Loading...
HomeMy WebLinkAbout33026-Z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-33277 Date: 09/18/08 THIS CERTIFIES that the building SINGLE FAMILY DWELLING Location of Property: 470 LAUREL CT LAUREL (HOUSE NO. ) (STREET) (HAMLET) County Tax Map No. 473889 Section 125 Block 4 Lot 24.11 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated MAY 4, 2007 pursuant to which Building Permit No. 33026-Z dated MAY 11, 2007 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is NEW SINGLE FAMILY DWELLING WITH PERGOLA AS APPLIED FOR. The certificate is issued to WALTER & NANCY JACOB (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL R10-07-0043 09/12/08 ELECTRICAL CERTIFICATE NO. 4012300 09/15/08 PLUMBERS CERTIFICATION DATED 05/29/08 RIDOLFI PLUMBING HEATING ALIZhorized Signature Rev. 1/81 �- Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY \PJ This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: l. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a cerlifVicate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: ` 1. Accurate survey of property shoNving all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling$25.00, Alterations to dwelling $25.00, Swinuning pool $25.00, Accessory building $25.00, Additions to accessory building $25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Conunercial $15.00 Date. _9643 New Construction: Old or Pre-existing Building: (check one) Location of Property: q ZQ L.avr-el CourA- Laurel House No. Street Hamlet Owner or Owners of Property: Uja\k,°C P :5aC16b anA NQWC j /A UalGab Suffolk County Tax Map No 1000, Section 0 a5 Block 04 Lot aN J l Subdivision Filed Map. Lot: Permit No. 330@(¢ Date of Perinit. I4� 10007 Applicant: ljQi-\Pr 0&ob Health Dept. Approval: Underwriters Approval: 'VZ Planning Board Approval: / Request for: Temporary Certificate Final Certificate: V (check ne) Fee Submitted: $ V)�, "6, zyaz >,7 Ap Signature FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 33026 Z Date MAY 11, 2007 Permission is hereby granted to : JACOB 470 LAUREL COURT LAUREL,NY 11948 for CONSTRUCTION OF A NEW SINGLE FAMILY DWELLING AS APPLIED FOR at premises located at 470 LAUREL CT LAUREL County Tax Map No. 473889 Section 125 Block 0004 Lot No. 024 . 011 pursuant to application dated MAY 4, 2007 and approved by the Building Inspector to expire on NOVEMBER 11, 2008 . Fee $ 3 , 066 .40 j 1 Authori ed Cigna ure ORIGINAL Rev. 5/8/02 TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILIING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey www.northfork.net/Southold/ PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees Examined ,20 Contact: Approved ,20 Mail to-.4, a Disapproved a/c P6�abz .� rc�' 1V7 Phone:ryZ 2 57b/5 Expiration ,20 Building Inspector APPLICATION FOR BUILDING PERMIT Date '0 � , 200T INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale.Fee according to schedule. b. Plot plan showing location of lot and.of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months.Thereafter, a new permit shall be.required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described.The applicant agrees.to comply with all applicable laws, ordinances,building code,housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Sign e of applicant or name,if a corporation) Po box 759 ay )6(4 097 (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder -F,V\e- ao l car1,+- S ` k(l , 0 wf1 eT Name of owner of premises Ala 14er P. Jo,c h (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No'. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: W t-70 Laurel Ccu� CL4vrti LihK got ia� Laurel House Number Street I,a5 Hamlet County Tax Map No. 1000 Section TV Block &W H � Lot `44-;-1 9L1. Subdivision Laurel Filed Map No. 1 b7la' Lot IS (Name) PtbS },No. 144 44 . 2.- State existing use and occupancy of premises and intended use and occupancy of proposed construction:- a. Existing use and occupancy V0,,C-C%rN 4- Lo'r b. Intended use and occupancy r 3. Nature of work (check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work (Description) 4. Estimated Co , 0 , oTr6 Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 3 Car g! t, e& e_ 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. A l a 7. Dimensions of existing structures, if any: Front NIA Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front N JA Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front -7Rear Depth Height Number of Stories 9. Size of lot: Front '/,Q Rear Depth 6 1 10. Date of Purchase �'I q I a n o3 Name of Former Owner Ae%, rew Wes ter Qmn!! W'c 1s-, 5ket%..,e 11. Zone or use district in which premises are situated 12. Does proposed construction violate an7w'jl ng law, ordinance or regulation? YES NO ✓ 13. Will lot be re-graded? YES NOl excess fill be removed from premises? YES NO W(kA-ela,a 1JAAC,3 PO i3ox 758 14. Names of Owner of premises Jacob Address gore-Spot+ N e t1g47 Phone No. 631- VD-501 Name of Architect Dan Aft-eJ Address l b B b3%R&r6&bAqMPhone No 631- 553- 6 S a4 Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO ✓ * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17..If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTY OF ) L77T,- tz. � _being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)He is the D LJ t4�e-2 (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this n q� day of A lLlyd7 2004- f f tary Public /6ature of Applicant LINDA SIEDLECKI NOTARY PUBLIC-STATE OF NEW YORK No. OI S16110504 _ Qualified in Suffolk County Commission Expires June O1, 2008 OF SO(/r6olo o cou TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 ( � INSPECTION � [ ] FOUNDATION 1ST [ ] ROUGH PLBG. i4rt6lz ' [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING FINAL " [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECT N [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATIO REMARKS: 0 A off ,� � titrtrL D J DATE ��/ INSPECTOR OF SO(/jyolo 3o TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION I ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [FINAL 4 f [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ✓� REMARKS: c C �6 DATE INSPECTOR SOl/,yO�o %00UMY Nc� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING X FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: ATE 7,3 D - INSPECTOR- SOUTyo�o -3,3o �� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: /V bLt DATE j INSPECTOR �O�apF SOUjyolo u�r+,��' TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING FINAL [ _ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION 477) REIVIARK � - � �'�'�`� `-S DATE INSPECTOR OF SOUryo�o 3 3 Z TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [INSULATION kil [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE A.CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: ® . r DATE INSPECTOR pF SO�ryo�o o urm,��' TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND JO�NSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: rele-k 04 �- . Lo �— /\/Le k)q- -DAT E O a INSPECTOR oF souryo�o 3.� o �'a� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION ' 7FRAMI'NG) STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: 7 / 'y \ u Y DATE a INSPECTOR SOUryOlo TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST XROUGH PLBG. ; [ ] FOUNDATION 2ND [ ] INSULATION XFRAMING STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: d ctJ 1vo7 1)4AIE r- DATE r ��� INSPECTOR OF SOUlyo�o 330� Z- u TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: B � p ok DATE INSPECTOR 1 .lek - . r_ OF SOUjyo�o 3,3 coUNTY,� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] FOUNDATION 2ND [ ] INSULATION FRAMING STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTR CTION; -�] FIRE RESISTANT PENETRATION REMARKS:- - G DATE /�� ® � I� INSPECTOR d = SO�ryO�o �o TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION O FRAMIN STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REtAARKS: Pv Ll DATE /"� ® � INSPECTOR OF SOUT,yolo �30P-67 urm,��' TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: I i 1 j .�f CdL.�j� z L2A ✓ DATE INSPECTOR -ION REPORT DATE COMMENTS FOUNDATION(IST) --------------------------- Via! 0 Cori ROUGH FRAMING& PLUMBING mam Ro Effj MAE".-701 9/ M%QA lWalwaiS v try, 1113117111M .91m,IS. .... EMMA 5 W.Al rl-Rt'_Wil' MA WA' 10 Ae Ell 2 1 - I wo W.-nm 1mvirMno 0 r�LnC.�L�C�C�CJ7C.I�LI�Ll�Ll7[J?C I�CI�LILIGnLI�G�C.��LI�C.ILl7CPC�f:PC17C�L)I�CPC.nC.nCJ7�Ll�C�[3WE.nCof:.�r�C.I�C.I�C.ILrC.I�CnffLn!] PC.I fib'!��LI�C�CnLnnC.�[.�LnLI�f 5 ' BY THIS CERTIFICATE OF COMPLIANCE THE 5 5 NEW YORK BOARD OF FIRE UNDERWRITERS 5 5 S 5 BUREAU OF ELECTRICITY 5 5 40 FULTON STREET - NEW YORK, NY 10038 5 CERTIFIES THAT 5 5 5 Upon the application of upon premises owned by 5 5 5 5 WALTER JACOB. WALTER JACOB PO BOX 758 PO BOX 758 lL�� 5 JAMESPORT NY 11947 JAMESPORT, NY 11947 d Cj 5 Located at 5 470 LAUREL CT LAUREL, NY 11948 5 5 Application Number: 4012300 Certificate Number: 4012300 5 5 _ 5c 5 Section: Block: Lot: Building Permit: „ BDC: nsl1 5 Described as a Residential occupancy, wherein the premises electrical system consisting of Cj S electrical devices and wiring, described below, located in/on the premises at: S 5 Basement,First Floor,Attached Garage,Outside,Attic, 5 5 5 5 A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed 5 5 herein, was conducted in accordance with the requirements of the applicable code and/or standard 5 5 promulgated by the State of New York, Department of State Code Enforcement and Administration, or other 5 5 authority having jurisdiction, and found to be in compliance therewith on the isth Day of September, 2008. 5 Name QTY Rate Ratins Circuits Tvoe C5, 5 AdditionalCharges Lj 5 as built-2007 S 5 Alarm and emergency equipment 5 5 Sensor 1 0 0 Carbon Monoxide 5 Sensor 6 0 0 Smoke r+ 5 Appliances and Accessories 5 5 Air Conditioner 2 0 Above 1500 BTU 5 5 Cooking Deck 1 0 30 Amps 5 5 Dish Washer 1 0 1.2 KW 5 5 Exhaust Fan 3 0 F.H.P S SFurnace 1 0 Oil 5 5 Hydro Massage Tub(Therapeutic) 1 0 5 5 Oven 2 0 9.0 KW 5 5 Service 5 5 Service Disconnect: 0 150 cb 5 Service Phase3w Service 5 Rating300Amperes 5 Wiring And Devices 5 5 Dimmer 12 0 120 V seal 5 Continued on Next Page 1 of 2 5 5 S 5 5 5 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. 5 5 0 LPLI�LI�LnCnLI�LI�GPLT2C.TL(LI�C.I�LI�LI�C.I�CPGI'GfC.I�C.I�CPCJ�CPC.(C.IC.I�CPC.I�LTLnC.I��LI7Ll?C.I��GI�LT2LI�C.I�CPLT2[.(LPCPCPCJ�LTC.I�GPC.I�LI�CPC.I�LlL1�CPC.I�C.I�G1�LlGPLI�C.I� ❑� r.1�ePr�rJ'2�rJrJ�rJ�eP�Pr�rJcTrTRIEr�r1ef�.PLIEL J'2J�leJUr nr�rJ Im��PrJenrJ�rJ�rJ�r PLPL�r�JrJLPLPPLLPLPLLPLPLlLrJLrJ'rJ2li l�rJ�rJ�rJ�rJ�L3PL PLPLPLJC3 5 BY THIS CERTIFICATE OF COMPLIANCE THE 5 5 NEW YORK BOARD OF FIRE UNDERWRITERS 5 5 S 5 BUREAU OF ELECTRICITY 5 5 40 FULTON STREET — NEW YORK, NY 10038 S� 5 CERTIFIES THAT 5 5 5 5 Upon the application of upon premises owned by 5 S 5 S WALTER JACOB WALTER JACOB 5 5 PO BOX 758 PO BOX 758 5 SJAMESPORT NY 11947 JAMESPORT, NY 11947 5 Located at 470 LAUREL CT LAUREL, NY 11948 5 5 5 5 Application Number: 4012300 Certificate. Number: 4012300 5 5 S 5 Section: Block: Lot: Building Permit: * BDC: ns11 �5 5 5 Described as a Residential occupancy, wherein the premises electrical system consisting of 5 electrical devices and wiring, described below, located in/on the premises at: CS, 5 Basement,First Floor,Attached Garage,Outside,Attic, 5 5 5 A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed 5 herein, was conducted in accordance with the requirements of the applicable code and/or standard 5 promulgated by the State of New York, Department of State Code Enforcement and Administration, or other 5 5 authority having jurisdiction, and found to be in compliance therewith on the 15th Day of September, 2008. 5 5 Name OTY Rate Rating Circuits im C� 5 Fixture 9 0 Low Voltage 5 5 Fixture 102 0 Incandescent 5 5 GFCI Circuit Breaker 1 0 5 S Outlet 111 0 Fixture 5 5 Outlet 125 0 Gen,Purpose 5 5 Paddle Fan 4 0 5 5 Receptacle 1 0 20a-laundry Appliance 5 Receptacle 9 0 GFCI 5 5 Receptacle 87 0 Gen,Purpose 5 Switch 69 0 Gen;Purpose 5 5 S 5 5 5 5 5 5 5 5 5 seal 5 5 2 of 2 5 5 5 5 - 5 5 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. 5 5 5 1 �RIER M������������������������������������� o Mug([P[J�[J�[1[1[n[J�[J�[n[P[1�[1 �[1010n[.fL:(a @f[1'[.t[rL3rL3��[,'MJ Q1[J�[1�[J�[J�[.r7[1�[J'[J�[.n[1@1'[J�[1�[J�[J�[1'[J�[.[.