REGISTERED PROFESS10 �G� E f?, Q S3 OF S9 TRUSS DETAILS & WINDBORNE DEBRIS DETAILS 2x12 NO. 1 SYP 1250 PSIS•'��,t, L S4 OF S9 ELEVATIONS ALL 1950f MSR SYP 1950 PSI * ROOF SNOW LOAD CALCULATIONS (� �` • 0, _ S5 OF S9 SECTIONS & DETAILS 1 1/2"x16" LAMINATED VENEER LUMBER 2800 PSI ' 4.�Cd •• S6 OF S9 SECTIONS 3 1/2"x15" GLU-LAM 1650 PSI Ps = 0.7 x Ce x I x Pg x Ct x Cs RONALD L. SUTT P.k.�i� S7 OF S9 SINGLE SLIDING DOOR DETAILS 5 1/4"xlb 1/2" GLU-LAM 2400 PSI Ce = SNOW EXPOSURE FACTOR = 1.0 DATE: 2-O f I = IMPORTANCE FACTOR 0.8 S8 OF S9 SHEARWALL DETAILS 5 1/4"x19 1/2" GLU-LAM 2400 PSI = Pg = GROUND SNOW LOAD = 45 PSF SCALE:AS NOTED - S9 OF S9 FASTENING SCHEDULE NOTE: HIGHER GRADE MATERIAL REQUIRED AS NOTED ON PLANS. Ct = THERMAL FACTOR = 1.2 Cs = ROOF SLOPE FACTOR = 0.94 SHEET NO. Ps = 0.7x 1.0x0.8x45x 1.2 x 0.94 = 28.43 PSF G 1 OF G OFFICE: CUTCHOGUE, N.Y. JOB NO, 128-0788 __j 1' o 10 r) 1 N 01 O a_ � W m OZ � W � Z 0 0 � w W � m Lu COLUMN PLAN LEGEND o o - 3-2x6 LAMINATED COLUMN LOCATION D 0 - 3-2x6 LAMINATED COLUMN LOCATION W/ O V 4'-0" EMBEDMENT BACKFILLED TO 4" BELOW GRADE r - HEADERED TRUSS LOCATION 12 - (1) 3068 9-LITE FIBERSTEEL WALKDOOR W/LOCKSET :z Q- (1) 14'-9"xl 4' TWIN PANEL SINGLE SLIDING END DOOR LJLJ W/ I" HEAVY DUTY THERMAX I--- OZ - (1) 15'xlN TWIN PANEL SINGLE SLIDING SIDE DOOR E"`- ►- W/ 1" HEAVY DUTY THERMAX �/ p - (4) 3065 SKYLITES (VERIFY LOCATIONS) A 7/16"OSB SHEARWALL (SEE DETAIL SHEET S8 OF S9) a N iv (Qs, l- (1) 30"x30"ATTIC ACCESS PANEL (VERIFY LOCATION) LY] 16"R - 16" DIAMETER FOOTING W/ x o 0? �- 8"THICK MINIMUM READI-MIX CONCRETE O O m o ' N N r^i BELOW BOTTOM OF LOWER COLUMN WITH 0 ADDITIONAL READI-MIX TO TOP OF 218M STILT (9"±). PLACE CONCRETE BELOW AND ABOVE BOTTOM OF n" 15'-3" 7' 1 1/2" 7' 6" 7'-b" 7'-4 1/2" LOWER COLUMN IN ONE OPERATION. 16'W - 16" DIAMETER FOOTING W/ Z_ l'-0"VENTED SIDEWALL OVERHANGS MIX (5)50# BAGS OF SACKRETE WITH 2-1/2 L I I s l.� ui C A I GALLONS OF WATER. PLACE CONCRETE BELOW w S6 S5 1'-0"NON-VENTED ENDWALL OVERHANGS AND ABOVE BOTTOM OF LOWER COLUMN IN h ONE OPERATION. USE 218M STILT. (CONCRETE o — _ MINIMUM COMPRESSIVE STRENGTH = 2500 PSI) l 1 I 0 16"W 30"B 24"B 24"B 24'B 16'W 29 9" � - 291-911 24"B -24" DIAMETER FOOTING W/ 10"THICK MINIMUM READI-MIX CONCRETE BELOW ----�U 0 N �y BOTTOM OF LOWER COLUMN WITH ADDITIONAL ---� C A s I LOWER COLUMN N ONE OPERATION READI-MIX BACKFILLED TO 4" BELOW GRADE. S6 S5 I LLACE CONCRET BELOW AND E ABOVE BOTTOM OF 22'-4 1/2" id6"R 16"R — — 22'-4 1/2" 30"B -30" DIAMETER FOOTING W/ 13"THICK MINIMUM READI-MIX CONCRETE BELOW BOTTOM OF LOWER COLUMN WITH ADDITIONAL B. HAYES s o DRAWN BY. B B READI-MIX BACKFILLED TO 4" BELOW GRADE. S5 I S5 ^ PLACE CONCRETE BELOW AND ABOVE BOTTOM DATE.' 7/20/2006 14'-1 1 1/2" 16"R OF LOWER COLUMN IN ONE OPERATION. 1 6"R r 14'-10 1/2" CFIECKED BY: J. SMITHI I — L—J ROUGH OPENING SCHEDULE DATE: 8/21/2006 REVISED DATE.• 1/1 1/2007 B.D.H. � UNIT SYMBOL D I O U I — FROM LEGEND WIDTH HEIGHT REVISED DATE., S6 S6 16"R — 7'-4 1/2" REVISED DATE. � 38 1/4" 81" REVISED DATE.' 16" r L4"B 24"B 24"B 24"B 24"B 16"W .0 Q+ + '46 7-4 1/2" 7-6" 7-6" 7-6" 7-6" 7-4 1/2" --•^" Cam✓ �� ~ It11N 17+ 0l ' O (V N CV N o CT o m o v 1 2' 8' SCALE: 1 4' 16' SCALE:AS NOTED N COLUMN PLAN SHEET NO. S 1 OF S 9 SL 15- 8- 2 SL 15- 8- 2 OFFICE,'CUTCIOGUE, N.Y. HO1- 3- 8 HO1- 3-8 - SL 7-1 1- 2 7- 9-0 7- 9- 0 7-1 1- 2 TRUSS DESIGN LOAD = 288 PLF JOB NO. EP 7- 6- 4 14-10- 8 22- 2-12 29- 9-0 -• 128-0788 REQUIRED TRUSS LOAD = 33 PSF AT 7'-6" O.C. =247.5 PLF TC 7- 6- 4 7- 4- 4 7- 4- 4 7- 6- 4 -_ #7x9 = LIVE LOAD 29 PSF el C DEAD LOAD 4 PSF CEILING LOAD - PSF o TOTAL LOAD 33 PSF v 4 �- 30 S.C. 2090 TRUSS �0 N 3x5 3x5 // Robbiv rng invert-- --------/011 ells APPROX.----- ---- MIGHT:u. 271.3 LB9 01 0213001 --Pfebx------------- h usses liana fact ured by: _ � D -J 0.13 1290 C Horton❑uildinils, Inc. Unlineryas -- Version 19.U.U18 J -C 0.25 1615'r AAaly31S Conto1 ro: Cl B D Ruff DAT.' 11-MAY-06 If -C 0:06 426 T AUSI/'rP1 75 6 02 U� T2 C -G 0.25 1616 T Run vertical thru bottw.elurd Uj CSI -Size- ----Luniwr---- G -D O,13 1290 C Jai nt If rl -Sliders---------"-- Prevent. truss rntatian at all 6- 3-0 3-O WL DC 1.U9 2x 6 SP-24U1 A -H 0.05 1151 C hrm'inu to catia:u, Y0f 1.25 2x 4 SP-N1 F' -E U.03 1351 C I ass Is deslgned for no Z 1 H W3 SL 1.05 2x10 SP-01 [ei li ng load. �/ 18G-RL8H-1 Oxl 4 W4 WS 18G-RL8H TL Dell -I.A8" Ix J -11 L/715 IIUIE: USER 110DIFIED PLATES L�� W -1 Oxl4I I Brace truss as fellow: LL Defl -1.39" is J -}[ L/881 This design may have Plates r ^ Z U.C. Fran f0 Shear // Grain is K -D 0.70 selected throu<lh a plate * O E 7C 2- 0- 0 0- U- U 29- 9- 1 nunil ur. _ BC 1- 6- 0 0- 0- 0 29- 9- 1 Plates for each ply each face. Max cwiµf. force '1693 Lbs IL W 1 PLATE V LUES MAY BE TPI. Duality Control Factor 1.01 LOattf luJ Live Dead (ps[) PLATE VALUES I�OtY DE VEItIF tED LG 1 LG2 Be 20:0 z:o WITH P ALUEESSBASED OEI SIG. Sp acI 26.0 6.0 08.0 Plate fd LUCOSS A20 TEST. O Sy acl nV 1U 8.0" Plate -LOCH 20 Ga, Grass Area Lu'her Duration Factor 1.15 Plate -to[$ 20 Gs, Gross Area K B 1 J 0.05202 I H G B2 Plate Duration Factor 1.15 Plate a lU IM 20 Ga, Gross Area L. - ®®® PC Fb=L 00 Fc=t.00 Ft=1.00 at'Typo 0.0 Size X Y .91 F I I llC FL-1.OU Fc-1.00 Ft-1.0U A LRLOHOCK l3.0s 14.011.1. 0 1.7 0.91 D LOCK 3.Ux 5.0 Ctr Ctr 0.<13 #SxI - #18G-RL8H-7xl 2- #5x7 - it React UDlft Size fteu'd CH LUCK 7.ox 9.0 Ctr-0.5 o.93 u J Lbs 11io In-Sx In-Sx D LOCK 3,Ox 1.0 Ctr Ctr 0.43 A 4214 U 5- 0 3- 9 E RL,R lU.Ux19.U-'1.'1 2.1 U.94 E 4284 U 5- 8 3- 9 K LOCH 5.Ox 7.0-0.1 Ctr 0.86 OH LOCK 5.Ox 7.0 Ctr Ctr 0.74 LLJ lfenitr CSI P Lb s Axl-CSI-Blu! ]IH 11L 8][ 7.Ox12.0 Ctr 0.1 0.78 BC 6- 9- 1 6- 3-13 6- 3-13 6- 9- 1 --------Tap CAnrds---------- GH LUCK 5.ox 7.O Ctr Ctr 0.64 A -U 0.95 '1693 C 0.13 0.02 F LOCH 5.Ox 1.0 0.5 Ctr 0.06 EP `r 8- 4-15 14- 8-12 000 21- 4- 1 28- 11- 2 p -, B -C 0.75 1111 C o.11 0.64 C -D o.75 '1111 C 0.11 0.64 11 -Plate Monitor used S L 22 0 6- 9- 1 6- 3-13 0 6- 3-13 6- 9.- 1 0 0 0 D -E 0.99 1693 C 0.13 0.82 `.... .--� .- --------Dottwn CAords--------- REFER TO RO11BI115 EMG. GF1fFRAL�^ CV K -J 0.89 71Q2 'P 0.99 0.51 DOTES ,llU) SY101ULS SHEET FOR ,V,•.•�.. ' ' �;;;. J -I[ 0.59 5566 T U.30 0.25 ADDI'TIODAL SYECIFICAIIURS. t[ -G 0.59 5566 T U.30 0.21 } G -F 0.89 7182 T 0.39 0.50 BOTES: Pao[ euJlea ihvw 114,11", Jleellly•Voitral S9:Doi 1:IIS IAW I;yt IIN^ Z 29-9- 0 ADDITIONAL 2x6 NAILER ' O -+1 `'; 30 S.C. 2090 TRUSS SCALE: 3/8"= P-0" N 20d R.S. NAIL THROUGH TO -' `�? STRAP INTO TIE 10 2x4 PURLIN (3) 1 1/2" R.S. NAILS THROUGH STRAP �� 2' LONG END BRACE STRAP Ji 1 1 ZO \ d (4) 2 1/4" R.W. NAILS 60d R.S. NAIL O n I i ' ® m TOP TRUSS CHORD 1_. 1 20 GA. GALVANIZED o - o; PURLIN CONNECTOR X � 0 2x4 TRUSS TIE ° L.LJ z 2x4 TRUSS TIE TO ENDWALL DETAIL (1) #9xl"TRU-GRIP SCREW ON PEAK SIDE AND -�^`� C-) w END TRUSS (2) #9x1"TRU-GRIP SCREWS ON EAVE SIDE OF a- PURLIN IN HOLES SHOWN (JOINT MUST BE TIGHT vi BEFORE FASTENING CLIPS) I I 1Fr g �J I � �J 2x4 BUTTED PURLIN DETAIL .q[ =4= > -4= I • I . • I . 