Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
33117-Z
FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-33211 Date: 08/11/08 THIS CERTIFIES that the building ADDITION Location of Property: 1260 NORTH BAYVIEW RD EXT SOUTHOLD (HOUSE NO.) (STREET) (HAMLET) County Tax Map No. 473889 Section 70 Block 12 Lot 32 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated JUNE 1, 2007 pursuant to which Building Permit No. 33117-Z dated JUNE 7, 2007 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is SCREENED PORCH ADDITION TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR AS PER ZBA #6022, DATED 5/10/77. The certificate is issued to LINDA D BERTANI (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A ELECTRICAL CERTIFICATE NO. 4006084 07/15/08 PLUMBERS CERTIFICATION DATED N/A ut oriz d Signature Rev. 1/81 Form No.6 TOWN OF'SOUTHOLD BUILDING DEPARTMENT TOWN HALL 1 AUG,_ 7 2Q0J 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY Tots`-i'' (0 FAG'UTH O LD This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features: 2_ Final Approval from Health Dept of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters_ 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9,1957)non-conforming uses,or.-buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building_and-unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of.Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the,applicant, C. Fees 1. Certificate of Occupancy-New dwelling$25.00,Additions to dwelling$25.00,Alterations to dwelling$25.00, Swimming pool$25.00,Accessory building$25-00,Additions to acessdry building$25.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 S. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 Date. O(A -7 New Construction: Old or Pre-existing Building: (check one) Location of Property: OCOCA-J W N v-(, 'fox-L f 1,a id-- House No. Street Hamlet LOwner or Owners of Property: _ V�cc A-C n-, Suffolk County Tax Map No 1000,Section Q Block Z Lot Z Subdivision Filed Map. 'n Lot: Pennit No. 33 Date of Permit_ (0 '7 O Applicant: Health Dept.Approval: Underwriters Approval-- Planning Board Approval: / Request for: Temporary Certificate Final Certificate: ✓ {check one) .. Fee Submitted: $ CQ 1 d4z) 2-21;31�)4 t All� j Applicant Signature o �Is��I ( ��I:fi! = ��rstn1_nt�����r���t��lsl:n��l_n���������Ist��I:n�����I�I������Is o0 5 BY THIS CERTIFICATE OF COMPLIANCE THE 5 5 NEW YORK BOARD OF FIRE UNDERWRITERS 5 5 S 5 BUREAU OF ELECTRICITY 5 5 40 FULTON STREET — NEW YORK, NY 10038 c� 5 CERTIFIES THAT 5 5 5 C5, Upon the application of upon ,premises owned by 5 5 5 5 5 G&S ELECTRICAL CONTR. JOHN BERTANI 5 P.O. BOX 215 1380 OAKWOOD DR 5 SOUTHOLD, NY 11971, SOUTHOLD, NY 11971 5 5 Located at 1380 OAKWOOD DR SOUTHOLD, NY 11971 c� 5APPlication Number: 4006084 Certificate Number: 4006084 C5 c5 5 Section: Block: Lot: Building Permit: * BDC: S 5 ns11 5 Described as a Residential occupancy, wherein the premises electrical system consisting of 5 electrical devices and wiring, described below, located in/on the premises at: 5 First Floor,sun room, 5: 5 5 5 A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed 5 5 herein, was conducted in accordance with the requirements of the applicable code and/or standard 5 promulgated by the State of New York, Department of State Code Enforcement and. Administration, or other 5 authority having jurisdiction, and found to be in compliance therewith on the 15tn Day of July, Zoos. 5 Name QY Rate Rating Circuits Type 5 Wiring And Devices CJJJ 5 Fixture 6 0 Incandescent 5 5 Outlet 4 0 Gen,Purpose 5 Outlet 6 0 Fixture 5 Paddle Fan 1 0 5 5 Receptacle 1 0 GFCI 5 5 Receptacle 2 0 Gen,Purpose 5 Switch 2 0 Gen,Purpose 5 5 5 5 5 5 5 S 5 sea/ 5 5 1 of 5 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. S 5 5 IN ��RPM 2PR�RP���0111 ���LPL��E-!lI I ������LPLP�L� o FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 33117 Z Date JUNE 7, 2007 Permission is hereby granted to: LINDA D BERTANI 1380 OAKWOOD DR SOUTHOLD,NY 11971 for SCREENED PORCH ADDITION PER ZBA DECISION #6022 AS APPLIED FOR at premises located at 1260 NORTH BAYVIEW RD EXT SOUTHOLD County Tax Map No. 473889 Section 070 Block 0012 Lot No. 032 pursuant to application dated JUNE 1, 2007 and approved by the Building Inspector to expire on DECEMBER 7, 2008 . Fee $ 200 . 00 Authorized Signature ORIGINAL Rev. 5/8/02 TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING hPARTMENT Do you have or need the following,before applying? TOWN 14ALL Board of Health SOUTHOLD,NY 11971 3 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey PERMIT NO. "23 17 Z:::� Check Septic Form N.Y.S.D,E.C. Trustees Examined ,20_qL Contact: Approved &L 12007 Mail to: Disapproved a/c A--Tlll�„ Phone: Expiration �� ,20Ar Kl_ --_ N R I_.�, Building Inspector r - t" I i APPLICATION FOR BUILDING PERMIT , r � I t Date Ids 72004 _- ` ' INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans, accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied.or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name,if a corporation) ail' addres����cant) 1 State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder Name of owner of premises (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: 111 0 414?KWe01::!1 ���y� �d 0*0//9 House Number Street Hamlet County Tax Map No. 1000 Section 70 Block ���«.�U -:Lot' Subdivision Filed Map No::----�` ; -Lot (Name) .l ; 2. State existing use and occupancy of premises and intended use and occupancy of proposed constructim: a. Existing use and occupancy �yy�i� �rr�C�LG�,cp� b. Intended use and occupancy 1_9A",/ 3. Nature of work.(check which applicable): New Building Addition &Z Alteration Repair Removal Demolition Other Work (Description) 4. Estimated Cost ;?o 0" Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor- . If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use... 7. Dimensions of existing structures, if any: Front Rear �� Depth 3 3 Height �-,' Number of Stories 2 Dimensions of same structure with alterations or additions: Front �� r Rear Depth 41 f ` Height 5,64( Number of Stories o� 8. Dimensions of entire new construction: Front /7 Rear /7 Depth Height eI Number of Stories 9. Size of lot: Front //6 c Rear C'1(, ! 