�'R: JMJ0[ aJ�l M 7M3[U3PRPRRPRP22PRPC c� 5 BY THIS CERTIFICATE OF COMPLIANCE THE 5 5 5 NEW YORK BOARD OF FIRE UNDERWRITERS 5 A F ELECTRICITY S 5 BUREAU O 5 5 40 FULTON STREET - NEW YORK, NY 10038 C� 5 CERTIFIES THAT 5 5 5 5 Upon the application of upon premises owned by 55, 5 WALTER JACOB WALTER JACOB LJ 5 PO BOX 758 PO BOX 758 AM SPORT, NY 11947 5 5 JAMESPORT NY 11947 5 5 Located at 470 LAUREL CT LAUREL. NY 11948 SApplication Certificate Number: 5 PP Number: 4012300 4012300 5 5 Section: Block: Lot: Building Permit: . BDC: nsl1 5 5 5 Residential 5 Described as a occupancy, wherein the premises electrical system consisting of 5 electrical devices and wiring, described below, located in/on the premises at: S 5 Basement,First Floor,Attached Garage,Outside,Attic, 5 5 5 A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed 5 Sherein, was conducted in accordance with the requirements of the applicable code and/or standard 5 promulgated by the State of New York, Department of State Code Enforcement and Administration, or other 5 5 5 authority having jurisdiction, and found to be in compliance therewith on the 15th Day of September, Zoos. 5 Name OTY Rate Ratine Circuits Tyne Amount S AdditionalCharges 5 as built-2007 $0.00 5 5 FUEL SURCHARGE $5.00 5 OVERNIGHT FEE $25.00 5 5 Alarm and emergency equipment 5 Sensor 1 0 0 Carbon Monoxide $0.00 5 5 Sensor 6 0 0 Smoke $0.00 5 5 Appliances and Accessories 5 5 Air Conditioner 2 0 Above 1500 BTU $0.00 CCJ 5 Cooking Deck 1 0 30 Amps $0.00 5 Dish Washer 1 0 1.2 KW $0.00 5 Exhaust Fan 3 0 F.H.P $0.00 5 Furnace 1 0 Oil $0.00 5 [5, 5 Hydro Massage Tub(Therapeutic) 1 0 $0.00 5 5 Oven 2 0 5 9.0 KW $0.00 5 Service 5 5 Service Disconnect: 0 150 cb 5 Servicel Phase3w Service $0.00 5 Rating300Amperes Wiring And Devices 5 5 5 Dimmer 12 0 120 V seal $0.00 �] Fixture 9 0 Low Voltage $0.00 SContinued on Next Page 1 of 2 5 re 5 5 This certificate may not be altered in any way.and Is validated only by the p sen ca of a raised seal at the location indicated. 5 5 o L����—��������������������������������������������������������Q o a cPrJ�rJ�i:JrJ�rJ'3rJ�rJ�rJ�rJ"rJ'rPcPrJ�r�r�rJLPLrL3L3rL3fJL3fL3 n�r�rJ�"C3jL3 rJ�r�rJ�rJrJ�rJ�rJ�rJ�cJ�rJ�rJ�c.I�rJ�rlrJ�rJ�rJ��rJ�rJ�rJ�rJ�cPrJ�rJ�rJ�rJ�rJ�rJ�rJ�cPrJ� 5 BY THIS CERTIFICATE OF COMPLIANCE THE 5 5 NEW YORK BOARD OF FIRE UNDERWRITERS 5 5 5 5 BUREAU OF ELECTRICITY 5 5 40 FULTON STREET — NEW YORK, NY 10038 C� 5 CERTIFIES THAT 5 5 5 5 Upon the application of upon premises owned by 5 C5 5 WALTER JACOB WALTER JACOB 5 5 PO BOX 758 PO BOX 758 5 5 JAMESPORT NY 11947 JAMESPORT, NY 11947 5 SLocated at 470 LAUREL CT LAUREL. NY 11948 _ 5 C5 SApplication Number: 4012300 Certificate Number: 4012300 5 5 5 5 Section: Block: Lot: Building Permit: * BDC: ns11 5 5 5 Described as a Residential occupancy, wherein the premises electrical system consisting of 5 electrical devices and wiring, described below, located in/on the premises at: 5 5 Basement,First Floor,Attached Garage,Outside,Attic, 5 5 5 A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed 5 5 herein, was conducted in accordance with the requirements of the applicable code and/or standard 5 promulgated by the State of New York, Department of State Code Enforcement and Administration, or other 5 authority having jurisdiction, and found to be in compliance therewith on the 15th Day of September, Zoos. 5 Name OTY Rate Rating Circuits Type Amount Fixture 102 0 Incandescent $0.00 �i�JJJ GFCI Circuit Breaker 1 0 $0.00 5 Outlet 111 0 Fixture $0.00 5 5 Outlet 125 0 Gen,Purpose $0.00 5 Paddle Fan 4 0 $0.00 5 LJ Receptacle 1 0 20a-laundry Appliance $0.00 5 Receptacle 9 0 GFCI $0.00 5 5 Receptacle 87 0 Gen,Purpose $0.00 5 Switch 69 0 Gen,Purpose $0.00 '7 Invoice Total $270.00 5 5 5 5 5 5 5 S 5 5 5 S 5 sea/ 5 2 of 2 5 5 5 5 5 5 This certificate may not be altered in any way and is validated only by the presence of a raised seal.at the location indicated. 5 5 5 o ������������������l�l������������ ���������� o CERTIFICATION Date: 2.q lob Building Permit No. 3SO-2(p Owner: UV P(.T8z dma) (Please print) Plumber: hDOL-F-1 Pukrh6wG, 4 NC-A-Twfi (Please print) WWI�L DU , I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. lumbers Signature) worn to efore me this day of 2008 of ublic, Su olk 6eNti Noftry PMllft.owft of Now yo* NM MA1MSMI Ouall8asl In Suffolk County MY COM rlaslon Expires April 21,2012 JAMES J. DEERKOSKI, P.E. 260 Deer Drive Mattituck, N.Y. 11952 (631) 298-7116 Date: September 16, 2008 To: Town of Southold Building Dept. Re: Footing/Strapping/Framing/Venting/Plumbing/Insulation Inspections Walter Jacob 470 Laurel Ct. Laurel, NY Permit# 33026 To Whom It May Concern: This letter certifies that all wind strapping on the above mentioned project is in tact, and meets all state and local building codes. A Footing inspection was made on interior and exterior footings and these footings were installed correctly. A Framing/Plumbing/ Insulation Inspection was also Performed on this Structure, and all framing, Insulation, and Plumbing was done correctly and also meets all state and local building codes. A pressure test was also performed on the waste/water plumbing systems. Also the ventilation holes were checked in the cathedral area and around the skylights and these holes were drilled in the proper locations.Any questions please feel free to call. l Jed :�O�- NEW�O`F g-' \DEE ! CO Gj �� � Sincerely Jame§ .leerkoski P.E. �. 07� tyOFESSi'�� Erosion, Sedimentation and Storm-water Run-off Control Plan ASSESSMENT FORM Yes. No. EXEMPTIONS:. A. Does.this project meet the.minimum standards.for classification as.an Agricultural Project. _ ,Note: If you.answered.Yes.to any.of the.above,a Storm-water,Grading,.Drainage.&.Erosion.Control.Plan is.not required. ------------------------------------------------------------------- ACTIONS.REQUIRING THE.SUBMISSION OF A STORM-WATER, GRADING.,DRAINAGE &EROSION. CONTROL.PLAN.CERTIFIED.BY A DESIGN.PROFESSIONAL.IN.THE.STATE.OF NEW.YORK.. Item Number:. (A Check Mark (J).for each question is required for complete.application) Yes. No. 1. Will this.project retain all Storm-Water Run-off generated on Site? (This:will include.all run-off created by site.clearing and/or construction activities.as.well as.all Site.Improvements.and the permanent creation of impervious.surfaces.). 2.. Will this.project require any land filling, grading or excavation where,there.is.a change to the natural existing grade.involving more.than 200 cubic yards.of material within any.parcel? K Will this.application require.land disturbing activities.encompassing an area. of five.thousand(5,000).square feet of ground surface or more? ❑ 4. Is.there.a,Natural Water.course.running through the.site or is.this.project within One.hundred(100).feet of wetlands or a beach? 5. Will there be.site.preparation on slopes which exceed fifteen(15).feet of vertical rise.to. / One.hundred(100).feet of horizontal distance? 6.. Will driveways,.parking areas or other impervious.surfaces.direct Stone-Water.Run-off into.and/or in the direction of a Town Right-of-Way? 7. Will this application require the placement of material,removal of vegetation and/or the. construction of any item within the Town Right-of-Way.or road shoulder area? (This.item,does.not include the.installation,of driveway aprons.) / 8. Will there be site preparation within the one hundred(100)year floodplain of any.watercourse? Note:. If any.answer to.questions one.through.eight is answered.with,a check mark in the.Box,.a Storm-water,Grading, Drainage.&Erosion.Control Plan is.required and must be submitted for.review prior to.issuance.of any building.permit. ------------------------------------------------------------------- STATE OF NEW YORK,COUNTY OF.... ..... ...................... ss That I 1-1�<- .� �- VontTactor, ' g duly sworn, deposes and says that he/she is the applicant for Permit (Name of individual signing Document) And that He/She is the ............ . ? .. 1 �1... ......:............................................. (Ownergent,Corporate Officer,etc.) Owner and/or representative of the Owner or Owner's,and is duly authorized to perform or have performed,the said work and to make and file this application;that all statements contained in this application are true to the best of his knowledge and belier;and that the work sill be performed in the manner set forth in the application filed herewith. Sworn to b f me this; ........... ............ .........day of ........ .. .......... 20� NotaryPublic: ... . ...... .. .. .................. ......... ............ BARBARA ANN RUDDER Signature of q plicant) Notary Public,State of New York No.4855845 Qualified in Suffolk County Commission Expires April 14, 1 Town Of Southold P.O Box 1179 Southold, NY 11971 * * * RECEIPT * * * Date: 05/04/07 Transaction(s): Reference Subtotal 1 1 Septic Permit-Construct- Resid. 3706 $10.00 Check#: 2118 Total Paid: $10.00 Name: Jacob, Walter Po Box 758 Jamesport, NY 11947 Clerk ID: BONNIED Internal ID:3706 Montalvo Construction Group, Inc. PO BOX 283 ♦ Westhampton Beach, New York 11978 Office (631)288-8881 ♦ Facsimile (631)288-1459 ' E-mail ♦ montalvo2010@optonline.net August 29, 2007 Southold Building Department PO Box 1179 Southold,NY 11971 Re: Permit No. 33026 Lot#18, Laurel Court Laurel,NY 11948 Enclosed please find the foundation survey for the above referenced property. I will follow up with your office in a couple days to see if it is okay for us to proceed. If you have any questions, please feel free to contact me at 631-965-5425. Thank you. Ih �� Kerrilynn Villafane Montalvo Construction Group, Inc. enclosure BUILDING PERMIT EXAMINER CHECKLIST *Date Submitted,5� f /010*Date Reviewed rJj0406A�D Applicant: Owner: a gAD r RD _ Architect ngineer:Q-_- ►gyp Estimated Costa, SCTM# 1000- - Subdivisio Zone: Conforming? Property Address! - q I4 Cit Pre COs? Building Permits (Open/Expired): BP -Z/C/o Z- Info; .,�z -Z/C/o Z- ,Info: BP -Z/C/0 Z- Info: BP Z/ BI'— -Z/C/o Z- Info: Single & Separate Search Required? Y o N D termination: _C REQ. Lot Size: ACT. Lot Size: RE Cov. ACT. Lot Cov. REQ. Front ACT. Front�fREQ Si ACT. Side fe< REQ. Re PROP. Rear✓ REQ. Height ACT. Height Project Description:UM Waterfront? Y ? If yes,water body: - Panel# Flood Zone-Bulkhead/Bluff Distance: -� ADDITIONAL APPROVALS REQUIRED Suffolk County ealt N- If yes, *Bed#: *Date: _/ *Permit#.--PP`0 Tow Sep ' _ I - If no equired: Y or N Received: Y or N By: - NYS DEC: PRE-DEC 9/1/75 Y Oro>te: / /_ Permit#: or NJ Letter-Notes: Southold Trustees: Y o NzTate: _/ / Permit#: or NJ Letter-Notes: Southold ZBA: Y o(Date: _/ / Permit#: -Notes: { Southold Planning: Y oN-ate: / / Permit#: -Notes: Town Landmark C of A: Y DT : / / *NYS CODE Compliance (page 2): Y or N Notes Fee Structure: Calculation: Foundation: 3W'y , SF 1. ( W4/,� SF)- (_�SF)=V&4 _SF X $ . 6/b =$311f 40 First Floor: SF + Initial Fee: $2p0 Second Floor: SF +Additional Fee ( ): $ Other: SF 2. ( SF)- _SF)= SF X $ =$ Total: a / SF +Initial Fee: $ + Additional Fee $ ZA TOTAL: $ 6 NEW YORK STATE CODE COMPLIANCE CHECKLIST CLIMATIC/GEOGRAPHIC DESIGN CRITERIA: Ground Snow Load: 45 Wind Speed: 120MPH Selsmic Design Category:B Weathering: Severe Frost Depth: 36" Termite: M-H' Decay: S-M Design Temp: 11 -Iee Shield Underlay: YES Flood Hazards: USE/OCCUPANCY CLASSIFICATION: HEIGHT/FIRE AREA: TYPE OF CONSTRUCTION: DESIGN CRITERIA: ENGINEERED/PRESCRIPTIVE FULL FRAMING DESIGN ELEMENTS: Y/N HEADERS: YIN WALL STUDS: YIN GIRDERS: YIN CEILING JOISTS: YIN FLOOR JOISTS:YIN ROOF RAFTERS: YIN LUMBER SPECIES AND GRADE: YIN DESIGN LOAD CALCULATIONS: Y/N LIVE: YIN DEAD: YIN SNOW: YIN SEISMIC: YIN WIND: YIN WINDOW AND DOOR SCHEDULE: MISSLE TEST REQUIREMENTS: Y/N EGRESS 5.7 S.F.: Y/N LIGHT 8%: Y/N VENT 4%: Y/N NAILING/CONSTRUCTION SCHEDULE: Y/N MEANS OF EGRESS: Y/N PLUMBING RISER DIAGRAM: Y/N LOCATION OF FIRE PROTECTION EQUIPMENT: YIN TRUSS DESIGN: Y/N CERTIFICATION: Y/N ENERGY CALCS: Y/N TOTAL COMPLIENCE? Y/N (RETURN TO PAGE ONE) LOT. f7 VACANT pEE: a .''U=- C "`v�```?ivs` ". 6 y o33ING i d"f;is'sl�,y "dr[ A e/3131 S �A�'E e/32 a 20'20�$Q.y �/ '6 APb 4 FOR iwuc /80.00, Imum op 191 O .9" E'OVe/oboe 0 I am familiar with the STANDARDS FOR APPROVAL �P ,� w so, AND CONSTRUCTION OF SUBSURFACE SEWAGE DISPOSAL SYSTEMS FOR SINGLE FAMILY RESIDENCES and will abide by the conditions set forth Ihereln and on Jhe permit to construct. �) h \ P —q 1b �N . f `Q�k� Q o �� ��� Q SURVEY OF PROPER T Y AT MA T TI TUCK Px o� TOWN OF SOUTHOLD, NY °° SUFFOLK COUNTY, MY e. 1000 - 125 - 04 - 24. 11 4" SCALE 1" = 30' �':•?, �1"� 0 4� SEPT. 25, 2002 ss Ile, 0 JQ Oct. 1, 2002 (CERTIFICA TIONS) OCT. 25, 2002 ( revision 1 OCT. 28, 2002 ( revision 1 Dew. 2/ Isjake O CERTIFIED TO: Nov /7, 2ooG (prap. hSe. PECONIC ABSTRACT, INC. J�q FIRST AMERICAN TITLE INSURANCE COMPANY -k o OF NEW YORK ANDREW WEXLER DANIEL J. WEXLER 'r SHELLEY WEXLER RODMAN ,1 Me10 6 h The locations of wells and cesspools a h� shown hereon are from field observations��ANY ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION ., ,, OF SECTION 7209 of THE NEW YORK STATE EDUCATION LAW. . and or from data obtained from others. :• ':� EXCEPT AS PER SECTION 7209 - SUBDIVISION 2. ALL CERT7FICATIONS HEREON ARE VALID FOR THIS MAP AND COPIES THEREOF ONLY IFSAID �� S. WHOSE SIGNAT OR U E/ APPEARS NEREONESSED SEAL OF THE SURVEYOR NOTE, L 0 T NUMBERS REFER TO 'MAP OF LAUREL LINKS' :ffAi— FILED IN THE SUFFOLK COUNTY CLERKS OFFICE ECONIC YORS, ADDITIONALLY TO COMPLY WITH SAID LAW TERM 'ALTERED BY • ON NOV. 23, 2001 AS FILE NO. 10712 (631) 765 - 5020 FAX MUST BE USED BY ANY AND ALL SURVEYORS UTILIZING A COPY P. 0. BOX 909 OF ANOTHER SURVEYORS MAP. TERMS SUCH 'NVSPECTED 'AND A .Fluke 1230 TRAVELER STREET ' 'BROUGHT - TO - DATE ' ARE NOT IN COMPLIANCE WITH THE LAW. AREA 30,885 sq. ft. SOUTHOLD, N.Y. 11971 02 - 298 or 17 VACANT Bair C/3/y 11- e/32.6S 20'20'5p, .