1 01 1 0' 1 - 6-20d R.S. NAILS PER CONNECTION DRAWN BY. B. HAYES ' (2) 20d R.S. NAILS IN OVERHANG FRAME DA TE. 7/20/2006 CO�UMDN CHECKED BY. J. SMITH EXTENSION 2 x 4 BEV. PURLIN DATE: 8/21/2006 TOE NAIL OVERHANG RAFTER = I I TO OVERHANG NAILER WITH REVISED DATE.' 1/1 1i2oo7 B.D.H. (1) 16d R.S. NAIL EACH SIDE REVISED DATE. REVISED DATE: B 52 REVISED DATE.' <2> - I END 'TRUSS OVERHANG FRAME �tpMsap„ DETAIL # B 2x6 OVERHANG NAILER �0 t: k°v N,2 U 44 - �!- , A SCALE: 1 1/2"= 1'-0" (7) 20d R.S. NAILS ' � �• .0 TRUSS / BRACING PLAN k- 3-2x6 CORNER COLUMN R' full TRUSS / BRACING PLAN LEGEND 12 • o� 1 - 30' 2090 S.C. TRUSSES @ 7'-6" O.C. TYPICAL 2 - CONTINUOUS 2x4 LOWER CHORD TRUSS TIES 2' 8' APPROXIMATELY 3'-9"O.C. TYPICAL SCALE: =-� - 2x6 DIAGONAL END BRACES APPROXIMATELY 1' 4' 16' DETAIL #A r SCALE.-AS NOTED 7'-6" O.C. TYPICAL SHEET NO. SCALE: 1 1/2"= 1'-0" S 2 OF S 7 OFFICE: CUTCHOGUE, N.Y. JOB NO. 128-0788 0 cl- 0 co Lu 00 TO z z 2x4 PURLIN 2x4 TRUSS TIE 11 sQ 60d R.S. NAIL 60d R.S. NAIL USP RT4 HURRICANE ANCHOR O FASTENED TO TRUSS AND PURLIN W1(4) 0.131 2 x 1 1/2" R.S. NAILS 0 GA. GALVANIZED 20 ga.LOWER CHORD V) TRUSS PURLIN CONNECTOR GALVANIZED PURLIN CONNECTOR Y cQ Lai (1) #9xl"TRU-GRIP SCREW ON PEAK SIDE AND _B (2) #9xl"TRU-GRIP SCREWS ON EAVE SIDE OF (1) #9xl"TRU-GRIP SCREWS LLa ....PURLIN IN HOLES SHOWN (JOINT MUST BE TIGH .. BEFORE FASTENING CLIPS ....... T ON PEAK SIDE AND (2) ON EAVE SIDE IN HOLES SHOWN. ........... (JOINT MUST BE TIGHT BEFORE FASTENING CLIPS) 2x4 BUTTED PURLIN DETAIL 2x4 TRUSS TIE DETAIL Q ° `` Lij o 2� 0 _ o -� o #8X3 1/2" WOOD SCREWS 9 10" O.C. FASTENED THROUGH THE ALUMINUM DOOR SIDE JAMBS INTO THE 2x4 ROUGH FRAMING. PRE-DRILL HOLES IN ALUMINUM DOOR JAMB TO #8 x 3 1/2"WOOD SCREWS SPACED AS SHOWN ABOVE TO AVOID DOOR ACCEPT WOOD SCREWS. SCREWS ARE NOT REQUIRED IN THE HEAD OR THE SILL. IN SCREWS HEAD FLASHING 7116"OSB PANEL LJLJ rLu vi AA / 0 ULJ 2 DOORJAMB 2"x4" ROUGH FRAMING WALK DOOR JAMB DETAIL DRAWN 8 Y: B. HAYES DATE: 7/20/2006 Cf-IECKED BY: J. SMITH NOTE: DATE: 8/21/2006 DOOR PANEL AND WINDOW PROTECTION DETAILS ARE FOR INSTALLATION REVISED DATE.' 1/1 112007 B.D.H. INSTRUCTIONS ONLY, AND ARE NOT HEAD FLASHING PROVIDED OR INSTALLED BY MORTON 7116" OSB PANEL REVISED DATE: BUILDINGS' INC. OR MORTON BUILDINGS' DOOR SLAB REVISED DATE: SUBCONTRACTORS AND ARE THE OWNERS -V_ RESPONSIBILITY. REVISED DATE.' OSB PANEL IS I" WIDER THAN THE WIDTH OF THE DOOR ro- , FROM OUTSIDE OF TRIM TO OUTSIDE OF TRIM 1 o. WINDBOURNE DEBRIS PROTECTION - WALK DOOR WALK DOOR SECTION 07 rSCALE:AS NOTED LSHEET'N . S3 OF S9 �OFFICE.- CUTCHOGUE, N.Y. JOB NO. 128-0788 o r� c_ N o, 0 c_ w m C> 3'-0" WIDE 3.0' WIDE Z 3'-0" WIDE (ZONE 2) (ZONE 2 & 3) (ZONES 2 &3) C r Z (ZONE 2 & 3) __ i ., _ O �_ w (ZONE 3) (ZONE 1)�I VENT-A-RIDGE i 2QD (ZONE 2) 3.0' WIDE — 12 • Ttl i 6 GABLE TRIM C (ZONE 2 & 3) 1 4 (ZONE 3) — LJLJ 5"O.G. GUTTERS r HI-RIB STEEL :: HI-RIB STEEL �-•.J T#21 CORNER TRIM T#21 CORNER TRIM �. .1 > s T#167 TRANSITION TRIM T#167 TRANSITION TRIM HI-RIB EEL WAINSCOT WHI-RIB S STEEL WAINSCOT ci T#21 CORNER TRIM T421 CORNER TRIM T#167 BASE TRIM T#167 BASE TRIM . � F-- `''•mow':;<;. —"I I 39'-0" WIDE (ZONE 4) '1 I --i I .I I.— �) 3'-0" WIDE 3'-0" WIDE 3.0' WIDE 24.0 WIDE (ZONE 4) (ZONE 5) (ZONE 5) 3.0' WIDE 10 4 6 (ZONE 5) I (ZONE 5) � u � 37-0" 8'-0" 3 ~ / 6E _ 22'-0 1/2'' 7'-1 1 1/2" LO o o o O 4E 2 0Ln CO T ELEVATION ~ 'EA 2 N S N O 5 1 x NORTH ELEVATION O ° 3'-0" WIDE M W FRS 3.0' WIDE / i"� q: 3'-0" WIDE — (ZONE 2) (ZONE 2 & 3) (ZONES 2 & 3) t,,,,,,,✓ (ZONE 2 & 3) _ Reference _ v-� Z 1 (ZONE 1) I Corner 1--1—J = (ZONE 3) — VENT-A-RIDGE 2 � 3.0' WIDE w (ZONE 2) —� 1� T#16 GABLE TRIM (ZONE 2 & 3) 4 (ZONE 3) `J 5"O.G. GUTTERS .�" i HI-RIB STEEL HI-RIB STEEL " T#21 CORNER TRIM ^' T#21 CORNER TRIM DRAWN BY.• B. HAYES T#167 TRANSITION TRIM T#167 TRANSITION TRIM HI-RIB STEEL WAINSCOT HI-RIB STEEL WAINSCOT DATE.' 7/20/2006 T#21 CORNER TRIM T421 CORNER TRIM CHECKED BY.' T#167 BASE TRIM TO 167 BASE TRIM J. SMITH DATE: 8/21/2006 39'-0" WIDE ZONE 4 ( ) —•-I I �I REVISED DATE: 1/i 1/2007 B.D.H. I� 3-0 WIDE 3'-0" WIDE 24.0' WIDE (ZONE 4)(ZONE 5) (ZONE 5) REVISED DATE.' 3.0' WIDE 3.0' WIDE REVISED DATE.' 3'-6" � 41'-6" (ZONE 5) SOUTH ELEVATION (ZONE 5) L REVISED DATE.' o c� 0 WEST ELEVATION Lo Of _ • ,�'o' 2' 8' SCALE: dr , 'IT O 7, 4' 16' r g • NOTE: �`���arufiia�i�ir�'►"�� DOOR AND WINDOW LOCATIONS ARE TAKEN 01 , FROM THE EXTERIOR FACE OF THE NAILERS AND ARE TO THE CENTER OF THE DOOR AND WINDOW UNITS. VERIFY ALL LOCATIONS WITH THE OWNER. SCALE-AS NOTED SHEET NO. S4 OF S9 OFFICE: CUTCHOGUE, N.Y. JO8 NO. 128-0788 ® GABLE PURLIN FLASHING FF 2000 HI-RIB STEEL T#16 GABLE TRIM 2x4 PURLINS @ 23" O.C. IQ (4) 0.135"x 2 1/4" R.W. NAILS OR 16d R.S. NAILS ----•-�-- (NO. 2 SPF) TRUSS IN COLUMN 2x6 FASCIA R SADDLE 0 LAMINATED COLUMN FF 2000 HI-RIB STEEL T#194 TRIM —� USP RT4 HURRICANE (1) 20d R.S. NAIL THROUGH STRAP 2x4 PURLINS @ 23" O.C. SOFFIT ANCHOR 16 & INTO BRACE INSULATION STOP/ 50 (NO. 2 SPF) "����---- 2' END BRACE STRAP W/ PRE-PUNCHED Cl Q, AIR DEFLECTOR HI-RIB/SOFFIT CAP TRIM i /� HOLES (BEND TO FIT) FASTENED W/ 2x4 BEV. PURLIN 12 (3) 0.140 x 1 1/2" R.S. NAILS WIRE MESH 4 14 30' END TRUSS i ED FILLER STRIP � i 2x6 DIAGONAL BRACING FASTENED 2x6 BEV. FASCIA — USP RT4 HURRICANE ANCHOR 2-2x6 E.C.E. i i TO COLUMN W/(4) l 6d R.S. NAILS CD Z �� �� -` o ON ALL PURLINS go � - 30 2090' S.C. TRUSS Z 5" O.G. GUTTERS KYNAR HI-RIB STEEL 2x4 TRUSS TIE f 1 p T#144 & 146 FASCIA TRIM — 30' 2090 S.C. TRUSS _ _ _ _ _ _ _ _ _ ~ °- ( z I819 SOFFIT — ADDL. 2x6 NAILER HI-RIB/SOFFIT CAP INTERIOR HI-RIB STEEL R-19 BLOWN-IN INSULATION r ) 2x6 OVERHANG NAILER 4 MIL VAPOR RETARDER f ADDITIONAL 2x4 EXTERIOR NAILER �`^— l ADDITIONAL 2x4 EXTERIOR NAILER 2x4 TOP BLOCK & T#1 1 T#105 TRIM 2x4 NAILER W/T#1 1 T#105 TRIM (2) 1/2"x5 1/2" M. BOLTS & W (4) 20d R.S. NAILS [� KYNAR HI-RIB STEEL Q 3-2x6 LAMINATED COLUMN 1 1/4"xl 1/4"xl 4 GA. SUPPORT ANGLE `' Z s:;;:.�►'V""1 FASTENED TO COLUMN AT EACH U 0 CORNER WITH (3) .148"O x 2" p (6) ROWS 2x4 NAILERS STAINLESS NAILS. (12 TOTAL NAILS 3-2x6 LAMINATED COLUMN (2100 MSR @ 22" O.C.) PER COLUMN) :',:" 14 GA. CHANNEL WITH 1/4" PLATED V) (5) ROWS 2x4 NAILERS =:D o RIVET TO SUPPORT ANGLE !fi 14'-0" .J (2100 MSR @ 22" O.C.) I3 UNDISTURBED SOIL l L0 r GRADE TO HEEL J 06 STILT NOTES o 1. INSTALL PRESSURE TREATED C�! 