Loading...
HomeMy WebLinkAbout33042-Z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-33099 Date: 06/16/08 THIS CERTIFIES that the building NEW DWELLING Location of Property: 925 WILLOW TERRACE LA ORIENT (HOUSE NO.) (STREET) (HAMLET) County Tax Map No. 473889 Section 26 Block 2 Lot 31 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated MAY 9, 2007 pursuant to which Building Permit No. 33042-Z dated MAY 17, 2007 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ONE FAMILY DWELLING WITH FIRST AND SECOND FLOOR COVERED PORCHES, REAR DECKS AND ATTACHED TWO CAR GARAGE AS APPLIED FOR. The certificate is issued to JOSEPH G MANZI, JR TRUST (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL R10-05-0202 04/29/08 ELECTRICAL CERTIFICATE NO. 3049765 05/30/08 PLUMBERS CERTIFICATION DATED 06/12/08 CHARLES SANDERS i //A ho zed gnature Rev. 1/81 Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL l� Q 765-1802 I �ti �•.-`_ -- APPLICATION FOR CERTIFICATE OF OCCUP NC t 6 ' This application must be filled in by typewriter or ink and submitted to the Building Department wiithlthe"fol ovc��l A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$25.00,Additions to dwelling$25.00, Alterations to dwelling$25.00, Swinuning pool $25.00, Accessory building$25.00, Additions to accessory building$25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00, Commercial$15.00 Date. 7�IG`6 New Construction: z Old or Pre-existing Building: (check one) Location of Property: %2, W/L,Low Tv tZRAL p feI t_,v z House No. Street Hamlet Owner or Owners of Property: �Vu�-j P&I L -t/T Suffolk County Tax Map No 1000, Section Block 2— Lot Subdivision Filed Map. Lot: Permit No. .30 Z Date of Permit. Applicant: & ( ,¢� Cn/! Health Dept. Approval: 10 6)- 020 'L Underwriters Approval: ,N`/ 13o4a iv of E!/I- 0,Yd_1aWn e I GAS Planning Board Approval: �Pp 3b'f76�� 3 Request for: Temporary Certificate Final Certificate: r/ (check one) Fee Submitted: $ �3 D�. L �'� �`� ` Opplicant Signature FEB 03 '04 11:00RM SOUTHOLD BUILDING 631 765 9502 � 3 3 6Lt2 P. 1 sUFFO4 3 "Own Hall,S3095 Main Road ►� Fax(631)765-9502 P.O. Box 1179 Tclaphone(631) 765-1802 Southold,'4ew York 1 1971-0959 BUILDING DEPARTMENT TOWN OF ISOUTHOLD CERTIFICATION Date: Building Permit No, 3 0 2 Owner: '�� ��Urr<o v 6y �c w��lC;a� -� La f r (Please print) Plumber. (Please print) j i 1 I certify that the solder used in the water supply system contains less than 2/10 of 1% ICad. (Plumbers Signature) Sworn to before me this oZ � \ day of�0 Y) Q 2009 DORIS DAYTON NOTARY PUBLIC,State of New York No.4753763 u.� Qualified in Suffolk County Notary Public —County Commlgglgn Expires /a7:77= C.I�GI�CJCI�LICI�CPCP[.I�LI�[.I 10 THIS CERTIFICATE OF COMPLIANCE THE BOARD OF FIRE UNDERWRITERS 5 S 5 5 BUREAU OF ELECTRICITY e5 40 FULTON STREET — NEW YORK, NY 10038 5 5 5 5 CERTIFIES THAT 5 5 5 5 Upon the application of upon premises owned byAFTON 5 5 5 5 2 BENTNOR STRECAL ET P.O. INC OC BOX 702KHALL EVELOPMENT CORP. P c5 5 MASTIC, NY 11950, ROCKY POINT, NY 11778 5 5 S 5 Located at 925 WILLOW TERR. LANE ORIENT, NY 11957 5 5 r5 5 Application Number: 3049765 Certificate Number: 3049766 5 5 5 SSection: 26 Block: 2 Lot: 31 Building Permit: 33042Z BDC: ns11 5 S5 Residential 5 Described as a occupancy, wherein the premises electrical system consisting of 5 electrical devices and wiring, described below, located in/on the premises at: C5 5 Basement,First Floor, Second Floor, Outside,Attic, 5 5 5 5 5 A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed Cj 5 herein, was conducted in accordance with the requirements of the applicable code and/or standard 5 promulgated by the State of New York, Department of State Code Enforcement and Administration, or other 5 authority having jurisdiction, and found to be in compliance therewith on the 30th Day of May, 2008. C5 5 Name QTY Rate R@AU Circuits Tyne 5 5 Alarm and emergency equipment 5 Sensor 2 0 0 Carbon Monoxide 5 SSensor 6 .0 0 Smoke S 5 Appliances and Accessories 5 5 Air Conditioner. 1 0 Above 1500 BTU 5 5 Exhaust Fan 3 0 F.H.P 5 5 Furnace 1 0 Oil 5 5 Future Appliance Feeder 1 0 20 Amps 5 5 5 Hydro Massage Tub(Therapeutic) 2 0 5 Pump Motor 1 0 1 H.P 5 S Service c5 5 Service Disconnect: 0 200 cb 5 5 ServicelPhase3wService Rating200Amperes 5 5 Wiring And Devices 5 5 Dimmer 34 0 120 V 5 Fixture 2 0 High Intensity 5 Fixture 2 0 Low Wage 5 Fixture 4 0 Flouresent 5 5 Continued on Next Page 1 of 2 5 5 5 5 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. S S 5 0 cP�PCPcnCn�PrJ�CPCnC 0P�PC1ff PCnCP�r1P�PCPc ncP�nCPCPcPcPCnCnCP�P�PcPCnt_PcPCnCPcPcPCP11nCrc.rCPCPLrL3r PCri:3Mi rCPcPcPCPcPcPcPCPCn 0 a77NEW =YORKBOARD ATE OF COMPLIANCE THEOF FIRE UNDERWRITERS 5 5 BUREAU OF ELECTRICITY 5 rSj 40 FULTON STREET — NEW YORK, NY 10038 5 5 5 CERTIFIES THAT 5 5 5 5 Upon the application of upon premises owned by C5 5 5 AFTON ELECTRICAL CONT, INC ROCKHALL DEVELOPMENT CORP. c5 2 BENTNOR STREET P.O. BOX 702 5 5 MASTIC, NY 11950, ROCKY POINT, NY 11778 5 S 5 5 Located at 925 WILLOW TERR. LANE ORIENT, NY 11957 c5 5 5 5 Application Number. 3049765 Certificate Number: 3049765 5 5 5 Section: 26 Block: 2 Lot: 31 Building Permit: 33042Z BDC: ns11 5 5 Residential �u Described as a occupancy, wherein the premises electrical system consisting of 5 5 electrical devices and wiring, described below, located in/on the premises at: 5 5 Basement, First Floor, Second Floor, Outside,Attic, 5 5 e5 5 A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed 5 5 herein, was conducted in accordance with the requirements of the applicable code and/or standard 5 5 promulgated by the State of New York, Department of State Code Enforcement and Administration, ,or other 51 5 authority having jurisdiction, and found to be in compliance therewith on the 30th Day of May, 2008. 5 5 Name QTY Rate Rating Circuits ITY Ne 5 5 Fixture 84 0 Incandescent 5 5 Cj Outlet 92 0 Fixture 5 Outlet 122 0 Gen, Purpose 5 5 Receptacle 1 0 20a 5 5 Appliance 5 5 Receptacle 1 0 3a0 Dryer 5 5 5 Receptacle 8 0 GFCI Receptacle 71 0 Gen, Purpose 5 5 Switch 41 0 Gen, Purpose 5 5 5 5 5 5 5 5 M 5 5 5 c5 5 seal 5 5 S 2 of 2 5 5 5 5 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated, rj 5 5 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 33042 Z Date MAY 17, 2007 Permission is hereby granted to : WALTER & WF REICHEL 449 . 1/2 HENRY ST BROOKLYN HTS,NY 11231 for CONSTRUCTION OF A NEW SINGLE FAMILY DWELLING AS APPLIED FOR at premises located at 925 WILLOW TERRACE LA ORIENT County Tax Map No. 473889 Section 026 Block 0002 Lot No. 031 pursuant to application dated MAY 9, 2007 and approved by the Building Inspector to expire on NOVEMBER 17, 2008 . Fee $ 1, 705 . 60 Auth zed Signa ure ORIGINAL Rev. 5/8/02 soaryo TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ --FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS- 1 j Looll DATE INSPECTOR /1000 oF soaryO� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ IF ATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT NSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: DATE INSPECTOR \oF soulyo�o TOWN OF SOUTHOLD BUILDING DEPT. - e-� 765-1802 INSPECTION [ ] FOUNDATION 1ST ROUGH PLOG. [ ] FOUNDATION 2ND [ ] INSULATION FRAMING STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION R M KS: U� - - e DATE �^ INSPECTOR pp� 61— • OF SOUT�olo ��y00UNT`1,0c� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTto- N [ ] FOUNDATION 1ST [UGH PL13G. [ ]tNDATION 2ND [ ] INSULATION ING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESTS T CONSTRUCTION [ ] FIRE RESISTANT PENETRATION r � - REMARK �- e, DATE INSPECTOR �� i souryo�o courm TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] PLBG. [ ] FOUNDATION 2ND [ INSULATION [ ] FRAMING / STRAPPING FI _ [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS:— DATE )m INSPECTOR OF SO�lyo eoUNr+,��' TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INS ION [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION E ARKS: c,4.1� ftc 4. c✓� c DATE INSPECTOR soulyolo "ourm,��' TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ' INAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: o � F w DATE 1,13 0G INSPECTOR J EFFREY T. B UTLER',q P. E. 20 OVERHILL RD. SHOREHAM, NEW YORK 1 1 786 63 1 -20B-B850 LICENSED PROFESSIONAL ENGINEER MEMBER NATIONAL SOCIETY OF PROFESSIONAL ENGINEERS January 15, 2008 Town of Southold Building Department Re: Proposed Residence-Orient Permit# 33042Z Dear Sirs: Please note the following concerning this application: • I have inspected the strapping and anchoring pursuant to the building code for the front porch ceiling and floor and find that the work conforms to the plan as filed with this application. Please call if you should have any additional concerns about this application. ®� N�U Sincerely, T.B COD F��y UT�F HZ�tler, E. � w 073493 P�� 90FESS\ - - JAN Z FIELD INSPECTION REPORT DATE I COMMENTS / d U� FOUNDATION(IST) zz ------------------------------------- FOUNDATION(2ND) _ V 171 � o y oa-�cam,,...-•.� v'�-c��� � ROUGH FRAMING& � IVA y PLUMBING r . . INSULATION PER N.Y. STATE ENERGY CODE tooP FINAL S io✓C a>o s . L ADDITI NAL CO NTS O ,1' z rn 01 Ll0000l i t J G y 00 z 0 U" x ' d y TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 3 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 c Survey www. northfork.net/Southold/ PERMIT NO. 33 0 @-'� Check Septic Form N.Y.S.D.E.C. Trustees Examined ,20� Contact: Approved 20 Mail to: Disapproved a/c Phone: y q �� 5 Expiration ,20 Bui spector 7 ` g 20 6 APPLICATION FOR BUILDING PERMIT -- Date 7 , 20 INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans, accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing; the extension-of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name,if a corporation) P•O . 13Ox 702 (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder r7C-,C,-a.I Cry n 7 — c-o r' Name of owner of premises (As on the tax roll or latest deed) If appli t is a o ra ' , signature of duly authkized officer (N e and title o co oratk officer) ` Bui ers License No. Plumbers License No. P I U-,b re c h 3 I L4 9_1M P Electricians License No. Pv C c,, U (f I e c j j c 41 8 06 Other Trade's License No. 1. Location of land on which proposed work will be done: 725 1../u A l6 T-GrrrC-ec, LQ_pn L, oki c, `f' House Number Street Hamlet County Tax Map No. 1000 Section SAG Block ,Z Lot 3 f Subdivision ji419 PW Ter' CZC Filed Map No. V—A 07 Lot (Name) 2. State existing use and occupancy of premises and intended use and pccupancy of proposed construction: a. Existing use and occupancy V C" d b. Intended use and occupancy ,, e �Ce�•, I d O 3. Nature of work(check which applicable): New Building ✓ Addition Alteration Repair Removal Demolition Other Work (Description) 4. Estimated Cost 1 75, 0 O O o 0 0 Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units f Number of dwelling units on each floor If garage, number of cars _2_ 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front - Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front ff& i _Rear J~� Depth 2 9. Height Number of Stories 2- 7,' Rear i I L-I , O O Depth I E3 8 9LI 9. Size of lot: Front � 2 3> p 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES \/ NO Will excess fill be removed from premises? YES NO _/ 14. Names of Owner of premises \A/1-P Re.'che Address4y 4i/z.f-te" i3��s►el, hone No. Name of Architect T-. 3 L -r-1 c ,- Address P68(*e&34 S,�Ohone No 20S=dayO Name of Contractor 12o c.04, I I Dcv. ( ,� __Address PO Eck 702 P P+ Phone No. 74L4 -2 6`55 15 a. Is this property,within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTY OF S�C o�►�) -1-0 s c.-a In 6. M c e)z: being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)He is the C 0►-� - '-Ct GNU r (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me thi da fJIA�t_ 20 0 � otary Public 1-gnature of Appy�an/- FREDERICK J.NAPCLITAN® Notary Public,State of New York Reg.No.01 NA6089519 Qualified in Suffolk County 1 Comralssion Expires March 24, 0-u 1" Dv REScheck Software Version 4.0.1 Compliance Certificate Project Title: Proposed Residence DEC 1 2 Report Date: 12/08/07 Data filename:J:\Manzi\2007—Jobs1070017 rowe dr orient\Orient2.rck Energy Code: New York State Energy Conservation Construction Code Location: Suffolk County,New York Construction Type: Detached 1 or 2 Family Heating Type: Non-Electric Glazing Area Percentage: 16% Heating Degree Days: 5750 Construction Site: Owner/Agent: Designer/Contractor: C/O Willow Terrace Lane Manzi Homes East Jeffrey Butler,P.E.,P.C. and Rowe Lane 631-744-2655 206 Lincoln Street Orient,NY Riverhead,NY Permit Date:4/4/07 631-208-8850 Ceiling 1:Flat Ceiling or Scissor Truss: 1590 30.0 0.0 56 Wall 1:Wood Frame, 16"o.c.: 1836 15.0 0.0 116 Window 1:Vinyl Frame,Double Pane with Low-E: 290 0.340 99 Door 1:Solid: 42 0.220 9 Wall 2:Wood Frame,16"o.c.: 1282 15.0 0.0 84 Window 2:Vinyl Frame,Double Pane with Low-E: 196 0.340 67 Floor 1:All-Wood JoistITruss:Over Unconditioned Space: 1378 30.0 0.0 45 Boiler 2:84 AFUE The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements.When a Registered Design Professional has stan 0 d and signed this page,they are attesting that to the best of c' cationshis/her knowledge,belief,and professional judgment,such plans or are in compliance with this Code. Te4'QCje 'T-- elmet- P.Ei P.C. N� a A C Name-Title/ J a DatEI Project Notes: Revised,converted garage to living space 0 49S 'cr-SSICIA Proposed Residence Page 1 of 4 01, REScheck Software Version 4.0.1 Inspection Checklist Date: 12/08/07 Ceilings: ❑ Ceiling 1:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation Comments: Above-Grade Walls: ❑ Wall 1:Wood Frame, 16"o.c.,R-15.0 cavity insulation Comments: ❑ Wall 2:Wood Frame, 16"o.c.,R-15.0 cavity insulation Comments: Windows: ❑ Window 1:Vinyl Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 2:Vinyl Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door 1:Solid,U-factor:0.220 Comments: Floors: ❑ Floor 1:All-Wood Joist/Truss:Over Unconditioned Space,R-30.0 cavity insulation Comments: Heating and Cooling Equipment: ❑ Boiler 2::84 AFUE or higher Make and Model Number: Air Leakage: ❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed. ❑ Recessed lights are 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,fixtures are installed with a 3"clearance from insulation. Vapor Retarder: ❑ Installed on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: ❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment are identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. ❑ Insulation R-values,glazing U-factors,and heating equipment efficiency are clearly marked on the building plans or specifications. Proposed Residence Page 2 of 4 Insulation is installed according to manufacturer's instructions,in substantial contact with the surface being insulated,and in a manner that achieves the rated R-value without compressing the insulation. Duct Insulation: Supply ducts in unconditioned attics or outside the building are insulated to R-8. Return ducts in unconditioned attics or outside the building are insulated to R-4. ❑ Supply ducts in unconditioned spaces are insulated to R-8. Return ducts in unconditioned spaces(except basements)are insulated to R-2.Insulation is not required on return ducts in basements. Duct Construction: ❑ All joints,seams,and connections are securely fastened with welds,gaskets,mastics(adhesives),mastic-plus-embedded-fabric, or tapes.Tapes and mastics are rated UL 181A or UL 181 B. Exceptions: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). ❑ The HVAC system provides a means for balancing air and water systems. Temperature Controls: Each dwelling unit has at least one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: ❑ Separate electric meters exist for each dwelling unit. Fireplaces: ❑ Fireplaces are installed with tight fitting non-combustible fireplace doors. Fireplaces have a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. Circulating hot water pipes are insulated to the levels in Table 1. Circulating Hot Water Systems: Circulating hot water pipes are insulated