� L o /80,00' 5� \ s® b1a9 Eve/owe o moo• - - -- 4 1 am fam/liar with the STANDARDS FOR APPROVAL so, %ND CONSTRUCTION OF SUBSURFACE SEWAGE o Nry�� ai DISPOSAL SYSTEMS FOR SINGLE FA MIL Y RESIDENCES JQ QJ0 �, u and w111 abide by the conditions set forth thereln and on the permit to construct. CK IV oM ryn' `� QP SURVEY OF PROPERTY T �.I\b COA T MA T TI,TUC Px tis / 2s° h 20 Sys. ®A� TOWN OF SOUT 'OLD )' SUFFOLK COUNTY' N Y F 1000 - 125 - 04 - 24, 11 .o. a SCALE.- 1" - 30" < zs r - o �Q SEPT: 25, 2002 3s3p O Q APRIL 16, 2007 -- AUG. 20, 2007 ( FNOTN LOC l' 14 `'' 17 AUG. 23, 2007 (CERTIFIC ;TIONJ`-- o� - 4 K07 0%, Q� CERTIFIED TO 1 t ;, SEP —{ ROOF AREA = 4500 SOFT WAL TER P. JACOB, 4500 x 0.17 l = 765 C UL S TER SAVING BANK,� x U.FT ti - ' 7651223 - 34VF FIDELITY NATIONAL TITLLE INS_ URAN_CEw- --'=— - PROVIDE 4 DRY WELLS 6'0 x 9 DEEP COMPANY OR EQUAL OF NEW � 6�0 h The locations o/ wells and cesspools y�P N.iAET ANY ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION ¢ y ,�h\ shown hereon are from field observations � OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW. and or from data obtained from olhers. EXCEPT AS PER SECTION 7209 - SUBDIVISION 2. ALL CERTIFICATIONS V HEREON ARE VALID FOR TINS MAP AND COPIES THEREOF ONLY !F N . NO' 4 61 SAID MAP OR COPIES BEAR THE&PRESSED SEAL OF THE SURVEYOR WHOSE SIGNATURE APPEARS HFJ?EON. NOTE, LOT NUMBERS REFER TO 'MAP OF LAUREL LINKS' ECONIC r FILED IN THE SUFFOLK COUNTY CLERK'S OFFICE ADDITIONALLY TO COMPLY WITH SAID LAW TERM 'ALTERED BY (63/) 765 - 50 f797 MUST BE USED BY ANY AND ALL SURVEYORS UT2IZ/NG A COPY ON NOV. 23, 2001 AS FILE NO. 10712 P. O. BOX 909 OF ANOTHER SURVEYORS MAP. TERMS SUCH 'IVSPECTED 'AND A =•slwK a RA VELER T 'BROUGHT - TO - DATE 'ARE NOT IN COWPLIANCE WITH THE LAW. 1230 AREA = 30,885 sq. ft. 1230SOUTHOLD, N.Y. l/ 02 — 298 � i SURVEY OF �; TOT 18 4-, MAP OF , oa. LAUREL LINKS 1 FILE No. 10712 FILED NOVEMBER 23, 2001 cr \ \\ SII'UATED A 1 MATTTTUCK \\ TOWN OF SOU T HOLD �7 \ SUFFOLK COUNTY, NEW "ORK { S.C. TAX No. 1000-125-04-24.1 1 \� \ SCALE 1"=40' � a APRIL 27, 2006 \ 4y AREA = 30,385.37 sq. e I. 1 s T0.709 1ic OG\ f _`\\ G8 \ X'u�^1�FA L sae g�?G 1 —10 o. 'Q 00, ' /T dG _ d fdn_�,s• 1. ELEVATIONS ARE REFERENCED TO AN ASSUMED DATUM �Zr�T` N EXISTING EtEVATI0N5 ARE SHOWN THUS: SC.i _ S a � a 4��57 �+ / C' , \ �A d0 3 LFP/1p E 2. REFER TO FILED MAP FOR TES HOLE DATA. �Q G!V Fb /i9 t� y+ O / r 'NO OX N 3. MINIMUM SEPTIC TANK CAPACITIES FOR A 1 TO 4 BEDROOM HOUSE IS 1,000 GALLONS. r .'�y_: Ca .PoED i TANK: S' LONG. d'-3" WIDE. 5'—i' DEEP d. MINIMUM LEACHING SYSTEM FOR A 1 TO 4 BEDROOM HOUSE IS 300 sq it SIDEWALL AREA. l T 1 POOL. 12' DEEP. 8' dia. PROPOSED EXPANSION POOL soos ° 40'0 1 \I q el:'a3aposED LEACHING POOL u'��,j� I �aa P� �A ,� - �\ PROPOSED SEPTIC WNK S. THE LGCATION OF WELLS AND CESSPOOLS SHOWN HEREON ARE FROG FIELD OBSERVATIONS AHD/OR DATA OBTAINED FROM OTHERS. 00 g 0 y^/ 0 `C PREPARED laaz F6�coRDa27 survEYs FsrAausrMi� i°a YSUCK Uric+-r" Enr'?Rc ADOPTEDSqATE N 00, �.d N Y-5. Lic. No. d9668 UNAUTHORIZED ALTERATION OR ADDITION ' i, •_,.,-,,.�y� �� • 'r) , TO TH5 SURVEY IS A='-ATON "� =_ G SECTION 7209 OF THE NEW YOR.K STATE" £DUCATiON LAW. COPIES CF THIS SURVEY ILA.- NOT BEARING ���� `� A. ������� -HE'tND SURVEYCWS INKED SEAL OR u g q��7 a of TOBE A SEAL Siff ;:ci 6E coNSl�'-TEED Land �7� �4Y � rh�.7� TO 6E A V:JJO TRUE COPY. ONLY TO IHEs ERSOITED 11,,HOu THE RUN 1 9 ��`� ONLY p RT£ ,NO O FOR S BEHALF TO SURVEY - IS PREPARED, N.'D ON MS TAL AF TO rI-N TITLE;.CfApANY, COVu�IJNENTAL:G?:C", �,ND 7'itla Surveys - .Subdivisions - Site Plans Consfrucfion Laycut TO THE ASSIGNEES OF THE L'OT TR INSTI- rmcN. cEnnFlcAncvs ARE Mar RaNS'1=PAF1: PHONE (639)727-2090 fax (631)727-1727 THE EXISTENCE OF RIGHT OF WAYS OFFICES LOCATED Ai 9411ING ADDRESS I AND/OR IEASEMENTS OWN FOF{RECORDOT .RANTEED. 1380 ROANOKE 4VENUE P.O. Box 1931 c Nerr 'i ork 11901 Rivvrnead. `:ew �'nr. n0 -C 8 _ij SCDHS Ref# RIO-07-0043 LOT 17 VACAA?T SUFFOLK COUNTY€7EPARTME11T OF HEALTH SERVICES r APPROVAL OF CONSTRUCTEDWORKS WC,I-;KS FOR �rKa� A S'1`GLsE- FA 5vy�ELvSt�r�lst:�- 1 e/31y i e/32,5 20- " ®ate SE 20DJ 1 Ref. Na. 20 Sp fPb W. 'ripe sew'are di,7asa? and%vav r s.fg;p y:aci tics of fists locatron have been se f inspsciec!sndlor E;"led by ails O tsart'n t o;other agencies and found to i be satisfacf®rf i"JR,��,t.�,.X!pt��6a��i=�/ BEDROOMS.. '8 p Q, i a � O L � s N Q x� ' !falter J. Hulbert, P.E., ie Office Of Wastewater Management aC. 6/ �CD �"Ve/owe Cv I am familiar with the STANDARDS FOR APPROVAL s AND CONSTRUCTION OF SUBSURFACE SEWAGE �'wrs �' o� of A.DISPOSAL SYSTEMS FOR SINGLE FAMILY RESIDENCES �v �0 Q and will abide by the conditions set forth therein and on the JQ / 94v 1 permit to construct. J ` v A) ��� °=J aN � o� �` CO SURVEY OF PROPERTY e . 30 o zJ , s� AT MA T TI TUCK TOWN OF .SOUTHOLD N. Y. °° s/"��- cis ` •,,'� �s- SUFFOLK ' COUNTY, N. Y. 1000 - 125 - 04 - 24. 11 . h y q �� SCALE 1" 30' SEPT 25, 2002 a9. F 'Q �h AUG. 20, 2008 (ARE4) APRIL 16, 2007 <�ti r, �,\ � SEPT. 5, iREVjS10NS) AUG. 20, 2007 ( FND TN L OC. 1 AUG. 23, 2007 (CERTIFIEA TION)DRYWELL G2o� o AUG 6 2008: (FINAL) ' �m o �� AUG. 13,' 2008 (ADDITIONS) 00 CERTIFIED -TO : ROOF AREA = I = 765 CU.FT �a9 WA TER P. JACOB, 4500 x 0.17 X so.FT 0 V ER SAVING BANK, � . 17651223 - 34VF MPA NA TIONAL TITLE INSURANCE PROVIDE 4 DRY,WELLS 6-0 OR - 91DEEP C �P S 0�110 AREA OF DRIVEWAY ON LOT - 3870 sq.11• ° ��,� 0' ���/`'£cow S C�0F NEW), The locations of wells and cessp00 s�F ASTEjy FRVjC 4 �O ANY ALTERATION OR ADDITION TO THIS.SURVEY IS A VIOLATION R, y �� shown hereon are from field observations AIR F r'-` ME�2 �fr• OF SECTION 720.9 OF THE NEW YORK STATE EDUCA TION LAW. '' C�1 EXCEPT AS PER SECTION 7209 - SUBDIVISION 2. ALL CERTIFICATIONS , V and or from data obtained from others, a ,., ?t,'`li ,,,ya HEREON ARE VALID FOR THIS MAP AND COPIES THEREOF ONLY IF "" S LIC. NO. 496I8 i� SAID MAP OR COPIES BEAR THE iNPRESSED SEAL OF THE SURVEYOR _ WHOSE SIGNATURE APPEARS HEREON. NCi T E, LOT NUMBERS REFER TO 'MAP OF LAUREL L INKS" E p 0 S Y P.C. ADDITIONALLY TO COMPLY WITH SAID LAW TERM 'ALTERED BY • _ FILED /N THE SUFFOLK COUNTY CLERK'S OFFICE - MUST BE USED BY ANY AND ALL-SURVEYORS UTILIZING A COPY f ON NOV. 23 v 2001 AS FILE NO. 10712 (631) 765 1797 � � ,p OF ANOTHER SURVEYORS MAP. TERMS.SUCH 'INSPECTED -AND F A t. ` BROUGHT - TO - DATE 'ARE NOT/N COMPLIANCE WITH THE LAN AREA = 30,885 sq.'ft. o L ,tv /T EET - _ - 02 — 298 2y GENERAL NOTES, !--------------------------------I I i 1 1 SLOPE FLOOR SLAB I 24' CONCRETE APRON' / i i i GIRDER I 1 6' CONCRETE SLAB ON 1 I C I 1 � I I I 1 PROVIDE 6!a POLY VAPOt BARl1IER.----- --- LAP 24'HOL COVER W/4•PEA GRAVEL I � / i i � '9•; i i I I I S Z/ GC TO PROVIDE CUT ON FOUNDATION WALL TO I j Tv2x10 cny>�R`T ACCOMODATE GARAGE DOOR N i FABRIC � �Ti ' 1 I 776yxp6 ALL SLAB�S] I I 11U#1�J1�1 I I 3' PICKETS TOP 6' O.C. ��� 1 i I*pt+lHl?�r�Iz `- -----'1 I 10' RAF SUPPORT BEAM I I ! I I 1 I I I I I I I I I I I I 1 � 4 I trluittrit*Hi I 10' PAST THE POST Id R io , -T-T-r-f-T -T- imirn7rnl ---- --- I NCRETE NOTES, I 1 ALL CONCRETE TO DE 3AOO psL■201 DAYS I i� ' I I ALL FOOTING L$LABS TO Be PO{lilED IM I O I I ! I 1 I ! ! ! I I 1 I IBNOLSTIlttBED/COPACTO POE /SAND x4 POST p I ! I I I I �I ! I 1 I ! I ! ! I I ALL VOOD IN CONTACT V/NOTE I U _ p�� TO BE A.C.O.TREATED W/2 nh Sa' -DOLTS i 'i \i 1 i I i i I� : i i i j ice' I TE of Q 2x8 ACQ FLOOR JOIST 16' O,C, i i i i i i i ! i i i i i i i Q i i i 1 1 P�rmvIDE 6/�a•,ae' L-Dais 4w ad Trn. A 5/4' DECKIN 48 V 1 SLAB■4'TM W Vr LOOWTE E)�JT. 1 � O J IM JOIST I i i i i i i i i i i i i i 44 i i a i i i ------ H (2)2x10 ACQ GIRDER I I I I I I I I z U OLTED TO POST i i i i i_ i_� i ! ! ! ! ! ! !N /8' CARRIAGE BOLT i /Ii I " 1 i l 1 1 1 I I I I I i t U W � ABU44 ADJUSTABLE AND STANDOFF ` ' a -------- ---- ------------------------ I BASE<SIMPSON STRONG-TIE) ONO B --- -- -- - -- - - x10- �- - - - - _J L____ � I A Z S TU --- ITH 4 #4 REBARS 1 _ / l Q v? - Agj pC FTG --- ------ -----------------� ---------------------- ---- -------------------------� r- J Y 6WAY#4 REBARS r i i z ¢ ( ) Lam► I 1' Z —� PA DECK FOOTIN I PROVOIE 6 MIL POLY VAPOR BARRIER 1 I W o?5 CO !— I 1 LAP 24'NIK COVER W/4'PEA GRAVEL 2 DECKING—BENCH—PERGOLA DETAILS W n 1LU11UIL 1 1 I Ld !- ❑ 1 1 I I 44-1-1 a4.1-1 a a I I 3 Q S 1 I ttt❑HttHt Hi I I W <L 1 1 .11-1.�14�.1r01 F® i i Z J O P4 _ I 1 _ ttHttNttHi 1 I Q —� ❑ irnirn7rni 1 1 3 I ' VISTA 1 Baum ROOT FOR ALL NECH IIC ALS RESIDENTIAL DESIGN I MID UTILITES 1 ! V ��� ! NEWE BUR YORK11940 P R ❑ P ❑ S E D 1 ------ --- WF16_65-i------------ ------- -� �� ,M ��'rF A L- 1 r--- - --- O � I / / I / / / / / / / / / T� I I ZSSW FOR CONSTRUCTION DATE, lS'9 1 16'6 1 16' I 4'0 !S - 1 1 I As Ift s FOUNDATION P A N t�- y t -- ----- ---------;--------- ----- -- ---- - -- - --- I n ft D.a 0 B' 4' a' 1 CONCRETE TES, - / / / / / / / / / / / / / 1 ALL CONCRE ALL FQQTTNG1,V-QSTO DAYS CONTRACTOR TO / / / I.MmT1.020/�'� bE F ! scALE 11r-N,-0. i I ALSO PROVIDE Ta BEEAA"TREEAATED v//2 mh ,c2•-Bars s 14328 / PRICE CONSIDERING/ / / SILL PLATE �vmEE s//v xw.-Dais■4a•!aE.TV, THE HATCHED AREA/ / / SLAB 2 4'TKK.W I/r IOOSOTE EV.JT. OF NE�r- I 1 Up AS RAW SPACE clk I I CONTRACTOR TO PROVIDE SILL ANCHORS 5/8'x12 [2] RATED / / / / / / / / / /r -- -------- -----i _____- __ , I ANCHORS E 24' O.C., W/3' SO. SLOTTED WASHER I -------I _______ I I ! Fol I / / / / / / / / / /I,,(' r-- & 6• FROM SILL ENDS AND 12' FROM SILL CORNERS 1 ! - _ RETRO FITTED RFD TITEN HD CONCRETE SREWSEAS ALTERNATE] I I I j 1 V_ . CONTRACTOR TO PROVIDE A MIN, OF 121 BRACED WALLS L41 L------ --------- ------------ 1 PER LENGTH OF WALL LINEIN ACCORDANCE WITH IRC/2000-R602.10.3, _ _________________ _________ BRACED PANELS BE SPACED NO GREATER THAN 25'OC +' Bz LIVING AREA 2 C13RNERS<4FEET,BUT>218 SEE SECTION R602,10.6 77 3989 sq Pt E CORNERS OR OPENINGS( 2'8,SEE SHEARWALL ISIMPSON) SOLUTIONS . OFFICE ` -�-- 3' PICKETS TOP 6" O.C. 24' GENERAL NOTES: CONCRETE NOTES -- - - - - - - - -- - - - - -- - -- - -- - -- - - - - - - - -- 10" RAFTER TAILS SUPPORT BEAM I _ _ _ __ _ _ _ __ _ _ __ _ __ _ __ _ __ _ __ _ ___ . I • A ALL CONCRETE SHALL BE PORTLAND CEMENT, WITH STONE 10" PAST THE POST I , I AGGREGATE COMPATIABLE TO THE DIMENSION I I ALL CONSTRUCTION SHALL I I APPROVED AS NO T ED - OF THE WALLS AND SLAB OF WHICH I I SLOPE FLOOR SLAB -; " THE HE REQUIREMENTS OF THE ' 51u1� THEY ,ARE COMPOSED OF. - � I 1 2' T O F R O N T CODES OF NEW Y RK STq DATE: �� B.P.#3 { B STEEL' REINFORCEMENT SHALL BE GRADE 60� 24' CONCRE�E APAONv. FEE: •r BY: DPR t DEFORMED,WITH WELDED WIRE FABRIC x 4 POST _ NOTIFY BUILDING DEPARTMENT AT WITH A #8 6X6 GRID 1N 4". SLABS, AND I ' I �I 765-1802 8 AM TO 4 PM FOR THE I I I I FOLLOWING INSPECTIONS: . A f8 4X4 GRID IN 6" GARAGE SLABS. w CER�'IFI^ATt��® .* I 1. FOUNDATION - TWO REQUIRED 2x8 ACQ FLOOR JOIST 16 O.C. C COMPRESSIVE STRENGTH FOR STRUCTURAL S/4" DECKIN I i 6' CONCRETE SLAB ON NAILING'& CO"4NECTI0►"'�S I FOR POURED CONCRETE WALLS AND SLABS SHALL MEET OR I M JOIST ( 1 4'A,B,C, EQ�IP'®. 2. ROUGH - FRAMING & PLUMBING EXCEED 3000 PSI @ 28 DAYS. I I 3. INSULATION <2)2x10 ACQ GIRDiER 7 I I BOLTED T O POST I I I I 4. FINAL - CONSTRUCTION MUST D ALL ANCHOR BOLTS, SHALL BE 1/2" - — I I BE COMPLETE FOR C.O. ' ' BOLT I I QCCUPANC ORS ALL CONSTRUCTION SHALL MEET THE PLACED AT ALL CORNERS AND SPACED 04 —0 O.C. S/8 CARRIAGE B REQUIREMENTS OF THE CODES OF NEW CONTRACTOR TO PLACE BOLTS IN A MANNER ABU44 ADJUSTABLE AND STANDOFF ' ' , SE IS UN -AWF YORK STATE. NOT RESPONSIBLE FOR THAT WILL MINIMIZE CONFLICT WITH FLOOR BEAMS.] POST BASE<SIMPSON STRONG-TIE) w I I PROVIDE 6 MIL POLY VAPOR BARRIER - - -- DESIGN OR CONS 10 SONOT4 B BARS I I LAP 24' MIN. COVER W/ 4' PEA GRAVITHOU CER t CONSTRUCTION ERRORS. ALL FOOTINGS SHALL BE PLACED AT A DEPTH WITH 4 # R E I t E 3 36X1 PC FT I I OF 0 UPANC OF 3,'-0 BELOW GRADE AS PER LOCAL CODE. — -- W 1 I H C 4 #4 R'E B A R S t t _ _ _ _ _ DECKING BENCH PER Gn � A DETAILS EACH WAY COMPLY WITH ALL CODES OF F CONTRACTOR TO PROVIDE ALL NECESSARY )VENTS [AS PER CODE], .f. I I RETAIN ORM WATER-RUA! O K STATE & TOWN CODES WINDOW/ACCESS BLOCKING,AND GIRDER SEATS. c� -,:,: _r I I PUBS NT TO SECTION 45-1b AS REQUIRED AND CONDITIONS OF o FOOTIN o i i GC TO PROVIDE CUT FT c TOWN CODE. CON TRACTOR TO PROVIDE A 2" SLAB WITH I .0 O N F O U N D A T I O N WALL T� SOUrHOLD TUV�'N ZBA G H OVER VAPOR BARRIER I I WITH ROUGH SCREED FINIS 0 r°'i ACC❑MODATE GARAGE DOOR L v SOUTHCLCTO'NNPLANNINGBOARD FOR.ALL CRAWL SPACES. I I 6x6 W.W. FABRIC I "�R11111TERSCERTi"i '� I SOUTHOLD TOWN TRUSTEES CONTRACTOR TO PROVIDE A STEEL TROWEL, ' TYP, ALL S7_LB REQUIRcD I N.Y.S.DEC H SMOOTH FINISH FOR SLABS AND GARAGE FILOORS ' I r I I 1 1 I_I I I I_I SLOPED TO DRAIN IF REQUIRED. -1. .!-t--1...G J-..1_..1...1. 1 —_ — — — rl— I I -t t-H-t t-H-t t-H-t `- - - t I t i>a'wtl!"