7 Depth 10. Date of Purchase /79 Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded?YES NO d/Will excess fill be removed from premises? YES NO 14.Names of Owner of premises i3&w7~Address 1�3X-b one No. Ii61 , Name of Architect Address Phone No 477-osLD� Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTY OF So f-FoLUZ) &652e7,VXf1 being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)He is the y l_o yl r-V— (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief, and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me thi da of (W12,Lj_ _.20C� Votary Public Signature of Applicant . LYNDA M BOHN NOTARY PUBLIC,State of New York N0.01 B0602I20�ty Term Expires March 8, OF S0Uly0 courm,��' TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] IN ATION [ ] FRAMING / STRAPPING [ FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: DATE INSPECTOR FIELD INSPECTION REPORT DATE I COMMENTS � ro FOUNDATION(IST) J a ------------------------------------- kD d � FOUNDATION(2ND) Jz- z 0 . o ROUGH FRAMING& y PLUMBING INSULATION PER N.Y. -- y STATE ENERGY CODE r FINAL ADDITIONAL COMMENTS 2r CO C Z m .J G �C' O z E� y x d b y APPEALS BOARD MEMBERS OF $I�(/r Mailing,Address: James Dinizio,Jr., Chairman �� yp Southold Town Hall 't0 l4 53095 Main Road• P.O. Box 1179 Gerard P. Goehringer Southold,NY 1 197 1-0959 Ruth D. Oliva Office Location: Michael A. Simon . .... Town Annex/First Floor,North Fork Bank Leslie Kanes Weisman I�cou 54375 Main Road(at Youngs Avenue) Southold,NY 11971 http://southoldtown.northfork.net n n; I) GS, ZONING BOARD OF APPEALS TOWN OF SOUTHOLD i�1 AY ! 2Tel. (631) 765-1809•Fax(631) 765.9064 DELIBERATIONS AND DETERMINATION MEETING OF MAY 10, 2007 ZB File No. 6022— Linda D. Bertani. Property Location: 1380 Oakwood Drive, Southold CTM 70-12-32 SEQRA DETERMINATION: The Zoning Board of Appeals.has visited the property under consideration in this application and determines that this review falls under.the Type II category.of the State's List of Actions, without further steps under SEQRA. PROPERTY FACTS/DESCRIPTION: The applicant's 30,492 square foot non-conforming parcel in an R- 40 District at Goose Creek with 110 feet along Oakwood Drive and 275 feet along North Bayview Road. The property is improved with an existing two-story,.single-family dwelling, as shown on the June 9, 1986 survey amended February 2, 2007, by John Metzger(Peconic Surveyors, P.C.). BASIS OF APPLICATION: Request for a Variance under Sections 280422A and 280-124, based on applicant's January 22, 2007 application requesting a building permit to construct a porch addition and the Building Inspector's Notice of Disapproval stating that the new addition will constitute an increase in the degree of nonconformance under Zoning Code Interpretation #5039 (Walz) when constructed less than 40 feet from the front lot line at North Bayview Road. SUFFOLK COUNTY ADMINISTRATIVE CODE: This application has been referred as required under the Suffolk County .Administrative Code Sections A 14-14 to 23, and the Suffolk County Department of Planning reply dated April 5, 2007 states that the application'is considered a matter for local determination as there appears to be no significant county-wide or inter-community impact. TOWN CODE CHAPTER 268 -LWRP DETERMINATION: The proposed porch addition, replacing an existing deck, is greater than 100 feet from Goose Creek as shown on the February 2, 2007 revised survey and is determined exempt under Chapter 268. FINDINGS OF FACT The Zoning Board of Appeals held a public hearing on this application on April 26, 2007, at which time written and oral evidence were presented. Based upon all testimony, documentation, personal inspection of the property, and other evidence,the Zoning Board finds the following facts to be true and relevant: AREA VARIANCE RELIEF REQUESTED: Owner/applicant proposes to add two exterior walls and a roof to their existing dwelling to create an enclosed 'three-season, one=story addition with a 17' x 14'T floor deck over a raised patio/deck existing at the rear of the home adjacent to the front yard of North Bayview Road. Page 2—May 10,2007 ZB File No. 6022-Linda D. Bertani CTM No.70-12-32 REASONS FOR BOARD ACTION: On the basis of testimony, presented, materials submitted and personal inspections, the Board makes the following findings: 1. Grant of the variance will not produce an undesirable change in the character of the neighborhood or a detriment to nearby properties. The applicant proposes a screened porch addition to replace a patio that exists at the south side of the home. The porch will contain electricity but without not contain plumbing or heating because use will be during the three seasons of the year that will not require heat. The porch will be built over the existing raised deck without any extension beyond the house. 2. The benefit sought by the applicant cannot be achieved by some method, feasible for the applicant to pursue, other than an area variance. The proposed addition will occupy the place of the existing raised deck, maintaining and preserving the existing 36-foot nonconforming setback. 3. The variance granted herein is not substantial. The dwelling will maintain the same nonconforming front yard setback, and the porch will not extend past the first floor of the existing house. 4. The difficulty has not been self-created. It is a result of the fact that the property is a corner lot and must meet two code-required front-yard setback requirements. 5. No evidence has been submitted to suggest that a variance in this residential community will have an adverse impact on the physical or environmental conditions in the neighborhood. 