0 2x2 VERTICAL BLOCKING LOWER COLUMN WITH STILT IN AT COLUMN LOCATION NOTE: °. ° THE AUGURED HOLE. Cls THUS SECTION IS THE SAME AS 2. POUR MINIMUM THICKNESS OF O X SECCTION "A" EXCEPT FOR READI-MIX CONCRETE INTO THE O T#167 TRANSITION TRIM THE ITEMS AS NOTED. ° HOLE AS SPECIFIED. nJ m 2x6 NOTCHED NAILER I1 3. BACKFILL AND COMPACT THE KYNAR HI-RIB STEEL WAINSCOT ANNULAR SPACE AROUND THE 5/4 BLOCK I COLUMN TO GRADE WITH SOIL �, z 7/16" OSB PROTECTIVE LINER 12 STILT ISOMETRIC M ETR I C l AUGURED FROM THE SITE. p l V) Tit 167 BASE TRIM W/L-CAP TRIM PROTECTOR L__J w (1) ROW 2x8 TREATED SPLASHBOARD 0 18" LOWEST l N• 1 0 MEMBER CUT-OFF �— 4" CONCRETE FLOOR♦ — �J " 18" LOWEST ---� <:;•> :;`.,,:::•.;y MEMBER CUT-OFF FINISH °° : °° 4" MINIMUM COMPACTED GRANULAR BASE GRADE CONCRETE FLOOR NOTES ° ° 1.)3500 PSI,5 1/2 BAG MIX CONCRETE. 2.)REINFORCING:6x6-10x10 WWM, 'a •'a 3.)SLOPE GRADE AWAY FROM BUILDING Q I"PER FINISH GRADE 4'-0" °.4 °.4 FOOT FOR A MINIMUM DISTANCE OF 10•PLUS OVERHANG WIDTH. DRAWN BY: B. HAYES '° •• 'd •• 4.)WHEN A VAPOR RETARDER IS PROVIDED,PLACE A MINIMUM 6 MIL POLYETHYLENE VAPOR RETARDER ON 5\ DATE: 7/20/2006 TOP OF A MINIMUM 4"COMPACTED GRANULAR BASE ° a AND DIRECTLY BELOW THE CONCRETE FLOOR. 4 0' SI\ lir CHECKED BY: J. SMITH ° 224M (14 GA.) COLUMN STILT 0 3j\ 3-2x6 LAMINATED DATE.' 8/21/2006 10"THICK MINIMUM READI-MIX CONCRETE BELOW SI,\ / COLUMN REVISED DATE.• 1/11/2007 B.D.H. ° BOTTOM OF LOWER COLUMN WITH ADDITIONAL 22 1 NAILS °. READI-MIX BACKFILLED TO 4" BELOW GRADE. 218M (14 GA.) COLUMN STILT ® 5''7 e 18 NAILS REVISED DATE. °. �8"THICK MINIMUM READI-MIX CONCRETE 5�. 40 NAILS "TOTAL s' PLACE CONCRETE BELOW AND ABOVE BOTTOM O ? �,/r REVISED DATE.• 24"O [BELOW BOTTOM OF LOWER COLUMN WITH LOWER COLUMN IN ONE OPERATION. ADDITIONAL READI-MIX TO TOP OF 218M STILT (9"±). / REVISED DATE. 16"O I (PLACE CONCRETE BELOW AND ABOVE BOTTOM OF cE ,}' (LOWER COLUMN IN ONE OPERATION. osEss` 00 . 4 ENDWALL SECTIION B INTERIOR . SCALE: 1/2" = 1'-0" NOTE: EXTERIOR • ' FOOTINGS ARE DESIGNED FOR A NAIL KEYe� �t>wx���,� 2000 PSF SOIL BEARING CAPACITY. NOTE: 0 0.148"x 4" (20d) NAILS Q� LOCAL CONDITIONS MAY REQUIRE S I D E W A L L S ECTI O N A ♦IDENTIFIES ITEMS THAT AIRS NOT PROVIDED • 0.131"x 3-3/4" (20d) SMOOTH SHANK GUN NAILS MODIFICATIONS. BY MORTON BUILDINGS, INC. OR MORTON COLUMN SPLICE FASTENING DETAIL SCALE: 1/2" = V-0" BUILDINGS' SUBCONTRACTORS AND ARE THE OWNER'S RESPONSIBILITY. SCALE: 1/2" = V-0" SCALE.-AS NOTED SHEET NO. J L S5 OF S9 OFFICE: CUTCHOGUE, N.Y. JOB NO. 128-0788 12 4� (2) 60d R.S. NAILS IN 3" OVERHANG RAFTER 6 2x6 UPRIGHT _ o 2x4 PURLIN CUT TO FIT BETWEEN OVERHANG FRAMES 2x10 TRACK GIRT (`.✓) `r KYNAR HI-RIB STEEL C1 10 (' V o C CI— o � w O ALIGN 50M BASE ANGLE WITH EDGE OF (3) 2xl2 BEAM t- 1 1" T#71 TRACK COVER w & BOLT THROUGH COLUMN & TRUSS WITH(l) 1/2"x5 1/2" M. BOLT (1/2" FLAT WASHER ON BACK SIDE ONLY). 30' 2090 S.C. TRUSS 51 M TRACK I 2x4 TOP X NO FASTENERS ARE REQUIRED DOWN INTO BEAM 3x4 TRACK BLOCK BLOCK & 14'-0" 1 1/2 x2 BLOCK & T474 T#1 1 TO GRADE 1 1 T971 TRACK COVER 200L TR SS HANGER 2x6 BLOCK 51 M TRACK ( W/(8) 1 1/2" R.S. NAILS f#23 JAMB TRIM 3x4 TRACK BOARD � (2) 2x4 TOP BLOCKS & T#1 1 T437 TRIM FASTEN BOTTOM OF TRUSS HEEL & BEAMW/ (1) 1/2"xl 2" 3 2x6 JAMB COLUMN I--' 14'-0" 1 1/2"x2" BLOCK LAG BOLT, 1 l" BELOW M. BOLT & 2 1/4" IIN FROM EDGE 2x3 JAMB (BEYOND; (BEYOND) w GRADE TO BOTTOM T#74 TRACKBOARD TRIM OF COLUMN (CENTERED ON 3-MEMBER BEAM). BOTTOM 2' TREATED) I i , OF TRACK GIRT T#25 JAMB TRIM (2) T#105 W (3) 2xl2HEADERS (NO. 1 SYP) SLIDING DOOR HEADER SECTION D 2x3 JAMB (BEYOND; 2xl2 TRACK GIRT (NO. l SYP) BOTTOM 2'TREATED) SCALE: 1" = 1'-0" 3-2x6 LAMINATED JAMB COLUMN BEYOND W/ AN ADDITIONAL 2x6 TREATED LAMINATE FOR HEADER SUPPORT Z SLIDING DOOR HEADER SECTION C C,.) J :y SCALE: 1" = 1'-0" �' CJ wZ � 0 u.a CJ cl)W C� O O o CQ c � o � Z w s w 2xl2 HEADER SPLICE AT JAMB N COLUMN. NAIL TO BEAM WITH (1) 20d R.S. NAIL EACH SIDE 20d GUN NAILS 4" O.C. STEP l: FASTEN TRUSS HEEL WITH STAGGERED &-TO COLUMN WITH ATTACH MEMBER #2 TO MEMBER #3 WITH STANDARD NUMBER OF 20d OF COLUMN SADDLE 1 10d R.S. GUN NAILS @ 8" O.C. STAGGERED R.S. NAILS PER SIDE ALIGN 50M BASE ANGLE WITH EDGE OF 3 2x12 ---� (5) 20d R.S. NAILS ° ° ( ) SET NAILS 2" FROM TOP AND BOTTOM BEAM & BOLT THROUGH OVERHANG RAFTERS & OF THE MEMBERS. TRUSS WITH (1) 1/2"x5 1/2" M. BOLT (1/2" FLAT WASHER ON BACK SIDE ONLY). NO FASTENERS ARE REQUIRED DOWN INTO BEAM. 2x3 JAMB CUT TREATED LAMINATE DRAWN BY: B. HAYES OFF AT BEAM SUPPORT ° ° DATE: 7/20/2006 STEP 2: CHECKED BY: J. SMITH ATTACH MEMBERS #1 AND #4 WITH 20d GUN DATE: 8/21/2006 OUTSIDE VIEW NAILS @ 4" O.C. AT TOP AND BOTTOM OF BEAM. SET NAILS 2" FROM TOP AND REVISED DATE.' 1/11/2ao7 B.D.H. 8„ BOTTOM OF BEAM. REVISED DATE.' CUT TREATED LAMINATE 8 (4) 2x12 BEAM REVISED DATE: OFF AT BEAM SUPPORT _ MEMBER #1 2x3 JAMB REVISED DATE: MEMBER #2 MEMBER #3 INSIDE VIEW_ MEMBER 44 .4% ?NtryqQ�� I' 4" *oz NAIL PATTERN PLAN VIEW NOTE: VIEWS ARE SHOWN WITHOUT OVERHANGS. l 4 -2xl 2 HEADER JAMB DETAIL SCALE:AS NOTED SHEET NO. S6 OF S9 OFFICE: CUTCHOGUE, N.Y. IIII DOUBLE TOP "D" RAIL IIII JOB NO.I 28-0788 KYNAR HI-RIB STEEL I (16 GUAGE) 60' END TRUSS I I 3-2x6 LAMINATED —`�I I 14 0 T##71 TRACK COVER 2-2x6 UPRIGHT TRACK GIRTLo 51 M TRACK JAMB COLUMN i STRUT i N TO GRADE ! ` (BEYOND) I 3x4 TRACK BOARD CL Os Os �---- HORIZONTAL"I"S.S. RAIL o LOP "D" RAIL (16 GUAGE) I I VERTICAL "I" RAIL --�� rj (0.06" WEB, 0.13" FLANGE) (0.09" WEB, 0.15" FLANGE) I w 1 1/2"x2" BLOCK TRACK GIRT I I T##74 TRIM i TO GRADE I I Z T#23 JAMB TRIM I i i Z I O s I I I Q I HORIZONTAL"I" I Q J LATCH HANDLE I I Q w I INTERMEDIATE RAIL 47E A/S LATCH STRIKE PLATE (0.06" WEB, 0.13" FLANGE) Wv w I I z Lu 2x3 JAMB 3-2x6 LAMINATED JAMB COLUMN i W/ 2x6x7' TREATED SPLICE STIFFENER I VERTICAL"I" RAIL (0.09" WEB, 0.15" FLANGE) LATCH HANDLE I p SLIDING DOOR HEADER SECTION I — SCALE: I" 1'-0" I ( O clff 1111-- Lo CENTER DOOR GUIDE DOUBLE BOTTOM "D" RAIL I N �( L J J (16 GUAGE) I _v 1--- O GRADE = Q� 7-4 1/2" 7-4-4 1/2" ''-u 0 cf/ o 14'-9" ca 0 x m SINGLE SLIDING DOOR FRAME (TWIN PANEL) �� Z I 1 1 s ® w w w — CENTER DOOR GUIDE V' i 3-2x6 LAMINATED U-i o 2 JAMB COLUMN _.J 1264 8" HOOK ++ INSTRUCTIONS DRAWN 8Y. B. HAYES VERTICAL"I" RAIL 1. SCREW NUT ONTO HOOK. DATE: 7/20/2006 LATCH HANDLE 2. SCREW HOOK INTO LATCH BODY. DOOR GUIDE DETAIL CHECKED BY; J. SMIfH —� 47E A/S LATCH STRIKE PLATE DATE.' 8/21/2006 REVISED DATE.' 1/11/2007 B.D.H. REVISED DATE: HORIZONTAL INTERMEDIATE"I" RAILS 3/8" JAM NUT REVISED DATE: NOTES: REVISED DATE.' 1.) VERIFY IF DOOR IS SINGLE OR TWIN PANEL ON ALUMASTEEL DOOR REQUEST SHEET. 2.) CHANGE HEIGHT AND WIDTH OF SLIDING DOOR e, f NEW Tt*, ON ELEVATION AND SECTION. (DRAW DOOR TO SCALE) Or 1265 JAMB LATCH BODY 12'xl2' SINGLE SLIDING DOOR OUTLINE SHOWN. �. •O +�{j •�' ' 3.) DETERMINE # OF INTERMEDIATE RAILS, JAMB DETAIL S.S. RAILS (STRUT RAILS), RAIL THICKNESS, & STRUTS FROM CHECKLIST & CHART. ` (SEE ALSO CPM PAGE 20-27) I 4.) CHECK SECTION FOR ACCURACY TO YOUR SITUATION. NOTE: V LATCH HANDLE its . � '� t" ♦ IDENTIFIES ITEMS THAT ARE NOT PROVIDED BY MORTON BUILDINGS, INC. RAIL THICKNESS CHART OR MORTON BUILDINGS' SUBCONTRACTORS STANDARD HEAVY AND ARE THE OWNERS RESPONSIBILITY. VERTICAL _EEEHORIZONTAL VERTICAL i 10RIZDNTAL SCALE:AS NOSED WEB FLANGE WEB FLANGE WEB FLANGE WEB FLANGE .070" 090" 1 .060" 1 .080" .090" .150" .060" .130" SHEET NO. S7 OF S9 OFFICE: CUTCHOGUE, N.Y. JOB NO. 128-0788 o �r cl, co N Q� 1 0 cl- -`1 w �✓ m O z z w �� Z (��Jl O O LOWER CHORD OF 7/16" OSB END TRUSS--7Z M� �-�J STD. 2x4 BUILDING NAILERS / I— — — — — — — — — — — — — — — — — — ...... - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2x6 VERTICAL BLOCKS Q `.