to the levels in Table 1. Swimming Pools: ❑ All heated swimming pools have an on/off heater switch and a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps have a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2. Proposed Residence Page 3 of 4 Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" Temperature(°F) 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range ff) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) Proposed Residence Page 4 of 4 EScheck Software Version 4. .1 Compliance Certificate Project Title: Proposed Residence Report Date:05/03/07 Data filename:J:\Manzi\2007—Jobs\ORIENT\Orient2.rck Energy Code: New York State Energy Conservation Construction Code Location: Suffolk County, New York Construction Type: Detached 1 or 2 Family Heating Type: Non-Electric Glazing Area Percentage: 15% Heating Degree Days: 5750 Construction Site: Owner/Agent: Designer/Contractor: C/O Willow Terrace Lane Manzi Homes East Jeffrey Butler,P.E.,P.C. and Rowe Lane 631-744-2655 206 Lincoln Street Orient,NY Riverhead,NY Permit Date:4/4/07 631-208-8850 Ceiling 1: Flat Ceiling or Scissor Truss: 1378 30.0 0.0 48 Wall 1:Wood Frame, 16"o.c.: 1622 15.0 0.0 103 Window 1:Vinyl Frame,Double Pane with Low-E: 243 0.340 83 Door 1:Solid: 42 0.220 9 Wall 2:Wood Frame,16"o.c.: 1282 15.0 0.0 84 Window 2:Vinyl Frame,Double Pane with Low-E: 196 0.340 67 Floor 1:All-Wood Joist/Truss:Over Unconditioned Space: 1378 30.0 0.0 45 Boiler 2:84 AFUE The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans ors ifications are in compliance with this Code. Te f�lj -r t,t+l e.r . P. E. 0 7 Name-Title c OF NE nat re Da e F �1r � r— I W 073493 90FESSI��P Proposed Residence _ Page 1 of 4 w Scheck Software Version 4.0.1 Inspection Checklist Date:05/03/07 Ceilings: ❑ Ceiling 1:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation Comments: Above-Grade Walls: ❑ Wall 1:Wood Frame,16"o.c.,R-15.0 cavity insulation Comments: ❑ Wall 2:Wood Frame, 16"o.c.,R-15.0 cavity insulation Comments: Windows: ❑ Window 1:Vinyl Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 2:Vinyl Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door 1:Solid,U-factor:0.220 Comments: Floors: ❑ Floor 1:All-Wood Joist/Truss:Over Unconditioned Space,R-30.0 cavity insulation Comments: Heating and Cooling Equipment: ❑ Boiler 2::84 AFUE or higher Make and Model Number: Air Leakage: ❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed. ❑ Recessed lights are 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,fixtures are installed with a 3"clearance from insulation. Vapor Retarder: ❑ Installed on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: ❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment are identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. ❑ Insulation R-values,glazing U-factors,and heating equipment efficiency are clearly marked on the building plans or specifications. Proposed Residence � �� �� �� µ Page 2 of 4 Insulation is installed according to manufacturer's instructions,in substantial contact with the surface being insulated,and in a manner that achieves the rated R-value without compressing the insulation. Duct Insulation: Supply ducts in unconditioned attics or outside the building are insulated to R-8. Return ducts in unconditioned attics or outside the building are insulated to R-4. Supply ducts in unconditioned spaces are insulated to R-8. Return ducts in unconditioned spaces(except basements)are insulated to R-2.Insulation is not required on return ducts in basements. Duct Construction: All joints,seams,and connections are securely fastened with welds,gaskets,mastics(adhesives),mastic-plus-embedded-fabric, or tapes.Tapes and mastics are rated UL 181A or UL 181 B. Exceptions: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). The HVAC system provides a means for balancing air and water systems. Temperature Controls: ❑ Each dwelling unit has at least one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: Separate electric meters exist for each dwelling unit. Fireplaces: Fireplaces are installed with tight fitting non-combustible fireplace doors. Fireplaces have a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Circulating hot water pipes are insulated to the levels in Table 1. Circulating Hot Water Systems: Lj Circulating hot water pipes are insulated to the levels in Table 1. Swimming Pools: ❑ All heated swimming pools have an on/off heater switch and a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps have a time clock. Heating and Cooling Piping Insulation: HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2. Proposed Residence _.,......,�... ...�...W._...��_...._.. .m ..w..w,�.._.�_,� Page 3 of 4 Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" Temperature(°F) 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Rangeff) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.6 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) Proposed Residence ��� �� Page 4 of 4 05-22-2007 13:22 SOUTHOLD BUILDING DEPT 16317659502 �33 D�a J2e(CA4PRGE1 Erosion Sedimentation and Storm-water Run-off Control Plan ASSESSMENT FORM Yes No EXEMPTIONS: A. Does this project meet the minimum standards for classification as an Agricultural Project. _ Note: If you answered Yes to any of the above,a Storm-wafer,Grading,Drainage.&Erosion Control Plan is not required. -----------------------_-------------------------------------------- ACTIONS RE UiRING THE SUBMISSION OF A STORM-WATER GRADING DRAINAGE&EROSION CONTROL PLAN CERTIFIED BY A DESIGN PROFESSIONAL IN TIIE STATE OF NEW YORK. Item Number: (A Check Mark (J)for each question is required for complete application) Yes No 1. Will this project retain all Storm-Water Run-off generated on Situ? (This will include all run-off created by site clearing;and/or construction activities as well as all Site improvements and the permanent creation of impervious surfaces.) Zr 2. Will this project require any land filling,grading or excavation where there is a change to the natural existing grade involving more than 200 cubic yards of material within any parcel? 3. Will this application require land disturbing activities encompassing an area f of five thousand(5,000)square feet of ground surface or more? 4. is there a Natural Water course running through the site or is this.project within ❑ One hundred(100)feet of wetlands or a beach? 5. Will there be site preparation on slopes which exceed fifteen(15)feet of vertical rise to -� One hundred(100),feet ofhorivontal distance? 6. Will driveways,parkingareas or other impervious surfaces direct Storm-Water Run-off into and/or in the direction of a Town Right-of-Way? 7. Will this application require the placement of material,removal of vegetation and/or the construction of any item within the Town Right-of-Way or road shoulder area? 4z (this item does not include the installation of driveway aprons.) $_ Will there be site preparation within the one hundred(100)year floodplain of any watercourse? Note: If any answer to questions one through eight is answered with a check mark In the Box,a Storm-water,Grading, - Drainage&Erosion Control Plan is required and must be submitted for review prior to Issuance of any building permit. ------------------------------------------------------------------- STATE,OF NEW YORK, COUNTYOF................................................ SS That T, ........... .....V_— .>•.....................being duly sworn,deposes and says that he/she is the applicant for Permit, (Name of individual signing Document) \ And that He/Slie is the ....... S,?„P15�,,,..,,.. . S-.L......................................................................................... (Owner,Contractur,Agent.Corportte Officer,c1c.) Owner and/or representative of the Owner or Owner's,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his knowledge and helier;and that the work sill be performed in the manner set forth in the application filed herewith, Sworn to before me this; ....... day of./..r ........................20.. Notary public: . FREDERICK J.NAPCL"ITAPIC (Signature of App icant) Notary Public,State of New York Rep.No.01 NA6089519 Qualified in Suffolk County 0 Commission Expires March 24, SURVEY OF LOT 10 Dwelling ON TERRAGE SEGTION ONE well and Sept ic MAfi� OF l�l I LL 150' + to P FILED NOVEMBER 25, IG6q, FILE No.5407 SITUATE: ORIENT TOWN: ORIENT SUFFOLK COUNTY, NY SURVEYED 07-26-2005 ci SUFFOLK COUNTY TAX # i •�y "$Q FOLIC COUNTY DEPARTMENT OF HEALTH SERVICES 1000-26-2-51 1 F _o el. I6' I{ I o Df V e PEP.1�I'I' OR APMO`V�>`L OF CONS i1C'I'1 ON FOR A SINGLE FAUIILV 112SMENCE ONLY CIER D TO: 88021'3011E 82.29" DATA' �� /6 0s -Za-os-dZo2- I Elizgll e&D.Madden .9 e\. l ibeAy Tile Agency ®� �� 01. 16' c 6'E^ APPROVED '1 a�a`^0 �� l Q Proposed FORYsI�4UR/[OF BE ROOMS o ® septic e' O EXPIRES THREE YEARS FROM DATE OF APPROVAL Test Hole O OJ 07-2G-2005 Lp ------ `\ �o &hg72e2 ,4ij/Z-yS IS fob T-w/?Z- MGDOno ld O ' o i Geoscience e 0 o \\ � o� `� VIRe-b Elevotion 1-7' OGj 1/ _ well I50'+ O 5 Brown `' o`,v o /l \: i Boa 1 N `� \\ -9 C`0 polen % O \ ..G r�0� / \ o \ �/ 1 0 r FE 'l Fine p "O \ // 1 \O O.B'E G sw To Goorse CIO O _G 7 94 o — 15.1 qroV In I`[ pole _, p\.0 Sw, .Brown -Fine 'To-' � Qc LP GOOf56 --1 i _ SrnC O I - N Nr NOTES:, oPO �C E,y `0 MONUMENT FOUND O PIPE FOUND i1 ELEVATIONS REFERENGE SUFFOLK GOUNTY TOPO MAPS n� L •'`" =T' "' AREA = 25,665 of or 0.5Q acres Qcq �SF� 5020 �.� S �E CAND SV I JOHN C. EHLERS LAND SURVEYOR : 6 EAST MAIN STREET N.Y.S.LIC.NO. 50202 GRAP_HIG 5GALE 1"= 30 _ RIVERHEAD,N.Y. 11901 ...... .. ,_______ .- 369-8288 Falc 369-8287 REF.Z:\pros\05\05-243.pro I c3R 6 SURVEY OF LOT 10 9 Z J w 1 °(v F 8 (L#-,., c a �,�N �. MAP OF WILLOW TERRACE, SECTION ONE N FILED NOVEMBER 26, Ig6G, FILE NoS4O7 r SITUATE: ORIENT W E TOWN: ORIENT SUFFOLK COUNTY, NY s SURVEYED 01-26-2005 FOUNDATION LOCATION 01-11-2001 SUFFOLK COUNTY TAX # ¶� 1000-26-2-51 D,, 've cERTHMM To: 88°21'30"E 82.29' BOB C6 JMMO p. $' 0 f of �0 9 o �6 OJ 3 z ` $ \D N O 0 Q) mo, Ta Aro \\ 3.o y�` \'fit `\ o�E J JUL � r m J , ,.gym q r C /VAJ t`Bfry so�)(`.2 •1✓ I VioRhor.lzetl alteratbn w oCCltbn tc a sway �J (' f:• map bewb,y LA lod drveyw§earl Is o c1; ,l b etbn of w Ilcemetlt Y] s bdMsbn 31 of the � i-:t3 � � secNam ro.x stagy eeweebn Em. ��� 'Oniy copies Irom the wighnl or Nb wrvey mwkatl With w wkjbnl of the bN e.,,eyw§ NOTES: e eeel II he Cons a true v raPlee' -Ce tl/lwtbns trNlcetetl hereon 19 Iry tint this MONUMENT FOUND "tom°°°°°' r by me hen rwh smte nesoobtlon or Prore»bml Lmtl Swvd �,SOIE certlib-4 sMll p arty N Hie Peron Iw Npn tb x.ve Is preor.ee, p PIPE O IIe dE�n;�`° wee:oro N Ne melynes of the bMNy Mtlbtlan.LertlFlw- �T tbro we rot troeleroWe to oCNtbrol bmGbtbm AREA = 25,665 sf or 0.5a acres JOHC. EHLERS LAND SURVEYOR '6 EAST MAIN STREET N.Y.S.LIC.NO.50202 GRAPHIC SCALE I"= 40' RIVERHEAD,N.Y. 11901 369-8288 Fax 369-8287 REF.—\\Compagserver\pros\05\05-243.pro m.�aaH axe J:Wlanzi\2007 Jobs%ORIEN'Rsite plan new footprint2dwg,5✓220074:31:49 PM 00 e�Z \2 - 'p ' s // T rp N 1 rp > o y� Irn - rn 1 �n o N O Cl- OW o ER I SITE PLAN PROP05ED RESIDENGE JEFFREY T. BUTLER, P.E. ORIENT, NY P.O. BOX 634 S.G.T.M.# 1000-26-2-31 5HOREHAM, NEN PORK TEL.: 651.205-5550 FAX: 631.-12-1.8035 GOUNTY OF SUFFOLK TORN OF SOUTHOLD SURVEY OF LOT 10 MAP OF PqI LLOW TERRAGE, SECTION ONE N F I LED NOVEMBER 25, I G69, FILE No.5407 SITUATE: ORIENT W E TOWN: ORIENT i7- SUFFOLK COUNTY, NY s SURVEYED 07-26-2005 FOUNDATION LOCATION 07-17-2007 UPDATE 02-05-2008 SUFFOLK COUNTY TAX # jR���� 1000-26-2-51 1UJ SUFFOLK COUNTY DEPT. OF SERVICES REF. # RIO - 05 -0202H 88021'30"E 82.299 o� CERTfFIED TO: , BOB CIELMiTANO ZZ e of o 6 9 ed O / 3 40' O vy /_- 0C) ®`TG la`s HgpLTH RVICES .0 29 �s UNv DEPARTME OF ORKS FOR �� AO u ., 9 gUfr,FOLK 0 UCTED� _ s / ., FhrE D .. PROVAa-OF DNS fR RESIDENCE L- $� `�yo� y° t, O A8 LE FAN► _ a D`L0 � ,.. Lo q SING �„ �, 3s .;/ o Ref.NO. H.S. om have>� es �C4. p oate APR 2 1 and v+aler supply ,err Kendes atd 10 �� �3`' A� Me age a*sp� by t . papa gEflR�Ms• 9 ce F a\ �'{ polor q l O t i���tactAry FOR�M (� try wti 4(V Haden,P E" S7 Qr�2� Nlanagem p °Wastewa� Lo>� °' MAR 13 ZOOS \01r ,,; By— W btbn OI eactbn 1209,dbdM>bn 3.Or 9. ({' •� I .. •. I j; � Men York Stote Edeetbn Tan.' - `I't !� �r ,'iii;'',If �I 'Ch4 rnPb>frwn Ne OrIgM01 OI W> _ / nee..Ite m o.guwl or 8tl Iona>�.��b NOTES: •�:-,, \ -- / _ /'/ W>MONUMENT FOUND h t e.- beYy eoae Yor q-oeeee ror Ise s„vey>oeopeea byL�Nen���k Sta50`IC certiHrngwnr elnll run oNy 0 PIPE FOUND __. -- and enIrtrtb>�ey I>9O�vepo ea. tol Ogerry pd IeMMy 0»tlWtbn Iro 1>�leG FrceOn.ord to Lhe m>Igne>OI the le^d>'9 InetVu[bn.Lertife0- tbm ore rot tromleroble to oOGitbrol beClWtbre AREA = 25,665 sf or 0.5a acres JOHN'C. EHLERS LAND SURVEYOR GRAPHIG SCALE I"- 40- 6 EAST EAD,MAIN TREEl Ol N.Y.S.LIC.No.50202 369-8288 Fax 369-8287 REF.-\\Compagserver\pros\07\07-165.pro BUILDING PERMIT EXAMINER CHECKLIST *Date Submitted:. /061&Date Reviewed:-G/1'1/06 0? Applicant: 0(ly)Wno', c y.I i 77r)4 vv�p,r�-1- Owner:T2c h�A tVi-;Eh1t�/Engineeer: SL;T-L_e 2 Estimated Cost: 1r5,00 o SCTM# 1000- - 1- 31 Subdivision: Ui��o,`,�e�-� r. one: R-j-o Conforming? //o Property Address: 995 City: 0 e-e e Pre COs? �Jv Building Permits (Open/Expired): BP -Z/C/o Z- ,Info: BP -Z/C/o Z- ,Info: BP -Z/C/o Z- , Info: BP -Z/ o Z- ,Info: BP -Z/C/o Z- Info: Single & Separate Search RequiredoY r N Determination: REQ. Lot Size: -'VoK ACT. Lot Size:05,a_65 REQ. Lot Cov ACT. Lot Cosa! REQ. FrontU ACT. Front_REQ Side/.5��ACT. Side REQ. Rear Sp PROP. Rear./ REQ. Height ACT. Height / Project Description: Up'to Waterfront? Y or ? If yes, water body: Panel# Flood Zone:_Bulkhead/Bluff Distance: ADDITIONAL APPROVALS REQUIRED Suffolk County HealthOr N- If yes, *Bed#: —4 *Date: 11110/r *Permit#: R)o- iS-0_-,')oa Town Septi�r l - If no, certif�catian-regrrired":Y 6 N"I2ecei ed:Y or N--B_y.:. NYS DEC: PRE-DEC 9/1/75 Y or&__�)- Date: /_/ Permit#: or NJ Letter—Notes: Southold Trustees: Y plo Date: / / Permit#: or NJ Letter—Notes: Southold ZBA: Y or N�- Date: _/_/ Permit#: —Notes: Southold Planning: Y or Date: / / Permit#: —Notes: Town Landmark C of A: Y or DNTE: / / *NYS CODE Compliance (page 2): Y or N Notes:,"'-p 2 '7 I Fee Structure: Calculation: 2- Foundation: la S-3 SF 1. ( �/6/y SF)- SF)=3 SF X $ _$ / O 5_ 66 First Floor: 1 1 Fl SF + Initial Fee: $—� Second Floor: I C,-3& SF + Additional Fee ( ): $ Other: SF 2. (_SF)- ( _SF)= SF X $ =$ Total: SF +Initial Fee: $ +Additional Fee $ y 60 TOTAL: $ Ih NEW YORK STATE CODE COMPLIANCE CHECKLIST CLIMATIC/GEOGRAPHIC DESIGN CRITERIA: Ground Snow Load 45 Wind Speed: 120MPH Seismic Design Category:B Weathering: Severe Frost Depth: 36" Termite: M-H Decay: S-M Design Temp: 11 Ice Shield Underlay:YES Flood Hazards: USE/OCCUPANCY CLASSIFICATION: HEIGHT/FIRE AREA: TYPE OF CONSTRUCTION: DESIGN CRITERIA: ENGINEERED/PRESCRIPTIVE FULL FRAMING DESIGN ELEMENTS: Y/N HEADERS: Y/N WALL STUDS: Y/N GIRDERS: YIN CEILING JOISTS: YIN FLOOR JOISTS:Y/N ROOF RAFTERS: Y/N LUMBER SPECIES AND GRADE: Y/N DESIGN LOAD CALCULATIONS: Y/N LIVE: Y/N DEAD: Y/N SNONAI: Y/N SEISMIC: Y/N WIND: YIN WINDOW AND DOOR SCHEDULE: MISSLE TEST REQUIREMENTS: Y/N EGRESS 5.7 S.F.: Y/N . LIGHT 8%: Y/N VENT 4%: Y/N NAILING/CONSTRUCTION SCHEDULE: Y/N MEANS OF EGRESS: Y/N PLUMBING RISER DIAGRAM: Y/N LOCATION OF FIRE PROTECTION EQUIPMENT: Y/N TRUSS DESIGN: Y/N CERTIFICATION: Y/N ENERGY CALCS: Y/N TOTAL COMPLIENCE? Y/N (RETURN TO PAGE ONE) Town Of Southold P.O Box 1179 Southold, NY 11971 * * * RECEIPT * * * Date: 05/09/07 Transaction(s): Reference Subtotal 1 1 Septic Permit- Construct- Resid. 3708 $10.00 Check Total Paid: $10.00 Name: Reichel, Walter& Priscilla (in Contract) 925 Willow Terrace Ln Orient, NY 11957 Clerk ID: LINDAC Internal ID:3708 a.r�t,aalw"a rrfancac trra; a:�r�er:a,�,�� 't?,wL a"i.'.\W.,L'aa». w\.will.:..i:. ..s,w.•er:'.