6. Grant of the requested relief is the minimum action necessary and adequate to enable the applicant to enjoy the benefit of a screened porch, while preserving and protecting the character of the neighborhood and the health, safety and welfare of the community. RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing test under New York Town Law 267-B, motion was offered by Member Simon, seconded by Member Goehringer, and duly carried, to GRANT the variance as applied for, as shown on the 6/9/2006 survey, amended 2/2/2007 by John Metzger, and the 3/30/2006 Elevation/Floor Plan #2747 prepared by John Rabkevick/Penny Lumber. I Any deviation from the variance given such as extensions, or demolitions which are not shown on the applicant's diagrams or survey site maps, are not authorized under this application's when involving nonconformities under the zoning code. This action does not authorize or condone any current or;future use, setback or other feature of the subject property that may violate the Zoning Code, other than such uses, setbacks and other features as are expressly addressed in this action. The Board reserves the right to substitute a similar design that is de minimis in/nature for an alteration that does not increase the degree of nonconformity. Vote of the Board: Ayes: Members Dini ' (Chairma , Oliv , Goehringer, Simon, and Weisman. This Resolution was duly adopted (5-0). r roes Dinizio Jr., Chairma 5 f°7 /2007 Approved for Filing I JAMES J. DEERKOSKI, P.E. 260 Deer Drive Mattituck, N.Y. 11952 (631) 298-7116 Date: August 7, 2008 To: Town of Southold Building Dept. Re: Strapping/Framing Inaspection f'� �' 20L6 Linda Bertani - 1380 Oakwood Dr. Southold, NY 11971 Permit# 33117Z To Whom It May Concern: This letter certifies that all wind strapping on the above mentioned project is in tact, and meets all state and local building codes. A Framing Inspection was also Performed on this Structure, and all framing was done correctly and also meets all state and local building codes. Any questions please feel free to call. �{F e� y 0 Sincerely iji!tl;N PJ1� Jame Deerkoski P.E. 4072,5 �` . NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION DEC PERMIT NUMBER EFFECTIVE DATE 1-4738-03544/00001 January 5,2006 FACILITY/PROGRAM NUMBER(S) PERMIT EXPIRATION DATE(S) a• Under the Environmental January 4,2011 Conservation Law TYPE OF PERMIT■New ❑Renewal❑Modification❑Permit to Construct ❑Permit to Operate ❑ Article 15,Title 5:Protection of Waters ❑ Article 17,Titles 7,8:SPDES ❑ Article 27,Title 9; 6NYCRR 373: Hazardous Waste Management ❑ Article 15,Title 15:Water Supply ❑ Article 19:Air Pollution Control ❑ Article 34:Coastal Erosion ❑ Article 15,Title 15:Water Transport ❑ Article 23,Title 27:Mined Land Management Reclamation ❑ Article 15,Title 15:Long Island Wells ❑ Article 36:Floddplain Management ❑Article 24: Freshwater Wetlands ❑Article 15,Title 27: Wild,Scenic and ❑ Articles 1,3, 17,19, 27,37;6NYCRR Recreational Rivers ■ Article 25:Tidal Wetlands 380:Radiation Control ❑ 6NYCRR 608:Water Quality Certifica- ❑ Article 27,Title 7; 6NYCRR 360: tion Solid Waste Management PERMIT ISSUED TO TELEPHONE NUMBER Linda D. Bertani (631)765-1594 ADDRESS OF PERMITTEE 1380 Oakwood Drive, Southold, NY 11971 CONTACT PERSON FOR PERMITTED WORK TELEPHONE NUMBER NAME AND ADDRESS OF PROJECT/FACILITY Bertani property, 1380 Oakwood Drive, Southold COUNTY TOWN WATERCOURSE NYTM COORDINATES Suffolk Southold Goose Creek DESCRIPTION OF AUTHORIZED ACTIVITY: Construct an 1 V x 17'screened porch. All work must be done in accordance with the attached plans stamped NYSDEC approved on 1/05/06. By acceptance of this permit,the permittee agrees that the permit is contingent upon strict compliance with the ECL, all applicable regulations,the General Conditions specified (see page 2&3) and any Special Conditions included as part of this permit. PERMIT ADMINISTRATOR: ADDRESS George W. Hammarth (DMG) Region 1 Headquarters, Bldg.#40, SUNY, Stony Brook, NY 11790-2356 AUTHORIZED SIGNAT E DATE Page 1 of 4 Janua 5, 2006 NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION SPECIAL CONDITIONS 1. During construction, concrete or leachate shall not escape or be discharged, nor shall washings from transit mix trucks, mixers,or other devices enter tidal wetlands and or protected buffer areas. 2. Any debris or excess material from construction of this project shall be completely removed from the adjacent area (upland)and removed to an approved upland area for disposal. No debris is permitted in tidal wetlands and or protected buffer areas. 3. There shall be no disturbance to vegetated tidal wetlands or protected buffer areas as a result of the permitted 'activity. 4. Disturbance to the natural vegetation or topography greater than 25 feet seaward of the approved structure-is prohibited. 5. Necessary erosion control measures i.e.,haybales,silt fencing,etc.are to be placed on the downslope edge of any disturbed area. This sediment barrier is to be put in place before-any disturbance of the ground occurs and is to be maintained in good condition until thick vegetative cover is established. DEC PERMIT NUMBER PAGE 2 of 4 1-4738-03544/00001 ADDITIONAL GENERAL CONDITIONS FOR ARTICLES 15(TITLE 5),24,25,34 AND 6NYCRR PART 608 (TIDAL WETLANDS) 1. If future operations by the State of New York require an alteration in the position of the structure or work herein authorized, or if, in the opinion of the Department of Environmental Conservation it shall cause unreasonable. obstruction to the free navigation of said waters or flood flows or endanger the health,safety or welfare of the people of the State,or cause loss or destruction of the natural resources of the State,the owner may be ordered by the Department to remove or alter the structural work,obstructions,or hazards caused thereby without expense to the State,and if,upon the expiration or revocation of this permit,the structure,fill,excavation,or other modification of the watercourse hereby authorized shall not be completed,the owners,shall,without expense to the State,and to such extent and in such time and manner as the Department of Environmental Conservation may require,remove all or any portion of the uncompleted structure or fill and restore to its former condition the navigable and flood capacity of the watercourse. No claim shall be made against the State of New York on account of any such removal or alteration. 