Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
32501-Z
FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-33332 Date: 10/10/08 THIS CERTIFIES that the building NEW DWELLING Location of Property: 5704 INDIAN NECK LA PECONIC (HOUSE NO. ) (STREET) (HAMLET) County Tax Map No. 473889 Section 98 Block 5 Lot 14.3 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated NOVEMBER 1, 2006 pursuant to which Building Permit No. 32501-Z dated NOVEMBER 17, 2006 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ONE FAMILY DWELLING WITH COVERED PORCHES, SCREENED PORCH AND ATTACHED THREE CAR GARAGE AS APPLIED FOR PER ZBA #5895 ISSUED 9/14/6. The certificate is issued to SANDRA ENGELKE (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL R10-06-0021 06/21/07 ELECTRICAL CERTIFICATE NO. 3053914 08/22/08 PLUMBERS CERTIFICATION DATED 07/09/08 PECONIC PLUMBING & HEAT -"'L )- 1-,4 //Ut rized Signature Rev. 1/81 FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-33333 Date: 10/10/08 THIS CERTIFIES that the building ACCESSORY Location of Property: 5704 INDIAN NECK LA PECONIC (HOUSE NO. ) (STREET) (HAMLET) County Tax Map No. 473889 Section 98 Block 5 Lot 14.3 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated NOVEMBER 1, 2006 pursuant to which Building Permit No. 32501-Z dated NOVEMBER 17, 2006 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ACCESSORY IN GROUND SWIMMING POOL WITH TERRACE AND FENCE TO CODE AS APPLIED FOR PER ZBA #5895 ISSUED 9/14/6. The certificate is issued to SANDRA ENGELKE (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A ELECTRICAL CERTIFICATE NO. 3053914 08/22/08 PLUMBERS CERTIFICATION DATED N/A /,,-'�ori,/ed Signature Rev. 1/81 Form No.6 l TOWN OF SOUTHOLD BUILDING DEPARTMENT 1 `I TOWN HALL 765-1802 DEPT. APPLICATION FOR CERTIFICATE OF OCCUPAN T N QF S(`!ITHOLD - This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: l. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Conunercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property shoving all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00, Swimming pool $25.00, Accessory building$25.00, Additions to accessory building $25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy -Residential $15.00, Conunercial $15.00 Date. q-S- (3 New Construction: Old or Pre-existing Building: (check one) z4. Location of Property: S Q O V ILI (��,, { C4t tL L.0-&4._ House No. r Street Harnlet Owner or Owners of Property: Suffolk County Tax Map No 1000, Section Block S Lot 003 Subdivision Filed Map. Lot: Permit No.. 3aS-0l Date of Permit. ff 17 1 64, Applicant: Health Dept. Approval: Underwriters Approval:✓ ti n /3�.+ ,�� �j(� �c.� Planning Board Approval: ' Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ a�.(/J Applicant Signature Qe-� sC)(::,� q8v - - l a �d�Mn�n1-.r��RlVr-P MIVL P�n�n`RPLP��n��[:PL n��n��L����,E1 3 L.n���n���n�n� CEll 5 BY THIS CERTIFICATE OF COMPLIANCE THE 5 5 NEW YORK BOARD OF FIRE UNDERWRITERS 5 5 S 5 BUREAU OF ELECTRICITY 5 5 40 FULTON STREET — NEW YORK, NY 10038 5 CERTIFIES THAT 5 5 S 5 Upon the application of upon premises owned by 5 5 S 5 S 5 G&S ELECTRICAL CONTR. GEORGE ENGELKE SP.O. BOX 215 5704 INDIAN NECK LANE 5 5 SOUTHOLD, NY 11971, PECONIC, NY 11958 c� 5 5 Located at _ 5 5704 INDIAN NECK LANE PECONIC, NY 11958 C, 5 Application Number: 3053914 Certificate Number: 3053914 5 5 c5 5 Section: Block: Lot: Building Permit`32501 BDC:nsl l 5 5 5 5 Described as a Residential occupancy, wherein the premises electrical system consisting of cj 5 electrical devices and wiring, described below, located in/on the premises at: 5 5 Basement,First Floor;Second Floor,Attached Garage,Outside,Pool/Spa,Porch/Deck, 5 5 SA visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed 5 5 herein, was conducted in accordance with the requirements of the applicable code and/or standard 5 promulgated by the State of New York, Department of State Code Enforcement and Administration, or other 5 5 authority having jurisdiction, and found to be in compliance therewith on the22nd Day of August, 2008. 5 5 Name OTY Rate Refine Circuits Tyne 5 5 AdditionalCharges C, 5 -50a steam unit 5 5 Alarm and emergency equipment 5 Sensor 4 0 0 Carbon Monoxide 5 5 Appliances and Accessories �e' 5 Air Conditioner 6 0 Above 1500 BTU 5 5 Dish Washer 1 0 1.2 KW 5 Exhaust Fan 6 0 F.H.P 5 Furnace 2 0 Oil 5 5 Pool/Spa Bonding 1 0 5 Pool Heater 1 0 Gas 5 5 Time Clock Switch 2 0 pool 5 Panels 5 1 50 7 5L 5 Service C.7' 5 Service Disconnect: 0 200 cb 5 5 Servicel Phase3w Service 5 5 Rating400Amperes Seal SContinued on Next Page 1 of 2 5 5 5 5 5 5 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. 5 5 o LPLPL������������������������������������������������������������ o � c.I�r�rJ��J'rJrt�frJ�rJ�rJ�rJ�r�cPrJ�rJ�rJ��rJ�cPr.J�c1rJ'�rJ'�l'cPrJ�r�rJ�r�r�rJrlcPrJ�rJ7cPrJ'cPrJ�cPrJ�r�rJ�r..J�rJ�r.PrJ�rJ�rJ�rJr�rJ�rJ�rJ�rJ�rJ�r�cJ�rJ�rJ�r.1�rJ� c0 5 BY THIS CERTIFICATE OF COMPLIANCE THE 5 S NEW YORK BOARD OF FIRE UNDERWRITERS 5 5 S 5 BUREAU OF ELECTRICITY 5 5 40 FULTON STREET — NEW YORK, NY 10038 c� 5 CERTIFIES THAT 5 S S 5 Upon the application of upon premises owned by 5 5 5 5 5 G&S ELECTRICAL CONTR. GEORGE ENGELKE 5 P.O. BOX 215 5704 INDIAN NECK LANE 5 SSOUTHOLD, NY 11971, PECONIC, NY 11958 5 5 Located at 5704 INDIAN NECK LANE PECONIC, NY 11958 5 5 5 Application Number: 3063914 Certificate Number: 3053914 5 5 C5 5 Section: Block: Lot: Building Permit: 32501 BDC' ns11 5 5 5 5 Described as a Residential occupancy, wherein the premises electrical system consisting of 5 5 electrical devices and wiring, described below, located in/on the premises at: CS, 5 Basement,First Floor,Second Floor,Attached Garage,Outside,Pool/Spa,Porch/Deck, L� 5 5 5 A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed rj 5 herein, was conducted in accordance with the requirements of the applicable code and/or standard 5 5 promulgated by the State of New York, Department of State Code Enforcement and Administration, or other 5 5 authority having jurisdiction, and found to be in compliance therewith on the 22nd Day of August, Zoos. 5 5 Name OTY Rate Rating Circuits Tvoe c5 (� Wiring And Devices 5 5 Dimmer 3 0 120 V 5 Fixture 2 0 pool Incandescent 5 Fixture 8 0 Low Voltage 5 Fixture 144 0 Incandescent 5 5 Outlet 20 0 Gen,Purpose �5] 5 Outlet 152 0 Fixture 5 Paddle Fan 9 0 5 Receptacle 1 0 pool GFCI 5 5 Receptacle 2 0 20a-pool Special/twist lock 5 Receptacle 3 0 20a-laundry Appliance 5 5 Receptacle 3 0 30a Dryer 5 5 Receptacle 19 0 GFCI 5 5 Receptacle 119 0 Gen,Purpose 5 5 Switch 126 0 Gen,Purpose 5 5 5 5 5 5 seal 5 2 of 2 5 5 5 5 S 5 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. 5 5 5 aP !C.PLCPLL� . . . P. . . IIC��� oCPPCn1Lof[ �C �� I �P�I� .� JC2 . C. : .IC �LI��C.I�[.I�G1CJ�C.I�C.I�L(� 0 o�osuFFot,��o o� Gyp H 2 Town Hall,53095 Main Road p Fax(631)765-9502 P.O. Box 1179 y�0 ��� Telephone(631)765-1802 Southold,New York 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATION Date: Building Permit No. �13 Owner: S2 (please printy Plumber: Pc e r'n i'� R iv- (please print) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. lumbers Si a Sworn to before me this d y of 2,0 0!9 LC Notary Public, S!k zW ffT County L.LOPR Notary Public it cc,,State of Now YDtk No.01 L06070081 Qui n i Suftal Commission Expires r James F. King, President pF so�ryo Town Hall Jill M. Doherty,Vice-President ,`O l0 53095 Route 25 Peggy A. Dickerson P.O.Box 1179 Southold, New York 11971-0959 Dave Bergen N Bob Ghosio,Jr. �l� �Q Telephone(631) 765-1892 OU Fax(631) 765-6641 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD CERTIFICATE OF COMPLIANCE (REVISED 10/10/08) # 0331C Date October 10, 2008 THIS CERTIFIES that the removal of the existing residence, cottagegarage, and construction of a new residence, pool, terraces and sanitary system At 5704 Indian Neck Lane, Peconic Suffolk County Tax Map #98-5-14.3 Conforms to the application for a Trustees Permit heretofore filed in this office Dated 3/17/06 pursuant to which Trustees Wetland Permit#6364 Dated 5/17/06 was issued, and conforms to all of the requirements and conditions of the applicable provisions of law. The project for which this certificate is being issued is for the removal of the existing residence, cottage and garage, and construction of a new residence,pool, terraces and sanitarysystem. The certificate is issued to GEORGE & SANDRA ENGELKE owner of the aforesaid property. )XP"- Authorized Signature FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 32501 Z Date NOVEMBER 17, 2006 Permission is hereby granted to: SANDRA ENGELKE 83 CHELSEA RD GARDEN CITY,NY 11530 for DEMOLITION OF A DWELLING, GARAGE AND COTTAGE, CONSTRUCTION OF A NEW DWELLING AND ISP AS PER ZBA, SCHD, DEC AND TRUSTEES AS APPLIED FOR 2COS REQ at premises located at 5704 INDIAN NECK LA PECONIC County Tax Map No. 473889 Section 098 Block 0005 Lot No. 014 . 003 pursuant to application dated NOVEMBER 1, 2006 and approved by the Building Inspector to expire on MAY Fee $ 4, 109 .45 uth6ri d Signatu ORIGINAL Rev. 5/8/02 PEALS BOARD MEMBERS �F SO!/T ,1 •. Mailing Address: Ruth D. Oliva,Chairwoman �� �plo Southold Town Hall Gerard P. Goehringer 53095 Main Road -P.O.Box 1179 Southold,NY 11971-0959 James Dinizio,Jr. CA AcOffice Location: Michael A. SimonO ,A�aa�� Town Annex/First Floor,North Fork Bank Leslie Kanes Weisman IyCQUMN,�`�'' 54375 Main Road(at Youngs Avenue) Southold,NY 11971 http://southoldtown.northfork.net ZONING BOARD OF APPEALS TOWN OF SOUTHOLD Tel. (631)765-1809-Fax(631)765-9064 FINDINGS, DELIBERATIONS AND DETERMINATION MEETING OF SEPTEMBER 14, 2006 ZB File No. 5895—George and Sandra Engelke Property Location: 5704 Indian Neck Lane, Peconic CTM 98-5-14.3 SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this application and determines that this review falls under the Type II category of the State's List of Actions, without further steps. PROPERTY FACTS/DESCRIPTION: The applicants' 2.99-acre parcel is improved with an existing one-story dwelling and two accessory buildings (one formerly containing a temporary family cottage). The property measures 172.66 feet in width along Hog Neck Bay.and 878 feet in depth to the mean high tide mark, measured from the 30 ft' wide right-of-way at the north end of the premises, shown on the October 20, 2004 survey, revised February 23, 2006 by John T. Metzger, L.S. BASIS OF APPLICATION: The applicant requests Variances under Sections 100-33 (280-15) and 100-239.4E (280-116), based on the Building Inspector's March 20, 2006 Notice of Disapproval, amended June 5, 2006, concerning new construction, after substantial demolition of the existing dwelling, expansion, proposed covered-porch areas, proposed swimming pool, proposed accessory building referred to as 'beach house' proposing nonconforming, minimum setbacks as follow: (a) 68'8" from the new dwelling/covered porch to the existing wood bulkhead; (b) 47'6" from the new swimming pool structure to the existing wood bulkhead, (c) 1'3" to the side lot line and 27'6" to the bulkhead from the new accessory building, (d) new outdoor shower structure at zero setback from the side lot line. The minimum setbacks required by Town Code for all buildings and structures are: (1) 75 feet from the bulkhead, and (2) 20 ft. minimum from the side lot line. FINDINGS OF FACT The Zoning Board of Appeals held a public hearing on this application on August 31, 2006, at which time written and oral evidence were presented. Based upon all testimony, documentation, personal inspection of the property, and other evidence, the Zoning Board finds the following facts to be true and relevant: VARIANCE RELIEF REQUESTED: The owners propose to demolish substantially more than 50 percent of the pre-existing nonconforming house structure, after building the principal building in another location, and requesting use of the replacement building as an accessory use/beach house Page 4—September 14,2006 7R Film Mn RAW;—(.`.nnrnn onri Q�ndr� Fn. M— // Page 2—September 14,2006 ZB File No.5895—George and Sandra Engelke CTM No.98-5-14.3 building with a screened porch, toilet room, sink, wet bar, and an outdoor shower and deck, at a minimum of 1'3" from the side lot line, instead of the code-required 20 ft. minimum, and 27'6" from the bulkhead instead of 75 feet. Also proposed is a new principal dwelling (+/-96' long by 98' in depth), and accessory swimming pool at-less than the code required 75 feet from the existing bulkhead. TOWN CODE CHAPTER 95 (268) LWRP DETERMINATION: The applicants are requesting a new dwelling and accessory swimming pool construction in a new location, set back less than the code- required 75 feet minimum from the bulkhead and 100 feet minimum from the top of the bluff. A Determination of Inconsistency was issued under Chapter 95, Waterfront Consistency Review of the Town of Southold Code and Local Waterfront Revitalization Program (LWRP) standards. Grant of alternative relief in this variance application will substantially increase the setback measured between the new dwelling and the bulkhead to a minimum of 80 feet for new construction, and denies the applicants requests for substantial variance relief. The alternative relief granted herein will meet code minimum requirements at least 100% for the new dwelling location, 100% for a new accessory beach building, and at least 78% for a location of a new swimming pool, under the strict requirements of Section 280-116 (100-239.4B) of the zoning code. All new construction, with the exception of the accessory swimming pool, will be required to conform to the Zoning Code minimum standards applicable on a parcel containing 2.9 acres and 172.66 feet in width (measured at the waterfront/bulkhead). Since the existing structures on. the subject property are being dramatically reconstructed as proposed, it is,reasonable to eliminate the extreme non-conformity of the existing house and require the greatest reasonable degree of conformity with the Zoning regulations, as well as the LWRP, which mandates the highest standards of coastal erosion/wetland/water bodies protection approved by New York State and Southold Town. REASONS FOR BOARD ACTION: On the basis of testimony presented, materials submitted and personal inspections, the Board makes the following findings: 1. Grant of alternative relief will not produce an undesirable change in the character of the neighborhood or a detriment to nearby properties. Zoning Code Section 100-239.4A (280-116) was enacted in 1985. The applicants' property is large, containing 2.97 acres, and alternative locations further