—w»Jav +�..W,..i Y:Aw�: '.e.:w,4,J`, WIND SUBJECT TO DAMAGE FROM WINTER ICE SHIELD I GROUND SEISMIC FROST USE/ l SPEED EXPOSURE DESIGN UNDERLAYMENT FLOOD LIVE DEAD ROOF UPLIFT LOAD WALL SHEATHING OCCUPANCY HEIGHT FIRE AREA TYPE OF SNOW DESIGN LINE i j LOAD (MPH) CATAGORY CATAGORY WEATHERING DEPTH TERMITE DECAY TEMP REQUIRED HAZARDS LOAD LOAD SUCTION LOAD CLASSIFICATION CONSTRUCTION MODERATE SLIGHT TO FROM 113,38 PERIMITER EDGE ZONE m 312 pef EDGE ZONE m 213.1 per FIRST FLOOR m 1590 SQ.FT. 45 pi120 B C SEVERE 36° TO HEAVY MODERATE FIRM YES FIRM MAPS 40 par 20 pi ZONE m 2-3.6 per INTERIOR ZONE m 24.6 per SFD 30'3° SECOND FLOOR ■ 1318 SQ.F . TYPE V I SEE DETAIL SHEET FOR OPENING PROTECTION 8Y l HIGH WIND CONNECTION WOOD STRUCTURAL PANELS i REQUIREMENTS PERSUANT TO 1&011.4, SEE FASTENING SCHEDULE' ON V 1 DETAIL SHEET IN THIS SE CONT. RIDGE VENT SET 1� ASPHALT ROOF SHINGLES ITYP)-� --- r _—_-- --- ---- --_ - --- - - - _- 6" O.H., TYP. ll DORMERS l MASONRY CHIMNEY ------ ------ r CONT, RIDGE VENT I �o TOP OF PLATE—- -— IT — _ 1 8" SQ. HO4G COLUMNS, TYP y — -:1 1 1 - z VINYIL RAIL PER CODE Irl1T I �_IT7 7- - -1- - r. i __ TOP OF SUBFLOOR—- - _ I_. T i r T: 1- TOP OF CEILING—--� -— I _ i tl.-1 - d - -- t�11-r - - - - - - - - >l(6IGN �'O PERMIT ' 33042L-I I L. . I - ---_---- ----------- --U� -- ---- -- -- - F-M �1 — I -1-t1- - - r Il ittl_ -- i TOP OF SU6FLOOR GRADE i\;.^� O�• r✓iJiV17iH i iCJiv--- 1 I 1 . I « �`-/� 10 ♦ }'_' h 0 - --------------------------------------- ---------1 1II -IIIII I -3 !c) I aD 8" P.C. FND. WALL ' III ' I ' I I 1 1 16" X 8" r-- ---------------------------------------------------- ON P.C. FTC. 1 1 1 1 I I r--ar--• - I I I t I I III -- __-_.- - - � j�j:+�� . .. ' \V I I 1 I 1 I L I 1 I ►-- *--J - -It 1 I I 1 - - L TOP OF FOOLING — - --— �a----TaPY --------------------------------------------------------------------------------------------------• -aT -- -- - I _ _ I �I I�- ICJ �I I , 1 1 -- - 1 .-I ..---- ------ -- - - - -- a-----a-----------------------------------------------------------------------------------------_,---------a---J pp�U-- FRONT ELEVATION I ENGINEER: - - - 1 I-I_I I I t - - 'r N 1 - ----- T.Stu Y/) TOP OF PLATE -- —-_. --- -- _ I I I I� -III I I I •}� .�.�t �,� .�" - V,A cQr- a1- 073 9S II'i -- -- II �III�-tl�t1 �lll •OIT ,Qwr,F I J1+FFf� ',1=1' ...' SUTLER, F'.E. 12 TOP OF eUBFLOOR — - -— CEDAR SIDING (TYP) . - I I tIl I I I111I III I r 7 I I _ I r Lit I TOP OF CEILING - - __ - — _-- I t r I ,- ... ._ [-L1-III _II 11 .:IIL II-11 if --- - -- - - ---- -- -..--. I ._I I 1 r - 1 r I T _I L I l 11_ 11 I I - 1 1 r I- - ----- - I I l I 11 I I_ C_l z ri l VINYL RAIL � �J ll!rr I•� II �I II_Ilr II 1� It - PER CODE-01 - - _ C)--- - • --- I 1 L 1 -- -- ICI �J li I�1. It lil _ I - f _ - - - E1 -tI �-III .rIIII1II1-J - - - IL cn 0 TOP OF SUBFLOOR — - -— - - - ...-... -- - - I I I u I I I I I I MASONRY STEPS TOP OF FOUNDATION ._ _ __ - - - -- - . __---- - ... _. _:.- 111 I l t l� 11111 I I t 11 I�I rI �I A - FINISH PER AGREEMENT o c) fF � lI GRADE I 1 ---------------J I , O i AREAWELL, TYP.- 1 1 1 1 1 1 I I 1 1 1 1 1 1 ---------- — ---- --------•-----------\"r--^--__— 1 1 1 I , I 1 1 TOP OF FOOTING -- - -- •a---- a- -- - - - -------------------------a------------- • r I 1 I I I ----------------------------------\--------------------\------------------------------------J'--------------JLEFT 61DE ELEVATION l 4 I �sv §RR316 GUARDS HANDRAILS§RR315 T,45LE R402.2 §RR316.1 Guards r<equired.Porches,balconies or raised floor surfaces §RR315.1 Handrails.Handrails having minimum and maximum heights of 34 MINIMUM SPECIFIED COMPRESSIVE located more than 310 inches(762 mm)above the floor or grade below shall inches and 38 inches(864 min and 965 mm),respectively,measured vertically STRENGTH OF CONCRETE have guards not lesas than 36 inches(914 min)in height. Open sides of from the nosing of the treads,shall be provided on at least one side of stairs with a total rinse of more than 30 inches(762 min)above the floor or stairways. All required handrails shall be continuous the full length of MINIMUM SPECIFIED grade below shall have guards not less than 34 inches(864 min) the stairs with two or more risers from a point directly above the top I in heightmeasured wertically from the nosing of the treads. riser of a flight to a point directly above the lowest riser of the flight. COMPRESIYE STRENGTH �F C) Ends shall be returned or shall terminate in newel posts or safety §RR316.2 Guard opening limitations.Required guards on open terminals. Handrails adjacent to a wall shall have a space of not less WEATNERINNG POTENTIAL sides ofstairways,raised floor areas,balconies and porches shall have than 1.5 inches(38 mm)between the wall and the handrail.intermediate rails or ornamental closures that do not allow TYPE OR LOCATIONS IONS OF passage of asphere 4 inches(102 mm)or more in diameter. §RR315.2 Handrail grip size.All required handrails shall be of one of NEGLIGIBLE MODERATE SEVERE the following types or provide equivalent graspability. CONCRETE STRUCTURES EXCEPTION:Thte triangular openings formed by the riser,tread and bottom rail of at guard at the open side of a stairway are Type I. Handrails with a circular cross section shall have an outside BASEMENT WALLS, FOUNDATIONS AND OTHER CONCRETE NOT 2,500 2,500 permitted to be of stuch a size that a sphere 6 inches(152 mm)cannot pass diameter of at least 1-1/4 inches(32 mm)and not greater than 2 inches EXPOSED TO THE WEATHER 2,50� through. (51 mm). If the handrail is not circular it shall have a perimeter W dimension of at least 4 inches(102 mm)and not greater than 6-1/4 inches BASEMENT SLABS AND INTERIOR SLABS ON GRADE, EXCEPT 2,500 2,500 2,506' Q (160 min)with a maximum cross section dimension of 2-1/4 inches(57 mm). GARAGE FLOOR SLABS 0- §RR310.1.1 Minimum opening area.All emergency escape and rescue Type H. Handrails with a perimeter greater than 6-1/4 inches(160 min) BASEMENT WALLS, FOUNDATION WALLS, EXTERIOR WALLS AND U' openings shall have a minimum net clear opening of 5.7 square feet(0.530 shall provide a graspable finger recess area on both sides of the 2,500 3,000 3,00C z m2) P g Pa g OTHER VERtICLE CONCRETE WORK EXPOSED TO WEAL � profile. The finger recess shall begin within a distance of 3/4 inch J (19 min)measured vertically from the tallest portion of the profile and PORCHES, CARPORT SLABS AND STEPS EXPOSED TO 7 4E O EXCEPTION:Grade,floor openings shall have a minimum net clearE E O achieve a depth of at least 5/16 inch(8 min)within 7/8 inch below the WEATHER, AND GARAGE FLOOR SLABS 2 500 3 OOt 3 50�" opening of 5 square fleet(0.465 m2). M 0 widest portion of the profile. This required depth shall continue for at � §RR310.1.2 Minimums opening height.The minimum net clear opening height least 3/8 inch(10 min)to a level that is not less than 1-3/4 inches FOR 51: 1 POUND PER SQUARE INCH ■ 6.895 KPA. shall be 24 inches(610 nun). (45 min)below the tallest portion of the profile. The minimum width of A. AT 28 PSI, U 4 the handrail above the recess shall be 1-1/4 inches(32 mm)to a maximum 0 of 2-3/4 inches(70 min). Edges shall have a minimum radius of 0.01 inch shall be 5, SEE TABLE R301.2(I) FOR WEATHERING POTENTIAL, Oz § ll be 20 Minimums opening width.The minimum net clear opening width (0.25 min). C, CONCRETE IN THESE LOCATIONS THAT MAY BE SUBJECT TO FREEZING AND THAWING inches(50�nun). DURING CONSTRUCTION SHALL BE AIR-ENTRAINED CONCRETE IN ACCORDANCE WITH FOOTNOTED. §RR310.1.4 Operational constraints.Emergency escape and rescue D. CONCRETE SHALL BE AIR ENTRAINED. TOTAL AIR CONTENT (PERCENT BY VOLUME OF CONCRETE) to openings shall be opertational from the inside of the room without the use SHALL NOT BE LESS THAN 5 PERCENT OR MORE THAN I PERCENT, of keys or tools. z a V Y E, SEE SECTION R402,2 FOR MINIMUM CEMENT CONTENT. o N � O \ O IK Q SEE DETAIL SHEET FOR --____ A HIGH WIND CONNECTION 60' 0" , REQUIREMENTS I I I I I I 2' 0" 121811 2' Off 19' 4' 1 24' 011 I tZ7 I Q LU 1398" 5' 8" moo co, W PROVIDE ANCHOR BOLTS AT EACH CORNER 12" DIA TO UNDISTURBED SOIL U I AND AT EACH SHEAR WALL (GAIRAGE) P.C. PIER WITH 6x6 ACQ W I 6' 4" AS NOTED FOR SIMPSON PHD5 (t1'PICA.L)- SEE POST TO DECK GIRDER, i W O o x DETAIL ?HEETS PROVIDE 5/8" ANCHOR BOLTS ANCHOR PER DETAIL O I rr I W 2311 O.G. MAX, WITHIN 1' OF EACH SPLICE IN SILL SHEET, TYP. ' Cl' 1 m PLATE SEE DETAIL SHEET FOR INSTALLATION 8" THICK X 8'0" HIGH 12" DIA, TO UNDISTURBED SOIL L 00-1 ItE e f DECK ABOV � u 11 , P'.C, PIER WITH fqx& ACQ --�`-------------- P.C. WALL ON 16 x s �Y ZIiI��CCQ7s1�b1=�? : POURED CONCRETE FOOTING, TYP, 1 P105T t0 DECK fIRDER, ANCHOR -EH DETAIL 1 SHEET, TYP. 1 O O I --------------------------------- - ---2 11--- ------------I - 1 'Q � i 'I o° d � d >- o - sue• d ,. 4 e° ° p° d a 1 O 1 -.0 ' ' ------------------------- r-------------------------, I `LINE OF DE K ABOVE- N 2x8 ACQ LEDGER --`X-i-' L--------110 ° / , U ��I�--i 7- --r---------- t .- ------'1------------- -- . I . ,z�-2 ►L f�trQb1 , i 0 4 _ � �•' / I 1 Y� Q V�t Q I ------------------- ------- - ,I� I 1 3' 51, 315" O o I , , 1 I a 1 r w BEAM POCKET O I ' ' � _ ' RR408 §RR314 IQ - EXCAVATED CELLAR o 0 @ ;E 1 _ x I(X GROUT SOLID M 1 I 1 I UNDER-FLOOR SPACE STAIRWAYS X r� `tl ; 4 P,C, SLAB --------4----- Gv------ D 4-0----------� - ------------ Y � X ' " i �- -- z'x8,rkGl�-k -t'sE-tiy- ' o v - o, p , 1 §RR40&1 Ventilation.The under-floor space between the bottom of the §RR314.1 Width.Stairways shall not be less than 36 inches(914 min)in -I 1 3 1/2" STEEL COLUMN in sn 1 -� I ' ,° c ' _- ® 1 a _ _____ _ ' floor joists and the earth under any building(except space occupied by a clear width at all points above the permitted handrail height and below rite � a r'1 i 3ro""x36"x12" POURED ,', E LL i 1 .---' ---------------------------------•------------ ---- I 1 basement or cellar)shall be provided with ventilation openings through required headroom height. Handrails shall not project more than 4.5 inch cs '' I 1 1 r--•a--, O I ' ' ^ 1 1 I 114 min on either side of the stairway and the minimum clear width of the +•+-� I 1 CONCRETE FOOTING 1 1 m I ' ' FILL IN OPENINGS foundation walls or exterior wady. The minimum net area-of ( ) Y (TYPICAL) ' t ' ' ° ' stairway at and below the handrail height,including treads and landings, ' ' �,� ' N ' 1 I UJITH CONCRETE I 1 openings shall not be less than 1 square foot for each 150 square feet Y g g ' rl LL ' ' 0 67 m2 for each 100 m2 of tinter-floor ace area O'"P r cch shall not be less than 31.5 inches(787 mm)where a handrail is installed Q r N -- ANr_HOR TO EXISTI G 6 I 1 ( ' ) � on one side and 27 inches(698 min where handrails are provided on both � r_ `r," 1 _ 1 1 , TECO ALL -I,� I 1 ventilating opening shall be within 3 feet(914 mm)of e:cn corner of said ) ' 1 I O X O I 1 sides. N r� 3 1/2" STEEL COLUMN , , FLUSH CONNECTIONS _ I - , o , buildbag. t7� i i e ' Q " " 1 ' m ` Exception:The width of spiral stairways shall be in accordance with ` a I x,a 36 x42 x12 POURED , 1 d) §RR40&2 Openings for under-floor ventilation.The minbrum net area of §RR314.5. ft1 O CONCRETE FOOTING i i i ventilation openings shall not be less duml square foot(0.0929 m2)for ^ I I - 1 ' PROVIDE 3611 X 24° 'n I +""' ? i '-4 i each 150 square feet(100 m2)of underfloor space area. One each §RR314.2 Treads and risers.The maximum riser height shall be 8-1/4 inches 2-1 3/4 X I1 'f/8 BEAM POCKET 1 1 ventilating openingshall be within 3 feet 914 min (209 mm)and the minimum tread depth shall be 9 inches 229 min The,riser PROVIDE DEEPENING a E " " ;----- i c i ACCESS TO CRAWL SPACE 1 O 1 I ( ) each X its a 1__, I O building. Ventilation openings shall be covered for their height and wid P ( ) t I I(7,T PER LADE , , r 1 1 GROUT SOLID X111 . , ('�,..-_POINT LOAD .-+ m 1 I height shall be measured vertically between leading edges of the adjacent Q I I M.L. GIRD , , ' 1 I ABOVE j with any of the following materials provided that the least dimension of treads.'the tread depth shall be measured horizontally between the vertical z a r ______________, t -�- - j "--- the covering shall not exceed V4 inch(6A mm): lanes of the foremost projection of adjacent treads and at a right angle to + T I � i '2 1 I P P J J - J ' n i 1 ' 1 I 1 2-1 3/4" X I1 7/8;' ' 1 2-1 3/4" X 11 -I/ i 1 i2 1 p 1 the tread's leading edge. The walking surface of treads and landings of a ' ` 2-I 3/4 X 11 -1/8 ,LVL F.J. .--}--• ' -I - I- -1 , , �, 1r - 1 1 _ _ _ _ M.N. GIRDER ' M,L. GIRDER , , 1 1 8 11 8 cA , 1 1.Perforated sheet metal plates not less than 0.070 inch(1.8 mm) stairway shall be sloped no steeper than one unit vertical in 48 unitsLU I r ' I 1j I 1 „ I 1 I, , 1 thick. horizontal(2-percent slope). The greatest riser height within any flight �, Irl i ` I O 1 1 7 1 ' `'- "' 7 1 1 I t 1 of stairs shall not exceed the smallest b more than 3/8 inch(9.5 mm). ; 1 p I _J t.4 O - --' _i ' I 1 1 1 Y SOLID MASONRY e, >FURNACE i r IK _ I ,� I , , r--- ---+ , '� , ^ 2.Expanded sheet metal plates not less than 0.047 inch(1.2 min)thick. The greatest tread depth within any flight of stairs ahall not exceed the $ P'IER WITH T,G, o I (k! O tj I i i , • , Y 114 I I r-+ smallest b more than 3/8 inch(9.5 mm). U_ q FLUE i i e i = x I W ® I (L (� '� O i ' '° 1_ - _ �1 a/ !_X 11-I _ _ -� _ _ ,-- _ -1_3/ '4' x U JL$° _ _ _ C M 3.Cast iron grills or grating. U_ '�., 'V _J 't} P ' i I FLUSH M.L. GIRDER ' ' FLUSH M.L. GIRDER I '.1 I M §sad shall Profile.The radius of curvature at the leading edge of the 1 BEAM POCKET , , N 4.Extruded load-bearing brick vents tread shall be no greater than 9/16 inch(14.3 min).A nosing not less Ihasnul , s , 1 POINT LOAD , g 00 n (1/ r I GROUT SOLID „ „ --- --- a i 3/4 inch(19.1 min)but not more than 1-1/4 inches(32 min)shall be 14 a , , -I ,� , 1 i i X 16 CMU COLUMN ABOVE , p , 5.Hardware cloth of 0.035 inch(0.89 mm)wire or heavier. provided on stairways with solid risers. The greatest nosing projection ._1_a - 1 III N , Z ' , ° , ° ° ° i UNEX�AVATED CRAWLS ACE I ' I shall not exceed the smallest nosing projection by more than 3/8 inch 1 ° r' - '-- 36 x36 xl2 POURED U 1 1- N _ 2-1 3/4 X 11 -1/8 hLVL F,J_ _ 1 1 „ �� I I ,i ,I , I ° I (9.5 min between two stories,including the nosing at the level of floors en ' .' o - - i I 1 12-1 /4 x I1 1/8 1 I 2-1 3/4 x 11 'i/8 1 CONCRETE FOOTING O " I I 6.Corrosion-resistant wire mesh,with the least dimension being 1/8 > g g ENGINEER: 1 I t- , _ _ J_F -4 _ _ _ 1 i I 2 P.C. SCRATCH COAT , , Inch(33 mm). and landings. Beveling of nosing shall not exceed 1/2 inch(12.7 nun). `----- 1 I M.L. GIRDER , M.L. GIRDER , , �p , .6 MIL VAPOR BARRIER ' ' Risers shall be vertical or sloped from the underside of the leading edge --------------------� I _ I I I ° I 5/8'" F.G. G.W.S. •--}--+ � ' + ' •-----• ' ' � " � � i of the tread above at an angle not more than 30 degrees from the r , 1 G 1 ON 4 POUROUS FILL _ o EXCEPTIONS: pF NEI�i \ ` I I OVER FURNACE i i I �� I i i rnl I -p I vertical. Open risers are permitted,provided that the opening between , „ -i treads does not permit the passage of a 4-inch-diameter(102 nun)sphere. 1 1 PER CODE ROVIDE 36 X 24 !i t-, It- ,••-1 i - i L Where warranted by climatic conditions,ventilation npeniogs to ��Q` y , , the outdoors are not required N ventilation openings to the Cij F� '� i. ACCESS TO CRAWL SPACE O -� O EXCEPTIONS: interior are provided. 3-1/3/4" X 11 7/8 LVLi F,J. -i i 1 I I 1.A nosing is not required where the tread depth is a minimum of 11 t-- C[: i 11 1/8" TJI 230 F,J, 0 16" O.C.__ _ I --} ' i i O \I i t, i of the under-floor area where the ground surface ills treated with an inches(279 min). rl E� ii �(1� is r, 1 _ I - 2.The total area of ventilation o may be reduced to 1111,500 r 41 j I , ' t! i ° i approved vapor retarder material and the required openings are 2.The opening between adjacent treads is not limited on starts with 2t fi �ry TEGO ALL O r PILL IN OPENINGS I o I placed so as to provide cross-ventilation of the space ;he a total rise of 30 inches(762 min)or less. 07349 FLUSH CONK; N installation of operable louvers shall not be prohibited. r-1 _ I'' ItH CONCRETE ' ' RR314.3 Headroom.The minimum headroom in all arts of the stairway �Fe(+ r I =) I I I q I $ P °.. ES St 00 AN HOR TIO EXISTING -_-_---_ i 3.Under-floor spaces used as supply plenums for distri!utlon of shall not be less than 6 feet,8 inches(2032 mm)measured vertically from _ -- --- ----------- ---- o i 11 '1/8" TJI 230 F.J. I X _ ' I heated and cooled air shall comply with the requirements of the sloped plane adjoining the tread nosing or from the floor surface of the JEFFREY T, UTLER, P.E. ^ 1 I r1 I J • 16" O,C. I= ' ° • ° - - 1 o - I §RM1601A. landing or platform. 