2. The State of New York shall in no case be liable for any damage or injury to the structure or work herein authorized which may be caused by or result from future operations undertaken by the State for the conservation or improvement of navigation,or for other purposes,and no claim or right to compensation shall accrue from any such damage. 3. All necessary precautions shall be taken to preclude contamination of any wetland or waterway by suspended solids, sediments, fuels, solvents, lubricants, epoxy coatings, paints, concrete, leachate or any other environmentally deleterious materials associated with the project. 4. Any material dredged in the conduct of the work herein permitted shall be removed evenly,without leaving large refuse piles,ridges across the bed of a waterway or floodplain or deep holes that may have a tendency to cause damage to navigable channels or to the banks of a waterway. 5. There shall be no unreasonable interference with navigation by the work herein authorized. 6. If upon the expiration or revocation of this permit, the project hereby authorized has not been completed, the applicant shall,without expense to the State,and to such extent and in such time and manner as the Department of Environmental Conservation may require,remove all or any portion of the uncompleted structure or fill and restore the site to its former condition. No claim shall be made against the State of New York on account of any such removal or alteration. 7. If granted under 6NYCRR Part 608,the NYS Department of Environmental Conservation hereby certifies that the subject project will not contravene effluent limitations or other limitations or standards under Sections 301,302,303, 306 and 307 of the Clean Water Act of 1977(PL 95-217)provided that all of the conditions listed herein are met. 8. At least 48 hours prior to commencement of the project,the permittee and contractor shall sign and return the top portion of the enclosed notification form certifying that they are fully aware of and understand all terms and conditions of this permit. Within 30 days of completion of project,the bottom portion of the form must also be signed and returned, along with photographs of the completed work and, if required,a survey. . 9. All activities authorized by this permit must be in strict conformance with the approved plans submitted by the applicant or his agent as part of the permit application. Such approved survey was prepared by John Metzger last revised on 11/28/05. DEC PERMIT NUMBER PAGE 3 of 4 1-4738-03544/00001 NOTIFICATION OF OTHER PERMITTEE OBLIGATIONS Item A: Permittee Accepts Legal Responsibility and Agrees to Indemnification The permittee,excepting state or federal agencies, expressly agrees to indemnify and hold harmless the Department of Environmental Conservation of the State of New York,.its representatives,employees,and agents("DEC")for all claims, suits,actions,and damages,to the extent attributable to the permittee's acts or omissions in connection w!-th the permittee's undertaking of activities in connection with,or operation and maintenance of,the facility or facilities authorized by the permit whether in compliance or not in compliance with the terms and conditions of.the permit. This indemnification does not extend to any claims, suits, actions, or damages to the extent attributable to DEC's own negligent or intentional acts or omissions,or to any claims,suits,or actions naming the DEC and arising under article 78 of the New York Civil Practice Laws and Rules or any citizen suitor civil rights provision under federal or state laws. Item B: Permittee's Contractors to Comply with Permit The permittee is responsible for informing its independent contractors, employees,.,agents and assigns of their responsibility to comply with this permit, including all special conditions while acting as the permittee's agent with respect to the permitted activities, and such persons shall be subject to the same sanctions for violations of the Environmental Conservation Law as those prescribed for the permittee. Item C: Permittee Responsible for Obtaining Other Required Permits The permittee is responsible for obtaining any other permits,approvals, lands, easements and rights-of-way that may be required to carry out the activities that are authorized by this permit. Item D: No Right to Trespass or Interfere with Riparian Rights This permit does not convey to the permittee any right to trespass upon the lands or interfere with the riparian rights of others in order to perform the permitted work nor does it authorizethe impairment of any rights,title,or interest in real or personal property held or vested in a person not a party to the permit. GENERAL CONDITIONS General Condition 1: Facility Inspection by the Department The permitted site or facility,including relevant records,is subject to inspection at reasonable hours and intervals by an authorized representative of the Department of Environmental Conservation (the Department)to determine whether the permittee is complying with this permit and the ECL.Such representative may order the.work suspended pursuant to ECL 71-0301 and SAPA 401(3). The permittee shall provide a person to accompany the Department's representative during an inspection to the permit area when requested by the Department. A copy of this permit, including all referenced maps, drawings and special conditions,must be available for inspection by the Department at all times at the project site or facility. Failure to produce a copy of the permit upon request by a Department representative is a violation of this permit. General Condition 2: Relationship of this Permit to Other Department Orders and Determinations Unless expressly provided for by the Department, issuance of this permit does not modify, supersede or rescind any order or determination previously issued by the Department or any of the terms,conditions or requirements contained in such order or determination. General Condition 3: Applications for Permit Renewals or Modifications The