-- z COLUMN BETWEEN NAILERS 2x6 BLOCK BETWEEN NAILERSci NAILED TO COLUMN W/20d = - - — - GUN NAILS. NAILED 3" O.C. © '"`j O o _ _ _ _ _ _ _ _ _ _ _ _ _ _ PERIMETER OF 05B SHEETS EXTRA NAILERS ADDED NAILED W/1-3/4"SHINGLE a BETWEEN STD. NAILERS GUN NAILS SPACED 3" O.C. (MAX. SPACE TO BE 24") l I 1 - - - - - - - - - - - - - - - - - - LAMINATED COLUMN �� _ _ _ _ _ _ _ _ _ _ _ . .._ _ _ _ _ Q OSB NAILED TO INRERMEDIATE ;E SUPPORTS W/1-3/1' SHINGLE u GUN NAILS SPACEID 6" O.C. _ _ _ _ — - - - _ _ o � m 2x4 NAILERS r 00 7/16" OSB - - - - - - - - - - - - - - - - - - LAMINATED COLUMN --- � - - - - - - - - - - - - - - - - - - LAMINATED COLUMN z LJLJ = _ _ _ _ _ _ _ _ _ _ _ _ _ _ OSB SHEARWALL DETAIL a_ - - - - - - - - - - - - - - - - - - SCALE: 1/2" = 1'-0" vi 5/4x6 NAILER LTJ g (IF PROTECTIVE LINTER 15 INCLUDED) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2x8 TREATED BASEBOARD DRAWN 8Y: B. HAYES DATE: 7/20/2006 CHECKED BY: J. SMITH DATE: 8/21/2006 REVISED DATE.- 1/11/2007 B.D.H. OSB SHEARWALL ELEVATION REVISED DATE.' SCALE: 1/2" = 1'-0" REVISED DATE.' REVISED DATE.' ,.Oo • + �A•��r q(t{tttt� OI . SCALE:AS NOTED SHEET NO. S8 OF S9 OFFICE: CUFCHOGUE, N.Y. JOB NO. 128-0788 o (4) Q_ 10 N C� ^^ ., O uj LLB OZ (� W Z a. O � LJLJ a'�-�yW ROOF STRUCTURE FASTENING SCHEDULE (D Q VENT-A-RIDGE TO RIDGE BASE TRIM #9 x 1"STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS @ 8"o.c. ` Z RIDGE BASE TRIM TO 2x4 PURLINS #9 x 2"STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS AT EVERY HI-RIB (1'-0"o.c.) r 1 c V ..... Q HI-RIB STEEL TO 2x4 PURLINS #9 x 2"STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS AT EVERY HI-RIB (1'-0" o.c.) i ® 20 ga. GALVANIZED PURLIN CONNECTORS #9 x 1"TRU-GRIP SCREWS �G.�, Ar 2x4 PURLINS TO TRUSS 0.200"x 6'' (60d) RING SHANK NAILS IN PRE-DRILLED HOLE \ O © RT4 HURRICANE ANCHOR TO 2x4 PURLINS (4) 0.135 (8d) x 1-1/2" RING SHANK NAILS \ '� (Di RT4 HURRICANE ANCHOR -TO TRUSS (4) 0.135 (8d) x 1-1/2" RING SHANK NAILS ~� Ln (2) 1/2"x5 1/2" MACHINE BOLTS -' ® 30' STRAIGHT CHORD TRUSS TO COLUMN (4) 0.177"x 4" (20d) RING SHANK NAILS O WALL FRAMING FASTENING SCHEDULE � COLUMN STILT (14 GA.) TO COLUMN (12) 0,148"x 2" (6d) STAINLESS STEEL RING SHANK NAILS xp io 2x8 SPLASHBOARD TO COLUMN (4) 0.177"x 4" (20d) STAINLESS STEEL RING SHANK NAILS @ SPLICE/ (3) 0.177"x 4" (20d) RING SHANK NAILS @ STANDARD CONNECTION 2x6 NOTCHED NAILER TO COLUMN (4) 0.148"x 3-1/2" (16d) NAILS @ SPLICE/ (3) 0.148"x 3-1/2" (1(6d) NAILS @ STANDARD CONNECTION ( a: 7/16" OSB TO SPLASHBOARD & NOTCHED NAILER 0.099"x 1-1/4"ASBESTOS SIDING NAILS is 2x4 NAILER TO COLUMN (4) 0.148"x 3-1/2" (16d) RING SHANK NAILS @ SPLICE/ (3) 0.1/18"x 3-1/2" (16d) RING SHANK NAILS @ STANDARD CONNECTION Z 9 END TRUSS TO 2-2x6 END COLUMN EXTENSIONS (6) 0.177"x 4" (20d) RING SHANK NAILS l l l a 2x4 PURLIN TO END TRUSS 0.200"x 6" (60d) RING SHANK NAILS IN PRE-DRILLED HOLE (L ie RT4 HURRICANE ANCHOR TO END TRUSS (4) 0.135" (8d) x 1-1/2" RING SHANK NAILS o HI-RIB STEEL TO NAILERS #9 x 2"STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS AT EVERY HI-RIB (1'-0" o.c.) L-JLJ 0 �a SOFFIT TO WALL INSERTED IN PRE-FORMED SLOT IN SOFFIT/HI-RIB CAP i9 SOFFIT TO FASCIA T-50 MONEL STAPLES (2) PER PIECE 7/16" OSB SHEARWALL - OSB TO PERIMETER BLOCKS/ FRAMING 0.120"x 1-3/4"SMOOTH SHANK SHINGLE GUN NAILS @ 3" o.c. OSB TO INTERMEDIATE FRAMING 0.120"x 1-3/4"SMOOTH SHANK SHINGLE GUN NAILS @ 6" o.c, © BLOCKS TO COLUMNS 0.131"x 3-3/4" (20d) SMOOTH SHANK GUN NAILS @ 3"o.c. DRAWN BY: B. HAYES DATE: 7/20/2006 CI-IECKED BY: J. SMITH DATE: 8/21/2006 REVISED DATE.' 1/1 1/2007 B.D.H. REVISED DATE.' REVISED DATE.' REVISED DATE: 1�'�lWI41),+p� I * .0 _ twit SCALE:AS NOTED SHEET NO. S9 OF S9 OFFICE.• COMPLY WITH ALL CODES OF nooD ZONE, CUTCHOGUE, N.Y. MORTON BUILDINGS GENERAL SPECIFICATIONS APP UE�AS NOTED NEW PORK STATE TOWN CODES FOOD DAMAGE P VENTION JOBN0.128 0788 _ _ AS REQUIRED AND CONDITIONS OF LAMINATED COLUMNS- NO. 1 OR BETTER SOUTHERN YELLOW PINE NAIL LAMINATED 3 MEMBER S4S DATE' �Z d B.P.#yL� 31 SOU` OLD TOWN ODE. COLUMNS USED IN MORTON BUILDINGS ARE PRESSURE TREATED BELOW GRADE TO A RETENTION OF.8 FEE:. � )�' BY: �2" U -� soy I. Ho!D TO'NN PLANNING BOARD POUNDS PER CUBIC FOOT WITH CHROMATED COPPER ARSENATE TYPE III, OXIDE IN CONFORMANCE NOTIFY BUILDING DEPARTMENT AT 765-1802 8 AM TO 4 PM FOR THE ..�,. SOUTHC�LD i01tif'J TRUSTEES USEPA GUIDELINES AND AWPA STANDARD C28. THE TREATED PORTION OF THE COLUMN FOLLOWING INSPECTIONS: N.Y.S. EC UNDERWRITERS CERTIFICATE r EMBEDDED IN GROUND SHALL BE LAMINATED WITH STAINLESS STEEL NAILS. 'I. FOUNDATION - TWO REQUIREDREQUIRED �+..•/ FOR POURED CONCRETE ` 2. ROUGH - FRAMING & PLUMBING FOOTINGS AND ANCHORAGE-COLUMN HOLES ARE DUG A MINIMUM DEPTH OF 4'-8"BELOW GRADE 3. INSULATION ALL CONSTRUCTION SHALL (SEE PLANS FOR DIAMETER AND DEPTH).COLUMNS WITH GALVANIZED SUPPORT STILTS ARE PLACED IN 4. FINAL - CONSTRUCTION MUST `. EET THE REQUIREMENTS OF THE THE HOLE.CONCRETE (MINIMUM COMPRESSIVE STRENGTH 2500 PSI) IS POURED IN PLACE TO THE BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET T CODES OF NEW PORK STATE. SPECIFIED THICKNESS (SEE PLANS FOR REQUIRED THICKNESS ABOVE AND BELOW THE COLUMN).THE REQUIREMENTS OF THE CODES 0 COLUMN IS THEN BACKFILLED WITH SOIL AND COMPACTED AT W INTERVALS OR BACKFILLED WITH If YO R's STATE If NCRAWWO1 L� LESEN OR VI TIC CONCRETE (SEE PLANS). A mh� UNOFf TREATED LUMBER-PRESSURE PRESERVATIVE TREATED LUMBER OTHER THAN LAMINATED COLUMNS ARE RETAIN STORM WATER 5-IOG NO. I OR BETTER SOUTHERN YELLOW PINE AND CENTER MATCHED OR NOTCHED AND GROOVED, PURSUANT NODE.SECTION 45-1C1C PRESSURE TREATED TO A NET RETENTION OF A POUNDS PER CUBIC FOOT WITH A CODE AND INDUSTRY OF THE TOWN CODE. rae APPROVED PRESERVATIVE TREATMENT IN ACCORDANCE WITH AWPA USE CATEGORY UC4A. V >�N �t �1 t ' ` L FRAMING LUMBER-SIDING NAILERS ARE 2x4 S4S OR 2x6 SPF NO. 2 OR BETTER SPACED APPROXIMATELY � I�,��.