1 0 --------------------' BEAM POCKET ---------------------------------------------- tread RR314.4 Winders.Winders are permitted,provided that the width of the 4.Ventilation openings are not required where continuously operated $ Pe GROUT SOLID I; 1 ' ' mechanical ventilation bs provided at a rate of 1.0 cfm(10 m2) at a point not more than 12 inches(305 min}from the side where the O for each 50 square feet"2 Us)of underfloor space floor area treads are narrower is not less than 10 inches(254 min)and the minimum F I -___---__--- --------__-_ ------------------ -------------y-------------------------' 1 M width of ad 6inches 152mm The continuous O m I 4 ------ --- - ° and ground surface Is covered with an approved vapor-retarder f any ire is not less than ( }. v a -� - `. '• c d v a - - '. `• c 4 • c a -� - c v - ` . c 4 �>-v-_• - i materiel- d y§ R315.1 shall be located on the side where the o Z LI" tree is narrower. O o handrail require --- •---------------, '2x6 QGQ G •----- - -Zx�QGQ 1FIIGER; ;--------- , 1 1 1 I 1 I 5.Ventilation openings are not required when the ground surface is RR314.5 Spiral stairs.Spiral stairways,are permitted for interior use a covered with an approved vapor retarder material,the space is $ P P Y Pe Z Z a 1 1 I 1 I I I I 1 I 1 as a component of the means of egress from a habitable room,a basement or supplied with conditioned air and the perimeter walls are insulated an attic,provided the minimum tread width shall be 26 inches(660 min)e✓ith W Q O DROP TOP OF 1 I I 1 1 I I In accordance with§RN1102.1.7. P ~ 1 I , I 1 Q I I each tread having a 7-1/2-inch(190 min)minimum tread depth at 12 inches O , , I 1 1 1 CONCRETE 22,TYP. 1 I I 1 I U- I 1 (305 mm)from the narrow edge. All treads shall be identical,and the rise 1 ,o I I 1 1 1 , 1 1 I 1 I 1 d 1 I §RR4083 Access.An access opening 19 Inches by 24 lnches .7 min by 6 0 W > N shall be no more than 9-1/2 inches(241 mm). A minimum headroom of l6 feet, U 1 } xp @ P sp 6 inches(1982 mm)shall he provided. A spiral stair is not permitted to �Q m nun)shad be provided to the under-floor ace. See§RM1305.1.4 for I 1 I 1 1 I 1 1 1 1 I 1 I �c access requirements where mechanical equipment is located under floors. be the one means of a ss from a story of a buildin W (1 N I I 1 I 1 � I 1 1 1 1 I 1 � I Y � rY g• I I 6' Of' , , 6' Ofl , , 6' Ofl , , 6' 01,, I I 6' 0" 1 I f- I 1 I 1 I 1 I I I I I 1 §RR408.4 Removal of debris.The under-floor grade shall be cleaned of §RR314.6 Circular stairways.Circular stairways shall have a tread depth L - _ - _ - _ vegetation and organic material. All wood forme used for placing CO at a point not more than 12 inches(305 min)from the side where the treads '2-2x1O ACQ GIRDWF ___ ' shall be removed before a building is occupied or used for any purpose. are narrower of not less than 11 inches(279 mm)and the minimum depth of 1- Q All construction materials shall be removed before a building Is occupied any tread shall not be less than 6inches(152 min). Tread depth at any 9,X6 ACQ POST,TYP. 1 or used for any purpose. walking line,measured a consistent distance from a side of the stairway, W shall be uniform as specified in§RR314.2. /1 Q Q NOTE: PROVIDE 1 I/4° COIL STRAP ' §RR408.5 Finished grade.The finished grade of under-floor surface may v/ Z U IMBEDDED IN CONCRETE FOR COLUMNS located at the bottom of the footings;however,where there h evidence §RR314.7 Illumination.All stairs shall be provided with illumination in ABOVE. LOCATE PER FLOOR PLAN 1 accordance with§RR303.4. O J O that the groundwater table can rise to within 6 inches(152 min)of the IJI� finished floor at the building perimeter or where there Is evidence that • I , „ the surface water does not readily drain from the building site,the grade §RR314.8 Under stair protection.Enclosed accessible space under stairs O 2' p" 34' 0" i 24 0 in the under-floor space shall be as high as the outside finished grade, shall have walls,under stair surface and any soffits protected on the U unless an approved drainage system bs provided. enclosed side with 1/2-inch(12.7 mm)gypsum board a O r IRR408.6 Flood resistance.For buildings located In areas prone to §RR314.9 Bulkhead enclosure stairways.Stairways serving bulkhead O \ m 1 enclosures not part of the required building egress and providing access Q flooding as established in Table RR3012(1),the walls endasbag the from the outside grade level to the basement shall be exempt from the Z 60' 0" underfloor shall he provided with flood openings In accordance � requirements of§RR312,§RR314 and§RR315 when the maximum height Q from the basement finished floor level to grade adjacent to the stairway is U n covered by a bulkhead enclosure with hinged doors. I I I 1 1 FOUNDATION FLAN ' A OMMN EJ SMOKE DETECTOR INTERCONNECT PER CODE R EV I V ON TO PERMIT I T IBF 3304204GE : ww.®® OPENING PROTECTION BY WOOD STRUCTURAL PANELS SEE DETAIL SHEET FOR PERSUANT TO 160S.1.4, SEE HIGH WIND CONNECTION FASTENING SCHEDULE ON REQUIREMENTS DETAIL SHEET IN THIS SET 12 2X12 RIDGE 10 2X4 G.T. a 16" D.C. 2X10 RAFTERS 1/2" COX SHEATHING 15" FELT ASPHALT ROOF SHINGLES U CONT RIDGE VENT SHINGLE RIDGE CAPS RIDGE VENT N ATTIC z _EXHAUST AIR -� SHINGLES m FELT PAPER R-30 INSULATION � d d j -- -- TOP OF PLATE I'd, OH 3-2X8 1/2" GWB CONT. VENT ' RAFTER WD. SOFFIT (TYP.) BEDROOM 02 1 BEDROOM 03 z o O r i O i O 8" SQ.. HB 46s FIBERGLASS— O COLUMNS RIDGE BE4M 1X4 FUR T 4 G DECKING, ' 12 PAINT 3/4" t4G SUBFLOOR 3/4" SUBFLOOR —_ _— TOP OF SUBFLOOR 1 1/4" COIL STRAP /� -- -- TOP OF CEILING RIDGE VENT DETAIL 1/2" GWB 1/2 GWB 2X8 F.J., TAPPER 1/4" PER FT � �--3-2X8 R-30 fNSULATION TECO CONN cs fn W 1/2" GL.'IB 2X4 STUDS i to m UJI R-15 INSULATION ' STUDY KITCHEN 1/2" CDX SHEATHING ' O TYVEK HOUSEWRAP ' W I CEDAR SIDIN'IG ' PROVIDE m WATER/ICE ' S)HIELD P..C. SLAB, FI H 3/4" T4G SUBFLOOR ' PIER AGREEMEN -_ _- TOP OF SUBFLOOR i _- TOP OF FOUNDATION _ P INSULATION PITCH GRADE V, ' PITCH GRADE ` 581011 AWAY FROM �� COMPACTED i P, FOJNDATION FILL •� CELLAR .: 2-2X6 ACQ SILL- e� 2-1 3/4"xI1 -1/8" M.L. HDR, a; 0 12' 5 Y32" 191411 241011 5/8 ANCHOR BOLTS WITH 3 1/2" STEEL COL. ld-- 23" O.C. •` �•; ON P.G. FTC. SILL SEAL_ ,. o .� 6 4 5 1 5/32 3 6 10 2 51811 6 4 < Q D, r " , " , " r " r " , " X TERMITE SHIELD 8" CONC. FOUNDATION ' :• ' ►, S"X16" CONIC. FTC. 4" P.C. SLAB a• DA~iPRCvF BcLUW GKAVE= TOP OF FOOTING Q � � r •' �,.••v •S ••.v • ' • 0 O - - - - - - - - - - - - - - - - - - - - - - - - - - - - 'p N OC 5/4" 6" / \ 24 6-2 CN 1 5-3 I (� Q ACQ D iRINC�� / p,� -r--3 i I L4-L m cal SEE DETAIL SHEET FOR �' �,�ION � O � 'fie c4 o DiW. , I Q w 0 } Q 0 2-2x12 HDR. } STEP O HIGH WIND CONNECTION N FWCa G'a611 --,= �� I-" �- i o o ----f {K p O � � oo�P L t ---- I L e '�---------------- --- ----►-----. T— REQUIREMENTS _ - ------�--- 3 I U D LQ 2-2x12 HDR. LINE OF WALL ABOVE ---- O Q 5/4" re" N DINING `t Q W ACQ DE KING �- ,� L — — — — — — — — — — — — — — — — —� — — — — — — — — — — — — — — — •) O j 3-2X4 POST ROOM ° , 1 FWG 60611 I i - I 9b" CLG. HGT, a Q:0 t , ISLAND -; .. I f- 2-2X12 HDR. I LL r ALL DOORS ON N U I 00 xl FIRST FLOOR TO - - - - - - - O: ,1 , n I d. BE -1'0" HIGH - I 51611 5 6 121011 '-" - 2-1 3/4" X 11 l/a" LVL F,J, _ N i O -I� KITCHEN ENGINEER: 8" SQ. HB4G COL. 9'O° CLG. HGT. = i kn I BLOCK TO GIRDER BELOW, TYP, i 21911 219 2' 9" 21911 N I N Y y Vn ' i s �O T.BUTS U� 2 0 �"' '�,' 1 1 2 0 Cl N X REF. 1 W.D, i I co � ' cC '2 2 HDR, `------' 4-2X4 POST 11 ,, 4�a u O - a BEDROOM I p� I � 3-2x10__ ,�, -— -— � I `. r,Yfi. FLUSH Q ► n , " r, ► , r- Nt 2-I 3/4" X II '1/3" LVL Ir`J. - N 5 Q 310 5 8 _ Q `n ( I 9'0" CLG. HGT. I �`2 tw 9 ��Cn LU POWDER � - I ;� �F 073A n = ' oo N 4 -i U N = -I 2- 1 3/4"x 11 1/8" M.L. FLUSH IRDEk' X 2- 1 /4"x 11 1/8" M.L. FLUSH GI DER I b M p FES 4" VTR z g E.F. u - - ---- -- - - —- - —- — - - - ' N �' `n 4-2X4 POST 1 I I N `" N "' 4-2X4 POST I JEFFREY T. BUTLER, P.E. MASONARY FIREPLACE WftH 20" csJl AY � ® y' (7" n 3--- ---------------- HEARTH PER CO>DE(A1FPA 211) � o o g n � m I � _ 3" PROVIDE FRESHi A'R INTAKE r (� WG b O AND GLASS DOOR 3 F'ER CODE ^'U ^Y ^' ` -2x 12 HDR. I + / '} ° TECO ALL FLUSH ' i i i' LTV LY VERIFY SIZE x 1 , CONNECTIONS I = L>4V W.G. 11 ' 2' Qn 12' 0„ BEARI WALL / ` _ I ~ a TUB 3'i TUB SHOWER '�' u _ �. 1 �O I W b GL N M BATHROOM N U w ° SECOND FLOOR ' _ 3 2 2 GREAT ROOM LINE O FL __ _- ° E 11, 4r, - ? ° 2r 5n 9, 71' ,�—i z z N 2! 3 2 2 2 3-F.J. 1-0 Ll ° I �,(.� Q O O If 9 O CLC>z. HGT. - 1 O uj cal a ------------------------ o Q u- H 'LF WALL I U) ca U ' L�V ---- --� - Loy L,�V �----------r----, O� STUDY :-+ GL/ p: q W.G, IU.C. I SINK r-+ :t N '-'' U Q Z O TUB SHOWER ' I „ 9 O CLG. HGT. ? O I ' 11 1/8 TJI 230 - � M 11 /8" TJI 230 F.J.+� ifo" O.C. I F.J, a 1(0" O.G. I Q O W O MAIN FLOOR M a r „ r „ r 1 2 3" 2 2, 2:1 2 2 211 21' � ,1' 12 p 71811 - ' 2 62 28 2 1 28 2 c Wr^ O Q O „ 3-2X4 POST I v! J I- . 3 E}flTwlNDow I 5' 911 Lr 1„ 61 1„ G, 1,) � O O -1 � „ r ,1 EM rmow �y 7 v 1 V 1 `J I 1 2-2x1 R. ch 9 O 3 FAI I O i--" 2862 2862 2862 2862 I ° O C.O. II i � Lil 1068-3068-1068 1 O V � � PROVIDE 81MPSON PHD5 HOLpDOWNB I Q FIR6T FLOOR FLAN � LL p E FROM FOUNDATION TO FIRST FLOOR ly V COVERED PORCH I Q� AND FIRST FLOOR TO SECOND FLOOR ( ° `q 0 u � I LIVING AREA ■ 1590 SQ, FT, p G.D. G.D. AT LOCATIONS NOTED I 7 O ( z 4„ I TO AN APPROVED I m cxx 0 SMOKE DETECTOR SANfTARY SEPTIC SYSTEM I @ m I �� INTERCONNECT PER CODE U S1 a cx CAST IRON 1 3-2x8 B.U. GIRDER 3-2x8 B.U. GIRDER 3-2x8 B.U. GIRDER 3-2x8 B.U. GIRDER 3-2x8 B.U. GIRDER I CARBON MONOXIDE DETECTOR HOUSE TRAP I - - - - - - - - - - - - - — - — - — - - - - - - - - - - - - - - - 8" SQHB4G ONE PER FLOOR PROVIDE Y'INYL RAIL PER CODE I COLUMN, TYP. L — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — J FLUB BIND R15EIR DIAGRAM (NTS) S�E� , „ 61911 , „ , „ , ,r }RE1�1��101�1 TO PERMIT ��' 3042 PAGE& 37 61181169 68 37 34' 0" 241011 U ®f I 58' 0" 1: TABLE R402,2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE MINIMUM SPECIFIED COMPRESiVE STRENGTH (F'C) WEATHERINNG POTENTIAL TYPE OR LOCATIONS OF CONCRETE STRUCTURES NEGLIGIBLE MODERATE SEVERE BASEMENT WALLS, FOUNDATIONS AND OTHER CONCRETE NOT 2,500 2,500 2,501F EXPOSED TO THE WEATHER BASEMENT SLABS AND INTERIOR SLABS ON G1'-2ADE, EXCEPT 2,500 2,500 2,506 GARAGE FLOOR SLABS BASEMENT WALLS, FOUNDATION WALLS, EXTERIOR WALLS AND 2500 300a 3,006 OTHER VERTICLE CONCRETE WORK EXPOSED TO WEATHER PORCHES, CARPORT SLABS AND STEPS EXP03ED TO E Q WEATHER, AND GARAGE FLOOR SLABS 2,500 3,00 1 3,50d'', FOR SI: 1 POUND PER SQUARE INCH a 6.8"35 KP A. i A, AT 28 PSI. B. SEE TABLE R301.20U FOR WEATHERING POTE1,ITIAL. o C, CONCRETE iN THESE LOCATIONS THAT MAY VE SUBJECT TO FREEZING AND THAWING DURING CONSTRUCTION SHALL BE AIR-ENTRAINED CONCRETE IN ACCORDANCE WITH FOOTNOTE D. D. CONCRETE SHALL BE AIR ENTRAINED. TOTAL. AIR CONTENT (PERCENT BY VOLUME OF CONCRETE) SHALL NOT BE LESS THAN 5 PERCENT OR MORE THAN '1 PERCENT, E. SEE SECTION R402,2 FOR MINIMUM CEMENT CONTENT. o a O lY o� SEE DETAIL SHEET FOR r________ A HIGH WIND CONNECTION 60t 0" t REQUIREMENTS 1 - 1 1 1 I 2' Of' 12' 8" p" 19l 411 24' 0" Z I 1 I 139 811 51811 19, 011 37 All 1! 811 PROVIDE ANCHOR BOLTS AT EACH CORNER 12" pIA TO UNDISTURBED SOIL �F N w AND AT EACH SHEAR WALL (GARAGE) P,G. PIER WITH bxb ACQ AS NOTED FOR SIMPSON PHD5 (TYPICAL)- SEE: POST TO DECK GIRDER, w DETAIL SHEETS PROVIDE 5/8" ANCHOR BOLTS ANCHOR PER DETAIL m 23" O.C, MAX. WITHIN I' OF EACH SPLICE IN SIUL SHEET, TYP. PLATE SEE DETAIL SHEET FOR iNSTALLATIOIN ' 8" THICK X 8'0" HIGH � r�-tINE OF-DECK ABOV�P/-'�� P.C. WALL ON fro" X 8" zyt10 X'co (SRDEfF� �. i POURED CONCRETE FOOTING, TYP. I ' -- - ----------- I 0 - I 0 Z o e . e , / -------------------- __-_____________, , (V 2x8 ACQ LEDGER •II-,o�---_o-•-'+d �- , /01 --------------- --------- I' PROVIDE 3" . D,d III o p 1Il UJ _ / I CURB AT DOOR 1 .----------------------------- -- - 1 a �'Q BEAM POCKET O >� i RR314 §RR315 1 x GROUT SOLID , EXCAVATED CELLAR , , § �- t i I I STAIRWAYS HANDRAILS M - I I ' ' RR314.1 Width.Stairways shall not be less than 36 inches 914 min m §RR315.1 Handrails.Handrails having minimum and maximum heights of 34 ` i ri i 3 1/2" STEEL COLUMN in `^ -1 ' I �d � - � <`' o, �d <= , >_ o• I § v ( )' 8 S� - ® 1 4 D d •" .` r d D ____ clear width at all points above the permitted handrail height and below the inches and 38 inches(864 min and 965 mm),respectively,measured vertically dIlL Q11 36"x36"x12" POURED N u- ---------------------------- ---------------•------------------ Yuircd headroom hei ht. Handrails shall not ro cct more than 4.5 nthas from the rosin of the treads,shall be ovided on at least one aide of__ _ �1 g P l g PrCONCRETE FOOTING i + ^j OM i ' ' 1 DROP FND. 1 1 (114 min)on either side of the stairway and the minimum clear width cf the stairways. All required handrails shall be continuous the full length of00 i (TYPICAL) � N � i � i TO MEET SLAB 1 p i stairway at and below the handrail height,including treads and landings, the stairs with two or more risers from a point directly above the top , shall not be less than 31.5 inches(787 min)where a handrail is installed riser of a flight to a point directly above the lowest riser of the flight. L O r C • , , , 1 1 on one side and 27 inches(698 nun)where handrails are provided on 1�tlr Ends shall he returned or shall terminate in newel posts or safety r -T r_ - 1 I I sides. t-r•einals. Handrails adjacent to a wall shall have a space of not less ° r I 3 1/2" STEEL COLUMN i `C , 1 than 1.5 inches(38 min)between the wall and the.handrail. ON I ' = x _� 36"x42"xl2" POURED ' i i Exception:The width of spiral stairways shall be in accordance with � t; CONCRETE FOOTING i ' '° ' - ' 1 §RR314.5. §RR315.2 Handrail grip size.All required handrails shall be of one of �•��LL t;t1 O g types P e9 g P ty the following or provide equivalent ras abili 0 cq A ' ^+ ^°4 t §RR314.2 Treads and risers.The maximum riser height shall be 8.1/4 inches a j PROVIDE DEEPENING r_Nl ..+ 2-1 3/4" x 11 T/8" ---'', ; BEAM POCKET i a° 1 Q (209 min)and the minimum tread depth shall he 9 inches(229 mm). The riser Type I. Handrails with a circular cross section shall have an outside �-- X 1 I PER CODE , , , , I GROUT SOLID , , ,_.i , , height shall be measured vertically between leading edges of the adjacent diameter of at least 1-1/4 inches(32 min)and not greater than 2 inches Q ' I I M.L. GIRDER ' treads.Tale tread depth shall be measured horizontally between the vertical (51 mm). If the handrail is not circular it shall have a perimeter 1 t 1 1 P projection J g g ( ) 8 4 t- -----------------+ , j , I ' I ' ' lanes of the foremost ro action of adjacent treads and at a right angle to dimension of al least 4 inches 102 min and not teeter than 6-1/4 inches i '----- ' u u' I ' 1 I 1 2-1 3/4" X 11 _Z/81' I I 2-1 3/4° X 11 1/8" ' i I p 1 the tread's leading edge. The walking surface of treads and landings of a (160 min)with a maximum cross section dimension of 2-1/4 inches(57 mm). O fV 1 1 2-1 3/4 X 11 1/8 1 LVL F.J, _ - GIRDER ' 1 I M.L. GIRDER stairway shall be sloped no steeper than one unit vertical in 48 unite UJ fQ s n ' ' ' + n , I n > Il horizontal(2-percent slope). The greatest riser height within any flight Type II. Handrails with a perimeter greater than 6-1/4 inches(160 min) QL °o --iy I i 1 ( O - __; 7 1 `-- - 7 1 1 1'i ill8 11 8 ' '" of stairs shall not exceed the smallest by more than 3/8 inch(9.5 mm). shall provide a graspable finger recess area on both sides of the SOLID MASONRY a, FURNACE i _ I , , __ __ , '� 1 The greatest tread depth within any flight of stairs shall not exceed the profile. The finger recess shall begin within a distance of 3/4 inch PIER WITH T.G. ' ' Ell _ (� ' 1 I I I ,-I smallest by more than 3/8 inch(9.5 min). (19 min)measured vertically from the tallest portion of the profile and FLUE I o I ( Q I V ' , 't, , I ( 1 I 4 i 4 e �a i x i @ ( ' LL w O I , 1 , ° , I f) achieve a depth of at least 5/16 inch(8 mm)within 7/8 inch below the 1 1 •� a t +--4 I , I 1 I I §RR314.2.1 Profile.The radius of curvature at the leading edge of th,, widest portion of the profile. This required depth shall continue for at '� -tin �' e I BEAM POCKET ' ' „ I , , N tread shall be no greater than 9/16 inch(14.3 min).A nosing not less than least 3/8 inch(10 min)to a level that is not less than 1-3/4 inches 1 I t}- I I N m ; , 1 I 3 1/2 STEEL COLUMN • I M -! tv pr r I GRDUt SOLID „ „ „ ,° 3/4 inch(19.1 ram)but not more than 1-1/4 inches(32 mm)shall be (45 mm)below the tallest portion of the profile. The minimum width of 36 X36 X12 POURED , , provided on stairways with solid risers. The greatest nosing projection the handrail above the recess shall be 1-1/4 inches(32 tam)to a maximum I v `-''-a • „ u1 N tv , Z r- --, ' r-----, , , shall not exceed the smallest nosing projection by more than 3/8 inch of 2-3/4 inches(70 mm). Edges shall have a minimum radius of 0.01 inch �J I I 2-1 3/4 X I1 "1/8 kLVL F.J_ _ I 1 " i, I I �� r , CONCRETE FOOTING , p , (9.5 min between two stories,including the nosing at the level of floors (�_ - > g g (o.2smm>. ENGINEER: `l cn o - ' - i I = 1 I 2_1 /4 x I1 'i/8 1 I 2-1 3/4 x II 1/8 i I (TYPICAL) t1NEXGAV�ATED GARAGE I I I o I , I .