permittee must submit a separate written application to the Department for renewal,modification or transfer of this permit. Such application must include any forms or supplemental information the Department requires. Any renewal, modification or transfer granted by the Department must be in writing. The permittee must submit a renewal application at least: a) 180 days before expiration of permits for State Pollutant Discharge Elimination System (SPDES), Hazardous Waste Management:.Facilities (HWMF), major Air Pollution Control (APC) and Solid Waste Management Facilities (SWMF); and b) 30 days before expiration of all other permit types. Submission of applications for permit renewal or modification are to be submitted to: NYSDEC Regional Permit Administrator, Region 1,SUNY Bldg#40, Stony Brook NY 11790-2356 General Condition 4: Permit Modifications,Suspensions and Revocations by the Department The Department reserves the right to modify,suspend or revoke this permit in accordance with 6 NYCRR Part 621. The grounds for modification,suspension or revocation include: a) materially false or inaccurate statements in the permit application or supporting papers; b) failure by the permittee to comply with any terms or conditions of the permit; c) exceeding the scope of the project as described in the permit application; d) newly discovered material information or a material change in environmental conditions,relevant technology or applicable law or regulations since the issuance of the existing permit; e) noncompliance with previously issued permit conditions,orders of the commissioner,any provisions of the Environmental Conservation Law or regulations of the Department related to the permitted activity. DEC PERMIT NUMBER PAGE 4 OF 4 1-4738-03544/00001 1 ' New York State Department of Environmental Conservation Division of Environmental Permits Building 40 - SUNY, Stony Brook, NY 11790-2356 Telephone (631) 444-0404 'tame Facsimile (631) 444-0360 Denise M.Sheehan Commissioner January 5, 2006 Ms. Linda Bertani 1380 Oakwood Drive Southold,NY 11971 RE: 1-473 8-03 544/00001 Dear Permittee: In conformance with the requirements of the State Uniform Procedures Act(Article 70, ECL) and its implementing regulations (6NYCM Part 621) we are enclosing your permit. Please read all conditions carefully. If you are unable to comply with any conditions, please contact us at the above address. Also enclosed is a permit sign which is to be conspicuously posted at the project site and protected.from the weather. Sincerely, Darleen M. Gerbino Environmental Analyst DMG/ls Enclosure 95-20-1(11/03)-9d New York State Department of Environmental Conservation The.. Department of Environmental. Conservation (DEC) has issued permits) pursuant to the Environmental Conservation Law. for --work being conducted at this, site. For further information regarding the nature and extent of the approved work and any Department conditions applied to .the approval, contact'the Regional Permit Administrator listed below. Please refer to'the permit number shown when contacting the DEC. Regional Permit Administrator Permit Number S+d 0 W. PA A t Expiration Date NOTE: This notice is NOT a permit OAKWOOD DRIVE N 83°05'30" F LA&SCAPE TIE f BB 110.00' mnd APRON _ i 4 pits �O cr ONE A�p� O O . 4 N I WELL M I I N N SToq,F BB OR�VE7Yq y BB APRON - o ??8 N WAVDOW M � 2/,4' 2.STY. FR. HSE. E GARAGE , 4 BAY SAY IA. SB.O• WNDOW 36.0, 0 = DECK Pro p SGrccn a U i7' porch W - - -- W -j 3 Quo cp. 0 _ o o 3 0 Q LL to a o (D _ � z � z • a►' _ �nd LV ct )non. 1 -M z p man, Co O.PN, SURVEY FOR o . °s '� `� �F °'50�� JOHN BERTANI cl AT SOUTHOLD TOWN OF SOUTHOLD F.�. SUFFOLK COUNTY , N .Y. 1000 - 70 - 12 - 32 SCALE 1 " = 40 � JUNE 9 , 198 6 OCT. 16, 2003 (DECK LOC OCT. 4, 2005 (additional) OF tk"YObk OETZ NX. SDL' �. 41e APPRCQVED AS PLIL 7'L'l;Aiai AND CONDIT10-s S OEM 0 3 SU� 0 000/ W.Y. S. LIC. NO. 49618 PEF.MIr o. -`1?3� I DATE PE ORS, P. C. ( 631 - 5 0 2 0 FAX (631) 765 - 1797 P. 0. BOX 909 1230 TRAVELER STREET SOUTHOLD, N. Y. 11 971 86 - 163 A FORM NO. 3 NOTICE OF DISAPPROVAL DATE: January 22, 2007 TO: Linda Bertani 1380 Oakwood Dr. Southold,NY 11971 Please take notice that your application dated January 22, 2007 For a porch addition to an existing single family dwelling at Location of property 1380 Oakwood Dr., Southold, NY County Tax Map No. 1000 - Section 70 Block 12 Lot 32 Is returned herewith and disapproved on the following grounds: The proposed construction on this non-conforming 30,492 square foot parcel in the R-40 District is not permitted pursuant to Article XXIII Section 280-122A which states; "Nothing in this article shall be deemed to prevent the remodeling, reconstruction or enlargement of a non-conforming building containing a conforming use, provided that such action does not create any new non-conformance or increase the degree of non-conformance with regard to the regulations pertaining to such buildings." The existing single-family dwelling on this corner lot,notes front yard setback of 36' feet. The proposed screened porch addition is indicated at 36'. Pursuant to the interpretation in Walz (#5039) such additions and alterations will thus constitute an increase in the degree of nonconformance. Therefore the proposed addition is not permitted pursuant to Article XX III, Section 280- 124 which states that non-conforming lots,measuring between 20,000 square feet and 39,999 square feet in size, require a minimum front yard setback of 40' feet. Authorized Signature FORM NO. 3 NOTICE OF DISAPPROVAL DATE: April 19, 2006 TO: Linda Bertani 1380 Oakwood Dr. Southold,NY 11971 Please take notice that your application dated April 18, 2006 For a porch addition to an existing single family dwelling at Location of property 1380 Oakwood Drive, Southold County Tax Map No. 1000— Section 70 Block 12 Lot 32 Is returned herewith and disapproved on the following grounds: The proposed construction, on this non-conforming 30,492 square foot parcel in the R-40 District, is not permitted pursuant to Article XXIV Section 100-242A which states; Nothing in this article