landward on this site is available for both new buildings (main dwelling and the accessory beach house without living area), other than the closer setbacks proposed from the bulkhead and side lot line, requested as close as 1'3". The property contains an older home in need of major repairs, and which building is proposed to be substantially demolished - except that the applicants wish to keep only a small deck structure. The applicants desire to build a new, enlarged home in a location 68'8" from the bulkhead instead of the minimum 75 feet required under Zoning Section 100- 239.4E (280-116) will produce an undesirable change in the character of the neighborhood and detriment to nearby properties. Both new buildings as proposed will be substantially larger than those existing on adjacent properties. The swimming pool, however, should have little visual impact given the setback from the bulkhead will be more landward than those built in nonconforming locations prior to 1985. After increasing the proposed +/-96 ft. wide principal dwelling to a minimum 80 ft. setback from the bulkhead, this board will allow a variance considerably reducing the setback for an inground accessory swimming pool at a minimum of 59 feet from the bulkhead, instead of the requested 466". An increased setback for a Af Ce3—September 14,2006 ZB File No. 5895—George and Sandra Engelke CTM No.98-5-14.3 new dwelling at 80 feet from the bulkhead will be conforming to the code requirements and will permit a variance for a swimming pool, reducing the bulkhead setback substantially at 59 feet for the swimming pool, instead of the code-required 75 feet, while at the same time providing other areas on this site for building, in conformity with the Zoning Code. 2. The benefit sought by the applicants can be achieved by alternative relief for the swimming pool, and can be achieved for the main dwelling and proposed beach house building without the need for a variance. The applicants propose a new principal dwelling in a new location on this site substantially larger than homes in the area, and the proposed accessory beach building is proposed to be converted from. an existing "deck" which would remain after substantially demolishing the remainder of the older existing building (nonconforming house). Although there are overhead wires that exist at least 200 feet from the bulkhead, this 2.979 acre lot.contains considerable available land area for siting the new buildings to meet the current code setbacks. 3. The alternative relief granted is substantial. The requested nonconforming setbacks are not the minimum necessary for a parcel that contains 2.79 acres of lot size. Article XXIII, Section 100- 239.41B (280-116) requires a minimum 75-foot setback from the existing bulkhead on a waterfront parcel. The proposed accessory beach house is requested at only 27.5 feet from the bulkhead and only.1.25 feet from the side yard. The proposed accessory swimming pool is requested at only 47.5 feet from the existing bulkhead with a 25' westerly side yard, and the proposed covered porch on the south elevation (seaward side) of the proposed new dwelling is requested at only 68'8" from the existing bulkhead. The reduction of setbacks requested by the applicants for the new construction varies between 98.7% and 9% from the code requirement. 4. The difficulty claimed is self-created, since the new principal dwelling and accessory building could be sited to meet conforming setbacks since the subject parcel is 2.9 acres and the overall dimensions of the principal building is shown at 96+/- feet wide by 98+/- deep along the west side as designed with the garage and extended areas shown on the April 18, 2006 site plan, revised 6/20/06 by Samuels & Steelman, R.A. 5. No evidence has been submitted to suggest that the proposed new construction will not have an adverse impact on physical or environmental conditions in the neighborhood. The proposed beach house, principal dwelling and accessory swimming pool are proposed in locations that will be substantially non-conforming at less than 75 feet from the bulkhead, and only 23 feet from the top of the bluff for excavation of the in-ground swimming pool and 68'8' for the dwelling, contributing to erosion. The bluff has an 8 ft. drop in land contour, seaward and toward the tidal area and adjacent bulkhead. 6. Grant of alternative relief is the minimum action necessary and adequate to enable the applicant to enjoy the benefit of a new principal dwelling, accessory swimming pool and accessory building, while preserving and protecting the character of the neighborhood and the health, safety and welfare of the community. RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing test under New York Town Law 267-B, motion was offered by Member Weisman, seconded by Chairwoman Oliva, and duly carried, to 471 Page 4-September 14,2006 //I ZB File No.5895-George and Sandra Engelke 4 CTM No.98-5-14.3 DENY the relief as applied for in its entirety (beach house etc); and grant the following alternative relief: 1. After demolition of the existing nonconforming house, new construction of same shall meet the zoning code requirements with conforming setbacks from bulkhead and property lines. The replacement of existing nonconforming house, as requested, is denied for the requested accessory beach house structure. 2. The proposed accessory swimming pool and related pool equipment shall be no closer than 59 feet to the existing bulkhead. 3. Locate the proposed principal dwelling no closer than 80 feet to the existing bulkhead. 4. An adequate cistern well shall be installed landward of pool for proper discharge of pool water and drainage. Any deviation from the variance given such as extensions, or demolitions which are not shown on the applicant's diagrams or survey site maps, are not authorized under this application when involving nonconformities under the zoning code. This action does not authorize or condone any current or future use, setback or other feature of the subject property that may violate the Zoning Code, other than such uses, setbacks and other features as are expressly addressed in this action. The Board reserves the right to substitute a similar design that is de minimis in nature for an alteration that does not increase the degree of nonconformity. Vote of the Board: Ayes: Members Oliva (Chairwoman), Goehringer and Weisman. This Resolution was duly adopted (3-0). Ruth D. Oliva 10/1 /06 Approved for Filing a oF souryolo coutom,��' TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSU ION [ ] FRAMING /STRAPPING [ INAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESIST CONSTRUCTION [ ] FIRE RESISTANT PENETRATION MARKS: Ae DATE f OE INSPECTOR hO��OF SOUryolo a� UMY,O�Q TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL ,PEPLA[ ] FI CE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ FIRE RESISTANT CONSTRUCTION [ ] FIRE RE STANT PENETRATION REMARKS: DATE INSPECTOR Of SO�jyo�o coumNc� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION fvj0 REMARKS: '� `"'� a 0 7t, r DATE INSPECTOR hO��OF SOUryo�o �- , • �o ��'YOOUMV,N� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST XROUGH PLOG. [ ] FOUNDATION 2ND [ ] INSULATION =FRAMINGSTRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: DATE I r ® �� 7 - INSPECTOR SO(/jy�lo courm,��' TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION >�FRAMING(S:T:RAP:Pl FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: r DATE ���-d INSPECTOR Of SOUl��lo Coumv, TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION FRAMING /STRAPPING [ ] FINAL [ \] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: Lys✓�L r Cad e i � c� r DATE s- ( — 0 7 INSPECTOR TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ]�DATION 1ST [ ] ROUGH PLBG. [ FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ) FIRE RESISTANT PENETRATION f REMARKS: z DATE INSPECTOR .� rjf SO(/ryolo 3 couto,� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION KI FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: DATE _ - INSPECTOR-"' ' 1 J FIELD INSPECTION REPORT DATE COMMENTS A' A FOUNDATION(1ST) 'v --� y ------------------------------------- FOUNDATION(2ND) c� z ROUGH FRAMING& PLUMBING -k�r _ r -- - INSULATION PER N.Y. STATE ENERGY CODE Y f` & iZ s FINAL 040 Al ADDITIONAL COMMENTS \�` (o cY. ' y� o z o� a o � G ro 4� y 1 .. ..., - .VV.111ViJ" bU1LDINU F1fKM1l'APYL1UAT1UN CliECKL1S1 BUILDING DEPARTMENT Do you have or need the following,before applying; TOWN HALL Board of Health SOUTHOLD,NY 41971 3 sets of Building Plans TEL: (631) 765=1802 Planning Board approval FAX: (631) 765-9502 Survey . www. northfork.net Southold/ PERMIT NO. L Check Septic Form N.Y.S.D.E.C. if � � Trustees Examined ,20 Contact: Approved it A71 20 Mail to: Disapproved a/c Phone: Expiration 120 C g I ° " ctor APPLICATION FOR BUILDING PERMIT Date20 INSTRUCTIONS �1a,\This pplicatiop,MJUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans, acc rate Jof�-Win sew, Fee according to schedule. .'Plot harsh ocation of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, an wa ays. c.The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue.a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. ` e.No building shall be occupied or used in whole or in part for.any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk,County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (S ature of applicant or.name,if a corporation) (Mailing address of applicant) ' -9 "fry State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder Name of owner of premises : (�., lZ,ORA— QE�ae,126Z (As on the tax roll or latest deed) If applicant is a corporation, signature of duly.4ut}ori2ed officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: 7 �� - House Number Street Hamlet County Tax Map No. lOQO Section /46 Block Lot Subdivision Filed Map No. Lot (Name) 1 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy 49�r b. Intended use and occupancy % �L, ,/��1��/ �c / -�'rfooL 3. Nature of work (check which applicable): New Building ✓ Addition Altefation Repair Removal Demolition Other Work ,2-100 jtlj CkIaDC, 4. Estimated Cost ©©D, 0(�o Fee (Descripti n) (To be-paid on filing this application) 5. If dwelling, number of dwelling units / Number of dwelling units on each floor If garage, number of cars : 6. If.business, commercial or mixed occupancy, specify naturevaud extent of each type of use. 7. Dimensions of existing structures, if any: Front Depth Height Number of Stories_ Dimensions of same structure with alterations or additions: Front Rear Depth Height1 -Number of Stories 8. Dimensions of entire new construction: Front U�� Rear Depth 97 Height__ Number of Stories 9. Size of lot: Front Rear f 7 Z Depth P-� 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated_ K, 9,n .12. Does proposed construction violate any zoning law, ordinance or regulation? YES � NO :3. Will lot be re'-graded? YES NO Will excess fill be removed from premises? YES NO !� �y � ( � A, Names of.Owner of premises S'fCr•�i�E.Address 15 ✓C--1( 'F4 Phone No. Name of Architect - , - t /JAddress 2�'Z35 &4tiL) P—D Phone No 722A6405 Name of Contractor j-:31F4.7WA /?,M/41 Address Phone No. 5; (SrT-f 5 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 6. Provide survey, to scale, with accurate foundation plan and distances to property lines. 7. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. TATE OF NEW YORK) SS: :OUNTY OF �b-ding.duly sword;:deposes and says that.,(s)he is the-applicant (Name of individual signing contract) above named, i)He is the (Contractor,Agent, Corporate Officer, etc.) f said owner or owners,.and is duly authorized to perform or have performed the said work and to make and file this application; :at all statements contained in this application are true to the best of his knowledge and belief, and that the work will be srformed in the manner set forth in the application filed therewith. worn to before me this �- day of v 206 Notary Publi Signature of Applicant PA%jC-,1A RICH.ABCs notary Public, State of New York No. 0'I R16042467 Qualified in Suffolk County Commission Expires May 30, 20W \ ' � l LETTER OF AUTHORIZATION Sandra & George Engelke 83 Chelsea Road Garden City, NY 11530 516 741-2864 January 12, 2006 We hereby authorize Nancy Steelman of SAMUELS&STEELMAN ARCHITECTS to act as ouragent in obtaining all permits required by SOUTHOLD TOWN,SUFFOLK COUNTY and NEW YORK STATE for the construction of our residence at 5704 Indian Neck Lane in Peconic, NY Geoge Engelk Date Sandra Engelke Date S A M U E L S & S T E E L M A N .November 1, 2006 Building Department Town Hall Southold, NY 11971 Re: The Engelke Residence 5704 Indian Neck Ln. Peconic, New York Attn: Mike Verity Enclosed please find materials required for application for a BUILDING PERMIT for the above referenced project, including: 1. Building Permit Application 2. Four (4) sealed sets Construction Drawings 3. Sealed Survey 4. SCDHS Sanitary Permit 5. DEC, NJR 6. Southold Town Trustees Permit 7. Southold ZBA Determination 8. Southold Town Sanitary Permit, 9 REScheck Energy Calculation 10 Window and Door Schedule 11 Letters of Authorization 12. Check for $150.00 Please review the enclosed and get back to me with any questions or concerns. If complete, please prepare a building permit, and notify my office regarding the total fee for that service. Thank you, Nancy Ste man, R.A. Samuels & Steelman Architects encs. ARCHITECTS 25235 MAIN ROAD CUTCHOGUE,NEW YORK 11935 (631)734-6405 FAX(631)734-6407 New York State Department of Environmental Conservation Division of Environmental Permits, Region One Building 40-SUNY, Stony Brook, New York 11790-2356 Phone: (631)444-0365 • FAX: (631)444-0360 Website: www.dec.state.ny.us Denise M.Sheehan Commissioner LETTER OF NON JURISDICTION-ARTICLE 25 George& Sandra Engelke March 15, 2006 83 Chelsea Road Garden City,NY 11530 Re: Application#1-4738-03566/00001 Engelke Property, SCTM# 1000-98-5-14.3 Dear Mr. And Mrs. Engelke: Based on the information you have submitted the Department of Environmental Conservation has determined that the property landward of the topographic of the bluff as shown on the survey prepared by John T Metzger dated Feb 23, 2006, is beyond Article 25 (Tidal Wetlands Act) jurisdiction. Therefore, in accordance with the current Tidal Wetlands Land Use Regulations (6NYCRR Part 661)no permit is required. Be advised, no construction, sedimentation, or disturbance of any kind may take place seaward of the tidal wetlands jurisdictional boundary, as indicated above, without a permit. It is your responsibility to ensure that all precautions are taken to prevent any sedimentation or other alteration or disturbance to the ground surface or vegetation within Article 25 jurisdiction which may result from your project. Such precautions may include maintaining adequate work area between the tidal wetland jurisdictional boundary and your project(i.e. a 15'to 20'wide construction area) or erecting a temporary fence,barrier, or hale bay berm. Please note that this letter does not relieve you of the responsibility of obtaining any necessary permits or approvals from other agencies or local municipalities. Sincerely, Mark Carrara Deputy Permit Administrator cc: Nancy Steelman, R.A. MHP file Southold Town Trustees ,, .:• Board Of South a« SOUTHOLD, NEW YORK DATE: ,May 17, 2006 : • PERMIT NO. ...C/1:3(��- ............. _ GEORGE AND SANDRA ENGELKE ISSUED TO ................................................................................ r Pursuant to. the provisions of Chapter 615 of the Laws of the.State of New York, 1893; and Chapter 404 of the Laws of-the 1 State of New York 1952; and the Southold Town Ordinance en- titled ."REGULATING AND TME.-PLACIN.G..OF:..OB.STRUCT.IQNS. IN AND ON TOWN WATERS AND PUBLIC- LANDS and'-the REMOVAL OF SAND, GRAVEL OR OTHER MATERIALS.A10M LANDS UNDER TOWN•WATERS;'.' and in. accordance with•the Resolution of The Board adopted at a meeting held on May :1 L...•_._ 2006, and in consideration of the sum of $.25.0_10.1......... paid by George and Sandra En elke ........d...•........•...•....•...••••.g•..•...•._•.....•.............._...................................... ..... of Peconic bje .................... ................................. N. Y. and subject to. the Terms and Conditions listed on the reverse side hereof, of Southold Town Trustees authorizes and permits the following: 1Netland Permit to remove an existing residence,cottage and garage.Construct new rdsidence,pool,terraces and r sanitary system,and renovate the existing house into a beach house and all as depicted on the plans prepared by Samuels and Steelman Architects revised May 30,2006. all in 'accordance with the detailed specifications as presented in •the originating application. IN WITNESS WHEREOF, The said Board of Trustees hiere- by causes its Corporate Seal to be affixed, and these presents to scri be subbed by a majority of .the said:Board .as of this data. m o �H • i, v G James F.King,President �*OF S��ro Town Hall Jill M.Doherty,Vice-President �® yl0 53095 Route 25 P.O.Box 1179 Peggy A.Dickerson Southold,New York 11971-0959 Dave Bergen G �� Tele John Holzapfel phone(631)765-1892 Q IyCOUN,n'�� Fax(631)765-6641 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD May 17, 2006 Ms. Nancy Steelman Samuels & Steelman Architects 25235 Main Rd. Cutchogue, NY 11935 RE: GEORGE & SANDRA ENGELKE 5704 INDIAN NECK LANE, PECONIC SCTM#98-5-14.3 Dear Ms. Steelman: The Board of Town Trustees took the following action during its regular meeting held on May 17, 2006 regarding the above matter: WHEREAS, Samuels & Steelman Architects on behalf of GEORGE & SANDRA ENGELKE applied to the Southold Town Trustees for a permit under the provisions of Chapter 97 of the Southold Town Code, the Wetland Ordinance of the Town of Southold, application dated March 17, 2006, and, WHEREAS, said application was referred to the Southold Town Conservation Advisory Council and to the Local Waterfront Revitalization Program Coordinator for their findings and recommendations, and, WHEREAS, a Public Hearing was held by the Town Trustees with respect to said application on May 17, 2006, at which time all interested persons were given an opportunity to be heard, and, WHEREAS, the Board members have personally viewed and are familiar with the premises in question and the surrounding area, and, WHEREAS, the Board has considered all the testimony and documentation submitted concerning this application, and, WHEREAS, the proposal complies with the standards set forth in Chapter 97 of the Southold Town Code, WHEREAS, the Board has determined that the project as proposed will not affect the health, safety and general welfare of the people of the town, NOW THEREFORE BE IT RESOLVED, that the Board of Trustees approve the application of GEORGE & SANDRA ENGELKE to remove an existing residence, cottage and garage. Construct new residence, pool, terraces and sanitary system, and renovate the existing house into a beach house and all as depicted on the plans prepared by Samuels and Steelman Architects revised May 30, 2006. Permit to construct and complete project will expire two years from the date the permit Is signed. Fees must be paid, if applicable, and permit issued within six months of the date of this notification. Inspections are required at a fee of$50.00 per inspection. (See attached schedule.) This is not a determination from any other agency. Fees: $100.00 Very Truly Yours, James F. King President, Board of Trustees JFK/hkc `i Permit# Permit Date REScheck Software Version 3.7.3 Compliance Certificate Project Title: ENGELKE RESIDENCE Report Date:11/01/06 Data filename:Z:\Common autocad files\ACTIVE PROJECTS\Engelke\Energy Calculations.rck Energy Code: New York State Energy Conservation Construction Code Location: Suffolk County,New York Construction Type: Detached 1 or'2 Family Heating Type: Non-Electric Glazing Area Percentage: 20% Heating Degree Days: 5750 Construction Site: Owner/Agent: Designer/Contractor: 5704 Indian Neck Lane SANDRA AND GEORGE ENGELKE Nancy Steelman Peconic,NY 11958 83 CHELSEA ROAD Samuels&Steelman Architects GARDEN CITY,NY 11530 25235 Main Road Cutchogue,NY 11935 631 734 6405 IN - . �•. Ceiling 1:Flat Ceiling or Scissor Truss: 1452 30.0 2.0 48 Ceiling 2:Flat Ceiling or Scissor Truss: 467 30.0 3.0 15 Ceiling 3:Cathedral Ceiling(no attic): 1274 30.0 ° 2.0 41 Wall 1:Wood Frame, 16"o.c.: 308 19.0 2.2 15 Window 1,Ex2:Wood Frame:Double Pane with Low-E: 32 0.340 11 Wall 2:Wood Frame,16"o.c.: 374 19.0, 2.2 17 Window 2,Cx2:Wood Frame:Double Pane with Low-E: 30 0.340 10 Window 3,Jx2:Wood Frame:Double Pane with Low-E: 36 0.340 12 Wall 3:Wood Frame,16"o.c.: 96 19.0 2.2 5 Wall 4:Wood Frame, 16"o.c.: 396 19.0 2.2 19 Door 1,115:Glass: 62 0.280 17 Wall 5:Wood Frame,16"o.c.: 96 19.0 2.2 5 Window 4,T:Wood Frame:Double Pane with Low-E: 7 0.340 2 Window 5,O:Wood Framebouble Pane with Low-E: 4 0.340 1 Wall 6:Wood Frame,16"o.c.: 220 19.0 2.2 11 Window 6,Q:Wood Frame:Double Pane with Low-E: 26 0.340 9 Wall 7:Wood Frame, 16"o.c.: 176 19.0 2.2 8 Window 7:Wood Frame:Double Pane with Low-E: 16 0.340 5 Door 2,118:Glass: 21 0,200 4 Wall 8:Wood Frame,16"o.c.: 176 19.0 2.2 8 Door 3,119:Solid: 21 0.300 6 Door 4,219:Solid: 21 0.300 6 Wall 9:Wood Frame,16"o.c.: 248 19.0 2.2 12 Window 8,E.x2:Wood Frame:Double Pane with Low-E: 32 0.340 11 Wall 10:Wood Frame,16"o.c.: 197 19.0 2.2 7 Door 5,127:Glass: 21 0.340 7 Door 6,128:Glass: 48 0.340 16 ENGELKE RESIDENCE Page 1 of 8 Wall 11:Wood Frame,16"o.c.: 152 19.0 2.2 6 Door 7,129:Glass: 48 0.340 16 Wall 12:Wood Frame,16"o.c.: 193 19.0 2.2 5 Door 8,130:Glass: - 96 0.340 33 Wall 13:Wood Frame,16"o.c.: 96 19.0 2.2 .5 Window 9,K:Wood Frame:Double Pane with Low-E: 7 0.340 2 Wall 14:Wood Frame,16"o.c.: 308 19.0 2.2 8 Window 10,L:Wood Frame:Double Pane with Low-E: 64 0.340 22 Door 9,101:Glass: 48 0.340 16 Door 10,102:Glass: 48 0.340 16 Wall 15:Wood Frame, 16"o.c.: 96 19.0 2.2 5 Window 11,K:Wood Frame:Double Pane with Low-E: 7 0.340 2 Wall 16:Wood Frame,16"o.c.: 352 19.0 2.2 12 Window 12,N:Wood Frame:Double Pane with Low-E: 25 0.340 9 Window 13,N:Wood Frame:Double Pane with Low-E: 25 0.340 9 Door 11, 103:Glass: 48 0.340 16 Door 12,104:Glass: 48 0.340 16 Wall 17:Wood Frame,16"o.c.: 203 19.0 2.2 10 Window 14,F:Wood Frame:Double Pane with Low-E: 32 0.340 11 Wall 18:Wood Frame,16"o.c.: 368 19.0 2.2 18 Window 15,A:Wood Frame:Double Pane with Low-E: 13 0.340 4 Window 16,F:Wood Frame:Double Pane with Low-E: 32 0.340 11 Wall 19:Wood Frame,16"o.c.: 107 19.0 2.2 5 Window 17,H:Wood Frame:Double Pane with Low-E: 20 0.340 7 Wall 20:Wood Frame,16"o.c.: 371 19.0 2.2 17 Window 18,I:Wood Frame:Double Pane with Low-E: 62 0.340 21 Wall 21:Wood Frame,16"o.c.: 107 19.0 2.2 5 Window 19,H:Wood Frame:Double Pane with Low-E: 20 0.340 7 Wall 22:Wood Frame,16"o.c.: 317 19.0 2.2 16 Window 20,F:Wood Frame:Double Pane with Low-E: 32 0.340 11 Wall 23:Wood Frame,16"o.c.: 148 19.0 2.2 6 Window 21,F:Wood Frame:Double Pane with Low-E: 32 0.340 11 Wall 24:Wood Frame,16"o.c.: 122 19.0 2.2 7 Wall 25:Wood Frame,16"o.c.: 217 19.0 2.2 9 Window 22,G:Wood Frame:Double Pane with Low-E: 48 0.340 16 Wall 26:Wood Frame,16"o.c.: 108 19.0 2.2 5 Window 23,H:Wood Frame:Double Pane with Low-E: 20 0.340 7 Wall 27:Wood Frame, 16"o.c.: 371 19.0 2.2 16 Window 24,M:Wood Frame:Double Pane with Low-E: 79 0.340 27 Wall 28:Wood Frame,16"o.c.: 108 19.0 2.2 5 Window 25,H:Wood Frame:Double Pane with Low-E: 20 0.340 7 Wall 29:Wood Frame;16"o.c.: 396 19.0 2.2 18 Window 26,G:Wood Frame:Double Pane with Low-E: 48 0.340 16 Window 27,F:Wood Frame:Double Pane with Low-E: 32 0.340 11 Basement Wall 1:Solid Concrete or Masonry: 3170 0.0 13.0 276 Floor 1:All-Wood Joist/Truss:Over Unconditioned Space: 3170 19.0 2.6 133 Floor 2:All-Wood Joist/Truss'.Over Outside Air: 48 30.0 1.9 1 The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her kno%dedge,belief,and professional judgment,such plans or specifications are in compliance with this Code. TVALAa g"Ak&k fat Builder/ esigner Company Name D to ENGELKE RESIDENCE Page 2 of 8 I! REScheck Software Version 3.7.3 F� Inspection Checklist Date: 11/01/06 Ceilings: ❑ Ceiling 1:Flat Ceiling or Scissor Truss,R-30.0 cavity+R-2.0 continuous insulation Comments: ❑ Ceiling 2:Flat Ceiling or Scissor Truss,R-30.0 cavity+R-3.0 continuous insulation Comments: ❑ Ceiling 3:Cathedral Ceiling(no attic),R-30.0 cavity+R-2.0 continuous insulation Comments- Above-Grade Walls: ❑ Wall 1:Wood Frame,16"o.c.,R-19.0 cavity+R-2.2 continuous insulation Comments: ❑Wall 2:Wood Frame,16"o.c.,R-19.0 cavity+R-2.2 continuous insulation Comments: ❑Wall 3:Wood Frame,16"o.c.,R-19.0 cavity+R-2.2 continuous insulation Comments: ❑ Wall 4:Wood Frame,16"o.c.,R-19.0 cavity+R-2.2 continuous insulation Comments: ❑ Wall 5:Wood Frame,16"o.c.,R-19.0 cavity+R-2.2 continuous insulation Comments: ❑ Wall 6:Wood Frame,16"o.c.,R-19.0 cavity+R-2.2 continuous insulation Comments: ❑ Wall 7:Wood Frame,16"o.c.,R-19.0 cavity+R-2.2 continuous insulation Comments, ❑ Wall 8:Wood Frame,16"o.c.,R-19.0 cavity+R-2.2 continuous insulation Comments: ❑ Wall 9:Wood Frame,16"o.c.,R-19.0 cavity+R-2.2 continuous insulation Comments: ❑Wall 10:Wood Frame,16"o.c.,R-19.0 cavity+R-2.2 continuous insulation Comments: ❑ Wall 11:Wood Frame,16"o.c.,R-19.0 cavity+R-2.2 continuous insulation Comments: ❑Wall 12:Wood Frame,16"o.c.,R-19.0 cavity+R-2.2 continuous insulation Comments: ❑Wall 13:Wood Frame,16"o.c.,R-19.0 cavity+R-2.2 continuous insulation Comments: ° ❑ Wall 14:Wood Frame,16"o.c.,R-19.0 cavity+R-2.2 continuous insulation Comments: ❑Wall 15:Wood Frame,16"o.c.,R-19.0 cavity+R-2.2 continuous insulation Comments: ❑ Wall 16:Wood Frame,16"o.c.,R-19.0 cavity+R-2.2 continuous insulation Comments: ❑ Wall 17:Wood Frame,16"o.c.,R-19.0 cavity+R-2.2 continuous insulation Comments: ❑Wall 18:Wood Frame,16"o.c.,R-19.0 cavity+R-2.2 continuous insulation Comments: ❑ Wall 19:Wood Frame,16"o.c.,R-19.0 cavity+R-2.2 continuous insulation Comments: ❑ Wall 20:Wood Frame,16"o.c.,R-19.0 cavity+R-2.2 continuous insulation ENGELKE RESIDENCE Page 3 of 8 l � Comments: ❑ Wall 21:Wood Frame,16"o.c.,R-19.0 cavity+R-2.2 continuous insulation Comments: ❑ Wall 22:Wood Frame, 16"o.c.,R-19.0 cavity+R-2.2 continuous insulation Comments: ❑ Wall 23:Wood Frame, 16"o.c.,R-19.0 cavity+R-2.2 continuous insulation Comments: ❑ Wall 24:Wood Frame,16"o.c.,R-19.0 cavity+R-2.2 continuous insulation Comments: ❑ Wall 25:Wood Frame,16"o.c.,R-19.0 cavity+R-2.2 continuous insulation Comments: ❑ Wall 26:Wood Frame,16"o.c.,R-19.0 cavity+R-2.2 continuous insulation Comments: ❑ Wall 27:Wood Frame, 16"o.c.,R-19.0 cavity+R-2.2 continuous insulation Comments: ❑ Wall 28:Wood Frame,16"o.c.,R-19.0 cavity+R-2.2 continuous insulation Comments: ❑ Wall 29:Wood Frame,16"o.c.,R-19.0 cavity+R-2.2 continuous insulation Comments: Basement Walls: ❑ Basement Wall 1:Solid Concrete or Masonry, 10.8'ht/10.3'bg/2.0'insul,R-13.0 continuous insulation Comments: Exterior insulation must have a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade) insulation and extends at least 6 in.below grade. Windows: ❑ Window 1,Ex2:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: Vanes Frame Type Thermal Break? Yes No Comments: ❑ Window 2,Cx2:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windoZWs without labeled U-factors,describe features: Vanes Frame Type Thermal Break? Yes No a Comments: ❑ Window 3,Jx2:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: Vanes Frame Type Thermal Break? Yes No Comments: ❑ Window 4,T:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: Vanes Frame Type Thermal Break? Yes No Comments: ❑ Window 5,O:Wood Framd:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: Vanes Frame Type Thermal Break? Yes No Comments: ❑ Window 6,Q:Wood Frame:Double Pane with Low-E, U-factor:0.340 For windows without labeled U-factors,describe features: Vanes Frame Type Thermal Break? Yes No Comments: ❑ Window 7:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 8,Ex2:Wood Frame:Double Pane with Low-E,U-factor:0.340 ENGELKE RESIDENCE Page 4 of 8 For windows without labeled U-factors,describe features: Vanes Frame Type Thermal Break? Yes No Comments: ❑ Window 9,K:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 10,L:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 11,K:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 12,N:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 13,N:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑Window 14,F:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: Vanes Frame Type Thermal Break? Yes No Comments: ❑ Window 15,A:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 16,F:Wood Frame:Double Pane with Low-E,U-factor:0.340 , For windows without labeled U-factors,describe features: Vanes Frame Type Thermal Break? Yes No Comments: ❑ Window 17,H:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 18,I:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 19,H:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 20,F:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 21,F:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No