-PNFUL SE IS 36"O.C. WITH ALL JOINTS STAGGERED AT ATTACHMENT TO COLUMNS. ROOF PURLINS ARE 2x4 S4S NO. W� �.)UT C)'E �TIFICATE ,� P XIMAT LY 4" O+C,ALL OTHER FRAMING LUMBER IS NO, 2 CIF( VV :2I�,j2 Oft �twTTEI'i �►N EDGC SPACED AP RG� E 2 ... BETTER. O F I { Z ROOF TRUSSES- FACTORY ASSEMBLED WITH 18 OR 20 GAUGE GALVANIZED STEEL TRUSS PLATES AS t 1 c \J REQUIRED AND KILN DRIED LUMBER AS SPECIFIED, IN-PLANT QUALITY CONTROL INSPECTION IS i :- CONDUCTED UNDER THE AUSPICES OF THE TPI INSPECTION BUREAU. TRUSSES ARE DESIGNED IN _ !, ACCORDANCE WITH CURRENT STANDARDS AND SPECIFICATIONS FOR THE STATED LOADING. '� O { N SIDING PANELS (KYNAR 500/ HYLAR 5000) -0.019"MIN., G90 GALVANIZED OR AZ55 GALVALUME, WITH AN ADDITIONAL BAKED-ON KYNAR 500/ HYLAR 5000 FINISH WITH A NOMINAL 1 MIL. PAINT THICKNESS C. ON EXTERIOR. ROOFING PANELS (FLUOROFLEX 2000'rm) -0.019"MIN.AZ55 GALVALUME WITH AN ADDITIONAL _ BAKED-ON THICKNESS POLYURETHANE PRIMER AND KYNAR 500/HYLAR 5000 TOPCOAT WITH A TOTAL 131,11LDli`dG DESIGN CRITERIA MINIMUM PAINT THICKNESS OF 2 MILS ON EXTERIOR. BUILDING CODE 2003 BUILDING CODE OF NEW TRIM-DIE-FORMED TRIM OF 0.019"MIN., G90 GALVANIZED OR AZ55 GALVALUME STEEL ON GABLES, YORK STATE USE GROUP U RIDGES, CORNERS, BASE WINDOWS,AND DOORS WITH SAME FINISH AS ROOFING OR SIDING PANELS. CONSTRUCTION TYPE VB t.✓ FLOOR AREA 1350 SQ FT GUTTERS -5"K-STYLE, .030 HIGH TENSILE ALUMINUM GUTTER, KYNAR 500/HYLAR 5000 FINISH TO MATCH MEAN ROOF HEIGHT 18.0 FT TRIM, ON BOTH SIDES OF THE BUILDING. BUILDING CATEGORY IV ROOF SNOW_ LOAD'* 29 P5F_ ADDITIONAL NOTES GROUND SNOW LOAD 45 PSF 1.) ALL PLOT PLANS AND RELATED DETAILS SHALL BE PROVIDED BY OWNER UNLESS INCORPORATED WIND SPEED (Vas) 120 MPH Lu AS PART OF THESE DRAWINGS. WIND IMPORTANCE FACTOR 0.77 2.) ALL INTERIOR PARTITIONS AND ROOM FINISHES IF NOT INCLUDED WITH THESE DRAWINGS SHALL BE EXPOSURE CATEGORY C PROVIDED BY OWNER,STANDARD FINISHES SHALL HAVE LESS THAN 200 FLAME SPREAD RATING AS INTERNAL PRESSURE COEFFICIENT t0.18 REQUIRED BY ASTM E84 FOR ORDINARY CONDITIONS AND 25 OR LESS FOR EXITS, PASSAGEWAYS, BUILDING DESIGN CONDITION ENCLOSED WIND LOAD DESIGN ASCE 7 METHOD 2 AND CORRIDORS. ZONE 1 E 20.5 PSF rw-- 3.) FLOOR COVERINGS JUDGED TO REPRESENT AN UNUSUAL HAZARD SHALL MEET THE SAME TESTING ZONE 2E -26 6 PSF DRAWN BY.' B. HAYES PROCEDURES AS REQUIRED FOR WALL AND CEILING FINISHES. ZONE 3E -- -18 2 PSF DATE: 7/20/2006 4.) MORTON BUILDINGS GENERAL SPECIFICATIONS APPLY UNLESS INDICATED DIFFERENTLY ON ZONE 4E -17.0 PSF CHECKED BY.' J.SMITH SPECIFIC JOB DRAWINGS OR SUPPLEMENTAL INFORMATION. ZONE 5E 16.8 PSF DATE.' 8/21/2006 5.) KYNAR 500 IS A REGISTERED TRADEMARK OF ATOFINA CHEMICAL, INC., HYLAR 50WO IS A MAIN WES ACT NOR RESISTING SYSTEM ZONE 6E -13.0 PSF (ALL FORCES ACT'NORMAL TO THE SURFACE] REVISED DATE,' TRADEMARK OF SOLVAY SOLEXIS. (FOR ZONES SEE MWFRS ON ELEVATIONS PAGE) ZONE 1 14.8 PSF (MAXIMUM VALUE SHOWN) REVISED DATE.' ZONE 2 -18.5 PSF 2x4FK 11/05 ZONE 3 -13.8 PSF REV/SE©DATE' ZONE 4 -12.7 PSF REVISED DATE.` TYPICAL LUMBER SPECIFICATIONS-2001 NDS ZONE 5 12.4 PSF INDEX SIZE DESCRIPTION BENDING VALUE Fb I HEREBY CERTIFY THAT THE STRUCTURAL DESIGN FOR SHEET 2x4 NO. 1 &2 SPF 1313 PSI ZONE 6 -10.0 PSF THIS BUILDING WAS PREPARED BY ME OR UNDER MY 2X4 2100f MSR SPF 2100 PSI ZONE 1 144 -23.5 PSF DIRECT SUPERVISION AND THAT I AM A SHEET# DESCRIPTION 2x6 NO. 1 &2 5PF 1138 PSI COMPONENT&CLADDING WIND LOADS ZONE 2 14.5, 41.0 PSF LICENSED/REGISTERED PROFESSI G1 OF G1 SPECIFICATIONS &SHEET INDEX 2x6 NO. 1 SYP 1650 PSI (ALL FORCES ACT NORMAL TO THE SURFACE) ZONE 3 14.5, -41.0 PSF S 1 OF S9 COLUMN PLAN (FOR ZONES SEE ELEVATIONS) r 1 G + S2 OF S9 TRUSS PLAN,TRUSS DRAWING, & DETAILS 2x8 NO. 1 SYP 1500 PS{ ZONE 4 2�.1,-27.9 PSF (Ie% 2x10 NO. 1 SYP 1300 PSI ZONE 5 25 , -345 PSFS3 OF S9 TRUSS DETAILS &WINDBORNE DEBRIS DETAILS 1 . RONALD L.S 2x12 NO. 1 SYP 1250 PSI DATE: •` , z Z- S4 OF S9 ELEVATIONS ALL 1950f MSR SYP 1950 PSI * ROOF SNOW LOAD CALCULATIONS S5 OF S9 SECTIONS &DETAILS 1 I/2'xl61 LAMINATED VENEER LUMBER 28W PSI S6 OF S9 SECTIONS 3 1/2'Sc15" GLU-LAM 1650 PSI PS = 0.7 x Ce X I X Pg x Ct x CS S7 OF S9 SINGLE SLIDING DOOR DETAILS 5 1/4"XI6 1/2" GLU-LAM 2400 PSI Ce = SNOW EXPOSURE FACTOR= 1.0 WARNING: I = IMPORTANCE FACTOR = 0.8 IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY S8 OF S9 SHEARWALL DETAILS 5 1/4'x19 1/T GLU LAM 2400 PSI Pg = GROUND SNOW LOAD = 45 PSF PERSON UNLESS ACTING UNDER THE DIRECTION OF THE S9 OF S9 FASTENING SCHEDULE NOTE:HIGHER GRADE MATERIAL REQUIRED AS NOTED ON PLANS. Ct = THERMAL FACTOR = 1.2 LICENSED ARCHITECT OR LICENSED ENGINEER TO SCALE.'AS NOTED Cs = ROOF SLOPE FACTOR =0.94 ALTER ANY ARCHITECTURAL OR ENGINEERING ITEM. SHEET NO. Ps = 0.7x1.0x0.8x45x1.2x094=28.43PSF G1 OF GI COFFICE., CUTCHOGUE, N.Y. LJO, NO. 128-0788 . o `t c� N Ol ., O OC Lu OZ ( w Z IL cl+ L.I J V O H COLUMN PLAN LEGEND ° ❑ - 3-2x6 LAMINATED COLUMN LOCATION (E--- 10 ❑ -3-2x6 LAMINATED COLUMN LOCATION W/ _ y Ll � 4'-0" EMBEDMENT BACKFILLED TO 4" BELOW GRADE VU Z e - HEADERED TRUSS LOCATION O - (1) 3068 9-LITE FIBERSTEEL WALKDOOR W/LOCKSET O � - (1) 14'-9"x I 4' TWIN PANEL SINGLE SLIDING END DOOR (� 0 - (1) 15'xl 4' TWIN PANEL SINGLE SLIDING SIDE DOOR �� �� - (4) 3065 SKYLITES (VERIFY LOCATIONS)s0- 7/16" OSB SHEARWALL (SEE DETAIL SHEET S8 OF S9) 2 �v (T 16"R - 16" DIAMETER FOOTING W/ oX 8"THICK MINIMUM READ]-MIX CONCRETE cn `? `� BELOW BOTTOM OF LOWER COLUMN WITH �/ O o �' N N "�' ADDITIONAL READI-MIX TO TOP OF 218M STILT (9"±), ( � a PLACE CONCRETE BELOW AND ABOVE BOTTOM OF 15'-3" 7'-1 1/2" 7'-6" 7-6" 7-4 1/2" LOWER COLUMN IN ONE OPERATION. 16"W - 16" DIAMETER FOOTING W/ Z MIX (5)50# BAGS OF SACKRETE WITH 2-1/2 1-1 '1 V) 1'-0"VENTED SIDEWALL OVERHANIGS GALLONS OF WATER. PLACE CONCRETE BELOW Q w C A AND ABOVE BOTTOM OF LOWER COLUMN IN °- S6 55 l'-0"NON-VENTED ENDWALL OVERHANGS ONE OPERATION. USE 218M STILT. (CONCRETE MINIMUM COMPRESSIVE STRENGTH = 2500 PSI) ( I 1 g — 24"R - 24" DIAMETER FOOTING W/ 1 29'-9" - - 29' 9" ■ - - 10"THICK MINIMUM READI-MIX CONCRETE 16"W 30"R Q 24"R 24"R 24"R 16"W BELOW BOTTOM OF LOWER COLUMN WITH ADDITIONAL READI-MIX TO TOP OF 224M STILT (9"±). C A s PLACE CONCRETE BELOW AND ABOVE BOTTOM S6 SS OF LOWER COLUMN IN ONE OPERATION. 22'-4 1/2" — I 16"R 16"R I — 22'-4 1/2" 30"R -30" DIAMETER FOOTING W/ 13"THICK MINIMUM READI-MIX CONCRETEr BELOW BOTTOM OF LOWER COLUMN WITH eDRAWN BY; ^ B. HAYES 19 s B B ADDITIONAL READI-MIX TO TOP OF 230M STILT (9"±). - S5 V ^ PLACE CONCRETE BELOW AND ABOVE BOTTOM DATE.' 7/20/2006 OF LOWER COLUMN IN ONE OPERATION. CHECKED BY: J. SMITH 14'-11 1/2" 16"R 16°R -�-- - - 14'-10 1/2" ROUGH OPENING SCHEDULE DATE: 8/21/2006 REVISED DATE.' UNIT SYMBOL � I FROM LEGEND WIDTH HEIGHT REVISED DATE: D D S6 S6 16"R — — 7'-41/2" REVISED DATE; � 38 1/4" 81" v I = REVISED DATE.' CV 16"1 24"R 24"R 24"R 24"R 24"R 16"W ;� � �'O l• S' �� 0'-0,1 01-01, q ti 7-4 1/2" 7'-6" 7-6" 7-6' 7-6" 7-4 1/2" 08 . Z3 t)t) o o N CN o 2' 8' SCALE: 1' 4' 16' SCALE. AS NOTED COLUMN PLAN SHEET NO. __j L-S 1 OF S 9 FOFF17CE.'SL 15-8-2 SL 15-8-2 HOGUE, N HO1-3-8 HO1-3-8 SL 7-11-2 7-9-0 7- 9-0 7-11-2 TRUSS DESIGN LOAD =288 PLF JOB NO. 128-0788 EP 7-6-4 14-10-8 22-2-12 29-9-0 REQUIRED TRUSS LOAD = 33 PSF AT 7'-6" O.C.=247.5 PLF TC 7-6-4 7-4-4 7-4-4 7-6-4 ..