shall be deemed to prevent the remodeling, reconstruction or enlargement of a non-conforming building containing a conforming_use,provided that such action does not create any new non-conformance or increase the degree of non-conformance with regard to the regulations pertaining to such buildings. The existing single-family dwelling, on this corner lot,notes a front yard setback of 36' feet. The proposed screened porch addition is indicated at 36'. Pursuant to the interpretation in Walz (#5309), such additions and alterations will thus constitute an increase in the degree of nonconformance. Therefore, the proposed addition is not permitted pursuant to Article XXVI, Section 100-244, which states that non-conforming lots, measuring between 20,000 &39,999 square feet in total size,require a minimum front yard setback of 40' feet. Authorized Signature CC: file,Z.B.A. Note to Applicant: Any change or deviation to the above referenced application may require additional review from the Southold Town Building Department. U F- 0 D B[ tu - ER J pi _ t= z m z_ 3 w w a a i-- U Qh A 0Ail EXISTING ADDITION Z p Z U p Of 0 QO cl Z W Q O 2 w O :) O oo co O M Pq Lf) H ~ 2 O o a. I` Z EXISTIN& W m co HOUSE z0 - Q Z CD_ Q C) Q � o - -- - < Z Q � V � z r -i GRADE v W Q C--OCCUPANCY (aB -�L,* � USE IS UNLAWFUL CERTIFICAT,C ;,� OF � WITHOUT CERTIFICATE NAILINREQUIIREDCONNETIONS ` co '�OF OCCUPANCY � ,r � �.� ,, Z ALL CONSTRUu jotP SHALL ! s w r^-^ „ 1' . � "� MEET THE REQUIRES , THt , ,, z i,571Z CODES OF NE " W YORK STATE. -. ,©322 O LL ` yty FOR AIT H ` '�%"' " ,r;c►E SOUTHOLD BUILDING DEPARTMENT CRITERIA 0 O Z ! LUItiIZ>G 1 OCCUPANCY CLASSIFICATION R-3 RESIDENTIAL-SECTION 310 BUILDING CODE N.Y.S. _ if "U�,r�,`f IO 1 USE DWELLING UNIT-SECTION 310-310.2 P_� !w, . �;C;t,ISTRUWTION MUST 2 HEIGHT TOTAL V-9 1/2" , : .L tr'" .T ?s_I.y FIRE AREA(sf ;.;EY"� 3 TYPE OF CONSTRUCTION WOOD FRAME CONSTRUCTION FOR 4 DESIGN CRITERIA PRESCRIPTIVE DESIGN- 1995 HIGH WIND EDITION WFCM ULSIuN C�j (;01vS-fRUCTION ERRORS. 5 FRAMING ELEMENTS SEE FLOOR PLANS AND SECTIONS 6 DESIGN LOAD CALCULATIONS SEE SHEET 4 UNDERWRITERS CERTIFICATE 7 WINDOW AND DOOR SCHEDULE N/A Lo REQUIRED 8 LOAD PATH SEE SHEET 4 LL 9 NAILING SCHEDULE SEE SHEET 4 O 10 EGRESS WA <<`„ 11 PLUMBING RISER DIAGRAM N/A o 12 FIRE PROTECTION N/A z 13 TRUSS DESIGN DRAWINGS N/A w z 14 ENERGY CALCULATIONS N/A w J V) [-I I-oil I-oil I -oil \j �I I� EXI5TING ADDITION o 12 PIER 5 -O 5 -O 5 -O o = EXISTING "X10��3� HDR ° o �= o cv 4 - v 7 o ---- w3: d SCREEN PORCH Q '� Q ON EXISTING DECK A o - z w EXISTING = A A DECK O GPI 40 qY2" ® 16" OG RR cry EX I ST I NG co ry N HOUSE p Z = o IT CL allP I ER Isis _ cv m W Y O EXI5TING (TYP) O = W a0 � EXI5TIN6 2"XIO" ACQ GI R5 z O 00 CD o EX I ST I NG GRADE A Nco -� /A HOUSE I =I I*,,' EXIST. 2"XS" I =I i =I i : I w 8 �S PIERA00 FJ L. . 12" ,e PIER co 8'-O" 6'-6" 2'-2" i O a PROPOSED FLOOR/FRAMING PLAN W � M 1�I SCALE: y4" = I'—o" PROPOSED SOUTH ELEVATION W , SCALE: y4" I'_O" Q z o O o z ti co Fs\ co ADDITION EXI5TIN6 EXI5TING ADDITION w w z w DECORATIVE v r RAFTER TAILS z #sue d•'Y F EX I ST I NG o HOUSE z z - = O O � EX I ST I NCB t— a�F� 0322sa t A HOUSE A 9°FESSI NP w z z �— GRADE I GRADE x i • i '� '� r" a r" a r''a w tu 12" PIER L C_ �, —�� 8�� PIER (TYP) 51_411 6'-o„ a O N N PROPOSED NEST ELEVATIONEj PROP05F.D F.A5T ELEVATION z SCALE: y4" = 1'-O" ~ w a 50ALE: y4" = 1'-0" v Q_ ASPHALT NAILABLE DECK 12"'O.C. Z O O _ N • '12"'O.C. '• .• . N m m p • 9" Oc •. ' Z 3 � w a a F- 2 U Q �. A vi A IM 11 1/3- U 0 Z °• 0 O0 0 ASPHALT— W COATED m Z Y O BASE SHEET Z W Q EDGE OF ROOF I W O D ASPHALT AGGREGATE FIBER FELTASPHALTS O m 00 M m 5/5" SHEATHING W/A5PHLT THREE—PLY OVER NAILABLE DECK _ NOTES P4 ROOFING 5EE DETAIL A 1. If applied over sheathingpanels, add rosin—sized sheathing paper between the deck and p 2111XIO" DF base sheet. P 9 P Pe —� BLOCKING (TYP) 2. In lieu of asphalt. coal tar is an acceptable product. GPI 40 qY2" WOOD I �16" OG EXISTING SOFFIT DECORATIVE � T o RAFTER TA i L5 O , (2)2"x I O" DF HDR (TYP (2)2"x I O" D F Z ~ v HDR (TYP) CUSTOM' MAHOGANY FRAME5 WITH p Z o SGREEN.S Z WALL- GON5T T. .01 10 VINYL 5 f D I N6 (MATCH HOUSE) OVER TYYEK Z `O EXISTING ON 5/e "' CDX PLY. ON #2 D.F. 2"X4" 2 16" OG HOUSE - ON ACQ 2"X6" PLATE W/ APPROVED (� HURRICANE STRAPS TO HDR (SEE SPECS. 5HEET) Q FIN15H IINTERIOR W/y2"X6" AZEK BEADBOARD EX 15T1 NG 2"x5" ACQ FJ 2 16" OG t; l� � EXISTING 2"X6" Z co EX 15TI NG 2 lixio AGG►2 PLATE {— W AGQ GIRDER GRADE Z X UJI elf 0 0 5" OFESS{O?1�`. ✓ SECTION A-A_ ` 50ALE: 5/e" = 1'-0" u7 LL O M N Ej Z I— W Q 2 _I W Q_ GENERAL CONSTRUCTION NOTES GENERAL FRAMING NOTES NAILING SCHEDULE I 1.The information on this set of construction documents is to relate basic design 1.All walls,2x4 and 2x6,to be stud grade or better 16"o/c. All other framing material TABLE 3.1, INCLUDING 3.3 AND 3.9 j intent and framing details. They are intended as a construction aid,not a substitute to be#2 douglas fir or better. 1995 SBC HIGH WIND EDITION WOOD F R A ME CONSTRUCTION M A N U A L for generally accepted good building practice and compliance with current New York JOINT DESCRIPTION NAIL QUALITY NAIL SPACING state building codes. The general contractor is responsible for providing standard 2.All wood framing in contact with concrete or masonry to be pressure treated. construction details and procedures to ensure a professionally finished,structurally ROOF FRAMING = RAFTER TO TOP PLATE TOE NAILED 8'-0" WALL: 3-8d PER RAFTER � V sound,and weatherproof completed product. 3. Provide double floor joists under all walls parallel to floor joist span direction unless ; 10'-0• WALL: 4-8 d PER RAFTER otherwise specified. CEILING JOIST TO TOP PLATE TOE NAILED 8'-0" WALL: 3-8d PER JOIST 2.General Contractor to coordinate all sub contractors,scheduling of work,and 1 W-0" W A L L: 4-8 d PER JOIST O interaction between trades. 