+ F ._..�_ � _ _ _ , � , and landings. Beveling of nosing shall not exceed 1/2 inch(12.7 min). -, ---• ' --• _1 I I M.L, GIRDER ' I I M.L. GIRDER ' ' i' 1 1 Risers shall be vertical or sloped from the underside of the leading edge V V ----------------- _ tv 1 [> T l0 1 I I I 1 ' L p 1 4 P.C. S .B, 3r.�'00 �al I+e g 8 ' , I .____-' 1 I u a of the tread above at an angle not more than 30 degrees from the RR316 0 t- 1 1 6 x6 10/10' W,W,M, § �-i ' 1 ° 1 - „ I 1 vertical. Open risers are permitted,provided that the opening between T. o 1 o I OVER FURNACE t 1 = I I , 4 , O ON 4 POUIROUS FILL I '� I GUARDS BUT 1 t 1 I 1 1 0 1 0' I r•--I , , treads does not permit the passage of a 4-inch-diameter(102 min)sphere. Cry I I PER CODE I I , ta1_, I , , PITCH TO O,H.D. 1 1 r , � , , , , §RR316.1 Guards required.Porches,balconies or raised floor surfaces i EXCEPTIONS:p located more than 30 inches(762 min)above the floor or grade below shallCC N , y r- „ , °`l I have guards not less than 36 inches(914 min)in height. Open sides of a LU 3-1/3/4 X 11 'I/8 LVLI F.J. ' 1 I I I 1.A nosing is not required where the tread depth is a minimum of 1 i stairs with a total rise of more than 30 inches(762 min)above tore floor or "• r. I I� W ' t � ' I ' '� � '��`-'�' 11 'f/8 tJl 230_F.J. ® 16 O.G. tLL inches(279 min)• grade below shall have guards not less than 34 inches(864 min) t^, , _ -`1 , -� t I ' ' 2 ,� I I I r I U I I 2.The opening between adjacent treads is not limited on stairs with in heightmeasured vertically from the nosing of the treads. t-- J TECO ALL O 1 b I t ° I a total rise of 30 inches(762 mm)or less. � , , DROP FND., , � , §RR316.2 Guard opening limitations.Required guards tin open r-+ X I I FLUSH CONN� N , �° , TO MEET SLASf3 I I sides ofstairways,raised floor areas,balconies and porches shall have `ORQFES I , 4 I §RR314.3 Headroom.The minimum headroom in all parts of the stairway intermediate rails or ornamental closures that do not allow iff ' tread no from the floor surface of the shall not be less than 6 feet,8 inches(2032 min)measured vertically Iron ___ ______________, , Y passage of asphere 4 inches(102 nun)or more in diameter. ^ � �------------------------ ---------------•------- the sloped lane adjoining the sin or c o ; , i u 1/t3° TJI 230 F.J. X 11 M , o I P P J g g JEFFRE1r T. BUTLER, P.E. c s , , - 1 landing or platform. EXCEPTION:The triangular openings formed b the riser,tread � 1 I -, ® 16 O.C. ,= r , '�, t - gY V 1 I b I 'a' I � and bottom rail of a guard at the open side of a stairway are 11 BEAM POCKET i � - 1 r-------------------------------------------- -------------------------- g Pe y N th I I a. 1 „ 1 „ n Il > 1 n _ §RR314.4 Winders.Winders are permitted,provided that the width ol'the permitted to be of such a size that a sphere 6 inches(152 min)cannot pass 9 r-•I I ° 1 GROUT SOLID I; I I I 10 9 3 1 9 3 2 6�2 tread at a point not more than 12 inches(305 mm)from the side wheat the through. O I 1 , ,N i ,`,I treads are narrower is not less than 10 inches(254 min)and the minintum _ a :_____________________v_______ t------------------------ I VERIFY M.O. WERIFY M.O. M width of any tread is not less than 6 inches(152 mm). The continuous m v v v v •, v 4 v - v r v v 4 • v •" i handrail required by§RR315.1 shall be located on the side where the W N e 1 ,. a ° v ° n a �- a ° a . §RR310.1.1 Minimum opening area.All emergency escape and rescue x 00 --_-__-_-- 4 = - 1 tread is narrower. o r_______________+ r_______________, ,_______-_t_____, ,__-____________, , openings shall have a minimum net clear opening of5.7 square feet(0.530 w0 I I 1 1 1 I I 1 I I 1 I I m2). §RR314.5 Spiral stairs.Spiral stairways are permitted for interior use z zz a I I 1 I 1 I I 1 I I I 1 I as a component of the means of egress from a habitable room,a baser nent or Z 3 an attic, resided the minimum tread width shall be 26 inches(660 rom)with EXCEPTION:Grade floor openings shall have a minimum net clear W O - DROP TOP OF ' ' ' ' ' ' ' P opening of 5 square feet(0.465 m2). f I 1 1 I I `; 1 1 I each tread having a 7-1/2-inch(190 min)minimum tread depth at 12 inches q Q Q 1 1 I t 1 1 CONCRETE 22",TYP, 1 I 1 1 1 I t (305 min)from the narrow edge. All treads shall be identical,and thr rise t ,� 11 1 1 1 1 1 1 1 1 1 I - 1 shall be no more than 9-1/2 inches(241 min). A minimum headroom of 6 feet, §�10.1.2 Minimum opening height.The minimum net clear opening height l n tW` tiV 1 I I I 1 I I I I 1 I 1 I 1 )• w/ V 6 inches(1982 min)shall be provided A spiral stair is not permitted:o shall be 24 inches 610 min 1 1 I 1 1 1 1 I I 1 1 1 I ,rf I I 1 1 I I I I I I I I I be the only means of egress from a story of a building. W `t• N I 1 61 pii 1 t 6+ pi1 I I 6 s p" I , 6' p"1 I , 6' p" , , §RR310.1.3 Minimum opening width.The minimums net clear opening width �/ Q Z t 1 I 1 1 , 1 1 1 1 1 1 1 shall be 20 inches(508 min). O X §RR314.6 Circular stairways.Circular stairways shall have a tread dt plh a 1 I 1 1 I 1 1 1 1 I 1 1 at a point not more than 12 inches(305 min)from the side where the treads j f 4 O RR310 ___ are narrower o § .1. perational constraints.Emergency escape and rescue ___ ___ f not less than 11 inches(279 min)and the minimum depth of Q - O ' any tread shall not he less than 6 inches(152 mm). Tread depth at any openings shall be operational from the inside of the room without the use I walking line,measured a consistent distance from a aide of the stairway, of keys or toads. NOTE: PROVIDE 1 1/4" COIL STRAP shall be uniform as specified in§RR314.2. //� O Q O IMBEDDED IN CONCRETE FOR COLUMNS I v, ABOVE. LOCATE PER FLOOR PLAN + §RR314.7 Illumination.All stairs shall be provided with illumination in O Z V t accordance with§RR303.4. SECTION R309 9 N I GARAGES AND CARPORTS 1 J r I §R309.1 Opening protection.Openings from a private garage directly into Q , §RR314.8 Under stair protection.Enclosed accessible space under stairs l� 2, Oil I I I I a room used for sleeping purposes shall not be permittrA Other openings O � 34 0 24 0 shall have walls,under stair surface and any soffits protected on the between the garage and residence shall be equipped with a 45-minute fire- V =3 enclosed side with 1/2-inch 12.7 min sum board. ( )gypsum rated door assembly equipped with a self-closing device. §R309.1.1 Duct penetration.Ducts in the garage and ducts penetrating the walls §RR314.9 Bulkhead enclosure stairways.Stairways serving bulkhead or ceilings separating the dwelling from the garage shall be constructed of a minimum OT I enclosures not part of the required building egress and providing access No.26 gage(0.48 ram)sheet steel and shall have no openings into the garage. Q 1 §R309.2 Separation required.The garage shall he separated from the residency from the outside grade level to the basement shall be exempt from tbe� Z � 1 and its attic area by horizontal or vertical separations conforming to§R309.2.1 and§R309.2.2. 7 I 60` Oil requirements of§RR312,§RR314 and§RR315 when the maximum Lcighl §R309.2.t Vertical separations.Where partitions are used to separate vertically O I from the basement finished floor level to grade adjacent to the stairway is an attached garage from a dwelling or its attic,the partition assembly shall have V Q covered by a bulkhead enclosure with hinged doors. a 3/4-hour fire-resistance rating. 1 EXCEPTION:In lieu of providing partitions that have a 3/4-hour fire-resistance I rating,one layer of 5/8-inch-thick,Type-X,gypsum board maybe installed on the garage side and one layer of 1/2-iuch-thick,Type-X,gypsum board maybe installed on the opposite side. Application shall be in accordance with R702.3. 1 §R309.2.2 Horizontal separations.Where horizontal construction is used to FOUNDATION FLAN L A�I I _---- e separate the garage from the residence or its attic,such construction shall d ( � `--' `1 pronx;ted with one layer of 5/8-inch-thick,TYl'�X.BYt'smn board,installed in accordance with the requirements re idenc Openings in horizontal separations shalt not be permitted except where the residence is otherwise protected by vertical sepsis 57t SMOKE DETECTOR Where the horizontal separation is a floor-ceiling assembly,the structure pP 'e k (� M I v INTERCONNECT PER CODE the separation shall also be protected by not less than 5/8 inch(15.87 PAGE 4, Type-X gypsum hoard or equivalent. I� I)EPT. 1,--- Tf'""f1,'QK fin"TIH(11 n a �C WIND SUBJECT TO DAMAGE FROM WINTER ICE SHIELD USE/ GROUND SEISMIC FROST SNOW SPEED EXPOSURE DESIGN LINE DESIGN UNDERLAYMENT FLOOD LIVE DEAD ROOF UPLIFT LOAD WALL SHEATHING OCCUPANCY HEIGHT FIRE AREA TYPE of LOAD (MPH) CATAGORY CATAGORY WEATHERING DEPTH TERMITE DECAY TEMP REQUIRED HAZARDS LOAD LOAD SUCTION LOAD CLASSIFICATION CONSTRUCTION MODERATE SLIGHT TO II YES FROM 1998 40 sf 20 of PERIMITER EDGE ZONE ■ 31,2 pef EDGE ZONE ■ 29.1 pef SFD 30'3" FIRST FLOOR ■ 1035 SQ.FT, TYPE v 45 psf 120 B C SEVERE 36' TO HEAVY MODERATE FIRM MAPS p p INTERIOR ZONE ■ 29.6 F pef INTERIOR ZONE ■ 24.6 pef SECOND FLOOR ■ 1318 SQ. . SEE DETAIL SHEET FOR OPENING PROTECTION BY HIGH WIND CONNECTION WOOD STRUCTURAL PANELS REQUIREMENTS PERSUANT TO 1609.1.4, SEE FASTENING SCHEDULE ON DETAIL SHEET IN THIS SET CONT. RIDGE VENT CERTIFICATION OF NAILING & CONNECTION - - - - -- REQUIRED. _asPHalt ROOF SHINGLES (TYP) - — — -_ ALL CONSTRUCTION SHALL APPROVED AS NOTED —— M� — ET THE REQUIREMENTS OF THE DATE: I B.P.# 12— — _ = CODES OF NEW YORK STATE. FEE: I I v 5 �9 BY: NOTIFY BUILDING DEPARTMENT AT 611 o.H., TYP. _ - U14DERWRITERS CERTIEICArL 765-1802 a AM TO 4 PM FOR THE REQUI�v� FOLLOWING INSPECTIONS: DORMERS _ - - _ 1. FOUNDATION - TWO REQUIRED ® _ - - - — - - -- - - — — - — - FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING o MASONRY CHIMNEY — - _ — _ - _ _ — _ O 4. FINAL - CONSTRUCTION MUST N Occl .�NCY OR BE COMPLETE FOR C.O. a --- CONT. RIDGE VENT r ALL CONSTRUCTION SHALL, MEET THE - - WF I -_ '��AV v r v REQUIREMENTS OF THE CODES OF NEW CERTIFICATE YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. - - _- --_ _-- _ - - -- --- - - --- - - OF U;J`itj CY TOP OF PLATE—- -— -- COMPLY WITH ALL CODES OF _ - i NEW YORK STATE & 'TOWN CODE 3 � e" 650. HB4G COLUMNS, TYP _ - - _ - _ - _ DO NOT PROCEED WITH AS REQUIRED AND C0NDITIONS C F Q FRAMING UNTIL SURVEY SOUTHOLD VINYL RAIL PER CODE } o _ _ = 0�- FOUNDATION LOCATiO"J �iOVv'N ZBA_ _ = HAS E_EN APPROVED. SOUTHOLD TOWN PLANNING BOA:D � SOUTHOLD ii0VV'N TRUSTEES - - - - - - - - - N.Y.S.DEC TOP OF SUBFL0052—- -— PLUMBER CERTlFICATIO��" RETAIN STORM WATER RUNOFF TOP OF CEILING-- -- ON LEAD CONTENT E'=FORE CERTIFICATE OF OCCUPANCY PURSUANT TO SECTION45-)QC : OF THE TO`a;U CODE. SOLDER USED IN V1l TtR -- - __ SUPPLY SYSTEM CANr'VOT y ❑ ❑ _ EXCEED 2/10 OF 1!LEAD. rum ZOI\ j. o = COMPLY WITH CHAPTER � _ �� _ ``•'; FLOOD DAMAGE P►�EVENTIJ") r SOUTHOLD TOWN CODE. - - - - — ALL �uMslgc wG WASTE d _ EN �� &WATER LINES NEED u- _ TESTING BEFORE COVERING LU r TOP OF SUBFLOOf?—- ed Orr TOP OF FOUNDATION—- -— - GRADE N N z I m w � 1 1111111 11 u-� -n - O I 1 i i 10 i— �/ 1 I 1 c11 I X 1 1 Oi i 1 ------------ ------------------------------------ m I 1 $I P.C. FND. WALL i --ice-- ------------------------------------------------------ iA I I ON 16" X 8" P.C. FTG. 1 r--ar--• O CV 1 1 1 1 I M I I 1 r--ar--• , W I 1 ' ar • {/ -cfln I 1 I 1 I atiKff--- �Y 1 1 � aT • I 1 1 I ______________________________________________________________________________________________ -__ar-_ TOP OF FOOTING 1 I I I ----------------------------------------- FRONT ELEVATION - ENGINEER: TOP OF PLATE —_ -— it to - JEFFREY T. SUTLER, P.E. LL—i Lj — o 12 TOP OF SUBFLOOR —_ _— 1�— C A Si PING (TYP) W d Q TOP OF CEILING —_ _—17- -- — p W _ O r- 0 _ U } N Wa O I VINYL RAIL Q zLu a — PER CODE O 7 O UJ ui (� DQou J TOP OF $UBFLOOR —_ _— --- _ - MASONRY STEPS, TlOP OF FOUNDATION FINISH PEER AGREEMENT 0 GRADE V ILL to S I I I 1 1 1 I I I I F I I 1 I Z 1 1 --------------• 1 1 1 1 I 1 I1 L--------------' AREAWELL, TYP. OI I I I 1 1 PAGE : I 1 I 1 1 I 1 1 I I 1 1 1 1 1 1 1 1 I I I I 1 1 I 1 I I I I I I I I I 1 1 1 1 --� ---------a - ------------a, TOP OF FOOLING —- r-----'ra---------------------------------ram----------_---- r_-__---_-_..------------- -— 1 I I 1 I I ------------ ---------------------------------- _______________a______________. 1 �f LEFT SIDE ELEVATION j I I i OPENING PROTECTION MY SEE DETAIIL SHEET FOR I WOOD STRUCTURAL PANELS HIGH WIND CONNECTION PERSUANT TO 160S.1.4, SEE REQUIREMIENTS CONT. RIDGE VENT FASTENING SCHEDULE ON DETAIL SHEET IN THIS SET i MASONARY - — — - MNEY ASPHALT ROOF SHINGLES (TYP)- — — CONT. RIDGE VENT — TOP OF PLATE—- -— z - o N_ FE -1 LH� u FLASH ALL ROOF/WALL INTERSECTIONS TOP OF SUBFLOOR—- -— CEPAR SIDING (TY ) TOP OF CEILING—- 7-— TOP OF SUBFLOOR—- -— — • TOP OF FOUNDATION—-7 7-— GRADE I 1 ( � � I I I • II `------------- 1 I 1 1 X 1 ih 1 1 1 'Q !l iA 8° P.C. FND. WALL i i w ON 16" X 8" P.C. FT(3, I I T , IL. 1 I I I I O '..— ♦__TL__1 I I I r— ( •__T a__, I 1 I N 12 I I 1 1 I CD lL TOPOF FOOTING—- -— Ta--+------------------------------a-----------------------------------------------------------------------------------------------------aT----a, m fn I1 ------------------------------------------------�-----' Lu REAR ELEVATION JN CEDAR SIDING (TYP) - tu) ENGINEER: TOP OF PLATE —- A. } STEP FLASH -- [CAL s JEFFREY T. BUTLER, P.E. 12 9 TOP OF SUBFLOOR —- TOP OF CEILING — _ -— LIL Wz o 4 � U1 ? cv � N . � m Ily- Op 0 Lupw0 U) Z TOP OF SUBFLOOR —._ _— TOP OF FOUNDATION � o ELIGRADE I 1 I z 1 1 113— 3' � I I I = I I 1 1 1 ra--r------------------------------- -------------------------------;--a; lAI I --------------------------------------------------------------- ' I 1 1 I 1 I I I I I I TOP OF FOOTING --- -— ra-------------r�-------*---+--------------------------------------------------------------- --- -------------ai 1 1 I 1 PAGE RIGHT 61DE ELEVATION II 'r i i i A t BLE R402.2 MINIMUM IM M SPECIFIED COMPRESSIVE I STRENGTH OF CONCRETE MINIMUM SPECIFIED COMPRESIVE STRENGTH (F'C) WEATHERINNG POTENTIAL ' TYPE OR LOCATIONS OF CONCRETE 5TRUCTURES NEGLIGIBLE MODERATE SEVERE BASEMENT WALLS, FOUNDATIONS AND OTHER CONCRETE NOT 2,500 2,500 2 5Oa EXPOSED TO THE WEATHER BASEMENT SLABS AND INTERIOR SLABS ON GRADE, EXCEPT 2,500 GARAGE FLOOR SLABS 2,500 2 50Cf BASEMENT WALLS, FOUNDATION WALLS, EXTERIOR WALLS AND 21500 3,000 3,006 OTHER VERTICLE CONCRETE WORK EXPOSED TO WEATHER PORCHES, CARPORT SLABS AND STEPS EXPOSED TO TE WEATHER, AND GARAGE FLOOR SLABS 2,500 3,006.1 3,5OCf' FOR St: 1 POUND PER SQUARE INCH ■ 6.8S5 KPA. A. AT 28 PSI. B. SEE TABLE R301.20) FOR WEATHERING POTENTIAL. C. CONCRETE IN THESE LOCATIONS THAT MAY BE SUBJECT TO FREEZING AND THAWING DURING CONSTRUCTION SHALL BE AIR-ENTRAINED CONCRETE IN ACCORDANCE WITH FOOTNOTE D. D, CONCRETE SHALL BE AIR ENTRAINED, TOTAL AIR CONTENT (PERCENT BY VOLUME OF CONCRETE) SHALL NOT BE LESS THAN 5 PERCENT OR MORE THAN 1 PERCENT. J; E. SEE SECTION R402.2 FOR MINIMUM CEMENT CONTENT, o N_? Gl a SEE DETAIL SHEET FOR r________ A HIGH WIND CONNECTION i 609011 REQUIREMENTS 1 1 I 1 1 1 2t Oil 129 811 2' 0" 199411 2410111 Z I I W I 13' 8" 51811 19' 0" 3' 411 1' 81 1 m 1 W PROVIDE ANCHOR BOLTS AT EACH CORNER 12" VIA TO UNDISTURBED SOIL AND AT EACH SHEAR WALL (GARAGE) P.C. PIER WITH 6x6 ACQ AS NOTED FOR SIIMPSON PHD5 (TYPICAL)- SEE POST TO DECK GIRDER, DETAIL SHEETS PROVIDE 5/8" ANCHOR BOLTS ANCHOR PER DETAIL ' w 23" O.G. MAX. WITHIN I' OF EACH SPlLICE IN SILL SHEET, TYP, PLATE SEE DETAIL SHEET FOR INSTALLATION 1 m -CINE OF DECK AE30VE/ 8" THICK X 8'O°� NIGH �_ P.C. WALL ON 16 X 8 2ytI0-,4-CQ-.s RDI" `, i POURED CONCRETE FOOTING, TYP. mot-' A (�-+� 1 I , ------------------------------ o� °d - D d o• ° D / --------------------------- --- -^--------------------+ 1 � T N 2x8 ACQ LEDGER o // ' ° v ° a P // ' PROVIDE 3" i �� i Q . o. d UJ p ' ` d D ' . .1 V i 1 1 I r--------------------------- - CURB AT DOOR , n-/ r-It!