•�3ER CERTlFICATIOAI ALL FOUNDATION WALLS SHALL BE WATERPROOFED I I L n Z L n Z L n O DO NOT PRO EED WITHCXV I t I -t t-H-t t-H-t t-H-t FRAMING UNT SURVEY ERTl�C TE OF OCCUPANCY AS PER LOCAL CODERRIOR TO BACKFILLING I t OF FOUNDATION CATION I f 7 r n_T T-n 7 T-n 7 HA�BE EN APPR VEt?, - - PROVIDE SILL INSULATION AND I f I t SUPP► YY YSTEM CANNOT TERMITE SHIELD TO ALL NEW SILL APPLICATIONS °� ° ° I I C❑NCRETE NOTES: i i EXCE1- /10 OF 1% LEAD, I I ALL CONCRETE TO BE 3,000 p.s.i. @ 28 DAYS I I I ALL FOOTING & SLABS TO BE POURED I I I UNDISTURBED / COMPACTED FINE CRUSH/SAND P U 31NG U (— I I ALL WOOD IN CONTACT W/ CONCRETE I ALL P UMBI G WAST TO BE A.C.Q. TREATED W/ 2 rein. 5/8' r12' J-BOLTS 1 &WA ER LI ES NEE I PER SILL PLATE E'TING BEFO E COVE INGQ I PROVIDE 5/8' x12' J-BOLTS @ 48' O.H. TYP. ,.. I-1- 48• t SLAB @ 4' THK. W 1/2' HOMOSOTE EXPI JT. rl- 0 Q 3/4' PLYWO❑D(SUB-FLOOR) 20 4 t ' FLOO W9 - - - _ L3 Z DOUBLE PLATE 2x6 ACQ 2T8 I ' COMPLY WITH CH TER "4(� z � F— TERMITE-SHIELD ' t � _ _ - _ _ _ _ - _ _� I I SOUTHOLD TO E PCEVENTIC� 3 11-7/8'AJS 20MSR � o FLOOD DAMAGE ( l �\ I I TOWN CODE. I I Q l_J W a I I fY_ Z - - - - - - - - - - - - - - - - - - - - N- / 10'9 \ - - - - - - - - - - - - - - - - - - - -� L- - - - - - - - - - - - - - - - - - - - - - -- - - - - - - -r J Q (� CONRE / -- IN000S BASE NT t - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -�/ �% - — — — — — — — — — — — — — — — — — - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - J N SS OF TH WALL I � E 10.0000THICK E F I CD SOIL Li CD EINFORCED CONCRETE WALL o I I '6 0° z UNDISTURBEDCO U � / / W o ' (/ `� • I I PROVIDE 6 MIL POLY VAPOR BARRIER 18 g ,�#4 REBAR @ ❑C I I AP 24' MIN. COVER W/ 4' PEA GRAVEL GRAVEL - C2 #4 EARS I I L I I W H W CONTINU ONCRETE SLAB ❑ 4 A.B.C. PERFORATE PIPE @ FOOTIN �' � - - - � 6x6 W.W. FABRI CI I _ I I TYP. ALL SLABS I ,A S NDISTURBED SOIL — ' w RE BARS @ 7 O.C. I I I I V�RTICAL - ALLT%RNATE I I I I -t t-H-t t-H-t H ® I o z Q CONTINUOS FOEITIN BENDS IN FOOTIN N I 1 I -rrn7rn7rn o ti 9 FT HIGH BASEMENT WALL I ' ; I I --H-Il-H-f '-HI i I < � o I I I -t t-H-t t-H-t t-H-t I I I '- 7rn� rn7rn-I � i t Note:V/ is the thickness of the wall i• ^ L _J e 2-1 I VISTA ' I I FUR ACE PROVIDE SLEAVES RESIDENTIAL DESIGN 1 FOR ALL MECHANICALS I P.D.B. - 634 t BOILER ROOM AND UTILITES ' REMSENBURG WH CU NEW Y❑RK 11940 Jf= I AJ`O I Y / / / / / / / / / / / / ISSUE FOR CONSTRUCTION DATE in I I P R Ll P [I SED q*l I I d, �[ 1 J J 15'9 I 16'6 I 16'6 I 4'0 1 -- - ----15'3 --_-----_--- ' I I Revisions / � / / � / / -J ---- ---.--------------------_------�------------------------------ -----1--------L--- --- -- --I I I No. Date Description I ' I I I I I I I FOUNDATION PLAN CONCRETE NOTES: i ! 2' 4, 8' 1 I I ALL CONCRETE TO BE 3,000 P.S.I. @ 128 DAYS I I I ALL FO❑TING & SLABS TO BE POURD ❑N - UNDISTURBED / COMPACTED FINE CRUSH/SAND CONTRACTOR TO / / / ALL WOOD IN CONTACT W/ CONCRETIE ALSO PROVIDE TO BE A.C.Q. TREATED W/ 2 Min. 5/�' x12' J-BOLTS I I I _ PER SILL PLATE SCALE: 114" a. V-o" I I / / PRICE CONSIDERING / / / PROVIDE 5/8' x12' J-DOLTS @ 48'! O.C. TYP. I I I SLAB @ 4' THK. W 1/2' HOMOSOTE EXP. JT. ( I THE HATCHED AREA / / / UP I N I I N I I AS CRAWL SPACE / 't i i i I esigned y: Checked Byi I I I I Project Numbed Drawn By: lo ¢ I I - - - - - - - - - - - - L - - - - - - - - - - - - - - - - - - - - - - - - I I Sheet Title- CONTRACTOR TO PROVIDE 'SILL ANCHORS 5/8'xl2 CZ] RATED ' W/3" SQ. SLOTTED WASHER / / / / / / / / / / I - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - y Sheet Numb ;• ANCHORS @ 24 O.C., ' I IiI I I I I I ¢. & 6" FROM SILL ENDS AND 12" FROM SILL CORNERS t _ _ I I I I I I I I t RETRO FITTED RFB TITEN HD CONCRETE ' SREWSEAS lq ALTERNATE) ' ' t S'_6w I I I I a I I I L - / / / / / / / / / / n ' '—lo' ' I I . ' / / / / / / / / / / / / / 1 I ' . o I I I I y� OFN `B�� II I I L- - - - - --- - - - - - - -- - -- - -- - - - - - - -i I F CONTRACTOR TO PROVIDE A IMIN. OF [2] BRACED WALLS ' - - - - - - - _ - - - - - - J _ _ n I I — I - -- - - -- - - - - - - - - - - - - -- - - - - - - - - - - - I PER LENGTH OF WALL LINE IIN ACCORDANCE WITH . IRC/2000-R60 .1 - - - - - - - -- - - - - - - - -- - - - - -- - - AN S .BE SPACED IN❑ GREATER THAN 25'0C 22' 33" 22' LIVING AREA BRACED P EL 3989 sq t ` @ CORNERS<4FEET,BUT>2'8 SEE SECTION R602.10.6 ��� Y @ CORNERS OR OPENINGS< 2'8,SEE SHEARWALL [SIMPSON] S❑LUTI❑NS 7 7' I 24, GENERAL NOTES: . 10'6 3' 10'6 � CONTRACTOR TO MAINTAIN JOB SITE FREE OF DEBRIS GENERAL BUILDING NOTES BY SPECIAL WEEKLY CLEANUP A. DO NOT SCALE DRAWINGS. �., .8. IF THE CONTRACTOR OR SUBCONTRACTOR SHOULD FIND ANY DISCREPANCY IN AND/OR OMISSIONS c� ch FROM THESE, DRAWINGS OR IF THE CONTRACTOR °' ` m SHOULD BE IN QUESTION AS TO, THEIR MEANING r 1 OR INTENT, THE CONTRACTOR SHOULD CONTACT "THE I I -ARCHITECT AT ONCE FOR INTERPRETATION OR t I . CLARIFICATION. USED SHALL BE' EQUAL TO OR Co I I C. ALL MATERIALS I I EXCEED ALL APPLICABLE STATE OR LOCAL CODES I I AND REQUIREMENTS. D. CONTRACTOR SHALL REMOVE PROMPTLY AND LEGALLY I I ALL ACCUMULATED DEBRIS, PROTECT ALL EXPOSED i 'PORTIONS OF WORK FROM ELEMENTS, AVOID OVER I In t- — — — — —— — — LOADING STRUCTURE, AND SECURELY STORE ALL Co ITEMS TO BE USED FOR CONSTRUCTION. ft. THE CONTRACTOR SHALL VISIT THE JOB SITE AND BECOME FAMILIARIZED 22 0 WITH ALL EXISTING CONDITIONS WHICH MAY AFFECT THE BID. NO .. ALLOWANCES WILL BE MADE Al-TER THE BID FOR EXISTING CONDITIONS g I OR THE CONTRACTOR'S FAILURE TO VERIFY EXISTING CONDITIONS. ----22- ------------------------------ ------------------------------------------------------------ F CONTRACTOR WILL PROVIDE BLOCKING TO SUPPORT I I � 1 � cu � I I (h ALL SHEETROCK CORNERS & SEAMS. fill N I 1 r G.. ALL GLASS IN HAZARDOUS AREAS AND ALL GLASSD==* WITHIN 18" OF FLOOR. SHALL BE SAFETY GLASS PER 1991 UBC SEC. 2406. H. ALL EXISTING UTILITIES AND. CITY SERVICES ARE 'TO c BE MAINTAINED, KEPT IN SERVICE, AND PROTECTED I I AGAINST DAMAGE DURING CONSTRUCTION. I I I. CONTRACTOR TO VERIFY LOCATION OF ALL EXISTUNG UNDERGROUND UTILITIES PRIOR TO EXCAVATION. , o 0 J. ALL ELECTRICAL CALCULATIONS AND WIRE SIZE TO BE PROVIDED BY A LICENSED ELECTRICAL CONT CTOR. RECEPTACLE, FIXTURE, AND EQUIPMENT t t LOCATIONS TO BE FOUND ON FLOOR PLANS AND, SITE I I PLAN. CONTRACTOR TO VERIFY LOCATION, FIXTURE N N N I I ' TYPES AND EQUIPMENT WITH OWNER PRIOR TO INSTALLATION I i K. MECHANICAL SYSTEM TO BE INSTALLED BY A LICENSED MECHANICAL CONTRACTOR. VERIFY EQUIP— MENT TYPE WITH OWNER PRIOR TO PURCHASE ANdD 30'9 in ED INSTALLATION. � � � L ALL EXTERIOR DOORS SHALL BE: 1-3/4" SOLID CIORE _ - - - - - - - - - 0 U WOOD, DOORS SHALL BE SELF CLOSING WHERE so 2'7 T10 7'l0 6'3 3' 3'1 z �-- fir. INDICATED ON PLAN. ifH M SHOWER WALLS TO BE FINISHED WITH MOISTURE -- ED RESISTANT GYPSUM BOARD AND CERAMIC TILE (OR - P Z EQUAL) TO A HEIGHT OF 70" ABOVE DRAIN PER 6 9 Q (� 10'9 1994 UBC SEC. 807.1.3. _:___:_____ _I U w N INSULATE DRAIN PIPE AND HOT WATER PIPE UNDER Q U Lj LAVS AND SINKS. ~ � 0 5/8" MOISTURE RESISTANT GYPSUM BOARD SHAUL BE Cl) 2 L CU z 2X6 WALL USED AT ALL WET AREAS PER UBC 4712. 5' EGENCY EXCLAIM 50 GAS FIREPLACE 6 to � Li � � ILI P DURAROCK TO BE USED ON ALL FLOORING OF WET AREAS U CO• Q CONTRACTOR TO PROVIDE NECESSARY ALUM. SEAMLESS GUTTERS & LEADERS L H LLJ 0 1 wW DRAINED UNDERGROUND TO EXIST. CATCH BASIN all O O M U � z �O O O O 3 0 o Li CIL! zo � 2X6 WALL 21 -� VISTA -�� B WET AR RESIDENTIAL DESIGN P.O.B. 5' — 634 ; REMSENBURG , NEW YORK 11940 co ISSUE FOR CONSTRUCTION DATE 0i Revisions M No. Date Description p R [I P [I S E D M —K--y I 03ki15'58'3 7''9 2'6 No y o 0 2X6 WA 4,5 F - IRS 'T FL1111R PLAN =j O 2, 41 8, NCO o � M co SCALE: 114" a II-"0" UP (U Designed Byi Checked By: Project Numioerl Drawn By+ Sheet Titie, CONTRACTOR TOPROVIDE Ny U Sheet Numb _ FOR ALL NUMBERED 7/16' PLYWOOD N or WINDOW & DOOR ASSEMBLIES IN Cr) COMPLIANCE W/ IBC CODES N 2X6 WALE f ce) I _ .!a o a R I I I S' T 432 _431` CONTRACTOR TO MAINTAIN JOB SITE FREE OF DEBRIS tc- 6'9 8'6 " -- 6'9 6'9 5'2 '11 2'8 2'8 2'I 5' 6'9 6'9�}�I'9'i�6'9 6'9--�1 T'Q�� OF NE°' I. A WEEKLY CLEAN—UP 22' lll'il ( 9'4 1119 J 816 ' 13'6 BY SPECI L r ( 77' J y 6' GENERAL NOTES: , 'TIMBERLINE (30) ASPHALT SHINGLE y CHARCOAL GRAY (2)15# FELT TYP. 1/2' CDX SUB—ROOF • r: 2x12 RAFTERS @ 16' D.C. • UNLESS OTHERWISE NOTED � /4 AZEK KEYSTONECT P>, TIMBERLINE C30) TIMBERLINE (30) E ASPHALT SHINGLE ASPHALT SHINGL CHARCOAL GRAY CHARCOAL GRAY (2)15# FELT TYP. 12 _. (2)15# FELT TYP, 1 1/2' CDX SUB—RO 12 1/2' CDX SUB—ROOF --14 TIMBERLINE C30) 2x8 RAFTERS @ 1 ASPHALT SHINGLE s. 2x12 RAFTERS @ 16" D.C. UNLESS ❑THERWIS 12 CHARCOAL GRAY UNLESS OTHERWISE NOTED (2)15# FELT TYP. 1 1/2' CDX SUB—ROOF ' � COPPER FINAL -- — 1 2x12 RAFTERS @ 16' O.C. 30 -7 UNLESS OTHERWISE NOTED MASONRY CHIMNEY — — — W/ BRICK VENEER l r 4 _ — 1_61 ZEK FASCIA AZEK BEADED SOFFITS r. ROVIDE C❑NT.VENT t 1 " n ® J. W/INSECT SCREEN TYP. 7 RYVIT SYSTEM 2) 15# FELT /2'CDX SHEATING i x6 STUD WALL s R-19 BATT INSUL.TYP. - -- - - -- - - - - - - - - - - --- - - - - - - - - - - - - - - - -- - - - - - - - - -- - -- - - - - - - - - - - - - - - - - 1/2'GWB W/3CTS SPACKLE 0 NIII 1 11111 11111 11111 11111 11111 1111,9411111 E 11111 11111 11111 11111 11111 1111iffi= 2 !E�w LINO= ED mill ,wljjll��Jjg gal I � Q w 0 Q 'E 1 O ELEVATI - 2. 4' 8 Q �- -J U � - TIMBERLINE (30) W o6 SCALE: 114" 1'-0" ASPHALT SHINGLE Q z CHARCOAL GRAY (2)15# FELT TYP, � H N � n/ � I- w 1/2 CDX SUB—ROOF k LLJ o f. 2x12 RAFTERS @ 16' ❑.C. , W E— CL UNLESS OTHERWISE NOTED 12 Z Q 1 Q 12 COPPER NA � 4f - 3 - _ VISTA RESIDENTIAL DESIGN P.O.B. - 634 REMSENBURG TRAY CEILING LEVEL @ 12'01 F.F. NEW Y❑RK 11940 ISSUE FOR CONSTRUCTION DATE F 5'-4" — Revisions 1 1'—6 —STUCCONo. Date Description TOP WINDOWS @ 6'8"F.F. DRYVIT SYSTEM TUCCO� 1 444 � � � � DRYV SYSTEM ` 1/2'CDX SHEATING C 1 FELT 1 j 2x6 STUD WALL " 1/2"CDX SH TIN 6 -8 2x6 STUD WALL R-19 BATT INSUL.TYP. 1/2'GWB W/3CTS R-19 T SUL.TYP. 1 PACKLE 1/2'GWB W/ TS SPACKLE 1 _ _ _ FIRST FLOOR —FLOOR @ 0'0' - - — — — — — - — — — — — — ——- -- - - - - --- - - - - - - - - - --- - -- -- - - - -- - - - - - - - — esigned y+ Checked By: TM Project Nunberi Drawn Byi 411111 ee i e 4 . Sheet Numb r AR A 41P R [I P [I S E 'D SOUTH ELEVATION frr C� O i k < D 2' 4' b' 1Q3 6 4pQ� , T4�E OF NE�d { SCALE: 14" = I'-O" s i a R •.:T. . ... a ..- .. - - .. _ ., . r TIMBERLINE (30) GENERAL NOTES ASPHALT SHIfNGLE CHARCOAL GRAY C2>2x12 RIDGE (2)15# FELT TYP. _ TIMBERLINE (30) ASPHALT SHINGLE 1/2' CDX SUB-ROOF __ :�--_____ x CHARCOAL GRAY 2x12 RAFTERS @ 16' O.C. �saa -�ssarzrzsiai-aisz— TIMBERLINE (30) (2)15# FELT TYP. UNLESS OTHERWISE INOTED =__=_=_=_= --------------- um ASPHALT SHINGLE - - -- � �JZ.Ct_'1.R-.r'\.IItJ-itPA 1/2' CDX . SUB-ROOF C2)2x12 RIDGE _ ------ ------_--- - - - ------- CHARCOAL — ---= —_= ---- — ---------- ---_— ❑ L GRAY C2)15# FELT TYP. 2x12 RAFTERS @ 16' O.C. ____ — --- — — --- --- __-- UNLESS OTHERWISE NOTED _=_`___________:__-_____ __ _ __ _ _ _ _ _ 1/2' CDX SUB—ROOF —_--- =____—--=_---____ _—=_=—_===_=— 2x12 RAFTERS @ 16' O.C. ---— -----------_—= — _--_--_ --_------------_—_ — UNLESS OTHERWISE NOTED 12 =_========—�==—____= =-==t== = _ COPPER FINALE -__I_III- __—-_-_-_=_ —=-_-=_ - - — —II—'I---i--4 — . -eiim 1 i I I I �I I I I I I .I III I I • 11 IIII I I � 1 I' 1 � . I — II I I ill II III i I n I III I I p I Iil I I I I 1 I I S I — . IIII II II + III i I I IIII II ' I 1 � S I I 12 111, � 1 ( III I II I I11 I II1 I I 111 1 1 1 I 12 4f P Z E K FASCIA r STUCCO y DRYVIT SYSTEM —�-- AZEK BEADED SOFFITS (2) 15# FELT R❑VIDE CONT.VENT 1/2'CDX SHEATIN W/INSECT SCREEN TYP, r FM . . . . . . . . . . . . . . . . . 2x6 STUD WALL I R-19 BATT INSUL.TYP. p I 1/2'IGWB W/3CTS SPACKL �Jcp YY - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - -- - - - - - - - - - Q o 0 z U = W E] PROPE SED E A S ELEVATILIN Q Z Q � O 21 4' e' -1 U w �4 (2)2x12 RIDGE TOP RIDGE OV DINING/KITCHEN W p6 co f-- � AREA @ + 278'F,F. Q z s MASONRY CHIMNEY SCALE= 114" a 1'-,0' W ` TIMBERLINE (30) W/ BRICK VENEER _ _ ASPHALT SHINGLE TIMBERLINE (30) 6'-9' 3 W I— _ - CHARCOAL GRAY ASPHALT SHINGLE Lif-- '--- <L (2)15# FELT TYP. CHARCOAL GRAYED C2)2x12 RIDGE GARAGE RIDGE pq 1/2' CDX SUB-ROOF (2)2xl2 RIDG 12 @+ 20'I T ' 11' F.F. Q 2x12 RAFTERS @ 16' O.C. SKYLIGHTS 5 1/2' CDX SUB-ROOF 2x12 RAFTERS @ 16' O.C. 3 UNLESS OTHERWISE- NOTED • 12 UNLESS OTHERWISE NOTED I S T A RESIDENTIAL DESIGN 12�4 — 29'_3' REMSENBURG NEW YORK 11940 12 — ISSUE FOR CONSTRUCTION DATE 4r N Revisions r EK FASCIA TOP WALL @+ 9 0 F,F, p AZEK BEADED SOFFITS No. Date Description ROV E CONT.VENT j W/INSE T SCREEN TYP, TUCCO DRYVIT SYSTE k ® <2> 15# FEL t 1/2'CDX SHEATING Tm 2x6 STUD WAL ' O LEVEL�. R INS L.TYP. - - - - - - -- - - - - - -- — - - — - -- - -- - - - - -- — -- - - - - -- - -- - - - - 1 B SR --FIRST FLOOR —FLOOR @ 0'0' ---GARAGE FLOOR @ —1'7' F.F. esigned yj Checked Byl i ' MEWPROVENCAL DDOR N0. 41686_PROVENCAL DOOR N❑.41686PROVENCAL DOOR N0.41686 ro,ject ur,ber+ DraNn Byl DESIGNER DOORS DESIGNER DOORS DESIGNER DOORS heet itle lu 'heet Nurlb ioR�v AR NjrF PROPOSED WEST EL. EVATI [IN x r l c— - $ „ �r ML .S pq I•f O F \,�� SCALE: 114' = I'-O" �MECHANIC�kL SPECIFICATIONS GENERAL NOTES 1 1. SHEET METAL WORK: DUCTS SHALL BE FABRICATED FROM ZINC COATED ELECTRICAL SYMBOLS IRON OR STEEL CLASS "0" OR "I"' (IN ACCORDANCE WITH UMC.) I I r. I r - - -- - -- - -- - -- - - - - - - - -- - - - - - - - - - - � i DUCTS SHALL CONFORM TO DIMENSIONS ON THE DRAWINGS UNLESS LOCATION OF STRUCTURAL MEMBERS PROHIBITS. . VERIFY WITH 3D 12NMPLEX OUTLET DF00RA 120V DUPu'�ouRrT-s+AT�,oh[sroe ARCHITECTURAL AND STRUCTURAL. DRAWINGS PRIOR TO FABRICATION. 