��. LIVE LOAD 29 PSF #7x9 = DEAD LOAD 4 PSF C CEILING LOAD - PSF 4 (- 301 S.C. 2090 TRUSS TOTAL LOAD 33 PSF C R.bbl-6yineerina. I..30.11..Plus" APPROX. TRUSS SCUM: 171.3 LSS 3X5 \\ 3x5 // oz,3nn, -------------Meba------------- Trusses Baxafactared by: B -J 1.18 1298 C Nurtoa Balldings, Inc. D Unlixa bits -- Versiox 19.8.618 J -C a.25 1415 T Analysis Coxfursw To: B HN D : il-NAY-e4 It -C 6i4 42e T AfSI/TPI 95 4 12 C -G 1.25 lit:T Ran vertical thra bottom chord TI T2 CSI -Slro- ----Loader---- G -D rule 129C Joint H TC 1.95 2x r SP-2411 -----------Sliders------------ Prewxt trams rotation at all f 6-3-0 W Bc run 2x a Sr-24r1 A -x 1.05 1311 C bearinit locations. (\ Ul 1.23 Px 4 Sr-R1 P -E 8.13 1351 C Irma is desigxed for so SL 1.r5 2xla SPI ceiling load. 1 2H W3 TL Deft -8.431 in J -H L/T15 BOTE: USER xUDIFIP.D PLATES W4 W5 18G-RL8H-1 Ox14 I I Brace trvs as follow: LL Defl - t.39• in J -H L/aei Tkis design Play have Plates 1$G-RL$H-1 OX14 I I O.C. rrom To shear //Grain is IC -a e.11 selected through a plate I 29-TC 2- i- 1 r- r- 9- 1 "Ititor. A E SIC T- e- 1 e- r- r 29- 9- r Plater for each ply each face. ]tax coop. force 1493 lb■ PLAY11W CU14URKS TO TPI. Uvallty Control ractur 1.11 W 1 Load1w Live Dead (paf) PLATE VALUES MAY BE VERlrlW LG2 LG 1 TC 2r,a 4.r WITH ROOOIItS ERG12MMUNG. aC r./ 2.e GRIP VALUES BASED ON Sr Total 24.9 6.0 32.1 USIRG GROSS AMA TEST. Spaclag 111.r' Plate -LUCK 2e Ga, Gross Area Lumber Duration rector 1.15 Plate -MS 2r Ga, Gross Area ,® ry� Plate D�[..rector 1.75 Plate -H.IH 2e Ga, Groaa Area Bl - 0.05202 - B2 TC tb-i.ra rc=l.ea Ftal.ea Jt RL at Ylt1.9 Sim X Y J51 K J i H G F ac rn-lure ro.l.ee Ptrl.er A LOCK 11.ax14.e11.r 1.7 r.91 �...,, D Loaf 3.rx 5.a Ctr Ctr muss ///•��� �,, #5X7 - Jt React ublft SixeRea TA-Sx Cr LOCTC T.ex I.a Ctr-*.5 a.43 1 y #1$G-RL$H-7x12= #5x7 - lbr tbue In-sx In-sx D LOCK 3.ex 5.r Ctr Ctr 1.43 A 4284 a 5- 1 3- 9 E H.pt 19.ex14.r-1.1 2.a r.94 E 42e4 a 5- r 3- 9 N LUCK 7.ax T.r-a.5 Ctr 1.a4 Jr LOCK 1.ex T.a Ctr Ctr e.T't Hesbu CSI T Lbs AYL-CSI-and Itr not T.vxu.o Ctr s.9 cis BC 1 6-9- 1 1 6-3-13 1 1 6-3-13 1 6-9- 1 ----------Top Chords---------- GO LOCK I.Ox 7.4 Ctr Ctr 0.44 A-a r.95 1493 C 8.13 4.12 F LOCK 5.rx 7.0 1.5 Ctr 1.14 EP d;d 8-4-15 14-8-12 0 21-4- 1 28- 1-2 `r `t a -C r.T5 Trn c mull e.44 (y) 'r .-• C -D 1.T5 T1T3 C r.il r.r4 D -Plate Nonttor Bred 9.5L �o 6-9- 1 6-3-13 6-3-13 6-9- 1 O - __ --Botty^Chords-19------ REM To ROOVINS EM. GENERA. I{I 2_ ^ '"' N K -J r.e9 T112 T r.39 e.5r NOTES Alm symois smi Putt J -b( r.51 5144 T r.30 r.29 ADDITIONAL SPECIFICATIONS. ILw.J H-G 659 3544 T r.3i a.29 - G -F 1.69 '1182 T 5.39 1.58 KUM: AIG1 9V_$11f.%0A1%W?)K-0"96[ Wn10I*.O018Egkk4r*j-FM&t 52tldFJNINAa Pap:012 Z ;y...0 29-9-0 D X ADDITIONAL 2x6 NAILER 30t S aC a 2090 TRUSS SCALE: 3/6'= V-9' 20d R.S. NAIL THROUGH STRAP INTO TIE 2x4 PURLIN (3) 1 1/2"R.S. NAILS THROUGH STRAP d � 2' LONG END BRACE STRAP ' (4) !2 1/4"R.W. NAILS d 60d R.S. NAIL cl ( uj TOP TRUSS CHORD - 20 GA. GALVANIZED PURLIN CONNECTOR 2x4 TRUSS TIE o +� U 2^4• TRUSS TIE TO EN DWALL DETAIL (1) #9x1"TRU-GRIP SCREW ON PEAK SIDE AND END TRUSS (2) #9ac1"TRU-GRIP'SCREWS ON EAVE SIDE OF -�,~�` PURLIN IN HOLES SHOWN (JOINT MUST BE TIGHT BEFORE FASTENING CLIPS) 2YA BUTTED PURLIN DETAIL01 -� � I I 6-20d R.S. NAILS I FAWN BY.' B. HAYI - - -�- - I PER CONNECTION (2) 20d R.S. NAILS IN OVERHANG FRAME DATE.' 7/20/2t 3 a 2-2X6 END CHECKED BY.' J.SMITI ICOLUMN EXTENSION 2x4 BEV. PURLIN DATE: 8/21/21 X TOE NAIL OVERHANG RAFTER REVISED VAl`& TO OVERHANG NAILER WITH (1) 16d R.S. NAIL EACH SIDE REVISED DATE.' IREVISED DATE.' B iI S2 �\�I REVISED C1ATE.' - 7` _ I OVERHANG FRAME oe�M�u D ETAI IL #B END TRUSS 2X6 OVERHANG NAILER �a�.<<G a J-a✓® A SCALE: 1 1/2"= 1'-0" (7) 20d R.S. NAILS '���� • �' S� ` S2 r ,D r9k TRUSS / BRACING PLAN �® • '� . ' 3-2x6 CORNER COLUMN - � rri)t r1 r TRUSS / BRACING PLAN LEGEND o6 , , 1 -30'2090 S.C.TRUSSES 0 7'-6"O.C.TYPICAL CONTINUOUS 2x4 LOWER CHORD TRUSS TIES 2' 8" APPROXIMATELY 3'-9"O.C.TYPICAL SCALE: 1' 4' 16, DETAIL #A SCALE. AS NOTED Q -2x6 DIAGONAL END BRACES APPROXIMATELY SHEET NO. 7'-6"O.C.TYPICAL " 1� SCALE: 1 1/2 = -0' ,J.G. OFFICE: CUTCHOGUE, N.Y. JOB NO. 128-0788 Ir OL W ro \rrI Z lu ''�' z 1 p 2x4 PURLIN R Ise ' 2x4 TRUSS TIE II r sQ 60d R.S. NAIL 60d R.S. NAIL II a 6 r USP RT4 HURRICANE ANCHOR FASTENED TO TRUSS AND PURLIN 20 ga. / W/(4) 0.131"x 1 1/2" R.S. NAILS 20 GA. GALVANIZED LOWER TRUSS CHORD o GALVANIZED I•-r TRUSS p• \ \ Lij PURLIN CONNECTOR • � � � PURLIN C1/ 1 � � CONNECTOR �L.1;.'J; -•� • O n � %S 1 #9x1 TRU-GRIP SCREW ON PEAK SIDE AND (1) #9x1"TRU-GRIP SCREWS (2) #9x1"TRU-GRIP S(::REWS ON EAVE SIDE OF ON PEAK SIDE AND (2) ON PURLIN IN HOLES SHOWN (JOINT MUST BE TIGHT BEFORE FASTENING��:;LIPS EAVE SIDE IN HOLES SHOWN. � � ,.: (JOINT MUST BE TIGHT BEFORE OI< FASTENING CLIPS) 2x4 TRUSS TIE DETAIL � ° (ne'`I= 2x4� BUTTED PURLIN DETAIL ` L 1 d �— o [ Z o U c d #8x3 1/2"WOOD SCREWS Q 1W O.C. FASTENED THROUGH THE ALUMINUM DOOR SIDE JAMBS #8 x 3 1/2"WOOD SCREWS SPACED r � INTO THE 2x4 ROUGH FRAMING. PRE-DRILL HOLES IN ALUMINUM DOOR JAMB TO AS SHOWN ABOVE TO AVOID DOOR J.J a ACCEPT WOOD SCREWS. SCREWS ARE NOT REQUIRED IN THE HEAD OR THE SILL. INSTALLATION SCREWS C.005 Z HEAD FLASHING �— 7/16"OSB PANEL 1 1 1 r DLIJ OOR JAMB 2"x4"ROUGH FRAMING .� WALK DOOR JAMB DETAIL DRAWN BY.' B. HAYES DATE: 7/20/2006 CHECKED BY.' J.SMITH NOTE: DATE: 8/21/2006 DOOR PANEL AND WINDOW PROTECTION DETAILS ARE FOR INSTALLATION REVISED GATE INSTRUCTIONS ONLY, AND ARE NOT HEAD FLASHING PROVIDED OR INSTALLED BY MORTON 7/16"OSB PANEL REVISED DATE.' BUILDINGS' INC.OR MORTON BUILDINGS' DOOR SLAB REVISED DATE SUBCONTRACTORS AND ARE THE OWNERS REVISED DATE.' RESPONSIBILITY. •'' bl` N5c'���'i OSB PANEL IS 1"WIDER THAN THE WIDTH OF THE DOOR • 'L. ' . ON FROM OUTSIDE OF TRIM TO OUTSIDE OF TRIM * • ��' sE',�' .Q �• 0. WINDBOURNE DEBRIS PROTECTION - WALK DOOR WALK DOOR SECTION not 0� • zl . a SCALE.•AS NOTED SHEET NO. S OF S 9 .00 OFFICE.' CUTCHOGUE, N.Y. JOB NO. 128-0788 U A 10 � w m O :E D 3.0'WIDE Z Lu 3'-0"WIDE (ZONES 2&3) � o ZONE 2 (ZONE 2 &3) _ 3-0' WIDE ( ) FL�] (ZONE 2 &3) d (ZONE 1) (ZONE 3) \' VENT-A-RIDGE 2 3.0'WIDE 12 T#16 GABLE TRIM (ZONE 2) (ZONE 2&3) 4 (ZONE 3) "'� �• 1 1 1 Lu S'O.G.GUTTERS c HI-RIB STEEL HI-RIB STEEL T#21 CORNER TRIMLjj b T#21 CORNER TRIM Ills � ;:���'' 1� a,. Z T#167 TRANSITION TRIM T#167 TRANSITION TRIM HI-RIB STEEL WAINSCOT HI-RIB STEEL WAINSCOT T#21 CORNER TRIM T#21 CORNER TRIM O T#167 BASE TRIM T#167 BASE TRIM ° 39'-0"WIDE (ZONE 4) '1 f - —,,.� �r E 2d.0'WIDE (ZONE 4) 3'-0"WIDE 3'-0°WID �• ,— 3.n'WIDE � � 3.0 wIDE (ZONE 5) (ZONE 5) 4 6 (ZONE 5) (ZONE 5) I-JLJ 37'-U' I 8'-0' all / 6E 22'-0 1/T ! 7'-11 1/2" p S' 4E 2 0 C7 EAST ELEVATION Nt , � ca ,� 5 NORTH ELEVATION O ' 2 . 