4. Provide x-bracing or solid blocking at a maximum of 8'-0"o/c for all dimensional CEILING JOIST TO PARALLEL RAFTER FACE NAILED S E E TABLE 3.7 EACH LAP V 9 9 CEILING JOIST LAPS OVER PARTITIONS 'FACE NAILED SEE TABLE 3.7 EACH LAP lumber floor joists. COLLAR TIE TO RAFTER FACE NAILED SEE TABLE 3.4 PER TIE tL tj 3.The general contractor is responsible for ensuring that all work and construction BLOCKING TO RAFTER 'TOE NAILED 2-8 d EACH END V Z Q Z meets or exceeds current federal,state,and local codes,ordinances and regulations, 5. Floor construction:%"tongue and groove plywood subfloor. Finished material to be RIM BOARD To RAFTER END NAILED 2-1 6 d EACH END Z to etc. These codes are to be considered as part of the specifications for this building applied over subfloor. Glue and screw plywood decking to floor joists. WALL FRAMING to and should be adhered to even if they are in variance with the plan. T o P PLATE TO TOP PLATE �F A C E NAILED 2-1 6 d PER FOOT 6.All window and door headers to be minimum(2)2x10 unless otherwise specified. TOP PLATES AT INTERSECTIONS FACE NAILED 4-1 6 d JOINTS - EACH SIDE STUD TO STUD ;FACE NAILED 2-16d 24" O/C 4. Dimensions shall take precedent over scale drawings(do not scale drawings). All interior headers to be(2)2x10 unless otherwise specified. HEADER TO HEADER FACE NAILED 1 6d 16' O/C ALONG EDGES 'Z-' W TOP OR BOTTOM PLATE TO STUD END NAILED 2-16d PER 2X4 STUD 3 J W 5.The designer has not been engaged for construction supervision and assumes no 7. Provide full solid blocking under all bearing walls. 3-1 6 d PER 2 xs STUD W ¢ < 4-16d PER 2X8 STUD U >_ responsibility for construction coordinating With these plans, nor responsibility for BOTTOM PLATE TO FLOOR JOIST, construction means, methods,techniques, sequences,or procedures,or for safety 8.All beams to have adequate bearing at each end or as specified. B A N D J o IS T, END JOIST, OR BLOCKING 'FACE NAILED 2-1 6 d - PER FOOT precautions and programs in connection with the worts. There are no warranties for a FLOOR FRAMING ' specific use expressed or implied in the use of these plans. 9.All flush beam and joist intersections to have galvanized hangers. JOIST TO SILL, TOP PLATE, OR GIRDER !TOE NAILED 4-8 d PER JOIST BRIDGING TO JOIST JOE NAILED 2-8d EACH END 6. Refer to floor plans,exterior elevations,and window schedule for types and sizes of 10.A typical structure that is designed as a"Partially Enclosed Building"shall have BLOCKING TO JOIST 'TOE NAILED 2-8 d EACH END Z U > BLOCKING TO SILL OR TOP PLATE TOE NAILED 3-16d EACH BLOCK Q 0 Z windows. All windows to be Andersen high performance quality or approved equal. exterior walls and roof to be sheathed With e'exterior grade plywood or LEDGER STRIP TO BEAM i F A C E NAILED 3-1 6 d EACH JOIST I- O O Q "OSB plywood,group 1,APA rated. Plywood to span over all plates and headers. JOIST ON LEDGER TO BEAM TOE NAILED 3-8 d PER JOIST a O J 7. Door and window headers to align unless otherwise noted. BAND JOIST TO JOIST END NAILED 3-1 s d PER JOIST W O BAND JOIST TO SILL OR TOP PLATE 'TOE NAILED 2-16d PER FOOT m Z 11. Provide insulation baffles at eave vents between rafters. W Y 2 8.General contractor is to ensure that masonry and prefabricated fireplace ROOF SHEATHING = W O 0 construction meets or exceeds all manufacturer's specifications and applicable codes. 12. Exterior flashing to be correctly installed at all connections between roofs,walls, STRUCTURAL PANELS 4' P E R IM E TE R EDGE ZONE - 16- O/C - 6- AT PANEL O W O O chimneys, projections,and penetrations as required by approved construction EDGES AND AT INTERMEDIATE SUPPORTS IN THE -3 V 00 m 9.General contractor to consult and coordinate with the owner and the plans for all practices. s d PANEL FIELD (� M P P I INTERIOR ZONE - 16" O/C - 6' AT PANEL EDGES AND 12" � built in items such as bookcases,shelving, pantry,closets,etc. 8d AT FOR ROOF SHEATHING WITHIN 4'-0" OF THE PERIMETER EDGE OF THE ROOF, INCLUDING 4-0" ON SUPPORTSIATE SIDE OF THEROOF PEAK, THE 4.-0. 13.General contractor t0 provide adequate attic ventilation and roof Vents. Q PERIMETER EDGE ZONE ATTACHMENT REQUIREMENTS SHALL BE USED. � 10. Provide hardwired smoke detectors,With battery backup,on all floors and in each bedroom,verify with local code requirements as per Section R317, New York State 14. Provide appropriate soffit ventilation at overhangs. CEILING SHEATHING Residential Construction Code. Install carbon monoxide detectors as per code. GENERAL PLUMBING NOTES GYPSUM WALLBOARD 5 d COOLERS 7" EDGE / 10" FIELD WALL SHEATHING GENERAL FOUNDATION NOTES 1. Plumbing subcontractor to be responsible for adhering to all applicable code and STRUCTURAL PANELS 8 d 4' E D G E ZONE - 16' O/C - 6" AT PANEL EDGES AND 12- f- AT INTERMEDIATE SUPPORTS IN THE PANEL FIELD I' LO safety requirements. 8d INTERIOR ZONE - 16" O/C - 6" AT PANEL EDGES AND 12" O 1.General contractor to review plans,elevations,and details to determine intended i AT INTERMEDIATE SUPPORTS IN THE PANEL FIELD O heights of finished floor(s)above typical grade. 2. If wall plates or joists are cut during the installation of plumbing fixtures or FIBERBOARD PANELS I7/1 6" 6 d 3" E D G E / 6" FIELD a ti 25132" 8d 3" EDGE / 6" FIELD Z equipment provide bracing to be framing back together. GYPSUM WALLBOARD 5 d COOLERS 7" EDGE / 10" FIELD W tj 2.All footings to rest on undisturbed soil. i 8 d 4' EDGE ZONE - 16" O/C - 6" AT PANEL EDGES AND 12- W M GENERAL HVAC SYSTEM NOTES HARDBOARD i AT INTERMEDIATE SUPPORTS IN THE PANEL FIELD I (o 3. Provide'/"expansion joint material between all concrete slabs and abutting concrete or masonry walls occurring in exterior or unheated interior areas. 1. Mechanical subcontractor is responsible for adhering to all applicable codes and safety requirements. TABLE 3.7 Q p Z C:) 4. Concrete on 4"sand or gravel fill minimum,with 6x6-10/10 wire mesh reinforcing. 1995 SBC HIGH WIND EDITION WOOD FRAME Ix 0 O Interior slabs to be placed on 6 mil.stabilized polyethylene vapor barrier. 