1°"01Q2°7°0-aw I I I I � i I I I 2. ALL DUCTS SHALL BE SUBSTANTIALLY SUPPORTED WITH HANGERS TO THE 6� 7MREfEPTCZOEOlU STRUCTURE. DUCT SUPPORT SHALL BE PER UMC 1004 AND TABLE 10-E. CEILK FAN HAMPTON DELTA 52' I I t 3. DUCTWORK SHALL INCLUDE A NECESSARY VOLUME SPUTTER OR IF I TM�- oA I t I I i r. BALANCING DAMPERS AS INDICATED ON THE DRAWINGS OR AS REQUIREDn �OUMDFA"1Td' "'�1P1°` I I r - - - _ - - _ - ' N[ TROL OF THE VENTILATION SYSTEM. C...- SURFACEMWEDMt. $ 1 I- FOR PROPER BALANCING AND CO 1 uart swm�oFcaRA 1, 4. PROVIDE TURNING VANES ON ALL SQUARE ELBOWS — BOTH SUPPLY AND $� TRU-wYUMTsM70iMCMA I I I I RETURN DUCTS. =T SYMPLIMT ¢ DIWER SWWA MCMA I I I 5. PROVIDE AIR BALANCE REPORT VIA INDEPENDENT AABC CERTIFIED I I 1 I z cu:crmc FANQ � En+Aust FAN�1[AIER�uort CONTRACTOR TO INSURE MECHANICAL EQUIPMENT IS OPERATING AT 9'01�OT0i DESIGN CONDITIONS. DUCT INSTALLATION IS TO BE COMPETE AND FREE OF ® I I I I N7ERICR WALLscam AIR LEAKS, DIFFUSER, GRILLES AND REGISTERS ARE PERFORMING AS SHOWN ON DRAWING. sa�Mt��sEcaa+ �� 6. DUCTWORK IN ATTIC SPACE ' SHALIL BE LINED WITH 2" FIBERGLASS INSULATION. O cu+ ,�o�oaocoF�c,oR D T.V./ca`E T10N i I I 1 LINE RECTANGULAR. SUPPLY DUCTWORK WITH 1" THICK FIBERGLASS I I I i ` INSULATION BELOW ROOF. OPTION: FIBERGLASS DUCTBOARD 0 RCS nWED ME ROAM INSTALLED IN ACCORDANCE WITH SMACNA STANDARDS. RETURN L - - - - - - - - I DUCTWORK SHALL BE LINED WITH 112„ THICK DUCTLINER. EXCEPTION: © DOORoH I I I I I I WHEN DUCT IS LOCATED IN CONDITION SPACE IT SHALL BE LINED UP I I TO 10' FROM HVAC UNIT. I I I I 7. VERIFY MOUNTING OF ALL MECHANICAL EQUIPMENT, GRILLES AND I 1 ELECTRICAL SYMBOLS REGISTERS, DIFFUSERS, DUCTWORK, PIPING, ETC. PRIOR TO I I i PURCHASING MANUFACTURING AND INSTALLATION. I I I I 8. ROUND FLEXIBLE DUCTWORK (INSULATED) MAY BE USED AS SHOWN ON THE DRAWINGS IN LENGTHS NOT 'TO EXCEED 8'-0". 1 I I I - - 9. ALL DUCTWORK SHALL BE INSTALILED PER THE LATEST SMACNA MANUAL I I I I UMC CHAPTER 10, AND SHALL BE CLASS "0" OR CLASS T. I I I I 10. I I 11. ALL-INSULATION, MATERIAL, COVERINGS, ADHESIVES, VAPOR BARRIERS I I I AND TAPES SHALL CONFORM TO iNFPA '90A, FLAME SPREAD CLASSIFICATION I I i I NOT TO EXCEED 25 AND SMOKE IDEVELOPMENT NOT TO EXCEED 50. 1 I 12. ALL MECHANICAL AIR DISTRIBUTION EQUIPMENT SHALL BE HUNG AND/OR I rl- SUPPORTED IN A LEVEL POSITION UNLESS SPECIFICALLY NOTED OTHERWISE. I i I I VIBRATION ISOLATORS SHALL BE UTILIZED TO INSURE FINAL EQUIPMENT I I INSTALLATION PRODUCES A MAXINOUM OF 45 dB ABOVE CEILING. I I I I 13. MECHANICAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL I I sa CONNECTIONS TO MECHANICAL ECDUIPMENT BEFORE ANY ELECTRICAL I I r- I CONNECTIONS ARE LOCATED FOR MECHANICAL EQUIPMENT. I I I �i- 14. BID MECHANICAL SYSTEM AS FOLLOWS: I i I I M I A. COLD AIR SYSTEM WITH INDIVIDUAL CONTROL - I I I I-'--I . B. HOT AIR HYDRONIC SYSTEM WITHI INDIVIDUAL CONTROL - I I I 15. *DESIGN CONDITIONS - MAINTAIN 70 AT MINUS 15'. F 'DESIGN CONDITIONS - MAINTAIN 70' AT PLIUS 95• I I I I I I I i p I 1 lip L- - - - - - - - - a I I LD U I I H I I I I z - - - - - - - - - -- -� I I I I LP 3 ( 1 —� �— LLJ - - - - - - - - - -� / \ -- - - - - - - - - -- - - - - - -- - - - - - - - - - - - - - - - - - - -- - - - - - - - - I �L_ (— / \ -� -- I / \ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - J J - - - - - - - - - - - - - - - - 1 �- _ - - � GARAGE_ �_­l Z Q U W w F - - - - - - - - - - - - I STI] RAGE � i PR [] P , [IV , I-- I U PW4 ELECTRICAL PLAN Q c z i I i I � ►�--t . 1, i O �� 4, b� 24 I Iwpm t ( so 1 I Eo L �— �— CL I i I I I I SCALE: 114" = 1'-0" z E A4 I I I Q I i I I I I I 4'11 14'2 4'11 o L_ _ _ _ 1 J-1 0 V1S T A 1 I i o o � I FUR ACE I RESIDENTIAL DESIGN 1 -0- BOILER ROOM - I I P.D.B. — 634 i WH 1 1 REMSENBURG I I NEW YORK 11940 I r i L 1 I ICUISSUE FOR CONSTRUCTION DATE + 1 I I I N Revistons I i 1 1 ru No. Date Description 1 1 I 1 I I 1 I I I I 1 0 I I I I CU i I I I i i lip in 1 I I i UP 1 +; Designe By: I r- - - - - - - - - - - - - - - -- - - -- - - - - --- -- - - - - - - - - - - - - - - - - - - - - - � v t I I Project Numbers DrawneB By: I I I 1 I I I I I ISheet + e- . F [IUNDATI [IN i I I I i I I I I I R hi Sheet Numb I I I 1 6 IL— LECTRICAL P -LAN UP r T 1 I 1 T tip I I ! 1 i I i I O 21 4 89IL - - - - - - - - -- - -- - - - - -- - - - - - - - - --il I IL- -- - - - - I I U oQ IA L - - - - - - - - -- - -- - -- - - - - -- - - - - - - - - - _ _ L-- - -- - - - - - - - - - - - - - - - - - - - - - - -- - - - - --� M SCALE, 114" = 1'-0" q. LIVING AREA 3989 s f t U' 00 -- .---- 7 7' MECHANICAL SPECIFICATIONS 24• GENERAL NOTES. >. F WORK: DUCTS SHALL BE FABRICATED. FROM ZINC COATED 10'6 3' 10'6 1. SHEET METAL IRON OR STEEL; CLASS "0" OR 001 (IN ACCORDANCE WITH UMC.) DUCTS SHALL CONFORM TO DIMENSIONS ON THE DRAWINGS UNLESS LOCATION 'OF. STRUCTURAL MEMBERS PIROHIBITS. VERIFY WITH - - ARCHITECTURAL AND STRUCTURAL DRAWINGS PRIOR TO FABRICATION. 2. ALL DUCTS SHALL BE SUBSTANTIALLY .:SUPPORTED WITH HANGERS TO THE STRUCTURE. DUCT SUPPORT SHALL BE PER UMC 1004 AND TABLE 10-E. 3. DUCTWORK SHALL INCLUDE A NECESSARY VOLUME SPUTTER OR �' CISCIS BALANCING DAMPERS AS INDICATED ON .THE DRAWINGS OR AS REQUIRED � r- FOR PROPER 'BALANCING I I AND CONTROL OF THE VENTILATION SYSTEM. 4. PROVIDE TURNING VANES ON ALL SQUARE ELBOWS -- BOTH SUPPLY AND i I { RETURN DUCTS. 5. PROVIDE AIR BALANCE REPORT VIA INDEPENDENT AABC CERTIFIED I I CONTRACTOR TO INSURE MECHANICAL EQUIPMENT IS OPERATING AT 0D I I DESIGN CONDITIONS. DUCT INSTALLATION IS TO BE COMPETE AND FREE OF AIR LEAKS, DIFFUSER, GRILLES AND REGISTERS ARE PERFORMING AS r. I I SHOWN ON DRAWING. 6. DUCTWORK IN ATTIC SPACE SHALL BE LINED WITH 2" FIBERGLASS INSULATION. I I LINE RECTANGULAR. SUPPLY DUCTWORK WITH 1 THICK FIBERGLASS I I INSULATION BELOW ROOF, OPTION: FIBERGLASS DUCTBOARD I I INSTALLED IN ACCORDANCE WITH SMACNA STANDARDS. RETURN I DUCTWORK SHALL BE LINED WITH 1/2" THICK DUCTLINER. EXCEPTION: 0° WHEN DUCT IS LOCATED IN CONDITION SPACE IT SHALL BE LINED UP 22' Hr 0 y TO 10' FROM HVAC UNIT. 7. VERIFY MOUNTING OF ALL MECHANICAL, EQUIPMENT, GRILLES AND - - - - - REGISTERS, DIFFUSERS, DUCTWORK, PIPING, ETC. PRIOR TO GARAGE I - - - 9 PURCHASING, MANUFACTURING AND INSTALLATION. �3" X 3 ' I i 8. ROUND FLEXIBLE DUCTWORK (INSULATED) MAY BE USED AS SHOWN ON ____________________22--==___=----=__=____=--' I i NOT TO EXCEED 8'-0". N THE DRAWINGS IN LENGTHS '� I I � 9. ALL DUCTWORK SHALL BE INSTALLED PER THE LATEST SMACNA MANUAL `r I I cu UMC CHAPTER 10, AND SHALL BE CLASS "0" OR CLASS "I". 10. 11. ALL INSULATION, MATERIAL, COVERINGS, ADHESIVES, VAPOR BARRIERS AND TAPES SHALL CONFORM TO NFPA. '90A, FLAME SPREAD CLASSIFICATION w OPMENT NOT TO EXCEED 50 NOT TO EXCEED 25 AN'D SMOKE DEVELL . I I . ' I 1 12. ALL MECHANICAL AIR DISTRIBUTION EQIUIPMENT SHALL BE HUNG AND/OR SUPPORTED IN A LEVEL POSITION UNLESS SPECIFICALLY NOTED OTHERWISE. VIBRATION ISOLATORS SHALL BE UTILIZED TO INSURE FINAL EQUIPMENT Q` INSTALLATION PRODUCES A MAXIMUM (OF 45 dB ABOVE CEILING. all 13. MECHANICAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL _ _ _ _ _ _ _ _ CONNECTIONS TO MECHANICAL EQUIPMENT BEFORE ANY ELECTRICAL h p CONNECTIONS ARE LOCATED FOR MECHANICAL EQUIPMENT. V r - o o 14. BID MECHANICAL SYSTEM AS FOLLOWS: A. COLD AIR SYSTEM WITH INDIVIDUAL CONTROL - N ru rdI i B, HOT AIR HYDRONIC SYSTEM W H INDIMIDUAL CONTROL - 15. *DESIGN CONDITIONS - MAINTAIN 70' AT MINUS 15". I 1 U *DESIGN CONDITIONS - MAINTAIN 70' AT PLUS 95*' , 1 I I E 30'9 I i U = 7'10 7'10 6'3 3' 311 Z �-- ' 3 �l U 19 Q -0- P 10'9 I ®4 AMP LECTRIC PAN � � -- -.- ' `FI �E • U W C TINUOUS UNDER-CABINET -0 u Cu z � X 5 POWER STRIP 6 LJ OV � �- - -�- • o z ( M W o BUILT—IN FLAT PANEL TV o o W (_ Q -0- �F-k JRE FAN PR [IFI [ISED FIRST F 11R VISTA L2,1 � , --\/ TR ICAL PLAN ELEC 1 51- CHANDALIER RESIDENTIAL DESIGN - WEBAR DESK P.O.B. - 634 O 2' 4' 8' '� �, $ _ REMSENBURG —DUTCH PANTRY 0 i� NEW YORK 11940 L-- HANDALIER SD ISSUE FOR CONSTRUCTION DATE SCALE: I/4" = 1'—O"L crt �� Revisions M 6F==� No. Date Description 61 o :D 0 15' 8'3 7'9 2'6 M cu -(�- -�- -�- o 4'5 _\ D Co in O � SD y ZLI LKJ { ELECTRICAL SYMBOLS (I. LIER R � 12o1v"LEK OUTLET DECORA T D' (U WITMER 87780-C1N 120Y WPM OUT XT-SNITCH ONE SIDE 221DVRECEPTACEOECORA Designed y: Checked By= CERM PAN HAMPTON DELTA S2' � NE)AI►HErt-PROOF E>ta05vl>E MMORA Project Number, Drawn Bye yr �I (R(OM FAULT CRTCRT INTERRIPTER SD Co a - 0- SURFACE MOUNTED EXT."CE $ TJGHHT SRITCN DECORA .�Q. 1!) TFHRIEE—N'AT UCHT SINICH DECORA ,� r'rt SD r �--- UNDER—CAlxNET $' "IIIITT Sheet Title, FLUORESCE STRIPJGK DAMA R SNTTCN DECORA R1 b 1 M N Meet Numb � ELECTRIC PANEL EXHAUST DUCT FH71 RANCE � ,y I $$ -(T} 1 ) N sww DEIEm y I .0 RIIERIOR MALL SCONCE , Tr ENTRANCE SECTION/METER N dO CARBON MONOJR'JE DETECTOR TTW / Y cLu V-D RC v LY.I CABLE CONNECTipt ORECESSED FIRRM TUBE RADIATOR TELEF110NE C) -. HXIITSDE smCKET Q HH� DOOR CHIME tl O L F- Dom BELT IV v 6 :' �---69 86 69 69 52 11 28 28 21 5 69 69�}c19�}c69 69� �a ELECTRICAL SYMBOLS ' ia3 -L E - � 22' � 11'11 � 9'4 I 1119 � 8'6 �I 13'6 o � sJ. 77' J son Strong-Tie Company,Inc - - - -- - - - - -- - - - - -- --- - - - - -- - -- - -- - - _ GENERAL NOTES HANGER LIST- . Sim 24' P 9 _ B1 SQUASH BLOCKS AT NTERIOR GEARING gSQUASH SOCKS AT CONCENTRATED LOADS A3 TRUS�ISTYOU IW�..�,�.��,��,w� RIM BOARD CLOSURE Plot Plot ID Q_Y. Product Label Top Nails Face Nails' Member Nails Notes 1 TM IN" i at+e,wj.•sm if IIit IiI - - — — —— — — — — — — — —— — — — _ — — — — — — — — — .d e°d "" '""h r 16-40 6-NIO (2) .w eo. . Hl 3 U3512-2 H2 3 IUS2.37/11.88 10-NIO H3 2 HUlt 22-10d 6-N10 SLOPE FLOOR SLAB H4 2 HU11 22-10d 6-N10 G' TO FRONT HANGERNOTES 24' CONCRETE APRON— iIII 1III ION- — IIIIII I'III1�1 1'IIII��I III'III�I 'IIIIII 'I1IIII 'IIIIII 'IIIII1 ItIIII I'III�II �►IIIIr�I rdY/IIIIId e�d tI'IIIII I'IIIIII I'IIII1I IIIIIII IIIIIII 1II'IIII III1II(II1(IIIIIItI,I III1IIIIIIIIIII,I I,1II1IIt(1II,III — —— — — —(2) Web-Stiffeners' Required JOIST AIND BEAM LIST WillPliesPlot ID Length Product ? ) atin e+ " vch 6' CONCRETE SLAB ON 46' 11 7/8'TJI560 JOIST 1 41 1A46 eetyM A40 40' 1t 7/8'TJI560 JOIST 1 4 A. A26 26' 11 7/8'TJI560 JOIST t M at d to sy +Wd+�+�w doi� A Al2 12' 11 7/8'TJI560 JOIST oe pa'' ''+n°^'""' ' `"" ;"d hm� gb' .i,. A42 42' 11 7/8'TJI560 JOIST of M0 W.Wd Ind 10 �ifIWO M1 18' 1 3/4' x 11 7/8' 1.9E Microllam LVL M2 4' 1 3/4' x 11 7/8' 1.9E Microllam LVL P1 22, 5 1/4' x 11 7/8' 2.0E Parallam PSL ------------------------------------------ -j3'-------------------------------------------------- ----- PROVIDE 6 MIL POLY VAPOR BARRIER c- - - — — — — — —-—-—-—-—-—-—P2 7' x 11 7/8' 2.0E Parallam PSL LAP 24' . PEA GRAVEL Normal O.C. Spacing 16' : ------------------ 20'-1 '------------------ ' -------10'-S --------�-------10'-5 -------- -------10'-5 -------�-------10'-5�-------7�-------10'-6 --- ----- 1 r - - - - -- -ACCESSORIES LIST TimberStrand LSL ---_----------_ -—-—-—-—-—-—-— Rml 16' 1 1/4' x 11 7/8' 1.3E Bkl 1' 1.7' 11 7/8, TJI 560 Blocking Panels 4' 7' 11 7/8, TJI 560 Blocking Panels GC TO PROVIDE CUTBkl ___-- �EEBk2 11.4 11 7/8 TJI 560 Blocking Panels 1 I IC2)2 10 PCQ II , I I I I 1 I ON FOUNDATION WALL TO Bk2 i' .75' ll 7/8' TJI 560 Blocking Panels -Stiff 1 I I I I I I ACCOMODATE GARAGE DOOR wbl 8.88' wvood Edge Gold (24' Span Rating) 1' Web Sh1 4' x 8' 23/32' Strucr Bkx , Random length blocking panel cuts 6X6 W.W. FABRIC rIIrI''� --I,1I Bk, Btoking Panels; Rm, Rim Board; Pc,Paratlet (Closure TYP. ALL SLAB NAILING REQUIREMENTS 4 J- - -I J- - I - 1 -tt-H-tt-H-ttHI — — — — — — TJI Joist at bearings Two 8d (2% " box nails (1 each side), 1 zznZLnlzns I J1. 4-u-44-u� 4-u-4 1 lIIIIIIII,III — — — — CD minimum from end. I ICs ttH-ttHttH- nr T r r — — — — — o kr`'4t'Ir}•arf;Ck��,', •~.'' ., • ' . ' "" -—I IIIIIII I II 1I'ItI II1(1 II IIIl— -- IIIIIII I II I I'IIII IiI 1II1(III I --IIIII►IIIt IIII I 1II1 III 0�d�jII+�IIIIII II Ii I,I,1I S 1�=,I--Ii;I'ItI1 II II II i1'�A1IIIIIII-3-.I1I1I►IIII�I—I1IIIII1lt---IIII:II1 I1II"I'II,I1I 1II—1�I1llIIIIII---IIII III1I'II IT—(1llIIIIII I --IIIIII�'1tI'IIllIIIII'II--IIIIII'I IIII'rI1llIIIII II—-�IIIIII'II'1 I1I Ir1llI1III II--�--II1II'I('II II�r(1l1II1I!I I1�:„t;1;,I;�I I, I1,;:l1;,I;�II�-1IIII1I tI''I IIII IIl111IIIIt(---IIII IIIIII-t III II't IrIIIIII1II(I—-III1I-IIIII I'II'I IIII �(IIlIIII!II--�IIIII IIIII I 1tI'1('-�IItIIIl!I(I ',I;,�(Ii,,I!(1 I IIII►IIi�III I(lIIIt(III -j(III IIIIIIIIIII1I IIIIIIII III--IIIII IIIIIIIII1 I III T IIIIIIII III�--IIII IIIIIIIIII1 I II( 11I1II'�II1,lI 1III1II1 IItI1IItII�11IIIIIII!I I _.