3'-0U'WIDE 1 V 1 f RJ (ZONES 2&3) 3'-0"WIDE (ZONE 2) (ZONE 2 &3) Rfferer�oe � ZONE 2 &3 Comer ( ) � (ZONE 1) (ZONE 3) —� } VENT-A-RIDGE3.01 2 a (ZONE 2) , (ZONE 2& ) dI� 1�- — T1T 16 GABLE TRIM L_u (ZONE 3) 5'O.G.GUTTERS HI-RIB STEEL WI-RIB STEEL T421 CORNER TRIM T#21 CORNER TRIM DRAWN BY.' B. HAYES � T#167 TRANSITION TRIM7#167 TRANSITION TRIM DATE.' 7/20/2006 HI-RIB STEEL WAINSCOT' HI-RIB STEEL WAINSCOT T#21 CORNER TRIM T#21 CORNER TRIM CHECKED BY.' J.SMITH T#167 BASE TRIM T#167 BASE TRIM DATE.' 8/21/2006 ---►i 1 i -- —„.� � 1 f -- RE VISE D DATE' 3-CYWIDE 39'-U WIDE (ZONE� 30WIDE) 24.0"WIDE (ZONE d) 3.0'WIDE REVISED DATE.' _1 (ZONE 5) (ZONE 5) 3.0 WIDE (ZONE 5) (ZONE 5) REVISED DATE,' 13'-6" 41'y6° SOUTH ELEVATION EVISED DATE' a in WEST ELEVATION 2' 8' * ,0 �. SCALE: •t� a O 1' d' } NOTE: pj�� �InN11/1 DOOR AND WINDOW LOCAT'1IONS ARE TAKEN �� , �3 . a to FROM THE EXTERIOR FACE OF THE HAILERS AND ARE00 TO THE CENTER OF THE DOOR AND WINDOW UNITS. mom VERIFY' ALL LOCATIONS WITH THE OWNER. (—SCALE.-AS NOTED - _ . SHEET NO. S4 OF S9 .00 OFFICE: CUTCHOGUE, N.Y. JOB NO. 128-0788 GABLE PURLIN FLASHING FF 2000 HI-RIB STEEL T#16 GABLE TRIM 2x4 PURLINS @ 23"O.C. 9 (4) 0.135"x 2 1/4" R.W. NAILS OR 16d R.S. NAILS ^----�-- (NO. 2 SPF) 2x6 FASCIA —\ ® TRUSS IN COLUMN SADDLE FF 2000 HI-RIB STEEL T#194 TRIM USP RT4 I IURRICANE �— (1) 20d R.S. NAIL THROUGH STRAP cj io LAMINATED COLUMN 2x4 PURLINS @ 23" O.C. SOFFIT ANCHOR 16 & INTO BRACE 10 N 2' END BRACE STRAP W/ PRE-PUNCHED o, �s (NO. 2 SPF) HOLES (BEND TO FIT) FASTENED W/ o HI-RIB/SOFFIT CAP TRIM .�� i � 2x4 BEV. PURLIN 12 (3) 0.140 x 1 1/2" R.S. NAILS �. w WIRE MESH 4 14 30' END TRUSS 2x6 DIAGONAL BRACING FASTENED � m FILLER STRIP i s :D USP RT4 HURRICANE ANCHOR 2-2x6 E.C.E. i TO COLUMN W/(4) l6d R.S. NAILS Z 2x6 BEV. FASCIA --- ,- c o ON ALL PURLINS 6 30 2090' S.C. -TRUSS Z 5" O.G. GUTTERS ---- KYNAR HI-RIB STEEL 0 T#144 & 146 FASCIA TRIM 30' 2090 S.C. TRUSS 1s19 SOFFIT ADDL. 2x6NAILER - - - - - - - - - - - - - - - - - - '*� HI-RIB/SOFFIT CAP (2) 1/2"x5 1/2" M. BOLTS & ® � O (4) 20d R.S. NAILS 2.x4 TRUSS TIE 2x6 OVERHANG NAILER 1171-010 LLJ cl� KYNAR HI-RIB STEEL D Lu 1=I 3-2x6 LAMINATED COLUMN }: 1 1/4"xl 1/4"xl 4 GA. SUPPORT ANGLE ' Z _ FASTENED TO COLUMN AT EACH �..J D (6) ROWS 2x4 NAILERS \ CORNER WITH (3) .148"0 x 2" 0 -- �\ STAINLESS NAILS. (12 TOTAL NAILS 3-2x6 LAMINATED COLUMN (2100 MSR @ 22" O.C.) `� PER COLUMN) O cl_ 14 GA. CHANNEL WITH 1/4" PLATED (5) ROWS 2x4 NAILERS RIVET TO SUPPORT ANGLE (2100 MSR @ 22" O.C.) @ �--- 14'-0" UNDISTURBED SOIL � ;o GRADE TO HEEL STILT NOTES Il-- o 1. INSTALL PRESSURE TREATED c4l -- 0 2x2 VERTICAL BLOCKING LOWER COLUMN WITI-i STILT IN AT COLUMN LOCATION NOTE: THE AUGURED HOLE. o .o THIS :SECTION IS THE SAME AS 2, POUR MINIMUM THICKNESS OF — y SECTfION "A" EXCEPT FOR READI-MIX CONCRETE INTO THE O 0 T#167 TRANSITION TRIM THE IITEMS AS NOTED. ° HOLE AS SPECIFIED. �/ Jca 2x6 NOTCHED NAILER 11 3. BACKFILL AND COMPACT THE KYNAR HI-RIB STEEL WAINSCOT ANNULAR SPACE AROUND THE 5/4 BLOCK STILT ISOMETRIC COLUMN TO GRADE WITH SOIL Z 7/16" OSB PROTECTIVE LINER @ AUGURED FROM THE SITE. i l l s T#167 BASE TRIM W/L-CAP TRIM PROTECTOR C w (1) ROW 2x8 TREATED SPLASHBOARD to V5 18" LOWEST l _J 1 g MEMBER CUT-OFF �— 4" CONCRETE FLOOR* r ;...=. . 18" LOWEST ----� FINISH 5" MEMBER CUT-OFF GRADE 4" MINIMUM COMPACTED GRANULAR BASE � d- ;;,°- - • . - "' A a CONCRETE FLOOR NOTES < 1.)3500 PSI,5 1/2 BAG MIX CONCRETE. '• - 2.)REINFORCING:6x6-10x10 WWM. °- a a 3.)SLOPE GRADE AWAY FROM BUILDING @ 1"PER FINISH GRADE 4'-0" FOOT FOR A MINIMUM DISTANCE OF 10'PLUS OVERHANG WIDTH. DRAWN BY: B. HAYES ° a - 4.)WHEN A VAPOR RETARDER IS PROVIDED,PLACE A ° MINIMUM 6 MIL POLYETHYLENE VAPOR RETARDER ON Si\ DATE: 7/20/2006 A '''� a 'd AOP OF A MINIMUM 4"N DIRECTLY BELOW THE CONCRETE FLOOR.GRANULAR BASE 4'-0" CHECKED BY., J. SMITH 224M (14 GA.) COLUMN STILT s'\ 3-2x6 LAMINATED DATE: 8/21/2006 10"THICK MINIMUM READI-MIX CONCRETE BELOW s�� COLUMN REVISED DATE. BOTTOM OF LOWER COLUMN WITH ADDITIONAL 218M (14 GA.) COLUMN STILT 22 NAILS READI-MIX BACKFILLED TO 4' BELOW GRADE. .A' a 18 NAILS REVISED DATE., PLACE CONCRETE BELOW AND ABOVE BOTTOM O � °• 8" THICK MINIMUM READI-MIX CONCRETE s,� 40 1 NAILS TOTAL 24"O LOWER COLUMN IN ONE OPERATION. BELOW BOTTOM OF LOWER COLUMN WITH r. 2 j7 REVISED DATE: ADDITIONAL READI-MIX TO TOP OF 218M STILT (9"+). • • REVISED DATE: 16"O PLACE CONCRETE BELOW AND ABOVE BOTTOM OF o�Es '0 LOWER COLUMN IN ONE OPERATION. : ENDWALL SECTION B INTERIOR wu* SCALE: 1/2"= F-0" 46 NOTE: EXTERIOR FOOTINGS ARE DESIGNED FOR A NAIL KEY 111 ` �o 11'1 2000 PSF SOIL BEARING CAPACITY. NOTE: ® 0.148"x 4" (20d) NAILS ) LOCAL CONDITIONS MAY REQUIRE ♦ IDENTIFIES ITEMS THAT ARE NOT PROVIDED • 0.131"x 3-3/4" (20d) SMOOTH SHANK GUN NAILS MODIFICATIONS. SIDEWALL SECTION A BY MORTON BUILDINGS, INC. OR MORTON 08 , ` SCALE: 1/2" = F-0" BUILDINGS' SUBCONTRACTORS AND ARE THE COLUMN SPLICE FASTENING DETAIL OWNER'S RESPONSIBILITY. SCALE: 1/2"= V-0" —SCALE:AS NOTED SHEET NO. S5 OF S9 OFFICE: CUTCHOGUE, N.Y. JOB 2 NO. 128-0788 12 (2) 60d R.S. NAILS IN 6„ , 3" 4 1 — OVERHANG RAFTER 2x6 UPRIGHT , C13 2x4 PURLIN CUT TO FIT BETWEEN OVERHANG FRAMES 9"MESH KYNAR HI-RIB STEEL CL_ cv 0 2x10 TRACK GIRT D Z ALIGN 50M BASE ANGLE WITH EDGE OF (3) 2x12 BEAM 11 T#71 TRACK COVER Z &BOLT THROUGH COLUMN &TRUSS WITH(]) 1/2' 1/2' 30'2090 S.C.TRUSS 51 M TRACK ( O M. BOLT (1/7' FLAT WASHER ON BACK SIDE ONLY). 3x4 TRACK BLOCK n 14'-0" a. NO FASTENERS ARE REQUIRED DOWN INTO BEAM TO GRADE 1 1/2'x2"BLOCK&T#74 T#71 TRACK COVER 200L TRUSS HANGER W/(8) 1 1/2" R.S. NAILS T#23 JAMB TRIM 51 M TRACK 3x4 TRACK BOARD FASTEN BOTTOM OF TRUSS HEEL &BEAM W/ (1) 1/2"xl2" Lu 1 1/2"'x2" BLOCK LAG BOLT I I" BELOW M. BOLT &2 1/4" IN FROM EDGE (BEYOND) JAMB COLUMN n 1 l 2x3 JAMB (BEYOND; (BEYOND} �-G. 1 u GRADE TO BOTTOM T#74 TRACKBOARD TRIM OF COLUMN (CENTERED ON 3-MEMBER BEAM). BOTTOM 2'TREATED) OF TRACK GIRT T#25 JAMB TRIM (3) 2x12 HEADERS (NO. 1 SYP) ca W 2x12 TRACK GIRT (NO. I SYP) SLIDING DOOR HEADER SECTION D 2x3 JAMB (BB' ON9; _ 3.2x6 I.A►MINATI50 JAMB COLUMN 3CALB3 1"� "� ]�! I�TR,. BOTTOM 2'TRl!ATED) BEYOND W/AN ADDITIONAL 2x6 TREATED LAMINATE FOR HEADER I 'L"j SUPPORT SLIDING DOOR HEADER SECTION C o SCALE: 1"= 1'-0" OwLA-1 z J ]2" F'"— O MEMBER-`�� R EMBER #2 '""` � - MEMBER #3 3" 6„ [3" cacole 0- p x NAIL PATTERN PLAN VIEW STEP 2:ATTACH MEMBER #3 WITH 20d GUN I l l i NAILS Q 6"O.C. AT TOP AND BOTTOM `off OF BEAM, SET NAILS 2"FROM TOP a. AND BOTTOM OF BEAM, ATTACH MEMBER #3 WITH 2OdrGUN � (3) 2x1 BEAM • FASTEN HEADER TO COLUMN � g NAILS @ 6"O.C.AT TOP AND BOTTOM STEP 1: WITH ( ) 20d R.S. NAILS W-� OF BEAM. SET NAILS 2' FROM TOP ATTACH MEMBER #1 TO MEMBER #2 WITH AND BOTTOM OF BEAM. 1 Od R.S. GUN NAILS Q 12"O.C.AT TOP 6" (3) 2x1 BEAM FASTEN HEADER TO COLUMN AND BOTTOM OF BEAM. SET NAILS Z' 3-2x6 LAMINATED COLUMN STEP I' — WITH ( ) 20d R.S. NAILS FROM TOP AND BOTTOM OF THE MEMBERS. ATTACH MEMBER 41 TO MEMBER 1 �� #2 WITH 1 Od R.S.GUN NAILS« B. HAYES 6" ' • 12'O.C.AT TOP AND BOTTOM 3-2x6 LAMINATED COLUMN DRAWN BY. DATE; 7/20/2006 OF BEAM. SET NAILS 2'FROM TOP AND BOTTOM OF THE MEMBERS. �.' ' • 1 1-a1 Cl-IECKED BY' J.SMITH DATE: 8/21/2006 REVISED DATE.' 2X6 TREATED ADDITIONAL LAMINAT9 FOR HEADER SUPPORT. FASTEN TO COLUMN WITH 20d GUN NAILS 2X6 TREATED FACEBOARD FOR HEADER SUPPORT. 