_ BEAM POCKET O a Q EXCAVATED CELLAR § § 1 - XI(X GROUT SOLID %0 i i RR314 STAIRWAYS RR315 HANDRAILSIN 1 4" P.C. SLAB ' )( o• d p d , §RR314.1 Width.Stairways shall not be less than 36 inches(914 mm)in §RR315.1 Handrails.Handrails having minimum and maximum heights,of 34 3 1/2" STEEL COLUMN In `e J -i 1 1 , a d p d > ,�t• t i _ I I d p d t clear width at all points above the permitted handrail height and below the inches and 38 inches(864 ram and 965 ram),respectively,measured vertically �s I 36"X36"x12" POURED __ _ N p_ I i i- I D I required bedroom height. Handrails shell not project more than 4.5 inches from the nosing of the treads,shall be provided on at least one side of ' ' I � CONCRETE FOOTING i + i 1 D DROP FND. o i (114 mm)on either side of the stairway and the minimum clear width of the stairways. All required handrails shall be continuous the full length of �-� W � r- N , I I stairway at and below the handrail height,including treads and landings, the stairs with two or more risers from a point directly above the top > ; (TYPICAL) TO MEET SLAB o° =v I , W_ CIS to shall not be less than 31.5 inches(787 mm)where a handrail is installed riser of a flight to a point directly above the lowest riser of the flight. r T- r-+ i on one side and 27 inches(698 mm)where handrails rre provided on both Ends shall be returned or shall terminate in newel posts or safety ._ r-+ 1 1 I I , o , sides. terminals. Handrails adjacent to a wall shall have a space of not less (V Q 3 1/211 STEEL COLUMN I < t o 1 than 1.5 inches(38 mm)between the wall and the handrail. P Pi Y fA ' ' Exce lion:The width of s ral stairwa s shall he in accordance with Q/ ' a X I- 36 x42 x12 POURED I p , I 1 1 1 %3 CONCRETE FOOTING t - §RR314.5. §RR315.2 Handrail grip size.All required handrails shall be of one of L<1 0 co l I 1 I O i '°4 i the following types or provide equivalent graspability. •--1 §RR314.2 Treads and risers.The maximum riser height shall be 8-1/4 inches 1 I - E „ „ r_____ I BEAM POCKET (209 mm)and the minimum tread depth shall be 9 inches(229 mm). The riser I. Handrails with a circular cross section shall have an outside �-- X a , PROVIDE DEF-PNING 1__ , I a t I ° ' P Tyler r-rtl + 2-1 3/4 x Il 1/8 t , 1 I O I 1 1 o I PER CODE , 1 1 GROUT SOLID �, , , height shall be measured vertically between leading edges of the adjacent diameter of at least 1-1/4 inches(32 ram)and not greater than 2 inches 1� 1 I M,L, GIRDER t I D 1 treads.The tread depth shall be measured horizontal] between the vertical z _I__ _ , r_____, I I P Y (51 mm). If the handrail is not circular it shall have a perimeter d _________________i , , T I I , , I D I i p t planes of the foremost projection of adjacent treads and at a right agle to dimension of at least 4 inches(102 mm)and not greater than 6.1/4 inches ) ------ I 1 I u 1' n u I 1 1 2-1 3/4" X 11 1/8" LvL F.J. 2-1 3/4 x 11 1/8_t 1 2-I 3/4 x 11 'f/8 the tread's leadingedge. The welkin surface of treads and landingsofa (160 ram with a maximum cross section dimension of 2-1/4 inches 57 ram O (V M, , GIRDER 1 1 M,L. GIRDER p' i i i stairway shall be sloped no steeper than one unit vertical in 48 units UJ (� , t1 1 + tt , , + n s n I I horizontal(2-percent slope). The greatest rise[height within any flight Type I1. Handrails with a perimeter eater than 6-1/4 inches(160 mm) m "Z 1 0 0 1 `-- -- 1 I 't 111811 11 8 1 o It of stairs shall not exceed the smallest b more than 3/8 inch(9.5 min shall provide a graspable finger recess area on both sides of the SOLID MASONRY 1 `- __ ; t Y )• P g Pa g >FURNACE (Y _ 1 __ __ � 1 I-- The greatest tread depth within any flight of stairs shall not exceed the profile. The finger recess shall begin within a distance of 3/4 inch ff PIER WITH T,G, i ^I 0 I tY p U i i p i i ° - •-{ smallest by more than 3/8 inch(9.5 mm). (19 mm)measured vertically from the tallest portion of the profile and p FLUE •4 i p e _a LL 1� O M achieve a depth of at least 5/16 inch(8 min)within 7/8 inch below the T t i §RR314.2.1 Profile.The radius of curvature at the leading edge of the widest portion of the profile. This required depth shall continue for at I 1 I I / M BEAM POCKET „ 1 I I � eV - tread shall be no greater than 9/16 inch(14.3 ram).A nosing not less than least 3/8 inch(10 ram)to a level that is not less than 1-3/4 inches u N , ' 3 1/2 STEEL COLUMN •----- ' 0) -1 , , I 1 3/4 inch(19.1 mm)but not more than 1-1/4 inches(32 min)shall be (45 mmi below the tallest on of the file. The minimum width of i 00 lu t O N I Q/ r I GROUT SOLID 1 „ 11 I I :� ) portion Pro f(1 , I 36 x36 A2 POURED I D I 1 provided on stairways with solid risers. The greatest nosing projection the handrail above the recess shall be 1-1/4 inches(32 mm)to a maximum 1 D `4'='-.a • - u ul N N 1 Z r-----• I I CONCRETE FOOTING 1 I ` shall not exceed the smallest nosing projection by more than 318 inch of 2-3/4 inches(70 ram). Edges shall have a minimum radius of 0.01 inch 2=1 3/4 X 11 -1/B�LVL F,J_ - I I �� 1 I 11 I I 1 o I M (9.5 min between two stories,including the nosing at the level of floors I 1 2-1 /4 x 11 1/$ I I 2-1 3/4 x 11 1/$ , , (TYPICAL) UMIEXCAVATED GARAGE > g g to.2s inm). ENGINEER: o , I 1 {- t _ _ �- _� _ _ _ I I I I 1 and landings. Beveling of nosing shall not exceed 1/2 inch(12.7 mm). ----- T___________________ I 1 M.L. GIRDER M.L. GIRDER 4X" P.C, SLAB, 3500 p81 i °a Risers shall be vertical or sloped from the underside of the leading edge" 1 t, I 1 1 5/$" F.C. G.W.B• r-- -• ' + ' `-----' ' ' ° " of the tread above at an angle not more than 30 degrees from the t- + , I I rob x6 10/10 W.W.M. I o I §RR316 �d ay 1 a 1 1 1 I I 1 4 , - a I p 1 vertical. Open risers are permitted,provided that the opening between GUARDS '� '�'• ''�t �f 1 a 1 OVER FURNACE 1 I = I , , p O)N 4 POUROUS FILL I 1h �'��.. �''„' �.o� PER CODE i i 4-- r 'e�i_; i O I 1 ,--1 s 1 I ` treads does not permit the passage of aflinch-diameter(102 ram)sphere. tl(r �' cM a 1 (L , I I P ITCH TO O,H,D, I ,- 1JRR316.1 Guards required. 1 1 ° located more than 30 inches(762bentm)abo a the floor oflgrade belaow ahutll, , O 1 t EXCEPTIONS: have guards not less than 36 inches(914 mm)in height. Open sides of F t3-1/3/4 X 11 1/8 LVL' .J. 1.A nosing is not required where the tread depth is a minimum of 11stairs with a total rise of more than 30 inches 762 rnm above the floor errinches(279 mm). grade below shall have guards not less than 34 inches(864 ram)1.__ U_� I1/8" TJI 230 F,J, 16 D.G. ' i ° i i D i, _ 1 • in heightmeasured vertically from the Hoeing of the treads. o a � n• a"• ` 1 I I} ' li ' D I i o i 2.The opening between adjacent treads is not limited on stairs with tECO ALL ; ° ( ) ,` O DPf2OP FIND, i a total rise of 30 inches 762 ram or less. §RR316.2 Guard opening limitations.Required guards on open /p` c e<•Rb:t FLUSH CONN,' N I c I TO 1 MEET SLAB sides ofstairways,raised floor areas,balconies and porches shall have 1 1 X I W 1 r I I 1 , .1 , §RR314.3 Headroom.The minimum headroom in all parts of the stairway intermediate rails or ornamental closures that do not allow • I pp shall not be less than 6 feet,8 inches(2032 mm)measured vertically from �I� /11 Z/13" tJl 130 E,J. ' ' 4 `------------------------ --- ------- --------------- ---------------' ' thetread from the of asp here ( 2 ) r more in diameter. passage ash s 10 ram o sloped plane adjoining the nosing or JEFFREY T. SUTLER, P.E, 1 rq -I „ ix I i v - I landing or platform. EXCEPTION:The triangular openings formed b the riser,tread p i -1 •16 O.C. , I r i o, - , gY BEAM POCKET � � r - 1 r- ' and bottom rail of guard at the open aide ofastairway are N I - I ! n r n r 1 1 s n s n _ §RR314.4 Winders.Winders are permitted,provided that the width of the permitted to be of such a size that a sphere 6 inches 152 min)cannot ass 9 1 Q I 1 1 Pe P ( P GROUT SOLID I I ; i °° I O/ 9 3 1 9 3 2 6�2 tread at a point not more than 12 inches(305 rem)from the side where the through O a :- ---------------- ------- v a-- -----------------------------------7-------------------------- < - VERIFY M.O. VERIFY M.O. width tread 6m inches Thecontinuou m the um __ __ M n ) s I ,• 4 o v a e • . ° v a o v a •v - ° . v a o•, v a •v G> , v a v a •v , handrail requnarrower. by§RR315.1 shall be located on th aide where the §RR310.1.1 Minimum opening area.All emergency escape and rescue � � e? tread is nano openings shall have a minimum net clear opening of 5.7 square feet(0.530 tL pi §RR314.5 Spiral stairs.Spiral stairways are permitted for interior use ) z W z a I I as a component of the means of egress from a habitable room,a basement or Z 1 a I - UNEXCAVATED NOTE: PR VIDE 1 1/4" COIL STRAP °Q EXCEPTION:Grade floor openings shall have a minimum net clear Q an attic,provided the minimum tread width shall be 26 inches(660 mm)withW a I 1 _ opening of 5 are feet(0.465 m2). IMBEDDEDI IN CONCRETE FOR COLUMNS I o 1 each tread having a 7-1/2-inch(190 ram)minimum tread depth at 12 inches P g �" Q --1 � � COMPACTED FILL I ' ' O (305 mm)from the narrow edge. All treds shall be identical,and the rise t ,o D, , ABOVE. LmCATE PER FLOOR PLAN 1 1 §RR310.1.2 Minimum opening height.The minimum net clear o height U! } ev , , 1 shall be no more than 9-1/2 inches(241 mm). A minimum headroom of 6 feet, g gng> shall be 24 inches(tile ram). (� N ' > 6 inches(1982 ram)shall be provided. A spiral stair is not permitted to 1a-. ? %0 oa 1 o I i be the only means of egress from a story of a building. W 'Q Q . CV i t t I §RR310.1.3 Minimum opening width.The minimum net clear opening width �/ Z t 4 ----__ ---- --------- ---------------------- --------------t-------------------------- RR3146Circular shallbe20inches(508mm). ('�' 1 ---- --- --- I § stairways.Circular stairways shall have a tread depth s••� Uu O -= - u v `< . v ° v , at a point not more than 12 inches 305 min from the side where the treads ' v a ° ° a ° • v a o -' a ( ) §RR310.1.4 Operational constraints.Emergency escape and rescue O I ---- __, are narrower of not less than n inches (15 ram)and the minimum depth of openings shall be operational from the inside of the room without the ulse 0 ~ N O 1� `-------------------------------------- ----------------------- -----+--------------------------- , any tread shall not be less than 6 inches(152 ram). Tread depth at any � � walking line,measured a consistent distance from a side of the stairway, of keys or tools. j shall be uniform as specified in§RR314.2. C) Q O 1 v 1 i RR314.7 ordance accordance with§RR303�4 SECf1ON R309 stasis shall be provided with illumination in O U I GARAGES AND CARPORTS J t Enclosed accessible sp ace §R309.1 Opening protection.Openings from a private garage directly intoO O r _ t §RR314.8 Under stair p . pace under stairs I a room used for sleeping purposes shall not he permitted. Other openings O 2' O11 ' 24, (�1r shall have walla,under stair surface and any soffits protected on the 34 0" , enclosed side with 1/2-inch(12.7 mm)gypsum board. between the garage and residence shall be equipped with a 45-minute firo- rr ♦J N N rated door assembly equipped with a self-closing device. R309.1.1 Duct penetration,Ducts in thegarage and ducts u- 0 $ ix penetrating the walls /� §RR314.9 Bulkhead enclosure stairways.Stairways serving bulkhead or ceilings separating the dwelling from the garage shall be constructed of a minimum 1 enclosures not part of the required building egress and providing access No.26 gage(0.48 mm)sheet steel and shall have no openings into the garage. I from the outside grade level to the basement shall be exempt from the §R309.2 Separation required.The garage shall be separated from the residence Z 1 and its attic area by horizontal or vertical separations confomring to§R309.2.1 and 11 R309.2.2. ' 609011 requirements of§RR312,§RR314 and§RR315 when the maximum height §R309.2.1 Vertical separations.Where partitions are used to separate vertically O 1 from the basement finished floor level to grade adjacent to the stairway is an attached garage from a dwelling or its attic,the partition assembly shall have U O covered by a bulkhead enclosure with hinged doors. a 3/4-hour fire-resistance rating. I EXCEPTION:In lieu of providing partitions that have a 3/4-hour f re resistance 1 rating,one layer of 5/8-inch-thick,Type-X gypsum[ward maybe installed on the garage side and one layer of 12-inch-thick.Type-X,gypsum board maybe installed on the opposite side. Application shall be in accordance with 11702.3. I §R309.2.2 Horizontal separations.Where horizontal construction is used m FOUNDATION FLAN L A�I 1 A separate the garage from the residence or its attic,such construction shall d I �l `-------- protected with one layer of 5/8-inch-thick,Type-X,gypsum board,installed in accordance with the requirements where re§Bence Openings in protected separations Shari] �AGE , not be permitted except where the residence is otherwise protected by vertical separations. SMOKE DETECTOR Where the horizontal separation is a floor-ceiling assembly,the structure supporting; INTERCONNECT PER CODE the separation shall also be protected by not less than 5/8 inch(15.97 mm) Type-X gypsum board or equivalent. 3 0� �( I ` OPENING PROTECTION BY WOOD STRUCTURAL PANELS SEE DETAIL SHEET FOR PERSUANT TO 160S.1,4, SEE HIGH WIND CONNECTION FASTENING SCHEDULE ON REQUIREMENTS DETAIL SHEET IN THIS 5E7 i I 12 2XI2 RIDGE 1 2X4 G.T. 16" O.G. 2XIO RAFTERS 1/2" CDX SHEATHING 1150 FELT ASPHALT ROOF SHINGLES CONT RIDGE VENT ATTIC SHINGLE RIDGE CAPS RIDGE VENT _EXHAUST AIR SHINGLES R-30 INSULATION FELT PAPER-\ —- -— TOP OF PLATE 1'0" OH 3-2X8 1/2" GWB CONT. VENT ' RAFTER WD. SOFFIT (TYP. BEDROOM +2 BEDROOM 03 - di I o 8" SO.. HB 4G FIBERGLASS 00 COLUMNS i a I RIDGE BEAM 1X4 FUR T 4 G DECKING, - ' 12 PAINT ; 3/4" T4G SUBFLOOR 3/4" SUBFLOOR 1 1/4" COIL STRAP ' -- - - TOP OF SUBFLOOR I /� �� -- -- TOP OF CEILING RIDGE VENT IDE It AIL 1/2" GWB 1/2" GWB R-30 INSULATION 2X8 F.J., TAPPER 1/4" PER FT- 3-2X8 'TECO CONN c2 w 1/2" GWB 0 2X4 STUDS I m R-15 INSULATION ' STUDY KITCHEN o � w 1/2" CDX SHEATHING ; TYvEK HOUSEWRAP ; w CEDAR SIDING PRO+VIDE m WATER/ICE ' SHIM( D P.C. aLAB, FI H 3/4" T4G SUBFLOOR PER ,AGREEMEN -_ _- TOP OF SUBFLOOR _- TOP OF FOUNDATION R-30 INSULATION GRADE 14 •; PITCH GRADE AWAY FROM •� CO>MPAGT3=D 'p P,• 581011 FOUNDATION FILL .� •s tu •.• CELLAR - 24' 0" , 2-2X6 ACQ SILL � e;' 2-1 3/4"Al 1/8" M,L, HDR, n� 12' 8" 2' O" 19'4'I 5/8 ANCHOR BOLTS WITH 3 1/2" STEEL COL oo " 23 O.C. �� . �� ON P.G. FTC. SILL SEAL ., p °•• 61411 61411 3' 611 101211 51811 201811 31411 TERMITE SHIELD •� � LL LL 8" CONC, FOUNDATION . :• 8"Xlb" GONG. FTC. a' 4" P.C. SLAB a' 111 r DAMPROOF BELOW GRADE - °' —- -— TOP OF FOOTING I StEFP �• •d1 l'r. •'M�1 r. DO - - - - - - - — — — — — — — — — — — — - - - - - - - - � 3: N 5/4" 6" / , 24 6-2 d- CN 1 5-3 �• I I _ (K ACQ D KINCs— / b� SEE DETAIL SHEET FOR SECTION A- p Q / .yr7 ��, 2-2x12 HDR. a d , pI,W. , HIGH WIND CONNECTION N N FWG 0611 / �s.