— —II1I1I1II1i1IIIII1I1I1III1II I --1I11I,1III1tIIII1I1III 1II I —Blocking panels, rimjoist oir rim board to Ibeanng plate: - 1 Od (3") box nails at 6" o.c. N T ( i2ol �cREJI Blocking panels or CONCRETE NOTES: TJI Joist rim board: Toenail with 10d 3" box nails at 6" o.c. or I I X I I I ALL CONCRETE TO BE 3,000 p.s.i. @ 28 DAYS 16d (3/") box nails at 12" o.c. ALL FOOTING & SLABS T❑ BE POURED ON I1I I;1I,I i,I,1,IIlIIII� — , III I II R��c Fo �k OL(IQQ(Z3�—��i �QULLZ—� Shear transfer. Connections equevalent to-decking nail schedule. UNDISTURBED / COMPACTED FINE CRUSH/SAND Rim board, rim joist or closure to TJI joist;' ALL WOOD IN CONTACT W/ CONCRETE 1/."width or less: Two 10d (3") box nails, once each top and bottom om flange. TO BE A.C.Q. TREATED W/ 2 rin. 5/8' r12' J-BOLTS , PER SILL PLATE 21-"trhu 2/� width: Two 16d (31") box nailst,one each at top and bottom flange. PROVIDE S/8 x12• J-BOLTS @ 48 0.G' TYP. s ~� 48� SLAB 4• THK. w 1/2• H❑M❑soTE EXPI JT. �I 3%wwidth: Toenail joist to rmjoist with one 110d (3") box nail each side of joist top flange. 0 Kn 2x4 minimum squash blocks: Two 10d (3") box nails,one each at top and bottom flange. 2b'4 I 24'8 I —A3 ti ' - --FLDDR)/4' PLYWOOD( A2 < 10 DOUBLE PLAT L - - - - - - - - - - - - - - - - - - - - - - - - - - - -- ERMITE-SHIELD 11-7/8AJS 20MSR - - - - - - - - - r - - - - - - - 1 - - - C S C — MEMO= - OA aC� I ULi in '6 z RS CO R CJCONTINUOUS I �BB�ST I P OV#DE MI zrM x10.000OTHICKN , E SS ❑ WAL L�P -4 N. OVR 41 PE G AVII 1 NF❑RCED CONCRETE WALL LiUNDIST RBED SOIL PROVIDE 4 SLAB F/PROPANE TANi'S 5 1/4rx ll f/8r MIICRIDLJM �.VL g #4 REBAR � _ Rs Li nGRAVE 2 REBA ONTINUC ❑NCRETE SLAB O 4 A.B.C. ! ALL ONC( ETE� TOIBE �3,00 p.�.l.8> E PERFORATED PI E C! FOOTIN N AUL F OTI G SL BS TO E ROUR D N IDl V �E I I C QI It t 1 I I I I NNC IOOS , 'A ' CO� � / � NDISTURBED SOIL AL I bL OOi/CNd.JdI� A I I N1S O.C. LTS AS, PER MAN.SPECSR ARS 7 N BENDIN FOOTN PCOVPDE /8� x12` J-61- SVERTL RNATE J�l 48 I D.CI TY . I I " I 1 1 1 1 1 1 1A AL CONTINUOS FOOTN A9 FT HIGH BASEMENWL 21 SAB '@ 4' THS. W' 1/2' HDMOSTE LXP.IJT. I I I VISTA RESIDENTIAL DESIGNI PROVIDE SUEAVES I NoteW is the thickness of the wall OAL M CHA ICA S P.O.B. - 634 A3 I VH B1 REMSENBURG BI NEW YORK 11940 I 1 71'x18' 2.00 PAR LL -► ISSUE FOR CONSTRUCTION DATE PR :° Revisions6 A 1 16 6 1 I I ' 1 1 1 I 1 1 1 11 1 i 16 6 1 11 1 1 1 1 I > 3 I I I I I 31 1 1 6Imo � II? -- -- -- -- --- ----- - -- No. Date Description `o 7-- - --1-7-116 FIRST FLOO R AND I- � -1 Q I I IJ IIIIIIIIIII tH-t H-t 1 T_ -r n � -_ 4 a- D E C -K . FRAMING -rrn1 � r -r r r 1 � e'o 4' UP 0 A261 ICUICUMP SGALe: I/4" 1'-0" Designed By Checked By: Project Number: Drawn Br - R AA LVL ' 1/4 x1 7/ M. A LVL Sheet Title,- I CONTRACTOR TO PROVIDE SIILL ANCHORS 5/8'x12 CZJ RATED I I IF - - - - - - - - - - - -ANCHORS 2 O.C., 3 SQ. SLOTTED WASHER - - - heetNUMB & 6' FROM SILL ENDS AND 12' FROM SILL CORNERS n�S1_6•RETRO FITTED RFD TITEN HID CONCRETE SREWSCAS ALTERNATE] ICU ^lO _ __ _ _ _— _ _ _ — _ — — — — — — — — — — — — — — — — — —— — —— — ——— — — — —— — — ,— —— — — — — — — — — — — —— — — — — — _ — — — _ — — — — — — 22' 33' 22' LIVING AREA eb 77' 3989 sq ft! b " �0C* � i 1i , C � k µ f Z � 76'1 Z w¢ Wt. 3 ROUGH OPENING WINDOW TYPE aW MFG'R MODEL z aa. Lnn REMARKS 24. GENERAL NOTES y o W a ' NUMBER o c J a 0 4 Rml 10'6 3'�t�- 10'6 _ < tN J ^ TF----- ---- DUAL BASEMENT CONTRACTOR TO ALIGN FRAMING STUDS FROM FLOOR TO FLOOR �I 2'8-1/4`x1'7-3/4' BASEMENT 1MNDOW WOOD ANDERSEN 2817 -— ---—-—-—----—-—-—-—-—-—-—- 6'3-3/4'x8'2-1/2' FRENCHDOOR W/SDI.TS WOOD ANDERSEN T17 6_FwT3116_ 71716 DUNE p r`4A►N ENTRANCE IN ORDER TO FACILITATE THE FLOOR TO FLOOR -_-______--_-__---__-__ -_-_-_--__- - PAN 4'0-I 2 x7'9 CASEMENT W ARCH TOP WOOD ANDERSEN A C22 DUAL SIDES MAIN ENTRANCE — — — —_—-—-—-—- / ' / CONNECTING METAL STRAPS 2'10-1/8`x5'4-7/8' 1ILT-WASH WOOD ANDERSEN TW2852 DUNE p LR-GAR-HALLWAY-BDRMS -—-—-—-—-—-—-—-—-—-—-—-— —-—-—-—-—-—-—-—-—-—-—-—- c; _-- p . © 2'7"x6'8' - FRNt21YoD HINGED PATIO DOOR WOOD ANDERSEN FWH2768AR OUA LAUNDRY PANE p _—_____________________ ______—__ ® 5'9-3/4'x5'4-1/8' TILT-WASH- COMB(Ki) WOOD ANDERSEN TW2852-2 PANE p WAGE SIDE+LIVING ROOM • �7 6' 1-3/4'x3'07/8' TILT-WASH- C06IB(K') W000 ANDERSEN 7W210210-2 �A� KITCHEN -—-—-—-—-—-—-—-—-—-—-—- —-—-—-—-— I —-—-—-—-—-— I PANE - _ - ® -—-—-— 1 -—-—-—3'1'x6'8' FRNCHWD HINGED PATIO DOOR WOOD ANDERSEN FWH3168AL PANL O DINING AREA ® 9' 2-1/2'x5'6-3/4' 45"DBl-1M DAY M/2-011MITIG UN WOOD ANDERSEN 45-2852-2-20 PANE p DNNG AREA � _�-—-—-— -�I I ® 31"x6'8' . FRNCHWO HINGED PATIO DOOR WOOD ANDERSEN FWH3168AR DUNE p DINING AREA ------------------------ ---- -_--- ------------- ® 4' 0-1/2`x4' 0-1/2' CASEMENT WOOD ANDERSEN C24 PANE MASTERBATH ----------------------_ ---__---- I _______-_-- I --1- --I ®. 7'7-15/16'x5'4-7/8' UNEQUAL LEG ARCH DE3L-HNC WOOD ANDERSEN WU3852 TYPEt-1YPE2 PANE RAGE DORIIER(SEE TAB5 44 1/2" x 46 1/2' UNEQUAL LEG ARCH OBL-HAG WOOD ANDERSE N SKYLIGHT PANE IV6VC ROOta(SFE TAB�A�4-)AJ5 -—-—-—-—-—-—-—-—-—-—-—-— —-—-—-—-—- -—-—-—-—-—-—- I I NOTEt ALL VINDOWS TO HAVE THERMAL BREAK, . o0 A3 ------------------------ ----------._l-Z�-��r=>��a_ 00 pVITH CLEAR OPENABLE AREA OF 5.7 SQ.FT OR MORE _—_____—_____________— —_—_______--__ E3: NZ 21'11 I —_____—_—_ °3 (a) V/ SUPPORT MULLION CL WINDOW SCHEDULE --------------------------- ------------ TO - - . . NOT SCALE ---------------------------------------------------- 1 1 ' -4--------------+ r> iv I ( DECK 11 -—-—-—-—-—-—-—-—-—-—-—-— ---- -- 1 ATTACRIENT F, �• ; 21'11 Artleel 1 II ———————————————————————— ——————————4-—-—-—-—-———--F 1 , 2LnWr I I 1 ,1 24 00W asss 1 11 —-- — w d0deties 1 ,1 ------------------------ --------- 1Q 1 ,1 1 ,1 1 1 (� . f-►FllrStro� 1 ,I '� tt n)sags dlod+ld i1 ; 1 I o ,� o 1%(6mMes4'tlea�ldb ------------------------ -----------r--------------r 561"Im ow rob lr 11r,r •• ' _ 11 In tnenj Jkf P K j I W -_-_ _-_-_-_-__ -_=_-___=___= ldldMpel t7i710etMrtnwMMM ; �� ------------------------ --------- -- ' rswrrwurtirlq l� � ,1 btlal b'y` 1/1 tedfitq �woo,r k M•s i swe. 1 l i I I r 1 M Ids It 6'el pr plat a►illy a#bll wra l i I ( vt— *-Md to/ek,tn" w Mamie w lie k w , ;1 O C 1 1 II 1 ,1 4'10 171 30'11 in 0 U1 , —f- 8'6� 3' '7—�}�2' --77'10 7'10 6' 3' 3'1 Z � 1 H 3 U _l JOIST AND BEAM LIST E '; U o W Q UP Plot ID Length Product Plies 6 ;; A cu 6' Q M Q Z fy A24 24' 14' TJI560 JOISTT y 3 172—V" P1 6' 3 1/2' x 9 1/2'ZOE Para(lan PSL 1 `---------�-"-- P2 18' 3 v2' x 11 7/8" 2.0E Parallam PSL 1 2 .OE Par PSL <Pry P3 12' 3 1/2' x 11 7/8" 2.0E Paraltan PSL 1 _ __ __ _____—___ ___ ___________ Normal O.C. Spacing - 16' --- --------- --------- ------------ ---- U0 z � X 4'10 co OU W ACCESSORIES LIST Q z Rnl 16' 1 114' x 14' 1.3E TlnberStrand LSL 1 Shl 4' x 8' 23/32' Strucrwcood Edge Gold (24' Span Rating) 1 ___ V-- —___—_______ ___ H--1 W W Rm, Rim Board ° ° _ Z --- ------------- ---M ------------ -s o --- ------------ ----------------------- z U --- ------------ ----------------------- _1 r (U ____________ _ _ 3 c-s.-- -------- NAILING REQUIREMENTS �A----------------� '1 x 2 -------------------------------------------- VISTA TJI joist at bearings : Two 8dl (2'/ " ) box na'iiis (1 each side), 1 %" J ______-_____-_ _________________ �,�___ ______ RESIDENTIAL DESIGN minimum from end. Blockingpanels, rim joist or rim board to bearing plate: 5' d - - ---- __ P.O.B. - 634 .A � REMSENBURG TJI Blocking panels or rim joist:1Od (3") box niails at 6" o.c. co __ ___--- ----------------------------------- TJI Joist rim board: Toenail with 10d (3") box snails at 6" o.c. or L� NEW YORK 11940 � .. o (U 0 i 16d (3'/z") box nails at 12" o.c. ------- ------"-- ----- "-------"- '-"-" --d-� Shear transfer. Connections elquevalentto decking nail schedule. ________ _________ ________ _____ _________ __________ ____ ___________________________ ISSUE FOR CONSTRUCTION DATE 1 Rim board, rim joist or closure to TJI joist: I I I I I I I , , I , I , , Revisions { ?%" width or less: Two 10d (3") box nails, one each top and bottom flange. I I I I I I I I I N I I I 1 1 1 1 1 1 t_ _______ _______ _ ________ _________ ____________ _ __-_______________-________ No. Date Description 4 � � I I � 2 "trhu 2W width: Two 16d (3'/2") box nails,one each at top and bottom flange. I 1 I I I I I I I '1 I I I � ------- ----------------------------------- ------ -------- --------------------_______ 3%"width: Toenail joist to rim joist with one 1 Od (3") box nail each side of joist top flange. o I 1g's g. 1 1 I I �' I I 12, I I I I I l 1 I I I I I I 1 N 2x4 minimum squash blocks: Two 10d {3") box nails,one each at top and bottom flange. -------- -------------------- ----------- -------- ------------------______ o L 1 -- _ I I I I I I 1 1 I ------- ------------------ - --------- - -- --4 1 — 1 1 1 , 1 1 1 1 , 1 n- I I I I I I I I I — - — - — -- — �� I 1 1 rj 1 1 1 1 , 1 — - -------- ---- --- ----- -------- w I I I I I I I ------- ----2x��-�:.� --- - - -- - -------- -- --- ------------- ----------------------- o T 1 I 1 1 1 1 1 1 I ° Rj 1 I I � L, =i @16' 0_C.-- — ------ -------- — -- — ----- — -- — ------- -------- ---------------------- � -- - I -------- ------------------- -- - ---------- I ------ -------- ------------ ------------- s 1 1 1 1 1 1 1 I 1 ------------------- ----------------_— I I I I I I ------- ------------------- --------- ------ -------- ------------ ------------- N r— t -------""_--------- --- --------- •—'� 1 1 1 1 1 1 1 1 I 1 ------- ----------------------------------- ' — ------ -------------------- � I I I I I I I I r '� Designed yi Checked By, X L------------- ---@G'e--E}�;------------ 1 I I I I I I I ---- — ------- ------------------------- -------- ------------ ----------------------- rojec umber) Drawn By1 (U I 1 I I I I I I I I M —4 I 1 I I I I I I I (- Sheeti e1 1 1 1 1 1 1 1 P R [1 , P [I S E D . _ N ——-—-—-—-—-—-—-—-— —-—-—-—-—-—-—-—-—— (� -- -- —-—-—-—-—AND ---- --------------------------- C I F , , I CU -------------•---- ------•----------- - -- -- I 'hest Numb _ ' F--T-- ---F--T---I---1-- -D---I---T-- ---r--T--T 1 �3 2 ------- ---- — --------------------------- ' CU [i- E FRAMIN ( I N I 1 e 1 1 1 1 1 1 1 1 1 1 1 • � I 1 I 1 I 1 I I I I I I I I I I I N ED A cH� 0 1 t 1 1 1 1 1 1 1 1 I 1 1 1 --- ------ — --------------------------- G.1 r�(1 - I I I I I I I 1 I I ( I 1 I 1 M�Tr r O 29 4' 84 I I l t l l l l l t 1 1 t l o --- ----- - - ---------------------------- c� F _ _ V V V ----- a - 4' m I'-.". . 6'9-- 8'6--- 6'n `1 6' S'2 1'11 2' 2' 2'1 5' 6'n J 6'9— 1'9 6' — 6'9----� u�qT 32$ AID SCALE: 1/ O , . . . £ OF NEB 22 lllll 94 119 8 ` 136 t ( 77' z f: 76'1^ - -- x p Z �.• GENERAL NOTES: Z W- W I 10(6 1Q'6 , I 3 ROUGH OPENING WINDOW TYhE 4 IMFG'R MODEL z 0- N REMARKS z Cr W NUMBER w m N r. a k Wei G _ N n I I I I 1 28-1 4"x1'7-3 4' BASEMENT WINDOW Q / / 'DOW W000 ANIDERSEN 28t7 pNE BASEMENT t ® 6'3-3/4'x8'2-1/2' FRENCHDOOR WpaTS WOOD ANIDERSEN Tt 16-FWT_ _ IA311 - 68 PP�AINE O MAIN ENTRANCE — — AFC22 DUAL - - -—J 1 1 I i i �i i i j i I , L---- - © 4'0-1/2'x7 9 ANIDERSEN PANE SIDES NAM ENTRANCE CASEMENT W/ARCH TOP WOOD ANIDE O 2'10-1/8'x5'4-7/8' TILT-WASH WOOD ANIDERSEN TW2852 PANE O LR-GAR-HALLWAY-BDRMS — -—-—-—DUAL v _-- _ v%` I I WOOD NMERSEN rM2768AR N UNRY —_ —_—-_--_2'7"x68' FRNCHWD HINGED PATIO DOOR !N I tU 5'9-3/4"x5'4-7/8 TILT-WASH- COMO') WOOD ANIDERSEN TW2852-2 O AGE SIDE+UYNG ROOM pN — -—-—-—-—-—---j ILT-WASH- CO(•) WOOD ANIDERSEN T2102102 KITCHEN 1-3/4'x3' 07/8' E II------------- --N I ! I 3'1'x6'8' FRNCHWD HINGED PATIO DOOR WOOD ANIDERSEN FWA3168A1 ppNE O DINING AREA _ ____—_—___— _ ® OD 9' 2-1/2'x5'6-3/4' 45'DR-1IM BAY N/2-01 f JM.G IN W000 ANMERSEN 45-2852-2-20 PANE O DINING AREA I—-—-—-—-—-—-— - 3'1'x6'8' fRNCHWD HINGED PATIO DOOR WOOD ANIDERSEN fYVH3168AR pAL NE O DINING AREA — -—-—-—-—-—-—-—-— N - © 4' 0-1/2'x4' 0-1/2' CASEMENT WOOD ANIDERSEN C24 DUAL MASTET28ATH __ —-—-—-—-—-—-_ -—- I —-—-—-—-—- I -— PANE ! -- —�-- —� 7'7-15/16"x5'4-7/8'. UNEQUAL LEG ARCH DBL-HNG WOOD ANIDERSEN WU3852 TYPEI-TYPE2 pNE ARAC£L10RI,IER(SEE TAB A3-A5 I ® —-—-—-—-— —-—-—-—-—- -44 1/2' x 46 1/2" UNEQUAL LEG ARCH DE3l-HNG WOOD AMDERSEN SKYLIGHT I PAN ROON(SEE 1A8 A4+5LO — I I -- ----------------------- ----------l...� NOTE, ALL WINDOWS TO HAVE THERMAL BREAK. I I I I I OWITH CLEAR OPENABLE AREA OF 57 SQ.FT OR MORE __ _____________—_—___—_—__ —_—_—_—_—_ — 00 N/ SUPPORT MULLION 21'll ' ' ' ' o W 1 N D 0 W SCHEDULE -- ------------------------ -------- _ 1- rJ - -! - -! - -! - - NOT TO SCALE / ► I ! I I I I I , i I•- ; I /7 ---------------------------------------------------- TIMBER FRAMING NOTES ' I I I I - ------------------------ - FOR STRUCTURAL GLU-LAM TIMBER. ALL STRUCTURAL GLU-LAM LUMBER -- -- - � � SHALL 'BE INSPECTED DURING LAMINATION BY AN APPROVED INSPECTION _ AGENCY. EACH STRUCTURAL ,GLU-LAM MEMBEER SHALL BE STAMPED WITH 21'11 _2x12 R.R. AN IDENTIFYING NUMBER. A CERTIFICATE OF INSPECTION CERTIFYING '' ul THAT THE MEMBERS HAVE BEEN INSPECTED AND MEET THE REQUIREMENTS I I '' -- ------------------------ ---- - ' - ABOVE SHALL BE FURNISHED 'TO THE ARCHITECT BY THE SUPPLIER. I I I OI I NO` SUBSTITUTION CAN BE MADE • WITHOUT ARCHITECT'S PERMISSION. ' I I LEDGERS AND OTHER STRUCTURAL TIMBER: D►.F. GRADE #2, U.O.N.; ° qj� I �� LEDGERS OR ANY MEMBER IN CONTACT WITH CONCRETE OR MASONRY CD SHALL BE PRESERVATIVE TREATED. -- ----------_-----_—______ —_—___—_— I I I I 1 , RAFTERS AND JOISTS (2X'S): D.F. GRADE #22, F'b = 1450 PSI' (REP), __ ________________________ ________ 2 12 R.R. F'v = 95 PSI, E=1. 