2x6 TREATED ADDITIONAL LAMINATE FOR HEADER LRE SED DATE' @ 6"O.C. IN 1 1/2"IN FROM EACH EDGE, FASTEN TO COLUMN WITH 20d GUN NAILS SUPPORT. FASTEN TO COLUMN WITH 20d GUN SED DATE,' @ 6"O.C. IN 1 1/2"IN FROM EACH EDGE. NAILS @ 6" O.C. IN 1 1/2"IN FROM EACH EDGE. SED DATE s NAILING FOR 3 2x7 2 BEAM HEADERS NAILING FOR (3) 2xl 2 BEAM HEADERS . ,,� L s • . . {BEAM BUTTS TO SIDE OF COLUMN} (BEAM BUTTS TO FACE OF COLUMN) 4A * ©t� � l. (-SCALE.•AS NOTED SHEET NO. S 6 OF S 70 OFFICE: CUTCHOGUE, N.Y. IIII DOUBLE TOP"D"RAIL IIII JOB NO. 128 0788 KYNAR HI-RIB STEEL I (16 GUAGE) 60' END TRUSS 14'-3-2x6 LAMINATED �`I I c i TRACK GIRTT#71 TRACK COVER 2-2x6 UPRIGHT JAMB COLUMN I I °` TO GRADE 51 M TRACK (BEYOND) I STRUT I N y , 3x4 TRACK BOARD HORIZONTAL"I"S.S. RAIL VERTICAL"I"RAIL TOP"D"RAIL (16 GUAGE) I (0.06"WEB, 0.13"FLANGE) �--• 1 1/7'x7' BLOCK I ��� I (0.09"WEB, 0.15"FLANGE) TRACK GIRT T#74 TRIM i TO GRADE I I O z Lu T#23 JAMB TRIM I I I Z O CL HORIZONTAL"I" I Q LATCH HANDLE I I INTERMEDIATE RAIL 47E A/S LATCH STRIKE PLATE I I (0.06"WEB, 0.13"FLANGE) I I w = Q W 2x3 JAMB 3-2x6 LAMINATED JAMB COLUMN I ICQ W/2x6x7'TREATED SPLICE STIFFENER I VERTICAL"I"RAIL I (0.09"WEB, 0.15"FLANGE) I I z LATCH HANDLE I o SLIDING DOOR HEADER SECTION I i x SCALE: 1"= 1'-0" I I o I ;. CENTER DOOR GUIDE I �,�( DOUBLE BOTTOM"D"RAIL 0 I ` L 1 1 (16 GUAGE) o I I GRADE `= 0 7'-4 1/2" 7'-4 1/2' o 14'-9" X m O SINGLE SLIDING DOOR FRAME C.� 0 O (TWIN PANEL) I I Y a. C NfER DOOR GUIDE vi 3-2x6 LAMINATED l l M JAMB COLUMN .......� WF 1264 8"'HOOK INSTRUCTIONS DRAWN BY.' B. HAYES VERTICAL'T'RAIL --� 1.SCREW NUT ONTO HOOK. DATE.' 7/20/2006 2.SCREW HOOK INTO LATCH BODY. DOOR GUIDE DETAIL CHECKED BY.' J.SMITH LATCH HANDLE —� DATE.• 8/21/2006 47E A/S LATCH STRIKE PLATE REVISED DATE: REVISED DATE.' HORIZONTAL INTERMEDIATE"I"RAILS 3/$"JAM NUT � REVISED DATE: NOTES: EVISED DATE.' 1.) VERIFY IF DOOR IS SINGLE OR TWIN PANEL y��lA19W9w� ON ALUMASTEEL DOOR REQUEST SHEET. 2.) CHANGE HEIGHT AND WIDTH OF SLIDING DOOR )- ° ON ELEVATION AND SECTION. (DRAW DOOR TO SCALE) �'��. �Q L,. SG,,, 1265 JAMB LATCH BODY 12 x12 SINGLE SLIDING DOOR OUTLINE SHOWN. �} 3.) DETERMINE # OF INTERMEDIATE RAILS, w d RO, f� JAMB DETAIL S.S. RAILS (STRUT RAILS), RAIL THICKNESS, & STRUTS FROM CHECKLIST&CHART. (SEE ALSO CPM PAGE 20-27) l �` 4.) CHECK SECTION FOR ACCURACY TO YOUR SITUATION. LATCH IH A N D L E III v� s��sr�rin��► `.. NOTE: � � • �� ` ��q * IDENTIFIES ITEMS THAT ARE NOT PROVIDED BY MORTON BUILDINGS, INC. RAIL THICKNESS CHART OR MORTON BUILDINGS'SUBCONTRACTORS STANDARD HEAVY AND ARE THE OWNERS RESPONSIBILITY. VERTICAL I HORIZONTAL VERTICAL HORIZONTAL SCALE.•AS NOTED FLANGEWEB FLA GE WEB LA GE EB FLA G _. .07 .Mr' .0 0" .080" 090 1 0 .130 SHEET NO. S7 OF S9 OFFICE.' CUTCHOGUE, N.Y. JOB NO, 128-0788 10 w m o z w Z a LJLJ L:L LOWER CHORD OF cl�-I 1 � 1 7116"OSB END TRUSS ��+�.1 STD, 2x4 BUILDING NAILERS 'I- - - - - - - - - - - - - - - - - - _'_ . _ _'- - _ _'- - - _'- - - -'_ 2x6 VERTICAL BLOCKS @ z COLUMN BETWEEN NAILERS 2x6 BLOCK BETWEEN NAILERS NAILED TO COLUMN W/20d 0 — = u GUN NAILS. NAILED 3"O.C. — O '` _ _ _ _ _ _ PERIMETEIR OF OSB SHEETS EXTRA NAILERS ADDED — NAILED WI/1-3/4"SHINGLE BETWEEN STD. NAILERS — — — — — — — — — — — — — — — — — — GUN NAILS SPACED 3"O.C. (MAX.SPACE TO BE 24") z LAMINATED COLUMN- - - - - - ` - - - - - - - _ - - - ��,.�.+, OSB NAILIED 1'0 INTERMEDIATE Q SUPPORT5 W/1-:3/4'SHINGLE o GUN NAILLS SPACED 6"O.C. — — — — — — — — — — — — — — - — O 2x4 NAILERS n _ — LAMINATED COLUMN 7/1 b" OSB ----• Oe — _ _ — — _ — — _ — — — — — — — — — LAMINATED COLUMN ) LM_ 1 i Q SI3 SH ARWALL DETAIL w - - - — — — — — — — — — — — — — 5/4x6NAlILER L 1 1 8 (IF PROTECTIVE LINER IS INCLUDED) 1 — — — — — — — — — — — — — — — — — - - - - - - - - - - - - - - - - 2x8 TREATED BASEBOARD DRAWN BY.' B. HAYES DATE: 7/20/2006 CHECKED BY.' J.SMITH DATE: 8/21/2006 REVISED DATE' 0S13 SHEARWALL ELEVATION REVISED DATE,' SCALE: 1/2"= V-0„ REVISED DATE' LEVISED �;�aMa�aara:a4 5 .�J SCALE:AS NOTED SHEET NO. S8 a, S9 OFFICE: CUTCHOGUE, N.Y. JOB NO. 128-0788 40 �.... w cv w on z Z w Z O LLJ W m ROOF STRUCTURE FASTENING SCHEDULE ., O VENT-A-RIDGE TO RIDGE BASE TRIM #9 x 1"STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS Q 8"o.c. RIDGE BASE TRIM TO 2x4 PURLINS #9 x 2"STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS AT EVERY HI-RIB (1,-0"o.c.) ci ? Y! " �} HI-RIB STEEL TO 2x4 PURLINS #9 x 2"STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS AT EVERY HI-RIB (1 -(7 o.c.) ''^�► a 20 ga. GALVANIZED PURLIN CONNECTORS #9 x 1"TRU-GRIP SCREWS •C" � � O ;. 5 2x4 PURLINS TO TRUSS, 0.200"x 6" (60d) RING SHANK NAILS IN PRE-DRILLED HOLE � e RT4 HURRICANE ANCHOR TO 2x4 PURLINS (4) 0.135 (8d) x 1-1/2" RING SHANK NAILS F----- _ RT4 HURRICANE ANCHOR TO TRUSS (4) 0.135 (8d) x 1-1/2" RING SHANK NAILS �O (2) 1/2k5 1/2"MACHINE BOLTS 30 STRAIGHT C a ' CHORD TRUSS TO COLUMN O 4 0.177 x 4„ (20d) RING SHANK NAILS 1 1 1 o 1 WALL FW �1 ING FASTENING SCHEDULE LQ c X vU COLUMN STILT (14 GA.) TO COLUMN (12) 0.148"x 2" (6d) STAINLESS STEEL RING SHANK NAILS r O Q 2x8 SPLASHBOARD TO COLUMN (4) 0.177'x 4" (20d) STAINLESS STEEL RING SHANK NAILS C SPLICE/ (3) 0.177"x 4" (20d) RING SHANK NAILS Q STANDARD CONNECTION p i 2x6 NOTCHED NAILER TO COLUMN (4) 0.148"x 3-1/2" (16d) NAILS @ SPLICE/ (3) 0.148"x 3-1)/ir' (16d) NAILS Q STANDARD CONNECTION a' Q 7/16" OSB TO SPLASHBOARD &NOTCHED NAILER 0.099"x 1-1/4"ASBESTOS SIDING NAILS 2x4 NAILER TO COLUMN (4) 0.148"x 3-1/2" (16d) RING SHANK NAILS @ SPLICE/ (3) 0.148"x 3-1/7' (16d) RING SHANK NAILS Q STANDARD CONNECTION LL J M I i (�+ END TRUSS TO 2-2x6 END COLUMN EXTENSIONS (6) 0.177'x 4" (20d) RING SHANK NAILS w 2x4 PURLIN TO END TRUSS 0.200"x 6" (60d) RING SHANK NAILS IN PRE-DRILLED HOLE i��^—� e RT4 HURRICANE ANCHOR TO END TRUSS (4) 0.135" (8d) x 1-1/2" RING SHANK NAILS RUBBERWASHER PANHEAD INTERNAL DRIVE SCREWS AT EVERY HI-RIB �' g d HI-RIB STEEL TO NAILERS #9 x 2"STAINLESS STEEL 1 SOFFIT TO WALL INSERTED IN PRE-FORMED SLOT IN SOFFIT/HI-RIB CAP ..�...r1 SOFFIT TO FASCIA T-50 MCONEL STAPLES (2) PER PIECE o 7/16"OSB SHEARWALL - OSB TO PERIMETER BLOCKS/FRAMING 0.120"x 1-3/4"SMOOTH SHANK SHINGLE GUN NAILS Q 3"o.c. i OSB TO INTERMEDIATE FRAMING 0.120"x 1-3/4"SMOOTH SHANK SHINGLE GUN NAILS Q 6"o.c. ® BLOCKS t0 COLUMNS 0.131x 3-3/4' (20d) SMOOTH SHANK GUN NAILS Q 3"o,.c. frD RAWN BY.' B. HAYES ATE.' 7/20/2006 HECKED BY.' J.SMITH DATE: 8/21/2006 REVISED DATE: REVISED DATE.' REVISED DATE.' LEVISED DATE' r ��uiiiAA9Gl;) c� o Ito _� . �3 (_SCALE,•AS NOTED SHEET NO. S9 OF S9