ENGELKE RESIDENCE �� Page 5 of 8 t r Comments: ❑ Window 22,G:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 23,H:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 24,M:Wood Frame:Double Pane with Low-E,U-factor:.0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 25,H:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 26,G:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 27,F:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: Vanes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door 1,115:Glass,U-factor:0.280 Comments: ❑ Door 2,118:Glass,U-factor:0.200 Comments: ❑ Door 3,119:Solid,U-factor:0.300 Comments: ❑ Door 4,219:Solid,U-factor:0.300 Comments: ❑ Door 5,127:Glass,U-factor:0.340 Comments: ❑ Door 6,128:Glass,U-factor:0.340 Comments: ❑ Door 7, 129:Glass,U-factor:0.340 Comments: ❑ Door 8,130:Glass,U-factor:0.340 Comments: ❑ Door 9,101:Glass,U-factor:0.340 Comments: ❑ Door 10,102:Glass,U-factor:0.340 Comments: ❑ Door 11,103:Glass,U-factor:0.340 Comments: ❑ Door 12,104:Glass,U-factor:0.340 Comments: Floors: ❑ Floor 1:All-Wood Joist/Truss:Over Unconditioned Space,R-19.0 cavity+R-2.6 continuous insulation Comments: ❑ Floor 2:All-Wood Joist/Truss:Over Outside Air,R-30.0 cavity+R-1.9 continuous insulation ENGELKE RESIDENCE Page 6 of 8 Comments: Air Leakage: ❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. ❑ Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: ❑ Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: ❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment must be identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. ❑ Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: ❑ Supply ducts in unconditioned attics or outside the building must be insulated to R-8. ❑ Return ducts in unconditioned attics or outside the building must be insulated to R-4. ❑ Supply ducts in unconditioned spaces must be insulated to R-8. ❑ Return ducts in unconditioned spaces(except basements)must be insulated to R- ❑ Return ducts in unconditioned spaces(except basements)must be insulated to R-2. Insulation is not required on return ducts in basements. Duct Construction: ❑All joints,seams,and connections must be securely fastened with welds,gaskets,mastics(adhesives), mastic-plus-embedded-fabric,or tapes.Tapes and mastics must be rated UL 181A or UL 181 B. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). ❑ The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ❑ Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: ❑ Separate electric meters are required for each dwelling unit. Fireplaces: ❑ Fireplaces must be installed with tight fitting non-combustible fireplace doors. ❑ Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: ❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: ❑ Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: ❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps require.a time clock. Heating and Cooling Piping Insulation: . ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. ENGELKE RESIDENCE Page 7 of 8 ^J Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Temperature(°F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2.Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(°F) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) ENGELKE RESIDENCE Page 8 of 8 WINDOWS GENERAL Provide window units by ANDERSEN, Inc. as per WINDOW SCHEDULE, FLOOR PLANS and ELEVATIONS. Verify window schedule with Architect prior to placing order. WINDOW FEATURES Wood Storm Watch window units with impact resistant glazing Factory mulled multiple units Low-E 4 insulating glass Simulated divided (interior and exterior) lights with 7/8 glazing bars Divided light without spacers Matching screens in white Factory applied extension jambs of required width Grade 60 coastal hardware package in white Egress function where applicable Standard interior hardware Factory primed on all units WINDOW SCHEDULE ANDERSON STORM WATCH All dimensions shown are single unit frame dimension (h x w) TYPE UNIT SIZE (h x w) A TW 30310 4'0-7/8" X 3'1- 5/8" B TW 3842 4'4-7/8" X 3'9- 5/8" C TW 3046 4'8-7/8" X 3'1- 5/8" D NOT USED E TW 30410 5'0-7/8" X 3'1- 5/8" F 2@ TW 30410 60-7/8" X 6'4" G 3@ TW 30410 60-7/8" X 9'6- 3/8" H TW 38410 60-7/8" X 3'9-5/8" 1 DHP 56410 2@ TW 20410 TWT 5627 7'10-3/16" X 10'2-9/16" J 2@ TW 3056 68-7/8" X 6'4" K TWT 3817 1'9-5/16" X 3'9- 5/8" L DHP 5662 2@ TW 2062 6'4-7/8" X 10'2-9/16" M DHP 5662 2@ TW 2062 TWT 5610 92-3/16" X 10'2-9/16" N FWG 3380 7'11-1/2" X 3'2" O OVL 3020 2'0" X 2'11-15/16" P BSMT 2817 17-1/4" X 27-5/8" Q 2@ CXW145 4'4-13/16" X 6'0" R AN251 1'8-1/2" X 2'4-3/8" Engelke Residence 15 S 2@ TWT 3015 17-5/16" X 63-1/4" T TW 20310 4'0-7/8" X 2'1-5/8" (ALTERNATE#2) (non-impact glazing wood wright series) GENERAL Provide window units by ANDERSEN, Inc. as per WINDOW SCHEDULE, FLOOR PLANS and ELEVATIONS. Verify window schedule with Architect prior to placing order. WINDOW FEATURES Factory mulled multiple units Low-E 4 insulating glass with Simulated divided (interior and exterior) lights with 7/8" glazing bars with spacer bars as shown on ELEVATIONS Matching screens in white Factory applied extension jambs of required width Grade 60 coastal hardware package in white Egress function where applicable Standard interior hardware Factory primed on all units Plywood storm panel WINDOW SCHEDULE All dimensions shown are single unit frame dimension (w x h) TYPE UNIT SIZE (h x w) A WDH 30310E 4'0-7/8" X 3'1- 5/8" B WDH 3842E 4'4-7/8" X 3'9- 5/8" C WDH 3046E 4'8-7/8" X 3'1=5/8" D NOT USED E WDH 30410 5'0-7/8" X 3'1-5/8" F 2@ WDH 30410E 60-7/8" X 3'1-5/8" G 3@ WUDH 30410E-3 60-7/8" X 3'1-5/8" H WDH 38410E 60-7/8" X 3'9-5/8 1 OE-WPW 56410 2@ WDH 2O410 WTR 5627 7'10-5/16" X 9'10-13/16" J 2@ WDH 3056E-2 5'8-7/8" X 3'0-3/8" K WTR 3817(F) 1'9-5/16" X 3'9-5/8" L WPW 5662 2@ WDH 2O62 64-7/8" X 9'10-13/16" M WPW 5662 2@ WDH 2O62 WTR 5627 9'2-5/16 X 9'10-13/16" N FWG 3380 7'11-1/2" X 3'2" O OVL 3020 2'0" X 2'11-15/16" Engelke Residence 16 P BSMT 2817 17-1/4" X 27-5/8" Q 2@ CXW 245 4'4-13/16" X 611-5/8" R AN251 1'8-1/2" X 2'4-3/8" S WTR 3015-2 17-5/16" X 63-3/8" T WDH 2O310 4'0-7/8" X 21-5/8" DOORS GENERAL Provide all doors as shown on PLANS and in SCHEDULE. Handle, store, fit, hang, prepare for finishing and finish as per manufacturers directions. EXTERIOR WOOD DOORS Provide 1-3/4" thick exterior fir doors by SIMPSON MASTERMARK, Inc., sealed and installed per manufacturer's directions. EXTERIOR GLASS DOORS Provide clad exterior doors by ANDERSEN, Inc., with same features as windows and operable as shown. Provide Sliding Screen Doors by ANDERSEN, Inc. For (ALTERNATE#2) (non-impact glazing wood wright series) provide plywood storm panel INTERIOR PAINTED DOORS Provide 1-3/4" thick ENCORE doors by SIMPSON MASTERMARK, Inc. six panel doors, painted, pre-hung with hinges to match hardware finish. Provide 45 min rated door at "Door 119 & 131" SCREEN DOORS Provide sliding screen doors by ANDERSEN, Inc at all ANDERSEN exterior doors. DOOR SCHEDULE # Size (,HxW) Unit Notes B1 2@ 7'0" x 3'0" 6 panel painted 45 min fire rated door B2 Not used B3 Not used 101 7'11-1/2" x 611-1/4" FWH6080 (APLR) ANDERSON STORM - WATCH 102 7'11-1/2" x 5'11-1./4" FWH6080 (APLR) ANDERSON STORM WATCH 103 7'11-1/2" x 611-1/4" FWH6080 (APLR) ANDERSON STORM WATCH 104 7'11-1/2" x 511-1/4" FWH6080 (APLR) ANDERSON STORM WATCH 105 Not used 106 7'0" x 2'10" Simpson 8516 painted Engelke Residence 17 i 107 710" x 2'10" Simpson 8516 pocket hdw painted 108 710" x 2'10" Simpson 8516 pocket hdw painted 109 710" x 2'10" Simpson 8516 painted 110 2@ 7'0" x 1'0" Simpson 8516 painted 111 710" x 2'10" Simpson 8516 painted 112 7'0" x 3'0" Simpson 8516 painted 113 710" x 2'10" Simpson 8516 painted 114 710" x 310" Simpson 8516 painted 115 8'0" x 3'6" Simpson 7512 w/sidelights 2@ 8'0" x 2'0" Simpson 7512 116 710" x 216" Simpson 8516 painted 117 2@ 7'0" x 3'0" Simpson 8516 painted 118 710" x 310" Simpson 7944 119 7'0" x 310" 6 panel insulated painted 45 min fire rated door 120 710" x 310" Simpson 8516 pocket hdw painted 121 2@ TO" x 2'0" Simpson 8516 painted 122 710" x 310" Simpson 8516 painted 123 710" x 210" Simpson 8516 painted 124 2@ 7'0" x 1'10" Simpson 8516 painted 125 2@ 7'0" x 1'10" Simpson 8516 painted 126 TO" x 2'10" Simpson 8516 painted 127 7'11-1/2" x 32" FWG3380 (S) ANDERSON STORM WATCH 128 7'11-1/2" x 5'11-1/4" FWH6080 (APLR) ANDERSON STORM WATCH 129 7'11-1/2" x 5'11-1/4" FW06080 (APLR) ANDERSON STORM WATCH 130 7'11-1/2" x 12'1" FWH3180-FWH6080-FWH3180 (S-APLR-S) ANDERSON STORM WATCH 201 2@ 7'0" x 2'6" Simpson 8516 painted 202 710" x 2'10" Simpson 8516 painted 203 7'0" x 2'10" Simpson 8516 painted 204 710" x 216" Simpson 8516 painted 205 710" x 2'6" Simpson 8516 painted 206 710" x 2'10" Simpson 8516 painted 207 4@ 7'0" x 10" Simpson 8516 painted bifold 208 2@ 7'0" x 1'0" Simpson 8516 painted bifold 209 7'0" x 3'6" Simpson 8516 painted pocket 210 710" x 316" Simpson 8516 painted pocket 211 2@ 7'0" x 1'2" Simpson 8516 painted 212 8'0" x 2'10" Simpson 8516 painted Engelke Residence 18 213 2@ 7'0" x 12" Simpson 8516 painted 214 7'0" x 2'10" Simpson 8516 painted 215 2@ 7'0" x 2'6" Simpson 8516 painted 216 2@ 7'0" x 3'0" Simpson 8516 painted 217 7'0" x 2'10" Simpson 8516 painted 218 710" x 3'0" Simpson 8516 painted 219 710" x 218" Simpson 8516 painted 220 710" x 218" Simpson 8516 painted (ALTERNATE#2) DOOR SCHEDULE (non-impact glazing wood Wright series) provide plywood storm panel # Size (HxW) Unit Notes 101 7'11-1/2" x 5'11-1/4" FWH6080 (APLR) ANDERSON WOOD WRIGHT 102 7'11-1/2" x 611-1/4" FWH6080 (APLR) ANDERSON WOOD WRIGHT 103 7'11-1/2" x 611-1/4" FWH6080 (APLR) ANDERSON WOOD WRIGHT 104 7'11-1/2" x 511-1/4" FWH6080 (APLR) ANDERSON WOOD WRIGHT 127 7'11-1/2" x 3'0-1/8" FWH3180 (AL) ANDERSON WOOD WRIGHT 128 7'11-1/2" x 611-1/4" FWH6080 (APLR) ANDERSON WOOD WRIGHT 129 7'11-1/2" x 5'11-1/4" FW06080 (APLR) ANDERSON WOOD WRIGHT 130 7'11-1/2" x11'11-7/8" FWH3180-FWH6080-FWH3180 (S- APLR-S) ANDERSON WOOD WRIGHT FINISH HARDWARE GENERAL Provide Distressed Antique Nickel hardware by BALDWIN, Inc., on all doors, including: hinges, lock cylinders and keys, latch sets, weatherstripping for exterior doors, and thresholds. Provide passage latches on all openings, "dummy" knobs with magnetic catches at double closet doors, and privacy locks on bedroom and bathroom doors. Provide Distressed Antique Nickel finish at interior of all Bathrooms. Review SCHEDULE with Owner prior to placing order. Engelke Residence 19 TOWN OF SOUTHOLD PROPERTY RECORD CARD OWNER STREET VILLAGE DIST. SUB. LOT Ake ORMER OWNER N E A R. 111 � lleeL-L2enN . 1L al.n echn Azzaye Uj S W TYPE OF BUILDING RES b SEAS. VL. FARM COMM. CB. MICS.: Mkt. Value m4lw L-C). LAND IMP. TOTAL DATE REMARKS r" 3 a 3 0 0 �� ` S d rr�d•`' ,�— a , /7 2,1 �, ze,a "w F ' Z 0 v'a- /� S fib'' ✓ L �4��Sao - t'- 3�oL . // �� e / - �_ a.�.S°cC�. �o_ /�'/' d23 /3 c9. S'--Z��L / �� � //G7�Z-Jew . �:. �' •%�ooe.. 1 ee aall f Igo n eGe,S� ,�J��\'• 'gl-G" �� r' ✓r P XA/ A�'(, AGE BUILDING CONDITION ; NEW NORMAL BELOW ABOVE ` ( s FARM Acre Value Per Value Acre Tillable Y FRONTAGE ON WATER '-` ry r -Woodland FRONTAGE ON ROAD Meadowland DEPTH House Plot BULKHEAD - Total DOCK v fiL . :F: k • WA N .. ■NINE■■■■■■■■■N■■■■■■O-13 ■■ ■■■ .�---� ■■■■■■�®■■Nip.■■■■■■���■■■■■■ *. t ' :W ♦;r � GCS!! e a 4e ■■■■E� ..■EENBEE■■■■■eog■■E:ME IMMIN ■■ Q a ,I _ ■■■EmiMINO■■:■INKRIMINE■■MEN :.� ■ _ . _ _ _ ■■■■■■INL ■■��1'! '■�■■E■■■■■■�■■eft®■ MEN : .. ■■■NEE ■■ E■■E■E■■■E■o!o■NINE■ • ■■■■■■■E■■■ ■��■■■■■■N■■®■E■■ eni§lon ■■■:■:■■■NM=...a�L'z /�i■■■ ■■■■■■ • ii�:::■■E...:::■:■■■■av■.■■■. orc Gov ►wig f = . •.�.�_��� ., -, . . Rooms 1 .. Patio Recreation Room Rooms 2nd Floor �l T � H'• � -mot ,.,�. ! ��t � 9 �_. �/:•:-, -- -- - --- - I ':;-ice ����;�. ��, ' ' R BUILDING WALL FF EL 191 SITE DATA VI6/5/os.63 ' GRADE LINE ELEVATION Iq.2 FT. GRADE LINE ELEVATION 20.5 FT. I SCTM# 1000.98-0544.3 PROPERTY: 5704 Indian Neck Lane GRADE LINE ELEVATION IqZ FT. ' ADRESS Peconic,NY. I' MIN. 2' MAX. 4' MAX. I' MIN. 2' MAX. ! �' ! Q€ ' +may OWNER: SANDRA AND GEORGE ENGELKE I ST.� (,�, 83 CHELSEA ROAD 1/4"/FT. �' 6a GARDEN CITY,NY. 11530 I/8/FT. DI5T. I/g■/FT. TOP OF POOL Ib.'T5 FT. ' PROPOSED � � -ti. � � � SEPTIC BOX LEACHING r , �' SITE: 130,414.28 SQ.FT. =2.9939 ACRES Y TANK POOL BOT OF POOL FT. WATER LINE I �. \- , ZONING: R-80 O IE.+I'IS7 IE. +1621 IE. +15.81' f �r� , '� SURVEYOR: PECONIC SURVEYORS P.C. !• IE.+16.71' IE. +16.0571, 1 I ! �G+ 17.- (t P.O.BOX 909 ?� ' I' ' " IE. +15 8'I GROUND WATER i ! NY. 11971 Z Z 43-O I'7-6 6-O 3 MIN 1230 TRAVELER STREET z W �`� '� ,_ SOUTHOLD, f £fl QR. LICENSE# 49618 0 DATED March 11,2005 SEPTIC PROFILE RESIDENCE (N.T.S.) 22 LOCATION MAP c � I a = ' 0 w T INDIAN NECK ROAD PROPOSED NEW SEPTIC z SY5 � \�� I a % c � 'd a � FOR 5 BEDROOM RESIDENCE AND i / n BEACH SHED, 1500 6AL SEPTIC 'i I 7a s Rd % N 0 ' PROPOSED TANK (ST) WITH (I)4' DIA -' KI I dy Z ~ EXISTING LIG LINVERAROUND WATER LINE DISTRIBUTION BOX(DB),WITH (2)V I ic" WA MAIN I VIA x 8 HIGH LEACHING POOLS I CONNECTED TO OMAIN (LP) WITH FUTURE LOCATION FOR c1 �'� (10 DIAMETER x 5' 1-1161-1 EXP r tea• a�a / Lu UNDER ROAD LEACHING POOLS MXP) DR Y r ` y� `� N boa' w loll I 20-i _s !� m , Z IBB\ ��r -� cD C•�b V I I� DRIVEWAY%j TEST I o• W I ISTIN6 SANITARY + HOLE TO BE a N 67048'40"E ` / ANDONED AND 141.18' Co �� FrILLED IN AIITH $ND ' PROJECT SITE N PORTION OF EXISTING p _ , s ANITARY LINE FROM BY MARK McDONALD oD Z• N c ,t°Dn STRUCTURE TO Be BEACH SHED TO TEST HOLE GEOSCIENCE y a• , �!No RED ;1 // j 1q ' i i RESIDENCE SANITARY OSCALESOUTHOLD, C'=o rr nl i i / / i LINESNEW YORK 11971 w �. I ! i i i TEST HOLE DATA 1127/06 J 6A 11 / 1.0 FT. DARK BROWN LOAM OL w' z N PROP �? it WELL = w m• UNDERISR 18$9+, 4.0 FT. BROWN SILTY SAND SM m i.'N-' WATER. I 0 -^' ' TO B= I PALE BROWN FINE Nc i m ��� \, / �� __ TO MEDIUM SAND SP i 18 17 FT. PROPOSED 16 NO WATER ENCOUNTERED r OSED NEW SEPTIC SYSTEM _� \ 14 WATER LINE FOR 9 BEDROOM RESIDENCE WELL Z AND BEACH SHED, 1500 GAL 16; / -� ( ' 0513 IN) SEPTIC,TANK (ST) WITH 11X DIA I'� — — SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES 60.0 I DISTRIBUTION BOX (DB),WITH RESiDE?