7AO PSI, STUDS: D.F. GRADE #1 °,° I @ 16' D.C. (1J ' (LJ '' N -- — - — — -- - ---------- I -- BEAMS (3X's, 4X's AND 6X's): D.F. GRADE #11, U.O.N. ALL BEAMS TO BE SUPPORTED WITH FULL WIDTH BEARING. _ __________________ ' ROOF SHEATHING: 5/8" APA RATED, EXPOSURE 1, 32/16. I I I ' " 24 0. ALL I E ? I-j- WALL SHEATHING: 1/2 APA RATED, STRUCTURAL t, / __ I WALL PLYWOOD PANEL EDGES TO BE BACKED, BY 2x ; ' - '-----"-- ! p ! I�------------- 4 10 17 1 �� 30 11 ! , I CU k I ( I I� I � U BLOCKING FROM ROOF LINE TO FINISHED FLOOR, t — T 8' 3' '7�2' 7"10 7'10 6' 3' 3' -- -- INTERIOR FLOOR SHEATHING: 3/4" MINIMUM, T & G. I ---- ; I I ( N �JJ I I ►-�; (-" APA RATED, EXPOSURE 1, 40/20.ADHERED W,/PL& NAILED — ------ — 1 I ! 1 I 1 1 I 3 U ALL PLYWOOD SHALL CONFORM TO U.S. DEPT. OF COMMERCE El -- ----� I ! i i I --- -- o WED PRODUCT STANDARD PS-1, ,1 NJ __ __ _ I I I I ! E INSTALLATION: ALL WALL PLYWOOD PANEL EDGES SHALL BE � _____ _-__- ------------- - - --I- ''I ! ! N I / 1 t 1 g Q F BACKED WITH 2-INCH NOMINAL FRAMING (BLOCKED). • - I 1 -1- -J Q _ z LAY HORIZONTAL PLYWOOD SHEETS ON FLOORS AND — ------------- --------------------- I ! I ! i 1 I I ! I I ! 1 i ! I j ! 1 ! II I Q U � ROOFS WITH LONG DIMENSIONS PERPENDICULAR TO M - i I I , I 1 , I i i I II -- -- --- - - --------- -------------- -- F-- --� JOISTS AS DETAILED. PLYWOt)D FOR WALLS (MAY BE - ---------------------------------- _ I INSTALLED HORIZONTALLY OR VERTICALLY. ALL 4'10 EGENCY EXCLAIM 50 GAS FIREPLACE -- -------- --------- ------------ --- -- iNn W VERTICAL JOINTS SHALL OCCUR OVER STUDS. - ------ --------------------------- I i 1 i I z ALL PLYWOOD, LIGHT FRAMING, DIMENSIONAL (LUMBER AND GLU-LAMS - ____ -_-_--_ I ! I I I I ! ! I I ! ! 1 ! ! I ! I (� H SHALL BE STAMPED WITH THE APPROPRIATE (IDENTIFYING MARK ON -'-'--- I j I ! I I ! I I I -- ---- --- --- ------------ ---- -- LJ W AN APPROVED INSPECTION AGENCY AND/OR (LUMBER GRADING AGENCY. - - - - ' 1 -----------� I I I I ! 1 (1J I I ! I I I ------ o -a --- ------------- -- ------------ -- I SOLID BRIDGING WILL BE PROVIDED FOR ALL �JOISTS,FLOOR BEAMS AND RAFTERS AS PER NYS CODE __ I ! I ! I tU 1 I I I ° 0 3 = SOLID BLOCKING WILL BE PROVIDED FOR ALL PARTITIONS,AS PER NYS CODE --------'-- I 1 I I I I ---'---'- o o --- -------------'----- ------------ ---- -- W I— I- 8'-0 O.C. MIN.' PROVIDE 2" OF AIR CIRCULATIION IN ROOFS I- - - ------------ ----- ------ --- ' --------------- I -- !---�-- I--rill - z 0DOUBLE FRAMING,[GIRDER],WILt_ BE PROVIDED UNDER PART'11IONS RUNNING PARALLEL TO FLOOR JOIST o II I DOUBLE FRAMING WILL BE PROVIDED AT ALL OPENINGS,[STAIRS, SKYLIGHTS,ETC] `l' `D "�- -- --- -�---- ----- -_---- --- _-___-__-_-__. I ! 1 I ! ____---__ -__ ___ _-__________ _ Q € DOUBLE FRAMING WILL BE PROVIDED AT PERPENDICULAR INTERSECTION OF ALL STUD PARTITIONS I I I I " O F- - - ------- - ---- --- I' I I I' II 'I I 'I 4 3 STEEL HANGERS, HURRICANE CLIPS,SADDLES �& SEATS: SIMPSON OR APPROVED EQUAL, _ ____ ________________-_____ SECURED PER MANUFACTURER'S RECOMMENDATIONS AND AS NOTED --------------- -'�-- I II I ! ( I jl 1 !IVIT-1 "'1- -------------------ON THE DRAWINGS. %D - ------------ -- ---- --- ----- �, kY11 _�X1ZR.R �. ,1 - - — ----- 2x12-R-R-- — — - I I -- — .1 --------------- --------------------------------------------- --- ALL @16' � HEADERS 6'-0 AND GREATER WILL BE SUPPORTED WITH DOUBLE STUDS.AND 9'-0 AND GREATER @16' O.C. I . I I I ,I I I _ _ RESIDENTIAL DESIGN WITH TRIPLE STUDS,[U.O.L.] — ------------- ----- --------------- ALL HEADERS SHALL BE A MINIMUM OF (2] 2X8 [U,O.L], AND WILL COMPLY WITH NYS CODE. --_---_—__-_-___--_--___--__--___—_ — NAILING SCHEDULE WILL BE AS PER THE NYS CODE 5' ______________-_�-�__ _ o _ I _ __ __�_.� _ ____________ ________________ P.O.B. 634 ' 4 �-X II - —" REMSENBURG ----------------------------------- PROVIDE WELDED METAL PAN FLASHING AT AILL DOOR OPENINGS. rt ------- ----- -- -- N -- -- -- -- — — ---- ---------- ------- ------- ------------------------ -- NEW YORK 11940 DOOR AND WINDOW OPENINGS WILL BE V1SOUEEN WRAPPED. I I , -__________—__-_-_________-_ x ----- ---------- - - I -- , I -- - ,----- ,-- , --t-- --r— -- ---------- ----- wili I `---- ------- ----- ---------1 -,-- Revisions th -- ---------------- - -------- ---------- I I ( I 1 No. Date Description �--- j • - --- ---------- ----- I ------------------------- t i - ----- --CONTRACTOR TO PROVIDE — - -- - - —• I I , cv o is II -- --- -------7-------- 17'/16' PLYWOOD FOR ALL NUMBERED o _ _-- _ -- ! ' � ` ____-- _ -- I , I � -- -- _—' n' ---------__ _CuU° - --- ---------- ----- 1 ! -- - - ----- N I I -------------- WINDOW - & DOOR ASSEMBLIES IN W/ IBC CODES ----------------- COMPLIANCE — � I _ i �; I i I IN -- - - -R. --- ------- - -------------- I- ' -- 1 , 2x12 R.R. -- ---------- i ! I I i I t X I ! j I -------- -- @16' 0. �' --- -----�x-1��T��,r- ------------- ------ - -- j I j I 1 i I 1� I I I 1 i I j` -------- -- --------- ------------- -- @16 O.C. 1 ' , , _ _ , 1 i ( ------- - Desi ned Checked B t -- -- --@�6---8�G. -------- ---------------- - --- ------- I I I I 1 j -- - -- ------------ --------2x12 R.R. - -- s Y' y I I I I _ Project uMberl I - -- -----' i I I I -- - ------------ I ----- @16'- D.C.❑ C -- _ J Drawn eye t. • ' -- -------------------i i i-------------- - - j i ----- ---- --- 1 - � - ----------------/1 ' ,`---------------- , , I , , -- -- , , I , --------- ---- - 1 ----------------- - Sheet i Lei I I I I • 1 1 ! I I I I ! 1 1 ! 1 I I , I t 1 I , � I , I 1 I I P R [I S E D -- --------------/! ! ! ! !`;--------- - - --- - --- I ! I ! ------------- - heet Numb '" I I I I I I I I I I I I I I I I - I-- -- I- -I -- --I I 1 I I I I I I I I I I I I I cu ---- --- - N I `�------- FRAMING -- --=----- I i I i e i I ► ' -- "' -- c--- ---- --- -- -- I ---- --,� 1 1I --------- -- ~ 1 , ------ I - fILLi i 1• 1 i I , D AR hi S -6 (U1, 1 N I I I I I �----- -- I ! I I Cll Dtn 6' 6' 5'2 1'11 2' 2' 2'1 5' 6' IL I '9-�—I 1'9�}�T6'4- I -I-6' s 1as2$ SCALE: II4" = I'-O" Jlq" OF NEB yO 22 11 11 9p,4 11 9 8 13 6 ( 77' J GENERAL NOTES; a a . s• ,�K w�JaST BIOCK(NG PANEL, DIEROR ATTACIPOT AT END BEARCVG ra %ldbw hot•Laofw: • M do pm ap lRlrir rt wd�t • r �hDd�t wM y bae4i!• owov` J / +i6 IN wl w ray u wft r� p ni WINDOW WELLCTYPICAL ;a&A fFiwnlSK flwhtrulrn bwaon, 1w ibw fde I ftw 1184trvt(wpks¢p /�V'•ft � CRUSHED STON _ pm in % v JUST 10 BEAD CONNECTION . r A L iy U m f x L j ly ASEMENT WINDOW ` 'vh h ba of bean. ' � / •` } Altadrned le�gKd h ales y PERFORATED CORRUGATED PIP TO CATCH BASINkelp sw • k t�'!e e Ste dfkic6�ie o*w bl B F-� UNDISTURBED SOIL- a ._ U �- o L TOP RIDGE DV, KITCHEN+ TIMBERLINE C30> Q Q ASPHALT SHINGLE U = r AND DINNING AREA@ 28'8' F.F. CHARCOAL GRAY Z (2)15# FELT TYP. 3 U _I TIMBERLINE (30) 1/2' CDX SUB-ROOF �J Q ASPHALT SHINGLE 2x12 RAFTERS @ 16' D.C. Q �/ CHARCOAL GRAY UNLESS OTHERWISE NOTED Q � (2)154 FELT TYP. 12 Q Z 1/2" C X SUB-ROOF 2)2x12 RIDGE ._.1 U w 2x12 RAFTE RS @ 16' D.C. 2)2x12 RIDGE q UNLESS OTHERWISE NOTEDLi r� ZEK FASCIA W Q AZEK BEADED SOFFITS 3 Q = S 4. PROVIDE CONT,VENT z Q a_ F W/INSECT SCREEN TYP. _J R-38 INSU ATIDN (TYP QED ALL TRAY CEILING @ 12 0 F.F. 2X10 COLLAR BEAM 16 O. - �2x12 RA 3 �2 X, 6 STUDS B@16'DD�VER FTERS16, DCI ,. WITH R-19 INSULATION M` TOP WALIL @+ 9'0'F.F, A= N 2x10 CEILIN JOIST 1 VISTA r R-38 INSULATION (TYP) -I�2'x9 I12• 0E PARALAM PS ��ZEK FASCIA RESIDENTIAL DESIGN STUCCO MST4 BATH 3-1/2 1-7/8 PARALAM SL � i \�AZEK BEADED SOFFITS DRYVIT SYSTEM I - P.O.B. - 634 (2) 15# FELTI N o ! BATH PROVIDE CONT.VENT REMSENBURG 1/2"CDX SHEATIN C I DINING , W/INSECT SCREEN TYP, 2x6 STUD WAL E T AREA PANTRY STUCCO NEW YORK 11940 I � R-19 BATT INSUL,TYP � L - DRY DRYVIT SYSTEM WALK-IN WALK-IN HALL 1/2' CDX SHEATHING 1/2 GWB W/3CTS SPACKLEI CLOSET CLOSET �— ISSUE FOR CONSTRUCTION DATE 3 4 LYW ., CSU L �� F {—� 3/4' PLYWO (SUB- 0 2X6 STUDS WALL Revlstons WINDOW WELL<T AL D UBL PL 1 - 2x (--t DOUBLE P TE 2 R-19 INS.BATT.CTYP) No. Date Description FIRST FLOOR -'FLOOR @ 0'0' T RMI E-SH LD T MITE- L 1/2' GWB W/ 3 CTS ti CRUS D STONE SPACKLE(TYP) i @ '-0' O.C. & 12' FROM L -21 INSUL,(TYP.) — EA H END (2 PER PLATE —MIN.) 4" DIAM. STEEL LALLY COLUMNS. I14 REBARS CONTINUOUS BOTTOM CRAWL SPACE WALL @ -4'4' F.F. IIIII Mill f BOTTOM FOOTING @ -510' F.F. BA EMENT WINDOW PERFORATED ORRUGATED PIP 1O' TO CATCH BASIN BASEMENT f @8 72' D, #4 REBAR (2 #4 R BARS CONTINUOS FOOT N CONTINUOS 4' CONCRETE SLAB OV 4' A.B.C. 4' CONCRETE SLAB OV 4' A.B.C. DOTING BOTTOM FOUNDATION WALL @ -10'4" F,F. •.;:: FOOTINGS @ -11'0' F.F. Designed+ •i g y Checked Byt BOTTOM ; '.�,I.�► • ,i. *. i.'7 -:* Project Nurnberg Drawn By, � ) BB 2 O.0 VERT CARS A�T RNA T E @@ ��77 a L E� ALTERNATE BEND IN FOOTING IN FOOTING hee it e NDISTURBED S01IL UNDISTURBED SOIL UNDISTURBED S❑IL Sheet Nurnbe SECTION A - A AC -ROSS BUILDING �o Rcy T Al A,1 21 i S Or i a GENERAL NOTES S P E C I F I C AT I O N S: fro SQUASH BLOCKS AT INTERIOR MfIG ft9 SQUASH BLOCKS AT CONCENTRATED LOADS PLUMBING , ,W bW VWW*m Of.x"bw".a ow o MI&W Jasr lwN iRm dw) y. FURNISH LABOR, MATERIALS TO COMPLETE WORK SPECIFIED OR INDICATED ON PLANS, INCLUDING BUT NOT LIMITED TO THE FOLLOWING: to" Val b"'"`..�.'rr�" � DRAINAGE, SEWER WASTE, VENT SYSTEMS, COILD WATER SYSTEM, Y` HOT WATER SYSTEM, PLUMBING FIXTURES. AND WATER SERVICE. MATERIALS, METHODS AND DETAILS OF PLUMBING WORK SHALL CONFORM TO �y1I' i e.bliAllm twbHl+, M.fm,at10 "UNIFORM PLUMBING CODE" AND APPLICABLE STATE AND LOCAL CODES a...,... (LATEST EDITION), �Ill b6+SJir/pose 16+s/r 1r� PIPE PIPING INSTALLATION nr� aI+S/I'�p�e ae+s�ro.ed '. A. METAL PIPE SHALL BE STRAIGHT, FREE FROM DENTS, SCARS, BURNS, +s/ee> s1D4 ' ky AND DISTORTIONS, END REAMED OUT SMOOTH. + + S. PROVIDE PROPER ALLOWANCES FOR EXPANSION AND CONTRACTION. A ������■��� C�FAN pI INS N 1riSTA LED Epp {� F q " So,asf.ebd, �. ,b m 4 te�.e l��v ithm t s� aw met d r b L Pk' AND GR 1. Sbit. WASTE r1RT�It -GE, UNIFORM 1/4 PER (2 ' x FOOT EXCEPT WHERE SHOWN OTHERWISE. 2. HOT AND COLD WATER; eR.hy.a. Roc,0�bbr%gOeWInW0A2msdINNh LEVEL OR SLIGHTLY PITCHED TOWARD DRAIN POINTS. F►i,,,,•tK•a�.. d •aew, ftFEW �ggmwwte 'OSEdAadKgkHidbldk ebb onyC. SIR dob d psh trmi in b 6es4g WN t PIPE AND FITTINGS: ,�o.- .aa+�.en.••a�+eeen�.a.v„�e•oHo. 'a"ad'"'e•+r'4°ia°d° r A. SCHEDULE 40, PVC PIPE SHALL BE ACCEPTABLE IN LIEU OF CAST IRON ***bW k*„N ON Ow W WWI 044% ,ffm TIMBERLINE (3 0 ) FOR DRAIN, WASTE AND VENT PIPING WHIERE APPROVED BY, THE LOCAL 10,pw..,,. GOVERNING B. IN OCATIO SODES WHERE IPVC SINNOT APPROVED FOR USE, PIPING " ASPHALT SHINGLE SHALL BE SERVICE WEIGHT CAST IRON FOR SIZED LARGER THAN 1-1/2 , OBST SPACNG BELOW PLUMBING WAIL OR GALVANIZED SCHEDULE 40 STEEL PIPE WITH MALLEABLE IRON P1 JOIST TO BEAM CONNECTION CHARCOAL GRAY �x 12 RAFTERS 16" O.C. SCREWED VENT FITTINGS FOR SIZES 1-112" AND SMALLER. �.br C. FITTING TO BE SUITABLE FOR TYPE OF PIPE USED. D. ALL DOMESTIC HOT, COLD WATER LINES ,ABOVE THE BUILDING SLAB TO c A • (2 ) 1 S# FELT T Y P, BE TYPE L HARD COPPER IS INSTALLED, JOINTS BETWEEN PIPE w rwe tiHr AND FITTINGS SHALL BE BRAZED. NO JOINTS WILL BE PERMITTED IN cis ' • 1 1 /2 " C D X SUB —ROOF S H E A T I N SOFT COPPER UNDER THE SLAB. E. ALL CHANGES IN PIPE SIZES IN SOIL PIPE SHALL BE MADE WITH ■■ r r �°�°i REDUCED FITTINGS. WYE FITTINGS WITH 1/8" OR 1/16" BEND OR Ip na i kr7m COMBINATION WYE AND 1/8" BEND FITTINGS SHALL BE USED WHERE CHANGES IN DIRECTION OCCUR, SANITARY LONG SWEEP BENDS OR TEES AFTER TAILS MAY BE USED FOR CONNECTIONS TO BRANCH LINES, TO FIXTURES, AND SUB—F A S C I TO ALL VERTICAL RUNS OF PIPE. INSTALL IN ACCORDANCE WITH UPC , �'—L�X8 CJ.@16• O.C. APPENDIX "ID". AZEK — TRIMBOAR F. SLOPE ALL SEWER PIPING 3" AND SMALLER AT 2% PER FOOT AND 4" AND LARGER AT 1% PER FOOT. kFvwe b ROOF DRAIN PIPING WHERE SHOWN ON DRAWINGS, SHALL BE SAME AS be%W etSai A Z E K — BEADED S O F F I T SPECIFIED FOR WASTE PIPING. VALVES Eby*. B A. VALVES SHALL HAVE TEST RATING OF MOT LESS THAT 125 PSI. F R I E S E — B A R B. VALVE MATERIAL: BRONZE MATERIAL FOR SIZE 2" AND SMALLER, IRON Egyw k BODY BRONZE MOUNTED FOR 2-1/2" AND LARGER. gbrbHAd 1/2"/ G.W.B. W /3 F STUCCO — CTS ,SPACKLE TYP, CLEANOUTS: I A. FULL SIZE CLEANOUTS SHALL BE INSTALLLED AT THE BASE OF EACH D R Y V I T SYSTEM M WASTE OR SOIL STACK, AND AT THE END OF EACH HORIZONTAL RUN OF 2 x 6 WALL 16 a ❑,C , t-'--i PIPE. THE DISTANCE BETWEEN CLEANOUTS IN HORIZONTAL RUNS OF 1 S # FELT —PAPER PIPING SHALL NOT EXCEED 50*-0". W/ R —19 B A T T S F B OR SHALL INSTALLED AREAS WVHEREVER POS LOCATIONS SIBLE) MERE SILY mom svEaF►cATlorvs 112 C D X — S H E A T I N __ STACKS OR OTHER PIPING ARE CONCEALED, CLEANOUTS SHALL BE H.�., H»e•� oo•• H LATE U �— AaWjftMq AdWdIFMWJAtYI AeW � F INSTALLED FLUSH WITH FLOOR AND PROWIDED WITH FLANGED CLEANOUT I COVER. PROVIDE ACCESS PANELS AS (REQUIRED. - �u �N .,.. .OHM "•. Hs,a ��. en■a GC A L L E W 5/ 4 ii I ROOF FLASHING: FOR FINISHED FLOOR �- --� A. VENTS THROUGH ROOF' TERMINATE 12" ABOVE THE ROOF OR FIREWALL. x /4 " P L Y W O O D( S U B —F L O O R ) a x B, FLASH WITH LONG BOOT LEAD FLASHING AROUND PIPE. �— (� G C. THE BASE OF THE FLASHING SHALL BE IMINIMUM 12" X 12" ON THE ROOF. �h' �� DOUBLE PLATE 2 x 6 A C Q t SANITARY SYSTEM: � �« RIM BOAR — Z >-- A. CONTRACTOR TO VERIFY ELEVATIONS OF SEWER MAINS BEFORE STARTING t°"•^"•`"' 1 / X 1 S" ANCHOR BOLT @ TERMITE SHIELD 3 ( 1 J WORK. LAY PIPING TRUE TO LINE AND !GRADE UNIFORMLY UNLESS v I I OTHERWISE INDICATEDOUTSIDE OR DIRECTED, MAINTAIN 36" MINIMUM COVER 4 �0 �� O.C . & 12" FROM EACH E N 11— 7 /8 �� ABOVE PIPING OU S •.....