�P�� --�- ' o o •----, I � �- REQUIREMENTS / ---�e `� ----- -- ,��1---------------- •---- ----kasaza __ X 2-2x12 HDR. LINE OF WALL ABOVE I d. 0 4„ I �, ` to z co F_ , 3-2X4POS I DININGL I 1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6 N O I L f � ROOM - a I m S'O" CLG. HGT, a O I 3' 0ell 1 (y Xi ISLAND .• I� I U- 14 ALL DOORS ON 00 r^ � FIRST FLOOR TO - - - - - - - 0: 0uj -' co 2-1 3/4" X 11 l/d8" LVL F.J. - '�I BE O NIGH ; p NOTE: FRAME ROOF SYSTEM N I KITCHEN ; OVR GARAGE ON TOP OF a 2 CAR GARAGE I „ „ , p FLOOR JOISTS, SEE DETAIL -i 3/4 HOUR RATING ON WALLS I ENGINEER S 8 60, HB4Cz COL, 9 O CLG, HGT. I BLOCK TO GIRDER BELOW, TYP. ; 4 CEILING PER CODE, SEE NOTES ON THIS SHEETIt #SECTION R309 fY' z REF, i W.O. QI O = -2x12 NDR, `----- Oi t tt.r 3-2x10 BEARf WALL 3 1/2" STEEL COLUMN �^• �r n 5, On 4„3, O„ „ �Yg, U' J 24"x24"x12" POURED 3-2X4 POST 2-1 3/4 X 11 1//8 LVL F.J. - I ,"a < •»• , I POWDER LAU DRY U _ CONCRETE FOOTING •--' ' - I f- ' V - 4 (A N II u '- -i u u GO 2- 1 3/4 x I1 �/8 M.L. GIRDER I I 2- 1 3/4 x 11 '1/8 M.L. GIR ER I p M 4" VTR E.F. - - - - - - - - - - - - - - x o0 I u' O °O -�- �° , N N x - O- = T(2x10 R DGE ABOVE) 1 ~ M1Sryy~ H z X D ' ' ---- ' - ' I JEFFREY T. BUTLER, P.E. MASONARY PIREPLACCE WITH 20" I ���/// `� e VENT - 2-2X8- -2 2x8 - I 3 -_--- HEARTH PER CODE tTT1FPA 211) W G C 70 EX7. -�� - .-------- ^-- 3 PROVIDE FRESH AIR INTAKE I .�. I U I i"I'. I I OQ T4- AND GLASS DOORS FPER CODE Al -2x 12 LAy� i i i L' V L�V - v VERIFY SIZE �O BEARING WALL ul F W.C. W:c. _; I a 2, 0,1 _ 12' 0" u h 231811 �o _ I W TUB 3", TUB SHOWER ! rn N _ d' ( ' tdl L 7v c"n �9 t a 'e (X (t0 (Y I v O I SECOND FLOOR ; — " °� wr CL la ,� I Z z 2 I 2,� 2 3 CsREAt ROCOM LANE of >_� --------- ® --- ---- -------------� ----- -------- 2 2 - - _ - - - - I I O ------- 3 2 9'O" CLG. HCGT. A� 3-F.J. —9 ------- ---.,i2 6 I2�c6 ►il - ----�li2�c6 ►I2�c�i,,----- I �_ 1 ----- ------- -------- r--- - - _ _ .R. R.R. : i :R.R. R.R, i ' i m O 3 ---' - -- ------------- ----- STUDY XI I L.IJ N�V--_ W.G, --_SINK I .�-I ,� O N 1 •�-I i'�--- -_-''I �'`--- -_- 1 Q Z " I tL 90 CLG. HGT. •k__------�. ��_------_�= j �/8" 7JI 230 � D.W. 11 /S" TJI 230 F.J. * 16"" O.C. ,�I F.J, 0 16" O.G. -2x12 HDR. ' 2-2x12 HDR. l Q ��_ W 0 MAIN FLOOD: 211 Co 12' 0' 4„ 71811 4„ 1 W (Y 2 2 _ _ _ _ _ _ _ _ _ _ _ J 3 3-2X4 POST r - —61 6,1 9'x8' ,H.D.- - - - lO�411 - - - - 9'x8' H,D. - -7i 2n - - - - - o Q 3„ wn�mow N 2-2x l EXrr wuNmow I 3 FAI I --- 2862 2862 2862 2862 1 O 0 I W 1068-3068-1068 a �y+ V d C.O. I PROvIDE SIMPSON PHD5 HOLDDCWNS 1 (� I l) LL 0 I FROM FOUNDATION TO FIRST FLOOR (Y 7 d COVERED MA50NRY PORCH w 1 Q_ O AND FIRST FLOOR TO SECOND FLOOR I d G.O. G.O. AT LOCATIONS NOTED l O /P.C. SLAB 1 FIRST FLOOR FLAN ` `( E 4„ I TO AN APPROVED 1 1A r r O SANITARY SEPTIC SYSTEM (FINISH PER AGREEMENT) ED LLIVING AREA - 1038 50, FT. IL,` e I GARAGE AREA - 552 SQ.FT. 2" u CAST IRON m 3-2x8 B.U. GIRDER 33-2x8 B.U. GIRDER 3-2x8 B.U. GIRDER 3-2x8 B.U. GIRDER 3-2x8 B.U. GIRDER ' I � 6 U HOUSE TRAP I - - - - - - - - - - - - - -- - -- -- - - - - - - - - - - - - 8" SQHB4G SMOKE DETECTOR �- I I COLUMN, TYP. INTERCONNECT PER CODE L — — — — — — PROVIDE V— — RAIL PER CODE — "7 �LUI"f 31NC i�f5 Df�4C�fi��41,1 CN�"5� - - - SEP - - - - - - - - - - - - - - - - - - - - - - J CARBON MONOXIDE DETECTOR ® ONE PER FLOOR 3 1 11 6" 011 619" 6' 911 61811 31711 FAGEO 7 V O V 7 V 7 l7 O 34' 011 241011 4 O f 581011 24'0" 2'4''' 171011 7'0" 31811 41011 c ` TABLE R301.4 CABLE R301,6 MINIMUM UNIFORMLY DISTRIBUTED LOADS (PSIS ALLOWABLE DEFLECTION OF STRUCTUAL MEMBERS - ----------- ______ USE LIVE LOAD STRUCTUAL MEMBER ALLOWABLE -� _ _ EXTERIOR BALCONIES 60 DECKS 40 DEFLECTION ' 2 32 2812 2062 i i PASSENGER VEHICLE GARAGES 50 RAFTERS HAVING SLOPES GREATER THAN 3/12 C:W 45 �' ATTICS WITHOUT STORAGE 10 WITH NO FINISHED CEILING ATTACHED TO RAFTERS L/Iw - ATTICS WITH STORAGE 20 BATH � ROOMS OTHER THAN SLEEPING ROOMS 40 INTERIOR WALLS AND PARTICIANS H/I80 U V C 11l W,G, FLOORS AND PLASTERED CEILINGS L/360 ui SLEEPING ROOMS 30 �n STAIRS 40 0 dN—i 141211 ° o0 0 71211 61/ 11'0" ---------------------------- GUARDRAILS AND HANDRAILS 200 ALL OTHER STRUCTURAL MEMBERS Ln40 1 � U (L — MASTER d • 0 M EXTERIOR WALLS WITH PLASTER OR STUCCO H/360 1 BATH a v d BEDRooM 3 N TABLE R301,5 FINISH 0 m \ %0 8'0" CLG, HGT, b1 1 e 41811 611 MINIMUM ROOF LIVE LOADS IN POUNDS-FORCE EXTSEHRIISOR WALLS-WIND LOADS WITH BRITTLE Ln40 How ' ' PER SQUARE FOOT OF HORIZONTAL PROJECTION 2' (o" I ' - O" U LOW PLATE 1 1 EXTERIOR WALL84UIND LOADS WITH O TRIBUTARY LOADED L/120 � FLEXIBLE FINISHES cx AREA IN SQUARE v FOR ANY STRUCTURAL ET I 71 611 N 231811MEMBER NOTE: L■ SPAN LENGTH, H• SPAN HEIGHT U M 0 O TO 201 TO OVER A. THE WIND LOAD SHALL BE PERMITTED TO BE TAKEN AS O,"1 TIMES �0 61 pn ROOF SLOPE 200 600 600 THE COMPONENT AND CLADDING LOADS FOR THE PURPOSE OF THE (Il 3'0 71 p,1 - O DETERMINING DEFLECTION LIMITS HEREIN. BONUS ROOM Lu in FLAT OR RISE LESS THAN 4 INCHES PER FOOT 20 16 di O z U 2' 6" CL `� CLG. HGT, n:3) 12 RISE 4 INCHES PER FOOT(1:3)TO LESS THAN _ —2_2XIO UPSET- N N 16 12FRAME WALL ABOVE TO G.J. �UJI - 12 INCHES PER FOOT 11+l) OPENING PROTECTION BY SEE DETAIL SHEET FOR _ WOOD STRUCTURAL PANELS HIGH WIND CONNECTION d (L/ Q dFTjIG' O _ _ _ _ _ _ _ _ _ _ _ _ _ RISE 12 INCHES PER FOOT(I:U AND GREATER W 11 0, aG`CE$°S` - N 12 12 Iz PERSUANT TO 160S,1.4, SEE REQUIREMENTS FASTENING SCHEDULE ON N M N DETAIL SHEET IN THIS SET 00 Cl -� z O " " 1 N Q .x9 2xl2 RIDGE 2 6 GL o - -----u D---------------------- V ----------- iN 6 oilZ aD O 1 + N 151011 a _ �11 [11 31711 71 O11 L J / O U SEE DORMER FRAMING PLAN BELOW w MASTER a `v u m z N ou = BEDROOM (L 0 LOW PLATE o VAULTED CLG, 0 - BEDROOM 02 ® 12'0" ,A.F.F. x N N 1 1Lu ------------------ ------------- -------------------- --s= --- a 0 8 O" CLG. HGT. b 1 1 An 1 : O(1 O U ® 24 10 2 310 UJI GL w cxv ----- ------- ----------------------------- --------------------- m 2115" 11'7" M EXIT WINDOW ' EXIT WINDOW I -2x10 HDR 1 28 2 28 2 FWH 31611 2862 2 ' I If l 1 I 5EC0 D FLOOR PLAN. U_t COVER PORCH -> u 1 WOOD RAIL I , x (5/4"xb" REMOVE BLE DECKING U o x I cc LIVING ARE 998 SQ, FT, PER CODE I I ON RUBBER M RANE ROOF) cn I I BONUS RD M = 390 SO. FT. X I ® SMOKE ETECTOR Q 1 ' ( INTERCONNECT PER CODE LL -2x8 3- x8 3-2 8 3-2 3-2x - 1 POSTS TO - - - - - - - - - - - - - - - - - - ALIGN WITH I 1 GARB MONOXIDE DETECTOR BELOW — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — - ' ONEPER FLOOR >~ L ! p mN T 7" 61 8,1 61 911 61 911 61 Sit 31 711 21 011 21 011 T O" 21 0,1 (� , 7 V 7 V O L ca cA 34'0" 4'6" 4101, '0" 6'4" 41011 5'2" _ _ __ \0 ' 11 O - 11 N PANEL IL m WIND-BORNE DEBRIS PROTECTION FOR WOOD STRUCTURAL FOR WALL OPENING PROTECTION) OF120 MPH 3-SECOND WIND GUSTS( MAXIMUM MEAN ROOF HEIGHT: 35) ----------------------------------------------------------------- : 1 1 1 11 SHUTTER ASSEMBILY ENGcfNEER: ` N.T.S. FOR PANEL SPANS: l cx i i t'�� ' `( �• ,` 0<40 WIDE S;PAN J Iro 23/32"APA SPAWRATED 48/24 SHEiATHING GRADE PLYWOOD 1 (OVERLAP AROUND OPENINGS 4") 1 . ASSEMBLY: ATTACHING STRUCTURAL PANEL: (FASTEN TO BUILDING w/ #10x3-(w/WASHERS)GALVINIZED i OR STAINLESS STEEL I WOOD SCREW @ 16"O.C. ALTERNATIVE FASTNER FOR SHUTf'TER TO BUILDING: ' ' -- .. 1i #10 TEE NUTS ATTACHED TO BLD(G.w/#10x1-1/2 (W/WASHERS) •� ' JEFFREY T. BUTLER, P.E. MACHINE BOLT @ 12"O.C. ' - - - - — - - - - - - _ - 11 1 i - _ - 2X12 RIDGE m -�- —I-- - - -- - -T- - - -- --- - -- - - -- 13 r--- --r-- - - - W ILL zz Lu _ o �IuJ ULTIPLE SECTION ASSEMBLY: U U , ' Lu—1 > m 1/4" THICK BOLtS 2' OC (n (3 — - , I I I I 1 2-2}c8 HDR. 1 } 1 2-2X8 HDR. 1 ; = O '1 2-ZX8 HDR. > j j W Q }- N z cc Z iw ��� r �aQ w O N 1 W Q O II -- ------------------------------------------------------------------- ' I I I I� la o I :� la o d I � I� -- -------------------------------------------------------------------= � � z V A O 4 SHUTTER ASSEMBLY I I ,, I '1 I' 'x4-161. _R. b R.R� 'X6 R.R b R.R.1 y 1 6 In R.R,x6 R.R. J a 1l Q Q I p.OV Ib O.0 • Ib O.OI 16 O.C. 16 0.01 Ib O.C. O p FOR PANEL SPAINS: ' ' ' I O 4' OR WIDER SPAN I i I( I I 23/32" APA SPAN-RATED 48/24 18HEATHING GRADE PLYWOO I a'' 1.1'' �}' I ' ' ' ' ' 1 (OVERLAP AROUND OPENINGS 411) 2x4 STRONG-IBACKS ® 24" OG I' 'I ' I I I I I I _ ASSEMBLY: ll I I I I I zoo 24310 I I 24310 I I 24310� I 1 1 12 1). PREASSEMBLE PLYWOOD TOlf 2x4'5: M lox3" (w/ WASHERS) GALVINIZED OR ( I ( I DORMERFLAN. I /� 1�I STAINLESS STEEL WOOD SCREW 0 12" O,C. '1 ' N ' ' l�f""!' �l I DU 1), ATTACHING STRUCTURAL PANEL- FASTEN TO BUILDING w/ I�, - - - - - — - — - -— " - —- �" -— - —-— -— - � . 010x3" (w/ WASHERS) GALVINIZED OR STAINLESS STEEL 1 I WOODSC:REW +� 16" O.G, '- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - � PAGE : ALTERNATIVE FASTNER FOR SHUTTER TO BUILDING: 311011 31811 7' 8" 3'8" T 8" 3'8" 391011 010 TEE NUTS ATTACHED TO BLIDG. W/ VIOxl-1/2 ( W/ WASHERS) � o f MACHINE BOLT 0 12 O.C. 341011 FACE OF FOOTING 2x4 CONTINUOUS TABLE 1609,1.4 LATERAL BRACE AT 6' O.G. WIND-BORNE DEBRIS PROTECTION FASTENING SCHEDULE tRUSS OR CEILING JOIST FOR WOOD STRUCTURAL PANELS 2-10d NAILS GABLE END TRUSS FASTENER SPACING I 2 FEET 4 FEET Co FEET uu PANEL SPAN < PANEL. SPAN < PANEL SPAN < PANEL SPAN FASTENER TYPE < 2 FEET < 4 FEET < ro FEET < 8, FEET f" u' I I I I 2 1/2" Oro/ I, N ,I „� � � WOOD SCREWS 16 16 12 9 in Q O " =_3 " r n n n n ` NAILS WOOD SCREWS 16 16 16 12 H/3 BUT NEED NOT H 15d COOLER NAILS AT 10" O.G. a. THIS MEAN ROOF TABLE S EGN OF 33 FEET OR ON A MAXIMUM WLESPEED (3 SECOND GUST) OF 130 MPH AND EXCEED 40 FT. MAX. 2"x4" BLOCK NAILED TO EACH b. FASTENERS SHALL BE INSTALLED AT OPPOSING ENDS OF THE WOOD STRUCTURAL PANEL. I BRACE WITH 4-I0d NAILS �� c, NAILS SHALL BE IOd COMMON OR 12d BOX NAILS, H/2 BUT NEED NOT If EXCEED 15 FT, MAX. GYPSUM BOARD d. WHERE SCREWS ARE ATTACHED TO MASONRY OR MASONRY/STUCCO, THEY SHALL BE ATTACHED UTILIZING VIBRATION-RESISTANT ANCHORS HAVING A MINIMUM 5d COOLER NAILS AT l° D.C. WITHDRAWAL CAPACITY OF 490 POUNDS. 20 GAUGE SCRAP ai WOOD STRUCTURAL PANELS SMALL HAVE A MINIMUM THICKNESS OF 1116 INCH (11.1 m) o 10-Sd NAILS AND A MAXIMUM OF 8 FEET (2438 mm), f. PANELS SHALL BE PRECUT TO COVER THE GLAZED OPENINGS WITH ATTACHMENT I /� I HARDWARE PROVIDED. FOUNDATION CLEARANCE FROM SLOI=ES g. TABLE FROM SBCCI - 1999 EDITION, FIGURE R403,1,11 ENDWALL STUDS CGA5LE ENDWALL BRACING (WFCM FIGURE 3,6a) W a z EXTERIOR OR BEARING WALL TOP PLATES ENDWALL JOIST -c A A STUD NOTCH GREATER THAN ° '\\-5LOCKINC-r/ 50% OF THE PLATE WIDTH < 16d NAIL AT 24" O.G. GYPSUM BOARD tt '' ' BORED HOLE MAX1u DIAMETER 609a 16 GAGE (0.054 ) AND 1,5 WIDE OF STUD DEPTH METAL TIE ACROSS AND TO EACH SECTION A-A SIDE OF THE NOTCH WITH 8-16d X 5/8" MIN. TO EDGE NAILS EACH SIDE Q WOOD STRUCTURAL PANEL 5/8" MIN. TO EDGE INSTALLED IN ACCORDANCE l \0 r- co FLOOR BRACING AT END BAYS Sd NAIL AT 6" O.G. WITH NAILING SCHEDULE � NOTCH MUST NOT EXCEED TOP PLATES (ALL PANEL EDGES) r: (TABLE 3.1, WGFM HIGH WIND EDITION) 40% OF STUD DEPTH (WFCM FIGURE 3,6b) 8d NAIL AT 12" D.G. ON ALL FRAMING MEMBERS 'NOT AT IX m PIPE PANEL EDGES O �U )- (a) OUTSIDE CORNER DETAIL W BORED HOLES SHALL NOT 8d NAIL AT 4 O.C. BE LOCATED IN THE SAME Z eq CROSS SECTION OF CUT OR O C' NOTCH IN STUD TOE' PLATE FRAMING TO ACCOMMODATE �'I�'INC� GYPSUM BOARD � � Sd NAIL AT 6 O.G. m CALL PANEL EDGES) cq ND MAX. >1 L u—NOTCHING ,AND BORED HOLE LIMITATIONS NAILS BASED ON u- SHEAR WALL REQUIREMENTS FOR INTE I OjR NONBEAR ING WALLS WOOD STRUCTURAL PANEL Lu� R INSTALLED IN ACCORDANCE 16d NAIL AT 24" D.C. WITH NAILING SCHEDULE ENGINEER: (WFCM ISS5 SBC HIC- H WIND EDITION, 3,4,3,1,1) : -� (TABLE 3,1, WGFM HIGIH WIND EDITION) NO CEILINGJ CENTER 2x BLOCKING DIAPHRAGM ON SHEATHING JOINT Sd NAIL AT 6" O.C. ON ALL /����' "�- REQUIRED I YF'�'° T' RAFTERS AND CEILINGFRAMING I EDGES ANDEI4BO,G. ON AERS AT L L NEL JOISTS OR APPROVED -15/32 WOOD STRUCTURAL PANELS �. ON GABLE FACE AND ON WALL BELOWFRAMING ROOF TRUSS PEI- EMCa SEERS NOT AT BASED ON SHEARWALL REQUIREMENTS TOP PLATE TOP PLATE- (b) INSIDE CORNER DETAIL34 SECOND STORY SEE DRILLNG NOTCHING PROVISONS Gt 5LE ENDWALL, BALLOON FRAMING `w �'°'•:�p;„'°�'„�4,�1�';���"� EXTERIOR CORNER FRAMING - JOIST IS PERMITTED TO 'REFERRED METHOD JEFFREY T. BUTLER, P.E. BE CUT OR NOTCHED TOP PLATES FLOOR JOIST- BETWEEN THESE LIMITS WALL STUD- SEE DRILLING AND SEE DRILLING AN1D BOTTOM PLATE\., NOTCHING PROVISIONS NOTCHING PROVISIONS WFCM SECTION 3.3.1.1.1 I/3 SPAN 1/3 SPA WFCM SECTION 3,4,1,1.1 W JOIST ENDS TO BIE Z AlBLOCKED AGANIST uJ WALL 0 F O o SCUD O T ROTATION IN ACCORDANCE ROOF FRAMING DOUBLE TOP PLATE 4„ WALL 4" 11J WITH WFCM 3.3.1.3--END RESTRAINT W Q FOR BLOCKING AND 3.3.1,4 BRIDC31NG I R �^ u! } cv a BORED HOLE MAX BAND JOIST AND BRIDGING i/ DIAMETER 40'�o TOP PLATE TUa I OR BLOCKING SEE WFCM SECTION 3.3 I v! V OF SCUD DEP"tH BEARING RIPPLE S Ups -1 UD l TO RAFTER CONNECTION 21" CLEARANCE I 3O' (K oll z O 4 5/8" MIN. TO EDGE— WALL OR FLOOR TO FLOOR CONNECTION 24"' CLEARANCE % 3 1— 0 HEADER DEPENDING ON CONDITION, SEE IN FRONT OF Q W p „ MIN. TO EDGE A A DET LS ON SHEET 2 OF 2 THIS SET oPENiN� 5/8 W IY LAP JOIST 3 IN, MIN. LAVATORIES � BOTTOM PLATE WATER SHOWER v♦/J Q O NOTCH MUST NOT EXCEED BANOR D JOIST IIKING FULL LENGTH CLOSET 0 3 a 25% OF STUD DEPTH OR BIDET 0— HEADER SHALL NOT BE JOIST ; HEADER STUDS WALL STUDS 15„ WALL 15x WALL O LOCATED IN MIDDLE ONE-THIRD SILL PLATE O O r \ p OF STUD LENGTH • • NOTE: I � V � o _ IF HOLE IS BETWEEN 40% AND 60% CRAWL SPACE � p = S SUBFLDOR UPLIFT CONNECTION IS REQUIRED b / OF SCUD DEPTH, THEN STUD MUST BE BASEMENT --------------- OR _ ___ _-----__- AT EACH END OF HEADER AND BORED HOLE:i SHALL NOTJ • FOUNDATION i i i i i i AT BOTTOM OF HEADER STUDS IN DOUBLE AND NO MORE THAN TWO ; ; N�J�UPL1 ' BE LOCATED IN THE SAME SUCCESSIVE SCUDS ARE DOUBLED C INEC I I ADDITION TO CONNECTORS AT CROSS SECTION OF CUT OR AND SO BORED WALL STUDS AND AT TOP AND U o NOTCH IN STUD Rp2UIR BOTTOM OF CRIPPLES 21" CLEARANCE 21" CLEARANCE A I I I I I I I I A I I HINTERMEDIATE OLE NOTCH INCH AND BORED HOLE LIMITATIONS PLATFORM FRAMING BEARING WALL 1=0R EXTERIOR WALLS AND 5EAfiz INCH UJALL5 TYPICAL WALL, FLOOR AND IR001= FRAMING TYPICAL FRAMING AND UPLIFT PAGE * WATER CLOSETS (WFC:M ISS5 65C 14IG14 WIND EDITION, 3,4,LLD CONNECTIONS FOR OFENING6 FIGURE R3012 (0 MINIMUM FIXTURE CLEARANCES I ,i . i GENERAL NOTES: I p NAILING y� The design of this structure is based upon'the prescriptive approach using the 1.All work shall be performed in accordance with all state, (TABLE 3.6 WFCM HIGH WIND EDITION) 120 MILE I- ER HOUR ZONE - A ILI G LJ'CHEDULE Wood Frame Construction Manus), High Wind Edition (WFCM)published by The American Forest municipal,local zonimg and building codes and ordinances ROOF SHEATHING ATTACHMENT REQUIREMENTS FOR WIND LOADS and Paper Association. (1995)! having jurisdiction arid best standards of construction (120 MPH 3-SECOND GUST = 100 MPH FASTEST-MILE WIND SPEED IPER TABLE R3-1.2.1.3D Non-structural elements are based upon The New York State Residential Code-January 2003 practice. (TABLE 3.1, WFCM HIGH WIND EDITION) For the Climatic'and Geographical Design Criteria,see Table R301.2(1)on cover sheet. The American Institute of Architects Conditions shall apply STRUCTURAL SHEATHING MAXIMUM NAIL SPACING All non-engineered lumber to be Douglas Fir#2 or better SHEATHING LOCATION STUD SPACING ' Wind Limitations-Section R301.2.1 to all work performed on this project. OR PANEL SIDING FOR 8d COMMON NAILS o JOINT DESCRIPTION NUMBER OF NAILS NAIL SPACING Design Criteria-Section R301.2.1.1 (See Table R301.2.1.2 for Wind-Borne Debris Protection 2•The Contractor shall verify all conditions at the site. Any (SEE NOTE 1) (INCHES, O,C,) discrepancies must be brought to the attention of the Engineer (SEE NOTE 3) (INCHES, O.C.) Fastening Schedule For Wood Structural Panels) prior to commencerrnent of construction, The Contractor shall be E 6 (SEE NOTE 3) ' ROOF FRAMING Dead Load-Section R301.3 responsible for corrections not reported once he has started work 4' PERIMETER EDGE ZONE 16 0 Live Load-Section R301.4 F 6 (SEE NOTE 3) except for hidden jobs conditions. RAFTER TO TOP PLATE (TOE-NAILED) 