�C 1 I PERN9iT FOR APAROVAL OF CCNSTRUCTICN FORA : UT o %i (20 DIA x V HIGH L jW-,HIN6 i / 8�\' III ORTION OF EXIS IN6 c :NS 1 STRUCTURE TO BE SINGLE FAMILY RESIDENCE e46�D POOLS (LP) WITH FUTURE _ 3/14/06 LOCATION FOR(I)b' DIAMETER x 1 �c1 REMOVED ►-60s L :1"=50'-0 W HIGH LEACHING POOLS (EXP) O d �f�►p �10 1 _ 1 SHEET TITLE: �,°3 -; DATE t.S. ' EF. aNN�GHRK I �yy� ' MP-, SCDHS \N� A��aMP � ,,,•`�y, `GN�`OS�A 1 Z66 APPROVED /1 SITE 0 25 p0. y 'v- i MEAN!!: TOTAL 6i.'1E xmptl3m BEOROOM�S S 5 1�Z66 HOG NECK BAY . HOG NECK BAY (RES THREE YEARS FROM DATE OF APPROVAL SHEET NO: —50 Z5 AO Af A( TOTAL SITE PLAN S SCALE: N.T.S. PARTIAL SITE PLAN ENLARGED SCDHS SUBMISSION SCALE: 1"=50'-0" .. nnnl I BUILDING PERMIT EXAMINER CHECKLIST DATE REVIEWED: A_ /0i APPLICANT: DATE SUBMITTED: SCTM#DISTRICT: 1,000, SECTION: ,%BLOCKY" S, LOV14'3 SL DIVISION: C.r ADDRESS: CITY: ZONING DISTRICT:RM CONFORMING?AS BUILDING PERMITS OPEN/EXPIRED: PRE CO: Y OR N-BP -Z/C/0 Z- , INFO BP -Z/C/0 Z- , INFO BP -Z/C/0 Z- , INFO SINGLE & SEPARATE CERTIFICATION-REQUIRED NOTES: LOTS 40,000SF-100-24.Lot recognition.(CREATED before June 30,1983),UNDERSIZED LOTS FROM JAN.1997 100-25.Merger.(A nonconforming at anytime after 7/1/8. REQ. LOT SIZE: ACT. LOT SIZE: 2q8A REQ. LOT COV. ACT. LOT COV. REQ. FRONT PROP. FRONT REQ SIDE ACT. SIDE REQ. REAR PROP. REAR REQ. HEIGHT PROP. HEIGHT . PROJECT DESCRIPTION: IJZ4 6, o, , ESTIMATED PROJECT COST: ARCHITECT/ENGINEER: WATER FRONT? �7 DESCRIPTION: Wax, 61WANEL #' FLOOD ZONE% BULKHEAD?/ DISTANCE? APPROVALS REQUIRED SUFFOLK COUNTY HEALTH DEPT: G r.NO, (BED#): f P DTE: /2a/ 4 PERMIT#: TOWN SEPTIC RECEIPTnYY r N SEPTIC CERTIFICATION: Y or N NEW YORK STATE DEC: PRE-DEC 9/1/75 YES Or NQ- 4j-'� , DTE: 3/ ! 7 4 PERMIT#; SOUTHOLD TOWN TRUSTEES: or NO Asa,. DTE: /g:/ 1. PERMIT#: A' 4 TOWN ZONING BOARD APPROVAL or O DTE: / Y/� PERMIT#: q TOWN PLAN. BOARD o APPROVAL: YES DTE: / / PERMIT#: TOWN HISTORICAL PRE (SPLIA): YES or , O NEW YORK STATE CODE COMPLIANCE (SEE PAGE U YE or NO NOTES: �` `f lA6)4A_0 . A a FEE STRUCTURE: FOUNDATION: SF FIRST FLOOR: SF SECOND FLOOR: ' SF OTHER: 1 W qe) SF INIT OTHER TOTAL TOTAL: / SF FEE FEE FEE 1. ( '31►1 SF)-(300 SF)= al'N SF X$-,/.s =$41Z/ +$ 3s, +$ _ $ AiF� �. (NSF)-( SF)= I�I�°�O SF X $ ��U =$ s!) -- +$ +$ POOL- FINAL TOTAL: $ NEW YORK STATE CODE COMPLIANCE CHECKLIST CLIMATIC/GEOGRAPHIC DESIGN CRITERIA: Ground Snow Load:45 Wind Speed: 120MPH Seismic Design Category:B Weathering: Severe Frost Depth: 36" Termite: M-11 Decay: S-M Design Temp: 11 Ice Shield Underlay:YES Flood Hazards: USE/OCCUPANCY CLASSIFICATION: HEIGHT/FIRE AREA: TYPE OF CONSTRUCTION: DESIGN CRITERIA: ENGINEERED/PRESCRIPTIVE FULL FRAMING DESIGN ELEMENTS: Y/N HEADERS:Y/N WALL STUDS:Y/N GIRDERS: Y/N CEILING JOISTS: Y/N FLOOR JOISTS:Y/N ROOF RAFTERS: Y/N LUMBER SPECIES AND GRADE:Y/N DESIGN LOAD CALCULATIONS: Y/N LIVE: Y/N DEAD: Y/N SNOW:Y/N SEISMIC:Y/N WIND:Y/N WINDOW AND DOOR SCHEDULE: MISSLE TEST REQUIREMENTS: Y/N EGRESS 5.7 S.F.: Y/N LIGHT 8%: Y/N VENT 4%: Y/N NAILING/CONSTRUCTION SCHEDULE: Y/N MEANS OF EGRESS: Y/N PLUMBING RISER DIAGRAM: Y/N LOCATION OF FIRE PROTECTION EQUIPMENT: Y/N TRUSS DESIGN: Y/N CERTIFICATION: Y/N ENERGY CALCS: Y/N TOTAL COMPLIENCE? Y/N (RETURN TO PAGE ONE) UF p�,D N NECK R INDiA UnUTM SURVEY OF PROPERTY \ AT INDIAN NECK TOWN OF SOUTHOLD \ SUFFOLK COUNTY, N, y. \ 1000-98-05-14.3 \ \ SCALE: 1'=50' PII OCTOBER 20, 2004 \ , Dec, 13, 2004 (CERTIFICATIONS) \ Mar. //, 2005 (re vision) ✓UNE 13, 2005 (BofH \ N f°b 23, 2ool- (/.p of 6/ufF7 � N \ O , SµEO \ o , A \ y O 7O \ � 1 1 P , , o , , 0 rn \ a \ 30, % j N O s Z • N - O a Un ` \ I , , N J N o Ln Q � O � O 7[1 Z Z � -o C Z 7 � O l am familiar with the STANDARDS FOR APPROVAL .� AND CONSTRUCTION OF SUBSURFACE SEWAGE Z DISPOSAL SYSTEMS FOR SINGLE FA MIL Y RESIDENCES n and will abide by the condlllons set forth thereln and on the �' permll to construct, v' is N The locations of wells and cesspools shown hereon are from field observations and or from data obtained from others. A¢A�A , UnLJ7 0.8 W 20.4 EXISTING SEPTIC SYSTEf.' T O 6E o � �,)) ,�Rt� _�,.� \/ ••� FILLED IN OR REMOVED 1 ail + �N^�1 \.+'�, o t)nLJn LgITY ap1 E • ' P .fl 0.3 1 µ5E W �0.4 7. CERTIFIED T0+ ENTRUST TITLE AGENCY LLC Title # S - 2410633 SANDRA ENGELKE E cE �3�! o rn. 19 9 > �4 ' S SSE. r 405 141 %6k 1 CA M� b� 0.4' C ®=MONUMENT ' S=PIPE ♦=STAKE 0ooE OF NF�,Y AREA= 2.9939 Acres �o�NT aaEr�G� • TO 77E LINE ANY ALTERATION OR ADDITION TO THIS SURVEY IS A VIULATi^A x OF SECTION 72090E 7HE NEW YORK STATE EDU,- EXCEPT AS PER SEC110N 7209-SUBnI,11,- Irr HEREON ARE VALID FOR T",, SAID MAP OR �^ � E RpAD NECK 101paq , \ SURVEY OF PROP.F;RT Y A T INDIAN NECK \ TOWN OF SO UTHOLD SUFFOLK COUNTY N. Y, \ 1000-98-05-14.3 \ SCALE: 1'=50' OCTOBER 20, 2004 DECEMBER Q, 2004 (CERTIFICATIONS) \ Ppt E MARCH 11, 2005 (REVISION) JUNE Q, 2005 (BOH) FEBRUARY 23, 2006 (TOP OF BLUFF) \ JANUARY 25, 2007 (FOUNDA77ON LOCATION) \ a \N \ Os , V \ , o � j 1 P , , \ v \ , o �o o � , �u l P \ O Ln 711 \ xa N6?�Al 18 s \ cr jN O� Sn Z N d O OY N ' N c7� o N O � J a � N >c O. f to > Z O Z � Z cfl O G n Z f -O O p O 'O Z n N c7P LP N� 0 r � U�'(Y 24 0 Ppt.E see `� 20 e , \� 0 A $i►. 16 R OIle CER 7IFIED T0: �✓ ;;;�Pa ENTRUST TITLE AGENCY LLC TITLE # S-24106JJ SANDRA ENGELKE ' ,�'►`L' O=MONUMENT OF NE$V ®=PIPE 3� co � T.MEr� 0A=STAKE `, AREA=2.9939 ACRES TO TIE LINE ��; �� ��w. y LI `'ive''` 961 ANY ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION P,ECONIC SUR-VEYOR �. . OF SECTION 72090F THE NEW YORK STATE EDUCA77ON LAW. (6X) 755-5020 FA EXCEPT AS PER SECTION 7209-SUBDIVISION 2. ,ALL CER7IFICATIONS P.O. BOX 909 'QFON ARE. VALID FOR THIS MAP AND COPIES THEREOF ONL Y IF `�GgNp 5u '14P OR COPIES BEAR THE IMPRESSED SEAL OF THE SURVEYOR 1230 TRAVELER STRF_F_T 1 ""IA 171FF APPFAR.S HF_R_EON. ELEVA TIONS REFERENCED TO N.G. V.D. N, >� 11071 .� „ ,•'F_. ..�4 ^„•. S.C.D.H.S. REF. , R10-06-0221 USE oAD S�E� ECK R N Ruav` "'A j�DIA� 1 y \ \, SURVEY OF PROPERTY AT INDIAN NECK \ TO WN OF -SO UTHOLD SUFFOLK COUNTY, N. Y. \ ` 1000-98-05-14.3 \ SCALE.- 1!=50' OCTOBER 20, 2004 \ UZI"\ DECEMBER 13, 2004 (CERTIFICATIONS)P MARCH 17, 2005 (REVISION) \, JUNE 13, 2005 (BOH) \ FEBRUARY 23, 2006 (TOP OF BLUFF) JANUARY 25, 2007 (FOUNDA71ON LOCATION) \ JULY 25, 2007 IPA� EASEMENT, MA Y 29, 2008 (FINAL) ) \ s \ o 0\ 7 \ v \ ,\ LIE 1\\ \ \ v A O` `t sn\ \ t \ l .'Un CP P O\ \ 4\ 0 •N�ERE \ �"�\ NC N6�•q8'400 1a V N 1 11 ON l 1 1 0 , 'L \ m �o \ Ln \ � i ;`� is -;1 .�•' - Lw ?�-,1 \ O p• `• �} �� 1-j ci -10 \ Z \ n N� \ j \\ \9� G \ �nuI;{ 10' UpA7 ' F'G'f N FMEN 1�13ti j5—� `ll cn UnILI _ ES ` 57�30.57 \ OSIVEwA / 510NE ' C GB .� 3 C I B UNDER R TANK/ � �� L� 27�? t £ I ��nJuly PROPA U-JPJLIV it t T`� I 206 \ Nqo 3 Cr w o 1 U/Nib 1 569 5 39• m ce s R p C, m Ise pN 24 F010 EP�jIP v� U �4 16 k c z 41 The location of the water line and cesspools shown hereon ore from field observations and or from data obtained from others. 0°4w CER TIFIED TO: TITLE AGENCY LLC ENTRUST TITLE j S--2410633 •i, d o o\� 6ro' C� PlE�v SANDRA ENGELKE ' - ,���L •`� }�,� E=MONUMENT • .a'-'ice F_g � -. 4—STAKE /i- AREA=2.s:39 ACRES TO TIE LIN ANY AL 7ERA 77ON OR ADDi._, ` V TO INNS SURVEY /S A VIOLATION ti : . LTC. N0. 49618 OF SECTION 72090F THE NEW ".QK STATE EDUCA710N LAW. CONIC S YORS, P.C. EXCEPT AS PER SEC77ON 7209-St"Q1V1S1ON 2. ALL CERRFICAriC;/S HEREON ARE VALID FOR THIS MAP AW, c,-!- -c THEREOF ONLY (631) 76:i-5020 FAX (631) 765-1797 P.O. BOX 909 SAID MAP OR COPIES BEAR 7HE IMPRESSED SEAL Of- }i{C SURVE,0R 1230 IRA VELER STREET WHOSE SIGNATURE APPEARS HEREON. `�-E;.E;;n►IONS REFERENCED TO N.G. V.D. SOUTHOLU, N. Y. 11971 92-101 oogA -• --" """ NEW 2" d1a UNDERGROUND REVISED OCCUPANCY OR X N I NATER LINE SITE DATA OCTOBER 25, 2006 USE IS UNLAWFUL INDIAN G F ING � B FA D SCTM # 1000-98-05-14.3 UT CERTIFICATE— — — INDIAN NECK LANE _ S G WITHOUT + UTILITY POLE E 4 PROPERTY: 5704 Indian Neck Lane �- n O/,�, I ADDRESS Peconic, NY. OF OvCUr /`rIC EXISTING UNDERGROUND PRESERVE EXISTING I IN STORf��1 WATER Rl , '-F VAULT FOR WATER SUPPLY WOODS •' '' ••j• . OWNER: SANDRA AND GEORGE ENGELKE 83 CHELSEA ROAD UANT TO SECTION 451 ' FROM PUBLIC WATER MAIN GARDEN CITY, NY. 11530 EXISTING UNDERGROUNDHE T01",IN CODE. I WATER LINE UNDER INDIAN! I NECK LANfE • '� `•• � � A _ SITE: 130,414.28 SQ. FT. = 2.9939 ACRES UNDERARITERS CERTIFICATE "IMMEDIATELY"" I � R � z ENCLOSE POOL TO CODE REQUIRED NEW 2" dla UNDERGROUND AS - ��'` t ZONING: R-80 UPON COMPLETION I 1 ,'° PRESERVE EXISTING WOODS BEFORE"WATER" WATER LINE UNDER SURVEYOR: PECONIC SURVEYORS P.C. APPROVED AS NOTED DRIVEWAY TIED INTO VAULT AT INDIAN NECK LANE P.O. BOX 909 0 1230 TRAVELER STREET 50 — SOUTHOLD, NY. 11971 DATE:/1114B.P. 3� DO NOT PROCEED WITH \ FRAMING UNTIL SURVEY FEE: C> %r BY� \ NOTIFY BUILDING DEPARTMENT AT T LICENSE # 49618 OF FOUNDATION LOCATION 765-1802 8!AM TO 4 PM FOR THE I I HAS BEEN APPROVED. FOLLOWINGS INSPECTIONS: \ NO o .• DATED March 11, 2005 W 1. FOUNDA1fI0N - TWO REQUIRED I � PROPOSED NEW SEPTIC SYSTEM FOR 5 BEDROOM E TH T N STI Z ILI PO 5 BE CONCRETE II � RESIDENCE, 1500 6AL SEPTIC TANK (5T) WITH (I)4' D • FOR POURED CO I I; DIA DISTRIBUTION BOX (DB), WITH (2)8' DIA x 8' \ NOT-IN-CONTRACT LOCATION MAP PLUMBIN(a 2. ROUGH - FRAMING & PLUMBING I HIGH LEACHING POOLS (LP) WITH FUTURE s Y NEW ALL PLUMBING WASTE 3. INSULATIION &WATER LINES NEED - CONSTRUCTION MUST I' RELOCATE EX15T LOCATION FOR (I)8' DIAMETER x 8' HIGH \ - ILI WI _ ''' UTILITY 4. FINAL (C i DRIVEWAY 50 S POLE tea• ij TESTING BEFORE COVERING LEAGHIN6 POOL5 (EXP) �.. A. : , . I ago j o BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE I i THAT IT 15 �`1�' UTI TY • ; REQUIREMENTS OF THE CODES OF NEW LOCATED IN THE g'fIN� YORK STAR I I i RIGHT OF WAY DESIGI \�� Lg>Po HL ORS. I U I �• 22 ; I O N' PROVIDE CONDUIT H-FRAME z s IT 15 LOCATED IN ; ... •' •• . .:�- •� I pl `""�Rd %�%-; % ,,; /; THE RIGHT OF NAY I I -IN—CONTRACT, RELOCATED NOT—IN—G ;i.:; 'Creek / I OVERHEAD WIRES TO »p /i//�j�;,, �, r NEIGHBOR / P L CONSTRUCTION SHALL I ; UNDERG LUMBER CE'RTIFIC�'T/O, + AL EXI5TIN6 I ROUND PROPANE /„/ ON - THE REQUIREMENTS OF TIC ; UTILITY N:DRIV/1=W�, ' LEAD MEET .. L AN1� • I W TANK $ , ; ;�ii/;`% COAITENT E_FO: E EXIST. DIRT UE 5TO.. RFP�G QV'Ei2• ' —I — �a�a �- W YORK STATE.! I POLE �, ' � 1 NEW GENERATOR WITH ALL REQUIRED ra CERTIFICATE p «+ CODES OF NEW I EXP I /°' : p° �.CUPd;P DRIVEWAY TO BE ;. .. � � :�45 HAL �A 1=' SWITCHING FROM �'"'` 4r �r RESURFACED SOLDER USE Ind t.r I - SERVICE TO RESIDENCE LEGTRIG e �i, TER I I - /- /./ AFTER COMPLETE rn r .•.•.... SUPPLY SYSTl.P 'f�G :. ••• .. SUPP CA�L.LOT CERTIFICATION OF CONSTRUCTION OF 15 � 8'>13xt2• � '�• I � ^ � �� ''"" � '' ' EXCEED 2/I ► a• - yy1R�5 LP I 0CF I,,, D. AILfNG & CONNE RESIDENCE i N• _ j. ,(, EXISTING /'i-% LEA: I'I1 , N/O/F I I 8'!3 1.2'. GARAGE TO /a' /;r" ',i', NE IWIC'LIAM 1 ,' '•" � VA TREUREN I I 1 :� BE REMOVED c / / / ' ``/� . 12 I � %; Llittle �econ16. COBBLESTONE CURB • .,/'� . __ _ JI ME', / ,/, 'i�.:?a:r-s/;- �• 20 u. "i/.r.,/r�/�/i:- r NEW PARKING AREA YV/ ,,, COMPLY WI'T I ;; ,/ :;,, ,:;:;` /'r� <..' H ALL CODES OF I / ,.� GOBS EST UNDERGROUND E EG I /' 1 OIL AND BLUE STONE " r/ ? , , �< " L L TR G SERYIGE �� / / C� NEW /. r /r, NEW Y R I _ FROM ,/ O K STATE T E CODES CURB 1 NEW & TOWN UTILITY POLE TO NEW <; �; ;� . N 67 48 40 E I � SURFACE OVER GARA, , � ;/ ,/// , AS REQUIRED AND CONDITIONS ,:; ;���,,; ��; t- EXISTING / O S OF 141.18 I ASPHALT BASE � ti TO NEW HOUSE /� ✓ SOUTHOLD TOWN ZBA Z +fa.s OVERHEAD 1 0 �' P1!`ZKIN� +I WIRES TO BE 1 V N DRY WELLS TO BE ;' �j 1 I. COURT `'',<„` ``? ` RELOCATED NEW 2" DIA UNDERGROUND PROJEOT 5 C SOUTHOLD TON�'N PLANNING BOARD N CC" I ' CONNECTED WITH A 4 ; . ';;;,,:;.; < +IQ.Io , W NATER LINE FROM ROAD DIAMETER PIPE NEON UNDE 0. SOUTHOLD T OWN TRUSTEES I N W 2 % DW �/ OI TANK xi N.Y.S.DEC I ;;. m PRESEI?VE UNDERGROUND _ „ O • �'�'� :' � EXISTING UTILITY POLE ,. ,: EXISTING PROPANE TANK 1�.2+ DW : % + :; +2I.o BY MARK McDONALD vl WOODS Iq2+ ::< ; ''`, +Iq.2 ' +1a2 D ;:;; HOLEGEOSCIENCE Jr 1 EXISTING ACCESSORY ., x8 TEST FLOOD ZONE `�' z ;,, STRUCTURE TO BE -,,:,,.,,, SOUTHOLD r , XIS 'FcT ;�' 2 E T Di REMOVED ;; O SCALE » ,. CO � WITH CHAPTER DRIVEWAY TO BE P�t� �! ;:;:: NEW YORK 11971 - F( ,'_ n - I SURFACED . TES T ST HOLE DATA 1/27106 z , CO) ORNAMENTAL S �ED , AFTER GG�•�1PLETE GOO ��� n> N FENCE w/ GATE o I„ I ISLA CONSTRUCTION OF -a I • N /, --RESIDENCE',; "yµ' RESIDENCE ..-, ALL DRY WELL5 To BE CONNECT EDTO - ` �� 1 .0 FT. DARK BROWN LOAM OL r r� I Z• 5�E= �1�L.Ai�GE=U S I T� EACH OTHER WITH A 4 DIAMETER PIPE „ Z m PLAIT JHT 2�J ; . J c Y r- 18•�X8• L 8•� I 4.0 FT. BROWN SILTY SAND SM r M o DRYWELL FOR POOL 83 I W J. Z 3 ° o NATER BACKWASH DWI o I • V W N PALE BROWN FINE � W z TO MEDIUM SAND SP M00 PRESERVE Oft HIGH CHAIN I W• a N LINK FENCE 2 I EXISTING 1 �, , 20.O 17 FT. = M � NO WATER ENCOUNTERED Q ~' •�-� D 8'OX8.�- I EXIST' NG HOUSE 11-50 EXISTING Cl) N• I r= Co Sx36 18:.25 1 ( TO B)� REMOVED I _ -EF+21 c -14 Imo..-----EXISTING HOUSE TO BE REMOVED D PF-C-K TO DECK TO I I 1 r +I'7.0 +Iq.O " �p ; �j YM I I o EXISTING TREES O TO REMAIN TYP 1 ———�- PROVIDE UNDERGROUND NATER .� +I .2✓5 L — LINE FROM RESIDENCE TO DECK `� X I'1.25+ RAIL L _ AT BULKHEAD WITH H05E BIB z o EXISTING TREES HAY �B�LES TO BE REMOVED ` — —16 I 0 J —14 0 L� ( EXISTING TREES _ —12 G 1 \ ;r NEW UNDERGROUND WATER TO REMAIN TYP — — _ — — — / — '� 4 r LINE TIED INTO VAULT ATg'CPL� 10 BUILDING WALL FF EL IQ.83 a, -4 INDIAN NECK LANE GRADE LINE ELEVATION Iq.2 FT. GRADE LINE ELEVATION 20.5 FT. 'f6 _ _ _ _ -- — — _ GRADE LINE ELEVATION 15.2 FT. P % JECT NO: _ _ 0513 I' MIN. 2' MAX. 4' MAX. I' MIN. 2' MAX. DRAWN BY: �o5w+auw ' — —� -8" 1/4��/FT' I/8"/FT. t1ST . TOP OF POOL 16.75 FT. UT \ �! / �_� i SEPTIC BOX I/S"/FT LEACHING CHECKED BY: NS " POOL \ / TANK IE +16.21' + BOT OF POOL 0.75 FT. DATE: B X IE.+16.'11' IE. +16.03I IE. 15.81 1 September 8, 2006 J� `� �X�gS�NG V�OG IE. +15.87 GROUND WATIER SCALE: 3' MIN 1" =20.-0.r SHEET TITLE: SEPTIC PROFILE RESIDENCE SITE PLAN s 5° C�C�,P G Wpa.� p'Cf-� ,1�2 66G N c �p,N NAG N � M SHEET NO.'. 011ML rr% 1=AN TAN I&- 1 0 M !Jz ,Im - I - 'M N.T. . . SCALE. S G SCALE: 1 20 0 11 . 