�H H,.`•.n,s.w r.,n A J S 2 0 M S R aria lM M1•p,Ot• p•s"p,Y w h poet. WATER SUPPLY SYSTEMS: C 2 PER PLATE —M I N) Q A. BUILDING PIPING: PROVIDE A COMPLETE: PIPING SYSTEM AS SHOWN ON 6H'MeM Mgnt t).t PLANS INCLUDING SHUT—OFF AND DRAINI VALVE ON SERVICE TO ALL , "°"w a:ia„0+ ee�r Q FIXTURES AND EQUIPMENT OUTLETS REQIUIRING A COLD AND/OR HOT J th.& WATER SUPPLY. ALL BRANCH MAINS ANVD CONNECTIONS TO RISERS SHALL ► 'ar ~ W BE VALVED AND DRIP COCKS PROVIDED SO THAT THE ENTIRE SYSTEM Oi16o''°'' ar Hwr f•— MAY BE DRAINED. FIXTURE STOPS SHALLL BE INSTALLED ON ALL FIXTURE '"r #4 R BARS BASEMENT z � W06Co CONNECTIONS. ar C❑N TI ❑US U (� W ►—, E— z TESTS FOR PLUMBING AND DRAINAGE SY$TEW-S_• A. ALL HOT AND COLD WATER LINES SHALL. BE CAPPED OR PLUGGED AND Ld TESTED WITH 125 LBS. HYDROSTATIC TE',ST AND PROVEN TIGHT BEFORE H ANY PIPING IS COVERI_D OR CONCEALED IN ANY PART OF THE BUILDING. PLACE B. ALL WASTE AND VENT' PIPING SHALL BE TESTED WITH WATER OR AIR E R �, (� I N G ® R GAS FIRE FREEZE-PROOF AS REQUIRED BY THE UNIFORM PLUMBING CODE. O C. GAS PIPING, IF ANY, SHALL BE TESTED .AS REQUIRED BY LOCAL OR LIJ STATE GAS CODE. i D. CONTRACTORLSHALL MAKEE OF THE SYSTEM AS ALL ADJUSTMENTS ASA MOLE, THIS R REQUIRED AND PLACE UNDISTURBED S❑ I Q s` THE ENTIRE PLUMBING SYSTEM IN SATISFACTORY OPERATING CONDITION. E I N F ❑R E D CONCRETE WALL FIXTURES: I A FURNISH AND INSTALL, PLUMBING FIXTURES, TYPE "A" QUALITY SPECIFIED 8 R E B A R 3 IN THE FIXTURE LIST. 2T;C. ,# 4 B, THE CONTRACTOR IS (RESPONSIBLE FOR PROTECTION OF FIXTURES UNTIL 1 . 5/4 X 4 CEDAR CAP FINAL ACCEPTANCE OF THE BUILDING BlY OWNER. ANY DAMAGED FIXTURE SHALL BE IMMEDIATELY REPLACED BY THIS CONTRACTOR REGARDLESS OF WHO CAUSED THE DAMAGE, CONTINUOUS 2. LINE OF PORCH CEILING BEYOND. CONTINUOS F O❑TIN �2) #4 R BA V I S T A C. CON C�TRAC/BOI ER FEDrJISH HOT WATER HIEATER [75 GALLON] 3, 2 X 4 TOP NAILER. GRAVE CONCRETE SLAB ❑V 4 " A,B,C , RESIDENTIAL D E S I N t 4, 2 X 2 BALUSTERS. PERFORATED PI E 0 @ FOOTI REMSENBURG 5. 2 X 2 TOP SUPPORT 8 N❑TDC❑NTRACTOR TO LOCATE ROOF NEW YORK 11940 TINGT REAR ❑F HOUSE. BETWEEN BALUSTERS. N D I S T UR B E D SOIL VEN 6. 4 X 4 CENTER SUPPORT. o, 7• 2 X 4 BOTTOM NAILER, ISSUE FOR CONSTRUCTION DATE C4) REBARS @ 72" D.C. Revisions . 8. HB&G 12" PERMACAST SQ. COLRDTSIC�I FDWNATE No. Date Description I : g, BASEMENT AND FIRST FLOOR SECTION t 12 i 316" 12 11 3" RU �017 4 3" THRU ROOF No -te : W is the -thickness of the wall 1 3" THRU �OOF 2 I 1 i 4 N\'-n6 (5 1 _ Designed y Checked By, / JW(pER _ .I-L 1BUC`SI_ AT TMn9TER I3 H 1 1 Project Number• Drawn By 1. I'T(CHE�1 21 . LAUNDR � i• 2•� BATH 1 r 1 7 1 — _ — _ _ .— _ ._ __ ._ .— _ _ 19nK)SItHK D.w. w.0 lAV — tAV UN w.0 _ tAV — — — — — CtA IR Sheet Title, C.O. CA C.O. heet Nur1b 4 ♦ NEW SAWARY SYSTEM I RASE►EW FRONT P01�\' C '� I ELEVAT ON aL ,u m 13 1, N G R I S E R D I A 6 R A m MtiiFcr oP � ,4- � 032$ F•� , NO SCALE OF NE`iI y0 �'• FL ❑ ❑ RING SCHEDULE • ENERAL NOTES. � SPEONK CROYW ALLOW.[12.00/LF] 1 . T&G W❑OD RED DAK FLOORING •C#1SELECT) FLOORS T❑ RECEIVE CARPETING E T A ED Y NS LL �4 / D I A OW 0 A M P OL Y URE THANE) LL M C N J 3 CO A T MI I . 4 V T NE T CI E S ❑ F RS 0 RE E 'N F L❑❑ T I . G T RE CIE V E IL B FL❑ ORS ❑ PPotvI 4 I F SPEONK PRE COLON 86 W�1 /S ) t A LO 5 A T R [ L NTR C D Y CD /� W /SFJ I NSTALLED B � ] �° T ACTO RCALL❑ 10 I NS TALLE D B Y C❑ N R :r- a: :is a: :i IM 4 -M i K PR PR 3 .29 SP EON E S1LL E Y NT RA J M R C❑ NC PAI CG C T RECEI V� B E N ❑D E G A RAGE S L AB ❑ .I i.- a::.:.: : :.a::: .................................................................................... .. .. ..... PRIM A 12 SPEONK PRE 6 B SE 5 S — K) PR DRILLE D CS M RLD K DEC K [ E T E D X I B AT N :" :::.,:_ :I: : ::i::'. A I❑ N T L STAINLESS STEEL SCRE S L FINISH T RIM DETAIL ::: ::: : : : : :: : :: ::: i::: ........................... ... ........................................................................................ YP A THROUGHOUT A LI NGS T IC L T R R S TAIR R I I N E I H ML❑CK M TH E T EL JS I R ❑ B TAI S N T RI❑R S - -- - - — A E LL I P HA N RAIL 4 D Y T M W/ LJ 6 0 2 T S T O S P O ❑S a . 4 P❑S T :.:.:: TERS AND LJ 000 A US E AN J 53 60 B L ----------------------- ----- ----- -- ------- ----- -- -------- .:;. :.i.-: 1 :i s ,. .:: 1 :�: I —� .. :: :::::::::::::: :::::::.:•:... ' - w AR - •::.•::.1. ..:•::.•. ::. .........::.::1:.. V NEW ,1/2 CLASSIC BEADBO D I T R .CE I E WA 0 E LLS I ti 1 r 1 1 M r 32 HIGH WITF-I CAP�RAIL 8n SHDE ::;::: :*:*':i 1 .:1' :: I I�� I I - T S � �T HR ❑ M C � ALL ❑ R ILE �- B AT ❑ I I - I 1 A SHOWER WALLS T❑ RECIEVE FULL HEIG _ _ _ _ '::::. r-.--•........:....:..:.:..:-.:.--..:.::.. . WALLS LL _ _ -R N TA BY CONTRACTOR ,� •:::.•.:......:::.•.•:::.•:::::.: :•..:.:::::::::.:::.:.:..... WITH NO ✓ELTY STRIP, I S LLED : : :::�:: ALL MATERIALS T❑ ,BE N.I.C.CSEE SCHEDULE) �: .. ::.•. ::.i:•::•: .::::•::•:: ....... I N I T I G V F IL ULL R T❑ RECIE E _ F ❑O S _ R B ATHR00 M L F ❑❑ S L D I— NI LE] [SEE SC E DU I U T NG - - - - - � A AL ILI T NST LL L � ❑ I T R I NT AC 0 CO R I Q z ,. AR N I Cr ��—.c--.r—�c—�Ir—per—�c—�c—�---.c—:c— , AT A E M RI L.S E I ,.-� _ I�t ....................................................................................................... ....................................................................................................... 1 a ................ ................ I. ....... i... H _ �► _ w __ _ U T FNS ES PA N I I / CEI � NG I � 1 H F A T 1 T / L 215) _ _ WH B C P I E S N AM N M❑O RE SU ER N GS BE J I CE ILI I 1 3 I U 1 PRIMER C2) FINISH C❑ATS C ] , Q W R A AV LVE T 319) N N CL❑W LUSTE QU E , AM N MOORE LI E I WALLS BEN J I � N I Q lJ. C1] PRIMER,C2) FINISH CATS P — ------ --- -- b W❑❑DW❑RK BENJAMIry MOORE SUPER WHITE 02 CAQUAPEARL 3101 � ----- —_ --_ -�------ J Q - ORS C11 PRIMER [21 FINISH COATS ------- ____ ! _ __ __ DO — _ WINDOWS ALL INTERIOR TRIM T❑ BE " _—_ ==="T__=_=—_`—__ = = _ _-_ -_ ---- ----_ —- _ --� U W --- - - ==1- -z- I I I �- as TRIM BE MOORE SUPER WHITE 02 _--- _ —"— I I --- 11--- 1— —__ _ Z I W k N❑TE: CONTRACTOIR T❑ ALLOW F❑R MULTIPLE COLOR — ______'-_ _^_ ____ — = I I I IIIIIII B F III p� f— _r_" _ I I I BREAKS,AS INDICATED ❑N FINISH PLAN [AQUAVELVET 319) — "`"`z— - -- - � IIIII I �' `-� I— z -z-_ -_- z-- -7_—_ _7 I I (� �-+ ` CABOTS FACTORY APPLIED BLEACH `—"` '—"-l_ — —_I_ --z---"— -) I I I IIIIII I I � z SIDING — —Z----- -- -- ----- ---- II ° ° III I F EXTERIOR TRIM BENJAMIN M❑ORE EXT HI GLOSS WHITE 00 �___�—_—___ ____�---_=l-_=_J W F__ � --- ---�=------ ---=z==----- -- III III I I o 3 Q = C1) PRIMER,C2) FINISH C❑ATS --z----- I ----- IIIII ° ° IIIIIIII I III w � E— G_ C L ❑ SET / PANTRY CABINETRY ---"_ =r_-: __-_ __r______7-__ III IIIIII _T_____=r-__ 1_______ - =1== - ---- A - -- --- --- -- I I ---- --- ----- --- Q --� o ALL SHELVING/HANGING SYSTEMS/DRAWERS -- '— -- — —"-- _____ —"—_ ___ :_ -1- --�-- - IIIII I I II _---=z==-=r- --__�- � TO BE N.I.C. F❑R L��BOR &MATE.RIALS _____L.___.T_______ ___J_______ - _---- __ _-__— — 3 ---- ----T=---- ---1------ - III F 1 ---- ----T= ----r _f-_-_-I------Z-_-- -----� __1 I I I I I II I I II = --__-- --=-Z=--_-_ \ / . _------===1===--- ====T=_-----'___--. I I I I I I I I I I -- --=- A ---=L---- V I S T A "_z ----T------ ----Z------- ----z=--- I I I I F I I I I I I ------ ------ ' __�_==1____=_`___�_-_===r_= I I I I I I I IIIII _f___T- __-1=-=- = RESIDENTIAL DESIGN ❑ ❑ R / HA �. DWARE SCHEDULE ___ _ ___ _ z---===T===�=_-====j====z== ===T IIIIIIIIIIIIIIIS IIIIIIIII ---=z==---- ------ P.O.B. - 634 DOORS —ALL INTI=RI❑R D❑OR?S TO BE D❑❑RCRAFT CATHERT❑NJ ----�----- --'-1------ --�----- ---"— —'— — _____ ___ -___ ___r_=_____ __ I I I I I I_I_ I I I I _ ____z_=_=r_ ___ __ REMSENBURG 4 PANEL D❑❑R, Pf2OVIDE IMP'RESSI❑N MIRROR SIDE—A OPTION _ ____ l III ____ __-- NEW Y❑RK 11940 FDR SELECTED BATHROOM D❑ERS -- -- — j1=--'-z-----_7-----j— HARDWARE — ALL. DOOR HARDWARE FIRST FL❑❑R T❑ BE EMTEK —r"—"—"—" "1— IzI _____ ____1=_____ ____ WAVERLY KNOB/1.`5 PAIR HINGES W/❑IL RUBBED FINISH . ISSUE FDR CONSTRUCTION DATE i - : '. • .. • • .. . . .. Revisions . . No. Date Description PROVIDE PRIVACY LOCKS FOR ALL BEDROOM/ .:: . • .. . . BATH ENTRY DDORS . . O . . . . . . • .. '.' E HARDWARE FOR PC]CKET AND BI—FOLD D❑ORS TO BE . ' • • . GRANT 1600 SERIES HEAVY DIUTY COMPONENTS . . EXTERIOR DOORS / WINDOWS ANDERSEN [SEE D❑❑R SCHEDULE) B . .• : ., E : .• E . A :' : . . :.. • .. ; KITCHEN / BATH CA► BINETS . ' : - •: KITCHEN/BATH CABINETS/GRANITE TOPS : • • . '. E. APPLIANCES T❑ BE N.I.C. _ : . .. ...'. - . . . . . . - --; esigned y Checked By: . ~ :. roject Nur�berl Drawn By, I :. : .. . f` PLACE . ENCLOSURES - ' . _ . ' FIRE . . . eet itle� . i '. F4 00/EACH OF FIREPLACE ENCLOSURES .T. - : . • . ALLOW ,0 E ' • y .. heet Numb . . SHOWER GLASS / DOORS . . ' . . ... . . .. . . . � . . .. . . �.. . . . . . . . . ALL SHOWER GLASS WALLS/ID❑ORS TO BE • 4 . ' . . . . • ' . . D B .. .. . . .. . ac S/8"[TEMP) FULL HTCU❑N), W/ITH A FRAMELESS INSTALLATION - . . . . • T . . . Q . .. '4. . . ' ..t . 14328 � ST�rE Of NE`tl �O 0 GENERAL NOTES= RTI'3 UPLIFT- 5300 Fl• SOON r2- 3000 C 1, • RTf7 UPLIFT- %51 rl■ 1700 ENDVALL Fe• 170N OiSTS jµ I X\ — RTIO UPlIF1-5851 rt. 17001 Fe- 1704 wL"rNr.11 M �' - BLOCKING RT17 UPPLIFIFT• 11701 LIT11-4 DIJClcI+K, UPLIFT- urLr r.ILMI I- 1701 3 . 170N SECTION A-A HTVT6 r UPLIFT- 9600 PSTAlp each)- 6201 / F - �S4A$, `T� H5E FLOOR BRACING ENDWALL . T3 LSTA12 4 / - 0 D . C . UPLIFT- 620N- UPLIFT- 4751 (each) rl• l50N I re. 1500 R13 UR.RT•IT)- i• P `� CEILING BRACING 7 i IPAHD22 !• •' . UPLIFT• ♦76DN AT GABLE ENDWALL r. I Rn C►LIfT•�a. `••i STf ie.17 7" + UPLIFT- 8251 TDxS F1- 5651 USP ST) SERIE UPLIFT- 80951 re- 650 650N ANCHOR BOLT 4 e x ♦ CONTINUOUS FA3 LATERAL BRACES AT 6' OC. TRUSS OR CEILING ,JOIST . t 11554 rFl.UPLIFT-1 GA BtE END TRUSS re- 7051 a-101 NAILS 173- 65001 i SP STD) SERIES ANCHOR DOLT 10-OD NAILS 50 COOLER NAILS AT IQ' OG 2'x4' BLOCK NAILED TO EACH DRAPE VITH /-IOD NAILS GTPSUN BOARD E STR SD COOLER MAILS AT 7. O.C.W 'INDOW / DOOR TYPICAL RIDGESTUDT ❑ I0_811 NAIL S - ENDVALL STUDS v R - FOUNDATION C ❑ NNECTI ❑ N < HEAD ER C ❑ NNECTI ❑ N C ❑ NNECTI ❑ N RAFTER BRACING @ GABLEED ENDWALL 4 / - 0 D . C . LLl U z RAFTER SPAN- a k S CS R@O ! TEHERCUG�R802.St.S1tl) � QzW o NSTA1 36 RIDGE BOARD z UPLNFT- 16t01 PIRt)N CCBETVEEN BRACES I MINUOIJS [N� ACE Q J � /�--� LFTA6 w `-! UPLIFT- 990N I ..../�. .-. NAIL TO JOIST FI. 700s Fe• 901 ••`1� TOP PLATE CEILINGg.GIST- F- A MTN IwO R802.1C2) v �LIL/— :'PZE� upurr.n" AIEK Td'G BEADED SOFi1T L rI")�Fms a Fl..t690 6901 W/ CONT, VENTING FI- 690 RTs 1aM.r0 3 D Q o 1!•LKT.xxo� y MP♦F QT• i w Fs i �SUDrL00R F IF UPLIFT- 6901 UPLIFT- 9901 FFl I IR W Ft. 70" 3 r2- 901 LBPLIFT" 6" Z VI. 690 HBhG TAPERED 11'S0. COLUMN BEARING VALL GIRDERLJW KLrYA NTv19 UPLIFT- 10201 VISTA . UPLIFT- B660N TINUOUS METAL STRAPPING I Tanie12.5 Z�NE4 RESIDENTIAL DESIGN UPLIFT- 6901 Nailing Requirernelrts for the Fl• 690 Case Study Roof-120-mph, Field 8' O.C. 12"o.c. 3'o.c. 4' o.c. P.O.B. — 634 3-sec Peak Gust,in-Inch- PDMON Edges A"ox. 6"O.C. 3" O.C. 3"o.c. REMSENBURG Thick Roof Sheathing with Bd NEW YORK 11940 Common Nails Phon 1 631-553-0829 Fax 1 631-325- 4 X 8 BEAM HELD BY SIMPSON EPC 68 2XI10 CCA BOLTS POST CAP MATH (2) 5/8 # MOUNTNG BOLTS ISSUE FOR CONSTRUCTION DATE + F INTO POST AND (1) S/8' 0 MOUNTING BOLT I_ INTO BEAM ia[ i°1 Revisions RAFTER TO SILL T ❑T2X1O CCA DECK JOISTS 016. SIMPSON CB 88 COLUMN BASEA � � � ❑ � R � No. DateDescription T Y P I C�, ��� I T G ' FLOOR CONNECTION STUD C ❑ NNECTI ❑ N o � - h; d ,o t 1 GAB C+ ' e M ' ' ^ LE ROOFS P ❑ R C H DETAIL [ SIILARI WALLS 0:510• k K r , wNoaoR++ores F1lOTECTION rAsrElw+c SIMPLIFIED PRESCRIPTIVE BUILDING ENVELOPE MINIMAL THERMAL COMPONENT PERFORMANCE �'r 1'fi'r -1a� � TABLE [1609.1.4 _ rASTENER TYPE 2 FEET D 2FT<OR-4 ♦OR-6FT 8F'T<OR I I , , , �__ SPAN< HEATING DEGREE DAYS [5,500— 5,999] , \ � esigne y= Checked By 2 1/2 16 16'10C ISIOC 12'DC 110c -- wow SCREWS A 0 ; (D , ° (D �� m ; +2'OC ITEM RESISTANCE U-FACTOR ° ^ Project Numbers Drawn Bye 2 1/2 fS 16'DC ID'OC I6'0C WOOD SCREWS WALLS R-18 0.055 RAL STRUCTU ANALY9S PRESCRIPTIVE DESIGN - � � � ,p<eS45• �� � � `� 10"<eS3D' ee 1 eT NANO EXPOSURE CATAGOW - 8 CEILING R-38 0.026 cAaLE ROOFS T-�e[ Sheet Numb bw LIVE SNOW WIND LOAD Lan LOAD LOAD WINDOW R-4 0.40 tOr cea t5• HIP ROOFS ,0•<e 530' DESKty FIRST FL toPsr 2OPSr 40 PSr 1"UPH FLOOR R-21 0.047 LDAos FIRST FTL SECOND FL PORCH DECKS Notes 0-1 feet In at cases novaI I z IT IS MY STATEMENT, THAT THE STRUCTURE IN QUESTION h� 170�` 1305` ` COMPLIES WITH THE REQUIREMENTS OF THE STATE �� E� A rF �C> MFrT OT 2oNE 0 ENERGY CONSERVATION CODE.AS OUTLINED IN fp Q SECTION 601.2.1,AND THE APPLICABLE TABLE OF A � � MINIMAL REQUIRED THERMAL PERFORMANCE 602.1[11Ap , TqT f OF NEB t v