4-Sd PER RAFTER Light and Ventilation-Section R303 3.Contractor shall guarantee to the Owner that all materials and E 6 Minimum Room Areas-Section R304 equipment incorporatted in the work will be new,and that all work INTERIOR ZONE 1(0 CEILING JOIST TO TOP PLATE (TOE-NAILIED) 4-8d PER JOIST Ceiling Height-Section R305 will be of good quali)y,free from faults and defects for a period F 12 (SEE NOTE 2) Sanitation-Section R306 of one year from the idate of the final Certificate of Occupancy. •, CEILING JOIST TO PARALLEL RAFTER (FACE-NAILED) 9-16d EACH LAP Toilet Bath and Shower Spaces-Section R307 4.The Engineer shall[not be responsible for the construction means, E 4 (SEE NOTE 4) 9-16d EACH LAP Glazing-Section R308 methods,techniques;,sequences or procedures,or for the safety GABLE ENDWALL RAKE AND RAKE TRUSS CEILING JOIST LAPS OVER PARTITIONS (FACE-NAILED) Garages and Carports-Section R309 precautions and protgrams in connection with the work,and he F 4 (SEE NOTE 4) Emergency Escape and Rescue Openings-Section R310 shall not be res onsiible for the contractors failure to out COLLAR TIE to RAF1r the work in accordance with the construction documents. The P EDGE R (FACE-NAILED) 6-8d PER TIE carry ry Exits-Section R311 E - NAIL SPACING AT PANEL S (iN,) •, 2-8d EACH END Landings-Section R312 Engineer shall not be:responsible for the acts or omissions by F = NAIL SPACING AT INTERMEDIATE SUPPORTS IN THE PANEL FIELD (IN,) BLOCKING 7o RAFTER (TOE-NAILED) Ramps-Section R313 the contractor. No clfianges shall be made in the documents •. RIM BOARD TO RAFTER (END-NAILED) 2-16d EACH END Stairways-Section R314 and/or the building ws designed without the expressed written I. FOR ROOF SHEATHING WITHIN 4 FEET OF THE PERIMETER EDGE OF THE ROOF, INCLUDING 4 FEET ON EACH 'o Handrails-Section R315 consent of the Engineer. SiDE OF THE ROOF PEAK, THE 4 FOOT PERIMETER EDGE ZONE ATTACHMENT REQUIREMENTS SHALL BE USED, ° WALL FRAMING Guards-Section R316 5.The contractor and all subcontractors shall maintain continuous ' o Smoke Alarms-Section R317 Insurance coverage!including statutory policies Worker '• Simpson Strong-Tie TOP PLATE TO TOP PLATE (FACE-NAILED) 2-16d (SEE NOTE 1) PER FOOL 9 9 ry ( 2. TABULATED 12 fNCI-I O.G. NAIL SPACING ASSUMES SHEATHING ATTACHED t0 RAFTER/TRUSS FRAMING o, Foam Plastic-Section R318 Compensation,etc.)land general liability in an mount not " Flame Spread and Smoke-Section R319 less that$5 million amd automobile liabilityand damage MEMBERS WITH G30.49. FOR FRAMING MEMBERS WITH 0,42ZGt0,49, THE NAIL SPACINGS SHALL BE �o MtS30G OR GS16 1� 4-16d JOINTS - EACH SIDE Insulation-Section R320 o COILED STRAP TOP PLATES AT INTERSECTIONS (FACE-iNAILED) g REDUCED t0 6 INCHES O.G. coverage not less than$2 million. The Engineer shall be •oo STUD t0 STUD (FACE-NAILED) 2-16d 24" O,C, Dwelling Unit Separation-Section R321 a named insured on.any and all policies. AT EACH ROOF RAFTER Moisture Vapor Retarders-Section R322 6. Provide 0.025"alwminum termite shields over fibrous 3, TABULATED (o INCH O.C. NAIL SPACING ASSUMES SHEATHING ATTACHED TO RAFTER/TRUSS FRAMING USE 8-16d NAILS AT HEADER TO HEADER (FACE-NAILED) trod 16" O.C. ALONG EDGES Protection Against Decay-Section R323 insulation at all perinmeter sills. MEMBERS WITH G30,49, FOR FRAMING MEMBERS WITH 0,42(GV0.49, THE NAIL SPACINGS SHALL BE Protection Against Termites-Section R324 7.All wood in contactt with concrete or masonry to be Wolmanized REDUCED TO 4 INCHES O.C. EACH END TOP OR BOTTOM PLATE t0 STUD (ENDS-NAILED) 2-lbd PER 2x4 STUD Site Address-Section R325 or pressure creosoted. o Accessibility-Section R326 8.A single station snnoke detector alarm device shall be installed 4. TABULATED 4 INCH O.C. NAIL SPACING ASSUMES SHEATHING ATTACHED TO RAFTER/TRUSS FRAMING STUD T O ROOF ��1=T1� 3-16d Flood Resistant Construction-Section R327 PER 2x6 STUD in each bedroom,on all floors and shall be all interconnected per code. P MEMBERS WITH G30AS. FOR FRAMING MEMBERS WITH 0.47GZ0.49, THE NAIL SPACINGS SHALL BE 4-16d PER 2x8 STUD 9.All bathrooms withroui operable windows to be mechanically ventilated Foundations-Chapter 4 as per New York Statte Code. REDUCED t0 3 INCHES O.C. BOTTOM PLATE TO FLOOR JOIST, 13ANt>JOIST, ENDJOIST OR BLOCKING (FACE-NAILED) 2-trod (SEE NOTE 1,2) PER FOOT Design based upon presumptive load bearing values of sandy gravel and/or gravel at 3000 pounds 10.Heating to be de:signed to provide 70 degrees F.with outdoor CONNECTION per square foot. Contractor to consult Engineer if different soil materials are found upon excavation, Simpson Strong-Tie FLOOR FRAMING or test hole,for alternative footing and foundation wall design. designed air-temperature of 0 degrees F.and 15 MPH wind. GS16 114"COILED STRAP - 11.All electrical worlds to be in accordance to the rules and JOIST t0 SILL, TOP PLATE OR GIRDER (TOE-NAILED) 4-Sd PER JOIST regulations of the N`Y.B.F.U.and a N.Y.B.F.U.certificate is 16" O.G. USE 4-8d NAILS Foundation Notes: to be presented to thre Owner at the completion of the job. AT EACH STUD, WRAP 2-Sd EACH END '/_"Anchor Bolts(SSTB 28)See chart on this sheet for spacing 12.Plumbing Installation to comply with State and Local codes r4411 BRIDGING t0 JOIST (TOE-NAILED) 8"poured concrete foundation wall,8'0"high,3000#test UNDER SILL PLATE BLOCKING TO JOIST (TOE-NAILED) Minimum depth-Section 403.1.4,48"minimum coverage to top of footing and the sewage disposal system to meet Health Department standards. 2-Sd EACH END 13.Do not scale drawvings. Use figure dimensions only. MIN OVERLAP iS 12" ' 16"x 8"poured concrete wall footings,3000#test 14.All work to conforrm to the rules and regulations of the New York ' BLOCKING TO SILL OR TOP PLATE 0101E NAILED) 3-16d EACH BLOCK 2-1 %"x 11 7/8"Microlam Girder(or 3 Y?x 11 7/8"Power Beam) Energy Conservatiom Construction Code. All lazed area to be double 0 NOTE: 4"poured concrete floor slab with 6x6x#10 mesh and vapor barrier gY g STRAPS MAY BE p P Po lazed and all extericor doors to have insulated cores. . t0000. ® '. LEDGER STRIP TO BEAM (PACE 3-16d EACH JOIST Damp proofing at exterior foundation below grade-Section R406 g ' PLACED EITHER 15.The Insulation prrotection as indicated on these plans exceeds 030"x 30"x 12"deep poured concrete column footings,3000#test the Code's minimum i standards. UNDER OR OVER JOIST ON LEDGER t0 BEAM (tOE-NAILED) 3-8d PER JOIST Deck and porch footings as noted,3000#test,48"minimum buried depth • SHEATHING 16.These drawingsand specifications are instruments of service and 3-16d PER JOIST Foundation wall to extend a minimum of 8"above finished grade shall remain the property of the Engineer whether the project for 'BAND JOIST t0 JOIST (END-NAILED) All footings to be carried down to undisturbed soil , 00which they are made!is executed or not. They may not be used �No footing shall be set higher than a 30 degree angle from any other footing BAND JOIST TO SiLL OR TOP PLATE (T(OE-NAILED) 2-16d (SEE NOTE 1) PER FOOT on anyother project except bywritten authorization of the Engineer.Pour no concrete on frozen ground or In freezing weather 17.The engineer ha s not been retained for site supervision,on-site 0 �p ROOF SHEATHING Provide 3 all steel rally columns inspections and certiifications as required or requested by the owner, Backfill shall not be placed against the wall until the wall has sufficient strength and has been contractor or local buiflding department. ' . • , o' STRUCTURAL PANELS ad (SEE TABLE 3.8) anchored to the floor above,or has been sufficiently braced to prevent damage • • , by the backfill(Section R404.1.7) UPLIFT-CONTINUOUS PATH CONNECTORS . m DIAGONAL BOARD SHEATHING 2-Sd PER SUPPORT Floors-WFCM Prescriptive Method USE SIMPSON STWONG-TIE CONNECTORS 1"x6" OR I"x8" Floor framing shall be nailed in accordance with Table 3.1 WFCM HIGH WIND EDITION FOLLOW PRODUCTr SELECTION GUIDE AND I"xt0" OR WIDER 3-ed PER SUPPORT Draftstopping-Section R502.12 INSTALLATION MANUAL FOR HIGH WIND RESISTANT • ' Fireblocking-Section R502.13 CONSTRUCTION CATALOG C-HW02 0 , CEILING SHEATHING Floor Construction: 0 ' ' e _ • ANCHOR BOLTS IN I FOUNDATION USE: " t GYPSUM WALLBOARD 5d COOLERS 'I" EDGE / loll FIELD YA"OSB plywood subfloor,fasten per Table 3.1 WFCM SSTB28 WITH BEARING PLATE,SEE FOUNDATION . ' ' � 11-1 Floorjoists:See Foundation and Floor Plans,spacing as noted NOTES FOR SPACING 00 , ' Simpson Strong-Tie WALL SHEATHING Fasten per Table 3.1 WFCM 2-2x6 CCA sill with termite shield and sill seal SILL PLATE TO RIM[JOIST USE: 0 0 C516 11'4" COILED STRAP - r STRUCTURAL PANELS ad (SEE TABLE 3.9) Finish floors per agreement " T 16 D.G. USE 4-8d NAILS cv P 9 LTP4 16 O.C.AT EXTERIOR PERIMETER AND GARAGEIHOU)SE COMMON WALL ' � I AT EACH STUD n j r FIREBOARD PANELS Wall Construction-WFCM Prescriptive Method USE 4 8d NAILS AT'EACH END 00 " �/ -� rod 3" EDGE / 6" FIELD Wall framing and finishing shall be nailed and or screwed in accordance with 00 MiN OVERLAP IS 2-f CA 7/16° �� Table 3.1 WFCM GARAGE STUD TO GARAGE SILL PLATE USE: i FLOOR TO FLOOR CONNECTIONS. r `' UJ CO 25/32" ad 3 G FDE / 6 FIELD 1x6 Pine fascia,wrap SSP CONNECTOR AT 16 O.C. -- �� �� Overhangs as noted USE 4 8d NAILS AT EACH END /�T t t�,� t-� 01 X GYPSUM WALLBOARD Sd COOLERS EDGE / 10 FIELD Vinyl vented soffits SILL PLATE I O RIM 1 JOIST1�1.� ad (SEE TABLE 3,S) Aluminum gutters and leaders RIM JOIST TO STUCD CONNECTION USE: Z U_ HARDBOARD Siding:See Elevations MTS 12, 16"O.C. X PARTICLEBOARD PANELS 8d (SEE TABLE 3.9) Tyvek housewrap USE 4 8d NAILS AT'EACH END RIM i JOIST TO STUD CONNECTION Y2"OSB sheathing,see fastening schedule,Table 3.1 WFCM �Q Q DIAGONAL BOARD :SHEATHING 2x4 Studs @ 16"o.c.with 2x4 shoe and double 2x4 plate FLOOR TO FLOOR iCONNECTION USE: ♦ 3 0 ill %2"Gypsum wall board MSTA 36, 16"O.C. III 1"x6" OR I"x8'° 2-Sd PER SUPPORT 5/8 Type X GWB in garage USE 4 8d NAILS AT EACH END p g Simpson Strong-Tie " 1/2" SPACING BLOCKING AT %?MR GWB in wet areas FOR CANTILEVER(CONDITION USE MTS12, 16"O.C. C516 144 COILED -� „ r I"x1o" OR WIDER 3-8d PER SUPPORT At least one window in each sleeping room shall comply with the exit requirements of section R310 USE 4 8d NAILS AT I EACH END STRAP WIN MIN 12" ALLOWS o 24 O.C. ALLOWS 3 Note drilling and notching limitations In figure R602.6(1)for bearing walls HOLDDOWN N FLOOR SHEATHING and figure R602.6(2)for non-bearing walls. RAFTER TO STUD(CONNECTION USE: OVERLAP AT EACH HOLDDOWN 7 Follow exterior corner framingdetail figure R602.10.5 STUD INSTALLATION SIDEWALL INSTALLATION n/ STRUCTURAL PANELSS g MTS 12,EACH ROQ)F RAFTER p USE 816d NAILS ATi EACH END i" OR LESS ad 6" EDGE / 12" FIELD ' Roof Assemblies-WFCM Prescriptive Method Asphalt strip shingles shall have a minimum of six(6)fasteners per shingle(section R905.6) RAFTER TO RIDGE:TO RAFTER CONNECTION USE: o U_ GREATER THAN I �� 10d 6" EDGE / 6" FIELD Underayment application(Section R905.2.7) CS20 USE 8-8d NAILS IN EACH END ENDWALL UJ For roof slopes of two(2)units vertical in twelve(12)units horizontal(17-percent slope), AT EACH ROOF RAFTER DIAGONAL BOARD SHEATHING up to four(4)units vertical in twelve(12)units horizontal(33-percent slope),undedayment ' (PHD DOWN o o CORNER STUD 0 � 2-Sd PER SUPPORT shall be two(2)layers applied in the following manner.Apply a 19-inch (483 mm)strip of DECK POST TO CONCRETE CONNECTION USE: o 1"xro" OR 1"x8"' underayment felt parallel with and starting at the eaves,fastened sufficiently to hold in place. PBS44A FOR EACH POST-USE 14-16d NAILS CONNECTED TO ENGINEER: Starting at the eave,apply 36-inch-wide(914 mm)sheets of undedayment,overlapping 0 TRANSFER SHEAR o 1"x10" OR WIG ER 3-ad PER SUPPORT successive sheets 19 inches 483 mm ,and fastened sufficient) to hold in lace. ! ( ) Y P DECK POST TO GIRDER CONNECTION USE: 2-16d COMMON For roof slopes of four(4)units vertical in twelve(12)units PC44 FOR EACH POST 1,NAILING REQUIREMENTS ARE BASED ON WALL SWEATHING NAILED 6" ON-CENTER AT THE PANEL EDGE, IF WALL SHEATHING 18 NAILED 3"ON-CENTER AT THE PANEL EDGE TO oetAlN HIGHER SHEAR CAPACITIES,NAILING REEQUIREMENTS FOR STRUCTURAL MEMBERS SHALL BE DOUBLED,OR ALTERNATE CONNECTORS,SUCH AS SHEAR PLATER, O ° HOLDDDWN NAILS AT loll D.G. SHALL AI USED to MAINTAIN THE LOAD PATH. Ice Protection(Section R 905.2.7.1) GIRDER TO DECK JOIST CONNECTION USE: (PHD5) o Underlayment In High wind(Section R 905.2.7.2) MTS12 @ EACH JOIIST ® ® CORNER STUD MITT to BE REDUCED to 1-16d NAIL PER Foot. Flashing(Section R 905.2.8) ; �_� S THE TABULATED NUMBER OF"LS SHALL BE PERMITTED -2-16d COMMON G IS CONTINUOUS OVER COrNNECtED MEMBER E 2, WHEN WALL SHEATHING „ CONNECTED TO d ra !J-, =dr Chimney's and Firespaces-Chapter 10 GIRDER TO DECK,JOIST CONNECTION USE: O NAILS AT 6 O.C, ° Energy Efficiency-Chapter 11,see attached report MTS12 @ EACH JOIST TRANSFER SHEAR (TABLE 3.S WFCM HIGH WiND EDITION) Mechanical-Chapter 12 tqi �a WALL SHEATHING A'�TTACHMENT REQUIREMENTS FOR WIND LOADS General Mechanical Systems-Chapter 13 PORCH POST TO D c%,.v USE: FLOOR TO FLOOR CONNECTIONS-. (120 MPH 3-:SECOND GUST ■ 100 MPH FASTEST-MILE WIND SPEED (PER TABLE R3-1.2.1.3ll Heating and Cooling Equipment-Chapter 14 2-AC4 -USE 14-116d NAILS Exhaust Systems-Chapter 15 CANTILEVER CONDITION Duct Systems-Chapter 16 PORCH POST TO GIRDER USE:2-AC4 D SHEATHING LOCATION STUD SPA(CiNG STRUCTURAL SHEATHING MAXIMUM NAIL SPACING Combustion Air-Chapter 17 USE 14-16d NAILS( JEFFREY T. BUTLER, P.E. (SEE NOTE 1) (INCHES, O,.C.) OR PANEL SIDING FOR 8d COMMON NAILS Chimneys and Vents-Chapter 18 (SEE NOTE 3) (INCHES, O.C,) Plumbing-PartVll 9 PORCH ROOF RAFTER TO GIRDER USE: 1 3/4" MINIMUM E 6 MTS 12 AT EACH ROOF RAFTER BP Simpson Strong-Tie EDGE DISTANCE 4' EDGE ZONE 16 m F 12 (SEE NOTE 2) H-2.5 CLiPs ® 16" o.c. HOLD DOWN BRACKETS AT SHEAR WALL CORNERS, W d) � INTERIOR ZONE 16 E 6 USE 9-Sd NAILS Z z F 12 AT EACH STUD ,'4ND U11NDC�UJ �4ND DOOR OPENINGS �Z z o E - NAIL SPACING AT PANEL EDGES (IiN,) (WFCM I FIGURE 3,1a 4 4. I V) W cal ~ Q F * NAIL SPACING AT INTERMEDIATE SUPPORTS IN THE PANEL FIELD (IN.) Simpson Strong-Tie W > c4 F H CORNERS, THE 4 FOOT EDGE ZONE ATTACHMENT U210 2X6 411 RIDGE TENSION SCRAP W Q Q >- N °z I, FOR WALL SHEATHING WITHIN 4 FEET n THE REQUIREMENTS SHALL BE USED. AT EACH RAFTER � a AC�eon Strong-Tie CS20 USE 8-86 NAILS (Y Z ' a 4-lOd x 1 1/2° iN EACH END AT W O Q Is '4 AT EACH POST EACH ROOF RAFTER 3 Z 2. TABULATED 12 INCH O.C. NAIL SPACING ASSUMES SHEATHING ATTACHED To STUD FRAMING 4. 0 ~ _W MEMBERS WiTH G20AS, FOR FRAMING MEMBERS WITH 0.421GS0.4% THE NAIL SPACINGS SHALL NOTE: W BE REDUCED TO ro INCHES O,G, r ATTACH LEDGER TO FRAMING MEMBER WITH 2-1/2" X 5" LAG SEE PLAN 3, FOR EXTERIOR PANEL SIDING, GALVANIZED BOX NAILS SHALL BE PERMITTED TO BE SUBSTITUTED � � BOLTS AT 16" ON CENTER D FOR COMMON NAILS. D D C ° C ° RAFTER O 'A Q `p F1 Q 'p Q 'p Simpson Strong-Tie OC d o (TABLE 3.2A WFCM HiGH WIND EDITION) �D '� ��D '� D ' D '> U210 2X6 O Z SILL OR BOTTOM PLATE TO FOUNDATION ANCHOR BOLT CONNECTIONS RESISTING LATERAL 4 SHEAR LOADS 4 ° C �� 4 ° 4 ° a ° AT EACH CEILING JOIST c z 4-10d x 1 1/2" MAXIMUM ANCHOR MAXIMUM ANCHOR = > D RIDGE BEA p a W FOUNDATION BRACING WALL PERIMETER , 0 n �� � . � 4 . � 4 � � � � ° a � JOIST HANGER REQUIRED U � Q ANCHOR BOLT GONNECTIOIJ SUPPORTING EDGE NAIL SPACING (IN,) BOLL SPACING (iN.) BOLT SPACING (IN.) ° t1 At CACHE ORAL CEILINGS (1/2" ANCHOR BOLTS) (5/8" ANCHOR BOLTS) o D o D LSSU OR EQUAL ° 4 0,/ 4 ° C ° 4 ° 4 SILL PLATE TO FOUNDATION I STORY 46 S < <1 <I <1 a Simpson Strong-Tie G RIDGE n nn ^^ a (CRAWL SPACE OR BASEMENT) 2 STORIES ALL 23 36 `' `� G' `� Z' `0 ° D U210 2X6 AT EACH DECK/PORCH JOIST 2" MINIMUM TENSION-STRAP ° SIDECOVER >s;�. DETAIL 3 STORIES 15 23 D � ° D _ � ° D ,0 . '" 4-lOd x 11/2" / .�•• PAGE : WALL. TO a° 4° Sim eon Strong-Tie Tie Simpson Strong-Tie WALL BOTTOM PLATS= TO FOUNDATION 3 19 28 <i <� p g PBS44 (SLAB-ON-GRADE) I-3 STORIES 6 57 FOUNDATION � '� �° ° D TYPICAL FORCH/DECK 6ST528 WITH BP � AT EACH POST FOOTING � O� NOTE: MAX 12" FROM EACH CORNER AND EACH SPLICE, PROVIDE BEARING PLATE BY SIMPSON, SEE DETAIL CONNECTIONS D LEDGER CONNECTIONS ANCHOR BOLT DETAIL PORCH COLUMN CONNECTIONS