25 s 50 N- XAO FINAL SET STRUCTURAL REVIEW B"r STEVE MARE5CA, PE WIND-BORNE DEBRIS PROTECTION FOR OPENINGS OT 3 155-0-7 WEST MONTAUK HIC7HWAY, HAMPTON E3A`rS, NY IIcf46 FOR WALL OPEN I NCB PROTECTION OF 120 MPH 5-SECOND WIND GUSTS PHONE 651 '125 a450 ( MAXIMUM MEAN ROOF HEIGHT: 551) SIMPSON L5TA - 20 GAGE RIDGE STRAP - ALL ROOF RAFTERS 2 x 6 TIE ® EACH RAFTER USE/OCCUPANCY • IN VIEW OF STRAP- CLASSIFICATION DESIGN CRITERIA: ICE SHIELD UNDERLAYMENT SINGLE EAM I L`I' RESIDENTIAL SHUTTER ASSEMBLY \ REQUIRED - 24 FROM EDGE DE51 GN IN ACCORDANCE WITH AMERI CAN N.T.S. FOR PANEL SPANS: O < 4'O NODE SPAN CO NSTRUCTION FOREST PRODUCTS WOOD FRAME ONSTRUCTI ON MANUAL FOR I + 2 FAMILY• HOUSE 25/52" APA SPAN-RATED 48/24 SHEATHING GRADE PLYWOOD HEIGHT PRESCRIPTIVE METHOD (OVERLAP AROUND OPENINGS 4") � I ALTERNATE POSITION OF I II ASSEMBLY: �HURRICANE CLIP USE 55 -O MAXIMUM SIMPSON H3 GROUND SNOW LOAD - 45 P517. ATTACHING STRUCTURAL PANEL: FASTEN TO BUILDING w/ FIRST LEVEL - 40 P5F. L.L. O #IOx3" (w/ WASHERS) GALVINIZED OR STAINLESS STEEL LIVING AREAS - 40 P5F. L.L. �0. WOOD SCREW @ 16" O.G. 51MP50N H2 HURRICANE ALTERNATIVE FASTENER FOR SHUTTER TO BUILDING: CLIP NAILED. FROM BEDROOMS 30 PSF. L.L. - RAFTER TO STUD. - WIND SPEED - 120 MPH #10 TEE NUTS ATTACHED TO BLDG. w/ #I0xI-I/2 ( W/ WASHERS) TYPICAL ALL RAFTERS FIRE AREA W MACHINE BOLT 0 12" O.G. 5 - 8d NAILS EACH END RESIDENCE: 6,cf 5-' S.E. SEISMIC DESIGN CATEGORY - 5 Z ✓✓✓��\ WEATHERING SEVERE APA RATE EXTEND TOD TOP YO OTOP O PROVIDE 8d COMMON FROST LINE DEPTH - 56 PLATE. EXTERIOR ED E OF ALL TERMITE - MODERATE TO HEAVY SHEATHING. TYPE OF CONSTRUCTION DECAY - 5L I GHT CONVENTIONAL LIGHT FRAME WOOD ICE SHIELD UNDERLAYMENT REQUIRED - Y'E5 CONSTRUCTION ULTIPLE SECTION A55EMBLY: ir I/4" THICK BOLTS ® 2' Or-, GENERAL NOTES I. ALL WORK MATERIAL, AND EQUIPMENT SHALL BE IN 15. SEWAGE DISPOSAL 5Y5TEM AND FRESH WATER .SUPPLY ACCORDANCE WITH THE NEW YORK STATE UNIFORM SHALL BE DESIGNED AND BUILT IN ACCORDANCE BUILDING CODE, AND THE NEW YORK 5TATE ENERGY WITH THE SUFFOLK COUNTY DEPARTMENT OF HEALTH. CONSERVATION CODE, AND LOCAL AUTHORITIES. 14. THIS STRUCTURE HAS BEEN DESIGNED IN 2. ALL CONCRETE SHALL BE STONE AGGREGATE WITH A ACCORDANCE WITH THE NEW YORK STATE ENERGY PLYWOOD SHEATHING MINIMUM 28 DAY STRENGTH OF 3000 P51 CONSERVATION CODE. TO OVER LAP BOX BEAM - TOP + BOTTOM. 3. ALL LUMBER SHALL BE GRADE STAMPED DOU(SLAS FIR- 15. ENG 1 NEER TO BE NOTIFIED IN WRITING OF ALL L) LARCH STRUCTURAL GRADE #2 OR BETTER. CHANGES PRIOR TO AND DURING CONSTRUCTION. Z DOUBLE TOP 4. PROVIDE DOUBLE HEADERS AND TRIMMERS AT ALL lb. ELECTRICAL AND MECHANICAL COMPONENTS TO BE O SHUTTER ASSEMBLY 2 x 6 @16" O.G. PLATE STAIR AND FLOOR OPENINGS, POSTS AND PARALLEL DESIGNED AND SPECIFIED BY OTHERS. STUDS PARTITIONS, EXCEPT AS NOTED ON DRAWING. l7. ALL STRUCTURAL STEEL TO BE A5TM A56 WITH ONE W N.T.S. FOR PANEL SPANS:4' OR WIDER SPAN 5. BRIDGING TO BE PROVIDED FOR ALL JOISTS AND GOAT EPDXY PAINT. ALL FASTENERS TO BE A5TM Q� FLOOR BEAMS. 5PAC I NG NOT TO EXCEED 5.0 FT. A-525 BOLTS, 5/4" DIAMETER. 23/32" APA SPAN-RATED 48/�4 SHEATHING GRADE PLYWOOD 6. ALL DIMEN51ON5 AND GRADE CONDITIONS TO BE 15. CONTRACTOR SHALL OBTAIN ALL PERMITS AND CONTRA AROUND OPENINGS •4") WRAP + NAIL STRAP VERIFIED BY GONTRGTOR(S) PRIOR TO START OF AND OWNER.INSURANCE NECESSARY TO PROTECT THE ENGINEER 2x4 5TRONG-BAGK5 ® 24" OC% AROUND SILL PLATE 4 - 8d NAILS CONSTRUCTION AND ORDERING OF MATERIALS. THIS AT ANCHOR BOLT FOUNDATION HAS BEEN DESIGNED FOR A 501L Iq. DO NOT BAGKFILL AGAINST FOUNDATION WALLS ASSEMBLY: SIMPSON MST2'1 BEARING CAPACITY OF TWO (2) TSF AND GRADES UNTIL FLOOR SYSTEM INSTALLATION IS COMPLETE. 1 1/2" WIDE - 20 GAGE LE55 THAN 5%. CONTRACTOR SHALL VERIFY THAT 1). PREASSEMBLE PLYWOOD TO 2x4'5: # IOx3" (w/ WASHERS) GALVINIZED OR METAL STRAP c48" OC. THESE CONDITIONS ARE MET. ALL FILL BENEATH 20. PROVIDE CARBON MONOXIDE ALARMS ON EACH LEVEL STAINLESS STEEL WOOD SCREIW a 12" O.G. NAIL SHEATHING TO SILL PLATE CONCRETE 5LA55 TO BE COMPACTED TO q5% AND IN BASEMENT ( IF APPLICABLE ). POSITION NEAR 2). ATTACHING STRUCTURAL PANEL: FASTEN TO BUILDING w/ 6d NAILS o 4" O.C. RELATIVE DENSITY. ENTRY FROM HOUSE TO ATTACHED GARAGE AREA. otf Z . c #IOx3" (w/ WASHERS) GALVANIZED OR STAINLE55 STEEL : WOOD SCREW a 16, O.G. '� � 1. ALL HEADERS 6.0 FT IN LENGTH AND OVER TO BE 21. SMOKE DETECTORS REOUIRED IN EACH BEDROOM AND � Q • �� A ; 2 x 6 51 LL PLATE r- ALTERNATIVE FASTENER FOR :SHUTTER TO BUILDING: 2 - #5 REBAR i.- ON EACH LEVEL OF DWELLING AS REQUIRED BY ,. #10 TEE NUTS ATTACHED TO B1LDG. w/ #I0xI-I/2 ( W/ WASHERS) S. A00 TREATED. SUPPORTED BY DOUBLE UPRIGHTS, c{.O FT AND OVER Y r BY TRIPLE UPRIGHTS. ALL HEADERS TO BE NEW YORK STATE BUILDING CODE. J . Q MACHINE BOLT ® 12" O.G. SEE FOUNDATION DWG. e�gyS. , ' N O O`•' . MINIMUM OF 2-2x8 OR AS SHOWN ON DRAWING. F-0>- X FOR DESIGN. ,. c-5�.. 5/8 x 12 A.B. 948 00. 22. ANY ALTERATION REPAIR ADDITION OR GONVEfRSION TO w/ FENDER WASP IER. ' LV J •H Z w Q r` t =,rti 8. PROVIDE FIRE5TOPPING AT ALL LEVEL AN EXISTING DWELLING REQUIRING A BUILDING PERMITLL WINDOWS - GLAZED OPENING PENETRATIONS NOW REQUIRES THAT ALL SLEEPING ROOMS IN THE ., w .0 ct. PROVIDE FLASHING AT ALL ROOF BREAK5, HOUSE BE UPGRADED WITH HARD WIRED ✓t Q N a o PROTECTION IS REQUIRED FOR ALL GLAZED AREAS. CHIMNEYS SKYLIGHTS EXTERIOR DOORS WINDOWS INTERCONNECTED SMOKE ALARMS. W • N O� =v IN ACCORDANCE WITH LARGE 'MISSILE TEST OF AND DECKS ETC.. 23. THE NYS CODES ALSO APPLY TO ACCESSORY Q F' • 0 coA5TM 1- 1116 AND OF A5TM 1506. CONTRACTOR MAY USE WOOD STRUCTURAL PANELS STRUCTURE DESIGN. IN LIEU OF THE ABOVE MENTIONED WINDOWS. HOLD DOWN -�- SHEAR CONNECTION 10. DO NOT SCALE DRAWINGS. y CO) • � PANELS TO BE PRECUT TO FIT OVER WINDOWS WITH CRITICAL LOAD PATH HARDWARE PROVIDED. FA5TEINER5 TO BE DESIGNED TO II. ARCHITECT NOR ENGINEER IS NOT RESPONSIBLE 24. GARAGE DOORS TO BE RATED FOR 120 MPH. WIIND LOAD ALIGN WITH WINDOW JACK P05')T5 , HEADER + SILL PLATE. SHALL COMPLY W/ Y5BC C PT NHAER #2504.cl.6 FOR THE INSPECTION OR 5UPERV15ION OF PANELS TO BE MAINTAINED ON SITE. THIS CONSTRUCTION PROJECT. FEDERAL, STATE LABEL LOCATIONS ON EACH PANEL. AND LOCAL ZONING AND BUILDING GODS COMPLIANCE SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. T' y5,74 NAILING SCHEDULE FRAMING NOTES TAKEN FROM 2001 EDITION WOOD FRAME CONSTRUCTION MANUAL, AMERICAN FOREST I. ALL FRAMING LUMBER SHALL BE GRADE STAMPED 10. PLYWOOD SHEATHING TO BE NAILED WITH 8 d ® 4" DOUGLA5 FIR-LARCH STRUCTURAL GRADE No. 2 OR - � PAPER ASSOCIATION o.c. EXTERIOR EDGES AND 6 d ® 12" o BETTER. I NTERMED I ATE. "*! ` SIZED FOR COMMON NAILS; CONTACT ARCHITECT FOR BOX; NAIL SIZES �p�OJECLNOt' ` -• h 2. ALL SHEATHING TO BE APA RATED, EXP05URE I, 5/8 MIN. THICKNESS OR AS NOTED. Ii. ALL INTERIOR AND EXTERIOR FINISHES, FLASHING 0513 RAFTER/TOP PLATE 3-Sd (TOE NAILED) AND WATERPROOFING SHALL BE BY ARCHITECT. s; 0 (,100 CEILING J015T/T0P PLATE 3-8d (TOE NAILED) S. ALL SUBFLOORING TO BE APA RATED STURD-I-FLOOR, UT CEILING JO15T/PARALLEL RAFTER 7-16d (FACE NAILED) EXPOSURE I, 3/4" MIN. THICKNESS. ALL EDGE5 OF 12. ALL ROOF RAFTERS SHALL BE ATTACHED TO THE PLATE jQQ CEILING JOIST LAPS OVER PARTITION 1-16d (FACE NAILEID) PLYWOOD TO BE SET ON SOLID BLOCKING. GLUE AND AND STUD WITH GALVANIZED HURRICANE TYPE COLLAR TIE/RAFTER 2-8d (ea. end 1-1/4"" strap) NAIL PLYWOOD SUBFLOOR TO FLOOR JOISTS. CONNECTORS BY "TEGO" OR APPROVED EQUAL. FOR CHECKED BY: NS GABLE ROOFS BLOCKING/RAFTER 2-Sd (TOE NAILED)) TIMBER PILE FOUNDATIONS, PROVIDE HURRICANE o Flo RIM BOARD/RAFTER 2-16d (END NAILED?) 4. ALL HEADERS 6'-O" AND OVER SHALL BE SUPPORTED CLIPS AT ALL PERIMETER JOIST TO GIRDER DATE: TOP PLATE/TOP PLATE 2-Ibd (PAGE NAILED) WITH DOUBLE UPRIGHTS, 9'-D" AND OVER WITH CONNECTIONS. 1 O / 2G / OG j2*0r TOP PLATE AT INTERSECTIONS 4-Ibd (PAGED NAILED) TRIPLE UPRIGHTS. ALL HEADERS SHALL BE A a xT ° MINIMUM OF 2-2X8 OR AS SHOWN ON DRAWING. 13. ALL PRE-ENGINEERED LUMBER SHALL BE GEORGIA do STUD/STUD 2-16d (PAGE NAILED) - y h HEADER/HEADER Ibd (FACE NAILED)' S. SOLID BLOCKING SHALL BE PROVIDED FOR ALL JOISTS PACIFIC GPI SERIES WOOD-I-BEAMS AND LVL AND FLOOR BEAMS AS PER N.Y.5. CODE OR AS NOTED PRODUCTS OR EQUAL. ALL JOISTS GIRDERS AND o o TOP or BOTTOM PLATE/STUD 2-Ibd (END NAILED?) ® 8'-O" O.G. MIN. PROVIDE 2" SPACE FOR AIR � SHEET TITLE: 10 < O <,45 BOTTOM PLATE/FLOOR JOIST 2-16d (FACE NAILED) CIRCULATION IN ROOFS. HEADERS SHALL HAVE BEARING STIFFENERS INSTALLED o JOIST/SILL, TOP PLATE or GIRDER 4-8d (TOE NAILED)' AS PER MANUFACTURERS RECOMMENDATIONS:. WEB BRIDGING/JOIST 2-8d (TOE NAILED)► 6. DOUBLE FRAMING AROUND ALL OPENINGS ( skylights, STIFFENERS SHALL BE REQUIRED AT ALL LOAIP AND STRUCTURAL GABLE ROOFS BLOCKING/JOIST 2-5d (TOE NAILED;) stairs etc. ) OR AS NOTED ON DRAWINGS. BEARING POINTS AT A MINIMUM. A SINGLE 1 5/4" BLOCKING/SILL orTOP PLATE 3-Ibd (TOE NAILED)) LVL RIM JOIST SHALL BE REQUIRED AT FLOOR NOTES & 0 0 "1. DOUBLE UP FRAMING UNDER ALL POSTS AND PARALLEL PERIMETERS. HANDLING, STORAGE AND ERECTION OF 10° o (30 ° to < o L45 LEDGER 5TRIPBEAM 3-16d (FACE NAILED) PARTITIONS OR AS NOTED ON DRAWING ,S. DETAILS - JOIST ON LEDGERBEAM 3-5d (TOE NAILED)' COMPONENTS SHALL BE AS PER MANUFACTURERS PROVIDE 8d COMMON NAILS ® 4' O.C. BAND JOIST/JOIST 3-16d (END NAILED)) 8. ALL FLUSH WOOD CONNECTIONS SHALL BE FASTENED RECOMMENDATIONS. AT HIGH PRESSURE ZONE - 6" O.G. BAND JOIST/SILL or TOP PLATE 2-Ibd (TOE NAILED,9 HIP ROOFS AT INTERIOR PORTIONS OF ROOF - TYP. ) WITH RATED GALVANIZED METAL CONNECTORS BY 14. ALL MULTIPLE LVL PRODUCTS TO HAVE 2 ROWS OF 1/2" DIA. 100< o <,30 ° PLYWOOD ROOF DECKING 8d ®4" O.G. EDGES, ®8" O.G. FIELD "TECO" OR APPROVED EQUAL. GALVANIZED MACHINE BOLTS ® 12" O.G.. SHEET NO: STRIP SHEATHING 8d (ONE/RAFTER) PROVIDE 8d NAILS ® 4" O.G. AT PERIMETER INTERIOR PLYWOOD WALL SHEATHING 8d o4" O.G. EDGE5i, ®8" O.G. FIELD q. NAILING SCHEDULE SHALL BE AS PER THE N.Y.S. PORTIONS OF PANEL5' IN HIGH PRESSURE ZONES. PLYWOOD SUBFLOOR DECKING ad ob" O.G. EDGES?, @12" O.G. FIELD BUILDING CODE AS A MINIMUM. ALL 2X6 STUDS 15. THIS DRAWING IS AN INSTRUMENT PREPARED TO NOTE : a = 4 FT. IN ALL GASES SHALL RECEIVE 5-IOD NAILS AT SILL AND PLATE. FACILITATE CONSTRUCTION AND SHALL NOT BE COMPONENT AND CLADDING PRESSURE ZONES ALL EXTERIOR NAILS SHALL BE GALVANIZED. CONSTRUED AS A CONTRACT BETWEEN BUILDER AND OWNER. ELECTRICAL LEGEND DUPLEX RECEPTACLE OUTLET 220V RECEPTACLE OUTLET QUADRAPLEX RECEPTACLE OUTLET HALF HOT RECEPTACLE OUTLET WATER PROOF RECEPTACLE OUTLET Oom GROUND FAULT INTERRUPTER OUTLET ,'_i■ I81'-10" ,'-I" r(-j HIGH HAT FIXTURE S OD PIPE COLUMN 5GH 40 W/ ro- HIGH HAT FIXTURE LOW VOLTAGE 4ox4oxl6 GONG FTG W,d DIRECTIONAL HIGH HAT 16' 18' 28' 52' SURFACE MOUNTED CEILING FIXTURE V SURFACE MOUNTED WALL FIXTURE • I - - - - - - - - - - - SURFACE MOUNTED SPOT LIGHT O •," I I w :.'. •,. .i.a r• w .;wif.4V. 7a� ..*.••.•• . I ( y` I SWITCH B'-II" I I DOOR 5WI GH i I 5 I O I I m 1 I REIINFORCED 5WITGH DIMMER tt 1 } I 16 c o -1 1 :• I 1 I GOMIGRETE GRADE PH TELEPHONE: W 1 wl ff N IRS F o GONG PIERS 18' VIA L- - - I I 1 •• L - - - - - _j 1 DOWN TO BEM SEE DETAIL ELECTRICAL SUPPLY TELEVI510 MATCH LINE _ I :�••••r•... I •.•��% «. • f •=.r ••%' I MATCH LINE urmisTURBED su>3 5/211 / LINE FROM POLE 5/D SMOKE DE GTOR - ; I 3 LVL I - - -I ; '� - - - - SEE PAGE b GCE, 5RADE MIN w. ;.....;. . SEE PA&E b 4' I I I 5URFAGE MOUNTED CEILING FAN SURFACE MOUNTED FLORESCENT FIXTURE CONTIHANDRAILNU US I in UNDER G INET MOUNTED FLORESCENT 'FIXTURE ' • I TO lot FLR y� i 1 / I I I I T SURFACE MOUNTED LIGHTING TRACK • 1 m 1 PEll PROVIDE CONCRETE BLOCKS I I / EXTERIOR L MOUNTED FLOOD LIGHT (8xl6) STARTING AT TOP OF I I I I X EXHAUST F N C I S LVL - ,uP„ I �tNS TO BOTTOM OF 12 I S-10 I E BEAM •� I J•+ a a • .a r :,•t, ,a •S� sr ;ti.. .,�a J•••• BASEMENT I I - I '. I / - �1I� ( : I 1 .. I BASEMENT METAL I i L WASTE 1 _T I �' 1 \ I I . I LINE our 1• 1 1 ? I I 141 :. . I I WINDOW NULLS TYPICAL I :. 7 I ' I 1 • — — —— — — — - { I LInsHrs I i.• I / '�- I I/ T®I�60 J 1 . 4 4 I ` I 1 •mot. , :• .j. ., I — — — GOT OTED TO 5 8' II'-I I• T'-I" q� 1 I — •••— — —— — —' LIGHT A► _• 41 4' BASEMENT METAL 00-0 • I - FIRST F «. WINDOW YELLS .•_ / 1 I I ' 1 —�— I / TYPICAL 10' I I 1 - - - - - I I I sz — 1 - - - - - - - - Aql L_ - - - - --) " ~ - - - - - - I - - - - � I _ WIOx30 1 I 's `• I- - - - - -j y ~~ L - - - - - - - -- - - — - - - -- - WIOx30 '.• — — — — — ♦ • i.+ may. • a•' J• ♦ •:•••• . I •.. a r 1 •♦ v w, ..r ,�,• r' I / - - - - - - J L - - - - - - J a / II - - - - - - - - — t — — — — — ' - - - `� :. ELEGTRIG•PANEL. L � u II I ' I t • � � � � N� GOLIUMN 4" MIA PIPE ;A 40 I''�'�'os� �o I T II i WATER SUPPLY LINE I ' PROVIDE CONCRETE BLOCKS `• . 1 t(1 �I m �� 6 GCJ"c' J1 (8x16) 5'iTARTINis AT TOP OF I : I \ X -� ® m IL TO II CCF .o POST I ' FOOTIN67 TO UNDER SIDE OF �- — GRADE BEAM — — — — n \ " - - II ® ABOVE �._ '• • . , . \ - n PORCELAIN LIGHTr 2 LVL I I - ♦0 Lt_r- - - \ •\\ I in / I FIXTURES (TYP) I O I I / I • . I V IOXIB IREINFORGED I I \ ..� \\ i ® m II CONDUIT LINE m i = i a CONGFQETE GRADE - I I \'• _ BEAM It I \ ' „ II \ �►. 24YI" :2,'-�2 VIF 3, N r / I 13-6 � 1 I I jl, F — - -I 1 mn o — — 1 : • 10• I I I II 23 I I 4'-I" \ _ WI2x,9 - / ( I 11 _ WI2x40 WI2x40 ,, WI2x,9 3DTTP�"- — �J I I I i COLUMN SGH I I I>'E I I 06 Z. I . I ' PROVIWE CONCRETE I BASEMENT 1 W/4ox4oxl6 50H 40 W/ — J L — — GONG FTG II L — — 4ox4oxl6 BLOCK'S (8x16) STARTING I I 10'-'�2" I : ( n � / � � y Q• M AT -lOP1�1 0>O I&T I =• I 4 GONG. SLAB I ` mI _ _ II CONG FTG SLAB I I RE I NI=ORGED w/ bxb , 4" OD PIPE 4-�'z v�ATER TER I I ° o / .•��� •. . :.�:�• \ to/ro W.W.M. PROVIDE COLUMN s L — PORGEI.r'�1N I I v °a } / \ \ 51 40 PV / I ANI hL/STORAGE AREA LIGHT FIXTURES I . . I W ..�• U 6 M — CONTROL GUTS AT (rrn) Z I/ ♦ •- - - - - - \ \ \ i 4ox4oxl6 \ I 1 \ I I = a z •n {, / \''. \ 20 INTERVALS. (TYP.) I GONG FTG ; I . �, .�; J II Lu cm TING EQUIPMENT I_- \ 1 • ! I w' in 4" OD PIPE 1 I •��,ti�•"�•'E':. I II\ POST I I v / +� / \•• ►- COLUMN ABOVE I I 2�- Q �-• 4ox4o�xi6 / ;;?•'3 �<. \ — PROVIDE EJECTOR N cn• GONG FTG I ��i+�' 3".'• • \ I TANK AND PUMP TIED FROM BEACH HOUSE I I �/ �>, I I / I I + t ? {';: •`'•;.' \\ OIL WASTE LINE AND To I t 1 r��`rt \` •• 411 SLAB ON �• I I ' !� ,t:,. MAINREIDENill I I 1A GTE LINE RADE ABOVE t L- - - - - - - - - - - - - _- - - - - - - `D wI0x30 / I I _ _ '"� } .:. ;�, — - - - — — — — — — — — — — — — — — —— — — — — — — — w I • ♦ g• I ` •.• •' ••y.r ,� •r • ••., t .•r.,•• ""I L { � s; �..M•'!R•�,. , • •7•�.. •ar,. • •'»•rr '.•♦will • 4 t �.�. •,.".•, e .?� I I I t _ I (7 car 3 .'77 .. ,. B I I 1 •. 1 • , I / T 2 to PROVIDE CONCRETE BLOT I I WASTE LINE .� I I \ 0 1 : I (8xl6) STARTING AT TOP OF FROM 11 Q I 151-20 3'-2" t I FOOTING TO UNDER SIDE of HOUSE •• \ GRADE BEAM \ / • : j PROVIDE GoNGRETE BLOCKS I I IOXIB REINFORCED \ I I (8x16) STARTING AT TOP OF 1 I ' I I f < O y f /,.r/ FOOTING TO UNDER SIDE OF 1 ' I I • I CONCRETE GRADE BEAM I I COW., PIERS 16" VIA lu L \ '�. \\ f I GRADE BEAM 1 I I I DOWN To f \ \� , _.• f I I I UNDISTURBED " k" \ -- ------------- --- I I -------------- ---- SUBGRADE 36 A ( \\ - - - - - - - - - -J , % / — -------- --- --- 1- - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - � -------------- ---- �• rho .•.;• .r+r / BELOW GRADE MIN �` f PROJECT NO: •.�• �• !. f :♦ . • Isr` Z• YI :• . :.