2. HVAC subcontractor to fully coordinate all system data and requirements with the equipment supplier. CONSTRUCTION MANUAL Z ti 5. Provide crawl space ventilation per local code requirements. RAFTER SPACING 16' O/C CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA Q 3. HVAC subcontractor to provide final system layout drawing and submit it to general WEATHERING SEVERE 6. General contractor to install cop-r-tex(or copper)sheet metal termite shields contractor,owner,and equipment supplier for final review and approval. ROOF PITCH ROOF SPAN FROST LINE DEPTH 3'-0" between all wood surfaces that are exposed to concrete or masonry surfaces. 12 20 281 36 TERMITE MODERATE TO HEAVY 7. Dampproof exterior of foundation with a bituminous coating as per code and soil 3:12 5 8 11 14 DECAY SLIGHT TO MODERATE 4:12 4 6 8 11 WINTER DESIGN TEMP. 11 conditions. 5:12 3 5 7 9 ICE SHIELD UNDER- AS PER MANUFACTURER'S GENERAL WIND PROTECTION CONNECTION NOTES LAYM ENT REQUIRED SPECIFICATIONS STATE CODE GENERAL FLOOR PLAN NOTES 7:12 3 4 5 6 Adapted from Standard for Hurricane Resistant Residential Construction;SSTD 10-99 FLOOD HAZARDS -, and 1995 SBC High Wind Edition Wood Frame Construction 9:12 3 3 41 5 1. Dimensions shall take precedent over scale drawings(do not scale drawings). , Fasteners and Connectors for Wood Frame Construction T2.121 3 3 31 4 2.All interior walls to be covered with'/"gypsum board with metal comer reinforcing. 1.A continuous load path between footings,foundations walls,floors,studs and roof - \ Tape,float,and sand(3 coats). framing shall be provided. U) TABLE 3 .4 1'._:_ `f;) a 3.Walls common to garage and house to have a layer of 5/8",fire rated sum board 1 9 9 5 SBC HIGH WIND E D IT lO N WOOD �'° a : a' g g y gyp 2.Approved connectors,anchors and other fastening devices not included in the - W F- at garage side with 5'-0"return on adjacent walls and ceiling. Manufactured lumber Standard Building Code,Table 2306.1 shall be installed in accordance With FRAME CONSTRUCTION MANUAL 0322641 `�' / Z requires 2 layers of 5/8",fire rated gypsum board. manufacturer's recommendations. RAFTER SPACING 16" o/c ; DESIGN LOAD CALCULATIONS `` q �� . W 120 mph FASTEST W INDSPEED �r $S104 V 4.All bath and toilet area walls and ceilings adjacent to wet areas to have water 3. Metal plates,connectors,screws, bolts,and nails exposed directly to the weather or MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS Ibs ` O resistant gypsum board,or wall the set on wonderboard or equal. ROOF ROOF NUMBER ( fl l� 1 1/ � Z subject to salt corrosion in coastal areas, shall be stainless steel or hot dipped P IT C H SPAN (ft) O F NAILS EXTERIOR BALCONIES 60 / galvanized. Z4:12 12 3 DECKS 40 �4 O 4.Where Windows and doors interrupt wood structural panel sheathing and siding, 16 a ATTICS WITHOUT STORAGE 30 2 0 5 ATTICS WITH STORAGE 40 U_ framing anchors or connectors shall be provided at the top and bottom of cripple 24 s studs, header studs,and at least one stud at each side of opening. 28 7 ROOMS (OTHER THAN SLEEPING ROOMS) 40 32 8 SLEEPING ROOMS 30 Z 5. Ridge straps shall be attached to each pair of opposing rafters except where collar 36 - W ties of 1x6 or 2x4 lumber is located in upper third of attic space and attach to each pair 5:12 12 3 1 6 4 CRITERIA FOR CALCULATION OF DEAD LOAD ^ , 2 of rafters. �L/ O 20 a ACTUAL WEIGHTS OF MATERIALS REFERENCED TO A.I.A. _ 6.When a structure is designed as a"Partially Enclosed Building" uplift connectors 24 5 ARCHITECTURAL GRAPHIC STANDARDS 28 s P_� shall now require 20 gage strapping with six 8d nails provided at each rafter bearing. 32 7 36 7 SNOW 7. Floor to floor hold-downs to be provided every 48,and every 16"within 4'of exterior 6:12 12 3 IGROUND SNOW LOAD 45 lbs. comers. 16 3 20 4 SEISMIC 8. Sill Plate to Foundation Anchorage: Sill plate shall be anchored to the foundation 24 5 with anchor bolts having a min. bolt diameter of 5/8"and 3"x 3"x 1/8"washers. A 28 5 DESIGN CATEGORY B minimum of one anchor bolt shall be provided Within 6 to 12 inches of each end of 32 6 each late. Anchor bolts shall have a minimum embedment of 7 inches in concrete/ 36 7 WIND co P 7:1 2-1 2:1 2 12 2 LL masonry foundations. Anchor bolts shall be located Within 12 inches of comers and at 16 3 WIND SPEED 120 mph spacing not exceeding 4 feet on center. 20 4 EXPOSURE CATEGORY B O v THESE NOTES ARE GENERAL CONSTRUCTTON NOTES. THEY ARE NOT 2 s s N SPECIFICALLY WRITTEN FOR THIS PLAN. THEY ARE TO BE CONSIDERED AS C3 32 s GENERAL GUIDELINES ONLY AND SHOULD BE DISCUSSED WITH YOUR 1 1 361 61 w Z GENERAL CONTRACTOR BEFORE CONSTRUCTION BEGINS. W Q = J r� 0.. RIDGE i RAFTER 0 v i USP RS250 AT 21 Q � tL r, v z p m a z m -7 z rA RAFTER/RIDGE/RAFTER wITHcT Q Q RAFTER KING STUDS A N A ara RIDGE RAFTER STUD = 0 USP RT16 OR(2)R17 Q U p Z RAFTER HEADER • ; I— O TOP PLATE TOP PLATE .; W a O J • USP RT3 m Z Y O USP RS250 AT 21 USP RT20 USP RS250 AT 18" W USP LS OR TMU IES WALL STUD WALL STUD USP RS250 AT 12" CONNECTION USP PRODUCT NUMBER 0 00 0 JACK STUDS A RAFTER/RIDGE/RAFTER WITH CT' RS250 21" M � RAFTER/RIDGE/RAFTER WITHOUT CT RS250 21"+LSSH179 �— B RAFTER/PLATE/STUD RT20 RAFTER/PLATE RT16 or(2)RT7 PLATEISTUD RS250 18" Al RAFTER/RIDGE/RAFTER W/OCT B RAFTER/PLATE/STUD B RAFTER/PLATE PLATE/STUD C HEADER/STUD HEADER/JACK C HEADERISTUD HEADER/ACKSTUD R 250 12" D FLOOR TO FLOOR KLFTA or RS250 36" E STUD/PLATE/SILL RS250 36" re LO O STUD/PLATE RS250 16" O PLATE/SILL MP6F Z ti F ANCHOR BOLTS STB16 v- G POST ANCHOR FOR DECKS PAU SERIES 0.) eM POST ANCHOR FOR COVERED PORCHES CBE SERIES (' - - o '1X6 OR 2X4-16"O/C COLLAR TIES MIN. Q Z C) O o Z ti �-- M (!J POST USP CBE P.C.FOOTING •. 2ND.FLOOR WALL STUD 2ND.FLOOR WALL STUD 1ST.FLOOR WALL STUD 1ST.FLOOR WALL STUD (VJ1 , co w 2ND.FLOOR PLATE 2ND.FLOOR PLATE Lt1 G POST ANCHOR FOR COVERED PORCHES F- Z SUBFLOOR SUBFLOOR 1ST.FLOOR PLATE 1ST.FLOOR PLATE U RIM BOARD RIM BOARD SUBFLOOR SUBFLOOR USP KLFTA USP RS250 AT 36" _.. r O USP RS250 AT 36" USP RS250 AT 16" Z RIM BOARD RIM BOARD �,`f P, ; �••� O 1ST.FLOOR TOP PLATES 1ST.FLOOR TOP PLATES ( 9 ; DOUBLE SILL PLATE '. POST DOUBLE SILL PLATE USP MP6FLIL 1ST FLOOR WALL STUD 1ST FLOOR WALL STUD FOUNDATION WALL d FOUNDATION WALL �" �% `f Q • .r• .: ,, •' :.t• .: USP PAU ``O 0322�e-. WW U000, .. P.C.FOOTING 'a PLI� rD'* FLOOR TO FLOOR rQ"% FLOOR TO FLOOR �ESTQQ/PLATE/SILL E STUD/PLATE PLATE/SILL G POST ANCHORS FOR DECKS LL O r- LO N i z F- W Q r J N �