• ,• ,• r.ro 1A :. '.i . . J" 0513 — — — — — — — — — — — — — — — — — - - - - -- - - - - - - — — — — — — — — (//r1DRAWN BY: GONG PIERS 18 IOXIB REINF C" ` �. VIA DOWN TO CONCRETE GRADE BEAM TICS 51 UNDISTURBED 56' 14'-10" r-6' f ' "' , . BELOW GRADE MIN PROVIDE CONCRETE I I 8" q i' ,. r`: � ATE: sLl (8x16) STARTING I I 10 "�' f 9/6/06 I I AT TOP OF FOOTING TO I I NOTES: ! I I EOM of CONCRETE I I I (2) 2x8 MIN HDR 0, 1/4" = 1' - 0" i I 11 ��" II'-2' T'�• 11 I I Clow, PIERS 18" DIA APB =3 ANTHONY POWER BEAM SHEET TITLE: I I I I Dom To LVL= I /4x I I /8 M I CROLAM UNDISTURBEV -------- ------, SUBF'RAM,56' ------ -------- BELAW GRADE MIN .. ., .. , ------- ----- ------ ---- - BASEMENT 28' g2' PLAN IOXIB REINFORCED CONCRETE GRADE BEAM SEE IAE DETAIL 05 SHEET 021 '13 TYPICAL LAN- SCALE: 1/4" = 1' -0" 2" THK STONE PAYERS ON 4" THK GONG SLAB NV 19(o 6X6 WWM TYPICAL 12"x 72"x2" THK STONE GARAGE f Iq WIDE WEATHER STRIPPING AT ALL EDGING ON GONG SLAB ESS DOORS TO UNHEATED SPACES HOR FIRE RATED WALL 16, IGAL I, V ASSEMBLY 6/V2' 7'-2" 6y2r 18, 8 52' PROVIDE ONE LAYER 5/ $$ TYPE "X" GYP BD ON GARAGE S ' IDE O AND ONE LAYER " TYPE ' 8' 5' 8� 2 5 "X" 5 al' '-5" al" 8' 2" ' 8' Ial' GYP B1:7 ON OPPOSITE SIDE 4' 4' 4' 4'-BY2 5 '-6' 51-6` 4V2" .1'42r 4V2" T'-`02` 6y2a ,IT I TO E 4'-II" 2'-`y2" 4'-I" 5''5Y2' Z I MATCH LINE MATCH LINE 5EE PAGE 5a FACE (5 _ FROSTPROO D x o • a BIB �� (t) 7 AG 6)/2a / TI © G � F BIB O O a C IIl x8 I upset above 12 ry = (5)2x10 ; HDR t(I) LVL, X BEAM E w 1 e s © -? NT • • 2 ST PAVERS LOWER HEI OF O 4" THK NG SLAB '?+ CEILING IN MASTER, l ry t f. W/1% 6X6 TYPICAL BATH SHO TO 5 f g a G o i u „ '1 IL ) O = SLOPE END % \ " T' _ BASEMENT WI OW FROSTPROOF OF LVL \ 2 B T J :' r + WI OW YELLS �•{A CONTINUOUS' WELLS TYPICAL,, HOSE BIB tf- FLUSH W/ TOP ovlQ 4 IGAL O '�� Ib m 11s STAIRS TO TO to LR • f�#> OF RAFTER o I T 1 a ° _ in an 1 a BASEMENT _ CC x 2 I I f e stone Header Header j bench SH 3 Imo. 'tV n /PwVI ..r,�.� IN CIL 5 P ALO �� I .. POST ABOVE WOOD FL HOSE BIB TO ;,�� D m IDEAC L % .,,,. ;j� T IRS 2nd FLR 2 FLUSH —2 �- tT c n K- ..„ D p �.. PF1s /20 railing I o , � 1 � O 2 M THK. STONE PAVERS ON - _ _ © 1 19 3 I I I I ( BAR AREA I I VIF " t IO' I I g-'�2' 2` n 5 1 LINEN WOOD FL = 4 THIG GONG SLAB YV do 1 I I — ~® reP m V f '„ W 6X6 MM TYPICAL . \ % m / ° % m - 10� 1os ' — II_ � _ _ _ \ O O \/ \ \< SVaXIf�IAPB xtt APB '-ajc 110 a g /, .. •_ (5)2X4 POST D x8-R %%%< / %%' .W $ :%y. . — cased m Dog W • ; P HALL/ LUSH 4'-6. II " 8" SO CASED COLUMN " I '1-6 YV(4)2xb 'TYP 'I-6 BEARING (2) 2x10 � L � L — I PROVIDE BRASS 106 23 m 4'-I" -I 111 11 I .r ( \ ry otS Z• p LIVIN6 AREA \ CATHEDRAL-CEILING GAP. 2' 5' 5'-5" 8'�" 4 T p co Q' i I I 1 5 :� (PAINTED) I I T i l l I I wwOD " " YIF ' r J Y J e ) JT�Y 1 ~® GABt • Z O LLI J __••�' NETRY — — _ _ WOOD FL '� BUILT-IN-PLACE p a z z0 " 1 � ,; • ' — \ -1 \ 1 I I I �3..!- 1�STER DETAIL (NIG) X c� W• g 12 x'f2 ,x2 THK STONE u- �. •. F EDGING cON CONO SLAB STRUCTURE ABOVE 5EE r��+ BEDROOM (5)2X4 POST W TH 42 � W• a N = TALLOPER OOIO WALLS AT I I I I I I I I SECOND FLOOR PLAN ..• 19 � " m � ggE 19 2 `Z l�l \ PLUMB 4 WOOD FL POST ABOVE r 15-*2 AR � STARTING A N�7— I � , ' ,�� TRAAY��ING O Q 1•.-. � ;g SHI LE SIDING 1zs \ \ LEVEL TO G t \ L�— —I( () V I I 17 1 - I I 12" HIGH �`- C� 6' 5'-10" 2'-10" 2'-`�2' 3' 4'-8" a �� 9 . / LS IN — val- al— I RAIS> • `�'a F I r: Q I I I ° I I l I I •rs� .:"�.f HSTONE EARTH , 3 TO A 1 a g w f 2" THK TO PA ON I I I I I •..•.. �: \ _ 4" THK o —I —J I— I I— — — — — - r�'rs; , y►. -- - — X bXb IGAL %Y:;, .�, — "• t ,,,. (3) IIYa LVL \ (3) ih/8 LVL / 4 B I I I 18 I I x8 RR I to HOSE BIB 11 .• • G D PO G -/ • •• n Bib 2 J :r9 K I - -- - PRO\(ID?E 5/5x5° STEEL \ su OOM l� a 4' -I`�2" 5'-"i" 5'-7' g'-I�" 4' x G g1-2■ PROVIDE 5 IN CONCRETE T $ PL ATI£ 12" EACH LEG �+ t2�"612 ` _ 5T \�Y+e� IN�O H a� _ P RG — f--1 I j W/(2)5/b` MB EACH SIDE 8 \ \ i 1 1 2 FOR DOWN OUT TO DRAIN TO i t x TYPIG%AL EACH WALL CORNER OF SUNROOM •• -- 2x12 I - ( ( 2" THK STONE PAVERS ON 4" THK PROJECT NO: ®TOP OF CANTED WALL. 3 2x8 ed eb�ammove (3)) x10 —�- -�-- TYPICAL 0513 5EE SECTION "B" �`'_:. ,•> _I a 3 a L� 6/4" x4" MAKOGANY SCR15::T1 DRAWN BY: FRAMES, ATTACHED 12"x'12'x2` THK STONE I p �( ( T�. . ECKED SECUREL T06GLE5�.PR10YIDE BRONZE EDGING ON GONG SLAB NGRN I x8 RR O�rE D 2x8 I A " � 1 BY: SCREENING TYPICAL 5P �o — -- -�}TH I 10 8 r DATE: IN D p 2 STO? EE�I'A ON p dX 4" TtNG Cow; 5 6 -bno x Im6IN6 ON COW-,SLAB a NOTES: Y ' +, /A� 9/6/06 I I ,ylry &A WWM1 TYPIG x x m � 1 1'-6" 13' i'-b" -��- (2) 2x8 MIN HDR . m I APB = ANTHONY PiOWER BEAM 1/4" = 11 . 019 1 I I' 16, LVL= Ig/4xllle MIGR�OLAM SHEET TITLE: 2" THK STONE PAVERS ON I ( I 4' THK �CAL19(o _ XI e � FIRST VARIES SEE FOUNDATION PLAN AND BUILDING SECTION 51� ' FLOOR 1 i 8. PLAN 12" VIA 5000* RATED PREFAB COLUMN WITH %w E 12'x'12"x2" THK STONE VIA SIMPSON 12 W&ING ON GONG SLAB HOLLOW COLUMN SHEET NO: AI R%AO%RT 1" L 0(mim" mmP L 8'4HOLD-DOWN I I" TYPICAL 11" SCALE: 1/4" = 1' .0" '11-6" IW-2" '25' 52' 14' 14' MATCH LINE _ I I _ MATCH LINE SEE PAGE 6 SEE PAGE 6 42• I " $ 5' 15'—W2" by2" U.1 4' 4' (4)2Xb POST 5' 8' 4'-5" 5' 4'-5" I C I i 41 4' 2'-6" 2'-6" 12 I n 2XIO I I I n RR — pt I TINN&LNG 4I AT STAIR 3 LINE OF !! ` SEE SW N I-I_ ' t . 2 R rt a FIRST I i II ��F � BPJ..OW LINE OF FIRST 1 WOOD FL 1 FLOOR BELOW STAIRSTO - - - - - - - - - - m � I let LR I — _ _ J LG_ coLLARTIEABOVE - - - - - - DN _ - - - J _ - - - - - - \ n _- - - - — — - - — - - - --- - -� 1 - n (4)2x10 CASED = _ SEE DETAIL#5 GONTINUOIJr ' - (4)2X4 POST % to I SHT20 �) HANDRAIL TO % ''% ` 2 2x8 lot FLR = I I r / P .. ... t( /e.a✓;•✓ r - - - - - - — - - - - - — change In ce ling itch I I I I ANGLES W/ (3) s/4" I I - 14 APB i%% I n1 MB EA LEG, n� %% x gambrel pur(� \ ra � f A 2' « ai,: „ U21 I I I. (�EXTERIOR ' 215 V 1 209 > WALL BELOW Q O I I \ \ (?� x i�cs/e S�T1. I iv I 0- '�2' : .. / %.. m IN, ANGLES « j �- oc Ll MID EA LEG, 5-6 5-8 ; �i -.�;.,, — — — — — — — — — — BED N ,. (4)2X4 POST =► \ II L1.Att TIE ABOVE railing �. ROOM #4 WOOD FL —_ f I`^+I (4)2x10 vr� -� I SEE DETA 5 '� / / I I ' r -1 207 0 Z 23 u� VIF 3'-6" SHT#20 \ \ / % 8" SO CASED I �—52 50 AGGE55 " HALL 03 v 1 O 4V2 HALL I " I HATCH TO ATTIC i WOOD FL I I N « 214 WOOD FL to > I I 8 SQ CASED \ ' '� / / COLUMN W/ 1 I > q-�2 2 O �2" 2" COLUMN W/ \ \ / / (4)2xb TYP I L-- ABOVE I N CENTER OF &ABLE _ 2x12 ridge becm _--� - I I (4)2x6 TYP \ \ y�,/��ridgge beam or _ I I - I 2xl2 ridge boom I W I Ail11 - f - - - j+ 2xlo PL SET /> Tdge Po _�— �y 52" SQ ACCESS I I ON MAIN ROOF / \ \ 2X10 PL SET I I n BED i I BED I a- r r I / / \ �- 202 I \ r )'RAY CEILING, ABOVE HATCH TO ATTIC 2(7 I PROVIDE FRAMING, A5 ABOVE i O � � I 1 / '•/ � \ ON MAIN ROOF I I \ � ROOM #I , I ROOM #2 I REQUIRED� BUILDING, - - - - � � i I /. I �- - - - - - - - - - - � I WOOD FL O IONS AND DETAILS I m `� / y \ \ I I 2'-�2" WOOD L I TRAY CEILING, ABOVE - J x II c = \ \ I PROVIDE FRAMING, AS BED ( LEASED r d od�ME ABOVE I - - - - - TRAY CEILILNG,- I I x - - N II 3 - _ - -\ - - J �- - - ABOVE PROI/IDE REQUIRED SEE BUILDING, N .a 11 11 I ROOM #3 1 - °_� � 0� � - —� - r - FRAMING A5 I SECTION5 AND DETAILS cxY SEE DETAILS \. I I p REQUIRED x I 21s - n /• / SHT#20 \ \ I it N - BUILDING, T10NS I �tS Z WOOD FL I v / % \ \ -� AND DETAILS \ SET RR ON / ;+j - - - - - - - - - - - - - � `` m I / \ II 201 - - - -� �. TOP OF \I O1 TURRET /! ..F II ABOVE 14 APB \� en to I a ;r II r�,�14 APB \ A4 APB OPEN TO gambrel purltn \ LIVING AREA i` Gre?"pur n , ga"m��r�'pu'r(ln \ w o a M . I � — — — — —� below �'� - II— - - - - - - - -n - - - - - - \ - - - - - - - - - - - - - - - W I I 5,� J e 2x10 I (?a �4x� /a " STONE VENEER _` f f ; Y ' W ui ANGLE5 NV(5) �/4 CHIMNEY I la +�q �Y+�� �+ it MB EA LEG / -. PROVIDE CEDA f W' a N = M SHINGLE SIDING 2x8 GJ cASED COLLAR TIE ABOVE - - - - _ _ _ _ _ _ _ E: a x ON ALL WALLS IN �� 2)2x8 - _ - - - - - _ - - I - - (2)2x8 ��v I,�C ��� — � �- —(4)2xlo EASED...5EE— — — -1 r- — �!; TOWER - - - - - - - - f I ( DETAIL#5 5HT#20 I 1 B TIMBER I III I III I LINE OF FIRST FRAME I 2x10 RR a0 2x10 RR ABOVE I FLOOR BELOW I I� I ° ��J`'+ ryk CASED ORNAMENTAL m n NOTES: & I I I COLUMNS ON SLOPED CIE-LYING,o� INTERIOR I ILL ' (2) 2x8 MIN HDR , ; _ APB = ANTHONY POWER BEAM 11 4- HH �� 1111 11--�. i I I I LVL= I9/4.x11'/8 MIGROLAM (�)2xlo awl! 4 2X6 POST X6 POST _ "" sy+y i �— I A PROJECT NO: 10 0513 000C DRAWN BY: TCS equal equal E ED BY: NS DATE: 4' 4' September 8, 2006 4' 14' 14' 4'-5" 2'--*2« 2l-DY2" 8' 9l-W2« A 1/4«1 = I - 0«. Ilk ve Ify varies see building section SHEET TITLE: varies see foundation plan and building section I61-5" �8' 1'?'-'�2" 14' SECOND FLOOR PLAN " E"=- to P.0 RD F L 0 R P NL A I'M SCALE: 1/4" = 1' -0" A - STANDINS SEAM LEAD W COATED COPPER ROOF ON MA�TG�� LINE _ _ MATCH LINE 5/4' I�I-'�'MOV VMKM ON 5EE P��GE 6 ALUM. 5EE PAGE b &UTTER M rr) RAFTERS BELOW 15 MIT [7 F �Tl 77- 11 ITFM d19MR1 I E DOWN F I DOWN SPOUT TOF SPOUT DOWN DOWN I SPOUT 2S SPOUT DOWN /6c% F' 12 SPOUT u i o I = I = Q DOWN SPOUT 81 =I T I N JAW 7 L.A114 ON DOWN DOWN DOWN SPOUT SPOUT SPOUT &U ALUM. TTER (`T ALUM. &UTTER M) --e7- 77777 00, 0 AlI =I G I 121-j_ = 2 ?x C \, x /. �X. • / PtIlli y BUILD ROOF ON TOPOF FOOF MELON / X X `K. Tx ,N, xx BUILD ON OPQr- ROOF Mr-1 OVJ —` \ k'l Y K h Y" KID&E VENT Vr-NTo� Z. x '1 7 r co Q• CC m':y;:;l J G• G X / PROVIDE CRICKET - -ol POSITIVE ROOF �' o ol • _ Z LL UL • �1 -2401 IDE W aN � � DOWN TYPICAL AT SPOUT L ;yWALLE Q F-• - - - ---- — -nfFICAL N N• EJ PRO`,AM HURRICANE CLIPS AT ALL RAFTER TO PLATE CONNECTIONS MQXRZI Col-INNN _ =I 1 _ Ioo oo IAB D ,- ru. fi 81 PT I T i N. ALUM. &UTTER (TYP) DOWN .� SPOUT r �Iw PROJECT N o I = I o 0513 ALUM. &UTTER (TYP) ALUM. &UTTER (TYP) DRAWN BY: ALUM. &UTTER (TYP) MT DOWN SEE ROOF PLAN FOR MORE TICS INFO ON ROOF PITCHES IN E E THIS AREA DOWN Dom STANDING SEAM LEAD NS STANDING SEAM LEAD COATED COPPER ROOF SPOUT 4 WD:12 ROOF COATED COPPER ROOF ON SPOUT S/4' PLYWOOD DEGKIN ON ATE: ON 5/4' PLYWOOD DECKING ON RAFTERS BELOW 10 RAFTERS BELOW September 8, 2006 PROVIDE HURRICANE CLIPE AT ALL A RAFTER TO PLATE CONNECTIONSInx 0 F L A No = 1' -0" SHEET TITLE: SCALE: 1/4" ROOF AUM• &MM GYP) PLAN E STANDING SEAM LEAD COATED COPPER ROOF ON 13 8/4' PLYWOOD DEGKINS ON RAFTERS BELOW 4' Ib' 4' 24' 411 10'-1" 6yZ" � - .,,, •%,.ir•;r.r r'- is ,■� � .. ., .. .. _ (2) 2X8 I ■ CONCRETE APRON b' THK WITH 6X6 10/10 REBAR 12 IZ i In OVERHEAD GARAGE O I I O DOOR M 2xa RR I 2X5 P.R. ® Ib ® Ib I yZ" EXPANSION JOIMT m 3 1/2' DIA SGH 40 1/2' ION W/FILLER 4 SEALANT STEEL. GOL LHK O I JO TYP (Tyr) I FILIED WITH GONG O n I ■n .n TYP. IN GARAGEUL ` (3)2x8 I (3)2xb r .n — — — — -- r •� 2x10 GT — L -1 O uj .n Z ril v mIn Z. 2x10 FJ ® Ib" L/ D N 2xi0 2x10 x 0 p SEE UL FIRE RE51 TANGE DIRECTORY 2000 OX" � ry n nr DESIGN NO L544 tNRESTRAINED ASSEMBLY RATING � 12 rt go ridge �m - 12 OVERHEAD 6ARASE ONE HR FOR DETAILED INFORMATION o 2x6 R �- DOOR 9/4 PLYWD 6UBF GLUED TJI FLR JTS,PROVIDE r V TWO LAYERS C GYP BD 5GRENED TO m n ® Ib / / I I I ♦��+ ♦ ��J `n I RESILIENT GH Oi"x2142" 25 GAUGE GALV STL) m �+ �+ O 6 n ■ SGREY0D TO TJI LR JTS In / (3)2x8 _ (3)2x8 _ - - UNFINISHED n L J I - TYy,�lo ( I &ARA&E I �� HOUR,FIREASSEMBLND WALL SUBFI.00R 4" THK CONCRETE SLAB PROVIDE ONE LAYER �" TYPE I WITH 6X6 IOA777AT 'X" GYP 50 ON GARA6E SIDE NO FINISHES OR I NE LAYER. r L 2x10 P.R. O I INSULATION I OVERHEAD GARAGE ��B17 ON OPPOSITE 510E 6 x 2x10 RR DOOR o ri ® I6 I 4/2 '1'-E►�' mI � PROVIDE WEA I - STRIPPING AT 'n 219 I ACCESS TO ■ ,._ O220 ( UNHEATED SP E5 I TYPICAL d1 5-4" I ■n 218 m ON ( T I GL I T I IRS T I jn 119 rtt G • Z T H LINE _ (2) 2x8 I MATCH LINE _ _ MATCH LINE L,- e �c ,.y�, O EE PAGE 04 I s s SEE PA�CGE 04 6Y2" 6yz SEE PA�CGE 03 V 6Y2" 6y2' W I4' '/'-Z" - 4'-1" 4' a 8'-7" 3'-5• Ib' 12' 4'- " S'-8" 24' 4' DOWN DOWNR ` S� FLf"'k P"t LA NI w u r 8" 8" SPOUT SCALE: 1/4" = 1' -0" II'-4" � . �t f--•V_.__Mom•--.f:1•. ta. .•.�:• •,M----I••-- •r � Z• SCALE:, 1/4" = 1' -0"bEtAiNu F RL 0 0 EmIft LN A ------ ---------------� y M g OM2 ROOF PITCH 8:12 ROOF PITCH Q• x moo ^ R I PROVIDE ANCHOR BOLTS I ( �' �- I a'• AT 92" O.G. AS PER CODE I W -�• Z TYPICAL I +� Iovive ea. u. +1• D w 110 I <• I AT as•o c. a N o 7 I ;: I 12" DEEP CONCRETE ( I W y T w \ I I FOOTING I '{ I acq 10 kl� 24" WIDE •� I r ( I VALLEY FLASHING TYPICAL r • 5.� 12 FOUNDATION TO BE CONTINUOUS' : 2 1 = 2 I 12 y ( DROP TOP OF FOUNDATION TO ti ( BELOW SLAB AT GARAGE I ? I s I DOOR LOCATIONS Ire I � GEDA ROOFING - r I +; I PRPJECT NO: SHINSLE ON SPACED 0513 STRIP THING ON — I L——J I I DRAWN BY: ROOF RAFTERS I ': Ir I r I TCS :; ;3%::rii%<,; ( I 2� HE KED Y• 24" WIDE I NS VALLEY I •; I I ; I DATE: FLASHIN& ♦ I SEPT. 8, 2006 TYPICAL ,. � .. I I . SCALE: AL 1%4,. = 11 019 SHEET TITLE: 12' s' I GARAGE I + I ---------- TOP of FOUNDATION TO I I ( •` = •r , ".'w., FLOOR p DROP TO BELOW 5LA8 —— OC ■ AT STAIR LOCATION I -_ • I I ( S AI TC I r l I +t I PLANS DOM Ot 12 ROOF PITCH 8:12 ROOF PITCH Dpy,�,l � I m _ I AI E I :• SPOUT SPOUT` MATCH LINE _ MATCH LINE HATCH LINE •i:r:• *t:!,: •'j• :,.r •t•� -••• I E E P,4GE 02 ---- I - I -- ' ---- SEE P GE 02 SEE FASE 5 SEE PAGE 5 �• �* L_ I :� I 4' I6' 4' I ( I I SCALE: 1/4" = 1' -0" SCALE: 1/4" = 1' -0" lea • - Q _ 4�1►i�I1rlf•=�^ Ill _ ���, � _�_ - - • � r/►t 7:z )r� w%� �� _��� ��;�1 3-:i.��d�. .+■fives AP IV IV IV map a-rim ,L","22,SOO -- --/� ,� • ,— monsoon ■■■■ ■■■■ ■■■1 ■ NINE 01100111 ■ "� ■r I � �� �� III ' ■■■■ ■■■■ ■■■■ •••�■■■� ■■■■ ■■■■ _ NONE ■ mmmE m■mE Emmm ■ - ■■ ■■ ■ IIII mill IIII -- NINE IIII on on LE mi mi �lml LE E-� __-. -. • III— � ------__ __ -_— � --_—_.. � ,. . . - - - ---- _ \ ` I I • - - r1I1 WL ■ -�. • t% -.. loss MENINA,�A =• i • • NOMINEE MINION LE • I= - ■ — � ■ ■ � .�4,... 1iE ,i4` - ■ ■■■■ mils' ■ -- mill IIII ■ IIII Immm ■�� --I . _. - --- I - . - . - : . r ■ ON -- - - Lp mill 'A�' r' .y. " s nr . -, t x • Y ; i • 1 � J 0 . I - do low _ Ap IIIIIIIL • _vrrq \�! MEN '•,:- •ram � - •L-�rTiln�= MEN ® r - - - n l�hJl.�r��!■■■ NOON ®� , NOON NOON ® � ■�■ 1111 ■■■■•1 Z�ls, a-ill r ■ NOON E � , � 1111 !\�■■■ 1111 u NOON NOON mill •\ 011 11,m11k,1 ILL- - ALISN 5(7TT0M OF FASCIA -- . _. Sol AROLND ■ - - — - - -- MINE men „■ ■■ �■ ter.. + ■ .� +:.tom. NOON ■ ■ i■ COLUMNS'�i: -- - - 1. NOON - MEC MENEM • ■ ■ � FIRST 1-♦ - , -' ,. :. I.. - • ice/ - - - ap .6 Z. ow- rrrr ♦ ice••/ � % r,=,a7:v:.♦f1_ ♦J' _ .♦♦I ♦- �=-�I � � "711J1` 'ifJ[I1Girrtl _ — 1► ♦ II .Y MWAR _. MEN me O - I -- • i• , i4 'S _- .I" NOON NONE ■r NOON 11,11� ■ ; = ■IIIIII■� NOON NOON ', - •, - C ■■■■. --- --- _ NOON ■ � �■ mill NOON _ ■I ■� ■■■■ i ails Iull I - ' 0513 -�101�01 INS lom MMIM I PROJECT NO: UAW-, LOOM -.. -- ♦i♦ice ♦i- •r - 1TCS — — - - _ llll lllm �� ME MEyl.r;.► r: -. .� L •,_,r,l. mmll ■ mill millSTRAPPED AT TOP lmll r■ EASTSTRIZTURAL 5/5 myyll ON - - Kr-IIZST FLOM SAIl 5LABE allif AND BOTTOM. Mr) WEST HT 0 w z O'-:2y2" -�- 3 PROVIDE RIDGE STRAP PROVIDE RIDGE Q AT EACH R.R. VENT n I r"_�Z CEDAR SHINGLE ROOFING ON WOOD LATH ON NEW ROOF RAFTERS, w/5-1/2" TO WEATHER (TYP) Aw PROVIDE 5/4" WINDOW AND DOOR CASING W DRIPCAP WHERE REQUIRED. ALIGN BOTTOM OF =k ALIGN E30TTOM OF Z FASCIA THROUGH FASCIA THROUGH V OUT HOUSE OUT HOUSE W PROVIDE METAL FLASHING AT ALIGN BOTTOM OF FASCIA O O WALL/ROOF CONNECTIONS. (TYPJ AROUND STRUCTURE (TYP) FLASHING FIRST FLOOR TOP OF PI _ — CIS 6" ALUMINUM RAIN 06 Z• ALIGN BOTTOM OF FGUTTER ON 5/4x8 to Q• FASCIA THROUGH OUT HOUSE ALUMINUM — - — . Y A RAIN GUTTER ON W 5/4x6 FASCIA o -J = m< 2 u. - TOP OF DOORS AND STRUCTURAL FIBERGLASS = W a N o 4 M PROVIDE CEDAR PERFE CTIONS w/6" TOP OF WINDOWS TO COLUMNS W +/- EXPOSURE ON 50# BLD6. FELT ON BE THE SAME STRAPPED AT TOP AND Q o 5/6" PLYWOOD SHEATHING ON 2x6 BOTTOM. I~TYPJ FRAME w/R-la BATTING. (TYPJ to to- FIRST FLOOR TOP OF 4=2) SUBFLOOR L V f4�T I ("J"' lh, Em A S SCALE: 1/4" = 1' -0" PROJECT NO: 0513 DRAWN BY: MCS CHECKED NS DATE: Se tember 8 2006 CALF: 1/4" = 1'-0" SHEET TITLE: SECTION ELEVATION EAST SHEET NO: 3 0 \ 4" THK STONE CHIMNEY TOP 0 / 6" SQUARE STONE SUPPORTS FOR -*2" ` CHIMNEY TOP I I W I _ PROVIDE RIDGE STRAP Z AT EACH R.R. \ 4'-10" 4" THK STONE TRIM STONE VEENER \ CHIMNEY 12 8 8 PROVIDE STEP FLASHING AT ATTIC BASE of CHIMNEY PROVIDE HURRICANE CLIPS AND ALL REQUIRED STRAPPING AS PER 2x10 RR o I6" CODE. 12 2x8 o 1611 2x8 CJ o 16" I' 2x6 0 16" yyyyyYyyyyyyyyyyyyyyyyx ALIGN BOTTOM OF FASCIA LR-50 ALIGN BOTTOM OF FASCIA THROUGH OUT HOUSE / TRAY CEILING BAIT THROUGH OUT HOUSE Z INSUL �,%� 0 / BATT INSULATION W 27 a / GUEST ROOM HALL BATHROOM 1 2 / WOOD FLOORING TILE 1=L / ON PLYWOOD SUBFLOOR SECOND FLOOR TOP OF SUBFLOOR otS Z• 12 n " VIM our=as 1'Sr— FIRST FLOOR TOP OF PLATE N Q Jam• QO � xoe PANWA FASCIA _ THROUGH OUT HOUSE W J � Z ALIGN BOTTOM OF } � THROUGH OUT HOUSE. ALIGN BOTTOM OF FASCIA 5 BATT I I- _ = a Z u.INSUL W gq V W TOP OF DOORS AND TOP OF LIMOLD N&S a FV • N M WINDOWS TO BE THE SAME I SPEC T Q I-• o d coin55 FIBER&LASS -tTMI MAST S 5EDROOM MASTER �` � co- VERIFY WITH ARCHITECT AT TOP AND BOTTOM. try 10) I DISTANCE BETY&-EN TOP OF BATHROOM ( L+-1 'N O DOORS WITH BOTTOM OF FREEZE u- _� I BOARD I w A 2 I I WOOD FLOORING TILE FL 0 �O ON PLYWOOD SUBFLOOR O 1 FIRST FLOOR TOP OF SUBFLOOR FIRST FLOOR TOP OF SUBFLOOR 'z %:;. "•; •: '-• \ TOP OF FOUNDATION SHELF woo BATr Rlo W12X41.O \//\ P/ �\/\ PROJECT NO: 0513 5TL. EM. ��/\/\/\/\/\ \ \ ✓ r. \/ / / / RAWN BY: UT CONTCHECKED BY: 12 ANCHOR NS \/\ \ ;., 5 KEBABS o 32" OG YERT a A ME�I T ?: ATE: 05 RMAR5 0 24" OC HORIZ TYP LJl"1 I V \ o �4• o HORi TYPSCAL " September 8, 2006 10 THK GONG FDN ON 10"x24" \ /\//� GONG. FTG PROVIDE STUCCO FINISH 4'7'DIA COLUMN W/ NEW `. . : 3/8 1 O \\/\ �� BA>�W 6 ODE DAMPROOFIN6 485"x48 A PG FTG BELOW SHEET TITLE: Ix y. E TYP AIJ 4 THK GONG SLAB BUILDING /\//y r�/\/\/\ /\i yV/r 10/0 bXb WWM \ \\ \ �r/\\ \\ \\ \\ \\ \\ \\ \\ SECTION / ` TOP OF BASEMENT SLAB / / SCALE: 3/8" = 1' -0" E A 13 10 O 3 >' w PROVIDE RIDGE STRAP I AT EACH RR PAINTED WOOD TRIM I 1 0 5uo _ / ZxIO ROOF RAFTER AT 160 0/G. PROVIDE HURRICANE CLIPS AND ALL REQUIRED STRAPPING AS PER --- I� CODE. "-ALUMINUM-RAIN GUTTER-0N 5t{x8 -� "•AtUMINUMAeA1N -FASCIA— -ON 12 —12 �N�1L FASCIAS FASCIA _ I6N--5OTTOM-OF-FA9IA I I THROIJ&H-OUT--HOUSE -- _ H OUT-HOUSE PROVIDE-HURRICANE-CLIPS-AND L-REGUIRE17-5TRAPPI NATURAL HaivG COLLAR TIE Ao PILASTER CAPITALTZ X __ \ / SEE SPECS - LOFT I CASED DOLLAR \ '/r/ / TIE ABOVE I g ;�E`I'O ND g \ - CS - - - - - / - GROWN NATURAL \ Z I /I MOULDI 6 WOOD _ O- - - 0 I CAP S S AIR \ y TIMBERSEE ST FRA -G - FLASHING w Ib'-5" / a g,_i■ eq equal ual SPEC 1" TYPICAL a. I PROVIDE-METAL &ABLE 101E BEYOND \ Ib'-II"----------_--_ - -__--- _ - -- _ —I-A5HIN&-AT / - RAOFIN _ NNEGTIONS in - I IDE V ------ - - - - --- - - - Z• Ana• I -I PAINTED TRIM fTYPJ I WOOD STAIRS I •- PROVIDE CEDAR- - - BEHIND - ,J o _ I __SHINGLE SIDING 'NATURAL IM - - - - - - - - r- o< W J• Z- ON ALL WALLS IN - - - I _ - I - - - - - - 2x8 RAFTERS �xb FLOOR 1 TOWER GROWN MO IN6 = W. � � W y OF DOORS AND' WINDOWS TO I I - • g xb�'A�EK"Td s a N � BE AT THE SAME HEIc6HT I V-GROOVE ON a m 2x10 g W. N = M Im_ -- I � GEILINcS-= - - Q I-• � m - -- - JG � N 1-•� - If NITH ARGHI THE — L I Y)Na I - _ - - HERDER IFY WITH ITECT-THE J L/ VISTAE OF - - - ANGE JOP_OF BDO ITH BOTT FREEZE Ap EX = I GAP WITH M-PORCH/ OF N " I I SUNROOM - f --- - - GOD LiiSO - - - - a�, BAR - (N.I.GJ - - B IOULD. I \ �• •\ \ •\ \ \ \ •\ •\ .'i3' '1' •••• a' •t . •. K'• ./''r 1•�'�•••.r ti •� •.i• •} .♦ .i••1'•' '3'• .L�4' /// /// 4 ��' \ \ \ \ \ \ r ::. _ V DE , •, /\/ �� ' \ \ \//\/\//\/\/\� /\ PFOJECT NO: . // / 1 // / / / / // // // // :i:��t WOOD FLOOR ON .3/4 PLYWOOD �TOALL BEARING PO�NTS 6 •� ;' // // // // // �"�bNE OfI/`F° / // \ 0513 �� \ \ \ \ \ \ \ \ \ \ \ SHEATHING ON II 11/8 TJI FLOOR \ \ \ \ \ ` �� \ \ \ \ \\/\\/ /\\/ /\\/\\ \\� %»:: JOISTS AT I6" 0/G:. w/R-la BATTING OF TJI F.J. (TYPa ///// /� / / / / / / / / '..,t / / / / / `., . ;. / / / / / � �\ /\, \ �/ DRAWN BY: UT // ' 4 STL. COLUMN W/ NEw / NS 2 48 x48"xl b PG FT& BELOW , 3 PROVIDE GoNCRET'E BLoGKS (Bxlb) \� '•ti» 10" THICK GONG. WALL ON IO"DEEP BASEMENT ::.;; \/\/\/\/ Se tember 8, 2006 STARTING AT TOP OF FOOTING TO \\ \\ \\,^! :; x 24" WIDE GONG. FOOTING :'•.:; \\ \\ \\ I SCALE: UDER5IDE OF GRADE BEAM /� :�:i;' REINFORCED WO) #4 REBAR. (SEE 3/8„„ = 1„ - O SECTION "A' FO}R ADDITIONAL INFO) \ \ \ \ SHEET TITLE: FOUNDATION BEHIND // /� '`'•t /////� /// 4" CONC. SLAB ml 6xb, 10/10 W .M. `•�'• BUILDING I \\ A .W SECTION / •/• / / /•• / ,/ /• / / •/• / •/ / / \• ,•••• \/ B vv 4" bxb, 10/10 W.W.M.. PROVIDE 5AW ;: CUT CONTROL JOINTS AT 20 \ \ \ \ \ r ": \ \\\\\ \\\ \\\\\\ \\\\\\ \\\ INTERVALS. ('TYP) "t B E3 U I L I 'I'VE 'pm Imc u '�lmwj um SCALE: 3/8" = V -0" WEATHER VANE 2x4 RAFTERS 2x4 HEADER AA sO PROVIDE HURRICANE CLIPS AND Ix4 PRE-PREMMM >_ ALL REGUIRED STRAPIN& FINGER JOINED FA501A PAINTED AS PER EPECS. W Ix6 PRE-PRIMMED FINGER n JOINED SOFFIT B . PAINTED AS PER SPECS. CEDAR SHINGLES ON 15* BLD6. PAPER ON 5/5" PL YVOOD 5HEATHIN6 ON 2x4 FRAME 12 WMI 8 CANE STRAP ER S RAFT / RAFTM 2x10 GJ PROVIDE RIDGE &ARA&E TOP OF AT EACH R.R. (5)2xIO ATTIC FLR PLATE 2x6 GJ S S � PROVIDE HURRICANE CLIPS AND I2 ALL REOUIRED 5TRAPFING A5 PER CODE. 27 ■ 4 12 12 d) V HURRICANE CLIPS YVALL �. •� DECKING UN I I JHF D 2XIOJOIS FLOOR STUD /BOX BEAM /RAFTER +\�Q' f - - - - - - 'y R-50 BATT INSUL BA17 INSULATION O ATTIC W 6" ALUMINUM RAIN • GARAGE TOP (Sr- PLATE FIRST FLOOR TOP OF PLATE Q. GUTTER ON Ix6 FASCIA -i \- ALIGN BOTTOM OF FASCIA L PROVIDE TYPE "X" GYP. THROUGH BATTING THROUGH OUT HOUSE WOOD STAIRS 2x5 G.J. ® 16" BD. ALL SURFACES IN BEHIND -I O/G. GARAGE. — G PROVIDE HURRIIGANE GLI AND L MO ING 5EE ALL REOUIRED STRAPPIN AS PER L verify verify ,ODE, L � � 0 I otS Z• ■ coQ• " R-la BATT LAUNDRY - T r GAi4 GE IN5UL (TYP) - ROOM a& O T } -la BATT W -j• _ lz i INSUL (TYP) W• c, 2 U. 2 ,t�JO 2 a " off 4" THICK CONCRETE SLAB "GO YV/ 24"x24"xl2" O TILE O V 0 In g W• N PITCHED TO DRAIN REINFORCED PG FTv BELOYV— PLYWOOD 1 SUBFLooR 1 Q ~. re 6x6, 10/10 W.W.M.. PROVIDE �— — — I 5A GUT5 AT 20 FT. INTERVALS. — TOP OF FOUNDATION FIRST FLOOR TOP OF SUBFLOOR N W •r ,.. :• �. .• ..••,; , . .. .•. .. :,• �' OP OF FOUNDATION \ \ \ �� 05 REBAR (TYP) GONT ------ ' TOP OF SHELF AT FOUNDATION \\ jt /\/ �: R-la BATT / /\ VIDE "XI2 ANCHOR INSULATION\ (2) #B FREBAR (TYPJ/ / // :v i.+�• / +; . . LT5 ® 4-O O.G. /\\/\\ •r \\/\\ i\\/ \ \ \ \ \ \\/ 4 / �,;Y WOOD STAIR A : ••'• \/\ ,�,' � BOL'T5 m0 "-0" O.G. %;" RAILLIN6 � �r �• � t�. ••ry •. . ■ 10"THK_ CONCRETE \/\\/\\ :•i:. _:' /\\/\ REIIFOfRID W/WIN 5 \� 20' FRGOM TOP OF x�4"wRDe coNG. PROJECT NO: REINFORCED W/fs) /\//\ i f'. : /\ 0513 4 REBARLIT '. RAWN BY: BASEMENTECTM BY: NS 4 ;. ;� ..•., TOP OF BASENtENT SLAB September 8, 2006 SHEET TITLE: BUILDING c I IOU M % I %j I u MWILD11 1 11 " u " I L"'[1), 1 Ift 0 03 So` wRE 0%w "1 00% SCALE: 3/8" = 1' -0" SCALE: 3/8" = 1' -0" SECTION PROVIDE RIDGE PAINTED CASED IN BEAM VENT 0 ffim : W / mom Z / SHINGLES TO FLARE SLOPED / \ SLOPED OVER GROWN MOULDING 5 CEILIN& / \ CEILING TOP OF FRAME m WINDOW CASED COLLAR TIES (rm) a SHINGLES TO FLARE 0 \ \ = OVER GROWN MOULDING. n NATURAL WOOD TRIMED j / CASED bAMBREL PURLIN BOTTOM OF COLLAR TIE/STRUCTURAL PURLINS PILASTER GAPI AL ` a RMER SEE SPECS \ \ DO DORMER TYPICAL DOOR GA51N6 \ GROWN MOULDINb \ AL IL IL LO T O o d d WOOD RAILLING P11 11 u u — —I / / bAMBREL FRAME BEYOND A \ NATURAL F FLASHING TYP I ON PL FLLOOOOO R PROVIDE FLASHING AT / / Z IWINDOW/ROOF INTERSECTION IL 0 6 / _ — I ry STANDING SEAM. L.G.G. ROOF Q \ 2 W O.5 ND FLOOR TOP OF SUBFLOOR I 12 a. / J FI T FLOOR TOP OF PLATE ol CRONN ALIGN BOTTOM OF I=ASCIA I TOP OF DOORS AND MOULDING PANTED 'TRIM THROUGH OUT HOUSE � I W4N�IEO�I6F0 BE AT THE ,4, I n PROVVDE R-30 I I ( PAINTED Q I BATTING. I CASED OPENING I IIll CELII�G I I � z• 12" VIA STRUCTURAL FIBERGLASS I COLUMNS 5TRAPFM vkRiFy WITH ARCHITECT THE AT TOP AND BOTTOM. (TYPJ D15TANGE BETNEEN TOP OF Q a ` , _ J o ^ ARD WITH BOTTOM OF FREEZE " BAR FOYF—R I GOY EP I L I VI NG R00M AREA NT = a ? LL La in 3 \ / WOOD FLOORING ON 90# BLDb. CASED COVERED ERED PAPER ON 9/4" PLYW00P OPENING I a In N 1 I I z � � DECKINS GLUM AND NAILED 1 4 W• N n IFORGH � TO II-'7/8" TJI F.J. a Ib" O.G. pd., I I 1 Q F-• " '°I BASE MOULDING BASE MOLDING BRASS BAR GONG PIERS 18" VIA 96" ( co �• BELOW &RADE RAIL. (N.LcJ I .. FIRST FLOOR TOP OF SUBFLOOR . 3• `' ,,"• Al ' 'f., :. , , -•:: +i •" ~ TOP OF SHELF AT FOUNDATION /\// I PROIVDE R-ICI �4 A A STL. 5M. BATTING. 5TL. 5M. 5TL. BM. N 48 x48 x l8 G P FT(9 BELOW /\\/ \�\\/\\/\\� BSM �1T 4" THICK GONG. SLAB REINFORCED PROJECT NO: 0513 RO W.W.M.. PROVIDE SAw RAWN BY: IO THK GONG FDN ON 10 x24 GUT CONTROL JOINTS AT 20 2'X2'XI' GONG. FT&. W/ 12" / CONC. FTG PROVIDE STUCCO INTERVALS. (TYP) UT VIA,. 5ON07UE E PEDESTAL TO /\//\/ I �:;� FINISH ABOVE GRADE AND '•. \ \ \ \ \ \ \ GRADE REINFORCED �\ \\ y:;: DAMPROOFING BELOW GRADE ; CHECKED BY. Y03)#5 REBAR EACH WAY. / TYP / / / / / / / ` N$ PROVIDE (4)#5 REBAR FROM ATE: FTC=. THRU PEDESTAL TO /\/ ' .}•" /\/\/\/� \/\/\/ GRADE. FOOTING TO BEAR ON / / TOP OF BASEMENT SLAB September 8, 2006 UNDIISTURBED EARTH. `' „ J \/\� .f ., :li r f�. 'f �' • .T: '..;}' r• i• 1 !'!••fit: •..V•Y =.. :f' , , .• 1: :• fy :y _ 2., �. �. r. \ \ /\\/ ;..•';: / / / / /• / / / / / / / / / / / �/ / / `/ / / r/ / •/ / / / / ••:r.;',, �/ / \/\/\\ SCALE: _ IN\ \ \ \ \ \ \ \ \ SHEET TITLE: BUILDING SECTION "Ell o u I L D I N G' S 'E Col'i N SCALE: 3/8" = V -0" iVRYYiELL FOR \ BUILDING ROOF TF GARAGE GUTTERS \\ \ LAWN �L \\ j LAWN GRAVEL = ST NE \ PARKING AREA• d1 D� \ PA RS N_ " / O GSL W/ I \ �\ :O' DID 8' DID I 1��■ X6 WWM _IG I��„ \ 20 _tO \ / S 12"x1i2"x2" THK LAWN STONE EDGING 1 AG ON GONG SLAB 1 • _ I Li 2 Ld ii +IC1.2 EXISTING AGGE550R1r `fiy +iq.2 I STRUCTURE TO B1= •REMOVED 1 NEW UNDERGROUND— +I — — — \ S 1 LLJ PROPANE TANK FOR POOL _ D yN 1 I Z EQUIPMENT AND BBQ (— 1 8' D I A \ 8' HT II \ -:'�DRYWELL FOR BUILDINGu ROOF G I +Iq.2 I I x2" THK I \ I STONE EDG1NG I r ON GONG SLAB 6" WIIDE 3 I/2" HIGH MAHOGANY OVAL HANDRAIL MAHOGANY OVAL HANDRAIL 6" WIDE 3 I/2" HIGH AC \ I I I • LAWN STAB LESS STEEL PLATE WELDED TO = \ I I I P05T'4ND SCREWED TO HANDRAIL 3" THICK BLUSTONE COPING BEYOND \ 2" DIJA STAINLESS STEEL POST POLISHED FINISH = � - _ _ _ _ WITH 2 1/2" OVERHANG TYPICAL \ _ I PL I 5/4" MIA STAINLESS STEEL RAIL ALUM PLATE WELDED TO BALUSTERS AND \I POLISHED FINISH WELDED TO POSTS m = 50REWED TO HANDRAIL PAINTED BLACK I , 1/2 1;�A STAINLESS STEEL VERTICAL - 1 1/2 SQUARE ALUM BALUSTER PAINTED COOKING ISLAND (1I'x3'x5' HT): I " STONE PA E -0N " \'Z� W ILS@ TO 11 POS OL15HED FINISH m _ BLACK AT 4" Or. I STONE VENEER WALLS W/ GMUHK AB b �- - CENTERLINE POOL I STRUCTURE, SOLID STONE _ -I s"x8"?xQ" STAINLESS STEEL ANGLE WELDED TO POSTS i 1/2 SQUARE P05T5/BALU5TER5 AT 4FT OG MIN COUNTERTOP W/ PREFAB BBQ IG ,_ 1�.,75 �n WITH IEQCPANSION BOLTS (4) 1/2" x 6" INTO CONCRETE EQUIPMENT UNITS BUILT INTO ISLAND, I " �er oot `n BLUES'ONE PAVING = EXPANSION BOLTS �DED TO POSTS WITH LOCATION PROVIDE ELECTRIC AND GAS _ O /2 x 6 INTO CONCRETE HOOKUPS I BLUESTONE CAPSTONE ON MORTAR _ - - EXISTING I N SETTING BED ON CONCRE TE STRUCTURE ORNAMENTAL METAL I - 3 .. STONE VEN EER MORTAR ON CO NCRETE TE WAL L I NG 48 HT THE E 27 I P I CONCRETE RETAINING ��''GCOC7ICING.= L -1 WALL ISLAND.? I Vv 4" GRADE V CHAIN LINK FENCE I I I PL Z .. I z (2) GATES: 4 "X48 LAWN 42 X48, HT Tf SCALE:--CURVED RAILING NTS 3 RNAMENTAL METAL RAILING V SCALE:NTS I � SELF CLOSING W I -L-OSIN --4 _J a 4 LATCHING TGHI G - - I — — ORNAMENTAL METAL RAILING EXISTING TREES \\ — 48" HT 27 3I GPO�/E�F�ED +iq 3 +1a.2 TO BE REMOVED OO TERRAC \ PROPOSED 5 BEDROOM RESIDENCE \ P ER TOP _ \\ TO -O P RAIL - 4 i - LAWN DRYWELL FOR POOL \ L 3.0 WATER BACK A5H + .23 °� Z.W W I .3 0 GA T R C +18.83 � a• " � 11 2 O T -- I a CHAIN LINK FENCE y ` - `p E P VERS D & >Q 1 8 1 I I ¢ GA "X48" GOl LG LAB W-10 6 LO P RGH W -J. a I.:8 n • \ 1 HT W_ O w > o G GLOS 1 � TYPI a � � e \\ / LATG� IN �. W. N = cq \\ PL ,_ m "x*:'72"x2" THK 2" 12" m 5TO,NE EDGING ' DN (GONG SLAB � GRADE 2" THK BLUESTONE �- COPING 26' L-T- BLUESTONEAID TIGHT LL t L � 7 TOOLED MASONRY L ,� TOP �D JOINTS N C ' Q� PROVID CURVED 55 RAIL LAWN � s��� � HAND ILS INTO POOL �_, +23.0 REINFORCED GONG RETAINING Y � WALL W/ 4# 12" HORIZ. AND "'' • � � �'BOTH 51 E OF STEPS 1 4#4 ® 12 VE T. ORNAMENTALTr ,� METAL LING // 18.2 \\ PROV I E WAUNGH I N POOL 48 HT 27 / 'e - \ Y, FOUND TION'FQR ( TER E SUPPOIp-� , +18.�5 1 1 '4" g Ot SURR NDING POOL T1'P 8 ST D PR JECT NO: �� �� '; \ 0513 12 x-12 x2 THK STONE PIERS 9D 5CQ AT 8 HT, DRAWN BY: +I"T'O HSTONE - -- - STONE P OL COPING BASE W/ 4" Tm I'-o" , COPING W/2" OVERHAANb DRYWELL FOR UT _ EQUAL ALL 51DE5%A7 BUILDING ROOF CHECKED BY: GUTTED-s •' v ;> REINFORCED GONG NS FOOTING W/ DATE: \ / <rr 4 ® 12" O.G. AND 5#4 6'-b" 2'-b" i'-4" September 8 2006 ' °I POOL- \ -- � CONT. Ps-c SCALE: 3116"= 1'-0" LAWN TOP (JRAIL � � /8SHEET TITLE: +22.25 LOW STONE VENEER WALL 18' ENLARGED HOSE BIB POOL ORNAMENTAL \ (2� GATES: PL r SW1MOUT PL METAL RAILING `� EXISTING Tfi�EES TO SITE PLAN 48" HT 3 HAY BALES RM�t I N TYP \ 42 X48 HT SELF CLOSING Iq.�+ LATCHING, GHAI LINK - x/c�� 2 5 O NE A 4' 7Pf k x; N 2- SLAB 0- \aZO \ , SHEET NO: Li C OP STONE PIERS BO" SQ AT 3 OP O� $LVFF • +I'7.20 BASE W/ 4" THK STONE 27 17.25+ ,o R IL COPING W/2" OVERHANG 91 EQUAL ALL SIDES +Icf'20 8" THK CONCRETE RETAINING WALL EXISTING \ 0/00F MY 55 CURVED RAILING W/ 4" THK STONE VENEER ABOVE - ALIGN CORNER OR PIER LAWN 32WALL 24 STONE 27 BELOW GRADE "�GONc FTG B6" LU WITH FACE OF WALL eF- 11"Mo A L SET 27